Y26-604_Drawings-_Plans.pdf
PDF 6 MB Posted
- Solicitation number
- Y26-604
- Issued by
- Orange County, Orlando City, Florida
About this file
Summary of EWRF Electrical and Mechanical Upgrades Project Drawings and Plans
This document is a comprehensive set of construction drawings and plans prepared by Orange County, Florida's Utilities Department for the Eastern Water Reclamation Facility (EWRF) Electrical and Fuel Storage Improvements project (OCU File No. 97390, CIP Funding Code 1538-0029). The project encompasses electrical and mechanical upgrades including neutral grounding resistor replacement, 15 kV switchgear modifications, three diesel generator system replacements with EPA/RICE NESHAP-compliant units, disconnects, cabinets and boxes, instrumentation and controls, wire and conduit installation, demolition and relocation services, concrete equipment pads, and mobilization/demobilization. The sealed bid submittal is scheduled for October 2025 via the OpenGov e-Procurement Platform, with a non-mandatory Pre-Bid Conference scheduled for April 2, 2026 at 2:00 pm at the EWRF location (1621 S Alafaya Trail, Orlando, FL 32828), and the question submission deadline is April 8, 2026 at 5:00 pm EST. The bid due date is April 23, 2026 at 4:00 pm EST. All work shall be substantially completed within 365 calendar days from the Notice to Proceed. The drawings were prepared by William C. Nelson, P.E. (Florida P.E. No. 42017) and Ferdinand A. Vasquez, P.E. (Florida Registration #69248).
The project includes detailed structural, electrical, and utility coordination requirements. Contractors must verify all existing conditions prior to procurement and construction, coordinate with multiple utility providers including Duke Energy, TECO Peoples Gas, Commcast Communications, Level 3 Communications, and Bright House Networks, and provide temporary scaffolding, bracing, and protective measures during demolition and construction. Key structural criteria require contractors to ensure stability and safety of the structure during erection, implement appropriate temporary bracing and shoring, and comply with the 2023 Florida Building Code and ASCE 7-22 standards. Electrical specifications require compliance with 12.47 kV system requirements and installation of new metal-clad switchgear sections with vacuum circuit breakers. The contractor is responsible for all costs related to utility location verification, infrastructure protection, damage repairs, and any sanitary sewer overflows occurring during construction. Award will be made to the lowest responsive and responsible respondent on an all-or-none basis, with respondents required to hold valid Florida Electrical Contractor or General Contractor licenses and demonstrate prior experience with generator switchgear and controls installations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BOARD OF COUNTY COMMISSIONERS
JERRY L. DEMMINGS
ORANGE COUNTY MAYOR
NICOLE H. WILSON
DISTRICT 1
CHRISTINE MOORE
DISTRICT 2
MAYRA URIBE
DISTRICT 3
MARIBEL GOMEZ CORDERO
DISTRICT 4
EMILY BONILLA
DISTRICT 5
VICTORIA SIPLIN
DISTRICT 6
BYRON W. BROOKS, AICP
COUNTY ADMINISTRATOR
ED TORRES, M.S., P.E., LEED AP
DIRECTOR ORANGE COUNTY UTILITIES DEPARTMENT
OCU FILE NO.: 97390
CIP FUNDING CODE:
1538-0029
ATTENTION IS DIRECTED TO THE FACT THAT THESE
PLANS MAY HAVE BEEN REDUCED IN SIZE BY
REPRODUCTION. THIS MUST BE CONSIDERED WHEN
OBTAINING SCALED DATA. DIMENSION
INFORMATION SHOULD NOT BE OBTAINED BY
SCALING THE PLANS.
ORANGE COUNTY UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD
ORLANDO, FLORIDA 32825
(407) 254-9900
EWRF ELECTRICAL AND FUEL STORAGE IMPROVEMENTS
BID SUBMITTAL
OCTOBER 2025
AutoCAD SHX Text This document has been electronically signed and sealed by Ferdinand A. Vasquez, P.E. Printed copies of this document are not considered signed and sealed. The signature must be verified on the electronic document.
AutoCAD SHX Text No. 69248
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
FERDINAND VASQUEZ, P.E.
AutoCAD SHX Text
FLORIDA REGISTRATION #69248
SCALE:
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
LOCATION MAP
SCALE:
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
SCALE:
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
LOCATES SUNSHINE ONE CALL----------------------------------- 800-432-4770
ELECTRIC DUKE ENERGY-------------------------------------------- 407-398-6670
GAS TECO PEOPLES GAS------------------------------------ 407-420-6609
FIBER OPTIC COMMCAST COMMUNICATIONS--------------------- 407-312-5944
FIBER OPTIC LEVEL 3 COMMUNICATIONS--------------------------- 720-888-2061
PHONE BRIGHT HOUSE NETWORKS-------------------------- 407-532-8509, 407-532-8520
UTILITIES ORANGE COUNTY DISPATCH ------------------------ 407-254-9798 (24-HR ASSISTANCE)
EMERGENCY NUMBERS
PHONE CENTURY LINK--------------------------------------------- 407-815-5344, 407-557-6766 PHONE MCI------------------------------------------------------------- 972-729-6016
PHONE SMART CITY TELECOM---------------------------------- 407-828-6648
PHONE TW TELECOM------------------------------------------------ 407-215-6895
GENERAL NOTES
1. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN EXCAVATING IN PROXIMITY
OF INCLUDING, BUT NOT LIMITED TO; WATER MAINS, WASTEWATER FORCE MAINS, GRAVITY
MAINS, RECLAIMED WATER MAINS, ELECTRIC, GAS, CABLE TV, TELECOMMUNICATIONS,
STORM WATER, FIBER OPTIC AND OTHER UNDERGROUND FACILITIES. MAIN LOCATIONS
SHOWN ON PLANS MAY NOT BE EXACT. THE CONTRACTOR IS RESPONSIBLE FOR FIELD
VERIFYING EXISTING UTILITY LOCATIONS.
2. SHOULD A PIPE EMERGENCY OCCUR, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE
OCU DISPATCH OPERATOR (407-836-2777) AND THE OCU INSPECTOR.
3. THE CONTRACTOR SHALL NOTIFY THE OCU CONSTRUCTION INSPECTION SECTION, FIELD
SERVICES DIVISION AT LEAST 10 CALENDAR DAYS PRIOR TO COMMENCEMENT OF THE
CONSTRUCTION PROJECT BY CALLING (407) 254-9798.
4. THE CONTRACTOR SHALL NOTIFY THE OCU CONSTRUCTION INSPECTOR IN ACCORDANCE
WITH TABLE 4110-1 "UTILITIES' SCHEDULE OF NOTIFICATIONS IN THIS MANUAL.
5. THE MATERIALS, PRODUCTS, AND CONSTRUCTION OF ALL UTILITIES CONNECTING TO THE
OCU SYSTEM SHALL BE IN CONFORMANCE WITH THE STANDARDS, AND CONSTRUCTION
SPECIFICATIONS, AND APPENDIX D IN THIS MANUAL.
6. ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO; WATER MAINS, FORCE MAINS, RECLAIMED WATER MAIN, SANITARY GRAVITY PIPES, STORM WATER PIPES, ELECTRIC, TELEPHONE, GAS, CABLE TV AND OTHER UTILITY FACILITIES WITHIN THE LIMITS OF THE
PROJECT WILL BE SUPPORTED AND PROTECTED AGAINST DAMAGE DURING CONSTRUCTION.
7. THE CONTRACTOR SHALL ADJUST ALL EXISTING OCU MAINS AND FACILITIES IN CONFLICT
WITH NEW GRADE, NEW OR ALTERED ROADWAYS, SIDEWALKS, DRIVEWAYS, CURBS, OR
STORM WATER IMPROVEMENTS. OCU FACILITIES TO BE ADJUSTED INCLUDE, BUT ARE NOT
LIMITED TO; PIPELINES, PUMP STATIONS, VALVE BOXES, AIR RELEASE VALVES, FIRE
HYDRANTS, MANHOLE COVERS, AND METERS. ALL ADJUSTMENTS SHALL BE MADE TO
CURRENT STANDARDS.
8. ONLY OCU PERSONNEL SHALL OPERATE EXISTING OCU WATER, WASTEWATER, AND
RECLAIMED WATER VALVES. THE CONTRACTOR IS RESPONSIBLE FOR OPERATING ANY
NEWLY INSTALLED VALVE THAT HAS NOT BEEN CLEARED FOR USAGE BY FDEP AND OCU. THE
CONTRACTOR SHALL COORDINATE VALVE OPERATION WITH THE OCU INSPECTOR. FOR
OPERATION OF MAINS NOT OWNED BY OCU, IT IS THE CONTRACTOR'S RESPONSIBILITY TO
COORDINATE WITH THE APPROPRIATE UTILITY REPRESENTATIVE.
9. CONSTRUCTION ACTIVITIES SHALL NOT CAUSE INTERRUPTIONS IN WATER, WASTEWATER, OR
RECLAIMED WATER SERVICE. THE CONTRACTOR SHALL COORDINATE PRE-APPROVED
INTERRUPTIONS OF SERVICE WITH THE OCU INSPECTOR 7 WORKING DAYS IN ADVANCE AND
WRITTEN NOTICE SHALL BE GIVEN TO AFFECTED CUSTOMERS AT LEAST 4 WORKING DAYS IN
ADVANCE.
10.THE CONTRACTOR SHALL PROVIDE FOR BYPASSING AND / OR HAULING OF WASTEWATER
DURING APPROVED INTERRUPTIONS OF WASTEWATER FLOWS AND CONNECTIONS. THE
CONTRACTOR SHALL SUBMIT A BYPASS OR HAUL PLAN, REVIEWED AND APPROVED BY A
PROFESSIONAL ENGINEER TO OCU DEVELOPMENT ENGINEERING AND TO THE INSPECTOR
FOR APPROVAL PRIOR TO IMPLEMENTATION BY CONTRACTOR.
11. ALL VALVES INSTALLED AS PART OF THIS CONSTRUCTION PROJECT SHALL REMAIN CLOSED
DURING CONSTRUCTION. KEEP VALVES ON ALL WET TAPS CLOSED UNTIL CLEARED BY FDEP.
DO NOT CONNECT NEWLY CONSTRUCTED WATER MAINS TO ANY EXISTING WATER MAINS
UNLESS CLEARED BY FDEP AND OCU.
12.THE CONTRACTOR SHALL PROVIDE A JUMPER ASSEMBLY WITH AN APPROVED BACKFLOW
PREVENTER FOR MAKING TEMPORARY CONNECTIONS TO AN EXISTING POTABLE WATER
SOURCE IN ORDER TO CHLORINATE AND FLUSH NEW WATER MAINS WITH POTABLE WATER.
ANY TEMPORARY POTABLE WATER CONNECTIONS TO RECLAIMED WATER OR FORCE MAIN
SHALL ALSO BE EQUIPPED WITH AN APPROVED BACKFLOW PREVENTER.
13.FOR PVC PIPE, NO JOINT DEFLECTION OR PIPE BENDING IS ALLOWED. ALIGNMENT CHANGE
SHALL BE MADE ONLY WITH FITTINGS.
14.FOR DIP PIPE, LONG RADIUS CURVES, EITHER HORIZONTAL OR VERTICAL, MAY BE INSTALLED
WITH STANDARD PIPE BY DEFLECTIONS AT THE JOINTS. MAXIMUM DEFLECTIONS AT PIPE
JOINTS, FITTINGS AND LAYING RADIUS FOR THE VARIOUS PIPE LENGTHS SHALL NOT EXCEED
75 PERCENT OF THE PIPE MANUFACTURER'S RECOMMENDATION.
15.FOR APPROVED PVC OR HDPE PIPE USED IN A HORIZONTAL DIRECTIONAL DRILL
INSTALLATION, THE CURVATURE AND/OR DEFLECTION SHALL NOT EXCEED THE PARAMETERS
ESTABLISHED IN THIS MANUAL.
16. ALL DAMAGE TO ORANGE COUNTY INFRASTRUCTURE, PIPELINES, AND ASSETS SHALL BE
REPAIRED IMMEDIATELY BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE WITH AN
APPROVED METHOD BY THE COUNTY. IF THE REPAIR IS NOT PERFORMED IN A TIMELY
MANNER, AS DETERMINED BY THE ORANGE COUNTY UTILITY INSPECTOR, ORANGE COUNTY
MAY PERFORM REPAIRS AND THE CONTRACTOR WILL BE CHARGED FOR ALL EXPENSES
ASSOCIATED WITH THE REPAIR.
17.THE CONTRACTOR SHALL BE LIABLE FOR ANY AND ALL SANITARY SEWER OVERFLOWS (SSO)
ASSOCIATED WITH THE WORK, REGARDLESS OF FAULT. THE CONTRACTOR WILL BE
ASSESSED PENALTIES FOR ANY AND EACH SSO AS SPECIFIED IN SECTION 3110, GENERAL
CONSTRUCTION REQUIREMENTS.
STRUCTURAL GENERAL NOTES
GENERAL STRUCTURAL CRITERIA
1. STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE
ONCE IN SERVICE. NO CONSIDERATION FOR STABILITY AND SHORING
IS ASSUMED BY THE ENGINEER DURING THE BUILDING PROCESS. IT
SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THE
STABILITY AND SAFETY OF THE STRUCTURE AND ITS COMPONENTS BY
DETERMINING AND IMPLEMENTING ERECTION PROCEDURES AND
SEQUENCE OF CONSTRUCTION. THIS INCLUDES TEMPORARY
BRACING AND SHORING AS WELL AS SOIL STABILIZATION AND
PROTECTIVE MEASURES FOR ADJACENT EXISTING CONSTRUCTION.
2. STRUCTURAL DRAWINGS SHALL BE UTILIZED CONCURRENTLY WITH
DRAWINGS OF OTHER DISCIPLINES TO CONSULT INFORMATION NOT
EXPLICITLY INDICATED ON STRUCTURAL DRAWINGS.
3. CONTRACTOR SHALL VERIFY DIMENSIONS AND SITE CONDITIONS
PRIOR TO PROCEEDING WITH PROCUREMENT OF MATERIALS AND
LABOR, FABRICATION, AND CONSTRUCTION WORK. WHERE
DISCREPANCIES EXIST, NOTIFY ENGINEER OF SUCH DISCREPANCIES
IN WRITING VIA A REQUEST FOR INFORMATION / INTERPRETATION
(RFI) BEFORE PROCEEDING WITH THE WORK IN THE AFFECTED AREA
IN QUESTION.
4. NO STRUCTURAL MEMBER OR COMPONENT SHALL BE CUT, NOTCHED,
OR OTHERWISE ALTERED UNLESS APPROVED IN WRITING BY
STRUCTURAL ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR ANY AND ALL COSTS INCURRED BY STRUCTURAL ENGINEER FOR
REVIEW OF SUCH DEVIATIONS AND IMPLEMENTATION OF
APPROPRIATE SOLUTIONS.
5. PRIOR TO COMMENCING WORK, THE GENERAL CONTRACTOR SHALL
BE RESPONSIBLE FOR REVIEWING AND COORDINATING WITH THE
SUB-CONTRACTORS WORK INDICATED ON STRUCTURAL DRAWINGS
WITH DRAWINGS OF OTHER DISCIPLINES.
6. THE STRUCTURAL DRAWINGS ARE REPRESENTATIVE OF THE
FINISHED STRUCTURE. THE STRUCTURAL ENGINEER SHALL NOT BE IN
RESPONSIBLE CHARGE AND CONTROL OF CONSTRUCTION MEANS,
METHODS, PROCEDURES AND CONSTRUCTION TECHNIQUES, AND
JOBSITE SAFETY. THIS SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR.
7. THE STRUCTURAL ENGINEER SHALL NOT BE CONSTRUED AS HAVING
CONTROL, CHARGE, AND RESPONSIBILITY FOR THE ACTS AND
OMISSIONS AND FOR FAILURE OF THE CONTRACTOR, SUB-
CONTRACTOR, AND OTHER PERSONS PERFORMING THE WORK TO
CARRY OUT SUCH WORK IN ACCORDANCE WITH THE STRUCTURAL
DRAWINGS AND COLLECTIVE CONTRACT DOCUMENTS.
8. PERIODIC SITE OBSERVATION BY THE STRUCTURAL ENGINEER AND
HIS / HER REPRESENTATIVES IS SOLELY FOR THE PURPOSE OF
DETERMINING IF THE WORK OF THE CONTRACTOR IS PROCEEDING IN
GENERAL ACCORDANCE WITH THE STRUCTURAL DRAWINGS AND
SPECIFICATIONS. THIS LIMITED SITE OBSERVATION SHALL NOT BE
CONSTRUED AS AN INSPECTION, EXHAUSTIVE, OR CONTINUOUS
OBSERVATION TO VERIFY THE QUALITY AND QUANTITY OF THE WORK.
DESIGN CRITERIA
1. STRUCTURAL WORK SHALL BE IN ACCORDANCE WITH:
FLORIDA BUILDING CODE 2023 EDITION 8 AS ADOPTED AND
SUPPLEMENTED BY LOCAL REGULATIONS AND ASCE 7-22 MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES.
2. REFER TO DRAWINGS OF OTHER DISCIPLINES FOR DIMENSIONS AND
ELEVATIONS NOT INDICATED ON STRUCTURAL DRAWINGS. NOTIFY
ENGINEER OF DISCREPANCIES PRIOR TO EXECUTION OF WORK.
3. NO PROVISIONS HAVE BEEN MADE FOR FUTURE VERTICAL AND/OR
HORIZONTAL ADDITIONS, MODIFICATIONS, AND/OR EXPANSIONS
EXCEPT AS SHOWN ON THE STRUCTURAL DRAWINGS.
EXISTING STRUCTURE
1. INFORMATION SHOWN FOR THE EXISTING STRUCTURE ON THESE
DRAWINGS WAS TAKEN FROM THE FOLLOWING:
PREPARED BY: AECOM
ENTITLED: ORANGE COUNTY - EWRF - PHASE IV-C IMPROVMENTS
MAIN ELECTRICAL/BLOWER BUILDING
DATE: 02/28/09
2. WORK SHOWN ON THESE DRAWINGS ASSUMES THAT THE ORIGINAL
CONSTRUCTION WAS PERFORMED IN ACCORDANCE WITH THE ABOVE
INDICATED ORIGINAL DRAWINGS INCLUDING (BUT NOT LIMITED TO)
DIMENSIONS, ELEVATIONS, MEMBER SIZES, MATERIALS, DETAILS, ETC.
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE CONDITIONS RELATING TO THE EXISTING STRUCTURE AND TO
NOTIFY THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES OR
CONFLICTS.
DEMOLITION NOTES
1. THE CONTRACTOR IS REQUIRED TO PROVIDE ALL TEMPORARY
SCAFFOLDING, PLATFORMS, BARRICADES, RAILINGS, SCREENING,
ETC. NECESSARY TO PROTECT EXISTING FACILITIES, STRUCTURES
AND THE PUBLIC DURING DEMOLITION AND ERECTION OF THE NEW
CONSTRUCTION, AS WELL AS FOR JOB SAFETY. JOB SAFETY,
CONSTRUCTION AND DEMOLITION PROCEDURES ARE THE SOLE
RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS
REQUIRED TO TAKE ALL PRECAUTIONS TO MINIMIZE VIBRATION,
NOISE, DUST AND DEBRIS IN ALL AREAS ADJACENT TO AREAS OF
DEMOLITION.
2. THE CONTRACTOR IS REQUIRED TO COORDINATE WITH THE OWNER
FOR THE TEMPORARY SUSPENSION OF USE OF ANY FACILITY OR
PORTION THEREOF, AND THE ASSOCIATED BARRICADING
REQUIREMENTS WITHIN A MINIMUM OF 7 DAYS PRIOR TO
COMMENCING WORK.
3. THE CONTRACTOR IS REQUIRED TO PERFORM HIS WORK IN A
MANNER, WHICH WILL NOT CONFLICT WITH ANY OPERATION, WHICH
IS TO REMAIN FUNCTIONAL DURING THE COURSE OF THE PROJECT,
UNTIL SUCH OPERATION IS SCHEDULED TO BE SHUT DOWN.
4. THE CONTRACTOR IS REQUIRED TO COORDINATE WITH OWNER FOR
THE TEMPORARY SUSPENSION OF USE OF ANY UTILITY SYSTEM, A
MINIMUM OF 3 DAYS PRIOR TO COMMENCING WORK.
5. AT ALL LOCATIONS WHERE NEW CONSTRUCTION WILL INTERFACE
WITH EXISTING ELEMENTS, CUT THROUGH EXISTING STRUCTURE IN
STRAIGHT AND TRUE LINES TO INSURE A NEAT INTERFACE.
6. AT ALL LOCATIONS WHERE THE DEMOLITION OF A CONCRETE
MEMBER LEAVES THE ENDS OF REINF STEEL EXPOSED, PROVIDE THE
FOLLOWING:
A. CHIP CONCRETE FROM AROUND THE STEEL TO A DEPTH OF 1”.
B. CUT OFF REINF STEEL NOT LESS THAN 3/4” BELOW THE
CONCRETE SURFACE.
C. FILL THE CAVITY FLUSH WITH A HIGH MODULUS GEL EPOXY.
7. BEFORE DEMOLISHING ANY STRUCTURAL ELEMENT, INSTALL ALL
REQUIRED TEMPORARY AND/OR PERMANENT BRACING AND
SUPPORTS.
8. REMOVE COMPLETELY FROM THE SITE AND LEGALLY DISPOSE ALL
DEBRIS GENERATED BY THE DEMOLITION WORK AS THE WORK
PROGRESSES. STOCKPILING OF DEBRIS AND BURNING OF DEBRIS
ON THE PREMISES IS STRICTLY PROHIBITED.
MISCELLANEOUS
1. CONTRACTOR SHALL SUPPLY ALL ITEMS FOR ATTACHING MECHANICAL
AND ELECTRICAL EQUIPMENT TO THE BUILDING STRUCTURE TO
RESIST ALL LOADS. ATTACHMENT SHALL BE MADE SO AS NOT TO
OVERSTRESS STRUCTURAL MEMBERS. COORDINATE THE
ATTACHMENTS AND LOCATIONS OF THE EQUIPMENT WITH ALL
DISCIPLINES AND MANUFACTURER.
2. SUBSTITUTION OF EXPANSION ANCHORS FOR ADHESIVE ANCHORS OR
EMBEDDED ANCHORS SHOWN ON THE DRAWINGS WILL NOT BE
PERMITTED UNLESS APPROVED BY THE STRUCTURAL ENGINEER IN
ADVANCE.
3. THE CONTRACTOR SHALL PROVIDE THE FOLLOWING SERVICES AS
PART OF THE CONSTRUCTION SCOPE OF WORK:
A. VERIFICATION OF ALL DIMENSIONS, ELEVATIONS, OPENING
SIZES, MECHANICAL EQUIPMENT WEIGHTS PRIOR TO
STARTING WORK.
B. REVIEW AND APPROVE ALL SHOP DRAWINGS PRIOR TO
SUBMITTAL, NOTING CHANGES MADE WHICH DO NOT COMPLY
WITH DESIGN DRAWINGS.
EQUIPMENT ANCHORS PER
EQUIPMENT MANUFACTURERS
REQUIREMENTS
REFER TO ELECTRICAL PLANS & SPECIFICATIONS FOR EQUIPMENT
REQUIREMENTS, PAD SIZE, ACCESSORIES, AND LOCATIONS.
M
IN
3/4" CHAMFERED EDGE
EQUIP SIZE +6" ALL AROUND
EXISTING 10" THICK SLAB ON GRADE
NEUTRAL GROUND
RESISTOR (NGR)
EQUIPMENT. ASSUMED
500 LBS. SEE ELECTRICAL
AND MANUFACTURER FOR
FURTHER INFORMATION.
#5@6" OC EW T&B
4000 PSI CONCRETE EQUIPMENT PAD
PROVIDE ROUGHENED SURFACE & APPLY EPOXY
BONDING AGENT PRIOR TO PLACING PAD
In c h e s
/2
/4
1 2 3 4
D
C
B
A
79314
SCALE:
9150 CURRY FORD ROAD ORLANDO, FL. 32825
ORANGE COUNTY
ENGINEERING DIVISION
UTILITIES DEPARTMENT DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:FLORIDA LICENSE #
PROFESSIONAL ENGINEER
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
3/4" = 1'-0"
A u to d e s k D o c s
/O ra n g e C o u n ty
M is c
/1
E
W R
F E le c tr ic a l F u e l S to ra g e S
.r vt
/2
/2
:1 :5
P
M
STRUCTURAL NOTES AND DETAILS
EWRF ELECTRICAL AND MECHANICAL UPGRADES PRD
PRD
JVA
S-601
PAUL DICICCO, PE
3/4" = 1'-0"S-601
1 NGR EQUIPMENT PAD
SYMBOLS, NOTES & ABBREVIATIONS E-001
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
P.C.
F.D.
W.N.
E-001 NOTES.DWG
EWRF ELECTRICAL AND MECHANICAL UPGRADES
SCALE: AS NOTED
6965 PIAZZA GRANDE AVE., STE. 311
PHONE: (407) 745-5604
C.O.A. No. 8079
FAX: (407) 745-5603
WILLIAM C. NELSON, P.E.
Florida P.E. No. 42017
ORLANDO, FLORIDA 32835
C:
\U se rs
\N ic ol eB ar ne s\ El ec tri ca l D es ig n As so ci at es
\A
CT
IV
E-
O
RL
D oc um en ts
\A tk in s\
O ra ng e
Co un ty \Y
-9
\E
W
RF
E le ct ric al
F ue l\1 1.
_R eb id (G oo ds
S er vi ce s)
\d w g\ E-
N O
TE
S.
dw g, /1
8/
0:
:1
AM
, D
W G
To P
D F.
pc
ELECTRICAL SITE PLAN E-002
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
P.C.
F.D.
W.N.
E-002 ELEC SITE.DWG
EWRF ELECTRICAL AND MECHANICAL UPGRADES
SCALE: AS NOTED
6965 PIAZZA GRANDE AVE., STE. 311
PHONE: (407) 745-5604
C.O.A. No. 8079
FAX: (407) 745-5603
WILLIAM C. NELSON, P.E.
Florida P.E. No. 42017
ORLANDO, FLORIDA 32835
C:
\U se rs
\N ic ol eB ar ne s\ El ec tri ca l D es ig n As so ci at es
\A
CT
IV
E-
O
RL
D oc um en ts
\A tk in s\
O ra ng e
Co un ty \Y
-9
\E
W
RF
E le ct ric al
F ue l\1 1.
_R eb id (G oo ds
S er vi ce s)
\d w g\ E-
EL
EC
S
IT
E.
dw g, /1 8/
0:
:2
AM
, D W
G To
P D
F.
LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA
LA LA
OVERALL 12.47 KV SYSTEM SINGLE LINE DIAGRAM E-003
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
P.C.
F.D.
W.N.
E-003 12.47KV SYST SLD.DWG
EWRF ELECTRICAL AND MECHANICAL UPGRADES
SCALE: AS NOTED
6965 PIAZZA GRANDE AVE., STE. 311
PHONE: (407) 745-5604
C.O.A. No. 8079
FAX: (407) 745-5603
WILLIAM C. NELSON, P.E.
Florida P.E. No. 42017
ORLANDO, FLORIDA 32835
C:
\U se rs
\N ic ol eB ar ne s\ El ec tri ca l D es ig n As so ci at es
\A
CT
IV
E-
O
RL
D oc um en ts
\A tk in s\
O ra ng e
Co un ty \Y
-9
\E
W
RF
E le ct ric al
F ue l\1 1.
_R eb id (G oo ds
S er vi ce s)
\d w g\ E-
.4
7K V
SY
ST
S
LD
.d w g, /1 8/
0:
:2
AM
, D W
G To
P D
F.
ɸɸ
12.47 KV SWITCHGEAR SINGLE LINE E-004
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
P.C.
F.D.
W.N.
E-004 12.47 KV SWGR SL.DWG
EWRF ELECTRICAL AND MECHANICAL UPGRADES
SCALE: AS NOTED
6965 PIAZZA GRANDE AVE., STE. 311
PHONE: (407) 745-5604
C.O.A. No. 8079
FAX: (407) 745-5603
WILLIAM C. NELSON, P.E.
Florida P.E. No. 42017
ORLANDO, FLORIDA 32835
C:
\U se rs
\N ic ol eB ar ne s\ El ec tri ca l D es ig n As so ci at es
\A
CT
IV
E-
O
RL
D oc um en ts
\A tk in s\
O ra ng e
Co un ty \Y
-9
\E
W
RF
E le ct ric al
F ue l\1 1.
_R eb id (G oo ds
S er vi ce s)
\d w g\ E-
.4
KV
S W
GR
S
L.d w g, /1 8/
0:
:2
AM
, D W
G To
P D
F.
ɸ ɸ ɸ ɸ
12.47 KV GENERATOR SWITCHGEAR SINGLE LINE E-005
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
P.C.
F.D.
W.N.
E-005 12.47 KV GEN SWGR SL.DWG
EWRF ELECTRICAL AND MECHANICAL UPGRADES
SCALE: AS NOTED
6965 PIAZZA GRANDE AVE., STE. 311
PHONE: (407) 745-5604
C.O.A. No. 8079
FAX: (407) 745-5603
WILLIAM C. NELSON, P.E.
Florida P.E. No. 42017
ORLANDO, FLORIDA 32835
C:
\U se rs
\N ic ol eB ar ne s\ El ec tri ca l D es ig n As so ci at es
\A
CT
IV
E-
O
RL
D oc um en ts
\A tk in s\
O ra ng e
Co un ty \Y
-9
\E
W
RF
E le ct ric al
F ue l\1 1.
_R eb id (G oo ds
S er vi ce s)
\d w g\ E-
.4
KV
G
EN
S W
GR
S
L.d w g, /1 8/
0:
:2
AM
, D W
G To
P D
F.
12.47 KV SWITCHGEAR FRONT VIEW ELEVATIONS E-006
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
P.C.
F.D.
W.N.
E-006 12.47 KV SWGR ELEV.DWG
EWRF ELECTRICAL AND MECHANICAL UPGRADES
SCALE: AS NOTED
6965 PIAZZA GRANDE AVE., STE. 311
PHONE: (407) 745-5604
C.O.A. No. 8079
FAX: (407) 745-5603
WILLIAM C. NELSON, P.E.
Florida P.E. No. 42017
ORLANDO, FLORIDA 32835
C:
\U se rs
\N ic ol eB ar ne s\ El ec tri ca l D es ig n As so ci at es
\A
CT
IV
E-
O
RL
D oc um en ts
\A tk in s\
O ra ng e
Co un ty \Y
-9
\E
W
RF
E le ct ric al
F ue l\1 1.
_R eb id (G oo ds
S er vi ce s)
\d w g\ E-
.4
KV
S W
GR
E
LE
V.
dw g, /1
8/
0:
:2
AM
, D
W G
To P
D F.
R
R AG WR AG W R AG W R AG WR AG W
R
R AG WR AG W R AG W R AG WR AG WR AG WR AG W
12.47 KV GENERATOR SWITCHGEAR
FRONT VIEW ELEVATIONS E-007
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
P.C.
F.D.
W.N.
E-007 12.47KV GEN SWGR ELEV.DWG
EWRF ELECTRICAL AND MECHANICAL UPGRADES
SCALE: AS NOTED
6965 PIAZZA GRANDE AVE., STE. 311
PHONE: (407) 745-5604
C.O.A. No. 8079
FAX: (407) 745-5603
WILLIAM C. NELSON, P.E.
Florida P.E. No. 42017
ORLANDO, FLORIDA 32835
C:
\U se rs
\N ic ol eB ar ne s\ El ec tri ca l D es ig n As so ci at es
\A
CT
IV
E-
O
RL
D oc um en ts
\A tk in s\
O ra ng e
Co un ty \Y
-9
\E
W
RF
E le ct ric al
F ue l\1 1.
_R eb id (G oo ds
S er vi ce s)
\d w g\ E-
.4
7K V
GE
N
S W
GR
E
LE
V.
dw g, /1
8/
0:
:2
AM
, D
W G
To P
D F.
MAIN ELECTRICAL/BLOWER BUILDING SWITCHGEAR
ROOM ELECTRICAL PLAN E-008
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
P.C.
F.D.
W.N.
E-008 MAIN ELECT BLWR BLDG.DWG
EWRF ELECTRICAL AND MECHANICAL UPGRADES
SCALE: AS NOTED
6965 PIAZZA GRANDE AVE., STE. 311
PHONE: (407) 745-5604
C.O.A. No. 8079
FAX: (407) 745-5603
WILLIAM C. NELSON, P.E.
Florida P.E. No. 42017
ORLANDO, FLORIDA 32835
C:
\U se rs
\N ic ol eB ar ne s\ El ec tri ca l D es ig n As so ci at es
\A
CT
IV
E-
O
RL
D oc um en ts
\A tk in s\
O ra ng e
Co un ty \Y
-9
\E
W
RF
E le ct ric al
F ue l\1 1.
_R eb id (G oo ds
S er vi ce s)
\d w g\ E-
M
AI
N E
LE
CT
B
LW
R
BL
D G.
dw g, /1
8/
0:
:2
AM
, D
W G
To P
D F.
MAIN ELECTRICAL/BLOWER BUILDING GENERATOR
ROOM POWER PLAN E-009
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
P.C.
F.D.
W.N.
E-009 ELEC_BLWR BLDG GEN PWR.DWG
EWRF ELECTRICAL AND MECHANICAL UPGRADES
SCALE: AS NOTED
6965 PIAZZA GRANDE AVE., STE. 311
PHONE: (407) 745-5604
C.O.A. No. 8079
FAX: (407) 745-5603
WILLIAM C. NELSON, P.E.
Florida P.E. No. 42017
ORLANDO, FLORIDA 32835
C:
\U se rs
\N ic ol eB ar ne s\ El ec tri ca l D es ig n As so ci at es
\A
CT
IV
E-
O
RL
D oc um en ts
\A tk in s\
O ra ng e
Co un ty \Y
-9
\E
W
RF
E le ct ric al
F ue l\1 1.
_R eb id (G oo ds
S er vi ce s)
\d w g\ E-
EL
EC
_B
LW
R
BL
D G
GE
N
P W
R.
dw g, /1 8/
0:
:2
AM
, D W
G To
P D
F.
ELECTRICAL DETAILS-1 E-010
9150 CURRY FORD ROAD ORLANDO, FL. 32825
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
P.C.
F.D.
W.N.
E-010 ELECTRICAL DETAILS-1.DWG
EWRF ELECTRICAL AND MECHANICAL UPGRADES
SCALE: AS NOTED
6965 PIAZZA GRANDE AVE., STE. 311
PHONE: (407) 745-5604
C.O.A. No. 8079
FAX: (407) 745-5603
WILLIAM C. NELSON, P.E.
Florida P.E. No. 42017
ORLANDO, FLORIDA 32835
C:
\U se rs
\N ic ol eB ar ne s\ El ec tri ca l D es ig n As so ci at es
\A
CT
IV
E-
O
RL
D oc um en ts
\A tk in s\
O ra ng e
Co un ty \Y
-9
\E
W
RF
E le ct ric al
F ue l\1 1.
_R eb id (G oo ds
S er vi ce s)
\d w g\ E-
EL
EC
TR
IC
AL
D
ET
AI
LS
-1
.d w g, /1 8/
0:
:2
AM
, D W
G To
P D
F.
ELECTRICAL DETAILS-2 E-011
DRAWING NO. :
REV DATE DESCRIPTION
DESIGNED BY:
DRAWN BY:
CHECKED BY:
OCU FILE NO.:
CADD FILE:
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
P.C.
F.D.
W.N.
E-011 ELECTRICAL DETAILS-2.DWG
EWRF ELECTRICAL AND MECHANICAL UPGRADES
SCALE: AS NOTED
6965 PIAZZA GRANDE AVE., STE. 311
PHONE: (407) 745-5604
C.O.A. No. 8079
FAX: (407) 745-5603
WILLIAM C. NELSON, P.E.
Florida P.E. No. 42017
ORLANDO, FLORIDA 32835
C:
\U se rs
\N ic ol eB ar ne s\ El ec tri ca l D es ig n As so ci at es
\A
CT
IV
E-
O
RL
D oc um en ts
\A tk in s\
O ra ng e
Co un ty \Y
-9
\E
W
RF
E le ct ric al
F ue l\1 1.
_R eb id (G oo ds
S er vi ce s)
\d w g\ E-
EL
EC
TR
IC
AL
D
ET
AI
LS
-2
.d w g, /1 8/
0:
:2
AM
, D W
G To
P D
F.
| Sheets and Views |
| G100 |
File details come from the government source that posted it. Updated .