These construction plans are for the University Shores Sewer Improvements Package No. 4, prepared by the Orange County Utilities Department's Engineering Division in Florida for April 2025. The project involves sewer infrastructure improvements across multiple subareas, including Andrew Place (SA 3886), Bradford Park (SA 3890), Lake Irma Estates (SA 3891), Pinewood Village (SA 3943), Allison Oaks (SA 3695), and Harbor East (SA F3166). The documents include detailed engineering drawings, utility maps, site civil details, and standard construction specifications for gravity sewer mains, manholes, service laterals, and related infrastructure improvements.
The technical specifications outline comprehensive requirements for pipe installation, trenching, bedding, manhole construction, and restoration procedures. The project includes various pipe materials (PVC and ductile iron), ranging from 4-inch to 12-inch diameters, with specific installation guidelines for different surface types including light highway and urban environments. The plans emphasize strict compaction standards, dewatering protocols, utility protection, and adherence to Orange County Utilities Department's Standards and Construction Specifications Manual. The documents provide extensive technical details for contractors, including specific notes on excavation, backfilling, connections, and restoration requirements to ensure high-quality infrastructure implementation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
April 2025
ATTENTION IS DIRECTED TO THE FACT THAT THESE
PLANS MAY HAVE BEEN REDUCED IN SIZE BY
REPRODUCTION. THIS MUST BE CONSIDERED WHEN
OBTAINING SCALED DATA. DIMENSION
INFORMATION SHOULD NOT BE OBTAINED BY
SCALING THE PLANS.
BYRON W. BROOKS, A.I.C.P.
COUNTY ADMINISTRATOR
ED TORRES, M.S.,P.E.,LEED AP
DIRECTOR ORANGE COUNTY UTILITIES DEPARTMENT
JERRY L. DEMINGS
ORANGE COUNTY MAYOR
NICOLE H. WILSON
DISTRICT 1
CHRISTINE MOORE
DISTRICT 2
MAYRA URIBE
DISTRICT 3
MARIBEL GOMEZ CORDERO
DISTRICT 4
MARTINEZ
DISTRICT 5
DISTRICT 6
BID SET
DATEREV DESCRIPTION
DRAWN BY: X
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
DRAWING NO.:LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
GENERAL NOTES
G 300
OCU STANDARD GENERAL NOTES
1. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN EXCAVATING IN PROXIMITY OF
INCLUDING, BUT NOT LIMITED TO: WATER MAINS, WASTEWATER FORCE MAINS, GRAVITY MAINS, RECLAIMED WATER MAINS, ELECTRIC, GAS, CABLE TV, TELECOMMUNICATIONS, STORM WATER, FIBER OPTIC AND OTHER UNDERGROUND FACILITIES. MAIN LOCATIONS SHOWN ON PLANS MAY NOT BE EXACT.
THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING EXISTING UTILITY LOCATIONS.
2. SHOULD A PIPE EMERGENCY OCCUR, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OCU DISPATCH OPERATOR (407-836-2777) AND THE OCU INSPECTOR. EMERGENCY NOTIFICATION SHALL ALSO BE PROVIDED TO THE CITY OF MAITLAND'S APOPKA DISPATCH (407) 539-6262 FOR LOCATION 3.
3. THE CONTRACTOR SHALL NOTIFY THE OCU CONSTRUCTION INSPECTION SECTION, FIELD SERVICES DIVISION AT LEAST TEN (10) CALENDAR DAYS PRIOR TO COMMENCEMENT OF THE CONSTRUCTION PROJECT BY CALLING (407) 254-9798, AND CITY OF MAITLANS PUBLIC WORKS (407) 539-6252 FOR
LOCATION 3.
4. THE CONTRACTOR SHALL NOTIFY THE OCU CONSTRUCTION INSPECTOR IN ACCORDANCE WITH TABLE
4110-1 UTILITIES' SCHEDULE OF NOTIFICATIONS UTILITIES STANDARDS AND CONSTRUCTION
SPECIFICATIONS MANUAL, 2021. THIS SAME NOTIFICATION SHALL ALSO BE PROVIDED TO THE CITY OF
MAITLAND PUBLIC WORKS (407) 539-6252 FOR LOCATION 3.
5. THE MATERIALS, PRODUCTS, AND CONSTRUCTION OF ALL UTILITIES CONNECTING TO THE OCU SYSTEM SHALL BE IN CONFORMANCE WITH THE STANDARDS, CONSTRUCTION SPECIFICATIONS, AND APPENDIX D .
6. ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO: WATER MAINS, FORCE MAINS, RECLAIMED WATER MAIN, SANITARY GRAVITY PIPES, STORM WATER PIPES, ELECTRIC, TELEPHONE, GAS, POLES AND STAYS, CABLE TV AND OTHER UTILITY FACILITIES WITHIN THE LIMITS OF THE PROJECT WILL BE
SUPPORTED AND PROTECTED AGAINST DAMAGE DURING CONSTRUCTION.
7. THE CONTRACTOR SHALL ADJUST ALL EXISTING OCU MAINS AND FACILITIES IN CONFLICT WITH NEW
GRADE, NEW OR ALTERED ROADWAYS, SIDEWALKS, DRIVEWAYS, CURBS, OR STORM WATER
IMPROVEMENTS. OCU FACILITIES TO BE ADJUSTED INCLUDE, BUT ARE NOT LIMITED TO: PIPELINES, PUMP STATIONS, VALVE BOXES, AIR RELEASE VALVES, FIRE HYDRANTS, MANHOLE COVERS, AND METERS. ALL
ADJUSTMENTS SHALL BE MADE TO CURRENT STANDARDS.
8. ONLY OCU PERSONNEL SHALL OPERATE EXISTING OCU WATER, WASTEWATER, AND RECLAIMED WATER VALVES. THE CONTRACTOR IS RESPONSIBLE FOR OPERATING ANY NEWLY INSTALLED VALVE THAT HAS NOT BEEN CLEARED FOR USAGE BY FDEP AND OCU. THE CONTRACTOR SHALL COORDINATE VALVE OPERATION WITH THE OCU INSPECTOR. FOR OPERATION OF MAINS NOT OWNED BY OCU, IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE APPROPRIATE UTILITY REPRESENTATIVE.
9. CONSTRUCTION ACTIVITIES SHALL NOT CAUSE INTERRUPTIONS IN WATER, WASTEWATER, OR RECLAIMED WATER SERVICE. THE CONTRACTOR SHALL COORDINATE PRE-APPROVED INTERRUPTIONS OF SERVICE WITH THE OCU INSPECTOR SEVEN (7) WORKING DAYS IN ADVANCE AND WRITTEN NOTICE
SHALL BE GIVEN TO AFFECTED CUSTOMERS AT LEASE FOUR (4) WORKING DAYS IN ADVANCE.
10.THE CONTRACTOR SHALL PROVIDE FOR BYPASSING AND/OR HAULING OF WASTEWATER DURING
APPROVED INTERRUPTIONS OF WASTEWATER FLOWS AND CONNECTIONS. THE CONTRACTOR SHALL
SUBMIT A BYPASS OR HAUL PLAN, REVIEWED AND APPROVED BY A PROFESSIONAL ENGINEER TO UTILITIES AND TO THE INSPECTOR FOR APPROVAL PRIOR TO IMPLEMENTATION BY CONTRACTOR.
11. ALL VALVES INSTALLED AS PART OF THIS CONSTRUCTION PROJECT SHALL REMAIN CLOSED DURING CONSTRUCTION. KEEP VALVES ON ALL WET TAPS CLOSED UNTIL CLEARED BY FDEP. DO NOT CONNECT NEWLY CONSTRUCTED WATER MAINS TO ANY EXISTING WATER MAINS UNLESS CLEARED BY FDEP AND
OCU.
12.THE CONTRACTOR SHALL PROVIDE A JUMPER ASSEMBLY WITH AN APPROVED BACKFLOW PREVENTER
FOR MAKING TEMPORARY CONNECTIONS TO AN EXISTING POTABLE WATER SOURCE IN ORDER TO
CHLORINATE AND FLUSH NEW WATER MAINS WITH POTABLE WATER. ANY TEMPORARY POTABLE WATER CONNECTIONS TO RECLAIMED WATER OR FORCE MAIN SHALL ALSO BE EQUIPPED WITH AN APPROVED
BACKFLOW PREVENTER.
13.FOR PVC PIPE, NO JOINT DEFLECTION OR PIPE BENDING IS ALLOWED. ALIGHMENT CHANGE SHALL BE
MADE ONLY WITH FITTINGS.
14.FOR DIP PIPE, LONG RADIUS CURVES, EITHER HORIZONTAL OR VERTICLE, MAY BE INSTALLED WITH STANDARD PIPE BY DEFLECTIONS AT THE JOINTS. MAXIMUM DEFLECTIONS AT PIPE JOINTS, FITTINGS AND LAYING RADIUS FOR THE VARIOUS PIPE LENGTHS SHALL NOT EXCEED 75 PERCENT OF THE PIPE
MANUFACTURES'S RECOMMENDATION.
15.FOR APPROVED PVC OR HDPE PIPE USED IN A HORIZONTAL DIRECTIONAL DRILL INSTALLATION, THE CURVATURE AND/OR DEFLECTION SHALL NOT EXCEED THE PARAMETERS ESTABLISHED IN UTILITIES
STANDARDS AND CONSTRUCTION SPECIFICATIONS MANUAL, 2021.
16. ALL DAMAGE TO ORANGE COUNTY INFRASTRUCTURE, PIPELINES, AND ASSETS SHALL BE REPAIRED IMMEDIATELY BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE WITH AN APPROVED METHOD BY THE COUNTY. IF THE REPAIR IS NOT PERFORMED IN A TIMELY MANNER, AS DETERMINED BY THE ORANGE COUNTY UTILITY INSPECTOR, ORANGE COUNTY MAY PERFORM REPAIRS AND THE CONTRACTOR WILL BE
CHARGED FOR ALL EXPENSES ASSOCIATED WITH THE REPAIR.
17.THE CONTRACTOR SHALL BE LIABLE FOR ANY AND ALL SANITARY SEWER OVERFLOWS (SSO)
ASSOCIATED WITH THE WORK, REGARDLESS OF FAULT. THE CONTRACTOR WILL BE ASSESSED
PENALTIES FOR ANY AND EACH SSO AS SPECIFIED IN SECTION 01025, 1.03. E.
PROJECT GENERAL NOTES
18. ALL UTILITIES FACILITIES CONSTRUCTION CONNECTING TO THE ORANGE COUNTY PUBLIC UTILITIES
SYSTEM SHALL CONFORM TO THE ORANGE COUNTY UTILITIES STANDARDS AND CONSTRUCTION
SPECIFICATIONS MANUAL, AND BE ONE OF THE APPROVED PRODUCTS LISTED IN APPENDIX 'D' OF THE
MANUAL.
19.BENCHMARK LOCATIONS AND ELEVATIONS ARE SHOWN IN THE PLANS AS REPRESENTED BY THE SURVEYOR AT THE TIME OF SURVEY. CONTRACTOR SHALL VERIFY ITS CORRECTNESS AT THE TIME OF CONSTRUCTION AND INSTALL HIS OWN TEMPORARY BENCHMARKS. ANY DISCREPANCIES SHALL BE
IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OCU UTILITIES RESIDENT PROJECT
REPRESENTATIVE (RPR).
20.ALL NORTHING AND EASTING COORDINATES ARE BASED ON THE STATE PLANE COORDINATE SYSTEM.
STATIONING IS FOR REFERENCE ONLY.
21.COORDINATION AND COMMUNICATIONS WITH ORANGE COUNTY STAFF SHALL BE MADE THROUGH THE
ORANGE COUNTY UTILITIES CONSTRUCTION DIVISION INSPECTOR.
22.ORANGE COUNTY UTILITIES DEPARTMENT TELEPHONE NUMBERS:
407-836-2777 ORANGE COUNTY UTILITIES DISPATCH
407-254-9798 ORANGE COUNTY UTILITIES CONSTRUCTION DIVISION
407-254-9680 ORANGE COUNTY UTILITIES WATER RECLAMATION DIVISION
407-254-9850 ORANGE COUNTY UTILITIES WATER DIVISION
407-254-9900 ORANGE COUNTY UTILITIES ENGINEERING DIVISION
23.THE CONTRACTOR SHALL NOTIFY THE ORANGE COUNTY PUBLIC SCHOOLS TRANSPORTATION SERVICES
(407) 317-3800, TWO(2) WEEKS IN ADVANCE OF ANY PHASE OF CONSTRUCTION TO COORDINATE SCHOOL
BUS STOP RELOCATION OR BUS RE-ROUTING IF NECESSARY.
24.THE CONTRACTOR SHALL NOTIFY LYNX TRANSPORTATION SYSTEM (407) 841-2279, TWO(2) WEEKS IN
ADVANCE OF ANY PHASE OF CONSTRUCTION TO COORDINATE BUS STOP RELOCATION OR BUS
RE-ROUTING IF NECESSARY.
25.PRIOR TO THE START OF ANY WORK, THE CONTRACTOR SHALL PLAN AND SCHEDULE THE SEQUENCE OF WORK IN ORDER TO PREVENT UNNECESSARY DELAYS OR COSTS ASSOCIATED WITH CRITICAL PATH
ITEMS OF THE WORK.
26.THE CONTRACTOR SHALL BRING ANY DESIGN DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE
ENGINEER, IN WRITING, PRIOR TO CONSTRUCTION OR AS SOON AS DISCOVERED.
27.THE OWNER SHALL FURNISH THE FDEP WASTEWATER PERMIT(S) AND THE FDOT UTILITY PERMIT(S). THE CONTRACTOR SHALL OBTAIN ALL OTHER PERMITS REQUIRED FOR THE PROJECT. THE CONTRACTOR SHALL BECOME FAMILIAR WITH AND ABIDE BY ALL PERMIT CONDITIONS, INSPECTION SCHEDULES, AND
OTHER RELEVANT REGULATORY AGENCY RULES AND SPECIAL CONDITIONS.
28.LOCATIONS, ELEVATIONS AND DIMENSIONS OF EXISTING UTILITIES AND STRUCTURES ARE
APPROXIMATE. WHILE CONSIDERABLE EFFORT HAS BEEN MADE BY THE OWNER, THE SURVEYOR, THE VARIOUS UTILITY COMPANIES AND THE ENGINEER TO ACCURATELY LOCATE EXISTING LINES AND APPURTENANCES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL UTILITY AND STRUCTURE LOCATIONS, ELEVATIONS AND DIMENSIONS BY UTILIZING EXPLORATORY EXCAVATION, WHICH SHALL BE MADE 7 DAYS OR 1000 FEET IN ADVANCE OF THE WORK, WHICHEVER IS GREATER. IF THERE IS A POTENTIAL CONFLICT, THE CONTRACTOR IS TO NOTIFY THE ENGINEER IMMEDIATELY. NO CLAIMS FOR
DELAYS WILL BE PAID UNLESS THIS PROCEDURE HAS BEEN FULLY FOLLOWED. ANY DAMAGE TO
UTILITIES, STRUCTURES AND/OR SERVICES SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE, IN A
MANNER APPROVED BY AND COORDINATED WITH THE UTILITY OWNER. CONTRACTOR SHALL BE
RESPONSIBLE FOR CONTACTING THE UTILITY OWNER OF ANY UNINTENDED INTERRUPTION TO SERVICE
OR DAMAGE TO EXISTING STRUCTURES OR UTILITIES.
29.IMMEDIATELY AT ONSET OF CONSTRUCTION, CONTRACTOR SHALL FIELD VERIFY HORIZONTAL AND VERTICAL LOCATIONS OF ALL EXISTING UTILITIES CRITICAL TO COMPLETING THE PROJECT (INCLUDING WATER, SEWER, RECLAIMED WATER, POWER, TELEPHONE, GAS, FIBER OPTIC AND CABLE TV) AND SHALL EVALUATE POTENTIAL CONFLICTS IN A WRITTEN REPORT. ANY CONFLICTS SHALL BE REPORTED TO
ENGINEER/OWNER IMMEDIATELY UPON DISCOVERY AND DETAILED IN THE REPORT.
30.CONTRACTOR SHALL COORDINATE WITH ALL OTHER UTILITY OWNERS FOR RESOLUTION OF CONFLICTS.
CONTRACTOR SHALL HAVE 48 HOURS TO DETERMINE THE RESOLUTION OF ANY UNKNOWN OR
UNFORESEEN CONFLICTS. COSTS INCURRED SHALL BE BORNE BY THE UTILITY OWNER AND/OR
CONTRACTOR AND NO CLAIMS MAY BE MADE AGAINST ORANGE COUNTY OR THE ENGINEER FOR THESE CONFLICTS. NO ADDITIONAL COMPENSATION SHALL BE MADE FOR THE PERIOD OF TIME TO RESOLVE
ANY CONFLICTS.
31.SUPPORT AND PROTECT ALL EXISTING UTILITIES. CONTRACTOR SHALL CONTACT UTILITY OWNERS FOR LOCATION OF ALL EXISTING FACILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH UTILITY OWNERS AND FOR PROVIDING TEMPORARY SUPPORT FOR THE UTILITY POLES, ANCHOR GUYS, AND ALL OTHER UTILITIES DURING CONSTRUCTION.
32.THE CONTRACTOR SHALL FIND AND MAINTAIN HIS OWN EQUIPMENT AND MATERIAL STORAGE YARDS AT
NO COST TO THE COUNTY.
33.ALL CONCRETE TO BE REMOVED SHALL BE SAW CUT AT THE NEAREST GOOD JOINT. CURB/GUTTER SHALL BE SAW CUT BETWEEN ASPHALT AND CONCRETE PRIOR TO REMOVAL. ALL SAW CUTTING SHALL
BE WET CUT TO CONTROL DUST.
34.PROTECT EXISTING IMPROVEMENTS TO THE MAXIMUM EXTENT POSSIBLE. RESTORE ALL EXISTING IMPROVEMENTS AND DISTURBED AREAS TO ORIGINAL CONDITION. PAVEMENT TO BE RESTORED IN ACCORDANCE WITH THE PAVEMENT RESTORATION DETAILS SHOWN ON THE CONSTRUCTION DETAIL SHEETS. ALL DAMAGED MAILBOXES, IRRIGATION SYSTEMS, SOD, LANDSCAPING, FENCING, SIDEWALK, ROADWAY PAVEMENT AND OTHER IMPROVEMENTS SHALL BE RESTORED TO ORIGINAL OR BETTER
CONDITION.
35.NO VALVE BOXES, METERS, PORTIONS OF MANHOLES, OR OTHER APPURTENANCES OF ANY KIND
RELATING TO ANY UNDERGROUND UTILITIES SHALL BE LOCATED IN ANY PORTION OF A
CURB-AND-GUTTER SECTION. CONTRACTOR SHALL ADVISE ENGINEER IMMEDIATELY UPON DISCOVERY
OF A POTENTIAL CONFLICT.
36.THE DISPOSAL OF ANY EXCESS EARTH WORK MATERIAL SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR.
37.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER SALVAGE AND/OR DISPOSAL OF ALL MATERIALS AND EQUIPMENT IN ACCORDANCE WITH THE SPECIFICATIONS AND AS DIRECTED BY THE
ORANGE COUNTY UTILITIES INSPECTOR.
38.EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO, OR AS THE FIRST STEP IN
CONSTRUCTION AND ARE THE MINIMUM REQUIRED. CONTRACTOR SHALL FURNISH ADDITIONAL
CONTROLS AS NEEDED AT NO ADDITIONAL COST. MATERIALS FROM WORK ON THIS PROJECT SHALL BE CONTAINED AND NOT ALLOWED TO COLLECT ON ANY OFF PERIMETER AREAS OR IN WATERWAYS. SILK SCREENS, HAY BALES, AND TURBIDITY BARRIERS MUST REMAIN IN PLACE AND IN GOOD CONDITION AT ALL LOCATIONS IN PLANS OR AS REQUIRED UNTIL THE CONTRACT IS COMPLETED AND SOILS ARE STABILIZED AND VEGETATION IS ESTABLISHED. MEASURES SHOWN ON THE PLANS ARE MINIMUM REQUIRED, AND THE CONTRACTOR SHALL ENSURE THAT THERE IS NO DIRECT OR INDIRECT DISCHARGE
OF CONSTRUCTION MATERIALS IN TURBID WATERS TO OFF SITE AREAS OR WATERWAYS.
39.ALL EXISTING PAVEMENT MARKINGS AND MESSAGES, WHICH ARE TO BE OBLITERATED, SHALL BE
INVENTORIED AND RESTORED TO ORIGINAL CONDITION AND DAMAGED ONES REPLACED (UPON
COMPLETION OF CONSTRUCTION AND PRIOR TO REINSTATING VEHICULAR TRAFFIC) BY THE
CONTRACTOR, UNLESS OTHERWISE SPECIFIED IN THE PLANS OR LATEST DESIGN STANDARD. ALL PERMANENT PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC WITH GLASS BEADS. TEMPORARY PAVEMENT MARKINGS MAY BE PAINT PRODUCTS AND RETRO-REFLECTIVE PAVEMENT MARKERS (ON
SURFACES TO BE MILLED AND RESURFACED) OR TEMPORARY TAPE (ON ALL AREAS NOT BEING
RESURFACED). TEMPORARY TAPE SHALL BE 3M BRAND STAMARK REMOVABLE TAPE, SERIES 780, WET REFLECTIVE TEMPORARY TAPE OR APPROVED EQUAL. THE USE OF "FOIL BLACK" TYPES OF TEMPORARY TAPE IS NOT PERMITTED. 3M BRAND REMOVABLE BLACK MASK TAPE, SERIES 145, IS THE ONLY
APPROVED MATERIAL FOR "BLACKING OUT" EXISTING PAVEMENT MARKINGS ON FINAL ROADWAY
SURFACES OR SURFACES NOT BEING PAVED. UNDER NO CIRCUMSTANCES WILL BLACK PAINT OR
GRINDING BE PERMITTED. ALL CONFLICTING EXISTING MARKINGS SHALL BE REMOVED.
40.CONTRACTOR'S USE OF THE PREMISES SHALL BE CONFINED TO THE LIMITS OF THE EXISTING RIGHT OF WAY AND/OR EASEMENTS. ALL PUBLIC AND PRIVATE PROPERTY AFFECTED BY THE CONSTRUCTION SHALL BE PROTECTED WHERE POSSIBLE. ALL AREAS DISTURBED AS PART OF THIS WORK SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION AT NO ADDITIONAL COST TO THE OWNER. ALL EXISTING SODDED AREAS DISTURBED DURING THE CONSTRUCTION SHALL BE REPLACED WITH THE SAME TYPE OF SOD IN CONFORMANCE WITH THE STANDARD SPECIFICATIONS. FIELD ENGINEER SHALL APPROVE THE REMOVAL AND REPLACEMENT OF EXISTING IRRIGATION SYSTEMS, AS REQUIRED, AT NO ADDITIONAL COST TO THE COUNTY OR PROPERTY OWNER. PROPER TEMPORARY ADJUSTMENTS SHALL BE DONE AT SUCH TIME TO MAINTAIN IRRIGATION SYSTEMS FROM BEING INTERRUPTED FOR EXTENDED PERIODS
DURING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE OF ALL NEWLY
PLANTED GRASS OR VEGETATION UNTIL WELL ESTABLISHED AND ACCEPTED BY THE COUNTY.
41."GEOTECHNICAL REPORT FOR 100% DESIGN, OCU GRAVITY SEWER R/R REPLACEMENT PACKAGE THREE, ORANGE COUNTY, FLORIDA, AEA PROJECT NO. 2014707-4” BY ANTILLIAN ENGINEERING ASSOCIATES, INC.
DATED AUGUST 7, 2019 WAS USED IN THE DESIGN OF THE PLANNED FACILITIES. THE CONTRACTOR SHALL USE THIS INFORMATION TOGETHER WITH ANY OTHER INFORMATION AVAILABLE TO DETERMINE THE NEED FOR AND COST OF DEWATERING. THE CONTRACTOR SHALL INCLUDE DEWATERING COSTS WITH THE UNIT PRICE FOR ASSOCIATED BID ITEMS. NO SEPARATE DEWATERING COSTS OR EXPENSES WILL BE
APPROVED.
EXCAVATION AND SHORING
42.ALL EXCAVATIONS SHALL CONFORM TO THE REQUIREMENTS OF THE OSHA TRENCH SAFETY ACT. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER STORAGE AND/OR DISPOSAL OF ALL EXCESS OR
UNSUITABLE EXCAVATED MATERIAL.
43.CONTRACTOR SHALL PROVIDE ENGINEERED SHORING SYSTEM PER SPECIFICATION SECTIONS 02220, 02360. SUBMIT AS SHOP DRAWING SIGNED AND SEALED BY A LICENSED FLORIDA P.E. SIGNED AND SEALED PLANS SHALL BE SUBMITTED TO THE OWNER FOR REVIEW AND APPROVAL PRIOR TO START OF CONSTRUCTION. SUBMITTAL FOR LOCATION 3 SHALL ALSO BE APPROVED BY THE CITY OF MAITLAND PRIOR TO IMPLEMENTING. THE COST OF ALL MATERIALS FOR SHORING OF EXCAVATIONS SHALL BE
INCLUDED IN THE UNIT PRICE FOR RELATED CONSTRUCTION PAY ITEMS.
44.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY TEMPORARY CONTROLS AND/OR STRUCTURES REQUIRED TO MAINTAIN SUITABLE AND SAFE WORKING CONDITIONS AT ALL TIMES. SUCH ITEMS SHALL
BE REMOVED ONCE THAT PORTION OF WORK HAS BEEN COMPLETED.
45.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STABILITY OF EMBANKMENTS AND SHALL REPLACE ANY PORTION WHICH, IN THE OPINION OF THE ENGINEER OR RPR, HAS BECOME DISPLACED DUE TO
EROSION OR DUE TO CARELESSNESS OR NEGLIGENCE ON THE PART OF THE CONTRACTOR.
BYPASS AND DEWATERING
46.COLLECTION SYSTEM BYPASS SHALL BE PROVIDED PER SPECIFICATION SECTION 01516. TEMPORARY
BYPASS PIPING SHALL BE LAID ABOVE GROUND WHERE PRACTICAL, AND LAID WITHIN EXISTING RIGHT OF WAY AND EASEMENTS. TEMPORARY BYPASS PIPING SHALL BE LAID BELOW GRADE AT ALL ROADWAY, DRIVEWAY AND SIDEWALK CROSSINGS.
47.ALL PAVED SURFACES DISTURBED FOR INSTALLATION OF BYPASS PIPING SHALL BE TEMPORARILY RESTORED PER FIGURE A613. WHERE SHOWN, LOCATION OF BYPASS PUMP SKIDS AND RESTORATION IS
APPROXIMATE IN NATURE AND DEPICTED FOR INFORMATION ONLY. CONTRACTOR SHALL BE
RESPONSIBLE FOR FINAL LOCATION OF BYPASS PUMPS AND RESTORATION AT NO ADDITIONAL COST TO
THE COUNTY.
48.IMMEDIATELY UPON REMOVAL OF BYPASS, GROUT ALL CORED STRUCTURE PENETRATIONS.
49.ALL DRAINAGE FACILITIES THAT ARE CROSSED AND/OR DISTURBED DURING CONSTRUCTION SHALL REMAIN FUNCTIONAL AT ALL TIMES OR THE CONTRACTOR SHALL INSTALL FACILITIES TO MAINTAIN THE
FLOW, AT NO ADDITIONAL COST TO THE OWNER.
50.CONTRACTOR SHALL PROVIDE ENGINEERED DEWATERING SYSTEM PER SPECIFICATION SECTION 02140.
SHOP DRAWING SUBMITTAL SHALL BE SIGNED AND SEALED BY A LICENSED FLORIDA GEOTECHNICAL ENGINEER. DEWATERING PLAN SHALL PROVIDE MEANS FOR OVERCOMING EXISTING PIPE TRENCH AND
BEDDING WHICH MAY INCLUDE STONE.
51.CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DE-WATERING REQUIRED DURING CONSTRUCTION AND
TO OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR THE TEMPORARY DE-WATERING.
52.MAINTAIN UTILITY SERVICES AT ALL TIMES. IF BY-PASS OR WELL POINT PUMPING IS NECESSARY, USE DIESEL ENGINES WITH QUIET PACK SYSTEM OR ELECTRIC MOTORS, TO KEEP NOISE TO AN ABSOLUTE MINIMUM (SPECIFICATION SECTION 01516). BY-PASS PUMPS SHALL HAVE AT LEAST ONE (1) BACKUP UNIT IN PLACE, AND SHALL BE ATTENDED BY A COMPETENT OPERATOR AT ALL TIMES WHEN IN USE. ALL DISCHARGE ACCESSORIES SHALL BE PVC, HARD RUBBER OR OTHER SUITABLE MATERIAL WITH NO LEAKING JOINTS. SOFT/LAYFLAT STYLE HOSE IS NOT ACCEPTABLE. SUBMITTALS FOR WELL POINT LAYOUT AND EQUIPMENT ARE REQUIRED PRIOR TO START OF WORK. DEWATERING SYSTEM SHALL BE UTILIZED IN ACCORDANCE WITH GOOD STANDARD PRACTICES AND MUST BE EFFICIENT ENOUGH TO LOWER THE WATER LEVEL IN ADVANCE OF EXCAVATION TO KEEP THE TRENCH BOTTOM AND SIDES FIRM AND DRY. NO POLLUTED WATERS SHALL BE DISCHARGED INTO STORM SYSTEM OR BODIES OF WATER.
BEFORE DISCHARGE OF PRODUCED GROUND WATER TO ANY SURFACE WATER OF THE STATE FROM A
NON-CONTAMINATED SITE, ANALYTICAL TESTS ON SAMPLES OF DISCHARGE WATER SHALL BE
PERFORMED TO DETERMINE CONTAMINATION. TEST RESULTS MUST MEET MINIMUM REQUIREMENTS SET
BY FDEP [DOCUMENT 62-621.300(2) GENERIC PERMIT FOR THE DISCHARGE OF PRODUCED
GROUNDWATER FROM NON-CONTAMINATED SITE ACTIVITY]. ANY DEWATERING DRAINAGE DISCHARGED INTO SANITARY SEWERS MUST BE APPROVED BY ORANGE COUNTY UTILITIES BEFORE DISCHARGING.
UTILITY CONSTRUCTION
53.PIPE SIZES ON PLANS ARE NOMINAL IN DIAMETER.
54.PIPE LENGTHS SHOWN ON PLANS ARE APPROXIMATE. ACTUAL LENGTHS ARE TO BE DETERMINED BY
THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION.
55.ALL EXISTING AND NEW OCU WATER AND SEWER VALVES, VALVE BOXES, AND MANHOLES SHALL BE PROTECTED AND ADJUSTED TO FINISHED GRADE AS SHOWN ON THE DRAWINGS. VALVE AND VALVE BOXES SHALL REMAIN ACCESSIBLE AT ALL TIMES. ANY VALVES THAT MIGHT BE COVERED DURING
CONSTRUCTION SHALL BE MARKED WITH A MARKER (GREEN FOR SEWER, BLUE FOR WATER, AND
PURPLE FOR RECLAIMED WATER MAIN), A MINIMUM OF FOUR (4) FEET ABOVE GRADE. ALL VALVES
UNDER CONSTRUCTION ARE TO REMAIN CLOSED DURING CONSTRUCTION.
56.ALL PIPE AND STRUCTURES SHALL BE LAID IN THE DRY TRENCH TO THE ELEVATIONS AND SLOPE SHOWN ON THE CONSTRUCTION DRAWINGS. LASER EQUIPMENT SHALL BE USED TO PROVIDE LINE AND GRADE.
THE LASER EQUIPMENT SHALL HAVE A SLOPE INDICATOR TO FACILITATE CHECKING BY BOTH THE PIPE LAYING FOREMAN AND THE CITY ENGINEER. A ZERO TOLERANCE FOR ERRORS IN LINE AND GRADE WILL BE ALLOWED. TOLERANCE FOR DEFLECTION SHALL BE BASED BY INDUSTRY STANDARDS UNLESS OTHER
WISED SPECIFIED.
57.ALL BACKFILL SHALL BE COMPACTED TO NOT LESS THAN 95% OF MAXIMUM DRY DENSITY AS MEASURED BY AASHTO T-180 METHOD 'D' TEST (MODIFIED PROCTOR) IN OPEN AREAS AND TO NOT LESS THAN 98% MAXIMUM DRY DENSITY AS MEASURED BY AASHTO T-180 METHOD 'D' TEST (MODIFIED PROCTOR) UNDER
ASPHALT OR CONCRETE PAVEMENT AND WITHIN 3-FT OF PAVEMENT. ALL SOIL TESTING TO BE
CONDUCTED BY THE COUNTY, AND/OR THE CITY OF MAITLAND FOR LOCATION 3. THE CONTRACTOR
SHALL PROVIDE ALL REASONABLE ASSISTANCE DURING SOIL TESTING.
58.THE CONTRACTOR SHALL BACKFILL UTILITY TRENCHES EACH EVENING AND SHALL LAY NO MORE THAN ONE SECTION OF SEWER, STRUCTURE TO STRUCTURE (INCLUDING LATERAL CONNECTIONS), BEFORE RETURNING TO BACKFILL, COMPACT THE SUBGRADE AND INSTALL THE BASE WHERE APPLICABLE. UPON
COMPLETION OF THE WORK, THE LINES SHALL BE CLEANED, WITH ALL DEBRIS REMOVED AT
DOWNSTREAM MANHOLE. EACH SECTION OF SANITARY PIPE WILL BE TV INSPECTED BY THE CITY TO INDICATE ANY PIPE DEFECTS. BELLIES OR OTHER DEFORMITIES WILL BE RE-LAID TO PROVIDE THE
CORRECT LINE AND GRADE. OCU WILL BILL THE CONTRACTOR DIRECTLY FOR TV RE-INSPECTION PROVIDED BY THE COUNTY (PER LINEAR FOOT), IF THE LINE FAILS THE INITIAL INSPECTION. ALL MANHOLES SHALL BE EXAMINED FOR PROPER GRADE AND WATER TIGHTNESS. THE CONTRACTOR SHALL ASSIST THE ENGINEER BY PROVIDING ALL INSPECTION ASSISTANCE AS REQUIRED. THE CONTRACTOR SHALL MAKE NOTE OF ANY CORRECTIONS REQUIRED AND SHALL PERFORM ALL REMEDIAL ACTIONS PRIOR TO THE FINAL ACCEPTANCE BY THE RPR. THE ASPHALT SHALL BE PLACED AFTER THE PIPE WORK
AND TESTING ARE COMPLETED AND ACCEPTED BY THE COUNTY.
59.THE OWNER SHALL PROVIDE THE SERVICES OF A TESTING LABORATORY TO DETERMINE WHETHER THE REQUIREMENTS FOR MATERIALS SPECIFICATIONS ARE MET. THE CONTRACTOR SHALL GIVE THE RPR A MINIMUM OF 48 HOURS NOTICE WHEN REQUESTING FIELD TESTS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER 48 HOURS BEFORE STARTING ANY ACTIVITY THAT REQUIRES TESTING. 48 HR NOTIFICATION
SHALL ALSO BE PROVIDED TO THE CITY OF MAITLAND FOR LOCATION 3.
60.THE CONTRACTOR MAY BE ALLOWED TO FURNISH AND PLACE EXCAVATABLE FLOWABLE FILL AS A NO ADDITIONAL COST ALTERNATIVE TO BACKFILLING AND COMPACTING SOILS AS APPROVED BY THE
ENGINEER AND THE JURISDICTIONAL AUTHORITY RESPONSIBLE FOR THE RIGHT-OF-WAY.
61.BEFORE A CONNECTION IS TO BE MADE TO AN EXISTING PIPE OR MANHOLE, THE CONTRACTOR SHALL EXCAVATE THE AREA TO VERIFY THE TYPE, SIZE, ELEVATION, AND CONDITION OF THE PIPE AND/OR MANHOLE, AND OBTAIN THE ENGINEER'S APPROVAL FOR THE PROPOSED CONNECTION METHOD, UNLESS
OTHERWISE DETAILED IN THE SPECIFICATIONS OR DRAWINGS.
62.LATERALS SHALL BE BURIED BETWEEN THREE (3) AND FIVE (5) FEET BELOW THE FINISH GRADE AT THE RIGHT OF WAY LINES. CLEANOUTS SHALL BE LOCATED AS CLOSE AS PRACTICAL TO THE R/W LINE, AS APPROVED BY THE ENGINEER. THE LOCATION OF LATERALS SHOWN ON PLANS IS APPROXIMATE. IF THERE IS NO EXISTING LATERAL, THE CONTRACTOR SHALL COORDINATE FINAL LOCATION WITH PROPERTY OWNER PRIOR TO CONSTRUCTION. THE LOCATION OF LATERALS SHALL BE MARKED WITH AN "X" ON THE TOP OF THE CURB, SIDEWALK OR EDGE OF PAVEMENT IF NO CURB OR SIDEWALK EXISTS.
63.AVOID PLACEMENT OF CLEANOUTS IN DRIVEWAYS AND OTHER PAVED AREAS UNLESS OTHERWISE INDICATED IN THE DRAWINGS, OR IF DIRECTED BY THE RPR TO DO SO. IN THESE LOCATIONS ALL CLEANOUTS SHALL BE H20 TRAFFIC LOAD RATED WITH METAL LOCKABLE COVERS STAMPED WITH THE
WORD "SEWER".
64.USE EXTREME CAUTION WHEN EXCAVATING OR CONNECTING TO ASBESTOS CEMENT PIPE. THE CONTRACTOR WILL BE REQUIRED TO SUPPLY TRUCKS CAPABLE OF PUMPING OUT THE PUMP STATION UPSTREAM FROM BREAKS OR CONNECTION POINT. WHEN CONNECTING TO ASBESTOS CEMENT WATER MAIN OR FORCE MAIN THE CONTRACTOR IS REQUIRED TO REPLACE ANY DAMAGED LENGTHS OF PIPE.
THE AMOUNT OF REPLACED PIPE WILL BE DETERMINED BY THE ORANGE COUNTY UTILITIES INSPECTOR.
65.UNDER NO CIRCUMSTANCE SHALL THE ACTIVITIES OF THE CONTRACTOR OR HIS SUBCONTRACTORS CAUSE ANY INTERRUPTIONS TO THE SERVICE OR OPERATION OF EXISTING UTILITIES WITHOUT WRITTEN AUTHORIZATION FROM AN AUTHORIZED REPRESENTATIVE OF THE UTILITY COMPANY OR OWNER. ANY
PIPING OR OTHER UTILITIES WHICH CAN BE REMOVED DURING CONSTRUCTION WITHOUT UNDUE
INTERRUPTION OF SERVICE MAY BE REMOVED AND REPLACED BY THE CONTRACTOR WITH THE
PERMISSION OF THE ENGINEER AND THE UTILITY OWNER. CONTRACTOR SHALL COPY ENGINEER OF ALL
CORRESPONDENCE WITH UTILITY OWNER.
PUBLIC SIDEWALK CURB RAMPS
66.CONTRACTOR SHALL CONSTRUCT SIDEWALK CURB RAMPS CONFORMING TO FDOT INDEX 522-002 AND
ADA STANDARDS AT ALL INTERSECTIONS IMPACTED BY THE UTILITY CONSTRUCTION AND WHERE TECHNICALLY FEASIBLE. THE PAY ITEM SUMMARY INCLUDES A QUANTITY OF ADA RAMPS EQUAL TO THE
MAXIMUM NUMBER ANTICIPATED WITHOUT A DETAILED TRAFFIC ANALYSIS.
ACCESS AND MAINTENANCE OF TRAFFIC
67.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ADEQUATE
TRAFFIC CONTROL DEVICES AND BARRIERS, FOR THE PROTECTION OF VEHICLES, PEDESTRIANS AND THE WORKERS. THE COST OF TRENCH BOXES IF REQUIRED BY TO IMPLEMENT THE APPROVED M.O.T.
PLAN, SHALL BE INCLUDED IN THE UNIT PRICE FOR UTILITY CONSTRUCTION. ALL WORK SHALL BE IN ACCORDANCE WITH THE F.H.W.A. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES AND F.D.O.T.
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, LATEST EDITION AND REVISION, AND MEET
WITH THE APPROVAL OF ORANGE COUNTY PUBLIC WORKS DEPARTMENT, THE CITY OF MAITLAND
(LOCATION 3), AND FDOT TRAFFIC ENGINEERING IF WORKING IN THE FDOT RIGHT OF WAY.
68.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSURING EACH EMPLOYEE SUPERVISING THE SELECTION AND PLACEMENT OF M.O.T. CONTROL DEVICES SHALL BE PROPERLY TRAINED AND CERTIFIED BY ATTENDING AND SUCCESSFULLY COMPLETING A FDOT APPROVED MOT COURSE. THE TRAINING SHALL BE AT A LEVEL APPLICABLE TO THE EMPLOYEE'S LEVEL OF INVOLVEMENT. ALL M.O.T.
CERTIFICATIONS SHALL BE PROVIDED BY THE CONTRACTOR.
69.PEDESTRIAN CONTROL SHALL BE MAINTAINED IN ACCORDANCE WITH FDOT INDEX 102-660. PEDESTRIAN CONTROL SHALL BE MAINTAINED ON ONE SIDE OF THE ROAD AT ALL TIMES. IF UNABLE TO DO SO, THE CONTRACTOR SHALL PROVIDE TEMPORARY WALKWAYS, BOARDWALKS, AND/OR TEMPORARY CONCRETE
SIDEWALK.
70.ALL SIGNS AND TRAFFIC CONTROL DEVICES SHALL BE NEW OR LIKE NEW CONDITION. ALL SIGNS SHALL BE POST MOUNTED UNLESS OTHERWISE INDICATED. EXISTING REGULATORY AND WARNING SIGNS ARE TO BE MAINTAINED AT ALL TIMES UNLESS OTHERWISE NOTED. CHANNELING DRUMS SHALL BE USED ON
NEWLY PAVED ROADWAYS. WATER FILLED BARRIER SHALL BE INSTALLED PER MANUFACTURERS
SPECIFICATIONS. DURING NON-WORKING HOURS, NO EQUIPMENT, VEHICLES OR MATERIAL SHALL BE PARKED OR STORED WITHIN THE CLEAR ZONE OF A ROADWAY OPEN TO VEHICULAR TRAFFIC. ON STREET PARKING IS FOR THE GENERAL PUBLIC AND SHALL NOT BE USED FOR ANY OF THE FOLLOWING:
CONTRACTOR OR SUBCONTRACTOR PARKING, CONSTRUCTION STAGING, TRUCK STAGING, STORING OF
MATERIALS, ET. DELIVERY TRUCKS SHALL NOT BLOCK TRAFFIC.
71.CONTRACTOR TO COMPLETE HIS WORK AT THE END OF EACH DAY AND REOPEN SIDEWALKS FOR PUBLIC USE. SIDEWALKS SHALL CONSIST OF A STABILIZED ASPHALTIC SURFACE, OR EQUAL, SUITABLE FOR PUBLIC FOOT TRAFFIC. MATERIAL TO BE USED SHALL BE APPROVED BY THE COUNTY PRIOR TO
INSTALLATION.
EMERGENCY AND SPILLS
72.IN THE EVENT OF A MAIN BREAK, SPILL OR OTHER EMERGENCY ASSOCIATED WITH ORANGE COUNTY
UTILITY LINES, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY ORANGE COUNTY UTILITY DISPATCH
(407) 836-2777 ANYTIME 24/7. THE CONTRACTOR SHALL PROVIDE TANKERS TO IMMEDIATELY CLEAN UP ANY WASTEWATER SPILLS. THE CITY OF MAITLAND'S APOPKA DISPATCH (407-539-6262) SHALL ALSO BE
IMMEDIATELY NOTIFIED OF ANY SPILLS AT LOCATION 3.
73.THE CONTRACTOR SHALL PROVIDE A WEATHERPROOF ENCLOSURE CONTAINING A LEGIBLY AND ACCESSIBLE LIST OF EMERGENCY CONTACTS AND PHONE NUMBERS. THIS LIST SHALL BE MAINTAINED
AND ACCESSIBLE AT ALL TIMES THROUGH THE DURATION OF THE PROJECT.
74.ALL DAMAGE TO ORANGE COUNTY MAINS SHALL BE REPAIRED IMMEDIATELY BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. IF THE REPAIR IS NOT DONE IN A TIMELY MANNER, AS DETERMINED BY
THE ORANGE COUNTY UTILITY INSPECTOR, ORANGE COUNTY MAY PERFORM REPAIRS AND THE
CONTRACTOR WILL BE CHARGED FOR SAID REPAIRS.
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
DRAWING NO.:LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
UNIVERSITY SHORES- PACKAGE 4
³
KEY MAPS
G 400
SA 3886 - ANDREW PLACE - SHEET C-1
NTS SA 3890- BRADFORD PARK- SHEET C-2
NTS
SA 3891 - LAKE IRMA ESTATES - SHEET C-3
NTS
SA 3843 - PINEWOOD VILLAGE - SHEET C-4
NTS
128200 Rectangle
128200 Rectangle
128200 Rectangle
128200 Rectangle
128200 Typewritten Text
128200 Text Box
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
DRAWING NO.:LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
UNIVERSITY SHORES- PACKAGE 4
³
KEY MAPS
G 500
SA 3695- ALLISON OAKS - SHEETS C-5 AND C-6
NTS
SA F3166- HARBOR EAST - SHEETS C-5 AND C-6
NTS
128200 Rectangle
Rectangle
DATE
38860000
38860005
38860006
38860001
38860003
38860002
University Blvd
Bi bb
L n
La ke
M ira
D r
Larwin Ln
Belter Dr
Hall Rd
Buckley Ct
Spencer Ct
Weep ing W illo w W ay
M uz an te
C t
Br oa d M ea do w C t
8''
PVC FM (1
4''
PVC FM (1
8'' PVC FM (34565)
8'' PVC FM (34565)
8'' P
VC
F
M (1
4'' PVC FM (115)
REV DESCRIPTION
DRAWN BY: X
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
DRAWING NO.:LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
UNIVERSITY SHORES- PACKAGE 4
³0 400 Feet
SA 3886 - ANDREW PLACE
Legend
Pump Station Subarea (SA)
&- Pump Station
Force Main
Gravity Main !( Sewer Manhole
Sewer Lateral L Gravity Main Line
C Gravity Main Clean
_̂ Gravity Main Repairs
R Gravity Main Replace
Gravity Main Descale & LineDLLateral Line Repair
!ôR Manhole R/R
C -1
38900059
38900051
38900041
3890004338900044
38900063
38900005
38900028
38900031
38900054
38900055
38900062
38900037
38900002
38900027
38900032
38900047
38900060
38900003
38900033
38900018
38900020
38900023 3890000838900007
38900061
38900004
38900010
38900025
3890005038900048
38900056
38900045
38900042
38900064
38900029
38900011 38900014
38900030
38900024
38900001
38900012
38900015
38900017
38900022
38900058
38900053
38900006
38900000
38900038
38900013
38900021
38900057
38900052
38900049
38900046
38900035
38900034
38900016
38900019
38900026
University Blvd
Port Said St
La ke
M ira ge B lv d
La ke
M ira
D r
Georgeann St
Q ue ni ta
D r
Sidon St
Te ni ta D r
Pickw ick D r
Woodsworth Dr
C oo l W at er C t
Lake Waunatta Dr
Brookway St
Donna Lynn Ln
Waldorf Ct
Shalace Ct
Guild ford
CtBe nt fo rd
C t
Whistlewing Ct
University Garden Dr
Yacht C t
Waunaqua Dr
N M ira Blvd
W ic kl ow
C ir
Deville Ct
Waterglow Ct
Riviera Shore Ct
Lake Mira Ct
Woodfare Ct
W in gb ow
C t
Marbella View Ct
C ap et ow n D r
W in dw ay
C t
W inbrook Ln
Fa lle n Pi ne C t
W in df al l C t
Active
Active
Active
Active
F3166
10131
4'' PVC FM (384)
'' P
VC
F
M (7
8)
12'' PVC FM (34565)
4' ' P
VC
F
M (3
4'' PVC FM (384)
12'' PVC FM (7258)
REV DESCRIPTION
DRAWN BY: X
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
UNIVERSITY SHORES - PACKAGE 4
SA3890 - BRADFORD PARK³0 400
Feet
Legend
Pump Station Subarea (SA)
&- Pump Station
Force Main
Gravity Main !( Sewer Manhole
Sewer Lateral L Gravity Main Line
C Gravity Main Clean
_̂ Gravity Main Repairs
R Gravity Main Replace
Gravity Main Descale & LineDLLateral Line Repair
!ôR Manhole R/R
389000
3890003
3890004
389000
DRAWING NO.:
C-2
38910011
38910004
38910009
38910014
38910003
3891001238910006
38910008
38910015
38910005
38910000
38910010
38910013
38910007
38910001
38910002
Bibb Ln
University Blvd
Sidon St
La ke
M ira
D r
N E co nl oc kh at ch ee T rl
Belter Dr
Irm a
Sh or es D r
Larwin Ln
Port S aid St
O ra ng e
La ke
D r
Port S im bo r A ve
Spencer Ct
M uz an te
C t
Port Sudan Ct
Lake Mira Ct
Bu ck le y
Ct
Littleton CtTa m ar is k W ay
10438
12'' P
VC FM (3
4565)
8' ' P
VC
F
M (1
8'' PVC FM (10527)
4'' PVC
FM
(2032)
4''
PVC FM (1
4'' PVC FM (45165)
8' ' D
IP
F
M (1
8'' P
VC
F
M (1
8' ' P
VC
F
M (1
12'' P
VC FM (3
4565)
8' ' P
VC
F
M (1
8'' PVC FM (10527)
4'' PVC FM (2032)
4'' PVC FM (115)
8''
PV
C
FM
(1
REV DESCRIPTION
DRAWN BY: X
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
DRAWING NO.:LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
SA3891 - LAKE IRMA ESTATES
UNIVERSITY SHORES - PACKAGE 4
³0 400 Feet
Legend
Pump Station Subarea (SA)
&- Pump Station
Force Main
Gravity Main !( Sewer Manhole
Sewer Lateral L Gravity Main Line
C Gravity Main Clean
_̂ Gravity Main Repairs
R Gravity Main Replace
Gravity Main Descale & LineDLLateral Line Repair
C - 3
39430001
39430002
39430011 39430012
39430010 39430008 39430007
39430006
39430005
39430000
3943000339430004
39430009
Alveron Ave
Baja Blvd
Bates Rd
Bucksaw Dr
Pa te l D r
N C hi ck as aw
T rl
R ol lin g
Lo g
D r
Vi a
D os
C ro w n
Je w el C t
Auburn Cir
Al le y
Via U no
W ed ge C t
Lo gg er C t
4'' PVC FM (-1)4'' PVC FM (-1)
REV DESCRIPTION
DRAWN BY: X
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
DRAWING NO.:LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
UNIVERSITY SHORES
SA3943 - PINEWOOD VILLAGE³0 400
Feet
Legend
Pump Station Subarea (SA)
&- Pump Station
Force Main
Gravity Main !( Sewer Manhole
Sewer Lateral L Gravity Main Line
C Gravity Main Clean
_̂ Gravity Main Repairs
R Gravity Main Replace
Gravity Main Descale & LineDLLateral Line Repair
C - 4
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
UNIVERSITY SHORES - PACKAGE 4
SA3965 - ALLISON OAKS³0 400
Feet
Legend
Pump Station Subarea (SA)
&- Pump Station
Force Main
Gravity Main !( Sewer Manhole
Sewer Lateral L Gravity Main Line
C Gravity Main Clean
_̂ Gravity Main Repairs
R Gravity Main Replace
Gravity Main Descale & LineDLLateral Line Repair
!ôR Manhole R/R
DRAWING NO.:
C- 5
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
DRAWING NO.:LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
UNIVERSITY SHORES - PACKAGE 4
SA3965 ALLISON OAKS³0 400
Feet
Legend
Pump Station Subarea (SA)
&- Pump Station
Force Main
Gravity Main !( Sewer Manhole
Sewer Lateral L Gravity Main Line
C Gravity Main Clean
_̂ Gravity Main Repairs
R Gravity Main Replace
Gravity Main Descale & LineDLLateral Line Repair
C - 6
F3166
10041
F3166
10131
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
UNIVERISTY SHORES - PACKAGE 4
SAF3166 - HARBOR EAST³
Legend
L
C
R
DL
!ôR
C - 7
38920073
F3166009
F31660000F31660084
F31660088
F31660087
F31660085
Port Said St
T C
U B lv d
Pamlico St
Esperanza St
La ke
J ea n D r
Dominguin St
C am ba y
Av e
Vi a
D os
N C hi ck as aw
T rl
C apetow n D r
S M
U C t
La ke w oo d P oi nt e D r
Bl ue br oo k D r
R iv er br oo k
D r
Ve ra va l A ve
M I
T St
Calcutta Ave
Castinango St
Park Promenade Dr
S M
U B lv d
Singapore Ct
Laurel Springs Dr
R os eb ud
L n
Villanova St
Vi a
U no
C ra ne S tra nd
D r
Crushed Pepper Ave
Aden Ct
Sh el l C ov e Ln
University Garden Dr
Georgia Tech St
Far View Cir
Georgia Peach Dr
C he di st on C ir
Tumeric Ct
B Y
U C t
Sw ee t G ra ss C ir
Br an dy w oo d
C ir
W oo dr un
C t Captiva Ct
Irm as to ne
W ay
Bibb Ln
Annatto Cv
Port Sim bor Ave
F3166
Active
Active
Active
10041
3893A
F3166
10042
F3110
12'' PVC FM (34565)
4' ' P
VC
FM
(3
4'' PVC FM (384)
4'' PVC FM ()
4'' PVC FM (10384)
4' ' D
IP
F
M (3
0)
4'' PVC FM (3080)
12'' PVC FM
(34565)
4'' PVC
FM
(31651)
4'' PVC FM (384)
4'' PVC FM (10384)
REV DESCRIPTION
DRAWN BY: X
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
DRAWING NO.:LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
UNIVERISTY SHORES - PACKAGE 4
SAF3166 - HARBOR EAST³0 400
Feet
Legend
Pump Station Subarea (SA)
&- Pump Station
Force Main
Gravity Main !( Sewer Manhole
Sewer Lateral L Gravity Main Line
C Gravity Main Clean
_̂ Gravity Main Repairs
R Gravity Main Replace
Gravity Main Descale & LineDLLateral Line Repair
!ôR Manhole R/R
38920073892007
389200389200
389200
389200 389200
389200
389200
389200
389200 389200389200
389200 389200
389200 389200
389200 389200
389200
389200
389200
389200
389200
389200
389200
389200
389200389200
389200
389200
F316600
F316600
C - 8
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
DRAWING NO.:LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
CD-1
UNIVERSITY SHORES - PACKAGE 4
SITE CIVIL DETAILS
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
DRAWING NO.:LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
CD-2
UNIVERSITY SHORES - PACKAGE 4
SITE CIVIL DETAILS
ORANGE COUNTY UTILITIES
STANDARDS AND CONSTRUCTION SPECIFICATIONS MANUAL
STANDARD DRAWINGS
FIGURE RR-09
GRAVITY R/RAPPENDIX A
DATE: January 20, 2012
CONTINUOUS 1-1/2" x 1/2"
BUTYL MASTIC STRIP
(TYP)
PACK w/ GROUT
COMPRESSION BANDS
(TYP)
GRAVITY
SEWER PIPE
HDPE
EXTERNAL BOOT
HDPE LINER
WELD BOOT
CIRCUMFERENTIALLY
TO HDPE LINER
INTERIOR EXTERIOR
FLEXIBLE PIPE CONNECTION
TO HDPE LINED MANHOLE
NOTES:
1. POUR HYDRAULIC CHANNAL AFTER SUCCESFUL
TESTING OF HDPE WELDS.
Rectangle
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
DRAWING NO.:LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
CD- 3
APPENDIX A STANDARD DRAWINGS
ORANGE COUNTY UTILITIES
STANDARDS & CONSTRUCTION
SPECIFICATIONS MANUAL
PRECAST CONCRETE MANHOLE
10/10/2021
FIGURE A301
1. DROP CONNECTIONS ARE REQUIRED WHENEVER INVERT OF INFLUENT SEWER IS 24-IN
OR MORE ABOVE THE INVERT OF THE MANHOLE. SEE MANHOLE FIG A302-2.
2. ECCENTRIC CONE DESIGN MAY BE USED FOR CONFLICT RESOLUTION WITH OCU
APPROVAL.
3. A FLOW CHANNEL SHALL BE CONSTRUCTED INSIDE MANHOLE TO DIRECT INFLUENT
INTO FLOW STREAM IN ACCORDANCE WITH FIG A303.
4. LIFT HOLES THROUGH STRUCTURE ARE NOT PERMITTED.
5. HEAT SHRINK WRAP FOR ALL BARREL SECTION JOINTS SHALL BE A MIN 9-IN WIDTH AND
A MIN 17-IN WIDTH WRAP ON THE CORBEL SECTION, RISER RINGS AND RING AND
COVER.
6. HDPE ADJUSTING RINGS MAY BE SUBSTITUTED FOR BRICK RISERS.
7. SECTION HEIGHTS VARY AS REQUIRED, AND AS AVAILABLE, FROM APPROVED
MANUFACTURERS LISTED IN APPENDIX D AND IN COMPLIANCE WITH ASTM C478.
8. MANHOLE SHALL BE COATED OR LINED IN ACCORDANCE WITH SECTIONS 2310 & 3119.
INSIDE WALL
PRE-PRIMED JOINT
SURFACES (TYP)
OUTSIDE WALL
2" MIN JOINTING MATERIAL,
APPLIED TO BOTH LIPS
SQUEEZE-OUT, MIN 0.50"
INTERIOR AND EXTERIOR
(TYP)
SET COVERS FLUSH IN
PAVED AREAS
MANHOLE FRAME & COVER
(SEE STANDARD DETAIL A305)
FRAMES BEDDED IN
MORTAR
2 COURSES OF BRICK (MIN)
4 COURSES (MAX) OR MIN 5"
TO MAX 10" HDPE
ADJUSTING RING
0.8D (EFFLUENT PIPE DIA)
CONCRETE WITH CRYSTALLINE
WATER PROOFING ADMIXTURE
SHRINK SEAL (TYP) (SEE
NOTE 5)
COATING OR LINER
(SEE NOTE 8)
3' MAX
EXTERNAL MANHOLE HEAT
BENCHING (2" MIN)
48" MIN
6" MIN
24"
8"
1' MIN
9" M
IN
9"
8"
6" MIN
12" MIN
2"
FDOT #57 STONE IN ALL
DIRECTIONS (MIN 9-IN)
WRAPPED IN GEOFRABRIC
APPENDIX A STANDARD DRAWINGS
ORANGE COUNTY UTILITIES
STANDARDS & CONSTRUCTION
SPECIFICATIONS MANUAL
GRAVITY MANHOLE CONNECTION
10/10/2021
FIGURE A302-1
1. AN OUTSIDE DROP CONNECTION SHALL BE REQUIRED FOR ALL INFLUENT LINES WHICH
HAVE AN INVERT 2-FT OR MORE ABOVE THE MANHOLE INVERT. SEE FIG A302-2.
2. CONTRACTOR SHALL COORDINATE THE PRESENCE OF UTILITIES INSPECTOR DURING
EXCAVATION, CORING AND CONNECTIONS TO EXISTING MANHOLES.
3. ALL PIPE CONNECTIONS SHALL HAVE A MINIMUM OF 12-IN SEPARATION FROM ALL
JOINTS AND CORES.
4. PIPE SHALL PROTRUDE INTO MANHOLE 2-IN TO 4-IN. THE CONTRACTOR SHALL BEVEL
MUD FROM EDGE OF PIPE TO WALL.
5. CONNECTIONS ON EXISTING MANHOLES, REFER TO SECTION 3113 FOR EXCAVATIONS
FOR STRUCTURES.
6. MANHOLE SHALL BE COATED OR LINED IN ACCORDANCE WITH SECTIONS 2310 & 3119.
PVC
PVC
PRECAST MANHOLE
WALL
PRECAST
MANHOLE WALL
STAINLESS STEEL
PIPE CLAMP
RESILIENT CONNECTOR
(PER APPENDIX D)
STAINLESS STEEL BAND
CAST-IN-PLACE SEAL
(PER APPENDIX D)
"M
IN
(S
E E
N O
TE
3)
"M
IN
(S
E E
N O
TE
3)
LINER (SEE NOTE 6)
CONNECTION
(SEE ALL NOTES)
(SEE NOTE 4)
APPENDIX A STANDARD DRAWINGS
ORANGE COUNTY UTILITIES
STANDARDS & CONSTRUCTION
SPECIFICATIONS MANUAL
GRAVITY MANHOLE CONNECTION - OUTSIDE DROP
10/10/2021
FIGURE A302-2
2"
1. DROP PIPE AND FITTINGS SHALL BE OF EQUAL SIZE AND MATERIAL AS THE INFLUENT
SEWER.
2. AN OUTSIDE DROP CONNECTION SHALL BE REQUIRED FOR ALL INFLUENT LINES WHICH
HAVE AN INVERT 2-FT OR MORE ABOVE THE MANHOLE INVERT.
3. CONTRACTOR SHALL COORDINATE THE PRESENCE OF UTILITIES INSPECTOR DURING
EXCAVATION, CORING AND CONNECTIONS TO EXISTING MANHOLES.
4. FORM AND POUR CONCRETE TO BOTTOM OF TEE. INSTALL A MINIMUM OF TWO (2)
U-SHAPE REBAR MIN 8-IN BELOW TEE. INSTALL GRAVITY MAIN, FORM & CAP OFF W/
CONCRETE MIN 12-IN ABOVE INFLUENT PIPE.
5. ALL PIPE CONNECTIONS SHALL HAVE A MINIMUM OF 12-IN SEPARATION FROM ALL
JOINTS AND CORES.
#4 REBAR
@ 8" OC 30" x 30"
PAD (MIN)
OUTSIDE
DROP
#4 U-SHAPE
REBAR (SEE
NOTE 4)
M
IN
INFLUENT
SEWER
DROP PIPE
(TYP)
BASE
6"
M
IN
6"6"
TEE
(TYP)
90° BEND
90°
BEND
EXISTING BASE
DRILL & EPOXY #4
DOWELS @ 8" OC
DROP
PIPE
CONC ENCASEMENT
INFLUENT
SEWER (SEE
NOTE 2)
PRECAST MANHOLE WALL
30"
COLD JOINT
#4 REINFORCING
APPENDIX A STANDARD DRAWINGS
ORANGE COUNTY UTILITIES
STANDARDS & CONSTRUCTION
SPECIFICATIONS MANUAL
GRAVITY MANHOLE FLOW CHANNELS
10/10/2021
FIGURE A303
1. ALL PIPE CONNECTIONS SHALL BE IN ACCORDANCE WITH FIGS A302-1, A302-2, GRAVITY
MANHOLE CONNECTIONS
2. ALL BENCH WORK SHALL SLOPE TOWARDS THE INVERT AND BE A MIN 2-IN PER FOOT
SLOPE.
MIN 2500 PSI CONCRETE
(PORTLAND CEMENT
TYPE II) (TYP)
APPENDIX A STANDARD DRAWINGS
ORANGE COUNTY UTILITIES
STANDARDS & CONSTRUCTION
SPECIFICATIONS MANUAL
MANHOLE IN NON-PAVED AREA
10/10/2021
FIGURE A304
SANITARY
SEWER
1. MINIMUM CLEARANCE OF 30-IN FREE FROM OBSTRUCTIONS IN ALL DIRECTIONS.
2. AREAS SUPPORTING CONCRETE COLLAR OR SLAB SHALL BE PROPERLY COMPACTED.
3. TOP OF MANHOLE SHALL BE 2-IN ABOVE FINISHED GRADE, CROWN OF ADJACENT
ROADWAY, OR 100 YEAR FLOOD ELEVATION, WHICHEVER IS GREATER.
FIBER MESH OR 4" BAR
CONTINUOUS AROUND
COLLAR. 3" MIN COVER
(TYP)
FINISHED GRADE
2,500 PSI CONCRETE
AROUND MANHOLE
2" M
IN8"
MIN
8"
MIN
7" M
IN
MIN 2,500 PSI
CONCRETE AROUND
MANHOLE
MANHOLE COVER
(SEE FIGURE A305)
LINER AS
REQUIRED
APPENDIX A STANDARD DRAWINGS
ORANGE COUNTY UTILITIES
STANDARDS & CONSTRUCTION
SPECIFICATIONS MANUAL
STANDARD MANHOLE FRAME & COVER
10/10/2021
FIGURE A305
SANITARY
SEWER
1. ONLY APPLIES TO UTILITIES OWNED AND MAINTAINED MANHOLES. "ORANGE COUNTY"
SHALL NOT APPEAR ON PRIVATE MANHOLES.
TWO NON-
PENETRATING
PICK HOLES
RAISED 1.5" LETTERS FLUSH
WITH TOP OF COVER
MACHINED MATING
SURFACES
39"
4.75" MIN
7"
25.75" (STANDARD)
1.
5"
M
IN
24" ± 0.375"
APPENDIX A STANDARD DRAWINGS
ORANGE COUNTY UTILITIES
STANDARDS & CONSTRUCTION
SPECIFICATIONS MANUAL
SERVICE LATERAL
10/10/2021
FIGURE A306-1
1. INVERT OF SERVICE LATERAL SHALL NOT ENTER SEWER MAIN BELOW SPRING LINE.
2. SERVICE LATERAL AND DOUBLE SWEEP TEES SHALL BE CAPPED BY DEVELOPER'S
SITE-WORK CONTRACTOR.
3. TEE & WYE SHALL BE NO SHALLOWER THAN 3-FT AND NO DEEPER THAN 5-FT.
4. LOCATOR BALLS TO BE INSTALLED BY DEVELOPER'S SITE-WORK CONTRACTOR, TWO
PER DOUBLE SERVICE AND ONE PER SINGLE SERVICE AT MINIMUM.
5. ALL FITTINGS SHOWN ARE TO BE INSTALLED.
6. SERVICE CONNECTIONS SHALL BE PERMANENTLY MARKED BY CUTTING AN "S" IN THE
CURB DIRECTLY OVER THE LATERAL.
7. BUILDER'S PLUMBER WILL REMOVE PLUG(S), INSTALL CLEANOUT ON DOUBLE SWEEP
TEE, AND CONNECT SERVICE LATERAL TO HOUSE. NO DIRT OR DEBRIS SHALL ENTER
THE SERVICE LATERAL THROUGHOUT CONSTRUCTION.
SINGLE
LATERAL
(TYP)
DOUBLE
LATERAL
(TYP)
LOCATOR BALL 6"
BELOW TEE (TYP)
(SEE NOTE 4)
BUILDER'S
PLUMBER (TYP)
(SEE NOTE 7)
SPRING LINE
SEWER MAIN
ROTATE
30° (TYP)
TEMP PLUG
(TYP) (SEE
NOTES 2 & 7)
FINISHED
GRADE
STAKE TO SHOW LOCATION
OF TEMPORARY PLUG (TYP)
SLOPE TO TERMINAL DEPTH
@ 1.0% MIN (TYP)
R .O
.W
WYE WITH 6"
BRANCH
6" 45° BEND
SEWER MAIN
WYE WITH 6"
BRANCH
6" 45° BEND
CLEAN-OUT
(TYP)
LOT LINE
DOUBLE
WYE W/ 6"
BRANCH
TEMP PLUG
(SEE NOTES
2 & 7)
S
BUILDER'S
PLUMBER (TYP)
(SEE NOTE 7)
CURB ETCHING
(SEE NOTE 6) (TYP)
3' M
IN
5'
M
AX
(S E
E N
O
TE
3)
S
6" DOUBLE
SWEEP TEE
(TYP)
BUILDER'S
PLUMBER (TYP)
(SEE NOTE 7)
4"-6" BELOW
GRADE (TYP)
R .O
.W
R .O
.W
R .O
.W
APPENDIX A STANDARD DRAWINGS
ORANGE COUNTY UTILITIES
STANDARDS & CONSTRUCTION
SPECIFICATIONS MANUAL
SERVICE LATERAL - PIPE CONFLICT
10/10/2021
FIGURE A306-2
1. GRADE MAX CHANGE TO INSTALL SEWER LATERAL OVER OR UNDER AN EXISTING
CONFLICT.
2. ALL CONFLICT SEPARATIONS LESS THAN THE MINIMUM SHALL NOT BE PERMITTED
UNLESS APPROVED BY THE UTILITIES INSPECTOR.
3. MINIMUM SLOPE SHALL NOT BE LESS THAN 1%.
4. BEND FITTINGS SHALL BE USED TO ENSURE PROPER SEPARATION FROM ALL
HORIZONTAL CONFLICTS.
5. IF A CONFLICT AT THE PROPERTY LINE EXISTS, TWO SINGLE SEWER SERVICES SHALL
BE INSTALLED IN AN APPROVED LOCATION BY UTILITIES.
SLOPE TO
TERMINAL DEPTH
@ 1% MIN
SEWER MAIN
WYE W/ 6"
BRANCH AND
45° BEND
BEND FITTING
(TYP)
FINISHED GRADE
6" MIN
SEPARATION
(SEE NOTE 2)
6" MIN
SEPARATION
(SEE NOTE 2)
SLOPE TO
TERMINAL DEPTH
@ 1% MIN
FINISHED GRADE
EXISTING
CONFLICT
EXISTING
CONFLICT
3' M
IN
3' M
IN
SEWER MAIN
WYE W/ 6"
BRANCH AND
45° BEND
CHECKED BY: X
CAD FILE:
SCALE: 1" = 200'
DRAWING NO.:LINE IS 2 INCHES
AT FULL SIZE
(IF NOT SCALE ACCORDINGLY)
ORANGE COUNTY
UTILITIES DEPARTMENT
ENGINEERING DIVISION
9150 CURRY FORD ROAD ORLANDO, FL. 32825
CD- 4
APPENDIX A STANDARD DRAWINGS
ORANGE COUNTY UTILITIES
STANDARDS & CONSTRUCTION
SPECIFICATIONS MANUAL
BEDDING & TRENCHING - TYPE A
10/10/2021
FIGURE A101
1. INITIAL BACKFILL AND HAUNCHING: SELECT COMMON FILL COMPACTED TO MIN 95% (98%
UNDER PAVEMENT OR FUTURE PAVEMENT) OF THE MAXIMUM DENSITY AS PER AASHTO
T-180.
2. TRENCH BACKFILL: COMMON FILL COMPACTED TO MIN 95% (98% UNDER PAVEMENT OR
FUTURE PAVEMENT) OF THE MAXIMUM DENSITY AS PER AASHTO T-180.
3. PIPE BEDDING UTILIZING SELECT COMMON FILL IN ACCORDANCE WITH "TYPE B" BEDDING
AND TRENCHING DETAIL MAY BE REQUIRED AS DIRECTED BY UTILITIES.
4. 15-IN MAX. (12-IN MIN.) FOR PIPE DIAMETER LESS THAN 24-IN AND 24-IN MAX (12-IN MIN)
FOR PIPE DIAMETER 24-IN AND LARGER.
5. WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION.
DEWATERING AS REQUIRED.
6. ALL PIPE SHALL BE INSTALLED WITH BELL FACING UPSTREAM TO THE DIRECTION OF THE
FLOW.
7. FINAL RESTORATION IN IMPROVED AREAS SHALL BE IN COMPLIANCE WITH ALL
APPLICABLE REGULATIONS OF GOVERNING AGENCIES. SURFACE RESTORATION WITHIN
ORANGE COUNTY RIGHT-OF-WAY SHALL COMPLY WITH REQUIREMENTS OF
RIGHT-OF-WAY UTILIZATION REGULATIONS AND ROAD CONSTRUCTION SPECIFICATIONS.
8. FOR GRAVITY SEWER, THE FIRST LIFT SHALL BE PLACED TO THE SPRING LINE OF THE
PIPE AND COMPACTED BY HAND TAMP.
9. CONTRACTOR SHALL USE BEDDING AND TRENCHING - TYPE B DETAIL FOR OVER
EXCAVATION AND WHEN UNSUITABLE MATERIALS ARE ENCOUNTERED IN THE
EXCAVATION.
TRENCH WIDTH
VARIES
W/ PIPE SIZE
PIPE O.D.
(SEE NOTE 4)
COMMON FILL
12" (TYP)
SELECT
COMMON FILL
UNDISTURBED
EARTH
(SEE NOTE 3)
HAUNCHING
(SEE NOTE 8) (S
EE
N
O
TE
1)
INITIAL
BACKFILL
TR
E
N C
H
BA
C K
FI
LL
(S E
E N
O
TE
2)
"L
IF
TS
M
AX
IM
U M
FINISHED GRADE
MIN 24" WATER LEVEL
1.5
(SEE NOTE 5)
APPENDIX A STANDARD DRAWINGS
ORANGE COUNTY UTILITIES
STANDARDS & CONSTRUCTION
SPECIFICATIONS MANUAL
BEDDING & TRENCHING - TYPE B
10/10/2021
FIGURE A102
SELECT
COMMON FILL
BEDDING MATERIAL
(SEE NOTE 10) BEDDING
(SEE NOTES 9 & 10)
HAUNCHING
(SEE NOTE 8)
(S
EE
N O
TE
3)
INITIAL BACKFILL
(SEE NOTE 1)
TR
E
N C
H
BA
C K
FI
LL
(S E
E N
O
TE
2)
"L
IF
TS
M
AX
12" (TYP)
PIPE O.D.
1. INITIAL BACKFILL: SELECT COMMON FILL COMPACTED TO MIN 95% (98% UNDER PAVEMENT
OR FUTURE PAVEMENT) OF THE MAXIMUM DENSITY AS PER AASHTO T-180.
2. TRENCH BACKFILL: COMMON FILL COMPACTED TO MIN 95% (98% UNDER PAVEMENT OR
FUTURE PAVEMENT) OF THE MAXIMUM DENSITY AS PER AASHTO T-180.
3. PIPE BEDDING UTILIZING SELECT COMMON FILL IN ACCORDANCE WITH "TYPE B" BEDDING
AND TRENCHING DETAIL MAY BE REQUIRED AS DIRECTED BY UTILITIES.
4. 15-IN MAX. (12-IN MIN.) FOR PIPE DIAMETER LESS THAN 24-IN AND 24-IN MAX (12-IN MIN) FOR
PIPE DIAMETER 24-IN AND LARGER.
5. WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION. DEWATERING
AS REQUIRED.
6. ALL PIPE SHALL BE INSTALLED WITH BELL FACING UPSTREAM TO THE DIRECTION OF THE
FLOW.
7. FINAL RESTORATION IN IMPROVED AREAS SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
REGULATIONS OF GOVERNING AGENCIES. SURFACE RESTORATION WITHIN ORANGE
COUNTY RIGHT-OF-WAY SHALL COMPLY WITH REQUIREMENTS OF R/W UTILIZATION
REGULATIONS AND ROAD CONSTRUCTION SPECIFICATIONS.
8. FOR GRAVITY SEWER, THE FIRST LIFT SHALL BE PLACED TO THE SPRING LINE OF THE PIPE
AND COMPACTED BY HAND TAMP.
9. BEDDING DEPTH SHALL BE 4-IN MINIMUM FOR PIPE DIAMETER UP TO 12-IN AND 6-IN MINIMUM
FOR PIPE DIAMETER 16-IN AND LARGER.
10. DEPTH FOR REMOVAL OF UNSUITABLE MATERIAL SHALL GOVERN DEPTH OF REQUIRED
BEDDING MATERIAL BELOW THE PIPE. UTILITIES SHALL DETERMINE REMOVAL OF
UNSUITABLE MATERIAL TO REACH SUITABLE FOUNDATION IN THE FIELD.
COMMON FILL
FINISHED GRADE
UNDISTURBED
EARTH
1.5
TRENCH WIDTH
VARIES
W/ PIPE SIZE
(SEE NOTE 4)
MIN 24" WATER LEVEL
(SEE NOTE 5)