X-101 Conduit Trench Detail.pdf
PDF 160 KB Posted
- Solicitation number
- 36C26325B0021_0001
About this file
This is an engineering drawing detail for a conduit trench installation as part of a physical access control system upgrade project. The drawing, numbered X-101 and issued on 08/05/2025, was prepared by Valhalla Engineering Group for the Veterans Affairs Health Care System (VAHCS) facility located at 4801 Veterans Drive, St. Cloud, MN 56303, under project number 656-19-324.
The technical drawing provides detailed specifications for trench backfill and concrete work, including specific requirements for conduit placement with 4-inch minimum spacing, 3-foot separation between electrical and telecom lines, #3 rebar concrete ties at 24-inch on-center spacing, and floatable fill or 95% compacted fill materials. The drawing specifies field verification requirements for existing conditions and includes instructions to match existing concrete finishes. This construction detail supports the overall upgrade of the physical access control system infrastructure at the VA medical facility.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 656-19-324 Upgrade PACS Questions_VALHALLA.docx | DOCX document | |
| 36C26325B0021 0001.pdf | ||
| PACS Sitewalk Registration Sheet.pdf | ||
| Site Visit Agenda July 23 2025.docx | DOCX document | |
| Drawings.zip | ZIP file |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TRENCH BACKFILL-CONCRETE1
VERIFY IN FIELD
4" 4"
6" MI
N.
VE
RI
FY
IN
F
IE
LD
3'-0" SEPARATION BETWEEN
ELECTRICAL AND TELECOM LINES
4"
BACKFILL
MATCH EXISTING
CONCRETE FINISH
6" MI
N.
#3 REBAR
CONCRETE
TIE @ 24" O.C.
BETWEEN NEW
AND EXISTING
SLAB
ENE N
4"
6" 6"6" 6"
FLOATABLE
FILL OR 95%
COMPACTED
FILL
Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Drawing Title
750 W HAMPDEN AVE, SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
8/5/2025 8:28:43 AM
X-101
UPGRADE PHYSICAL ACCESS CONTROL
SYSTEM
VAHCS 4801 VETERANS DRIVE, ST CLOUD, MN 56303
656-19-324
N/A
DM ZAM08/05/2025
CONDUIT TRENCH DETAIL
VEG 23.04
Number: Revision: Date:
| Sheets and Views |
| A0.7 |