WT-0295 - Plans.pdf
PDF 19 MB Posted
- Attached to
- Filter Pipe Gallery Improvements
- Solicitation number
- WT-0295
- Issued by
- Oklahoma County, Hobart City, Oklahoma
About this file
This document is a comprehensive bid set for the City of Oklahoma City Water Utilities Trust, specifically for Filter Pipe Gallery Improvements at the Draper Water Treatment Plant. The project (Project No. WT-0295) involves extensive renovations to the existing filter pipe gallery, including removing and replacing drain pipes, Dresser couplings, concrete pipe supports, pipe support hangers, and concrete flume support hangers. The improvements also include HVAC modifications such as installing new supply and exhaust fans, gas-fired unit heaters, and lighting upgrades. The project will involve coating existing pipes, repairing concrete supports, and upgrading electrical systems, with work to be performed in the Filter Building Pipe Gallery.
The bid documents indicate this is an "Issue for Bid" set, suggesting the project is currently in the procurement phase. The scope encompasses electrical, mechanical, and civil work, with detailed specifications for equipment replacement and system upgrades. While specific budget details are not explicitly stated, the comprehensive nature of the improvements suggests a significant capital investment. The project appears to be funded through the Oklahoma City Water Utilities Trust, with work focused on maintaining and modernizing critical infrastructure at the Draper Water Treatment Plant. The bid set includes extensive technical details, equipment schedules, floor plans, electrical and HVAC diagrams, and specific requirements for demolition, installation, and system integration.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Anti Noncollusion Affidavit.pdf | ||
| Business Relationship Affidavit.pdf | ||
| WT-0295- Specs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GE
N
ER
AL
GE
N
ER
AL
N O
TE
S
AN
D
SH
EE
T
IN
DE
X
G-G-02
SD
M M
M M
GB
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig in al
IS
SU
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
RE
VI
SE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 9/3/2025 4:48 PM Plot By: 03761 Filename: N:\WTU\Drawings\WT0295\GN-ALL-SHEET INDEX.dwg
GN
-A
LL
-S
HE
ET
IN
DE
X.
dw g
La st
S av ed : 9
/3 /2
4:
P M
Sa ve d
By : 0
Fi le na m e:
N
W
TU
\D ra w in gs
\W T0
5\
GN
-A
LL
-S
HE
ET
IN
DE
X.
dw g
AC
AD
R el : 2
4.
2s
(L M
S Te ch
ISSUE FOR BID
CI
TY
O F
O
KL
AH
O
M A
CI
TY
W T-
D
RA
PE
R
W
AT
ER
T
RE
AT
M
EN
T
PL
AN
T
FI
LT
ER
P
IP
E
GA
LL
ER
Y
IM
PR
O
VE
M
EN
TS
CO
C2
SE
P
N W th S t., S ui te
O kl ah om a Ci ty , O
K
Ph on e
5)
-7
W eb w w w .fr ee se
.c om
Ce rt ifi ca te o f A ut ho riz at io n:
C
A#
Ex pi ra tio n
Da te
: 0 6/
/2
GENERAL NOTES
1. THE FOLLOWING NOTES ARE GENERAL AND APPLY TO ALL SHEETS OF
THESE CONTRACT DOCUMENTS AS IF THEY WERE WRITTEN IN THEIR
ENTIRETY ON EACH SHEET.
2. EXISTING STRUCTURES, UTILITIES AND PIPING ARE SHOWN FROM
AVAILABLE RECORDS AT THE TIME THIS PLAN WAS PREPARED. THE
CONTRACTOR SHALL BE RESPONSIBLE TO DETERMINE AND VERIFY THE
LOCATION AND DEPTH OF ALL EXISTING STRUCTURES, UTILITIES AND
PIPING WITHIN THE CONSTRUCTION AREA PRIOR TO THE BEGINNING OF
CONSTRUCTION. ANY DAMAGE TO THE EXISTING STRUCTURES, UTILITIES
AND PIPING SHALL BE RESTORED AT NO ADDITIONAL COST TO THE
OWNER.
3. PRIOR TO FABRICATION OF NEW PIPING, INCLUDING SPECIAL FITTINGS
AND EXCAVATION FOR NEW STRUCTURES, ELECTRICAL CONDUIT AND/OR
OTHER ROPOSED UTILITIES, CONTRACTOR SHALL BE RESPONSIBLE FOR
VERIFYING THE LOCATION OF ALL EXISTING PIPING AND UTILITIES IN THE
CONSTRUCTION. AT TIE-IN CONNECTION LOCATIONS, VERIFY EXISTING
PIPING BEFORE FABRICATION OF NEW PIPING. THE CONTRACTOR SHALL
INCLUDE COST IN HIS BID FOR TEMPORARILY RELOCATING AND
REINSTALLING EXISTING UTILITIES AS REQUIRED FOR CONSTRUCTION OF
PROPOSED ITEMS.
4. PIPES SHALL BE ROUTED AS SHOWN UNLESS MINOR REVISIONS ARE
NECESSARY TO AVOID EXISTING PIPES, STRUCTURES, ETC. CONTRACTOR
SHALL BE RESPONSIBLE FOR FURNISHING ALL FITTINGS AND ADAPTERS
REQUIRED TO MAKE THE ROUTING CHANGES. CONTRACTOR SHALL
INCLUDE COST FOR THIS IN THE BID.
5. PROVIDE PIPE, EQUIPMENT, FITTINGS, ADAPTERS, SUPPORTS AND
APPURTENANCES REQUIRED FOR A COMPLETE AND WORKING SYSTEM.
6. PROVIDE RESTRAINED JOINTS AND CONCRETE ENCASEMENT AT ALL
VERTICAL/HORIZONTAL BENDS AND CONCRETE ENCASEMENT SHALL BE AS
SHOWN IN THE STANDARD CIVIL DETAILS.
7. DO NOT EXCEED 75% OF MANUFACTURER'S RECOMMENDED MAXIMUM
DEFLECTION FOR PIPE JOINTS, UNLESS NOTED OTHERWISE.
8. UTILITIES DESIGNATED TO BE DEMOLISHED SHALL BE COMPLETELY
REMOVED, UNLESS OTHERWISE APPROVED BY THE ENGINEER.
9. CONTRACTOR SHALL VERIFY THAT PIPING OR STRUCTURES SHOWN TO BE
ABANDONED OR AS ABANDONED PREVIOUSLY IS NO LONGER IN SERVICE.
LINES IN SERVICE SHALL BE MAINTAINED UNTIL NO LONGER REQUIRED BY
THE OWNER.
10. EXISTING PIPES ABANDONED IN PLACE OR TO BE REMOVED MAY NOT BE
SHOWN. WHERE PIPING TO BE ABANDONED MUST REMAIN IN SERVICE
UNTIL COMPLETION OF OTHER PHASE WORK, AND IF CONFLICTS WITH
NEW PIPING, TEMPORARILY RELOCATE TO MAINTAIN SERVICE.
11. CONTRACTOR SHALL REROUTE THE EXISTING PIPING IF REQUIRED TO
AVOID THE PROPOSED STRUCTURES. THE EXISTING PIPE SHALL REMAIN IN
SERVICE UNTIL NEW PIPING IS READY TO BE PLACED INTO SERVICE.
DOWNTIME SHALL BE A MAXIMUM OF 2 HOURS, UNLESS SPECIFIED IN
THE CONTRACT DOCUMENTS OR SHOWN OTHERWISE. ALL REMAINING
PIPING, WHETHER IN SERVICE OR ABANDONED, SHALL BE NOTED ON THE
RECORD DRAWINGS.
12. PROTECT M.J. HARDWARE FROM BEING ENCASED OR COVERED WITH
CONCRETE ENCASEMENT DURING INSTALLATION OF CONCRETE, UNLESS
NOTED OTHERWISE.
13. THE CONTRACTOR SHALL TAKE SPECIAL PRECAUTIONS IN THE VICINITY OF
ANY OVERHEAD ELECTRIC LINES. CONTRACTOR SHALL ABIDE BY THE MOST
RECENT NATIONAL ELECTRIC CODE AND ANY REQUIREMENT BY OWNER
OF ELECTRIC LINES.
14. PROVIDE ALL SHEETING/SHORING REQUIRED TO PROTECT EXISTING
STRUCTURES, PIPES AND FACILITIES.
15. SOME DIMENSIONS AND ELEVATIONS RELATED TO EXISTING STRUCTURES
WERE OBTAINED FROM PREVIOUS CONSTRUCTION/RECORD DRAWINGS.
ALL EXISTING DIMENSIONS AND ELEVATIONS SHALL BE VERIFIED IN THE
FIELD BY THE CONTRACTOR.
16. CONTRACTOR SHALL CONTACT THE PROPER UTILITY REPRESENTATIVE FOR
QUESTIONS OR COORDINATION OF CONSTRUCTION RELATED TO EXISTING
UTILITIES.
17. CONTRACTOR SHALL COMPLETELY REMOVE AND PROPERLY DISPOSE OF
ALL STRUCTURES DESIGNATED FOR DEMOLITION AS SOON AS POSSIBLE.
18. ALL NEW UNISTRUT, ANCHORS, SUPPORT SYSTEMS AND FASTENING
HARDWARE SHALL BE 316 STAINLESS STEEL, UNLESS OTHERWISE NOTED.
19. MECHANICAL AND ELECTRICAL EQUIPMENT, SUPPORTS, ANCHORAGES,
OPENINGS, RECESSES AND REVEALS NOT SHOWN ON THE DRAWINGS BUT
REQUIRED BY THE CONTRACT DOCUMENTS SHALL BE PROVIDED.
20. EXISTING VALVES, GATES, AND CONSTRUCTION EXPANSION JOINTS MAY
LEAK TO A CERTAIN EXTENT WHEN IN A CLOSED POSITION. CONTRACTOR
SHALL PROVIDE MEANS AND EQUIPMENT NECESSARY TO CONTROL
LEAKING WATER AS NEEDED TO PERMIT CONSTRUCTION.
21. GALVANIZED STEEL PRODUCTS SHALL NOT BE USED FOR PLANT
STRUCTURE AND EQUIPMENT CONSTRUCTION.
22. EXPOSED STEEL PRODUCTS SHALL BE PROPERLY COATED IN ACCORDANCE
WITH SECTION 09 96 00.01 HIGH PERFORMANCE COATINGS.
23. ALL DEMOLISHED STRUCTURES AND NON-SALVAGED EQUIPMENT AS
WELL AS EXCESS EXCAVATED SOILS SHALL BE REMOVED AND DISPOSED OF
AS SOON AS POSSIBLE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
LAWS, REGULATIONS AND OTHER ORDINANCES AT NO ADDITIONAL COST
TO OWNER. FURNISH WRITTEN VERIFICATION FROM THE OWNER OF THE
DISPOSAL SITE AUTHORIZING THE CONTRACTOR TO DISPOSE OF
MATERIALS AT THAT LOCATION AND WRITTEN VERIFICATION FROM THE
OWNER OF THE DISPOSAL SITE AFTER PLACEMENT THAT IT IS ACCEPTABLE.
24. ALL ELEVATIONS SHALL BE VERIFIED.
25. EXCAVATION ADJACENT TO EXISTING UTILITIES TO REMAIN OR CROSSING
UTILITIES SHALL BE EXCAVATED BY HAND AND IN SUCH A MANNER AS TO
AVOID DAMAGE TO EXISTING FACILITIES.
26. ANY PLANT UTILITY AND PIPING, COMMUNICATION AND ELECTRICAL OR
INSTRUMENTATION WIRING AND CONDUIT DAMAGED DURING
CONSTRUCTION SHALL BE REPAIRED AND PLACED BACK IN SERVICE BY THE
CONTRACTOR ON THE SAME DAY THAT THE DAMAGE OCCURED. AFTER 24
HOURS OUT OF SERVICE, OWNER WILL HAVE THE OPTION OF HAVING THE
REPAIRS MADE BY A SEPARATE CONTRACTOR AND DEDUCTING THE COST
OF SAID REPAIRS FROM THE CONTRACT AMOUNT THROUGH THE PAY
ESTIMATE.
27. ALL DEMOLISHED PIPING AND APPURTENANCES, CONDUITS, ELECTRIC
WIRING AND EQUIPMENT ARE SUBJECT TO BE DISPOSED OF BY
CONTRACTOR. ALL DISPOSED EQUIPMENT AND STRUCTURES WILL BE
REMOVED FROM THE SITE BY THE CONTRACTOR.
28. CONTRACTOR SHALL REPAIR ANY EXISTING PAVEMENT DEMOLISHED FOR
UTILITY INSTALLATION OR MODIFICATION WORK. THE PAVEMENT SHALL
BE RETURNED TO EXISTING CONDITIONS.
29. EXISTING CONCRETE THRUST BLOCKING THAT CONFLICTS WITH NEW
CONSTRUCTION OR MODIFICATIONS SHALL BE REMOVED BY THE
CONTRACTOR. WHEN REMOVED, THE CONTRACTOR SHALL PROVIDE
TEMPORARY THRUST RESTRAINT TO THE EXISTING PIPING SYSTEM,
FITTINGS, AND/OR STRUCTURES. TO MAINTAIN CONTINUOUS OPERATION.
ONCE CONSTRUCTION IS COMPLETE, THE CONTRACTOR SHALL RESTORE
THE PREVIOUSLY EXISTING THRUST BLOCKING TO ITS ORIGINAL
CONDITION (UNDISTURBED EARTH). THE ORIGINAL CONDITION SHALL
INCLUDE PROPER THRUST RESTRAINT AND COMPACTED BACKFILL AS
DESCRIBED IN THE CONTRACT DOCUMENTS.
30. ANY EXISTING PIPING THAT IS AFFECTED BY NEW CONSTRUCTION OR
PIPING INSTALLATION, UNLESS DEMOLISHED AND REMOVED, SHALL BE
RETURNED TO ORIGINAL OR BETTER CONDITION AT NO ADDITIONAL COST
TO THE OWNER. PIPING REPAIR SHALL INCLUDE CONSIDERATION FOR
BACKFILL, ENCASEMENT, SUPPORTS, RESTRAINTS, FITTINGS, VALVES, HEAT
TRACINGS, INSULATION AND ANY TYPICAL OR SPECIAL COATINGS THAT
ARE APPLIED TO THE INTERIOR AND/OR EXTERIOR OF THE PIPING AND ITS
APPURTENANCES.
31. UNLOADING AND STORAGE OF EQUIPMENT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR WHO SHALL INSPECT ALL EQUIPMENT FOR
APPARENT DAMAGE. EQUIPMENT WHICH IS FOUND TO BE DAMAGED
WILL NOT BE ACCEPTED UNTIL PROPERLY REPAIRED OR REPLACED BY THE
VENDOR.
32. CONTRACTOR SHALL COORDINATE WITH THE OWNER'S PROJECT TEAM ON
CONSTRUCTION SEQUENCING AND ACTIVITIES THAT IMPACT THE CRITICAL
OPERATIONS PER SPECIFICATION 01 35 00 SPECIAL PROCEDURES PRIOR TO
THE COMMENCEMENT OF ANY WORK.
GENERAL CIVIL NOTES
1. SAFETY SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE
ENGINEER SHALL NOT BE RESPONSIBLE FOR SAFETY, MEANS, OR METHODS OF
THE CONTRACTOR.
2. THE ADDRESS OF THE PROJECT SITE IS 13700 S. DOUGLAS BLVD., OKLAHOMA
CITY, OK 73165. THE SITE IS LOCATED IN OKLAHOMA COUNTY, OKLAHOMA. THE
PARCEL OF THE PROPERTY UPON WHICH THE PROJECT SITE IS LOCATED IS
INDICATED ON FEMA FIRM PANEL 40027C0205H. THE PROJECT IS NOT LOCATED
IN A FLOOD ZONE.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO COMMENCING WORK.
4. ANY PAVEMENT DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED TO
EQUAL OR BETTER CONDITION AT THE CONTRACTOR'S EXPENSE.
5. FINAL PAVEMENT SURFACES SHALL NOT BE PLACED UNTIL ALL MAJOR
CONSTRUCTION ACTIVITIES HAVE CONCLUDED.
6. ALL SIDEWALK, ASPHALT, AND CONCRETE PAVING REMOVED AND REPLACED
SHALL BE NEAT SAW CUT.
7. CONTRACTOR SHALL PROVIDE AND MAINTAIN POSITIVE DRAINAGE DURING
ALL PHASES OF CONSTRUCTION.
O
KL
AH
O
M A
N O
DA
TE
SI
GN
ED
, S
EA
LE
D
AN
D
DA
TE
D
BY
TH
IS
D O
CU
M
EN
T
W
AS
O
RI
GI
N
AL
LY
TH
E
SE
AL
ED
, S
IG
N
ED
A
N D
DA
TE
D
DO
CU
M
EN
TS
AR
E
M
AI
N
TA
IN
ED
IN
T
HE
O
FF
IC
E O
F
FR
EE
SE
A N
D N
IC
HO
LS
A
N D
M
AY
B E
RE
VI
EW
ED
U
PO
N R
EQ
U
ES
T.
AU
TH
O
RI
ZE
D
BY
9/ 3/
M
EA
GA
N G
. B
RO
W N
P .E
SHEET INDEX
SEQ SHEET NO. TITLE
GENERAL
1 G-G-01 COVER
2 G-G-02 SHEET INDEX
3 G-G-03 GENERAL NOTES
CIVIL
4 FB-C-01 DETAILS I
5 FB-C-02 DETAILS II
6 FB-C-03 DETAILS III
HVAC
ELECTRICAL
09/05/2025
SEQ SHEET NO. TITLE
1 G-G-01 COVER
2 G-G-02 SHEET INDEX
3 G-G-03 GENERAL NOTES
4 G-H-04 HVAC NOTES, SYMBOLS & ABBREVIATIONS
5 G-E-01 ELECTRICAL GENERAL NOTES
CIVIL
6 FB-C-01 DETAILS I
7 FB-C-02 DETAILS II
8 FB-C-03 DETAILS III
HVAC
9 FB-H-01 FLOOR PLAN
10 FB-H-02 DETAILS & EQUIPMENT SCHEDULES
ELECTRICAL
11 FB-E-01 LEGEND I
12 FB-E-02 LEGEND II
13 FB-E-03 PIPE GALLERY FLOOR PLANS
14 FB-E-04 FILTER GALLERY FLOOR PLAN
15 FB-E-05 DETAILS
16 FB-E-06 SCHEDULES I
17 FB-E-07 SCHEDULE II
GENERAL
N W th
S tr e e t, S u it e
O k la h o m a C it y
O
K
P h o n e
(4
-7
W e b w w w .f re e se .c o m
C e rt if ic a te o f A u th o ri za ti o n
C
A
E xp ir a ti o n D a te
/3
/2
SEQ SHEET NO. TITLE
1 G-G-01 COVER
2 G-G-02 GENERAL NOTES AND SHEET INDEX
3 G-G-03 ELECTRICAL GENERAL NOTES
4 G-G-08 HVAC NOTES, SYMBOLS & ABBREVIATIONS
CIVIL
5 FB-C-01 DETAILS I
6 FB-C-02 DETAILS II
7 FB-C-03 DETAILS III
HVAC
8 FB-H-01 FLOOR PLAN
9 FB-H-02 DETAILS & EQUIPMENT SCHEDULES
ELECTRICAL
10 FB-E-01 LEGEND I
11 FB-E-02 LEGEND II
12 FB-E-03 PIPE GALLERY FLOOR PLANS
13 FB-E-04 FILTER GALLERY FLOOR PLAN
14 FB-E-05 DETAILS
15 FB-E-06 SCHEDULES I
16 FB-E-07 SCHEDULE II
GENERAL
UNITDESCRIPTION
ESTIMATED QUANTITIES
A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LS
ITEM
NO.
TOTAL
QUANTITY
AS-BUILT
QUANTITY
SEE SHEET G-G-02
A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02
A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02
A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02
A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02
A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02
A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02
A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02
A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02
A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02
LEAD BASED PAINT ABATEMENT
PIPE EXTERIOR COATINGS
REMOVE AND REPLACE DRAIN PIPES
REMOVE AND REPLACE DRESSER COUPLINGS
REMOVE AND REPLACE CONCRETE PIPE SUPPORTS
REMOVE AND REPLACE PIPE SUPPORT HANGERS (2 PER EA PIPE)
REPAIR OR REPLACE CONCRETE FLUME SUPPORT HANGERS
HVAC IMPROVEMENTS
DEMO EXISTING GALLERY LIGHTING9
EA
SF
LS
LS
LS
EA
EA
EA
EA
SF
INSTALL OVERHEAD LIGHTING (LOW BAY)
18,000
18,000
72 653 4 8
A
E
B
C
D
"LP-A" "DP-T""LP-B" "LP-C" "DP-A""DP-S"
XFMR-LP-C SWBD-HQ-BXFM4-LP-A SWBD-HQ-A XFMR-LP-B SWBD-HQ-A
1" = 30'-0"
1 FILTER GALLERY FLOOR PLAN
0 30' 60'
SCALE IN FEET
10' 20'
N O
R T
H
SHEET
SEQ.
F
N J
O B
N O
D A
T E
D E
S
IG
N E
D
D R
A W
N
R E
V
IS
E D
C H
E C
K E
D
F
IL
E N
A M
E V
E R
IF
Y
S C
A
LE
B a r is o n e i n ch o n o ri g in a l d ra w in g
I f n o t o n e i n ch o n th is s h e e t, a d ju st s ca le
Plot Date:
N W th
S tr e e t, S u it e
O k la h o m a C it y
O
K
P h o n e
(4
-7
W e b w w w .f re e se .c o m
C e rt if ic a te o f A u th o ri za ti o n
C
A
E xp ir a ti o n D a te
/3
/2
C
IT
Y O
F O
K
LA
H O
M A
C
IT
Y
W T
-0
-2 P
H A
S E
I I
V A
R
IO
U S
I M
P R
O V
E M
E N
T S
A T
D R
A P
E R
W T
C O
C
S E
P T
9/5/2025 5:17:36 PM
ISSUE FOR BID
F
IL
T E
R G
A
LL
E R
Y F
LO
O
R P
LA
N
FB-E-04
M C
D
M C
D
D W
K-
E L-
C O
C
-F
IL
R
E
LE
C T
R
IC
A L
GENERAL NOTES
1. REFER TO SHEETS FB-E-05 AND FB-E-06 FOR PANEL SCHEDULES.
2. THIS SHEET IS FOR REFERENCE ONLY TO SHOW PANEL LOCATIONS.
N O
IS
S U
E B
Y D
A T
E
/0
5/
CI
TY
O
F O
KL
AH
O M
A
CI
TY
W
T-
D
RA
PE
R W
AT
ER
T
RE
AT
M
EN
T
PL
AN
T
FI
LT
ER
P
IP
E
GA
LL
ER
Y
IM
PR
O
VE
M
EN
TS
N W th
S tr e e t, S u it e
O k la h o m a C it y
O
K
P h o n e
(4
-7
W e b w w w .f re e se .c o m
C e rt if ic a te o f A u th o ri za ti o n
C
A
E xp ir a ti o n D a te
/3
/2
DEMOLITION NOTES
1. THE CONTRACTOR SHALL COORDINATE THE DEMOLITION OF THE ELECTRICAL CONDUIT, WIRE, EQUIPMENT AND DEVICES WITH THE GENERAL DEMOLITION AND SCHEDULE. THE DRAWINGS ARE
INTENDED TO CONVEY THE GENERAL NATURE AND SCOPE OF THE DEMOLITION WORK. EVERY ITEM TO BE DEMOLISHED MAY NOT BE SHOWN. FIELD VERIFY WITH OWNER PRIOR TO BID, AND INCLUDE
ALL DEMOLITION WORK IN THE CONTRACT PRICE.
2. PROVIDE TEMPORARY WIRE AND CONDUIT FOR THE EQUIPMENT WHICH MAY BE AFFECTED BY THE DEMOLITION BUT TO REMAIN IN SERVICE. WHERE NECESSARY TO MAINTAIN PLANT OPERATION, THE CONTRACTOR SHALL PROVIDE A GENERATOR OR GENERATORS TO KEEP THE PROCESS IN
OPERATION WHILE SERVICE SWITCHOVER IS BEING PERFORMED.
3. RELOCATE AND RECONNECT POWER AND CONTROL RACEWAYS AND CONDUCTORS TO EQUIPMENT
AFFECTED BY DEMOLITION WORK.
4. ALL CONDUCTORS BEING DEMOLISHED SHALL BE DISCONNECTED AND REMOVED FROM THE LOAD
TO THE SOURCE. SURFACE MOUNTED CONDUITS AND MOUNTING HARDWARE SHALL BE REMOVED.
UNDERGROUND CONDUITS WHICH ARE NOT BEING REMOVED OR NOT BEING REUSED SHALL BE
CAPPED AND TAGGED AS SPARE, WITH INFORMATION CLEARLY INDICATING THE LOCATION OF THE
OTHER END, UNLESS NOTED OTHERWISE.
5. ALL SURFACES WHERE DEMOLISHED EQUIPMENT OR CONDUIT IS REMOVED SHALL BE CLEANED, PATCHED AND PAINTED TO MATCH THE SURROUNDING SURFACE.
6. THE CONTRACTOR SHALL BE RESPONSIBLE TO CHECK THE FUNCTION AND ROUTE OF EACH
CONDUCTOR BEFORE REMOVING OR DISCONNECTING.
7. THE CONTRACTOR SHALL FIELD VERIFY PRIOR TO BID TO DETERMINE IF CONDUCTORS WHICH ARE
TO STAY IN SERVICE (NOT BEING DEMOLISHED) ARE INSTALLED IN A COMMON CONDUIT WITH
CONDUCTORS WHICH ARE BEING DEMOLISHED, THE CONTRACTOR SHALL REMOVE ALL
CONDUCTORS FROM THE CONDUIT, PROVIDE NEW CONDUCTORS WHICH ARE REPLACEMENTS FOR
THE CONDUCTORS THAT ARE TO REMAIN IN SERVICE AND RE-INSTALL THE NEW CONDUCTORS.
AFTER THE CONDUCTORS ARE PULLED, MEGGER OR HIPOT TEST EACH CONDUCTOR. CONNECT BOTH ENDS OF THE NEW CONDUCTORS AND TEST THE SYSTEM FOR PROPER FUNCTION. DO NOT RE-PULL
USED CONDUCTORS.
8. WHERE EQUIPMENT IS BEING RE-FED FROM A NEW SOURCE, EXISTING CONDUIT MAY BE REUSED
ONLY IF THE CONDUIT AND FITTINGS ARE OF THE TYPE SPECIFIED FOR NEW WORK ON THIS
CONTRACT.
9. IF NOT, THE CONDUIT AND CONDUCTORS SHALL BE REPLACED WITH NEW MATERIAL MEETING THE
SPECIFICATIONS, AT NO ADDITIONAL COST TO THE OWNER.
10. THE OWNER HAS THE RIGHT OF FIRST REFUSAL TO THE EQUIPMENT BEING REMOVED. THE
CONTRACTOR SHALL DELIVER THE EQUIPMENT WHICH THE OWNER WISHES TO KEEP TO A LOCATION DESIGNATED BY THE OWNER. SEE SECTION 26 05 33. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS AND PERMITS REQUIRED TO DISPOSE OFF SITE ALL DEMOLISHED EQUIPMENT REFUSED BY
OWNER.
11. THE CONTRACTOR SHALL NOT MAKE ANY MODIFICATIONS UNTIL THE FOLLOWING HAS BEEN DONE:
A. THE OWNER/CONTRACTOR SHALL WITNESS AND RECORD THE CONDITION OF THE EXISTING
EQUIPMENT, THE CONTRACTOR SHALL NOTE DOWN ANY DEFECTS OR DEFICIENCIES.
B. THE OWNER SHALL OPERATE THE EQUIPMENT TO DEMONSTRATE THE CURRENT CONDITIONS.
THE CONTRACTOR SHALL NOTE DOWN ANY DEFECTS OR DEFICIENCIES.
C. A WRITTEN AND PHOTOGRAPHIC RECORD OF THE OPERATION AND EXISTING CONDITION SHALL BE KEPT IN A THREE RING BINDER AT THE OWNER/CONTRACTOR TRAILER, IN FORM OF PICTURES
AND INFORMATION ON A FORM.
D. A FORM SHALL BE GENERATED BY THE CONTRACTOR TO RECORD THE OBSERVATIONS. BOTH
PARTIES SHALL SIGN ON THE FORM.
E. AFTER THE CHANGES ARE MADE, THE EQUIPMENT SHALL BE INSPECTED AND RE-TESTED TO
DEMONSTRATE THAT IT FUNCTIONS CORRECTLY.
F. NO PORTION OF EXISTING CONDUCTORS SHALL BE SPLICED TO NEW CONDUCTORS FOR RE-USE
WITHOUT SPECIFIC APPROVAL FROM THE OWNER/ENGINEER ON A CASE-BY-CASE BASIS.
12. THE CONTRACTOR SHALL BE RESPONSIBLE TO FURNISH AND INSTALL MATERIAL OR EQUIPMENT
DAMAGED DURING THE COURSE OF HIS WORK.
15. ALL SLOTTED CHANNEL, SLOTTED CHANNEL SUPPORT MATERIAL, WASHERS, SCREWS, NUTS, CONDUIT CLAMPS, ALL THREAD SPRING NUTS AND MISC. MOUNTING HARDWARE SHALL BE 316
STAINLESS STEEL.
16. ALL CONDUITS AND WIRES SHOWN ON THE INTERFACE DIAGRAM SHALL BE INSTALLED BY THE
CONTRACTOR. GROUPING OF CONDUIT AND WIRE MAY BE CHANGED, IF APPROVED BY THE
ENGINEER AND OWNER.
17. ALL CONDULETS SHALL BE ALUMINUM FORM 7 AND SHALL HAVE 316 SS CLAMP COVERS WITH 316
SS CLAMPS AND SCREWS. SCREW DOWN COVERS ARE UNACCEPTABLE.
18. ALL BARE COPPER GROUNDING CONDUCTORS SHALL BE TINNED, ALL GROUND RODS SHALL BE COPPER CLAD STEEL, 3/4" BY 10' LONG. ALL EXPOSED COPPER GROUND CABLES SHALL BE GREEN
INSULATED CONDUCTORS. PROVIDE XHHW-2 INSULATION.
19. WHERE NOTES ON THE DRAWING INDICATE THAT THE CONTRACTOR SHALL FIELD VERIFY, THE INTENT IS FOR THE CONTRACTOR TO INVESTIGATE TO THE EXTENT NECESSARY TO PROVIDE THE
WORK AND MATERIALS PRIOR TO BIDDING AND INCLUDE ALL COSTS IN THE BID PRICE. THE
CONTRACT PRICE SHALL NOT BE INCREASED WHEN THE CONTRACTOR HAS NOT INVESTIGATED PER
THE NOTES DIRECTING THAT TO BE DONE.
20. CONDUITS SHALL NOT BE INSTALLED INTO THE TOP OF ANY NEMA ENCLOSURES RATED FOR DAMP, WET OR HOSE DOWN AREAS MOUNTED IN INDOOR PROCESS AREAS, OUTDOOR AREAS, OR ANY
AREA NOT RATED TO BE DRY (ELECTRICAL ROOMS, CONTROL ROOMS, OR OFFICE AREAS). ANY
ENCLOSURES THAT HAVE BEEN INSTALLED WITH TOP CONDUIT ENTRIES SHALL BE REMOVED AND
REPLACED AT THE CONTRACTOR'S EXPENSE.
21. ALL PORTIONS OF CONDUITS INDICATED FOR REUSE SHALL BE CLEANED BY THE CONTRACTOR
BEFORE REUSE. CLEANING PROCEDURES ARE AS FOLLOWS:
A. PULL A WIRE BRUSH OF THE APPROPRIATE SIZE THROUGH THE CONDUIT.
B. PULL A CONDUIT SWAB OF THE APPROPRIATE SIZE THROUGH THE CONDUIT.
C. PULL A MANDREL OF THE APPROPRIATE SIZE THROUGH THE CONDUIT.
D. THIS PROCEDURE MAY HAVE TO BE REPEATED SEVERAL TIMES UNTIL THE CONDUIT IS CLEAN.
E. LEAVE A PULL STRING IN THE EMPTY CONDUIT AND PLUG BOTH ENDS OF THE CONDUIT AFTER
CLEANING. PLUGS ARE TO BE REMOVED ONLY TO INSTALL NEW CONDUCTORS. THE
CONTRACTOR IS RESPONSIBLE TO REPLACE ANY CONDUIT DAMAGED DURING THESE CLEANING
PROCEDURES AT NO ADDITIONAL COST TO OWNER.
22. THE CONTRACTOR SHALL INSTALL ON ALL CONDUITS PROVIDED OR MODIFIED UNDER THE SCOPE OF THIS PROJECT WITH CONDUIT IDENTIFICATION PLATES. MODIFICATIONS TO CONDUITS INCLUDE CHANGES IN CONDUIT ROUTING AND/OR REPLACING EXISTING OR INSTALLING NEW CONDUCTORS.
THE CONTRACTOR SHALL COORDINATE WITH THE OWNER THE NAMING SYSTEM TO USE IN
IDENTIFYING CONDUITS. WHEN MORE THAN TWO CONDUITS ENTER A JUNCTION BOX, PULL BOX, TERMINAL ENCLOSURE, ETC., ALL CONDUITS SHALL CONTAIN AN IDENTIFICATION PLATE WITH A
UNIQUE IDENTIFICATION.
23. THE CONTRACTOR SHALL PROVIDE NAMEPLATES ON ALL EQUIPMENT WITH DESIGNATIONS AS
REQUIRED BELOW, UNLESS NOTED OTHERWISE BY OWNER.
A. NAMEPLATES SHALL BE ENGRAVED, LAMINATED PLASTIC, NOT LESS THAN 1/16-IN THICK BY 3/4-IN HIGH BY 2 1/2-IN WIDE (MINIMUM) WITH 3/16-IN HIGH BLACK LETTERS ON A WHITE
BACKGROUND.
B. NAMEPLATES SHALL BE 316 SS SCREW MOUNTED TO ALL ENCLOSURES. SCREWS ON NEMA 4
ENCLOSURES SHALL BE SEALED BY UL LISTED METHOD. CONTRACTOR SHALL PROVIDE
SUBMITTAL FOR METHOD OF SEALING SCREWS FOR APPROVAL. EPOXY ADHESIVE OR FOAM
TAPE IS NOT ACCEPTABLE.
THE CONTRACTOR SHALL SUBMIT AS-BUILT DRAWINGS INDICATING ALL EQUIPMENT IDENTIFIED
ABOVE WITH THEIR APPROPRIATE NAMEPLATE DESIGNATION.
24. REFER TO THE CONDUIT TABLE BELOW FOR APPLICABLE TYPE OF CONDUIT PER LOCATION.
25. THE CONTRACTOR SHALL REFER AND PROVIDE EQUIPMENTS AND ACCESSORIES AS PER THE LATEST
WQ STANDARD EQUIPMENT LIST AND WQ ENGINEERING GUIDELINES.
CONDUIT TYPE LOCATION
2. LIQUID TIGHT FLEXIBLE ALUMINUM
CONDUIT
RACEWAY CONNECTION TO VIBRATING EQUIPMENT ONLY, IN ALL
AREAS.
3. GALVANIZED RIGID CONDUIT ALL ABOVE GRADE NON-PROCESS AREAS, EXCEPT FOR CONCRETE
EMBEDDED AND OTHER LOCATIONS DESCRIBED IN THIS TABLE.
1. PVC SCHEDULE 40 CONDUIT UNDERGROUND ENCASED IN RED DYE REINFORCED CONCRETE.
ALL ABOVE GRADE PROCESS AREAS AND ALL EXTERIOR APPLICATION, ALL
ELBOWS UNDERGROUND ENCASED IN RED DYE REINFORCED CONCRETE, ALL
STUB UPS AND USED AS SHOWN ON VARIOUS ELECTRICAL STANDARD
DETAILS.
4. PVC COATED GALVANIZED RIGID CONDUIT
1. ALL EQUIPMENT WIRING, RACEWAYS, ETC. SHALL BE INSTALLED AND GROUNDED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, LOCAL CODES, AND INDUSTRY STANDARDS (UL, NEMA, IEEE, ANSI, ETC.) THE DRAWING NOTES AND DETAILS SHALL BE COMPLIED
WITH IN ADDITION TO THE REQUIREMENTS IN THE SPECIFICATIONS. REFER TO EACH
SPECIFICATION SECTION FOR SPECIFIC REQUIREMENTS.
2. ALL RACEWAY INSTALLATIONS SHALL BE INSTALLED IN A MANNER TO PREVENT CONFLICTS WITH
EQUIPMENT AND STRUCTURAL CONDITIONS. ALL EXPOSED RACEWAY SHALL BE INSTALLED
PARALLEL TO BEAMS, CEILINGS, FLOORS AND WALLS. SEE SECTION 26 05 33 FOR ADDITIONAL
REQUIREMENTS.
3. CONDUITS SHALL BE TERMINATED IN A NEAT MANNER AND STRICTLY IN ACCORDANCE WITH THE SPECIFICATIONS AND DRAWING DETAILS. SEE SECTION 26 05 33 FOR ADDITIONAL REQUIREMENTS.
4. CONDUITS TERMINATED INTO ENCLOSURES SHALL BE PERPENDICULAR TO THE WALLS OF THE ENCLOSURE. THE USE OF SHORT SEAL-TIGHT ELBOW FITTINGS FOR SUCH TERMINATIONS WILL NOT
BE PERMITTED.
5. ALL RACEWAY INSTALLATIONS, CROSSING EXPANSION JOINTS OR TRANSITIONS FROM BELOW
GRADE TO EXPOSED ABOVE GRADE, SHALL HAVE EXPANSION OR EXPANSION/DEFLECTION TYPE
FITTINGS AS SPECIFIED FOR THE APPLICATION. SEE THE DRAWINGS AND SECTION 26 05 33 FOR THE
EXACT TYPE OF FITTING TO BE USED.
6. NO EXPOSED CONDUIT SMALLER THAN 3/4", NOR WIRE SMALLER THAN NO. 12 AWG, SHALL BE
USED UNLESS SPECIFICALLY NOTED.
7. ALL UNDERGROUND SINGLE CONDUIT RUNS, AND DUCTBANKS OF MULTIPLE CONDUIT RUNS,
SHALL BE PVC SCHEDULE 40 CONDUIT, ENCASED IN REINFORCED RED CONCRETE, AND THE
CONCRETE DYED RED BEFORE PLACEMENT, AS SPECIFIED IN SECTION 26 05 33. MINIMUM SIZE
SHALL BE 2 INCH. THE CONTRACTOR SHALL FIELD VERIFY THE ROUTING OF ALL EXISTING
UNDERGROUND CONDUIT AND DUCTBANKS AND SHALL COORDINATE THE ROUTING OF NEW
CONDUIT AND DUCTBANKS TO AVOID INTERFERENCE WITH EXISTING CONDUIT AND DUCTBANKS
AND OTHER UNDERGROUND UTILITIES.
8. FOR ALL JUNCTION BOXES, PULL BOXES AND TERMINATION BOXES IN THE RACEWAY SYSTEM IN NEMA 12 AREAS, BOXES SHALL BE OF ALUMINUM. FOR NEMA 4X AREAS BOXES SHALL BE OF 316 STAINLESS STEEL, UNLESS NOTED OTHERWISE, SEE SECTION 26 05 33 FOR BOX DETAILS AND
SPECIFICATIONS.
9. WHERE RACEWAYS ENTER JUNCTION BOXES OR CONTROL PANELS CONTAINING ELECTRICAL OR INSTRUMENTATION EQUIPMENT, ALL ENTRANCES SHALL BE SEALED WITH WATERTIGHT SEALANT.
REFER TO SECTION 26 05 33 FOR DETAILS.
10. ALL EQUIPMENT AND ELECTRICAL EQUIPMENT ENCLOSURE LOCATIONS, OR TERMINAL BOX
LOCATIONS, ARE APPROXIMATE. THE EXACT LOCATIONS SHALL BE COORDINATED WITH AND
APPROVED BY THE OWNER/ENGINEER, DURING CONSTRUCTION, AT NO ADDITIONAL COST TO THE
OWNER.
11. ALL EQUIPMENT AND ELECTRICAL EQUIPMENT ENCLOSURES DIMENSIONS ARE APPROXIMATE. ALL EQUIPMENT AND ELECTRICAL EQUIPMENT ENCLOSURES OR TERMINAL BOX DIMENSIONS SHALL BE VERIFIED WITH THE EQUIPMENT SUPPLIER. ALLOW FOR LOCATION CHANGES AND INCLUDE IN THE CONTRACT PRICE. THE EXACT LOCATIONS OF ALL ELECTRICAL EQUIPMENT AND ROUTING OF ALL
CABLES AND CONDUITS SHALL BE COORDINATED WITH AND APPROVED BY THE OWNER/ENGINEER
DURING CONSTRUCTION.
12. CORING OF AN EXISTING STRUCTURE SHALL BE COORDINATED WITH AND APPROVED BY THE
OWNER/ENGINEER. CORING THROUGH STRUCTURAL BEAMS IS STRICTLY PROHIBITED, WITHOUT
PRIOR WRITTEN APPROVAL FROM THE OWNER/ENGINEER.
13. PROVIDE CONDUIT SEALS FOR CONDUIT PENETRATIONS. SEE SECTION 26 05 33 FOR DETAILS.
14. THIS IS AN OPERATING FACILITY. THE CONTRACTOR SHALL COORDINATE ALL WORK WITH THE
OWNER. NO SHUTDOWN OF ELECTRICAL OR CONTROL EQUIPMENT WILL NOT BE PERMITTED
WITHOUT A SHUTDOWN REQUEST IN WRITING BEING SUBMITTED AND APPROVED PER
SPECIFICATIONS.
ELECTRICAL GENERAL NOTES
GE
N
ER
AL
N O
TE
S
G-G-03
25. NEW LIGHT FIXTURES SHALL BE IN ACCORDANCE WITH OCWUT "WQ STANDARD EQUIPMENT
LIST, VERSION 6, FOR LED LOW BAY LIGHT: SIGNIFY GARDCO SOFTVIEW LED
(SVPG-A10-750-5RD-SUR-UNV-MG).
ABBREVIATIONS
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)HVAC SYMBOLS
A/C AIR CONDITIONING
AFF ABOVE FINISHED FLOOR
AI ANALOG INPUT
AO ANALOG OUTPUT
APPROX APPROXIMATELY
ARCH ARCHITECTURE/ARCHITECTURAL
AV ANALOG VALUE
BI BINARY INPUT
BHP BRAKE HORSEPOWER
BO BINARY OUTPUT
BOD BOTTOM OF DUCT
BTUH BRITISH THERMAL UNIT PER HOUR
BV BINARY VALUE
C CELSIUS
CC COOLING COIL
CFM CUBIC FEET PER MINUTE
CD CONDENSATE DRAIN
CONN CONNECTION
dB DECIBELS
DI DIGITAL INPUT
DIA DIAMETER
DB DRY BULB
DDC DIRECT DIGITAL CONTROL
DEG DEGREE
DO DIGITAL OUTPUT
DX DIRECT EXPANSION
DWGS DRAWINGS
ELEC ELECTRIC/ELECTRICAL
EAT ENTERING AIR TEMPERATURE
EWT ENTERING WATER TEMPERATURE
EFF EFFICIENCY
EL ELEVATION
EMCS ENERGY MONITORING AND CONTROL SYSTEM
EXH EXHAUST
F FAHRENHEIT
FLEX FLEXIBLE
FPM FEET PER MINUTE
FT FEET, FOOT
GPM GALLONS PER MINUTE
HC HEATING COIL
HVAC HEATING, VENTILATION AND AIR CONDITIONING
HZ HERTZ
HP HORSEPOWER
HTG HEATING
IN INCHES
KW KILOWATT
LAT LEAVING AIR TEMPERATURE
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MECH MECHANICAL
MCA MINIMUM CIRCUIT AMPACITY
MBH THOUSANDS BTU's PER HOUR
MIN MINIMUM
MOCP MAXIMUM OVERCURRENT PROTECTION
NFPA NATIONAL FIRE PROTECTION ASSOC.
NC NOISE CRITERIA
NOM NOMINAL
NTS NOT TO SCALE
NO NUMBER
N.C. NORMALLY CLOSED
N.O. NORMALLY OPEN
OA OUTSIDE AIR
P/PH PHASE
PLBG PLUMBING
PSI POUNDS PER SQUARE INCH
RE REFER/REFERENCE
RA RETURN AIR
RPM REVOLUTIONS PER MINUTE
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOC.
SQ FT SQUARE FEET
SP STATIC PRESSURE
SA SUPPLY AIR
TEMP TEMPERATURE
T-STAT THERMOSTAT
TYP TYPICAL
VAV VARIABLE AIR VOLUME
VFD VARIABLE FREQUENCY DRIVE
VD VOLUME DAMPER
WT WATTS
WTR WATER
WC WATER COLUMN
WG WATER GAUGE
WB WET BULB
DUCTWORK SYMBOLS
DUCTWORK SIZE TRANSITION.
RADIUS DUCTWORK ELBOW
ROUND OR RECTANGULAR
RADIUS DUCTWORK ELBOW
ROUND OR RECTANGULAR
FLEXIBLE DUCT
ROUND DUCTWORK
RETURN/TRANSFER AIR GRILLE
EXHAUST GRILLE
SUPPLY AIR PLENUM SLOT DIFFUSER
SD - SMOKE DAMPER
CD - COMBINATION FIRE/SMOKE DAMPER
RELIEF OR EXHAUST AIR DUCT DOWN
MANUAL VOLUME (BALANCE) DAMPER
90° ELBOW WITH TURNING VANES
RELIEF OR EXHAUST AIR DUCT UP
RETURN AIR DUCT DOWN
FD - FIRE DAMPER
MOTORIZED DAMPER
SUPPLY AIR DUCT UP
SUPPLY AIR DUCT DOWN
FLEXIBLE DUCT CONNECTION
RETURN AIR DUCT UP
TO EQUIPMENT
12/12
12"
FD
M
ROUND DUCT BRANCH TAKE-OFF FROM
RECTANGULAR OR FLAT OVAL MAIN WITH
CONICAL TAP. PROVIDE BALANCE DAMPER
FOR LOW PRESSURE DUCTWORK ONLY
RECTANGULAR DUCTWORK BRANCH TAKE-OFF
W/DAMPER AND 45 DEGREE BRANCH INLET
RECTANGULAR DUCTWORK. SIZE INDICATED IN
INCHES, FIRST NUMBER IS SIDE SHOWN
SUPPLY AIR DIFFUSER - ARROWS INDICATE
PATTERN. NO ARROWS SHOWN EQUALS
4-WAY.
SA
SA
RA
RA
EA
EA
EQUIPMENT DESIGNATIONS
DOAS DEDICATED OUTSIDE AIR UNIT
EF EXHAUST FAN
L LOUVER
SF SUPPLY FAN
GUH GAS-FIRED UNIT HEATER
DE = CIRCULAR EQUIVALENT OF RECTANGULAR DUCT
GENERAL NOTES
IN INCHES
B = LENGTH OF OTHER SIDE OF DUCT IN INCHES
1. THIS PROJECT IS DESIGNED BASED ON THE FOLLOWING CODES:
INTERNATIONAL MECHANICAL CODE 2015, INTERNATIONAL ENERGY
CONSERVATION CODE 2009, ASHRAE 62.1.
2. ALL INFORMATION REQUIRED FOR DESIGN MAY NOT BE COVERED IN
THE DRAWINGS. REFER TO DIVISION 23 TECHNICAL SPECIFICATIONS
AND OTHER RELATED SECTIONS FOR ADDITIONAL INFORMATION.
3. ALL DUCT SIZES SHOWN ON THE DRAWINGS ARE NET INSIDE CLEAR
DIMENSIONS.
4. UTILIZE LONG RADIUS ELBOWS WHERE SPACE PERMITS UNLESS
OTHERWISE NOTED. ALL RECTANGULAR ELBOWS SHALL CONTAIN
TURNING VANES.
5. COORDINATE WITH OTHER UTILITIES TO AVOID INTERFERENCES WHEN
INSTALLING DUCTWORK, PIPING AND EQUIPMENT.
6. FURNISH AND INSTALL ALL EQUIPMENT AS PER MANUFACTURER'S
RECOMMENDATIONS AND INSTRUCTIONS. PROVIDE MODIFICATIONS
AND ACCESSORIES AS REQUIRED AND RECOMMENDED BY THE
MANUFACTURER TO ASSURE PROPER OPERATION OF THE
EQUIPMENT.
7. VERIFY DIMENSIONS, LOCATIONS, ELEVATIONS AND CONFIGURATION
OF ALL ITEMS ASSOCIATED WITH THE INSTALLATION OF DUCTWORK
AND EQUIPMENT.
8. EQUIPMENT, DUCTWORK AND PIPING SHALL NOT BE SUPPORTED OR
SECURED TO OTHER EQUIPMENT, DUCTWORK, PIPING OR OTHER
UTILITIES.
9. PAINT ALL EQUIPMENT VISIBLE THRU AIR DEVICES MATTE BLACK.
10. PROVIDE MANUAL VOLUME DAMPERS IN ALL DUCTWORK AT ALL
DUCT SPLITS, BRANCH RUNOUTS AND DUCT COLLARS FOR REGISTERS.
ALL MANUAL DAMPERS MAY NOT BE SHOWN ON DRAWINGS.
11. ALL DUCTWORK SHALL BE CONSTRUCTED, SEALED AND INSTALLED IN
CONFORMANCE TO SMACNA DUCT CONSTRUCTION STANDARDS.
12. TO RESOLVE FIELD PROBLEMS IN ROUTING DUCTWORK THE
CONTRACTOR SHALL USE THE SAME CIRCULAR EQUIVALENT
DIAMETER TO TRANSFORM DUCT SIZE FROM THAT SPECIFIED ON THE
DRAWINGS.
13. PROVIDE FIRE DAMPERS IN DUCTWORK AT ALL FIRE BARRIER
PENETRATIONS. PROVIDE ACCESS DOORS IN DUCTWORK TO VIEW
AND SERVICE FIRE DAMPERS PER SMACNA AND APPLICABLE LOCAL
CODES.
14. PROVIDE FIRE RESISTANT FLEXIBLE CONNECTION WHENEVER
DUCTWORK IS CONNECTED TO MOTORIZED EQUIPMENT.
15. DUCT MATERIAL SHALL BE ALUMINUM WITH THICKNESS AS PER
SMACNA CONSTRUCTION STANDARDS.
16. PROVIDE OSHA-REQUIRED CLEARANCES AROUND ALL HVAC
EQUIPMENT AND COMPONENTS FOR PERSONNEL ACCESS AND
MAINTENANCE.
17. ALL PIPE HANGERS AND SUPPORTS SHALL COMPLY WITH
MANUFACTURER'S STANDARDIZATION SOCIETY (MSS) STANDARDS.
VERTICAL PIPES MUST BE SUPPORTED AT EACH FLOOR WITH PIPE
CLAMPS.
18. INSULATE BACKS AND PLENUMS OF SUPPLY AIR DEVICES WITH
MINIMUM 1" MINERAL FIBER.
19. ALL AIR MOVING EQUIPMENT CONTAINING PARTICULATE FILTERS
SHALL NOT BE OPERATED WITHOUT PARTICULATE FILTERS IN PLACE.
20. ADD DIELECTRIC CONNECTIONS BETWEEN PIPES OF DIFFERENT
METALS.
21. MAINTAIN A VERTICAL SLOPE OF 1/8" PER FOOT IN THE DIRECTION OF
FLOW FOR ALL HORIZONTAL CONDENSATE PIPING. ROUTE
CONDENSATE DRAIN ALONG WALL TO TERMINATE OPEN-SITE AT MOP
SINK.
22. INSTALL ALL PIPING PARALLEL TO BUILDING LINES UNLESS STATED
OTHERWISE IN DRAWINGS.
A = LENGTH OF ONE SIDE OF DUCT IN INCHES
DE =
1.30 (AB)
(A + B)
0.625
0.250
"X" INDICATES ZONE)
(LOCAL CONTROL
SP
DIFFUSER/GRILLE/REGISTER LABEL:
"A" - TYPE/DESIGNATION
"200" - AIRFLOW (CFM)
THERMOSTAT
H
T
TT
DRAWING NOTE REFERENCE
DIAMETER/PHASE
DUCT SMOKE DETECTOR
P
S
C
MISCELLANEOUS
X
A200
DUCT MOUNTED STATIC
PRESSURE SENSOR
HUMIDITY SENSOR
TEMPERATURE SENSOR
CO2 SENSOR
PRESSURE SENSOR
SENSOR WITH LOCKING
PROTECTIVE GUARD
POINT OF NEW
CONNECTION BETWEEN
NEW AND EXISTING WORK
DOUBLE LINE
EXISTING EQUIPMENT (FANS,
AIR DEVICES, PUMPS, ETC.)
TO BE RELOCATED.
D U
C T
W O
R K
P
IP
IN
G
NEW
DEMOLITION
EXISTING
TO REMAIN
NEW PLANS
PLAN SYMBOLOGY
R
NEW
DEMOLITION
NEW EQUIPMENT
EXISTING
TO REMAIN
SHEET
SEQ.
F
N J
O B
N O
D A
T E
D E
S
IG
N E
D
D R
A W
N
R E
V
IS
E D
C H
E C
K E
D
F
IL
E N
A M
E V
E R
IF
Y
S C
A
LE
B a r is o n e i n ch o n o ri g in a l d ra w in g
I f n o t o n e i n ch s h e e t, a d ju st s ca le
Plot Date:
N W th
S tr e e t, S u it e
O k la h o m a C it y
O
K
P h o n e
(4
-7
W e b w w w .f re e se .c o m
C e rt if ic a te o f A u th o ri za ti o n
C
A
E xp ir a ti o n D a te
/3
/2
C
IT
Y O
F O
K
LA
H O
M A
C
IT
Y
W T
-0
D R
A P
E R
W A
T E
R T
R E
A T
M E
N T
P
LA
N T
F
IL
T E
R P
IP
E
G A
LL
E
R Y
I M
P R
O V
E M
E N
T S
C O
C
S E
P
9/4/2025 3:50:54 PM
ISSUE FOR BID
H V
A C
N O
T E
S
S Y
M B
O
LS
A
B B
R E
V
IA
T
IO
N S
G-G-08
D C
A
D C
A
W A
Y
H V
A C
-C O
C
-F
IL
R
.R V
T
H V
A C
N O
IS
S U
E B
Y D
A T
E
/0
4/
FILTER BUILDING PIPE GALLERY
PIPE COATINGS (TYP)
NOT TO SCALE
FILTER 1 FILTER 2 FILTER 3 FILTER 4 FILTER 5 FILTER 6
DI AND CI WATER PIPING TO BE
COATED WITH SYSTEM NO. 8 PER
SECTION 09 96 00.0
AIR SUPPLY PIPING TO BE
COATED WITH SYSTEM NO. 8 PER
SECTION 09 96 00.0.
FILTER BUILDING CIVIL NOTES:
1. CONTRACTOR TO COORDINATE WITH OWNER'S PROJECT TEAM TO SCHEDULE ALL
OUTAGES OR IMPACTS TO FILTER OPERATIONS REQUIRED TO COMPLETE COATING
AND CONSTRUCTION ACTIVITIES IN ACCORDANCE WITH SPECIFICATION 01 35 00.
2. NEW D.I. PIPE AND FITTINGS SHALL BE COATED IN ACCORDANCE WITH SPECIFICATION
09 96 00.01.
3. CONTRACTOR SHALL REMOVE AND REPLACE ALL EXISTING COATINGS FROM THE DI
AND CI WATER AND AIR PIPING WITHIN THE PIPE GALLERY, SEE DETAIL THIS PAGE.
4. EXISTING COATINGS CONTAIN LEAD-BASED PAINTS. REMOVE ALL COATINGS FROM
EXISTING D.I. AND C.I. PIPES LOCATED IN THE PIPE GALLERY, SHOWN IN DETAIL 2, IN
ACCORDANCE WITH SECTION 02 83 01. NEW COATINGS SHALL BE INSTALLED IN
ACCORDANCE WITH SPECIFICATION 09 96 00.01.
5. CONTRACTOR TO PROTECT EXISTING VALVES, VALVE ACTUATORS, SAMPLE PORTS,
MISC. SMALL DIAMETER PIPING, ELECTRICAL CONDUIT, ANALYZERS, AIR SCRUBBER
EQUIPMENT, EFFLUENT SEAL BOXES, AND ALL OTHER SURFACES NOT INTENDED TO BE
COATED DURING CONSTRUCTION.
6. BACKGROUND IMAGES ARE SHOWN FROM RECENT PROJECT RECORD DRAWINGS AND
ARE FOR GRAPHICAL REPRESENTATION ONLY. CONTRACTOR TO VERIFY EXACT
LOCATION AND ORIENTATION OF PROPOSED WORK PRIOR TO ORDERING OF
MATERIALS AND INSTALLATION.
7. CONCRETE PIPE SUPPORTS ON FILTERS #5 AND #6 HAVE BEEN DAMAGED AND MUST
BE REPLACED.
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
RE
VI
SE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 9/3/2025 4:48 PM Plot By: 03761 Filename: N:\WTU\Drawings\WT0295\CV-ALL-DETL-PIPE-IMP.dwg
CV
-A
LL
-D
ET
L-
PI
PE
-IM
P.
dw g
La st
S av ed : 9
/3 /2
4:
d
By : 0
Fi le na m e:
N
W
TU
\D ra w in gs
\W T0
5\
CV
-A
LL
-D
ET
L-
PI
PE
-IM
P.
dw g
AC
AD
R el
: 2 4.
2s (L
M S
Te ch
ISSUE FOR BID
CI
TY
O F
O
KL
AH
O
M A
CI
TY
W T-
D
RA
PE
R
W
AT
ER
T
RE
AT
M
EN
T
PL
AN
T
FI
LT
ER
P
IP
E
GA
LL
ER
Y
IM
PR
O
VE
M
EN
TS
CO
C2
SE
P
N W th S t., S ui te
O kl ah om a Ci ty , O
K
Ph on e
5)
-7
W eb w w w .fr ee se
.c om
Ce rt ifi ca te o f A ut ho riz at io n:
C
A#
Ex pi ra tio n
Da te
: 0 6/
/2
TREATMENT TRAIN 1 TREATMENT TRAIN 2 TREATMENT TRAIN 3
FILTERS 1-6 FILTERS 7-12 FILTERS 13-18
LOCATION OF CONCRETE FLUME
RE: FB-C-03
SITE PLAN OF PRIMARY PLANT AREA
NOT TO SCALE
NORTH
FILTER BUILDING REPAIR AND REPLACEMENT SCHEDULE
FILTER #
PIPE
REPLACEMENT/SIZE
DRESSER COUPLING
REPLACEMENT
PIPE HANGER
REPAIR/REPLACEMENT
1 Y/16" Y N 2 N Y N 3 Y/16" Y N 4 Y/16" Y N 5 Y/16" Y N 6 N Y N 7 Y/16" Y Y 8 N Y Y 9 N Y Y
10 N Y Y 11 N Y Y 12 N Y N 13 N Y N 14 N Y Y 15 N Y Y 16 N Y Y 17 N Y Y 18 N Y N
CONCRETE
FLUME N N Y
O
KL
AH
O
M A
N O
DA
TE
SI
GN
ED
, S
EA
LE
D
AN
D
DA
TE
D
BY
TH
IS
D O
CU
M
EN
T
W
AS
O
RI
GI
N
AL
LY
TH
E
SE
AL
ED
, S
IG
N
ED
A
N D
DA
TE
D
DO
CU
M
EN
TS
AR
E
M
AI
N
TA
IN
ED
IN
T
HE
O
FF
IC
E O
F
FR
EE
SE
A N
D N
IC
HO
LS
A
N D
M
AY
B E
RE
VI
EW
ED
U
PO
N R
EQ
U
ES
T.
AU
TH
O
RI
ZE
D
BY
9/ 3/
M
EA
GA
N G
. B
RO
W N
P .E
CI
VI
L
FI
LT
ER
B
U
IL
DI
N
G
PI
PE
G
AL
LE
RY
DE
TA
IL
S I
FB-C-01
SD
M M
M M
GB
Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
/REPLACEMENT
09/05/2025
N W th
S tr e e t, S u it e
O k la h o m a C it y
O
K
P h o n e
(4
-7
W e b w w w .f re e se .c o m
C e rt if ic a te o f A u th o ri za ti o n
C
A
E xp ir a ti o n D a te
/3
/2
CONCRETE PIPE SUPPORT
CRADLE DETAIL
NOT TO SCALE
2" C/
C
#4 T
IE
S
3"CLR
(TYP VA
RI
ES
#4 @ 12"C/C MAX
PIPE OD + =1'-2"
EXIST SLAB
3"
#4 BARS, EF
8"
3"
CL
R (T
YP
ADD'L #4 DIAGONAL BARS, EF
8"
3"
8"
#4 TIES @ 12"C/C (MAX)
3" C
LR
#4 DOWELS INTO EXISTING SLAB @ 12" C/C
SPACING, EF, MIN EMBD DEPTH OF 5"
(TYP), HILTI HIT-RE 500 V3 +REBAR OR
APPROVED EQUAL
3" C
LR
EXIST SLAB
SEE NOTE 1SEE NOTE 1
DRAIN PIPE REPLACEMENT
NOT TO SCALE
24" BACKWASH WATER LINE
24"X24" TEE
TO REMAIN, TYP.
24"X20" 90° BEND
TO REMAIN, TYP.
18"X16" DRAIN TEE
TO REMAIN, TYP.
REPLACE 16" C.I.
DRAIN PIPE, TYP.
(SEE NOTE 1)
16" 90° DRAIN BEND
TO REMAIN, TYP.
18" BFV
TO REMAIN
DETAIL NOT USED
NOT TO SCALE
NOTES:
1. CONTRACTOR TO REMOVE AND /OR RELOCATE CONCRETE PIPE SUPPORTS AS NEEDED
TO ACCOMMODATE CONSTRUCTION AND RESTORE SUPPORT EXHIBITING EXISTING
DAMAGE.
2. CONTRACTOR TO ENSURE MINIMUM CLEARANCE ON CONCRETE SUPPORTS TO ALLOW
FOR REMOVAL OF BOLTS IN PIPE FLANGE PER SCHEDULE.
3. REMOVE 16" DRAIN PIPE AND REPLACE WITH NEW 16" D.I. PIPE (5 FT SECTION) PER
SCHEDULE DETAIL 1 OF THIS SHEET. PROTECT EXISTING CONCRETE SLAB. PLACE
NON-SHRINK GROUT AROUND PIPE PENETRATION. SEE DRAIN PIPE REPLACEMENT
SCHEDULE FOR SECTIONS TO BE REPLACED.
4. FITTINGS SHALL HAVE NUTS AND BOLTS IN ACCORDANCE WITH SECTION 39 OF THE
SPECIAL PROVISIONS. EXISTING NUTS AND BOLTS MAY BE REUSED IF THEY ARE IN
ACCEPTABLE CONDITION.
5. CONTRACTOR SHALL TEMPORARILY REMOVE ANY ELECTRICAL OR MECHANICAL
EQUIPMENT, CONDUIT, OR CABLES ATTACHED TO THE EXISTING CONCRETE PIPE
SUPPORTS AND REINSTALL ON NEW PIPE SUPPORT USING 316 SS HARDWARE.
6. BACKGROUND IMAGES ARE SHOWN FROM RECENT PROJECT RECORD DRAWINGS AND
ARE FOR GRAPHICAL REPRESENTATION ONLY. CONTRACTOR TO VERIFY EXACT
LOCATION AND ORIENTATION OF PROPOSED WORK.
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
RE
VI
SE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 9/3/2025 4:48 PM Plot By: 03761 Filename: N:\WTU\Drawings\WT0295\CV-ALL-DETL-PIPE-IMP.dwg
CV
-A
LL
-D
ET
L-
PI
PE
-IM
P.
dw g
La st
S av ed : 9
/3 /2
4:
d
By : 0
Fi le na m e:
N
W
TU
\D ra w in gs
\W T0
5\
CV
-A
LL
-D
ET
L-
PI
PE
-IM
P.
dw g
AC
AD
R el
: 2 4.
2s (L
M S
Te ch
ISSUE FOR BID
CI
TY
O F
O
KL
AH
O
M A
CI
TY
W T-
D
RA
PE
R
W
AT
ER
T
RE
AT
M
EN
T
PL
AN
T
FI
LT
ER
P
IP
E
GA
LL
ER
Y
IM
PR
O
VE
M
EN
TS
CO
C2
SE
P
N W th S t., S ui te
O kl ah om a Ci ty , O
K
Ph on e
5)
-7
W eb w w w .fr ee se
.c om
Ce rt ifi ca te o f A ut ho riz at io n:
C
A#
Ex pi ra tio n
Da te
: 0 6/
/2
O
KL
AH
O
M A
N O
DA
TE
SI
GN
ED
, S
EA
LE
D
AN
D
DA
TE
D
BY
TH
IS
D O
CU
M
EN
T
W
AS
O
RI
GI
N
AL
LY
TH
E
SE
AL
ED
, S
IG
N
ED
A
N D
DA
TE
D
DO
CU
M
EN
TS
AR
E
M
AI
N
TA
IN
ED
IN
T
HE
O
FF
IC
E O
F
FR
EE
SE
A N
D N
IC
HO
LS
A
N D
M
AY
B E
RE
VI
EW
ED
U
PO
N R
EQ
U
ES
T.
AU
TH
O
RI
ZE
D
BY
9/ 3/
M
EA
GA
N G
. B
RO
W N
P .E
CI
VI
L
FI
LT
ER
B
U
IL
DI
N
G
PI
PE
G
AL
LE
RY
DE
TA
IL
S
II
FB-C-02
SD
M M
M M
GB
SCOPE OF WORK TO BE
PERFORMED BY OTHERS
ALL NEW NUTS AND BOLTS SHALL BE 316 SS.
09/05/2025
N W th
S tr e e t, S u it e
O k la h o m a C it y
O
K
P h o n e
(4
-7
W e b w w w .f re e se .c o m
C e rt if ic a te o f A u th o ri za ti o n
C
A
E xp ir a ti o n D a te
/3
/2
36" DRESSER COUPLING
AND HANGER REPLACEMENT (TYP)
NOT TO SCALE
REMOVE AND REPLACE
36" DRESSER COUPLING
REMOVE AND REPLACE 2 X 36" PIPE
HANGERS PER SCHEDULE. (TYP)
REPAIR AND RECOAT
SUPPORTS WITH SYSTEM
NO. 8 PER SECTION 09 96
00.01
CONCRETE FLUME
HANGER REPAIR
NOT TO SCALE
REPAIR AND RECOAT SUPPORTS
WITH SYSTEM NO. 8 PER
SECTION 09 96 00.01
REPAIR AND RECOAT
SUPPORTS WITH SYSTEM NO.
8 PER SECTION 09 96 00.01
NOTES FOR DETAIL 2:
FLUME SUPPORT REPAIRS:
1. CONTRACTOR TO REMOVE EXISTING COATING, PROVIDE SURFACE REPAIR AS NEEDED,
AND RECOAT EXISTING STEEL SUPPORTS FOR CONCRETE FLUME.
2. CONCRETE FLUME IS LOCATED DIRECTLY WEST OF FILTER #7.
3. CONTRACTOR TO PROVIDE TEMPORARY SUPPORTS AS NEEDED DURING
CONSTRUCTION.
4. CONTRACTOR TO REPLACE DRESSER COUPLINGS AND HANGERS PER SECTION 33 01 03
PER SCHEDULE ON SHEET FB-C-01.
5. BACKGROUND IMAGES ARE SHOWN FROM RECENT PROJECT RECORD DRAWINGS
AND ARE FOR GRAPHICAL REPRESENTATION ONLY. CONTRACTOR TO VERIFY EXACT
LOCATION AND ORIENTATION OF PROPOSED WORK.
SHEET
SEQ.
th is sh ee t, ad ju st sc al e.
dr aw in g.
If n ot o ne in ch o n
Ba r i s o ne in ch o n or ig
E N
O
. VE
RI
FY
S
CA
LE
DA
TE
BY
F&
N
JO
B N
O
FI
LE
N
AM
E
CH
EC
KE
D
RE
VI
SE
D
DR
AW
N
DE
SI
GN
ED
DA
TE
Plot Date: 9/3/2025 4:48 PM Plot By: 03761 Filename: N:\WTU\Drawings\WT0295\CV-ALL-DETL-PIPE-IMP.dwg
CV
-A
LL
-D
ET
L-
PI
PE
-IM
P.
dw g
La st
S av ed : 9
/3 /2
4:
d
By : 0
Fi le na m e:
N
W
TU
\D ra w in gs
\W T0
5\
CV
-A
LL
-D
ET
L-
PI
PE
-IM
P.
dw g
AC
AD
R el
: 2 4.
2s (L
M S
Te ch
ISSUE FOR BID
CI
TY
O F
O
KL
AH
O
M A
CI
TY
W T-
D
RA
PE
R
W
AT
ER
T
RE
AT
M
EN
T
PL
AN
T
FI
LT
ER
P
IP
E
GA
LL
ER
Y
IM
PR
O
VE
M
EN
TS
CO
C2
SE
P
N W th S t., S ui te
O kl ah om a Ci ty , O
K
Ph on e
5)
-7
W eb w w w .fr ee se
.c om
Ce rt ifi ca te o f A ut ho riz at io n:
C
A#
Ex pi ra tio n
Da te
: 0 6/
/2
O
KL
AH
O
M A
N O
DA
TE
SI
GN
ED
, S
EA
LE
D
AN
D
DA
TE
D
BY
TH
IS
D O
CU
M
EN
T
W
AS
O
RI
GI
N
AL
LY
TH
E
SE
AL
ED
, S
IG
N
ED
A
N D
DA
TE
D
DO
CU
M
EN
TS
AR
E
M
AI
N
TA
IN
ED
IN
T
HE
O
FF
IC
E O
F
FR
EE
SE
A N
D N
IC
HO
LS
A
N D
M
AY
B E
RE
VI
EW
ED
U
PO
N R
EQ
U
ES
T.
AU
TH
O
RI
ZE
D
BY
9/ 3/
M
EA
GA
N G
. B
RO
W N
P .E
CI
VI
L
FI
LT
ER
B
U
IL
DI
N
G
PI
PE
G
AL
LE
RY
DE
TA
IL
S
III
FB-C-03
SD
M M
M M
GB
BACKGROUND IMAGES ARE SHOWN FROM RECENT PROJECT RECORD DRAWINGS
AND ARE FOR GRAPHICAL REPRESENTATION ONLY. CONTRACTOR TO VERIFY EXACT
LOCATION AND ORIENTATION OF PROPOSED WORK.
09/05/2025
N W th
S tr e e t, S u it e
O k la h o m a C it y
O
K
P h o n e
(4
-7
W e b w w w .f re e se .c o m
C e rt if ic a te o f A u th o ri za ti o n
C
A
E xp ir a ti o n D a te
/3
/2
5. CONTRACTOR REPLACE STEEL SUPPORTS IF CORROSION IS EXCESSIVE TO THE EXTENT
REPAIRS ARE NOT POSSIBLE AS DETERMINED BY OWNER AND ENGINEER.
TT
T
T
12 2
GENERAL NOTES
1 REFER TO G-G-08 HVAC FOR LEGEND, GENERAL NOTES AND ABBREVIATIONS.
2 REFER TO G-G-09 FOR PLUMBING LEGEND, GENERAL NOTES AND SCHEDULES.
3 REFER TO DIVISION 23 FOR TECHNICAL SPECIFICATIONS.
4 REFER TO ELECTRICAL DRAWINGS FOR POWER ROUTING/CONNECTION TO MECHANICAL EQUIPMENT.
5 ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL CONDUIT FOR ALL CONTROL WIRING. COORDINATE WITH
CONTROLS/MECHANICAL CONTRACTOR FOR EQUIPMENT AND DEVICE PLACEMENT.
6 THE CONTRACTORS ARE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES AND FINISHES NOT BEING REPLACED OR
REMOVED.
7 CONTRACTORS TO FIELD VERIFY EXISTING EQUIPMENT AND INSTALLATION OF NEW EQUIPMENT, CONTROLS, WIRING, AND SUPPORTS.
AVOID CONFLICT WITH EXISTING TRADES.
8 INSTALL ALL EQUIPMENT AND ACCESSORIES PER MANUFACTURER REQUIREMENTS.
EF-1
SF-1
EF-2
GUH-1
1 GUH-5
1"ø
736' - 8"
G G
G G 1/2"ø
3/4"ø12
(TYP OF 18)
14 14
1 1/4"ø
GUH-3
GUH-4
10 10
EXISTING
WQ PANEL
(TYP)
GUH-2
11 11 1 1/4"ø
/2
"ø
1/2"ø1/2"ø
3/4"ø
1/2"ø
1"ø
GG G
NORTH
SHEET
SEQ.
F
N J
O B
N O
D A
T E
D E
S
IG
N E
D
D R
A W
N
R E
V
IS
E D
C H
E C
K E
D
F
IL
E N
A M
E V
E R
IF
Y
S C
A
LE
B a r is o n e i n ch o n o ri g in a l d ra w in g
I f n o t o n e i n ch s h e e t, a d ju st s ca le
Plot Date:
N W th
S tr e e t, S u it e
O k la h o m a C it y
O
K
P h o n e
(4
-7
W e b w w w .f re e se .c o m
C e rt if ic a te o f A u th o ri za ti o n
C
A
E xp ir a ti o n D a te
/3
/2
C
IT
Y O
F O
K
LA
H O
M A
C
IT
Y
W T
-0
D R
A P
E R
W A
T E
R T
R E
A T
M E
N T
P
LA
N T
F
IL
T E
R P
IP
E
G A
LL
E
R Y
I M
P R
O V
E M
E N
T S
C O
C
S E
P
9/4/2025 3:50:55 PM
ISSUE FOR BID
F
LO
O R
P
LA
N
FB-H-01
D C
A
D C
A
W A
Y
H V
A C
-C O
C
-F
IL
R
.R V
T
H V
A C
F
IL
T E
R B
U
IL
D
IN
G P
IP
E
G A
LL
E
R Y
1" = 30'-0"
1 PIPING GALLERY DEMOLITION PLAN
1" = 30'-0"
2 PIPING GALLERY FLOOR PLAN
1 EXISTING FAN TO REMAIN, MECHANICAL CONTRACTOR TO REPROGRAM AND REBALANCE THE FAN TO EXHAUST 9,000 CFM. FAN SHALL BE CONTROLLED BY LOCAL SWITCH.
2 DEMOLISH EXISTING FAN AND ASSOCIATED CONTROLS, ACCESSORIES, AND SUPPORTS.
3 PROVIDE NEW SUPPLY FAN (SF-1) WITH MOTORIZED DAMPER. USE EXISTING DECK OPENING, REPAIR AS NECESSARY. INTERLOCK DAMPER WITH FAN. FAN SHALL BE CONTROLLED BY LOCAL
SWITCH.
4 PROVIDE NEW EXHAUST FAN (EF-1) WITH MOTORIZED DAMPER. USE EXISTING DECK OPENING, REPAIR AS NECESSARY. INTERLOCK DAMPER WITH FAN. FAN SHALL BE CONTROLLED BY LOCAL
SWITCH.
5 PROVIDE MANUAL SWITCH FOR FAN OPERATION IN PIPING GALLERY. INSTALL BOTTOM OF SWITCH AT 48" AFF.
6 PROVIDE GAS-FIRED UNIT HEATER. INSTALL BOTTOM OF HEATER 12'-0" AFF. PROVIDE AND ROUTE TYPE B VENT UP THROUGH SLAB/CEILING AND ROOF AND TERMINATE ON ROOF, PER
MANUFACTURER REQUIREMENTS. PLACEMENT IS GENERAL, MECHANICAL CONTRACTOR TO FIELD VERIFY AND COORDINATE EXACT LOCATION AND AVOID CONFLICTS.
7 PROVIDE GAS-FIRED UNIT HEATER. INSTALL BOTTOM OF HEATER 10'-0" AFF. PROVIDE AND ROUTE TYPE B VENT UP THROUGH SLAB AND TERMINATE ABOVE GRADE, PER MANUFACTURER
REQUIREMENTS. PLACEMENT IS GENERAL, MECHANICAL CONTRACTOR TO FIELD VERIFY AND COORDINATE EXACT LOCATION AND AVOID CONFLICTS.
8 PROVIDE GAS-FIRED UNIT HEATER. INSTALL BOTTOM OF HEATER 10'-0" AFF. PROVIDE AND ROUTE TYPE B VENT UP THROUGH SLAB AND TERMINATE ABOVE GRADE, PER MANUFACTURER
REQUIREMENTS. VENT SHALL TERMINATE A MINIMUM OF 3'-0" ABOVE SF-1 INLET. PLACEMENT IS GENERAL, MECHANICAL CONTRACTOR TO FIELD VERIFY AND COORDINATE EXACT LOCATION
AND AVOID CONFLICTS.
9 ROUTE UNDERGROUND TO EXISTING GAS METER AT ADMIN BUILDING. ESTIMATED GAS CAPACITY IS 315 CFH AND PRESSURE IS 14" WC. CONFIRM WITH LOCAL NATURAL GAS PROIVDER THAT
GAS PRESSURE AND CAPACITY CAN ACCOMODATE THE NEW DEMAND.
10 PROVIDE GAS PIPING APPROXIMATELY 14' - 0" AFF. ROUTE AROUND ANY OBSTRUCTIONS UNLESS INDICATED ON PLANS OTHERWISE. PROVIDE SHUT-OFF VALVE, DIRT-LEG, AND FLEX
CONNECTION TO GAS HEATERS PER MANUFACTURER RECOMMENDATIONS.
11 PROVIDE THERMOSTAT FOR GAS-FIRED UNIT HEATER. INSTALL BOTTOM OF THERMOSTAT 4'-0" AFF.
12 EXISTING 36" CI INFLUENT PIPE (TYP). CENTERLINE APPROX. 11'-0" AFF. FIELD VERIFY FOR EXACT LOCATION.
13 EXISTING 24" BACK WASH WATER PIPE. CENTERLINE APPROX. 15'-6" AFF. FIELD VERIFY FOR EXACT LOCATION.
14 EXISTING 12" SURFACE WASH PIPE. CENTERLINE APPROX. 16'-0" AFF. FIELD VERIFY FOR EXACT LOCATION.
NOTES BY SYMBOL " "
0 30' 60'
SCALE IN FEET
10' 20'
N O
IS
S U
E B
Y D
A T
E
/0
4/
AIR FLOW
ACCESS
PANEL
HEATER
RUBBER-IN SHEAR
VIBRATION
ISOLATORS
CONCRETE SLAB OR DECK
MANUAL SHUT-OFF
VALVE
DRIP LEG
GAS SUPPLY PIPING.
SECURE PIPE TO
STRUCTURE
APPROVED FLEXIBLE
CONNECTOR
NOTES:
1. CONTRACTOR SHALL ABIDE BY ALL MANUFACTURER'S UNIT HEATER, GAS
PIPING AND VENT SYSTEM INSTALLATION REQUIREMENTS.
TEE WITH DRIP LEG
AND CLEANOUT CAP
12" MINIMUM
REFER TO DRAWINGS FOR
TERMINATION LOCATIONS.
INSTALL BOTTOM OF
TERMINAL CAP A MINIMUM
OF 48" ABOVE SLAB/ROOF
UNLESS INDICATED
OTHERWISE
SLEEVE
THREADED ROD
FLASHING COLLAR
COUNTER FLASHING
LISTED TERMINAL CAP
M
IN
TYPE "B" VENT
EXISTING CONCRETE SLAB
EXISTING BUILDING
OPENING. FIELD VERIFY
DIMENSIONS AND MODIFY
AS NECESSARY
M
TALL BASE WITH
FACTORY-FURNISHED
MOTORIZED DAMPER
BIRD SCREEN
REMOVEABLE
(ACCESSIBLE)
FAN HOOD
ACCESS DOOR
WASHABLE ALUMINUM FILTERS AS
REQUIRED (REFER TO FAN
SCHEDULE)
NEW CONCRETE
CURB
PREFABRICATED
ROOF CURB
1/2" THICK CLOSED-CELL
NEOPRENE SEAL
3/8" HILTI KWIK BOLT 3 EXPANSION ANCHORS
OR EQUAL. MINIMUM 2 1/2" EMBEDMENT.
INSTALL MANUFACTURER RECOMMENDED
QUANITY OF FASTENERS ON FLANGE CORNERS
AND SIDES
MOUNTING FLANGE
M
IN
BELT OR DIRECT DRIVE FAN
(REFER TO FAN SCHEDULE)
SUPPLY OR
EXHAUST
(REFER TO FAN
SCHEDULE)
M
IN
IN
(N
T E
DETAIL NOTES:
1. COORDINATE REQUIRED CURB HEIGHT WITH EQUIPMENT
MANUFACTURER PRIOR TO FABRICATION OR CONSTRUCTION.
4 1/2" MIN
4 1/2" MIN
C
LR
E M
B E
D
#4 ADHESIVE
ANCHOR @ 12"C/C
AROUND PERIMETER
OF EXIST OPNG W/
3" EMBED
SHEET
SEQ.
F
N J
O B
N O
D A
T E
D E
S
IG
N E
D
D R
A W
N
R E
V
IS
E D
C H
E C
K E
D
F
IL
E N
A M
E V
E R
IF
Y
S C
A
LE
B a r is o n e i n ch o n o ri g in a l d ra w in g
I f n o t o n e i n ch s h e e t, a d ju st s ca le
Plot Date:
N W th
S tr e e t, S u it e
O k la h o m a C it y
O
K
P h o n e
(4
-7
W e b w w w .f re e se .c o m
C e rt if ic a te o f A u th o ri za ti o n
C
A
E xp ir a ti o n D a te
/3
/2
C
IT
Y O
F O
K
LA
H O
M A
C
IT
Y
W T
-0
D R
A P
E R
W A
T E
R T
R E
A T
M E
N T
P
LA
N T
F
IL
T E
R P
IP
E
G A
LL
E
R Y
I M
P R
O V
E M
E N
T S
C O
C
S E
P
9/4/2025 3:50:56 PM
ISSUE FOR BID
D E
T A
IL
S
E
Q U
IP
M
E N
T S
C H
E D
U
LE
S
FB-H-02
D C
A
D C
A
W A
Y
H V
A C
-C O
C
-F
IL
R
.R V
T
H V
A C
F
IL
T E
R B
U
IL
D
IN
G P
IP
E
G A
LL
E
R Y
REMARKS:
1. PROVIDE WITH ALL ACCESSORIES FOR ROOF/SLAB MOUNTING. FAN SHALL HAVE A TALL BASE WITH DAMPER ACCESS AND ROOF CURB.
2. PROVIDE WITH ALUMINUM BIRD SCREEN.
3. PROVIDE WITH WASHABLE ALUMINUM MESH FILTERS.
4. PROVIDE WITH FACTORY-FURNISHED NEMA 4X DISCONNECT.
5. PROVIDE WITH SPEED CONTROLLER.
6. PROVIDE WITH HI-PRO POLYESTER (OR APPROVED EQUAL) COATING.
7. PROVIDE WITH MOTORIZED DAMPER.
8. PROVIDE WITH FACTORY SINGLE POINT WIRING AND FACTORY HARD-WIRED STEP-DOWN TRANSFORMER FOR 120 VAC/1 PH DAMPER ACTUATOR.
FAN SCHEDULE
MARK SERVICE TYPE DRIVE FEI CFM
ESP (IN
W.G)
MAX.
SONES HP FAN RPM
UNIT ELECTRICAL WEIGHT
(LBS) MANUFACTURER/MODEL NOTESVOLTAGE PHASE MCA MOCP
EF-1 EXHAUST ROOF MOUNTED, PROPELLER HOODED BELT 1.60 9,000 0.29 24 1 1/2 891 460 3 3.0 15 700 GREENHECK/RBCE-3H36 1,2,4,5,6,7,8
SF-1 SUPPLY ROOF MOUNTED, PROPELLER HOODED BELT 1.15 12,000 0.27 35 3 1016 460 3 4.8 15 700 GREENHECK/RBCF-3H36 1,2,3,4,5,6,7,8
GAS-FIRED UNIT HEATER SCHEDULE
MARK TYPE
INPUT
(MBH)
OUTPUT
(MBH)
AIRFLOW
(CFM)
THROW
(FT)
UNIT ELECTRICAL WEIGHT
(LBS) MANUFACTURER/MODEL NOTESHP VOLTAGE PHASE
GUH-1 NATURAL GAS 60.0 49.8 769 39 0.06 115 1 71 REZNOR/UDXC-60 1,2,3,4,5,6,7
GUH-2 NATURAL GAS 75.0 62.2 961 52 0.06 115 1 76 REZNOR/UDXC-75 1,2,3,4,5,6,7
GUH-3 NATURAL GAS 60.0 49.8 769 39 0.06 115 1 71 REZNOR/UDXC-60 1,2,3,4,5,6,7
GUH-4 NATURAL GAS 60.0 49.8 769 39 0.06 115 1 71 REZNOR/UDXC-60 1,2,3,4,5,6,7
GUH-5 NATURAL GAS 60.0 49.8 769 39 0.06 115 1 71 REZNOR/UDXC-60 1,2,3,4,5,6,7
REMARKS:
1. REFER TO ELECTRICAL DRAWINGS FOR UNIT DISCONNECTS.
2. PROVIDE APPROPRIATE ACCESSORIES TO SUPPORT HEATER FROM CEILING.
3. PROVIDE WITH VIBRATION ISOLATION KIT.
4. PROVIDE WITH VERTICAL AND HORIZONTAL DEFLECTOR BLADES.
5. UNIT SHALL TAKE COMBUSTION AIR FROM SPACE DIRECTLY (POWER-VENTED).
6. PROVIDE REMOTE NEMA 4X 24VAC THERMOSTAT, SETPOINT 55°F (ADJ.).
7. MAINTAIN MINIMUM 18" SERVICE CLEARANCE ON ALL SIDES AND COMBUSTIBLE CLEARANCE AS SPECIFIED BY MANUFACTURER.
NOT TO SCALE
1 GAS-FIRED UNIT HEATER DETAIL
NOT TO SCALE
2 HOODED AXIAL SUPPLY/EXHAUST FAN DETAIL
N O
IS
S U
E B
Y D
A T
E
/0
4/
NOTE:
X
X
CLASS I, DIV.1,
GROUP D
THREE 4-INCH CONDUITS
INDICATES THAT ALL ELECTRICAL EQUIPMENT AND
MATERIALS INSTALLED WITHIN THE ROOM OR AREA
IN WHICH THIS NOTATION APPEARS SHALL BE OF
NEMA 12 CONSTRUCTION UNLESS OTHERWISE NOTED
INDICATES THAT ALL ELECTRICAL EQUIPMENT AND
MATERIALS INSTALLED WITHIN THE ROOM OR AREA
IN WHICH THIS NOTATION APPEARS SHALL BE OF
NEMA 4X CONSTRUCTION UNLESS OTHERWISE NOTED
DENOTES A QUANTITY OF TWO INSTRUMENT CABLES.
EACH CONSISTS OF TWO NO.16 AWG CONDUCTORS
CABLE TAG FOUR #14 CONTROL OR POWER
CONDUCTORS, ONE #14 GROUND CONDUCTOR. ALL
CONDUCTORS IN A 3/4" CONDUIT. TWO OF THE FOUR
#14 CONTROL OR POWER CONDUCTORS ARE SPARE.
4 #14, #14G., 3/4"C.
(2 #14 SPARE)
METER
WM - WATTMETER
WHM - WATTHOUR METER
WHDM - WATTHOUR DEMAND METER
WHDR - WATTHOUR DEMAND RECORDER
PF - POWER FACTOR METER
ETM - ELAPSED TIME METER
TRANSDUCER
AX - CURRENT TRANSDUCER
WX - WATT TRANSDUCER
RELAY, NO. AS INDICATED
25 - SYNCHRONISM CHECK RELAY
27 - UNDER VOLTAGE RELAY
38 - BEARING PROTECTIVE DEVICE
40 - LOSS OF EXCITATION RELAY
42 - RUNNING CONTACTOR/PILOT RELAY
46 - REVERSE PHASE/PHASE BALANCE/CURRENT RELAY
47 - PHASE SEQUENCE VOLTAGE RELAY
48 - MACHINE OR TRANSFORMER THERMAL RELAY
50 - INSTANTANEOUS OVERCURRENT RELAY
50G - INSTANTANEOUS GROUND
51 - TIME OVER CURRENT RELAY, GROUNDING RESISTOR TYPE
51N - TIME OVERCURRENT RELAY, RESIDUAL TYPE
51V - TIME OVERCURRENT RELAY WITH VOLTAGE
RESTRAINT
59 - OVER VOLTAGE RELAY
60 - NEGATIVE SEQUENCE VOLTAGE RELAY
62 - TIME DELAY RELAY
63 - OVER PRESSURE RELAY
67 - AC DIRECTIONAL OVERCURRENT RELAY
83 - AUTOMATIC SELECTIVE CONTROL OR TRANSFER RELAY
86 - LOCKING-OUT RELAY
87 - DIFFERENTIAL PROTECTIVE RELAY
B - SUFFIX INDICATES "BUS"
G - SUFFIX INDICATES "GENERATOR"
GF - GROUND FAULT
IR - INTERPOSING RELAY
PFR - PHASE FAILURE, PHASE REVERSAL, UNDERVOLTAGE,
OVERVOLTAGE RELAY
ST - SHUNT TRIP
T - SUFFIX INDICATES "TRANSFORMER"
TRP CAP - CAPACITOR TRIP
X - SUFFIX INDICATES "AUXILIARY"
MC1-XXX
TR TRIAD
PHOTOCELLPC
AIC
C/C CENTER TO CENTER
DP
FT
EXIST.
EUC
HP
HTP
GA.
GFS
DIFFERENTIAL PRESSURE
HORSEPOWER
HEATER
ELECTRIC UTILITY CO.
GAUGE
FEET
EXISTING
GROUND FAULT SENSING
ID
JB
LED
KW
KVA
IRP
MFR'S
MCB
MANUFACTURER'S
KILOWATT
MAIN CIRCUIT BREAKER
LIGHT EMITTING DIODE
KILOVOLT-AMPERE
INTERPOSING RELAY PANEL
JUNCTION BOX
INTERNAL DIAMETER
AMPERES INTERRUPTING CAPACITY
PREWIRED
OD
NF
MPR
PL.
PH
PLC
P POLE
OUTSIDE DIAMETER
NON-FUSED
MOTOR PROTECTION RELAY
PHASE
PLATE
REC.
RTU
RTD
REQD.
SHLD. OR SH
SN OR S/N
STC
STA.
CIRCUIT RECLOSURE
REMOTE TERMINAL UNIT
SOLID NEUTRAL
REQUIRED
SHIELD OR SHIELDED
STATION
SIGNAL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .