WT-0295 - Plans.pdf

PDF 19 MB Posted

Attached to
Filter Pipe Gallery Improvements
Solicitation number
WT-0295
Issued by
Oklahoma County, Hobart City, Oklahoma

About this file

This document is a comprehensive bid set for the City of Oklahoma City Water Utilities Trust, specifically for Filter Pipe Gallery Improvements at the Draper Water Treatment Plant. The project (Project No. WT-0295) involves extensive renovations to the existing filter pipe gallery, including removing and replacing drain pipes, Dresser couplings, concrete pipe supports, pipe support hangers, and concrete flume support hangers. The improvements also include HVAC modifications such as installing new supply and exhaust fans, gas-fired unit heaters, and lighting upgrades. The project will involve coating existing pipes, repairing concrete supports, and upgrading electrical systems, with work to be performed in the Filter Building Pipe Gallery.

The bid documents indicate this is an "Issue for Bid" set, suggesting the project is currently in the procurement phase. The scope encompasses electrical, mechanical, and civil work, with detailed specifications for equipment replacement and system upgrades. While specific budget details are not explicitly stated, the comprehensive nature of the improvements suggests a significant capital investment. The project appears to be funded through the Oklahoma City Water Utilities Trust, with work focused on maintaining and modernizing critical infrastructure at the Draper Water Treatment Plant. The bid set includes extensive technical details, equipment schedules, floor plans, electrical and HVAC diagrams, and specific requirements for demolition, installation, and system integration.

View the file

Other files

File Type Posted
Anti Noncollusion Affidavit.pdf PDF
Business Relationship Affidavit.pdf PDF
WT-0295- Specs.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GE

N

ER

AL

GE

N

ER

AL

N O

TE

S

AN

D

SH

EE

T

IN

DE

X

G-G-02

SD

M M

M M

GB

SHEET

SEQ.

th is sh ee t, ad ju st sc al e.

dr aw in g.

If n ot o ne in ch o n

Ba r i s o ne in ch o n or ig in al

IS

SU

E N

O

. VE

RI

FY

S

CA

LE

DA

TE

BY

F&

N

JO

B N

O

FI

LE

N

AM

E

CH

EC

KE

D

RE

VI

SE

D

DR

AW

N

DE

SI

GN

ED

DA

TE

Plot Date: 9/3/2025 4:48 PM Plot By: 03761 Filename: N:\WTU\Drawings\WT0295\GN-ALL-SHEET INDEX.dwg

GN

-A

LL

-S

HE

ET

IN

DE

X.

dw g

La st

S av ed : 9

/3 /2

4:

P M

Sa ve d

By : 0

Fi le na m e:

N

W

TU

\D ra w in gs

\W T0

5\

GN

-A

LL

-S

HE

ET

IN

DE

X.

dw g

AC

AD

R el : 2

4.

2s

(L M

S Te ch

ISSUE FOR BID

CI

TY

O F

O

KL

AH

O

M A

CI

TY

W T-

D

RA

PE

R

W

AT

ER

T

RE

AT

M

EN

T

PL

AN

T

FI

LT

ER

P

IP

E

GA

LL

ER

Y

IM

PR

O

VE

M

EN

TS

CO

C2

SE

P

N W th S t., S ui te

O kl ah om a Ci ty , O

K

Ph on e

5)

-7

W eb w w w .fr ee se

.c om

Ce rt ifi ca te o f A ut ho riz at io n:

C

A#

Ex pi ra tio n

Da te

: 0 6/

/2

GENERAL NOTES

1. THE FOLLOWING NOTES ARE GENERAL AND APPLY TO ALL SHEETS OF

THESE CONTRACT DOCUMENTS AS IF THEY WERE WRITTEN IN THEIR

ENTIRETY ON EACH SHEET.

2. EXISTING STRUCTURES, UTILITIES AND PIPING ARE SHOWN FROM

AVAILABLE RECORDS AT THE TIME THIS PLAN WAS PREPARED. THE

CONTRACTOR SHALL BE RESPONSIBLE TO DETERMINE AND VERIFY THE

LOCATION AND DEPTH OF ALL EXISTING STRUCTURES, UTILITIES AND

PIPING WITHIN THE CONSTRUCTION AREA PRIOR TO THE BEGINNING OF

CONSTRUCTION. ANY DAMAGE TO THE EXISTING STRUCTURES, UTILITIES

AND PIPING SHALL BE RESTORED AT NO ADDITIONAL COST TO THE

OWNER.

3. PRIOR TO FABRICATION OF NEW PIPING, INCLUDING SPECIAL FITTINGS

AND EXCAVATION FOR NEW STRUCTURES, ELECTRICAL CONDUIT AND/OR

OTHER ROPOSED UTILITIES, CONTRACTOR SHALL BE RESPONSIBLE FOR

VERIFYING THE LOCATION OF ALL EXISTING PIPING AND UTILITIES IN THE

CONSTRUCTION. AT TIE-IN CONNECTION LOCATIONS, VERIFY EXISTING

PIPING BEFORE FABRICATION OF NEW PIPING. THE CONTRACTOR SHALL

INCLUDE COST IN HIS BID FOR TEMPORARILY RELOCATING AND

REINSTALLING EXISTING UTILITIES AS REQUIRED FOR CONSTRUCTION OF

PROPOSED ITEMS.

4. PIPES SHALL BE ROUTED AS SHOWN UNLESS MINOR REVISIONS ARE

NECESSARY TO AVOID EXISTING PIPES, STRUCTURES, ETC. CONTRACTOR

SHALL BE RESPONSIBLE FOR FURNISHING ALL FITTINGS AND ADAPTERS

REQUIRED TO MAKE THE ROUTING CHANGES. CONTRACTOR SHALL

INCLUDE COST FOR THIS IN THE BID.

5. PROVIDE PIPE, EQUIPMENT, FITTINGS, ADAPTERS, SUPPORTS AND

APPURTENANCES REQUIRED FOR A COMPLETE AND WORKING SYSTEM.

6. PROVIDE RESTRAINED JOINTS AND CONCRETE ENCASEMENT AT ALL

VERTICAL/HORIZONTAL BENDS AND CONCRETE ENCASEMENT SHALL BE AS

SHOWN IN THE STANDARD CIVIL DETAILS.

7. DO NOT EXCEED 75% OF MANUFACTURER'S RECOMMENDED MAXIMUM

DEFLECTION FOR PIPE JOINTS, UNLESS NOTED OTHERWISE.

8. UTILITIES DESIGNATED TO BE DEMOLISHED SHALL BE COMPLETELY

REMOVED, UNLESS OTHERWISE APPROVED BY THE ENGINEER.

9. CONTRACTOR SHALL VERIFY THAT PIPING OR STRUCTURES SHOWN TO BE

ABANDONED OR AS ABANDONED PREVIOUSLY IS NO LONGER IN SERVICE.

LINES IN SERVICE SHALL BE MAINTAINED UNTIL NO LONGER REQUIRED BY

THE OWNER.

10. EXISTING PIPES ABANDONED IN PLACE OR TO BE REMOVED MAY NOT BE

SHOWN. WHERE PIPING TO BE ABANDONED MUST REMAIN IN SERVICE

UNTIL COMPLETION OF OTHER PHASE WORK, AND IF CONFLICTS WITH

NEW PIPING, TEMPORARILY RELOCATE TO MAINTAIN SERVICE.

11. CONTRACTOR SHALL REROUTE THE EXISTING PIPING IF REQUIRED TO

AVOID THE PROPOSED STRUCTURES. THE EXISTING PIPE SHALL REMAIN IN

SERVICE UNTIL NEW PIPING IS READY TO BE PLACED INTO SERVICE.

DOWNTIME SHALL BE A MAXIMUM OF 2 HOURS, UNLESS SPECIFIED IN

THE CONTRACT DOCUMENTS OR SHOWN OTHERWISE. ALL REMAINING

PIPING, WHETHER IN SERVICE OR ABANDONED, SHALL BE NOTED ON THE

RECORD DRAWINGS.

12. PROTECT M.J. HARDWARE FROM BEING ENCASED OR COVERED WITH

CONCRETE ENCASEMENT DURING INSTALLATION OF CONCRETE, UNLESS

NOTED OTHERWISE.

13. THE CONTRACTOR SHALL TAKE SPECIAL PRECAUTIONS IN THE VICINITY OF

ANY OVERHEAD ELECTRIC LINES. CONTRACTOR SHALL ABIDE BY THE MOST

RECENT NATIONAL ELECTRIC CODE AND ANY REQUIREMENT BY OWNER

OF ELECTRIC LINES.

14. PROVIDE ALL SHEETING/SHORING REQUIRED TO PROTECT EXISTING

STRUCTURES, PIPES AND FACILITIES.

15. SOME DIMENSIONS AND ELEVATIONS RELATED TO EXISTING STRUCTURES

WERE OBTAINED FROM PREVIOUS CONSTRUCTION/RECORD DRAWINGS.

ALL EXISTING DIMENSIONS AND ELEVATIONS SHALL BE VERIFIED IN THE

FIELD BY THE CONTRACTOR.

16. CONTRACTOR SHALL CONTACT THE PROPER UTILITY REPRESENTATIVE FOR

QUESTIONS OR COORDINATION OF CONSTRUCTION RELATED TO EXISTING

UTILITIES.

17. CONTRACTOR SHALL COMPLETELY REMOVE AND PROPERLY DISPOSE OF

ALL STRUCTURES DESIGNATED FOR DEMOLITION AS SOON AS POSSIBLE.

18. ALL NEW UNISTRUT, ANCHORS, SUPPORT SYSTEMS AND FASTENING

HARDWARE SHALL BE 316 STAINLESS STEEL, UNLESS OTHERWISE NOTED.

19. MECHANICAL AND ELECTRICAL EQUIPMENT, SUPPORTS, ANCHORAGES,

OPENINGS, RECESSES AND REVEALS NOT SHOWN ON THE DRAWINGS BUT

REQUIRED BY THE CONTRACT DOCUMENTS SHALL BE PROVIDED.

20. EXISTING VALVES, GATES, AND CONSTRUCTION EXPANSION JOINTS MAY

LEAK TO A CERTAIN EXTENT WHEN IN A CLOSED POSITION. CONTRACTOR

SHALL PROVIDE MEANS AND EQUIPMENT NECESSARY TO CONTROL

LEAKING WATER AS NEEDED TO PERMIT CONSTRUCTION.

21. GALVANIZED STEEL PRODUCTS SHALL NOT BE USED FOR PLANT

STRUCTURE AND EQUIPMENT CONSTRUCTION.

22. EXPOSED STEEL PRODUCTS SHALL BE PROPERLY COATED IN ACCORDANCE

WITH SECTION 09 96 00.01 HIGH PERFORMANCE COATINGS.

23. ALL DEMOLISHED STRUCTURES AND NON-SALVAGED EQUIPMENT AS

WELL AS EXCESS EXCAVATED SOILS SHALL BE REMOVED AND DISPOSED OF

AS SOON AS POSSIBLE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL

LAWS, REGULATIONS AND OTHER ORDINANCES AT NO ADDITIONAL COST

TO OWNER. FURNISH WRITTEN VERIFICATION FROM THE OWNER OF THE

DISPOSAL SITE AUTHORIZING THE CONTRACTOR TO DISPOSE OF

MATERIALS AT THAT LOCATION AND WRITTEN VERIFICATION FROM THE

OWNER OF THE DISPOSAL SITE AFTER PLACEMENT THAT IT IS ACCEPTABLE.

24. ALL ELEVATIONS SHALL BE VERIFIED.

25. EXCAVATION ADJACENT TO EXISTING UTILITIES TO REMAIN OR CROSSING

UTILITIES SHALL BE EXCAVATED BY HAND AND IN SUCH A MANNER AS TO

AVOID DAMAGE TO EXISTING FACILITIES.

26. ANY PLANT UTILITY AND PIPING, COMMUNICATION AND ELECTRICAL OR

INSTRUMENTATION WIRING AND CONDUIT DAMAGED DURING

CONSTRUCTION SHALL BE REPAIRED AND PLACED BACK IN SERVICE BY THE

CONTRACTOR ON THE SAME DAY THAT THE DAMAGE OCCURED. AFTER 24

HOURS OUT OF SERVICE, OWNER WILL HAVE THE OPTION OF HAVING THE

REPAIRS MADE BY A SEPARATE CONTRACTOR AND DEDUCTING THE COST

OF SAID REPAIRS FROM THE CONTRACT AMOUNT THROUGH THE PAY

ESTIMATE.

27. ALL DEMOLISHED PIPING AND APPURTENANCES, CONDUITS, ELECTRIC

WIRING AND EQUIPMENT ARE SUBJECT TO BE DISPOSED OF BY

CONTRACTOR. ALL DISPOSED EQUIPMENT AND STRUCTURES WILL BE

REMOVED FROM THE SITE BY THE CONTRACTOR.

28. CONTRACTOR SHALL REPAIR ANY EXISTING PAVEMENT DEMOLISHED FOR

UTILITY INSTALLATION OR MODIFICATION WORK. THE PAVEMENT SHALL

BE RETURNED TO EXISTING CONDITIONS.

29. EXISTING CONCRETE THRUST BLOCKING THAT CONFLICTS WITH NEW

CONSTRUCTION OR MODIFICATIONS SHALL BE REMOVED BY THE

CONTRACTOR. WHEN REMOVED, THE CONTRACTOR SHALL PROVIDE

TEMPORARY THRUST RESTRAINT TO THE EXISTING PIPING SYSTEM,

FITTINGS, AND/OR STRUCTURES. TO MAINTAIN CONTINUOUS OPERATION.

ONCE CONSTRUCTION IS COMPLETE, THE CONTRACTOR SHALL RESTORE

THE PREVIOUSLY EXISTING THRUST BLOCKING TO ITS ORIGINAL

CONDITION (UNDISTURBED EARTH). THE ORIGINAL CONDITION SHALL

INCLUDE PROPER THRUST RESTRAINT AND COMPACTED BACKFILL AS

DESCRIBED IN THE CONTRACT DOCUMENTS.

30. ANY EXISTING PIPING THAT IS AFFECTED BY NEW CONSTRUCTION OR

PIPING INSTALLATION, UNLESS DEMOLISHED AND REMOVED, SHALL BE

RETURNED TO ORIGINAL OR BETTER CONDITION AT NO ADDITIONAL COST

TO THE OWNER. PIPING REPAIR SHALL INCLUDE CONSIDERATION FOR

BACKFILL, ENCASEMENT, SUPPORTS, RESTRAINTS, FITTINGS, VALVES, HEAT

TRACINGS, INSULATION AND ANY TYPICAL OR SPECIAL COATINGS THAT

ARE APPLIED TO THE INTERIOR AND/OR EXTERIOR OF THE PIPING AND ITS

APPURTENANCES.

31. UNLOADING AND STORAGE OF EQUIPMENT SHALL BE THE RESPONSIBILITY

OF THE CONTRACTOR WHO SHALL INSPECT ALL EQUIPMENT FOR

APPARENT DAMAGE. EQUIPMENT WHICH IS FOUND TO BE DAMAGED

WILL NOT BE ACCEPTED UNTIL PROPERLY REPAIRED OR REPLACED BY THE

VENDOR.

32. CONTRACTOR SHALL COORDINATE WITH THE OWNER'S PROJECT TEAM ON

CONSTRUCTION SEQUENCING AND ACTIVITIES THAT IMPACT THE CRITICAL

OPERATIONS PER SPECIFICATION 01 35 00 SPECIAL PROCEDURES PRIOR TO

THE COMMENCEMENT OF ANY WORK.

GENERAL CIVIL NOTES

1. SAFETY SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE

ENGINEER SHALL NOT BE RESPONSIBLE FOR SAFETY, MEANS, OR METHODS OF

THE CONTRACTOR.

2. THE ADDRESS OF THE PROJECT SITE IS 13700 S. DOUGLAS BLVD., OKLAHOMA

CITY, OK 73165. THE SITE IS LOCATED IN OKLAHOMA COUNTY, OKLAHOMA. THE

PARCEL OF THE PROPERTY UPON WHICH THE PROJECT SITE IS LOCATED IS

INDICATED ON FEMA FIRM PANEL 40027C0205H. THE PROJECT IS NOT LOCATED

IN A FLOOD ZONE.

3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO COMMENCING WORK.

4. ANY PAVEMENT DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED TO

EQUAL OR BETTER CONDITION AT THE CONTRACTOR'S EXPENSE.

5. FINAL PAVEMENT SURFACES SHALL NOT BE PLACED UNTIL ALL MAJOR

CONSTRUCTION ACTIVITIES HAVE CONCLUDED.

6. ALL SIDEWALK, ASPHALT, AND CONCRETE PAVING REMOVED AND REPLACED

SHALL BE NEAT SAW CUT.

7. CONTRACTOR SHALL PROVIDE AND MAINTAIN POSITIVE DRAINAGE DURING

ALL PHASES OF CONSTRUCTION.

O

KL

AH

O

M A

N O

DA

TE

SI

GN

ED

, S

EA

LE

D

AN

D

DA

TE

D

BY

TH

IS

D O

CU

M

EN

T

W

AS

O

RI

GI

N

AL

LY

TH

E

SE

AL

ED

, S

IG

N

ED

A

N D

DA

TE

D

DO

CU

M

EN

TS

AR

E

M

AI

N

TA

IN

ED

IN

T

HE

O

FF

IC

E O

F

FR

EE

SE

A N

D N

IC

HO

LS

A

N D

M

AY

B E

RE

VI

EW

ED

U

PO

N R

EQ

U

ES

T.

AU

TH

O

RI

ZE

D

BY

9/ 3/

M

EA

GA

N G

. B

RO

W N

P .E

SHEET INDEX

SEQ SHEET NO. TITLE

GENERAL

1 G-G-01 COVER

2 G-G-02 SHEET INDEX

3 G-G-03 GENERAL NOTES

CIVIL

4 FB-C-01 DETAILS I

5 FB-C-02 DETAILS II

6 FB-C-03 DETAILS III

HVAC

ELECTRICAL

09/05/2025

SEQ SHEET NO. TITLE

1 G-G-01 COVER

2 G-G-02 SHEET INDEX

3 G-G-03 GENERAL NOTES

4 G-H-04 HVAC NOTES, SYMBOLS & ABBREVIATIONS

5 G-E-01 ELECTRICAL GENERAL NOTES

CIVIL

6 FB-C-01 DETAILS I

7 FB-C-02 DETAILS II

8 FB-C-03 DETAILS III

HVAC

9 FB-H-01 FLOOR PLAN

10 FB-H-02 DETAILS & EQUIPMENT SCHEDULES

ELECTRICAL

11 FB-E-01 LEGEND I

12 FB-E-02 LEGEND II

13 FB-E-03 PIPE GALLERY FLOOR PLANS

14 FB-E-04 FILTER GALLERY FLOOR PLAN

15 FB-E-05 DETAILS

16 FB-E-06 SCHEDULES I

17 FB-E-07 SCHEDULE II

GENERAL

N W th

S tr e e t, S u it e

O k la h o m a C it y

O

K

P h o n e

(4

-7

W e b w w w .f re e se .c o m

C e rt if ic a te o f A u th o ri za ti o n

C

A

E xp ir a ti o n D a te

/3

/2

SEQ SHEET NO. TITLE

1 G-G-01 COVER

2 G-G-02 GENERAL NOTES AND SHEET INDEX

3 G-G-03 ELECTRICAL GENERAL NOTES

4 G-G-08 HVAC NOTES, SYMBOLS & ABBREVIATIONS

CIVIL

5 FB-C-01 DETAILS I

6 FB-C-02 DETAILS II

7 FB-C-03 DETAILS III

HVAC

8 FB-H-01 FLOOR PLAN

9 FB-H-02 DETAILS & EQUIPMENT SCHEDULES

ELECTRICAL

10 FB-E-01 LEGEND I

11 FB-E-02 LEGEND II

12 FB-E-03 PIPE GALLERY FLOOR PLANS

13 FB-E-04 FILTER GALLERY FLOOR PLAN

14 FB-E-05 DETAILS

15 FB-E-06 SCHEDULES I

16 FB-E-07 SCHEDULE II

GENERAL

UNITDESCRIPTION

ESTIMATED QUANTITIES

A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LS

ITEM

NO.

TOTAL

QUANTITY

AS-BUILT

QUANTITY

SEE SHEET G-G-02

A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02

A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02

A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02

A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02

A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02

A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02

A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02

A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02

A-01 1FILTER BUILDING PIPE GALLERY IMPROVEMENTS LSSEE SHEET G-G-02

LEAD BASED PAINT ABATEMENT

PIPE EXTERIOR COATINGS

REMOVE AND REPLACE DRAIN PIPES

REMOVE AND REPLACE DRESSER COUPLINGS

REMOVE AND REPLACE CONCRETE PIPE SUPPORTS

REMOVE AND REPLACE PIPE SUPPORT HANGERS (2 PER EA PIPE)

REPAIR OR REPLACE CONCRETE FLUME SUPPORT HANGERS

HVAC IMPROVEMENTS

DEMO EXISTING GALLERY LIGHTING9

EA

SF

LS

LS

LS

EA

EA

EA

EA

SF

INSTALL OVERHEAD LIGHTING (LOW BAY)

18,000

18,000

72 653 4 8

A

E

B

C

D

"LP-A" "DP-T""LP-B" "LP-C" "DP-A""DP-S"

XFMR-LP-C SWBD-HQ-BXFM4-LP-A SWBD-HQ-A XFMR-LP-B SWBD-HQ-A

1" = 30'-0"

1 FILTER GALLERY FLOOR PLAN

0 30' 60'

SCALE IN FEET

10' 20'

N O

R T

H

SHEET

SEQ.

F

N J

O B

N O

D A

T E

D E

S

IG

N E

D

D R

A W

N

R E

V

IS

E D

C H

E C

K E

D

F

IL

E N

A M

E V

E R

IF

Y

S C

A

LE

B a r is o n e i n ch o n o ri g in a l d ra w in g

I f n o t o n e i n ch o n th is s h e e t, a d ju st s ca le

Plot Date:

N W th

S tr e e t, S u it e

O k la h o m a C it y

O

K

P h o n e

(4

-7

W e b w w w .f re e se .c o m

C e rt if ic a te o f A u th o ri za ti o n

C

A

E xp ir a ti o n D a te

/3

/2

C

IT

Y O

F O

K

LA

H O

M A

C

IT

Y

W T

-0

-2 P

H A

S E

I I

V A

R

IO

U S

I M

P R

O V

E M

E N

T S

A T

D R

A P

E R

W T

C O

C

S E

P T

9/5/2025 5:17:36 PM

ISSUE FOR BID

F

IL

T E

R G

A

LL

E R

Y F

LO

O

R P

LA

N

FB-E-04

M C

D

M C

D

D W

K-

E L-

C O

C

-F

IL

R

E

LE

C T

R

IC

A L

GENERAL NOTES

1. REFER TO SHEETS FB-E-05 AND FB-E-06 FOR PANEL SCHEDULES.

2. THIS SHEET IS FOR REFERENCE ONLY TO SHOW PANEL LOCATIONS.

N O

IS

S U

E B

Y D

A T

E

/0

5/

CI

TY

O

F O

KL

AH

O M

A

CI

TY

W

T-

D

RA

PE

R W

AT

ER

T

RE

AT

M

EN

T

PL

AN

T

FI

LT

ER

P

IP

E

GA

LL

ER

Y

IM

PR

O

VE

M

EN

TS

N W th

S tr e e t, S u it e

O k la h o m a C it y

O

K

P h o n e

(4

-7

W e b w w w .f re e se .c o m

C e rt if ic a te o f A u th o ri za ti o n

C

A

E xp ir a ti o n D a te

/3

/2

DEMOLITION NOTES

1. THE CONTRACTOR SHALL COORDINATE THE DEMOLITION OF THE ELECTRICAL CONDUIT, WIRE, EQUIPMENT AND DEVICES WITH THE GENERAL DEMOLITION AND SCHEDULE. THE DRAWINGS ARE

INTENDED TO CONVEY THE GENERAL NATURE AND SCOPE OF THE DEMOLITION WORK. EVERY ITEM TO BE DEMOLISHED MAY NOT BE SHOWN. FIELD VERIFY WITH OWNER PRIOR TO BID, AND INCLUDE

ALL DEMOLITION WORK IN THE CONTRACT PRICE.

2. PROVIDE TEMPORARY WIRE AND CONDUIT FOR THE EQUIPMENT WHICH MAY BE AFFECTED BY THE DEMOLITION BUT TO REMAIN IN SERVICE. WHERE NECESSARY TO MAINTAIN PLANT OPERATION, THE CONTRACTOR SHALL PROVIDE A GENERATOR OR GENERATORS TO KEEP THE PROCESS IN

OPERATION WHILE SERVICE SWITCHOVER IS BEING PERFORMED.

3. RELOCATE AND RECONNECT POWER AND CONTROL RACEWAYS AND CONDUCTORS TO EQUIPMENT

AFFECTED BY DEMOLITION WORK.

4. ALL CONDUCTORS BEING DEMOLISHED SHALL BE DISCONNECTED AND REMOVED FROM THE LOAD

TO THE SOURCE. SURFACE MOUNTED CONDUITS AND MOUNTING HARDWARE SHALL BE REMOVED.

UNDERGROUND CONDUITS WHICH ARE NOT BEING REMOVED OR NOT BEING REUSED SHALL BE

CAPPED AND TAGGED AS SPARE, WITH INFORMATION CLEARLY INDICATING THE LOCATION OF THE

OTHER END, UNLESS NOTED OTHERWISE.

5. ALL SURFACES WHERE DEMOLISHED EQUIPMENT OR CONDUIT IS REMOVED SHALL BE CLEANED, PATCHED AND PAINTED TO MATCH THE SURROUNDING SURFACE.

6. THE CONTRACTOR SHALL BE RESPONSIBLE TO CHECK THE FUNCTION AND ROUTE OF EACH

CONDUCTOR BEFORE REMOVING OR DISCONNECTING.

7. THE CONTRACTOR SHALL FIELD VERIFY PRIOR TO BID TO DETERMINE IF CONDUCTORS WHICH ARE

TO STAY IN SERVICE (NOT BEING DEMOLISHED) ARE INSTALLED IN A COMMON CONDUIT WITH

CONDUCTORS WHICH ARE BEING DEMOLISHED, THE CONTRACTOR SHALL REMOVE ALL

CONDUCTORS FROM THE CONDUIT, PROVIDE NEW CONDUCTORS WHICH ARE REPLACEMENTS FOR

THE CONDUCTORS THAT ARE TO REMAIN IN SERVICE AND RE-INSTALL THE NEW CONDUCTORS.

AFTER THE CONDUCTORS ARE PULLED, MEGGER OR HIPOT TEST EACH CONDUCTOR. CONNECT BOTH ENDS OF THE NEW CONDUCTORS AND TEST THE SYSTEM FOR PROPER FUNCTION. DO NOT RE-PULL

USED CONDUCTORS.

8. WHERE EQUIPMENT IS BEING RE-FED FROM A NEW SOURCE, EXISTING CONDUIT MAY BE REUSED

ONLY IF THE CONDUIT AND FITTINGS ARE OF THE TYPE SPECIFIED FOR NEW WORK ON THIS

CONTRACT.

9. IF NOT, THE CONDUIT AND CONDUCTORS SHALL BE REPLACED WITH NEW MATERIAL MEETING THE

SPECIFICATIONS, AT NO ADDITIONAL COST TO THE OWNER.

10. THE OWNER HAS THE RIGHT OF FIRST REFUSAL TO THE EQUIPMENT BEING REMOVED. THE

CONTRACTOR SHALL DELIVER THE EQUIPMENT WHICH THE OWNER WISHES TO KEEP TO A LOCATION DESIGNATED BY THE OWNER. SEE SECTION 26 05 33. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS AND PERMITS REQUIRED TO DISPOSE OFF SITE ALL DEMOLISHED EQUIPMENT REFUSED BY

OWNER.

11. THE CONTRACTOR SHALL NOT MAKE ANY MODIFICATIONS UNTIL THE FOLLOWING HAS BEEN DONE:

A. THE OWNER/CONTRACTOR SHALL WITNESS AND RECORD THE CONDITION OF THE EXISTING

EQUIPMENT, THE CONTRACTOR SHALL NOTE DOWN ANY DEFECTS OR DEFICIENCIES.

B. THE OWNER SHALL OPERATE THE EQUIPMENT TO DEMONSTRATE THE CURRENT CONDITIONS.

THE CONTRACTOR SHALL NOTE DOWN ANY DEFECTS OR DEFICIENCIES.

C. A WRITTEN AND PHOTOGRAPHIC RECORD OF THE OPERATION AND EXISTING CONDITION SHALL BE KEPT IN A THREE RING BINDER AT THE OWNER/CONTRACTOR TRAILER, IN FORM OF PICTURES

AND INFORMATION ON A FORM.

D. A FORM SHALL BE GENERATED BY THE CONTRACTOR TO RECORD THE OBSERVATIONS. BOTH

PARTIES SHALL SIGN ON THE FORM.

E. AFTER THE CHANGES ARE MADE, THE EQUIPMENT SHALL BE INSPECTED AND RE-TESTED TO

DEMONSTRATE THAT IT FUNCTIONS CORRECTLY.

F. NO PORTION OF EXISTING CONDUCTORS SHALL BE SPLICED TO NEW CONDUCTORS FOR RE-USE

WITHOUT SPECIFIC APPROVAL FROM THE OWNER/ENGINEER ON A CASE-BY-CASE BASIS.

12. THE CONTRACTOR SHALL BE RESPONSIBLE TO FURNISH AND INSTALL MATERIAL OR EQUIPMENT

DAMAGED DURING THE COURSE OF HIS WORK.

15. ALL SLOTTED CHANNEL, SLOTTED CHANNEL SUPPORT MATERIAL, WASHERS, SCREWS, NUTS, CONDUIT CLAMPS, ALL THREAD SPRING NUTS AND MISC. MOUNTING HARDWARE SHALL BE 316

STAINLESS STEEL.

16. ALL CONDUITS AND WIRES SHOWN ON THE INTERFACE DIAGRAM SHALL BE INSTALLED BY THE

CONTRACTOR. GROUPING OF CONDUIT AND WIRE MAY BE CHANGED, IF APPROVED BY THE

ENGINEER AND OWNER.

17. ALL CONDULETS SHALL BE ALUMINUM FORM 7 AND SHALL HAVE 316 SS CLAMP COVERS WITH 316

SS CLAMPS AND SCREWS. SCREW DOWN COVERS ARE UNACCEPTABLE.

18. ALL BARE COPPER GROUNDING CONDUCTORS SHALL BE TINNED, ALL GROUND RODS SHALL BE COPPER CLAD STEEL, 3/4" BY 10' LONG. ALL EXPOSED COPPER GROUND CABLES SHALL BE GREEN

INSULATED CONDUCTORS. PROVIDE XHHW-2 INSULATION.

19. WHERE NOTES ON THE DRAWING INDICATE THAT THE CONTRACTOR SHALL FIELD VERIFY, THE INTENT IS FOR THE CONTRACTOR TO INVESTIGATE TO THE EXTENT NECESSARY TO PROVIDE THE

WORK AND MATERIALS PRIOR TO BIDDING AND INCLUDE ALL COSTS IN THE BID PRICE. THE

CONTRACT PRICE SHALL NOT BE INCREASED WHEN THE CONTRACTOR HAS NOT INVESTIGATED PER

THE NOTES DIRECTING THAT TO BE DONE.

20. CONDUITS SHALL NOT BE INSTALLED INTO THE TOP OF ANY NEMA ENCLOSURES RATED FOR DAMP, WET OR HOSE DOWN AREAS MOUNTED IN INDOOR PROCESS AREAS, OUTDOOR AREAS, OR ANY

AREA NOT RATED TO BE DRY (ELECTRICAL ROOMS, CONTROL ROOMS, OR OFFICE AREAS). ANY

ENCLOSURES THAT HAVE BEEN INSTALLED WITH TOP CONDUIT ENTRIES SHALL BE REMOVED AND

REPLACED AT THE CONTRACTOR'S EXPENSE.

21. ALL PORTIONS OF CONDUITS INDICATED FOR REUSE SHALL BE CLEANED BY THE CONTRACTOR

BEFORE REUSE. CLEANING PROCEDURES ARE AS FOLLOWS:

A. PULL A WIRE BRUSH OF THE APPROPRIATE SIZE THROUGH THE CONDUIT.

B. PULL A CONDUIT SWAB OF THE APPROPRIATE SIZE THROUGH THE CONDUIT.

C. PULL A MANDREL OF THE APPROPRIATE SIZE THROUGH THE CONDUIT.

D. THIS PROCEDURE MAY HAVE TO BE REPEATED SEVERAL TIMES UNTIL THE CONDUIT IS CLEAN.

E. LEAVE A PULL STRING IN THE EMPTY CONDUIT AND PLUG BOTH ENDS OF THE CONDUIT AFTER

CLEANING. PLUGS ARE TO BE REMOVED ONLY TO INSTALL NEW CONDUCTORS. THE

CONTRACTOR IS RESPONSIBLE TO REPLACE ANY CONDUIT DAMAGED DURING THESE CLEANING

PROCEDURES AT NO ADDITIONAL COST TO OWNER.

22. THE CONTRACTOR SHALL INSTALL ON ALL CONDUITS PROVIDED OR MODIFIED UNDER THE SCOPE OF THIS PROJECT WITH CONDUIT IDENTIFICATION PLATES. MODIFICATIONS TO CONDUITS INCLUDE CHANGES IN CONDUIT ROUTING AND/OR REPLACING EXISTING OR INSTALLING NEW CONDUCTORS.

THE CONTRACTOR SHALL COORDINATE WITH THE OWNER THE NAMING SYSTEM TO USE IN

IDENTIFYING CONDUITS. WHEN MORE THAN TWO CONDUITS ENTER A JUNCTION BOX, PULL BOX, TERMINAL ENCLOSURE, ETC., ALL CONDUITS SHALL CONTAIN AN IDENTIFICATION PLATE WITH A

UNIQUE IDENTIFICATION.

23. THE CONTRACTOR SHALL PROVIDE NAMEPLATES ON ALL EQUIPMENT WITH DESIGNATIONS AS

REQUIRED BELOW, UNLESS NOTED OTHERWISE BY OWNER.

A. NAMEPLATES SHALL BE ENGRAVED, LAMINATED PLASTIC, NOT LESS THAN 1/16-IN THICK BY 3/4-IN HIGH BY 2 1/2-IN WIDE (MINIMUM) WITH 3/16-IN HIGH BLACK LETTERS ON A WHITE

BACKGROUND.

B. NAMEPLATES SHALL BE 316 SS SCREW MOUNTED TO ALL ENCLOSURES. SCREWS ON NEMA 4

ENCLOSURES SHALL BE SEALED BY UL LISTED METHOD. CONTRACTOR SHALL PROVIDE

SUBMITTAL FOR METHOD OF SEALING SCREWS FOR APPROVAL. EPOXY ADHESIVE OR FOAM

TAPE IS NOT ACCEPTABLE.

THE CONTRACTOR SHALL SUBMIT AS-BUILT DRAWINGS INDICATING ALL EQUIPMENT IDENTIFIED

ABOVE WITH THEIR APPROPRIATE NAMEPLATE DESIGNATION.

24. REFER TO THE CONDUIT TABLE BELOW FOR APPLICABLE TYPE OF CONDUIT PER LOCATION.

25. THE CONTRACTOR SHALL REFER AND PROVIDE EQUIPMENTS AND ACCESSORIES AS PER THE LATEST

WQ STANDARD EQUIPMENT LIST AND WQ ENGINEERING GUIDELINES.

CONDUIT TYPE LOCATION

2. LIQUID TIGHT FLEXIBLE ALUMINUM

CONDUIT

RACEWAY CONNECTION TO VIBRATING EQUIPMENT ONLY, IN ALL

AREAS.

3. GALVANIZED RIGID CONDUIT ALL ABOVE GRADE NON-PROCESS AREAS, EXCEPT FOR CONCRETE

EMBEDDED AND OTHER LOCATIONS DESCRIBED IN THIS TABLE.

1. PVC SCHEDULE 40 CONDUIT UNDERGROUND ENCASED IN RED DYE REINFORCED CONCRETE.

ALL ABOVE GRADE PROCESS AREAS AND ALL EXTERIOR APPLICATION, ALL

ELBOWS UNDERGROUND ENCASED IN RED DYE REINFORCED CONCRETE, ALL

STUB UPS AND USED AS SHOWN ON VARIOUS ELECTRICAL STANDARD

DETAILS.

4. PVC COATED GALVANIZED RIGID CONDUIT

1. ALL EQUIPMENT WIRING, RACEWAYS, ETC. SHALL BE INSTALLED AND GROUNDED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, LOCAL CODES, AND INDUSTRY STANDARDS (UL, NEMA, IEEE, ANSI, ETC.) THE DRAWING NOTES AND DETAILS SHALL BE COMPLIED

WITH IN ADDITION TO THE REQUIREMENTS IN THE SPECIFICATIONS. REFER TO EACH

SPECIFICATION SECTION FOR SPECIFIC REQUIREMENTS.

2. ALL RACEWAY INSTALLATIONS SHALL BE INSTALLED IN A MANNER TO PREVENT CONFLICTS WITH

EQUIPMENT AND STRUCTURAL CONDITIONS. ALL EXPOSED RACEWAY SHALL BE INSTALLED

PARALLEL TO BEAMS, CEILINGS, FLOORS AND WALLS. SEE SECTION 26 05 33 FOR ADDITIONAL

REQUIREMENTS.

3. CONDUITS SHALL BE TERMINATED IN A NEAT MANNER AND STRICTLY IN ACCORDANCE WITH THE SPECIFICATIONS AND DRAWING DETAILS. SEE SECTION 26 05 33 FOR ADDITIONAL REQUIREMENTS.

4. CONDUITS TERMINATED INTO ENCLOSURES SHALL BE PERPENDICULAR TO THE WALLS OF THE ENCLOSURE. THE USE OF SHORT SEAL-TIGHT ELBOW FITTINGS FOR SUCH TERMINATIONS WILL NOT

BE PERMITTED.

5. ALL RACEWAY INSTALLATIONS, CROSSING EXPANSION JOINTS OR TRANSITIONS FROM BELOW

GRADE TO EXPOSED ABOVE GRADE, SHALL HAVE EXPANSION OR EXPANSION/DEFLECTION TYPE

FITTINGS AS SPECIFIED FOR THE APPLICATION. SEE THE DRAWINGS AND SECTION 26 05 33 FOR THE

EXACT TYPE OF FITTING TO BE USED.

6. NO EXPOSED CONDUIT SMALLER THAN 3/4", NOR WIRE SMALLER THAN NO. 12 AWG, SHALL BE

USED UNLESS SPECIFICALLY NOTED.

7. ALL UNDERGROUND SINGLE CONDUIT RUNS, AND DUCTBANKS OF MULTIPLE CONDUIT RUNS,

SHALL BE PVC SCHEDULE 40 CONDUIT, ENCASED IN REINFORCED RED CONCRETE, AND THE

CONCRETE DYED RED BEFORE PLACEMENT, AS SPECIFIED IN SECTION 26 05 33. MINIMUM SIZE

SHALL BE 2 INCH. THE CONTRACTOR SHALL FIELD VERIFY THE ROUTING OF ALL EXISTING

UNDERGROUND CONDUIT AND DUCTBANKS AND SHALL COORDINATE THE ROUTING OF NEW

CONDUIT AND DUCTBANKS TO AVOID INTERFERENCE WITH EXISTING CONDUIT AND DUCTBANKS

AND OTHER UNDERGROUND UTILITIES.

8. FOR ALL JUNCTION BOXES, PULL BOXES AND TERMINATION BOXES IN THE RACEWAY SYSTEM IN NEMA 12 AREAS, BOXES SHALL BE OF ALUMINUM. FOR NEMA 4X AREAS BOXES SHALL BE OF 316 STAINLESS STEEL, UNLESS NOTED OTHERWISE, SEE SECTION 26 05 33 FOR BOX DETAILS AND

SPECIFICATIONS.

9. WHERE RACEWAYS ENTER JUNCTION BOXES OR CONTROL PANELS CONTAINING ELECTRICAL OR INSTRUMENTATION EQUIPMENT, ALL ENTRANCES SHALL BE SEALED WITH WATERTIGHT SEALANT.

REFER TO SECTION 26 05 33 FOR DETAILS.

10. ALL EQUIPMENT AND ELECTRICAL EQUIPMENT ENCLOSURE LOCATIONS, OR TERMINAL BOX

LOCATIONS, ARE APPROXIMATE. THE EXACT LOCATIONS SHALL BE COORDINATED WITH AND

APPROVED BY THE OWNER/ENGINEER, DURING CONSTRUCTION, AT NO ADDITIONAL COST TO THE

OWNER.

11. ALL EQUIPMENT AND ELECTRICAL EQUIPMENT ENCLOSURES DIMENSIONS ARE APPROXIMATE. ALL EQUIPMENT AND ELECTRICAL EQUIPMENT ENCLOSURES OR TERMINAL BOX DIMENSIONS SHALL BE VERIFIED WITH THE EQUIPMENT SUPPLIER. ALLOW FOR LOCATION CHANGES AND INCLUDE IN THE CONTRACT PRICE. THE EXACT LOCATIONS OF ALL ELECTRICAL EQUIPMENT AND ROUTING OF ALL

CABLES AND CONDUITS SHALL BE COORDINATED WITH AND APPROVED BY THE OWNER/ENGINEER

DURING CONSTRUCTION.

12. CORING OF AN EXISTING STRUCTURE SHALL BE COORDINATED WITH AND APPROVED BY THE

OWNER/ENGINEER. CORING THROUGH STRUCTURAL BEAMS IS STRICTLY PROHIBITED, WITHOUT

PRIOR WRITTEN APPROVAL FROM THE OWNER/ENGINEER.

13. PROVIDE CONDUIT SEALS FOR CONDUIT PENETRATIONS. SEE SECTION 26 05 33 FOR DETAILS.

14. THIS IS AN OPERATING FACILITY. THE CONTRACTOR SHALL COORDINATE ALL WORK WITH THE

OWNER. NO SHUTDOWN OF ELECTRICAL OR CONTROL EQUIPMENT WILL NOT BE PERMITTED

WITHOUT A SHUTDOWN REQUEST IN WRITING BEING SUBMITTED AND APPROVED PER

SPECIFICATIONS.

ELECTRICAL GENERAL NOTES

GE

N

ER

AL

N O

TE

S

G-G-03

25. NEW LIGHT FIXTURES SHALL BE IN ACCORDANCE WITH OCWUT "WQ STANDARD EQUIPMENT

LIST, VERSION 6, FOR LED LOW BAY LIGHT: SIGNIFY GARDCO SOFTVIEW LED

(SVPG-A10-750-5RD-SUR-UNV-MG).

ABBREVIATIONS

(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)HVAC SYMBOLS

A/C AIR CONDITIONING

AFF ABOVE FINISHED FLOOR

AI ANALOG INPUT

AO ANALOG OUTPUT

APPROX APPROXIMATELY

ARCH ARCHITECTURE/ARCHITECTURAL

AV ANALOG VALUE

BI BINARY INPUT

BHP BRAKE HORSEPOWER

BO BINARY OUTPUT

BOD BOTTOM OF DUCT

BTUH BRITISH THERMAL UNIT PER HOUR

BV BINARY VALUE

C CELSIUS

CC COOLING COIL

CFM CUBIC FEET PER MINUTE

CD CONDENSATE DRAIN

CONN CONNECTION

dB DECIBELS

DI DIGITAL INPUT

DIA DIAMETER

DB DRY BULB

DDC DIRECT DIGITAL CONTROL

DEG DEGREE

DO DIGITAL OUTPUT

DX DIRECT EXPANSION

DWGS DRAWINGS

ELEC ELECTRIC/ELECTRICAL

EAT ENTERING AIR TEMPERATURE

EWT ENTERING WATER TEMPERATURE

EFF EFFICIENCY

EL ELEVATION

EMCS ENERGY MONITORING AND CONTROL SYSTEM

EXH EXHAUST

F FAHRENHEIT

FLEX FLEXIBLE

FPM FEET PER MINUTE

FT FEET, FOOT

GPM GALLONS PER MINUTE

HC HEATING COIL

HVAC HEATING, VENTILATION AND AIR CONDITIONING

HZ HERTZ

HP HORSEPOWER

HTG HEATING

IN INCHES

KW KILOWATT

LAT LEAVING AIR TEMPERATURE

LWT LEAVING WATER TEMPERATURE

MAX MAXIMUM

MECH MECHANICAL

MCA MINIMUM CIRCUIT AMPACITY

MBH THOUSANDS BTU's PER HOUR

MIN MINIMUM

MOCP MAXIMUM OVERCURRENT PROTECTION

NFPA NATIONAL FIRE PROTECTION ASSOC.

NC NOISE CRITERIA

NOM NOMINAL

NTS NOT TO SCALE

NO NUMBER

N.C. NORMALLY CLOSED

N.O. NORMALLY OPEN

OA OUTSIDE AIR

P/PH PHASE

PLBG PLUMBING

PSI POUNDS PER SQUARE INCH

RE REFER/REFERENCE

RA RETURN AIR

RPM REVOLUTIONS PER MINUTE

SMACNA SHEET METAL AND AIR CONDITIONING

CONTRACTORS NATIONAL ASSOC.

SQ FT SQUARE FEET

SP STATIC PRESSURE

SA SUPPLY AIR

TEMP TEMPERATURE

T-STAT THERMOSTAT

TYP TYPICAL

VAV VARIABLE AIR VOLUME

VFD VARIABLE FREQUENCY DRIVE

VD VOLUME DAMPER

WT WATTS

WTR WATER

WC WATER COLUMN

WG WATER GAUGE

WB WET BULB

DUCTWORK SYMBOLS

DUCTWORK SIZE TRANSITION.

RADIUS DUCTWORK ELBOW

ROUND OR RECTANGULAR

RADIUS DUCTWORK ELBOW

ROUND OR RECTANGULAR

FLEXIBLE DUCT

ROUND DUCTWORK

RETURN/TRANSFER AIR GRILLE

EXHAUST GRILLE

SUPPLY AIR PLENUM SLOT DIFFUSER

SD - SMOKE DAMPER

CD - COMBINATION FIRE/SMOKE DAMPER

RELIEF OR EXHAUST AIR DUCT DOWN

MANUAL VOLUME (BALANCE) DAMPER

90° ELBOW WITH TURNING VANES

RELIEF OR EXHAUST AIR DUCT UP

RETURN AIR DUCT DOWN

FD - FIRE DAMPER

MOTORIZED DAMPER

SUPPLY AIR DUCT UP

SUPPLY AIR DUCT DOWN

FLEXIBLE DUCT CONNECTION

RETURN AIR DUCT UP

TO EQUIPMENT

12/12

12"

FD

M

ROUND DUCT BRANCH TAKE-OFF FROM

RECTANGULAR OR FLAT OVAL MAIN WITH

CONICAL TAP. PROVIDE BALANCE DAMPER

FOR LOW PRESSURE DUCTWORK ONLY

RECTANGULAR DUCTWORK BRANCH TAKE-OFF

W/DAMPER AND 45 DEGREE BRANCH INLET

RECTANGULAR DUCTWORK. SIZE INDICATED IN

INCHES, FIRST NUMBER IS SIDE SHOWN

SUPPLY AIR DIFFUSER - ARROWS INDICATE

PATTERN. NO ARROWS SHOWN EQUALS

4-WAY.

SA

SA

RA

RA

EA

EA

EQUIPMENT DESIGNATIONS

DOAS DEDICATED OUTSIDE AIR UNIT

EF EXHAUST FAN

L LOUVER

SF SUPPLY FAN

GUH GAS-FIRED UNIT HEATER

DE = CIRCULAR EQUIVALENT OF RECTANGULAR DUCT

GENERAL NOTES

IN INCHES

B = LENGTH OF OTHER SIDE OF DUCT IN INCHES

1. THIS PROJECT IS DESIGNED BASED ON THE FOLLOWING CODES:

INTERNATIONAL MECHANICAL CODE 2015, INTERNATIONAL ENERGY

CONSERVATION CODE 2009, ASHRAE 62.1.

2. ALL INFORMATION REQUIRED FOR DESIGN MAY NOT BE COVERED IN

THE DRAWINGS. REFER TO DIVISION 23 TECHNICAL SPECIFICATIONS

AND OTHER RELATED SECTIONS FOR ADDITIONAL INFORMATION.

3. ALL DUCT SIZES SHOWN ON THE DRAWINGS ARE NET INSIDE CLEAR

DIMENSIONS.

4. UTILIZE LONG RADIUS ELBOWS WHERE SPACE PERMITS UNLESS

OTHERWISE NOTED. ALL RECTANGULAR ELBOWS SHALL CONTAIN

TURNING VANES.

5. COORDINATE WITH OTHER UTILITIES TO AVOID INTERFERENCES WHEN

INSTALLING DUCTWORK, PIPING AND EQUIPMENT.

6. FURNISH AND INSTALL ALL EQUIPMENT AS PER MANUFACTURER'S

RECOMMENDATIONS AND INSTRUCTIONS. PROVIDE MODIFICATIONS

AND ACCESSORIES AS REQUIRED AND RECOMMENDED BY THE

MANUFACTURER TO ASSURE PROPER OPERATION OF THE

EQUIPMENT.

7. VERIFY DIMENSIONS, LOCATIONS, ELEVATIONS AND CONFIGURATION

OF ALL ITEMS ASSOCIATED WITH THE INSTALLATION OF DUCTWORK

AND EQUIPMENT.

8. EQUIPMENT, DUCTWORK AND PIPING SHALL NOT BE SUPPORTED OR

SECURED TO OTHER EQUIPMENT, DUCTWORK, PIPING OR OTHER

UTILITIES.

9. PAINT ALL EQUIPMENT VISIBLE THRU AIR DEVICES MATTE BLACK.

10. PROVIDE MANUAL VOLUME DAMPERS IN ALL DUCTWORK AT ALL

DUCT SPLITS, BRANCH RUNOUTS AND DUCT COLLARS FOR REGISTERS.

ALL MANUAL DAMPERS MAY NOT BE SHOWN ON DRAWINGS.

11. ALL DUCTWORK SHALL BE CONSTRUCTED, SEALED AND INSTALLED IN

CONFORMANCE TO SMACNA DUCT CONSTRUCTION STANDARDS.

12. TO RESOLVE FIELD PROBLEMS IN ROUTING DUCTWORK THE

CONTRACTOR SHALL USE THE SAME CIRCULAR EQUIVALENT

DIAMETER TO TRANSFORM DUCT SIZE FROM THAT SPECIFIED ON THE

DRAWINGS.

13. PROVIDE FIRE DAMPERS IN DUCTWORK AT ALL FIRE BARRIER

PENETRATIONS. PROVIDE ACCESS DOORS IN DUCTWORK TO VIEW

AND SERVICE FIRE DAMPERS PER SMACNA AND APPLICABLE LOCAL

CODES.

14. PROVIDE FIRE RESISTANT FLEXIBLE CONNECTION WHENEVER

DUCTWORK IS CONNECTED TO MOTORIZED EQUIPMENT.

15. DUCT MATERIAL SHALL BE ALUMINUM WITH THICKNESS AS PER

SMACNA CONSTRUCTION STANDARDS.

16. PROVIDE OSHA-REQUIRED CLEARANCES AROUND ALL HVAC

EQUIPMENT AND COMPONENTS FOR PERSONNEL ACCESS AND

MAINTENANCE.

17. ALL PIPE HANGERS AND SUPPORTS SHALL COMPLY WITH

MANUFACTURER'S STANDARDIZATION SOCIETY (MSS) STANDARDS.

VERTICAL PIPES MUST BE SUPPORTED AT EACH FLOOR WITH PIPE

CLAMPS.

18. INSULATE BACKS AND PLENUMS OF SUPPLY AIR DEVICES WITH

MINIMUM 1" MINERAL FIBER.

19. ALL AIR MOVING EQUIPMENT CONTAINING PARTICULATE FILTERS

SHALL NOT BE OPERATED WITHOUT PARTICULATE FILTERS IN PLACE.

20. ADD DIELECTRIC CONNECTIONS BETWEEN PIPES OF DIFFERENT

METALS.

21. MAINTAIN A VERTICAL SLOPE OF 1/8" PER FOOT IN THE DIRECTION OF

FLOW FOR ALL HORIZONTAL CONDENSATE PIPING. ROUTE

CONDENSATE DRAIN ALONG WALL TO TERMINATE OPEN-SITE AT MOP

SINK.

22. INSTALL ALL PIPING PARALLEL TO BUILDING LINES UNLESS STATED

OTHERWISE IN DRAWINGS.

A = LENGTH OF ONE SIDE OF DUCT IN INCHES

DE =

1.30 (AB)

(A + B)

0.625

0.250

"X" INDICATES ZONE)

(LOCAL CONTROL

SP

DIFFUSER/GRILLE/REGISTER LABEL:

"A" - TYPE/DESIGNATION

"200" - AIRFLOW (CFM)

THERMOSTAT

H

T

TT

DRAWING NOTE REFERENCE

DIAMETER/PHASE

DUCT SMOKE DETECTOR

P

S

C

MISCELLANEOUS

X

A200

DUCT MOUNTED STATIC

PRESSURE SENSOR

HUMIDITY SENSOR

TEMPERATURE SENSOR

CO2 SENSOR

PRESSURE SENSOR

SENSOR WITH LOCKING

PROTECTIVE GUARD

POINT OF NEW

CONNECTION BETWEEN

NEW AND EXISTING WORK

DOUBLE LINE

EXISTING EQUIPMENT (FANS,

AIR DEVICES, PUMPS, ETC.)

TO BE RELOCATED.

D U

C T

W O

R K

P

IP

IN

G

NEW

DEMOLITION

EXISTING

TO REMAIN

NEW PLANS

PLAN SYMBOLOGY

R

NEW

DEMOLITION

NEW EQUIPMENT

EXISTING

TO REMAIN

SHEET

SEQ.

F

N J

O B

N O

D A

T E

D E

S

IG

N E

D

D R

A W

N

R E

V

IS

E D

C H

E C

K E

D

F

IL

E N

A M

E V

E R

IF

Y

S C

A

LE

B a r is o n e i n ch o n o ri g in a l d ra w in g

I f n o t o n e i n ch s h e e t, a d ju st s ca le

Plot Date:

N W th

S tr e e t, S u it e

O k la h o m a C it y

O

K

P h o n e

(4

-7

W e b w w w .f re e se .c o m

C e rt if ic a te o f A u th o ri za ti o n

C

A

E xp ir a ti o n D a te

/3

/2

C

IT

Y O

F O

K

LA

H O

M A

C

IT

Y

W T

-0

D R

A P

E R

W A

T E

R T

R E

A T

M E

N T

P

LA

N T

F

IL

T E

R P

IP

E

G A

LL

E

R Y

I M

P R

O V

E M

E N

T S

C O

C

S E

P

9/4/2025 3:50:54 PM

ISSUE FOR BID

H V

A C

N O

T E

S

S Y

M B

O

LS

A

B B

R E

V

IA

T

IO

N S

G-G-08

D C

A

D C

A

W A

Y

H V

A C

-C O

C

-F

IL

R

.R V

T

H V

A C

N O

IS

S U

E B

Y D

A T

E

/0

4/

FILTER BUILDING PIPE GALLERY

PIPE COATINGS (TYP)

NOT TO SCALE

FILTER 1 FILTER 2 FILTER 3 FILTER 4 FILTER 5 FILTER 6

DI AND CI WATER PIPING TO BE

COATED WITH SYSTEM NO. 8 PER

SECTION 09 96 00.0

AIR SUPPLY PIPING TO BE

COATED WITH SYSTEM NO. 8 PER

SECTION 09 96 00.0.

FILTER BUILDING CIVIL NOTES:

1. CONTRACTOR TO COORDINATE WITH OWNER'S PROJECT TEAM TO SCHEDULE ALL

OUTAGES OR IMPACTS TO FILTER OPERATIONS REQUIRED TO COMPLETE COATING

AND CONSTRUCTION ACTIVITIES IN ACCORDANCE WITH SPECIFICATION 01 35 00.

2. NEW D.I. PIPE AND FITTINGS SHALL BE COATED IN ACCORDANCE WITH SPECIFICATION

09 96 00.01.

3. CONTRACTOR SHALL REMOVE AND REPLACE ALL EXISTING COATINGS FROM THE DI

AND CI WATER AND AIR PIPING WITHIN THE PIPE GALLERY, SEE DETAIL THIS PAGE.

4. EXISTING COATINGS CONTAIN LEAD-BASED PAINTS. REMOVE ALL COATINGS FROM

EXISTING D.I. AND C.I. PIPES LOCATED IN THE PIPE GALLERY, SHOWN IN DETAIL 2, IN

ACCORDANCE WITH SECTION 02 83 01. NEW COATINGS SHALL BE INSTALLED IN

ACCORDANCE WITH SPECIFICATION 09 96 00.01.

5. CONTRACTOR TO PROTECT EXISTING VALVES, VALVE ACTUATORS, SAMPLE PORTS,

MISC. SMALL DIAMETER PIPING, ELECTRICAL CONDUIT, ANALYZERS, AIR SCRUBBER

EQUIPMENT, EFFLUENT SEAL BOXES, AND ALL OTHER SURFACES NOT INTENDED TO BE

COATED DURING CONSTRUCTION.

6. BACKGROUND IMAGES ARE SHOWN FROM RECENT PROJECT RECORD DRAWINGS AND

ARE FOR GRAPHICAL REPRESENTATION ONLY. CONTRACTOR TO VERIFY EXACT

LOCATION AND ORIENTATION OF PROPOSED WORK PRIOR TO ORDERING OF

MATERIALS AND INSTALLATION.

7. CONCRETE PIPE SUPPORTS ON FILTERS #5 AND #6 HAVE BEEN DAMAGED AND MUST

BE REPLACED.

SHEET

SEQ.

th is sh ee t, ad ju st sc al e.

dr aw in g.

If n ot o ne in ch o n

Ba r i s o ne in ch o n or ig

E N

O

. VE

RI

FY

S

CA

LE

DA

TE

BY

F&

N

JO

B N

O

FI

LE

N

AM

E

CH

EC

KE

D

RE

VI

SE

D

DR

AW

N

DE

SI

GN

ED

DA

TE

Plot Date: 9/3/2025 4:48 PM Plot By: 03761 Filename: N:\WTU\Drawings\WT0295\CV-ALL-DETL-PIPE-IMP.dwg

CV

-A

LL

-D

ET

L-

PI

PE

-IM

P.

dw g

La st

S av ed : 9

/3 /2

4:

d

By : 0

Fi le na m e:

N

W

TU

\D ra w in gs

\W T0

5\

CV

-A

LL

-D

ET

L-

PI

PE

-IM

P.

dw g

AC

AD

R el

: 2 4.

2s (L

M S

Te ch

ISSUE FOR BID

CI

TY

O F

O

KL

AH

O

M A

CI

TY

W T-

D

RA

PE

R

W

AT

ER

T

RE

AT

M

EN

T

PL

AN

T

FI

LT

ER

P

IP

E

GA

LL

ER

Y

IM

PR

O

VE

M

EN

TS

CO

C2

SE

P

N W th S t., S ui te

O kl ah om a Ci ty , O

K

Ph on e

5)

-7

W eb w w w .fr ee se

.c om

Ce rt ifi ca te o f A ut ho riz at io n:

C

A#

Ex pi ra tio n

Da te

: 0 6/

/2

TREATMENT TRAIN 1 TREATMENT TRAIN 2 TREATMENT TRAIN 3

FILTERS 1-6 FILTERS 7-12 FILTERS 13-18

LOCATION OF CONCRETE FLUME

RE: FB-C-03

SITE PLAN OF PRIMARY PLANT AREA

NOT TO SCALE

NORTH

FILTER BUILDING REPAIR AND REPLACEMENT SCHEDULE

FILTER #

PIPE

REPLACEMENT/SIZE

DRESSER COUPLING

REPLACEMENT

PIPE HANGER

REPAIR/REPLACEMENT

1 Y/16" Y N 2 N Y N 3 Y/16" Y N 4 Y/16" Y N 5 Y/16" Y N 6 N Y N 7 Y/16" Y Y 8 N Y Y 9 N Y Y

10 N Y Y 11 N Y Y 12 N Y N 13 N Y N 14 N Y Y 15 N Y Y 16 N Y Y 17 N Y Y 18 N Y N

CONCRETE

FLUME N N Y

O

KL

AH

O

M A

N O

DA

TE

SI

GN

ED

, S

EA

LE

D

AN

D

DA

TE

D

BY

TH

IS

D O

CU

M

EN

T

W

AS

O

RI

GI

N

AL

LY

TH

E

SE

AL

ED

, S

IG

N

ED

A

N D

DA

TE

D

DO

CU

M

EN

TS

AR

E

M

AI

N

TA

IN

ED

IN

T

HE

O

FF

IC

E O

F

FR

EE

SE

A N

D N

IC

HO

LS

A

N D

M

AY

B E

RE

VI

EW

ED

U

PO

N R

EQ

U

ES

T.

AU

TH

O

RI

ZE

D

BY

9/ 3/

M

EA

GA

N G

. B

RO

W N

P .E

CI

VI

L

FI

LT

ER

B

U

IL

DI

N

G

PI

PE

G

AL

LE

RY

DE

TA

IL

S I

FB-C-01

SD

M M

M M

GB

Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

/REPLACEMENT

09/05/2025

N W th

S tr e e t, S u it e

O k la h o m a C it y

O

K

P h o n e

(4

-7

W e b w w w .f re e se .c o m

C e rt if ic a te o f A u th o ri za ti o n

C

A

E xp ir a ti o n D a te

/3

/2

CONCRETE PIPE SUPPORT

CRADLE DETAIL

NOT TO SCALE

2" C/

C

#4 T

IE

S

3"CLR

(TYP VA

RI

ES

#4 @ 12"C/C MAX

PIPE OD + =1'-2"

EXIST SLAB

3"

#4 BARS, EF

8"

3"

CL

R (T

YP

ADD'L #4 DIAGONAL BARS, EF

8"

3"

8"

#4 TIES @ 12"C/C (MAX)

3" C

LR

#4 DOWELS INTO EXISTING SLAB @ 12" C/C

SPACING, EF, MIN EMBD DEPTH OF 5"

(TYP), HILTI HIT-RE 500 V3 +REBAR OR

APPROVED EQUAL

3" C

LR

EXIST SLAB

SEE NOTE 1SEE NOTE 1

DRAIN PIPE REPLACEMENT

NOT TO SCALE

24" BACKWASH WATER LINE

24"X24" TEE

TO REMAIN, TYP.

24"X20" 90° BEND

TO REMAIN, TYP.

18"X16" DRAIN TEE

TO REMAIN, TYP.

REPLACE 16" C.I.

DRAIN PIPE, TYP.

(SEE NOTE 1)

16" 90° DRAIN BEND

TO REMAIN, TYP.

18" BFV

TO REMAIN

DETAIL NOT USED

NOT TO SCALE

NOTES:

1. CONTRACTOR TO REMOVE AND /OR RELOCATE CONCRETE PIPE SUPPORTS AS NEEDED

TO ACCOMMODATE CONSTRUCTION AND RESTORE SUPPORT EXHIBITING EXISTING

DAMAGE.

2. CONTRACTOR TO ENSURE MINIMUM CLEARANCE ON CONCRETE SUPPORTS TO ALLOW

FOR REMOVAL OF BOLTS IN PIPE FLANGE PER SCHEDULE.

3. REMOVE 16" DRAIN PIPE AND REPLACE WITH NEW 16" D.I. PIPE (5 FT SECTION) PER

SCHEDULE DETAIL 1 OF THIS SHEET. PROTECT EXISTING CONCRETE SLAB. PLACE

NON-SHRINK GROUT AROUND PIPE PENETRATION. SEE DRAIN PIPE REPLACEMENT

SCHEDULE FOR SECTIONS TO BE REPLACED.

4. FITTINGS SHALL HAVE NUTS AND BOLTS IN ACCORDANCE WITH SECTION 39 OF THE

SPECIAL PROVISIONS. EXISTING NUTS AND BOLTS MAY BE REUSED IF THEY ARE IN

ACCEPTABLE CONDITION.

5. CONTRACTOR SHALL TEMPORARILY REMOVE ANY ELECTRICAL OR MECHANICAL

EQUIPMENT, CONDUIT, OR CABLES ATTACHED TO THE EXISTING CONCRETE PIPE

SUPPORTS AND REINSTALL ON NEW PIPE SUPPORT USING 316 SS HARDWARE.

6. BACKGROUND IMAGES ARE SHOWN FROM RECENT PROJECT RECORD DRAWINGS AND

ARE FOR GRAPHICAL REPRESENTATION ONLY. CONTRACTOR TO VERIFY EXACT

LOCATION AND ORIENTATION OF PROPOSED WORK.

SHEET

SEQ.

th is sh ee t, ad ju st sc al e.

dr aw in g.

If n ot o ne in ch o n

Ba r i s o ne in ch o n or ig

E N

O

. VE

RI

FY

S

CA

LE

DA

TE

BY

F&

N

JO

B N

O

FI

LE

N

AM

E

CH

EC

KE

D

RE

VI

SE

D

DR

AW

N

DE

SI

GN

ED

DA

TE

Plot Date: 9/3/2025 4:48 PM Plot By: 03761 Filename: N:\WTU\Drawings\WT0295\CV-ALL-DETL-PIPE-IMP.dwg

CV

-A

LL

-D

ET

L-

PI

PE

-IM

P.

dw g

La st

S av ed : 9

/3 /2

4:

d

By : 0

Fi le na m e:

N

W

TU

\D ra w in gs

\W T0

5\

CV

-A

LL

-D

ET

L-

PI

PE

-IM

P.

dw g

AC

AD

R el

: 2 4.

2s (L

M S

Te ch

ISSUE FOR BID

CI

TY

O F

O

KL

AH

O

M A

CI

TY

W T-

D

RA

PE

R

W

AT

ER

T

RE

AT

M

EN

T

PL

AN

T

FI

LT

ER

P

IP

E

GA

LL

ER

Y

IM

PR

O

VE

M

EN

TS

CO

C2

SE

P

N W th S t., S ui te

O kl ah om a Ci ty , O

K

Ph on e

5)

-7

W eb w w w .fr ee se

.c om

Ce rt ifi ca te o f A ut ho riz at io n:

C

A#

Ex pi ra tio n

Da te

: 0 6/

/2

O

KL

AH

O

M A

N O

DA

TE

SI

GN

ED

, S

EA

LE

D

AN

D

DA

TE

D

BY

TH

IS

D O

CU

M

EN

T

W

AS

O

RI

GI

N

AL

LY

TH

E

SE

AL

ED

, S

IG

N

ED

A

N D

DA

TE

D

DO

CU

M

EN

TS

AR

E

M

AI

N

TA

IN

ED

IN

T

HE

O

FF

IC

E O

F

FR

EE

SE

A N

D N

IC

HO

LS

A

N D

M

AY

B E

RE

VI

EW

ED

U

PO

N R

EQ

U

ES

T.

AU

TH

O

RI

ZE

D

BY

9/ 3/

M

EA

GA

N G

. B

RO

W N

P .E

CI

VI

L

FI

LT

ER

B

U

IL

DI

N

G

PI

PE

G

AL

LE

RY

DE

TA

IL

S

II

FB-C-02

SD

M M

M M

GB

SCOPE OF WORK TO BE

PERFORMED BY OTHERS

ALL NEW NUTS AND BOLTS SHALL BE 316 SS.

09/05/2025

N W th

S tr e e t, S u it e

O k la h o m a C it y

O

K

P h o n e

(4

-7

W e b w w w .f re e se .c o m

C e rt if ic a te o f A u th o ri za ti o n

C

A

E xp ir a ti o n D a te

/3

/2

36" DRESSER COUPLING

AND HANGER REPLACEMENT (TYP)

NOT TO SCALE

REMOVE AND REPLACE

36" DRESSER COUPLING

REMOVE AND REPLACE 2 X 36" PIPE

HANGERS PER SCHEDULE. (TYP)

REPAIR AND RECOAT

SUPPORTS WITH SYSTEM

NO. 8 PER SECTION 09 96

00.01

CONCRETE FLUME

HANGER REPAIR

NOT TO SCALE

REPAIR AND RECOAT SUPPORTS

WITH SYSTEM NO. 8 PER

SECTION 09 96 00.01

REPAIR AND RECOAT

SUPPORTS WITH SYSTEM NO.

8 PER SECTION 09 96 00.01

NOTES FOR DETAIL 2:

FLUME SUPPORT REPAIRS:

1. CONTRACTOR TO REMOVE EXISTING COATING, PROVIDE SURFACE REPAIR AS NEEDED,

AND RECOAT EXISTING STEEL SUPPORTS FOR CONCRETE FLUME.

2. CONCRETE FLUME IS LOCATED DIRECTLY WEST OF FILTER #7.

3. CONTRACTOR TO PROVIDE TEMPORARY SUPPORTS AS NEEDED DURING

CONSTRUCTION.

4. CONTRACTOR TO REPLACE DRESSER COUPLINGS AND HANGERS PER SECTION 33 01 03

PER SCHEDULE ON SHEET FB-C-01.

5. BACKGROUND IMAGES ARE SHOWN FROM RECENT PROJECT RECORD DRAWINGS

AND ARE FOR GRAPHICAL REPRESENTATION ONLY. CONTRACTOR TO VERIFY EXACT

LOCATION AND ORIENTATION OF PROPOSED WORK.

SHEET

SEQ.

th is sh ee t, ad ju st sc al e.

dr aw in g.

If n ot o ne in ch o n

Ba r i s o ne in ch o n or ig

E N

O

. VE

RI

FY

S

CA

LE

DA

TE

BY

F&

N

JO

B N

O

FI

LE

N

AM

E

CH

EC

KE

D

RE

VI

SE

D

DR

AW

N

DE

SI

GN

ED

DA

TE

Plot Date: 9/3/2025 4:48 PM Plot By: 03761 Filename: N:\WTU\Drawings\WT0295\CV-ALL-DETL-PIPE-IMP.dwg

CV

-A

LL

-D

ET

L-

PI

PE

-IM

P.

dw g

La st

S av ed : 9

/3 /2

4:

d

By : 0

Fi le na m e:

N

W

TU

\D ra w in gs

\W T0

5\

CV

-A

LL

-D

ET

L-

PI

PE

-IM

P.

dw g

AC

AD

R el

: 2 4.

2s (L

M S

Te ch

ISSUE FOR BID

CI

TY

O F

O

KL

AH

O

M A

CI

TY

W T-

D

RA

PE

R

W

AT

ER

T

RE

AT

M

EN

T

PL

AN

T

FI

LT

ER

P

IP

E

GA

LL

ER

Y

IM

PR

O

VE

M

EN

TS

CO

C2

SE

P

N W th S t., S ui te

O kl ah om a Ci ty , O

K

Ph on e

5)

-7

W eb w w w .fr ee se

.c om

Ce rt ifi ca te o f A ut ho riz at io n:

C

A#

Ex pi ra tio n

Da te

: 0 6/

/2

O

KL

AH

O

M A

N O

DA

TE

SI

GN

ED

, S

EA

LE

D

AN

D

DA

TE

D

BY

TH

IS

D O

CU

M

EN

T

W

AS

O

RI

GI

N

AL

LY

TH

E

SE

AL

ED

, S

IG

N

ED

A

N D

DA

TE

D

DO

CU

M

EN

TS

AR

E

M

AI

N

TA

IN

ED

IN

T

HE

O

FF

IC

E O

F

FR

EE

SE

A N

D N

IC

HO

LS

A

N D

M

AY

B E

RE

VI

EW

ED

U

PO

N R

EQ

U

ES

T.

AU

TH

O

RI

ZE

D

BY

9/ 3/

M

EA

GA

N G

. B

RO

W N

P .E

CI

VI

L

FI

LT

ER

B

U

IL

DI

N

G

PI

PE

G

AL

LE

RY

DE

TA

IL

S

III

FB-C-03

SD

M M

M M

GB

BACKGROUND IMAGES ARE SHOWN FROM RECENT PROJECT RECORD DRAWINGS

AND ARE FOR GRAPHICAL REPRESENTATION ONLY. CONTRACTOR TO VERIFY EXACT

LOCATION AND ORIENTATION OF PROPOSED WORK.

09/05/2025

N W th

S tr e e t, S u it e

O k la h o m a C it y

O

K

P h o n e

(4

-7

W e b w w w .f re e se .c o m

C e rt if ic a te o f A u th o ri za ti o n

C

A

E xp ir a ti o n D a te

/3

/2

5. CONTRACTOR REPLACE STEEL SUPPORTS IF CORROSION IS EXCESSIVE TO THE EXTENT

REPAIRS ARE NOT POSSIBLE AS DETERMINED BY OWNER AND ENGINEER.

TT

T

T

12 2

GENERAL NOTES

1 REFER TO G-G-08 HVAC FOR LEGEND, GENERAL NOTES AND ABBREVIATIONS.

2 REFER TO G-G-09 FOR PLUMBING LEGEND, GENERAL NOTES AND SCHEDULES.

3 REFER TO DIVISION 23 FOR TECHNICAL SPECIFICATIONS.

4 REFER TO ELECTRICAL DRAWINGS FOR POWER ROUTING/CONNECTION TO MECHANICAL EQUIPMENT.

5 ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL CONDUIT FOR ALL CONTROL WIRING. COORDINATE WITH

CONTROLS/MECHANICAL CONTRACTOR FOR EQUIPMENT AND DEVICE PLACEMENT.

6 THE CONTRACTORS ARE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES AND FINISHES NOT BEING REPLACED OR

REMOVED.

7 CONTRACTORS TO FIELD VERIFY EXISTING EQUIPMENT AND INSTALLATION OF NEW EQUIPMENT, CONTROLS, WIRING, AND SUPPORTS.

AVOID CONFLICT WITH EXISTING TRADES.

8 INSTALL ALL EQUIPMENT AND ACCESSORIES PER MANUFACTURER REQUIREMENTS.

EF-1

SF-1

EF-2

GUH-1

1 GUH-5

1"ø

736' - 8"

G G

G G 1/2"ø

3/4"ø12

(TYP OF 18)

14 14

1 1/4"ø

GUH-3

GUH-4

10 10

EXISTING

WQ PANEL

(TYP)

GUH-2

11 11 1 1/4"ø

/2

"ø

1/2"ø1/2"ø

3/4"ø

1/2"ø

1"ø

GG G

NORTH

SHEET

SEQ.

F

N J

O B

N O

D A

T E

D E

S

IG

N E

D

D R

A W

N

R E

V

IS

E D

C H

E C

K E

D

F

IL

E N

A M

E V

E R

IF

Y

S C

A

LE

B a r is o n e i n ch o n o ri g in a l d ra w in g

I f n o t o n e i n ch s h e e t, a d ju st s ca le

Plot Date:

N W th

S tr e e t, S u it e

O k la h o m a C it y

O

K

P h o n e

(4

-7

W e b w w w .f re e se .c o m

C e rt if ic a te o f A u th o ri za ti o n

C

A

E xp ir a ti o n D a te

/3

/2

C

IT

Y O

F O

K

LA

H O

M A

C

IT

Y

W T

-0

D R

A P

E R

W A

T E

R T

R E

A T

M E

N T

P

LA

N T

F

IL

T E

R P

IP

E

G A

LL

E

R Y

I M

P R

O V

E M

E N

T S

C O

C

S E

P

9/4/2025 3:50:55 PM

ISSUE FOR BID

F

LO

O R

P

LA

N

FB-H-01

D C

A

D C

A

W A

Y

H V

A C

-C O

C

-F

IL

R

.R V

T

H V

A C

F

IL

T E

R B

U

IL

D

IN

G P

IP

E

G A

LL

E

R Y

1" = 30'-0"

1 PIPING GALLERY DEMOLITION PLAN

1" = 30'-0"

2 PIPING GALLERY FLOOR PLAN

1 EXISTING FAN TO REMAIN, MECHANICAL CONTRACTOR TO REPROGRAM AND REBALANCE THE FAN TO EXHAUST 9,000 CFM. FAN SHALL BE CONTROLLED BY LOCAL SWITCH.

2 DEMOLISH EXISTING FAN AND ASSOCIATED CONTROLS, ACCESSORIES, AND SUPPORTS.

3 PROVIDE NEW SUPPLY FAN (SF-1) WITH MOTORIZED DAMPER. USE EXISTING DECK OPENING, REPAIR AS NECESSARY. INTERLOCK DAMPER WITH FAN. FAN SHALL BE CONTROLLED BY LOCAL

SWITCH.

4 PROVIDE NEW EXHAUST FAN (EF-1) WITH MOTORIZED DAMPER. USE EXISTING DECK OPENING, REPAIR AS NECESSARY. INTERLOCK DAMPER WITH FAN. FAN SHALL BE CONTROLLED BY LOCAL

SWITCH.

5 PROVIDE MANUAL SWITCH FOR FAN OPERATION IN PIPING GALLERY. INSTALL BOTTOM OF SWITCH AT 48" AFF.

6 PROVIDE GAS-FIRED UNIT HEATER. INSTALL BOTTOM OF HEATER 12'-0" AFF. PROVIDE AND ROUTE TYPE B VENT UP THROUGH SLAB/CEILING AND ROOF AND TERMINATE ON ROOF, PER

MANUFACTURER REQUIREMENTS. PLACEMENT IS GENERAL, MECHANICAL CONTRACTOR TO FIELD VERIFY AND COORDINATE EXACT LOCATION AND AVOID CONFLICTS.

7 PROVIDE GAS-FIRED UNIT HEATER. INSTALL BOTTOM OF HEATER 10'-0" AFF. PROVIDE AND ROUTE TYPE B VENT UP THROUGH SLAB AND TERMINATE ABOVE GRADE, PER MANUFACTURER

REQUIREMENTS. PLACEMENT IS GENERAL, MECHANICAL CONTRACTOR TO FIELD VERIFY AND COORDINATE EXACT LOCATION AND AVOID CONFLICTS.

8 PROVIDE GAS-FIRED UNIT HEATER. INSTALL BOTTOM OF HEATER 10'-0" AFF. PROVIDE AND ROUTE TYPE B VENT UP THROUGH SLAB AND TERMINATE ABOVE GRADE, PER MANUFACTURER

REQUIREMENTS. VENT SHALL TERMINATE A MINIMUM OF 3'-0" ABOVE SF-1 INLET. PLACEMENT IS GENERAL, MECHANICAL CONTRACTOR TO FIELD VERIFY AND COORDINATE EXACT LOCATION

AND AVOID CONFLICTS.

9 ROUTE UNDERGROUND TO EXISTING GAS METER AT ADMIN BUILDING. ESTIMATED GAS CAPACITY IS 315 CFH AND PRESSURE IS 14" WC. CONFIRM WITH LOCAL NATURAL GAS PROIVDER THAT

GAS PRESSURE AND CAPACITY CAN ACCOMODATE THE NEW DEMAND.

10 PROVIDE GAS PIPING APPROXIMATELY 14' - 0" AFF. ROUTE AROUND ANY OBSTRUCTIONS UNLESS INDICATED ON PLANS OTHERWISE. PROVIDE SHUT-OFF VALVE, DIRT-LEG, AND FLEX

CONNECTION TO GAS HEATERS PER MANUFACTURER RECOMMENDATIONS.

11 PROVIDE THERMOSTAT FOR GAS-FIRED UNIT HEATER. INSTALL BOTTOM OF THERMOSTAT 4'-0" AFF.

12 EXISTING 36" CI INFLUENT PIPE (TYP). CENTERLINE APPROX. 11'-0" AFF. FIELD VERIFY FOR EXACT LOCATION.

13 EXISTING 24" BACK WASH WATER PIPE. CENTERLINE APPROX. 15'-6" AFF. FIELD VERIFY FOR EXACT LOCATION.

14 EXISTING 12" SURFACE WASH PIPE. CENTERLINE APPROX. 16'-0" AFF. FIELD VERIFY FOR EXACT LOCATION.

NOTES BY SYMBOL " "

0 30' 60'

SCALE IN FEET

10' 20'

N O

IS

S U

E B

Y D

A T

E

/0

4/

AIR FLOW

ACCESS

PANEL

HEATER

RUBBER-IN SHEAR

VIBRATION

ISOLATORS

CONCRETE SLAB OR DECK

MANUAL SHUT-OFF

VALVE

DRIP LEG

GAS SUPPLY PIPING.

SECURE PIPE TO

STRUCTURE

APPROVED FLEXIBLE

CONNECTOR

NOTES:

1. CONTRACTOR SHALL ABIDE BY ALL MANUFACTURER'S UNIT HEATER, GAS

PIPING AND VENT SYSTEM INSTALLATION REQUIREMENTS.

TEE WITH DRIP LEG

AND CLEANOUT CAP

12" MINIMUM

REFER TO DRAWINGS FOR

TERMINATION LOCATIONS.

INSTALL BOTTOM OF

TERMINAL CAP A MINIMUM

OF 48" ABOVE SLAB/ROOF

UNLESS INDICATED

OTHERWISE

SLEEVE

THREADED ROD

FLASHING COLLAR

COUNTER FLASHING

LISTED TERMINAL CAP

M

IN

TYPE "B" VENT

EXISTING CONCRETE SLAB

EXISTING BUILDING

OPENING. FIELD VERIFY

DIMENSIONS AND MODIFY

AS NECESSARY

M

TALL BASE WITH

FACTORY-FURNISHED

MOTORIZED DAMPER

BIRD SCREEN

REMOVEABLE

(ACCESSIBLE)

FAN HOOD

ACCESS DOOR

WASHABLE ALUMINUM FILTERS AS

REQUIRED (REFER TO FAN

SCHEDULE)

NEW CONCRETE

CURB

PREFABRICATED

ROOF CURB

1/2" THICK CLOSED-CELL

NEOPRENE SEAL

3/8" HILTI KWIK BOLT 3 EXPANSION ANCHORS

OR EQUAL. MINIMUM 2 1/2" EMBEDMENT.

INSTALL MANUFACTURER RECOMMENDED

QUANITY OF FASTENERS ON FLANGE CORNERS

AND SIDES

MOUNTING FLANGE

M

IN

BELT OR DIRECT DRIVE FAN

(REFER TO FAN SCHEDULE)

SUPPLY OR

EXHAUST

(REFER TO FAN

SCHEDULE)

M

IN

IN

(N

T E

DETAIL NOTES:

1. COORDINATE REQUIRED CURB HEIGHT WITH EQUIPMENT

MANUFACTURER PRIOR TO FABRICATION OR CONSTRUCTION.

4 1/2" MIN

4 1/2" MIN

C

LR

E M

B E

D

#4 ADHESIVE

ANCHOR @ 12"C/C

AROUND PERIMETER

OF EXIST OPNG W/

3" EMBED

SHEET

SEQ.

F

N J

O B

N O

D A

T E

D E

S

IG

N E

D

D R

A W

N

R E

V

IS

E D

C H

E C

K E

D

F

IL

E N

A M

E V

E R

IF

Y

S C

A

LE

B a r is o n e i n ch o n o ri g in a l d ra w in g

I f n o t o n e i n ch s h e e t, a d ju st s ca le

Plot Date:

N W th

S tr e e t, S u it e

O k la h o m a C it y

O

K

P h o n e

(4

-7

W e b w w w .f re e se .c o m

C e rt if ic a te o f A u th o ri za ti o n

C

A

E xp ir a ti o n D a te

/3

/2

C

IT

Y O

F O

K

LA

H O

M A

C

IT

Y

W T

-0

D R

A P

E R

W A

T E

R T

R E

A T

M E

N T

P

LA

N T

F

IL

T E

R P

IP

E

G A

LL

E

R Y

I M

P R

O V

E M

E N

T S

C O

C

S E

P

9/4/2025 3:50:56 PM

ISSUE FOR BID

D E

T A

IL

S

E

Q U

IP

M

E N

T S

C H

E D

U

LE

S

FB-H-02

D C

A

D C

A

W A

Y

H V

A C

-C O

C

-F

IL

R

.R V

T

H V

A C

F

IL

T E

R B

U

IL

D

IN

G P

IP

E

G A

LL

E

R Y

REMARKS:

1. PROVIDE WITH ALL ACCESSORIES FOR ROOF/SLAB MOUNTING. FAN SHALL HAVE A TALL BASE WITH DAMPER ACCESS AND ROOF CURB.

2. PROVIDE WITH ALUMINUM BIRD SCREEN.

3. PROVIDE WITH WASHABLE ALUMINUM MESH FILTERS.

4. PROVIDE WITH FACTORY-FURNISHED NEMA 4X DISCONNECT.

5. PROVIDE WITH SPEED CONTROLLER.

6. PROVIDE WITH HI-PRO POLYESTER (OR APPROVED EQUAL) COATING.

7. PROVIDE WITH MOTORIZED DAMPER.

8. PROVIDE WITH FACTORY SINGLE POINT WIRING AND FACTORY HARD-WIRED STEP-DOWN TRANSFORMER FOR 120 VAC/1 PH DAMPER ACTUATOR.

FAN SCHEDULE

MARK SERVICE TYPE DRIVE FEI CFM

ESP (IN

W.G)

MAX.

SONES HP FAN RPM

UNIT ELECTRICAL WEIGHT

(LBS) MANUFACTURER/MODEL NOTESVOLTAGE PHASE MCA MOCP

EF-1 EXHAUST ROOF MOUNTED, PROPELLER HOODED BELT 1.60 9,000 0.29 24 1 1/2 891 460 3 3.0 15 700 GREENHECK/RBCE-3H36 1,2,4,5,6,7,8

SF-1 SUPPLY ROOF MOUNTED, PROPELLER HOODED BELT 1.15 12,000 0.27 35 3 1016 460 3 4.8 15 700 GREENHECK/RBCF-3H36 1,2,3,4,5,6,7,8

GAS-FIRED UNIT HEATER SCHEDULE

MARK TYPE

INPUT

(MBH)

OUTPUT

(MBH)

AIRFLOW

(CFM)

THROW

(FT)

UNIT ELECTRICAL WEIGHT

(LBS) MANUFACTURER/MODEL NOTESHP VOLTAGE PHASE

GUH-1 NATURAL GAS 60.0 49.8 769 39 0.06 115 1 71 REZNOR/UDXC-60 1,2,3,4,5,6,7

GUH-2 NATURAL GAS 75.0 62.2 961 52 0.06 115 1 76 REZNOR/UDXC-75 1,2,3,4,5,6,7

GUH-3 NATURAL GAS 60.0 49.8 769 39 0.06 115 1 71 REZNOR/UDXC-60 1,2,3,4,5,6,7

GUH-4 NATURAL GAS 60.0 49.8 769 39 0.06 115 1 71 REZNOR/UDXC-60 1,2,3,4,5,6,7

GUH-5 NATURAL GAS 60.0 49.8 769 39 0.06 115 1 71 REZNOR/UDXC-60 1,2,3,4,5,6,7

REMARKS:

1. REFER TO ELECTRICAL DRAWINGS FOR UNIT DISCONNECTS.

2. PROVIDE APPROPRIATE ACCESSORIES TO SUPPORT HEATER FROM CEILING.

3. PROVIDE WITH VIBRATION ISOLATION KIT.

4. PROVIDE WITH VERTICAL AND HORIZONTAL DEFLECTOR BLADES.

5. UNIT SHALL TAKE COMBUSTION AIR FROM SPACE DIRECTLY (POWER-VENTED).

6. PROVIDE REMOTE NEMA 4X 24VAC THERMOSTAT, SETPOINT 55°F (ADJ.).

7. MAINTAIN MINIMUM 18" SERVICE CLEARANCE ON ALL SIDES AND COMBUSTIBLE CLEARANCE AS SPECIFIED BY MANUFACTURER.

NOT TO SCALE

1 GAS-FIRED UNIT HEATER DETAIL

NOT TO SCALE

2 HOODED AXIAL SUPPLY/EXHAUST FAN DETAIL

N O

IS

S U

E B

Y D

A T

E

/0

4/

NOTE:

X

X

CLASS I, DIV.1,

GROUP D

THREE 4-INCH CONDUITS

INDICATES THAT ALL ELECTRICAL EQUIPMENT AND

MATERIALS INSTALLED WITHIN THE ROOM OR AREA

IN WHICH THIS NOTATION APPEARS SHALL BE OF

NEMA 12 CONSTRUCTION UNLESS OTHERWISE NOTED

INDICATES THAT ALL ELECTRICAL EQUIPMENT AND

MATERIALS INSTALLED WITHIN THE ROOM OR AREA

IN WHICH THIS NOTATION APPEARS SHALL BE OF

NEMA 4X CONSTRUCTION UNLESS OTHERWISE NOTED

DENOTES A QUANTITY OF TWO INSTRUMENT CABLES.

EACH CONSISTS OF TWO NO.16 AWG CONDUCTORS

CABLE TAG FOUR #14 CONTROL OR POWER

CONDUCTORS, ONE #14 GROUND CONDUCTOR. ALL

CONDUCTORS IN A 3/4" CONDUIT. TWO OF THE FOUR

#14 CONTROL OR POWER CONDUCTORS ARE SPARE.

4 #14, #14G., 3/4"C.

(2 #14 SPARE)

METER

WM - WATTMETER

WHM - WATTHOUR METER

WHDM - WATTHOUR DEMAND METER

WHDR - WATTHOUR DEMAND RECORDER

PF - POWER FACTOR METER

ETM - ELAPSED TIME METER

TRANSDUCER

AX - CURRENT TRANSDUCER

WX - WATT TRANSDUCER

RELAY, NO. AS INDICATED

25 - SYNCHRONISM CHECK RELAY

27 - UNDER VOLTAGE RELAY

38 - BEARING PROTECTIVE DEVICE

40 - LOSS OF EXCITATION RELAY

42 - RUNNING CONTACTOR/PILOT RELAY

46 - REVERSE PHASE/PHASE BALANCE/CURRENT RELAY

47 - PHASE SEQUENCE VOLTAGE RELAY

48 - MACHINE OR TRANSFORMER THERMAL RELAY

50 - INSTANTANEOUS OVERCURRENT RELAY

50G - INSTANTANEOUS GROUND

51 - TIME OVER CURRENT RELAY, GROUNDING RESISTOR TYPE

51N - TIME OVERCURRENT RELAY, RESIDUAL TYPE

51V - TIME OVERCURRENT RELAY WITH VOLTAGE

RESTRAINT

59 - OVER VOLTAGE RELAY

60 - NEGATIVE SEQUENCE VOLTAGE RELAY

62 - TIME DELAY RELAY

63 - OVER PRESSURE RELAY

67 - AC DIRECTIONAL OVERCURRENT RELAY

83 - AUTOMATIC SELECTIVE CONTROL OR TRANSFER RELAY

86 - LOCKING-OUT RELAY

87 - DIFFERENTIAL PROTECTIVE RELAY

B - SUFFIX INDICATES "BUS"

G - SUFFIX INDICATES "GENERATOR"

GF - GROUND FAULT

IR - INTERPOSING RELAY

PFR - PHASE FAILURE, PHASE REVERSAL, UNDERVOLTAGE,

OVERVOLTAGE RELAY

ST - SHUNT TRIP

T - SUFFIX INDICATES "TRANSFORMER"

TRP CAP - CAPACITOR TRIP

X - SUFFIX INDICATES "AUXILIARY"

MC1-XXX

TR TRIAD

PHOTOCELLPC

AIC

C/C CENTER TO CENTER

DP

FT

EXIST.

EUC

HP

HTP

GA.

GFS

DIFFERENTIAL PRESSURE

HORSEPOWER

HEATER

ELECTRIC UTILITY CO.

GAUGE

FEET

EXISTING

GROUND FAULT SENSING

ID

JB

LED

KW

KVA

IRP

MFR'S

MCB

MANUFACTURER'S

KILOWATT

MAIN CIRCUIT BREAKER

LIGHT EMITTING DIODE

KILOVOLT-AMPERE

INTERPOSING RELAY PANEL

JUNCTION BOX

INTERNAL DIAMETER

AMPERES INTERRUPTING CAPACITY

PREWIRED

OD

NF

MPR

PL.

PH

PLC

P POLE

OUTSIDE DIAMETER

NON-FUSED

MOTOR PROTECTION RELAY

PHASE

PLATE

REC.

RTU

RTD

REQD.

SHLD. OR SH

SN OR S/N

STC

STA.

CIRCUIT RECLOSURE

REMOTE TERMINAL UNIT

SOLID NEUTRAL

REQUIRED

SHIELD OR SHIELDED

STATION

SIGNAL…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .