This is a specification document for Work Item 2: Compartment Insulation, Renew, part of the larger SPECIFICATION FOR WMEC INSULATION for the US Coast Guard Cutter DILIGENCE.
The work scope requires the Contractor to renew compartment insulation on bulkheads and/or overhead surfaces at designated locations specified in Table 1 of the Statement of Work. No government-furnished property is provided. The specification references multiple Coast Guard drawings (618, 627, 901, and 905 series WMEC 635 drawings) for system reference only, with the critical note that these drawings must not be used for installation methods or material specifications. The Contractor must comply with SFLC Std Spec 0000 (General Requirements) and SFLC Std Spec 6310 (Requirements for Preservation of Ship Structures), along with industry standards including ASTM C534, ASTM F683, and various MIL specifications (MIL-DTL-32585, MIL-I-742, MIL-I-22023, and MIL-A-23054). The primary insulation material specified is Fiberous Glass Cloth-Faced Board, Thermal Insulation (Hullboard) with lamination, conforming to MIL-DTL-32585, Type I. The Contractor must furnish and install all protective measures, handle interferences (overhead panels, wireways, bulkheads, machinery), and install insulation according to three scenarios: thermal treatment without sheathing, thermal treatment with perforated aluminum metal sheathing, or thermal and acoustic treatment with perforated faced materials. All newly installed insulation surfaces must be coated using the "Insulation Surfaces, Fiberglass Sheet/Closed Cell PVC Foam" system specified in SFLC Std Spec 6310, Appendix B.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SOW_Insulation_CGC Resolute (2).docx | DOCX document | |
| Work Item 1 PIPING INSULATION.pdf | ||
| SOW_Insulation_CGC Resolute (1).docx | DOCX document | |
| 52000QR260002936 FAR CLAUSES.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECIFICATION FOR WMEC INSULATION
8 (Rev-1)
WORK ITEM 2: Compartment Insulation, Renew
1. SCOPE
1.1 Intent. This work item describes the requirements for the Contractor to renew compartment insulation (bulkhead and/or overhead) aboard US Coast Guard Cutter DILIGENCE, as designated locations on Table 1 in the SOW.
1.2 Government-furnished property.
None.
2. REFERENCES
COAST GUARD DRAWINGS
Coast Guard Drawing 618 WMEC 635-002, Rev J, Sheathing and Installation Coast Guard Drawing 618 WMEC 635-003, Rev E, Insulation & Sheathing In Machinery Spaces Coast Guard Drawing 618 WMEC 635-004, Rev E, Sheathing & Insulation Dets Hull Galley &
Scullery Coast Guard Drawing 618 WMEC 635-005, Rev A, Insulation Mod 2nd Deck Berthing Coast Guard Drawing 627 WMEC 635-002, Rev B, Sheathing & Insulation Coast Guard Drawing 627 WMEC 635-003, Rev B, Insulation & Sheathing In Machinery Spaces Coast Guard Drawing 627 WMEC 635-004, Rev D, Sheathing And Insulation Hull, Galley, Scullery & Ventilation Duct - Details Coast Guard Drawing 627 WMEC 635-008, Rev A, Insulation Modificaition 2nd Deck Berthing Coast Guard Drawing 901 WMEC 635-001, Rev K, Hull Thermal & Acoustic Insulation
Arrangement and Details Coast Guard Drawing 905 WMEC 635-001, Rev F, Hull Thermal & Acoustic Insulation
Arrangement and Details
NOTE TO CONTRACTOR
Unless otherwise specifically stated in the work item, Coast Guard Drawings are provided for general system reference only and must not be used for installation methods or material specifications.
COAST GUARD PUBLICATIONS
Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2020, General Requirements
SPECIFICATION FOR WMEC INSULATION REPAIRS FY2023
9 (Rev-1)
Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2020, Requirements for Preservation of Ship Structures
OTHER REFERENCES
ASTM International (ASTM) C534, 2020, Specification for Preformed Flexible Elastomeric
Cellular Thermal Insulation in Sheet and Tubular Form ASTM International (ASTM) F683, 2014, Standard Practice for Selection and Application of
Thermal Insulation for Piping and Machinery MIL-A-23054, Aug 1982, Acoustic Absorptive Board; Fiberous Glass, Perforated Fiberous Glass, Cloth Faced MIL-DTL-32585, July 2021, Insulation, Thermal and Acoustic, Fiberglass MIL-I-742, Mar 1980, Insulation Board, Thermal, Fiberous Glass MIL-I-22023, Aug 1982, Insulation Felt, Thermal and Sound Absorbing Felt, Fiberous Glass, Flexible NAVSEA Drawing 804-5773931, Rev-A, Insulation for Compartments, Acoustic and Thermal –
Installation Details
3. REQUIREMENTS
3.1 General.
3.1.1 CIR.
None.
3.1.2 Protective measures. The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection).
3.1.3 Interferences. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences). Known interferences include, but are not limited to the following:
• Overhead panels.
• Wireways.
• Bulkheads.
• Machinery.
3.2 Insulation types. Insulation material type(s) will be designated by the Coast Guard from “Table 3
– Insulation Materials” below.
TABLE 3 – INSULATION MATERIALS
INSULATION DESCRIPTION MATL. SPECIFICATION*
Fiberous Glass Cloth-Faced Board, Thermal Insulation (Hullboard) -w/ lamination.
MIL-DTL-32585, Type I
10 (Rev-1)
*Legacy specifications MIL-I-742, MIL-I-22023, and MIL-A-23054 have been superseded by
MIL-DTL-32585.
3.3 New installation (Thermal treatment where no sheathing is required). The Contractor must install new faced thermal insulation material, over plating surfaces and structural members, as shown on NAVSEA Drawing 804-5773931 or ASTM F683-14 as applicable to system application and insulation type. Coat the newly installed insulation using the system specified for “Insulation Surfaces, Fiberglass Sheet/Closed Cell PVC Foam” in SFLC Std Spec 6310, Appendix B (Cutter and Boat Interior Painting Systems).
3.4 New installation (Thermal treatment where sheathing is required). The Contractor must install new un-faced thermal insulation material, over plating surfaces and structural members, as shown on NAVSEA Drawing 804-5773931 or ASTM F683-14 as applicable to system application and insulation type.
3.4.1 Perforated aluminum metal sheathing. For installation of perforated aluminum metal sheathing the Contractor must refer to Coast Guard Drawings provided for metal sheathing material specification and installation guidance.
3.5 New installation (Thermal and acoustic treatment). The Contractor must install new perforated faced thermal and sound absorptive insulation material over plating surfaces and structural members, in accordance with NAVSEA Drawing 804-5773931 or ASTM F683-14 as applicable to system application and insulation type. Coat the newly installed insulation using the system specified for “Insulation Surfaces, Fiberglass Sheet/Closed Cell PVC Foam” in SFLC Std Spec 6310, Appendix B (Cutter and Boat Interior Painting Systems).
File details come from the government source that posted it. Updated .