WI 0005 USS CANLEY Oily Waste.pdf
PDF 180 KB Posted
- Attached to
- USS CANLEY Oily Waste Removal Federal contract opportunity
- Solicitation number
- N4044326Q0001
About this file
This Request for Quote (RFQ) N4044326Q0001 is for oily waste disposal services for the USS JOHN L CANLEY, located at pier K3/5 JBPHH. The contract requires the contractor to identify, handle, store, transport, and dispose of approximately 15,000 gallons of oily waste, with a bid price to be provided for the bulk waste disposal. The contractor must supply labor, materials, hoses, and connections for vessel waste removal, and comply with all applicable international, federal, state, and local laws and regulations regarding hazardous waste handling and disposal.
The RFQ includes provisions for pricing adjustments based on actual gallons removed, with unit pricing to be determined per gallon. The work is categorized as Category "A" with a contract date of 12/2/2025. Contractors must consult the General Technical Requirements (GTRs) and ensure all workmanship and materials meet the satisfaction of the attending Port Engineer. No owner-furnished equipment is provided, and the contractor is responsible for obtaining all necessary licenses and permits for waste disposal.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFQ N4044326Q0001 Q andA Rev 1.xlsx | XLSX spreadsheet | |
| MSDS - DFM.pdf | ||
| RFQ N4044326Q0001 Q andA.xlsx | XLSX spreadsheet | |
| DREWCLEAN 2000.pdf | ||
| Mobile Delvac.PDF | ||
| RFQ_N4044326Q0001.pdf | ||
| Provisions and Clauses.xlsx | XLSX spreadsheet | |
| WI-0001_REF_7081122_GTR_Searchable.pdf | ||
| Wage Determination 12.3.25.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USS JOHN L CANLEY
WI 0005 CATEGORY "A" 12/2/2025
Oily Waste Disposal RFQ: N4044326Q0001
0005 - 1
0005 OILY WASTE DISPOSAL
1.0 ABSTRACT
1.1 This item describes the requirements for the contractor to provide services to identify, handle, store, transport, and dispose of oily waste from USS JOHN L CANLEY.
2.0 REFERENCES / ENCLOSURES
2.1 Enclosures:
2.1.1 Attached List of Expected Types & Quantities of Wastes
3.0 ITEM LOCATION / DESCRIPTION
3.1 15,000 gallons of oily waste on board USS JOHN L CANLEY, moored pier K3/5 JBPHH.
4.0 OWNER FURNISHED EQUIPMENT AND MATERIAL: None.
5.0 NOTES:
5.1 The Contractor and all Sub-Contractors, regardless of tier, must consult the General Technical Requirements (GTR) to determine applicability to this work item. In performance of this work item, the Contractor and all Sub-Contractors, regardless of tier, must comply with the requirements of all applicable GTR's including but not limited to GTR's 1 through 7 and 21 through 29.
5.2 The Contractor and all Sub-Contractors, regardless of tier, are advised to review other work items under this contract to determine their effect on the work required under this work item.
5.3 Many of the definitions relating to performance of this work are found in Work Item 0001.
5.4 Nothing contained in this work item shall relieve the contractor from complying with applicable international, federal, state, and local laws, codes, ordinances, and regulations, including the obtaining of licenses and permits, in connection with hazardous waste identification, handling, transportation, and disposal in the performance of this contract
6.0 QUALITY ASSURANCE:
6.1 All workmanship, material, parts, testing and material substitutions shall be to the satisfaction of the attending Port Engineer.
7.0 STATEMENT OF WORK
7.1 Disposal of hazardous & oily waste shall be documented in accordance with all local or governmental laws and guidelines.
7.2 Contractor shall provide labor, materials, hoses, connections for the vessel connection.
7.3 Nothing contained in this work item shall relieve the contractor from complying with applicable international, federal, state, and local laws, codes, ordinances, and regulations, including the obtaining of licenses and permits, in connection with hazardous waste identification, handling, transportation, and disposal in the performance of this contract
0005 - 2
7.4 Bulk Oily Waste
7.4.1 The contractor shall provide a bid price for bulk oily waste disposal based on an estimated quantity of 15,000 gallons. In addition, contractor shall bid a unit price per gallon for adjustments to the award price for lesser or greater total gallons removed. Any required adjustments shall be made via contract modification.
8.0 SPECIAL REQUIREMENTS: None Additional
Enclosure 2.2.1: The following is a suggested estimation sheet. Estimated Quantities of hazardous waste expected to be encountered during performance of this work package:
DESCRIPTION EST QUANTITY UNIT PRICE TOTAL
Oily Waste 15,000 US GALLONS
0005 - 3
File details come from the government source that posted it. Updated .