WEXMAC 2.0 ELIN Spreadsheet (N0002324R0001).xlsx
XLSX spreadsheet 260 KB Posted
- Attached to
- Naval Supply Systems Command (NAVSUP) Worldwide Expeditionary Multiple Award Contract (WEXMAC) 2. 0 Federal contract opportunity
- Solicitation number
- N0002324R0001
About this file
This document is a pricing spreadsheet for the Naval Supply Systems Command (NAVSUP) Worldwide Expeditionary Multiple Award Contract (WEXMAC) 2.0 solicitation. The spreadsheet lists various contract line items (CLINs) for providing event support, tents, sanitation, power, water, transportation, and other base operations and life support services. The CLINs include details on the required equipment, quantities, unit of issue, and descriptions. Key services include event support sites, event lots with tents and furnishings, portable sanitary facilities, refrigeration units, generators, and waste management. The spreadsheet is part of the solicitation N0002324R0001, which has a proposal due date of July 31, 2024 at 1500 EST. The contract is for the Department of the Navy NAVSUP to procure worldwide expeditionary support services.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 1. N0002324R0001 Amendment 0001 SF 30.pdf | ||
| 3. N0002324R0001 Amendment 0001 Questions and Answers.xlsx | XLSX spreadsheet | |
| 2. N0002324R0001 Amendment 0001 Conformed SF 33.pdf | ||
| WEXMAC 2.0 Past Performance Questionaire (N0002324R0001).docx | DOCX document | |
| WEXMAC 2.0 Solicitation (N0002324R0001).docx | DOCX document | |
| WEXMAC 1.0 FPDS-NG DATA (N0002324R0001).xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| ELIN_NUMBER | ELIN_TITLE | ELIN_UNIT_OF_ISSUE | ELIN_UNIT_OF_ISSUE_SHORT | SUBCLIN | SUBCLIN_DESCRIPTION | ELIN_EXTENDED_DESCRIPTION | |
| AA01 | EVENT SUPPORT SITE | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.1 | EVENT SUPPORT SITE (ELIN AA01) |
2.1.1 The Event Support Site consists of the following:
2.1.1.1 250 chairs;
2.1.1.2 50 long tables (approximately 2 meters in length);
2.1.1.3 One (1) large BBQ grill with the supporting supplies and equipment (at least 576 square inches);
2.1.1.4 Open or Closed Tents (assorted sizes), which, when combined, shall cover a zone of 300 square meters, with lights that provide sufficient uniform illumination of the space between 750-1000 lux. The tents must be anchored down and strong enough to withstand inclement weather;
2.1.1.5 Three (3) Ice Coolers (70 liters);
2.1.1.6 Three (3) Mist Fans or Space Heaters;
2.1.1.7 20 110-220VAC US outlets with surge protection;
2.1.1.8 Four (4) Portable Sanitary Facility;
2.1.1.9 Four (4) Portable Hand Washing Station;
2.1.1.10 Daily cleaning of the equipment and the Event Support Site area and
2.1.1.11 Transportation, repositioning, mobilization, demobilization, stand-by fee, and labor required to perform the above.
| 2.1.2 | Contractor shall provide a power source capable of supplying power to lighting, 20 110-220VAC US outlets with surge protection, and miscellaneous portable electrical equipment (radios, stereos, hand tools, etc.). The power source shall emit sound levels of less than 84 decibels. Unit Price shall include transportation, set-up, dismantling, labor, necessary consumables, including fuel to operate the power source, mobilization, and demobilization. | |||||||
| AA02 | EVENT LOT (OPEN TENTS) - MINIMUM 20 PERSON CAPACITY | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.2 | EVENT LOT (INCLUDES TENTS, TABLES, CHAIRS, LIGHTING, AND CEILING FANS) (ELIN AA02 – AA0B) |
2.2.1 Contractor shall provide open/closed tents with accessory equipment. The tent package shall include an open/closed tent, lighting, trash cans, ceiling fans, tables and chairs, electrical hookups, cable for power supply, and a generator with fuel already filled to maximum capacity that emits sound levels of less than 84 decibels. The contractor shall clean the tent daily and provide a three-meter perimeter around the tent. Cleaning includes removing trash, sweeping, and mopping up spills. The contractor shall remove all equipment provided upon completion of the services.
2.2.2 Event Lot shall include:
2.2.2.1 20 chairs with at least 250 lbs. capacity
2.2.2.2 10 long tables (at least 6 feet in length and 2 feet in width)
2.2.2.3 Three (3) Mist Fans or Space Heaters
2.2.2.4 20 110-220VAC US outlets with surge protection
2.2.2.5 One (1) Portable Sanitary Facility
2.2.2.6 One (1) Portable Hand Washing Station
2.2.2.7 Transportation, repositioning, mobilization, demobilization, stand-by fee, and labor required to perform the above.
2.2.3 The following ELINs are included:
ELIN AA02: EVENT LOT (OPEN TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA03: EVENT LOT (OPEN TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA04: EVENT LOT (OPEN TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA05: EVENT LOT (OPEN TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA06: EVENT LOT (OPEN TENTS) - MINIMUM 300 PERSON CAPACITY
ELIN AA07: EVENT LOT (CLOSED TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA08: EVENT LOT (CLOSED TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA09: EVENT LOT (CLOSED TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA0A: EVENT LOT (CLOSED TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA0B: EVENT LOT (CLOSED TENTS) - MINIMUM 300 PERSON CAPACITY
2.2.4 ELIN AA02 – AA0B Event Lot Unit of Issue is DAY (DY).
AA03 EVENT LOT (OPEN TENTS) - MINIMUM 50 PERSON CAPACITY DAY DY 0001AA BASE OPERATIONS AND LIFE SUPPORT SERVICES 2.2 EVENT LOT (INCLUDES TENTS, TABLES, CHAIRS, LIGHTING, AND CEILING FANS) (ELIN AA02 – AA0B)
2.2.1 Contractor shall provide open/closed tents with accessory equipment. The tent package shall include an open/closed tent, lighting, trash cans, ceiling fans, tables and chairs, electrical hookups, cable for power supply, and a generator with fuel already filled to maximum capacity that emits sound levels of less than 84 decibels. The contractor shall clean the tent daily and provide a three-meter perimeter around the tent. Cleaning includes removing trash, sweeping, and mopping up spills. The contractor shall remove all equipment provided upon completion of the services.
2.2.2 Event Lot shall include:
2.2.2.1 20 chairs with at least 250 lbs. capacity
2.2.2.2 10 long tables (at least 6 feet in length and 2 feet in width)
2.2.2.3 Three (3) Mist Fans or Space Heaters
2.2.2.4 20 110-220VAC US outlets with surge protection
2.2.2.5 One (1) Portable Sanitary Facility
2.2.2.6 One (1) Portable Hand Washing Station
2.2.2.7 Transportation, repositioning, mobilization, demobilization, stand-by fee, and labor required to perform the above.
2.2.3 The following ELINs are included:
ELIN AA02: EVENT LOT (OPEN TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA03: EVENT LOT (OPEN TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA04: EVENT LOT (OPEN TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA05: EVENT LOT (OPEN TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA06: EVENT LOT (OPEN TENTS) - MINIMUM 300 PERSON CAPACITY
ELIN AA07: EVENT LOT (CLOSED TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA08: EVENT LOT (CLOSED TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA09: EVENT LOT (CLOSED TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA0A: EVENT LOT (CLOSED TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA0B: EVENT LOT (CLOSED TENTS) - MINIMUM 300 PERSON CAPACITY
2.2.4 ELIN AA02 – AA0B Event Lot Unit of Issue is DAY (DY).
AA04 EVENT LOT (OPEN TENTS) - MINIMUM 100 PERSON CAPACITY DAY DY 0001AA BASE OPERATIONS AND LIFE SUPPORT SERVICES 2.2 EVENT LOT (INCLUDES TENTS, TABLES, CHAIRS, LIGHTING, AND CEILING FANS) (ELIN AA02 – AA0B)
2.2.1 Contractor shall provide open/closed tents with accessory equipment. The tent package shall include an open/closed tent, lighting, trash cans, ceiling fans, tables and chairs, electrical hookups, cable for power supply, and a generator with fuel already filled to maximum capacity that emits sound levels of less than 84 decibels. The contractor shall clean the tent daily and provide a three-meter perimeter around the tent. Cleaning includes removing trash, sweeping, and mopping up spills. The contractor shall remove all equipment provided upon completion of the services.
2.2.2 Event Lot shall include:
2.2.2.1 20 chairs with at least 250 lbs. capacity
2.2.2.2 10 long tables (at least 6 feet in length and 2 feet in width)
2.2.2.3 Three (3) Mist Fans or Space Heaters
2.2.2.4 20 110-220VAC US outlets with surge protection
2.2.2.5 One (1) Portable Sanitary Facility
2.2.2.6 One (1) Portable Hand Washing Station
2.2.2.7 Transportation, repositioning, mobilization, demobilization, stand-by fee, and labor required to perform the above.
2.2.3 The following ELINs are included:
ELIN AA02: EVENT LOT (OPEN TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA03: EVENT LOT (OPEN TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA04: EVENT LOT (OPEN TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA05: EVENT LOT (OPEN TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA06: EVENT LOT (OPEN TENTS) - MINIMUM 300 PERSON CAPACITY
ELIN AA07: EVENT LOT (CLOSED TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA08: EVENT LOT (CLOSED TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA09: EVENT LOT (CLOSED TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA0A: EVENT LOT (CLOSED TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA0B: EVENT LOT (CLOSED TENTS) - MINIMUM 300 PERSON CAPACITY
2.2.4 ELIN AA02 – AA0B Event Lot Unit of Issue is DAY (DY).
AA05 EVENT LOT (OPEN TENTS) - MINIMUM 150 PERSON CAPACITY DAY DY 0001AA BASE OPERATIONS AND LIFE SUPPORT SERVICES 2.2 EVENT LOT (INCLUDES TENTS, TABLES, CHAIRS, LIGHTING, AND CEILING FANS) (ELIN AA02 – AA0B)
2.2.1 Contractor shall provide open/closed tents with accessory equipment. The tent package shall include an open/closed tent, lighting, trash cans, ceiling fans, tables and chairs, electrical hookups, cable for power supply, and a generator with fuel already filled to maximum capacity that emits sound levels of less than 84 decibels. The contractor shall clean the tent daily and provide a three-meter perimeter around the tent. Cleaning includes removing trash, sweeping, and mopping up spills. The contractor shall remove all equipment provided upon completion of the services.
2.2.2 Event Lot shall include:
2.2.2.1 20 chairs with at least 250 lbs. capacity
2.2.2.2 10 long tables (at least 6 feet in length and 2 feet in width)
2.2.2.3 Three (3) Mist Fans or Space Heaters
2.2.2.4 20 110-220VAC US outlets with surge protection
2.2.2.5 One (1) Portable Sanitary Facility
2.2.2.6 One (1) Portable Hand Washing Station
2.2.2.7 Transportation, repositioning, mobilization, demobilization, stand-by fee, and labor required to perform the above.
2.2.3 The following ELINs are included:
ELIN AA02: EVENT LOT (OPEN TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA03: EVENT LOT (OPEN TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA04: EVENT LOT (OPEN TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA05: EVENT LOT (OPEN TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA06: EVENT LOT (OPEN TENTS) - MINIMUM 300 PERSON CAPACITY
ELIN AA07: EVENT LOT (CLOSED TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA08: EVENT LOT (CLOSED TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA09: EVENT LOT (CLOSED TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA0A: EVENT LOT (CLOSED TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA0B: EVENT LOT (CLOSED TENTS) - MINIMUM 300 PERSON CAPACITY
2.2.4 ELIN AA02 – AA0B Event Lot Unit of Issue is DAY (DY).
AA06 EVENT LOT (OPEN TENTS) - MINIMUM 300 PERSON CAPACITY DAY DY 0001AA BASE OPERATIONS AND LIFE SUPPORT SERVICES 2.2 EVENT LOT (INCLUDES TENTS, TABLES, CHAIRS, LIGHTING, AND CEILING FANS) (ELIN AA02 – AA0B)
2.2.1 Contractor shall provide open/closed tents with accessory equipment. The tent package shall include an open/closed tent, lighting, trash cans, ceiling fans, tables and chairs, electrical hookups, cable for power supply, and a generator with fuel already filled to maximum capacity that emits sound levels of less than 84 decibels. The contractor shall clean the tent daily and provide a three-meter perimeter around the tent. Cleaning includes removing trash, sweeping, and mopping up spills. The contractor shall remove all equipment provided upon completion of the services.
2.2.2 Event Lot shall include:
2.2.2.1 20 chairs with at least 250 lbs. capacity
2.2.2.2 10 long tables (at least 6 feet in length and 2 feet in width)
2.2.2.3 Three (3) Mist Fans or Space Heaters
2.2.2.4 20 110-220VAC US outlets with surge protection
2.2.2.5 One (1) Portable Sanitary Facility
2.2.2.6 One (1) Portable Hand Washing Station
2.2.2.7 Transportation, repositioning, mobilization, demobilization, stand-by fee, and labor required to perform the above.
2.2.3 The following ELINs are included:
ELIN AA02: EVENT LOT (OPEN TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA03: EVENT LOT (OPEN TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA04: EVENT LOT (OPEN TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA05: EVENT LOT (OPEN TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA06: EVENT LOT (OPEN TENTS) - MINIMUM 300 PERSON CAPACITY
ELIN AA07: EVENT LOT (CLOSED TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA08: EVENT LOT (CLOSED TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA09: EVENT LOT (CLOSED TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA0A: EVENT LOT (CLOSED TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA0B: EVENT LOT (CLOSED TENTS) - MINIMUM 300 PERSON CAPACITY
2.2.4 ELIN AA02 – AA0B Event Lot Unit of Issue is DAY (DY).
AA07 EVENT LOT (CLOSED TENTS) - MINIMUM 20 PERSON CAPACITY DAY DY 0001AA BASE OPERATIONS AND LIFE SUPPORT SERVICES 2.2 EVENT LOT (INCLUDES TENTS, TABLES, CHAIRS, LIGHTING, AND CEILING FANS) (ELIN AA02 – AA0B)
2.2.1 Contractor shall provide open/closed tents with accessory equipment. The tent package shall include an open/closed tent, lighting, trash cans, ceiling fans, tables and chairs, electrical hookups, cable for power supply, and a generator with fuel already filled to maximum capacity that emits sound levels of less than 84 decibels. The contractor shall clean the tent daily and provide a three-meter perimeter around the tent. Cleaning includes removing trash, sweeping, and mopping up spills. The contractor shall remove all equipment provided upon completion of the services.
2.2.2 Event Lot shall include:
2.2.2.1 20 chairs with at least 250 lbs. capacity
2.2.2.2 10 long tables (at least 6 feet in length and 2 feet in width)
2.2.2.3 Three (3) Mist Fans or Space Heaters
2.2.2.4 20 110-220VAC US outlets with surge protection
2.2.2.5 One (1) Portable Sanitary Facility
2.2.2.6 One (1) Portable Hand Washing Station
2.2.2.7 Transportation, repositioning, mobilization, demobilization, stand-by fee, and labor required to perform the above.
2.2.3 The following ELINs are included:
ELIN AA02: EVENT LOT (OPEN TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA03: EVENT LOT (OPEN TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA04: EVENT LOT (OPEN TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA05: EVENT LOT (OPEN TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA06: EVENT LOT (OPEN TENTS) - MINIMUM 300 PERSON CAPACITY
ELIN AA07: EVENT LOT (CLOSED TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA08: EVENT LOT (CLOSED TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA09: EVENT LOT (CLOSED TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA0A: EVENT LOT (CLOSED TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA0B: EVENT LOT (CLOSED TENTS) - MINIMUM 300 PERSON CAPACITY
2.2.4 ELIN AA02 – AA0B Event Lot Unit of Issue is DAY (DY).
AA08 EVENT LOT (CLOSED TENTS) - MINIMUM 50 PERSON CAPACITY DAY DY 0001AA BASE OPERATIONS AND LIFE SUPPORT SERVICES 2.2 EVENT LOT (INCLUDES TENTS, TABLES, CHAIRS, LIGHTING, AND CEILING FANS) (ELIN AA02 – AA0B)
2.2.1 Contractor shall provide open/closed tents with accessory equipment. The tent package shall include an open/closed tent, lighting, trash cans, ceiling fans, tables and chairs, electrical hookups, cable for power supply, and a generator with fuel already filled to maximum capacity that emits sound levels of less than 84 decibels. The contractor shall clean the tent daily and provide a three-meter perimeter around the tent. Cleaning includes removing trash, sweeping, and mopping up spills. The contractor shall remove all equipment provided upon completion of the services.
2.2.2 Event Lot shall include:
2.2.2.1 20 chairs with at least 250 lbs. capacity
2.2.2.2 10 long tables (at least 6 feet in length and 2 feet in width)
2.2.2.3 Three (3) Mist Fans or Space Heaters
2.2.2.4 20 110-220VAC US outlets with surge protection
2.2.2.5 One (1) Portable Sanitary Facility
2.2.2.6 One (1) Portable Hand Washing Station
2.2.2.7 Transportation, repositioning, mobilization, demobilization, stand-by fee, and labor required to perform the above.
2.2.3 The following ELINs are included:
ELIN AA02: EVENT LOT (OPEN TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA03: EVENT LOT (OPEN TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA04: EVENT LOT (OPEN TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA05: EVENT LOT (OPEN TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA06: EVENT LOT (OPEN TENTS) - MINIMUM 300 PERSON CAPACITY
ELIN AA07: EVENT LOT (CLOSED TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA08: EVENT LOT (CLOSED TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA09: EVENT LOT (CLOSED TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA0A: EVENT LOT (CLOSED TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA0B: EVENT LOT (CLOSED TENTS) - MINIMUM 300 PERSON CAPACITY
2.2.4 ELIN AA02 – AA0B Event Lot Unit of Issue is DAY (DY).
AA09 EVENT LOT (CLOSED TENTS) - MINIMUM 100 PERSON CAPACITY DAY DY 0001AA BASE OPERATIONS AND LIFE SUPPORT SERVICES 2.2 EVENT LOT (INCLUDES TENTS, TABLES, CHAIRS, LIGHTING, AND CEILING FANS) (ELIN AA02 – AA0B)
2.2.1 Contractor shall provide open/closed tents with accessory equipment. The tent package shall include an open/closed tent, lighting, trash cans, ceiling fans, tables and chairs, electrical hookups, cable for power supply, and a generator with fuel already filled to maximum capacity that emits sound levels of less than 84 decibels. The contractor shall clean the tent daily and provide a three-meter perimeter around the tent. Cleaning includes removing trash, sweeping, and mopping up spills. The contractor shall remove all equipment provided upon completion of the services.
2.2.2 Event Lot shall include:
2.2.2.1 20 chairs with at least 250 lbs. capacity
2.2.2.2 10 long tables (at least 6 feet in length and 2 feet in width)
2.2.2.3 Three (3) Mist Fans or Space Heaters
2.2.2.4 20 110-220VAC US outlets with surge protection
2.2.2.5 One (1) Portable Sanitary Facility
2.2.2.6 One (1) Portable Hand Washing Station
2.2.2.7 Transportation, repositioning, mobilization, demobilization, stand-by fee, and labor required to perform the above.
2.2.3 The following ELINs are included:
ELIN AA02: EVENT LOT (OPEN TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA03: EVENT LOT (OPEN TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA04: EVENT LOT (OPEN TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA05: EVENT LOT (OPEN TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA06: EVENT LOT (OPEN TENTS) - MINIMUM 300 PERSON CAPACITY
ELIN AA07: EVENT LOT (CLOSED TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA08: EVENT LOT (CLOSED TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA09: EVENT LOT (CLOSED TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA0A: EVENT LOT (CLOSED TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA0B: EVENT LOT (CLOSED TENTS) - MINIMUM 300 PERSON CAPACITY
2.2.4 ELIN AA02 – AA0B Event Lot Unit of Issue is DAY (DY).
AA0A EVENT LOT (CLOSED TENTS) - MINIMUM 150 PERSON CAPACITY DAY DY 0001AA BASE OPERATIONS AND LIFE SUPPORT SERVICES 2.2 EVENT LOT (INCLUDES TENTS, TABLES, CHAIRS, LIGHTING, AND CEILING FANS) (ELIN AA02 – AA0B)
2.2.1 Contractor shall provide open/closed tents with accessory equipment. The tent package shall include an open/closed tent, lighting, trash cans, ceiling fans, tables and chairs, electrical hookups, cable for power supply, and a generator with fuel already filled to maximum capacity that emits sound levels of less than 84 decibels. The contractor shall clean the tent daily and provide a three-meter perimeter around the tent. Cleaning includes removing trash, sweeping, and mopping up spills. The contractor shall remove all equipment provided upon completion of the services.
2.2.2 Event Lot shall include:
2.2.2.1 20 chairs with at least 250 lbs. capacity
2.2.2.2 10 long tables (at least 6 feet in length and 2 feet in width)
2.2.2.3 Three (3) Mist Fans or Space Heaters
2.2.2.4 20 110-220VAC US outlets with surge protection
2.2.2.5 One (1) Portable Sanitary Facility
2.2.2.6 One (1) Portable Hand Washing Station
2.2.2.7 Transportation, repositioning, mobilization, demobilization, stand-by fee, and labor required to perform the above.
2.2.3 The following ELINs are included:
ELIN AA02: EVENT LOT (OPEN TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA03: EVENT LOT (OPEN TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA04: EVENT LOT (OPEN TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA05: EVENT LOT (OPEN TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA06: EVENT LOT (OPEN TENTS) - MINIMUM 300 PERSON CAPACITY
ELIN AA07: EVENT LOT (CLOSED TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA08: EVENT LOT (CLOSED TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA09: EVENT LOT (CLOSED TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA0A: EVENT LOT (CLOSED TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA0B: EVENT LOT (CLOSED TENTS) - MINIMUM 300 PERSON CAPACITY
2.2.4 ELIN AA02 – AA0B Event Lot Unit of Issue is DAY (DY).
AA0B EVENT LOT (CLOSED TENTS) - MINIMUM 300 PERSON CAPACITY DAY DY 0001AA BASE OPERATIONS AND LIFE SUPPORT SERVICES 2.2 EVENT LOT (INCLUDES TENTS, TABLES, CHAIRS, LIGHTING, AND CEILING FANS) (ELIN AA02 – AA0B)
2.2.1 Contractor shall provide open/closed tents with accessory equipment. The tent package shall include an open/closed tent, lighting, trash cans, ceiling fans, tables and chairs, electrical hookups, cable for power supply, and a generator with fuel already filled to maximum capacity that emits sound levels of less than 84 decibels. The contractor shall clean the tent daily and provide a three-meter perimeter around the tent. Cleaning includes removing trash, sweeping, and mopping up spills. The contractor shall remove all equipment provided upon completion of the services.
2.2.2 Event Lot shall include:
2.2.2.1 20 chairs with at least 250 lbs. capacity
2.2.2.2 10 long tables (at least 6 feet in length and 2 feet in width)
2.2.2.3 Three (3) Mist Fans or Space Heaters
2.2.2.4 20 110-220VAC US outlets with surge protection
2.2.2.5 One (1) Portable Sanitary Facility
2.2.2.6 One (1) Portable Hand Washing Station
2.2.2.7 Transportation, repositioning, mobilization, demobilization, stand-by fee, and labor required to perform the above.
2.2.3 The following ELINs are included:
ELIN AA02: EVENT LOT (OPEN TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA03: EVENT LOT (OPEN TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA04: EVENT LOT (OPEN TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA05: EVENT LOT (OPEN TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA06: EVENT LOT (OPEN TENTS) - MINIMUM 300 PERSON CAPACITY
ELIN AA07: EVENT LOT (CLOSED TENTS) - MINIMUM 20 PERSON CAPACITY
ELIN AA08: EVENT LOT (CLOSED TENTS) - MINIMUM 50 PERSON CAPACITY
ELIN AA09: EVENT LOT (CLOSED TENTS) - MINIMUM 100 PERSON CAPACITY
ELIN AA0A: EVENT LOT (CLOSED TENTS) - MINIMUM 150 PERSON CAPACITY
ELIN AA0B: EVENT LOT (CLOSED TENTS) - MINIMUM 300 PERSON CAPACITY
2.2.4 ELIN AA02 – AA0B Event Lot Unit of Issue is DAY (DY).
AA0C PORTABLE SANITARY FACILITIES DAY DY 0001AA BASE OPERATIONS AND LIFE SUPPORT SERVICES 2.3 PORTABLE SANITARY FACILITIES (ELIN AA0C)
2.3.1 The contractor shall provide one (1) portable sanitary facility, which includes one (1) western-style toilet and one (1) urinal, which will include toilet paper and hand sanitizer. The contractor shall ensure that facilities are continuously monitored to ensure that portable sanitary facilities are clean and sanitary, and that toilet paper is available. The contractor shall check portable sanitary facilities at least every three (3) hours to ensure cleanliness and re-stock supplies (i.e., toilet paper). Evidence such as keeping and updating an inspection checklist inside the portable sanitary facilities units is required. Unit Price shall include cleaning and waste removal to ensure clean and sanitary conditions. Unit Price shall include toilet paper and hand sanitizer. The contractor shall dispose of waste in accordance with all applicable Department of Defense, Local, State, Federal, and Host Nations laws, regulations, and standards for services and supplies.
2.3.2 Contractor shall provide American Disabilities Act (ADA) compliant portable sanitary facilities when requested on the RTOP.
| 2.3.3 | ELIN AA0C Portable Sanitary Facilities Unit of Issue is DAY (DY). | |||||||
| AA0D | PORTABLE HAND WASH STATION | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.4 | PORTABLE HAND WASH STATION (ELIN AA0D) |
2.4.1 Contractor shall provide one (1) hand wash station. The portable hand wash station shall include a faucet body, necessary plumbing, potable water, and a hand paper dispenser. Unit Price shall include sanitizing hand liquid soap and potable water to operate the hand wash station. The contractor shall ensure facilities are continuously monitored to ensure portable hand wash stations are clean, sanitary, and liquid soap is available. Unit Price shall include hand paper and hand paper dispenser to allow personnel to dry hands.
| 2.4.2 | ELIN AA0D Portable Hand Wash Station Unit of Issue is DAY (DY). | |||||||
| AA0E | PORTABLE AND TEMPORARY SHOWER FACILITIES | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.5 | PORTABLE AND TEMPORARY SHOWER FACILITIES (ELIN AA0E) |
2.5.1 The Contractor shall provide, install, and maintain self-contained portable shower units and associated equipment, including, but not limited to, potable water tank, grey water tank, and power distribution. The Contractor shall remove all Contractor-furnished equipment upon completion of the exercise or operation.
2.5.2 Showerheads shall be provided at a minimum population ratio of 1:20 and a maximum population ratio of 1:10 at each location.
2.5.3 The Contractor shall provide cleaning services daily. All shower facilities shall be delivered clean and disinfected. Cleaning of the shower facilities shall include the removal of trash, sweeping, mopping, cleaning and disinfecting washbasins and shower stalls, and spot cleaning of the interior and exterior shower facility so that the surfaces are free of debris.
2.5.4 Potable water for Self-contained Portable Shower Facilities(s) must be in accordance with TB MED 577, Sanitary Control and Surveillance of Field Water Supplies. The contractor shall ensure potable water tanks are always at a minimum of twenty-five (25%) full.
2.5.5 The contractor shall remove and dispose of grey water in accordance with allapplicable Department of Defense, Local, State, Federal, and Host Nations laws, regulations, and standards for services and supplies. The contractor shall ensure grey water tanks are no more that ninety percent (90%) full at any time.
2.5.6 The Contractor shall provide, install, maintain and remove generators, fueled by JP8, at the designated locations. Installation includes the set-up of “power grids” by use of distribution boxes and other necessary items to connect the generator and make it user accessible. After set-up is complete, a certified electrician shall inspect wires, ground rods, connections, and equipment to ensure all industry safety standards, codes, regulations, rules, local and host national laws, and guidelines have been adhered to, and the generator set-up will function as intended. The Contractor shall provide the electrician certification certificate and inspection sheet to the COR or authorized ordering officer.
| 2.5.7 | ELIN AA0E Portable and Temporary Shower Facilities Unit of Issue is DAY (DY). | |||||||
| AA0F | REFRIGERATOR UNIT | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.6 | REFRIGERATOR UNIT (ELIN AA0F) |
2.6.1 The contractor shall provide a refrigeration unit with a total capacity equivalent to a 40-foot unit. This can be achieved by providing either a single 40-foot refrigerator unit or two 20-foot units. The choice of configuration should be based on the efficiency of installation, operation, and maintenance, considering the space and logistics of the deployment site.
2.6.2 The refrigeration units shall provide all power generation requirements to operate the refrigeration unit.
2.6.3 The contractor is responsible for the delivery, installation, and commissioning of the refrigerator units at the designated site. This includes ensuring that the units are properly secured, connected to the power supply, and fully operational before acceptance by the requiring activity.
| 2.6.4 | ELIN AA0F Refrigerator Unit of Issue is DAY (DY). | |||||||
| AA0G | SET OF 5 CHAIRS | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.7 | CHAIRS (ELIN AA0G - AA0H) |
2.7.1 Contractor shall provide chairs that are clean and sturdy with a maximum weight capacity of at least 250 lbs.
2.7.2 The following ELINs are included:
ELIN AA0G: SET OF 5 CHAIRS
ELIN AA0H: SET OF 10 CHAIRS
| 2.7.3 | ELIN AA0G - AA0H Chairs Unit of Issue is DAY (DY). | |||||||
| AA0H | SET OF 10 CHAIRS | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.7 | CHAIRS (ELIN AA0G - AA0H) |
2.7.1 Contractor shall provide chairs that are clean and sturdy with a maximum weight capacity of at least 250 lbs.
2.7.2 The following ELINs are included:
ELIN AA0G: SET OF 5 CHAIRS
ELIN AA0H: SET OF 10 CHAIRS
| 2.7.3 | ELIN AA0G - AA0H Chairs Unit of Issue is DAY (DY). | |||||||
| AA0J | SET OF 5 LONG TABLES | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.8 | TABLES (ELIN AA0J - AA0K) |
2.8.1 Contractor shall provide tables that are clean and sturdy. Tables shall be at least 6 feet in length and 2 feet in width.
2.8.2 The following ELINs are included:
ELIN AA0J: SET OF 5 LONG TABLES
ELIN AA0K: SET OF 10 LONG TABLES
| 2.8.3 | ELIN AA0J – AA0K Tables Unit of Issue is DAY (DY). | |||||||
| AA0K | SET OF 10 LONG TABLES | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.8 | TABLES (ELIN AA0J - AA0K) |
2.8.1 Contractor shall provide tables that are clean and sturdy. Tables shall be at least 6 feet in length and 2 feet in width.
2.8.2 The following ELINs are included:
ELIN AA0J: SET OF 5 LONG TABLES
ELIN AA0K: SET OF 10 LONG TABLES
| 2.8.3 | ELIN AA0J – AA0K Tables Unit of Issue is DAY (DY). | |||||||
| AA0L | LARGE BBQ GRILLS | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.9 | LARGE BBQ GRILLS (ELIN AA0L) |
2.9.1 Contractor shall provide one (1) large BBQ Grill with the supporting supplies and equipment included. BBQ Grill shall be at least 576 square inches (3,716 square centimeters). The large BBQ Grill shall be an electric or propane grill. Supplies and equipment shall inclde, but are not limited to, stainless steel spatula, fork, basting brush, and tongs. The contractor shall ensure that the large BBQ Grill and equipment are cleaned in accordance with CDC guidelines prior to or and after the period of performance.
| 2.9.2 | ELIN AA0L Large BBQ Grills Unit of Issue is DAY (DY). | |||||||
| AA0M | OPEN TENT (NON-FORCE PROTECTION) | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.10 | OPEN TENT (NON-FORCE PROTECTION) (ELIN AA0M) |
2.10.1 One (1) unit encompasses assorted sizes that, when combined, shall cover a zone of 300 square meters, with lights that shall provide sufficient uniform illumination of the space between 750-1000 lux. The open tent shall have 20 110-220VAC US outlets with surge protection. The contractor shall provide a power source capable of supplying power to lighting, 20 110-220VAC US outlets with surge protection and miscellaneous portable electrical equipment (radios, stereos, hand tools, etc.). The power source shall emit sound levels of less than 84 decibels. The tent shall be anchored down and strong enough to withstand inclement weather.
| 2.10.2 | ELIN AA0M Open Tent Unit of Issue is DAY (DY). | |||||||
| AA0N | CLOSED TENT (NON-FORCE PROTECTION) | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.11 | CLOSED TENT (NON-FORCE PROTECTION) (ELIN AA0N) |
2.11.1 One (1) unit encompasses assorted sizes that, when combined, shall cover a zone of 300 square meters, with lights that shall provide sufficient uniform illumination of the space between 750-1000 lux. The closed tent shall have 20 110-220VAC US outlets with surge protection. The contractor shall provide a power source capable of supplying power to lighting, 20 110-220VAC US outlets with surge protection, and miscellaneous portable electrical equipment (radios, stereos, hand tools, etc.). The power source shall emit sound levels of less than 84 decibels. The tent shall be enclosed on all sides with an entry door. The tent shall be anchored down and strong enough to withstand inclement weather.
| 2.11.2 | ELIN AA0N Closed Tent Unit of Issue is DAY (DY). | |||||||
| AA0P | 20-FT TRAILER OFFICE | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.12 | 20-FT TRAILER OFFICE (ELIN AA0P) |
2.12.1 Contractor shall provide a 20-FT Trailer Office to include two (2) desks, 10 chairs, air conditioning, and 20 110-220VAC US outlets with surge protection. The contractor shall provide a power source capable of supplying power to lighting and 20 110-220VAC US outlets with surge protection to power miscellaneous portable electrical equipment (radios, stereos, hand tools, etc.). 20 110-220VAC US outlets with surge protection shall have surge protection. Power strips/boards may be used. Power strips/boards shall have surge protection. The power source shall emit sound levels of less than 84 decibels.
| 2.12.2 | ELIN AA0P 20-FT Trailer Office Unit of Issue is DAY (DY). | |||||||
| AA0Q | ICE COOLER | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.13 | ICE COOLER (ELIN AA0Q) |
2.13.1 Contractor shall provide one (1) Ice Cooler with a capacity of least 70 liters. Ice cooler shall have lid and locking mechanism.
| 2.13.2 | ELIN AA0Q Ice Cooler Unit of Issue is DAY (DY). | |||||||
| AA0R | MIST FANS (PORTABLE COOLING DEVICES) | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.14 | MIST FANS (PORTABLE COOLING DEVICES) (ELIN AA0R) |
2.14.1 Contractor shall provide one (1) Mist fan to include tank, water, and power source to operate the Mist Fan. Unit Price shall include transportation, set-up, dismantling and labor, necessary consumables to include fuel to operate the power source, repositioning, mobilization, and demobilization.
2.14.2 Mist Fans shall be rated 600 cubic feet per minute (CFM).
| 2.14.3 | ELIN AA0R Mist Fans (Portable Cooling Devices) Unit of Issue is DAY (DY). | |||||||
| AA0S | 5 KILOWATT GENERATOR | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.15 | PORTABLE ELECTRIC GENERATORS (ELIN AA0S – AA0V) |
2.15.1 Contractor shall provide a portable, gasoline-powered, electric generator capable of supplying power to portable lighting and miscellaneous portable electrical equipment (radios, stereos, hand tools, etc.). Generators shall include a circuit breaker protector including four (4) 50-FT extension cords with enough power boards to support 20 110-220VAC US outlets with surge protection. The contractor shall ensure portable electric generator is available for inspections and testing prior to arrival of requiring activity.
2.15.2 Contractor shall provide uninterrupted power. The contractor shall ensure generators are delivered with all necessary parts in accordance with the operator’s manual and must have a full tank of fuel. The U.S. Government shall not be responsible for returning generators with a full tank or pay to refuel the equipment at the end of the Period of Performance. The contractor shall be responsible to refueling generators. The contractor shall provide 24 hour repair and /or replacement services for the equipment.
2.15.3 The contractor shall manage and maintain emergency backup power generation systems. When emergency generators do not incorporate self-start capabilities, or when otherwise directed at request of the requiring activity, the contractor shall conduct training on generator start to identify U.S. Government personnel.
2.15.3 The following ELINs are included:
ELIN AA0S: 5 KILOWATT GENERATOR
ELIN AA0T: 12.5 KILOWATT GENERATOR
ELIN AA0U: 50 KILOWATT GENERATOR
ELIN AA0V: 100 KILOWATT GENERATOR
2.15.4 ELIN AA0S – AA0V Portable Electric Generators Unit of Issue is DAY (DY).
| 2.16 | PORTABLE HEATERS (ELIN AA0W-AA0X) | |||||||
| AA0T | 12.5 KILOWATT GENERATOR | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.15 | PORTABLE ELECTRIC GENERATORS (ELIN AA0S – AA0V) |
2.15.1 Contractor shall provide a portable, gasoline-powered, electric generator capable of supplying power to portable lighting and miscellaneous portable electrical equipment (radios, stereos, hand tools, etc.). Generators shall include a circuit breaker protector including four (4) 50-FT extension cords with enough power boards to support 20 110-220VAC US outlets with surge protection. The contractor shall ensure portable electric generator is available for inspections and testing prior to arrival of requiring activity.
2.15.2 Contractor shall provide uninterrupted power. The contractor shall ensure generators are delivered with all necessary parts in accordance with the operator’s manual and must have a full tank of fuel. The U.S. Government shall not be responsible for returning generators with a full tank or pay to refuel the equipment at the end of the Period of Performance. The contractor shall be responsible to refueling generators. The contractor shall provide 24 hour repair and /or replacement services for the equipment.
2.15.3 The contractor shall manage and maintain emergency backup power generation systems. When emergency generators do not incorporate self-start capabilities, or when otherwise directed at request of the requiring activity, the contractor shall conduct training on generator start to identify U.S. Government personnel.
2.15.3 The following ELINs are included:
ELIN AA0S: 5 KILOWATT GENERATOR
ELIN AA0T: 12.5 KILOWATT GENERATOR
ELIN AA0U: 50 KILOWATT GENERATOR
ELIN AA0V: 100 KILOWATT GENERATOR
2.15.4 ELIN AA0S – AA0V Portable Electric Generators Unit of Issue is DAY (DY).
| 2.16 | PORTABLE HEATERS (ELIN AA0W-AA0X) | |||||||
| AA0U | 50 KILOWATT GENERATOR | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.15 | PORTABLE ELECTRIC GENERATORS (ELIN AA0S – AA0V) |
2.15.1 Contractor shall provide a portable, gasoline-powered, electric generator capable of supplying power to portable lighting and miscellaneous portable electrical equipment (radios, stereos, hand tools, etc.). Generators shall include a circuit breaker protector including four (4) 50-FT extension cords with enough power boards to support 20 110-220VAC US outlets with surge protection. The contractor shall ensure portable electric generator is available for inspections and testing prior to arrival of requiring activity.
2.15.2 Contractor shall provide uninterrupted power. The contractor shall ensure generators are delivered with all necessary parts in accordance with the operator’s manual and must have a full tank of fuel. The U.S. Government shall not be responsible for returning generators with a full tank or pay to refuel the equipment at the end of the Period of Performance. The contractor shall be responsible to refueling generators. The contractor shall provide 24 hour repair and /or replacement services for the equipment.
2.15.3 The contractor shall manage and maintain emergency backup power generation systems. When emergency generators do not incorporate self-start capabilities, or when otherwise directed at request of the requiring activity, the contractor shall conduct training on generator start to identify U.S. Government personnel.
2.15.3 The following ELINs are included:
ELIN AA0S: 5 KILOWATT GENERATOR
ELIN AA0T: 12.5 KILOWATT GENERATOR
ELIN AA0U: 50 KILOWATT GENERATOR
ELIN AA0V: 100 KILOWATT GENERATOR
2.15.4 ELIN AA0S – AA0V Portable Electric Generators Unit of Issue is DAY (DY).
| 2.16 | PORTABLE HEATERS (ELIN AA0W-AA0X) | |||||||
| AA0V | 100 KILOWATT GENERATOR | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.15 | PORTABLE ELECTRIC GENERATORS (ELIN AA0S – AA0V) |
2.15.1 Contractor shall provide a portable, gasoline-powered, electric generator capable of supplying power to portable lighting and miscellaneous portable electrical equipment (radios, stereos, hand tools, etc.). Generators shall include a circuit breaker protector including four (4) 50-FT extension cords with enough power boards to support 20 110-220VAC US outlets with surge protection. The contractor shall ensure portable electric generator is available for inspections and testing prior to arrival of requiring activity.
2.15.2 Contractor shall provide uninterrupted power. The contractor shall ensure generators are delivered with all necessary parts in accordance with the operator’s manual and must have a full tank of fuel. The U.S. Government shall not be responsible for returning generators with a full tank or pay to refuel the equipment at the end of the Period of Performance. The contractor shall be responsible to refueling generators. The contractor shall provide 24 hour repair and /or replacement services for the equipment.
2.15.3 The contractor shall manage and maintain emergency backup power generation systems. When emergency generators do not incorporate self-start capabilities, or when otherwise directed at request of the requiring activity, the contractor shall conduct training on generator start to identify U.S. Government personnel.
2.15.3 The following ELINs are included:
ELIN AA0S: 5 KILOWATT GENERATOR
ELIN AA0T: 12.5 KILOWATT GENERATOR
ELIN AA0U: 50 KILOWATT GENERATOR
ELIN AA0V: 100 KILOWATT GENERATOR
2.15.4 ELIN AA0S – AA0V Portable Electric Generators Unit of Issue is DAY (DY).
| 2.16 | PORTABLE HEATERS (ELIN AA0W-AA0X) | |||||||
| AA0W | INDOOR PORTABLE HEATER | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.16 | PORTABLE HEATERS (ELIN AA0W-AA0X) |
2.16.1 The contractor shall provide one (1) portable heater, including tank(s), power supply, and/or fuel to operate the portable heater. The portable heater shall be able to provide heat of 200 square foot area. The portable heater shall have a control valve to adjust the temperature to the desired level. Portable heaters shall have automatic emergency shut-off.
2.16.2 The following ELINs are included:
ELIN AA0W INDOOR PORTABLE HEATER. At least 6000 British thermal unit (BTU) ELIN AA0X OUTDOOR PORTABLE HEATER. At least 12000 BTU
| 2.16.3 | ELIN AA0W-AA0X Portable Heaters Unit of Issue is DAY (DY). | |||||||
| AA0X | OUTDOOR PORTABLE HEATER | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.16 | PORTABLE HEATERS (ELIN AA0W-AA0X) |
2.16.1 The contractor shall provide one (1) portable heater, including tank(s), power supply, and/or fuel to operate the portable heater. The portable heater shall be able to provide heat of 200 square foot area. The portable heater shall have a control valve to adjust the temperature to the desired level. Portable heaters shall have automatic emergency shut-off.
2.16.2 The following ELINs are included:
ELIN AA0W INDOOR PORTABLE HEATER. At least 6000 British thermal unit (BTU) ELIN AA0X OUTDOOR PORTABLE HEATER. At least 12000 BTU
| 2.16.3 | ELIN AA0W-AA0X Portable Heaters Unit of Issue is DAY (DY). + | |||||||
| AA0Y | PORTABLE AIR CONDITIONER UNIT | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.17 | PORTABLE AIR CONDITIONER UNIT (ELIN AA0Y) |
2.17.1 The contractor shall provide one (1) portable air conditioner unit to power supply and/or fuel to operate. The portable air conditioner shall be able to provide cooling for a 200-square-foot area. The portable air conditioner shall have a control valve to adjust the temperature to the desired level. The portable conditioner shall have automatic emergency shut-off.
| 2.17.2 | ELIN AA0Y Air Conditioner Unit of Issue is DAY (DY). | |||||||
| AA0Z | INTERPRETER SERVICES (HOURLY) | HOUR | HR | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.18 | INTERPRETER SERVICES (ELIN AA0Z-AA10) |
2.18.1 The contractor shall provide interpreter services when ordered. Interpreters shall have sufficient proficiency in both written and spoken English and the predominant local language and can carry on a casual, fluent conversation in both languages. For specific engagements (as outlined at the task order level), the interpreter shall have adequate proficiency to translate technical aspects of the assigned engagement. The minimum number of hours for interpreter services shall be four (4) hours. If the unit of issue is DAY (DY), the contractor shall provide interpreter services for 24 hours per day. If any interpreter is required to be replaced, the Contractor shall provide a replacement interpreter within 24 hours. If an interpreter is deemed unacceptable by the U.S. Government, the contractor shall replace the unacceptable interpreter within 24 hours of the U.S. Government’s notice at no additional cost to the U.S. Government. The U.S. Government will provide a start time and location for each interpreter the day prior to the service’s start date. The contractor shall not deviate from the start time and location unless approved by an authorized ordering officer.
2.18.2 The contractor shall provide meals and lodging for all interpreters. The contractor shall ensure interpreters are granted access to all places of performance in support of this requirement. The contractor shall ensure interpreters have transportation to all events if required. The contractor shall ensure interpreters are prepared to perform work on time at each event. The contractor shall ensure the interpreter's working hours and schedule comply with all applicable Department of Defense, Local, State, Federal, and Host Nations laws, regulations, and standards for services and supplies.
2.18.3 The contractor shall provide the U.S. Government representative with a list of interpreters at least two (2) days before the assignment for each engagement. The list shall contain the names, phone numbers, emails, and specific qualifications of the approved interpreters. The U.S. Government reserves the right to provide a required template for the contractor to provide the list of interpreters per engagement.
2.18.4 ELIN AA0Z Interpreter Services (Hourly) units of issues is HOUR (HR).
| 2.18.5 | ELIN AA10 Interpreter Services (Daily) unit of issue is DAY (DY). | |||||||
| AA10 | INTERPRETER SERVICES (DAILY) | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.18 | INTERPRETER SERVICES (ELIN AA0Z-AA10) |
2.18.1 The contractor shall provide interpreter services when ordered. Interpreters shall have sufficient proficiency in both written and spoken English and the predominant local language and can carry on a casual, fluent conversation in both languages. For specific engagements (as outlined at the task order level), the interpreter shall have adequate proficiency to translate technical aspects of the assigned engagement. The minimum number of hours for interpreter services shall be four (4) hours. If the unit of issue is DAY (DY), the contractor shall provide interpreter services for 24 hours per day. If any interpreter is required to be replaced, the Contractor shall provide a replacement interpreter within 24 hours. If an interpreter is deemed unacceptable by the U.S. Government, the contractor shall replace the unacceptable interpreter within 24 hours of the U.S. Government’s notice at no additional cost to the U.S. Government. The U.S. Government will provide a start time and location for each interpreter the day prior to the service’s start date. The contractor shall not deviate from the start time and location unless approved by an authorized ordering officer.
2.18.2 The contractor shall provide meals and lodging for all interpreters. The contractor shall ensure interpreters are granted access to all places of performance in support of this requirement. The contractor shall ensure interpreters have transportation to all events if required. The contractor shall ensure interpreters are prepared to perform work on time at each event. The contractor shall ensure the interpreter's working hours and schedule comply with all applicable Department of Defense, Local, State, Federal, and Host Nations laws, regulations, and standards for services and supplies.
2.18.3 The contractor shall provide the U.S. Government representative with a list of interpreters at least two (2) days before the assignment for each engagement. The list shall contain the names, phone numbers, emails, and specific qualifications of the approved interpreters. The U.S. Government reserves the right to provide a required template for the contractor to provide the list of interpreters per engagement.
2.18.4 ELIN AA0Z Interpreter Services (Hourly) units of issues is HOUR (HR).
| 2.18.5 | ELIN AA10 Interpreter Services (Daily) unit of issue is DAY (DY). | |||||||
| AA11 | 32 GALLON TRASH CAN & REMOVAL (REGULAR TRASH & FOOD WASTE) | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.19 | 32 GALLON TRASH CAN & REMOVAL (ELIN AA11-AA15) |
2.19.1 The contractor shall provide one (1) trash can with 32-gallon capacity. Trash cans shall include a lid with a security-locking feature that locks in odors and must feature reinforced handles. The contractor shall ensure that trash cans are emptied when they are at 75% capacity.
2.19.2 The following ELINs are included:
ELIN AA11: 32 GALLON TRASH CAN & REMOVAL (REGULAR TRASH & FOOD
WASTE)
ELIN AA12: 32 GALLON TRASH CAN & REMOVAL (MEDICAL WASTE)
ELIN AA13: 32 GALLON TRASH CAN & REMOVAL (CONSTRUCTION DEBRIS,
CONCRETE, SOIL, RUBBLE)
ELIN AA14: 32 GALLON TRASH CAN & REMOVAL (METALS RECYCLE)
ELIN AA15: 32 GALLON TRASH CAN & REMOVAL (PLASTICS/GLASS RECYCLE)
| 2.19.3 | ELIN AA11-AA15 32 GALLON TRASH CAN & REMOVAL Unit of Issue is DAY (DY). | |||||||
| AA12 | 32 GALLON TRASH CAN & REMOVAL (MEDICAL WASTE) | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.19 | 32 GALLON TRASH CAN & REMOVAL (ELIN AA11-AA15) |
2.19.1 The contractor shall provide one (1) trash can with 32-gallon capacity. Trash cans shall include a lid with a security-locking feature that locks in odors and must feature reinforced handles. The contractor shall ensure that trash cans are emptied when they are at 75% capacity.
2.19.2 The following ELINs are included:
ELIN AA11: 32 GALLON TRASH CAN & REMOVAL (REGULAR TRASH & FOOD
WASTE)
ELIN AA12: 32 GALLON TRASH CAN & REMOVAL (MEDICAL WASTE)
ELIN AA13: 32 GALLON TRASH CAN & REMOVAL (CONSTRUCTION DEBRIS,
CONCRETE, SOIL, RUBBLE)
ELIN AA14: 32 GALLON TRASH CAN & REMOVAL (METALS RECYCLE)
ELIN AA15: 32 GALLON TRASH CAN & REMOVAL (PLASTICS/GLASS RECYCLE)
| 2.19.3 | ELIN AA11-AA15 32 GALLON TRASH CAN & REMOVAL Unit of Issue is DAY (DY). | |||||||
| AA13 | 32 GALLON TRASH CAN & REMOVAL (CONSTRUCTION DEBRIS, CONCRETE, SOIL, RUBBLE) | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.19 | 32 GALLON TRASH CAN & REMOVAL (ELIN AA11-AA15) |
2.19.1 The contractor shall provide one (1) trash can with 32-gallon capacity. Trash cans shall include a lid with a security-locking feature that locks in odors and must feature reinforced handles. The contractor shall ensure that trash cans are emptied when they are at 75% capacity.
2.19.2 The following ELINs are included:
ELIN AA11: 32 GALLON TRASH CAN & REMOVAL (REGULAR TRASH & FOOD
WASTE)
ELIN AA12: 32 GALLON TRASH CAN & REMOVAL (MEDICAL WASTE)
ELIN AA13: 32 GALLON TRASH CAN & REMOVAL (CONSTRUCTION DEBRIS,
CONCRETE, SOIL, RUBBLE)
ELIN AA14: 32 GALLON TRASH CAN & REMOVAL (METALS RECYCLE)
ELIN AA15: 32 GALLON TRASH CAN & REMOVAL (PLASTICS/GLASS RECYCLE)
| 2.19.3 | ELIN AA11-AA15 32 GALLON TRASH CAN & REMOVAL Unit of Issue is DAY (DY). | |||||||
| AA14 | 32 GALLON TRASH CAN & REMOVAL (METALS RECYCLE) | DAY | DY | 0001AA | BASE OPERATIONS AND LIFE SUPPORT SERVICES | 2.19 | 32 GALLON TRASH CAN & REMOVAL (ELIN AA11-AA15) |
2.19.1 The contractor shall provide one (1) trash can with 32-gallon capacity. Trash cans shall include a lid with a security-locking feature that locks in odors and must feature reinforced handles. The contractor shall ensure that trash cans are emptied when they are at 75% capacity.
2.19.2 The following ELINs are…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .