WCC 260-B5260-075 (M25WC153) Project Drawings 2026-09-03.pdf
PDF 4 MB Posted
- Solicitation number
- DBB-129825
- Issued by
- Wise County, Virginia
About this file
This document is a project drawings file for the Replace Grayson Hall Elevator and Loading Dock project at Wytheville Community College, a Virginia Community College System initiative. The project, identified as Project Code #260-B5260-075 (M25WC153), involves the replacement of an elevator and installation of a loading dock leveler at Grayson Hall located in Wytheville, Virginia. Sealed bids are due November 12, 2026, at 2:00 p.m., with bids to be opened publicly and read aloud on November 13, 2026, at 2:00 p.m. at Virginia Community College System headquarters in Richmond. A pre-bid conference is scheduled for October 20, 2026, at 10:00 a.m. at Wytheville Community College in Grayson Hall Room 111, Johnson Lobby. Attendance at the pre-bid conference is optional but highly recommended. Bids may be submitted electronically through eVA or by hand delivery to the Virginia Community College System, Attention: Mrs. Sibyl Roberts, 300 Arboretum Place, Suite 200, Richmond, Virginia 23236. Bid modifications are accepted via fax to (804) 819-4762 with a copy sent to sroberts@vccs.edu.
A Standard Commonwealth Bid Bond (form CO-10.2) and contract security are required regardless of bid amount. All contractors must be registered vendors in eVA and must process all pay applications and invoices through e-Builder, the owner's web-based project management software, at no cost. The owner will provide necessary training and support for e-Builder use. Questions and clarifications should be directed to Mrs. Sibyl Roberts at (804) 819-4918. The project drawings document, dated September 3, 2026, provides the technical specifications and details necessary for bidders to prepare accurate bids for this construction project.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT DESCRIPTION:
THIS PROJECT INCLUDES THE REPLACEMENT OF AN EXISTING ELEVATOR LOCATED IN
GRAYSON HALL ON THE CAMPUS OF WYTHEVILLE COMMUNITY COLLEGE AND THE
INSTALLATION OF EDGE OF DOCK LEVELER AT THE LOADING DOCK.
POINT OF CONTACT:
VCCS PROJECT MANAGER: CLINT A. BAILEY WCC CONTACT: JOSEPH COLLINS
SENIOR CAPITAL OUTLAY PROGRAM MANAGER WYTHEVILLE COMMUNITY COLLEGE
300 ARBORETUM PLACE SUITE 200 1000 E MAIN ST
RICHMOND, VA 23236 WYTHEVILLE, VA 24382
C: (434) 738-8299 276-613-4461
E-MAIL: cbailey@vccs.edu E-MAIL: JCollins@wcc.vccs.edu
DIG NOTICE:
N/A: NO EXTERIOR WORK IS PART OF THE PROJECT.
HAZARDOUS MATERIALS STATEMENT
LEAD
1. AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS HAS BEEN
CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS REPORT IS PROVIDED
FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT IS THE CONTRACTOR’S
RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL SAFETY AND HEALTH (VOSH)
REGULATIONS AS THEY PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. ALL LEAD AND LEAD-
COATED BUILDING COMPONENTS SHALL BE RECYCLED TO THE EXTENT POSSIBLE.
ASBESTOS
1. AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE AREA
INDICATED. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN APPENDIX TO THE PROJECT
SPECIFICATIONS. ASBESTOS-CONTAINING BUILDING MATERIALS SHALL NOT BE DISTURBED IN
THIS WORK EXCEPT WHERE SPECIFICALLY INDICATED AND REQUIRED. WHERE SUCH ACTIONS
ARE REQUIRED, THE CONTRACTOR SHALL HAVE THE ACM REMOVED BY A LICENSED ASBESTOS
CONTRACTOR USING APPROVED PROCEDURES AS SPECIFIED. THE WORK REQUIRED FOR
ASBESTOS ABATEMENT IS PERMITTED WITHIN THE OVERALL BUILDING PERMIT ISSUED. THE
ACM THAT IS TO REMAIN AND THE NEW NON ASBESTOS-CONTAINING MATERIAL SHALL BE
LABELED ACCORDINGLY. THE ASBESTOS ABATEMENT CONTRACTOR SHALL MARK UP THE AS-
BUILT DRAWINGS RESULTING FROM ITS WORK TO INCLUDE AREAS WHERE ASBESTOS WAS
ABATED, AREAS WHERE ASBESTOS WAS ENCAPSULATED, AND AREAS WHERE ACM EXIST BUT
WERE LEFT IN PLACE. THE GENERAL CONTRACTOR SHALL REVIEW AND CERTIFY THE LOCATIONS
WHERE ACM WAS ABATED, AREAS WHERE ACM WAS ENCAPSULATED AND AREAS WHERE ACM
WAS LEFT IN PLACE AS MARKED ON THE AS-BUILT DRAWINGS AND WILL PROVIDE THE
DRAWINGS TO THE ARCHITECT. NO ASBESTOS CONTAINING MATERIALS SHALL BE USED ON THE
PROJECT.
CODES & REGULATIONS
2021 VIRGINIA EXISTING BUILDING CODE, (VEBC) - LEVEL 2 ALTERATION
2021 VIRGINIA CONSTRUCTION CODE (VCC), PART 1 OF THE VIRGINIA UNIFORM STATEWIDE
BUILDING CODE (VUSBC)
2021 VIRGINIA STATEWIDE FIRE PREVENTION CODE (VSFPC)
2021 INTERNATIONAL FIRE CODE (IFC) AS REFERENCED BY THE VIRGINIA CODES
2019 NFPA 13 AUTOMATIC SPRINKLER SYSTEMS
2019 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE
2020 NFPA 70 NATIONAL ELECTRICAL CODE
2019 NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES
2021 VIRGINIA MECHANICAL CODE (VMC)
2021 VIRGINIA PLUMBING CODE (VPC)
2021 VIRGINIA FUEL GAS CODE (VFGC)
2021 VIRGINIA ENERGY CONSERVATION CODE (VECC)
2019 ASME/A17.1 SAFETY CODE FOR ELEVATORS AND ESCALATORS
2026 COMMONWEALTH OF VIRGINIA CONSTRUCTION AND PROFESSIONAL SERVICE MANUAL (CPSM), REVISION 0, JULY 31, 2026
ADA 90-TITLE II (ASAD CHAPTER 2 FOR SCOPING, A117.1-2017 CHAPTERS 1 AND 3 THROUGH 11 FOR
TECHNICAL REQUIREMENTS)
2022 VIRGINIA COMMUNITY COLLEGE CONSTRUCTION AND PROFESSIONAL SERVICES MANUAL (VCCS)
VIRGINIA ENERGY CONSERVATION
CODE COMPLIANCE STATEMENT
1. IN ACCORD WITH THE VIRGINIA ENERGY CONSERVATION CODE (VECC), THE
BUILDING SHALL COMPLY WITH VECC SECTIONS C402 THROUGH C405.
PROJECT LOCATIONPROJECT LOCATION
NORTH CAROLINA
VIRGINIA
WEST
VIRGINIA
WASHINGTON D.C.
RICHMOND
RALEIGH
ROANOKE
ABINGDON
BRISTOL
BIG STONE GAP
COEBURN
RICHLANDS
GRUNDY
PRINCETONN FARMVILLE
WYTHEVILLE
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
VICINITY MAP
726 Auburn Avenue
Radford, Virginia 24141
P: (540) 633-1897, F: (540) 633-1896 www.T-L.com
EST. 1956
LOCATION MAP
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
PREPARED FOR
/3
/2
:2
:4
A M
C
U se rs \t re y_ h a rd e n \D o cu m e n ts
\1
W
C C
G ra y so n H a ll v2 th a rd e n
B
N
R .r v t
G001
19736
09/03/2026
TAH
EFS
EFS
IS
S
U E
D F
O R
B
ID
S
PROJECT NO.: 19736
09/03/2026
ISSUED FOR BIDS
WCC GRAYSON HALL ELEVATOR AND LOADING
DOCK
1000 E MAIN ST, WYTHEVILLE, VA 24382
PROJECT CODE:260-B5260-075 / M25WC153
WYTHEVILLE, VIRGINIA
WYTHEVILLE COMMUNITY COLLEGE
W C
C G
R A
YS
O
N H
A
LL
E
LE
V A
TO
R
A N
D
LO
A
D
IN
G D
O C
K W
Y T
H E
V
IL
LE
V
IR
G
IN
IA
TI
TL
E
SH
EE
T
SHEET INDEX
SHEET NAME SHEET NUMBER
GENERAL
TITLE SHEET G001
PROJECT INFORMATION AND DATA G002
LIFE SAFETY
FIRE PROTECTION PLAN LS101
FIRE PROTECTION PLAN LS102
ARCHITECTURAL
DEMOLITION FLOOR PLAN AD101
NEW WORK FLOOR PLAN A101
ENLARGED PLANS AND INTERIOR ELEVATIONS A401
STRUCTURAL
LOADING DOCK PLAN S100
FIRE PROTECTION
FIRE PROTECTION NOTES, SPECIFICATIONS & LEGEND FP001
1ST/2ND FLOOR - FIRE PROTECTION FP101
PLUMBING
PLUMBING NOTES, SPECIFICATIONS & LEGEND P001
FIRESTOP DETAILS P002
FIRESTOP DETAILS P003
1ST/2ND FLOOR - PLUMBING P101
MECHANICAL
MECHANICAL NOTES, SCHEDULES, SPECIFICATIONS & LEGEND M001
MECHANICAL DETAILS M002
FIRST FLOOR PLAN M100
ELECTRICAL
ELECTRICAL NOTES, LEGEND, ABBREVIATION AND PARTIAL ONE-LINE E001
ELECTRICAL PLANS E101
ENLARGED ELECTRICAL PLANS E102
DETAILS, PARTIAL FA MATRIX, SCHEDULES, AND PARTIAL FA RISER E701
FOR STRUCTURAL ONLY FOR ELECTRICAL ONLYFOR ARCHITECTURAL AND LIFE
SAFETY ONLY
FOR MECHANICAL AND
PLUMBING ONLY
N o
D a te
R e v is io n s
N
BUILDING AREA SUMMARY
CODE BUILDING AREA:
GROSS BUILDING AREA:
BUILDING PERIMETER:
42,380 SF
44,065 SF
779 FT
FIRE-RESISTANCE RATING
REQUIREMENTS
BUILDING ELEMENT
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING
ELEMENTS (HOURS)
FIRE RATING
(EXCERPT FROM VUSBC TABLE 601, UON)
BEARING WALLS
EXTERIOR
INTERIOR
0 HR
0 HR
CONSTRUCTION TYPE: IIB
PRIMARY STRUCTURAL FRAME 0 HR
NONBEARING WALLS & PARTITIONS
EXTERIOR (VUSBC TABLE 602) 0 HR
NONBEARING WALLS & PARTITIONS
INTERIOR 0 HR
FLOOR CONSTRUCTION & SECONDARY MEMBERS 0 HR
ROOF CONSTRUCTION & SECONDARY MEMBERS 0 HR
BUILDING ELEMENT FIRE RATING
MISCELLANEOUS FIRE-RESISTANCE RATING REQUIREMENTS
CORRIDORS (VUSBC TABLE 1020.2) 0 HR
DRAFTSTOPPING REQUIREMENTS PER VUSBC 718.4.3
ATTICS OR CONCEALED ROOF SPACES 3000 SF MAX AREA
GENERAL INFORMATION
ELEVATOR REPLACEMENT & LOADING DOCK IMPROVEMENTS.
NOTE: IT IS INTENDED THAT THE ELEVATOR REPLACEMENT OCCUR DURING A
BREAK IN THE UNIVERSITY'S OPERATION SCHEDULE WHEN THE BUILDING WILL BE
UNOCCUPIED.
SCOPE:
CONSTRUCTION CLASSIFICATION:
CONSTRUCTION TYPE: IIB
EXISTING BUILDING IS PARTIALLY SPRINKLERED PER NFPA 13 (ALL MECHANICAL,
CUSTODIAL, AND STORAGE ROOMS)
OCCUPANCY:
DESCRIPTION: MIXED-USE, SEPARATED
OCCUPANCY CLASSIFICATION: HIGHER EDUCATION - BUSINESS (B)/ASSEMBLY (A-3)
MAXIMUM TRAVEL DISTANCES:
COMMON PATH OF TRAVEL (VUSBC 1006.2.1):
EXIT ACCESS TRAVEL DISTANCE (VUSBC TABLE 1017.2):
DEAD ENDS (VEBC 603.3):
75 FT MAX
250 FT MAX
50 FT MAX
INTERIOR FINISH REQUIREMENTS:
CORRIDOR WALLS & CEILINGS (VUSBC TABLE 803.13):
-CLASS C
FLOORS (VUSBC 804.4.2):
-CLASS II
FLAME SPREAD INDEX 76-200
SMOKE-DEVELOPED INDEX 0-450
ROOM & ENCLOSED SPACE WALLS & CEILINGS (VUSBC TABLE 803.13):
-CLASS C
FLAME SPREAD INDEX 76-200
SMOKE-DEVELOPED INDEX 0-450
CRITICAL RADIANT FLUX NOT LESS THAN 0.22 WATTS/CM
REFER TO DESIGN CRITERIA ON THIS SHEET.
DESIGN LIVE LOADS:
ASBESTOS CONTAINING MATERIALS AND/OR PAINTS CONTAINING LEAD SHALL
NOT BE USED IN ANY FORM ON THE PROJECT.
EXIT ENCLOSURES & EXIT PASSAGEWAYS (VUSBC TABLE 803.13):
-CLASS B
FLAME SPREAD INDEX 26-75
SMOKE-DEVELOPED INDEX 0-450
(VCC CHAPTER 8 PER VEBC 602.3.1)
VIRGINIA EXISTING BUILDING CODE
CHAPTER 6 ALTERATIONS
SECTION 601
601.2.2 LEVEL 2
LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF
SECTIONS 602 AND 603 AND SHALL INCLUDE THE FOLLWING:
1. THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW.
2. THE ADDITION OR ELIMINATION OF ANY WALL, FLOOR, OR CEILING ASSEMBLY.
3. THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM.
4. THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT, MATERIALS, ELEMENTS,
OR FIXTURES.
SECTION 602
602.3.1 INTERIOR FINISHES AND TRIM
ALL NEWLY INSTALLED INTERIOR FINISH AND TRIM MATERIALS AND WALL,
FLOOR AND CEILING FINISHES SHALL COMPLY WITH CHAPTER 8 OF THE VCC.
602.3.2 MATERIALS AND METHODS
ALL NEW BUILDING ELEMENTS AND MATERIALS SHALL COMPLY WITH THE
MATERIALS AND METHODS REQUIREMENTS IN THE VCC, INTERNATIONAL ENERGY
CONSERVATION CODE, INTERNATIONAL MECHANICAL CODE AND INTERNATIONAL
PLUMBING CODE, AS APPLICABLE, THAT SPECIFY MATERIAL STANDARDS, DETAIL OF
INSTALLATION AND CONNECTION, JOINTS, PENETRATIONS AND CONTINUITY OF ANY
ELEMENTS, COMPONENT OR SYSTEM IN THE BUILDING.
CODES & REGULATIONS
2021 VIRGINIA EXISTING BUILDING CODE, (VEBC) - LEVEL 2 ALTERATION
2021 VIRGINIA CONSTRUCTION CODE (VCC), PART 1 OF THE VIRGINIA UNIFORM STATEWIDE
BUILDING CODE (VUSBC)
2021 VIRGINIA STATEWIDE FIRE PREVENTION CODE (VSFPC)
2021 INTERNATIONAL FIRE CODE (IFC) AS REFERENCED BY THE VIRGINIA CODES
2019 NFPA 13 AUTOMATIC SPRINKLER SYSTEMS
2019 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE
2020 NFPA 70 NATIONAL ELECTRICAL CODE
2019 NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES
2021 VIRGINIA MECHANICAL CODE (VMC)
2021 VIRGINIA PLUMBING CODE (VPC)
2021 VIRGINIA FUEL GAS CODE (VFGC)
2021 VIRGINIA ENERGY CONSERVATION CODE (VECC)
2019 ASME/A17.1 SAFETY CODE FOR ELEVATORS AND ESCALATORS
2026 COMMONWEALTH OF VIRGINIA CONSTRUCTION AND PROFESSIONAL SERVICE MANUAL (CPSM), REVISION 0, JULY 31, 2026
ADA 90-TITLE II (ASAD CHAPTER 2 FOR SCOPING, A117.1-2017 CHAPTERS 1 AND 3 THROUGH 11 FOR
TECHNICAL REQUIREMENTS)
2022 VIRGINIA COMMUNITY COLLEGE CONSTRUCTION AND PROFESSIONAL SERVICES MANUAL (VCCS)
OCCUPANCY LOAD SUMMARY
NOTE: NEW WORK WILL NOT CHANGE THE EXISTING OCCUPANT LOAD.
A101A
CONSTRUCTION NOTE DESIGNATION
TOILET & BATH ACCESSORY DESIGNATION
A101
ROOM NAME
PARTITION TYPE DESIGNATION
NEW CONSTRUCTION
EXISTING CONSTRUCTION
EXISTING TO BE DEMOLISHED
DOOR/OPENING NUMBER DESIGNATION
ROOM NUMBER DESIGNATION
FLOOR LEVEL
SUFFIX AT MULTIPLE
DOOR/OPENING LOCATIONS
DOOR/OPENING NUMBER
BUILDING AREA
ROOM NUMBER
BUILDING AREA
FLOOR LEVEL
DEMOLITION NOTE DESIGNATION
E00 WINDOW TYPE DESIGNATION
(E=EXTERIOR / I=INTERIOR)
1 REVISION NUMBER DESIGNATION
A101A101
1 SIM
SECTION CUT DESIGNATION
(DETAIL DESIGNATION SIMILAR)
NUMBER INDICATES
SECTION OR DETAIL
SHEET NUMBER WHERE
SECTION OR DETAIL IS
DRAWN
SHEET NUMBER WHERE
SECTION OR DETAIL IS
TAKEN
ELEVATION DESIGNATION
SIM A101
A101
SIM1
A101
A101
NUMBER INDICATES ELEVATION
SHEET NUMBER WHERE
ELEVATION IS TAKEN
SHEET NUMBER WHERE
ELEVATION IS DRAWN
INTERIOR
ELEVATION
EXTERIOR
ELEVATION
MATCHLINE
0'-0"
SPOT ELEVATION
00 COLUMN LINE/HEAD
DATUM LINE
LEVEL
0'-0"
AREA 'A'
KEY PLAN AREA
XX-00
OPENING FRAME DESIGNATION
NUMBER
MATERIAL
PLAN NORTH
NORTH ARROW
(REFER TO CIVIL PLAN SHEETS FOR TRUE
NORTH WHEN APPLICABLE TO THE PROJECT)
AREA 'B'
A101, A102...
ADDITIONAL
SHEET
REFERENCES
ROOM SIGNAGE DESIGNATION
ARCHITECTURAL LEGEND
GENERAL CONSTRUCTION NOTES:
1. ALL WORK SHALL BE PERFORMED IN OBSERVANCE OF STATE AND FEDERAL CODES AND REGULATIONS.
2. EXISTING CONDITIONS SHOWN HEREIN WERE TAKEN FROM SITE OBSERVATIONS AND COMPLETE OR PARTIAL
SETS OF ORIGINAL DESIGN DRAWINGS WHEN MADE AVAILABLE. ANY DISCREPANCIES BETWEEN THE
DRAWINGS AND ACTUAL BUILT CONDITIONS ARE TO BE REPORTED TO THE ARCHITECT PRIOR TO
COMMENCEMENT OF WORK.
3. LOOSE FURNISHINGS, APPLIANCES, AND EQUIPMENT ARE NOT INCLUDED WITHIN THIS PROJECT'S SCOPE
(NIC), UNLESS OTHERWISE NOTED.
4. DO NOT "SCALE" DRAWINGS. USE DIMENSIONAL INFORMATION PROVIDED ONLY. FOR DIMENSIONS NOT
SHOWN OR IN QUESTION, CONTRACTOR SHALL REQUEST CLARIFICATION FROM ARCHITECT PRIOR TO
PROCEEDING.
5. ALL DIMENSIONS ARE MEASURED TO FACE OF METAL AND/OR WOOD STUDS OR MASONRY CONSTRUCTION
UNLESS OTHERWISE NOTED.
6. ALL DIMENSIONS NOTED AS "CLEAR," ARE FROM FACE OF FINISH TO FACE OF FINISH.
7. REFER TO LIFE SAFETY DRAWINGS FOR LOCATIONS OF FIRE-RATED CONSTRUCTION AND FIRE EXTINGUISHER
LOCATIONS.
CONCRETE
MASONRY UNIT
CONCRETE
STONE VENEER
FACE BRICK
GYPSUM WALLBOARD
METAL/WOOD STUD
INSULATION - BATT
INSULATION - RIGID
STEEL
CAVITY DRAINAGE
MATERIAL
FINISH CARPENTRY
EARTH
GRAVEL
PLYWOOD
GROUT
INSULATION - SPRAY
ROUGH CARPENTRY
BLOCKING
ALUMINUM
MATERIAL LEGEND
DESIGN CRITERIA
1. GOVERNING CODES
2021 VIRGINIA CONSTRUCTION CODE (VCC), PART I OF VIRGINIA UNIFORM STATEWIDE BUILDING CODE
(USBC) EFFECTIVE JANUARY 18, 2024
2021 VIRGINIA EXISTING BUILDING CODE (VEBC), PART II OF VIRGINIA UNIFORM STATEWIDE BUILDING
CODE (USBC) EFFECTIVE JANUARY 18, 2024
2. SNOW LOADS
ULTIMATE GROUND SNOW LOADS (Pg) 51 PSF
ULTIMATE FLAT ROOF SNOW LOAD (Pf) 40 PSF
ASD FLAT ROOF SNOW LOAD (Pf) TO BE USED TO CALCULATE DRIFT 28 PSF
MINIMUM ULTIMATE BALANCED FLAT ROOF SNOW LOAD 35 PSF
MINIMUM ASD BALANCED FLAT ROOF SNOW LOAD 24.5 PSF
WINTER WIND PARAMETER (W2) 0.35
RISK CATEGORY III
SNOW EXPOSURE FACTOR (Ce) 1.0
THERMAL FACTOR (Ct) 1.12
3. WIND LOADS
BASIC DESIGN WIND SPEED, Vult 114 MPH
ALLOWABLE DESIGN WIND SPEED, Vasd 88 MPH
EFFECTIVE PLAN AREA, Ae 260,000 SF
TORNADO DESIGN NOT REQUIRED SINCE VT < 60 MPH
EXPOSURE CATEGORY C
RISK CATEGORY III
INTERNAL PRESSURE COEFFICIENT (GCpi) ±0.18
4. SEISMIC LOADS
MAPPED SPECTRAL RESPONSE ACCELERATION (SHORT PERIOD), SS 0.28
MAPPED SPECTRAL RESPONSE ACCELERATION (1-SEC), S1 0.08
DESIGN SPECTRAL RESPONSE ACCELERATION (SHORT PERIOD), SDS 0.22
DESIGN SPECTRAL RESPONSE ACCELERATION (1-SEC), SD1 0.11
SOIL SITE CLASSIFICATION D
RISK CATEGORY III
SEISMIC IMPORTANCE FACTOR 1.25 1.25
SEISMIC DESIGN CATEGORY B
HIGH PERFORMANCE BUILDINGS
ACT COMPLIANCE STATEMENT
1. IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS
EXEMPT FROM COMPLIANCE BECAUSE THE RENOVATED BUILDING AREA IS NOT
GREATER THAN 5,000 GROSS SQUARE FEET.
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/3
/2
:2
:4
A M
C
U se rs \t re y h a rd e n
\D o cu m e n ts \1
W C
C G ra y so n
H a ll v th a rd e n
B
N
R .r v t
G002
19736
PROJECT CODE: 260-B5260-075 / M25WC153
TAH
EFS
EFS
09/03/2026
IS
S
U E
D F
O R
B
ID
S W
C C
G R
A
YS
O N
H A
LL
E
LE
V
A
TO
R A
N D
LO
A
D
IN
G D
O C
K W
YT
H
EV
IL
LE
, V
IR
G
IN
IA
P R
O
JE
C T
IN
FO
R M
A
TI
O N
A N
D D
A
TA
KEY PLAN
AREA OF WORK
ELEVATOR
LOADING DOCK
PLAN NORTH
ELEVATOR PICTOGRAM
5" x 8" SIGN - MOUNTED 4'-6" TO BOTTOM ABOVE FINISH FLOOR
N o
D at e
R e vi si o n s
DN
UP
UP
UP
DN
UP
FIRE PROTECTION LEGEND
1-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
EXISTING FIRE EXTINGUISHER
FE,E
GENERAL LIFE SAFETY NOTES:
1. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF EXIT LIGHTS, EMERGENCY LIGHTS, AND FIRE
ALARM SYSTEM.
2. REFER TO FIRE PROTECTION DRAWINGS AND SPECIFICATIONS FOR SPRINKLER SYSTEM REQUIREMENTS.
3. ALL PENETRATIONS OF FIRE- OR SMOKE-RATED CONSTRUCTION AND TERMINATION OF RATED
CONSTRUCTION AT STRUCTURE ABOVE, SHALL BE FIRE BLOCKED AND SEALED IN ACCORDANCE WITH
REQUIREMENTS OF THE BUILDING CODE, NFPA, AND UL.
4. FIRE-RATED ASSEMBLIES SHALL BE DESIGNATED ABOVE CEILINGS AND ON THE INSIDE OF ALL CEILING
ACCESS DOORS WHICH PROVIDE ACCESS TO SUCH FIRE RATED ASSEMBLIES BY SIGNAGE HAVING LETTERS
NO SMALLER THAN 3-INCHES IN HEIGHT. SUCH SIGNAGE SHALL INDICATE THE FIRE-RESISTANT RATING OF
THE ASSEMBLY AND TYPE OF ASSEMBLY AS IDENTIFIED IN THE LIFE SAFETY DRAWINGS. SIGNAGE SHALL
BE PROVIDED AT HORIZONTAL INTERVALS OF 8'-0" ON CENTER MAX.
BM
(ABC)
RC
SRC
SMC
BM
RECESSED CABINET
SEMI-RECESSED CABINET
SURFACE MOUNTED
BRACKET MOUNTED
ABC
BC
WC
K
CO2
DRY CHEMICAL
DRY CHEMICAL
WET CHEMICAL
KITCHEN
CARBON DIOXIDE
FIRE EXTINGUISHER MOUNTING: FIRE EXTINGUISHER TYPE:
TYPE
MOUNTING
FIRE EXTINGUISHER LEGEND
ELEV.
EXISTING BUILDING
EXISTING BUILDING
CHILLER
TRANSFORMER
OFFICE
ELEV EQUIP
ELEC
BOILER ROOM
MECH
EQUIPMENT
ROOM
INDUSTRIAL LAB
STAIR
OFFICE
ACR LAB
JAN
CORRIDOR
CLASSROOM
MENS
AUDITORIUM
STAGE
CORR.
CLASSROOM WOMENS
LOBBY
VEST
STAFF MENS
STAFF WOMENS
STORAGE
VEST
STORAGE
STAIR
GRINDING
STORAGE
OFFICE OFFICE
MACHINE MACHINE
DUST COLLECTION
GENERAL
TECHNICAL
OFFICE
VEST
WELDING
LOCKERS
LOADING DOCK
BACK STAGE
CORRIDOR
DRESSING
DRESSING
VEST STORAGE CORR.
VEST
LOBBY
VEST
KITCHEN MEN WOMEN
JAN
FE,E
SCALE: 1/16" = 1'-0"
8' 16'0 32'
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/3
/2
:2
:4
A M
C
U se rs \t re y h a rd e n
\D o cu m e n ts \1
W C
C G ra y so n
H a ll v th a rd e n
B
N
R .r v t
LS101
19736
PROJECT CODE: 260-B5260-075 / M25WC153
TAH
EFS
EFS
09/03/2026
IS
S
U E
D F
O R
B
ID
S W
C C
G R
A
YS
O N
H A
LL
E
LE
V
A
TO
R A
N D
LO
A
D
IN
G D
O C
K W
YT
H
EV
IL
LE
, V
IR
G
IN
IA
FI
R
E P
R O
TE
C
TI
O
N P
LA
N
KEY PLAN
AREA OF WORK
ELEVATOR
LOADING DOCK
PLAN NORTH
PLAN NORTH
SCALE: 1/16" = 1'-0"A401 LS101
1 FIRST FLOOR FIRE PROTECTION PLAN
ORIGINAL BUILDING CODE INFORMATION AND FIRE-RATED PARTITIONS TAKEN FROM
VVKR INCORPORATED DOCUMENTS DATED OCTOBER 11, 1982 AND FROM RRMM
DOCUMENTS DATED JANUARY 8, 2008 (REVISED MARCH 10, 2008).
N o
D at e
R e vi si o
FIRE PROTECTION LEGEND
1-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
EXISTING FIRE EXTINGUISHER
FE,E
GENERAL LIFE SAFETY NOTES:
1. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF EXIT LIGHTS, EMERGENCY LIGHTS, AND FIRE
ALARM SYSTEM.
2. REFER TO FIRE PROTECTION DRAWINGS AND SPECIFICATIONS FOR SPRINKLER SYSTEM REQUIREMENTS.
3. ALL PENETRATIONS OF FIRE- OR SMOKE-RATED CONSTRUCTION AND TERMINATION OF RATED
CONSTRUCTION AT STRUCTURE ABOVE, SHALL BE FIRE BLOCKED AND SEALED IN ACCORDANCE WITH
REQUIREMENTS OF THE BUILDING CODE, NFPA, AND UL.
4. FIRE-RATED ASSEMBLIES SHALL BE DESIGNATED ABOVE CEILINGS AND ON THE INSIDE OF ALL CEILING
ACCESS DOORS WHICH PROVIDE ACCESS TO SUCH FIRE RATED ASSEMBLIES BY SIGNAGE HAVING LETTERS
NO SMALLER THAN 3-INCHES IN HEIGHT. SUCH SIGNAGE SHALL INDICATE THE FIRE-RESISTANT RATING OF
THE ASSEMBLY AND TYPE OF ASSEMBLY AS IDENTIFIED IN THE LIFE SAFETY DRAWINGS. SIGNAGE SHALL
BE PROVIDED AT HORIZONTAL INTERVALS OF 8'-0" ON CENTER MAX.
BM
(ABC)
RC
SRC
SMC
BM
RECESSED CABINET
SEMI-RECESSED CABINET
SURFACE MOUNTED
BRACKET MOUNTED
ABC
BC
WC
K
CO2
DRY CHEMICAL
DRY CHEMICAL
WET CHEMICAL
KITCHEN
CARBON DIOXIDE
FIRE EXTINGUISHER MOUNTING: FIRE EXTINGUISHER TYPE:
TYPE
MOUNTING
FIRE EXTINGUISHER LEGEND
ELEV.
DRAFTING
WORKROOM
DRAFTING
OFFICE
CORRIDOR
DRAFTING
OFFICE OFFICE OFFICE OFFICE
OFFICESTORAGE
MENTAL HEALTH
SERVICES
ACAD. ADMIN
ACAD. ADMIN
OFFICE
OFFICE
STAIR
TLT
PROJ. ROOM
OFFICE
OFFICEOFFICEOFFICE
OFFICE OFFICE
STORAGE
COPY
LOCKERS
VEST. LOBBY
OFFICE
OFFICE
CAREER CENTER
STOR.
OFFICE
STAFF
VEST.
STAIR
STAFF
WOMENS
MENS
STOR.STOR.
ADMIN EDP DATA PROCESS
CLASSROOM
ELECTRICAL ELECTRONICS
ADMIN EDP
JAN.OFFICEOFFICE
ADMIN EDP ADMIN EDP
EXISTING BUILDING
EXISTING BUILDING
ROOF BELOW
ROOF BELOW
AUDITORIUM BELOW
SCALE: 1/16" = 1'-0"
8' 16'0 32'
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/3
/2
:2
:4
A M
C
U se rs \t re y h a rd e n
\D o cu m e n ts \1
W C
C G ra y so n
H a ll v th a rd e n
B
N
R .r v t
LS102
19736
PROJECT CODE: 260-B5260-075 / M25WC153
TAH
EFS
EFS
09/03/2026
IS
S
U E
D F
O R
B
ID
S W
C C
G R
A
YS
O N
H A
LL
E
LE
V
A
TO
R A
N D
LO
A
D
IN
G D
O C
K W
YT
H
EV
IL
LE
, V
IR
G
IN
IA
FI
R
E P
R O
TE
C
TI
O
N P
LA
N
KEY PLAN
AREA OF WORK
ELEVATOR
PLAN NORTH
PLAN NORTH
SCALE: 1/16" = 1'-0"A401 LS102
1 SECOND FLOOR FIRE PROTECTION PLAN
ORIGINAL BUILDING CODE INFORMATION AND FIRE-RATED PARTITIONS TAKEN FROM
VVKR INCORPORATED DOCUMENTS DATED OCTOBER 11, 1982 AND FROM RRMM
DOCUMENTS DATED JANUARY 8, 2008 (REVISED MARCH 10, 2008).
N o
D at e
R e vi si o
OCCURS WHERE ARE INDICATED ON DRAWINGS.#
AD101AD101
AD101AD101
ELEV.
ELEV EQUIP
FE,E
AD101AD101
AD101AD101
ELEV.
FIRST FLOOR
0'-0"
SECOND FLOOR
16'-8"
JOIST BRG
29'-4"
MEZZANINE
9'-0"
PIT
-4'-0"
8"
8"
0"
EXISTING CMU
EXISTING CMU 1
GENERAL DEMOLITION NOTES:
1. ANY DISCREPANCIES BETWEEN ITEMS NOTED FOR DEMOLITION AND ACTUAL FIELD CONDITIONS
ARE TO BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF DEMOLITION.
2. DO NOT REMOVE OR DEMOLISH ANY LOAD-BEARING BUILDING ELEMENTS WITHOUT FIRST
CONTACTING THE ARCHITECT/STRUCTURAL ENGINEER.
3. REMOVE AND/OR CAP OFF ANY MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS
CONTAINED WITHIN CONSTRUCTION SCHEDULED TO BE REMOVED. CAP OFF BEHIND FACE OF
EXISTING WALLS INDICATED TO REMAIN OR BELOW THE FLOOR SLAB. COORDINATE THESE
REQUIREMENTS WITH MECHANICAL, PLUMBING, AND ELECTRICAL REQUIREMENTS. REFER ALSO
TO CUT AND PATCH REQUIREMENTS IN THE PROJECT MANUAL.
4. LEGALLY DISPOSE OF ALL MATERIALS ASSOCIATED WITH SELECTIVE DEMOLITION WORK UNLESS
OTHERWISE NOTED TO BE PROVIDED TO OWNER OR SALVAGED FOR REUSE.
5. COORDINATE ANY REQUIRED TEMPORARY UTILITY OR SERVICE SHUT-OFF WITH OWNER AND
OTHER REQUIREMENTS FOUND IN THE CONTRACT DOCUMENTS.
6. PERFORM DEMOLITION WORK IN SUCH A WAY AS TO MINIMIZE DISTURBANCES WITHIN THE
EXISTING FACILITY.
7. WHERE NEW UTILITIES OR SERVICES ARE RUN ABOVE CEILINGS IN AREAS OF THE EXISTING
FACILITY, REMOVE ONLY AS MUCH EXISTING CEILING SYSTEM AS REQUIRED FOR INSTALLATION.
REINSTALL REMOVED CEILING SYSTEM ONCE ABOVE CEILING WORK IS COMPLETE. REPLACE
CEILING PANELS AND/OR GRID DAMAGED BY SELECTIVE DEMOLITION WORK.
NEW CONC SLAB
OVER 15 MIL VAPOR
BARRIER
EPOXY GROUT #3x3'-0" DOWELS
@ 24 INTO EXST SLAB, TYP
STAGGER W/ OPPOSITE SIDE
3'-0" OR LESS
COMPACTED
#21A/B STONE
MIN, TYP
1'-0"
NOTES:
1. SALVAGE 8" OF EXST VAPOR BARRIER ON EACH SIDE OF TRENCH TO LAP WITH
NEW VAPOR BARRIER.
2. FOR OPENINGS GREATER THAN 3'-0", PROVIDE ADDITIONAL #3@18 EACH WAY
REINFORCING IN NEW SLAB.
3. CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT
28 DAYS.
4. REINFORCEMENT SHALL BE ASTM A615, GRADE 60.
5. INSTALL CONCRETE AND CURE CONCRETE IN ACCORDANCE WITH ACI 301.
6. CONCRETE SHALL NOT BE AIR ENTRAINED.
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/3
/2
:2
:4
A M
C
U se rs \t re y h a rd e n
\D o cu m e n ts \1
W C
C G ra y so n
H a ll v th a rd e n
B
N
R .r v t
AD101
19736
PROJECT CODE: 260-B5260-075 / M25WC153
TAH
EFS
EFS
09/03/2026
IS
S
U E
D F
O R
B
ID
S W
C C
G R
A
YS
O N
H A
LL
E
LE
V
A
TO
R A
N D
LO
A
D
IN
G D
O C
K W
YT
H
EV
IL
LE
, V
IR
G
IN
IA
D
EM
O
LI
TI
O
N F
LO
O
R P
LA
N
DEMOLITION NOTES
1 REMOVE EXISTING ELEVATOR IN ITS ENTIRETY. INCLUDING THE PISTON AND RAILS.
2 REMOVE EXISTING HALL DOOR. HALL FRAME TO REMAIN - PREPARE TO RECEIVE
NEW STAINLESS STEEL WRAP.
3 REMOVE PORTION OF EXISTING SLAB AS REQUIRED FOR NEW SUMP PIT. REFER TO
DETAIL 5A401.
4 REMOVE AND RELOCATE EXISTING FIRE EXTINGUISHER PER NEW WORK PLANS.
5 EXISTING PIT LADDER TO REMAIN.
6 REMOVE PORTION OF EXISTING SLAB AS REQUIRED FOR NEW PLUMBING. REFER
TO DETAIL 5AD101.
SCALE: 3/8" = 1'-0"
6" 1'0 2'
KEY PLAN
AREA OF WORK
ELEVATOR
PLAN NORTH
SCALE: 1/4" = 1'-0"A401 AD101
1 PIT DEMOLTION PLAN
SCALE: 1/4" = 1'-0"A401 AD101
2 FIRST FLOOR DEMOLITION PLAN
SCALE: 1/4" = 1'-0"A401 AD101
3 SECOND FLOOR DEMOLITION PLAN
SCALE: 3/8" = 1'-0"AD101 AD101
4 ELEVATOR SECTION DEMOLITION
SCALE: 1/4" = 1'-0"
2' 4'0 8'
SCALE: 3/4" = 1'-0"AD101 AD101
5 SLAB REPLACEMENT SECTION DETAIL
NOT TO SCALE
PLAN NORTH
PLAN NORTH
PLAN NORTH
N o
D at e
R e vi si o
UP
OCCURS WHERE ARE INDICATED ON DRAWINGS.#
ELEV.
CHILLER
TRANSFORMER
OFFICE
ELEV EQUIP
ELECBOILER ROOM
MECH
EQUIPMENT
ROOM
INDUSTRIAL LAB
STAIR
OFFICE
ACR LAB
JAN
CORRIDOR
CLASSROOM
VEST
GRINDING
STORAGE
OFFICE OFFICE
MACHINE MACHINE
DUST COLLECTION
GENERAL
TECHNICAL
OFFICE
VEST
WELDING
LOCKERS
LOADING DOCK
CORR.
0"
0"
0"
A101 A401
2 HR FIRE RATED
ELEVATOR SHAFT
FE
ELEV.
DRAFTING
WORKROOM
DRAFTING
OFFICE
CORRIDOR
DRAFTING
OFFICE
TLT
PROJ. ROOM
OFFICE
OFFICE
LOCKERS
ADMIN EDP
JAN.OFFICEOFFICE
A101 A401
2 HR FIRE RATED
ELEVATOR SHAFT
SE
C
TI
O
N
M
IN
M
A X
* 54 MAX FOR EXISTING
M
IN
-1
/2 M
IN 2
-1
/2 M
IN
C 2 M
IN
M
IN
407.2.3.2 CAR IDENTIFICATION407.2.3.1 FLOOR DESIGNATION407.2.2.2(B) ELEVATOR VISIBLE SIGNALS SIZE OF SIGNALS
407.2.1.1 HEIGHT OF ELEVATOR CALL BUTTONS
407.2.2.2(A) ELEVATOR VISIBLE SIGNALS HEIGHT OF SIGNALS
SCALE: 1/8" = 1'-0"
4' 8'0 16'
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/3
/2
:2
:4
A M
C
U se rs \t re y h a rd e n
\D o cu m e n ts \1
W C
C G ra y so n
H a ll v th a rd e n
B
N
R .r v t
A101
19736
PROJECT CODE: 260-B5260-075 / M25WC153
TAH
EFS
EFS
09/03/2026
IS
S
U E
D F
O R
B
ID
S W
C C
G R
A
YS
O N
H A
LL
E
LE
V
A
TO
R A
N D
LO
A
D
IN
G D
O C
K W
YT
H
EV
IL
LE
, V
IR
G
IN
IA
N
EW
W O
R K
F
LO
O R
P
LA
N
CONSTRUCTION NOTES
1 REFER TO STRUCTURAL DRAWINGS FOR NEW EDGE OF LOADING DOCK LEVELER.
2 PAINT ENTIRETY OF GATE.
3 CONDENSING UNIT - REFER TO MECHANICAL DRAWINGS. REMOVE EXISTING LANDSCAPING
AS REQUIRED FOR UNIT INSTALLATION. CONTRACTOR TO RESTORE THE LANDSCAPING IN
THE DISTURBED AREA WITH MULCH TO MATCH ADJACENT LANDSCAPING.
KEY PLAN
AREA OF WORK
ELEVATOR
LOADING DOCK
PLAN NORTH
PLAN NORTH
SCALE: 1/8" = 1'-0"A401 A101
1 FIRST FLOOR PLAN
SCALE: 1/8" = 1'-0"A401 A101
2 SECOND FLOOR PLAN
PLAN NORTH
ANSI 117.1 SECTION 407
NOT TO SCALE
N o
D at e
R e vi si o
3" CLR, TYP
TYP
8"
C
LR
, T
YP
0"
(X 2'-0")
2'-0"2
0"
TYP
6"
TYP
8"
NOTES:
1. CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS.
2. CONCRETE SHALL NOT BE AIR-ENTRAINED.
3. REINFORCEMENT SHALL BE ASTM A615, GRADE 60.
4. INSTALL CONCRETE AND CORE CONCRETE IN ACCORDANCE WITH ACI 301.
'-0
± 6"
2" CLR
C
LR
2" CLR
C
LR
GALVANIZED 19-W-4
GRATING W/ 1 1/4" x 3/16"
BEARING BARS#4 CONT
3 - #4 CONT, TYP
#4@12, TYP
ALL 4 SIDES
WATERSTOP, TYP
4 - #4 EW, T&B
#4@12 #4@12
A401A401
A401
A401
A
B
C
D
A401 A401
ELEVATOR PICTOGRAM -
SEE SHEET G002
ELEV.ELEV EQUIP
FE
RELOCATED FIRE
EXTINGUISHER, MOUNT
TOP AT 48" AFF
A401A401
ELEVATOR PICTOGRAM -
SEE SHEET G002
ELEV.
A401A401
NEW CONCRETE
SUMP PIT & GRATING
EXISTING PIT LADDER
TO REMAIN
8" 2'-0"
0" 8"
FIRST FLOOR
0'-0"
SECOND FLOOR
16'-8"
JOIST BRG
29'-4"
MEZZANINE
9'-0"
PIT
-4'-0"
8"
8"
0"
NEW SST HALL DOOR &
SST WRAPPED EXISTING
FRAME
EXISTING PIT LADDER
TO REMAIN
A401 A401
NEW CONCRETE
SUMP PIT & GRATING
NEW PISTON &
GUIDE RAILS
NEW ELEVATOR
REFER TO SPECIFICATIONS FOR
ELEVATOR REQUIREMENTS
NEW SST HALL DOOR &
SST WRAPPED EXISTING
FRAME
EXISTING CMUEXISTING CMU
INFILL FLUTES OF
METAL ROOF DECK
WITH MINERAL WOOL
AT TOP OF ALL WALLS
SPRINKLER PIPING 1
5"
M
IN
8"
M A
X
DOOR
CONTROL PANEL
SST
SST RAIL
7'-10" ± VIF
PLAS LAMINATE
PANELS, TYP
6"
SST BASE
0"
EQ EQ EQ
SST RAIL
PLAS LAMINATE
PANELS, TYP
SST BASE
6"
5'-5 1/2" ± VIF
EQ EQ
SST RAIL
6"
SST BASE
PLAS LAMINATE
PANELS, TYP
EXISTING PIT LADDER
TO REMAIN
ELEV.
EXISTING CMU
EXISTING CMU
5'-5 1/2" ± VIF
V
IF
CLR OPENING
4'-0"
0"
7'-3"
2" EQ 2" EQ 2"
2"
EQ
2"
EQ
2"
POLYCARBONATE
LIGHT COVER, TYP
BLACK PANEL
TRIM, TYP
5'-5 1/2" ± VIF
V
IF
SCALE: 1/4" = 1'-0"
2' 4'0 8'
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/3
/2
:2
:4
A M
C
U se rs \t re y h a rd e n
\D o cu m e n ts \1
W C
C G ra y so n
H a ll v th a rd e n
B
N
R .r v t
A401
19736
PROJECT CODE: 260-B5260-075 / M25WC153
TAH
EFS
EFS
09/03/2026
IS
S
U E
D F
O R
B
ID
S W
C C
G R
A
YS
O N
H A
LL
E
LE
V
A
TO
R A
N D
LO
A
D
IN
G D
O C
K W
YT
H
EV
IL
LE
, V
IR
G
IN
IA
EN
LA
R G
ED
P
LA
N
S A
N D
IN
TE
R
IO
R E
LE
V
A
TI
O N
S
KEY PLAN
AREA OF WORK
ELEVATOR
PLAN NORTH
SCALE: 3/4" = 1'-0"A401 A401
5 SUMP PIT DETAIL
SCALE: 1/4" = 1'-0"A101 A401
2 FIRST FLOOR NEW WORK PLAN
SCALE: 1/4" = 1'-0"A101 A401
3 SECOND FLOOR NEW WORK PLAN
SCALE: 1/4" = 1'-0"A401 A401
1 PIT NEW WORK PLAN
SCALE: 3/8" = 1'-0"A401 A401
4 ELEVATOR SECTION
SCALE: 3/8" = 1'-0"A401 A401
A ELEVATOR ELEVATION
SCALE: 3/8" = 1'-0"A401 A401
B ELEVATOR ELEVATION
SCALE: 3/8" = 1'-0"A401 A401
C ELEVATOR ELEVATION
SCALE: 3/8" = 1'-0"A401 A401
D ELEVATOR ELEVATION
SCALE: 1/2" = 1'-0"A401 A401
6 ELEVATOR PLAN ENLARGED
SCALE: 3/8" = 1'-0"
6" 1'0 2'
SCALE: 1/2" = 1'-0"
1' 2'0 4'
SCALE: 3/4" = 1'-0"
8" 1'-4"0 2'-8"
SCALE: 3/8" = 1'-0"A401 A401
7 REFLECTED CEILING PLAN
PLAN NORTH
PLAN NORTH
PLAN NORTH
PLAN NORTH
PLAN NORTH
N o
D at e
R e vi si o
2'
-0
2'
-0
40'-0" ±
/4
4"
0" 8"
1"
7'-0"15'-1 3/4" ±
FACE OF WALL
INTEGRAL RAMP 7" HIGH
LOW DOCK EDGE OF DOCK LEVELER ±5"
WORKING RANGE (+2" TO 12" ABOVE
CURRENT DOCK HEIGHT)
3"
2"
7"
S100S100
S100S100
S100S100
6"
EXST GUARDRAIL
POST
EXST GATEEXST GATE
HINGE, TYP
EXST GUARDRAIL
POST
8" 7"
5"
7"
RELOCATE EXST
GATE WHEEL
NOTE:
PAINT EXISTING GATE AFTER MODIFICATIONS ARE COMPLETE.
PAINT SHALL MATCH EXISTING COLOR OF GATE AND GUARDRAILS.
EDGE OF DOCK
LEVELER RAMP
S100 S100
S100 S100
12'-1 1/2" ±
EXST GATE LATCH
8" 8"
EXST GATE WHEEL
TO BE RELOCATED
EXST GUARDRAIL
POST
DEMO & SALVAGE BOT
RAIL OF EXST GATE
DEMO EXST GATE VERTICAL UP TO
BOT OF SECOND HORIZONTAL RAIL
EXST GATE
EXST GATE
HINGE, TYP
EXST GUARDRAIL
POST
EXST GATE LATCH
8"
EXST GATE
END VERTICAL
EXST GATE HINGE
EXST GUARDRAIL
POST
SALVAGED GATE
BOT RAIL
3/16
EXST GATE
END VERTICAL
EXST GUARDRAIL
POST
SALVAGED GATE
BOT RAIL
3/16
TYP
TYP
8" 7"
3/16
SALVAGED GATE
BOT RAIL
RELOCATED GATE
WHEEL
GATE SWING
RADIUS
EDGE OF DOCK
LEVELER INTEGRAL
RAMP 7" HIGH
GATE WHEEL SHALL PASS BY RAMP
WITHOUT RUNNING OVER RAMP. ADJUST
GATE WHEEL ON NEW GATE EXTENSION
AS REQUIRED TO MISS EDGE OF DOCK
LEVELER INTEGRAL RAMP
EDGE OF DOCK
LEVELER
7'-0"
EXST GATE
EDGE OF DOCK
LEVELER
DOCK BUMPER
EXST 1'-0" CONC
DOCK WALL
EXST PAVEMENT
EDGE OF DOCK LEVELER
INTEGRAL RAMP
7"
EXST 5"± SLAB
GALV 5/8" DIA
EXPANSION ANCHORS
W/ 4" EMBEDMENT, TYP
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/2
/2
:0
:4
P
M R
P ro je ct s\
W y th e v il le
C o m m u n it y
C o ll e g e
G ra y so n H a ll\
E N
G
IN
E E
R
IN
G \S
T R
U C
T \D ra w in g s\ D
W G
\1
-W
C C
G R
A Y
S O
N H
A
LL
-S T
R U
C T
U R
A L v
.r v t
S100
19736
PROJECT CODE: 260-B5260-075 / M25WC153
MLT
KAA
KAA
09/03/2026
IS
S
U E
D F
O R
B
ID
S W
C C
G R
A
YS
O N
H A
LL
E
LE
V
A
TO
R A
N D
LO
A
D
IN
G D
O C
K W
YT
H
EV
IL
LE
, V
IR
G
IN
IA
LO
A
D
IN
G D
O C
K P
LA
N
SCALE: 1/4" = 1'-0"
2' 4'0 8'
SCALE: 1/4" = 1'-0"S100
1 FOUNDATION PLAN-DOCK LEVELER
KEY PLAN
AREA OF WORK
LOADING DOCK
SCALE: 3/4" = 1'-0"S100 S100
4 NEW SECTION
SCALE: 3/4" = 1'-0"S100 S100
3 DEMO SECTION
SCALE: 3/4" = 1'-0"
8" 1'-4"0 2'-8"
SCALE: 1 1/2" = 1'-0"S100 S100
5 DETAIL
SCALE: 1 1/2" = 1'-0"S100 S100
6 DETAIL
SCALE: 1 1/2" = 1'-0"
4" 8"0 1'-4"
SCALE: 1/4" = 1'-0"S100
2 GATE SWING PLAN
PLAN NORTH
PLAN NORTH
SCALE: 3/4" = 1'-0"S100 S100
7 SECTION
PLAN NORTH
N o
D at e
R e vi si o
Level 1
0' - 0"
ROOF
10' - 0"
FIRST FLOOR
0'-0"
ROOF
31'-5"
SECOND FLOOR
16'-8"
JOIST BRG
29'-4"
UPPER FIRST FLOOR
1'-4"
MEZZANINE
9'-0"
PIT
-4'-0"
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/3
/2
:5
:3
A
M C
U se rs
\s te v e n th o m a s\ D o cu m e n ts
\1
-G ra y so n e le v a to r_ p lu m b
-F P st h o m a s@ t-l.
co m .r v t
FP001
19736
PROJECT CODE: 260-B5260-075 / M25WC153
RTB
RTB
SGT
09/03/2026
IS
S
U E
D F
O R
B
ID
S W
C C
G R
A
YS
O N
H A
LL
E
LE
V
A
TO
R A
N D
LO
A
D
IN
G D
O C
K W
YT
H
EV
IL
LE
, V
IR
G
IN
IA
FI
R
E P
R O
TE
C
TI
O
N N
O
TE
S, S
P
EC
IF
IC
A
TI
O N
S
LE
G
EN
D
FIRE-STOPPING
USING UL FIRE STOP SYSTEMS.
PROVIDE FIRE STOPPING OF ALL PIPE, FITTINGS, CONDUIT, DUCTWORK THRU
RATED PARTITIONS. ALL PIPE AND CONDUIT SHALL BE SLEEVED AND CAULKED
1.
FIRE SUPPRESSION SYSTEM
REFERENCES; NFPA 13 - INSTALLATION OF SPRINKLER SYSTEMS1.
ADD NEW SPRINKLER HEADS AND PREACTION SYSTEM AS INDICATED ON PLANS. ALL WORK SHALL BE PERFORMED2.
SUBMITTALS; INDICATE LAYOUT OF SPRINKLER LOCATIONS COORDINATED WITH CEILING3.
INSTALLATION. INDICATE DETAILED PIPE LAYOUT, HANGERS AND SUPPORTS, SPRINKLERS,
COMPONENTS AND ACCESSORIES. INDICATE SYSTEM CONTROL. PROVIDE PRODUCT DATA
OF SPRINKLERS, VALVES AND SPECIALTIES. SUBMIT DESIGN CALCULATIONS FOR REVIEW
AND APPROVAL.
IN ACCORDANCE WITH NFPA 13 REQUIREMENTS.
PRE-ACTION SPRINKLER SYSTEM4.
A. FURNISH AND INSTALL A FACTORY WIRED AND FACTORY TESTED SELF CONTAINED DUAL INTERLOCK
PREACTION SYSTEM CONTAINING ALL REQUIRED MECHANICAL AND ELECTRICAL COMPONENTS.
1) STANDARD: FM CLASS NUMBERS 1011/1012/1013 0 DELUGE AND PREACTION SYSTEMS.
2) ENCLOSURE:
a) TWO STEEL ENCLOSURES FACTORY ASSEMBLED TOGETHER: ONE ABOVE THE OTHER.
b) LOWER ENCLOSURE: 14 GAGE STEEL WITH CONTINUOUS WELDED SEAMS
c) UPPER ENCLOSURE: 12 GAGE STEEL WITH CONTINUOUS WELDED SEAMS
d) BOTH ENCLOSURES SHALL BE FINISHED IN POWDER COATED RED PAINT
e) BOTH ENCLOSURES SHALL BE EQUIPPED WITH LOCKABLE ACCESS DOORS
f) KEY LOCKS FOR UPPER AND LOWER ENCLOSURE DOORS SHALL BE EQUIPPED WITH DIFFERENT KEYS
g) AN ACCESS DOOR FOR MANUAL RELEASE HANDLE SHALL BE PROVIDED THAT IS SEPARATE FROM
ENCLOSURE DOORS. THE MANUAL RELEASE DOOR SHALL NOT REQUIRE A KEY.
h) ALL DOORS SHALL BE EQUIPPED WITH FULL PIANO HINGE AND OIL RESISTANT GASKETS.
B. FIRE PROTECTION VALVE:
1) GENERAL REQUIREMENTS
a) THE FIRE PROTECTION VALVE SHALL BE VICTAULIC MODEL FIRELOCK NXT SERIES 769 OR AN
APPROVED EQUAL. THE VALVE SHALL BE A LOW-DIFFERENTIAL, LATCHED CLAPPER VALVE THAT USES
THE SUPPLY WATER PRESSURE FROM UPSTREAM OF THE MAIN CONTROL VALVE TO HOLD THE
CLAPPER SHUT. WHEN THE WATER PRESSURE IN THE DIAPHRAGM CHAMBER IS RELEASED, THE LATCH
IS RETRACTED AND THE VALVE ACTUATES.
b) THE VALVE SHALL BE SELF RESETTING AND NO DISASSEMBLY OR COVER REMOVAL SHALL BE REQUIRED
FOR RESET.
c) THE VALVE SHALL BE RATED FOR NO LESS THAN 300 PSIG WATER WORKING PRESSURE, AND FACTORY
HYDROSTATICALLY TESTED TO A MINIMUM OF 600 PSIG.
d) MINIMUM REQUIRED SUPERVISORY GAS PRESSURE SHALL BE 13 PSIG.
e) NO SEPERATE CHECK VALVE SHALL BE REQUIRED.
f) VALVE SHALL BE FACTORY ASSEMBLED TO AN INLET TEE SECURED TO THE BOTTOM OF THE LOWER
ENCLOSURE.
g) THE FULL TRIM FOR THE PREACTION VALVE SHALL BE FACTORY ASSEMBLED. NO FIELD MODIFICATIONS
OF THE VALVE TRIM SHALL BE PERMITTED.
2) STANDARDS
a) UL 260 - DRY PIPE AND DELUGE VALVES FOR FIRE PROTECTION SERVICE
b) FACTORY MUTUAL (FM) CLASS NUMBER 1020 - AUTOMATIC WATER CONTROL VALVES
3) OPERATION
a) THE VALVE SHALL OPERATE AS A DOUBLE INTERLOCK PREACTION VALVE WITH ELECTRIC RELEASE.
WHEN THE ELECTRIC SOLENOID IS OPERATED BY THE CONTROL PANEL AND THE SUPERVISORY GAS IS
EXHAUSTED BY THE OPERATION OF AN AUTOMATIC SPRINKLER HEAD, THE WATER IN THE DIAPHRAGM
CHAMBER SHALL BE RELEASED AND THE VALVE SHALL OPEN.
C. COMPRESSOR
1) FACTORY ASSEMBLED INTO LOWER ENCLOSURE, WIRED AND ATTACHED TO PREACTION VALVE.
2) COMPRESSOR SHALL BE SIZED TO RESTORE NORMAL AIR PRESSURE IN THE PREACTION SYSTEM PIPING IN
30 MINUTES.
3) COMPRESSOR SHALL BE OF THE OIL-LESS PISTON TYPE, EQUIPPED WITH A PRESSURE SWITCH AND A
BUBBLE TIGHT CHECK VALVE.
4) THE COMPRESSOR SHALL BE 120VAC, 60 Hz, 1 PHASE
D. CONTROL PANEL, INTEGRATED AND FACTORY WIRED, AND INTEGRAL WITH PREACTION SYSTEM CABINET
1) FACTORY ASSEMBLED INTO UPPER ENCLOSURE
2) FACTORY WIRED TO RELEASE SOLENOID IN LOWER ENCLOSURE
3) VISIBLE THROUGH WINDOW IN UPPER ENCLOSURE DOOR
4) LISTED AND APPROVED FOR PREACTION RELEASE SERVICE
E. SYSTEM REQUIREMENTS
1) CONTROL PANEL SHALL CONSIST OF A PRINTED CIRCUIT BOARD WITH MAIN SYSTEM MICROPROCESSOR, REAL TIME CLOCK, HISTORY BUFFER, AN INTEGRAL DISPLAY/CONTROL ASSEMBLY, WATCHDOG TIMER, ONE USB DEVICE PORT, TWO RS-232 SERIAL PORTS, TERMINATION FOR FIELD CIRCUITS.
2) FIELD CIRCUITS SHALL INCLUDE: ONE SIGNALING LINE CIRCUIT (SLC) THAT SERVES AS THE HARDWARE
AND SOFTWARE INTERFACE BETWEEN THE INTELLIGENT INITIATING AND CONTROL DEVICES AND THE
CONTROL PANEL. THE SLC SHALL BE CAPABLE OF COMMUNICATING WITH UP TO 255 FIRE DETECTORS, MONITOR MODULES, AND CONTROL DEVICES; TWO NOTIFICATION APPLIANCE CIRCUITS (NACs)
INDEPENDENTLY PROGRAMMABLE AND CONFIGURABLE FOR EITHER CLASS A OR B OPERATION. IT SHALL
NOT BE NECESSARY TO USE EXTERNAL SYNCHRONIZATION MODULES TO SYNCHRONIZE THE AUDIBLE AND
VISUAL NOTIFICATION SIGNALS CREATED BY ANY NAC; TWO RELEASING CIRCUITS; TWO COMBINATION
NAC/RELEASING CIRCUITS; THREE PROGRAMMABLE VOLT FREE RELAY CONTACTS; ONE VOLT FREE
TROUBLE RELAY CONTACT; ONE RS-485 COMMUNICATION CIRCUIT; ONE CIRCUIT FOR CONNECTION OF
SECONDARY BATTERY, PROVIDING FOR CHANGEOVER TO SECONDARY POWER UPON LOSS OF PRIMARY
POWER AND CHARGING THE BATTERY WHEN PRIMARY POWER IS PRESENT.
F. THE PREACTION SYSTEM SHALL INCLUDE A PRIMARY POWER SUPPLY/CHARGER ASSEMBLY CONSISTING OF
AN AC TO DC SWITCHING POWER UNIT. IT SHALL BE FACTORY CONFIGURED TO ACCEPT 120VAC INPUT
VOLTAGE, AND SHALL PROVIDE 5.4 A AT 24 VDC OF FILTERED AND REGULATED POWER TO OPERATE THE
SYSTEM AND CHARGE THE SYSTEM'S STANDBY BATTERIES. TWO USER-CONFIGURABLE AUXILIARY POWER
CIRCUITS SHALL BE PROVIDED ON THE PCB TO POWER PERIPHERAL DEVICES. THE AUXILIARY POWER
CIRCUITS SHALL BE SOFTWARE PROGRAMMABLE FOR EITHER CONTINUOUS OR INTERRUPTIBLE POWER
OUTPUT AND SHALL BE RATED FOR 1.0 AMPS AT 24 VDC. IT SHALL NOT BE NECESSARY TO SET JUMPERS
OR DIP SWITCHES ON THE PCB TO MAKE THESE OUTPUTS CONTINUOUS OR INTERRUPTIBLE.
OPERATOR SWITCHES AND INTERFACE SHALL INCLUDE: EVENT ACKNOWLEDGEMENT SWITCH; ALARM
SILENCE SWITCH; SCROLL SWITCH; SYSTEM RESET SWITCH; SIX STATUS LEDs - POWER ON, ALARM, PRE-
ALARM, TROUBLE, SUPERVISORY, SILENCE; 12-KEY NUMERICAL KEYPAD WITH BACKSPACE AND ENTER
KEYS; 80 CHARACTER BACKLIT LIQUID CRYSTAL DISPLAY (LCD).
G. PROGRAMMING:
1) THE CONTROL PANEL SHALL BE PROGRAMMABLE AND CONFIGURABLE IN THE FIELD WITHOUT
PROGRAMMING PROM CHIPS OR REPLACEMENT OF MEMORY CHIPS
2) PROGRAMMING SHALL ALLOW ANY INPUT TO ACTIVATE ANY OUTPUT OR GROUP OF OUTPUTS. SYSTEMS
WITH LIMITED PROGRAMMING CAPABILITY OR COMPLEX HARDWARE PROGRAMMING ARE NOT
ALLOWED.
H. COMMUNICATION
1) THE CONTROL PANEL SHALL COMMUNICATE WITH ALL INITIATING DEVICES VIA A DIGITAL DATA
PROTOCOL, TRANSMITTED OVER A TWO-WIRE SIGNALING LINE CIRCUIT.
2) EACH POINT ON THE SLC SHALL HAVE A UNIQUE ADDRESS, PERMITTING POINT IDENTIFICATION OF FIRE
LOCATION AND DETECTOR DEFAULTS.
3) THE COMMUNICATION PROTOCOL USED BY THE CONTROL PANEL OVER THE SLC SHALL PROVIDE
COMPLETE SUPERVISION OF WIRING AND DETECTOR STATUS.
I. CONTACTS: THE FOLLOWING DRY CONTACTS SHALL BE PROVIDED FOR SIGNALING THE BUILDING FIRE
ALARM SYSTEM
1) ALARM: CONTACT SHALL OPERATE ON ANY FIRE ALARM SIGNAL PROCESSED BY THE CONTROL PANEL
2) TROUBLE: CONTACT SHALL OPERATE ON ANY FAULT REPORTED BY THE CONTROL PANEL
3) SUPERVISORY: CONTACT SHALL OPERATE ON ANY SUPERVISORY SIGNAL PROCESSED BY THE CONTROL
PANEL.
J. ADDRESSABLE MONITOR MODULE
1) ADDRESSABLE MONITOR MODULES SHALL BE FACTORY ASSEMBLED INTO THE UPPER ENCLOSURE AND
FACTORY WIRED TO THE FOLLOWING CONNECTION POINTS: LOW AIR SENSOR SWITCH, TAMPER SWITCH, WATERFLOW SENSOR SWITCH
K. ADDRESSABLE OUTPUT MODULE
1) ADDRESSABLE OUTPUT MODULE SHALL BE FACTORY ASSEMBLED INTO UPPER ENCLOSURE AND FACTORY
WIRED TO VALVE RELEASING SOLENOID IN LOWER ENCLOSURE.
L. OTHER REQUIREMENTS:
1) THE PREACTION SYSTEM SHALL ALSO HAVE THREE PRESSURE GAGES FACTORY ASSEMBLED AND VISIBLE
THROUGH CUTOUTS IN LOWER ENCLOSURE WITHOUT OPENING LOWER ENCLOSURE DOOR: SYSTEM AIR
PRESSURE, WATER SUPPLY PRESSURE, VALVE LINE PRESSURE; MANUAL RELEASE HANDLE BEHIND
SEPARATE NON-LOCKABLE DOOR IN LOWER ENCLOSURE; PRINTED INSTRUCTIONS IN UPPER ENCLOSURE;
KNOCKOUTS PROVIDED IN UPPER ENCLOSURE FOR ATTACHMENT OF EXTERNAL ELECTRICAL CONDUIT;
SPACE FOR REQUIRED SPRINKLER HEADS AND SPRINKLER WRENCH IN UPPER ENCLOSURE; ALL FACTORY
WIRING IN LOWER ENCLOSURE - NO FIELD WIRING IS PERMITTED; INLET FOR WATER SUPPLY ON TOP OF
LOWER ENCLOSURE, WITH OPTIONAL INLETS ON THE LEFT AND RIGHT SIDES OF THE LOWER ENCLOSURE;
OUTLET FOR WATER TO SPRINKLERS ON TOP OF LOWER ENCLOSURE; 120VAC 60 Hz SINGLE PHASE
CONNECTION POINT IN THE UPPER CHAMBER FOR THE CONTROL PANEL AND THE COMPRESSOR.
JUMPERS MAY BE REMOVED TO SEPARATE 120VAC CONNECTIONS FOR CONTROL PANEL AND
COMPRESSOR.
2) THE PREACTION ASSEMBLY SHALL BE FM APPROVED AND MARKED WITH FM APPROVAL ON THE INSIDE
OF THE UPPER ENCLOSURE.
M. DETECTORS, SENSORS, ETC.
COORDINATE WITH ELECTRICAL DRAWINGS FOR THE INSTALLATION OF THE DETECTORS, SENSORS, ETC
THAT ARE REQUIRED FOR PREACTION SYSTEM.
PIPE HANGER DETAIL
NOT TO SCALE
HANGER ROD
SPRINKLER PIPING
N o
D at e
R e vi si o n s
FIRE PROTECTION LEGEND
SPRINKLER PIPE DOWN
SPRINKLER PIPE UP
UPRIGHT SPRINKLER HEAD
SIDEWALL SPRINKLER HEAD
SIDEWALL SPRINKLER
HEAD
UPRIGHT SPRINKLER
HEAD
SCALE: 1/4" = 1'-0"FP101 FP001
1 Elevator Section
09/03/2026
PROVIDE A SIDEWALL SPRINKLER HEAD A MAX OF 2' ABOVE ELEVATOR PIT
FLOOR. THE SIDEWALL SPRINKLER HEAD SHALL BE STANDARD RESPONSE
VIKING MODEL VK104 OR EQUAL WITH A K-FACTOR OF 5.6 AND 175 DEGREE
TEMPERATURE RATING. THE ELEVATOR HAS TO BE RECALLED, PARKED AND
THE POWER TRIPPED OFF BEFORE THE SPRINKLER CAN BE RELEASED
PROVIDE A STANDARD RESPONSE
UPRIGHT HEAD EQUAL TO
VIKING MODEL 1001 OR EQUAL
WITH A K FACTOR OF 5.6 AND
175 DEGREE TEMPERATURE
RATING. ALL WORK SHALL
COMPLY WITH NFPA 13.
PREACTION SPRINKLER SYSTEM CONTROL PANEL -
REFER TO ELECTRICAL DRAWINGS/SPECIFICATIONS
FOR ALARMS,DETECTORS
OFFICE
ELEV.
BOILER ROOM
ELEC
LOCKERS
CORRIDOR
ELEV EQUIP
2" FPW ELEV.
JAN
EXISTING SPRINKLER RISER
EXISTING 6"
SPRINKLER MAIN
NEW 2" SPRINKLER
PIPING FROM MAIN
TO PREACTION SYSTEM
2" FPW
2" FPW
2" FPW
2" FPW
2" FPW
2" FPW
2" SPRINKLER
LINE UP TO
SECOND FLOOR
FP001FP101
DRAFTING
WORKROOM
ELEV.
PROVIDE A STANDARD RESPONSE
UPRIGHT HEAD EQUAL TO VIKING
MODEL 1001 OR EQUAL WITH A
K FACTOR OF 5.6 AND 175 DEGREE
TEMPERATURE RATING. ALL WORK
SHALL COMPLY NFPA 13. ELEVATOR
HAS TO BE RECALLED, PARKED AND
POWER TRIPPED OFF BEFORE THE
SPRINKLER CAN BE RELEASED
OFFICE
DRAFTING
2" SPRINKLER
LINE FROM
BELOW
FP001FP101
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/3
/2
:5
:3
A
M C
U se rs
\s te v e n th o m a s\ D o cu m e n ts
\1
-G ra y so n e le v a to r_ p lu m b
-F P st h o m a s@ t-l.
co m .r v t
FP101
19736
PROJECT CODE: 260-B5260-075 / M25WC153
RTB
RTB
SGT
09/03/2026
IS
S
U E
D F
O R
B
ID
S W
C C
G R
A
YS
O N
H A
LL
E
LE
V
A
TO
R A
N D
LO
A
D
IN
G D
O C
K W
YT
H
EV
IL
LE
, V
IR
G
IN
IA
1S T/
2N D
F
LO
O R
FI
R E
P R
O
TE
C
TI
O N
SCALE: 1/4" = 1'-0"FP001 FP101
1 FIRST FLOOR - FIRE PROTECTION
SCALE: 1/4" = 1'-0"FP001 FP101
2 SECOND FLOOR - FIRE PROTECTION
SCALE: 1/4" = 1'-0"
2' 4'0 8'
KEY PLAN
AREA OF WORK
ELEVATOR
PLAN NORTH
LIFE SAFETY LEGEND
2-HR FIRE BARRIER
1-HR FIRE BARRIER
PLAN NORTH
PLAN NORTH
NOTE: DURING CONSTRUCTION, PROVIDE A FIRE WATCH
WHILE THE SPRINKLER SYSTEM IS OFFLINE TO INSTALL
PREACTION SYSTEM.
SPRINKLER RISER DIAGRAM
NOT TO SCALE
EXISTING SPRINKLER
RISER IN MECHANICAL
EQUIPMENT ROOM
EXISTING 6" SPRINKLER MAIN
CONNECT NEW 2" WATER LINE
TO NEW PREACTION SPRINKLER
SYSTEM
NEW PREACTION
SPRINKLER SYSTEM
NOTE:
1. THE WORK SHALL MEET THE REQUIREMENTS OF THE 2021 VIRGINIA EXISTING
BUILDING CODE (VEBC), THE 2021 VIRGINIA CONSTRUCTION CODE (VCC)
CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION, THE 2021 INTERNATIONAL
FIRE CODE CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION.
2. WHERE CEILINGS ARE REMOVED DURING CONSTRUCTION, SPRINKLER HEADS
SHALL BE CHANGED TO UPRIGHT HEADS TO KEEP THE SYSTEM OPERATIONAL AS
MUCH AS POSSIBLE. ALL SPRINKLER HEADS REMOVED FROM THE SPRINKLER
PIPING SHALL BE REPLACED WITH SPRINKLER HEADS OF THE SAME TYPE, SAME
TEMPERATURE RATING AND K FACTOR AS THE ORIGINAL SPRINKLER HEAD.
N o
D at e
R e vi si o n
PLUMBING NOTES (Read notes and remove what doesn’t apply for each project)
1. GENERAL:
1. THE PLUMBING DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO SHOW THE GENERAL ROUTING OF PLUMBING SYSTEMS. DO NOT SCALE THE DRAWINGS FOR EXACT LOCATIONS.
VERIFY AND INSTALL THE PLUMBING FIXTURES AT THE LOCATIONS SHOWN ON THE ARCHITECTURAL DRAWINGS. THE CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO AVOID
CONFLICTS WITH STRUCTURE, DUCTWORK, ETC. AND PROVIDE OFFSETS AND ADJUSTMENTS AT NO ADDITIONAL COST TO THE OWNER.
2. THE CONTRACTOR SHALL PERFORM AND INSTALL ALL WORK ACCORDING TO THE PLUMBING CODES LISTED ON THE COVER SHEET AND ANY ADDITIONAL STATE AND LOCAL CODES AS
REQUIRED.
3. THE CONTRACTOR SHALL FURNISH ALL THE LABOR, MATERIALS, AND EQUIPMENT NECESSARY TO PROVIDE A COMPLETE PLUMBING SYSTEM AS INDICATED IN THE CONTRACT DOCUMENTS
AND IN THESE DRAWINGS.
4. THE CONTRACTOR SHALL PAY ALL ASSOCIATED COSTS FOR TAP FEES, PERMITS FOR SUPPLY AND INSTALLATION OF BACKFLOW PREVENTER AND/OR WATER AND/OR GAS METER ON SITE AS
REQUIRED.
5. ALL PIPING, PLUMBING FIXTURES, EQUIPMENT, AND ACCESSORIES SHALL BE INSTALLED IN A NEAT WORKMANLIKE MANNER. ALL MATERIALS SHALL BE FREE FROM DEFECTS. UNSIGHTLY
INSTALLATIONS OR DAMAGED MATERIAL SHALL BE REMOVED OR REWORKED AT NO EXPENSE TO THE OWNER.
6. REFER TO THE MECHANICAL DRAWINGS FOR ADDITIONAL COORDINATION WITH THESE DRAWINGS.
7. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING A BID.
8. EXISTING CONDITIONS SHOWN HEREIN WERE TAKEN FROM SITE OBSERVATIONS, ORIGINAL DESIGN DRAWINGS AND AS-BUILT DOCUMENTATION WHERE AVAILABLE; ANY DISCREPANCIES
BETWEEN THE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE ARCHITECT / ENGINEER.
2. PLUMBING FIXTURES AND EQUIPMENT:
1. THE CONTRACTOR SHALL PROVIDE ALL VALVES, PRESSURE REDUCING VALVES, SHOCK ABSORBERS AND ACCESSORIES TO COMPLETELY INSTALL ALL EQUIPMENT TO MAKE A COMPLETE
INSTALLATION.
2. PROVIDE WATER STOP VALVES AT EACH EQUIPMENT ITEM.
3. PIPING:
1. GENERAL:
1. ALL HORIZONTAL AND VERTICAL PIPING LINES EXTENDED AND CONNECTED TO EQUIPMENT SHALL BE RUN AT THE HIGHEST POSSIBLE ELEVATION AND NOT LESS THAN 4” ABOVE THE
FLOOR TO PROVIDE CLEARANCE FOR CLEANING. AT WALL OR COLUMN LOCATIONS, PIPING ROUGH IN SHALL BE STUBBED IN WALLS WHEREVER POSSIBLE.
2. DO NOT ROUTE ANY PIPING DIRECTLY OVER ELECTRICAL PANELS AND EQUIPMENT, ELEVATOR EQUIPMENT AND CONTROLS, OR TELECOMMUNICATIONS EQUIPMENT. SEE
ELECTRICAL DRAWINGS FOR EXACT EQUIPMENT LOCATIONS.
2. WASTE & VENT:
1. WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC – DWV.
2. SLOPES OF SANITARY WASTE AND VENT SHALL BE ESTABLISHED AND VERIFIED BY THE CONTRACTOR PRIOR TO PIPING BEING INSTALLED IN ORDER THAT PROPER SLOPES AND
NECESSARY INVERT ELEVATIONS ARE OBTAINED.
3. CLEANOUTS FOR SOIL AND WASTE LINES SHALL BE INSTALLED WHERE INDICATED ON THE DRAWINGS, WITHIN EVERY 100 FT, AT THE BOTTOM OF EACH WASTE STACK, AND EVERY
90-DEGREE CHANGE IN DIRECTION.
4. CAST IRON SANITARY WASTE PIPING SHALL BE INSTALLED FOR THE FIRST TWENTY FEET ON DRAINS SERVING BOILER ROOMS, FOOD PREP/DISHWASHING, STERILIZERS, OR ANY
OTHER EQUIPMENT THAT MAY DISCHARGE WASTEWATER ABOVE 140°F.
5. INDIRECT WASTE LINES REQUIRED FOR STANDARD AND/OR FABRICATED ITEMS OF KITCHEN EQUIPMENT SHALL BE FURNISHED, INSTALLED AND EXTENDED TO DRAIN POSITION.
4. SHOP DRAWINGS:
1. EQUIPMENT AND MATERIALS SUBMITTED AS ALTERNATES TO THE SPECIFIED DATA MUST BE CLEARLY MARKED AS TO THE DIFFERENCES IN SUBMITTED VERSUS SPECIFIED. FAILURE TO
CLEARLY MARK THE SUBMITTALS AS SUCH IS GROUNDS FOR REJECTION. SUBMITTALS NOT CLEARLY MARKED AS BEING ALTERNATE TO THE SPECIFIED DATA CAN BE ASSUMED TO MEET ALL
SPECIFIED REQUIREMENTS AND PROVIDER IS RESPONSIBLE TO PROVIDE AS SUCH.
TYPICAL PLUMBING NOTES:
PART 1. GENERAL:
1.01. PLUMBING SYSTEMS: WORK INCLUDED UNDER THIS SECTION CONSISTS OF PLUMBING WORK, PRINCIPAL SYSTEMS OF
WHICH ARE AS FOLLOWS:
A. WASTE PIPING SYSTEM: PROVIDE SANITARY WASTE DRAINAGE AND VENT PIPING INCLUDING CONNECTING FIXTURES PROVIDED
UNDER THIS AND OTHER SECTIONS.
PART 2. PRODUCTS:
2.01. ACCESS PANELS:
A. PROVIDE MINIMUM 12” X 12” ACCESS PANELS AT LOCATIONS NECESSARY FOR ACCESS TO VALVES, SHOCK ABSORBERS, TRAP
PRIMERS, ETC. COORDINATE LOCATION OF ACCESS PANELS WITH GENERAL CONTRACTOR.
2.02. INTERIOR WATER PIPING:
A. PIPING ABOVE GROUND: PIPING 3” AND SMALLER SHALL BE ASTM B-88 HARD DRAWN TYPE L COPPER ASSEMBLED WITH
WROUGHT COPPER SOLDER FITTINGS. PIPING LARGER THAN 3” SHALL BE ASTM 1-120-55 GALVANIZED STEEL WITH GALVANIZED
MALLEABLE IRON FITTINGS.
B. PIPING BELOW GROUND: ALL PIPING SHALL BE TYPE K COPPER, ASTM B-88.
C. BRASS OR BRONZE ADAPTOR FITTING SHALL BE USED WHERE NECESSARY AND SHALL BE IRON PIPE SIZE AND THICKNESS WHERE
REQUIRED FOR FIXTURE OR EQUIPMENT CONNECTIONS. CONNECTIONS OF COPPER PIPE TO FERROUS PIPE SHALL BE MADE WITH
DIELECTRIC UNIONS OR COUPLINGS.
2.03. INTERIOR SANITARY SEWERS:
A. WASTE AND VENT PIPING ABOVE GRADE SHALL BE SCHEDULE 40 PVC WITH D.W.V. FITTINGS. PVC PIPE SHALL NOT BE USED IN
RETURN AIR PLENUMS.
B. CONTRACTOR'S OPTION: NO HUB CAST IRON TYPE CIS.
2.03. CLEANOUTS
A. CLEANOUTS SHALL BE JOSAM, J.R. SMITH, ZURN, OR APPROVED SUBSTITUTE, AND SHALL BE INSTALLED FULL SIZE OF TRAP OR
PIPE. FULL SIZE WYE AND TEE BRANCHES SHALL BE PROVIDED FOR CLEANOUTS AS REQUIRED BY CONDITIONS AT THE BUILDING.
CLEANOUT PLUGS SHALL BE CAST IRON WITH NEOPRENE OR LEAD SEALS AND SHALL BE LUBRICATED.
B. CLEANOUTS: (ZURN NUMBERS LISTED):
(1) EXTERIOR: ZN-1420-27, CAST IRON CUTOFF FERRULE WITH ROUND SCORIATED FRAME AND COVER, SECURED.
(2) FINISHED CONCRETE FLOORS: ZN-1405-2, INSIDE CAULK ROUND NICKEL ALLOY SCORIATED FRAME AND
COVER.
(3) CERAMIC TILE FLOORS: ZN-1405-3 EQUAL INSIDE CAULK WITH ROUND NICKEL ALLOY SCORIATED FRAME AND
COVER.
(4) RESILIENT TILE FLOORS: ZN-1405-7, INSIDE CAULK WITH ROUND RECESSED NICKEL ALLOY SMOOTH ROUND
FRAME AND COVER.
(5) WALL: ZN-1445 WITH ACCESS COVER.
(6) NOTE: USE CLAMPING DEVICE ON CLEANOUTS THAT OCCUR IN FLOORS HAVING WATERPROOF MEMBRANE.
PLUMBING SPECIFICATIONS
PART 3. EXECUTION:
3.01. WASTE, VENT, AND DRAINAGE:
A. USE REDUCING FITTINGS FOR CHANGES IN PIPE SIZE.
B. FITTINGS FOR WASTE, VENT, AND DRAINAGE PIPING TO BE DRAINAGE PATTERN TYPE.
C. SOIL, WASTE, AND VENT PIPING ABOVE GROUND SHALL BE CONCEALED IN WALLS, CHASES, PIPE SHAFTS AND CEILING SPACES, EXCEPT IN EQUIPMENT ROOMS AND SIMILAR UNFINISHED AREAS AND ELSEWHERE AS SPECIFICALLY INDICATED OTHERWISE.
ALL SOIL AND WASTE PIPING INSIDE THE BUILDING SHALL BE RUN WITH A UNIFORM DROP OF NOT LESS THAT 1/8” PER FOOT, USING ¼” PER FOOT WHERE POSSIBLE.
3.03. CLEANOUTS
A. LOCATE LINE SIZE CLEANOUTS, AT BASE OF EACH SOIL AND WASTE STACK; AT EACH CHANGE IN DIRECTION IN SOIL, WASTE, AND
DRAIN LINES; AND IN ALL HORIZONTAL DRAIN LINES, WITH SPACING NOT TO EXCEED 50' INSIDE THE BUILDING AND 75' OUTSIDE
THE BUILDING.
B. CLEANOUTS NOT ACCESSIBLE, WHICH CANNOT BE MADE EASILY ACCESSIBLE OTHERWISE, SHALL BE EXTENDED UP THROUGH
FLOOR OR WALL.
3.04. ELECTRICAL GROUND:
A. THIS CONTRACTOR SHALL MAKE PROVISIONS FOR MAINTAINING THE ELECTRICAL GROUND PROPERTIES OF WATER LINES BY
STRAPPING OVER VALVES OR EQUIPMENT WHOSE REMOVAL FOR SERVICE WORK IN FUTURE WOULD BREAK GROUNDING
SERVICE. STRAPPING OVER SHALL BE DONE WITH A LENGTH OF BRAIDED COPPER CABLE WHICH SHALL BE ATTACHED TO PIPE
AT EITHER END.
3.05. FIXTURE CONNECTIONS:
A. CONNECT TO PLUMBING FIXTURES AND EQUIPMENT PROVIDED UNDER THIS AND OTHER SECTIONS OF SPECIFICATIONS.
B. SEE SCHEDULE ON PLANS FOR CONNECTIONS SIZES TO FIXTURES.
3.06. TRENCHING AND BACKFILLING:
A. TRENCHES SHALL PROVIDE UNIFORM BEARING. WHERE ROCK IS ENCOUNTERED, EXCAVATE 3” BELOW THE PIPE AND REFILL TO
PIPE GRADE WITH GRAVEL. AFTER TESTING OF PIPING, TRENCHES SHALL BE BACKFILLED TO GRADE, TAMPED TO 95%
COMPACTION.
3.07. TEST AND INSPECTIONS:
A. MAKE ALL WATER AND AIR TESTS OF THE PIPING SYSTEMS BEFORE WORK IS CONCEALED. TEST WATER PIPING TO
HYDROSTATIC PRESSURE OF 125 PSI AND HOLD FOR 24 HOURS.
B. AFTER THE INSTALLATION OF SANITARY PIPING, PLUG THE ENDS OF THE SYSTEM AND FILL WITH WATER TO THE TOP OF VENTS
OR WITH 10' HEAD. SHOULD LEAKS APPEAR, REPAIR AND REPEAT THE TESTS UNTIL THE SYSTEM IS TIGHT.
3.09. AS-BUILT DRAWINGS:
A. THE PLUMBING CONTRACTOR SHALL FURNISH UPON COMPLETION OF WORK A PLUMBING PLAN SHOWING ALL PIPING AS
INSTALLED.
3.10. WORKMANSHIP
A. PLUMBING EQUIPMENT SHALL BE INSTALLED IN A NEAT WORKMANLIKE MANNER. UNSIGHTLY INSTALLATIONS SHALL BE
REMOVED OR REWORKED AT NO ADDITIONAL EXPENSE TO THE OWNER.
END OF SECTION
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/3
/2
:5
:3
A
M C
U se rs
\s te v e n th o m a s\ D o cu m e n ts
\1
-G ra y so n e le v a to r_ p lu m b
-F P st h o m a s@ t-l.
co m .r v t
P001
19736
PROJECT CODE: 260-B5260-075 / M25WC153
RTB
RTB
SGT
09/03/2026
IS
S
U E
D F
O R
B
ID
S W
C C
G R
A
YS
O N
H A
LL
E
LE
V
A
TO
R A
N D
LO
A
D
IN
G D
O C
K W
YT
H
EV
IL
LE
, V
IR
G
IN
IA
P
LU
M B
IN
G
N O
TE
S, S P
EC
IF
IC
A
TI
O
N S
L
EG
EN
D
N o
D at e
R e vi si o n
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/3
/2
:5
:3
A
M C
U se rs
\s te v e n th o m a s\ D o cu m e n ts
\1
-G ra y so n e le v a to r_ p lu m b
-F P st h o m a s@ t-l.
co m .r v t
P002
19736
PROJECT CODE: 260-B5260-075 / M25WC153
RTB
RTB
SGT
09/03/2026
IS
S
U E
D F
O R
B
ID
S W
C C
G R
A
YS
O N
H A
LL
E
LE
V
A
TO
R A
N D
LO
A
D
IN
G D
O…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .