Drawing_files___MECH_W91QVN18R0249.PDF
PDF 3 MB Posted
- Attached to
- Repair Operation Facilities in AHA No. 23
- Solicitation number
- W91QVN18R0249
About this file
DRAWING - Mechanical
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L E G E N D
M-1
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
BELL AND SPIGOT
TRAP, ELECTRIC (INDICATE TYPE)
SOLVENT CEMENT
REDUCER, ECCENTRIC (STRAIGHT, INVERT)
REDUCER, ECCENTRIC (STRAIGHT, DOWN)
FIRE DEPARTMENT CONNECTION
M E C H A N I C A L M A T E R I A L I N D I C A T I O N S & S Y M B O L S
TEE, OUTLET DOWN
ANCHOR, MAIN
BUTTERFLY
AIR LINE
valves : (for selective actuators)
GATE, ANGLE
PLUG VALVE
GATE, GLOBE
THREE WAY
CONTROL
DPT DEWPOINT TEMPERATUREAMERICAN WIRE GAUGEAWG
CENTIGRADE
CAPACITY
BRAKE HORSEPOWER
BAROMETER(-TRIC)
BOILING POINT
PRESSURE, BAROMETRIC
COOLING LOAD
COEFFICIENT
CUBIC METER PER HOUR
COUNTER CLOCKWISE
CLASSIFICATION
CAST IRON PIPE
CHILLED WATER
CIRCUIT
CUBIC METER
COMPRESSOR
CONTINUE
CONNECTIONCONN
CONT
CU M
CPRSR
CLASS
CLG LOAD
COEF
CMH
CKT
CIP
CHW
CCW
C
CAP
BP
BARO PR
BARO
BHP
FA FACE AREA OR FRESH AIR
FHC
FLA
FHY FIRE HYDRANT
FULL LOAD AMPERES
FIRE HOSE CABINET
EFF
EWT
EXPJT
EVAP
EP
EQPT
ESP
ENT
ECON
EDR
EAT
ECC
DX
DPDT
DPV
EFFICIENCY
EXPANSION JOINT
EXTERNAL STATIC PRESSURE
EVAPORAT (-E,-ING,-ED,-OR)
ENTERING WATER TEMP
EXPLOSION PROOF
ENTERING
EQUIPMENT
DRY PIPE VALVE
DOUBLE POLE DOUBLE THROW
ENTERING AIR TEMPERATURE
EQUIVALENT DIRECT RADIATION
DIRECT EXPANSION
ECONOMIZER
ECCENTRIC
air conditioning and refrigeration
AIR COOLED
ALARM CHECK VALVE
AIR CONDITION UNIT (S)
AVERAGE
APPROXIMATE
AMPERE(AMP, AMPS)
AIR HANDLING UNIT
ALTITUDE
AMBIENT
ALUMINUM
APPARATUS DEW POINT
AIR CONDITION (-ING,-ED)
AIR COOLED CONDENSING UNIT
APPROX
AVG
AMP
AMB
AIR COND
ALT
AL
AHU
ACCU
ACLD
ACU
ACV
ADP
C/HWS
C/HWR
CHS
CHR
D
RS
RL
RD
(NAME)
M
CU MM
DIAG
DO
DIV
DIFF
DB
DIA or
DBT
CW
Cv
CWP
DECIBEL OR DRY BULB
DRY BULB TEMPERATURE
DIAGRAM
DIVISION
DIESEL OIL
DIFFERENCE
DIAMETER
DEGREE
o
CUBIC MILLIMETER
COEFFICIENT, VALVE FLOW
CLOCKWISE OR COLD WATER
CIRCULATING WATER PUMP
HOT/CHILLED WATER SUPPLY
HOT CHILLED WATER RETURN
CHILLED WATER RETURN
CHILLED WATER SUPPLY
DRAIN
REFRIGERANT SUCTION
REFRIGERANT LIQUID
CONTROL AIR MAIN
PIPE TO BE REMOVED
REFRIGERANT DISCHARGE
GLOBE
GATE
A
BALL
SQ
PLUMBING
LIQUID LINELL
PLMB
LINEAR METER
LITERS PER DAY
LITERS PER HOUR
LAUNDRY TRAY
LITERS PER SECOND
LEAVING WATER TEMPERATURE
NOT APPLICABLE
NOISE CRITERIA
NORMALLY CLOSED
METERS PER SECOND
METERS PER HOUR
MINIMUM OR MINUTE
NORMALLY OPEN
NATIONAL TAPER PIPE (THREAD)
NOT IN CONTRACTNICKG KILOGRAM
KILOGRAM PER SQ. CENTIMETER (ABSOLUTE)
KILOGRAM PER SQ. CENTIMETER
KILOGRAM PER SQ. CENTIMETER (GAUGE)KG/SQ CM G
KG/SQ CM A
KG/SQ CM
NO
N.O.
NPT
NUMBER
KILOCALORIE PER HOUR
THERMAL CONDUCTIVITY
JOULE
IRON PIPE SIZE
ISOMETRIC
DIAMETER, INSIDE
KCAL/HR
K
J
ISO
ID
IPS
HEAD
HERTZ
HORIZONTAL
HORSEPOWER
HOT WATER
HOT WATER HEATER
HOUR(S)
MERCURY
HORIZ
HZ
HW
HWH
HP
HR
HD
HG
MAX MAXIMUM
NC
N/A
N.C.
MM
MPH
MPS
MIN
MILLIMETER
M
LT
LWT
LM
LPH
LPS
LPD
METERS
SUPPLY AIRSA
SANITARY
SUBMERSIBLE
SCHEDULE
SAN
SCH
SBM
UH
UR
U
QUART
QUANTITY
PERCENT
PETROLEUM, OIL AND LUBRICANTS
POINT OF CONNECTION
PARTS PER MILLION
PRESSURE REDUCING VALVE
RADIATOR
REFRIGERANT (12, 22, ETC)
REVOLUTIONS PER MINUTE
REFRIGERATION TON
THERMAL RESISTANCE
RETURN AIR
RELATIVE HUMIDITY
RT
RH
RPM
R12, R22
R
RA
RDTR
QT
QTY
PPM
PRV
POC
POL
THERM
TONS
TYP
THK
TSTAT
TD
TEMP
SYM
STOR
SUCT
STD
STL
SSU
SSF
SST
ST
FLEXIBLE CONNECTOR
EXPANSION JOINT
EXPANSION LOOP
FLOWMETER, ORIFICE
KILOGRAM PER SQ. METER (GAUGE)
KILOGRAM PER SQ. METER (ABSOLUTE)
KILOGRAM PER SQ. METER
STRAINER, BLOW OFF
PUMP (INDICATE USE)
PRESSURE GAUGE AND COCK
PRESSURE SWITCH
KILOWATT HOUR
LATENT HEAT
LEAVING AIR TEMPERATURE
FLOWMETER, VENTURI
A B B R E V I A T I O N S
FIBERGLASS REINFORCED PLASTIC
FEMALE PIPE THREAD
GRAMS
HOSE BIBB
FACE VELOCITY
FEED WATER PUMP
GAGE OR GAUGE
GALVANIZED STEEL
FIXTURE
GA
GALVS
HB
GR
FXTR
FVEL
FWP
FLUSH VALVE
FREQUENCY
FUEL OILFO
FREQ
FRP
FPT
FV
LAT
LH
LG
LBS
L
LAV
KWH
LENGTH
POUNDS
LITERS
LAVATORY
KG/SM G
KG/SM A
KG/SM
KJ
KW
KILOJOULE
KILOWATT
P
PS
FS
STRAINER
FLOW SWITCH
OFM
VFM
EJ
BALL JOINT
(2-WAY SHOWN)
OUTSIDE AIR
NOT TO SCALE
OUTSIDE AIR INTAKE LOUVER
POLE
OXYGEN
PASCAL
PRESSURE DROP OR DIFFERENCE
PHASE (ELECTRIC)
PRESSURE GAGE
OUTSIDE SCREW & YOKE
DIAMETER, OUTSIDE
PH
PG
Pa
PD
P
OXY
OS&Y
NTS
OA
OD
OAIL
SPR
SP
SPEC
SPDT
SM
SLPD
SLPS
SLPH
SEC
SF
SG
SH
SL
sprinkler
DRY-PIPE VALVE
PRE-ACTION VALVE
SIDEWALL SPRINKLER
ALARM CHECK VALVE
PENDENT SPRINKLER
UNION, SCREWED
UNION, FLANGED
TEE, SINGLE SWEEP
UPRIGHT SPRINKLER
COLD WATER
HOT WATER SUPPLY
HOT WATER RETURN
CONDENSATE DRAIN ABOVE
SANITARY DRAIN
ACID WASTE
CHEMICAL SUPPLY PIPES
FLOOR DRAIN
CONDENSATE DRAIN BELOW
FLOOR OR GRADE
FUNNEL DRAIN, OPEN
SURFACE CLEANOUT
VENT THRU ROOF
FLOOR CLEANOUT
PIPE SLEEVE
HOSE BIBB
BACKFLOW PREVENTER
PIPE SLEEVE WITH FIRE STOPPING
FLOOR SINK (200mm x 200mm)
PITCH OR PIPE, UP(U), DOWN(D)
FLOOR OR GRADE
(NAME)E
VAC
A
HWS
MTWR
HWR
MTWS
CR
CS
FOG
FOR
FOS
FOV
FOD
MU
VPD
PC
BBD
MPC
LPC
LPS
MPS
JWS
JWR
FCO
LOW TEMPERATURE HOT WATER RETURN
LOW TEMPERATURE HOT WATER SUPPLY
MEDIUM TEMPERATURE HOT WATER RETURN
MEDIUM TEMPERATURE HOT WATER SUPPLY
VACUUM (AIR)
COMPRESSED AIR
EXISTING PIPE
FUEL OIL RETURN
FUEL OIL SUPPLY
CONDENSATE WATER RETURN
CONDENSATE WATER SUPPLY
FUEL OIL GAUGE
PLAN ELEV.
BFP
200mm x 200mm
SCO
FUEL OIL TANK VENT
PUMPED CONDENSATE
BOILER BLOW DOWN
VACUUM PUMP DISCHARGE
FUEL OIL DRAIN
MAKE UP WATER
LOW PRESSURE STEAM
JACKET WATER SUPPLY
JACKET WATER RETURN
LOW PRESSURE CONDENSATE
MEDIUM PRESSURE CONDENSATE
MEDIUM PRESSURE STEAM
ACID
(NAME)
FD
CD
G GAS
CD
VENT
PIPING
heating plumbing
MOTOR ELECTRIC
CHECK, NON-SLAM
QUICK CLOSING, FUSIBLE LINK
SQUARE HEAD BALANCING COCK
PRESSURE REDUCING
SQUARE HEAD BALANCING COCK
HOSE END DRAIN
CONTROL, PNEUMATIC-ELECTRIC
CONTROL, ELECTRIC-PNEUMATIC
ALIGNMENT GUIDE
ANCHOR, INTERMEDIATE
AIR VENT, AUTOMATIC
AIR VENT, MANUAL
W/ MEASURING TAP
MV
AVV
S AIR SEPARATOR
S
R
SAFETY
QUICK OPENING
RELIEF
PE
LOCK SHIELD
NEEDLE
valves, special duty :
EP
M
S
CHECK, SWING
SOLENOID
DIAPHRAGM
LATERAL
TEE, OUTLET UP
REDUCER, CONCENTRIC
TEE
CONNECTION, TOP
ELBOW, TURNED UP
CONNECTION, BOTTOM
ELBOW, TURNED DOWN
fitting :
FLANGED
WELDED
R
SOLDERED
CAP
BUSHING
THERMOMETER
SCREWED
THERMOSTAT, ELECTRIC
valve actuators dampers
SQUARE
WATTHOUR OR WATER HEATER
HEAT TRANSFER COEFFICIENT
UNIT HEATER
URINAL
TEMPERATURE DIFFERENCE
TONS OF REFRIGERATION
THERMOMETER
THERMOSTAT
TYPICAL
THICKNESS
TEMPERATURE
SYMBOL
STAINLESS STEEL
SAYBOLT SECONDS FUROL
SAYBOLT SECONDS UNIVERSAL
STORAGE
SUCTION
STANDARD
STEEL
STEAM
WIDTH
WEIGHT
WASHER
WATERPROOF
WATER CLOSET
WATER-COOLED
W/
WT
WTRPRF
WSHR
WITH
WD
WH
WC
WCLD
FIRE DAMPER (PROVIDE ACCESS DOOR)
ELECTRIC MOTOR OPERATED DAMPER
SMOKE DAMPER (PROVIDE ACCESS DOOR)
PRESSURE, DYNAMIC(VELOCITY)
WET BULB TEMPERATURE
STATIC PRESSURE
LPD, STANDARD CONDITIONS
LPS, STANDARD CONDITIONS
LPH, STANDARD CONDITIONS
SINGLE POLE DOUBLE THROW
SPECIFICATION
SPRINKLER
SQUARE METER
SPECIFIC GRAVITY
SECOND
SAFETY FACTOR
SENSIBLE HEAT
SENSIBLE LOAD
VOLUME
VERTICAL
VISCOSITY
WET BULB
VENTILATION
WB
WBT
W
VP
WATT
VOL
VISC
VENT
VERT
VACUUM
VALVE
VARIABLE AIR VOLUME
VELOCITY
VOLTV
VAC
VLV
VAV
VEL
SD
AD
M
VD
AD FD
S
BDD
PNEUMATIC OPERATED DAMPER
SPLITTER DAMPER
BACKDRAFT DAMPER
MANUAL VOLUME DAMPER
DUCT SECTION, POSITIVE PRESS., FIRST
EXHAUST AIR GRILLE OR REGISTER, CEILING
DUCT SECTION, NEGATIVE PRESS., FIRST
ACCESS DOOR, VERTICAL OR HORIZONTAL
CHANGE OF ELEVATION, RISE(R), DOWN(D)
COWL, (GOOSENECK) AND FLASHING
F S
FC
TRANSITION
DETECTORS, FIRE AND/OR SMOKE
TURNING VANES
FLEXIBLE CONNECTION
SOUND ATTENUATOR
FLEXIBLE DUCT
AD
R
810mm x 400mm
810mm x 400mm
810mm x 400mm
FIGURE IS ON TOP
ACOUSTICAL LINING
DIRECTION OF FLOW
FIGURE IS ON TOP
(600mm x 300mmH, 472 LPS)
TG 600/300
NECK DIAMETER)
DIFFUSER, LINEAR
CEILING DIFFUSER, ROUND TYPE (200mm
CEILING DIFFUSER, SQUARE TYPE
EXISTING WORK TO BE REMOVED
200mm NCD
SUPPLY AIR GRILLE OR REGISTER, CEILING
EXHAUST AIR GRILLE OR REGISTER, CEILING
SUPPLY AIR GRILLE OR REGISTER, SIDEWALL
RETURN AIR GRILLE OR REGISTER, CEILING
TRANSFER GRILLE ASSEMBLY
LOUVER, DOOR OR WALL
UNDERCUT DOOR (13mm, 47.2 LPS)
DOOR GRILLE (300mmx150mmH)
(500mmWx300mmH, 94.4 LPS)
500/300L
47.2
UC 13mm
300x150
DG
94.4
SR
RR
RG
SG
EG
ER
SR
SG
DUCT WORK
grilles, registers and diffusers :
RLA
LRA
RATED LOAD AMPS
LOCKED ROTOR AMPS
REMOVE EXIST WORK(R)
(E) EXISTING WORK TO REMAIN.
OR END OF DEMOLITION WORK
POINT OF CONNECTION NEW TO EXISTING
SYMBOLS
MECHANICAL MATERIAL INDICATIONS &
(OPERATION BLDG S-246)
REPAIR OPERATION FACILITES IN AHA 23
CAMP CASEYCHONG, ST
186681
M-2
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
GALVANIZED STEEL PIPE WITH CAST IRON DRAINAGE FITTINGS.
ABOVEGROUND VENT PIPING WILL BE HUBLESS CAST IRON PIPE AND FITTINGS OR
LAGGED COPPER PIPING. SOIL, WASTE, AND VENT PIPING WILL BE CAST IRON SOIL PIPE.
WITH TIN-ANTIMONY SOLDERED ENDS. HOT WATER PIPING WILL BE INSULATED AND
TYPE. WATER PIPING SHALL BE COPPER. FITTINGS SHALL BE CAST BRONZE OR COPPER
13. PLUMBING FIXTURES SHALL BE OF COMMERCIAL GRADE AND OF WATER CONSERVING
MAKING ALL NECESSARY DUCT CONNECTIONS FUNCTION AS ORIGINALLY INTENDED.
INSTALLATION, REMOVE THE EXISTING DUCTWORK AND REPLACE WITH NEW DUCTWORK,
EXISTING DUCTWORK ELEVATION AND LOCATION IS IN CONFLICT WITH THE NEW PIPING
MUST COORDINATE WITH THE EXISTING DUCTWORK ELEVATIONS AND LOCATION. IF THE
12. PRIOR TO THE INSTALLATION OF NEW HVAC AND PLUMBING PIPING, THE CONTRACTOR
CONTRACTING OFFICER FOR APPROVAL.
CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED TO THE
FIELD CONDITIONS. SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE
11. SOME DETAILS SHOWN ON THE CONTRACT DRAWINGS MAY NOT MATCH EXACTLY TO THE
SUCH AS ANCHORS, HANGERS/SUPPORTS, ETC.
10. ALL HVAC PIPING/DUCTWORK TO BE REMOVED SHALL INCLUDE ALL ITS ACCESSORIES,
PATCHED OR RESTORED TO MATCH THE ADJACENT SURFACE OR AREA.
9. ANY OPENING RESULT FROM THE REMOVAL WORK THAT IS NOT TO BE REUSED SHALL BE
DUCTWORK SHALL MEET THE REQUIREMENTS OF SEAL CLASS C.
ACCORDING TO SMACNA STATIC PRESSURE CONSTRUCTION CLASS 500PA AND
8. ALL SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED
AREA.
DUCTWORK SHALL BE PATCHED OR RESTORED TO MATCH THE ADJACENT SURFACE OR
7. ALL WALL/FLOOR/ROOF OPENINGS RESULTING FROM THE REMOVAL OF PIPING AND
SHOP DRAWING SHALL NOT BE THE EXACT DUPLICATION OF THE CONTRACT DRAWING.
6. NO MECHANICAL WORK CAN BE STARTED WITHOUT AN APPROVED SHOP DRAWING. A
5. CONCRETE REMOVAL AND RESTORATION SHALL CONFORM TO SPEC.
4. ANY PIPES THAT PENETRATE FIRE RATED WALLS (EXISTING/NEW) SHALL BE SEALED PER SPEC.
OR REPLACED BY THE CONTRACTOR.
DAMAGES DUE TO THE WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED
DAMAGE THE EXISTING EQUIPMENT, NEW EQUIPMENT, DUCTWORK, PIPING, ETC.
3. CONNECTIONS TO EXISTING SYSTEMS SHALL BE DONE IN SUCH A MANNER AS NOT TO
APPROXIMATE AND SHALL BE VERIFIED AT THE JOB SITE.
2. LOCATION AND SIZES OF EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. ARE
CORRECTIONS FOR THE CONTRACTING OFFICER'S APPROVAL.
CONTRACTING OFFICER'S REPRESENTATIVE WITH RECOMMENDATIONS FOR PROPER
DISCREPANCY IS DETECTED, IT SHOULD BE BROUGHT TO THE ATTENTION OF THE
EXISTING CONDITIONS, EQUIPMENT, FINISHES, ETC., PRIOR TO START OF WORK. IF ANY
1. THE CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH THE
GENERAL NOTES
GENERAL NOTES & SCOPE OF WORK
SCOPE OF WORK
REPAIR AND MAINTENANCE WORK (K-WORK)
GALVANIZED STEEL PIPE WITH CAST IRON DRAINAGE FITTINGS.
ABOVEGROUND VENT PIPING WILL BE HUBLESS CAST IRON PIPE AND FITTINGS OR
LAGGED COPPER PIPING. SOIL, WASTE, AND VENT PIPING WILL BE CAST IRON SOIL PIPE.
WITH TIN-ANTIMONY SOLDERED ENDS. HOT WATER PIPING WILL BE INSULATED AND
TYPE. WATER PIPING SHALL BE COPPER. FITTINGS SHALL BE CAST BRONZE OR COPPER
13. PLUMBING FIXTURES SHALL BE OF COMMERCIAL GRADE AND OF WATER CONSERVING
THE GROUNDING CONDUCTORS SHALL BE SEPARATELY PROVIDED FOR
MECHANICAL EQUIPMENT UNLESS OTHERWISE INDICATED ON THE DRAWING.
14.
15.
ALL ELECTRICAL WORK SHALL CONFORM TO THE CURRENT REQUIREMENTS
OF THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE,
FIRE CODE AND SPECIFICATIONS.
PROPER SIZE OF WIRE AND CONDUIT IN ACCORDANCE WITH MECHANICAL EQUIPMENT
SCHEDULE FOR GOVERNMENT APPROVAL PRIOR TO CONSTRUCTION.
16.
BLDG# S-246, CP CASEY
1. REPAIR BY REPLACEMENT OF EXISTING OIL TYPE DOMESTIC HOT WATER HEATER WITH ELECTRIC TYPE
DOMESTIC HOT WATER HEATER AND ASSOCIATED PIPING.
17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED AREA
INCLUDING SODDING, UTILITIES, STRUCTURES TO THEIR ORIGINAL CONDITION AND
OPERATION DURING AND AFTER INSTALLATION OF ELECTRICAL SYSTEM.
PURPOSE ONLY. CONTRACTOR SHALL VERIFY EXISITNG SITES CONDITION AND SUBMIT
SIZE AND COUNT OF WIRE, CONDUIT & ELECTRICAL DEVICES SHOWN ON DRAWING ARE ESTIMATED FOR BIDDING
2. REPAIR BY REPLACEMENT OF EXISTING ELECTRIC UNIT HEATER WITH NEW.
3. REPAIR BY REPLACEMENT OF EXISTING ROOF EXHAUST FAN, CEILLING FANS, CONTROL AND ASSOCIATED DUCTS WITH NEW.
5. REMOVE EXISTING FUEL OIL STORAGE TANK, DIKE AND ASSOCIATED OIL PIPING.
4. REMOVE AND REINSTALL EXISTING HEAT PUMP SYSTEM, CONTROL AND ASSOCIATED PIPING.
6. REPAIR BY REPLACEMENT OF EXISTING PLUMBING FIXTURES AND ASSOCIATED HW, CW, SEWER, VENT PIPING WITH NEW.
(OPERATION BLDG S-246)
REPAIR OPERATION FACILITES IN AHA 23
M-3
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
ROUND VERTICAL TYPE
TEMP.
SUPPLYSTORAGE
CAPACITY
T Y P E
ELEMENT CAPACITY
REMARKS
43.3208/3/60
LOWER: 3.5 KW
KW (DEG. C)VOLT/PH/HZ(LITS)
SERVICEITEM NO QTY
TOILET RM.1
ELECTRIC HOT WATER HEATER
EWH
1 UPPER: 3.5 KW
M E C H A N I C A L E Q U I P M E N T S C H E D U L E
1 21115/1/60142
CENTRIFUGAL FAN
ROOF MOUNTED, BELT DRIVEN,
EF
EF
R E M A R K SRPM
KW
(Pa)
ESP
(LPS)
AIR CAP
FAN MOTOR
VOLT/PH/HZ
W/ DISCONNECT SWITCH
BIRDSCREENW/ BACKDRAFT DAMPER
N O T ETYPES E R V I C EQ'TYITEM NO
1 4DIRECT DRIVEN, CENTRIFUGAL FAN
DISCHARGE
HORIZONTAL
TYPE
120/1/601
EUH
POWER
HEATING ELEMENT CAP
VOLT/PH/HZ
REMARKSSERVICEQTYNO
ELECTRIC UNIT HEATER
T Y P E
MECH RM
ITEM FAN CAPACITY
RPM VOLT/PH/HZAIR CAP.
1,600 120/1/60
(KW) (LPS)
AND BUILT-IN THERMOSTAT.
PROVIDE UNIT MTD. DISCONNECT SWITCH.
113 NON-SMULTANOUS OPERATION
189 6
WATTS
MOTOR
MECH ROOM
TOILET
EXHAUST FANS
CEILING MOUNTED,
1,050
115/1/60
0.025
0.018 CEILING GRILLE
MECHANICAL EQUIPMENT SCHEDULE
(OPERATION BLDG S-246)
REPAIR OPERATION FACILITES IN AHA 23
M-4
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
SPECIFIC NOTES
M6
FEC
OFFICE
OFFICE
VEST
OFFICE
SENTRY
AREA
VISITOR
ROOM
LOUNGE
TOILET
MEN
TOILET
WOMEN
OFFICE
CORRIDOR
ROOM
MECH
REMOVE EXISTING ALL FAN COIL UNITS ASSOCIATED PIPING.
1 1 1
REMOVE EXISTING ALL HVAC & PLUMBING PIPING.
REMOVE EXISTING ALL EQUIPMENTS AND ASSOCIATED PIPING IN MECH ROOM.
4 REMOVE EXISTING ALL EQUIPMENTS, PLUMBING FIXTURES AND ASSOCIATED PIPING IN TOILET.
RETURN FUEL TANK TO DPW WITH FUEL OIL TANK CLEANING IAW KOREA ENVIRONMENTAL LAW.
REMOVE EXISTING FUEL OIL STORAGE TANK, DIKE AND OIL PIPING. RESTORE GROUND CONDITION SAME AS ADJACENT AREA.
REMOVE AND REISTALL EXISTING ALL HEAT PUMP SYSTEM, CONTROL AND ASSOCIATED PIPING.
REMOVAL FLOOR PLAN(BLDG# S-246, CP CASEY)
SCALE : 1 / 100
AND SPECIFIC NOTES
(BLDG# S-246, CP CASEY)
REMOVAL FLOOR PLAN
(OPERATION BLDG S-246)
REPAIR OPERATION FACILITES IN AHA 23
CAMP CASEYCHONG, ST
M-5
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M6
FEC
OFFICE
OFFICE
VEST
OFFICE
SENTRY
AREA
VISITOR
ROOM
LOUNGE
TOILET
MEN
TOILET
WOMEN
OFFICE
CORRIDOR
ROOM
MECH
EF
EF
EF
EUH
EWH
SCALE : 1 / 100
SEE
-M6
(BLDG# S-246, CP CASEY)
HVAC FLOOR PLAN
T
(OPERATION BLDG S-246)
REPAIR OPERATION FACILITES IN AHA 23
CAMP CASEYCHONG, ST
HVAC FLOOR PLAN(BLDG# S-246, CP CASEY)
M-6
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M6
FEC
TOILET
MEN
TOILET
WOMEN
ROOM
MECH
EWH
POC
WATER HAMMER ARRESTOR
(PDI:"A" TYPE)
WATER HAMMER ARRESTOR
(PDI:"A" TYPE)
WATER HAMMER ARRESTOR
(PDI:"A" TYPE)
WATER HAMMER ARRESTOR
(PDI:"A" TYPE)
RESPONSIBLE FOR VERIFYING ACTUAL QUANTITIES BASED ON THE CONTRACT DOCUMENTS
1. QUANTITIES ARE SHOWN FOR ESTIMATION PURPOSE ONLY, THE CONTRACTOR SHALL BENOTES :
REQUIREMENTS.
FLUSH VALVE WALL HUNG TYPE
WASTE
PIPE CONNECTION
H.W. VENT
BACK
R E M A R K S
C.W.
QTY.
P-1
P-5
SYMBOL
F I X T U R E
LAVATORY
WATER CLOSET2
COUNTER TOP.
20P-3 URINAL1 - 40 50
P-1
P-1
P-5 P-5
P-3
1 KITCHEN SINK
STANLESS STEEL TYPE50401515
FLUSH TANK TYPE
1.
NOTES:
CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION
2.
OF HW, CW, SEWER AND VENT PIPING IN FIELD(TYP)
(HOT & COLD WATER PIPING, SEWER AND VENT PIPING)
CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR PLUMBING PIPING
PRIOR TO HOT, COLD, SEWER, VENT PIPING INSTALLATION.
SCALE : 1 / 100
P-7
P-7
Q' TY
WATER HAMMER ARRESTER SCHEDULE
FIXTURE
UNIT RATING
CONN.
SIZE
P.D.I
SYMBOL
REMARK
1 - 11A
( TYPICAL )
12 - 32B
15 mm
20 mm COMPRESSION CHAMBER WITH EXPANSION
STAINLESS STEEL CONSTRUCTION PRESSURIZED
PLUMBING FIXTURE SCHEDULE
AND WATER HAMMER ARRESTER SCH.
PLUMBING FIXTURE SCHEDULE, NOTES
(BLDG# S-246, CP CASEY)
PLUMBING PARTIAL FLOOR PLAN
T
(OPERATION BLDG S-246)
REPAIR OPERATION FACILITES IN AHA 23
CAMP CASEYCHONG, ST
PLUMBING PARTIAL FLOOR PLAN(BLDG# S-246, CP CASEY)
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
M-7
MECHANICAL
DIVISION 7 WORK
BACKDRAFT MOTORIZED
INSULATED ROOF CURVE,
EXHAUST DUCT WORK
POWER ROOF VENTILATOR
POWER ROOF VENTILATOR
MIN. 2 EACH SIDE
BY FAN MFR.,
RECOMMENDED
LAGBOLTS AS
CURB HT.
300 MIN.
SEE ARCH. DWGS.
WOOD BLOCKING,
SEE ARCH. DWGS.
ROOF CONSTR.
SEE ARCH. DWGS.
WOOD NAILER
ALL AROUND
GASKET SEAL
(SPECIFIED IN DIVISION 7)
FLASHING
UNIT HOOD
M
DAMPER
MOTOR
DAMPER
ELECTRIC WATER HEATER
COMBINATION TEMPERATURE
AND PRESSURE RELIEF VALVE
BALL VALVE
SHALL BE 150 LARGER
DRAIN PAN
THAN WATER HEATER
VACUUM BREAKER
ELECTRIC WATER
BALL VALVE
COLD WATER
SERVICE LINE
32HOT WATER
SUPPLY LINE
THAN DRAIN PAN
NOTE :
IN CLG. SPACE
HEATER SUSPENDED
INSTALL WATER HEATER 100HIGHER
DOWN AND DISCHARGE
TO THE NEAREST FLOOR DRAIN
FULL SIZE DRAIN PIPE
NEAREST FLOOR DRAIN
DISCHARGE TO THE
15DRAIN VALVE
"C"
"A"
"B"
TYPE
33-60128 125
WATER HAMMER ARRESTOR
94 81
115 81
HEIGHT DIAMETER
1-11
12-32
CAPACITY
FIXTURE UNIT
FIXTURE
TO LAST
THREADED PLUG
FROM BRANCH
SUPPLY
AND SIZE
20 OR 25 SEE
DWGS FOR LOCATION
PRESSURE PNEUMATIC
STAINLESS STEELSHELL
STAINLESS STEEL
ORIFICE
FLOW CONTROL
H E
IG
H
T DISPLACEMENT
ADAPTER
FLUID
BELLOWS
HYDRAULIC
CUSHION
DISPLACEMENT
DIAMETER
-M7 M7 M7
DETAILS
(OPERATION BLDG S-246)
REPAIR OPERATION FACILITES IN AHA 23
L E G E N D
M-1
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
BELL AND SPIGOT
TRAP, ELECTRIC (INDICATE TYPE)
SOLVENT CEMENT
REDUCER, ECCENTRIC (STRAIGHT, INVERT)
REDUCER, ECCENTRIC (STRAIGHT, DOWN)
FIRE DEPARTMENT CONNECTION
M E C H A N I C A L M A T E R I A L I N D I C A T I O N S & S Y M B O L S
TEE, OUTLET DOWN
ANCHOR, MAIN
BUTTERFLY
AIR LINE
valves : (for selective actuators)
GATE, ANGLE
PLUG VALVE
GATE, GLOBE
THREE WAY
CONTROL
DPT DEWPOINT TEMPERATUREAMERICAN WIRE GAUGEAWG
CENTIGRADE
CAPACITY
BRAKE HORSEPOWER
BAROMETER(-TRIC)
BOILING POINT
PRESSURE, BAROMETRIC
COOLING LOAD
COEFFICIENT
CUBIC METER PER HOUR
COUNTER CLOCKWISE
CLASSIFICATION
CAST IRON PIPE
CHILLED WATER
CIRCUIT
CUBIC METER
COMPRESSOR
CONTINUE
CONNECTIONCONN
CONT
CU M
CPRSR
CLASS
CLG LOAD
COEF
CMH
CKT
CIP
CHW
CCW
C
CAP
BP
BARO PR
BARO
BHP
FA FACE AREA OR FRESH AIR
FHC
FLA
FHY FIRE HYDRANT
FULL LOAD AMPERES
FIRE HOSE CABINET
EFF
EWT
EXPJT
EVAP
EP
EQPT
ESP
ENT
ECON
EDR
EAT
ECC
DX
DPDT
DPV
EFFICIENCY
EXPANSION JOINT
EXTERNAL STATIC PRESSURE
EVAPORAT (-E,-ING,-ED,-OR)
ENTERING WATER TEMP
EXPLOSION PROOF
ENTERING
EQUIPMENT
DRY PIPE VALVE
DOUBLE POLE DOUBLE THROW
ENTERING AIR TEMPERATURE
EQUIVALENT DIRECT RADIATION
DIRECT EXPANSION
ECONOMIZER
ECCENTRIC
air conditioning and refrigeration
AIR COOLED
ALARM CHECK VALVE
AIR CONDITION UNIT (S)
AVERAGE
APPROXIMATE
AMPERE(AMP, AMPS)
AIR HANDLING UNIT
ALTITUDE
AMBIENT
ALUMINUM
APPARATUS DEW POINT
AIR CONDITION (-ING,-ED)
AIR COOLED CONDENSING UNIT
APPROX
AVG
AMP
AMB
AIR COND
ALT
AL
AHU
ACCU
ACLD
ACU
ACV
ADP
C/HWS
C/HWR
CHS
CHR
D
RS
RL
RD
(NAME)
M
CU MM
DIAG
DO
DIV
DIFF
DB
DIA or
DBT
CW
Cv
CWP
DECIBEL OR DRY BULB
DRY BULB TEMPERATURE
DIAGRAM
DIVISION
DIESEL OIL
DIFFERENCE
DIAMETER
DEGREE
o
CUBIC MILLIMETER
COEFFICIENT, VALVE FLOW
CLOCKWISE OR COLD WATER
CIRCULATING WATER PUMP
HOT/CHILLED WATER SUPPLY
HOT CHILLED WATER RETURN
CHILLED WATER RETURN
CHILLED WATER SUPPLY
DRAIN
REFRIGERANT SUCTION
REFRIGERANT LIQUID
CONTROL AIR MAIN
PIPE TO BE REMOVED
REFRIGERANT DISCHARGE
GLOBE
GATE
A
BALL
SQ
PLUMBING
LIQUID LINELL
PLMB
LINEAR METER
LITERS PER DAY
LITERS PER HOUR
LAUNDRY TRAY
LITERS PER SECOND
LEAVING WATER TEMPERATURE
NOT APPLICABLE
NOISE CRITERIA
NORMALLY CLOSED
METERS PER SECOND
METERS PER HOUR
MINIMUM OR MINUTE
NORMALLY OPEN
NATIONAL TAPER PIPE (THREAD)
NOT IN CONTRACTNICKG KILOGRAM
KILOGRAM PER SQ. CENTIMETER (ABSOLUTE)
KILOGRAM PER SQ. CENTIMETER
KILOGRAM PER SQ. CENTIMETER (GAUGE)KG/SQ CM G
KG/SQ CM A
KG/SQ CM
NO
N.O.
NPT
NUMBER
KILOCALORIE PER HOUR
THERMAL CONDUCTIVITY
JOULE
IRON PIPE SIZE
ISOMETRIC
DIAMETER, INSIDE
KCAL/HR
K
J
ISO
ID
IPS
HEAD
HERTZ
HORIZONTAL
HORSEPOWER
HOT WATER
HOT WATER HEATER
HOUR(S)
MERCURY
HORIZ
HZ
HW
HWH
HP
HR
HD
HG
MAX MAXIMUM
NC
N/A
N.C.
MM
MPH
MPS
MIN
MILLIMETER
M
LT
LWT
LM
LPH
LPS
LPD
METERS
SUPPLY AIRSA
SANITARY
SUBMERSIBLE
SCHEDULE
SAN
SCH
SBM
UH
UR
U
QUART
QUANTITY
PERCENT
PETROLEUM, OIL AND LUBRICANTS
POINT OF CONNECTION
PARTS PER MILLION
PRESSURE REDUCING VALVE
RADIATOR
REFRIGERANT (12, 22, ETC)
REVOLUTIONS PER MINUTE
REFRIGERATION TON
THERMAL RESISTANCE
RETURN AIR
RELATIVE HUMIDITY
RT
RH
RPM
R12, R22
R
RA
RDTR
QT
QTY
PPM
PRV
POC
POL
THERM
TONS
TYP
THK
TSTAT
TD
TEMP
SYM
STOR
SUCT
STD
STL
SSU
SSF
SST
ST
FLEXIBLE CONNECTOR
EXPANSION JOINT
EXPANSION LOOP
FLOWMETER, ORIFICE
KILOGRAM PER SQ. METER (GAUGE)
KILOGRAM PER SQ. METER (ABSOLUTE)
KILOGRAM PER SQ. METER
STRAINER, BLOW OFF
PUMP (INDICATE USE)
PRESSURE GAUGE AND COCK
PRESSURE SWITCH
KILOWATT HOUR
LATENT HEAT
LEAVING AIR TEMPERATURE
FLOWMETER, VENTURI
A B B R E V I A T I O N S
FIBERGLASS REINFORCED PLASTIC
FEMALE PIPE THREAD
GRAMS
HOSE BIBB
FACE VELOCITY
FEED WATER PUMP
GAGE OR GAUGE
GALVANIZED STEEL
FIXTURE
GA
GALVS
HB
GR
FXTR
FVEL
FWP
FLUSH VALVE
FREQUENCY
FUEL OILFO
FREQ
FRP
FPT
FV
LAT
LH
LG
LBS
L
LAV
KWH
LENGTH
POUNDS
LITERS
LAVATORY
KG/SM G
KG/SM A
KG/SM
KJ
KW
KILOJOULE
KILOWATT
P
PS
FS
STRAINER
FLOW SWITCH
OFM
VFM
EJ
BALL JOINT
(2-WAY SHOWN)
OUTSIDE AIR
NOT TO SCALE
OUTSIDE AIR INTAKE LOUVER
POLE
OXYGEN
PASCAL
PRESSURE DROP OR DIFFERENCE
PHASE (ELECTRIC)
PRESSURE GAGE
OUTSIDE SCREW & YOKE
DIAMETER, OUTSIDE
PH
PG
Pa
PD
P
OXY
OS&Y
NTS
OA
OD
OAIL
SPR
SP
SPEC
SPDT
SM
SLPD
SLPS
SLPH
SEC
SF
SG
SH
SL
sprinkler
DRY-PIPE VALVE
PRE-ACTION VALVE
SIDEWALL SPRINKLER
ALARM CHECK VALVE
PENDENT SPRINKLER
UNION, SCREWED
UNION, FLANGED
TEE, SINGLE SWEEP
UPRIGHT SPRINKLER
COLD WATER
HOT WATER SUPPLY
HOT WATER RETURN
CONDENSATE DRAIN ABOVE
SANITARY DRAIN
ACID WASTE
CHEMICAL SUPPLY PIPES
FLOOR DRAIN
CONDENSATE DRAIN BELOW
FLOOR OR GRADE
FUNNEL DRAIN, OPEN
SURFACE CLEANOUT
VENT THRU ROOF
FLOOR CLEANOUT
PIPE SLEEVE
HOSE BIBB
BACKFLOW PREVENTER
PIPE SLEEVE WITH FIRE STOPPING
FLOOR SINK (200mm x 200mm)
PITCH OR PIPE, UP(U), DOWN(D)
FLOOR OR GRADE
(NAME)E
VAC
A
HWS
MTWR
HWR
MTWS
CR
CS
FOG
FOR
FOS
FOV
FOD
MU
VPD
PC
BBD
MPC
LPC
LPS
MPS
JWS
JWR
FCO
LOW TEMPERATURE HOT WATER RETURN
LOW TEMPERATURE HOT WATER SUPPLY
MEDIUM TEMPERATURE HOT WATER RETURN
MEDIUM TEMPERATURE HOT WATER SUPPLY
VACUUM (AIR)
COMPRESSED AIR
EXISTING PIPE
FUEL OIL RETURN
FUEL OIL SUPPLY
CONDENSATE WATER RETURN
CONDENSATE WATER SUPPLY
FUEL OIL GAUGE
PLAN ELEV.
BFP
200mm x 200mm
SCO
FUEL OIL TANK VENT
PUMPED CONDENSATE
BOILER BLOW DOWN
VACUUM PUMP DISCHARGE
FUEL OIL DRAIN
MAKE UP WATER
LOW PRESSURE STEAM
JACKET WATER SUPPLY
JACKET WATER RETURN
LOW PRESSURE CONDENSATE
MEDIUM PRESSURE CONDENSATE
MEDIUM PRESSURE STEAM
ACID
(NAME)
FD
CD
G GAS
CD
VENT
PIPING
heating plumbing
MOTOR ELECTRIC
CHECK, NON-SLAM
QUICK CLOSING, FUSIBLE LINK
SQUARE HEAD BALANCING COCK
PRESSURE REDUCING
SQUARE HEAD BALANCING COCK
HOSE END DRAIN
CONTROL, PNEUMATIC-ELECTRIC
CONTROL, ELECTRIC-PNEUMATIC
ALIGNMENT GUIDE
ANCHOR, INTERMEDIATE
AIR VENT, AUTOMATIC
AIR VENT, MANUAL
W/ MEASURING TAP
MV
AVV
S AIR SEPARATOR
S
R
SAFETY
QUICK OPENING
RELIEF
PE
LOCK SHIELD
NEEDLE
valves, special duty :
EP
M
S
CHECK, SWING
SOLENOID
DIAPHRAGM
LATERAL
TEE, OUTLET UP
REDUCER, CONCENTRIC
TEE
CONNECTION, TOP
ELBOW, TURNED UP
CONNECTION, BOTTOM
ELBOW, TURNED DOWN
fitting :
FLANGED
WELDED
R
SOLDERED
CAP
BUSHING
THERMOMETER
SCREWED
THERMOSTAT, ELECTRIC
valve actuators dampers
SQUARE
WATTHOUR OR WATER HEATER
HEAT TRANSFER COEFFICIENT
UNIT HEATER
URINAL
TEMPERATURE DIFFERENCE
TONS OF REFRIGERATION
THERMOMETER
THERMOSTAT
TYPICAL
THICKNESS
TEMPERATURE
SYMBOL
STAINLESS STEEL
SAYBOLT SECONDS FUROL
SAYBOLT SECONDS UNIVERSAL
STORAGE
SUCTION
STANDARD
STEEL
STEAM
WIDTH
WEIGHT
WASHER
WATERPROOF
WATER CLOSET
WATER-COOLED
W/
WT
WTRPRF
WSHR
WITH
WD
WH
WC
WCLD
FIRE DAMPER (PROVIDE ACCESS DOOR)
ELECTRIC MOTOR OPERATED DAMPER
SMOKE DAMPER (PROVIDE ACCESS DOOR)
PRESSURE, DYNAMIC(VELOCITY)
WET BULB TEMPERATURE
STATIC PRESSURE
LPD, STANDARD CONDITIONS
LPS, STANDARD CONDITIONS
LPH, STANDARD CONDITIONS
SINGLE POLE DOUBLE THROW
SPECIFICATION
SPRINKLER
SQUARE METER
SPECIFIC GRAVITY
SECOND
SAFETY FACTOR
SENSIBLE HEAT
SENSIBLE LOAD
VOLUME
VERTICAL
VISCOSITY
WET BULB
VENTILATION
WB
WBT
W
VP
WATT
VOL
VISC
VENT
VERT
VACUUM
VALVE
VARIABLE AIR VOLUME
VELOCITY
VOLTV
VAC
VLV
VAV
VEL
SD
AD
M
VD
AD FD
S
BDD
PNEUMATIC OPERATED DAMPER
SPLITTER DAMPER
BACKDRAFT DAMPER
MANUAL VOLUME DAMPER
DUCT SECTION, POSITIVE PRESS., FIRST
EXHAUST AIR GRILLE OR REGISTER, CEILING
DUCT SECTION, NEGATIVE PRESS., FIRST
ACCESS DOOR, VERTICAL OR HORIZONTAL
CHANGE OF ELEVATION, RISE(R), DOWN(D)
COWL, (GOOSENECK) AND FLASHING
F S
FC
TRANSITION
DETECTORS, FIRE AND/OR SMOKE
TURNING VANES
FLEXIBLE CONNECTION
SOUND ATTENUATOR
FLEXIBLE DUCT
AD
R
810mm x 400mm
810mm x 400mm
810mm x 400mm
FIGURE IS ON TOP
ACOUSTICAL LINING
DIRECTION OF FLOW
FIGURE IS ON TOP
(600mm x 300mmH, 472 LPS)
TG 600/300
NECK DIAMETER)
DIFFUSER, LINEAR
CEILING DIFFUSER, ROUND TYPE (200mm
CEILING DIFFUSER, SQUARE TYPE
EXISTING WORK TO BE REMOVED
200mm NCD
SUPPLY AIR GRILLE OR REGISTER, CEILING
EXHAUST AIR GRILLE OR REGISTER, CEILING
SUPPLY AIR GRILLE OR REGISTER, SIDEWALL
RETURN AIR GRILLE OR REGISTER, CEILING
TRANSFER GRILLE ASSEMBLY
LOUVER, DOOR OR WALL
UNDERCUT DOOR (13mm, 47.2 LPS)
DOOR GRILLE (300mmx150mmH)
(500mmWx300mmH, 94.4 LPS)
500/300L
47.2
UC 13mm
300x150
DG
94.4
SR
RR
RG
SG
EG
ER
SR
SG
DUCT WORK
grilles, registers and diffusers :
RLA
LRA
RATED LOAD AMPS
LOCKED ROTOR AMPS
REMOVE EXIST WORK(R)
(E) EXISTING WORK TO REMAIN.
OR END OF DEMOLITION WORK
POINT OF CONNECTION NEW TO EXISTING
SYMBOLS
MECHANICAL MATERIAL INDICATIONS &
(STORAGE S-247)
REPAIR OPERATION FACILITES IN AHA 23
M-2
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
GALVANIZED STEEL PIPE WITH CAST IRON DRAINAGE FITTINGS.
ABOVEGROUND VENT PIPING WILL BE HUBLESS CAST IRON PIPE AND FITTINGS OR
LAGGED COPPER PIPING. SOIL, WASTE, AND VENT PIPING WILL BE CAST IRON SOIL PIPE.
WITH TIN-ANTIMONY SOLDERED ENDS. HOT WATER PIPING WILL BE INSULATED AND
TYPE. WATER PIPING SHALL BE COPPER. FITTINGS SHALL BE CAST BRONZE OR COPPER
13. PLUMBING FIXTURES SHALL BE OF COMMERCIAL GRADE AND OF WATER CONSERVING
MAKING ALL NECESSARY DUCT CONNECTIONS FUNCTION AS ORIGINALLY INTENDED.
INSTALLATION, REMOVE THE EXISTING DUCTWORK AND REPLACE WITH NEW DUCTWORK,
EXISTING DUCTWORK ELEVATION AND LOCATION IS IN CONFLICT WITH THE NEW PIPING
MUST COORDINATE WITH THE EXISTING DUCTWORK ELEVATIONS AND LOCATION. IF THE
12. PRIOR TO THE INSTALLATION OF NEW HVAC AND PLUMBING PIPING, THE CONTRACTOR
CONTRACTING OFFICER FOR APPROVAL.
CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED TO THE
FIELD CONDITIONS. SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE
11. SOME DETAILS SHOWN ON THE CONTRACT DRAWINGS MAY NOT MATCH EXACTLY TO THE
SUCH AS ANCHORS, HANGERS/SUPPORTS, ETC.
10. ALL HVAC PIPING/DUCTWORK TO BE REMOVED SHALL INCLUDE ALL ITS ACCESSORIES,
PATCHED OR RESTORED TO MATCH THE ADJACENT SURFACE OR AREA.
9. ANY OPENING RESULT FROM THE REMOVAL WORK THAT IS NOT TO BE REUSED SHALL BE
DUCTWORK SHALL MEET THE REQUIREMENTS OF SEAL CLASS C.
ACCORDING TO SMACNA STATIC PRESSURE CONSTRUCTION CLASS 500PA AND
8. ALL SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED
AREA.
DUCTWORK SHALL BE PATCHED OR RESTORED TO MATCH THE ADJACENT SURFACE OR
7. ALL WALL/FLOOR/ROOF OPENINGS RESULTING FROM THE REMOVAL OF PIPING AND
SHOP DRAWING SHALL NOT BE THE EXACT DUPLICATION OF THE CONTRACT DRAWING.
6. NO MECHANICAL WORK CAN BE STARTED WITHOUT AN APPROVED SHOP DRAWING. A
5. CONCRETE REMOVAL AND RESTORATION SHALL CONFORM TO SPEC.
4. ANY PIPES THAT PENETRATE FIRE RATED WALLS (EXISTING/NEW) SHALL BE SEALED PER SPEC.
OR REPLACED BY THE CONTRACTOR.
DAMAGES DUE TO THE WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED
DAMAGE THE EXISTING EQUIPMENT, NEW EQUIPMENT, DUCTWORK, PIPING, ETC.
3. CONNECTIONS TO EXISTING SYSTEMS SHALL BE DONE IN SUCH A MANNER AS NOT TO
APPROXIMATE AND SHALL BE VERIFIED AT THE JOB SITE.
2. LOCATION AND SIZES OF EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. ARE
CORRECTIONS FOR THE CONTRACTING OFFICER'S APPROVAL.
CONTRACTING OFFICER'S REPRESENTATIVE WITH RECOMMENDATIONS FOR PROPER
DISCREPANCY IS DETECTED, IT SHOULD BE BROUGHT TO THE ATTENTION OF THE
EXISTING CONDITIONS, EQUIPMENT, FINISHES, ETC., PRIOR TO START OF WORK. IF ANY
1. THE CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH THE
GENERAL NOTES
GENERAL NOTES & SCOPE OF WORK
SCOPE OF WORK
REPAIR AND MAINTENANCE WORK (K-WORK)
GALVANIZED STEEL PIPE WITH CAST IRON DRAINAGE FITTINGS.
ABOVEGROUND VENT PIPING WILL BE HUBLESS CAST IRON PIPE AND FITTINGS OR
LAGGED COPPER PIPING. SOIL, WASTE, AND VENT PIPING WILL BE CAST IRON SOIL PIPE.
WITH TIN-ANTIMONY SOLDERED ENDS. HOT WATER PIPING WILL BE INSULATED AND
TYPE. WATER PIPING SHALL BE COPPER. FITTINGS SHALL BE CAST BRONZE OR COPPER
13. PLUMBING FIXTURES SHALL BE OF COMMERCIAL GRADE AND OF WATER CONSERVING
THE GROUNDING CONDUCTORS SHALL BE SEPARATELY PROVIDED FOR
MECHANICAL EQUIPMENT UNLESS OTHERWISE INDICATED ON THE DRAWING.
14.
15.
ALL ELECTRICAL WORK SHALL CONFORM TO THE CURRENT REQUIREMENTS
OF THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE,
FIRE CODE AND SPECIFICATIONS.
PROPER SIZE OF WIRE AND CONDUIT IN ACCORDANCE WITH MECHANICAL EQUIPMENT
SCHEDULE FOR GOVERNMENT APPROVAL PRIOR TO CONSTRUCTION.
16.
BLDG# S-247, CP CASEY
17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED AREA
INCLUDING SODDING, UTILITIES, STRUCTURES TO THEIR ORIGINAL CONDITION AND
OPERATION DURING AND AFTER INSTALLATION OF ELECTRICAL SYSTEM.
PURPOSE ONLY. CONTRACTOR SHALL VERIFY EXISITNG SITES CONDITION AND SUBMIT
SIZE AND COUNT OF WIRE, CONDUIT & ELECTRICAL DEVICES SHOWN ON DRAWING ARE ESTIMATED FOR BIDDING
1. REPAIR BY REPLACEMENT OF EXISTING ELECTRIC UNIT HEATER WITH NEW.
2. REPAIR BY REPLACEMENT OF EXISTING WALL EXHAUST FAN AND CONTROL WITH NEW.
3. REPAIR BY REPLACEMENT OF EXISTING LOUVER AND MOTORIZED DAMPER WITH NEW.
(STORAGE S-247)
REPAIR OPERATION FACILITES IN AHA 23
M-3
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M E C H A N I C A L E Q U I P M E N T S C H E D U L E
1 21115/1/60142
CENTRIFUGAL FAN
WALL MOUNTED, BELT DRIVEN,EF
1 3
R E M A R K SRPM
KW
(Pa)
ESP
(LPS)
AIR CAP
FAN MOTOR
VOLT/PH/HZ
W/ DISCONNECT SWITCH
BIRDSCREENW/ BACKDRAFT DAMPER
N O T ETYPES E R V I C EQ'TYITEM NO
DISCHARGE
HORIZONTAL
TYPE
120/1/601
EUH
POWER
HEATING ELEMENT CAP
VOLT/PH/HZ
REMARKSSERVICEQTYNO
ELECTRIC UNIT HEATER
T Y P E
MECH RM
ITEM FAN CAPACITY
RPM VOLT/PH/HZAIR CAP.
1,600 120/1/60
(KW) (LPS)
AND BUILT-IN THERMOSTAT.
PROVIDE UNIT MTD. DISCONNECT SWITCH.
189 6
WATTS
MOTOR
MECH ROOM
EXHAUST FANS
63 1,050 0.019 3
MECHANICAL EQUIPMENT SCHEDULE
(STORAGE S-247)
REPAIR OPERATION FACILITES IN AHA 23
M-4
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
SPECIFIC NOTES
M6
REMOVAL FLOOR PLAN(BLDG# S-247, CP CASEY)
SCALE : 1 / 100
AND SPECIFIC NOTES
(BLDG# S-247, CP CASEY)
REMOVAL FLOOR PLAN
STORAGE
OFFICE
MECH RM
EE/S
S/S
M
REMOVE EXISTING MOP SINK, ACCESSORIES AND ASSOCIATED PIPING.
REMOVE EXISTING SAFETY SHOWER & EYE WASH AND ASSOCIATED PIPING.
REMOVE EXISTING ALL EQUIPMENTS, ACCESSORIES AND ASSOCIATED PIPING IN MECH ROOM.
REMOVE EXISTING LOUVER AND MOTORIZED DAMPER .
REMAIN EXISTING HEAT PUMP SYSTEM.
(STORAGE S-247)
REPAIR OPERATION FACILITES IN AHA 23
M-5
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M6 SCALE : 1 / 100
(BLDG# S-247, CP CASEY)
HVAC FLOOR PLAN
STORAGE
OFFICE
MECH RM
M
EF
EUH
T
MOTORIZED DAMPER WITH LOUVER
(STORAGE S-247)
REPAIR OPERATION FACILITES IN AHA 23
CAMP CASEYCHONG, ST
HVAC FLOOR PLAN(BLDG# S-247, CP CASEY)
| 186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M1 |
| 186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M2 |
| 186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M3 |
| 186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M4 |
| 186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M5 |
| 186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M6 |
| 186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M7 |
| 186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M8 |
| 186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M9 |
| 186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M10 |
| 186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M11 |
| 186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M12 |
File details come from the government source that posted it.