Drawing_files___MECH_W91QVN18R0249.PDF

PDF 3 MB Posted

Attached to
Repair Operation Facilities in AHA No. 23
Solicitation number
W91QVN18R0249
Issued by

About this file

DRAWING - Mechanical

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

L E G E N D

M-1

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

BELL AND SPIGOT

TRAP, ELECTRIC (INDICATE TYPE)

SOLVENT CEMENT

REDUCER, ECCENTRIC (STRAIGHT, INVERT)

REDUCER, ECCENTRIC (STRAIGHT, DOWN)

FIRE DEPARTMENT CONNECTION

M E C H A N I C A L M A T E R I A L I N D I C A T I O N S & S Y M B O L S

TEE, OUTLET DOWN

ANCHOR, MAIN

BUTTERFLY

AIR LINE

valves : (for selective actuators)

GATE, ANGLE

PLUG VALVE

GATE, GLOBE

THREE WAY

CONTROL

DPT DEWPOINT TEMPERATUREAMERICAN WIRE GAUGEAWG

CENTIGRADE

CAPACITY

BRAKE HORSEPOWER

BAROMETER(-TRIC)

BOILING POINT

PRESSURE, BAROMETRIC

COOLING LOAD

COEFFICIENT

CUBIC METER PER HOUR

COUNTER CLOCKWISE

CLASSIFICATION

CAST IRON PIPE

CHILLED WATER

CIRCUIT

CUBIC METER

COMPRESSOR

CONTINUE

CONNECTIONCONN

CONT

CU M

CPRSR

CLASS

CLG LOAD

COEF

CMH

CKT

CIP

CHW

CCW

C

CAP

BP

BARO PR

BARO

BHP

FA FACE AREA OR FRESH AIR

FHC

FLA

FHY FIRE HYDRANT

FULL LOAD AMPERES

FIRE HOSE CABINET

EFF

EWT

EXPJT

EVAP

EP

EQPT

ESP

ENT

ECON

EDR

EAT

ECC

DX

DPDT

DPV

EFFICIENCY

EXPANSION JOINT

EXTERNAL STATIC PRESSURE

EVAPORAT (-E,-ING,-ED,-OR)

ENTERING WATER TEMP

EXPLOSION PROOF

ENTERING

EQUIPMENT

DRY PIPE VALVE

DOUBLE POLE DOUBLE THROW

ENTERING AIR TEMPERATURE

EQUIVALENT DIRECT RADIATION

DIRECT EXPANSION

ECONOMIZER

ECCENTRIC

air conditioning and refrigeration

AIR COOLED

ALARM CHECK VALVE

AIR CONDITION UNIT (S)

AVERAGE

APPROXIMATE

AMPERE(AMP, AMPS)

AIR HANDLING UNIT

ALTITUDE

AMBIENT

ALUMINUM

APPARATUS DEW POINT

AIR CONDITION (-ING,-ED)

AIR COOLED CONDENSING UNIT

APPROX

AVG

AMP

AMB

AIR COND

ALT

AL

AHU

ACCU

ACLD

ACU

ACV

ADP

C/HWS

C/HWR

CHS

CHR

D

RS

RL

RD

(NAME)

M

CU MM

DIAG

DO

DIV

DIFF

DB

DIA or

DBT

CW

Cv

CWP

DECIBEL OR DRY BULB

DRY BULB TEMPERATURE

DIAGRAM

DIVISION

DIESEL OIL

DIFFERENCE

DIAMETER

DEGREE

o

CUBIC MILLIMETER

COEFFICIENT, VALVE FLOW

CLOCKWISE OR COLD WATER

CIRCULATING WATER PUMP

HOT/CHILLED WATER SUPPLY

HOT CHILLED WATER RETURN

CHILLED WATER RETURN

CHILLED WATER SUPPLY

DRAIN

REFRIGERANT SUCTION

REFRIGERANT LIQUID

CONTROL AIR MAIN

PIPE TO BE REMOVED

REFRIGERANT DISCHARGE

GLOBE

GATE

A

BALL

SQ

PLUMBING

LIQUID LINELL

PLMB

LINEAR METER

LITERS PER DAY

LITERS PER HOUR

LAUNDRY TRAY

LITERS PER SECOND

LEAVING WATER TEMPERATURE

NOT APPLICABLE

NOISE CRITERIA

NORMALLY CLOSED

METERS PER SECOND

METERS PER HOUR

MINIMUM OR MINUTE

NORMALLY OPEN

NATIONAL TAPER PIPE (THREAD)

NOT IN CONTRACTNICKG KILOGRAM

KILOGRAM PER SQ. CENTIMETER (ABSOLUTE)

KILOGRAM PER SQ. CENTIMETER

KILOGRAM PER SQ. CENTIMETER (GAUGE)KG/SQ CM G

KG/SQ CM A

KG/SQ CM

NO

N.O.

NPT

NUMBER

KILOCALORIE PER HOUR

THERMAL CONDUCTIVITY

JOULE

IRON PIPE SIZE

ISOMETRIC

DIAMETER, INSIDE

KCAL/HR

K

J

ISO

ID

IPS

HEAD

HERTZ

HORIZONTAL

HORSEPOWER

HOT WATER

HOT WATER HEATER

HOUR(S)

MERCURY

HORIZ

HZ

HW

HWH

HP

HR

HD

HG

MAX MAXIMUM

NC

N/A

N.C.

MM

MPH

MPS

MIN

MILLIMETER

M

LT

LWT

LM

LPH

LPS

LPD

METERS

SUPPLY AIRSA

SANITARY

SUBMERSIBLE

SCHEDULE

SAN

SCH

SBM

UH

UR

U

QUART

QUANTITY

PERCENT

PETROLEUM, OIL AND LUBRICANTS

POINT OF CONNECTION

PARTS PER MILLION

PRESSURE REDUCING VALVE

RADIATOR

REFRIGERANT (12, 22, ETC)

REVOLUTIONS PER MINUTE

REFRIGERATION TON

THERMAL RESISTANCE

RETURN AIR

RELATIVE HUMIDITY

RT

RH

RPM

R12, R22

R

RA

RDTR

QT

QTY

PPM

PRV

POC

POL

THERM

TONS

TYP

THK

TSTAT

TD

TEMP

SYM

STOR

SUCT

STD

STL

SSU

SSF

SST

ST

FLEXIBLE CONNECTOR

EXPANSION JOINT

EXPANSION LOOP

FLOWMETER, ORIFICE

KILOGRAM PER SQ. METER (GAUGE)

KILOGRAM PER SQ. METER (ABSOLUTE)

KILOGRAM PER SQ. METER

STRAINER, BLOW OFF

PUMP (INDICATE USE)

PRESSURE GAUGE AND COCK

PRESSURE SWITCH

KILOWATT HOUR

LATENT HEAT

LEAVING AIR TEMPERATURE

FLOWMETER, VENTURI

A B B R E V I A T I O N S

FIBERGLASS REINFORCED PLASTIC

FEMALE PIPE THREAD

GRAMS

HOSE BIBB

FACE VELOCITY

FEED WATER PUMP

GAGE OR GAUGE

GALVANIZED STEEL

FIXTURE

GA

GALVS

HB

GR

FXTR

FVEL

FWP

FLUSH VALVE

FREQUENCY

FUEL OILFO

FREQ

FRP

FPT

FV

LAT

LH

LG

LBS

L

LAV

KWH

LENGTH

POUNDS

LITERS

LAVATORY

KG/SM G

KG/SM A

KG/SM

KJ

KW

KILOJOULE

KILOWATT

P

PS

FS

STRAINER

FLOW SWITCH

OFM

VFM

EJ

BALL JOINT

(2-WAY SHOWN)

OUTSIDE AIR

NOT TO SCALE

OUTSIDE AIR INTAKE LOUVER

POLE

OXYGEN

PASCAL

PRESSURE DROP OR DIFFERENCE

PHASE (ELECTRIC)

PRESSURE GAGE

OUTSIDE SCREW & YOKE

DIAMETER, OUTSIDE

PH

PG

Pa

PD

P

OXY

OS&Y

NTS

OA

OD

OAIL

SPR

SP

SPEC

SPDT

SM

SLPD

SLPS

SLPH

SEC

SF

SG

SH

SL

sprinkler

DRY-PIPE VALVE

PRE-ACTION VALVE

SIDEWALL SPRINKLER

ALARM CHECK VALVE

PENDENT SPRINKLER

UNION, SCREWED

UNION, FLANGED

TEE, SINGLE SWEEP

UPRIGHT SPRINKLER

COLD WATER

HOT WATER SUPPLY

HOT WATER RETURN

CONDENSATE DRAIN ABOVE

SANITARY DRAIN

ACID WASTE

CHEMICAL SUPPLY PIPES

FLOOR DRAIN

CONDENSATE DRAIN BELOW

FLOOR OR GRADE

FUNNEL DRAIN, OPEN

SURFACE CLEANOUT

VENT THRU ROOF

FLOOR CLEANOUT

PIPE SLEEVE

HOSE BIBB

BACKFLOW PREVENTER

PIPE SLEEVE WITH FIRE STOPPING

FLOOR SINK (200mm x 200mm)

PITCH OR PIPE, UP(U), DOWN(D)

FLOOR OR GRADE

(NAME)E

VAC

A

HWS

MTWR

HWR

MTWS

CR

CS

FOG

FOR

FOS

FOV

FOD

MU

VPD

PC

BBD

MPC

LPC

LPS

MPS

JWS

JWR

FCO

LOW TEMPERATURE HOT WATER RETURN

LOW TEMPERATURE HOT WATER SUPPLY

MEDIUM TEMPERATURE HOT WATER RETURN

MEDIUM TEMPERATURE HOT WATER SUPPLY

VACUUM (AIR)

COMPRESSED AIR

EXISTING PIPE

FUEL OIL RETURN

FUEL OIL SUPPLY

CONDENSATE WATER RETURN

CONDENSATE WATER SUPPLY

FUEL OIL GAUGE

PLAN ELEV.

BFP

200mm x 200mm

SCO

FUEL OIL TANK VENT

PUMPED CONDENSATE

BOILER BLOW DOWN

VACUUM PUMP DISCHARGE

FUEL OIL DRAIN

MAKE UP WATER

LOW PRESSURE STEAM

JACKET WATER SUPPLY

JACKET WATER RETURN

LOW PRESSURE CONDENSATE

MEDIUM PRESSURE CONDENSATE

MEDIUM PRESSURE STEAM

ACID

(NAME)

FD

CD

G GAS

CD

VENT

PIPING

heating plumbing

MOTOR ELECTRIC

CHECK, NON-SLAM

QUICK CLOSING, FUSIBLE LINK

SQUARE HEAD BALANCING COCK

PRESSURE REDUCING

SQUARE HEAD BALANCING COCK

HOSE END DRAIN

CONTROL, PNEUMATIC-ELECTRIC

CONTROL, ELECTRIC-PNEUMATIC

ALIGNMENT GUIDE

ANCHOR, INTERMEDIATE

AIR VENT, AUTOMATIC

AIR VENT, MANUAL

W/ MEASURING TAP

MV

AVV

S AIR SEPARATOR

S

R

SAFETY

QUICK OPENING

RELIEF

PE

LOCK SHIELD

NEEDLE

valves, special duty :

EP

M

S

CHECK, SWING

SOLENOID

DIAPHRAGM

LATERAL

TEE, OUTLET UP

REDUCER, CONCENTRIC

TEE

CONNECTION, TOP

ELBOW, TURNED UP

CONNECTION, BOTTOM

ELBOW, TURNED DOWN

fitting :

FLANGED

WELDED

R

SOLDERED

CAP

BUSHING

THERMOMETER

SCREWED

THERMOSTAT, ELECTRIC

valve actuators dampers

SQUARE

WATTHOUR OR WATER HEATER

HEAT TRANSFER COEFFICIENT

UNIT HEATER

URINAL

TEMPERATURE DIFFERENCE

TONS OF REFRIGERATION

THERMOMETER

THERMOSTAT

TYPICAL

THICKNESS

TEMPERATURE

SYMBOL

STAINLESS STEEL

SAYBOLT SECONDS FUROL

SAYBOLT SECONDS UNIVERSAL

STORAGE

SUCTION

STANDARD

STEEL

STEAM

WIDTH

WEIGHT

WASHER

WATERPROOF

WATER CLOSET

WATER-COOLED

W/

WT

WTRPRF

WSHR

WITH

WD

WH

WC

WCLD

FIRE DAMPER (PROVIDE ACCESS DOOR)

ELECTRIC MOTOR OPERATED DAMPER

SMOKE DAMPER (PROVIDE ACCESS DOOR)

PRESSURE, DYNAMIC(VELOCITY)

WET BULB TEMPERATURE

STATIC PRESSURE

LPD, STANDARD CONDITIONS

LPS, STANDARD CONDITIONS

LPH, STANDARD CONDITIONS

SINGLE POLE DOUBLE THROW

SPECIFICATION

SPRINKLER

SQUARE METER

SPECIFIC GRAVITY

SECOND

SAFETY FACTOR

SENSIBLE HEAT

SENSIBLE LOAD

VOLUME

VERTICAL

VISCOSITY

WET BULB

VENTILATION

WB

WBT

W

VP

WATT

VOL

VISC

VENT

VERT

VACUUM

VALVE

VARIABLE AIR VOLUME

VELOCITY

VOLTV

VAC

VLV

VAV

VEL

SD

AD

M

VD

AD FD

S

BDD

PNEUMATIC OPERATED DAMPER

SPLITTER DAMPER

BACKDRAFT DAMPER

MANUAL VOLUME DAMPER

DUCT SECTION, POSITIVE PRESS., FIRST

EXHAUST AIR GRILLE OR REGISTER, CEILING

DUCT SECTION, NEGATIVE PRESS., FIRST

ACCESS DOOR, VERTICAL OR HORIZONTAL

CHANGE OF ELEVATION, RISE(R), DOWN(D)

COWL, (GOOSENECK) AND FLASHING

F S

FC

TRANSITION

DETECTORS, FIRE AND/OR SMOKE

TURNING VANES

FLEXIBLE CONNECTION

SOUND ATTENUATOR

FLEXIBLE DUCT

AD

R

810mm x 400mm

810mm x 400mm

810mm x 400mm

FIGURE IS ON TOP

ACOUSTICAL LINING

DIRECTION OF FLOW

FIGURE IS ON TOP

(600mm x 300mmH, 472 LPS)

TG 600/300

NECK DIAMETER)

DIFFUSER, LINEAR

CEILING DIFFUSER, ROUND TYPE (200mm

CEILING DIFFUSER, SQUARE TYPE

EXISTING WORK TO BE REMOVED

200mm NCD

SUPPLY AIR GRILLE OR REGISTER, CEILING

EXHAUST AIR GRILLE OR REGISTER, CEILING

SUPPLY AIR GRILLE OR REGISTER, SIDEWALL

RETURN AIR GRILLE OR REGISTER, CEILING

TRANSFER GRILLE ASSEMBLY

LOUVER, DOOR OR WALL

UNDERCUT DOOR (13mm, 47.2 LPS)

DOOR GRILLE (300mmx150mmH)

(500mmWx300mmH, 94.4 LPS)

500/300L

47.2

UC 13mm

300x150

DG

94.4

SR

RR

RG

SG

EG

ER

SR

SG

DUCT WORK

grilles, registers and diffusers :

RLA

LRA

RATED LOAD AMPS

LOCKED ROTOR AMPS

REMOVE EXIST WORK(R)

(E) EXISTING WORK TO REMAIN.

OR END OF DEMOLITION WORK

POINT OF CONNECTION NEW TO EXISTING

SYMBOLS

MECHANICAL MATERIAL INDICATIONS &

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYCHONG, ST

186681

M-2

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

GALVANIZED STEEL PIPE WITH CAST IRON DRAINAGE FITTINGS.

ABOVEGROUND VENT PIPING WILL BE HUBLESS CAST IRON PIPE AND FITTINGS OR

LAGGED COPPER PIPING. SOIL, WASTE, AND VENT PIPING WILL BE CAST IRON SOIL PIPE.

WITH TIN-ANTIMONY SOLDERED ENDS. HOT WATER PIPING WILL BE INSULATED AND

TYPE. WATER PIPING SHALL BE COPPER. FITTINGS SHALL BE CAST BRONZE OR COPPER

13. PLUMBING FIXTURES SHALL BE OF COMMERCIAL GRADE AND OF WATER CONSERVING

MAKING ALL NECESSARY DUCT CONNECTIONS FUNCTION AS ORIGINALLY INTENDED.

INSTALLATION, REMOVE THE EXISTING DUCTWORK AND REPLACE WITH NEW DUCTWORK,

EXISTING DUCTWORK ELEVATION AND LOCATION IS IN CONFLICT WITH THE NEW PIPING

MUST COORDINATE WITH THE EXISTING DUCTWORK ELEVATIONS AND LOCATION. IF THE

12. PRIOR TO THE INSTALLATION OF NEW HVAC AND PLUMBING PIPING, THE CONTRACTOR

CONTRACTING OFFICER FOR APPROVAL.

CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED TO THE

FIELD CONDITIONS. SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE

11. SOME DETAILS SHOWN ON THE CONTRACT DRAWINGS MAY NOT MATCH EXACTLY TO THE

SUCH AS ANCHORS, HANGERS/SUPPORTS, ETC.

10. ALL HVAC PIPING/DUCTWORK TO BE REMOVED SHALL INCLUDE ALL ITS ACCESSORIES,

PATCHED OR RESTORED TO MATCH THE ADJACENT SURFACE OR AREA.

9. ANY OPENING RESULT FROM THE REMOVAL WORK THAT IS NOT TO BE REUSED SHALL BE

DUCTWORK SHALL MEET THE REQUIREMENTS OF SEAL CLASS C.

ACCORDING TO SMACNA STATIC PRESSURE CONSTRUCTION CLASS 500PA AND

8. ALL SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED

AREA.

DUCTWORK SHALL BE PATCHED OR RESTORED TO MATCH THE ADJACENT SURFACE OR

7. ALL WALL/FLOOR/ROOF OPENINGS RESULTING FROM THE REMOVAL OF PIPING AND

SHOP DRAWING SHALL NOT BE THE EXACT DUPLICATION OF THE CONTRACT DRAWING.

6. NO MECHANICAL WORK CAN BE STARTED WITHOUT AN APPROVED SHOP DRAWING. A

5. CONCRETE REMOVAL AND RESTORATION SHALL CONFORM TO SPEC.

4. ANY PIPES THAT PENETRATE FIRE RATED WALLS (EXISTING/NEW) SHALL BE SEALED PER SPEC.

OR REPLACED BY THE CONTRACTOR.

DAMAGES DUE TO THE WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED

DAMAGE THE EXISTING EQUIPMENT, NEW EQUIPMENT, DUCTWORK, PIPING, ETC.

3. CONNECTIONS TO EXISTING SYSTEMS SHALL BE DONE IN SUCH A MANNER AS NOT TO

APPROXIMATE AND SHALL BE VERIFIED AT THE JOB SITE.

2. LOCATION AND SIZES OF EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. ARE

CORRECTIONS FOR THE CONTRACTING OFFICER'S APPROVAL.

CONTRACTING OFFICER'S REPRESENTATIVE WITH RECOMMENDATIONS FOR PROPER

DISCREPANCY IS DETECTED, IT SHOULD BE BROUGHT TO THE ATTENTION OF THE

EXISTING CONDITIONS, EQUIPMENT, FINISHES, ETC., PRIOR TO START OF WORK. IF ANY

1. THE CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH THE

GENERAL NOTES

GENERAL NOTES & SCOPE OF WORK

SCOPE OF WORK

REPAIR AND MAINTENANCE WORK (K-WORK)

GALVANIZED STEEL PIPE WITH CAST IRON DRAINAGE FITTINGS.

ABOVEGROUND VENT PIPING WILL BE HUBLESS CAST IRON PIPE AND FITTINGS OR

LAGGED COPPER PIPING. SOIL, WASTE, AND VENT PIPING WILL BE CAST IRON SOIL PIPE.

WITH TIN-ANTIMONY SOLDERED ENDS. HOT WATER PIPING WILL BE INSULATED AND

TYPE. WATER PIPING SHALL BE COPPER. FITTINGS SHALL BE CAST BRONZE OR COPPER

13. PLUMBING FIXTURES SHALL BE OF COMMERCIAL GRADE AND OF WATER CONSERVING

THE GROUNDING CONDUCTORS SHALL BE SEPARATELY PROVIDED FOR

MECHANICAL EQUIPMENT UNLESS OTHERWISE INDICATED ON THE DRAWING.

14.

15.

ALL ELECTRICAL WORK SHALL CONFORM TO THE CURRENT REQUIREMENTS

OF THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE,

FIRE CODE AND SPECIFICATIONS.

PROPER SIZE OF WIRE AND CONDUIT IN ACCORDANCE WITH MECHANICAL EQUIPMENT

SCHEDULE FOR GOVERNMENT APPROVAL PRIOR TO CONSTRUCTION.

16.

BLDG# S-246, CP CASEY

1. REPAIR BY REPLACEMENT OF EXISTING OIL TYPE DOMESTIC HOT WATER HEATER WITH ELECTRIC TYPE

DOMESTIC HOT WATER HEATER AND ASSOCIATED PIPING.

17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED AREA

INCLUDING SODDING, UTILITIES, STRUCTURES TO THEIR ORIGINAL CONDITION AND

OPERATION DURING AND AFTER INSTALLATION OF ELECTRICAL SYSTEM.

PURPOSE ONLY. CONTRACTOR SHALL VERIFY EXISITNG SITES CONDITION AND SUBMIT

SIZE AND COUNT OF WIRE, CONDUIT & ELECTRICAL DEVICES SHOWN ON DRAWING ARE ESTIMATED FOR BIDDING

2. REPAIR BY REPLACEMENT OF EXISTING ELECTRIC UNIT HEATER WITH NEW.

3. REPAIR BY REPLACEMENT OF EXISTING ROOF EXHAUST FAN, CEILLING FANS, CONTROL AND ASSOCIATED DUCTS WITH NEW.

5. REMOVE EXISTING FUEL OIL STORAGE TANK, DIKE AND ASSOCIATED OIL PIPING.

4. REMOVE AND REINSTALL EXISTING HEAT PUMP SYSTEM, CONTROL AND ASSOCIATED PIPING.

6. REPAIR BY REPLACEMENT OF EXISTING PLUMBING FIXTURES AND ASSOCIATED HW, CW, SEWER, VENT PIPING WITH NEW.

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

M-3

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

ROUND VERTICAL TYPE

TEMP.

SUPPLYSTORAGE

CAPACITY

T Y P E

ELEMENT CAPACITY

REMARKS

43.3208/3/60

LOWER: 3.5 KW

KW (DEG. C)VOLT/PH/HZ(LITS)

SERVICEITEM NO QTY

TOILET RM.1

ELECTRIC HOT WATER HEATER

EWH

1 UPPER: 3.5 KW

M E C H A N I C A L E Q U I P M E N T S C H E D U L E

1 21115/1/60142

CENTRIFUGAL FAN

ROOF MOUNTED, BELT DRIVEN,

EF

EF

R E M A R K SRPM

KW

(Pa)

ESP

(LPS)

AIR CAP

FAN MOTOR

VOLT/PH/HZ

W/ DISCONNECT SWITCH

BIRDSCREENW/ BACKDRAFT DAMPER

N O T ETYPES E R V I C EQ'TYITEM NO

1 4DIRECT DRIVEN, CENTRIFUGAL FAN

DISCHARGE

HORIZONTAL

TYPE

120/1/601

EUH

POWER

HEATING ELEMENT CAP

VOLT/PH/HZ

REMARKSSERVICEQTYNO

ELECTRIC UNIT HEATER

T Y P E

MECH RM

ITEM FAN CAPACITY

RPM VOLT/PH/HZAIR CAP.

1,600 120/1/60

(KW) (LPS)

AND BUILT-IN THERMOSTAT.

PROVIDE UNIT MTD. DISCONNECT SWITCH.

113 NON-SMULTANOUS OPERATION

189 6

WATTS

MOTOR

MECH ROOM

TOILET

EXHAUST FANS

CEILING MOUNTED,

1,050

115/1/60

0.025

0.018 CEILING GRILLE

MECHANICAL EQUIPMENT SCHEDULE

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

M-4

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

SPECIFIC NOTES

M6

FEC

OFFICE

OFFICE

VEST

OFFICE

SENTRY

AREA

VISITOR

ROOM

LOUNGE

TOILET

MEN

TOILET

WOMEN

OFFICE

CORRIDOR

ROOM

MECH

REMOVE EXISTING ALL FAN COIL UNITS ASSOCIATED PIPING.

1 1 1

REMOVE EXISTING ALL HVAC & PLUMBING PIPING.

REMOVE EXISTING ALL EQUIPMENTS AND ASSOCIATED PIPING IN MECH ROOM.

4 REMOVE EXISTING ALL EQUIPMENTS, PLUMBING FIXTURES AND ASSOCIATED PIPING IN TOILET.

RETURN FUEL TANK TO DPW WITH FUEL OIL TANK CLEANING IAW KOREA ENVIRONMENTAL LAW.

REMOVE EXISTING FUEL OIL STORAGE TANK, DIKE AND OIL PIPING. RESTORE GROUND CONDITION SAME AS ADJACENT AREA.

REMOVE AND REISTALL EXISTING ALL HEAT PUMP SYSTEM, CONTROL AND ASSOCIATED PIPING.

REMOVAL FLOOR PLAN(BLDG# S-246, CP CASEY)

SCALE : 1 / 100

AND SPECIFIC NOTES

(BLDG# S-246, CP CASEY)

REMOVAL FLOOR PLAN

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYCHONG, ST

M-5

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

M6

FEC

OFFICE

OFFICE

VEST

OFFICE

SENTRY

AREA

VISITOR

ROOM

LOUNGE

TOILET

MEN

TOILET

WOMEN

OFFICE

CORRIDOR

ROOM

MECH

EF

EF

EF

EUH

EWH

SCALE : 1 / 100

SEE

-M6

(BLDG# S-246, CP CASEY)

HVAC FLOOR PLAN

T

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYCHONG, ST

HVAC FLOOR PLAN(BLDG# S-246, CP CASEY)

M-6

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

M6

FEC

TOILET

MEN

TOILET

WOMEN

ROOM

MECH

EWH

POC

WATER HAMMER ARRESTOR

(PDI:"A" TYPE)

WATER HAMMER ARRESTOR

(PDI:"A" TYPE)

WATER HAMMER ARRESTOR

(PDI:"A" TYPE)

WATER HAMMER ARRESTOR

(PDI:"A" TYPE)

RESPONSIBLE FOR VERIFYING ACTUAL QUANTITIES BASED ON THE CONTRACT DOCUMENTS

1. QUANTITIES ARE SHOWN FOR ESTIMATION PURPOSE ONLY, THE CONTRACTOR SHALL BENOTES :

REQUIREMENTS.

FLUSH VALVE WALL HUNG TYPE

WASTE

PIPE CONNECTION

H.W. VENT

BACK

R E M A R K S

C.W.

QTY.

P-1

P-5

SYMBOL

F I X T U R E

LAVATORY

WATER CLOSET2

COUNTER TOP.

20P-3 URINAL1 - 40 50

P-1

P-1

P-5 P-5

P-3

1 KITCHEN SINK

STANLESS STEEL TYPE50401515

FLUSH TANK TYPE

1.

NOTES:

CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION

2.

OF HW, CW, SEWER AND VENT PIPING IN FIELD(TYP)

(HOT & COLD WATER PIPING, SEWER AND VENT PIPING)

CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR PLUMBING PIPING

PRIOR TO HOT, COLD, SEWER, VENT PIPING INSTALLATION.

SCALE : 1 / 100

P-7

P-7

Q' TY

WATER HAMMER ARRESTER SCHEDULE

FIXTURE

UNIT RATING

CONN.

SIZE

P.D.I

SYMBOL

REMARK

1 - 11A

( TYPICAL )

12 - 32B

15 mm

20 mm COMPRESSION CHAMBER WITH EXPANSION

STAINLESS STEEL CONSTRUCTION PRESSURIZED

PLUMBING FIXTURE SCHEDULE

AND WATER HAMMER ARRESTER SCH.

PLUMBING FIXTURE SCHEDULE, NOTES

(BLDG# S-246, CP CASEY)

PLUMBING PARTIAL FLOOR PLAN

T

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYCHONG, ST

PLUMBING PARTIAL FLOOR PLAN(BLDG# S-246, CP CASEY)

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

M-7

MECHANICAL

DIVISION 7 WORK

BACKDRAFT MOTORIZED

INSULATED ROOF CURVE,

EXHAUST DUCT WORK

POWER ROOF VENTILATOR

POWER ROOF VENTILATOR

MIN. 2 EACH SIDE

BY FAN MFR.,

RECOMMENDED

LAGBOLTS AS

CURB HT.

300 MIN.

SEE ARCH. DWGS.

WOOD BLOCKING,

SEE ARCH. DWGS.

ROOF CONSTR.

SEE ARCH. DWGS.

WOOD NAILER

ALL AROUND

GASKET SEAL

(SPECIFIED IN DIVISION 7)

FLASHING

UNIT HOOD

M

DAMPER

MOTOR

DAMPER

ELECTRIC WATER HEATER

COMBINATION TEMPERATURE

AND PRESSURE RELIEF VALVE

BALL VALVE

SHALL BE 150 LARGER

DRAIN PAN

THAN WATER HEATER

VACUUM BREAKER

ELECTRIC WATER

BALL VALVE

COLD WATER

SERVICE LINE

32HOT WATER

SUPPLY LINE

THAN DRAIN PAN

NOTE :

IN CLG. SPACE

HEATER SUSPENDED

INSTALL WATER HEATER 100HIGHER

DOWN AND DISCHARGE

TO THE NEAREST FLOOR DRAIN

FULL SIZE DRAIN PIPE

NEAREST FLOOR DRAIN

DISCHARGE TO THE

15DRAIN VALVE

"C"

"A"

"B"

TYPE

33-60128 125

WATER HAMMER ARRESTOR

94 81

115 81

HEIGHT DIAMETER

1-11

12-32

CAPACITY

FIXTURE UNIT

FIXTURE

TO LAST

THREADED PLUG

FROM BRANCH

SUPPLY

AND SIZE

20 OR 25 SEE

DWGS FOR LOCATION

PRESSURE PNEUMATIC

STAINLESS STEELSHELL

STAINLESS STEEL

ORIFICE

FLOW CONTROL

H E

IG

H

T DISPLACEMENT

ADAPTER

FLUID

BELLOWS

HYDRAULIC

CUSHION

DISPLACEMENT

DIAMETER

-M7 M7 M7

DETAILS

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

L E G E N D

M-1

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

BELL AND SPIGOT

TRAP, ELECTRIC (INDICATE TYPE)

SOLVENT CEMENT

REDUCER, ECCENTRIC (STRAIGHT, INVERT)

REDUCER, ECCENTRIC (STRAIGHT, DOWN)

FIRE DEPARTMENT CONNECTION

M E C H A N I C A L M A T E R I A L I N D I C A T I O N S & S Y M B O L S

TEE, OUTLET DOWN

ANCHOR, MAIN

BUTTERFLY

AIR LINE

valves : (for selective actuators)

GATE, ANGLE

PLUG VALVE

GATE, GLOBE

THREE WAY

CONTROL

DPT DEWPOINT TEMPERATUREAMERICAN WIRE GAUGEAWG

CENTIGRADE

CAPACITY

BRAKE HORSEPOWER

BAROMETER(-TRIC)

BOILING POINT

PRESSURE, BAROMETRIC

COOLING LOAD

COEFFICIENT

CUBIC METER PER HOUR

COUNTER CLOCKWISE

CLASSIFICATION

CAST IRON PIPE

CHILLED WATER

CIRCUIT

CUBIC METER

COMPRESSOR

CONTINUE

CONNECTIONCONN

CONT

CU M

CPRSR

CLASS

CLG LOAD

COEF

CMH

CKT

CIP

CHW

CCW

C

CAP

BP

BARO PR

BARO

BHP

FA FACE AREA OR FRESH AIR

FHC

FLA

FHY FIRE HYDRANT

FULL LOAD AMPERES

FIRE HOSE CABINET

EFF

EWT

EXPJT

EVAP

EP

EQPT

ESP

ENT

ECON

EDR

EAT

ECC

DX

DPDT

DPV

EFFICIENCY

EXPANSION JOINT

EXTERNAL STATIC PRESSURE

EVAPORAT (-E,-ING,-ED,-OR)

ENTERING WATER TEMP

EXPLOSION PROOF

ENTERING

EQUIPMENT

DRY PIPE VALVE

DOUBLE POLE DOUBLE THROW

ENTERING AIR TEMPERATURE

EQUIVALENT DIRECT RADIATION

DIRECT EXPANSION

ECONOMIZER

ECCENTRIC

air conditioning and refrigeration

AIR COOLED

ALARM CHECK VALVE

AIR CONDITION UNIT (S)

AVERAGE

APPROXIMATE

AMPERE(AMP, AMPS)

AIR HANDLING UNIT

ALTITUDE

AMBIENT

ALUMINUM

APPARATUS DEW POINT

AIR CONDITION (-ING,-ED)

AIR COOLED CONDENSING UNIT

APPROX

AVG

AMP

AMB

AIR COND

ALT

AL

AHU

ACCU

ACLD

ACU

ACV

ADP

C/HWS

C/HWR

CHS

CHR

D

RS

RL

RD

(NAME)

M

CU MM

DIAG

DO

DIV

DIFF

DB

DIA or

DBT

CW

Cv

CWP

DECIBEL OR DRY BULB

DRY BULB TEMPERATURE

DIAGRAM

DIVISION

DIESEL OIL

DIFFERENCE

DIAMETER

DEGREE

o

CUBIC MILLIMETER

COEFFICIENT, VALVE FLOW

CLOCKWISE OR COLD WATER

CIRCULATING WATER PUMP

HOT/CHILLED WATER SUPPLY

HOT CHILLED WATER RETURN

CHILLED WATER RETURN

CHILLED WATER SUPPLY

DRAIN

REFRIGERANT SUCTION

REFRIGERANT LIQUID

CONTROL AIR MAIN

PIPE TO BE REMOVED

REFRIGERANT DISCHARGE

GLOBE

GATE

A

BALL

SQ

PLUMBING

LIQUID LINELL

PLMB

LINEAR METER

LITERS PER DAY

LITERS PER HOUR

LAUNDRY TRAY

LITERS PER SECOND

LEAVING WATER TEMPERATURE

NOT APPLICABLE

NOISE CRITERIA

NORMALLY CLOSED

METERS PER SECOND

METERS PER HOUR

MINIMUM OR MINUTE

NORMALLY OPEN

NATIONAL TAPER PIPE (THREAD)

NOT IN CONTRACTNICKG KILOGRAM

KILOGRAM PER SQ. CENTIMETER (ABSOLUTE)

KILOGRAM PER SQ. CENTIMETER

KILOGRAM PER SQ. CENTIMETER (GAUGE)KG/SQ CM G

KG/SQ CM A

KG/SQ CM

NO

N.O.

NPT

NUMBER

KILOCALORIE PER HOUR

THERMAL CONDUCTIVITY

JOULE

IRON PIPE SIZE

ISOMETRIC

DIAMETER, INSIDE

KCAL/HR

K

J

ISO

ID

IPS

HEAD

HERTZ

HORIZONTAL

HORSEPOWER

HOT WATER

HOT WATER HEATER

HOUR(S)

MERCURY

HORIZ

HZ

HW

HWH

HP

HR

HD

HG

MAX MAXIMUM

NC

N/A

N.C.

MM

MPH

MPS

MIN

MILLIMETER

M

LT

LWT

LM

LPH

LPS

LPD

METERS

SUPPLY AIRSA

SANITARY

SUBMERSIBLE

SCHEDULE

SAN

SCH

SBM

UH

UR

U

QUART

QUANTITY

PERCENT

PETROLEUM, OIL AND LUBRICANTS

POINT OF CONNECTION

PARTS PER MILLION

PRESSURE REDUCING VALVE

RADIATOR

REFRIGERANT (12, 22, ETC)

REVOLUTIONS PER MINUTE

REFRIGERATION TON

THERMAL RESISTANCE

RETURN AIR

RELATIVE HUMIDITY

RT

RH

RPM

R12, R22

R

RA

RDTR

QT

QTY

PPM

PRV

POC

POL

THERM

TONS

TYP

THK

TSTAT

TD

TEMP

SYM

STOR

SUCT

STD

STL

SSU

SSF

SST

ST

FLEXIBLE CONNECTOR

EXPANSION JOINT

EXPANSION LOOP

FLOWMETER, ORIFICE

KILOGRAM PER SQ. METER (GAUGE)

KILOGRAM PER SQ. METER (ABSOLUTE)

KILOGRAM PER SQ. METER

STRAINER, BLOW OFF

PUMP (INDICATE USE)

PRESSURE GAUGE AND COCK

PRESSURE SWITCH

KILOWATT HOUR

LATENT HEAT

LEAVING AIR TEMPERATURE

FLOWMETER, VENTURI

A B B R E V I A T I O N S

FIBERGLASS REINFORCED PLASTIC

FEMALE PIPE THREAD

GRAMS

HOSE BIBB

FACE VELOCITY

FEED WATER PUMP

GAGE OR GAUGE

GALVANIZED STEEL

FIXTURE

GA

GALVS

HB

GR

FXTR

FVEL

FWP

FLUSH VALVE

FREQUENCY

FUEL OILFO

FREQ

FRP

FPT

FV

LAT

LH

LG

LBS

L

LAV

KWH

LENGTH

POUNDS

LITERS

LAVATORY

KG/SM G

KG/SM A

KG/SM

KJ

KW

KILOJOULE

KILOWATT

P

PS

FS

STRAINER

FLOW SWITCH

OFM

VFM

EJ

BALL JOINT

(2-WAY SHOWN)

OUTSIDE AIR

NOT TO SCALE

OUTSIDE AIR INTAKE LOUVER

POLE

OXYGEN

PASCAL

PRESSURE DROP OR DIFFERENCE

PHASE (ELECTRIC)

PRESSURE GAGE

OUTSIDE SCREW & YOKE

DIAMETER, OUTSIDE

PH

PG

Pa

PD

P

OXY

OS&Y

NTS

OA

OD

OAIL

SPR

SP

SPEC

SPDT

SM

SLPD

SLPS

SLPH

SEC

SF

SG

SH

SL

sprinkler

DRY-PIPE VALVE

PRE-ACTION VALVE

SIDEWALL SPRINKLER

ALARM CHECK VALVE

PENDENT SPRINKLER

UNION, SCREWED

UNION, FLANGED

TEE, SINGLE SWEEP

UPRIGHT SPRINKLER

COLD WATER

HOT WATER SUPPLY

HOT WATER RETURN

CONDENSATE DRAIN ABOVE

SANITARY DRAIN

ACID WASTE

CHEMICAL SUPPLY PIPES

FLOOR DRAIN

CONDENSATE DRAIN BELOW

FLOOR OR GRADE

FUNNEL DRAIN, OPEN

SURFACE CLEANOUT

VENT THRU ROOF

FLOOR CLEANOUT

PIPE SLEEVE

HOSE BIBB

BACKFLOW PREVENTER

PIPE SLEEVE WITH FIRE STOPPING

FLOOR SINK (200mm x 200mm)

PITCH OR PIPE, UP(U), DOWN(D)

FLOOR OR GRADE

(NAME)E

VAC

A

HWS

MTWR

HWR

MTWS

CR

CS

FOG

FOR

FOS

FOV

FOD

MU

VPD

PC

BBD

MPC

LPC

LPS

MPS

JWS

JWR

FCO

LOW TEMPERATURE HOT WATER RETURN

LOW TEMPERATURE HOT WATER SUPPLY

MEDIUM TEMPERATURE HOT WATER RETURN

MEDIUM TEMPERATURE HOT WATER SUPPLY

VACUUM (AIR)

COMPRESSED AIR

EXISTING PIPE

FUEL OIL RETURN

FUEL OIL SUPPLY

CONDENSATE WATER RETURN

CONDENSATE WATER SUPPLY

FUEL OIL GAUGE

PLAN ELEV.

BFP

200mm x 200mm

SCO

FUEL OIL TANK VENT

PUMPED CONDENSATE

BOILER BLOW DOWN

VACUUM PUMP DISCHARGE

FUEL OIL DRAIN

MAKE UP WATER

LOW PRESSURE STEAM

JACKET WATER SUPPLY

JACKET WATER RETURN

LOW PRESSURE CONDENSATE

MEDIUM PRESSURE CONDENSATE

MEDIUM PRESSURE STEAM

ACID

(NAME)

FD

CD

G GAS

CD

VENT

PIPING

heating plumbing

MOTOR ELECTRIC

CHECK, NON-SLAM

QUICK CLOSING, FUSIBLE LINK

SQUARE HEAD BALANCING COCK

PRESSURE REDUCING

SQUARE HEAD BALANCING COCK

HOSE END DRAIN

CONTROL, PNEUMATIC-ELECTRIC

CONTROL, ELECTRIC-PNEUMATIC

ALIGNMENT GUIDE

ANCHOR, INTERMEDIATE

AIR VENT, AUTOMATIC

AIR VENT, MANUAL

W/ MEASURING TAP

MV

AVV

S AIR SEPARATOR

S

R

SAFETY

QUICK OPENING

RELIEF

PE

LOCK SHIELD

NEEDLE

valves, special duty :

EP

M

S

CHECK, SWING

SOLENOID

DIAPHRAGM

LATERAL

TEE, OUTLET UP

REDUCER, CONCENTRIC

TEE

CONNECTION, TOP

ELBOW, TURNED UP

CONNECTION, BOTTOM

ELBOW, TURNED DOWN

fitting :

FLANGED

WELDED

R

SOLDERED

CAP

BUSHING

THERMOMETER

SCREWED

THERMOSTAT, ELECTRIC

valve actuators dampers

SQUARE

WATTHOUR OR WATER HEATER

HEAT TRANSFER COEFFICIENT

UNIT HEATER

URINAL

TEMPERATURE DIFFERENCE

TONS OF REFRIGERATION

THERMOMETER

THERMOSTAT

TYPICAL

THICKNESS

TEMPERATURE

SYMBOL

STAINLESS STEEL

SAYBOLT SECONDS FUROL

SAYBOLT SECONDS UNIVERSAL

STORAGE

SUCTION

STANDARD

STEEL

STEAM

WIDTH

WEIGHT

WASHER

WATERPROOF

WATER CLOSET

WATER-COOLED

W/

WT

WTRPRF

WSHR

WITH

WD

WH

WC

WCLD

FIRE DAMPER (PROVIDE ACCESS DOOR)

ELECTRIC MOTOR OPERATED DAMPER

SMOKE DAMPER (PROVIDE ACCESS DOOR)

PRESSURE, DYNAMIC(VELOCITY)

WET BULB TEMPERATURE

STATIC PRESSURE

LPD, STANDARD CONDITIONS

LPS, STANDARD CONDITIONS

LPH, STANDARD CONDITIONS

SINGLE POLE DOUBLE THROW

SPECIFICATION

SPRINKLER

SQUARE METER

SPECIFIC GRAVITY

SECOND

SAFETY FACTOR

SENSIBLE HEAT

SENSIBLE LOAD

VOLUME

VERTICAL

VISCOSITY

WET BULB

VENTILATION

WB

WBT

W

VP

WATT

VOL

VISC

VENT

VERT

VACUUM

VALVE

VARIABLE AIR VOLUME

VELOCITY

VOLTV

VAC

VLV

VAV

VEL

SD

AD

M

VD

AD FD

S

BDD

PNEUMATIC OPERATED DAMPER

SPLITTER DAMPER

BACKDRAFT DAMPER

MANUAL VOLUME DAMPER

DUCT SECTION, POSITIVE PRESS., FIRST

EXHAUST AIR GRILLE OR REGISTER, CEILING

DUCT SECTION, NEGATIVE PRESS., FIRST

ACCESS DOOR, VERTICAL OR HORIZONTAL

CHANGE OF ELEVATION, RISE(R), DOWN(D)

COWL, (GOOSENECK) AND FLASHING

F S

FC

TRANSITION

DETECTORS, FIRE AND/OR SMOKE

TURNING VANES

FLEXIBLE CONNECTION

SOUND ATTENUATOR

FLEXIBLE DUCT

AD

R

810mm x 400mm

810mm x 400mm

810mm x 400mm

FIGURE IS ON TOP

ACOUSTICAL LINING

DIRECTION OF FLOW

FIGURE IS ON TOP

(600mm x 300mmH, 472 LPS)

TG 600/300

NECK DIAMETER)

DIFFUSER, LINEAR

CEILING DIFFUSER, ROUND TYPE (200mm

CEILING DIFFUSER, SQUARE TYPE

EXISTING WORK TO BE REMOVED

200mm NCD

SUPPLY AIR GRILLE OR REGISTER, CEILING

EXHAUST AIR GRILLE OR REGISTER, CEILING

SUPPLY AIR GRILLE OR REGISTER, SIDEWALL

RETURN AIR GRILLE OR REGISTER, CEILING

TRANSFER GRILLE ASSEMBLY

LOUVER, DOOR OR WALL

UNDERCUT DOOR (13mm, 47.2 LPS)

DOOR GRILLE (300mmx150mmH)

(500mmWx300mmH, 94.4 LPS)

500/300L

47.2

UC 13mm

300x150

DG

94.4

SR

RR

RG

SG

EG

ER

SR

SG

DUCT WORK

grilles, registers and diffusers :

RLA

LRA

RATED LOAD AMPS

LOCKED ROTOR AMPS

REMOVE EXIST WORK(R)

(E) EXISTING WORK TO REMAIN.

OR END OF DEMOLITION WORK

POINT OF CONNECTION NEW TO EXISTING

SYMBOLS

MECHANICAL MATERIAL INDICATIONS &

(STORAGE S-247)

REPAIR OPERATION FACILITES IN AHA 23

M-2

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

GALVANIZED STEEL PIPE WITH CAST IRON DRAINAGE FITTINGS.

ABOVEGROUND VENT PIPING WILL BE HUBLESS CAST IRON PIPE AND FITTINGS OR

LAGGED COPPER PIPING. SOIL, WASTE, AND VENT PIPING WILL BE CAST IRON SOIL PIPE.

WITH TIN-ANTIMONY SOLDERED ENDS. HOT WATER PIPING WILL BE INSULATED AND

TYPE. WATER PIPING SHALL BE COPPER. FITTINGS SHALL BE CAST BRONZE OR COPPER

13. PLUMBING FIXTURES SHALL BE OF COMMERCIAL GRADE AND OF WATER CONSERVING

MAKING ALL NECESSARY DUCT CONNECTIONS FUNCTION AS ORIGINALLY INTENDED.

INSTALLATION, REMOVE THE EXISTING DUCTWORK AND REPLACE WITH NEW DUCTWORK,

EXISTING DUCTWORK ELEVATION AND LOCATION IS IN CONFLICT WITH THE NEW PIPING

MUST COORDINATE WITH THE EXISTING DUCTWORK ELEVATIONS AND LOCATION. IF THE

12. PRIOR TO THE INSTALLATION OF NEW HVAC AND PLUMBING PIPING, THE CONTRACTOR

CONTRACTING OFFICER FOR APPROVAL.

CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED TO THE

FIELD CONDITIONS. SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE

11. SOME DETAILS SHOWN ON THE CONTRACT DRAWINGS MAY NOT MATCH EXACTLY TO THE

SUCH AS ANCHORS, HANGERS/SUPPORTS, ETC.

10. ALL HVAC PIPING/DUCTWORK TO BE REMOVED SHALL INCLUDE ALL ITS ACCESSORIES,

PATCHED OR RESTORED TO MATCH THE ADJACENT SURFACE OR AREA.

9. ANY OPENING RESULT FROM THE REMOVAL WORK THAT IS NOT TO BE REUSED SHALL BE

DUCTWORK SHALL MEET THE REQUIREMENTS OF SEAL CLASS C.

ACCORDING TO SMACNA STATIC PRESSURE CONSTRUCTION CLASS 500PA AND

8. ALL SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED

AREA.

DUCTWORK SHALL BE PATCHED OR RESTORED TO MATCH THE ADJACENT SURFACE OR

7. ALL WALL/FLOOR/ROOF OPENINGS RESULTING FROM THE REMOVAL OF PIPING AND

SHOP DRAWING SHALL NOT BE THE EXACT DUPLICATION OF THE CONTRACT DRAWING.

6. NO MECHANICAL WORK CAN BE STARTED WITHOUT AN APPROVED SHOP DRAWING. A

5. CONCRETE REMOVAL AND RESTORATION SHALL CONFORM TO SPEC.

4. ANY PIPES THAT PENETRATE FIRE RATED WALLS (EXISTING/NEW) SHALL BE SEALED PER SPEC.

OR REPLACED BY THE CONTRACTOR.

DAMAGES DUE TO THE WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED

DAMAGE THE EXISTING EQUIPMENT, NEW EQUIPMENT, DUCTWORK, PIPING, ETC.

3. CONNECTIONS TO EXISTING SYSTEMS SHALL BE DONE IN SUCH A MANNER AS NOT TO

APPROXIMATE AND SHALL BE VERIFIED AT THE JOB SITE.

2. LOCATION AND SIZES OF EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. ARE

CORRECTIONS FOR THE CONTRACTING OFFICER'S APPROVAL.

CONTRACTING OFFICER'S REPRESENTATIVE WITH RECOMMENDATIONS FOR PROPER

DISCREPANCY IS DETECTED, IT SHOULD BE BROUGHT TO THE ATTENTION OF THE

EXISTING CONDITIONS, EQUIPMENT, FINISHES, ETC., PRIOR TO START OF WORK. IF ANY

1. THE CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH THE

GENERAL NOTES

GENERAL NOTES & SCOPE OF WORK

SCOPE OF WORK

REPAIR AND MAINTENANCE WORK (K-WORK)

GALVANIZED STEEL PIPE WITH CAST IRON DRAINAGE FITTINGS.

ABOVEGROUND VENT PIPING WILL BE HUBLESS CAST IRON PIPE AND FITTINGS OR

LAGGED COPPER PIPING. SOIL, WASTE, AND VENT PIPING WILL BE CAST IRON SOIL PIPE.

WITH TIN-ANTIMONY SOLDERED ENDS. HOT WATER PIPING WILL BE INSULATED AND

TYPE. WATER PIPING SHALL BE COPPER. FITTINGS SHALL BE CAST BRONZE OR COPPER

13. PLUMBING FIXTURES SHALL BE OF COMMERCIAL GRADE AND OF WATER CONSERVING

THE GROUNDING CONDUCTORS SHALL BE SEPARATELY PROVIDED FOR

MECHANICAL EQUIPMENT UNLESS OTHERWISE INDICATED ON THE DRAWING.

14.

15.

ALL ELECTRICAL WORK SHALL CONFORM TO THE CURRENT REQUIREMENTS

OF THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE,

FIRE CODE AND SPECIFICATIONS.

PROPER SIZE OF WIRE AND CONDUIT IN ACCORDANCE WITH MECHANICAL EQUIPMENT

SCHEDULE FOR GOVERNMENT APPROVAL PRIOR TO CONSTRUCTION.

16.

BLDG# S-247, CP CASEY

17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED AREA

INCLUDING SODDING, UTILITIES, STRUCTURES TO THEIR ORIGINAL CONDITION AND

OPERATION DURING AND AFTER INSTALLATION OF ELECTRICAL SYSTEM.

PURPOSE ONLY. CONTRACTOR SHALL VERIFY EXISITNG SITES CONDITION AND SUBMIT

SIZE AND COUNT OF WIRE, CONDUIT & ELECTRICAL DEVICES SHOWN ON DRAWING ARE ESTIMATED FOR BIDDING

1. REPAIR BY REPLACEMENT OF EXISTING ELECTRIC UNIT HEATER WITH NEW.

2. REPAIR BY REPLACEMENT OF EXISTING WALL EXHAUST FAN AND CONTROL WITH NEW.

3. REPAIR BY REPLACEMENT OF EXISTING LOUVER AND MOTORIZED DAMPER WITH NEW.

(STORAGE S-247)

REPAIR OPERATION FACILITES IN AHA 23

M-3

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

M E C H A N I C A L E Q U I P M E N T S C H E D U L E

1 21115/1/60142

CENTRIFUGAL FAN

WALL MOUNTED, BELT DRIVEN,EF

1 3

R E M A R K SRPM

KW

(Pa)

ESP

(LPS)

AIR CAP

FAN MOTOR

VOLT/PH/HZ

W/ DISCONNECT SWITCH

BIRDSCREENW/ BACKDRAFT DAMPER

N O T ETYPES E R V I C EQ'TYITEM NO

DISCHARGE

HORIZONTAL

TYPE

120/1/601

EUH

POWER

HEATING ELEMENT CAP

VOLT/PH/HZ

REMARKSSERVICEQTYNO

ELECTRIC UNIT HEATER

T Y P E

MECH RM

ITEM FAN CAPACITY

RPM VOLT/PH/HZAIR CAP.

1,600 120/1/60

(KW) (LPS)

AND BUILT-IN THERMOSTAT.

PROVIDE UNIT MTD. DISCONNECT SWITCH.

189 6

WATTS

MOTOR

MECH ROOM

EXHAUST FANS

63 1,050 0.019 3

MECHANICAL EQUIPMENT SCHEDULE

(STORAGE S-247)

REPAIR OPERATION FACILITES IN AHA 23

M-4

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

SPECIFIC NOTES

M6

REMOVAL FLOOR PLAN(BLDG# S-247, CP CASEY)

SCALE : 1 / 100

AND SPECIFIC NOTES

(BLDG# S-247, CP CASEY)

REMOVAL FLOOR PLAN

STORAGE

OFFICE

MECH RM

EE/S

S/S

M

REMOVE EXISTING MOP SINK, ACCESSORIES AND ASSOCIATED PIPING.

REMOVE EXISTING SAFETY SHOWER & EYE WASH AND ASSOCIATED PIPING.

REMOVE EXISTING ALL EQUIPMENTS, ACCESSORIES AND ASSOCIATED PIPING IN MECH ROOM.

REMOVE EXISTING LOUVER AND MOTORIZED DAMPER .

REMAIN EXISTING HEAT PUMP SYSTEM.

(STORAGE S-247)

REPAIR OPERATION FACILITES IN AHA 23

M-5

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

M6 SCALE : 1 / 100

(BLDG# S-247, CP CASEY)

HVAC FLOOR PLAN

STORAGE

OFFICE

MECH RM

M

EF

EUH

T

MOTORIZED DAMPER WITH LOUVER

(STORAGE S-247)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYCHONG, ST

HVAC FLOOR PLAN(BLDG# S-247, CP CASEY)

186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M1
186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M2
186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M3
186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M4
186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M5
186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M6
186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M7
186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M8
186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M9
186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M10
186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M11
186685, Repair operation facilities in AHA 23, Cp Casey(FINAL)-M12