A-1

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

AND GENERAL NOTES

EXISTING/REMOVAL FLOOR PLAN

MANUFACTURES INDICATED.

PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE

COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.

ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).

CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS

FOR APPROVAL.

CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR

CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE

SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD

8.

FOR APPROVAL.

CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR

2.

3.

4.

5.

6.

7.

CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER.

IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT, THE GENERAL

AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.

THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION

OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE.

APPROPRIATE TEMPORARY SUPPORTS SHOULD BE CONSTRUCTED PRIOR TO DEMOLITION

9.

10.

11.

12.

13.

14.

DETAILS AND GET APPROVAL FROM COR. BEFORE FABRICATION AND INSTALLATION.

CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR/WINDOW

ADDITIONAL COST TO THE GOVERNMENT.

EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM WITHOUT

THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING, HEATING,

ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE REQUIRED FOR

THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVE/REINSTALL ANY OBSTRUCTED

GENERAL NOTES

SPECIFICATION 15181.

ITEMS REQUIRING MAINTENANCE/OPERATION IAW THE SECTION 3.1.14, OMA STD

PROVIDE ACCESS DOORS FOR ALL CONCEALED VALVES, VENTS, CONTROLS AND OTHER

COMMENCEMENT OF FLOOR TILE WORK AND AS PER FLOOR FINISH SCHEDULE.

ALL CONCRETE FLOOR SURFACES SHALL BE LEVELED AND SMOOTHED PRIOR TO

OFFICE, DPW. PER DIRECTION FROM THE INSPECTOR IN CHARGE OR COR.

SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE

SHALL BE AS A PART OF THE CONTRACT DOCUMENT OF THIS PROJECT.

STANDARD DETAIL DRAWINGS FOR O&MA PROJECT, KOREA, DATED OCTOBER 1, 2003

1.67 K. SM/W

3.34 K. SM/W

AS FOLLOWS :

WALL

ROOF

"R" VALUE FOR INSULATION SHALL BE

& COATING.

REMOVE & CLEAN EXISTING PAINT BY SAND PAPER/ GRINDING FOR NEW PAINTING

FROM THE MANUFACTURE SHOWING THE PRODUCT IS LEAD FREE.

A CERTIFICATE OR MATERIAL SAFETY DATA SHEET (MSDS), WRITTEN IN ENGLISH,

SOLIDS) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR WILL PROVIDE

COATINGS WITH LESS THAN 0.05 PERCENT LEAD BY WEIGHT OF THE NON-VOLATILE

THE CONTRACTOR IS REQUIRED TO USE "LEAD FREE" COATINGS (LIQUID PAINTS OR

15.

16.

17.

DOCUMENTATION TO 8 CES/CEAN.

THE CONTRACTOR SHALL PROVIDE THE NEW SURVEY REPORT AND ASBESTOS REMOVAL

ACCORDANCE WITH THE KOREA ENVIRONMENTAL GOVERNING STANDARD (KEGS).

PRIOR TO ANY WORK TO ASSURE THAT APPROPRIATE ASBESTOS CONTROL IS IN

AREA WILL NEED TO BE RESURVEYED AND ASBESTOS MATERIALS SHOULD BE REMOVED

WORK IN THE AFFECTED AREA AND NOTIFY THE CONTRACTING OFFICER. THE WORK

ASBESTOS CONTAINING MATERIAL ARE DISCOVERED, THE CONTRACTOR SHALL CEASE

IS NOT PRESENT IN THE AREAS AFFECTED BY THIS WORK: HOWEVER, IF SUSPECTED

VERIFYING THE PRODUCT IS ASBESTOS FREE. TESTS HAVE INDICATED THAT ASBESTOS

WILL PROVIDE A CERTIFICATE OR MSDS, WRITTEN IN ENGLISH, FROM THE MANUFACTURER

PERCENT BY WEIGHT) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR

THE CONTRACTOR IS REQUIRED TO USE "ASBESTOS FREE" MATERIALS (LESS THAN 0.1

SCALE:

EXISTING/REMOVAL FLOOR PLAN

OFFICE

OFFICE

OFFICE

MECHANICAL

LOUNGE

VISITOR AREA

VEST

CORRIDOR

WOMEN

MEN

ENTRY OFFICE

REMOVE EXISTING WALL

REMOVE EXISTING WINDOW &

REMOVE EXISTING DOOR & DOOR

1/50

LEGEND

WINDOW FRAME

FRAME

REMOVE EXISTING CONC SLAB

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYKWON, CH

186681

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCOPE OF WORKS (ARCHITECTURAL WORK)

REPAIR / MAINTENANCE (K) WORK

1.

2.

3.

4.

6.

7.

8.

9.

5.

SIGNAGE SCHEDULE.

REPLACE INTERIOR & EXTERIOR SIGNAGES WITH NEW FOR ALL ROOMS AS SHOWN ON

11.

12.

13.

14.

15.

16.

17.

18.

HARDWARE SETS AS SHOWN ON NEW FLOOR PLAN AND DOOR SCHEDULE.

REPLACE DETERIORATED EXISTING DOORS AND DOOR FRAMES WITH NEW INCLUDING NEW

TYPE.

REPLACE DETERIORATED EXISTING WINDOW HORIZONTAL MINI BLINDS WITH NEWS, FIREPROOF

FLOOR PLAN AND FINISH SCHEDULE.

WATER RESISTANT OR 'X' TYPE) CEILING INCL. CEILING SUSPENSION SYSTEM AS SHOWN ON

REPLACE DETERIORATED EXISTING CEILING WITH NEW GYPSUM WALL BOARD (GWB, NORMAL,

SLAB IF NEEDED.

CORRECTED FOR NEW FLOORING. PROVIDE LEVELING CONCRETE FOR EXISTING CONCRETE

CONCRETE, LOW SPOTS, HIGH SPOTS, PAINTING, AND UNEVEN SURFACE SHALL HAVE BEEN

SHALL BE SMOOTH, TRUE, LEVEL PLANE WITH ALL DEFECTS SUCH AS ROUGH OR SCALING

ON FLOOR PLAN & INTERIOR FINISH SCHEDULE. THE EXISTING CONCRETE FLOORING

REPLACE DETERIORATED EXISTING FLOOR TILE WITH NEW PVCT INCLUDING VCB AS SHOWN

SCHEDULE.

PAINT ON ALL INTERIOR SURFACES INCL CEILING & WALL AS SHOWN ON INTERIOR FINISH

10.

AS SHOWN ON FLOOR PLAN AND WINDOW SCHEDULE.

+ 12 THK AIR SPACE + 6 THK TINTED LOW-E TEMPERED GLASS ( SHGC : MAX 0.4 )

THERMAL BREAKER TYPE BLAST WINDOWS INCLUDING 8.75 THK CLEAR LAMINATED GLASS

REPLACE DETERIORATED EXISTING WINDOWS INCL INSECT SCREEN WITH NEW ALUMINUM

AS SHOWN ON FLOOR PLAN AND DETAIL DRAWINGS.

REPLACE RAIN GUTTERS AND DOWNSPOUTS WITH NEW INCLUDING CONCRETE SPLASH BLOCKS

DRAWINGS.

PLASTERING W/METAL LATH AND CEMENT BOARDS AS SHOWN ON FLOOR PLAN AND DETAIL

REPLACE DETERIORATED EXISTING FCT AND GCWT(FULL HEIGHT) WITH NEW INCL.BOND COATS, DETAIL DRAWINGS.

REPLACE EXISTING ALL TOILET ACCESSORIES WITH NEW AS SHOWN ON FLOOR PLAN AND

SCALE:

SUSPENSION SYSTEMS AS SHOWN ON INTERIOR FINISH SCHEDULE.

REPLACE DETERIORATED EXISTING CEILING WITH NEW ACOUSTICAL CEILING TILE INCL. METAL

ON NEW FLOOR PLAN AND DETAIL DRAWING.

REPLACE DETERIORATED EXISTING FIRE EXTINGUISHER CABINET(FEC) WITH NEW AS SHOWN

0A

0A0A 0A

A-2

FEC

W1W2W2W1

W1

W1 W1 W1 W1

W1

W1

W3

W3

D2 D3 D4

D7

D1 D6

D9D8

D10 D11

D12

D13

D5

OFFICE

OFFICE

1/50

VEST

OFFICE

SENTRY

AREA

VISITOR

ROOM

LOUNGE

TOILET

MEN

TOILET

WOMEN

OFFICE

CORRIDOR

LEGEND

200 MM METAL STUD WALL

EXISTING CMU WALL W/50MM STUD WALL

13,836

,3

150 MM METAL STUD WALL

EXST ROOF LINE

ROOM

MECH

A-2

BB BB

A-5

A-6

ON FLOOR PLAN AND SECTIONS.

APPLY ACRYLIC FLUID-APPLIED WATERPROOFING COATING ON EXISTING ROOF AS SHOWN

(SEE MECH DRAWING)

REPLACE EXISTING CONCRETE SLAB AS NEED TO REPLACE MECHANICAL PIPING WORK.

SHOWN ON FLOOR PLAN AND EXTERIOR ELEVATION.

SOFFIT, HAND RAILS AND OTHER COMPONENTS OF EXTERIOR SURFACE OF THE BUILDING AS

PAINT ALL EXISTING EXTERIOR EXPOSED EIFS, METAL, WOODS, CONCRETE SURFACES, FASCIA, 19.

20.

AND INTERIOR FINISH SCHEDULE.

REPLACE DETERIORATED EXISTING BULLETIN BOARDS AS SHOWN ON FLOOR PLAN, ELEVATIONS

AS SHOWN ON FLOOR PLAN AND ELEVATION.

REPLACE DETERIORATED EXISTING KITCHENETTE INCLUDING BASE CABINET AND UPPER CABINET

INSULATION AS SHOWN ON FLOOR PLAN, SECTIONS AND DETAIL DRAWINGS.

REPLACE DETERIORATED EXISTING ALL GWB WALLS WITH NEW INCLUDING METAL STUDS AND

PLAN AND ELEVATIONS.

REPLACE DETERIORATED EXISTING WINDOW SECURITY BARS WITH PAINTING AS SHOWN ON FLOOR

FLOOR PLAN AND DETAIL DRAWING. (NATURAL COLOR, OAK)

REPLACE DETERIORATED EXISTING WOODEN SILL FOR ALL WINDOWS WITH NEW AS SHOWN ON

GROUND FLOOR PLAN

AND SCOPE OF WORK

GROUND FLOOR PLAN

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYKWON, CH

186681

A-2

A-2

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE:

FRONT ELEVATION

1 : 50 SCALE:

2 1 : 50

RIGHT SIDE ELEVATION

SCALE:

3 1 : 50

REAR ELEVATION SCALE:

4 1 : 50

LERT SIDE ELEVATION

CONC SLAB (TYP)

WATERPROOFING ON EXISTING

APPLY ACRYLIC FLUID-APPLIED

CONC SLAB (TYP)

WATERPROOFING ON EXISTING

APPLY ACRYLIC FLUID-APPLIED

HAND RAIL (TYP)

PAINT ON EXST

PAINT ON EXST EIFS (TYP)

PAINT ON EXST EIFS (TYP)

PAINT ON EXST EIFS (TYP)

& DOWN SPOUT (TYP)

RAIN GUTTER

(TYP)

CONC SPLASH BLOCK

(TYP)

CONC SPLASH BLOCK

& DOWN SPOUT (TYP)

RAIN GUTTER

HAND RAIL (TYP)

PAINT ON EXST

(TYP)

INSULATION BLAST DOOR

EXST CONC STEP (TYP)

A-3

ELEVATIONS

(TYP)

WINDOW SECURITY BAR

FLASHING (TYP)

W/PROTECTED METAL

AL BLAST WINDOW

(TYP)

WINDOW SECURITY BAR

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYKWON, CH

186681

W/METAL FLASHING (TYP)

AL BLAST WINDOW

W/METAL FLASHING (TYP)

AL BLAST WINDOW

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

VCB

108 107

OFFICE

FINISH PER

SCHEDULE

VCB

FINISH PER

SCHEDULE

FT ON CEMENT

MORTAR BED

CONC SLAB

ON 200 MET STUD

ON 12T CEMENT BOARD

1A 1/10

INTERIOR WALL SECTION

1B

1/10

INTERIOR WALL SECTION

FINISH PER

SCHEDULE

FINISH PER

SCHEDULE

@ 400 OC (MAX)

M.TOILET W.TOILET

OFFICE

SCALE :SCALE :

GCWT ON BOND COAT

@ 400 OC (TYP)

ON 150 MET STUD

GWB WALL W/PAINT

50 THK

W/ACOUSTICAL INSUL

12T CEMENT BOARD

OFFICE

CORRIDOR

LOUNGE SENTRY OFC

SENTRY OFC VEST

111 102

104 103

101 110

VCB

VCB

FINISH PER

SCHEDULE

1C 1/10

INTERIOR WALL SECTION

FINISH PER

SCHEDULE

OFFICE

SCALE :

@ 400 OC (TYP)

ON 150 MET STUD

GWB WALL W/PAINT

90 THK (TYP)

ACOUSTICAL INSULATION

CORRIDOR

LOUNGE SENTRY OFC

SENTRY OFC VEST

111 102

104 103

1D 1/10

INTERIOR WALL SECTION

SCALE :

MECH RMCORRIDOR

111 109

VCB

FINISH PER

SCHEDULE

CMU WALL (TYP)

PAINT ON EXST

EXST CMU WALL

PAINT ON EXST MTL LINER

1A

A-4

1B

A-4

KEY PLAN

OFFICE

OFFICE

VEST

OFFICE

SENTRY

ROOM

LOUNGE

TOILET

MEN

TOILET

WOMEN

OFFICE

CORRIDOR

1C

A-4

ROOM

MECH

1D

A-4

ARCHITECTURAL

INTERIOR WALL SECTIONS

A-4

(GCWT)

M. TOILET

(GCWT)

LOUNGE

ON WATERPROOFING MEMBRANE

ON METAL LATH W/PLASTERING

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

FEC

TOILET

MEN

108 TOILET

WOMEN

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

SCALE: 1 : 20

A

B

C

D

A

B

C

D

ENLARGED TOILET FLOOR PLAN

B

DC

A

INTERIOR ELEVATIONS ( W TOILET 108 )

SCALE: 1/20

MG

SD

SMLD

LAV

BA

DC

INTERIOR ELEVATIONS ( M TOILET 107 )

SCALE: 1/20

US

UR

SMLD

TP

UR

SD

PTD

A-5 A-5

ARCHITECTURAL

A-5

AND INTERIOR ELEVATIONS

ENLARGED TOILET FLOOR PLAN

M/W

(GFGI)

A A-5

A

SCALE: 1/20

ROOM

LOUNGE

INTERIOR ELEVATIONS ( LOUNGE 106 )

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYKWON, CH

186681

WC

TTD

SND

SND

TTD

WC

MG

SD

SMLD

LAV

PTD

(TYP)

GCWT

TTD

WC

SMLD

TP

SDPTD

TTD

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

AREA

VISITOR

OFFICE

SENTRY

SCALE: 1 : 25

ENLARGED SENTRY/VISITOR FLOOR PLAN

SCALE: 1 : 25

INTERIOR ELEVATION (SENTRY RM)

SCALE: 1 : 25

INTERIOR ELEVATION (VISITOR AREA)

PAINT TO MATCH WALL FINISH

M A

IN

T A

IN

m m

C L E

R

BLOCKING AS

REQUIRED

CONTINUOUS SEALANT

AT PARTITIONS

ARCHITECTURAL

A-6

ELEVATIONS AND DETAILS

ENLARGED FLOOR PLAN, INTERIOR

SCALE: 1 : 10

CABINET DETAIL

18 THK PLYWOOD

(COUNTERTOP, BACK &

13 THK SOLID SURFACE

MATERIAL (SSM-1) OVER

SIDE SPLASH)

ON 18 THK PLYWOOD

PLASTIC LAMINATE (PL-1)

W/ HINGE (2PR-BO1602

@ EACH DOOR)

(FRONT, BACK & EDGE)

ON 7.5 THK PLYWOOD(FRONT)

PLASTIC LAMINATE (PL-2)

PLASTIC LAMINATE (PL-2)

ON 18 THK PLYWOOD

(TOP & EDGE)

10 DIA POLISHED BRASS ROD

PULL @ EACH DOOR (B02011) OAK, NATURAL COLOR

WOOD TRIM

18 THK PLYWOOD

13 THK SOLID SURFACE

GLASS, 30MM THK

BULLET RESISTIVE

AL WOOD TRIM

WOOD FRAME

ADJUSTABLE AL

SCALE: 1 : 5

PASS THRU WINDOW DETAIL

18 THK PLYWOOD

13 THK SOLID SURFACE

MATERIAL (SSM-1) OVER

OAK, NATURAL COLOR

WOOD TRIM

SST STD TRAY

PLASTIC LAMINATE (PL-1)

ON 18 THK PLYWOOD

A-6

CMU WALL (TYP)

PAINT ON EXST

M

IN

MATERIAL (SSM-1) ON

18 THK PLYWOOD

13 THK SOLID SURFACE

MATERIAL (SSM-1) ON

WOOD FRAMING

K N

E

S P

A C

E

PLASTIC LAMINATE (PL-1)

ON 18 THK PLYWOOD

18 THK PLYWOOD

13 THK SOLID SURFACE

MATERIAL (SSM-1) ON

BULLETIN BOARD BULLETIN BOARD(TYP)

GLASS, 30MM THK

BULLET RESISTIVE

AREA

VISITOR

OFFICE

SENTRY

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYKWON, CH

186681

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

A-7

FIRE EXTINGUISHER CABINET DETAILS

EXTINGUISHER CABINET

METAL DOOR PULL

(OUTSIDE TRIM DIM)

O

U T S

ID

T

IM

D

METAL TRIM

GLASS

METAL FIRE

(ALL AROUND)

FLOOR FINISH

LINE

FINISH AS

SCHEDULED

WOOD SHIM

METAL DOOR

PULL

(INSIDE BOX DIM)

(OUTSIDE TRIM DIM)

METAL DOOR

PULL

(ALL AROUND)

WOOD SHIM

A

A

SCREW (3-PER

SIDE)

3A

PLAN

3B

SECTION "A-A"

3C

ELEVATION

SCALE: N/A

WOOD BASE

NOT TO SCALE

GUTTER EXPANSION JOINT DETAIL

SCALE : 1/5

DOWNSPOUT HANGER DETAIL

SCALE:

FRONT 12 LOWER

THAN BACK (MIN)

GUTTER LAP

ENDS

MET GUTTER

SLOPE

A

A

SLOPE

1/16 PER FT

SECTION A-A

1/16 PER FT

SLOPE

CLEAT TO REMAIN

CONTINUOUS

GUTTER

RIVET &

SOLDER

EXISTING PROTECTED

CLEAN & REPAINT

*NOTE

DISTANCE BETWEEN GUTTER EXPANSION JOINTS

SHOULD NOT BE EXCEEDED MAX 12,000mm.

WATER TIGHT

ENCLOSURE W/ SEAL

EXISTING

PROTECTED

EXISTING

METAL ROOFING

(TYP)

(TYP)

6 DIAx80

@ 900 OC

METAL DS

1.5 THK X 50 W

DS STRAP HANGER

@ 900 OC (MAX)

PROTECTED METAL

W/WASHER (TYP)

CAP SCREW & NUT

RUST PROOF

PROTECTED

9 DIA EXP BOLT

75 W X 150 H X 5 THK

SST PLATE

3 THK X 50 W

SST STRAP

8 GA x 50 W STRAP

STL COLUMN

WELDED TO STL COLUMN

@ 900 OC (WELDED)

(100 x 75)

1A 1B

(TYP)

PAINT ON EXST EIFS

SCALE :

1/10

SPLASH BLOCK DETAIL

DOWNSPOUT

CENTER OF

DOWNSPOUT

PROTECTED METAL

SCALE: N/A

4B

W/ 6 DIA EXP BOLTS

BB-1 , AE-602)

BULLETIN BOARD

(SEE MATERIAL SCHEDULE

(HEAD & SILL)

3 THK METAL CLIP

@ 450 OC

O

F L

O O

R

0 SECTION

BULLETIN BOARD

ELEVATION4A

FL

CMU WALL

25x50 OAK FRAME

25x50 OAK FRAME

1,060

BULLETIN BOARD DETAIL

,2

TYP WINDOW SILL DETAIL

SEALANT

(BY WINDOW MFR)

18 THK WOOD TRIM

(NATURAL OAK

W/VARNISH FINISH)

@ 400 OC (MAX)

SEALANT

CLOSURE

MINI-BLIND

INSECT SCREEN

GLASS

FLASHINGAL SHEET

SCALE: N/A

INSULATED BLAST

ON 50X50 BLOCKING WOOD

MISC DETAILS

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

A-8

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

AND MATERIAL & COLOR SCHEDULE

INTERIOR, EXTERIOR FINISH SCHEDULE

ABBREVIATION

ROOM NAMESROOM NOS

INTERIOR FINISH SCHEDULE

FLOOR BASE WALLS CEILING

REMARKS

FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT

SURFACE

ROOFING

FLASHING

FASCIA

SOFFIT

DOOR & FRAME

MATERIAL

ROOF LINER

STEEL

COLOR

CHOCOLATE

COLOR NO.

20095

CHOCOLATE

CHOCOLATE

CHOCOLATE

CHOCOLATE

20095

20095

20095

20095

REMARKS

WALL EIFS

WALL CMU

BEAM/COL CONC

STAIR CONC

SAND-STONE

SAND-STONE

SAND-STONE

SAND-STONE

23617

23617

23617

23617

PROTECTED METAL

PROTECTED METAL

PROTECTED METAL

EXTERIOR COLOR SCHEDULE-1

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FIRE EXTINGUISHER CABINETFEC

GYPSUM WALL BOARD

SOUND ABSORPTION WALL PANEL

QT QUARRY TILE

VINYL COVE BASE

SPRAY TEXTURE

VCB

ST

SAWP

FACTORY FINISH

HARDENER

PROTECTED METALPM

GWB

HDR

FF

CERAMIC MOSAIC TILE

EXTERIOR INSULATION & FINISH SYSTEM

SKIM COAT OF PLASTER

CMT

EIFS

ACOUSTICAL TILEACST

CMU CONCRETE MASONRY UNIT

CPL CEMENT PLASTER

PVCT

MATERIAL & COLOR SCHEDULE

FLOOR MATERIAL/COLOR BASE MATERIAL/COLOR

WALL MATERIAL/COLOR

CEILING MATERIAL/COLOR

PVCT-1

OR APPROVED EQUAL

457.2MMx457.2MM, 3MM THK

KCC SENSE TILE, CERAMIC, TN2412C

PVC TILE

PVC TILE

MAT'L

EXST

MAT'L

NEW

MAT'L

EXST

MAT'L

NEW

MAT'L

EXST

MAT'L

NEW

MAT'L

NEW

MAT'L

EXST

VCBPVCT VCB

VCBPVCT VCB

PVCT

F.F.

F.F.

F.F.

F.F.

PVCT-1

PVCT-1

F.F.

F.F.

VCB-1

VCB-1

ACST

GWB PAINT PT-2

VCT

VCT

VCT

VCT

PVCT-1 VCB VCB

ACST

GWB

TC TEXTURE COATING

AWP ACOUSTIC WALL PANEL

FINISH SCHEDULE NOTES :

MANUFACTURERS STANDARD MUST APPROACH.

COLOR IS NOT REQUIRED. THE SELECTIONS SERVE ONLY TO INDICATE THE COLOR WHICH THE

INTENDED TO LIMIT SELECTIONS OF PRODUCTS. AN EXACT MATCH OF THE MANUFACTURERS

MANUFACTURERS' COLORS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY AND ARE NOT

USER AGENCY.

SELECTION OF INTERIOR PAINT AND FACTORY APPLIED COLORS SHALL BE APPROVED BY

SHALL BE WATERPROOF TYPE GWB.GWB FOR TOILETS, AND OTHER WET AREAS

F.F. VCB-1

VCBPVCT VCBF.F. PVCT-1 F.F. VCB-1 2400VCT

SENTRY OFFICE

PAINT PT-1

ACSTACSTPAINT PT-1

2400GWB PAINTGWB GWBGWB PAINT PT-1 PT-2

GWB PAINTGWBPAINT PT-1 PT-2

VCT 2400F.F. GWB PAINT PT-2

GWB* : WATER RESISTANT TYPE

GWB

1.

2.

3.

FT-1

OR APPROVED EQUAL

NON-SLIP, 300 x 300 x 8 THK

FG 7L67-1, MARON

DONGSEO, INUS

NON-SLIP CERAMIC FLOOR TILE

VCB-1

OR APPROVED EQUAL

DARK BROWN, 100 HGT, 3THK

LG HAUSYS

VINYL COVE BASE

GCWT-1

* GROUT COLOR FOR GCWT

OR APPROVED EQUAL

: MOLD & MILDEW RESISTANT, STAIN PROOF

ANTIQUE WHITE

OR APPROVED EQUAL

300 x 600 x 10 THK

LQR 1N92-1, GLOSS

DONGSEO, INUS

GLAZED CERAMIC WALL TILE

PT-1

OR APPROVED EQUAL

LATEX/SEMIGLOSS

NOROO NR7066

PAINT COLOR

ACST-1

PT-2

OR APPROVED EQUAL

LATEX/EGGSHELL

NOROO NR7066

PAINT COLOR

OR APPROVED EQUAL

WHITE

MC 3102

"KCC MITONE"

603MM x 603MM x 15MM THK

ACOUSTICAL CEILING TILE

* GROUT COLOR FOR GCWT

OR APPROVED EQUAL

: MOLD & MILDEW RESISTANT, STAIN PROOF

ANTIQUE WHITE

SCP

CMT 2400F.F. - GWB* PAINT PT-2- - - GCWT F.F. GWBFT FT-1 GCWT-1

CLEAN MTL VARCONC - - - - - CONC - -

111 VCBPVCT VCBF.F. PVCT-1 F.F VCB-1 ACST ACST 2400VCT F.F ACST-1PAINT PT-1

CMU/GWB -/GWB

GWB* : WATER RESISTANT TYPEGCWT

101 OFFICE

OFFICE

VEST

VISITOR AREA

LOUNGE ROOM

107 MEN TOILET

108 WOMEN TOILET

109 MECH ROOM

OFFICE

CORRIDOR

CMU/GWB -/GWB F.F. ACST-1

CMU/GWB -/GWB F.F. ACST-1

PVCT PVCT-1 VCB VCB F.F. VCB-1 CMU/GWB -/GWB PAINT PT-1

PVCT PVCT-1 VCB VCB F.F. VCB-1 CMU/GWB F.F./PAINT

/PT-1

GCWT-1

CMT 2400F.F. - GWB* PAINT PT-2- - - GCWT F.F. GWBFT FT-1 GCWT-1GCWT

VCBPVCT VCBF.F. PVCT-1 F.F. VCB-1 ACST 2400VCT ACSTPAINT PT-1CMU/GWB -/GWB F.F. ACST-1

CMU/GWB -/GWB

BB-1

APPROVED EQUAL

SIZE - 1060(W) x 760(H) OR

W/ 50 WIDE NATURAL OAK TRIM

TAN NUCORK TACKBOARD

THE MOON CO,

BULLETIN BOARD

MISC MATERIAL/COLOR

/GWB

-/GCWT

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

A-9

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

AND HARDWARE SCHEDULE

DOOR, WINDOW SCHEDULE

KEY BOX : WALL MOUNTED KEY BOX E83513.

COORDINATING WITH THE USER FOR APPROVAL BY COR.

THE CONTRACTOR SHALL SUBMIT MASTER KEYING CHART,

APPROVAL

AND WINDOW SCHEDULE AND DETAIL DRAWING TO COR FOR

CONTRACTOR SHOULD SUBMIT SHOP DRAWING FOR ALL DOOR

CONNECTED TO STRUCTURE WITH ANCHOR BOLT AND WELDING.

ALL EXTERIOR DOOR FRAME AND WINDOW FRAME SHOULD BE

AND UFC 4-010-01, PAG B-9 & 10, PARA B-3.1 THRU B-3.1.4

ALL EXTERIOR DOOR, GLAZED WINDOW: SEE SEPC SECTION 08391;

4.

5.

6.

8.

9.

7.

HEAT GAIN AND FIRERATED.

WHITE OR LIGHT BEIGE TO MAXIMIZE REFLECTANCE AND MINIMIZE

BE EQUIPPED WITH HORIZONTAL MINI BLINDS. COLOR SHALL BE

WINDOWS IN ALL AREAS WHERE FUNCTIONALLY WARRANTED SHALL

1.

2.

INSECT SCREEN SHOULD BE EQUIPPED TO ALL EXTERIOR WINDOWS.

NATURAL COLOR FINISH W/ QUARTER SLICED OAK.

ALL WOOD FLUSH DOORS SHALL BE FINISHED FACTORY COATED

10.

MANUFACTURER'S LISTED INSTRUCTIONS.

INSTALLED IN ACCORDANCE WITH NFPA 80 OR THE DOOR

INSTALLATION INSTRUCTIONS. FIRE RATED DOORS SHALL BE

TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER

DOOR FRAMES & FIRE RATED GLASS. FIRE RATED DOOR FRAMES

ALL FIRE RATED DOORS SHALL BE INSTALLED IN FIRE RATED

FABRICATION AND INSTALLATION

SHALL BE APPROVED BY THE CONTRACTING OFFICER BEFORE

DOORS AND ALUMINUM WINDOWS AS ACTUAL SIZE, AND DRAWINGS

THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL

SAVING GRADE BY KOREA GOVERNMENT.

ALL WINDOWS SHOULD HAVE CERTIFICATIONS FOR ENERGY

11.

DOOR & WINDOW NOTES

HIGH QUALITY AND GRADE PRODUCTS WITH APPROVAL TO COR.

& QUALITY ARE NOT REQUIRED. BUT CONTRACTOR SHOULD INSTALL

AN EXACT MATCH OF THE MANUFACTURERS FUNCTION, GRADE, COLOR,

AND ARE NOT INTENDED TO LIMIT SELECTIONS OF PRODUCTS.

MANUFACTURERS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY

REMARKS

DOOR DIMENSION

WIDTH

MATERIAL

DOOR

TYPE

DOOR

NOS.

ROUGH OPENING

WIDTH HEIGHT

HDW

SET

THICKHEIGHT NO (HR)

RATED

FIRE

LOUVERGLAZING

CUT

UNDER

FRAME

D8

D1

DOOR

DOOR / WINDOW / LOUVER SCHEDULE

HARDWARE SCHEDULE

E GLASS AL 1016 1720 142- -

7 - --

500x300

1EA-

-C STEEL 2133800 2200 714 34.9 8 -

- -A STEEL STEEL 21331000 2200 914 44.5 1 -

- -A 2200 2133 244.5

-B 4 -

-A 3 -

INSULATED STL DOOR

E

W/ STL FRAME

A

PANEL AS

GLASS VISION

SCHEDULE

C

WOOD SOLID DOOR

D

HDW-1

THRESHOLD J32100

CLOSER C020211

HDW-7

HDW-3

CLOSER C020211

THRESHOLD J32100

HDW-5

HDW-4

DOOR/ WINDOW ELEVATIONS

(ANODIZED DARK BRONZE)

AL BLAST WINDOW

(THERMAL BREAK TYPE)

SLIDING

W/ INSECT SCREEN

- PEAK REFLECTED PRESSURE

: 40.6 KPA

- PEAK IMPULSE

: 210 KPA-MS

( SHGC : MAX 0.4 )

+ 6 THK TINTED LOW-E TEMPERED GLASS

+ 12 THK AIR SPACE

: 8.75 THK CLEAR LAMINATED GLASS

TYPICAL INSULATED/LAMINATED GLASS FOR WINDOWS12.

* MINI-BLIND, TYPICAL INSULATED/LAMINATED GLASS

1) INSULATED GLASS, 8.75T + 5 + 4

WEATHER STRIP & SEAL

THERMAL INSULATED

METAL BLAST DOOR

W/ METAL FRAME

- PEAK REFLECTED PRESSURE

: 40.6 KPA

- PEAK IMPULSE

: 210 KPA-MS

W/ STL FRAME

NATURAL FACTORY FINISH

FIXED

F

D5 - -A 5 -

44.5C 6 - --D6

HDW-6

D2

D3

D4

C 7 - -

HINGES 8112 114X114

DOOR CLOSER CO20111

1 DOOR STOP LO2161

THRESHOLD J321001

HDW-8

D9 - -

D10

1) INSULATED GLASS, 8.75T + 5 + 4

HDW-9

B

W/METAL FRAME

METAL DOOR

THERMAL INSULATED

D7 21331000 2200 914 44.5

THRESHOLD J32100

CLOSER C020211

LOCKSET F07 LEVER TYPE

WEATHER STRIP & SEAL

E GLASS AL 1016 660 142- - * MINI-BLIND, TYPICAL INSULATED/LAMINATED GLASS

100X600

1) 1EA-

STEEL

STEEL

GLASS ( SHGC : MAX 0.4 )

+ 6 THK TINTED LOW-E TEMPERED

+ 12 THK AIR SPACE

8.75 THK CLEAR LAMINATED GLASS

W2

W1

44.5D 1016 2185 914 2133 9 --STEEL STEEL

100X600

1) 1EA-

100X600

1) 1EA-

100X600

1) 1EA-

100X600

1) 1EA-

STEEL STEEL 1000 914

STEEL STEEL 1000 2200 914 2133 44.5

STEEL STEEL 1000 2200 914 2133 44.5

STEEL STEEL 1000 2200 914 2133 44.5

WOOD 1000 2200 914 2133

1) INSULATED GLASS, 8.75T + 5 + 4

1) INSULATED GLASS, 8.75T + 5 + 4

1) INSULATED GLASS, 8.75T + 5 + 4

WOOD

C STEEL 2133800 2200 714 34.9 8 -

44.5C STEELWOOD 1000 2200 914 2133

D11

D12

D13

1) TEMPERED GLASS, 10T

7 - --44.5C STEELWOOD 1000 2200 914 2133 -

7 - --44.5C STEELWOOD 1000 2200 914 2133 -

FIXED

RESISTIVE GLASS, 30MM THK

FRAME WITH BULLET

FIXED ALUMINUM

19MM

19MM

W3 F GLASS AL 813 1168 - - -

PANEL AS

GLASS VISION

SCHEDULE

100X600

1) 1EA-

HINGES A8111 114x114, NRP

LOCK SET F-08, LEVER TYPE

P L A N

DOOR

STEEL TUBE

WELDED TO

STEEL PLATE

DOOR

STEEL TUBE

PLATE WELDED TO

ELEVATION

SCALE:

DOOR STOP & HOLDER DETAILS

REPLACE HOOK & EYEBOLT

REPALCE WALL TYPE BUMPER L02101

BACKGROUND

PAINT BLACK

50 x 50 x 6THK

REPLACE

BUMPER L02101

REPLACE WALL TYPE

50 x 50 x 6 THK STEEL

REPLACE

HOOK & EYEBOLT

REPLACE

N/A

POLE

STRIPS ON EXISTING

PAINT YELLOW

HINGES A8112 114x114, NRP

1DOOR STOP AND HOLEDER

WEATHER STRIP & SEAL1

(WHEATERH PROOF TYPE)

SIMPLEX 5000, KABA

HINGES A8112 114x114, NRP

EXIT DEVICE TYPE-1,

(LEVER TYPE HANDLE)

FUNCTION 08

CLOSER C02021

DOOR STOP AND HOLEDER 1

1 THRESHOLD J32100

WEATHER STRIP & SEAL1

EXIT DEVICE TYPE-1,

(LEVER TYPE HANDLE)

FUNCTION 08

CLOSER C02011

1 THRESHOLD J32100

HINGES A8112 114x114

DOOR STOP L02161

3 HINGES A8112 114x114

SIMPLEX 5000, KABA

CLOSER C02011

THRESHOLD J32100

DOOR STOP L021411

MECHANICAL PUSHBUTTON LOCK

MECHANICAL PUSHBUTTON LOCK

HINGES A8112, 114x114

LOCK SET F-82, LEVER TYPE

CLOSER C02011

THRESHOLD J32100

DOOR STOP L021411

PUSH PLATE

PULL PLATE1

HINGES A8111 114x114, NRP

KICK PLATE J102, SST

KICK PLATE J102, SST

KICK PLATE J102, SST

KICK PLATE J102, SST

KICK PLATE J102, SST

KICK PLATE J102, SST

KICK PLATE J102, SST

HDW-2

CLOSER C020211

THRESHOLD J32100

HINGES A8112 114x114, NRP

1DOOR STOP AND HOLEDER

WEATHER STRIP & SEAL1

(VERIFY W/ELEC STRIKE)

KICK PLATE J102, SST

1 CONTROL PANEL W/INTERCOM SYS

ELECTRICAL STRIKE

LOCKSET 1000-1, F07, LEVER TYPE

OR APPROVED EQUAL

-4EA OF AA BATTERIES PER EACH LOCKSET

TURNED INTO USING AGENCY

-ADDITIONALLY 20% OF BLANK CARD KEYS SHOULD BE

-O&M TRANING TO DPW BY MANUFACTURER

-MASTER KEY SYSTEM

-CARD KEYED TYPE WITH 3EA CARD KEYS & PROGRAM

-SELF LOCKING

ONITY, MAGSTRIPE HT24

ELECTRONIC CARD KEYED LOCKSET,

DOOR STOP AND HOLEDER, L01371

DOOR STOP AND HOLDER, L01371

WOOD

WOOD

* BULLET RESISTIVE GLASS, 30MM THK

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

A-10

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SIGNAGE PLAN AND SCHEDULE

SIGN

TYPE

WALL DOOR

REMARKNO.

TYPE

MESSAGE

CLG

S I G N A G E S C H E D U L E

MOUNTING

A

SIGNAGE PLAN

SCALE:

BUILDING IDENTIFICATION

COORDINATED WITH THE CONTRACTING

BY THE CONTRACTOR

OFFICER AND USING AGENCY

2. SIGN MESSAGE COPY WILL BE

NOTES:

"HELVETICA MEDIUM"

1. LETTER TYPE SHALL BE

V E

R

IF

Y

H G

T 70

OFFICE IDENTIFICATION

SEE SIGNAGE

SCHEDULE

FOR LOCATION

EQ.EQ.

AS SHOWN SIGNAGE PLAN.

ROOM NUMBERS SHALL BE

NOTE

FIN FL

CENTER OF

SIGNAGE

1. BUILDING IDENTIFICATION NUMBER

; CONTRACTOR SHALL VERIFY NUMBER, COLOR, SIZE1ST FL

IDENTIFICATION

BUILDING

NUMBER

AND HGT OF LOCATION WITH DPW

2. NOS. ARE TWO PLACES PER EACH BUILDING.

3. SEE ELEVATION FOR LOCATION.

NOTE

BY DPW

LETTER COLOR

BY DPW

COLOR

BACKGROUND

3B

BUILDING IDENTIFICATION

POLISH EDGES

ALL AROUND

(12 CAP

BACKBOARD

ON WHITE

LETTER HGT)

BLACK LETTERS

INSERT PANEL

BACKGROUND

STANDARD BROWN

WHITE LETTERS

(SEE NOTE)

TYP

3A

POLISH EDGES

ALL AROUND

(12 CAP

BACKBOARD

ON WHITE

LETTER HGT)

BLACK LETTERS

INSERT PANEL

BACKGROUND

STANDARD BROWN

WHITE LETTERS

(SEE NOTE)

TYPE "1B-1" TYPE "1B-2"

INSUL & FINISH SYSTEMEXT

MASTIC COMPOUND

6 THK AL PL

50x50x1300 TREATED

WOOD NAILER W/

8 PER SIGN

AL SLEEVE

6 DIA STAINLESS

STEEL BOLT

EXISTING BLDG TO REMAIN

N/A

SCALE:

SIZE & MOUNTING LOCATION OF SIGNAGE

N/A

SCALE:

N/A

MOUNTING DETAILS

2A 2B

3A 3B

OF HEADER SECTION AND

BACK SPLAYED WITH ENAMEL

ACRYLIC W/GRAPHIC

APPLIED TO REVERSE SIDE

2 THK CLEAR MATTE

FINISH WALL

POLISH EDGES ALL AROUND

ACRYLIC SPACER

1 THK CLEAR

(COLOR-SEE SIGNAGE

10 THK MATE ACRYLIC

TYPE & DETAILS)

(COLOR-SEE SIGNAGE

TYPE & DETAILS)

FOAM TAPE

DOUBLE EMULSION

225150 225

12 12

S-246S-246

OFFICE

OFFICE

VEST

OFFICE

SENTRY

ROOM

LOUNGE

TOILET

MEN

TOILET

WOMEN

OFFICE

CORRIDOR

ROOM

MECH

A

A

4 65

OFFICE

OFFICE

SENTRY OFFICE

LOUNGE ROOM

MEN TOILET & SYMBOL

WOMEN TOILET & SYMBOL

OFFICE

MECHANICAL ROOM

9 VISITOR AREA

SYMBOL IDENTIFICATION2C

FIN FL

EQEQ

N

TYPE "2B-1" TYPE "2B-2"

102 104

MISC

IDENTIFICATION

TOP OF

SIGNAGE

WOME

WOMEN MEN

OPTIONAL 38mm

TACTILE ROOM NUMBER

W/ BRAILE HELVETICA

NEUE 55 ROMAN (WHITE)

152 mm SYMBOL

(DARK BROWN)

25mm TACTILE ROOM

NUMBER DESCRIPTION

W/ BRAILLE HELVETICA

NEUE 55 ROMAN (WHITE)

25mm TACTILE ROOM

NUMBER DESCRIPTION

W/ BRAILLE HELVETICA

NEUE 55 ROMAN (WHITE)

152 mm SYMBOL

(DARK BROWN)

OPTIONAL 38mm

TACTILE ROOM NUMBER

W/ BRAILE HELVETICA

NEUE 55 ROMAN (WHITE)

BRAILLE

(TYP)

BRAILLE

(TYP)

EQ EQ EQ EQ

@250 OC

6 DIA EXP BOLT

AREA

VISITOR

(OPERATION BLDG S-246)

REPAIR OPERATION FACILITES IN AHA 23

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

AND SCOPE OF WORK

GOUND FLOOR PLAN, PICTURES

SCALE:

W1

W1

W1

W1

D2

D5

D3

D1

D4

STORAGE

MECH RM

4 2

OFFICE

GROUND FLOOR PLAN

1/50

FEC

(STORAGE S-247)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYKWON, CH

186681

A-1

REPAIR / MAINTENANCE (K) WORK

1.

2.

3.

4.

5.

10.

11.

12.

HARDWARE SETS AS SHOWN ON NEW FLOOR PLAN AND DOOR SCHEDULE.

REPLACE DETERIORATED EXISTING DOORS AND DOOR FRAMES WITH NEW INCLUDING NEW

TYPE.

REPLACE DETERIORATED EXISTING WINDOW HORIZONTAL MINI BLINDS WITH NEWS, FIREPROOF

13.

14.

SLAB IF NEEDED.

CORRECTED FOR NEW FLOORING. PROVIDE LEVELING CONCRETE FOR EXISTING CONCRETE

CONCRETE, LOW SPOTS, HIGH SPOTS, PAINTING, AND UNEVEN SURFACE SHALL HAVE BEEN

SHALL BE SMOOTH, TRUE, LEVEL PLANE WITH ALL DEFECTS SUCH AS ROUGH OR SCALING

ON FLOOR PLAN & INTERIOR FINISH SCHEDULE. THE EXISTING CONCRETE FLOORING

REPLACE DETERIORATED EXISTING FLOOR TILE WITH NEW PVCT INCLUDING VCB AS SHOWN

SCHEDULE.

PAINT ON ALL INTERIOR SURFACES INCL CEILING & WALL AS SHOWN ON INTERIOR FINISH

AS SHOWN ON FLOOR PLAN AND DETAIL DRAWINGS.

REPLACE RAIN GUTTERS AND DOWNSPOUTS WITH NEW INCLUDING CONCRETE SPLASH BLOCKS

FINISH AS SHWON ON FLOOR PLAN, SECTIONS AND FINISH SCHEDULE.

APPLY EPOXY COATING ON EXISTING CONCRETE SLAB INCLUDING NON SLIP ABRASIVE GRAIN

PICTURE, DOOR SCHEDULE AND DETAIL DRAWING.

STEEL GUIDE RAILS, CASING HOOD AND ACCESSORIES AS SHOWN ON FLOOR PLAN,

GALVANIZED STEEL ROLL UP DOORS INCLUDING MOTORS, EMERGENCY MANUAL CHAINS,

REPLACE DETERIORATED EXISTING ROLL UP DOORS WITH NEW THERMAL INSULATED

PAINT EXISTING GUARD POSTS AS SHOWN ON FLOOR PLAN AND ELEVATIONS.

SUSPENSION SYSTEMS AS SHOWN ON INTERIOR FINISH SCHEDULE.

REPLACE DETERIORATED EXISTING CEILING WITH NEW ACOUSTICAL CEILING TILE INCL. METAL

ON NEW FLOOR PLANS AND DETAIL DRAWING.

REPLACE DETERIORATED EXISTING FIRE EXTINGUISHER CABINET(FEC) WITH NEW AS SHOWN

REPLACE EXTERIOR SIGNAGES WITH NEW FOR ALL ROOMS AS SHOWN ON DETAIL DRAWING.

ON FLOOR PLAN AND ELEVATIONS.

APPLY ACRYLIC FLUID-APPLIED WATERPROOFING COATING ON EXISTING ROOF AS SHOWN

FASCIA, SOFFIT OF THE BUILDING AS SHOWN ON FLOOR PLAN AND ELEVATIONS.

PAINT ALL EXISTING EXTERIOR EXPOSED EIFS, CMU, METAL, WOODS, CONCRETE SURFACES,

( SHGC : MAX 0.4 ) AS SHOWN ON FLOOR PLANS AND WINDOW SCHEDULE.

LAMINATED GLASS + 12 THK AIR SPACE + 6 THK TINTED LOW-E TEMPERED GLASS

NEW ALUMINUM THERMAL BREAKER TYPE BLAST WINDOWS INCLUDING 8.75 THK CLEAR

REPLACE DETERIORATED EXISTING WINDOWS INCL INSECT SCREEN AND SECURITY BAR WITH

SCOPE OF WORK (ARCHITECTURAL WORK)

6.

7.

8.

9.

15.

16.

SCALE: N/A

FLOOR PLAN, PICTURE AND ELEVATIONS.

REPLACE DETERIORATED EXISTING WINDOW SECURITY BARS WITH PAINTING AS SHOWN ON

BUILDING PICTURES

12,211

,1

3,6488,563

,1

,9

BAR (TYP)

WINDOW SECURITY

BLAST WINDOW &

CEILING

PAINT WALL &

BAR (TYP)

WINDOW SECURITY

(TYP)

BLAST METAL DOOR

THERMAL INSULATED

PROTECTED METAL ROOF (TYP)

WATERPROOFING ON EXISTING

APPLY ACRYLIC FLUID-APPLIED

UP DOOR

OVERHEAD ROLL

BLAST WINDOW &

SPOUT (TYP)

GUTTER & DOWN

PROTECTED METAL

A-2

GUARD POST

PAINT ON EXST

A-2

A-2

A-2

AL LOUVER

L1

ELEVATION.

REPLACE DETERIORATED EXISTING LOUVER AS SHWON ON FLOOR PLAN, PICTURES AND

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE:

W2

GRADE

W2

W2 W2

PROTECTED METAL ROOF (TYP)

WATERPROOFING ON EXISTING

APPLY ACRYLIC FLUID-APPLIED

(TYP)

GUTTER

METAL

PROTECTED

(TYP)

DOWNSPOUT

METAL

PROTECTED

(TYP)

BLAST METAL DOOR

THERMAL INSULATED

ELEVATION-1

1/50

SCALE:

ELEVATION-2

1/50

SCALE:

ELEVATION-3

1/50

SCALE:

ELEVATION-4

1/50

METAL DOOR (TYP)

THERMAL INSULATED

A-2

PAINT ON EXST EIFS (TYP)

PAINT ON EXST EIFS (TYP)

PROTECTED METAL ROOF (TYP)

WATERPROOFING ON EXISTING

APPLY ACRYLIC FLUID-APPLIED

ELEVATIONS

S-1804S-1804

GRADEGRADE

(TYP)

W/FLASHING & WINDOW SECURITY BAR

INSULATED BLAST WINDOW

(TYP)

W/FLASHING & WINDOW SECURITY BAR

INSULATED BLAST WINDOW

ROLL UP DOOR

INSULATED OVERHEAD

(STORAGE S-247)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYKWON, CH

186681

METAL DOOR (TYP)

THERMAL INSULATED

GUARD POST

AL LOUVER

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

INTERIOR FINISH SCHEDULE

FLOOR BASE WALLS CEILING

REMARKS

FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT

PAINT VAR

MATERIAL & COLOR SCHEDULE

MAT'L

EXST

MAT'L

NEW

MAT'L

EXST

MAT'L

NEW

MAT'L

EXST

MAT'L

NEW

MAT'L

NEW

MAT'L

EXST

1.

2.

MANUFACTURERS STANDARD MUST APPROACH.

TO INDICATE THE COLOR WHICH THE

IS NOT REQUIRED. THE SELECTIONS SERVE ONLY

AN EXACT MATCH OF THE MANUFACTURERS COLOR

INTENDED TO LIMIT SELECTIONS OF PRODUCTS.

IDENTIFICATION PURPOSES ONLY AND ARE NOT

MANUFACTURERS' COLORS LISTED ARE FOR

3.

FLOOR MATERIAL/COLOR WALL MATERIAL/COLOR CEILING MATERIAL/COLOR

PT-2

FINISH SCHEDULE NOTES

ROOM NAMESROOM NOS

CONC CMU101 EP-1 PML-

COLORS SHALL BE APPROVED BY USING AGENCY.

SELECTION OF INTERIOR PAINT AND FACTORY APPLIED

APPROVED BY THE COR OR USING AGENCY.

THE RLFC AREA. EXTERIOR COLOR SCHEME AS

APPLIED COLORS SHALL BE IN ACCORDANCE WITH

SELECTION OF EXTERIOR PAINT AND FACTORY EP-1

EPOXY COATING - PAINT PT-3-

BASE MATERIAL/COLOR

OR APPROVED EQUAL

SEMI-GLOSS

NOROO NR9058

PAINT ENAMEL

PAINT 2440PT-2VCT CMU102 ACST-

PAINT VARPT-2CONC CMU103 PML- - PAINT PT-3-

STORAGE

MECH ROOM

PVCT F.F. PVCT-1

VCB VCB F.F. VCB-1

ACST F.F. ACST-1OFFICE

PAINT PT-1CMU

CMU

PVCT-1

OR APPROVED EQUAL

457.2MMx457.2MM, 3MM THK

KCC SENSE TILE, CERAMIC, TN2412C

PVC TILE

VCB-1

OR APPROVED EQUAL

DARK BROWN, 100 HGT, 3THK

LG HAUSYS

VINYL COVE BASE

PT-1

ACST-1

OR APPROVED EQUAL

WHITE

MC 3102

"KCC MITONE"

603MM x 603MM x 15MM THK

ACOUSTICAL CEILING TILE

OR APPROVED EQUAL

EGGSHELL

NOOROO #NR7066 SEMI-GLOSS,

PAINT ENAMEL PT-3

OR APPROVED EQUAL

NOOROO #NR7066 SEMI-GLOSS

PAINT LATEXPT-2

V E

R

IF

Y

H G

T 70

1. BUILDING IDENTIFICATION NUMBER

; CONTRACTOR SHALL VERIFY NUMBER, COLOR, SIZE1ST FL

IDENTIFICATION

BUILDING

NUMBER

AND HGT OF LOCATION WITH DPW

2. NOS. ARE TWO PLACES PER EACH BUILDING.

3. SEE ELEVATION FOR LOCATION.

NOTE

BY DPW

LETTER COLOR

BY DPW

COLOR

BACKGROUND

S-247

SCALE:

N/A

SIZE & MOUNTING LOCATION OF SIGNAGE

BUILDING IDENTIFICATION

S-247

A-3

& COLOR SCHEDULE, AND DETAILS

INTERIOR FINISH SCHEDULE, MATERIAL

THE GUTTER & TO MEET AT/FP REQUIREMENTS.

3. TO PREVENT LEAVES FROM COLLECTING IN

2. INSTALL REMOVABLE METAL SCREEN

AT ALL GUTTERS.

SHOULD NOT BE EXCEEDED MAX 12,000mm.

1. DISTANCE BETWEEN GUTTER EXPANSION JOINTS

*NOTE

SOLDER

RIVET &

GUTTER

SLOPE

1/16 PER FT

SECTION A-A

1/16 PER FT

SLOPE

SCALE: N/A

FRONT 12 LOWER

THAN BACK (MIN)

GUTTER LAP

ENDS

MET GUTTER

SLOPE

A

A

WATER TIGHT

ENCLOSURE W/ SEAL

PROTECTED

15019

GUTTER EXPANSION DETAILS

EXISTING METAL ROOFING

WATERPROOFING ON

EPOXY COATING SYSTEM

SIKA-KOREA, EPOXY, CONFORMED LEED LOW VOC,

PRIMING - SIKA FLOOR 161

1ST COAT - SIKA FLOOR 263SL (2mm)

2ND COAT : SIKA FLOOR 263SL (3mm)

W/ NON-SLIP

LIGHT GREY (APPROVED BY USER)

OR APPROVED EQUAL

(STORAGE S-247)

REPAIR OPERATION FACILITES IN AHA 23

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

REMARKS

DOOR DIMENSION

WIDTH

MATERIAL

D1

DOOR

TYPE

DOOR

NOS.

ROUGH OPENING

WIDTH HEIGHT

HDW

SET

THICKHEIGHT NO (HR)

RATED

FIRE

LOUVERGLAZING

CUT

UNDER

FRAME

D2

DOOR

DOOR / WINDOW / LOUVER SCHEDULE

A -21501000 2200 900 44.5 1 - -

B - -2 - -1000 2200

METAL METAL

METALMETAL

12701220ALE - -------AL

900 2150 44.5

HDW-1

1 THRESHOLD J32100

CLOSER CO2021

KICK PLATE J102, SST1

LOCKSET 1000-1 F071

3 HINGES 8112 114X114, NRP

DOOR STOP & HOLDER

3.

APPROVAL

AND WINDOW SCHEDULE AND DETAIL DRAWING TO COR FOR

CONTRACTOR SHOULD SUBMIT SHOP DRAWING FOR ALL DOOR

CONNECTED TO STRUCTURE WITH ANCHOR BOLT AND WELDING.

ALL EXTERIOR DOOR FRAME AND WINDOW FRAME SHOULD BE

AND UFC 4-010-01, PAG B-9 & 10, PARA B-3.1 THRU B-3.1.4

ALL EXTERIOR DOOR, GLAZED WINDOW: SEE SEPC SECTION 08391;

5.

6.

4.

HEAT GAIN AND FIRERATED.

WHITE OR LIGHT BEIGE TO MAXIMIZE REFLECTANCE AND MINIMIZE

BE EQUIPPED WITH HORIZONTAL MINI BLINDS. COLOR SHALL BE

WINDOWS IN ALL AREAS WHERE FUNCTIONALLY WARRANTED SHALL

1.

2.

FABRICATION AND INSTALLATION

SHALL BE APPROVED BY THE CONTRACTING OFFICER BEFORE

DOORS AND ALUMINUM WINDOWS AS ACTUAL SIZE, AND DRAWINGS

THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL

DOOR & WINDOW NOTES

WINDOW BLIND SHOULD BE EQUIPPED TO ALL EXTERIOR WINDOWS.

( SHGC : MAX 0.4 )

+ 6 THK TINTED LOW-E TEMPERED GLASS

+ 12 THK AIR SPACE

: 8.75 THK CLEAR LAMINATED GLASS

TYPICAL INSULATED/LAMINATED GLASS FOR WINDOWS

COR.

INSTALL HIGH QUALITY AND GRADE PRODUCTS WITH APPROVAL TO

COLOR, & QUALITY ARE NOT REQUIRED. BUT CONTRACTOR SHOULD

AN EXACT MATCH OF THE MANUFACTURERS FUNCTION, GRADE,

AND ARE NOT INTENDED TO LIMIT SELECTIONS OF PRODUCTS.

MANUFACTURERS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY

P L A N

DOOR

S E C T I O N

STEEL TUBE

WELDED TO

STEEL PLATE

DOOR

STEEL TUBE

PLATE WELDED TO

ELEVATION

SCALE:

DOOR STOP & HOLDER DETAILS

REPLACE HOOK & EYEBOLT

REPALCE WALL TYPE BUMPER L02101

BACKGROUND

PAINT BLACK

50 x 50 x 6THK

REPLACE

BUMPER L02101

REPLACE WALL TYPE

50 x 50 x 6 THK STEEL

REPLACE

HOOK & EYEBOLT

REPLACE

ROY 415 FOR SILL)

(ROY 165 FOR HEAD/JAMB

WEATHER STRIP

N/A

* MINI-BLIND

POLE

STRIPS ON EXISTING

PAINT YELLOW

DOOR / WINDOW ELEVATIONS

HARDWARE SCHEDULE

W1

D3 A - -1 - -1000 2200METALMETAL 900 2150 44.5

D4 C 2440 2440METALMETAL

D5 D - -4 - -1000 2200METALMETAL 900 2150 44.5

DOOR HOOD

C

OVERHEAD COILING

THERMAL INSULATED

METAL OVERHEAD COILINGMET DOOR

THERMAL INSULATEDA

METAL HOLLOW

CORE DOOR

W/ METAL FRAME

W/ METAL FRAME

B

D

DOOR W/ METAL FRAME

METAL BLAST RESISTANT

THERMAL INSULATED

: 40.6 KPA

- PEAK IMPULSE

: 210 KPA-MS

PRESSURE

- PEAK REFLECTED

(ANODIZED DARK BRONZE)

AL BLAST WINDOW

(THERMAL BREAK TYPE)

SLIDING

W/ INSECT SCREEN

- PEAK REFLECTED PRESSURE

: 40.6 KPA

- PEAK IMPULSE

: 210 KPA-MS

E

DOOR & TRACK (POWER

OPERATION & EMERGENCY

MANUAL CHAIN)

AS NOTES

INSULATED GLASS

FL

1) 1) 1) 1) BY DOOR MFR3

& ACCESSARIES.

DOOR MFR INCLUDING LOCKING DEVICE

ALL HARDWARE SHALL BE PROVIDED BY

HDW-2

1 THRESHOLD J32100

CLOSER CO2021

KICK PLATE J102, SST1

LOCKSET 1000-1 F081

3 HINGES 8112 114X114, NRP

DOOR STOP & HOLDER

ROY 415 FOR SILL)

(ROY 165 FOR HEAD/JAMB

WEATHER STRIP

HDW-4

1 THRESHOLD J32100

CLOSER CO2011

KICK PLATE J102, SST1

LOCKSET 4000-1 F821

HDW-3

ROLL UP DOOR NOTES

CHAIN WITH WEATHERSTRIPPING.

OPERATION, EMERGENCY HAND

STEEL ROLL UP DOOR WITH MOTOR

THERMAL INSULATED GALVANIZED

(SAFETY/WEATHER)

ELECTRIC SENSING EDGE

"OPEN-CLOSE-STOP"

THREE-BUTTON CONTROL STATION

1.

2.

3.

A-4

ROLL UP DOOR NOTES

SCHEDULE, DOOR/WINDOW NOTES AND

DOOR, WINDOW SCHEDULE, HARDWARE

DOOR STOP, L02141

HINGES 8112 114X114

(STORAGE S-247)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYKWON, CH

186681

F ALL1 - - -- --AL 400 800- -

F

AND FRAME W/ INSECT SCREEN

FIXED AL LOUVER (45°BLADES)

SCALE:

A-1

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

1/50

REPAIR / MAINTENANCE (K) WORK

1.

2.

3.

4.

6.

7.

8.

9.

5.

SCOPE OF WORK (ARCHITECTURAL WORK)

PAINT ON ALL EXTERIOR SURFACE AS SHOWN ON FLOOR PLAN & ELEVATIONS.

AS SHOWN ON FLOOR PLAN AND DOOR SCHEDULE.

REPLACE DETERIORATED EXISTING DOORS AND DOOR FRAMES WITH NEW INCLUDING HARDWARE SETS

GROUND FLOOR PLAN

SCALE: 1/50

,0

DOWNSPOUT (TYP)

RAIN GUTTER AND

,0

12,000

D1 D1

L1

L1

CROSS SECTION

STRUCTURE (TYP)

PAINT ON EXST STL

SCALE: N/A

PICTURES

FEC

STORAGE

(TYP)

PAINT ON EXST CMU WALL

AND INTERIOR FINISH SCHEDULE.

APPLY EPOXY PAINT WITH NON SLIP GRITS ON EXISTING CONC PAD AS SHOWN ON FLOOR PLAN, SECTIONS

AND DOOR/WINDOW SCHEDULE.

REPLACE DETERIORATED EXISTING ALUMINUM LOUVER WITH NEW AS SHOWN ON FLOOR PLAN, SECTION

CONC RAMP

GUARD POST (TYP)

PAINT ON EXST

10.

11.

INTERIOR FINISH SCHEDULE & SECTION.

PAINT ON ALL INTERIOR SURFACES INCLUDING CEILING, WALL & GUARD POST AS SHOWN ON FLOOR PLAN, SECTION AND PICTURES.

REPLACE DETERIORATED EXISTING GUARD POST (EXTERIOR ONLY) WITH NEW AS SHOWN ON FLOOR PLAN, CONC RAMP

(EXTERIOR ONLY)

STL GUARD POST

(EXTERIOR ONLY)

STL GUARD POST

REPLACE EXTERIOR SIGNAGES WITH NEW AS SHOWN ON FLOOR PLAN, ELEVATIONS AND SIGNAGE SCHEDULE.

ON EXIST METAL ROOF (TYP)

ACRYLIC FLUID-APPLIED WATERPROOFING

DOWNSPOUT (TYP)

RAIN GUTTER AND

PICTURES & SCOPE OF WORK

GROUND FLOOR PLAN, CROSS SECTION,

ON EXIST METAL ROOF (TYP)

ACRYLIC FLUID-APPLIED WATERPROOFING

(STORAGE S-237 & 238)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYKWON, CH

186681

CMU WALL (TYP)

PAINT ON EXIST

(TYP)

CONC GUARD POST

CONC RAMP

(TYP)

INSULATED MTL DOOR

(TYP)

AL LOUVER

FASCIA & EAVES (TYP)

PAINT ON EXST METAL

AND DETAILS.

REPLACE DETERIORATED EXISTING FIRE EXTINGUISHER CABINETS WITH NEW AS SHOWN ON FLOOR PLAN

AND ELEVATIONS INCLUDING REPAIR MINOR DAMAGES OF ROOF PRIOR TO FINISH.

APPLY ACRYLIC FLUID-APPLIED WATERPROOF COATING ON EXISTING ROOF AS SHOWN ON FLOOR PLAN

BLOCKS AS SHOWN ON FLOOR PLAN, ELEVATIONS AND DETAIL DRAWINGS.

REPLACE DETERIORATED EXISTING RAIN GUTTERS AND DOWNSPOUTS WITH NEW INCLUDING CONC SPLASH

PICTURES.

REPLACE DETERIORATED EXISTING CONC RAMP WITH NEW AS SHOWN ON FLOOR PLAN, SECTION AND

GUARD POST (TYP)

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

THE GUTTER & TO MEET AT/FP REQUIREMENTS.

3. TO PREVENT LEAVES FROM COLLECTING IN

2. INSTALL REMOVABLE METAL SCREEN

AT ALL GUTTERS.

SHOULD NOT BE EXCEEDED MAX 12,000mm.

1. DISTANCE BETWEEN GUTTER EXPANSION JOINTS

*NOTE

SOLDER

RIVET &

GUTTER

SLOPE

1/16 PER FT

SECTION A-A

1/16 PER FT

SLOPE

SCALE: N/A

FRONT 12 LOWER

THAN BACK (MIN)

GUTTER LAP

ENDS

MET GUTTER

SLOPE

A

A

WATER TIGHT

ENCLOSURE W/ SEAL

PROTECTED

15019

GUTTER EXPANSION DETAILS

EXISTING METAL ROOFING

WATERPROOFING ON

(OUTSIDE TRIM DIM.)

(OUTSIDE TRIM DIM.)

(INSIDE BOX DIM.)

FIRE EXTINGUISHER CABINET PLAN

L

IN

S

B

X

O

U T S

METAL DOOR

PULL

METAL TRIM

METAL FIRE

EXTINGUISHER CABINET

METAL DOOR PULL

GLASS

(INSIDE BOX DIM.)

WOOD SHIM

(ALL AROUND)

200 CMU WALL

CONC.FILL

IN

S

B

X

CONC.FILL

PRECAST CONC.

FLOOR FINISH

VCB

LINE

PULL

METAL DOOR

WOOD SHIM

(ALL AROUND)

PRECAST CONC.

SIDE)

SCREW (3-PER

A

A

1 : 10

1B

1A

1C

PAINT

ON EXST CMU

SCALE:

FIRE EXTINGUISHER CABINET

ELEVATION SECTION "A-A"

4430544

114 89

DETAILS

BUILDING IDENTIFICATION

SCALE:

NOTE

4B

COLOR IS TO

MATCH ROOF

COLOR

LETTER COLOR

IS TO MATCH

EXT FIELD WALL

COLOR

1. BUILDING IDENTIFICATION

NUMBER

; CONTRACTOR SHALL VERIFY

NUMBER & SIZE

2. NUMBER ARE TWO PLACES

3. LOCATION FOR SEE ELEVATION.

BUILDING

IDENTIFICATION

NUMBER

PER BUILDING.

V E

R

IF

Y B

Y

FL

N/A

800 S-237

W/ HD10 TIES

PIPE CAP

150 DIA STL

YELLOW

BLACK

150 DIA STL PIPE

FILLED W/CONC

PEJ

10 THK

@ 300 OC

WELDED TO STL PIPE

4-HD13 DOWEL BAR

4-HD16 VERT

,2

EXISTING CONCRETE SLAB

SCALE: N/A

GUARD POST DETAIL

(STORAGE S-237 & 238)

REPAIR OPERATION FACILITES IN AHA 23

CAMP CASEYKWON, CH

186681

S-237

SCALE:

CONCRETE RAMP

10MM THK PEJ

150MM CWB

W/BROOM FINISH

ON GRADE & 150MM CWB

200MM THK. CONC STOOP

D13 @ 300 OC

SLOPE

NFSM (1,100 DEPTH)

150200

N/A

1,800

EXST CONC SLAB

FOUNDATION

EXST CONC

A-3

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

ROOM NAMESROOM NOS

INTERIOR FINISH SCHEDULE

FLOOR BASE WALLS CEILING

REMARKS

FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT

MATERIAL & COLOR SCHEDULE

FLOOR MATERIAL/COLOR BASE MATERIAL/COLOR WALL MATERIAL/COLOR CEILING MATERIAL/COLOR

MAT'L

EXST

MAT'L

NEW

MAT'L

EXST

MAT'L

NEW

MAT'L

EXST

MAT'L

NEW

MAT'L

NEW

MAT'L

EXST

PAINT PT-1CMU101 CONC

1.

2.

3.

FINISH SCHEDULE NOTES

COLORS SHALL BE APPROVED BY USING AGENCY.

SELECTION OF INTERIOR PAINT AND FACTORY APPLIED

APPROVED BY THE COR OR USING AGENCY.

THE RLFC AREA. EXTERIOR COLOR SCHEME AS

APPLIED COLORS SHALL BE IN ACCORDANCE WITH

SELECTION OF EXTERIOR PAINT AND FACTORY

REMARKS

DOOR DIMENSION

WIDTH

MATERIAL

D1

DOOR

TYPE

DOOR

NOS.

ROUGH OPENING

WIDTH HEIGHT

HDW

SET

THICKHEIGHT NO (HR)

RATED

FIRE

LOUVERGLAZING

CUT

UNDER

FRAMEDOOR

DOOR / WINDOW / LOUVER SCHEDULE

A

B ALL1 - - -- --

- -METAL 44.5 1 -24002540 2480 2400METAL -

DOOR / WINDOW / LOUVER ELEVATION

A B

THERMAL INSULATED

W/ METAL FRAME

DOOR

WELDED TO

STEEL PLATE

ELEVATION

SCALE:

DOOR STOP & HOLDER DETAILS

N/A

PLAN

HDW-1

HINGES A5112 114x114, NRP

1 THRESHOLD J32100

DOOR STOP & HOLDER

1 WEATHER STRIP

(ROY 165 FOR HEAD/ JAMB

ROY 415 FOR SILL)

KICK PLATE J102, SST

CLOSER C020212

1 ADJUSTABLE ASTRAGAL

FLUSH BOLT L040812

3.

APPROVAL

AND WINDOW SCHEDULE AND DETAIL DRAWING TO COR FOR

CONTRACTOR SHOULD SUBMIT SHOP DRAWING FOR ALL DOOR

CONNECTED TO STRUCTURE WITH ANCHOR BOLT AND WELDING.

ALL EXTERIOR DOOR FRAME AND WINDOW FRAME SHOULD BE

AND UFC 4-010-01, PAG B-9 & 10, PARA B-3.1 THRU B-3.1.4

ALL EXTERIOR DOOR, GLAZED WINDOW: SEE SEPC SECTION 08391;

1.

2.

FABRICATION AND INSTALLATION

SHALL BE APPROVED BY THE CONTRACTING OFFICER BEFORE

DOORS AND ALUMINUM WINDOWS AS ACTUAL SIZE, AND DRAWINGS

THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL

DOOR & WINDOW NOTES

HIGH QUALITY AND GRADE PRODUCTS WITH APPROVAL TO COR.

& QUALITY ARE NOT REQUIRED. BUT CONTRACTOR SHOULD INSTALL

AN EXACT MATCH OF THE MANUFACTURERS FUNCTION, GRADE, COLOR,

AND ARE NOT INTENDED TO LIMIT SELECTIONS OF PRODUCTS.

MANUFACTURERS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY

SCHEDULE AND HARDWARE SCHEDULE

& COLOR SCHEDULE, DOOR & WINDOW

INTERIOR FINISH SCHEDULE, MATERIAL

LEVER TYPE

LOCKSET 1000-1, F-07

STEEL TUBE

ON EXST

STORAGE EP COATING EP-1 VCB VCB F.F. VCB-1 - MTL - PAINT PT-2 VARIOUS

AL 1200 800- -

AND FRAME W/ INSECT SCREEN

FIXED AL LOUVER (45°BLADES)

HOOK & EYEBOLT

WALL TYPE BUMPER L02101

(2 EA)

CONC)

GALV STEEL

80x80x3.2 THK

YELLOW STRIPS

BLACK BACKGROUND

TUBE (FILLED W/

50 x 50 x 6THK

FOUNDATION

STEEL PLATE

CONCRETE

170 x 170 x 6THK

WELDED TO

STEEL TUBE

DOOR

STEEL TUBE

50 x 50 x 6 THK STEEL

80x80x3.2 THK

WALL TYPE BUMPER L02101

GALV STEEL TUBE

(FILLED W/CONC)

PLATE WELDED TO

EYEBOLT

HOOK &

PT-1 : PAINT

LATEX / SEMI-GROSS

NOROO, #NR7073

OR APPROVED EQUAL

PT-2 : PAINT

ALKYD, SEMI-GLOSS

FOR EXISTING STL COLUMN,

BEAM, PURLIN, GIRTS, CRANE FRAME

NOROO, #NK7073

OR APPROVED EQUAL

: EPOXY COATING SYSTEM

SIKA-KOREA, EPOXY, CONFORMED LEED LOW VOC,

PRIMING - SIKA FLOOR 161

1ST COAT - SIKA FLOOR 263SL (2mm)

2ND COAT : SIKA FLOOR 263SL (3mm)

W/ NON-SLIP

LIGHT GREY (APPROVED BY USER)

OR APPROVED EQUAL

EP-1 VCB-1 : VINYL COVE BASE

DARK BROWN

100 HGT x 3 THK

OR APPROVED EQUAL

METAL DOOR

HARDWARE

MANUFACTURERS STANDARD MUST APPROACH.

TO INDICATE THE COLOR WHICH THE

IS NOT REQUIRED. THE SELECTIONS SERVE ONLY

AN EXACT MATCH OF THE MANUFACTURERS COLOR

INTENDED TO LIMIT SELECTIONS OF PRODUCTS.

IDENTIFICATION PURPOSES ONLY AND ARE NOT

MANUFACTURERS' COLORS LISTED ARE FOR

(STORAGE S-237 & 238)

REPAIR OPERATION FACILITES IN AHA 23

A-1

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE: N/A

1/50

REPAIR / MAINTENANCE (K) WORK

1.

2.

3.

4.

SCOPE OF WORK (ARCHITECTURAL WORK)

THE GUTTER & TO MEET AT/FP REQUIREMENTS.

3. TO PREVENT LEAVES FROM COLLECTING IN

2. INSTALL REMOVABLE METAL SCREEN

AT ALL GUTTERS.

SHOULD NOT BE EXCEEDED MAX 12,000mm.

1. DISTANCE BETWEEN GUTTER EXPANSION JOINTS

*NOTE

SOLDER

RIVET &

GUTTER

SLOPE

1/16 PER FT

SECTION A-A

1/16 PER FT

SLOPE

SCALE: N/A

FRONT 12 LOWER

THAN BACK (MIN)

GUTTER LAP

ENDS

MET GUTTER

SLOPE

A

A

WATER TIGHT

ENCLOSURE W/ SEAL

PROTECTED

15019

GUTTER EXPANSION DETAILS

EXISTING METAL ROOFING

WATERPROOFING ON

3,9634,2673,962

,0

,0

12,192

,0

PICTURES

GROUND FLOOR PLAN

PAINT ON ALL STEEL STRUCTURES AS SHOWN…