H1_Drawing_files___185600___ARHC.PDF
PDF 3 MB Posted
- Attached to
- Replace fire alarm system and Building Transceiver (BT) for buildings on west side of Camp Casey.
- Solicitation number
- W91QVN-18-R-0137
About this file
ARHC
View the file
Other files
| File | Type | Posted |
|---|---|---|
| H1_Drawing_files___185600___CIVIL.PDF | ||
| H1_Drawing_files___185600___STRU.PDF | ||
| H1_Submittal_Register___185600.xls | XLS spreadsheet | |
| H1_Drawing_files___185600___ELEC.PDF | ||
| RFP_for_W91QVN18R0137.docx | DOCX document | |
| H1_Drawing_files___185600___Title.pdf | ||
| H1_Drawing_files___185600___MECH.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-1
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
MANUFACTURES INDICATED.
PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE
COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.
ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).
CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS
FOR APPROVAL.
CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR
CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE
SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD
8.
FOR APPROVAL.
CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR
2.
3.
4.
5.
6.
7.
CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER.
IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT, THE GENERAL
AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION
OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE.
APPROPRIATE TEMPORARY SUPPORTS SHOULD BE CONSTRUCTED PRIOR TO DEMOLITION
9.
10.
11.
12.
13.
14.
NUMBERS ARE FROM TM-5-807-7 AND FEDERAL STANDARD NO. 595b, COLORS.
COLOR OF MATERIALS & PAINTS SHALL BE SELECTED BY USING AGENCY AND COLOR
DETAILS AND GET APPROVAL FROM COR. BEFORE FABRICATION AND INSTALLATION.
CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR/WINDOW
ADDITIONAL COST TO THE GOVERNMENT.
EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM WITHOUT
THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING, HEATING,
ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE REQUIRED FOR
THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVE/REINSTALL ANY OBSTRUCTED
GENERAL NOTES
SPECIFICATION 15181.
ITEMS REQUIRING MAINTENANCE/OPERATION IAW THE SECTION 3.1.14, OMA STD
PROVIDE ACCESS DOORS FOR ALL CONCEALED VALVES, VENTS, CONTROLS AND OTHER
COMMENCEMENT OF FLOOR TILE WORK AND AS PER FLOOR FINISH SCHEDULE.
ALL CONCRETE FLOOR SURFACES SHALL BE LEVELED AND SMOOTHED PRIOR TO
OFFICE, DPW. PER DIRECTION FROM THE INSPECTOR IN CHARGE OR COR.
SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE
AND GENERAL NOTES
EXST & NEW GROUND FLOOR PLANS
1.67 K. SM/W
3.34 K. SM/W
AS FOLLOWS :
WALL
ROOF
"R" VALUE FOR INSULATION SHALL BE
& COATING.
REMOVE & CLEAN EXISTING PAINT BY SAND PAPER/ GRINDING FOR NEW PAINTING
FROM THE MANUFACTURE SHOWING THE PRODUCT IS LEAD FREE.
A CERTIFICATE OR MATERIAL SAFETY DATA SHEET (MSDS), WRITTEN IN ENGLISH,
SOLIDS) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR WILL PROVIDE
COATINGS WITH LESS THAN 0.05 PERCENT LEAD BY WEIGHT OF THE NON-VOLATILE
THE CONTRACTOR IS REQUIRED TO USE "LEAD FREE" COATINGS (LIQUID PAINTS OR
15.
16.
17.
18.
DOCUMENTATION TO 8 CES/CEAN.
THE CONTRACTOR SHALL PROVIDE THE NEW SURVEY REPORT AND ASBESTOS REMOVAL
ACCORDANCE WITH THE KOREA ENVIRONMENTAL GOVERNING STANDARD (KEGS).
PRIOR TO ANY WORK TO ASSURE THAT APPROPRIATE ASBESTOS CONTROL IS IN
AREA WILL NEED TO BE RESURVEYED AND ASBESTOS MATERIALS SHOULD BE REMOVED
WORK IN THE AFFECTED AREA AND NOTIFY THE CONTRACTING OFFICER. THE WORK
ASBESTOS CONTAINING MATERIAL ARE DISCOVERED, THE CONTRACTOR SHALL CEASE
IS NOT PRESENT IN THE AREAS AFFECTED BY THIS WORK: HOWEVER, IF SUSPECTED
VERIFYING THE PRODUCT IS ASBESTOS FREE. TESTS HAVE INDICATED THAT ASBESTOS
WILL PROVIDE A CERTIFICATE OR MSDS, WRITTEN IN ENGLISH, FROM THE MANUFACTURER
PERCENT BY WEIGHT) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR
THE CONTRACTOR IS REQUIRED TO USE "ASBESTOS FREE" MATERIALS (LESS THAN 0.1
BEDROOM
LAUNDRY
MECH ROOM
CORRIDOR
VEST
VEST
101 BEDROOM 102 BEDROOM 103 BEDROOM 104
107 BEDROOM 106 BEDROOM 105
L/S
W
D
FECB/B
DASHED LINE FOR
ROOF(ABOVE)
BED/LIV ROOM BED/LIV ROOM BED/LIV ROOM BED/LIV ROOM
BED/LIV ROOMLAUNDRY
MECH ROOM
CORRIDORVEST VEST
SCALE: 1 : 100
EXST GROUND FLOOR PLAN
SCALE: 1 : 100
NEW GROUND FLOOR PLAN
33,934
8,5858,3828,3828,585
,1
,8
,5
,8
33,934
8,5858,3828,3828,585
,8
,1
,8
,5
,8
8,5858,8903,8612,6429,957
BEDROOM
W1
L3
L1L2
D1 D3
D7
D8 D3 D1
D2
D4
D4 D4 D4 D4
D4D4
D5
D6
D6
D5
D5 D5 D5
D5D5
D6 D6
D6D6 D6
DAYROOMSTORAGE
SHALL BE AS A PART OF THE CONTRACT DOCUMENT OF THIS PROJECT.
STANDARD DETAIL DRAWINGS FOR O&MA PROJECT, KOREA, DATED NOVEMBER 2015
BED/LIV ROOM
W1 W1 W1 W1 W1 W1
W1 W1 W2 W1 W1 W1 W1
W
W/CMU, RE-BAR & EIFS
BLOCK UP DOOR OPNG
/CCTV
COMM CLOSET
YI, SC
185600
BUILDING S-81, CP CASEY
BUILDING TRANSMITTERS AND REPAIR
REPLACE FIRE ALARM SYSTEM / INSTALL
BEDROOM
LAUNDRY
MECH ROOM
CORRIDOR
VEST VEST
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
TYP
SB SB SB SB
SB
SB
SB
1 PER 2001 PER 200
GUTTER SLOPE
GUTTER EXPANSION JOINT
GUTTER SLOPE 6
DS
STANDING SEAM
METAL ROOFING
GEJ GEJDS DS DSDS GEJ
GEJDS DSGEJ
DS
DS GEJ DS
DS DS
F M
F M
F M
F M
F M
F M
A-2
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
CEILING ACCESS DOOR
DETECTOR
(SEE ELECTRICAL DRAWINGS)
CEILING EXHAUST FAN
(SEE MECHANICAL DRAWINGS)
(600x600 or 450x450)
ACST CLG
GWB CLG
PROTECTED METAL SOFFIT
1HR FIRE RATED WALL
(SEE ELECTRICAL DRAWINGS)
LIGHTING FIXTURE
FIRE ALARM SPEAKER
(SEE ELECTRICAL DRAWINGS)
LEGEND
VTR
GOOSENECK
(SEE MECH DWG)
SMOKE STACK
(SEE MECH DWG)
EXHAUST FAN
SB
F M
ROOF PLAN AND CEILING PLAN
60033,934600
,6
,8
,6
17,4753,86112,598
,1
,6
,8
,6
600 600
CURTAIN BOX
SCALE: 1 : 100
NEW ROOF PLAN
SCALE: 1 : 100
CEILING PLAN
BEDROOM
A-9
A-9
A-9
A-9
A-11
A-11
/CCTV
COMM CLOSET
YI, SC
185600
BUILDING S-81, CP CASEY
KEY PLAN
1ST FL
WORK POINT
1ST FL
WORK POINT
A-3
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
ELEVATIONS
STANDING SEAM
METAL ROOFING
PROTECTED
MET GUTTER
INSULATED BLAST
SLIDING AL WINDOW
(TYP)
THERMAL INSULATED
METAL DOOR
EIFS ON EXISTING
PROTECTED
MET FLASHING
EIFS ON EXISTING
CMU WALL
THERMAL INSULATED
PROTECTED
MET FLASHING
AIR INTAKE
LOUVER (TYP)
BUILDING
IDENTIFICATION
S-81
PROTECTED
MET FLASHING
STANDING SEAM
METAL ROOFING
PROTECTED
MET GUTTER
INSULATED BLAST
SLIDING AL WINDOW
(TYP)
EIFS ON EXISTING
CMU WALL
PROTECTED
MET FLASHING
EIFS ON EXISTING
CMU WALL
STANDING SEAM
METAL ROOFING
BUILDING
IDENTIFICATION
S-81
PROTECTED MET
DOWNSPOUT
SCALE:
1 : 100
NEW ELEVATION-1
SCALE:
1 : 100
NEW ELEVATION-2
SCALE:
1 : 100
NEW ELEVATION-4
SCALE:
1 : 100
NEW ELEVATION-3
CMU WALL (TYP)
A-11
BLAST METAL DOOR
A-11
YI, SC
185600
BUILDING S-81, CP CASEY
A-4
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
SCOPE OF WORKS (ARCHITECTURAL WORK)
REPAIR / MAINTENANCE (K) WORK
1.
2.
3.
4.
6.
7.
8.
9.
5.
SIGNAGE SCHEDULE.
REPLACE INTERIOR & EXTERIOR SIGNAGES WITH NEW FOR ALL ROOMS AS SHOWN ON
ON NEW FLOOR PLANS AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING FIRE EXTINGUISHER CABINET(FEC) WITH NEW AS SHOWN
11.
12.
13.
14.
15.
16.
17.
18.
HARDWARE SETS AS SHOWN ON NEW FLOOR PLANS AND DOOR SCHEDULE.
REPLACE DETERIORATED EXISTING DOORS AND DOOR FRAMES WITH NEW INCLUDING NEW
TYPE.
REPLACE DETERIORATED EXISTING WINDOW HORIZONTAL MINI BLINDS WITH NEWS, FIREPROOF
19.
20.
21.
22.
FLOOR PLANS AND FINISH SCHEDULE.
WATER RESISTANT OR 'X' TYPE) CEILING INCL. CEILING SUSPENSION SYSTEM AS SHOWN ON
REPLACE DETERIORATED EXISTING CEILING WITH NEW GYPSUM WALL BOARD (GWB, NORMAL,
SLAB IF NEEDED.
CORRECTED FOR NEW FLOORING. PROVIDE LEVELING CONCRETE FOR EXISTING CONCRETE
CONCRETE, LOW SPOTS, HIGH SPOTS, PAINTING, AND UNEVEN SURFACE SHALL HAVE BEEN
SHALL BE SMOOTH, TRUE, LEVEL PLANE WITH ALL DEFECTS SUCH AS ROUGH OR SCALING
ON FLOOR PLAN & INTERIOR FINISH SCHEDULE. THE EXISTING CONCRETE FLOORING
REPLACE DETERIORATED EXISTING FLOOR TILE WITH NEW PVCT INCLUDING VCB AS SHOWN
SCHEDULE.
PAINT ON ALL INTERIOR SURFACES INCL CEILING & WALL AS SHOWN ON INTERIOR FINISH
10.
SOUND PROOF INSULATIONS (STC 45) AS SHOWN ON FLOOR PLANS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING ALL GWB WALLS WITH NEW INCLUDING METAL STUDS AND
REPLACE EXISTING CHAIR RAILS WITH NEW IN CORRIDOR AS SHOWN ON DETAIL DRAWING.
ROOM AS SHOWN ON FLOOR PLAN.
REPLACE DETERIORATED EXISTING METAL SHELF WITH MOP RACK WITH NEW IN LAUNDRY
SUSPENSION SYSTEMS AS SHOWN ON INTERIOR FINISH SCHEDULE.
REPLACE DETERIORATED EXISTING CEILING WITH NEW ACOUSTICAL CEILING TILE INCL. METAL
HARD & DETAIL MESHES AND FINISH COATING AS SHOWN ON FLOOR PLAN AND ELEVATIONS.
REPLACE DETERIORATED EXISTING EIFS ON EXST EXTERIOR CMU WALL WITH NEW INCLUDING
DETAIL DRAWINGS.
REPLACE EXISTING ALUMINUM LOUVERS WITH NEW AS SHOWN ON FLOOR PLANS AND
AS SHOWN ON FLOOR PLANS AND WINDOW SCHEDULE.
+ 12 THK AIR SPACE + 6 THK TINTED LOW-E TEMPERED GLASS ( SHGC : MAX 0.4 )
THERMAL BREAKER TYPE BLAST WINDOWS INCLUDING 8.75 THK CLEAR LAMINATED GLASS
REPLACE DETERIORATED EXISTING WINDOWS INCL INSECT SCREEN WITH NEW ALUMINUM
FLOOR PLAN AND ELEVATIONS.
REPLACE DETERIORATED EXISTING CONCRETE STOOPS AND STEPS WITH NEW AS SHOWN ON
AS SHOWN ON FLOOR PLAN AND DETAIL DRAWINGS.
REPLACE RAIN GUTTERS AND DOWNSPOUTS WITH NEW INCLUDING CONCRETE SPLASH BLOCKS
AND DETAIL DRAWINGS.
WATERPROOFING, MORTAR BEDS AND CEMENT BOARDS AS SHOWN ON FLOOR PLANS
REPLACE DETERIORATED EXISTING FCT AND GCWT(FULL HEIGHT) WITH NEW INCL.
WOODEN CURTAIN BOX WITH NEW AS SHOWN ON DETAILS. (NATURAL COLOR, OAK)
REPLACE DETERIORATED EXISTING WOODEN HEAD, JAMB & SILL FOR ALL WINDOWS AND
REPLACE DETERIORATED EXISTING SHELVE WITH NEW SST SHELVE IN LAUNDRY ROOM.
FLOOR PLAN AND DETAIL DRAWINGS.
REPLACE WOODEN CLOSET SHELF AND SST COAT ROD IN EACH CLOSET AS SHOWN ON
DETAIL DRAWINGS.
REPLACE EXISTING ALL TOILET ACCESSORIES WITH NEW AS SHOWN ON FLOOR PLAN AND
AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING ACCESS DOORS WITH NEW AS SHOWN ON CEILING PLAN
23.
24.
25.
26.
CABINET AS SHOWN ON FLOOR PLANS AND DETAIL DRAWINGS.
REPLACE EXISTING DETERIORATED KITCHENETTE INCLUDING BASE CABINET AND UPPER
AND DETAIL DRAWINGS.
REPLACE BULLETIN BOARD AND PLEXI-INFO HOLDER WITH NEW AS SHOWN ON CEILING PLAN
LINER PANEL AS SHOWN ON ROOF PLAN AND DETAIL DRAWINGS.
INCLUDING INSULATION, PROTECTED METAL FLASHING AND GALVANIZED METAL ROOF
REPLACE DETERIORATED EXISTING ROOF WITH NEW STANDING SEAM METAL ROOFING
LAUNDRY MECH ROOM
BEDROOM
BEDROOM
105111112
BATHRM BATHRM BATHRM
1ST FL
TOP OF CONC
CORR
109107 101
1ST FL
WORK POINT
CORR
109 102
MECH ROOM
KEY PLAN
6008,5858,8903,8612,6429,957600
6009,144600
3,8101,5243,810
,1
60010,994600
3,8101,2704,0641,850
,1
,5
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
EXTERIOR INSUL &
FINISH SYSTEM ON
EXISTING CMU WALL
PROTECTED
METAL
FLASHING
EXISTING CONC
SLAB TO REMAIN
(REMOVE EXISTING
FLOOR FINISH)-TYP
FILL NFSM W/ VB
(SEE STRL
DWG)-TYP
BEDROOM BEDROOM
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
PROTECTED
METAL GUTTER
PROTECTED
METAL
DOWNSPOUT
BEDROOM
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
COMM
NFSM 1200 HGT
(TYP)
SCALE:
1 : 100
LONGITUDINAL SECTION
SCALE:
1 : 100
CROSS SECTION-1
SCALE:
1 : 100
CROSS SECTION-2
BEDROOM
CMU GUARD WALL FOR CHILLER AS SHOWN ON PICTURES.
PAINT ON ALL EXISTING EXTERIOR EXPOSED SURFACES OF OTHER COMPONENTS SUCH AS
ACM REMOVAL NOTES
1.
2.
3.
REGION OFFICE.
THE ARMY, INSTALLATION MANAGEMENT AGENCY, KOREA
DATED 14 JANUARY 2014, ISSUED BY THE DEPARTMENT OF
TECHNICAL SPECFICATIONS FOR OMA PROJECTS, KOREA",
02 82 14/ASBESTOS HAZARD CONTROL ACTIVITIES, STANDARD
THE ASBESTOS REMOVAL WORKS SHALL CONFIRM TO "SECTION
ACM AT THE WORK SITE.
ENVIRONMENTAL OFFICE THRU COR TO COMPLETE REMOVAL
THE CONTRACTOR SHALL CONTACT AND VERIFY TO
WORK SITE.
LOAD ASBESTOS CONTAINING MATERIAL REMOVED FROM THE
EPA (ENVIRONMENTAL PROTECTION AGENCY) TO COR FOR EVERY
THE CONTRACTOR SHALL SUBMIT A CERTIFICATION OF DISPOSAL,
27.
- PIPE HANGING IN MECH ROOM, 1EA
- GASKET IN MECH ROOM, 1EA
- JOINT VERTICAL IN MECH ROOM, 1EA
REMOVE EXISTING ASBESTOS CONTAINING MATERIALS AS ACM REMOVAL NOTES.
AND ACM REMOVAL NOTES
SECTIONS, SCOPE OF WORK
CLOSET/CCTV
YI, SC
185600
BUILDING S-81, CP CASEY
A-5
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
152 MET STUD WALL
203 MET STUD WALL
LEGEND
92 MET STUD WALL
200 THK CONC WALL
EIFS ON EXISTING CMU WALL
SCALE: 1 : 50
15 THK GWB ON
C-100x50x20x2.3 @ 400 OC
92 MET STUD WALL
(1HR FIRE RATED & STC 50 W/ 90
THK SOUNDPROOF INSUL)
BEDROOM
LAUNDRY
MECH ROOM
CORRIDORVEST
VEST
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
108 109
FECB/B
BATH ROOM BATH ROOM
CLOSET
CLOSET
CLOSET CLOSET
CLOSETCLOSETCLOSET
REF REF REF
REF REFREF REF
BATH ROOM BATH ROOM
BATH ROOM BATH ROOM
BATH ROOM
DASHED LINE FOR
ROOF(ABOVE)
D
C
B
A
TYP
33,934
8,5858,3828,3828,585
6101,6262,0321,6267,1121,6262,8451,6261,6261,6265,6901,6262,0321,626610
,1
1,300
8,5858,8903,8612,6429,957
4061,4221005004,2771,6262,0321,626610 6101,6262,0321,6265,8931,6262,0321,626406
1,5851,0003,7003,7001,0003,6823,6821,0003,7003,7001,0001,5852,300
1,4111,9005501,4421,0002003,7041,0002,953
5001,900200700561
2,6001,261
,8
,5
,8
,6
2,300
COMM
15 THK GWB ON 38
FURRING CHANNEL ON
EXISTING CMU WALL
15 THK GWB ON 38
FURRING CHANNEL ON
EXISTING CMU WALL
15 THK GWB ON 38
FURRING CHANNEL ON
EXISTING CMU WALL
15 THK GWB ON 38
FURRING CHANNEL ON
EXISTING CMU WALL
15 THK GWB ON 38
FURRING CHANNEL ON
CONC WALL
DASHED LINE
FOR AIR INTAKE
LOUVER (TYP)
ENLARGED FLOOR PLAN
ENLARGED FLOOR PLAN
A-6
A-6
A-6
A-6
BEDROOM
A-11
L/S
W
D
W
CLOSET/CCTV
2003,461200
YI, SC
185600
BUILDING S-81, CP CASEY
REFREF
WCLAV
TB
SHD
SH
TTD
WCLAV
TB
SHD
SH
TTD
B
GCWT
SINKREF
(GFGI)
PAINT
GWB
MICRO WAVE
(GFGI)
GCWT
GCWT
PAINT GWB
REF
(GFGI)
D
C
B
A
D
C
B
A
D
C
B
A
D
C
B
A
SC/R
WC
SH
SHD
LAV
GCWT-1 (TYP)SHD
VCBA C D A B C D
TTD
B
4 1 3
GCWT
SINKREF
(GFGI)
PAINT
GWB
MICRO WAVE
(GFGI)
GCWT
PAINT GWB
REF
(GFGI)
VCBA C D
WC
SH
SHD
LAVA B C D
TTD TTD
SOAP HOLDERSH
WC WATER CLOSET
TOILET TISSUE DISPENSERTTD
TB TOWEL BAR
MG MIRROR GLASS
LAV LAVATORY
ABBREVIATION
SC/R SHOWER CURTAIN ROD
SHOWER HEADSHD
REF REFRIGERATOR
LIGHT SWITCH
203 MET STUD WALL
LEGEND
92 MET STUD WALL
VERIFY DIM.
GCWT
T B
TOWEL BAR
TOWEL BAR
SC/R
GCWT-1 (TYP)SHD
DOOR TO
CORRIDOR
A B
D L/S
DRYER(GFCI)
(TYP)
WASHER
(GFCI) (TYP)
GCWT
W
C D
FCU
GCWT
SHOWER CURB
MOP RACK
A-6
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
SHELF & ROD
200 1400
INTERIOR ELEVATIONS
TYPICAL PARTIAL PLANS AND
WC
780 960
750450450
1650800
780 1460 650
450 450 750
C L
G H
G T
VERIFY DIM
VERIFY DIM
C L
G H
G T
0 M
G
L A
V
S H
T T
D
S C /R
T B
C L
G H
G T
VERIFY DIM
VERIFY DIM
C L
G H
G T
0 M
G
L A
V
T T
D 0 S
H
T B
0S C /R
T T
D
C L
G H
G T
M O
P R
A C
K
ELECTRIC
RANGE
(GFGI)
HOOD
(SEE MECH
DWG)
DASHED LINE FOR
LIGHTING ON SSM
(SEE ELEC DWG)
SHOWER CURTAIN
W/ ROD
OPEN TO
BEDROOM
ELECTRIC
RANGE
(GFGI)
HOOD
OPEN TO
BEDROOM
SHOWER CURTAIN
W/ ROD
DASHED LINE FOR
LIGHTING ON SSM
(SEE ELEC DWG)
92 MET STUD WALL
(1HR FIRE RATED & STC 50 W/ 90
THK SOUNDPROOF INSUL)
SSM TRIM
SSM TRIM
SSM TRIM
SSM TRIM
SCALE: 1 : 50
TYP PARTIAL PLAN-BATHRM 2
SCALE: 1 : 50
TYP PARTIAL PLAN-BATHRM
A-6 A-6
SCALE: 1 : 50
CLOSET PARTIAL PLAN
A-5
SCALE: 1 : 50
SCALE: 1 : 50
INTERIOR ELEVATION (BED ROOM-1) INTERIOR ELEVATION (BATH ROOM-1)
A-6 A-6
SCALE: 1 : 50
INTERIOR ELEVATION (BED ROOM-2) 7
SCALE: 1 : 50
INTERIOR ELEVATION (BATH ROOM-2)
A-6 A-6
SCALE: 1 : 50
INTERIOR ELEVATION (LAUNDRY)
A-5
SST SHELF
A-6
A-6 A-6
A-6
A-12
A-11
A-10 A-10
A-12 A-12 A-12A-12
A-10
A-10
MC
TB MCTB
MC
MC
MC
TB
TB
SC
SC
(GFGI) (GFGI)
W
YI, SC
185600
BUILDING S-81, CP CASEY
1A
1B
1C
1D
1E
1ST FL
WORK POINT
MECH ROOM
BEDROOM
1ST FL
WORK POINT
CORRIDOR
V A
R
1ST FL 1ST FL
TOP OF CONC
VEST
CORRIDOR
1ST FL
A-7
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
SCALE: 1 : 30
WALL SECTIONS-1
WALL SECTIONS-1
C L
G H
G T
C L
G H
G T
C L
G H
G T
BEDROOM
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
FINISH PER
SCHEDULE
INSULATED
BLAST AL
WINDOW
PROTECTED
METAL GUTTER
PROTECTED
MET FLASHING
PROTECTED MET
SOFFIT
PAINT
15 THK GWB
ON C-100x50x20x2.3
@ 400 OC
FINISH PER
SCHEDULE
GALV METAL
ROOF LINER
THERMAL
INSULATED
METAL DOOR
GALV METAL
ROOF LINER
STANDING SEAM
METAL ROOFING
W/ INSUL
GALV METAL
ROOF LINER
FINISH PER
SCHEDULE
EIFS ON
CONC WALL
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
CONC
STOOP
FINISH PER
SCHEDULE
PAINT
15 THK GWB
ON 38 FURRING
CHANNEL @ 400 OC
HDR ON CONC
EXISTING CONC
SLAB TO
REMAIN(TYP)
2% SLOPE
NFSM
0.5 THK
COPPER
FLASHING
EIFS ON 12 THK
CEMENT BOARD
ON C-100x50x20x2.3
STL CHANNEL
@ 400 OC
PROTECTED
METAL FLASHING
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
GALV METAL
ROOF LINER
THERMAL INSULATED
BLAST METAL DOOR
12 THK GWB ON
C-100x50x20x2.3 STL
CHANNEL
@ 400 OC
FINISH PER
SCHEDULE
FINISH PER
SCHEDULE
CONC
STOOP
EIFS ON 12 THK
CEMENT BOARD
ON C-100x50x20x2.3
STL CHANNEL
@ 400 OC
PROTECTED
METAL FLASHING
VAPOR BARRIER
ON NFSM
(SEE STRL DWG)-TYP
SIDE WALK
(SEE CIVIL
DWG)
2% SLOPE
FINISH PER
CURTAIN BOX
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
PROTECTED
METAL GUTTER
PROTECTED
MET FLASHING
PROTECTED MET
SOFFIT
EIFS ON
EXISTING WALL
GALV METAL
ROOF LINER
BATHROOM
SHOWER
AREA
GCWT ON THINSET MORTAR
ON 12 THK CEMENT BOARD
ON 203 MET STUD @ 400 OC
(MAX)
PAINT 15 THK GWB ON BOTH SIDE OF
1HR FIRE RATED WALL(SEE NOTE)
(STC 50 MIN. W/ ACOUSTICAL/FIRE
SEALANT @ BOTTOM TOP OF WALL &
PENETRATIONS)
FINISH PER
SCHEDULE
PAINT 12 THK
WATER
RESISTANT
GWB
FINISH PER
90 THK GLASS FIBER INSUL
(30 kg/m²)
1A 1B 1C 1D
1E
A-9
A-11
A-10
A-9
NOTE :
1HR FIRE RATED WALL:
-15 THK TYPE "X" GWB OF BOTH SIDE
ON 92 MET STUD @ 400 OC (MAX)
WOOD SILL
OAK (TYP)
WOOD HEAD
OAK (TYP)THERMAL
SCHEDULE
SCHEDULE
NFSM
EIFS ON EXST
CMU WALL
PROTECTED MET
FLASHING
WOOD JAMB OAK
OAK (TYP)
GCWT ON THINSET MORTAR
(ON WATER PROOFING MEMBRANE,
FULL HEIGHT @ SHOWER AREA ONLY)
ON EXISTING CMU WALL(TCNA, W211-13)
FCT ON CEMENT MORTAR BED
(ON WATER PROOFING MEMBRANE
@ SHOWER AREA ONLY)
ON CONC SLAB (TCNA, F121-13)
GCWT ON THINSET MORTAR
(ON WATER PROOFING MEMBRANE, FULL
HEIGHT @ SHOWER AREA ONLY)
ON 12 THK CEMENT BOARD ON 203 MET STUD
(TCNA, W244C-13)
FM WP 45 (GA FILE NO WP1072)
YI, SC
185600
BUILDING S-81, CP CASEY
1B
1A
1C
1D
1B
CORR
109MECH ROOM
111 113
MECH ROOM
BEDROOM
BEDROOM
(S
C /R
MECH ROOM
BEDROOM
A-8
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURALSCALE: 1 : 30
WALL SECTIONS-2
WALL SECTIONS-2
C L
G H
G T
C L
G H
G T
C L
G H
G T
C L
G H
G T
COMM
SHOWER
AREA
PAINT 12 THK
WATERRESISTANT
GWB
GALV METAL
ROOF LINER
FINISH PER SCHEDULE
HDR ON
CONC
BATH
ROOM
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
GALV METAL
ROOF LINER
GALV METAL
ROOF LINER
PAINT ON 15 THK GWB ON BOTH
SIDE OF 1 HR FIRE RATED WALL
(SEE NOTE)
(STC 45 MIN. W/ ACOUSTICAL/FIRE
SEALANT @ BOTTOM TOP OF WALL
& PENETRATIONS)
FINISH PER
SCHEDULE
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
FINISH PER
SCHEDULE
EXISTING CONC
SLAB TO
REMAIN(TYP)
VAPOR BARRIER
ON NFSM
(SEE STRL DWG)-TYP
FINISH PER
12 THK CEMENT
BOARD ON 1HR FIRE
RATED WALL
(SEE NOTE)
90 THK GLASS FIBER INSUL
(30 kg/m²)
FIRE STOPPING
W/ FIRE SEALANT
GALV METAL
ROOF LINERGALV METAL
ROOF LINER
FIRE STOPPING
W/ FIRE SEALANT
CONC WALL
(1 HR FIRE RATED WALL)
CONC WALL
(1 HR FIRE RATED WALL)
HDR ON
CONC
LAUNDRY
PAINT 15 THK GWB
ON 38 FURRING
CHANNEL @ 400 OC
FIRE STOPPING
W/ FIRE SEALANT
CONC WALL
(1 HR FIRE
RATED WALL)
HDR ON
CONC
PAINT ON 15 THK GWB
ON 92 METAL STUD @ 400 OC
(STC 45 MIN. W/ ACOUSTICAL/FIRE
SEALANT @ BOTTOM TOP OF WALL
& PENETRATIONS)
PAINT GALV
METAL ROOF
LINER
1A 1B 1C
1D
A-10
NOTE :
1HR FIRE RATED WALL:
-15 THK TYPE "X" GWB OF BOTH SIDE
ON 92 MET STUD @ 400 OC (MAX)
SCHEDULE
C L
G H
G T
FM WP 45 (GA FILE NO WP1072)
GCWT ON THINSET MORTAR
(ON WATER PROOFING MEMBRANE, FULL
HEIGHT @ SHOWER AREA ONLY)
ON 12 THK CEMENT BOARD
(TCNA, W244C-13)
ON 1 HR FIRE RATED WALL(SEE NOTE)
(STC 45 MIN. W/ ACOUSTICAL/FIRE SEALANT
@ BOTTOM TOP OF WALL & PENETRATIONS)
GCWT ON THINSET MORTAR
ON 12 THK CEMENT BOARD
(TCNA, W244C-13)
ON 152 METAL STUD @ 400 OC
FCT ON CEMENT MORTAR BED
ON WATER PROOFING MEMBRANE
ON CONC SLAB (TCNA, F121-13)
CLOSET/CCTV
YI, SC
185600
BUILDING S-81, CP CASEY
A-9
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
1.
NOTES :
0.25 THK POLYETHYLENE SHEET VAPOR RETARDER SHALL BE PROVIDED OVERLAP
& SEAL W/ SELF ADHESIVE AIR BARRIER AT JOINT & PENETRATION.
GALV
MET ROOF LINER
VAPOR RETARDER
INSULATION
GALV
SEALANT
SEALANT
MET F
LASHIN
G
MECH EQUIPMENT
(SEE MECH DWG)
OUTLINE OF
W/CRICKET
P.M FLASHING
M
IN
18 GA GALV MET CURB W/
100 FLANGE (ALL AROUND)
50x150 TREATED WOOD
P.M BASE FLASHING
P.M CAP FLASHIG
METAL ROOFING
STANDING SEAM
BLOCKING NAILER
CURB OPENING
(ALL AROUND OUTSIDE OF CURB)
RIGID INSULATIONCONNECT DUCT
INSUL ON VR
(TYP)
METAL ROOF LINER
METAL TRIM
CLOSURE
18 GA "Z"
CLOSURE
METAL ROOFING
STANDING SEAM
INSERT SCREEN
PROTECTED MET
W/MET FRAME
& FASTENERS
CAP FLASHING
FLASHING
EPDM PIPE
M
IN
VENT PIPE
GALV MET TRIM
INSUL OB VR
(SEE MECH DWG)
SEAM
STANDING
ROOF LINER
GALV MET
MET ROOFING
METAL ROOF LINER
INSUL ON VR
WORKING POINT
"Z" CLOSURE
GLAV
GLAV
PROTECTED METAL
RAKE FLASHING
MASTIC STANDING SEAM
MET ROOFING
INSULATION
GALV
METAL ROOF LINER
INSUL ON VR
STANDING SEAM
MET ROOFING
PROTECTED METAL
FLASHING
300300
EXTERIOR INSUL
& FNSH SYSTEM
PROTECTED MET
DOWNSPOUT
PAINT
15 THK GWB
ON C-100x50x20x2.3
@ 400 OC
25Wx3THK BRACKET
HANGER @ 900
OC(MAX)
(STAGGERED W/
STRAP HANGERS)
PROTECTED MET
WATER DRIP
PROTECTED MET SOFFIT
ON C- 100x50x20x2.3 W/
INSUL ON VR
SEALANT W/
BACKER ROD
PROTECTED MET GUTTER
(SEE INTO BRACKET
HANGER)
METAL STRAP HANGER @
900 OC (MAX)
(RIVER TO GUTTER EDGE)
CONTINUOUS METAL
EDGE STRIP
25 THK THERMAL
SPACER BLOCK
STANDING SEAM
MET ROOFING
PROTECTED MET
SOFFIT
ON C-100x50x20x2.3
@ 400 OC
SEALANT W/
BACKER ROD
PROTECTED MET
WATER DRIP
EXTERIOR INSUL &
FNSH SYSTEM
ON 12 THK CEMENT BOARD
ON C-100x50x20x2.3
@ 400 OC
CONC BOND BEAM
(SEE STRL DWG)-TYP
VAPOR
RETARDER
ON GALV MET
ROOF LINER
EIFS CONTROL JOINT W/
SEALANT & BACKER ROD
CEILING
(SEE FINISH SCHEDULE)
PAINT
15 THK GWB
ON 38 FURRING
CHANNEL @ 400 OC
CONC BOND BEAM
(SEE STRL DWG)-TYP
CEILING
(SEE FINISH
SCHEDULE)
"Z" CLOSURE
(MIN
http://youtu.be/hUNupHDgHa4
SCALE: 1 : 10A-2
ROOF EAVE DETAIL-1 2
SCALE: 1 : 10A-2
ROOF EAVE DETAIL-2
SCALE: 1 : 10A-2
METAL CURB DETAIL
SCALE: 1 : 10A-2
ROOF EDGE DETAIL 5
SCALE: 1 : 10A-2
VENT THRU ROOF DETAIL
SCALE: 1 : 10A-2
ROOF VALLEY DETAIL
EAVE FL
ASHING
25 200
MIN
150 150
EAVE FL
ASHING
ROOF DETAILS
YI, SC
185600
BUILDING S-81, CP CASEY
A-10
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
2A
2C
13 THK SOLID SURFACING
PLYWOOD (COUNTER TOP & BACK )
MATERIAL (SSM-1) ON 18 THK
SEALANT
20x100
WD SHIM
WD SHIM
20x100
2B
2D
C L
G
H
T
20X100 WD
(SEE ELEC DWG)
LIGHTING
MIRROR ON 7.5 THK PLYWD
POST-FORMED 13 THK
SOLID SURFACING MATERIAL
ON 7.5 THK PLYWD
MARINE EDGE
ON 18 THK PLYWOOD
PLASTIC LAMINATE (PL-1)
10 DIA POLISHED BRASS ROD
PULL @ EACH DOOR (B02011)
ON 7.5 THK PLYWOOD(FRONT)
PLASTIC LAMINATE (PL-2)
W/ HINGE (2PR-BO1602
@ EACH DOOR)
PLASTIC LAMINATE (PL-2)
ON 18 THK PLYWOOD
(TOP & EDGE)
(FRONT, BACK & EDGE)
1B
1C
1A SCALE : 1/10
LAV BOWL
(SEAMED UNDERMOUNT)
5B
5A
SECTION
P L A N
FEILD TILE )
( COLOR TO MATCH
PORCELAIN SOAP HOLDER
CERAMIC TILE
WATERPROOF MEMBRANE
SOAP HOLDER
CERAMIC TILE
PORCELAIN
WATERPROOFING MEMBRANE
CEMENT MORTAR
ON METAL LATH
W/6 DIA TOGGLE
ON WATERPROOFING
6 THK CEMENT BOARD
TOWEL BAR
FLANGE
TOWEL BAR
GCWT ON
BOLT
MEMBRANE ON
CONNECTED METAL
METAL CHANNEL
STUD
METAL STUD
@ 406 OC
4 THK BENT
W/ 6 DIA EXP BOLTS
@ 300 OC
SST BASE (WELDED)
R=5
12 THK SSM
SEALANT
WATER PROOFING
MEMBRANE
SHOWER AREABATH ROOM
SHOWER CURTAIN
2C
2B
2D
2A
L-50x50x6x50LG STL
PLASTIC LAMINATED (PL-2)
ON 18 THK PLYWD(TOP)
ON 7.5 THK PLYWD
PLASTIC LAMINATED (PL-2)
FIXED TO WD BLOCK &
50x100 WD
BLOCK
SILICONE SEALANT
30x50 HARDWD
18X18 HARDWD TRIM
W/ PLASTIC LAMINATED
POST-FORMED 13 THK
ON 18 THK PLYWOOD
MARINE EDGE
(FRONT, BACK & EDGE)
PLASTIC LAMINATED (PL-1)
ON 18 THK PLYWD
SOLID SURFACING (SSM-1) MATERIAL
50x100 WD BLOCK
WD BLOCK & TO
CONC SLAB W/
6DIA EXP BOLTS
@ 450 OC
L-50x50x6x50LG STL
CLIP FIXED TO
18 x 18
PLASTIC LAMINATED (PL-2)
ON 18 THK PLYWD
PLASTIC
PLYWD
& EDGE)
ON 7.5 THK PLYWOOD
PLASTIC LAMINATED
ON 18 THK PLYWOOD
POST-FORMED 13 THK
SOLID SURFACING (SSM-1) MATERIAL
(FRONT)
HARDWD TRIM
ON 18 THK
LAMINATED (PL-1)
(FRONT, BACK
W/ PLASTIC
LAMINATED (PL-1)
(TOP & EDGE)
MIRROR ON 7.5 THK PLYWD
WATER PROOFING
EXP BOLT @ 450 OC
TO CONC SLAB W/6 DIA
SEAL W/ BOLT
FOR WATER PROOFING
SEAL W/ BOLT
FOR WATER PROOFING
7.5 THK PLYWOOD
W/ GLUE
6 THK MIRROR ON
6 THK MIRROR ON
MATERIAL
SURFACING
13 THK SOLID
POST-FORMED
SEALANT
W/ GLUE
7.5 THK PLYWOOD
SST FRAME
12 THK CEMENT
BOARD
BOARD
12 THK CEMENT
SST FRAME
POST-FORMED
13 THK SOLID
SURFACING
MATERIAL
SEALANT
1C
1B SCALE : 1/2
SCALE : 1/2
SEALANT
BASE FLASHING
PROTECTED MET
PROTECTED
METAL
"Z" CLOSURE
T O
F
EIFS ON 12 THK
CEMENT BOARD
ON C-100x50x20x2.3
STL CHANNEL
@ 400 OC
100 THK TREATED
WD NAILER
80x80x7.0THK STEEL
ANGLE FRAME
@ 850 OC
METAL STRAP HANGER
@ 900 OC (MAX)
(RIVER TO GUTTER EDGE)
PROTECTED MET GUTTER
(SEE INTO BRACKET
HANGER)
25 W x 3 THK
BRACKET HANGER @
900 OC(MAX)
(STAGGERED W/
STRAP HANGERS)
PROTECTED MET
SOFFIT
C-100x50x20x2.3
W.P
STANDING SEAM
METAL ROOFING
CANOPY
EAVE FL
ASHING
SCALE:A-6
TYP LAVATORY COUNTER DETAIL
AS SHOWN
SCALE:A-6
SHOWER CURB DETAIL
1:5
SCALE:A-6 1:10
TOWEL BAR DETAIL 5
SCALE:A-6 1:10
SOAP HOLDER DETAILS
SCALE:A-10 1:5
D E T A I L S 6
SCALE:A-7 1:5
CANOPY DETAIL
A-10
A-10
A-10
A-10
A-10A-10
MISC DETAILS-1
12 THK CEMENT BOARD
12 THK CEMENT BOARD
COAT
THINSET MORTAR
THINSET MORTAR
BOND COAT
GCWT W/CEMENT
GCWT W/ CEMENT BOND
YI, SC
185600
BUILDING S-81, CP CASEY
A-11
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
THE GUTTER & TO MEET AT/FP REQUIREMENTS.
3. TO PREVENT LEAVES FROM COLLECTING IN
2. INSTALL REMOVABLE METAL SCREEN AT ALL GUTTERS.
SHOULD NOT BE EXCEEDED MAX 12,000mm.
1. DISTANCE BETWEEN GUTTER EXPANSION JOINTS
SECTION A-A
NOTE
SECTION A-A
MET. GUTTER
CONTINUOUS
A
CLEAT
MET. ROOFING
CLEAR
SLOPE
1:200
RIVET &
SOLDER
GUTTER
GUTTER LAP
ENDS
A
SLOPE
SLOPE
1:200
THAN BACK (MIN)
FRONT 12 LOWER
4B SECTION
& FINISH SYSTEM
EXT INSUL
FILL GROUT
FL LEVEL
& FINISH SYSTEM
EXT INSUL
AL SHEET FLASHING
SEALANT
SSTL PLATE
5 THK BENT
4B
4A ELEVATION
& FINISH SYSTEM
EXT INSUL
SSTL PLATE
5 THK BENT
FL LEVEL
DASHED LINE FOR
(BEYOND)
LOUVER
(SEE MECH DWG)
ELEVATION
O
U T S
ID
E
R
IM
D
IN
S
B
X
(INSIDE BOX DIM)
1B
(OUTSIDE TRIM DIM)
METAL
DOOR PULL
METAL FIRE
CABINET
EXTINGUISHER
PLEXIGLASS
METAL TRIM
L
IN
S
PULL
SIDE)
METAL DOOR
6 DIA METAL
SCREW (3-PER
SCHEDULE
FLAT TRIM
FINISH PER
(ALL AROUND)
WOOD SHIM
R
O U
P
E N
IN
G
1C SECTION
1A PLAN
(INSIDE BOX DIM)
(OUTSIDE TRIM DIM)
(INSIDE BOX DIM)
1C 1B
FLAT TRIM
IN
S
WOOD SHIM
(ALL AROUND)
DOOR PULL
CASING BEAD
(TYP)
(ROUGH OPENING)
1HR FIRE RATED
WALL
ON 92 MET STUD
15 THK GWB
@ 400 OC
3B
WOOD FRAME
EXSTING CMU WALL
EXP BOLTS
BULLETIN BOARD
RADIUS(3 MIN-TYP)
(HEAD, JAMB & SILL)
3 THK MET CLIP
@ 450 OC W/6 DIA
O O
R
SECTION
SCALE: 1/2
(NATURAL FINISH)
BULLETIN BOARD
WOOD FRAME
(NATURAL FINISH)
ELEVATION
SCALE: NONE
3A
FL
150 1910
T O
F F
L
(TYP)
(TYP)
@ 900 OC
METAL DS
(150 x 100)
1.5 THK X 50 W
DS STRAP HANGER
@ 900 OC (MAX)
PROTECTED METAL
EXT INSUL & FNSH SYSTEM
PROTECTED
9 DIA EXP BOLT
SST PLATE
3THKx50W
SST STRAP
75Wx150Hx5THK
CMU WALL
6 DIA CAP
W/WASHER (TYP)
CAP SCREW & NUT
RUST PROOF
SEALANT
PAINT 15 THK GWB
ON 92 METAL STUD
@ 400 OC
12 THK SSM
R=5
GCWT ON
ON 12 THK
CEMENT BOARD
25 THK WOOD TRIM
SEALANT
PAINT 15 THK GWB ON BOTH SIDE OF
(STC 45 MIN. W/ ACOUSTICAL/FIRE
SEALANT @ BOTTOM TOP OF WALL &
PENETRATIONS)
90 THK GLASS FIBER INSUL
(30 kg/m²)
L-150x150x6 THK
W/12 DIA BOLTS & NUTS
@ 450 OC
19 THK OAK WD
(NATURAL FINISH)
SEALANT(TYP)
30 300 30
4545 300
SCALE:A-5 1:10
FIRE EXTINGUISHER CABINET DETAIL
SCALE:A-7 1:2
CURTAIN BOX DETAILS
SCALE:A-5 1:2
BULLETIN BOARD DETAILS
SCALE:A-3 1:10
AIR INTAKE LOUVER DETAILS
SCALE:A-6 1:2
SSM TRIM DETAIL
SCALE:A-3 1:5
DOWNSPOUT HANGER DETAIL 6
SCALE:A-2 N/A
GUTTER EXPANSION JOINT DETAILS
MISC DETAILS-2
1HR FIRE RATED WALL
(SEE MATERIAL SCHEDULE
BB-1 , A-13)
CEMENT BOND COAT
CONC WALL
YI, SC
185600
BUILDING S-81, CP CASEY
CEILING LINE
PULL @ EACH DOOR
(B02011) 10 DIA POLISHED
C
T
20x100
(TYP)
WD SHIM
PLASTIC LAMINATE (PL-1)
(TOP,BOTTOM, & EDGE)
ON 18 THK PLYWOOD
REF (GFGI)
7.5 THK PLYWOOD (FRONT)
PLASTIC LAMINATE (PL-2)
(B04071 & B04081)
PLASTIC LAMINATE (PL-2)
PLASTIC LAMINATE (PL-2)
ON 18 THK PLYWOOD
ON 18 THK PLYWD
PLASTIC LAMINATE(PL-2)
MET ADJ SHELF HARDWARE
(TOP,BOTTOM & EDGE)-TYP
(BOTTOM & EDGE)-TYP
2PR - B01602 @ EACH DOOR)-TYP
(FRONT, BACK & EDGE W/HINGES
PLASTIC LAMINATE (PL-1) ON 18 THK PLYWD
ON 7.5 THK PLYWOOD (FRONT)-TYP
PLASTIC LAMINATE (PL-1)
PULL @ EACH DOOR
(TOP,BOTTOM, & EDGE)-TYP
ON 18 THK PLYWOOD
LIGHTING FIXTURE (SEE ELEC DWG)
(B02011) 10 DIA POLISHED BRASS ROD
18 THK PLYWOOD
ON METAL STUD WALL
ON 12 THK CEMENT BD
MARINE EDGE
13 THK SOLID SURFACE
MATERIAL (SSM-1) OVER
KITCHEN SINK
(SEE MECH DWG)
(COUNTERTOP, BACK &
SIDE SPLASH)
ON 18 THK PLYWOOD
PLASTIC LAMINATE (PL-1)
10 DIA POLISHED BRASS ROD
PULL @ EACH DOOR (B02011)
25X50 WD
VCB
ON 7.5 THK PLYWOOD(FRONT)
PLASTIC LAMINATE (PL-2)
W/ HINGE (2PR-BO1602
@ EACH DOOR)-TYP
PLASTIC LAMINATE (PL-2)
ON 18 THK PLYWOOD
BOLTS @600 OC
X50 LG W/ 12DIA EXP
50X100 WD & 50X50X6
(TOP & EDGE)-TYP
(FRONT, BACK & EDGE)
20x100
(TYP)
WD SHIM
5D
5C
PULL @ EACH DOOR
(B02011) 10 DIA POLISHED BRASS ROD
7.5 THK PLYWOOD (FRONT)
PLASTIC LAMINATE (PL-2)
ON 18 THK PLYWD
PLASTIC LAMINATE (PL-2)
(TOP,BOTTOM & EDGE)
MICROWAVE(GFGI)
PLASTIC LAMINATE (PL-1)
(TOP,BOTTOM, & EDGE)
ON 18 THK PLYWOOD
ON METAL STUD WALL
ON 12 THK CEMENT BD
BOLTS @600 OC
X50 LG W/ 12DIA EXP
50X100 WD & 50X50X6
C
T
20x100
(TYP)
WD SHIM
5D
VCB
5B
5A
18 THK PLYWOOD
(COUNTERTOP, BACK &
13 THK SOLID SURFACE
MATERIAL (SSM-1) OVER
SIDE SPLASH)
MARINE EDGE
@ EACH DOOR
PULL
PLASTIC LAMINATE (PL-2)
ON 7.5 THK PLYWOOD
(TOP, BOTTOM & EDGE)
METAL
ADJUSTABLE
25X50 WD
PLASTIC LAMINATE (PL-2)
ON 18 THK PLYWOOD
BRASS ROD
CEILING LINE
PLASTIC LAMINATE (PL-1)
ON 18 THK PLYWOOD (FRONT)-TYP
50x100 WD FRAME (TYP)CEILING LINE
PLASTIC LAMINATE (PL-1)
ON 18 THK PLYWOOD (FRONT)-TYP
50x100 WD FRAME (TYP)
C
T
(FRONT)
CEILING LINE
RANGE HOOD
(SEE MECH DWG)
PULL @ EACH DOOR
(B02011) 10 DIA POLISHED
C
T
20x100
(TYP)
WD SHIM
PLASTIC LAMINATE (PL-1)
(TOP,BOTTOM, & EDGE)
ON 18 THK PLYWOOD
ON METAL STUD WALL
ON 12 THK CEMENT BD
GCWT ON THINSET MORTAR
7.5 THK PLYWOOD (FRONT)
PLASTIC LAMINATE (PL-2)
BRASS ROD
50x100 WD FRAME (TYP)
PLASTIC LAMINATE (PL-1)
ON 18 THK PLYWOOD (FRONT)
ON METAL STUD WALL
ON 12 THK CEMENT BD
GCWT ON THINSET MORTAR
ON 12 THK CEMENT BD
5C
5B 5D
5A
L-50x50x6x50LG STL
PLASTIC LAMINATED (PL-2)
ON 18 THK PLYWD(TOP)
ON 7.5 THK PLYWD
PLASTIC LAMINATED (PL-2)
EXP BOLT @ 450 OC
FIXED TO WD BLOCK &
TO CONC SLAB W/6 DIA
50x100 WD
BLOCK
SILICONE SEALANT
30x50 HARDWD
18X18 HARDWD TRIM
W/ PLASTIC LAMINATED
POST-FORMED 13 THK
ON 18 THK PLYWOOD
MARINE EDGE
(FRONT, BACK & EDGE)
PLASTIC LAMINATED
ON 18 THK PLYWD
SOLID SURFACING (SSM-1)
DRAWER STOPPER
20x40 HARD WD
W/ PLASTIC
LAMINATED
(TOP)
ON 7.5 THK PLYWD
PLASTIC LAMINATED (PL-2)
50x100 WD BLOCK
WD BLOCK & TO
CONC SLAB W/
6DIA EXP BOLTS
@ 450 OC
L-50x50x6x50LG STL
CLIP FIXED TO
18 x 18
VCB
PLASTIC
PLYWD
& EDGE)
ON 7.5 THK PLYWOOD
ON 18 THK PLYWOOD
POST-FORMED 13 THK
SOLID SURFACING (SSM-1) MATERIAL
(FRONT)
HARDWD TRIM
ON 18 THK
LAMINATED (PL-1)
(FRONT, BACK
W/ PLASTIC
LAMINATED (PL-1)
(TOP & EDGE)
MATERIAL
(PL-1)
A-12
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
SCALE:A-6 1:10
CABINET DETAIL 2
SCALE:A-6 1:10
CABINET DETAIL
SCALE:A-6 1:10
UPPER CABINET DETAIL 4
SCALE:A-6 1:10
UPPER CABINET DETAIL
SCALE:A-12 1:5
D E T A I L S
SCALE:A-6 1:5
TYP SHELF & ROD DETAILS @ CLOSET
PLASTIC LAMINATED (PL-2)
A-12 A-12
A-12
A-12
A-12
CABINET DETAILS AND SHELF DETAIL
GCWT ON CEMENT BOND COAT GCWT ON CEMENT BOND COAT
GCWT ON CEMENT BOND COAT
PLASTIC LAMINATE (PL-1)
HANGING ROD
4 DIA HOLE (TYP)
CLOTHES
25 DIA SST PIPE
-25x25x2
2.5 THK SST
BRACKET
O O
R
HANGING ROD
SST BRACKET
CLOTHES
2.5 THK
25 DIA SST PIPE
-25x25x2 SST BRACKET
POSTFORM
22x200 WOOD
1.6 THK SST SOCKET
CLOTHES HANGING ROD
25 DIA SST PIPE
R
5 50
0 50
9 DIA TOGGLE BOLTS
PAINT GWB
PAINT CMU
BOTH SIDES-SHELF & SIDE PANEL
ON 18 THK PLYWD
PLASTIC LAMINATE (PL-1)
ON 18 THK PLYWD
@ 300 O.C
SEE DETAIL
@ 900 OC
@ 900 OC
100350
6A 6B
6C
@ 900 OC
6C
BOLTS
9 DIA TOGGLE
YI, SC
185600
BUILDING S-81, CP CASEY
O O
R
@ 600 O.C
20 THKx90
OAK CHAIR RAIL
CHAIR RAIL DETAIL
RADIUS
(3 MIN-TYP)
FACE OF WALL
SCALE : N/A
A-13
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
2.
1.
FOR SUBMITTAL REQUIREMENTS AND SPECIFIC ITEMS TO BE PAINTED.
SCHEDULE. SEE SPECIFICATION SECTION 09915 : EXTERIOR AND INTERIOR COLOR SCHEDULE
COLOR DESIGNATION SHALL BE AS INDICATED IN THE EXTERIOR AND INTERIOR FINISH COLOR
WITH THE CAMP CASEY EXTERIOR COLOR SCHEME AS APPROVED BY THE COR.
SELECTION OF EXTERIOR PAINT AND FACTORY APPLIED COLORS SHALL BE IN ACCORDANCE
MANUFACTURERS STANDARD MUST APPROACH.
COLOR IS NOT REQUIRED. THE SELECTIONS SERVE ONLY TO INDICATE THE COLOR WHICH THE
INTENDED TO LIMIT SELECTIONS OF PRODUCTS. AN EXACT MATCH OF THE MANUFACTURERS
MANUFACTURERS' COLORS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY AND ARE NOT 3.
4.
ROOM NAMESROOM NOS
INTERIOR FINISH SCHEDULE
FLOOR BASE WALLS CEILING
REMARKS
FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT
SURFACE
ROOFING
FLASHING
FASCIA
SOFFIT
DOOR & FRAME
HANDRAIL
MATERIAL
STEEL
STEEL PIPE
COLOR
CHOCOLATE
COLOR NO.
20095
CHOCOLATE
CHOCOLATE
CHOCOLATE
CHOCOLATE
CHOCOLATE
20095
20095
20095
20095
20095
REMARKS
WALL EIFS
WALL CMU
BEAM/COL CONC
CONC
SAND-STONE
SAND-STONE
SAND-STONE
SAND-STONE
23617
23617
23617
23617
PROTECTED METAL
EXTERIOR COLOR SCHEDULE-1
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
PT-1
MATERIAL & COLOR SCHEDULE
FLOOR MATERIAL/COLOR BASE MATERIAL/COLOR
WALL MATERIAL/COLOR
GCWT-1
PT-2
CEILING MATERIAL/COLOR
PVCT-1
OR APPROVED EQUAL
457.2MMx457.2MM, 3MM THK
KCC SENSE TILE, CERAMIC, TN2412C
PVC TILE
FCT-1
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
NEW
MAT'L
EXST
USER AGENCY.
SELECTION OF INTERIOR PAINT AND FACTORY APPLIED COLORS SHALL BE APPROVED BY
SHALL BE WATERPROOF TYPE GWB.GWB FOR TOILETS, AND OTHER WET AREAS 5.
101 THRU 107
BATH ROOM
BED ROOM VCBVCT PVCT
CMT FCT --
VCBF.F.
F.F.
PVCT-1
FCT-1 -
F.F.
VCB-1
GCWT
GWB PAINT
F.F.
PT-1
GWB GWB* PAINT
PAINT
PT-2
PT-2
GCWT GWB GWB* 2450
- - VAR
VCT GWB PAINT PT-1 GWB
F.F. PVCT-1 GWB GWB 2450
VCT
PVCT
PVCT
PVCT-1F.F.
VCB VCB F.F. VCB-1
VCB VCB F.F. VCB-1
F.F.
GWB
ACST
ACST
PAINT PT-2
GWB* : FIRE RETARDANT TYPE
FINISH SCHEDULE NOTES
VCT GWB PAINT PT-1PVCT PVCT-1F.F. VCB VCB F.F. VCB-1 GWB*
F.F. PVCT-1 CONC GWBVCT PVCT VCB VCB F.F. VCB-1 PAINT PT-1
WOOD
GWB* : WATERPROOF TYPE
GWB* : FIRE RETARDANT TYPE
GWB* : WATERPROOF TYPEFCT F.F. FCT-1 - - -
GWB* : FIRE RETARDANT TYPE
GWB* : FIRE RETARDANT TYPEF.F. ACST-1
ACST-1
OR APPROVED EQUAL
WHITE
MC 3102 (3S)
"KCC MITONE"
603MM x 603MM x 15MM THK
ACOUSTICAL CEILING TILE
STAIR WALLS
CORRIDOR
MECH ROOM
VEST
LAUNDRY
VEST
COMM CLOSET
112 -
HDR F.F. HDR-1
F.F. ACST-1
GWB 2450ACST F.F. ACST-1
GWB* PAINT PT-2 3000 GWB* : FIRE RETARDANT TYPE
CDA-300, CLEAR COATING
HDR-1
NOROO, DENSIL
OR APPROVED EQUAL
HARDENER
1200W x 900H
BB-1
MEDIUM GREY
POSTER PANEL: FABRICORK
FRAME: FINE WOOD
OR APPROVED EQUAL
MISC MATERIAL/COLOR
BULLETIN BOARD
PROTECTED METAL
PROTECTED METAL
PROTECTED METAL
OR APPROVED EQUAL
NON-SLIP, 300 x 300 x 8 THK
FG 7L67-1, MARON
DONGSEO, INUS
FLOOR CERAMIC TILE
OR APPROVED EQUAL
300 x 600 x 10 THK
LQR IN92-1, GLOSS
DONGSEO, INUS
GLAZED CERAMIC WALL TILE
GCWT-1
GCWT-1
KITCHEN CABINET NOTE
(PL-1).
PLYWD PANEL W/ PLASTIC LAMINATE
CONSTRUCTED OF SOLID WD TRIMS &
END PANEL AND ETC. SHALL BE
INCLUDING DOOR, DRAWER FRONTS, SIDE
ALL EXPOSED COUNTER CABINET FACES
5.
6.
(PL-2).
FINISHED W/ PLASTIC LAMINATE
ALL CABINET INSIDE SURFACE SHALL BE
7.
PL-1:
BY FORMICA OR APPROVED EQUAL.
7737-58, NATURAL CHERRY, MATTE
PLASTIC LAMINATE, COLOR:
PL-2:
BY FORMICA OR APPROVED EQUAL.
756-58, NATURAL MAPLE, MATTE
PLASTIC LAMINATE, COLOR:
SSM-1:
EQUAL.
MOSAIC BY FORMICA OR APPROVED
SOLID SURFACE, COLOR #651, CHICORY
FOR THE SOUND SILENCE.
EQUIPPED WITH RUBBER BUMPER
ALL CABINET DOORS SHALL BE
AND TO BE INSTALLED BY OTHER.
GOVERNMENT FURNISHED MATERIALS
MICROWAVE,RANGE AND REFRIGERATOR WILL BE 1.
2.
3.
4.
FINISHED W/ SOLID SURFACE MATERIAL (SSM-1).
ALL CABINET COUNTERTOP SHALL BE
8.
TWO (2) INCHES ACTURAL SIZE OF THE REF.)
JOB SITE, (REFRIGERATOR SPACE SHALL BE
AND CABINET SIZE WILL BE ADJUSTED ON THE
REFRIGERATOR DIMENSION IS APPROXIMATE SOLID SURFACE MATERIALS FOR APPROVAL.
OF HARDWARE, PLYWOOD, PLASTIC LAMINATE &
AND TEST REPORTS, CERTIFICATIONS
OF KITCHEN CABINETS WITH HARDWARE,
CONTRACTOR SHOULD SUBMIT SHOP DRAWING
& COLOR SCHEDULE AND NOTES
INTERIOR FINISH SCHEDULE, MATERIAL
NOROO, NR7066
OR APPROVE EQUAL
PAINT LATEX/ EGGSHELL
ARCHITECTURAL LATEX/ SEMIGLOSS
OR APPROVE EQUAL
NOROO, NR7066
PAINT HIGH PERFORMANCE
GCWT
SELECTED BY USING AGENCY.
PLASTIC LAMINATED COLOR TO BE
GCWT
PAINT PT-1GWB*
VCB-1
OR APPROVED EQUAL
DARK BROWN, 100 HGT, 3THK
LG HAUSYS
VINYL COVE BASE
: MOLD & MILDEW RESISTANT, STAIN PROOF
ANTIQUE WHITE
OR APPROVED EQUAL
ARDEX FG 4
* EPOXY GROUT COLOR FOR GCWT AND FT
GWB*
GWB*
GWB*
YI, SC
185600
BUILDING S-81, CP CASEY
A-14
ARCHITECTURAL
REMARKS
DOOR DIMENSION
WIDTH
MATERIAL
D1 B
DOOR
TYPE
DOOR
NOS.
ROUGH OPENING
WIDTH HEIGHT
HDW
SET
THICKHEIGHT NO (HR)
RATED
FIRE
LOUVERGLAZING
CUT
UNDER
FRAME
D2
D3
D4
D
D5
D - -
D6
D7
D
D8 E STEEL
STEEL 7
DOOR
12001626ALGLASSF - -------
STL HOLLOW CORE DOOR
C W/ STL FRAME
D
WOOD SOLID DOOR
BW/ STL FRAMEA
INSULATED STL DOOR
KEY BOX : WALL MOUNTED KEY BOX E83513.
COORDINATING WITH THE USER FOR APPROVAL BY COR.
THE CONTRACTOR SHALL SUBMIT MASTER KEYING CHART, 4.
5.
6.
8.
9.
7.
HEAT GAIN AND FIRERATED.
WHITE OR LIGHT BEIGE TO MAXIMIZE REFLECTANCE AND MINIMIZE
BE EQUIPPED WITH HORIZONTAL MINI BLINDS. COLOR SHALL BE
WINDOWS IN ALL AREAS WHERE FUNCTIONALLY WARRANTED SHALL
1.
2.
INSECT SCREEN SHOULD BE EQUIPPED TO ALL EXTERIOR WINDOWS.
NATURAL COLOR FINISH W/ QUARTER SLICED OAK.
ALL WOOD FLUSH DOORS SHALL BE FINISHED FACTORY COATED
10.
MANUFACTURER'S LISTED INSTRUCTIONS.
INSTALLED IN ACCORDANCE WITH NFPA 80 OR THE DOOR
INSTALLATION INSTRUCTIONS. FIRE RATED DOORS SHALL BE
TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER
DOOR FRAMES & FIRE RATED GLASS. FIRE RATED DOOR FRAMES
ALL FIRE RATED DOORS SHALL BE INSTALLED IN FIRE RATED
FABRICATION AND INSTALLATION
SHALL BE APPROVED BY THE CONTRACTING OFFICER BEFORE
DOORS AND ALUMINUM WINDOWS AS ACTUAL SIZE, AND DRAWINGS
THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL
12.
2133STEEL STEEL 1000 2200 914 44.5 - -1
A STEEL 44.5 - -2
44.5 -3
E STEEL -6
STEEL -5
W/ STEEL FRAME
FACTORY FINISH
W/ QUARTER SLICED OAK
C
(2 EA)
P L A N
DOOR
S E C T I O N
STEEL TUBE
CONC STOOP
WELDED TO
STEEL PLATE
50 x 50 x 6THK
FOUNDATION
STEEL PLATE
STEEL TUBE
CONCRETE
170 x 170 x 6THK
WELDED TO
EYEBOLT
HOOK &
DOOR
HOOK & EYEBOLT
STEEL TUBE
CONC)
GALV STEEL
80x80x3.2 THK
50 x 50 x 6 THK STEEL
80x80x3.2 THK
WALL TYPE BUMPER L02101
GALV STEEL TUBE
(FILLED W/CONC)
PLATE WELDED TO
WALL TYPE BUMPER L02101
YELLOW STRIPS
BLACK BACKGROUND
TUBE (FILLED W/
1 DOOR STOP & HOLDER DETAILS
250X250
HARDWARE SCHEDULE & NOTES
DOOR / WINDOW SCHEDULE, ELEVATIONS,
GLASS VISION
PANEL AS
SCHEDULE
STEEL
W1
DOOR & WINDOW NOTES
HIGH QUALITY AND GRADE PRODUCTS WITH APPROVAL TO COR.
& QUALITY ARE NOT REQUIRED. BUT CONTRACTOR SHOULD INSTALL
AN EXACT MATCH OF THE MANUFACTURERS FUNCTION, GRADE, COLOR,
AND ARE NOT INTENDED TO LIMIT SELECTIONS OF PRODUCTS.
MANUFACTURERS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
DOOR / WINDOW / LOUVER SCHEDULE DOOR/ WINDOW / LOUVER ELEVATIONS
HARDWARE SCHEDULE
21331800 2200 1714STEEL
21331000 2200 914
STEEL
35.521331400 2200 1314
WOOD 2133800 2200 714
44.521331800 2200 1714
44.521331000 2200 914
44.521331000 2200 914
F
FIXED
HDW-4
THRESHOLD J32100
DOOR STOP L02161
KICK PLATE J102, SST
CLOSER CO2011
1 DOOR VIEWER LO3221
3 HINGES A5111 114X114, NRP
SOUND PROOF SEAL1
ROY 265 (FOR HEAD & JAMB)
WOOD
STEEL
G AL 300AL 700 - - - - - - - -L1
WOOD* 1/3 * SOUNDPROOF WOODEN DOOR, STC-25 MIN
G
HDW-1
WEATHER STRIP
THRESHOLD J321001
HINGES A5112, 114x114, NRP
1 DOOR CLOSER CO2021
EXIT DEVICE TYPE-3, F08
(ROY 154 FOR HEAD/JAMB)
ROY 414 FOR SILL)
1 KICK PLATE J102, SST
(LEVER TYPE HANDLE)
HINGES A5112 114x114, NRP
LOCKSET 1000-1, F07
FLUSH BOLTS L04081
1 ASTRAGAL
1 WEATHERSTRIP
(ROY 165 FOR HEAD/ JAMB,
ROY 415 FOR SILL)
HDW-2 (MECH)
HDW-3
DOOR STOP LO2161
KICK PLATE J102, SST1
HINGES A5112, 114x114, 1 DOOR CLOSER CO2011
THRESHOLD J321001
(INT ENT.)
AUTOMATIC DOOR BOTTOM ROY 3351
(UNIT ENT)
HDW-6
DOOR STOP LO21412
HINGES A5112, 114x114
2 MAGNETIC DOOR LATCH
ROD TYPE DOOR PULL
(CLOSET)
HINGES A5112 114X114
THRESHOLD
DOOR STOP L02161
HDW-5
(LEVER TYPE HANDLE)
(SOLID SURFACE MATERIAL)
(NEAR THE HINGE)
(BATHRM)
HINGES A5112 114x114
HDW-8
LOCK SET 1000-1, F071
2 DOOR STOP L02141
(LEVER TYPE HANDLE)
(COMM)
FLUSH BOLTS L040812
HDW-7
DOOR STOP LO2161
KICK PLATE J102, SST1
HINGES A5112, 114x114
1 DOOR CLOSER CO2011
LOCKSET 1000-1, F01
THRESHOLD J321001
(LEVER TYPE HANDLE)
(LAUNDRY)
WOOD
150x750
1)
E
WOOD SOLID DOOR
W/ STEEL FRAME
FACTORY FINISH
W/ QUARTER SLICED OAK
WOOD
3/4
- 1/3
150x750
1)
1) FIRE RATED / LAMINATED GLASS
44.5
150x750
1)
1) INSULATED / LAMINATED GLASS
1) LAMINATED GLASS
12001422ALGLASSF - -------W2
G AL 700AL 700 - - - - - - - -
G AL 200AL 400 - - - - - - - -
1DOOR STOP & HOLDER
1DOOR STOP & HOLDER
PULL PLATE J405
PUSH PLATE J301
19MM
LOCKSET F76
(EXT ENT)
GLASS VISION
PANEL AS
SCHEDULE
THERMAL INSULATED
BLAST METAL DOOR
W/ METAL FRAME
: 40.6 KPA
- PEAK IMPULSE
: 210 KPA-MS
PRESSURE
- PEAK REFLECTED
(ANODIZED DARK BRONZE)
AL BLAST WINDOW
(THERMAL BREAK TYPE)
SLIDING
W/ INSECT SCREEN
- PEAK REFLECTED PRESSURE
: 40.6 KPA
- PEAK IMPULSE
: 210 KPA-MS
( SHGC : MAX 0.4 )
+ 6 THK TINTED LOW-E TEMPERED GLASS
+ 12 THK AIR SPACE
: 8.75 THK CLEAR LAMINATED GLASS
TYPICAL INSULATED/LAMINATED GLASS FOR WINDOWS
MINI-BLIND AND INSECT SCREEN
MINI-BLIND AND INSECT SCREEN
( SHGC : MAX 0.4 )
+ 6 THK TINTED LOW-E TEMPERED GLASS
+ 12 THK AIR SPACE
8.75 THK CLEAR LAMINATED GLASS
W/ INSECT /BIRD SCREEN
AND FRAME
FIXED AL LOUVER (45° BLADES)
LAMINATED GLASS : 8.75 THK CLEAR LAMINATED GLASS
VERIFY FIRE RATED GLASS W/ LAMINATED GLASS.11.
L2
L3
-4EA OF AA BATTERIES PER EACH LOCKSET
INTO USING AGENCY
-ADDITIONALLY 20% OF BLANK CARD KEYS SHOULD BE TURNED
-O&M TRANING TO DPW BY MANUFACTURER
-MASTER KEY SYSTEM
-CARD KEYED TYPE WITH 3EA CARD KEYS & PROGRAM
-SELF LOCKING
ONITY, MAGSTRIPE HT24 OR APPROVED EQUAL
ELECTRONIC CARD KEYED LOCKSET,
ELECTRONIC CARD
KEYED LOCKSET WITH BATTERY
(LEVER TYPE HANDLE)
OR APPROVED EQUAL
- WDMA TM-8 HINGE LOADING TEST METHOD
- WDMA TM-7 CYCLE SLAM TEST METHOD
2014 O&MA SPECIFICATIONS.
INDICATED ON SECTION 08 14 00, WOOD DOORS,
SHALL SUBMIT CERTIFICATIONS AND TEST REPORTS FOR APPROVAL AS
ALL WOOD DOORS SHOULD BE TESTED AS FOLLOWING,AND CONTRACTOR 13.
YI, SC
185600
BUILDING S-81, CP CASEY
A-15
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
BUILDING IDENTIFICATION LAUNDRY
1A 2C 2B1C
M E S S A G E DETAILELEVATION QUANTITY R E M A R K S
ELEVATIONM E S S A G E R E M A R K SDETAIL QUANTITY
IDENTIFICATION
1B 2A,2B
COORDINATED WITH THE CONTRACTING
1. SIGN MESSAGE COPY WILL BE
OFFICER AND USING AGENCY
BY THE SITE ADAPT CONTRACTOR
NOTE
BROWN
BACKGROUND
LETTERS
WHITE
NOTE : ROOM NUMBERS SHALL BE AS
SHOWN ON FLOOR PLAN
FIN. FL
FINISH SYSTEM
EXT.INSUL &
STEEL BOLT
8 PER SIGN
ALUM. SLEEVE
MASTIC
COMPOUND
6 THK ALUM PLATE
WOOD NAILER W/
50 W x T, 1,200
Laundry
AND BULLETIN BOARD SCHEDULE
NOTE : FOR ALTERNATE MESSAGE SEE SIGNAGE
WHITE LETTERS
BACKGROUND
BROWN
FIN. FL
C A
P
1220012
75224
1220112
A1
A1
A1A1
A1
A1
BED ROOM
2B1C
A1 A1
CORRIDOR
SIGNAGE SCHEDULE AND DETAILS
1B1A
2B
BUILDING IDENTIFICATION
NOT TO SCALE
D E T A I LD E T A I L
SIZE, MOUNTING LOCATION & DETAILS OF SIGNAGE
1C
2C2A D E T A I L
A1 A1 A1
A1A1A1
1&2
DOUBLE EMULSION
FOAM TAPE
PICTOGRAPH
LETTERS &
ALL AROUND
POLISH EDGES
ACRYLIC BACKING
BOARD W/SCREW
@ WALL ONLY
(DO NOT USE
@ FIRE-RATED DOOR)
NOTE : CARD INSERTS PROVIDED
HOLDER
AL CARD
BY USING AGENCY
FOAM TAPE
DOUBLE EMULSION
W/ SCREW
BACKING BOARD
ACRYLIC
ROOM IDENTIFICATION MISC IDENTIFICATION
100225
1C 2B
A1 A1
MECH ROOM
DOOR VIEWER
2B1C
A1 A1
1COMM/ELEC ROOM
1 PER EACH
VIEWER
R20
DOUBLE EMULSION
FOAM TAPE
3B3A REAR VIEWFRONT VIEW
ACRYLIC
CLEAR 2THK
ACRYLIC
WHITE 2THK
ACRYLIC
CLEAR 2THK
3C SECTION
R20
INSIDE ROOM
4 4
3D
FLEXI-INFO
EQ220EQ
ACRYLIC
WHITE 2MM THK
ACRYLIC
CLEAR 2MM THK
222 2
3 3
A1 A1
PLEXI-INFO HOLDER
BED RM DOOR
DOOR ELEVATION
COLOR IS TO
BACKGROUND
ROOF COLOR
7070 760
MATCH
S - 81
A15 A15 A15
A15A15A15
A15 A15
A15 A15
A15 A15
A15A15
A15
A15
A15 A15
A15
A15
DOOR
S-81
1 PER EACH BEDROOM
NOT TO SCALE
DETAILS @ BED RM
PLEXI-INFO HOLDER
YI, SC
185600
BUILDING S-81, CP CASEY
| 185600-Repair bldg S-81, Cp Casey-A-1 |
| 185600-Repair bldg S-81, Cp Casey-A-2 |
| 185600-Repair bldg S-81, Cp Casey-A-3 |
| 185600-Repair bldg S-81, Cp Casey-A-4 |
| 185600-Repair bldg S-81, Cp Casey-A-5 |
| 185600-Repair bldg S-81, Cp Casey-A-6 |
| 185600-Repair bldg S-81, Cp Casey-A-7 |
| 185600-Repair bldg S-81, Cp Casey-A-8 |
| 185600-Repair bldg S-81, Cp Casey-A-9 |
| 185600-Repair bldg S-81, Cp Casey-A-10 |
| 185600-Repair bldg S-81, Cp Casey-A-11 |
| 185600-Repair bldg S-81, Cp Casey-A-12 |
| 185600-Repair bldg S-81, Cp Casey-A-13 |
| 185600-Repair bldg S-81, Cp Casey-A-14 |
| 185600-Repair bldg S-81, Cp Casey-A-15 |
File details come from the government source that posted it.