This document contains an invitation for bid for an abatement and demolition project at Camp James A. Garfield in Ohio. The Ohio Army National Guard is seeking bids from Service Disabled Veteran Owned Small Businesses to perform asbestos abatement and demolition of Building U-0014 Cold Storage, with options to also demolish Buildings A0009, A0001, A001A, A0004, 0218, SD003, and 01026. Bids are due by September 8, 2022 at 1100 and will be publicly opened under the solar canopy at that time. A mandatory site visit will be held on August 19, 2022 at 1100 to tour each demolition location. All questions must be submitted in writing by August 23, 2022 at 1600. Bids must follow the specified format or risk being rejected.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Providing aggressive, cost effective solutions for today’s compliance needs
TMC Ltd. 145 Cheshire Road Hudson, OH 44236
330.998-1551 Phone mgradert@tmcconsulting.net Email
June 6, 2022
Nate Pietras Eurofins Environment Testing 4101 Shuffel St NW North Canton, OH 44720
RE: Asbestos Survey - Camp Ravenna
Dear Mr. Swift:
Please find enclosed the report for the asbestos survey conducted at Camp Ravenna located on 6499 George Rd in Ravenna, OH on May 31, 2022 by a representative of Tara Management Consulting, Ltd.
Eight (8) samples representing additional suspect materials for two structures identified by representative of the Ravenna Arsenal - Camp James A Garfield at 6499 George Road in Ravenna, Ohio were sampled by Mr. Daniel C. Peders (CAHES # 31134) on May 31, 2022.
After completing your review of the enclosed report, please contact me to further discuss the findings that have been developed as a result of this survey.
Sincerely, Mark Gradert
Mark A. Gradert, CIH, CSP Vice President mailto:mgradert@tmcconsulting.net
CERTIFICATE OF ANALYSIS
Client: Eurofins Report Date: June 2, 2022
4101 Shuffel St NW Project No.: 22-05-121
North Canton, Ohio 44720 Log No.: 3970
BULK SAMPLE ANALYSIS SUMMARY
Sample Identification:
Eight (8) samples representing additional suspect materials for two structures identified by representative of the Ravenna Arsenal - Camp James A Garfield at 6499 George Road in Ravenna, Ohio were sampled by Mr. Daniel
C. Peders (CAHES # 31134) on May 31, 2022. Sampling was performed in accordance with AHERA 763.86 sampling protocol. These bulk samples were delivered to Amianthus LLC Laboratory, Berea, Ohio for asbestos content determination
Analytical Method:
Analytical procedures were performed in accordance with the U. S. Environmental Protection Agency (EPA)
Recommended Method for the Determination of Asbestos in Bulk Samples by Polarized Light Microscopy and
Dispersion Staining (PLM/DS) (EPA-600/M4-82-020, EPA-600/R-93-116). This report relates only to those samples actually analyzed, and may not be indicative of other similar appearing materials existing at this, or other sites.
Quantification of asbestos content was determined by Calibrated Visual Estimation.
The EPA requires that friable samples with analytical results of 10% or less asbestos, by visual estimation, be treated as asbestos-containing material unless these quantities are verified using the point counting method. The point counting method is a systematic technique for estimating concentration, also using PLM. The point counting method, however, does not increase the analyst’s ability to detect fibers.
In any given material, fibers with a small diameter (<0.25µm) may not be detected by the PLM method. Floor tile and other resinously bound material may yield a false negative if the asbestos fibers are too small to be resolved using PLM. Additional analytical methods may be required.
Disclaimer: The results are based on the scope of sampling of suspect materials as identified by representative of the Ravenna Arsenal - Camp James A Garfield.
Analysis Performed By: Daniel C. Peders Approved By:
Date: June 2, 2022 Daniel C. Peders
Laboratory Director
AIHA PAT for Bulk Asbestos no. 198622 This confidential report relates only to those item(s) tested and does not represent an endorsement by AIHA or any agency of the U.S. Government
Analysis Method: EPA 600/R-93/116
Asbestos Type(s) Detected Non-Asbestos Materials 1 of 1
L ab
N o
Client No.
Description
Location
Color % C h ry so ti le
A m o si te ro ci d o li te
O th er el lu lo se
F ib ro u s
G la ss M in er al
W o o l
O th er
F ib ro u s
M at er ia ls
N o n -F ib ro u s
M at er ia ls
Comments
96437 RA-01 Black tar coating painted white
Building A1-A1-A, nailed onto wood ceiling joists in the room off the entrance that may have been cooler
Black/White 0 0 0 0 10 0 0 90
96438 RA-02 Black 0 0 0 0 10 0 0 90
96439 RA-03 Brown cork insulation, ~2” thick
Brown 0 0 0 0 0 0 0 100 Cork
96440 RA-04 Brown 0 0 0 0 0 0 0 100
96441 RA-05 Gray caulk Building A-9, South end on wall above small lower entrance section. May be residual from original roof.
Gray 0 0 0 0 0 0 0 100
96442 RA-06 Gray 0 0 0 0 0 0 0 100
96443 RA-07 Asphalt-based roof flashing
Black 0 0 0 0 25 20 0 55
96444 RA-08 Black 0 0 0 0 25 20 0 55
96445 RA-09 White caulk Building A-9, at seams of metal roof
White 0 0 0 0 0 0 0 100
96446 RA-10 White 0 0 0 0 0 0 0 100
AIHA PAT for Bulk Asbestos no. 198622 This confidential report relates only to those item(s) tested and does not represent an endorsement by AIHA or any agency of the U.S. Government
Analysis Method: EPA 600/R-93/116
Comments: PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Before this material can be considered or treated as non-asbestos containing, confirmation must be made by quantitative TEM. (PC) Indicates Stratified Point Count Performed. Method not performed unless stated. Quantification at <0.25% by volume is possible with this method. (PC-Trace) represents this limitation of quantitation. (PC-Trace) means that asbestos was detected but is not quantifiable under the Point Count regimen.
Date: _June 2, 2022 Daniel C. Peders
Laboratory Director
Report Date: 06/02/2022
Project: 22-05-121
Log No.: 3970
Analysis Performed By: _Daniel C. Peders Approved By:
Tara Management Consulting Ltd.
Ravenna Arsenal - Camp James A Garfield / 22-05-121 – May 31, 2022
Additional Suspect Materials Page 1 of 4
Daniel C. Peders, CAHES # 31134 Date Inspected: May 31, 2022
Photographic Log
Client Name:
Eurofins
Site Location:
Ravenna Arsenal - Camp James A Garfield
6499 George Rd., Ravenna, Ohio
Project No.
22-05-121
HSA No. Date:
TC1 & MM1 5-31-2022
Sample No’s.:
RA-01 & 02 (TC1) and
RA-03 & 04 (MM1)
Description:
Tar coating (TC1) over cork insulation (MM1)
Material Location:
Building A1-A1-A. Cork insulation is nailed onto wood ceiling joists in the room off the entrance that may have been cooler. The cork insulation is coated with a tar coating and painted white.
Additional Suspect Materials Page 2 of 4
Eurofins
Site Location:
Ravenna Arsenal - Camp James A Garfield
6499 George Rd., Ravenna, Ohio
Project No.
22-05-121
HSA No. Date:
CA1 & RF1 5-31-2022
RA-05 & 06 (CA1) and
RA-07 & 08 (RF1)
Description:
Gray caulk (CA1) and
Black roof flashing
(RF1)
Material Location:
Building A-9, South end on wall above small lower entrance section. May be residual from original roof.
Additional Suspect Materials Page 3 of 4
Eurofins
Site Location:
Ravenna Arsenal - Camp James A Garfield
6499 George Rd., Ravenna, Ohio
Project No.
22-05-121
HSA No.
CA2
Date:
5-31-2022
RA-09 & 10 (CA2)
Description:
White caulk (CA2)
Material Location:
Building A-9, at seams of metal roof
HSA No.
N/A
Not Suspect
Description:
Black rubber cover at flue pipes penetrating the metal roof. Also a black rubber strip at the leading edge of the roof.
Material Location:
Building A-9, at seams of metal roof
Additional Suspect Materials Page 4 of 4
Eurofins
Site Location:
Ravenna Arsenal - Camp James A Garfield
6499 George Rd., Ravenna, Ohio
Project No.
22-05-121
HSA No.
N/A
Not Suspect
Description:
White foam board insulation
Material Location:
Building A-9, under metal roof