Full_size_drawings_14.pdf
PDF 8 MB Posted
- Attached to
- Repair Maintenance Hangar, B102 Federal contract opportunity
- Solicitation number
- W9136419B7001
About this file
This notice is for a solicitation seeking bids for Project No. PBXP 132166 to repair and renovate the Maintenance Hangar, Building 102 at Mansfield Air National Guard Base in Mansfield, Ohio. Renovations include work on fire protection and suppression systems, mechanical, plumbing, electrical, and telecommunications, along with exterior brick veneer and metal siding replacement. Windows and doors will also be replaced to meet energy efficiency and antiterrorism force protection goals. The construction duration is 577 calendar days from notice to proceed, allowing time for demolition and construction work. Bids will be evaluated without discussions and award will be made to the responsible bidder whose bid conforms with all terms and conditions of the solicitation and is the lowest priced, technically acceptable offer. This project is set aside for small businesses with a NAICS code of 236220 and size standard of $36.5 million average annual revenue. The pre-bid conference is July 30, 2019 and bids are due August 23, 2019. Interested bidders must register in SAM and check the Federal Business Opportunities website for solicitation documents and any amendments.
Full size 14
View the file
Other files for this federal contract opportunity
Show all 50
Repair Maintenance Hangar, B102 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FILENAME: PLOT DATE: PLOT TIME:
C H
M H
IL
L
A
L L R
IG
H T S R
E S
E R
V E
D
C H
M H
IL
L A
N D I S N
O T T
O B
E U
S E
D
IN
W
H O
L E O
R I
N P
A R
T F
O R A
N Y O
T H
E R P
R O J E
C T W
IT
H
O U
T T
H E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N O
F C
H
M H
IL
L
T H
IS
D
O C
U M
E N
T
A N
D T
H E I
D E
A S A
N D D
E S
IG
N S I
N C
O R
P O
R A
T E
D H
E R
E
IN
A S A
N I
N S
T R
U M
E N
T O
F P
R O
F E
S S
IO
N A
L S
E R
V
IC
E
IS
T
H E P
R O
P E
R T
Y O
F R
E U
S E O
F D
O C
U M
E N
T S
1 2 3 4 5 6
B
C
D
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
1"0 c
PROJ
DATE
D A
T E
N O
D S
G N
D R
R E
V
IS
IO
N
C H
K
A P
V D
B Y
A P
V D
SHEET
DWG
A
R E
P A
IR
M
X H
A N
G A
R
M A
N S
F
IE
L D L
A H
M A
N G B
A S
E
A
IR
N
A T
IO
N A
L G
U A
R D
M A
N S
F
IE
L D
O H
IO
of pw://projectwise.ch2m.com:DEN001/Documents/669816&space;-&space;Repair&space;MX&space;Hangar/WIP/MX&space;Hangar&space;CAD/ME/Dlv/669816_M-506$PWURL
T
A Y
L O
R S
T R
E E
T S
U
IT
E
D A
Y T
O N
O H
IO
T E
L E (3
-0
F
A X (7
-9
C H
M H
IL
L H
D R J
V
M E
C H
A N
IC
A L
D E
T A
IL
S
M A
G L E
Y
FEB 2019
M
W
IL
S O
N M
D R
A G
O N
M-506
AS SHOWN
R P
E A
R S
O N
669816_M-506.dwg
669816
THROUGH INTERIOR WALL
NTS
CHILLED WATER PENETRATION
MECHANICAL PIPING HANGERS
STRUT
CLEVIS
WALL
ROOF
MATERIALS.
GALVANIZED OR STAINLESS STEEL
TO BUILDING SHALL BE EITHER
ALL SUPPORT ELEMENTS EXTERIOR C.
OF PIPING.
TO ALLOW FOR THERMAL MOVEMENT
SELECT LENGTH OF THREADED ROD B.
DISTANCES AND SIZES OF ELEMENTS.
REQUIREMENTS, INCLUDING SPACING
SEE 23 64 26 FOR ADDITIONAL A.
NOTES:
ARRANGEMENT SIMILAR
SHOWN; HORIZONTAL
WALL / VERTICAL STACK
WALL
A. TYPICAL FOR ALL HIGH POINTS, LOW POINTS AND POCKETS.
NOTES:
4" MIN
4" MIN
B. LOW POINT DRAINS SHALL BE 2" MINIMUM ON 6" AND LARGER MAINS.
MANUAL VENTS AND DRAINS
B. FOR PIPES 75MM AND LARGER, USE THRED-O-LET AS SHOWN.
A. FOR PIPING 50MM AND SMALLER, USE A BUSHING IN A TEE.
NOTES:
PRESSURE GAUGE
NTS
A.
B.
NOTES:
USE LINE INSTALLATION FOR SIZE 2-1/2" & LARGER.
USE TEE INSTALLATION FOR SIZE 2" & SMALLER.
THERMOMETER
OF WALL
OUTSIDE FACE
CHW PIPE
JACKET
PLATE
ESCUTCHEON
AND SEAL
WALL SLEEVE
INSULATION
CHILLED WATER PENETRATION
THE PUMPS ABILITY TO MOVE WITH PIPE EXPANSION MOVEMENT.
PUMP SUPPORTS SHALL NOT BE SO RIDIGDLY MOUNTED THAT IT LIMITS
A WAY AS TO NOT CREATE ANY STRESSES ON PUMP COMPONENTS.
BE PROVIDED . PUMP SUPPORTS MUST BE INSTALLED IN SUCH
WHERE REQ'D. AN ADDITIONAL PUMP SUPPORT BRACKET MAY
INLINE PUMP
VERTICAL
W/ COMP. FITTINGS
1/4" O.D. COPPER TUBING
PRESSURE INDICATOR
COMPOUND TYPE
TO SYSTEM
ISOLATION VALVE (TYP)
W/ 3/4" NPT COPPER WELL
9" INDUSTRIAL THERMOMETER
DRAIN: TERMINATE NEAR F.D.
(INCREASER/DECREASER WHERE REQ'D.)
STAINLESS STEEL BRAIDED CONNECTOR
BLOWDOWN VALVE / DRAIN
STRAINER (LINE SIZE) W/ HOSE ENDED
Trerice
& NEOPRENE TYPE)
PIPE HANGERS (SPRING
FROM SYSTEM
RECOMMENDED INSTALLATION INSTRUCTIONS.
INLINE PUMP PER THE MANUFACTURER'S
INSTALLING AND SUPPORTING THE VERTICAL
INSTALLER IS RESPONSIBLE FOR
VERTICAL INLINE PUMP DETAIL - (PIPING MOUNTED)
NTS
MANUAL VENT
1" MIN DRAIN
RETURN MAIN
SUPPLY OR
1/2" MIN IPS
PRESSURE GAUGE
LIQUID FILLED DIAL
1/4" x 1/2" SNUBBER
SEE NOTES A AND B
1/2" BALL VALVE
TYPICAL.
ESCUTCHEONS,
PIPE
CHILLED WATER
(CONCRETE OR CMU)
INTERIOR WALL
PIPE INSULATION
SAFEING.
FIREPROOFING AND
PACKAGED MINERAL WOOL
THROUGH SLEEVE.
CENTER PIPE
WATER PIPE
LARGER THAN CHILLED
STEEL PIPE SLEEVE, 2"
THROUGH EXTERIOR WALL
NTS
THERMOMETER THERMOMETER
& LARGER TEES
3/4" BUSHING ON 1" STEM
STEM
WELL
WELL
3/4" THRED-O-LET
LARGER
PIPES 2-1/2" &
OUTLET
& SMALLER
PIPES 2"
INLET
ACCOMMODATE MOVEMENT.
NUT. LENGTH AS NEEDED TO
THRU-BOLTED WITH DOUBLE
THREADED ROD,
CLEVIS
MOVEMENT (TYP)
NEEDED TO ACCOMMODATE
DOUBLE NUT. LENGTH AS
THRU-BOLTED WITH
THREADED ROD,
CLEVIS (TYP)
3/4" STRUT
PIPE / TUBING
STRUT CLAMP FOR
PRE-INSULATED
BRACKET
GALVANIZED STEEL WALL
MSS TYPE 32 PURCHASED
WALL.
OR SLEEVE ANCHOR INTO CMU
CELL OF CMU WALL (TYP)
FLOOR, COLUMN, OR GROUTED
SOLID CONCRETE WALL,
EXPANSION ANCHOR INTO
CMU WALL (TYP)
OR GROUTED CELL OF
WALL, FLOOR, COLUMN,
INTO SOLID CONCRETE
EXPANSION ANCHOR
YARD
CLAMP AT MECHANICAL
IN BUILDING OR BEAM
USING CONCRETE ANCHOR
TO STRUCTURE ABOVE
CONNECT THREADED ROD
MSS TYPE 1
ADJUSTABLE CLEVIS,
BARRIER CONTINUOUS
INSULATION & VAPOR
SHIELD MSS TYPE 40
INSULATION PROTECTION
OR CONDENSATE PIPE
MECHANICAL CHILLED WATER
CONDENSATE PIPE
CHILLED WATER OR
MECHANICAL
ROOF SURFACE
PAVERS ON
ROOF SURFACE
PAVERS ON
AND DESIGN, HOUSTON, TX
PSE-2-2 FROM PHP SYSTEMS
FRAMING SIMILAR TO MODEL
PURCHASED SUPPORT RACK
PRE-ENGINEERED,
BARRIER CONTINUOUS (TYP)
INSULATION & VAPOR
PAVERS
SURFACE OF ROOF
DIRECTLY ON TOP
SET SUPPORT PLATES
(TYP)
CONDENSATE PIPE
CHILLED WATER OR
MECHANICAL
BALANCE VALVE
CALIBRATED
CHECK VALVE
(NOT SHOWN)
NOTE: INSULATE PUMP BODY
199 B D
E S
IG
N S
U B
M
IT
T A
L
-0
-1
IS
S U
E D F
O R C
O N
S T
R U
C T
IO
N D
P
P
H
M H
IL
L
A
L L R
IG
H T S R
E S
E R
V E
D
C H
M H
IL
L A
N D I S N
O T T
O B
E U
S E
D
IN
W
H O
L E O
R I
N P
A R
T F
O R A
N Y O
T H
E R P
R O J E
C T W
IT
H
O U
T T
H E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N O
F C
H
M H
IL
L
T H
IS
D
O C
U M
E N
T
A N
D T
H E I
D E
A S A
N D D
E S
IG
N S I
N C
O R
P O
R A
T E
D H
E R
E
IN
A S A
N I
N S
T R
U M
E N
T O
F P
R O
F E
S S
IO
N A
L S
E R
V
IC
E
IS
T
H E P
R O
P E
R T
Y O
F R
E U
S E O
F D
O C
U M
E N
T S
1 2 3 4 5 6
B
C
D
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
1"0 c
PROJ
DATE
D A
T E
N O
D S
G N
D R
R E
V
IS
IO
N
C H
K
A P
V D
B Y
A P
V D
SHEET
DWG
A
R E
P A
IR
M
X H
A N
G A
R
M A
N S
F
IE
L D L
A H
M A
N G B
A S
E
A
IR
N
A T
IO
N A
L G
U A
R D
M A
N S
F
IE
L D
O H
IO
of pw://projectwise.ch2m.com:DEN001/Documents/669816&space;-&space;Repair&space;MX&space;Hangar/WIP/MX&space;Hangar&space;CAD/ME/Dlv/669816_M-601$PWURL
T
A Y
L O
R S
T R
E E
T S
U
IT
E
D A
Y T
O N
O H
IO
T E
L E (3
-0
F
A X (7
-9
C H
M H
IL
L H
D R J
V
M E
C H
A N
IC
H E
D U
L E
S
S H
E E
T O
F
D
M A
G L E
Y
FEB 2019
M
W
IL
S O
N M
D R
A G
O N
M-601
AS SHOWN
B D
E S
IG
N S
U B
M
IT
T A
L
D R P
E A
R S
O
669816_M-601.dwg
NO.
EQUIP.
UNIT
OUTDOOR
ASSOC.
DESCRIPTION
& MODEL NUMBER
MANUFACTURER
BASIS OF DESIGN
SERVICE
COOLING LOAD HEATING LOAD
REF.
CFM
AIRFLOW
MEDIAN ELECTRICAL DATA
LBS
UNIT WT.
REMARKS/ ACCESSORIES
BTU/H
TOTAL
°F
AMBIENT TEMP
BTU/H
TOTAL
°F
AMBIENT TEMP
V/PH/HZ MCA MOCP
FCU-14A HP-14 CEILING CASSETTE CARRIER - 40MBQB18C--3 ELECTRICAL129 18,000 90.5 18,000 6.7 R-410A 350 NOTE 6 NOTE 6 NOTE 6 39.7 1,2,3,4,5
FCU-14B HP-14 CEILING CASSETTE CARRIER - 40MBQB09C--3 FIRE EQUIPMENT 128 9,000 90.5 9,000 6.7 R-410A 320 NOTE 6 NOTE 6 NOTE 6 35.3 1,2,3,4,5
FCU-14C HP-14 CEILING CASSETTE CARRIER - 40MBQB09C--3 FIRE EQUIPMENT 128 9,000 90.5 9,000 6.7 R-410A 320 NOTE 6 NOTE 6 NOTE 6 35.3 1,2,3,4,5
DUCTLESS SPLIT SYSTEM OUTDOOR HEAT PUMP UNIT SCHEDULE
NO.
EQUIP.
DESCRIPTION
& MODEL NUMBER
MANUFACTURER
BASIS OF DESIGN
SERVICE LOCATION
COOLING LOAD HEATING LOAD
REF.
ELECTRICAL DATA
LBS
UNIT WT.
REMARKS/ ACCESSORIES
BTU/H
TOTAL
°F
AMBIENT TEMP
SEER
EFFICIENCY
BTU/H
TOTAL
°F
AMBIENT TEMP
HSPF
EFFICIENCY
V/PH/HZ MCA MOCP
HP-14 OUTDOOR HEAT PUMP CARRIER - 38MGQF36--3 FCU-14A, -14B, -14C AT GRADE 36,000 90.5 20.5 36,000 6.7 10 R-410A 208/1/60 27 40 170 1, 2, 3
REMARKS/ ACCESSORIES:
1. CAPACITIES BASED ON STANDARD AHRI CONDITIONS
2. INTEGRAL CONDENSATE LIFT PUMP
3. MECHANICAL CONTRACTOR SHALL PROVIDE ELECTRICAL DISCONNECT
4. INDIVIDUAL WALL MOUNTED REMOTE THERMOSTAT
5. MINIMUM 3 SUPPLY AIRFLOW RATES/FAN SPEEDS
6. UNIT WIRED TO OUTDOOR UNIT FOR POWER
REMARKS/ ACCESSORIES:
1. UNIT MOUNTED DISCONNECT SWITCH
2. INVERTER DRIVEN VARIABLE SPEED COMPRESSOR
3. SINGLE ZONE UNIT4. MULTI-ZONE UNIT
DEDICATED OUTSIDE AIR UNIT SCHEDULE
NO.
EQUIP.
DESCRIPTION
& MODEL NUMBER
MANUFACTURER
BASIS OF DESIGN
SERVICE LOCATION
CFM
AIR
OUTSIDE
CFM
AIR
EXHAUST
SUPPLY AIR FAN EXHAUST AIR FAN** ENERGY RECOVERY WHEEL
CFM
AIRFLOW
IN. W.G.
ESP/TSP*
TYPE
MOTOR
CFM
AIRFLOW
IN. W.G.
ESP/TSP*
TYPE
MOTOR SUMMER CONDITIONS OA WINTER CONDITIONS
(MIN)
EFFECTIVENESS
HP DRIVE VFD HP DRIVE VFD
EA EAT OA EAT OA LAT EA EAT OA EAT OA LAT SUMMER / WINTER
DB F WB F DB F WB F DB F WB F DB F DB F DB F SENS. LAT.
DOAS-1
AIR UNIT, OUTDOORS
DEDICATED OUTSIDE
RN-006-3-0-EA09-329
AAON
ADMINISTRATION
SOUTH
LOW ROOF 875 705 875 1.25/2.24 CENT. 1 DIRECT YES 705 0.75/1.25 CENT. 1.0 DIRECT YES 78 65 85.5 71.8 81.35 66.76 68 6.7 50.99 50% 50%
DEDICATED OUTSIDE AIR UNIT SCHEDULE (CONT.)
COOLING MODE DATA HEATING MODE DATA HOT GAS REHEAT PRE-FILTER DATA FINAL FILTER COMPRESSOR DATA ELECTRICAL DATA
LBS
WEIGHT
ACCESSORIES
REMARKS/
TOTAL EAT LAT
(MIN)
DESIGN
EER
MBH
HGRH
DEG F
EAT
DEG F
LAT
MBH
HEATING
REQ.
TOTAL
MBH
OUTPUT
HEATING
MBH
INPUT
HEATING
TYPE
HEATING
MBH
CAPACITY
TOTAL
LAT
TYPE
EFF.
VEL. FPM
FACE
MAX
TYPE
EFF.
VEL. FPM
FACE
MAX
QTY RLA EA. FLA MCA MOCP V/PH/HZ
MBH
EQUIVALENT
MBH
GROSS
DB F WB F DB F WB F
DEG F
DB
DEG F
WB
66.97 51.25 81.4 66.8 48.1 46.2 13.0 18.0 51 76.4 60.9 71.9 90
GAS
NATURAL
MODULATING
23 70.0 55.7 2" PLEAT
(MERV 8)
30%
500 4" PLEAT MERV 13 375 1 8.1 15 17 25.0 460/3/60 1,500 1 - 13
* ESP = EXTERNAL PRESSURE LOSS IS EXTERNAL OF UNIT AND DOES NOT INCLUDE ANY INTERNAL LOSSES SUCH AS DIRTY FILTERS, HEAT WHEELS, ETC. TSP = MINIMUM TOTAL STATIC PRESSURE
** EXHAUST FAN AND UNIT SHALL OPERATE AT MINIMUM AIRFLOW INDICATED AND SHALL BE CAPABLE OF MAXIMUM AIRFLOW EQUAL TO SUPPLY AIRFLOW
REMARKS/ ACCESSORIES:
1. PACKAGE OUTDOOR DX UNIT WITH COMPRESSOR, COOLING COIL, MODULATING NATURAL GAS HEAT, SUPPLY FAN, EXHAUST FAN, AIR-COOLED CONDENSER, ENERGY RECOVERY WHEEL, FILTERS, ETC.
2. DOUBLE WALL CASING WITH 2-INCH INSULATION
3. INTERNAL FAN VIBRATION ISOLATORS AND UNIT FLEXIBLE DUCT CONNECTORS
4. PREMIUM EFFICIENCY MOTORS RATED FOR INVERTER DUTY
5. SUPPLY AND EXHAUST FAN VARIABLE FREQUENCY DRIVE
6. EXHAUST AND OUTSIDE AIR LOW LEAKAGE DAMPERS WITH ACTUATORS
7. HINGED ACCESS DOORS WITH DOUBLE WALL INSULATION
8. R-410A REFRIGERANT
9. NON-FUSED ELECTRICAL DISCONNECT
10. GFCI OUTLET
11. DIGITAL SCROLL COMPRESSOR
12. REMOTE CONTROL PANEL WITH LCD TOUCHSCREEN AND BACNET INTERFACE FOR INTEGRATION WITH FACILITY BAS
13. 24" HIGH INSULATED ROOF CURB
DUCTLESS SPLIT SYSTEM INDOOR FAN COIL UNIT SCHEDULE
-0
-1
IS
S U
E D F
O R C
O N
S T
R U
C T
IO
N D
P
H
M H
IL
L
A
L L R
IG
H T S R
E S
E R
V E
D
C H
M H
IL
L A
N D I S N
O T T
O B
E U
S E
D
IN
W
H O
L E O
R I
N P
A R
T F
O R A
N Y O
T H
E R P
R O J E
C T W
IT
H
O U
T T
H E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N O
F C
H
M H
IL
L
T H
IS
D
O C
U M
E N
T
A N
D T
H E I
D E
A S A
N D D
E S
IG
N S I
N C
O R
P O
R A
T E
D H
E R
E
IN
A S A
N I
N S
T R
U M
E N
T O
F P
R O
F E
S S
IO
N A
L S
E R
V
IC
E
IS
T
H E P
R O
P E
R T
Y O
F R
E U
S E O
F D
O C
U M
E N
T S
1 2 3 4 5 6
B
C
D
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
1"0 c
PROJ
DATE
D A
T E
N O
D S
G N
D R
R E
V
IS
IO
N
C H
K
A P
V D
B Y
A P
V D
SHEET
DWG
A
R E
P A
IR
M
X H
A N
G A
R
M A
N S
F
IE
L D L
A H
M A
N G B
A S
E
A
IR
N
A T
IO
N A
L G
U A
R D
M A
N S
F
IE
L D
O H
IO
of pw://projectwise.ch2m.com:DEN001/Documents/669816&space;-&space;Repair&space;MX&space;Hangar/WIP/MX&space;Hangar&space;CAD/ME/Dlv/669816_M-602$PWURL
T
A Y
L O
R S
T R
E E
T S
U
IT
E
D A
Y T
O N
O H
IO
T E
L E (3
-0
F
A X (7
-9
C H
M H
IL
L H
D R J
V
M E
C H
A N
IC
H E
D U
L E
S
S H
E E
T O
F
D
M A
G L E
Y
FEB 2019
A M
E A
D O
W S
J C
O E
N
M-602
AS SHOWN
B D
E S
IG
N S
U B
M
IT
T A
L
D R P
E A
R S
O
669816_M-602.dwg
VARIABLE REFRIGERANT VOLUME SYSTEM INDOOR UNIT SCHEDULE
NO.
EQUIP.
DESCRIPTION
& MODEL NUMBER
MANUFACTURER
BASIS OF DESIGN
SERVICE
LOAD
COOLING
LOAD
HEATING
REF.
CFM
AIRFLOW
ELECTRICAL DATA
LBS
UNIT WT.
REMARKS/ ACCESSORIES
BTU/H
TOTAL
BTU/H
TOTAL
V/PH/HZ MCA MOCP
FCU-01
DUCTED
CEILING CONCEALED
MITSUBISHI - PEFY-P12NMAU-E3 ISO/DOCK SHOP 11,600 12,500 R-410A 350 208/1/60 1.20 15 44 1,2,3,4,5,6
FCU-02
1-WAY
CEILING CASSETTE
MITSUBISHI - PMFY-P06NBMU-ER5 STENCIL SHOP 5,780 6,200 R-410A 300 208/1/60 0.25 15 40 1,2,3,4,5,6
FCU-03
DUCTED
CEILING CONCEALED
MITSUBISHI - PEFY-P06NMAU-E3
ENTRY LOBBY 114
MULT-PURPOSE 125
5,780 6,200 R-410A 310 208/1/60 1.20 15 44 1,2,3,4,5,6
FCU-04
1-WAY
CEILING CASSETTE
MITSUBISHI - PMFY-P06NBMU-ER5 OFFICE 126 5,780 6,200 R-410A 300 208/1/60 0.25 15 40 1,2,3,4,5,6
FCU-05
1-WAY
CEILING CASSETTE
MITSUBISHI - PMFY-P06NBMU-ER5 CORRIDOR 111 5,780 6,200 R-410A 300 208/1/60 0.25 15 40 1,2,3,4,5,6
FCU-06 WALL MOUNTED MITSUBISHI - PKFY-P06NBMU-E2
LOCKER
WOMENS RESTROOM &
5,780 6,200 R-410A 200 208/1/60 0.19 15 30 1,2,3,4,5,6
FCU-07A WALL MOUNTED MITSUBISHI - PKFY-P06NBMU-E2
LOCKER
MENS RESTROOM &
5,780 6,200 R-410A 200 208/1/60 0.19 15 30 1,2,3,4,5,6
FCU-07B WALL MOUNTED MITSUBISHI - PKFY-P06NBMU-E2
LOCKER
MENS RESTROOM &
5,780 6,200 R-410A 200 208/1/60 0.19 15 30 1,2,3,4,5,6
FCU-08
4-WAY
CEILING CASSETTE
MITSUBISHI - PLFY-P12NCMU-ER4
ROOM 205
MEETING/CONF
11,500 12,500 R-410A 390 208/1/60 0.35 15 50 1,2,3,4,5,6
FCU-09
4-WAY
CEILING CASSETTE
MITSUBISHI - PLFY-P15NCMU-ER4
TRAINING/BREAK ROOM
14,200 15,600 R-410A 390 208/1/60 0.35 15 50 1,2,3,4,5,6
FCU-10
4-WAY
CEILING CASSETTE
MITSUBISHI - PLFY-P15NCMU-ER4
TRAINING/BREAK ROOM
14,200 15,600 R-410A 390 208/1/60 0.35 15 50 1,2,3,4,5,6
FCU-11
4-WAY
CEILING CASSETTE
MITSUBISHI - PLFY-P08NCMU-ER4 TRAINING ROOM 202 7,600 8,200 R-410A 350 208/1/60 0.29 15 50 1,2,3,4,5,6
FCU-12
DUCTED
CEILING CONCEALED
MITSUBISHI - PEFY-P06NMAU-E3
OFFICE 204
SENIOR OFFICE 203
5,780 6,200 R-410A 310 208/1/60 1.20 15 44 1,2,3,4,5,6
FCU-13A
1-WAY
CEILING CASSETTE
MITSUBISHI - PMFY-P06NBMU-ER5 CORRIDOR 207 5,780 6,200 R-410A 300 208/1/60 0.25 15 40 1,2,3,4,5,6
FCU-13B
1-WAY
CEILING CASSETTE
MITSUBISHI - PMFY-P06NBMU-ER5 CORRIDOR 207 5,780 6,200 R-410A 300 208/1/60 0.25 15 40 1,2,3,4,5,6
6. MINIMUM 3 FAN SPEEDS
5. MECHANICAL CONTRACTOR SHALL PROVIDE ELECTRICAL DISCONNECT
4. WALL MOUNTED THERMOSTAT/CONTROLLER
3. INTEGRAL CONDENSATE LIFT PUMP
2. HEATING CAPACITIES BASED ON 68F ENTERING AIR CONDITION
1. COOLING CAPACITIES BASED ON 78F/50% ENTERING AIR CONDITION
REMARKS/ ACCESSORIES:
VARIABLE REFRIGERANT FLOW SYSTEM OUTDOOR UNIT SCHEDULE
NO.
EQUIP.
DESCRIPTION
& MODEL NUMBER
MANUFACTURER
BASIS OF DESIGN
SERVICE LOCATION
COOLING LOAD HEATING LOAD
REF.
ELECTRICAL DATA
LBS
UNIT WT.
REMARKS/ ACCESSORIES
BTU/H
TOTAL
°F
AMBIENT TEMP
EER
EFFICIENCY
BTU/H
TOTAL
°F
AMBIENT TEMP
COP
EFFICIENCY
V/PH/HZ
(NOTE 2)
MCA
(NOTE 2)
MOCP
HP-1 OUTDOOR HEAT PUMP MITSUBISHI - PURY-HP144TSKMU-A-H ADMIN SPACE LOW ROOFTOP 128,000 90.5 13 138,800 6.7 3.4 R-410A 208/3/60 44/44 60/60 1100 1,2,3
3. TWINNING KIT TO COMBINE 2 MODULES INTO ONE UNIT
2. ELECTRICAL DATA IS FOR EACH MODULE OF THE COMBINED UNIT
1. UNIT MOUNTED DISCONNECT SWITCH(S)
REMARKS/ ACCESSORIES:
-0
-1
IS
S U
E D F
O R C
O N
S T
R U
C T
IO
N D
P
H
M H
IL
L
A
L L R
IG
H T S R
E S
E R
V E
D
C H
M H
IL
L A
N D I S N
O T T
O B
E U
S E
D
IN
W
H O
L E O
R I
N P
A R
T F
O R A
N Y O
T H
E R P
R O J E
C T W
IT
H
O U
T T
H E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N O
F C
H
M H
IL
L
T H
IS
D
O C
U M
E N
T
A N
D T
H E I
D E
A S A
N D D
E S
IG
N S I
N C
O R
P O
R A
T E
D H
E R
E
IN
A S A
N I
N S
T R
U M
E N
T O
F P
R O
F E
S S
IO
N A
L S
E R
V
IC
E
IS
T
H E P
R O
P E
R T
Y O
F R
E U
S E O
F D
O C
U M
E N
T S
1 2 3 4 5 6
B
C
D
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
1"0 c
PROJ
DATE
D A
T E
N O
D S
G N
D R
R E
V
IS
IO
N
C H
K
A P
V D
B Y
A P
V D
SHEET
DWG
A
R E
P A
IR
M
X H
A N
G A
R
M A
N S
F
IE
L D L
A H
M A
N G B
A S
E
A
IR
N
A T
IO
N A
L G
U A
R D
M A
N S
F
IE
L D
O H
IO
of pw://projectwise.ch2m.com:DEN001/Documents/669816&space;-&space;Repair&space;MX&space;Hangar/WIP/MX&space;Hangar&space;CAD/ME/Dlv/669816_M-603$PWURL
T
A Y
L O
R S
T R
E E
T S
U
IT
E
D A
Y T
O N
O H
IO
T E
L E (3
-0
F
A X (7
-9
C H
M H
IL
L H
D R J
V
M E
C H
A N
IC
H E
D U
L E
S
S H
E E
T O
F
D
M A
G L E
Y
FEB 2019
M
W
IL
S O
N M
D R
A G
O N
M-603
AS SHOWN
B D
E S
IG
N S
U B
M
IT
T A
L
D R P
E A
R S
O
669816_M-603.dwg
PACKAGE ROOFTOP UNIT SCHEDULE
NO.
EQUIP.
DESCRIPTION
& MODEL NUMBER
MANUFACTURER
BASIS OF DESIGN
SERVICE LOCATION
CFM
OUTSIDE AIR
DESIGN
SUPPLY FAN DATA EXHAUST FAN DATA
CFM
AIRFLOW
IN. WG *
EXT. S.P.
TYPE
RPM
FAN MOTOR
CFM
AIRFLOW
IN. WG
EXT. S.P.
TYPE
RPM
FAN MOTOR
HP DRIVE VFD V/PH/HZ HP DRIVE VFD V/PH/HZ
RTU-1 PACKAGED ROOFTOP
RN-007-3-0-EA09-329
AAON
WHEEL & TIRE SHOP LOW ROOF 590 2,340 1.25 CENTRIF 1703 2 DIRECT YES 480/3/60 2,000 0.75 CENTRIF 1019 2 DIRECT YES 480/3/60
RTU-2 PACKAGED ROOFTOP
RN-008-3-0-EA09-3K9
AAON
HYDRO SHOP LOW ROOF 690 2,730 1.25 CENTRIF 1840 3 DIRECT YES 480/3/60 2,280 0.75 CENTRIF 1090 2 DIRECT YES 480/3/60
RTU-3 PACKAGED ROOFTOP
RQ-003-3-V-EA09-319
AAON
LOX/E&E SHOP LOW ROOF 350 1,220 1.25 CENTRIF 1810 2 DIRECT YES 480/3/60 870 0.75 CENTRIF 1505 1 DIRECT YES 480/3/60
RTU-4 PACKAGED ROOFTOP
RN-009-3-0-EB08-3F9
AAON
METAL SHOP
STRUCTURAL SHEET
LOW ROOF 1,060 3,580 1.25 CENTRIF 1765 3 DIRECT YES 480/3/60 3,000 0.75 CENTRIF 940 2 DIRECT YES 480/3/60
PACKAGE ROOFTOP UNIT SCHEDULE (CONT.)
DX COOLING COIL DATA HEATING - NATUAL GAS CONDENSING UNIT DATA PRE- FILTER DATA FINAL FILTER DATA ELECTRICAL DATA
LBS
UNIT WT.
ACCESSORIES
REMARKS /
CFM
MBH
TOTAL
REFRIG.
MBH
SENS EAT LAT (UNIT)
IN.WG
P.D.
MAX. AIR
VEL. FPM
FACE
MAX.
STAGES
MBH
CAPACITY
MBH
INPUT
PSIG
MAX.
TEMP. F
AMBIENT
DESIGN
TEMP. F
AMBIENT
MIN. COMPRESSOR(S) CONDENSER FAN(S)
TYPE
EFF.
TYPE
EFF.
FLA MCA MOCP V/PH/HZ
DB F WB F DB F WB F QTY RLA EA. STAGES QTY HP EA
2,340 68.5 R-410A 50.6 80.6 67.5 60.1 58.0 0.75 500 MODULATING 120 150 0.5 90.5 10 1 10 VFD 1 1/3 2" PLEAT 30 4" PLEAT MERV 13 19.0 22.0 30.0 480/3/60 1,280 1-19
2,730 88.9 R-410A 62.2 80.3 67.2 58.7 56.4 0.75 500 MODULATING 120 150 0.5 90.5 10 1 13 VFD 1 3/4 2" PLEAT 30 4" PLEAT MERV 13 23.0 26.0 35.0 480/3/60 1,330 1-19
1,220 38.6 R-410A 27.2 80.6 67.6 58.5 57.2 0.75 500 MODULATING 48.6 60 0.5 90.5 10 1 13 VFD 1 1/3 2" PLEAT 30 4" PLEAT MERV 13 14.0 16.0 20.0 480/3/60 950 1-18
3,580 104.5 R-410A 81.6 80.7 67.4 59.1 57.9 0.75 500 MODULATING 156 195 0.5 90.5 10 2 7.8 / 6.2 VFD 2 1/3 2" PLEAT 30 4" PLEAT MERV 13 28.0 30.0 35.0 480/3/60 2,000 1-19
* EXTERNAL STATIC PRESSURE INCLUDES DIRTY FILTER PRESSURE LOSS.
REMARKS/ ACCESSORIES:
1. DOUBLE WALL CASING WITH 2" INSULATION
2. INTERNAL FAN VIBRATION ISOLATORS
3. PREMIUM EFFICIENCY FAN MOTORS
4. SUPPLY AND EXHAUST VARIABLE FREQUENCY DRIVES
5. LIGHTING AND GFCI RECEPTACLE, 120V CIRCUIT WITH JUNCTION BOX
6. ENTHALPY CONTROLLED ECONOMIZER W/POWERED EXHAUST
7. PREFABRICTED INSULATED ROOF CURB (MATCH SLOPE OF ROOF); 24" HIGH
8. DRAW-THRU ARRANGEMENT
9. GAS TRAIN CONTROLS, PRESSURE REGULATOR, SHUT-OFF VALVE, ETC.
10. STAINLESS STEEL GAS BURNER HEAT EXCHANGER
11. HOT GAS BYPASS
12. DDC CONTROLLER WITH BACNET INTERFACE
13. CO2 MONITORING/OVERRIDE FOR DEMAND CONTROL VENTILATION
14. OUTSIDE AIRFLOW MONITORING
15. INTERNAL NON-FUSED DISCONNECT (LOCKABLE)
16. VARIABLE SPEED COMPRESSOR
17. SINGLE POINT ELECTRICAL CONNECTION
18. REMOTE MONITOR/ CONTROL PANEL
19. DUCT SMOKE DETECTOR
8. GFI SERVICE RECEPTICAL
7. SUPPLY AIR SMOKE DETECTOR
6. HORIZONTAL DISCHARGE
5. INTAKE AIR WEATHER HOOD
4. DDC MICROPROCESSOR CONTROLS WITH BACNET INTERFACE
3. 80/20 RECIRCULATION/OUTSIDE AIR VENTILATION OPTION
2. VARIABLE FREQUENCY DRIVE
1. PREMIUM EFFICIENT MOTOR
EXTERNAL PRESSURE LOSS INCLUDES DIRTY FILTER PRESSURE LOSS.*
MAKE UP AIR UNIT SCHEDULE
EQUIP. NO. LOCATION SERVICE
& MODEL NUMBER
MANUFACTURER
BASIS OF DESIGN
CFM
OUTSIDE AIR
MINIMUM
F
AIR TEMP.
OUTSIDE
FAN DATA NATURAL GAS FIRED FURNACE DATA FILTER DATA
LBS
WEIGHT
REMARKS/ ACCESSORIES
CFM
AIRFLOW
IN. WC *
EXT. S.P.
TYPE RPM
MOTOR
TURNDOWN
MODULATING
TYPE
MBH
HEATING
MBH
INPUT
PSIG
MAX
TYPE
EFF.
IN. WC
INIT. P.D.
HP DRIVE VFD V/PH/HZ
MAU-1 LOW ROOF HANGAR
DGX-P125-H32
GREENHECK
10875 6.7 10875 1.5
PLENUM
CENTRIF.
1660 10 DIRECT YES 460/3/60 30:1
FIRED
DIRECT
736 800 0.5 PLEATED MERV 8 0.128 1,603 1,2,3,4,5,6,7,8
-0
-1
IS
S U
E D F
O R C
O N
S T
R U
C T
IO
N D
P
H
M H
IL
L
A
L L R
IG
H T S R
E S
E R
V E
D
C H
M H
IL
L A
N D I S N
O T T
O B
E U
S E
D
IN
W
H O
L E O
R I
N P
A R
T F
O R A
N Y O
T H
E R P
R O J E
C T W
IT
H
O U
T T
H E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N O
F C
H
M H
IL
L
T H
IS
D
O C
U M
E N
T
A N
D T
H E I
D E
A S A
N D D
E S
IG
N S I
N C
O R
P O
R A
T E
D H
E R
E
IN
A S A
N I
N S
T R
U M
E N
T O
F P
R O
F E
S S
IO
N A
L S
E R
V
IC
E
IS
T
H E P
R O
P E
R T
Y O
F R
E U
S E O
F D
O C
U M
E N
T S
1 2 3 4 5 6
B
C
D
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
1"0 c
PROJ
DATE
D A
T E
N O
D S
G N
D R
R E
V
IS
IO
N
C H
K
A P
V D
B Y
A P
V D
SHEET
DWG
A
R E
P A
IR
M
X H
A N
G A
R
M A
N S
F
IE
L D L
A H
M A
N G B
A S
E
A
IR
N
A T
IO
N A
L G
U A
R D
M A
N S
F
IE
L D
O H
IO
of pw://projectwise.ch2m.com:DEN001/Documents/669816&space;-&space;Repair&space;MX&space;Hangar/WIP/MX&space;Hangar&space;CAD/ME/Dlv/669816_M-604$PWURL
T
A Y
L O
R S
T R
E E
T S
U
IT
E
D A
Y T
O N
O H
IO
T E
L E (3
-0
F
A X (7
-9
C H
M H
IL
L H
D R J
V
M E
C H
A N
IC
H E
D U
L E
S
S H
E E
T O
F
D
M A
G L E
Y
FEB 2019
M
W
IL
S O
N M
D R
A G
O N
M-604
AS SHOWN
B D
E S
IG
N S
U B
M
IT
T A
L
D R P
E A
R S
O
669816_M-604.dwg
FAN SCHEDULE
NO
EQUIP.
DESCRIPTION
& MODEL NUMBER
MANUFACTURER
BASIS OF DESIGN
SERVICE LOCATION
CFM
AIRFLOW
TOTAL
IN. WG
EXT. S.P.
RPM
FAN
MOTOR
LBS
WEIGHT
REMARKS/ ACCESSORIES
HP DRIVE
TYPE
MOTOR
VFD V/PH/HZ
EF-1
UPBLAST EXHAUST
TUBULAR CENTRIFUGAL
TCBRU-1-10
GREENHECK
WHEEL & TIRE SHOP LOW ROOF 590 0.25 1,199 1/4 BELT ODP NO 120/1/60 200 1,2,3,4,7,10,11
EF-2
UPBLAST EXHAUST
TUBULAR CENTRIFUGAL
TCBRU-1-10
GREENHECK
HYDRO SHOP LOW ROOF 690 0.25 1,320 1/4 BELT ODP NO 120/1/60 200 1,2,3,4,7,10,11
EF-3
EXHAUST
CENTRIFUGAL UPBLAST
CUE-090-VG
GREENHECK
LOX/E&E SHOP LOW ROOF 350 0.25 1,109 1/10 DIRECT TENV NO 120/1/60 40 1,4,7,10,11
EF-4
UPBLAST EXHAUST
TUBULAR CENTRIFUGAL
TCBRU-1-10
GREENHECK
METAL SHOP
STRUCTURAL SHEET
LOW ROOF 890 0.25 1,581 1/4 BELT ODP NO 120/1/60 200 1,2,3,4,7,10,11
EF-5
EXHAUST
CENTRIFUGAL UPBLAST
CUE-070-VG
GREENHECK
DOCK CKT LOW ROOF 175 0.25 1,364 1/10 DIRECT TENV NO 120/1/60 30 1,4,7,10,11
EF-6 INLINE TUBE AXIAL
TBI-FS-3L42
GREENHECK
HANGAR EXHAUST HANGAR BAY 20,000 0.25 758 3 BELT TEFC YES 460/3/60 600 1,2,3,5,6,7,8,9,11,12
EF-7 INLINE TUBE AXIAL
TBI-FS-3L42
GREENHECK
HANGAR EXHAUST HANGAR BAY 20,000 0.25 758 3 BELT TEFC YES 460/3/60 600 1,2,3,5,6,7,8,9,11,12
SF-1
ROOF SUPPLY
TUBULAR CENTRIFUGAL
TCBRS-1-12
GREENHECK
ISO CAGE STORAGE LOW ROOF 800 0.38 1,160 1/4 BELT ODP NO 120/1/60 300 1,2,3,4,7,11,14
TF-1 CENTRIFUGAL CABINET FAN
CSP-A700
GREENHECK
ADMINISTRATION CORRIDOR 111 460 0.38 796 3.2 A DIRECT ODP NO 120.1/60 40 1,5,9,13,15,16
16, RUBBER IN SHEAR HANGING VIBRATION ISOLATORS
15, ELECTRICAL DISCONNECT
14. INTAKE HOOD
13. MOTOR SPEED CONTROL FOR BALANCING
12. INVERTER DUTY MOTOR FOR VFD OPERATION
11. NEMA 4 DISCONNECT
10. DISCHARGE WIND BAND
9. INLET AND OUTLET FLEX DUCT CONNECTOR
8. SPRING VIBRATION ISOLATORS
7. ACCESS PANEL FOR INTERNAL COMPONENT MAINTENANCE
6. MOUNTING RAILS
5. INLET AND DISCHARGE FLANGES
4. 24" HIGH ROOF CURB
3. BELT GUARD
2. MOTOR GUARD
1. PREMIUM EFFICIENT MOTOR
REMARKS/ ACCESSORIES:
UNIT HEATER SCHEDULE
NO.
EQUIP.
DESCRIPTION
& MODEL NUMBER
MANUFACTURER
BASIS OF DESIGN
SERVICE
MBH
HEATING
AIR TEMP. FAN DATA GAS DATA
LBS.
UNIT WT.
REMARKS/ ACCESSORIES
F
EAT
F
LAT
CFM
AIRFLOW
HP V/PH/HZ
BTU/HR
INPUT
IN. W.C.
MAX.
BTU/HR
OUTPUT
STAGES
GAS
TYPE OF
UH-1
GAS, GRAVITY VENT
HIGH EFF., PROPELLER FAN,
REZNOR F50 MECH ROOM 130 40.0 55 112 650 1/35 115/1/60 50 7 40 1 NATURAL 79 1, 2, 3, 4
UH-2
GAS, GRAVITY VENT
HIGH EFF., PROPELLER FAN,
REZNOR F25 ISO CAGE STORAGE 127 20.0 55 105 380 1/50 115/1/60 25 7 20 1 NATURAL 72 1, 2, 3, 4
4. ANSI Z83.8 CERTIFIED
3. 24V CONTROL TRANSFORMER
2. 30 DEG., ADJUSTABLE HORIZONTAL DISCHARGE LOUVER
1. COMBINATION GAS LINE PRESSURE REGULATOR/VALVE
REMARKS/ ACCESSORIES:
5. WALL MOUNTED SPEED CONTROL POTENTIOMETER; ONE TO CONTROL DF-9 THRU 14
4. WALL MOUNTED SPEED CONTROL POTENTIOMETER; ONE TO CONTROL DF-1 THRU -8
3. OFF WHITE FINISH
2. 6-FT STEEL SAFETY CABLE
1. PREMIUM EFFICIENT MOTOR
REMARKS/ ACCESSORIES:
DESTRATIFICATION FAN SCHEDULE
EQUIP. DESCRIPTION BASIS OF DESIGN SERVICE/LOCATION MAX
RPM
FAN
MOTOR
Db(A)
SOUND
WEIGHT
FT
HEIGHT
MAX
COVERAGE REMARKS/ ACCESSORIES
WATT DRIVE
TYPE
MOTOR
V/PH/HZ
DF-1 THRU DF-8 JET DESTRATIFICATION FAN
AIR PEAR 45-EC-STD
AIRIUS
HANGAR BAY 1,290 3,050 175 DIRECT EC 208/1/60 71 15 45 1500 1,2,3,4
DF-9 THRU DF-14 JET DESTRATIFICATION FAN
AIR PEAR 45-EC-STD
AIRIUS
HANGAR BAY 1,290 3,050 175 DIRECT EC 208/1/60 71 15 45 1500 1,2,3,5
-0
-1
IS
S U
E D F
O R C
O N
S T
R U
C T
IO
N D
P
H
M H
IL
L
A
L L R
IG
H T S R
E S
E R
V E
D
C H
M H
IL
L A
N D I S N
O T T
O B
E U
S E
D
IN
W
H O
L E O
R I
N P
A R
T F
O R A
N Y O
T H
E R P
R O J E
C T W
IT
H
O U
T T
H E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N O
F C
H
M H
IL
L
T H
IS
D
O C
U M
E N
T
A N
D T
H E I
D E
A S A
N D D
E S
IG
N S I
N C
O R
P O
R A
T E
D H
E R
E
IN
A S A
N I
N S
T R
U M
E N
T O
F P
R O
F E
S S
IO
N A
L S
E R
V
IC
E
IS
T
H E P
R O
P E
R T
Y O
F R
E U
S E O
F D
O C
U M
E N
T S
1 2 3 4 5 6
B
C
D
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
1"0 c
PROJ
DATE
D A
T E
N O
D S
G N
D R
R E
V
IS
IO
N
C H
K
A P
V D
B Y
A P
V D
SHEET
DWG
A
R E
P A
IR
M
X H
A N
G A
R
M A
N S
F
IE
L D L
A H
M A
N G B
A S
E
A
IR
N
A T
IO
N A
L G
U A
R D
M A
N S
F
IE
L D
O H
IO
of pw://projectwise.ch2m.com:DEN001/Documents/669816&space;-&space;Repair&space;MX&space;Hangar/WIP/MX&space;Hangar&space;CAD/ME/Dlv/669816_M-605$PWURL
T
A Y
L O
R S
T R
E E
T S
U
IT
E
D A
Y T
O N
O H
IO
T E
L E (3
-0
F
A X (7
-9
C H
M H
IL
L H
D R J
V
M E
C H
A N
IC
H E
D U
L E
S
S H
E E
T O
F
D
M A
G L E
Y
FEB 2019
M
W
IL
S O
N M
D R
A G
O N
M-605
AS SHOWN
B D
E S
IG
N S
U B
M
IT
T A
L
D R P
E A
R S
O
669816_M-605.dwg
AIR DEVICE SCHEDULE
NO.
TAG
DESCRIPTION TYPE
INCH
SIZE
NECK
INCH
SIZE
FACE
LEVEL
NC
MAX.
ACCESSORIES
REMARKS/
CD-1 SUPPLY DIFFUSER
T-BAR CEILING
LOUVER FACE, LAY-IN,
6 24x24 25 3, 4
CD-2 SUPPLY DIFFUSER
MOUNT
LOUVER FACE, SURFACE
8 24x24 25 3, 4
CD-3 SUPPLY DIFFUSER
MOUNT
LOUVER FACE, SURFACE
12 24x24 25 3, 4
CR-1 CEILING RETURN
T-BAR CEILING
1/2"x1/2", EGGCRATE, LAY-IN 8x8 24x24 25 3,4
CR-2 CEILING RETURN
T-BAR CEILING
1/2"x1/2", EGGCRATE, LAY-IN 10x10 24x24 25 3,4
CR-3 CEILING RETURN
T-BAR CEILING
1/2"x1/2", EGGCRATE, LAY-IN 12x12 24x24 25 3,4
RG-1
GRILLE
RETURN/EXHAUST
SPACING, 35° DEFLECTION
PARALLEL BLADE, 3/4"
18x10 20x12 25 1, 3, 4
RG-2
GRILLE
RETURN/EXHAUST
SPACING, 35° DEFLECTION
PARALLEL BLADE, 3/4"
24x10 26x12 25 1, 3, 4
RG-3
GRILLE
RETURN/EXHAUST
SPACING, 35° DEFLECTION
PARALLEL BLADE, 3/4"
18x6 20x8 25 1, 3, 4
RG-4
GRILLE
RETURN/EXHAUST
SPACING, 35° DEFLECTION
PARALLEL BLADE, 3/4"
12x8 14x10 25 1, 3, 4
RG-5
GRILLE
RETURN/EXHAUST
SPACING, 35° DEFLECTION
PARALLEL BLADE, 3/4"
12x6 14x8 25 1, 3, 4
SG-1 SUPPLY GRILLE
DEFLECTION, 3/4" SPACING,
PARALLEL BLADE, DOUBLE
12x8 14x10 25 1, 3, 4
SG-2 SUPPLY GRILLE
SPACING, 35° DEFLECTION
PARALLEL BLADE, 3/4"
12x6 14x8 25 1, 3, 4
SG-3 SUPPLY GRILLE
SPACING, 35° DEFLECTION
PARALLEL BLADE, 3/4"
10x6 12x8 25 1, 3, 4
SG-4 SUPPLY GRILLE
SPACING, 35° DEFLECTION
PARALLEL BLADE, 3/4"
6x6 8x8 25 1, 3, 4
EG-1 EXHAUST GRILLE
T-BAR CEILING
1/2"x1/2", EGGCRATE, LAY-IN, 6x6 8x8 30 1, 2, 4
EG-2 EXHAUST GRILLE
T-BAR CEILING
1/2"x1/2", EGGCRATE, LAY-IN, 8x8 10x10 30 1, 2, 4
EG-3 EXHAUST GRILLE
MOUNT
1/2"x1/2", EGGCRATE, SURFACE 8x6 10x8 30 1, 2, 4
EG-4 EXHAUST GRILLE
MOUNT
1/2"x1/2", EGGCRATE, SURFACE 6x6 8x8 30 1, 2, 4
4. WHITE FINISH
3. STEEL CONSTRUCTION
2. ALUMINUM CONSTRUCTION
1. OPPOSED BLADE DAMPERS
REMARKS/ ACCESSORIES:
3. MOTORIZED ACTUATOR
2. COLOR FINISH PER OWNER STANDARD
1. BIRD SCREEN
REMARKS/ ACCESSORIES:
LOUVER & DAMPER SCHEDULE
SYMBOL DESCRIPTION
& MODEL NUMBER
MANUFACTURER
SERVICE AREA
IN.
WIDTH
IN.
HEIGHT
FT²
AREA
FREE
CFM
FLOW
AIR
FPM
VELOCITY
MAX.
IN. W.G.
DROP
PRESS.
ACCESSORIES
REMARKS/
L-1
LOUVER, DRAINABLE BLADE
6 IN. DEEP, STATIONARY
RUSKIN L6375D HANGAR 84 42 13 7500 600 0.03 1, 2
L-2
LOUVER, DRAINABLE BLADE
6 IN. DEEP, STATIONARY
RUSKIN L6375D HANGAR 84 42 13 7500 600 0.03 1, 2
L-3
LOUVER, DRAINABLE BLADE
6 IN. DEEP, STATIONARY
RUSKIN L6375D HANGAR 84 42 13 7500 600 0.03 1, 2
L-4
LOUVER, DRAINABLE BLADE
6 IN. DEEP, STATIONARY
RUSKIN L6375D HANGAR 84 42 13 7500 600 0.03 1, 2
L-5
LOUVER, DRAINABLE BLADE
6 IN. DEEP, COMBINATION
RUSKIN LC6375D MECH RM 60 24 3.67 1100 300 0.02 1,2,3
4. LOUVERED GRILLE
3. 24-V CONTROL TRANSFORMER
2. SURFACE MOUNTING CABINET ENCLOSURE
1.BUILT-IN THERMOSTAT CONTROL
REMARKS/ ACCESSORIES:
ELECTRIC UNIT HEATER SCHEDULE
SYMBOL DESCRIPTION
& MODEL NUMBER
MANUFACTURER
BASIS OF DESIGN
LOCATION
BTUH
HEATING
V/PH/HZ
ELECTRIC DATA
LBS
UNIT WT.
REMARKS/ ACCESSORIES
EUH-1
UNIT HEATER
WALL MOUNTED ELECTRIC
QMARK CWH110DSF VESTIBULE (101) 3410 / 1705 120/1/60 1 / 0.5 2 55 1, 2, 3, 4
EUH-2
EUH-3
KW
STAGES
NO.
UNIT HEATER
WALL MOUNTED ELECTRIC
QMARK CWH110DSF STAIR #1 (111) 3410 / 1705 120/1/60 1 / 0.5 2 55 1, 2, 3, 4
UNIT HEATER
WALL MOUNTED ELECTRIC
QMARK CWH110DSF STAIR #2 (133) 3410 / 1705 120/1/60 1 / 0.5 2 55 1, 2, 3, 4
-0
-1
IS
S U
E D F
O R C
O N
S T
R U
C T
IO
N D
P
H
M H
IL
L
A
L L R
IG
H T S R
E S
E R
V E
D
C H
M H
IL
L A
N D I S N
O T T
O B
E U
S E
D
IN
W
H O
L E O
R I
N P
A R
T F
O R A
N Y O
T H
E R P
R O J E
C T W
IT
H
O U
T T
H E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N O
F C
H
M H
IL
L
T H
IS
D
O C
U M
E N
T
A N
D T
H E I
D E
A S A
N D D
E S
IG
N S I
N C
O R
P O
R A
T E
D H
E R
E
IN
A S A
N I
N S
T R
U M
E N
T O
F P
R O
F E
S S
IO
N A
L S
E R
V
IC
E
IS
T
H E P
R O
P E
R T
Y O
F R
E U
S E O
F D
O C
U M
E N
T S
1 2 3 4 5 6
B
C
D
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
1"0 c
PROJ
DATE
D A
T E
N O
D S
G N
D R
R E
V
IS
IO
N
C H
K
A P
V D
B Y
A P
V D
SHEET
DWG
A
R E
P A
IR
M
X H
A N
G A
R
M A
N S
F
IE
L D L
A H
M A
N G B
A S
E
A
IR
N
A T
IO
N A
L G
U A
R D
M A
N S
F
IE
L D
O H
IO
of pw://projectwise.ch2m.com:DEN001/Documents/669816&space;-&space;Repair&space;MX&space;Hangar/WIP/MX&space;Hangar&space;CAD/ME/Dlv/669816_M-610$PWURL
T
A Y
L O
R S
T R
E E
T S
U
IT
E
D A
Y T
O N
O H
IO
T E
L E (3
-0
F
A X (7
-9
C H
M H
IL
L H
D R J
V
M E
C H
A N
IC
D
IC
A T
E D O
U T S
ID
E A
IR
S
Y S
T E
M
(D O
A S
C O
N T
R O
L D
IA
G R
A M
D
M A
G L E
Y
FEB 2019
M
W
IL
S O
N M
D R
A G
O N
M-610
AS SHOWN
B D
E S
IG
N S
U B
M
IT
T A
L
D R P
E A
R S
O
669816_M-610.dwg
M
M
E N
E R
G Y R
E C
O V
E R
Y H
E A
T W
H E
E L
D X C
O
IL
P R
E -F
IL
T E
R
SF-1
EF-1
SA
RA
OA
EA
CLOSEST TO ITS HEATING SETPOINT.
DETERMINE THE CRITICAL SPACE AS THE ZONE WITH A TEMPERATURE
CONTROLLER FOR THE FCU'S IN THE VRF SYSTEM; THE BAS SHALL
BY MONITORING THE SPACE TEMPERATURES MEASURED BY EACH ZONE
SHALL BE DETERMINED AS FOLLOWS: SAT 70°F (ADJ) AT SPACE
REQUIRED SUPPLY AIR TEMPERATURE. THE SUPPLY AIR TEMPERATURE
THE DOAS SHALL OPERATE UNDER ITS OWN CONTROLS TO PROVIDE THE
EXHAUST FAN AIR FLOW MONITORING STATIONS, AFM-01 AND AFM-02.
AIR FLOW RATE SHALL BER MONITORED BY MEANS OF THE SUPPLY AND
CONTROLLER OR BAS TO PROVIDE THE DESIGN AIR FLOW AS SCHEDULED;
SUPPLY AND EXHAUST FAN SPEED IS MANUALLY SET THROUGH THE
GRAVITY DAMPER.
SUPPLY AND EXHAUST FANS START. EXHAUST AIR DAMPER SHALL BE A
RA DAMPER (AAD-02) SHALL OPEN, ENTHALPY WHEEL ENABLE, AND THE
ON A SIGNAL TO START FROM THE DDC SYSTEM, OA DAMPER (AAD-01) AND
BUILDING IS SCHEDULED TO BE OCCUPIED.
THE DOAS SHALL BE SCHEDULED TO RUN CONTINUOUSLY WHENEVER THE
PROTECTION.
FACTORY CONTROLS SHALL INCLUDE ENTHALPY WHEEL FROST
DEHUMIDIFICATION AND HEATING OF OUTSIDE AIR TO THE BUILDING.
PROVIDED WITH FACTORY DDC CONTROLS TO PROVIDE COOLING,
POINTS SHALL BE ADJUSTABLE THROUGH THE BAS. THE DOAS SHALL BE
THE BAS SHALL MONITOR AND START/STOP THE DOAS UNITS ONLY. SET
SETTINGS SHALL BE ADJUSTABLE (ADJ)):
THE DOAS SHALL OPERATE AS FOLLOWS (ALL SUGGESTED SET POINTS AND
INTERFACE)
(BACNET
TO BAS
F
IL
T E
R
COMP
H O
T G
A S R
E H
E A
T
COND
(RCS)
CONTROL PANEL
DOAS REMOTEF
IN
A L F
IL
T E
R
DAMPER
GRAVITY
F U
R N
A C
E
N A
T U
R A
L G
SHALL SIGNAL A FAN FAILURE.
OF THE FAN AS DETERMINED BY A CURRENT SWITCH (SCS-01)
CONTINUOUSLY WHENEVER DOAS-1 IS OPERATING. A FAILURE
SYSTEM AND RUN SUBJECT TO ITS SAFETIES. FAN SHALL RUN
THE FAN SHALL BE STARTED AND STOPPED FROM THE DDC
TRANSFER FAN (TF-1)
SEQUENCE OF OPERATION
SS
M
TRANSFER FAN (TF-1) CONTROL DIAGRAM
SCALE = NONE
DEVICE & POINT LISTING (TF-1)
ID TYPE DESCRIPTION REMARKS PROVISION
SS-01 DO DDC CONTRACTOR
(ADJUSTABLE)
SETPOINT
(ADJUSTABLE)
ALARM POINT
TRANSFER FAN START/STOP- -
INTAKE
AIR
DISCHARGE
AIR
SCS
DEVICE & POINT LISTING (DOAS-1)
ID TYPE DESCRIPTION REMARKS PROVISION
AFM-01 AI WITH DOAS
(ADJUSTABLE)
SETPOINT
(ADJUSTABLE)
ALARM POINT
MEASUREMENT
SUPPLY AIR FLOW
AS SCHEDULED -
AND FA506 FOR DETAILS.
ALARM SHEETS FA113 FOR LOCATION
LOCATED IN THE MNS LOC; SEE FIRE 1.
NOTES:
DEDICATED OUTSIDE AIR SYSTEM (DOAS-1) CONTROL DIAGRAM
SCALE = NONE
DEDICATED OUTSIDE AIR SYSTEM (DOAS-1)
SEQUENCE OF OPERATION
AFM-02 AI WITH DOAS
MEASUREMENT
EXHAUST AIR FLOW
AS SCHEDULED -
RH-01 AI WITH DOASOUTSIDE AIR HUMIDITY- -
RH-02 AI WITH DOAS
FIRST FLOOR
SPACE RELATIVE HUMIDITY - -
TS-01 AI WITH DOASSUPPLY AIR TEMPERATURE- -
TS-02 AI WITH DOASOUTSIDE AIR TEMPERATURE- -
TS-03 AI WITH DOAS
TEMPERATURE
HEAT WHEEL LEAVING AIR - -
TS-04 AI WITH DOAS
TEMPERATURE
DX COIL LEAVING AIR - -
VFD-01 WITH DOAS
SPEED
SUPPLY FAN MOTOR VARIABLE
DI WITH DOASENTHALPY WHEEL STATUS- -
STATUS, DI-ALARM
AO-SPEED, DO-START, DI-RUN
VFD-02 WITH DOAS
SPEED
EXHAUST FAN MOTOR VARIABLE
STATUS, DI-ALARM
AO-SPEED, DO-START, DI-RUN
DO AS SCHEDULED - POWERED THROUGH DOAS WITH DOAS
AIR DAMPER
DAMPER ACTUATOR - OUTSIDE
AAD-01
DO AS SCHEDULED - POWERED THROUGH DOAS WITH DOAS
AIR DAMPER
DAMPER ACTUATOR - RETURN
AAD-02
DPS-01 DI - > 0.1" WG WITH DOAS
SENSOR
DIFFERENTIAL PRESSURE
OUTSIDE AIR PRE-FILTER
AND CENTRAL COMPUTER UPON ALARM
FILTER" STATUS TO DDC CONTROLLER
DIRTY FILTER ALARM TO SEND "CHANGE
DPS-02 WITH DOAS
DI WITH DOASDOAS STATUS / ALARM- -
ES-01 DI DDC CONTRACTOR
DISTRIBUTION SHUT-OFF
BUILDING EMERGENCY AIR - - NOTE 1
DI WITH DOASFURNACE STATUS- -
RH
ES
CONTROLS
MOUNTED
SPACE
FIRST FLOOR
BUILDING
COMMON FOR
SECOND FLOOR
TS
AFM
VFD
DPS
AAD
AFM
RH-03 AI WITH DOAS
SECOND FLOOR
SPACE RELATIVE HUMIDITY - -
TS-05 AI WITH DOASEXHAUST AIR TEMPERATURE- -
GENERAL NOTES
OR NOT EXPLICITLY STATED.
TIME DELAYS, ETC. SHALL BE ADJUSTABLE, WHETHER
ALL SET POINTS, THRESHOLD VALUES, ALARM LIMITS, B.
AND NOTES.
SEE DRAWING M-001 FOR SYMBOLS, ABBREVIATIONS A.
ACTIVATION.
SHUT-DOWN AND DAMPERS MUST CLOSE WITHIN 30 SECONDS OF
ACTIVATED, A STOP COMMAND WILL BE ISSUED. ALL EQUIPMENT MUST
AIR DISTRIBUTION SHUT-OFF (ES-01) LOCATED INSIDE THE BUILDING IS
BUILDING EMERGENCY AIR DISTRIBUTION SHUT-OFF: IF THE EMERGENCY
AND MAINTAINED IN MEMORY FOR A PERIOD OF 12 MONTHS (ADJ.)
INPUTS FROM ALL CONTROL POINTS. LOG SHALL BE UPDATED HOURLY (ADJ.)
TRENDING AND STATUS LOG: DDC SHALL MAINTAIN LOG OF SETPOINTS AND
FAILURE, SUPPLY/EXHAUST DIRTY FILTER ALARM, DOAS COMMON ALARM.
TEMPERATURE ALARM, ENTHALPY WHEEL FAULT, SUPPLY/EXHAUST FAN
THE DDC SHALL BE NOTIFIED OF THE FOLLOWING ALARMS: LOW DISCHARGE
(AAD-02) DAMPERS SHALL CLOSE.
IF THE DOAS SHUTS DOWN FOR ANY REASON, THE OA (AAD-01) AND RA
MAINTAIN THE SUPPLY AIR TEMPERATURE SET POINT.
HEATING: GAS-FIRED FURNACE IS ENABLED AND MODULATES CAPACITY TO
MODULATE TO MAINTAIN SUPPLY AIR TEMPERATURE SET POINT.
CAPACITY WILL MODULATE TO MAINTAIN THE COIL LEAVING AIR
AND/OR RH-03, AND THE SPACE DEWPOINT IS ABOVE 45°F. COOLING COIL
SPACE RELATIVE HUMIDITY EXCEEDS 60% (ADJ) AS DETERMINED BY RH-02
DEHUMIDIFICATION: UNIT SHALL GO INTO DEHUMIDIFICATION MODE IF THE
CAPACITY TO MAINTAIN SUPPLY AIR TEMPERATURE SET POINT.
COOLING: DIGITAL SCROLL COMPRESSOR IS ENABLED AND MODULATES
SCS-01 DI DDC CONTRACTORCURRENT SWITCH- - VERIFY FAN ON/OFF STATUS
DPS-03 DI - > 0.1" WG WITH DOAS
SENSOR
DIFFERENTIAL PRESSURE
EXHAUST AIR FILTER
AND CENTRAL COMPUTER UPON ALARM
FILTER" STATUS TO DDC CONTROLLER
DIRTY FILTER ALARM TO SEND "CHANGE
DI - > 0.1" WG
SENSOR
DIFFERENTIAL PRESSURE
OUTSIDE AIR FINAL FILTER
AND CENTRAL COMPUTER UPON ALARM
FILTER" STATUS TO DDC CONTROLLER
DIRTY FILTER ALARM TO SEND "CHANGE
TS-06 AI - - RETURN AIR TEMPERATURE WITH DOAS
-0
-1
IS
S U
E D F
O R C
O N
S T
R U
C T
IO
N D
P
H
M H
IL
L
A
L L R
IG
H T S R
E S
E R
V E
D
C H
M H
IL
L A
N D I S N
O T T
O B
E U
S E
D
IN
W
H O
L E O
R I
N P
A R
T F
O R A
N Y O
T H
E R P
R O J E
C T W
IT
H
O U
T T
H E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N O
F C
H
M H
IL
L
T H
IS
D
O C
U M
E N
T
A N
D T
H E I
D E
A S A
N D D
E S
IG
N S I
N C
O R
P O
R A
T E
D H
E R
E
IN
A S A
N I
N S
T R
U M
E N
T O
F P
R O
F E
S S
IO
N A
L S
E R
V
IC
E
IS
T
H E P
R O
P E
R T
Y O
F R
E U
S E O
F D
O C
U M
E N
T S
1 2 3 4 5 6
B
C
D
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
1"0 c
PROJ
DATE
D A
T E
N O
D S
G N
D R
R E
V
IS
IO
N
C H
K
A P
V D
B Y
A P
V D
SHEET
DWG
A
R E
P A
IR
M
X H
A N
G A
R
M A
N S
F
IE
L D L
A H
M A
N G B
A S
E
A
IR
N
A T
IO
N A
L G
U A
R D
M A
N S
F
IE
L D
O H
IO
of pw://projectwise.ch2m.com:DEN001/Documents/669816&space;-&space;Repair&space;MX&space;Hangar/WIP/MX&space;Hangar&space;CAD/ME/Dlv/669816_M-611$PWURL
T
A Y
L O
R S
T R
E E
T S
U
IT
E
D A
Y T
O N
O H
IO
T E
L E (3
-0
F
A X (7
-9
C H
M H
IL
L H
D R J
V
M E
C H
A N
IC
K E -U
P A
IR
U
N
IT
(M A
U
C O
N T
R O
L D
IA
G R
A M
D
M A
G L E
Y
FEB 2019
M
W
IL
S O
N M
D R
A G
O N
M-611
AS SHOWN
B D
E S
IG
N S
U B
M
IT
T A
L
D R P
E A
R S
O
669816_M-611.dwg
SHUT-OFF (ES-01) LOCATED INSIDE THE BUILDING IS ACTIVATED, A STOP COMMAND WILL BE ISSUED.
IF THE EMERGENCY AIR DISTRIBUTION BUILDING EMERGENCY AIR DISTRIBUTION SHUT-OFF:
INITIAL A SMOKE ALARM IF SMOKE IS DETECTED.
SMOKE DETECTOR LOCATED IN SUPPLY AIR STREAM (DSD-01) SHALL ISSUE A "STOP" COMMAND AND
SMOKE DETECTION:
ADJUSTABLE) BASED ON A DUCT TEMPERATURE SENSOR (TS-01).
HEATING; THE GAS FURNACE WILL LIGHT AT FULL FIRE (100%) AFTER BURNER IS LIT. DDC
BASED ON OUTSIDE AIR TEMPERATURE SENSOR (TS-02) THE DDC SYSTEM SHALL CALL FOR
MODULATING GAS HEAT:
SHALL ISSUE A STOP COMMAND AND SIGNAL A FAN FAILURE.
SUPPLY FAN AS DETERMINED BY A DIFFERENTIAL PRESSURE SWITCH (DPS-01) ACROSS THE FAN
FAN SHALL OPERATE CONTINUOUSLY DURING OCCUPIED MODE. A FAILURE OF THE SUPPLY FAN:
SHALL CLOSE, NATURAL GAS FURNACE SHALL DE-ENERGIZE AND SIGNAL AN "OFF" CONDITION.
ON COMMAND TO STOP THE SUPPLY FAN SHALL DE-ENERGIZE, THE OUTSIDE AIR DAMPER STOP:
ALSO CONTROL THE MODULATING NATURAL GAS FURNACE, AND SIGNAL AN "ON" CONDITION.
OUTSIDE AIR DAMPER END SWITCH SIGNALS THAT THE DAMPER IS OPEN. DDC CONTROLLER SHALL
NORMAL OPERATING POSITION (DESIGN AIR SETTING). SUPPLY FAN WILL ENERGIZE ONCE THE
START: ON A COMMAND TO START THE OUTSIDE AIR DAMPER (AAD-01) OF MAU SHALL OPEN TO
ITS SAFETIES.
STARTED AND STOPPED FROM THE DDC CONTROLLER OR HOST COMPUTER AND RUN SUBJECT TO
DDC CONTROLLER OR HOST COMPUTER THROUGH THE LONWORKS INTERFACE. MAU SHALL BE
THE MAU SHALL BE INDEXED FOR OCCUPIED/UNOCCUPIED MODE THROUGH THE MANUFACTURER
100% OUTSIDE AIR MAU
SEQUENCE OF OPERATION
GENERAL NOTES
OR NOT EXPLICITLY STATED.
TIME DELAYS, ETC. SHALL BE ADJUSTABLE, WHETHER
ALL SET POINTS, THRESHOLD VALUES, ALARM LIMITS, B.
AND NOTES.
SEE DRAWING M-001 FOR SYMBOLS, ABBREVIATIONS A.
SAOA
SCALE = NONE
ID TYPE DESCRIPTION REMARKS PROVISION
AO AS SCHEDULED - WITH MAU
DPS-01 DI - WITH MAU>0.1" WG VERIFY FAN ON/OFF STATUS
VFD-01
(ADJUSTABLE)
SETPOINT
(ADJUSTABLE)
ALARM POINT
SUPPLY FAN MOTOR
VARIABLE SPEED DRIVE
PRESSURE SENSOR
AIR FILTER DIFFERENTIAL AIR
AIR DAMPER
DAMPER ACTUATOR - OUTSIDE
AAD-01
STATUS, DI-ALARM
AO-SPEED, DO-START, DI-RUN
WITH MAU
F U
R N
A C
E
G
T U
R
TS-01 AI WITH MAU
SUPPLY AIR
TEMPERATURE SENSORSETPOINT
TS-02 AI WITH MAU
OUTSIDE AIR
TEMPERATURE SENSOR
VFD FOR BALANCING
CONSTANT VOLUME UNIT
DSD-01 DI WITH MAU
SUPPLY AIR
SMOKE DETECTOR
DETECTION
SMOKE
FREEZE PROTECTION
SET POINT AND ALARM POINT FOR
38°F 35°F
MOUNTED
SPACE
ES-01 DI DDC CONTRACTOR
DISTRIBUTION SHUT-OFF
BUILDING EMERGENCY AIR - -
INTEGRAL TO MAU
BOUNDARY OF EQUIPMENT
BUILDING
COMMON FOR
LOCATED IN THE MNS LOC; SEE FIRE ALARM SHEETS FA113 FOR LOCATION AND FA506 FOR DETAILS.1.
NOTES:
NOTE 1
F
IL
T E
R
DSD
PROVIDED WITH MAU; FIELD INSTALLED
DPS-02 DI - WITH MAU-
SENSOR SUPPLY AIR FAN
DIFFERENTIAL AIR PRESSURE
CENTRAL COMPUTER UPON ALARM
FILTER" STATUS TO DDC CONTROLLER AND
DIRTY FILTER ALARM TO SEND "CHANGE
-0
-1
IS
S U
E D F
O R C
O N
S T
R U
C T
IO
N D
P
H
M H
IL
L
A
L L R
IG
H T S R
E S
E R
V E
D
C H
M H
IL
L A
N D I S N
O T T
O B
E U
S E
D
IN
W
H O
L E O
R I
N P
A R
T F
O R A
N Y O
T H
E R P
R O J E
C T W
IT
H
O U
T T
H E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N O
F C
H
M H
IL
L
T H
IS
D
O C
U M
E N
T
A N
D T
H E I
D E
A S A
N D D
E S
IG
N S I
N C
O R
P O
R A
T E
D H
E R
E
IN
A S A
N I
N S
T R
U M
E N
T O
F P
R O
F E
S S
IO
N A
L S
E R
V
IC
E
IS
T
H E P
R O
P E
R T
Y O
F R
E U
S E O
F D
O C
U M
E N
T S
1 2 3 4 5 6
B
C
D
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
1"0 c
PROJ
DATE
D A
T E
N O
D S
G N
D R
R E
V
IS
IO
N
C H
K
A P
V D
B Y
A P
V D
SHEET
DWG
A
R E
P A
IR
M
X H
A N
G A
R
M A
N S
F
IE
L D L
A H
M A
N G B
A S
E
A
IR
N
A T
IO
N A
L G
U A
R D
M A
N S
F
IE
L D
O H
IO
of pw://projectwise.ch2m.com:DEN001/Documents/669816&space;-&space;Repair&space;MX&space;Hangar/WIP/MX&space;Hangar&space;CAD/ME/Dlv/669816_M-612$PWURL
T
A Y
L O
R S
T R
E E
T S
U
IT
E
D A
Y T
O N
O H
IO
T E
L E (3
-0
F
A X (7
-9
C H
M H
IL
L H
D R J
V
M E
C H
A N
IC
C K
A G
E D R
O O
F T
O P U
N
IT
(R T
U
C O
N T
R O
L D
IA
G R
A M
D
M A
G L E
Y
FEB 2019
M
W
IL
S O
N M
D R
A G
O N
M-612
AS SHOWN
B D
E S
IG
N S
U B
M
IT
T A
L
D R P
E A
R S
O
669816_M-612.dwg
DEVICE & POINT LISTING - PACKAGE DX ROOFTOP UNIT (RTU-1, -2, -3 & -4)
ID* TYPE DESCRIPTION REMARKS PROVISION
DO AS SCHEDULED - POWERED THROUGH RTU WITH RTU
DPS-01 DI - > 0.1" WG WITH RTU
DPS-02 DI - - VERIFY FAN ON/OFF STATUS WITH RTU
(ADJUSTABLE)
SETPOINT
(ADJUSTABLE)
ALARM POINT
SENSOR SUPPLY AIR FAN
DIFFERENTIAL AIR PRESSURE
PRESSURE SENSOR
AIR FILTER DIFFERENTIAL AIR
AIR DAMPER
DAMPER ACTUATOR - OUTSIDE
AND CENTRAL COMPUTER UPON ALARM
FILTER" STATUS TO DDC CONTROLLER
DIRTY FILTER ALARM TO SEND "CHANGE
MODULATE THE FURNACE INPUT RATE TO MATCH THE LOAD.
TEMPERATURE BASED ON TEMPERATURE SENSOR/TRANSMITTER (TS-01) AND
(100%). AFTER BURNER IS LIT, DDC CONTROLLER SHALL MONITOR THE SPACE
UPON RECEIVING A CALL FOR HEAT, THE GAS FURNACE WILL LIGHT AT FULL FIRE
:MODULATING GAS HEAT
TEMPERATURE REQUIRED TO MAINTAIN SPACE CONDITIONS.
CAPACITY, HOT GAS REHEAT WILL MODULATE TO MAINTAIN SUPPLY AIR LEAVING
DURING COOLING OPERATION WHEN MODULATING COMPRESSOR IS AT MINIMUM
MODULATING HOT GAS REHEAT:
COMPRESSOR IS ON/OFF TYPE.
COMPRESSOR IS A MODULATING, VARIABLE SPEED SCROLL TYPE; THE SECOND
POINT BASED ON SUPPLY AIR TEMPERATURE SENSOR/TRANSMITTER (TS-02). ONE
LOAD AND UNLOAD AS REQUIRED TO MAINTAIN THE SUPPLY AIR TEMPERATURE SET
UNITS WITH TWO COMPRESORS: THE COMPRESSORS AND OUTDOOR FANS SHALL
FAN SHALL RUN WHENEVER THE COMPRESSOR IS RUNNING.
BASED ON SUPPLY AIR TEMPERATURE SENSOR/TRANSMITTER (TS-02). THE OUTDOOR
SPEED SCROLL) AS REQUIRED TO MAINTAIN THE SUPPLY AIR TEMPERATURE SET POINT
UNITS WITH ONE COMPRESSOR: THE COMPRESSOR SHALL MODULATE (VARIABLE
:COOLING/REFRIGERATION SYSTEM
(DPS-02) ACROSS THE FAN SHALL ISSUE A STOP COMMAND AND SIGNAL A FAN FAILURE.
FAILURE OF THE SUPPLY FAN AS DETERMINED BY A DIFFERENTIAL PRESSURE SWITCH
SET POIINT BASED ON SPACE TEMPERATURE SENSOR/TRANSMITTER (TS-01). A
SHALL VARY SPEED OF SUPPLY FAN (VFD-01) TO MAINTAIN THE SPACE TEMPERATURE
FAN SHALL OPERATE CONTINUOUSLY DURING OCCUPIED MODE. DDC CONTROLLER
: SUPPLY FAN
CONDITION.”OFF“DE-ENERGIZE, FURNACE SHALL SHUT-DOWN AND SIGNAL AN
SHALL CLOSE, SUPPLY FAN SHALL DE-ENERGIZE, REFRIGERATION SYSTEM SHALL
STOP: ON COMMAND TO STOP THE OUTDOOR AIR DAMPER AND RETURN AIR DAMPER
CONDITION.”ON“CONTROL SUPPLY FAN SPEED, MONITOR FILTERS AND SIGNAL AN
ALSO CONTROL COOLING/REFRIGERATION SYSTEM, CONTROL NATURAL GAS FURNACE,
END SWITCHES SIGNAL THAT THE DAMPERS ARE OPEN. DDC CONTROLLER SHALL
SETTING). SUPPLY FAN SHALL ENERGIZE ONCE THE OUTSIDE AIR AND RETURN AIR
DAMPER (AAD-02) OF RTU-SHALL OPEN TO NORMAL OPERATING POSITION (DESIGN AIR
START: ON COMMAND TO START THE OUTSIDE AIR (AAD-01) DAMPER AND RETURN AIR
COMPUTER AND RUN SUBJECT TO ITS SAFETIES.
RTU SHALL BE STARTED AND STOPPED FROM THE DDC CONTROLLER OR HOST
INTERFACE.
MANUFACTURER DDC CONTROLLER OR HOST COMPUTER THROUGH THE LONWORKS
THE RTU WILL BE INDEXED FOR OCCUPIED/UNOCCUPIED MODE THROUGH THE
AAD-01
PACKAGE DX ROOFTOP UNIT (RTU-1, -2, -3 & -4)
SEQUENCE OF OPERATION GENERAL NOTES
OR NOT EXPLICITLY STATED.
TIME DELAYS, ETC. SHALL BE ADJUSTABLE, WHETHER
ALL SET POINTS, THRESHOLD VALUES, ALARM LIMITS, B.
AND SYMBOLS.
SEE DRAWING M-001 FOR GENERAL NOTES, LEGEND A.
SA
F
IL
T E
R S
OA
PACKAGE DX ROOFTOP UNIT CONTROL DIAGRAM (RTU-1, -2, -3 & -4)
INTEGRAL TO ACU
BOUNDARY OF EQUIPMENT
RH/T
RH/T
O
IL
C O
O L
IN
G
D X
UNIT
CONDENSING
F U
R N
A C
E
G A
S
N A
T U
R
SPACE MOUNTED
WITH RTU
PROVIDED
CLOSE WITHIN 30 SECONDS OF ACTIVATION.
COMMAND WILL BE ISSUED. ALL EQUIPMENT MUST SHUT-DOWN AND DAMPERS MUST
DISTRIBUTION SHUT-OFF (ES-01) LOCATED INSIDE THE BUILDING IS ACTIVATED, A STOP
IF THE EMERGENCY AIR BUILDING EMERGENCY AIR DISTRIBUTION SHUT-OFF:
SWITCH TO OCCUPIED MODE.
OR FOR A PRESET TIME PERIOD (60 MINUTES, ADJUSTABLE), THEN THE UNIT SHALL
THE SELECTED SPACE TEMPERATURE SET POINT IS ACHIEVED (HEATING OR COOLING)
SHALL BE OPEN. UNIT SHALL OPERATE UNDER MORNING WARM-UP WITH UNTIL EITHER
START COMMAND. OUTSIDE AIR DAMPER SHALL BE CLOSED AND RETURN AIR DAMPER
AT THE CONCLUSION OF UNOCCUPIED MODE, THE DDC CONTROLLER SHALL ISSUE A
:WARM-UP MODE
DURING UNOCCUPIED MODE.
OUTSIDE AIR DAMPER SHALL BE CLOSED AND RETURN AIR DAMPER SHALL BE OPEN
UNOCCUPIED MODE.
SHALL ISSUE A STOP COMMAND. OUTSIDE AIR DAMPER SHALL BE CLOSED DURING
SATISFIED AND THE RTU HAS RUN FOR A MINIMUM RUN TIME, THE DDC CONTROLLER
ISSUE A START COMMAND. WHEN THE UNOCCUPIED TEMPERATURE SET POINT IS
OR BELOW THE HEATING SET POINT (55°F, ADJUSTABLE), DDC CONTROLLER SHALL
MODE SPACE TEMPERATURE RISES ABOVE THE COOLING SET POINT (85°F, ADJUSTABLE)
CONTINUE TO MONITOR THE SPACE TEMPERATURE SENSOR. IF THE UNOCCUPIED
DURING PERIODS WHEN RTU IS SCHEDULED OFF, THE DDC CONTROLLER SHALL
:UNOCCUPIED SETBACK MODE
RESTARTING SHALL REQUIRE MANUAL RESET AT THE SMOKE DETECTOR.
SHALL ISSUE A "STOP" COMMAND AND INITIAL A SMOKE ALARM IF SMOKE IS DETECTED.
SMOKE DETECTORS LOCATED IN SUPPLY AND RETURN DUCTWORK (DSD-01, DSD-02)
SMOKE DETECTION (RTU-1, -2 & -4 ONLY):
FILTER ALARM WHEN THE PRESSURE DROP ACROSS THE FILTER REACHES A SET POINT.
A DIFFERENTIAL PRESSURE SWITCH (DPS-01) ACROSS THE FILTER SHALL INITIATE A
DIRTY FILTER ALARM:
FAN WITH VFD PROVIDED WITH THE RTU.
EXCESS BUILDING PRESSURE SHALL BE RELIEVED BY MEANS OF A POWERED EXHAUST
RELIEF AIR:
THE ECONOMIZER SEQUENCE WILL BE DISABLED WHENEVER OA TEMPERATURE IS
TO MAINTAIN THE SUPPLY AIR TEMPERATURE AND SPACE TEMPERATURE AT SET POINT.
DAMPERS (AAD-01 & AAD-02) SHALL MODULATE FROM MINIMUM TO 100% OA AS NEEDED
THE OUTDOOR AIR (RH/T-01) TO DETERMINE THE MOST EFFICIENT AIR SOURCE. THE
MEANS OF THE TEMPERATURE/HUMIDITY SENSORS IN THE RETURN AIR (RH/T-02) AND
THE DDC CONTROLLER SHALL COMPARE OUTSIDE AND RETURN AIR ENTHALPY BY
ECONOMIZER:
FLOW RATE BASED ON AIR FLOW SENSOR (AFS-01).
DAMPER AND RETURN AIR DAMPER SHALL MODULATE TO MAINTAIN THE OUTSIDE AIR
UNLESS OVERRIDDEN BY ECONOMIZER OR UNOCCUPIED MODE. THE OUTSIDE AIR
AND RETURN AIR DAMPERS SHALL OPEN TO THE DESIGN OUTSIDE AIR INTAKE POSITION
WHENEVER THE SUPPLY FAN IS RUNNING IN THE OCCUPIED MODE, THE OUTSIDE AIR
OUTSIDE AIR CONTROL:
RA
TS-02 AI - WITH RTU
TS-01 AI WITH RTU
SENSOR
SPACE TEMPERATURE
AIR
TEMPERATURE SENSOR SUPPLY
SS-01 DO - - SUPPLY FAN START/STOP WITH RTU
SETPOINT +/-
VFD-01
SPEED
SUPPLY FAN MOTOR VARIABLE
WITH RTU
RH/T-02 AI - WITH RTU
RH/T-01 AI WITH RTU
HUMIDITY SENSOR -OUTSIDE AIR
TEMPERATURE/RELATIVE
HUMIDITY SENSOR - RETURN AIR
TEMPERATURE/RELATIVE
STATUS, DI-ALARM
AO-SPEED, DO-START, DI-RUN
ES-01 DI DDC CONTRACTOR
DISTRIBUTION SHUT-OFF
BUILDING EMERGENCY AIR - -
BUILDING
COMMON FOR
LOCATED IN THE MNS LOC; SEE FIRE ALARM SHEETS FA113 FOR LOCATION AND FA506 FOR DETAILS.1.
NOTES:
NOTE 1
DO AS SCHEDULED - POWERED THROUGH RTU WITH RTU
AIR DAMPER
DAMPER ACTUATOR - RETURN
AAD-02
DO - - POWERED THROUGH RTU WITH RTU
AIR DAMPER
DAMPER ACTUATOR - RELIEF
AAD-03
EA
VFD-02
SPEED
EXHAUST FAN MOTOR VARIABLE
WITH RTU
STATUS, DI-ALARM
AO-SPEED, DO-START, DI-RUN
DI - DDC CONTRACTOR
SUPPLY AIR
DUCT SMOKE DETECTOR
DSD-01
DETECTION
SMOKE
DI - DDC CONTRACTOR
RETURN AIR
DUCT SMOKE DETECTOR
DSD-02
DETECTION
SMOKE
AI AS SCHEDULED DDC CONTRACTOR
AIR
AIR FLOW STATION - OUTSIDE
AFS-01
10%
SETPOINT +/-
AFS
DPS-03 DI - - VERIFY FAN ON/OFF STATUS WITH RTU
SENSOR FOR EXHAUST FAN
DIFFERENTIAL AIR PRESSURE
-0
-1
IS
S U
E D F
O R C
O N
S T
R U
C T
IO
N D
P
H
M H
IL
L
A
L L R
IG
H T S R
E S
E R
V E
D
C H
M H
IL
L A
N D I S N
O T T
O B
E U
S E
D
IN
W
H O
L E O
R I
N P
A R
T F
O R A
N Y O
T H
E R P
R O J E
C T W
IT
H
O U
T T
H E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N O
F C
H
M H
IL
L
T H
IS
D
O C
U M
E N
T
A N
D T
H E I
D E
A S A
N D D
E S
IG
N S I
N C
O R
P O
R A
T E
D H
E R
E
IN
A S A
N I
N S
T R
U M
E N
T O
F P
R O
F E
S S
IO
N A
L S
E R
V
IC
E
IS
T
H E P
R O
P E
R T
Y O
F R
E U
S E O
F D
O C
U M
E N
T S
1 2 3 4 5 6
B
C
D
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
1"0 c
PROJ
DATE
D A
T E
N O
D S
G N
D R
R E
V
IS
IO
N
C H
K
A P
V D
B Y
A P
V D
SHEET
DWG
A
R E
P A
IR
M
X H
A N
G A
R
M A
N S
F
IE
L D L
A H
M A
N G B
A S
E
A
IR
N
A T
IO
N A
L G
U A
R D
M A
N S
F
IE
L D
O H
IO
of pw://projectwise.ch2m.com:DEN001/Documents/669816&space;-&space;Repair&space;MX&space;Hangar/WIP/MX&space;Hangar&space;CAD/ME/Dlv/669816_M-613$PWURL
T
A Y
L O
R S
T R
E E
T S
U
IT
E
D A
Y T
O N
O H
IO
T E
L E (3
-0
F
A X (7
-9
C H
M H
IL
L H
D R J
V
M E
C H
A N
IC
IS
O S
T O
R A
G E F
A N
(D O
A S
C O
N T
R O
L D
IA
G R
A M
D
M A
G L E
Y
FEB 2019
M
W
IL
S O
N M
D R
A G
O N
M-613
AS SHOWN
B D
E S
IG
N S
U B
M
IT
T A
L
D R P
E A
R S
O
669816_M-613.dwg
GENERAL NOTES
OR NOT EXPLICITLY STATED.
TIME DELAYS, ETC. SHALL BE ADJUSTABLE, WHETHER
ALL SET POINTS, THRESHOLD VALUES, ALARM LIMITS, B.
AND NOTES.
SEE DRAWING M-001 FOR SYMBOLS, ABBREVIATIONS A.
ES-01 DI DDC CONTRACTOR
DISTRIBUTION SHUT-OFF
BUILDING EMERGENCY AIR - -
ACTIVATION.
ISSUED. ALL EQUIPMENT MUST SHUT-DOWN AND DAMPERS MUST CLOSE WITHIN 30 SECONDS OF
SHUT-OFF (ES-01) LOCATED INSIDE THE BUILDING IS ACTIVATED, A STOP COMMAND SHALL BE
IF THE EMERGENCY AIR DISTRIBUTION BUILDING EMERGENCY AIR DISTRIBUTION SHUT-OFF:
SWITCH (SCS-01) SHALL ISSUE A STOP COMMAND AND SIGNAL A FAN FAILURE.
TEMPERATURE SENSOR (TS-01). A FAILURE OF THE SUPPLY FAN AS DETERMINED BY A CURRENT
THE DDC CONTROLLER SHALL SEND A SIGNAL TO THE SUPPLY FAN TO START TO SUPPLY FAN:
SHALL CLOSE AND SIGNAL AN "OFF" CONDITION.
ON COMMAND TO STOP THE SUPPLY FAN SHALL DE-ENERGIZE, THE SUPPLY AIR DAMPER STOP:
IS OPEN AND SIGNAL AN "ON" CONDITION.
(SS-01) SHALL ENERGIZE ONCE THE SUPPLY AIR DAMPER END SWITCH SIGNALS THAT THE DAMPER
DUCTWORK IMMEDIATELY DOWNSTREAM OF THE FAN SHALL OPEN FULLY (100%). SUPPLY FAN
ON A COMMAND TO START THE SUPPLY AIR DAMPER (AAD-01) LOCATED IN THE SUPPLY AIR START:
ITS SAFETIES.
THE SUPPLY FAN SHALL BE STARTED AND STOPPED FROM THE DDC SYSTEM AND RUN SUBJECT TO
ISO STORAGE SUPPLY FAN (SF-1)
SEQUENCE OF OPERATION
ISO STORAGE SUPPLY FAN (SF-1) CONTROL DIAGRAM
DEVICE & POINT LISTING (SF-1)
ID TYPE DESCRIPTION REMARKS PROVISION
SS-01 DO DDC CONTRACTOR
(ADJUSTABLE)
SETPOINT
(ADJUSTABLE)
ALARM POINT
EXHAUST FAN START/STOP- -
INTAKE
AIR
DISCHARGE
SUPPLY
BUILDING
COMMON FOR
SCS-01 DI DDC CONTRACTORCURRENT SWITCH VERIFY FAN ON/OFF STATUS- -
AO - - DDC CONTRACTOR
AIR DAMPER
DAMPER ACTUATOR - EXHAUST
AAD-01 EMERGENCY SHUT-OFF
LOCATED IN THE MNS LOC; SEE FIRE ALARM SHEETS FA113 FOR LOCATION AND FA506 FOR DETAILS.1.
NOTES:
NOTE 1
TS-01 AI DDC CONTRACTOR
SETPOINT +/-
SENSOR
SPACE TEMPERATURE
-0
-1
IS
S U
E D F
O R C
O N
S T
R U
C T
IO
N D
P
H
M H
IL
L
A
L L R
IG
H T S R
E S
E R
V E
D
C H
M H
IL
L A
N D I S N
O T T
O B
E U
S E
D
IN
W
H O
L E O
R I
N P
A R
T F
O R A
N Y O
T H
E R P
R O J E
C T W
IT
H
O U
T T
H E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N O
F C
H
M H
IL
L
T H
IS
D
O C
U M
E N
T
A N
D T
H E I
D E
A S A
N D D
E S
IG
N S I
N C
O R
P O
R A
T E
D H
E R
E
IN
A S A
N I
N S
T R
U M
E N
T O
F P
R O
F E
S S
IO
N A
L S
E R
V
IC
E
IS
T
H E P
R O
P E
R T
Y O
F R
E U
S E O
F D
O C
U M
E N
T S
1 2 3 4 5 6
B
C
D
VERIFY SCALE
BAR IS ONE INCH ON
ORIGINAL DRAWING.
1"0 c
PROJ
DATE
D A
T E
N O
D S
G N
D R
R E
V
IS
IO
N
C H
K
A P
V D
B Y
A P
V D
SHEET
DWG
A
R E
P A
IR
M
X H
A N
G A
R
M A
N S
F
IE
L D L
A H
M A
N G B
A S
E
A
IR
N
A T
IO
N A
L G
U A
R D
M A
N S
F
IE
L D
O H
IO
of pw://projectwise.ch2m.com:DEN001/Documents/669816&space;-&space;Repair&space;MX&space;Hangar/WIP/MX&space;Hangar&space;CAD/ME/Dlv/669816_M-614$PWURL
T
A Y
L O
R S
T R
E E
T S
U
IT
E
D A
Y T
O N
O H
IO
T E
L E (3
-0
F
A X (7
-9
C H
M H
IL
L H
D R J
V
M E
C H
A N
IC
V
R
IA
B L E R
E F
R
IG
E R
A N
T F
L O
W
(V R
F
C O
N T
R O
L D
IA
G R
A M
D
M A
G L E
Y
FEB 2019
M
W
IL
S O
N M
D R
A G
O N
M-614
AS SHOWN
B D
E S
IG
N S
U B
M
IT
T A
L
D R P
E A
R S
O
669816_M-614.dwg
SA
F
IL
T E
R
RA
C O
IL
D X
FCU'S
ADDITIONAL
TO
(RCS)
CONTROL PANEL
REMOTE
VRF SYSTEM
INTERFACE)
(BACNET
TO BAS
FCU
BCC-1
BCC-2
HP-1 M
M
PUMP
CONDENSATE
INTEGRAL
SA
F
IL
T E
R
RA
C O
IL
D X
FCU'S
ADDITIONAL
TO
FCU
M
M
PUMP
CONDENSATE
INTEGRAL
ZONE CONTROLLER
MAINTAINED IN MEMORY FOR A PERIOD OF 12 MONTHS (ADJ.)
INPUTS FROM ALL CONTROL POINTS. LOG SHALL BE UPDATED HOURLY (ADJ.) AND
TRENDING AND STATUS LOG: BAS SHALL MAINTAIN LOG OF SETPOINTS AND
AN ALARM IS GENERATED IN THE VRF CONTROL PANEL.
THE VRF CONTROL PANEL SHALL SEND A GENERAL ALARM TO THE BAS WHENEVER
SYSTEM SHALL SHUT OFF.
POINT IS SATISFIED AND THE VRF SYSTEM HAS MET A MINIMUM RUN TIME, THE
THE VRF SYSTEM SHALL ACTIVATE. WHEN THE UNOCCUPIED TEMPERATURE SET
EACH ZONE. IF THE SPACE TEMPERATURE RISES ABOVE THE COOLING OR
CONTROL SYSTEM SHALL CONTINUE TO MONITOR THE SPACE TEMPERATURE OF
SETBACK MODE. DURING PERIODS WHEN THE VRF IS SCHEDULED OFF, THE
THE VRF SYSTEM SHALL BE CAPABLE OF BEING SCHEDULED FOR AN UNOCCUPIED
AND ACTIVATE AN ALARM TO THE BAS.
BUILT-IN SWITCH SHALL SHUT THE UNIT OFF IN THE EVENT OF A PUMP FAILURE
THE FCU'S SHALL BE PROVIDED WITH AN INTEGRAL CONDENSATE PUMP. A
POINTS AND MODES OF OPERATION.
SPACE TEMPERATURE. THE BAS WILL BE CAPABLE OF OVERRIDING ALL LOCAL SET
COOLING FROM THE ZONE CONTROLLER, THE FCU'S SHALL OPERATE TO MEET
SWITCHOVER AND FAN SPEED ADJUSTMENT. ON A CALL FOR HEATING OR
ZONE CONTROLLER SHALL BE PROVIDED WITH AUTOMATIC HEATING/COOLING
SHOWN ON THE PLANS).
ARE GROUPED INTO ZONES TO OPERATE UNDER A SINGLE ZONE CONTROLLER (AS
FROM THE ZONE CONTROLLER. MULTIPLE FCU'S WITHIN THE OPEN WORK AREA
THERMOSTAT WHICH SHALL ALLOW THE TEMPERATURE TO BE ADJUSTED LOCALLY
ALL FCU'S SHALL BE PROVIDED WITH A ZONE CONTROLLER WITH INTEGRAL
CONTROLLERS LOCATED IN THE SPACE (SEE BELOW).
THE OVERALL BUILDING COOLING AND/OR HEATING LOAD BASED ON THE ZONE
COMPRESSORS AND OUTDOOR FANS LOAD AND UNLOAD AS REQUIRED TO MEET
THE HP UNITS SHALL HAVE AN…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .