EXHIBIT_A-CLIN_Pricing_Summary.xlsx

XLSX spreadsheet 64 KB Posted

Attached to
Repair Maintenance Hangar, B102 Federal contract opportunity
Solicitation number
W9136419B7001
Issued by
Department of the Army Ohio Army National Guard

About this file

This solicitation is for repair and renovation services at Building 102, a maintenance hangar at Mansfield Air National Guard Base in Ohio. The project includes demolition and work on fire protection, mechanical, plumbing, electrical, and telecommunications systems. Exterior brick veneer and metal siding require renovation along with window and door replacement to meet energy efficiency and secure facility standards. The construction period is 577 calendar days with inspection and punch list. There are no optional items. Bids will be evaluated without discussion and awarded to the responsible bidder in accordance with FAR procedures. This procurement is set aside exclusively for small businesses with average annual revenue under $36.5 million in the past three years. The project value is estimated between $10-25 million. A pre-bid conference is scheduled for July 30, 2019 with bids due August 23, 2019. Interested parties must register in the System for Award Management and check the FedBizOpps website for solicitation documents and any amendments.

Use when determining which costs go against which CLIN (for CLIN's 0001 - 0004)

View the file

Other files for this federal contract opportunity

Other files attached to Repair Maintenance Hangar, B102, newest first.
File Type Posted
Bid_opening_attendance.pdf PDF
Abstract_B102_signed.pdf PDF
W91364-19-B-7001_0003.pdf PDF
RFI_24_attach2.pdf PDF
RFI_34.pdf PDF
RFI_24_attach1.pdf PDF
RFI_36.pdf PDF
RFI_28.pdf PDF
RFI_23.pdf PDF
RFI_17.pdf PDF
RFI_31.pdf PDF
RFI_26.pdf PDF
RFI_25.pdf PDF
RFI_27.pdf PDF
RFI_10.pdf PDF
RFI_14.pdf PDF
RFI_18.pdf PDF
RFI_13.pdf PDF
RFI_16.pdf PDF
RFI_04.pdf PDF
RFI_07.pdf PDF
RFI_06.pdf PDF
RFI_02.pdf PDF
Full_size_drawings_13.pdf PDF
Full_size_drawings_6b.pdf PDF
Full_size_drawings_17.pdf PDF
Full_size_drawings_4a.pdf PDF
Full_size_drawings_14.pdf PDF
RFI_01.pdf PDF
Full_size_drawings_7b.pdf PDF
Full_size_drawings_10.pdf PDF
Full_size_drawings_12.pdf PDF
Pre-Bid_Conference_slides_B102.pptx PPTX presentation
Pre-Bid_sign_in_sheet.pdf PDF
Attach7_Vol_6_Drawings_7.pdf PDF
Attach7_Vol_6_Drawings_8.pdf PDF
Attach8-Temp_Restrooms.pdf PDF
Attach7_Vol_6_Drawings_6.pdf PDF
Attach7_Vol_6_Drawings_13.pdf PDF
Attach4-Vol_3_Specs.pdf PDF
Attach7_Vol_6_Drawings_4.pdf PDF
Attach2-Vol_1_BOD_1a.pdf PDF
Attach7_Vol_6_Drawings_10.pdf PDF
Attach7_Vol_6_Drawings_1a.pdf PDF
Attach5-Vol_4_Specs.pdf PDF
Attach7_Vol_6_Drawings_11.pdf PDF
Attach7_Vol_6_Drawings_2.pdf PDF
Attach9-RFI_template.doc DOC document
Attach1-Scope_of_Work-B102.pdf PDF
Attach7_Vol_6_Drawings_3.pdf PDF
Show all 50

Repair Maintenance Hangar, B102 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLIN 0001 (524)

Category Description (524)Extended Description
General Conditions-DIV 1Mobilization/Demobilization (all-inclusive), Field Personnel (e.g. site superintendent, QA/QC/safety engineers), site cleanup, contractor temp facilities (e.g. trailer, etc), PPE, etc
Gutters & DownspoutsSteel downspouts, galvanized, round, corrugated, 5" diameter, 26 gauge
Fixed PartitionsMetal stud partition, non-load bearing, galvanized, 10' high, 3-5/8" wide, 20 gauge, 16" O.C., includes top & bottom track
Masonry PartitionsConcrete block partitions, normal weight blocks, 2000 psi, 8" x 8" x 16", tooled joints both sides, includes mortar, excludes scaffolding, horizontal reinforcing, vertical reinforcing and grout
Standard Interior DoorsFrames, steel, knock down, hollow metal, for welded frames, add
Sliding & Folding DoorsCeiling support, structural framing, entrance door/folding partition, shop fabricated, excl door track & hardware
Interior Door HardwareDoor hardware, mortise lockset, commercial, wrought knobs and full escutcheon trim, keyed, single cylinder, typical, grade 1
Compartments, Cubicles, & Toilet PartitionsPartitions, toilet, cubicles, ceiling hung, powder coated steel
Toilet & Bath AccessoriesToilet accessories, shower curtain rod, chrome, 1-1/4" diameter x 5'
Marker Boards & Tack BoardsMarkerboards, wall hung or free standing, 5' x 6' to 4' x 8'
Identifying DevicesSigns, letters, cast aluminum, 12" h x 1-1/4" deep
LockersLockers, steel, baked enamel, double tier box, 18" x 15" x 36"
Fire Extinguisher CabinetsFire equipment cabinets, portable extinguisher, single, steel box, recessed, D.S. glass in door, stainless steel door & frame, 8" x 12" x 27", excludes equipment
CountersEngineered stone countertops, color group B, 25" wide, 4" backsplash, minimum
CabinetsCustom cabinets, kitchen base cabinets, hardwood, prefinished, 4 drawers, 24" deep, 35" high, 24" wide, excl. countertops
Interior Stair FinishStair treads & risers, landings, smooth sheet rubber, 1/8" thick
Tile & Terrazzo Wall FinishesCeramic tile, walls, interior, thin set, 4-1/4" x 4-1/4"
Painting to WallsPaints & coatings, walls & ceilings, interior, concrete, drywall or plaster, latex paint, 3 coats, smooth finish, spray
Tile Floor FinishesCeramic tile, floors, glazed, thin set, color group 1, 12" x 12"
Resilient Floor FinishesFlooring, vinyl composition tile, marbleized, 12" x 12" x 3/32"
Painting and Staining FloorsPaints & coatings, floors, interior, acrylic sealer, two coats
Wall Base FinishesWall base, vinyl, straight or cove, standard colors, 4" high, 1/8" thick
Floor Toppings and Traffic MembranesComposition flooring, epoxy, heavy duty epoxy topping, 1/4" thick, over 10,000 S.F.
Gypsum Wallboard Ceiling FinishesSuspended ceiling system, 1-1/2" carriers, 24" O.C. with 1-5/8" channels, 16" O.C., incl. carriers
Acoustical Ceiling Tiles & PanelsComplete suspended ceilings, with z bar suspension, 5/8" mineral fiber tile, include standard suspension system, excl. 1-1/2" carrier channels
Painting and Staining CeilingsDry fall painting, ceilings, structural steel, bar joists or metal deck, two coat, spray
Metal Ceiling PanelsReinstall metal ceiling panels removed from Hangar Bay
Passenger ElevatorsHydraulic passenger elevators, base unit, standard finish, 1500 lb, 100 fpm, 2 stop
WaterclosetsWater closet, bowl only, wall hung, includes flush valve and seat
UrinalsUrinal, wall hung, vitreous china, with self-closing valve, siphon jet type
LavatoriesLavatory, wall hung, vitreous china, white, with backsplash, single bowl, 20" x 18", includes trim
SinksSink, service, wall, porcelain enamel on cast iron, roll rim, 24" x 20", includes faucet and drain
Showers/TubsShower, stall, rough-in, supply, waste and vent for above shower
Emergency FixturesEye and body wash stations, emergency body shower and eye wash station
Pipes & FittingsPipe, copper, tubing, 1/2" diam., type L, excludes couplings and hangers
Valves & HydrantsValves, bronze, ball, 150 lb., 1/2", soldered
Domestic Water EquipmentStorage tanks, steel, liquid expansion, painted, 752 gallon capacity, ASME
Insulation & IdentificationInsulation, pipe covering (price copper tube one size less than I.P.S.), rubber tubing flexible closed cell foam, 1" wall, 1/2" iron pipe size
Waste Pipe & FittingsPipe, plastic, PVC, 1-1/2" diameter, type DWV, schedule 40, excludes couplings and hangers
Vent Pipe & FittingsPipe, plastic, PVC, 1-1/2" diameter, schedule 40, includes couplings 10' OC, and hangers 3 per 10'
Compressed Air System (Non-Breathing)Pipe, steel, black, threaded, 3/4" diameter, schedule 40, Spec. A-53, includes coupling and clevis hanger assembly sized for covering, 10' OC
Trench Drain Pipe & FittingsPipe, plastic, PVC, 4" diameter, type DWV, schedule 40, excludes couplings and hangers
Gas Supply SystemPipe, steel, black, threaded, 3/4" diameter, schedule 40, A-106, grade A/B seamless, includes coupling and clevis hanger assembly sized for covering, 10' OC
Direct Expansion SystemsPipe, plastic, PVC, 1-1/4" diameter, schedule 40, excludes couplings and hangers
Air Distribution, Heating & CoolingL-1 thru L-4, Louver, aluminum, extruded, with screen, mill finish, dual combination, electric or pneumatic operation, intake or exhaust
Exhaust SystemsVent chimney, prefabricated metal, gas, double wall, galvanized steel, 4" diameter, U.L. listed
Air Handling UnitsDOAS-1, dedicated outside air unit, energy recovery wheel, 6 ton cooling, natural gas, 72 MBH output
Unit HeatersUH-2 - Space heater, cabinet, grilles, fan, gas fired, suspension mounted, gravity vent, propeller fan, 20 MBH output, includes controls, burner and thermostat, excludes piping
HVAC ControlsControl components, HVAC system, per control point, including chiller
Water Side Testing & Balancing - Heating & CoolingBalancing, water, fin tube and radiant panels, (Subcontractor's quote including material & labor)
Air Side Testing & Balancing - Heating & CoolingAllowance for Balancing
Destratification FansFans, roof exhauster, centrifugal, aluminum housing, bird screen, back draft damper, direct drive, 1/4" S.P., 320 CFM, 12" galvanized curb, 11" sq. damper
Main TransformersStructural concrete, in place, equipment pad (3000 psi), 10' x 10' x 12", includes forms(4 uses), Grade 60 rebar, concrete (Portland cement Type I), placing and finishing
Feeder incl Conc Ductbank TR-1 to FPElectrical underground ducts and manholes, PVC, conduit with coupling, 4" diameter, schedule 80, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete
Feeder incl Conc Ductbank TR-1 to MDP-1Electrical underground ducts and manholes, PVC, conduit with coupling, 4" diameter, schedule 80, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete
Receps & Devices from Equip ListDuplex receptacle, grounded, 120 volt, 20 amp
120V Devices & CircuitsQuad receptacle, isolated ground, quad, 20 amp
Branch WiringElectric metallic tubing (EMT), 3/4" diameter, to 15' high, incl 2 terminations, 2 field bend elbows, 11 beam clamps, and 11 couplings per 100 LF
Lighting EquipmentFixture A, Interior LED fixtures, 45 watt mounting hardware and connections
Fire Alarm SystemsFire Detection System, incl devices, conduit & wire
Public Address SystemsPublic address equipment, Bogen UTI312 Multi Zone Paging Controller
Public Address SystemsPublic address equipment, Bogen ZX3 3 Zone Expansion Modules
Public Address SystemsPublic address equipment, Bogan AMBSQ1 Self Amplified Speakers
Public Address SystemsPublic address equipment, Bogan AH15A Self Amplified Horns
Public Address SystemsTelephone cable, telephone twisted, PVC insulation, #18-2 conductor
Mass Notification SystemMass Notification System incl devices, conduit and wire
Grounding SystemsHand holes, precast concrete, with concrete cover, 2' x 2' x 2'-6" deep, excludes excavation, backfill and cast in place concrete
Fire Pump BldgElectric metallic tubing (EMT), 3/4" diameter, to 15' high, incl 2 terminations, 2 field bend elbows, 11 beam clamps, and 11 couplings per 100 LF
LOX ShopElectric metallic tubing (EMT), 3/4" diameter, to 15' high, incl 2 terminations, 2 field bend elbows, 11 beam clamps, and 11 couplings per 100 LF
Substructure & SuperstructureParachute Drying Tower Demo. - Building demolition, small buildings or single buildings, steel, includes 20 mile haul, excludes salvage, foundation demolition or dump fees
Masonry Veneer DemolitionSelective demolition, masonry, concrete block walls, unreinforced, 8" thick
Interior Construction & FinishesSelective demolition, gutting, building interior, commercial building, includes disposal, excludes dumpster fees, maximum
Mechanical SystemsHeat pump, air source, split, up thru 10 ton, selective demolition
Electrical SystemsTransformer, dry type, primary, 3 phase, to 600 V, 500 kVA, electrical demolition, remove, including removal of supports, wire & conduit terminations
Asbestos AbatementPreparation of asbestos containment area, pre-cleaning, HEPA vacuum and wet wipe, flat surfaces
PCB Ballast and Mercury Bulb DisposalBallast and Bulb Disposal Cost - Subcontractor Budget Quote
Site Demolition & RelocationsSelective demolition, saw cutting, pavement, up to 3" deep
Temporary Erosion & Sediment ControlSynthetic erosion control, silt fence, install and maintain, remove, 3' high
Bases & Sub-BasesBase course drainage layers, aggregate base course for roadways and large paved areas, stone base, compacted, 3/4" stone base, to 6" deep
Curbs & GuttersCast-in place concrete curbs & gutters, straight, steel forms, 6" high curb, 6" thick gutter, 24" wide, straight, includes concrete
Paved SurfacesConcrete paving surface treatment, 4500 psi, fixed form, unreinforced, 12' pass, 11" thick, includes joints, finishing, and curing
Marking & SignagePainted pavement markings, acrylic waterborne, white or yellow, 6" wide, less than 3000 LF
Fire Water Storage TanksSteel water storage tanks, ground level, 55,000 gallons, excl. foundation
Sanitary Sewer PipingPipe, plastic, PVC, 8" diameter, type DWV, schedule 40, excludes couplings and hangers
Sanitary Sewer Manholes & CleanoutsStorm drainage manholes, frames and covers, concrete, precast, 4' I.D., 4' deep, excludes footing, excavation, backfill, frame and cover
Other Sanitary SewerAllowance for Oil/water separators, complete system, non-traffic area, coalescing, above or below grade, polypropylene, 200 GPM, excludes excavation and backfill
Storm Sewer PipingPublic sanitary utility sewerage piping, piping DWV PVC, schedule 40, 10' length, 4" diameter, excludes excavation or backfill
Structural FrameColumn base plates, structural, light, 100-ton project, up to 150 lb each, A992 steel, shop fabricated, incl shop primer
Chiller and pipingTie-into existing, chilled water system
Pipe InsulationInsulation, pipe covering (price copper tube one size less than I.P.S.), fiberglass with all service jacket, 1" wall, 2-1/2" iron pipe size
HVAC ControlsControl components, HVAC system, per control point- chiller only
Water Side Testing & Balancing - Heating & CoolingAllowance for Balancing of system
Support for new chiller, Instrumentation, etc.

CLIN 0002 (529)

Category Description (529)Extended Description
Wall FoundationsExcavating, bulk bank measure, 1/2 C.Y. capacity = 40 C.Y./hour, backhoe, hydraulic, wheel mounted, excluding truck loading
Column Foundations & Pile CapsExcavating, bulk bank measure, 1/2 C.Y. capacity = 40 C.Y./hour, backhoe, hydraulic, wheel mounted, excluding truck loading
Fire Tank FdnFill, gravel fill, compacted, under floor slabs, 6" deep
Equipment Foundation Pad AllowanceEquipment Pad Foundation Allowance
Fire Pump Bldg SlabFill, gravel fill, compacted, under floor slabs, 6" deep
Wall Foundations-DemolitionSelective demolition, saw cutting, concrete, up to 3" deep
Column Foundations-DemolitionSelective demolition, saw cutting, concrete, up to 3" deep
Elevator Pit-DemolitionsSelective demolition, saw cutting, concrete, up to 3" deep
Miscellaneous Structures and EquipmentParking gates, barrier gate, non-programmable, with reader and 12' arm
Bases & Sub-BasesSidewalks, driveways, and patios, sidewalks, concrete, excludes base, for 4" thick bank run gravel base, add
Paved SurfacesSidewalks, driveways, and patios, sidewalk, concrete, cast-in-place with 6 x 6 - W1.4 x W1.4 mesh, broomed finish, 3000 psi, 4" thick, excludes base
Fencing & GatesFence, chain link industrial, galvanized steel, 6 ga. wire, 2-1/2" posts @ 10' OC, 8' high, includes excavation, in concrete, excludes barbed wire
Other Site ImprovementsCorner guards, pipe bumper for truck doors, concrete filled, 8' long, 8" diameter
Seeding, Sprigging, & SoddingSodding, bluegrass sod, on level ground, 1000 S.F.
0002B Geotechnical InvestigationGeotechnical Investigaition
Record "As-Built" DocumentsField Personnel, civil engineer
Record "As-Built" DocumentsAs-built Surveying
Traffic ControlBarricades, traffic cones, PVC, 28" high
Traffic ControlOutside Laborers, (Semi-Skilled)
PermitsAllowance for Permits
PermitsOhio EPA Asbestos Removal Notification Fee
PermitsOhio EPA Asbestos Removal Fee
CONSTRUCTION FACILITIES & TEMPORARY CONTROLOffice Trailer, furnished, rent per month, 32' x 8', with air conditioning, excl. hookups
CONSTRUCTION FACILITIES & TEMPORARY CONTROLMobilization or demobilization, delivery charge for small equipment on flatbed trailer, maximum
CONSTRUCTION FACILITIES & TEMPORARY CONTROLProject Signs, sign, high intensity reflectorized, buy, excl. posts
CONSTRUCTION FACILITIES & TEMPORARY CONTROLField Office Expense, office supplies, average
CONSTRUCTION FACILITIES & TEMPORARY CONTROLOffice Trailer, delivery + return, add per mile
CONSTRUCTION FACILITIES & TEMPORARY CONTROLField Office Expense, office equipment rental, average
CONSTRUCTION FACILITIES & TEMPORARY CONTROLComputer, PC
CONSTRUCTION FACILITIES & TEMPORARY CONTROLScheduling, computer-update, micro, incl. plots, maximum
CONSTRUCTION FACILITIES & TEMPORARY CONTROLTemporary electrical power equipment (pro-rated per job), connections, office trailer, 100 amp
CONSTRUCTION FACILITIES & TEMPORARY CONTROLStorage Boxes, rent per month, 40' x 8'
CONSTRUCTION FACILITIES & TEMPORARY CONTROLStorage Boxes, rent per month, 20' x 8'
CONSTRUCTION FACILITIES & TEMPORARY CONTROLToilet, portable, chemical, rent per month (one men, one women)
CONSTRUCTION FACILITIES & TEMPORARY CONTROLTemporary Fencing, chain link, rented up to 12 months, 6' high, 11 ga, over 1000'
OWNER FIELD OFFICE TRAILEROffice Trailer, delivery + return, add per mile
OWNER FIELD OFFICE TRAILEROffice Trailer, furnished, rent per month, 32' x 8', with air conditioning, excl. hookups
OWNER FIELD OFFICE TRAILERField Office Expense, office equipment rental, average
OWNER FIELD OFFICE TRAILERComputer, PC
OWNER FIELD OFFICE TRAILERTemporary electrical power equipment (pro-rated per job), connections, office trailer, 100 amp
OWNER FIELD OFFICE TRAILERMobilization or demobilization, delivery charge for small equipment on flatbed trailer, maximum
PERSONNAL PROTECTIVE EQUIPMENTFirst aid kits, 36 ingredients
PERSONNAL PROTECTIVE EQUIPMENTEye and body wash stations, portable eye wash station, 6 gallon
PERSONNAL PROTECTIVE EQUIPMENTPPE, vest, reflective
PERSONNAL PROTECTIVE EQUIPMENTPPE, hard hats
PERSONNAL PROTECTIVE EQUIPMENTPPE, eye protection, safety glasses
PERSONNAL PROTECTIVE EQUIPMENTPPE, gloves (reusable), neoprene coated, package of 12 pair
PERSONNAL PROTECTIVE EQUIPMENTPPE, ear protection, ear plugs, disposable, box of 200
SURVEYING, INSPECTIONS & TESTING3rd party inspections
SURVEYING, INSPECTIONS & TESTINGInspections & testing
JOB SITE CLEANUPCleaning Up, cleanup of floor area, final by GC at end of job
JOB SITE CLEANUPSelective demolition, rubbish handling, dumpster, 40 C.Y., 10 ton capacity, weekly rental, includes one dump per week, cost to be added to demolition cost
BUILDER'S INSURANCEBuilder's Insurance
Column FoundationsExcavating, bulk bank measure, 1/2 C.Y. capacity = 40 C.Y./hour, backhoe, hydraulic, wheel mounted, excluding truck loading

CLIN 0003 (522)

Category Description (522)Extended Description
Elevator PitExcavating, bulk bank measure, 1/2 C.Y. capacity = 40 C.Y./hour, backhoe, hydraulic, wheel mounted, excluding truck loading
Structural FrameStructural steel project, industrial buildings, masonry and steel bearing, A992 steel, shop fabricated, incl shop primer, simple connections
Floor Decks and SlabsMetal floor decking, steel, non-cellular, composite, galvanized, 1-1/2" D, 18 gauge
Roof Decks and SlabsMetal floor decking, steel, non-cellular, composite, galvanized, 1-1/2" D, 18 gauge
Other Roof ConstructionAllowance for misc steel supports for Mechanical Equipment attached to roof framing
Truss RetrofitAngle framing, structural steel, field fabricated, incl cutting & welding
Brick VeneerGrout, door frames, 3' x 7' opening, 2.5 CF per opening
Insulated Metal Wall PanelsScaffolding, steel tubular, regular, labor only to erect & dismantle, building exterior, wall face, 6'-4" x 5' frames, 1 to 5 stories, excludes planks
Insulation & Vapor RetarderWall insulation, rigid, fiberglass, unfaced, 1-1/2" thick, R6.5, 3#/CF
Exterior Louvers & ScreensWall louvers, galvanized steel, fixed blades, commercial grade
StorefrontsTube Framing, for window walls and storefronts, anodized aluminum, stock, flush tube frame
Other Exterior WindowsTube Framing, for window walls and storefronts, anodized aluminum, stock, flush tube frame
Solid DoorsFrames, steel, knock down, hollow metal, double, 14 ga., up to 3-7/8" deep, 6'-0" h x 7'-0" w
Overhead and Roll-Up DoorsDoors, overhead, commercial, stock, steel, heavy duty, sectional, manual, 24 gauge, 12' x 10' high
Exterior Door HardwareDoor hardware, panic device, for rim locks, single door, exit only
Sprinklers and Releasing DevicesSprinkler system valve alarm, 3" size, includes retard chamber, trim, gauges & alarm line strainer
Sprinkler Water Supply Equipment and PipingFire Pump and Enclosure
Standpipe Equipment & Piping2-way standpipe connection (FHV/FDC), polishd brass, 2-1/2"x 2-1/2"x6"
Fire Extinguishers DevicesFire extinguishers, dry chemical, pressurized, ABC all purpose type, portable, 9-1/2 lb
Foam Generating EquipmentEnviromental foam, foam generator, water source required
Flame Detection EquipmentFlame Detection Equipment - Material Only
Draft CurtainDraft Curtain - Provide and Install
Main SwitchboardsSwitchboards, main circuit breaker, 3 pole, 4 wire, 277/480 volt, 1200 amp
Interior Distribution TransformersTransformer, dry-type, 3 phase 480 V primary 120/208 V secondary, 150 kVA, K-13 rated
PanelsCircuit breakers, 1 pole, 480 V, 15 to 60 amp, FA frame, for feeder section
208V CircuitsWire, copper, stranded, 600 volt, #12, type THWN-THHN, in raceway
120V Circuits from Eqp ListWire, copper, stranded, 600 volt, #10, type THWN-THHN, in raceway
480V Feeders & EquipPull boxes, steel, type SC, 12" W x 12" H x 6" D, NEMA 1
Fire Protection Water DistributionWater supply distribution piping, ductile iron pipe, cement lined, mechanical joint, no fittings, 18' lengths, 10" diameter, class 50, excludes excavation or backfill

CLIN 0004 (COMM LOA)

Category Description (COMM LOA)Extended Description
Telecommunication SystemsVoice/Data outlets, single opening, excl voice/data devices
Telecommunication SystemsPatch panel, jack RJ-45/110 type, 48 ports
Telecommunication SystemsElectric metallic tubing (EMT), 1" diameter, to 15' high, incl 2 terminations, 2 elbows, 11 beam clamps, and 11 couplings per 100 LF
Telecommunication SystemsTelecoms Equipment Enclosure
Telecommunication SystemsConduit fittings for rigid galvanized steel, explosion proof, flexible coupling, 1" diameter, 12" long
Telecommunication SystemsVoice/Data outlets, two jack opening, excl voice/data devices
Telecommunication SystemsVoice/Data outlets, 4 jack opening, excl voice/data devices
Telecommunication SystemsOutlet boxes, pressed steel, 4-11/16" square
Telecommunication SystemsOutlet boxes, pressed steel, plaster rings, 4-11/16" square
Telecommunication SystemsVoice/Data wall plate, stainless steel, 1 gang, 4-port, excl voice/data devices
Telecommunication SystemsVoice/Data wall plate, stainless steel, 2 gang, 6-port, excl voice/data devices
Telecommunication SystemsUnshielded twisted pair (UTP) cable, solid, plenum, #24, 4 pair, category 6
Telecommunication SystemsUnshielded twisted pair (UTP) jack, RJ-45, category 6
Public Address SystemsVoice/Data outlets, two jack opening, excl voice/data devices
Public Address SystemsOutlet boxes, pressed steel, 4-11/16" square
Public Address SystemsOutlet boxes, pressed steel, plaster rings, 4-11/16" square
Public Address SystemsAllowance for wireless access points

File details come from the government source that posted it. Updated .