3280-20-A-1-108R.pdf
PDF 284 KB Posted
- Solicitation number
- W91364-08-B-0001
About this file
3280-20-A-1-108R
View the file
Other files
Show 40 more
Latest 50 of 206 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-1-301
A-1-301
A-1-301
A-1-301
A-1-301
A-1-301
A-1-301
A-1-301
A-1-302R
A-1-302R
A-1-302R
A-1-302R
A-1-302R
A-1-302R
A-1-304
A-1-304
A-1-301
A-1-301
A-1-303
A-1-303
A-1-303
A-1-303
A-1-303
A-1-303
A-1-303
A-1-303
S L O
P E
/4 :1
S L O
P E
/4 :1
S L O
P E
/1 :1
S L O
P E
/1 :1
S L O
P E
/4 :1
S L O
P E
/4 :1
S L O
P E
/4 :1
S L O
P E
/4 :1
2'-6" X 3'-0" ROOF ACCESS
HATCH. (SEE SPECS)
24"X24" ROOFTOP
WALKWAY PADS
@ 28" O.C. TYP.
24"X24" ROOFTOP
WALKWAY PADS
@ 28" O.C. TYP.
30" WIDE X 5'-8" HIGH
ROOF SHIPS LADDER.
(SEE SPECS)
13 13 13 13
13 13 13 13
13 13
040303 0303
30" WIDE X 2'-8" HIGH
ROOF SHIPS LADDER.
(SEE SPECS)
30" WIDE X 8'-6" HIGH
ROOF SHIPS LADDER.
(SEE SPECS)
GRAVEL STOP EDGE AT TOP
OF WALL - SEE 4/A-1-307 FOR
TYPICAL WALL SECTION
GRAVEL STOP EDGE AT TOP
OF WALL - SEE 1/A-1-309 FOR
TYPICAL WALL SECTION
GRAVEL STOP EDGE AT TOP
OF WALL - SEE 1/A-1-310 FOR
TYPICAL WALL SECTION
05 05
05 05
1 1
1 1
SLOPE INSULATION AS
REQUIRED TO MATCH
ADJACENT ROOF
1 11
1 1
1 1 1
14 14
14 14
14 14
1 1 1
08 (TYPICAL)
08 (TYPICAL)
08 (TYPICAL)
08 (TYPICAL)
08(TYPICAL)
R
IG
ID
I N
S U
L A
T
IO
N
R
IG
ID
I N
S U
L A
T
IO
N
R
IG
ID
I N
S U
L A
T
IO
N
R
IG
ID
I N
S U
L A
T
IO
N
R
IG
ID
I N
S U
L A
T
IO
N
R
IG
ID
I N
S U
L A
T
IO
N
R
IG
ID
I N
S U
L A
T
IO
N
R
IG
ID
I N
S U
L A
T
IO
N
111111
1 1
GUTTER
APPROPRIATE FASTENER
PRIME FLANGE AND SET IN
MULTI-PURPOSE FLASHING CEMENT
MODIFIED BITUMEN GRANULE SURFACED CAP SHEET
FASTENERS AT APPROX. 3"
(76.2 mm) O.C. STAGGERED
INTERPLY AS REQUIRED BY MANUFACTURER MODIFIED BITUMEN GRANULE
SURFACED CAP SHEET
BASE AND INTERPLY SHEETS AS
REQUIRED FOR DESIRED WARRANTY
1. WOOD NAILER MUST BE INSTALLED TO
MEET APPLICABLE BUILDING CODES OR 200
LBS PER LINEAR FOOD MINIMUM IN ANY
GIVEN DIRECTION.
GUTTER DETAIL NOTES:
2. ATTACH WOOD NAILERS WITH
SUITABLE FASTENERS.
3. THIS DETAIL SHOULD BE USED ONLY
WHERE THE DECK IS SUPPORTED BY THE
OUTSIDE WALL.
4. ALL SHEET METAL IS TO BE INSTALLED
PER SMACNA GUIDELINES.
5. WOOD NAILER MUST EXTEND BEYOND
THE METAL FLANGE IN ALL DIRECTIONS.
INSULATION
METAL DECKING
3" 3" 3"
MIN
M
IN
MIN MIN
ANCHOR BOLT -
COUNTERSINK INTO
BLOCKING
/2
STEEL ANGLE WITH
EXPANSION BOLT
BASE AND INTERPLY
SHEETS AS REQUIRED BY
MANUFACTURER
GRANULE SURFACED
MODIFIED BITUMEN CAP
SHEET
INTERPLY REQUIRED FOR
15 & 20 YEAR SYSTEMS
GRANULE SURFACED MODIFIED
BITUMEN CAP SHEET
6" MIN FLANGE SET IN MULTI-
PURPOSE FLASHING CEMENT
OVER FIELD PLIES. (PRIME
FLANGE BEFORE STRIPPING)
TOP OF FLANGE CAPPED OR ROLLED
INTO PIPE APPROXIMATELY 1"
LEAD OR COPPER PIPE FLASHING
MULTI-PURPOSE FLASHING CEMENT
MIN MIN MIN
INSULATION
METAL DECKING
INSULATION
METAL DECKING
6" 3" 3"
FASTENER 12" O.C. MAX WITH
AP SEALANT (SEE NOTES)
INSULATION BY OTHERS
(M
IN
INSULATED METAL CURB
WOOD NAILER (SEE NOTES)
FASTEN APPROXIMATELY 8" O.C.
MECHANICAL UNIT
GASKETED FASTENER BY OTHERS 12" O.C. MAX
METAL COUNTERFLASHING BY
OTHERS 3" MIN FACE (SEE NOTES)
INTERPLY AS REQUIRED BY MANUFACTURER
METAL DECKING
INSULATION
MIN.
MODIFIED BITUMEN GRANULE
SURFACE CAP SHEET
BASE AND INTERPLY SHEETS AS
REQUIRED FOR DESIRED WARRANTY
METAL CURB DETAIL NOTES:
1. ATTACH NAILER TO DECK WITH SUITABLE FASTENER.
2. ALL SHEET METAL TO BE INSTALLED PER SMACNA
GUIDLINES.
3. GRANULES MUST BE EMBEDDED WHEN USING TORCH
APPLIED GRANULE SURFACED CAP SHEETS PRIOR TO
COMPLETING SIDE LAPS, END LAPS, AND BASE
FLASHING LAPS.
4. THE CURBS, TOP WOOD NAILER, AND SEAL STRIP
ARE TO BE SUPPLIED BY THE CURB MANUFACTURER.
5. WHEN POSSIBLE, THE MECHANICAL UNITS SHOULD
NOT BE SET UNTIL THE ROOF MEMBRANE AND FLASHING
HAVE BEEN INSTALLED.
3" 3"
MIN.
E N
G
IN
E E
R S
A
R C
H
IT
E C
T S
P
L A
N N
E R
S
A L L R
IG
H
T S
R E
S E
R V
E D
T H
IS
D
O C
U M
E N
T I S
T H
E P
R O
P E
R T
Y O
F
G R
W E
N G
IN
E
E R
S
IN
C A
N D
S H
A L
L N
O T
B E
R E
P R
O D
U C
E D
I N
W H
O L
E O
R I N
P A
R T
O R
U S
E D
F O
R C
O N
S T
R U
C T
IO
N
O F
O T
H E
R T
H A
N T
H
IS
S P
E C
IF
IC
P R
O J E
C T
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N w w w .g rw in c.
co m
SCALE:
SHEET NO.
DATE:
N O
R E
V
IS
IO
N
S
D E
S C
R
IP
T I O
N
S C
A L E
C H
E C
K
T H
IS
M
A R
K S
H O
U L D
M E
A S
U R
E E
X A
C T
L Y
W H
E N
P L O
T T
E D
D A
T E
B Y
D E
S
IG
N E
D
D R
A W
N
R E
V
IE
W E
D
A P
P R
O V
E D
G R
W P
R O
J E
C T
N O
C L
IE
N T
P R
O J E
C T
N O
F A
I SGR E
T R
E D
E
P
IP
E R
J R
S
A T
K
J A
M E
S
E T
O
H C
R
EC
IT
T
H
OI
O
As indicated
/3
/2
:2
:2
A M
C D o c u m e n ts a n d
S e tt in g s \j e n g la n d
\ D e s k to p \A
F R
C M o d e l.
rv t
O H
IO
A
R M
Y N
A T
IO
N
A L G
U A
R D
S
P R
IN
G
F
IE
L D
O
H
A-1-108R
J K
P
J K
P
J E
E
J K
P
A F
R C
R
O O
F P
L A
N
JULY 29, 2008
A R
M E
D F
O R
C E
S R
E S
E R
V E
C E
N T
E R
F
IE
L D
M A
IN
T
E N
A N
C E
S H
O P
-2
3/32" = 1'-0"1
ROOF PLAN
GENERAL NOTES:
SYMBOL KEY:
KEY NOTES:
00 DOOR MARK, SEE DOOR SCHEDULE SHEET A-1-601.
00 WINDOW MARK, SEE WINDOW SCHEDULE SHEET A-1-602.
00 KEYNOTE, SEE KEYNOTE SCHEDULE THIS SHEET.
A-0-000
DETAIL KEY, SEE CORRESPONDING DETAIL FOR MORE
INFORMATION.
W0 WALL TYPE
ELEVATIONS INDICATED: ASSUME A FINISH FLOOR
ELEVATION OF 0'-0". SEE CIVIL PLANS FOR ACTUAL
FINISH FLOOR ELEVATION.
4.
FURNITURE INDICATED IS (N.I.C.) UNLESS NOTED
OTHERWISE.
5.
TAPERED ROOF INSULATION 3" THICK AT ROOF DRAIN -
SLOPE 1/4" PER 1'-0" UNLESS NOTED OTHERWISE
PREFINISHED FORMED METAL COPING.
PREFINISHED METAL DOWNSPOUT - SEE ADDITIONAL
LOCATIONS ON EXTERIOR ELEVATIONS
PREFINISHED FORMED METAL GUTTER.
LINE OF STANDING SEAM METAL CANOPY (BELOW)
ENTRANCE CANOPY WITH RADIUS STANDING SEAM METAL
ROOF
ROOF ACCESS HATCH. SEE SHEET A-1-313.
WALKING PADS TO AND AROUND ROOF MOUNTED
EQUIPMENT - CONFIRM LOCATION FOR MAINTENANCE
ACCESS POINTS.
METAL (PAINT) ROOF ACCESS LADDER. SEE SHEET A-1-313.
NOT USED.10.
MECHANICAL UNIT: REFER TO EQUIPMENT CURB
DETAIL 4/A-1-108
11.
GRAVEL - STOP EDGE: SEE 5/A-1-313 FOR ROOF TO WALL
DETAIL
12.
PROVIDE ROOF INSULATION CRICKET - SLOPE 1/8"
PER 1'-0" - SEE 5/A-1-312.
14.
ROOF DRAIN13.
6.
3" = 1'-0"2
GUTTER DETAIL
3" = 1'-0"3
PLUMBING VENT DETAIL
3" = 1'-0"4
METAL CURB DETAIL
ALL DIMENSIONS ARE TO FACE OF EXPOSED BLOCK, FACE OF
EXPOSED BRICK OR TO FACE OF GYP. BOARD UNLESS NOTED
OTHERWISE.
SEE AREAS OF DETAIL FOR ADDITIONAL DIMENSIONS AND
DETAIL.
1.
2.
PROVIDE A FLUSH TRANSITION BETWEEN FLOOR FINISHES.
SEE FINISH SCHEDULE.
3.
01.
03.
04.
05.
06.
07.
08.
09.
02.
ALL INTERIOR WALLS SHALL EXTEND TO BOTTOM OF ROOF
DECK UNLESS NOTED OTHERWISE. PROVIDE CONTINUOUS
FIRE STOPPING AT TOP OF WALL SEALING ALL VOIDS TO
PROVIDE AIR TIGHT SEAL ON EACH SIDE OF WALL.
R E
V
IS
E D
R O
O F
P L A
N -2
-0
J E
E
File details come from the government source that posted it. Updated .