3280-20-A-1-107R.pdf

PDF 385 KB Posted

Attached to
CONSTRUCT ARMED FORCES READINESS CENTER AND FIELD MAINTENANCE SHOP, SPRINGFIELD, OHIO
Solicitation number
W91364-08-B-0001
Issued by

About this file

3280-20-A-1-107-R

View the file

Other files

File Type Posted
3280-20-E-1-301 Layout1 —
3280-20-E-1-601 Layout1 —
3280-20-E-2-203 Layout1 —
3280-20-A-1-108R.pdf PDF
3280-20-A-1-601R.pdf PDF
AMENDMENT 5SEP08.pdf PDF
Response to pre bid questions and amendment items .pdf PDF
3280-20-E-2-401 Layout1 —
3280-20-E-1-302 Layout1 —
3280-20-E-1-202 Layout1 —
3280-20-A-3-101R.pdf PDF
3280-20-E-2-601 Layout1 —
3280-20-E-1-603 Layout1 —
Revised 01810 GENERAL COMMISSIONING REQUIREMENTS.pdf PDF
3280-20-C-1-200 C-200 —
3280-20-E-1-801 Layout1 —
3280-20-M-1-101R Layout1 —
3280-20-A-1-302R.pdf PDF
3280-20-E-1-103 Layout1 —
08380_DOUBLE SWING DOORS.pdf PDF
15856 Gravity Ventilators.pdf PDF
3280-20-E-2-301 Layout1 —
3280-20-E-1-602 Layout1 —
3280-20-C-1-400R.pdf PDF
3280-20-E-1-304 Layout1 —
3280-20-E-0-101 Layout1 —
3280-20-C-1-300 C-300 —
3280-20-E-2-602 Layout1 —
3280-20-E-1-401 Layout1 —
3280-20-F-1-501R Layout1 —
3280-20-E-2-402 Layout1 —
3280-20-E-1-201 Layout1 —
3280-20-E-1-303 Layout1 —
100 Construction Documents Specifications.pdf PDF
3280-20-E-1-101.pdf PDF
3280-20-E-0-102.pdf PDF
amendment one 21aug08.pdf PDF
h5s45400.PDF PDF
3280-20-E-1-701.pdf PDF
3280-20-C-1-401.pdf PDF
3280-20-A-1-502.pdf PDF
3280-20-F-1-101.pdf PDF
3280-20-A-1-503.pdf PDF
3280-20-A-2-503.pdf PDF
3280-20-M-1-601.pdf PDF
3280-20-S-2-101.pdf PDF
3280-20-A-2-303.pdf PDF
3280-20-A-1-501.pdf PDF
3280-20-Q-1-101.pdf PDF
3280-20-A-1-313.pdf PDF
Show 40 more

Latest 50 of 206 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-1-301

A-1-301

A-1-301

A-1-301

A-1-301

A-1-301

A-1-301

A-1-301

A-1-405

A-1-302R

A-1-302R

A-1-302R

A-1-302R

A-1-302R

A-1-302R

A-1-304

A-1-304

A-1-301

A-1-301

A-1-303

A-1-303

A-1-303

A-1-303

A-1-303

A-1-303

A-1-303

A-1-303

A-1-404

W16X40

TYP.

TYP.

05050105

05050505050505

3027 SF

UNHEATED STORAGE

9101 SF

LOCKERS & HEATED

STORAGE

756 SF

ARMS VAULT

121A

101 SF

SUPPLY OFFICE

121C

102 SF

SUPPLY OFFICE

121B

255 SF

CORRIDOR D

121D

1429 SF

CORRIDOR B

797 SF

PHYSICAL FITNESS

ROOM

1133 SF

MECHANICAL ROOM

919 SF

ELECTRICAL ROOM

1146 SF

CORRIDOR C

374 SF

TELECOM / INFO

1130 SF

FACILITY MAINTENANCE

& RECYCLE ROOM

100 SF

OFFICE

112A

782 SF

KITCHEN

S

F

W A

R E

W A

S H

E

166 SF

SERVING

112F

184 SF

CORRIDOR E

64 SF

UNISEX TOILET

110A

552 SF

BREAK / VENDING

100 SF

SUPERVISOR

2084 SF

MAINTENANCE

TRAINING BAY

199 SF

TOOLS

108A

294 SF

SUPPLY

108B

832 SF

CLASSROOM

953 SF

CLASSROOM

1119 SF

CLASSROOM

S

F

C O

R R

ID

O

R F

1429 SF

CORRIDOR B

364 SF

MEN'S LOCKER ROOM

123A

366 SF

MEN'S SHOWERS

123B

150 SF

A / V STOR.

101C

303 SF

CHAIR STOR.

101B

349 SF

CORRIDOR G

252 SF

CHAIR STOR.

101A260 SF

LADIES' RESTROOM

265 SF

LADIES' LOCKER ROOM

124A

170 SF

LADIES' SHOWERS

124B

1087 SF

CORRIDOR A

598 SF

LIBRARY / LEARNING

305 SF

CONFERENCE ROOM

127E

3674 SF

BATTALION HQ

484 SF

COPY AREA / MAIL

ROOM

127A

120 SF

XO

127B

120 SF

CSM

127C

121 SF

CHAPLIN

127D

120 SF

OPS OFFICER

127F

224 SF

COMMANDER

127G

121 SF

RECRUITING

130A

170 SF

RECRUITING

S

F

T R

A

IN

IN

G

A

ID

S T

O R

A G

E

B

253 SF

FSO

1108 SF

ENTRANCE LOBBY

71 SF

VESTIBULE

6307 SF

ASSEMBLY

S

F

C O

R R

ID

O

R F

1606 SF

HHC ADMN.

218 SF

CONFERENCE ROOM

103B

121 SF

CUSTODIAN

439 SF

MEN'S RESTROOM

889 SF

CLASSROOM

140 SF

COMMANDER

103C

121 SF

1ST SGT

103A

848 SF

C COMPANY ADMN.

140 SF

COMMANDER

102B

121 SF

1ST SGT

102A

DASH DOT LINE

INDICATES WALL TO

ROOF DECK - TYPICAL

DASH DOT LINE INDICATES WALL

TO ROOF DECK - TYPICAL

HEAVY DASH LINE INDICATES 3 HR FIRE

RATED WALL - UL DESIGN NO. U907

E N

G

IN

E E

R S

A

R C

H

IT

E C

T S

P

L A

N N

E R

S

A L L R

IG

H

T S

R E

S E

R V

E D

T H

IS

D

O C

U M

E N

T I S

T H

E P

R O

P E

R T

Y O

F

G R

W E

N G

IN

E

E R

S

IN

C A

N D

S H

A L

L N

O T

B E

R E

P R

O D

U C

E D

I N

W H

O L

E O

R I N

P A

R T

O R

U S

E D

F O

R C

O N

S T

R U

C T

IO

N

O F

O T

H E

R T

H A

N T

H

IS

S P

E C

IF

IC

P R

O J E

C T

W

IT

H O

U T

W R

IT

T

E N

P E

R M

IS

S

IO

N w w w .g rw in c.

co m

SCALE:

SHEET NO.

DATE:

N O

R E

V

IS

IO

N

S

D E

S C

R

IP

T I O

N

S C

A L E

C H

E C

K

T H

IS

M

A R

K S

H O

U L D

M E

A S

U R

E E

X A

C T

L Y

W H

E N

P L O

T T

E D

D A

T E

B Y

D E

S

IG

N E

D

D R

A W

N

R E

V

IE

W E

D

A P

P R

O V

E D

G R

W P

R O

J E

C T

N O

C L

IE

N T

P R

O J E

C T

N O

F A

I SGR E

T R

E D

E

P

IP

E R

J R

S

A T

K

J A

M E

S

E T

O

H C

R

EC

IT

T

H

OI

O

3/32" = 1'-0"

/4

/2

:2

:0

P M

C D o c u m e n ts a n d

S e tt in g s \j e n g la n d

\ D e s k to p \A

F R

C M o d e l.

rv t

O H

IO

A

R M

Y N

A T

IO

N

A L G

U A

R D

S

P R

IN

G

F

IE

L D

O

H

A-1-107R

J K

P

J K

P

J E

E

J K

P

A F

R C

F

IR

S

T F

L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

JULY 29, 2008

A R

M E

D F

O R

C E

S R

E S

E R

V E

C E

N T

E R

F

IE

L D

M A

IN

T

E N

A N

C E

S H

O P

-2

3/32" = 1'-0"1

FIRST FLOOR - MASTER PLAN

GENERAL NOTES:

CEILING SYMBOL KEY:

REFLECTED CEILING PLAN FOR COORDINATION, FINISHES

AND FIXTURE LOCATION ONLY. SEE MECHANICAL,

ELECTRICAL, AND SPECIFICATIONS FOR ACTUAL FIXTURES.

1.

2'x2' SUSPENDED ACOUSTICAL CEILING.

5/8" TYPE "X" GYPSUM BOARD CEILING / SOFFIT. SEE

CORRESPONDING DETAILS.

2 X 4 RECESSED FLORESCENT LIGHT FIXTURE, SEE

ELECTRICAL PLAN.

2 X 4 RECESSED FLORESCENT LIGHT FIXTURE, SEE

ELECTRICAL PLAN.

1 X 4 SURFACE / PENDANT MOUNTED LIGHT FIXTURE,

SEE ELECTRICAL PLAN.

RECESSED CAN LIGHT FIXTURE, SEE ELECTRICAL

PLAN.

SURFACE MOUNTED BATTER PACK, SEE ELECTRICAL

PLAN.

WALL MOUNTED LIGHT FIXTURE, SEE ELECTRICAL

PLAN.

HVAC RETURN GRILL. SEE MECHANICAL PLAN.

HVAC SUPPLY GRILL. SEE MECHANICAL PLAN.

CEILING MOUNTED FIRE SUPPRESSION HEAD. SEE FIRE

SUPPRESSION PLAN. REFER TO FIRE PROTECTION

DRAWINGS FOR ADDITIONAL INFORMATION

SIDE MOUNTED FIRE SUPPRESSION HEAD. SEE FIRE

SUPPRESSION PLANS.

ALL INTERIOR WALLS SHALL EXTEND TO THE UNDERSIDE OF

THE ROOF DECK UNLESS NOTED OTHERWISE. WALLS FIRE

SEPARATION WALLS SHALL BE PROVIDED WITH FIRE STOPPING

AT ALL PENETRATIONS' SEE FIRE SUPPRESSION PLANS.

2.

KEYNOTES:

CEILING MOUNT PROJECTOR

UNDERSIDE OF METAL CANOPY

WOOD PANELS AND STEEL FRAMING

GYP. BOARD (PAINT) SOFFIT

4"X6" PRE-FINISHED METAL DOWNSPOUT. TIE INTO

UNDERGROUND ROOF DRAIN COLLECTION SYSTEM. SEE

CIVIL PLANS FOR CONTINUATION AND DOWNSPOUT BOOT

DETAIL 5/A-2-308.

OPERABLE WALL AND TRACK

LADDER AND ROOF ACCESS HATCH

EXPOSED STEEL STRUCTURE - REFER TO STRUCTURAL

01.

03.

04.

05.

06.

07.

08.

02.

EXTEND WALL TO METAL ROOF DECK - FIRESTOP AT

TOP OF WALL. SEE FIRE RESISTANCE RATED

CONSTRUCTION NOTES ON SHEET A-1-101

3 HOUR FIRE WALL (UL DESIGN NO. U907) TO METAL

ROOF DECK - FIRESTOP AT TOP OF WALL. SEE FIRE

RESISTANCE RATED CONSTRUCTION NOTES ON

SHEET A-1-101

R

E V

IS

E

D R

E F

L E

C T

E D

C E

IL

IN

G P

L A

N -2

-0

J E

E

PROVIDE STEEL W8X31 WITH 5/16"X11" (LENGTH AS

REQUIRED TO SPAN CORRIDOR) STEEL PLATE - PROVIDE

10"X10"X1/2" STEEL BEARING PLATE AT EACH END WITH (2)

1/2" (DIA.) X 4" NELSON STUDS GROUTED SOLID. TOP OF

STEEL AS REQUIRED TO BE IN COURSING AND/OR SUPPORT

ROOF FRAMING. PROVIDE 12" WIDE GYP. BOARD AND METAL

FRAMING BULK HEAD 1" BELOW SUSPENDED CEILING

09.

File details come from the government source that posted it. Updated .