This document is a Question and Answer document related to a federal contract opportunity for Optical Tables for a Photonics Workshop. The key details are:

The Government has a requirement for five optical tables, with four tables measuring 4.9 by 10 feet and one table measuring 4 by 6 feet. The tables must meet specific requirements for surface material, mounting holes, working height, and vibration isolation. The tables and support frames are to be delivered to the loading dock at 7880 Leaf Rd, Fort Belvoir, VA and then moved and installed in the destination rooms. A site visit has been scheduled for June 21, 2024 to walk through the moving path. The solicitation is set aside for small businesses under NAICS code 337127 with a 500-employee size standard. Quotes are due by June 19, 2024 and the Government intends to award without discussions. Delivery of the tables and supports is required no sooner than August 1, 2024.

View the file

Other files for this federal contract opportunity

Other files attached to Optical Tables for Photonics Workshop, newest first.
File Type Posted
Attachment 3_carpet_tile_subfloor.jpg JPG image
Attachment 4_carpet_pile_thickness.jpg JPG image
B08 Question and Answer Document_Optical Tables_Rev1_17Jun2024.pdf PDF
Attachment 2_SITE VISIT_Optical Tables.pdf PDF
Attachment 1_Table Install Route.pdf PDF
Combined Synopsis-Solicitation_Optical Tables.docx DOCX document
A02 DOR_Optical Tables_SAM Posting.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Question and Answer Document

The following questions and answers are provided for informational purposes only:

Question 1 - Can you provide the moving path information from the loading dock of 7880 Leaf Rd, Fort Belvoir, VA to each of five destination rooms where the five optical tables will be set up?

Answer: Please see Attachment 1 - “Table Install Route”. It includes an illustration of the travel path between the loading dock and laboratory. The Government has tried to include as many relevant details as possible.

a. How far are the rooms from the loading dock?

Answer: The optics workshop is 400 feet walking distance from the loading dock.

b. Are there any space constraints to move the five optical tables to the destination rooms?

Answer: Yes, unfortunately the hallway is only 52 inches wide and the entrance to the workshop is only 38 inches wide, whereas the tables are between 58 and 60 inches wide. The Government is anticipating that the tabletops must be maneuvered in an orientation standing on their sides.

c. How wide are the doors?

Answer: The narrowest doorway is the entrance to the optics workshop, which is only 38 inches wide. The hallway in front of it is 114 inches wide, so it should be possible to orient each tabletop on its side on a dolly and angle it into the room.

Question 2 - Are the rooms same level as the loading dock?

Answer: Yes

Question 3 - Do the optical tables need to be moved through a freight elevator?

Answer: No

Question 4 - Do the optical tables need to be moved up/down the stairs?

Answer: No

Question 5 - Do you allow a visit to walk through the moving path from the loading dock to the destination rooms?

Answer: Yes. A site visit has been scheduled to take place on Friday, June 21, 2024, at 9:00 AM EDT at the Geospatial Research Lab, on the Humphreys Engineer Center compound at 7880 Leaf Rd, Alexandria, Virginia, 22315. The building is the Cude Building. Please see Attachment 2 - “Site Visit” document for additional information and required contractor information that must be submitted prior to the site visit.

At the current moment, the Government can provide a walk-through of most of the path leading all the way from the loading dock right up to the door entrance of the optics workshop.

Unfortunately, outside visitors cannot enter the workshop itself today because it is currently still a security-controlled area, but that will soon change. By mid-July it will be possible for the Government to bring outside visitors into the workshop. A 1:1 diagram of the optics workshop is included on slide 3 of Attachment 1 - “Table Install Route”.