Drawings.pdf
PDF 4 MB Posted
- Solicitation number
- W912WJ24B0006
About this file
This set of construction drawings and related federal contract opportunity describe an electrical upgrades project at a gatehouse in Fiskdale, Massachusetts. The U.S. Army Corps of Engineers, New England District is seeking bids from small businesses for upgrades to the existing electrical systems at the East Brimfield Lake Dam gatehouse, including replacing the switchboard, lighting panel, feeder circuit, and branch circuits. The estimated value of the project is between $250,000 and $500,000. The solicitation is scheduled for release in March 2023 under NAICS code 238210. The period of performance is anticipated to be approximately 180 days. The work will include replacing the switchboard, feeder circuit from the utility building, and branch circuit conductors from the switchboard and lighting panel to the first device. Optional items may also be replaced, such as floodlights, interior lighting fixtures, and a unit heater.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
p
N
M
L
K
J
H
G
F
E
D
C
B
A
I 2 I
I
I I. I I
3 I 4 I 5 I 6 I 7 I 8 I 9 I
US Army Corps of Engineers ®
New England District
GATEHOUSE ELECTRICAL UPGRADES
EAST BRIMFIELD LAKE
FISKDALE, MASSACHUSETTS
N 495
I- -
91 WORCES
��,.-,9 r:..._
- 9 \ � FISKDALE
'\SPRINGFIELD
20 1 19ol �o
--v_,1 __ v
1t-✓, EAST BRIMFIELD
--- , ________ -------- MA
-CT ___
STURBRIDGE
---1--------
91 ._ 1 RI
-------r39s Ii PROJECT
LOCATION
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE: JANUARY 2024
10 I 11 I 12 I 13 I 14 I 15
SHEET NO.
1 G-001
2 E-001
3 ED401
4 ED601
5 ES101
6 E-401
7 E-501
8 E-502
9 E-601
NO. DRAWING
NUMBER
1 TH-1-19/1
2 TH-1-19/2
3 TH-1-19/3
4 TH-1-21/2
I 16 I 17 I 18 I 19 I 20
INDEX TO DRAWINGS
DESIGN FILE SHEET TITLE
THA-EB-137 _ G-001.DWG COVER SHEET AND INDEX
THA-EB-137 _E-001.DWG ELECTRICAL LEGEND, SYMBOLS, ABBREVIATIONS &
GENERAL NOTES
THA-EB-137 _ED401.DWG ELECTRICAL DEMOLITION FLOOR PLANS
THA-EB-137 _ED601.DWG ELECTRICAL DEMOLITION ONE-LINE DIAGRAM
THA-EB-137 _ES101.DWG ELECTRICAL SITE PLAN
THA-EB-137 _E-401.DWG ELECTRICAL NEW WORK FLOOR PLANS
THA-EB-137 _E-501.DWG ELECTRICAL SCHEDULES & DETAILS I
THA-EB-137 _E-502.DWG ELECTRICAL SCHEDULES & DETAILS II
THA-EB-137 _E-601.DWG ELECTRICAL NEW WORK ONE-LINE DIAGRAM
INDEX TO FOR INFORMATION DRAWINGS
SHEET SHEET TITLE
45 EXTERIOR ELECTRICAL PLANS AND DETAILS
46 EXTERIOR ELECTRICAL INTAKE STRUCTURE AND SERVICE BRIDGE
47 INTAKE STRUCTURAL ELECTRICAL PLANS, SECTIONS AND DETAILS
49 UTILITY BUILDING PLUMBING, HEATING AND ELECTRICAL
SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENDATION AND APPROVAL
OF ALL DRAWINGS IN THIS SET AS INDEXED ON THIS SHEET
APPROVED FOR TECHNICAL ADEQUACY BY:
TECHNICAL LEAD ENGINEER DATE
REVIEWED BY:
CHIEF, GEOTECHNICAL/WATER RESOURCES BRANCH DATE
REVIEWED BY:
CHIEF. GEO-ENVIRONMENTAL ENGINEERING BRANCH DATE
APPROVAL RECOMMENDED BY:
CHIEF, DESIGN BRANCH DATE
APPROVED BY:
CHIEF. ENGINEERING DIVISION DATE
This project was designed by the U.S. Army Corps of Engineers. The initials or signatures and registration designations of individuals appear on these project documents, within the scope of their employment as required by ER 1110-1-8152.
US Army Corps of Engineers ® ci z ci "z •• C\I 0 z w�- ti ��s � w <( c3 >-::, ::, :::, zCl)Z 0 0 Cl)<( Cl) u - -, wCl Ur--
(!) � Z' - "' :,: w
� <(Cl i:
z z
1-w w
I en
SHEET ID
G-001
LL
t;;w:,::
Cl) z wCl
W912WJ24B0006
W 2W
J2 4B e6eddjmn Text Box
JMN
1 I 2 I 3 I 4 I 5 I 6 I 7 I 8 I 9 I 10 I 11
BUILDING GROUNDING GRID LEGEND CIRCUITRY, RACEWAYS
AND FEEDERS LEGEND A
p
)_ GROUND ROD
-- AFF
G GROUNDING CONDUCTOR EF EF ELECTRIC BRANCH FEEDER AFG UNDERGROUND -
"-II
EXOTHERMICALLY WELDED CONNECTION AHJ
- - E - - E - - ELECTRIC PRIMARY UNDERGROUND AHLI
v'e
BOLTED CONNECTION
AIC - - ES- -ES- - ELECTRIC SECONDARY UNDERGROUND
a a BUILDING SYSTEM GROUND BUS AL N
EF EF ELECTRIC FEEDER UNDERGROUND ANSI
E E ELECTRIC PRIMARY OVERHEAD
ARCH
- ES ES ELECTRIC SECONDARY OVERHEAD ATS
EXISTING EQUIPMENT LEGEND
ATC
DA
:J
AWG DIRECT BURIED DUCTBANK
IDENTIFIER BLDG
M DA
'IP
C
SYMBOLS OUT OF FUNCTION DENOTES EXISTING
CAT
CB
- XM "XM" ADJACENT TO EQUIPMENT DENOTES EXISTING
EQUIPMENT TO REMAIN. CKT
CL
XN "XN" ADJACENT TO EQUIPMENT DENOTES EXISTING CLF
EQUIPMENT TO BE REMOVED AND REPLACED WITH NEW. EQUIPMENT LEGEND COL L
XR "XR" ADJACENT TO EQUIPMENT DENOTES EXISTING CPT
TO BE RELOCATED AS SHOWN. CUT BACK AND/OR SURFACE MOUNTED PANELBOARD, REFER TO SCHEDULES CT
EXTEND EXISTING BRANCH CIRCUIT WIRING AND
cu CONDUIT AS REQUIRED SO AS TO PROVIDE A
WW FLUSH MOUNTED PANELBOARD, REFER TO SCHEDULES -
COMPLETE OPERATIONAL INSTALLATION. CUH
G WP DRY-TYPE TRANSFORMER- "T3" DENOTES SIZE, REFER TO XD "XD" ADJACENT TO EQUIPMENT DENOTES EXISTING 3 SCHEDULE. "WP" DENOTES WEATHERPROOF dB,DB
TO BE REMOVED. CUT BACK AND MAKE SAFE ALL
DWG K ASSOCIATED BRANCH CIRCUIT WIRING CONDUIT BACK
TO POWER SOURCE AND LABEL BREAKER IN D' DISCONNECT SWITCH (UNFUSED) EC
PANELBOARD AS SPARE. CONTRACTOR SHALL BE EF
RESPONSIBLE FOR MAINTAINING CIRCUITRY TO DEVICES IZI' DISCONNECT SWITCH (FUSED) EM UNAFFECTED BY DEMOLITION. -
!CB1! ENCLOSED CIRCUIT BREAKER. "1" INDICATES GATE NUMBER EMT
XL "XL" ADJACENT TO EQUIPMENT DENOTES RELOCATED
EXISTING AT NEW LOCATION
EPO
XS "XS" ADJACENT TO EQUIPMENT DENOTES EXISTING CIRCUIT BREAKER. SIZE AS INDICATED ON SCHEDULES ETD J TO BE REMOVED, STORED, CLEANED AND REINSTALLED ETR IN EXISTING LOCATION.
ETRL
UTILITY METER
F
- FLA
SURGE PROTECTIVE DEVICE FMC
GENERAL LEGEND FT
H Qr'-' CONNECTION FROM JUNCTION BOX TO ELECTRICAL EQUIPMENT GFI
GND,G
PHOTO LOCATION AND DIRECTION, "E-xxx" INDICATES qf21-2 GRMC PHOTO SHEET NUMBER. DUPLEX RECEPTACLE, "R21" INDICATES PANEL, "2" INDICATES, E-xxx HOA CIRCUIT NUMBER AND WP INDICATES WEATHERPROOF - HPF
IG
!CM ! ELECTRONIC CHECK METER IEEE
G
PLUMBING AND MECHANICAL EQUIPMENT DESIGNATION.
REFER TO EQUIPMENT SCHEDULE(S) ON SHEET E-501.
DESIGNATION "M44N-2" DENOTES BRANCH CIRCUIT INT DESIGNATION FOR EQUIPMENT.
KCMIL -
F RACEWAYS AND WIRING
HOMERUN TO PANELBOARD. "LP" INDICATES PANEL, "1,3" INDICATES CIRCUIT
LP-1,3
HI
NUMBERS, (20A, 1 P, UNLESS OTHERWISE INDICATED) NUMBER OF SLASH MARKS
INDICATE NUMBER OF #12AWG CONDUCTORS IN MINIMUM 3/4"C. NO SLASH
- MARKS INDICATE 2#12 & 1#12G-3/4"C UNLESS OTHERWISE INDICATED. 1.
NOTES:
1. GREEN GROUND CONDUCTOR NOT INDICATED BUT SHALL BE INCLUDED IN EACH
RACEWAY. SIZE SHALL BE #12AWG UNLESS INDICATED OTHERWISE. 2.
E
2. HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE (3)
PHASE CONDUCTORS (ONE PER PHASE) PLUS NEUTRAL AND GROUND
CONDUCTORS IN EACH CONDUIT. 3.
4. -
5.
D
C
B
A
I 12 I 13 I 14 I 15
GENERAL ABBREVIATIONS
AMPERES kVA,KVA KILOVOLT AMPERES AMERICANS WITH DISABILITIES ACT kW,KW KILOWATTS
ABOVE FINISH FLOOR LGT LIGHTING
ABOVE FINISH GRADE LFMC LIQUIDTIGHT FLEXIBLE METAL
AUTHORITY HAVING JURISDICTION CONDUIT
AIR HANDLING UNIT
AMPERE INTERRUPTING CAPACITY MCB MAIN CIRCUIT BREAKER
ALUMINUM MCC MOTOR CONTROL CENTER
AMERICAN NATIONAL STANDARDS MCP MOTOR CIRCUIT PROTECTOR
INSTITUTE MISC MISCELLANEOUS
ARCHITECT MLO MAIN LUGS ONLY
AUTOMATIC TRANSFER SWITCH NC NORMALLY CLOSED
AUTOMATIC TEMPERATURE CONTROL NEC NATIONAL ELECTRIC CODE (NFPA 70)
AMERICAN WIRE GAUGE NEMA NATIONAL ELECTRICAL
BUILDING MANUFACTURES ASSOCIATION
CONDUIT NFPA NATIONAL FIRE PROTECTION
CATALOG ASSOCIATION
CIRCUIT BREAKER NIC NOT IN CONTRACT
CIRCUIT NO NORMALLY OPEN OR NUMBER
CENTERLINE NTS NOT TO SCALE
CURRENT LIMITING FUSE p POLE
COLUMN PB PUSHBUTTON, PULL BOX
CONTROL POWER TRANSFORMER PNL PANEL
CURRENT TRANSFORMER POS PROVIDED UNDER OTHER SECTIONS
COPPER PT POTENTIAL TRANSFORMER
CABINET UNIT HEATER PVC POLYVINYL CHLORIDE
PWR POWER
DECIBEL QTY QUANTITY
DRAWING REQ'D REQUIRED
ELECTRICAL CONTRACTOR RMC RIGID METAL CONDUIT
EXHAUST FAN RMS ROOT MEAN SQUARED
EMERGENCY RNMC RIGID NON-METALLIC CONDUIT
ELECTRICAL METALLIC TUBING RTU ROOF TOP UNIT
s SPARE
EMERGENCY POWER OFF SCR SHORT CIRCUIT INTERRUPTING RATING
EXISTING TO BE DEMOLISHED SW SWITCH
EXISTING TO REMAIN TEL TELEPHONE
EXISTING TO REMOVED AND RELOCATE TMCB THERMAL MAGNETIC CIRCUIT
FUSE BREAKER
FULL LOAD AMPERES UG UNDERGROUND OR UNDERGRADE
FLEXIBLE METAL CONDUIT UL UNDERWRITERS LABORATORIES
FEET UON UNLESS OTHERWISE NOTED
GROUND FAULT INTERRUPTER UH UNIT HEATER
GROUND OR GROUNDING UPS UN INTERRUPTIBLE POWER SUPPLY
GALVANIZED RIGID METALLIC CONDUIT V VOLT
HAND, OFF, AUTOMATIC SWITCH w WIRE
HIGH POWER FACTOR WH WATER HEATER
ISOLATED GROUND WP WEATHERPROOF
INSTITUTE OF ELECTRICAL AND XFMR TRANSFORMER
ELECTRONIC ENGINEERS
,6. DELTA
y WYE
INTERLOCK 0 PHASE
THOUSAND CIRCULAR MILS
BRANCH CIRCUIT WIRING NOTES
ALTHOUGH ALL BRANCH CIRCUIT WIRING AND CONDUIT IS NOT SHOWN, IT IS THE
INTENT OF THESE DOCUMENTS THAT A COMPLETE BRANCH CIRCUIT WIRING SYSTEM
BE INSTALLED.
WIRING AND CONDUIT SHALL BE REQUIRED BETWEEN ALL OUTLETS INDICATED WITH
CIRCUIT NUMBERS AND PANELBOARD DESIGNATIONS.
WIRING IS SHOWN ON SHEETS ONLY FOR SPECIFIC ROUTES OR SPECIAL CONDITIONS.
ALL SWITCH CONTROLS SHALL BE PROVIDED WITH WIRING AND CONDUIT AS
REQUIRED.
A GREEN GROUNDING CONDUCTOR SHALL BE ROUTED WITH ALL BRANCH CIRCUITS.
VERIFY CONDUIT SIZE TO ENSURE IT CAN ACCOMMODATE ALL PHASES, NEUTRAL, AND
GROUND CONDUCTOR.
I 16 I 17 I 18 I 19 I 20
GENERAL NOTES
1. INTERRUPTIONS TO EXISTING ELECTRIC SERVICES AND SYSTEMS SHALL LIMITED TO 24
HOURS MAXIMUM AND AT A SCHEDULE APPROVED BY THE EAST BRIMFIELD LAKE DAM
PROJECT OFFICE.
2. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO HAVE THE PROPOSED
ELECTRICAL MATERIAL IN PLACE PRIOR TO DE-ENERGIZING POWER TO ANY USAGE
EQUIPMENT IN ORDER TO MINIMIZE ELECTRICAL CUT-OVER SHUT DOWN. THE
CONTRACTOR SHALL COORDINATE SHUT DOWN REQUIREMENTS WITH THE EAST
BRIMFIELD LAKE DAM PROJECT OFFICE TO BETTER UNDERSTAND CONSTRUCTION
EXPECTATIONS.
3. ALL WIRING SHALL BE RUN CONCEALED UNLESS SPECIFIED OTHERWISE.
4. ALL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER,
RECTILINEAR TO BUILDING STRUCTURE.
5. ALL COMPONENTS SHOWN ON THE RISER DIAGRAMS, BUT NOT ON THE PLAN OR VICE
VERSA, SHALL BE INCLUDED AS IF SHOWN ON BOTH.
6. CONDUIT HOME RUNS SHOWN ON THE DRAWING WITH MORE THAN 3 CURRENT
CARRYING CONDUCTORS ARE SHOWN DIAGRAMMATICALLY. THIS CONTRACTOR SHALL
NOT INSTALL MORE THAN 3 CURRENT CARRYING CONDUCTORS IN A RACEWAY UNLESS
INSTALLATION COMPLIES WITH ARTICLE 310 OF THE NFPA 70, NOTES TO AMPACITY
TABLES REGARDING CONDUCTOR ADJUSTMENT FACTORS. ELEMENTS OF THE
ELECTRICAL WORK SHALL BE INSTALLED SUCH THAT AT COMPLETION THE ELEMENT
SHALL BE "FULLY AND REASONABLY ACCESSIBLE".
7. ELEMENTS OF THE ELECTRICAL WORK INCLUDE, BUT ARE NOT LIMITED TO PANELS,
SWITCHBOARDS, MOTOR CONTROLS, TRANSFORMER, DISCONNECTS, JUNCTION
BOXES, AND ALL MAINTENANCE ACCESS POINTS INCLUDING CABLE PULL SPACE.
"FULLY AND REASONABLE ACCESSIBLE" SHALL BE DEFINED AS; CAPABLE OF BEING
ACCESSED FOR SERVICE, REPAIR OR REPLACEMENT BY AN AVERAGE SIZED
INDIVIDUAL, ON A LADDER IF NECESSARY, AND CAPABLE OF BEING SERVICED OR
REMOVED WITHOUT REMOVING, MODIFYING OR DISTORTING OTHER COMPONENTS OF
THE WORK OF OTHER TRADES. CONFLICTS WITH MEETING THIS REQUIREMENT SHALL
BE BROUGHT TO THE ATTENTION OF THE COR IN A TIMELY MANNER.
8. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR FOR EACH
BRANCH CIRCUIT, UNLESS NOTED OTHERWISE.
9. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT
THE SCOPE WILL FIT WITHIN THE EXISTING STRUCTURE IN THE MANNER INTENDED
AND SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE COR PRIOR TO
ANY ROUGH-INS, FABRICATION, OR PERFORMING ANY WORK IN THE AREA INVOLVING
DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH
INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA.
10. PROVIDE ITEMS REFERRED TO IN SINGULAR NUMBER IN CONTRACT DOCUMENTS IN
QUANTITIES NECESSARY TO COMPLETE WORK.
11. REFER TO NFPA 70E AND THE CONTRACT DOCUMENTS FOR REQUIRED ARC FLASH
LABELING REQUIREMENTS.
12. PERFORM WORK AND PROVIDE MATERIALS AND EQUIPMENT AS SHOWN IN THE
CONTRACT DOCUMENTS. COORDINATE ELECTRICAL WORK WITH ALL TRADES AND
SPECIFICATION SECTIONS.
13. GIVE NOTICES, FILE PLANS, OBTAIN PERMITS AND LICENSES, PAY FEES AND BACK
CHARGES, AND OBTAIN NECESSARY APPROVALS FROM AUTHORITY HAVING
JURISDICTION (AHJ) PRIOR TO INSTALLATION OF EQUIPMENT.
14. PERFORM WORK AS SHOWN IN THE CONTRACT DOCUMENTS, AS REQUIRED BY CODES,
REGULATIONS, STANDARDS, AND LAWS OF LOCAL, STATE, AND FEDERAL
GOVERNMENTS.
15. MATERIAL AND EQUIPMENT SHALL BE UL, NEMA, ANSI, IEEE, ADA & ABA LISTED FOR
INTENDED SERVICE. MATERIAL AND INSTALLATION SHALL MEET REQUIREMENTS OF
NATIONAL AND STATE ELECTRICAL CODES.
16. MAINTAIN RECORD DRAWINGS ON SITE. RECORD SET MUST BE COMPLETE, CURRENT,
AND AVAILABLE FOR INSPECTION AS REQUESTED BY THE COR.
17. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS.
PROVIDE INFORMATION AND COMPONENTS SHOWN ON RISER DIAGRAMS BUT NOT
SHOWN ON PLANS, AND VICE VERSA, AS IF EXPRESSLY REQUIRED ON BOTH.
18. ADDRESS QUESTIONS REGARDING DRAWINGS TO COR IN WRITING BEFORE AWARD OF
CONTRACT. OTHERWISE, COR INTERPRETATION OF MEANING AND INTENT OF
DRAWINGS SHALL BE FINAL.
19. DEVIATION FROM CONTRACT DOCUMENTS, OR PROPOSED SUBSTITUTION OF
MATERIALS OR EQUIPMENT FOR THOSE SPECIFIED, SHALL BE REQUESTED IN
SEPARATE LETTER, WHETHER DEVIATIONS ARE DUE TO FIELD CONDITIONS, STANDARD
SHOP PRACTICE, OR OTHER CAUSE.
20. BRANCH CIRCUIT WIRING MAY NOT BE SHOWN GRAPHICALLY ON DRAWINGS AND MAY
BE INDICATED BY CIRCUIT NUMBERS BESIDE FIXTURES, DEVICES AND EQUIPMENT.
PROVIDE COMPLETE WIRING SYSTEM WHETHER OR NOT INDICATED GRAPHICALLY.
PHASE BALANCE ALL PANELBOARDS IN THE FIELD.
21. ALL FIREPROOFING FOR ELECTRICAL PENETRATIONS SHALL BE PROVIDED BY THE
ELECTRICAL CONTRACTOR.
22. SYSTEMS FEEDERS AND BRANCH CIRCUITS WHICH PASS THROUGH ALTERED AREAS
AND SERVE OTHER AREAS SHALL BE MAINTAINED AS REQUIRED AND AS DIRECTED BY
THE ENGINEER.
23. FURNISH AND INSTALL NAMEPLATES ON ALL ELECTRICAL EQUIPMENT (SCREW ON
TYPE) AND TYPEWRITTEN SCHEDULES OF CIRCUITS IN ALL DISTRIBUTION
PANELBOARDS, PANELBOARDS, TRANSFER SWITCHES, TRANSFORMERS, AND
DISCONNECT SWITCHES.
24. ALL GROUNDING SHALL BE PERFORMED IN ACCORDANCE WITH NFPA 70.
m US Army Corps of Engineers ®
LU
�Cl z F 0..
ii:
u enLUCl
Si'.
et: <(:;;
0 0) z w " z 0 Cl LL.. "' z 0 0LU o 0 (_),-._ f- "' ti (!) � £3 �
� Z '
LU<( c3 - "' t;;
::, ::, f- :S: LU enZ
:::, z
� <( LJJ
en< 0 0 Cl i: :,:: - -, en u en
Lli >' _Jui
>' "' u >-: "' Oz en z >' z "' z oz o- LJJ <( t--LJJ 0 "'0 w Si'. z f-
(!) :,: z f- :,: :,: - LJJ �!li en zLJJ Cl -i Cl -i
� LJJ �LJJ f- LO z u r,..
(3 c2 Cl C)I z>-<o�w en r-- L1. 5 a:::
O o<(O cnzZ<C 0.. ::i -:;;
et:
O C!>�O uz>et:>-LUco O
:;; :,: ffi � et: LJJ 0 <( z u ui ::::i enLJJCl
(!) LJJ
<) '3 :;;_-wwet: - _J f- LL <(0:;; Cl � ci: � wcc� W f- LL en� 5w
:,:: LJJ
f- :;; Si'. u t:: :,: u� :;; LJJ LU a, "' z :,:: ::, u -i en -i
Cl) -w
Cl) I- _.o Oz ID :::!: _J
Cl) w oz zWwCl (!) Cl$ W
CI)
_.z _.o<(_ 01- -<(a:: - 1-> ow w a::
_. ID
WID
SHEET ID
E-001
Cl u..i -N en _z en <
W 2W
J2 4B e6eddjmn
N
M
L
K
J
H
G
F F1
E
D
C
B
A
A1
EXISTING 3/4"
CONDUIT [XD]
EXISTING 3/4" C.
UP TO ROOF
VENTILATOR
r ..r I�
EXISTING FLOODLIGHT
NO.2ON ROOF
EXISTING 3/4" C.
UP TO FLOODLIGHT
NO.2
EXISTING PENDANT
FIXTURE,
TYP.4
EXISTING 314" C .
EXISTING UNIT r:;\
HEATER [XM] \V
EXISTING 1 1/4" C.
l
UH FOR GATE HOIST/
CONTROLS
$M
I I I u
EXISTING 3/4" C.
I \ I l l I \ I r ..
EXISTING 3/4" C.
EXISTING 1" C.
EXISTING 3/4" C.
EXISTING EXTERIOR LIGHT,
TYP.2
EXISTING ROOF HATCH
ABOVE
EXISTING 3/4" C.
UP TO FLOODLIGHT
NO.1
-...__ EXISTING FLOODLIGHT
NO. 1 ON ROOF
7 8
PLAN
NORTH
ELECTRICAL DEMOLITION FLOOR PLAN - GATEHOUSE OPERATING FLOOR 83
SCALE: 3/8" = 1 '-0"
EXISTING EMERGENCY
BATTERY LIGHTING UNIT [XM]
EXISTING @
3/4"C
[XD] SWITCHBOARD
[XD]
I r-1- 1 I -�
IG
N
I I • �HT-;;;:J METERING 1-
¾ l<..;AtN��l,j GATE HOIST
I I I-
NO. 1 ACB
• GATE HOIST
I � -1.:..J ""i
NO. 2ACB
INCOMING
lt
. I • I SPACE HEATERS
LINE ACB __ --1 ACB AND
CONTACTORS
_I_J i;;;;;;;;;;;;;;;;;;;;;;;;;-o-o=o�o�o�o�o�o.__ _________ � FLOOR o
SLAB
3 '-Q" X 1 '-Q" X 1 '-Q"
AUXILIARY GUTTER AND
CONDUITS [XM]
0 2' 4'- - 8 ' - -
ELECTRICAL DEMOLITION SECTION - GATEHOUSE OPERATING FLOOR
SCALE: 3/8" = 1 '-0" 0 2' 4' - - 8' - -
F9
A9
1 0
EXISTING 3/4" C.
UP TO AUXILIARY
GUTTER
. ·- 4.
• 4 ••
EXISTING PENDANT
FIXTURE,
TYP.2
I I I I I I ________ ...J r--------, I I I I I i@
L------..J
--- EXISTING 3/4" C.
r-------, I I I I I I I I
EXISTING 3/4" C.
- __.., L------..J
TO EXISTING JELLY JAR,
LIGHT
·- � • 4
15 16 17 18 19 20
GENERAL SHEET NOTES:
1. THE EXISTING CONDITION FLOOR PLANS SHOWN ON THIS DRAWING WERE DEVELOPED FROM
HISTORIC RECORD DRAWINGS.
2. USE ALL REASONABLE MEANS TO DIVERT CONSTRUCTION WASTE AND DEMOLITION
DEBRIS/WASTE FROM LANDFILLS AND INCINERATORS AND TO FACILITATE THE RECYCLING OR
REUSE OF EXCESS CONSTRUCTION MATERIALS. REFER TO SPECIFICATION SECTION 01 74 19
CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL FOR ADDITIONAL INFORMATION.
3. RECYCLE ALL FLUORESCENT LAMPS, HID LAMPS, MECURY (Hg) CONTAINING THERMOSTATS AND AMPOULES, AND PCBs-CONTAINING BALLASTS AND ELECTRICAL COMPONENTS AS
DIRECTED BY THE CONTRACTING OFFICER. REFER TO SPECIFICATION SECTION 02 84 16
HANDLING OF LIGHTING BALLASTS AND LAMPS CONTAINING PCBs AND MERCURY FOR
ADDITIONAL INFORMATION.
4. REFER TO SHEET ED601 FOR DEMOLITION ONE-LINE DIAGRAM.
KEYNOTES:
OPTIONAL BID ITEM 0002: DISCONNECT AND REMOVE EXISTING FLOODLIGHT IN ITS ENTIRETY.
MAINTAIN ALL EXISTING CONDUIT, BOXES, AND TENONS FOR INSTALLATION OF NEW LED
FLOODLIGHT IN EXISTING LOCATION. EXISTING FLOODLIGHT SHALL REMAIN UNDER BASE
PROJECT SCOPE.
OPTIONAL BID ITEM 0003: DISCONNECT AND REMOVE EXISTING INTERIOR LIGHTING FIXTURE IN ITS ENTIRETY. MAINTAIN ALL EXISTING CONDUIT AND BOXES FOR INSTALLATION OF NEW LED FIXTURE IN EXISTING LOCATION OR EXTENSION TO NEW LED FIXTURE LOCATION(S). EXISTING
FIXTURE SHALL REMAIN UNDER BASE PROJECT SCOPE.
OPTIONAL BID ITEM 0004: EXISTING UNIT HEATER SHALL BE DEMOLISHED AND REMOVED IN ITS
ENTIRETY. DISCONNECT AND REMOVE ALL CONDUIT AND WIRES FROM EXISTING UNIT HEATER
AND ASSOCIATED DEVICES BACK TO THEIR SOURCE.
DEMOLISH EXISTING GATEHOUSE SWITCHBOARD AND EQUIPMENT WITHIN (i.e. LIGHTING PANEL, CONTACTORS). BRANCH CIRCUIT CONDUCTORS SHALL BE REMOVED TO FIRST DEVICE ON THE
CIRCUIT, REMAINDER SHALL REMAIN FOR REUSE. EXISTING BRANCH CIRCUIT CONDUIT,
FITTINGS, AND BOXES IN THE RUN SHALL BE RETAINED FOR REUSE WITH NEW CONDUCTORS.
PLAN
NORTH
ELECTRICAL DEMOLITION FLOOR PLAN - GATEHOUSE EL.655.00
SCALE: 3/8" = 1 '-0"
� GENERATOR
REMOTE
STATION
XM
XM�
UTILITY
BUILDING
GARAGE
I I
Do TOILET
D� L _J
HEATER ROOM
-1 j
OFFICE
0 2' 4 ' - - 8 ' - -
PLAN
ELECTRICAL EXISTING CONDITIONS FLOOR PLAN - UTILITY BUILDING
SCALE: 1/4" = 1 '-0" 0 2' 4'- - 8' - -
US Army Corps of Engineers ®
0 z " z.. "' 0 LU o f- "' � £3 �
LU<( c3 :::, :::, :::, enZ 0en< en - -, oz >' z
LJJ 0 "'0
z f- z f-
(!) :,: :,: :,: - LJJ
�!li en z LJJ Cl -i Cl -i
LJJLJJ f- LO z (.) ,._ c3 c2 0 C)I z>-<o�w en ,._ L1. 5 a:::
O o<( O cnzZ<C 0.. ::i - :;;
et: (!) •
O C!>�O uz>et: >-LUco O
:;; :,: ffi � et: LJJ 0 <( z (.)
cj z ti �f-z
"' z o-w Si'.Si'. (.)
(.)� LU a, (.) -i w Cl
Z' - "':S: LU
� <( Cl i:
Oz LJJ <(f- :;;
t:: :,::;; LJJ "' z :::, en -i en z c:::
0 ...I u..
z 1-
:J ::i:
w ...I c:::
w ...I w
SHEET ID
LU
Cl z 0..
(.) enLUCl et:<(:;;
0) u..
C'?
t;; LJJ :,:: en
Cl .. f-LJJ 0<i! z f--
Cl u..i -N en _z en <
ED401
W 2W
J2 4B e6eddjmn
N
M
L
K
J
H
G
F
E
D
C
B
A -
I 2 I
OFFICE DISTRIBUTION PANEL [XM]
400A, 120/20BV, 30, 4W
SPACE SPACE
3 I 4
SPACE
I 5 I 6
NATIONAL GRID OH
PRIMARY FEEDER [XM]
y
400A 400A
SPACE
l I r l
NATIONAL GRID POLE
MOUNTED UTILITY
TRANSFORMERS [XM]
1 J
� l 12 0/208V
• 7 I 1
XM
: r--0 #25165800
XM
250A ) SOD
225A I QB225
SPARE
I 7 I 8
XMr------, XM
) 100A 70A
250A 200A
XM
20kW/25kVA GENS ET
DIESEL FIRED
120/208V, 30, 60Hz
OFFICE MANUAL
TRANSFER SWITCH
) SOD
QB200
200A MCB,
120/208V, 30, 4W
OFFICE
I 9
250A ) SOD
225A
I
QB225
SPARE
I 10 I
250A ) SOD
225A I QB225
SPARE
11 I
250A 200A
) SOD
QB200
I
250A 200A
XMr-� u 200A
XM 30, 4W
200A MCB,
120/208V, 100A/40A
1P-30A i
EXISTING SES -------..____
XM
SIMPLEX .._____.,_
CONTROLLER
#S31016H 0----f
I XM
GATE HOUSE SWITCHBOARD [XD]
100A, 120/208V, 30, 4W
EXISTING SEWER
PUMP [XM]
HANDHOLE NO. 1
HANDHOLE NO. 2
EH
EH
I
0----f 100A 100A
-i----,---,---7-
100A 50A
CONTACTOR WITH --- _l -
110V COIL [XD] T
INTEGRAL
THERMOSTAT
I I
-+-�/ T\
/VVVV
7.5kW SPACE
HEATER [XM]
100A 30A
XM
100A 30A
I 7 I
L ---= l,__-�-xM I
I-- CONTROL -
CABIN ET
13.2 A
GATE HOIST
NO. 2 [XM]
GATE HOIST
NO. 1 [XM]
100A 30A
XD J_
�OA ML07
120/208V, ---1 30, 4W I
L _ _J
LIGHTING
PANEL
XM
l00PJ100A
UTILITY
BUILDING
_J
XM
125A MLO,
120/208V, 10, 3W
STORAGE
BUILDING
) SOD
QB200
I 14 I
,- EXISTING UNDERGROUND
SPARE CONDUIT
XM
200A MCB,
120/208V, 30, 4W
STORAGE
BUILDING
[NOT IN SERVICE]
15 I
A 1 "': i.-....:E=-=L=-=E::.:C:..:T:..:.R.:.:.l.::.CA:....:=-L ..:::D..:::E�M.:..:O:..:L:.:.IT....:l..,;;;O..,;_N;;_O,;;,_,;,_;,N;;;;;.E-..,;;;L�I N..,;,,;E;;;,,_,;;;_D.:.:.IA..,;_G::.:R...,;;A...,;,,; M.,;,,,,;.._ _________________________________________ _
'- � SCALE: N.T.S.
16 I 17 I 18 I 19 I 20
NOTES:
1. REFER TO SHEET E-001 FOR LEGEND, SYMBOLS,
ABBREVIATIONS, AND GENERAL NOTES.
2. COORDINATION FOR ALL INTERRUPTIONS TO EXISTING
ELECTRIC SERVICES & SYSTEMS AND COMMUNICATIONS SHALL BE
COORDINATED THROUGH THE CONTRACTING OFFICER
REPRESENTATIVE (COR). THE CONTRACTOR SHALL PROVIDE
72-HOURS NOTICE PRIOR TO ANY SERVICE INTERRUPTIONS. MAXIMUM
SERVICE INTERRUPTION TO GATEHOUSE ELECTRIC SERVICE(S)
PERMITTED IS 24-HOURS.
3. USE ALL REASONABLE MEANS TO DIVERT CONSTRUCTION
WASTE AND DEMOLITION DEBRIS/WASTE FROM LANDFILLS AND
INCINERATORS AND TO FACILITATE THE RECYCLING OR REUSE OF
EXCESS CONSTRUCTION MATERIALS. REFER TO SPECIFICATION
SECTION 01 74 19 CONSTRUCTION WASTE MANAGEMENT AND
DISPOSAL FOR ADDITIONAL INFORMATION.
LINETYPE DENOTES EXISTING EQUIPMENT TO
REMAIN.
- LINETYPE DENOTES EXISTING EQUIPMENT TO BE
REMOVED.
KEYNOTES:
DEMOLISH FEEDER CONDUCTORS FROM 1 OOA-3P CIRCUIT
BREAKER IN "UTILITY BUILDING" PANEL TO EXISTING GATE HOUSE
SWITCHBOARD. EXISTING CONDUIT, FITTINGS, AND
BOXES/UNDERGROUND STRUCTURES IN THE RUN SHALL BE
RETAINED FOR REUSE WITH NEW CONDUCTORS.
DEMOLISH EXISTING GATEHOUSE SWITCHBOARD AND
EQUIPMENT WITHIN (i.e. LIGHTING PANEL, CONTACTORS). BRANCH
CIRCUIT CONDUCTORS SHALL BE REMOVED TO FIRST DEVICE ON
THE CIRCUIT, REMAINDER SHALL REMAIN FOR REUSE. EXISTING
BRANCH CIRCUIT CONDUIT, FITTINGS, AND BOXES IN THE RUN
SHALL BE RETAINED FOR REUSE WITH NEW CONDUCTORS.
OPTIONAL BID ITEM 0004: EXISTING UNIT HEATER SHALL BE
DEMOLISHED AND REMOVED IN ITS ENTIRETY. DISCONNECT AND
REMOVE ALL CONDUIT AND WIRES FROM EXISTING UNIT HEATER
AND ASSOCIATED DEVICES BACK TO THEIR SOURCE.
m US Army Corps of Engineers ® ci wz ci -st z 0 LJ..
u..i� 0 z 0 0 I- N � f-- l) "'
<( >- <( l) �� 0 0:: f-- � z ' w <{ u - en >--f-- $ L\l w Cl'.) z _J z <( <( w Cl'.)<( 0 0 O'. I I _-, Cl'.) l) 0 f-- Cl'.)
w z ii:
l) en w 0
W.
. . ...J Cl) .. >- <( . � >- en ol-:
z►za::izozcnZ0orooo-W<c:r--w f-- f-- LlJ "' f-- ::, �$ Z $o,:�t::$ 0 -wSw ll o:::::ww··CfJ <! w co ClJ wZo::ZICD
Z�z o--;o--;o---;w7(1)<(
SHEET ID
ED601
W 2W
J2 4B e6eddjmn
W
S
X
X
C
B
C
B
X
C
B
X
X
X
X
X X
C
B
C
B
C
B
X
S
D
X
EAST BRIMFIELD LAKE
R
I
V
E
R
V
I
E
A
V
E
N
U
E
QUINEBAUG R
IVER
E
A
S
T
B
R
I
M
F
I
E
L
D
M
PROJECT OFFICE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
GATEHOUSE
UTILITY BUILDING
GENERATOR
P
A
R
K
I
G
O
T
GRAVEL AREA
PROPERTY LINE
P
A
R
K
I
G
T
SERVICE
BRIDGE
FLOW
A
C
C
E
A
D
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
EXISTING HANDHOLE
NO. 1 [XM]
EXISTING HANDHOLE
NO. 2 [XM]
EXISTING 3"
CONDUIT [XM]
EXISTING 2"
CONDUIT [XM]
(2) EXISTING 3"
CONDUITS [XM]
(2) EXISTING 3"
CONDUITS [XM]
EXISTING 2-1/2" CONDUIT FOR POWER &
1" CONDUIT FOR LIGHTING [XM]
EXISTING 2"
CONDUIT [XM]
EXISTING POST LIGHTS
(TYP. 2) & 1" CONDUIT
BETWEEN [XM]
TEMPORARY CONSTRUCTION
STAGING AND STORAGE AREA
TEMPORARY CONSTRUCTION
CONTRACTOR PARKING
AREA
E
F
E
F
E
F
E
F
E
F
E
F
E
F
E
F
E
F
E
F
E
F
E
F
E
F
E
F
E
F
E
F
E
F
E
F
E L
E C
T R
I C
I T
E
P
L A
N
J N
E W
T O
N
J N
E W
T O
N
J B
R A
C K
I N
J N
E W
M A
N
A N
S I
D
J A
N U
A R
Y
US Army Corps of Engineers
U S
A
R M
Y
C
O R
P
F
E
N G
I N
E E
R S
N E
W
E
N G
L A
S
T R
I C
T
V
I R
G I N
A
D
C O
N C
O R
D
M
A
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
S C
A L E
S
H E
E T
D R
A W
I N
G
C
O D
E
C O
N T
R A
C
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
O F
SHEET ID
ES101
M A
R K
D E
S C
R I P
T I O
N D
A T
E
G A
T E
H O
U S
E
E
L E
C T
R I C
U
P G
R A
D E
S
E A
B
I M
F I E
K
E
F I S
K D
A L
E
M
A
T H
A E
B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SCALE: 1" = 50'
ELECTRICAL SITE PLAN
A1
50' 100'0
PLAN
NORTH
NOTES:
1. THE EXISTING CONDITION SITE PLAN SHOWN ON THIS DRAWING
WAS DEVELOPED FROM USACE SURVEYING DATA AND HISTORIC
RECORD DRAWINGS.
KEYNOTES:
ROUTE NEW CONDUCTORS WITHIN EXISTING CONDUIT(S)
BELOW GRADE. REFER TO NEW WORK ONE-LINE DIAGRAM ON
SHEET E-601 FOR ADDITIONAL INFORMATION.
W 2W
J2 4B e6eddjmn
C
N
(OPTIONAL
BID ITEM t------+--;a,-, M 0004)
L
EXISTING 3/4" C.
UP TO ROOF
VENTILATOR
NEW 'TYPE A' LED STRIP LIGHT
FIXTURE, HORIZONTALLY
MOUNTED@ 12'-0" AFF, TYP. 2
NEW 'TYPE C' LED FLOODLIGHT
ON ROOF ABOVE
EXISTING 3/4" C.
UP TO FLOODLIGHT
NO.2
EXISTING 3/4" C.
EXISTING UNIT
HEATER[XM]
I I I
$M �
NEW 'TYPE A' LED STRIP LIGHT
FIXTURE, VERTICALLY
MOUNTED @ 10'-0" AFF
I \ I l l I \ I r ..
EXISTING 1 1/4" C.
z
UH FOR GATE HOIST/
CONTROLS
u
>-+cc---"! nr---r f
K
J
NEW 'TYPE A' LED STRIP LIGHT
H FIXTURE, VERTICALLY
MOUNTED@ 12'-0" AFF
G
EX �TING 3/4
--- EXISTING 1-1/4"C. I
I FOR GATE : HOIST/CONTROLS
I
1---------- ,-------tr.---..-:u..-�l\
\ ( -- _ _Q
EXISTING 3/4" C.
EXISTING 3/4" C.
EXISTING 1" C.
EXISTING 3/4" C.
EXISTING EXTERIOR LIGHT,
TYP.2
EXISTING ROOF HATCH
ABOVE
EXISTING 3/4" C. UP TO
FLOODLIGHT NO. 1
NEW 'TYPE C' LED FLOODLIGHT
ON ROOF ABOVE
F F1
ELECTRICAL NEW WORK FLOOR PLAN - GATEHOUSE OPERATING FLOOR
SCALE: 3/8" = 1 '-0" 0 2' 4' - -
PLAN
NORTH
8' - -
E
D
C
B
A
A1
A I f©
EXISTING EMERGENCY
BATTERY LIGHTING UNIT [XM]
2#12&1#12G.- 3/4"C.
GATE
HOUSE
DISTRIBUTION
PANEL
SPD "GHDP"
BRANCH CIRCUIT/FEEDER
CONDUITS (TYPICAL)
WIREWAY WITH SCREW
COVER NEMA 3R ENCLOSURE,
SIZED AS REQURIED FOR THE
APPLICATION.
i;;;;;;;;;;;;;;;;;;;;;;;;;-
L
O U
O L
O
O
O '--r--------------------- FLOOR a SLAB
3'-Q" X 1 '-Q" X 1 '-Q"
AUXILIARY GUTTER AND
CONDUITS [XM]
ELECTRICAL NEW WORK SECTION - GATEHOUSE OPERA TING FLOOR
SCALE: 3/8" = 1 '-0" 0 2' 4' - - 8' - -
9 10
NEW 'TYPE A' LED STRIP LIGHT
FIXTURE, VERTICALLY
MOUNTED@ 10'-0" AFF,
TYP.4
EXISTING 3/4" C.
UP TO AUXILIARY
GUTTER
NEW 'TYPE A' LED STRIP LIGHT
FIXTURE, HORIZONTALLY
MOUNTED @ 8'-0" AFF
11 12 13 14
A
EXISTING JUNCTION
� BOX (TYP. 2) \
--------7
I I I I I I
________ ...J
.• t-----�
A
J
I I
I I I r-------, L..------...J
I
I��
I I
I I I
EXISTING 3/4" C
�L_ -_ -_-_-_-___ J�
A
.L:. �==="=-==.============,,=� ... °!, � '
•-�-. -. ·,;, •.4·
.. ",1 -, .. . .• •• :; q·d .•
TO EXISTING JELLY JAR,
LIGHT
15 16 17 18 19 20
GENERAL SHEET NOTES:
1. THE EXISTING CONDITION FLOOR PLANS SHOWN ON THIS DRAWING WERE DEVELOPED FROM
HISTORIC RECORD DRAWINGS.
2. REFER TO SHEET E-501 FOR PANELBOARD SCHEDULES AND SHEET E-601 FOR NEW WORK
ONE-LINE DIAGRAM.
KEYNOTES:
OPTIONAL BID ITEM 0002: MOUNT NEW LED FLOODLIGHT WITH SLIPFITTER BASE ON EXISTING
TENON MAINTAINED IN THE DEMOLITION PHASE. CONNECT TO NEW BRANCH CIRCUIT WIRING
INSTALLED IN EXISTING CONDUIT/BOXES UNDER BASE CONTRACT SCOPE.
OPTIONAL BID ITEM 0003: EXTEND EXISTING OPERATORS FLOOR LIGHTING BRANCH CIRCUIT
WIRING INSTALLED IN EXISTING CONDUIT/BOXES UNDER BASE PROJECT SCOPE TO NEW LED
STRIP LIGHT LOCATION(S) SHOWN. ALL NEW CONDUIT AND WIRING SHALL BE 2#12 & 1#12G. -
3/4"C. [RGS]. EXACT CONDUIT ROUTING SHALL BE FIELD COORDINATED. MOUNT NEW
STAIRWELL JELLY JAR FIXTURE ON EXISTING JUNCTION BOX MAINTAINED IN THE DEMOLITION
PHASE.
OPTIONAL BID ITEM 0003: EXTEND EXISTING SUB-FLOOR LIGHTING BRANCH CIRCUIT WIRING
INSTALLED IN EXISTING CONDUIT/BOXES UNDER BASE PROJECT SCOPE TO NEW LED STRIP
LIGHT LOCATION(S) SHOWN. ALL NEW CONDUIT AND WIRING SHALL BE 2#12 & 1#12G. - 3/4"C.
[RGS]. EXACT CONDUIT ROUTING SHALL BE FIELD COORDINATED.
PLAN
NORTH
F9
ELECTRICAL NEW WORK FLOOR PLAN - GATEHOUSE EL.655.00
A9
SCALE: 3/8" = 1 '-0"
� GENERATOR
REMOTE
,__ STATION
XM
XM-
UTILITY
BUILDING
GARAGE
I I
Do TOILET
D� L _J
HEATER ROOM
-1 j
OFFICE
0 2' 4' - - 8' - -
PLAN
ELECTRICAL EXISTING CONDITIONS FLOOR PLAN - UTILITY BUILDING
SCALE: 1/4" = 1'-0" 0 2' 4' - - 8' - -
US Army Corps of Engineers ®
0 z" z.. "' 0 LU o f- "' � £3 �
LU<( c3 enZ 0 en< en- -, oz >' z
LJJ 0 "'0
z f- z f-
(!) :,: :,: :,: - LJJ
�!lien z LJJ Cl -i Cl -i
LJJLJJ f- LO z (.) r-.
c3 c2 0 C)I z>-<o�w en r-.
L1. 5 a:::
O o<(O cnzZ<C 0.. ::i - :;;
et: (!) -
QC!)�D
uz>et: >-LU"' O
:;; :,: ffi � et: LJJ 0 <( z (.)
0 z ti �f-z
>' "' zo-w Si'. Si'. (.)
(.)�LU a, (.) -i w Cl
Z ' - "' :S: LU
� <( Cl i:
Oz LJJ <( f- :;;
t:: :,::;; LJJ "' z:::, en -i
Cl) z
0::
_J IL
0::
w z
_J
0::
w _J w
SHEET ID
E-401
LU
Cl z 0..
(.) enLUCl et: <(:;;
0)
LL
CD
t;; LJJ :,:: en
Cl .. f-LJJ 0 <i! z f-- Cl u..i -N en_z en <
W 2W
J2 4B e6eddjmn
2 3 4
N
M
L
K
J
H
G
F
E
D
C
B
A
5 6 7 8 9 10 11 12
ADAN GER .AWARNING
NO SAFE PPE EXISTS
ENERGIZED WORK PROHIBITED
Arc Flash and Shock Risk
Appropriate PPE Required
FLASH PROTECTION
Flash liozard ot 18 In �Im, Arc Ro ing• 156 callcm•2
NcflasnBooodaly
Glove Clos.s: 00
: 3$0 In
SHOCK PROTECTION'
Sood< Hozord when oover is r movact 480 VAC
Llm,100 APProoch 42 In
Resl/lcte<I Approacl\ 12 In
FLASH PROTECTION SHOCK PROTECTION
Flash Hazord Ill 18 In Shock Hazard when 208VAClin. Ate :Ro�ng. 1.2 eaucm•2 cover 15 remoYed
Ale F sh BO<Jndary 18 In L1m1ted Approach 42: In
Glove Class 00 Restncted Approach 12 In
Bus: MSA DISC. SW. Prot: MaxTrlpTlme C!2.0s
COMPANY NAME
PreQ.Mtl3 on. Oliler..(117
COMPANY NAME
Bus: LA2 Prot: DS-t..A2 DISC. SW. �-ea on. OYl&2011
ARC FLASH LABEL NOTES:
1. ARC FLASH WARNING LABELS SHALL BE PROVIDED FOR ALL EXISTING AND NEW TRANSFORMERS, DISCONNECT
SWITCHES, SWITCHBOARDS, AND PANELBOARDS AT THE SITE. REFER TO SPECIFICATION SECTION 26 05 73 POWER
SYSTEM STUDIES FOR FURTHER REQUIREMENTS.
2. LABELS SHALL BE 4 INCH X 6 INCH THERMAL TRANSFER TYPE OF HIGH ADHESION POL VESTER FOR EACH WORK
LOCATION ANALYZED AND SHALL BE MACHINE PRINTED WITH NO FIELD MARKING. THESE LABELS ARE SHOWN AS
EXAMPLE ONLY AND DO NOT REFLECT THE ACTUAL DATA FOR THIS PROJECT.
3. THE LABEL SHALL HAVE AN ORANGE HEADER WITH THE WORDING, "WARNING:SHOCK & ARC FLASH HAZARD" IF THE
CAL/CM2 IS LESS THAN 40 OR RED HEADER WITH THE WORDING "DANGER-DO NOT WORK ON LIVE " IF CAL/CM2 IS
GREATER THAN 40.
ELECTRIC UNIT HEATER SCHEDULE (OPTIONAL BID ITEM 0004)
EQUIPMENT TAG kW (BtuH) MOUNTING
EUH-1 10 (34,100) WALL
ELECTRIC CABINET UNIT HEATER SCHEDULE NOTES:
1. PROVIDE WITH INTEGRAL THERMOSTAT.
ELECTRICAL DATA MIN. THROW
(VOLT/PHASE/HERTZ) (FT)
208/3/60 20
NOTES
1,2,3
2. PROVIDE UNIT HEATER WITH MANUFACTURER RECOMMENDED WALL MOUNTING BRACKET ASSEMBLY. UNIT SHALL NOT BE INSTALLED AT A HEIGHT GREATER THAN THE MANUFACTURER'S REQUIREMENTS FOR ADEQUATE HEAT DISTRIBUTION.
3. PROVIDE WITH POWDER COATED STEEL HOUSING WITH WHITE FINISH.
(TYPICA L)
14 15 16 17 18 19
PANELBOARD SCHEDULE - POWER PANEL "GHDP"
FED FROM: UTILITY BUILDING NEUTRAL BUS: 100% TUB: SINGLE
VOLTAGE: 120/208V, 30, 4WIRE GROUND BUS: EQUIPMENT MOUNTING: SURFACE
AMPERE RATING: 100A AIC RA TING: 10,000 LOCATION: GATE HOUSE
MAINS: 100A-3P MCB BUSSING: COPPER ENCLOSURE: NEMA 3R
DESCRIPTION LOAD BREAKER CKT. CKT. BREAKER LOAD DESCRIPTIONkVA POLE TRIP NO. 0 NO. POLE TRIP kVA
ELECTRIC SPACE HEATER 7.5 3 30 1 A 2 3 30 4.8 GATE HOIST NO. 1
� � __,,,- 3 B 4 � � � � � _/ 5 C 6 � � �
GATE HOIST NO. 2 4.8 3 30 7 A 8 3 30 8.6 LIGHTING PANEL
-- -- /' 9 B 10 /' -- --
� � __,,,- 11 C 12 � � �
SPARE - 3 100 13 A 14 3 30 - SPARE
� � __,,,- 15 B 16 � __,,,- � � � _/ 17 C 18 __,,,- � �
PREPARED SPACE - 3 - 19 A 20 3 - - PREPARED SPACE
� � / 21 B 22 __,,,- _/ � -- -- .- 23 C 24 .- / --
PREPARED SPACE - 3 - 25 A 26 3 - - PREPARED SPACE
-- -- .- 27 B 28 -- -- --
� � _/ 29 C 30 __,,,- � �
EUH-1 (OPTIONAL BID ITEM 0004) 10 3 35 31 A 32 3 - - PREPARED SPACE
� � _/ 33 B 34 __,,,- � � � � __,,,- 35 C 36 � __,,,- �
ELECTRONIC CHECK METER - 3 15 37 A 38 3 30 - SURGE PROTECTIVE DEVICE
� � __,,,- 39 B 40 � __,,,- � � � __,,,- 41 C 42 __,,,- � �
12.3 LOAD SUB-TOTALS: kVA 13.4
TOTAL CONNECTED LOAD = 25.70kVA DEMAND LOAD = 17.48kVA DEMAND + 25% SPARE = 21.85kVA
PANELBOARD SCHEDULE - POWER PANEL "LIGHTING PANEL"
FED FROM: GHDP NEUTRAL BUS: 100% TUB: SINGLE
VOLTAGE: 120/208V, 30, 4WIRE GROUND BUS: EQUIPMENT MOUNTING: SURFACE
AMPERE RATING: 100A AIC RA TING: 10,000 LOCATION: GATE HOUSE
MAINS: 100A MLO BUSSING: COPPER ENCLOSURE: NEMA 3R
DESCRIPTION LOAD BREAKER CKT. CKT. BREAKER LOAD DESCRIPTIONkVA POLE TRIP NO. 0 NO. POLE TRIP kVA
OPERA TING FLOOR LIGHTS (XM) 1.6 1 20 1 A 2 1 20 0.5 FLOODLIGHT NO. 1 (XM)
OUTLET AT DESK (XM) 0.2 1 15 3 B 4 1 20 0.5 FLOODLIGHT NO. 2 (XM)
SUB FLOOR LIGHTS (XMl 0.5 1 15 5 C 6 1 20 1.9 HEATERS GATE & PANEL (XM)
EMG. MAIN FLOOR (XM) 0.1 1 15 7 A 8 1 20 1.1 ELECTRICAL OUTLETS (XM)
HATCH FOR ROOF (XM) 0.3 1 15 9 B 10 1 15 0.1 CEILING FAN (XM)
OUTLET ra! RIGHT (XM) 0.2 1 20 11 C 12 1 20 - SPARE
SPARE - 1 20 13 A 14 1 20 - SPARE
SPARE - 1 20 15 B 16 1 20 - SPARE
SPARE - 1 20 17 C 18 1 15 - SPARE
SPARE - 1 15 19 A 20 1 15 - SPARE
PREPARED SPACE - 1 - 21 B 22 1 - - PREPARED SPACE
PREPARED SPACE - 1 - 23 C 24 1 - - PREPARED SPACE
2.7 LOAD SUB-TOTALS: kVA 4.1
TOTAL CONNECTED LOAD = 6.BOkVA DEMAND LOAD = 6.80kVA DEMAND + 25% SPARE = 8.50kVA
PANELBOARD SCHEDULE NOTES:
0 REFER TO ELECTRICAL NEW WORK ONE-LINE DIAGRAM ON SHEET E�01 FOR PROPOSED WIRING.
0 WIRE WITH 2#12 & 1#12 GRD. WITHIN EXISTING CONDUIT TO THE FIRST DEVICE ON THE BRANCH CIRCUIT.
0 OPTIONAL BID ITEM 0004: PROVIDE SURFACE MOUNTED 1" GALVANIZED RIGID STEEL CONDUIT WITH WIRING AS INDICATED ON SHEET E-601 FROM ELECTRICAL CABINET UNIT HEATER TO PANEL "GHDP". REFER TO SHEET E-401 AND SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
US Army Corps of Engineers ® ci w z 0..,. z Cl u.. ·· "'
0 z 0 0wo Ot--
� i;2 0 (!) � � :?:: cl, w <( u ... ;s: w tii
:::, :::, :J z w cnZ 0 0 I (/) <( - -, (/) 0 Cl>- (/) oil w en w
(!) w ...I 0.. ><'. ::::J � :5 <(
1'i '3 :;;_ w- ::c en-ww 0 :::!c:: - ...J
... u.. <( en <( 0::;; Cl
...I I-��� w r:n !:!2 <(w w ... u.. o□ (/) � a'.5w I 0w w !,: ...I (!) w
SHEET ID
E-501 z w Cl
W 2W
J2 4B e6eddjmn
2 3 4 5 6
M
L
K
J
H
G
F
E
D
C
B
A
7 8 9 10
NOTE: THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
LUMINAIRE REQUIREMENTS:
1 . HOUSING - EXTRUDED ALUMINUM OR WELDED STEEL HOUSING WITH SNAP-ON
END CAPS. SIZE AS INDICATED IN LUMINAIRE SCHEDULE.
2. OPTICS - DIFFUSE ACRYLIC LENS.
3. LIGHT SOURCE - SOLID STATE LEDS, 4000K CCT LION, MINIMUM 80 CRI LION, AND
MINIMUM EFFICACY OF 90 LUMENS/WATT LION. 7,000 LUMEN MINIMUM INITIAL
OUTPUT.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DIM MABLE DRIVER WITH
MINIMUM 0.9 PF, OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT,
AND< 20% THD. ON/OFF CONTROL AND FULLY DIMMABLE DOWN TO 10%
MINIMUM OR AS INDICATED IN LUMINAIRE SCHEDULE.
5. CERTIFICATION - UL LISTED FOR DAMP OR WET LOCATION, ROHS COMPLIANT.
DLC QUALIFIED. COMPLIES WITH IES LM79, LM80 AND TM21 TESTING
STANDARDS.
6. MOUNTING - PENDANT, STEM, OR SURFACE MOUNTED WITH STAINLESS STEEL
MOUNTING HARDWARE.
7. OPTIONS - INTEGRAL OCCUPANCY SENSOR, EMERGENCY BATTERY BACK-UP,
VARIOUS PROFILE DIMENSIONS AND RUN LENGTHS, AND VARIOUS CLEAR OR
FROSTED POLYCARBONATE LENSES.
LED INDUSTRIAL LIGHT (OPTIONAL BID ITEM 0003)
REVISED: OCTOBER 2023 LIGHTING PLATE: NL -A
11 12 13 14 15
NOTE: THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF ALUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-CAST ALUMINUM HOUSING WITH CORROSION RESISTANT PAINT
FINISH.
2. OPTICS - FROSTED GLASS DIFFUSER.
3. LIGHT SOURCE - SOLID STATE LEDS, 4000K CCT LION. 600 LUMENS MINIMUM
INITIAL OUTPUT.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DIMMABLE DRIVER WITH
MINIMUM 0.9 PF, OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT,
AND< 20% THD. ON/OFF CONTROL AND DIMMABLE AS INDICATED IN LUMINAIRE
SCHEDULE.
5. CERTIFICATION - UL LISTED FOR WET LOCATION, ROHS COMPLIANT. COMPLIES
WITH IES LM79, LM80 AND TM21 TESTING STANDARDS.
6. MOUNTING - WALL MOUNTED WITH REQUIRED MOUNTING HARDWARE.
7. OPTIONS - CEILING OR WALL MOUNTING.
LED JELLY JAR LUMINAIRE (OPTIONAL BID ITEM 0003)
16 17 18 19 20
I •• - • •
� [ l
,v, LJ � ;/
NOTE: THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-CAST ALUMINUM HOUSING WITH POWDER COAT FINISH.
2. OPTICS - TEMPERED GLASS LENS. BUG RATING AS DETERMINED BY LIGHTING
ZONE INSTALLED.
3. LIGHT SOURCE - SOLID STATE LEDS, 4000K CCT LION, MINIMUM 80 CRI LION, AND
MINIMUM EFFICACY OF 70 LUMENS/WATT LION. 24,210 LUMENS MINIMUM INITIAL
LUMEN OUTPUT.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DIMMABLE DRIVER WITH
MINIMUM 0.9 PF, OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT,
AND< 20% THD. ON-OFF CONTROL AND FULLY DIMMABLE DOWN TO 10%
MINIMUM OR AS INDICATED IN LUMINAIRE SCHEDULE.
5. CERTIFICATION - UL LISTED FOR WET LOCATION, ROHS COMPLIANT. COMPLIES
WITH IES LM79, LM80 AND TM21 TESTING STANDARDS.
6. MOUNTING - SUITABLE FOR PROJECT SPECIFICATIONS.
7. OPTIONS - OPTICAL VISORS, VARIOUS SHAPES AND SIZES, VARIOUS BEAM
ANGLES.
LED FLOOD LUMINAIRE (OPTIONAL BID ITEM 0002)
REVISED: OCTOBER 2023 LIGHTING PLATE: NL -8 REVISED: OCTOBER 20231 LIGHTING PLATE: XL -c
LIGHTING FIXTURE SCHEDULE
FIXTURE LAMPS
TYPE
DESCRIPTION
TYPE
A 4' SURFACE MOUNTED LINEAR LED STRIPLIGHT FIXTURE. LED 43.9W
(OPT. BID
7,000 LUMENS
ITEM
4000K
0003)
LED 15W
B LED WALL MOUNTED VAPORTIGHT JELLY JAR FIXTURE. 600 LUMENS
(OPT. BID 4000K
ITEM
0003)
LED 163W
C LED ADJUSTABLE, SLIPFITTER MOUNTED, HIGH-LUMEN FLOODLIGHT FIXTURE. PROVIDE WITH SPOT (29°) DISTRIBUTION 24,210
(OPT. BID AND TOP-MOUNTED OPTICAL VISOR. LUMENS
ITEM 4000K
0002)
LIGHTING FIXTURE NOTES:
1. FURNISH ALL LIGHTING FIXTURES COMPLETE WITH MOUNTING ACCESSORIES TO MEET JOB REQUIREMENTS. REFER TO SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS NOT SHOWN IN ELECTRICAL LIGHTING FIXTURE SCHEDULE.
VOLTAGE
120-277
120-277
120-277
2. IN ADDITION TO ANY SUBMITTAL REQUIREMENTS STATED IN ELECTRICAL SPECIFICATIONS OF CONTRACT DOCUMENTS, SHOP DRAWINGS AND PRODUCT DATA SUBMITTALS SHALL INCLUDE PHYSICAL DIMENSIONS, PHOTOMETRICS, SPECIFIC LAMP TYPE AND MOUNTING DETAILS.
LIGHTING
PLATE
NL-A
NL-B
XL-C
m US Army Corps of Engineers ®
Cl) LJJ Cl
Cl w
<) '3 ::;;_-wwCl'. - _J r- LL <( u::;;o � ci: � wcc� W r- LL Cl)� 5w
LJJ
Cl z z
0) w Cl LL 0 O () (9 � C0 Z'
:,: LJ/ LU
<( <( LJJ
Cl'. J: :,:: Cl r- Cll c6 w _J
::c (/) (.) _J _J I-<(W (.) 0 er:
w _J w
SHEET ID
E-502
LU
Cl z
LU
Cl
W 2W
J2 4B e6eddjmn
N
M
L
K
J
H
G
F
E
D
C
B
A -
I 2 I
OFFICE DISTRIBUTION PANEL [XM]
400A, 120/20BV, 30, 4W
SPACE SPACE
3 I 4
SPACE
I 5 I 6
NATIONAL GRID OH
PRIMARY FEEDER [XM]
y
400A 400A
SPACE
l I
( l
NATIONAL GRID POLE
MOUNTED UTILITY
TRANSFORMERS [XM]
I l
0/208V
• '-ill
XM
I� #25165800
XM
250A ) SOD
225A I QB225
SPARE
I 7
XM-----�
XM
) 100A 70A
\..E
N � L (l �
250A 200A
XM
I s
20kW/25kVA GENS ET
DIESEL FIRED
120/208V, 30, 60Hz
OFFICE MANUAL
TRANSFER SWITCH
) SOD
QB200
200A MCB,
120/208V, 30,4W
I 9
250A ) SOD
225A
I
QB225
SPARE
I 10 I 11
250A ) SOD
225A I QB225
SPARE
I
250A 200A
) SOD
QB200
XM-.____,
LJ
200A
I
250A 200A
OFFICE
XM 30,4W /
200A MCB,
120/208V, EXISTING SES ------------
XM
SIMPLEX ----
CONTROLLER
#S31016H
100A/40A
1P-30A
,----.... -10�0;;,'00A ----�+-----
0 4#300KCMIL & #2GRD --HD
XM
HANDHOLE NO. 1 EH
UTILITY
BUILDING
XM
125A MLO,
120/208V, 10, 3W
EXISTING SEWER 0 4#300KCMIL & #2GRD
GATE HOUSE DISTRIBUTION PANEL "GHDP"
1 OOA, 120/208V, 30, 4W
100A 15A
(DlcM
100A )30A r
(DlsPDI
100A 30A
3#10 & #10GRD -3/4"C. [RGS] ---El), NEMA3R
3#10 & #10GRD -3/4"C. [RGS]
30AS
INTEGRAL
THERMOSTAT
--+-""'4r T
/VVVV
7.5kW SPACE
HEATER [XM]
PUMP [XM] I
XM
STORAGE
BUILDING
HANDHOLE NO. 2 EH
0 4#300KCMIL & #2GRD D
100A )INCOMING
100A r LINE
100A } 30A
100A 30A
100A 30A
4#10 & #1 OGRD - --f-ll
3/4"C. [RGS]
(I+--- 3#12 & --HD 100A MLO,
XM --
#12GRD 120/208V,
XM
r-0'--, 30,4W
1--CONTROL-
CABINET
LIGHTING
PANEL
13.2 A
GATE HOIST
NO. 2 [XM]
GATE HOIST
NO. 1 [XM]
100A } 35A
,Cl+--.-3#8 & #10GRD -
1"C. [RGS] •
60ASn_J NEMA3Rl,:-J
/EUH\
\1/
[OPTIONAL BID ITEM 0004]
) SOD
QB200
I 14 I
1- EXISTING UNDERGROUND
SPARE CONDUIT
XM
200A MCB,
120/208V, 30,4W
STORAGE
BUILDING
[NOT IN SERVICE]
15 I l�A1�;1- _ E_L_ E_C_T_R_IC_A_ L_N _E_W _ W_ O_R_K_O _N_E_-L_IN_E _D_IA_G_ R_A _M __________________________________________ _
SCALE: N.T.S.
16 I 17 I 1s
NOTES:
I 19 I
1. REFER TO SHEET E-001 FOR LEGEND, SYMBOLS,
ABBREVIATIONS, AND GENERAL NOTES.
2. SPLICES OF EXISTING AND NEW FEEDER CONDUCTORS SHALL
BE COVERED WITH AN INSULATION EQUIVALENT TO THAT OF THE
CONDUCTORS OR WITH AN IDENTIFIED INSULATING DEVICE. ALL
SPLICING MEANS INSTALLED ON CONDUCTORS SHALL BE APPROVED
FOR WET LOCATIONS.
3. CONTRACTOR SHALL FURNISH SHORT-CIRCUIT, PROTECTIVE
DEVICE TIME-CURRENT COORDINATION AND ARC-FLASH STUDY IN
ACCORDANCE WITH UFC 3-501-01. REFER TO SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
------ LINETYPE DENOTES EXISTING EQUIPMENT TO
REMAIN.
------ LINETYPE DENOTES NEW EQUIPMENT
KEYNOTES:
0 ROUTE CONDUCTORS WITHIN EXISTING CONDUIT BELOW
GRADE.
ROUTE CONDUCTORS WITHIN EXISTING 1-1/4"C
EMBEDDED WITHIN GATEHOUSE CONCRETE SLAB.
WIRE IN ACCORDANCE WITH MANUFACTURER
RECOMMENDATIONS.
m US Army Corps of Engineers ® ci w z ci -st z 0 LJ. .. N z 0 0 wo 0 l) ,_ f-- N f--
l) (.')� "'
0 0:: � z' w <(
- en
l) f-- sw w ::J z <( w (/) z 0 0 0:: :f I (/) <( - -, (/) l) 0 f-- (/) w z ii:
l) en w 0
W .
. . ...J Cl) .. >- <( . � >- en ol-:
z►z a::i zoz cnZ 0orooo-w<C-w f-- f-- w "' f-- ::, �$ Z $o,:�t::$ 0 -wSwllo:::::ww··CfJ <( w co ClJ wZo::ZICD
Z�zo--;o--;o---;w7(1)<(
O'.'.
0� s� sr.9 W<( Zo _J w <( z0- -_J O'.'. ' I- w oz wo _J
SHEET ID
E-601
W 2W
J2 4B e6eddjmn
| THA-EB-137_PLANS |
| THA-EB-137_Elec-Upgrades - Electrical Plans_ITR_BCOES_Backcheck |
| THA-EB-137_G-001 |
| THA-EB-137_E-001 |
| THA-EB-137_ED401 |
| THA-EB-137_ED601 |
| THA-EB-137_ES101 |
| Sheets and Views |
| ES101 |
| Sheet 1 |
| THA-EB-137_PLANS |
| THA-EB-137_Elec-Upgrades - Electrical Plans_ITR_BCOES_Backcheck |
| THA-EB-137_E-401 |
| THA-EB-137_E-501 |
| THA-EB-137_E-502 |
| THA-EB-137_E-601 |
| THA-EB-137_Elec-Upgrades - Information Drawings_ITR_BCOES_Backcheck |
| TH-1-19_1 - Sheet 45 - Exterior Electrical Plans and Details |
| TH-1-19_2 - Sheet 46 - Exterior Electrical Intake Structure and Service Bridge |
| TH-1-19_3 - Sheet 47 - Intake Electrical Plans, Sections and Details |
| TH-1-21_2 - Sheet 49 - Utility Building Plumbing, Heating and Electrical |
| 2024-02-14T07:58:47-0500 | |
| MUELLER.KATELYN.ELIZABETH.1159407183 |
| 2024-02-14T11:08:40-0500 | |
| TESSIER.MATTHEW.E.1377053253 |
| Date3_af_date: 2/14/24 | |
| 2024-02-20T07:39:57-0500 | |
| MARGOLIS.DAVID.I.1228573805 |
| Date5_af_date: 2/14/2024 |
| Date6_af_date: 2/20/24 |
File details come from the government source that posted it. Updated .