Attachment B Term Sheet (Sample).pdf

PDF 355 KB Posted

Attached to
Enhanced Use Lease for Commercial Power Generation Facility
Solicitation number
W912-QR-DACA27-1-27-0015900
Issued by

About this file

This document is an Indicative Term Sheet for a commercial power generation facility and/or data center project to be developed on underutilized Army installations under Enhanced Use Lease (EUL) authority pursuant to 10 U.S.C. § 2667, issued as Request for Proposals No. DACA27-1-27-0015900.

The term sheet establishes the foundational commercial and operational framework for the selected company to design, finance, permit, develop, construct, operate, and eventually decommission a power generation facility and/or data center on Army property. The initial lease term is twenty-five (25) years with one optional renewal period, contingent upon performance metrics including no more than two defaults annually and DA's affirmative written consent. Project Consideration comprises Base Rent at fair market value as determined by DA-approved appraisal, Commercial Upside Participation Rent calculated from three revenue streams (gross revenues from power sales, subleased rent from data center tenants, and powered land value capacity adjustments), and In-Kind Consideration (IKC) in the form of installation improvements. The company must provide contingency power within one hour of grid outage for a minimum of fourteen continuous days (preferably up to ninety days), along with utility infrastructure improvements. The company bears responsibility for all environmental compliance, NEPA documentation, permitting, water sourcing from non-potable alternative sources, hazardous materials management, and site decommissioning with financial security maintained through a bond or letter of credit. Critical restrictions include compliance with CMMC cybersecurity requirements, DFARS covered defense information protocols, physical air-gapping of industrial control systems, personnel vetting for military installation access, and prohibitions on engagement with restricted entities (including foreign adversaries, debarred entities, and certain Chinese companies per DOE Order 486.1A). The company must complete FOCI review with no negative findings, achieve specified development milestones on a defined timetable, and maintain comprehensive insurance and decommissioning security. DA retains unilateral authority to suspend facility access for national security or emergency purposes, with the company permitted to terminate the lease without penalty if suspension exceeds 180 consecutive days. Only Section 6 (Expenses, Confidentiality, Non-Binding Nature, Notices, Disputes, Indemnification, and EUL form) is binding; all other provisions are indicative and subject to execution of the definitive EUL.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Indicative Terms and Conditions for Commercial Power Generation Facility and Data Centers at Army Installations

Request for Proposals No. DACA27-1-27-0015900

This summary of indicative terms and conditions (“Term Sheet”) for the transaction outlined below (the “Proposed Transaction”) is for the purpose of facilitating discussion between the Department of the Army and [Insert Company Legal Name], together, the “Parties.” This Term Sheet does not purport to summarize all terms of the definitive documentation needed to memorialize the transaction. Any legal obligations (except for Section 6 herein) shall arise only upon execution and delivery by the Parties of definitive agreements for the proposed transaction.

1. Parties & Project Overview

a. U.S. Government The Department of the Army (the “DA”)

b. Company [Insert Company Legal Name], a [Insert State of Incorporation and Entity Type], or another entity controlled by [Insert Parent/Sponsor Name] (the “Company”)

c. Project As detailed in the Request for Proposals No. DACA27-1-27-0015900 (the “RFP”) incorporated by reference herein, Company will lease approximately [Insert Acreage] acres of underutilized DA land at [Insert Installation] (the “Leased Premises") for the purposes of the Company designing, financing, permitting, developing, constructing, installing, owning, maintaining, operating, securing, and decommissioning a commercial power generation facility [and data center if applicable] (the “Project”).

The indicative provisions of this Term Sheet shall control over the RFP in the event of any conflict, inconsistency, including any expanded, modified, stricter or additional requirements set forth in this Term Sheet.

d. Technology Focus & Limitations [Insert general description of the specific power generation [and data center if applicable] project that was selected]

e. Restricted Entity Company shall not directly or indirectly (a) be owned or controlled by any Restricted Entity, (b) transfer any property (including funds) to any Restricted Entity, or (c) otherwise do business with any Restricted Entity. The Company shall adopt and implement reasonably prudent processes and procedures in order to prohibit transferring any property (including funds) to, or otherwise doing business, with any Restricted Entity. “Restricted Entity” means any Person that is, or is owned or controlled, directly or indirectly, by: (i) a person that is debarred, suspended, or proposed for debarment from doing business with DA or any other federal agency; (ii) a Person then appearing upon the “Denied Persons List,” the “Entity List,” or the “Unverified List,” as maintained by the U.S. Department of Commerce; (iii) a Person on the U.S. Office of Foreign Assets Control “Specially Designated Nationals and Blocked Persons List,” the “Sectoral Sanctions Identifications List,” the “Non- SDN Chinese Military Industrial Complex Companies List,” the “Foreign Sanctions Evaders List,” or any similar list maintained by a Governmental Authority of the United States, including Persons resident in embargoed countries, territories, or regions;

(iv) a “Foreign Entity of Concern” as defined by 15 U.S.C. § 4651(8) or 42 U.S.C. § 18741(a)(5) or a “Foreign Adversary” as defined by 15 CFR § 791.4; (v) the government, including any political subdivision, agency, or instrumentality thereof, or any national, of any country, territory, or region against which the United States maintains comprehensive economic sanctions or embargos from; (vi) The People’s Republic of China or a country determined to be of risk in accordance with U.S. Department of Energy Order DOE O 486.1A(5)(d) (https://www.energy.gov/science/countries-risk); (vii) a Person that the Company knows or reasonably suspects is acting or purporting to act, directly or indirectly, on behalf of, or a Person (wherever organized, in the case of an entity) owned or controlled by, any of the Persons listed in sub-clauses (i)-(iv) above; or (viii) a Person with whom dealings are expressly prohibited on account of any economic sanctions laws, regulations, or directives, of the United States, if the investment in such Person would knowingly cause the Company (or any subsidiary) to be in violation of such laws, regulations, or directives. With respect to any person that is a company with a class of securities registered under the Exchange Act (or subject to a comparable non-U.S. reporting regime), for purposes of this definition of Restricted Party, ownership does not include passive non-controlling beneficial ownership of less than 10% by any single person or any “group” (as defined in Section 13(d)(3) of the Exchange Act and Rule 13d-5 thereunder).

f. FOCI The closing of the Transaction contemplated in this Term Sheet shall be conditioned upon, among other things, the satisfactory completion of the U.S.

Government's foreign ownership, control or influence ("FOCI") review ("FOCI Review") and confirmation that there are no negative findings.

g. Assignment of the Term Sheet Company shall not assign or otherwise transfer this Term Sheet or any of its rights or obligations under it or with respect to the RFP or Company’s Proposal without the prior written consent of the DA (such consent not to be unreasonably withheld, conditioned or delayed). However, in no case shall the Government be required to approve the transfer or assignment of this Term Sheet or any of the Company’s rights or obligations under it or with respect to the RFP or Company’s Proposal to a Non- Qualifying Party or Restricted Entity.

2. Proposed Transaction Structure

a. Leasehold Interest This transaction will be a leasehold interest executed as an Enhanced Use Lease (the “EUL”) under 10 U.S.C. § 2667 and as described in the RFP. The United States shall retain fee simple title to the Leased Premises.

b. Lease Term The initial lease term will be twenty-five (25) years. [Following language contingent on whether selected Offeror proposed a renewal option.] with one (1), [XX] year renewal option, exercisable upon the following conditions: (1) the Company providing written notice of its desire to renew to DA not less than twelve (12) months prior to expiration of the then-current term; (2) the Company has not committed more than two (2) defaults within any year during the term of the EUL; (3) there are no uncured events of material default by Company; and

(4) DA's affirmative written consent to the renewal, at its sole discretion.

c. Development Plan Company shall provide a project plan which shall be submitted to DA for approval and will be attached and incorporated into the EUL (the “Development Plan”), prior to lease execution. Company shall develop the Project in accordance with the Development Plan, which will outline key construction, project phasing where applicable, and operational milestones, and shall incorporate the utility plans identified in this Term Sheet.

d. Milestone Timetable Company included in its Proposal a list of key milestones for the proposed Project (the “Milestone Timetable”) that is attached hereto and made a part hereof. Company will be required to meet the milestones within the timeframes set forth on the Milestone Timetable. Company understands that time is of the essence to the DA in accomplishing the milestones set forth on the Milestone Timetable and in otherwise complying with the Company’s obligations under this Term Sheet. If the Company anticipates an inability in any material respect to meet in a timely manner any milestone contained in the Milestone Timetable, the Company shall promptly so advise the DA in writing. Company and DA agree to enter into good-faith discussions to revise the Milestone Timetable within a reasonable timeframe. A default under this Term Sheet shall arise only in the case of a material breach that remains uncured after reasonable written notice and opportunity to cure.

Company shall not be liable for any failure to perform under this Term Sheet or any delay in performing under it (including any failure to meet a milestone set forth in the Milestone Timetable) if such failure is due directly to any of the following causes or circumstances and such cause or circumstance is beyond the Company’s control (and such event, an event of Force Majeure): war; fire;

riot; terrorist act; flood; or other extreme weather; accident; change (hereafter) in any law or regulation;

regulatory action impeding the Company’s ability to obtain any necessary permits or approvals for its development, once the Company has submitted its application and any supporting documentation or studies;

labor strike or lockout; or failure of the DA to take an action required to be taken by it; supply chain disruption;

utility delay; government shutdown;

newly discovered site conditions;

environmental or cultural resource issues; security requirements; or permitting or environmental review delay. If an event of Force Majeure occurs and the Company is delayed in its performance as a result thereof, Company shall be entitled to an extension of time equal to the period of delay caused by the Force Majeure event, provided that the Company notifies the DA in writing of the event of Force Majeure and the anticipated resultant delay within a reasonable period after the Company becomes aware of the relevant event and its anticipated impact. Upon completion of the event of Force Majeure, the Company must, as soon as reasonably practicable, recommence the performance of its obligations under this Term Sheet.

3. Commercial Terms & Consideration

a. Project Consideration For the purposes of the EUL, the term "Project Consideration" means the sum of the Base Rent, any applicable Commercial Upside Participation Rent, and any In-Kind Consideration (IKC) Installation Improvements (as defined below). Per the RFP, DA's preference is IKC. Such in-kind consideration must include the provision of contingency power in the event of a grid outage, such contingency power to be provided within one

(1) hour of a grid outage and provided for a minimum of fourteen (14) continuous days, and providing any required improvements to DA’s utility infrastructure that may be required to enable the Installation to accept delivery of the contingency power. In-kind consideration may also include improvements to Installation infrastructure to improve resilience and reliability, such as dedicated emergency feeders, black-start generators, microgrid control centers, automated transfer switchgear, and dedicated standby reserve allocations. In-kind consideration could also include other DA needs such as data center computing power and storage, restoration, modernization, or construction of facilities either on the Installation or other DA properties. If necessary, the terms, conditions, and procedures governing the valuation, determination, and payment of IKC or cash shall be set forth in an addendum to the EUL.

Except as otherwise set forth herein, Project Consideration shall accrue and be due and payable at all times, throughout the Lease Term, without offset or abatement.

b. Base Rent The Company shall provide base rent at an annual amount at least equal to the fair market value (FMV) of the leasehold, determined by a DA-approved appraisal (the “Base Rent”). The

Base Rent shall begin to accrue upon commencement of the EUL.

c. Commercial Upside Participation Rent

In addition to the Base Rent, upon the date the Project commences commercial operations, as defined below, Company shall pay DA additional rent based on financial participation (the “Commercial Upside Participation Rent”).

For the purposes of the EUL, "commercial operations" shall mean the sooner of (A) the date on which the Project begins producing energy for sale to the market [address data center operations if Project includes a data center] or (B) 2.5 years following lease execution.

The Commercial Upside Participation Rent shall be calculated and paid to DA on an annual basis and shall be provided in accordance with a schedule to be agreed upon in the EUL.

The following three (3) revenue streams will be utilized to calculate the Commercial Upside Participation Rent:

1.For power generation assets: A gross revenue share derived from all revenues, such as, but not limited to, wholesale energy and capacity and, where regulations allow, behind-the-meter power sales to be co-located commercial entities.

2. For data center assets: A revenue share of subleased rent generated from commercial compute tenants.

3. Powered Land Value Capacity Adjustments:

A percentage revenue-share based upon the execution of tenant subleases, capturing the incremental powered land value spread created across the Installation.

d. IKC Installation Improvements

DA prefers the Company provide Project Consideration in the form of improvements to Installation infrastructure and/or services (collectively, “Installation Improvements”) undertaken at or for the benefit of DA.

Examples of IKC Installation Improvements that may be preferable to DA include, but are not limited to, dedicated emergency feeders, black-start generators, microgrid control centers, automated transfer switchgear, and dedicated standby reserve allocations. IKC could also include compute capability for the Installation [if a data center is proposed].

In constructing IKC Installation Improvements to DA assets, the Lessee shall comply with the Federal requirements, including but not limited to, the Davis-Bacon Act, as amended, 40 U.S.C. § 3141, et seq. and the relevant rules, regulations, and orders of the Secretary of Labor; the Americans with Disabilities Act of 1990, 42 U.S.C. § 12101, et seq., and the Architectural Barriers Act of 1968, 42 U.S.C. § 4151, et seq., as amended; and the Buy American Act, 41 U.S.C. §§ 10a - 10d.

Other statutory limitations for acceptable DA consideration include, but are not limited to, the following:

Any goods, services, or technology from a §1260H-listed entity or an entity under its control as described in Pub. L. 118-31 §805;

Any covered material melted or produced in any covered nation, or any end item that contains a covered material manufactured in any covered nation as listed in 10 U.S.C.

§4872(f); and

As described in 10 U.S.C. § 4873, Company may not use acquired printed circuit boards from a covered nation with the exception of supplies or services below the micro-purchase threshold in 10 U.S.C. §3573 or in products considered a commercial product or commercial service.

Improvements solely for the benefit of the Company or that are necessary for the Company’s Project (e.g., utility improvements, roads, etc.) do not constitute IKC.

e. DA Audit Rights During the Lease Term and until the expiration of three (3) years after expiration, or earlier termination of the EUL, DA shall have the right to access and examine any directly pertinent books, documents, papers, and records of the Company involving transactions related to the EUL, including but not limited to records identified above related to the Commercial Upside Participation Rent. Each Commercial Upside Participation Rent payment shall be accompanied by a certified revenue statement from the Company's Chief Financial Officer (or equivalent) detailing the total Gross Net Revenue generated, subject to DA's audit rights as set forth herein.

4. Utility & Environmental Risk Allocation

a. Energy Resilience & Islanding The following items represent DA requirements for Energy Resilience and Islanding:

1. Project must provide resilient energy capabilities to the Installation to ensure it can maintain operations through islanded operation, automated switching, and the ability to route electricity directly to critical loads while shedding non-critical loads as necessary. DA prefers Installation-wide resilience capability versus meeting critical loads only.

2. Energy resilient solutions shall integrate with existing generation assets and demonstrate black-start capability sufficient to sustain essential Installation functions during utility disruptions in compliance with the RFP which requires power to be restored within one (1) hour of a grid outage and for a duration of at least fourteen (14) continuous days. DA preference is for resilience duration to be in excess of fourteen (14) continuous days and up to ninety (90) continuous days of independent operation to align with the FORTRESS America Initiative.

3. Any assets connected to a DA information network shall comply with applicable Unified Facilities Criteria for cybersecurity of facility-related control systems.

b. Water Sourcing - General To preserve regional water assets, DA requires that the Project use non-potable alternative sources, which may include brackish groundwater, appropriately treated reclaimed municipal wastewater, or treated industrial/agricultural runoff.

As part of the Development Plan, the Company shall develop and provide to DA for approval, a detailed plan for securing requisite water, wastewater, and storm water utilities, which shall detail necessary capacity, proposed utility sources, requisite infrastructure, permit requirements, proposed reliance on Installation infrastructure, and any easements that may be required over DA property (the "Water Sourcing Plan"). Such plan shall identify and address water quality or supply quantity concerns that could impact the Project and/or result from the Project. Company's Water Sourcing Plan shall ensure there is no disruption of current Installation water, wastewater, or stormwater utilities.

Provision of water, wastewater, and stormwater utilities and infrastructure needs for the Project shall be the Company's sole cost and responsibility.

To preserve regional drinking water assets, Company is discouraged from using municipal potable water for industrial processing operations.

Company shall, at its sole expense, source all industrial process water from non-potable alternative sources, which may include brackish groundwater, reclaimed municipal wastewater (graywater), or treated industrial/agricultural runoff, subject to DA approval and regulatory compliance, as required.

Closed-Loop Cooling: Projects that include a data center, thermal generation systems and any associated co-located facilities must utilize closed-loop cooling to minimize water usage.

c. Water Sourcing – Waste Water As part of the “Water Sourcing Plan,” Company will detail its plan to address wastewater, including identification of any disposal sources, volume, requisite infrastructure, proposed reliance on Installation infrastructure, permitting, requirements, required easements, etc.

d. NEPA Responsibility In accordance with the RFP, Company will prepare and submit, at its sole cost, risk, and expense, all National Environmental Policy Act ("NEPA") documentation, and secure Federal, state, and local permits required for development, building, and operation of the Project and additional infrastructure and utilities connected to it, as directed by DA and in accordance with applicable law. DA, as the lead Federal agency, will supervise and independently evaluate any environmental documentation prepared by or on behalf of Company for the purpose of NEPA review of the Project.

Notwithstanding the foregoing, DA shall retain exclusive authority and discretion to determine whether NEPA applies, the appropriate level of NEPA review, the scope of the proposed action, the sequence and manner of review, and the adequacy and outcome of any environmental determination, finding, or decision document.

Subject to and in accordance with applicable law, DA shall complete NEPA review prior to EUL execution.

Company shall take no action that would have an adverse environmental effect or limit the choice of reasonable alternatives prior to NEPA completion.

This prohibition includes, but is not limited to, ground disturbance, construction, and any irreversible or irretrievable commitment of resources.

Company and DA will maintain a single, integrated environmental and permitting schedule; provided, that such schedule shall not limit DA's authority to modify scope, sequencing, or timing as required by law or regulation.

e. Hazardous Materials The Company must obtain written DA approval and demonstrate applicability of an authorized statutory exception, as required by 10 U.S.C. § 2692, prior to storing, treating, or disposing of any toxic or hazardous material on the Leased Premises.

f. Excusable Delays The Development Plan deadlines shall be automatically tolled for “Excusable Delays,” as defined in Attachment C to the RFP and as set forth in this Term Sheet.

g. Environmental Liability At all times during the Term, Company shall, at its sole cost and expense, ensure strict compliance with all applicable Federal, state, and local environmental laws and regulations.

Company shall be solely responsible and liable for all environmental matters arising from its use, occupancy, and operations on the Leased Premises. Company assumes all liability for any property damage, natural resource damages, and public or private claims arising from the release, spill, or discharge of any hazardous materials, pollutants, contaminants, or waste caused by its activities. This includes, without limitation, all activities related to the generation, handling, storage, transportation, treatment, and disposal of all waste generated by the Project, including but not limited to industrial process effluent, solid waste, and any materials defined as hazardous, toxic, or regulated under applicable environmental laws.

Company shall be responsible for mitigation measures that are finally determined by the applicable governmental authority to be required as a direct result of the Project, provided that the nature, scope, timing and cost of such measures have been reasonably identified. If any required mitigation actions significantly and adversely affect the viability of the Project, Company and DA shall consult in good faith regarding potential adjustments to scope, schedule, layout or other relevant terms, and either Party may elect not to proceed and terminate this Term Sheet if such matters cannot be resolved on a mutually acceptable basis. Upon such termination, DA shall neither owe nor pay any fees, costs, expenses or monetary penalties to the Company for any reason(s) regarding or stemming from the RFP, and DA shall, at its discretion, be free to select another Offeror to further pursue the EUL and Project or cancel the entire RFP.

5. Substantive Lease Protections

a. Decommissioning Plan and Security Company shall be required, as a condition precedent to EUL execution and land disturbance activities, to submit a Decommissioning and Site Restoration Plan (the "Decommissioning Plan") that meets DA approval, which shall become part of the EUL. The plan must detail the procedures, timelines, and costs for the complete decommissioning, removal of all Lessee-constructed improvements (including, but not limited to data halls, electrical substations, backup diesel generators, fuel storage tanks, battery energy storage systems, underground conduits, and foundations to a minimum depth of four (4) feet below grade), hazardous materials abatement, and environmental remediation to restore the Properties to a safe, baseline condition acceptable to DA.

Prior to commencing land disturbance activities and/or construction activities, Lessee shall obtain and deliver to DA a Decommissioning Bond (issued by an approved surety listed on Treasury Circular 570), an Irrevocable Standby Letter of Credit (issued by an federally insured financial institution acceptable to the Government), corporate guarantee, or other DA approved financial security instrument (collectively, the “Decommissioning Security”) in an amount calculated by an independent, licensed professional engineer, at Lessee’s sole expense, and approved by DA to cover the full estimated costs of decommissioning the Project and restoring the Property in accordance with the Decommissioning Plan. The Decommissioning security shall be maintained in full force and effect until the decommissioning and site restoration obligations have been inspected and approved by the DA. In the Event of Default, as later defined in the EUL, DA shall have the right to draw upon the Decommissioning Security to complete the work.

The Decommissioning Security amount shall be re-evaluated and adjusted every five (5) years, or upon a triggering event including, but not limited to, site modifications, environmental changes, market inflation, and option periods, whichever occurs first. Estimated scrap, salvage, or equipment resale value shall not be deducted or credited against the required Decommissioning Security amount.

b. Performance Guarantee In accordance with the RFP, DA may require that financial and performance guarantees be provided.

c. Command Authority In accordance with the RFP, Company’s use and occupation of the Leased Premises is subject to the general supervision and approval of the DA Installation Commander and Installation rules and regulations regarding physical access. The EUL will include provisions regarding the DA Installation Commander's authority to suspend facility access, including the following concepts:

Emergency and Security Suspension:

The DA Installation Commander retains unilateral authority to temporarily suspend facility access, order evacuations, or restrict operations solely for critical national security purposes, immediate force protection requirements, or active emergency response scenarios (limited to active shooter situations, natural disasters, hazardous material releases, or heightened force protection conditions.)

Security Non-Compliance: The DA Installation Commander may suspend facility access or operations if Company fails to adhere to the agreed-upon Installation security protocols, physical security guidelines, or personnel vetting requirements, provided (except in active emergency situations) Company is given prompt notice and a reasonable opportunity to cure the security non-compliance.

Limitation of Liability: The U.S.

Government, DA generally, and the DA Installation Commander shall bear no liability for any business interruption costs, lost profits, or consequential damages incurred by Company resulting from suspensions or evacuations ordered in accordance with this section.

Termination for Extended Suspension:

If any suspension of facility access or restriction of operations directed by the DA Installation Commander continues for a period of one hundred eighty (180) or more consecutive days, Company may, upon written notice to DA, elect to terminate the EUL without penalty and without further liability except as provided by applicable law and as otherwise expressly provided in the EUL. For the avoidance of any doubt, Company's restoration responsibilities will survive any EUL termination.

d. Defaults & Remedies The EUL will specify clear events of default. Upon an uncured default, DA retains the right to pursue all remedies as set forth in the EUL and as otherwise available at law or in equity.

See Attachment C to the RFP. For avoidance of doubt, the disputes resolution procedure in the EUL shall set forth a dispute process that provides the right of the Company and DA to seek judicial review in the event of a dispute.

The EUL will likewise specify events of default by DA and corresponding notice and cure rights and remedies available to Lessee, including reasonable prior written notice of any alleged Lessee default and an opportunity to cure within a reasonable period before DA exercises any remedy.

e. Assignments & Project Financing Company/ Lessee may not transfer or assign its interest in the EUL without DA's prior written consent. In accordance with Attachment C to the RFP, Company may mortgage its leasehold interest to secure loans from approved mortgagees. Any mortgagee approved by the Government or successor or assignee of such mortgagee shall be referred to in this Term Sheet as an "Approved Mortgagee." DA shall provide Approved Mortgagees with customary financing protections (including notice and cure rights) as memorialized in a lender recognition agreement. DA consent to assignment shall not be unreasonably withheld, conditioned, or delayed.

The lender recognition agreement shall include (1) rights of Approved Mortgagees to receive notices of defaults and terminations; (2) cure rights applicable to any event of default or termination trigger; (3) accommodation of reasonable financing modifications that do not materially impair DA's interest under the EUL; ( 4) prior written consent of each Approved Mortgagee to any amendment, modification, or voluntary termination by Company of the EUL;

and (5) the right to require that insurance policies maintained under the EUL name each Approved Mortgagee as an additional insured and loss payee. When requested by an Approved Mortgagee, DA shall execute estoppel certificates, subordination and attornment agreements, and any other similar documentation as may reasonably be required by an Approved Mortgagee within thirty (30) business days of

Company providing a complete request package.

Any step-in protections provided by DA shall be subject to applicable federal law, including the Anti- Assignment Act.

The EUL will include certain representations and warranties customary for a transaction of this type, to include the following concepts:

Due Authority and Enforceability:

Company represents and warrants that it is a duly organized, valid existing entity in good standing, with all requisite corporate power and authority to execute, deliver, and perform its obligations under the EUL.

Accuracy of Information: Lessee represents and expressly warrants that all information, financial data (other than forward-looking projections), and technical specifications provided to DA in its proposal and during negotiations are true, accurate, and correct in all material respects.

f. Representations & Warranties The EUL will include certain representations and warranties customary for a transaction of this type, to include the following concepts:

Due Authority and Enforceability:

Company represents and warrants that it is a duly organized, valid existing entity in good standing, with all requisite corporate power and authority to execute, deliver, and perform its obligations under the EUL.

The Proposal and this Term Sheet have been, and any and all amendments, additions, and clarifications thereto and any other documents submitted to the DA in connection with the Proposal or the RFP have been or, if submitted hereafter, will be executed and delivered by a duly authorized representative of the Company. The Company has all requisite corporate or other authority necessary to submit the Proposal and this Term Sheet to the DA, to agree to any amendments, additions, and clarifications made thereto by the Company, and to submit such other documents as the Company has submitted or hereafter submits to the DA in connection with the RFP, the Proposal, or the contemplated transaction, and to be legally bound by the terms and conditions thereof and the RFP.

Accuracy of Information: Company represents and expressly warrants that all information, financial data (other than forward-looking projections), and technical specifications provided to DA in its proposal and during negotiations are true, accurate, and correct in all material respects. Company may correct, clarify, update or supplement its Proposal or related submissions prior to execution of the EUL to reflect additional diligence, third-party studies, regulatory developments, site conditions or other information obtained prior to execution of the EUL.

Company shall have the opportunity to conduct such diligence regarding the Leased Premises as it deems appropriate prior to the execution of the EUL.

Compliance with Laws and Debarment: Company represents and warrants that it is following all applicable Federal, state, and local laws, and is not currently suspended, debarred, or otherwise excluded from contracting with any agency of the U.S. Government.

No Conflicts or Litigation: Company represents and warrants that the execution of the EUL will not violate any existing contract, organizational document, or applicable law, and that there is no pending or threatened legal proceedings that would materially impact its ability to complete the Project.

No Collusion: Company represents and warrants that it has not participated in any collusive, anti-competitive, or anti-trust behavior in connection with its selection or proposal submission for this Project.

Company further warrants that its operations on the Installation will not infringe upon the intellectual property rights of any third party.

FY19 NDAA § 889 Compliance:

Company represents and warrants that it does not use any telecom equipment or services in any of its systems covered by Pub. L. 115-232, § 889.

FY24 NDAA § 154 and FY26 NDAA § 842 Compliance: Company further represents and warrants that the Company (including its contractors, operators, suppliers, and sublessees at all tiers) shall comply with any applicable battery procurement restrictions, for example under Section 154 of the National Defense Authorization Act (NDAA) for Fiscal Year (FY) 2024 (Pub. L. 118-31) and Section 842 of the NDAA for FY 2026 (Pub. L. 119-60; 10 U.S.C. § 4865), and any applicable implementing regulations.

g. Physical Access & Security The EUL will establish strict protocols governing physical access to the Leased Premises and the Installation, to include the following concepts:

Personnel Vetting and Credentialing:

Company acknowledges that access to the DA Installation is a privilege, not a right. All Company employees, contractors, sub-contractors, and visitors must undergo required background checks and comply with the DA's established vetting and credentialing procedures prior to being granted access to the DA Installation.

Physical Perimeter and Segregation:

Consistent with the RFP, Company shall, at its sole expense, design, construct, and maintain appropriate physical security barriers (e.g., fencing, access control points) around the Leased Premises. The design of these barriers must effectively segregate the Project and Company’s operations from the broader military Installation and must be approved by the DA Installation Commander.

Compliance with Access Controls:

Company’s personnel and logistics vehicles shall be subject to standard Installation access controls, including vehicle searches and gate restrictions.

Lessee must strictly adhere to all variations in Force Protection Conditions and acknowledges that access remains subject to the DA Installation Commander’s authorities set forth in Section c. above.

h. Cyber & Data Security The EUL will include comprehensive cybersecurity and data protection requirements commensurate with the strategic nature of energy generation and resilience on a Federal Installation, to include the following concepts:

Cybersecurity Maturity Model Certification (CMMC): Company acknowledges that it must comply with all applicable requirements of the Department of Defense (DoD) Cybersecurity Maturity Model Certification (CMMC) program. Before commercial operations begin, Company must achieve and maintain the specific CMMC level mandated by DA based on the type of information handled and the facility’s integration (if any) with Installation infrastructure.

Protection of Covered Defense Information (CDI): To the extent Company processes, stores, or transmits Covered Defense Information (CDI) or Controlled Unclassified Information (CUI), it must implement safeguarding requirements in strict accordance with DFARS 252.204-7012 (Safeguarding Covered Defense Information and Cyber Incident Reporting) and NIST SP 800- 171.

Industrial Control Systems (ICS) and SCADA Security: Company must implement robust cybersecurity measures to protect its Industrial Control Systems (ICS), Supervisory Control and Data Acquisition (SCADA) systems, and power generation and/or datacenter interfaces. These systems must be physically and logically air-gapped from the Installation’s operational networks, unless otherwise explicitly authorized and secured in accordance with DA regulations.

Federal Information Security Modernization Act (FISMA): Should Company operations require it to operate, manage, or interface directly with a Federal information system on behalf of DA, Company shall comply with all applicable requirements of the Federal Information Security Modernization Act (FISMA) and associated Federal policies.

i. Intellectual Property (IP) Protections The EUL will establish the rights, disclosures, and protections regarding Intellectual Property (IP) utilized at the facility, to include the following concepts:

Upfront Disclosure of Core IP: Prior to the execution of the EUL or as a condition precedent to the EUL, Company shall identify and disclose to DA any proprietary technologies, patents, trade secrets, or specialized software (including proprietary generation techniques or Industrial Control Systems) that are necessary for operation of the Project taking place on the Leased Premises;

provided, that Company possesses and owns the Necessary IP, and Company is prohibited (pursuant to confidentiality obligations) from sharing the necessary IP with DA.

Third-Party Licensed IP Carve-Out:

The disclosure obligation above shall not require Company to disclose IP that is owned by and licensed from a third party to the extent such disclosure would breach Company's confidentiality obligations to such third-party licensor; provided, that Lessee shall identify the existence and general subject matter of any such third-partylicensed IP and shall use commercially reasonable efforts to obtain consent from the applicable licensor for disclosure to DA to the extent required for DA's compliance verification purposes. In lieu of disclosing full technical detail of Core IP, Company may elect to provide DA a redacted technical summary sufficient to demonstrate compliance and safety, subject to a mutually agreed non-disclosure agreement; DA retains the right to request additional detail if the summary is insufficient for its verification or national security purposes.

Ownership and Right to Use:

Company represents and warrants that it holds full legal title to,or possesses valid and enforceable commercial licenses for all IP required to construct, operate, and maintain the Project. Company further warrants that its operations at the Installation will not knowingly infringe on any third-party intellectual property rights.

Operational Data vs. Proprietary IP:

While Company shall retain all rights, title, and interest in its pre-existing and independently developed proprietary IP, DA shall be granted unlimited rights to all general operational data, environmental monitoring metrics, and facility output reports necessary for DA to verify lease compliance, calculate "Commercial Upside Participation Rent," and ensure Installation treat as Company’s confidential and proprietary information subject to Section 6.c.

Indemnification for IP Infringement:

Company shall defend, indemnify, and hold the U.S. Government harmless against any third-party claims, liabilities, or business interruptions arising from allegations of patent, copyright, or trade secret infringement related to Company’s operations on the Leased Premises.

6. Binding Provisions

a. Governing Law This Term Sheet shall be governed by and construed in accordance with applicable Federal, state, and local laws and regulations.

b. Expenses Except as provided in this Section 6.b, DA and Company shall pay their own expenses, unless explicitly stated elsewhere in a binding transaction document.

Per Section 8.e of the RFP or any other provision of the RFP, any obligation of Company to reimburse DA for administrative expenses shall arise only after execution of this Term Sheet and shall apply solely to expenses incurred by DA on or after such date. For activities conducted prior to execution of the EUL, the aggregate amount of administrative expenses for which DA may seek reimbursement from Company shall not exceed $[dollar amount].

c. Confidentiality DA and Company acknowledge and agree to the following concepts regarding the confidentiality of this Term Sheet and associated Project data:

FOIA Exemption and Proprietary Data:

Both DA and Company acknowledge that this Term Sheet, along with any subsequent detailed proposals, financial models, and technical specifications, may contain proprietary commercial and financial information.

This Term Sheet and related information are subject to 5 U.S.C. § 552, the Freedom of Information Act (FOIA), and Department of War’s FOIA regulations found at Title 32, CFR, Part 286, and may be publicly releasable, except as exempt from release under the FOIA exemptions identified in 5 U.S.C. § 552(b).

Authorized Government Disclosures and Oversight Carve-outs:

Notwithstanding the above subsection, Company acknowledges that DA may disclose this Term Sheet and associated project information to other Federal entities with a legitimate "need-to-know" for national security or oversight purposes. Such authorized disclosures include, but are not limited to:

Congressional Oversight Committees (including defense and appropriations committees of the House of Representatives and the Senate);

The National Security Council (NSC);

and

Other Federal partner agencies involved in energy resilience and security reviews (e.g., Department of Energy).

Notice of Intended Disclosure: Should a FOIA request be received for records containing Company’s proprietary information, DA shall promptly notify Company in writing.

DA shall afford Company an opportunity to object to the disclosure, submit a detailed substantiation of its proprietary claims, or seek appropriate protective or injunctive relief before any disclosure is made.

Consistent with DA’s FOIA Regulations, the final determination whether to release information shall, after appropriate consultation with Company, be DA’s. DA is not liable for the disclosure or use of any unmarked information and may use or disclose such information for any purpose as authorized by law.

d. Non-Binding Nature Except for this Section 6, this Term Sheet is a non-binding agreement between DA and Company. Nothing in this Term Sheet, including the Parties' execution hereof, shall be construed as approval of, or a commitment to enter into the Proposed Transaction, the EUL or any other definitive agreement, which remains subject to each Party's internal review, approval, and authorization processes. Any other binding obligations must arise expressly upon execution of the EUL.

To the extent not inconsistent with the EUL, the provisions of this Section 6 shall survive the execution of the EUL, and in the event of any termination of negotiations or withdrawal by either Party prior to execution of the EUL, the provisions of Section 6(b)

(Expenses), Section 6(c) (Confidentiality), and this Section 6(d) (Non-Binding Nature) shall survive such termination.

e. Notices Any and all notices, demands, requests and other communications given or delivered under or by reason of or in connection with the provisions of this Term Sheet shall be in writing, and shall be given by certified or registered mail, postage prepaid, by delivery by hand or by nationally recognized air courier service, or by e-mail directed, in the case of the Company, to the address or e-mail set forth below and, in the case of the DA, to the address or e-mail set forth below:

Company:

Department of the Army:

Headquarters, US Army Corps of Engineers CEMP-CR, 3F35 441 G Street, NW Washington, DC 20314-1000

Notices shall become effective when received (or refused) by the addressee, provided that any notice or communication that is received (or refused) other than during regular business hours of the recipient on a business day shall be deemed to have been given at the opening of business on the next business day. From time to time, either Party may designate a new address or e-mail for purposes of notice hereunder to such effect to the other Party. Email notice shall be effective upon confirmation of transmission, and either Party may update its notice details by written notice (including by email) to the other Party.

f. Disputes The Parties shall first seek to resolve any dispute arising under or relating to this Term Sheet through good-faith discussions between senior representatives. If the dispute is not resolved within a reasonable period, either Party may pursue any rights or remedies available under applicable law or as otherwise agreed by the Parties.

g. Indemnification Company shall indemnify the DA and the United States only with respect to third-party claims to the extent arising directly from Company's gross negligence, willful misconduct or material breach of this Term Sheet in connection with activities conducted by the Company on the Installation or Leased Premises pursuant to authorized access. Such indemnity shall not extend to pre-existing site conditions, DA-provided information, or DA's internal enforcement or administrative costs, except to the extent finally awarded in connection with an adjudicated breach by the Company.

h. Form of EUL to be Executed It is understood and agreed upon by the Company that DA is not obligated, and may not have the authority, to agree to any substantive change to the form of the EUL or any other transaction documents included as part of the RFP or the structure of any transaction contemplated thereby;

provided, however, that the Parties may agree upon such project-specific or administrative revisions as may be necessary to reflect final site description, entity name, agreed milestone timing, notice details, and financing or implementation mechanics that do not materially alter the substantive risk allocation contemplated by the RFP.

Execution & Signatures IN WITNESS WHEREOF, the Parties have executed this Term Sheet which shall be effective immediately on the last date signed.

DEPARTMENT OF THE ARMY [Company]

By: ___________________________ By: ___________________________

Name: Name:

Title: Title:

Date:______________________ Date: __________________________

1. Parties & Project Overview
2. Proposed Transaction Structure
3. Commercial Terms & Consideration
4. Utility & Environmental Risk Allocation
5. Substantive Lease Protections
6. Binding Provisions
Execution & Signatures