W912QR-51061297_CORRFinal_Plans-0004.pdf
PDF 4 MB Posted
- Solicitation number
- W912QR-51061297
About this file
These are architectural and engineering design drawings for an Addition/Repair Reserve Component Medical Training Facility (Project No. FTFA20CB09) at Eglin Air Force Base, prepared by the US Army Corps of Engineers Louisville District. The comprehensive set of plans includes detailed schematics for demolition, electrical systems, site details, framing, roof configurations, penetration details, panel schedules, and furniture layouts for a medical training facility.
The drawings provide technical specifications for a renovation project, covering elements such as electrical power distribution (with panel schedules for PP-C and PP-MC), site lighting details, roof system modifications, wall penetration requirements, and furniture placement. The plans are marked "FOR BIDDING ONLY - NOT FOR CONSTRUCTION" and were revised in accordance with Amendment 0004 dated 06/02/2025, indicating an ongoing design refinement process. The project involves precise architectural and engineering specifications for upgrading an existing medical training facility, with careful attention to electrical, structural, and spatial design requirements.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VESTIBULE
CORRIDOR
COMMANDER'S
OFFICE EXAM
DENTAL EXAM
EMERGENCY /
IMMUNIZATION
MED ADMIN
SUPERVISOR
TRAINING
OFFICE
CHIEF NURSE
MECHANICAL
ELECTRICAL
K13K13
A
A
A13
K13
15 14 16
FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND,
AND ABBREVIATIONS REFER TO SHEET A-001.
EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED,
SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO
REMAIN THE OWNER’S PROPERTY, DEMOLISHED MATERIALS
BECOME THE CONTRACTOR’S PROPERTY AND MUST BE
REMOVED FROM THE SITE WITH FURTHER DISPOSITION AT THE
CONTRACTOR’S OPTION.
IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE
ENCOUNTERED IN THE WORK. IF MATERIALS SUSPECTED OF
CONTAINING HAZARDOUS MATERIALS ARE ENCOUNTERED, DO
NOT DISTURB; IMMEDIATELY NOTIFY CONTRACTING OFFICER.
FURNITURE WILL BE REMOVED OR RELOCATED BY THE OWNER
AS NECESSARY PRIOR TO THE DEMOLITION WORK OF THIS
PROJECT.
CARE SHOULD BE MADE TO KEEP DUST AND NOISE FROM
DEMOLITION ACTIVITIES FROM THE OTHER PORTIONS OF THE
BUILDING. ERECT AND MAINTAIN DUSTPROOF PARTITIONS.
COVER AND PROTECT FURNITURE, FURNISHINGS AND
EQUIPMENT THAT HAVE NOT BEEN REMOVED.
PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION
REQUIRED TO PREVENT INJURY TO PEOPLE AND DAMAGE TO
ADJACENT BUILDING AREAS TO REMAIN.
NEATLY CUT OPENINGS AND HOLES PLUMB, SQUARE AND TRUE
TO DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST
LIKELY TO DAMAGE ADJOINING CONSTRUCTION TO REMAIN.
AT LOCATIONS WHERE FLOORING IS TO BE DEMOLISHED,
FLOOR MUST BE FREE OF DUST, DIRT, OIL, GREASE, PAINT,
WAX OR ANY DEBRIS THAT COULD AFFECT INSTALLATION OF
NEW FLOORING.
DRYWALL PARTITIONS: REMOVE GYPSUM BOARD, STEEL
FRAMING, RUNNERS, TRACKS, ANCHORS AND FASTENERS,
UNLESS OTHERWISE NOTED OR SHOWN. PATCH ANCHOR
HOLES WHERE CEILING, WALLS, AND FLOORS ARE TO REMAIN.
1.
2.
3.
4.
5.
6.
7.
8.
9.
GENERAL SHEET NOTES
SHEET KEYNOTES
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S L O
U
IS
V
IL
L E
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L S
T E
L O
U
IS
V
IL
L E
K
Y
A N
S I D
A D
D R
E P
A
IR
R E
S E
R V
E C
O M
P O
N E
N T
M E
D
IC
A L
T R
A
IN
IN
G
F A
C
IL
IT
Y
B
P
O J N
O F
T F
A C
B
P
A U
G U
S T
V B
R E
D
IC
K A
S
C O
R R
E C
T E
D F
IN
A
L S
U B
M
IT
T
FOR BIDDING
ONLY
NOT FOR
CONSTRUCTIONPLAN NORTH
P R
O J E
C T
N O
F
T F
A C
B
P
AD101
O V
E R
A L L D
E M
O L
IT
IO
N
P L A
N
C W
E
IS
B E
R G
B R
IC
H
A R
D S
O N
L S
U N
D E
R L A
N D
SCALE: 1/8" = 1'-0"A1
OVERALL EXISTING AND DEMO PLAN
0 4' 8' 16'
1 DEMOLISH WINDOWS AND INTERIOR SILLS; REPARE
FOR INTERIOR WALL. PATCH AND REPAIR TO MATCH
ADJACENT MATERIAL, COLOR, AND FINISH.
2 DEMOLISH EXISTING SINK AND CABINETRY
3 DEMOLISH EXISTING HALF WALL PARTITION AND
ASSOCIATED TRIM AND FINISHES.
6 DEMOLISH PORTION OF EXISTING GYPSUM METAL
STUD INTERIOR WALL AND PREPARE OPENING FOR
INSTALLATION OF NEW DOOR. PATCH AND REPAIR
AROUND OPENING TO MATCH ADJACENT MATERIAL,
COLOR, AND FINISH. RE: SHEET A-101 FOR OPENING
DIMENSIONS.
8 DEMOLISH EXISTING FLOOR FINISHES AND
ASSOCIATED TRIM.
9 DEMOLISH EXISTING CEILING GRID SYSTEM AND
ASSOCIATED TRIM.
11 DEMOLISH EXISTING WALL TO INSTALL NEW
PLUMBING LINES.
12 REMOVE AND SALVAGE EXISTING EXTERIOR SIGNAGE.
13 DEMOLISH EXISTING VENEER, INSULATION, AND
VAPOR BARRIER.
14 DEMOLISH EXISTING SOFFIT AND METAL PANEL
ABOVE.
15 DEMOLISH PREFINISHED METAL DOWNSPOUT WITH
PRECAST CONCRETE SPLASHBLOCK
16 DEMOLISH EXISTING PREFINISHED GUTTER.
17 DEMOLISH EXISTING EXTERIOR WALL.
18 DEMOLISH PORTION OF EXISTING EXTERIOR WALL
AND PREPARE OPENING FOR INSTALLATION OF NEW
LOUVER. PATCH AND REPAIR AROUND OPENING TO
MATCH ADJACENT MATERIAL, COLOR, AND FINISH. RE:
SHEET A-601 FOR OPENING DIMENSIONS.
NTSSCALE:A13
PHOTO 2
NTSSCALE:K13
PHOTO 1
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/0
/2
W
2Q R
-5
7_ C
O R
R Fi na l_
Pl an s-
GYP BD OVER METAL
STUDS - RE: PARTITION TYPE
PRESS PUTTY INTO THE
PERIMETER BETWEEN
OUTLET BOX AND THE STUD
OR GYP BOARD ALL AROUND
SEAL ALL "KNOCK-OUT"
HOLES CONTAINING WIRE
OR CONDUIT PUTTY
1/8" THICK MOLDABLE
FIRESTOPPING OR
ACOUSTICALLY RATED
PUTTY OR SEALANT
COVERING ALL EXPOSED
SURFACES OF OUTLET BOX
METALLIC OUTLET
BOX SIZE UP TO
"4S"
CABLE BUNDLE,
RE: ELEC DWGS FOR
LOCATIONS AND SIZES
STEEL SLEEVE, OPTIONAL
PACK WITH FIRE
SAFING INSULATION
FIRESTOP
SEALANT, BOTH
SIDES
FIRESTOP SEALANT OR
PUTTY, BOTH SIDES
GYP BD OVER METAL
STUDS - RE: PARTITION
TYPE
EQUAL TO UL SYSTEM NUMBER W-
L-3065; TYP CABLE BUNDLE
PENETRATING GYP BD WALL.
PENETRATION CONSTRUCTION SHALL
COMPLY W/ ALL UL REQUIREMENTS
'1
/2
M A
X
CORNER BEAD, TYP
METAL STUD FRAMING AT
OPENING
3 OR 4 LAYER GYPSUM
BOARD WALL
SLEEVE INSTALLED IN
WALL WITH ACOUSTICAL
SEALANT CONTINUOUS
AROUND SLEEVE
PIPE OR CONDUIT IN SLEEVE
STUFF URETHANE ROD
STOCK AROUND
PENETRATING MEMBER AND
SEAL INSIDE SLEEVE WITH
ACOUSTICAL SEALANT
MINERAL WOOL
INSULATION IN ALL VOIDS
1'
M E
C H
A N
IC
A
L D
U C
S E
E M
E C
H D
W G
F
O R
S
IZ
E
L 2 x 2 x 16 GA. MIN.
STEEL ANGLE ON BOTH
SIDES OF GYP. BOARD
WALL
CONTINUOUS SEALANT
W/ BACKER ROD AT
PERIMETER BOTH SIDES
5/8" GYP. BOARD ON
EACH SIDE OF 6" OR
3 5/8" METAL STUDS
@ 16" O.C.
TYPICAL DUCT PENETRATING
GYP. BOARD WALL - NON-
RATED
5/8" GYP. BOARD ON
EACH SIDE OF METAL
STUDS @ 16" O.C.
MECHANICAL PIPE OR
ELEC. CONDUIT - SEE
MECH. AND ELEC.
DRAWINGS FOR
LOCATIONS AND SIZES
TYPICAL PIPE OR CONDUIT
PENETRATING GYP. BOARD WALL -
NON-RATED
URETHANE
JOINT FILLER
STD. WT. PIPE OR 3/16"
FORMED PL. SLEEVE
(GROUT OR CAST IN
PLACE)
SECTION
FIRE EXTINGUISHER
CONTINUOUS BEAD
SEALANT, TYP
1 1/2"
BLOCKING AS REQ'D,
TYP
2-HORIZ METAL
STUD AS REQ'D,
TYP
FIRE EXTINGUISHER
CONTINUOUS BEAD
SEALANT, TYP
M A
X
/2
ADDITIONAL STUD
FOR BLOCKING
PLAN
PARTITION AS SCHED
RECESSED PULL TYP.
/4
RECESSED
PULL TYP.
RECESSED
PACK VOID W/ FIRE
SAFING INSULATION
FIRE SEALANT W/
BACKER ROD AT
PERIMETER, BOTH SIDES
FIRESTOP SEALANT ALL
AROUND BOTH SIDES
5/8" GYP. BOARD ON EACH
SIDE OF 6" OR 3 5/8"
METAL STUDS @ 16" O.C.
MECHANICAL PIPE OR
ELEC. CONDUIT -
SEE MECH. AND ELEC.
DRAWINGS FOR
LOCATIONS AND SIZES
STANDARD WEIGHT PIPE
OR 6 (1/4") THICK
FORMED PLATE SLEEVE
EQUAL TO UL SYSTEM NUMBER W-L-1003 TYP. PIPE OR CONDUIT
PENETRATING GYP. BOARD WALL WITH SLEEVE
F RATING - 1 HOUR
1 1/2" MIN
M
IN
/4
FIRE SAFING
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S L O
U
IS
V
IL
L E
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L S
T E
L O
U
IS
V
IL
L E
K
Y
A N
S I D
A D
D R
E P
A
IR
R E
S E
R V
E C
O M
P O
N E
N T
M E
D
IC
A
IN
IN
G
F A
C
IL
IT
Y
B
O J N
O F
T F
A C
B
P
A U
G U
S T
V B
R E
D
IC
K A
S
C O
R R
E C
T E
D F
IN
A
L S
U B
M
IT
T
NOT FOR
CONSTRUCTION
P R
O J E
C T
N O
F
T F
A C
B
P
A-522
P E
N E
T R
A T
IO
N
D E
T A
IL
S
C W
E
IS
B E
R G
B R
IC
H
A R
D S
O N
L S
U N
D E
R L A
N D
NTSSCALE:A8
PENETRATION DETAIL
NTSSCALE:A14
PENETRATION DETAIL
NTSSCALE:F8
PENETRATION DETAIL
NTSSCALE:F3
PENETRATION DETAIL
NTSSCALE:A3
PENETRATION DETAIL
SCALE: 1 1/2" = 1'-0"F14
RECESSED FIRE EXTINGUISHER CABINET
0 1/2' 1' 1 1/2'
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/0
/2
NTSSCALE:K8
PENETRATION DETAIL
W
2Q R
-5
7_ C
O R
R Fi na l_
Pl an s-
RIDGE CAP
STANDING SEAM
MTL ROOF
1 1/2" GALV ROOF DECK
COLD FORM MTL FRAMING TRUSS,
RE: STRUCTURE
EXISTING ROOF ASSEMBLY
CLOSED CELL SPRAY FOAM
INSULATION R-28 MIN.
4"
SELF ADHERED UNDERLAYMENT AS ROOF AIR BARRIER OVER
1/2" GLASS MAT GYPSUM ROOF BOARD
10" RIGID INSLUATION (R-32 MIN)
1/2" GLASS MAT GYPSUM ROOF BOARD OVER METAL DECKING
CONT BENT 1/4" X 1'-0" STL PL -
GALV. ATTACH TO ROOF DECK
4" COMPRESSIBLE EXPANSION
JOINT FULLY SEALED INTO
ADJACENT ROOF MEMBRANE
AIR BARRIER
EXPANSION JOINT FLASHING
PANEL CLIP
BEARING PLATE PER ROOF INSTALLER
CONTINUOUS CLEAT
RIVET
FIELD PAN PANEL ENDS AS REQUIRED
WEBBED MASTIC
FOAM AND METAL CLOSURE
RIDGE CAP
1 1/2" GALV ROOF
DECK
MYLAR COATED TAPE
COLD FORM MTL
FRAMING ROOF TRUSS
RE: STRUCTURE
STANDING SEAM
MTL ROOFING SELF ADHERED UNDERLAYMENT AS
ROOF AIR BARRIER OVER 1/2"
GLASS MAT GYPSUM ROOF BOARD
RIGID INSLUATION (R-32 MIN)
1/2" GLASS MAT GYPSUM ROOF
BOARD OVER METAL DECKING
STANDING SEAM MTL ROOF
COLD FORM MTL FRAMING
TRUSS, RE: STRUCTURE
PRE-FINISHED METAL SOFFIT
MATCH EXISTING
PRE-FINISHED STANDING
SEAM METAL FASCIA
MATCH EXISTING
PRE-FINISHED
GUTTER AND
DOWNSPOUT MATCH
EXISTING
CONT BENT 1/4" X 1'-0"
STL PL -GALV. ATTACH
TO ROOF DECK
SELF ADHERED UNDERLAYMENT AS
ROOF AIR BARRIER OVER 1/2"
GLASS MAT GYPSUM ROOF BOARD
6" RIGID INSLUATION (R-32 MIN)
1/2" GLASS MAT GYPSUM ROOF
BOARD OVER 1 1/2" GALV ROOF
DECK
PRE-TREATED
WOOD BLOCKING
EXTERIOR GYPSUM
SHEATHING
PRE-FINISHED METAL
DRIP EDGE MATCH
EXISTING
PRE-FINISHED SOFFIT VENT
MATCH EXISTING
SEALANT
STANDING SEAM METAL ROOF
EXISTING ROOF ASSEMBLY
WITH 1 1/2" RIGID INSULATION
PRE-FINISHED METAL SOFFIT
MATCH EXISTING
CLOSED CELL SPRAY FOAM INSULATION R-27 MIN.
PRE-FINISHED GUTTER AND
DOWNSPOUT MATCH EXISTING
PRE-FINISHED STANDING SEAM
METAL FASCIA, MATCH EXISTING
SELF ADHERED UNDERLAMENT AS AIR BARRIER
EXISTING STRUCTURE
PRE-FINISHED SOFFIT
VENT, MATCH EXISTING
SEALANT
PRE-FINISHED DRIP
EDGE, MATCH EXISTING
PRE-FINISHED DRIP
EDGE, MATCH EXISTING
5/8" MOISTURE
RESISTANT
GYPSUM BOARD
4" METAL STUD
FRAMING , USE
EXISTING FRAMING
WHERE POSSIBLE
EXISTING METAL
STUD FRAMING
1" RIGID
INSULATION
5/8" EXTERIOR
GYPSUM BOARD
COLD-FORMED
METAL STUD WALL W/
MINERAL WOOL BATT
INSULATION (R-19
MIN)
TOP OF SOFFIT
113' - 0"
ALUMINUM
STOREFRONT SYSTEM
PRE-MANUFACTURED METAL CANOPY
W/ LIGHT FIXTURE, 4' - 0" x 9' - 0".
5/8" MOISTURE
RESISTANT GYPSUM
WALLBOARD
COLD-FORMED METAL STUD WALL
W/ MINERAL WOOL BATT
INSULATION (R-19 MIN)
CONTINUOUS FLUID-APPLIED AIR
BARRIER, PROVIDE SELF-
ADHERED AIR BARRIER AT WALL
TRANSITION
1" AIR SPACE
1" RIGID INSULATION (R-6 MIN)
BRICK VENEER
CLOSED CELL SPRAY FOAM
INSULATION, R-27 MIN.
EXISTING METAL STUD WALL
THRU-WALL METAL FLASHING AND DRIP EDGE
ABOVE AND BELOW CANOPY
THRU-WALL METAL
FLASHING AND DRIP
EDGE ABOVE AND
BELOW CANOPY
OUTRIGGER AND STEEL PLATE; RE: STRUCT.
CONT. PLATE; RE:
STRUCT.
HSS; RE: STRUCT.
PROVIDE SELF
ADHERED
MEMBRANE AIR
BARRIER
TRANSITION FROM
FLUID APPLIED AIR
BARRIER TO THRU-
WALL FLASHING
PROVIDE SELF ADHERED MEMBRANE
AIR BARRIER TRANSITION FROM FLUID
APPLIED AIR BARRIER TO THRU-WALL
FLASHING
COUNTER FLASHING WITH SEALANT
FLASHING WITH CONT. TEMINATION
BAR.
HSS; RE: STRUCT.
OUTRIGGER AND STEEL
PLATE; RE: STRUCT.
4' - 0"
EXPANSION JOINT COVER
SELF ADHERED UNDERLAYMENT
AS ROOF AIR BARRIER
STANDING SEAM METAL ROOF
EXISTING STANDING SEAM METAL ROOF
1" RIGID INSULATION
CONTINUOUS FLUID-
APPLIED AIR BARRIER
STANDING SEAM METAL ROOF
SELF ADHERED UNDERLAYMENT AS
ROOF AIR BARRIER OVER 1/2"
GLASS MAT GYPSUM ROOF BOARD
2" AIRSPACE
PRE-FINSIHED METAL FASCIA
CONTINUOUS CLEAT
CONT BENT 1/4" X 1'-0" STL
PL - GALV. ATTACH TO ROOF DECK
RIGID INSLUATION (R-32 MIN)
1/2" GLASS MAT GYPSUM ROOF
BOARD OVER METAL DECKING
SELF ADHERED MEMBRANE AIR BARRIER
TRANSISTION, MIN 4" LAP OVER
ADJOINING AIR BARRIER MATERIAL
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S L O
U
IS
V
IL
L E
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L S
T E
L O
U
IS
V
IL
L E
K
Y
A N
S I D
A D
D R
E P
A
IR
R E
S E
R V
E C
O M
P O
N E
N T
M E
D
IC
A
IN
IN
G
F A
C
IL
IT
Y
B
O J N
O F
T F
A C
B
P
A U
G U
S T
V B
R E
D
IC
K A
S
C O
R R
E C
T E
D F
IN
A
L S
U B
M
IT
T
NOT FOR
CONSTRUCTION
P R
O J E
C T
N O
F
T F
A C
B
P
A-571
R O
O F
D E
T A
IL
S
C W
E
IS
B E
R G
B R
IC
H
A R
D S
O N
L S
U N
D E
R L A
N D
SCALE: 1" = 1'-0"A1
RIDGE DETAIL
SCALE: 1 1/2" = 1'-0"G1
RIDGE CAP DETAIL
SCALE: 1" = 1'-0"G8
EAVE DETAIL
0 1/2' 1' 1 1/2' 0 1/2' 1' 2'
SCALE: 1" = 1'-0"A8
EAVE DETAIL AT EXISTING ROOF
SCALE: 1" = 1'-0"G16
CANOPY DETAIL
0 1/2' 1' 2'
0 1/2' 1' 2' 0 1/2' 1' 2'
SCALE: 1 1/2" = 1'-0"A16
ROOF EXANSION JOINT DETAIL
0 1/2' 1' 2'
SCALE: 1 1/2" = 1'-0"L1
ROOF RAKE DETAIL
0 1/2' 1' 1 1/2'
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/0
/2
W
2Q R
-5
7_ C
O R
R Fi na l_
Pl an s-
EXISTING
ROOF DECK
METAL
STUD WALL
PER ARCH
BRICK VENEER
PER ARCH
EXISTING STL
BM
KICKER AND
CONNECTION TO
RESIST WALL WIND
FORCE AT EACH
EXISTING JOIST PER
CFS DESIGNER
EXISTING
STL JOIST
MIN 45°
METAL STUD WALL
PER CFS DESIGNER
STEEL
ROOF DECK
12 GA BENT PL
ATTACHED w/ #12
SCREWS @ 6"
12"
12"
GRID
METAL STUD WALL
PER CFS DESIGNER
EXISTING
ROOF DECK
GRID
KICKER AND
CONNECTION TO
RESIST WALL WIND
FORCE AT EACH
EXISTING JOIST
PER CFS DESIGNER
EXISTING STL BM
EXISTING
STL JOIST
EXISTING
WALL AND
VENEER
STEEL ROOF
DECK
METAL STUD WALL
PER CFS DESIGNER
12 GA BENT PL ATTACHED
w/ #12 SCREWS @ 6"
12"
12"
EXP JT.
SEE ARCH
STEEL ROOF
DECK
EXISTING STEEL BM
EXISTING STEEL JOIST
CFS TRUSS
PER CFS
DESIGNER
EXP JT.
SEE ARCH
1/4" BENT
PL, CONT
12"
12"
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S L O
U
IS
V
IL
L E
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L S
T E
L O
U
IS
V
IL
L E
K
Y
A N
S I D
A D
D R
E P
A
IR
R E
S E
R V
E C
O M
P O
N E
N T
M E
D
IC
A
IN
IN
G
F A
C
IL
IT
Y
B
O J N
O F
T F
A C
B
P
A U
G U
S T
V B
R E
D
IC
K A
S
C O
R R
E C
T E
D F
IN
A
L S
U B
M
IT
T
NOT FOR
CONSTRUCTION
P R
O J E
C T
N O
F
T F
A C
B
P
S-514
F R
A M
IN
G
D E
T A
IL
S
P G
R O
S S
K A
M P
H Z
E L L E
R
J S
C H
M
ID
T
SCALE: 3/4" = 1'-0"
B13
SECTION
SCALE: 1" = 1'-0"
B7
SECTION
0 1/2' 1' 2' 0 1' 2' 3'
SCALE: 3/4" = 1'-0"
F7
SECTION
SCALE: 3/4" = 1'-0"
K7
SECTION
0 1' 2' 3'
0 1' 2' 3'
SCALE: 1" = 1'-0"
H13
SECTION
0 1/2' 1' 2'
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/0
/2
W
2Q R
-5
7_ C
O R
R Fi na l_
Pl an s-
J
J
PP-MC PP-C
WALL MTD
IMM. UPS
EXISTING
PANEL LA
ELECTRICAL
TIME
CLOCK
WITH
CONTACTOR
DSHP-02
PP-MC-17,19
D30
PP-C-39
DSFCU-02
PP-MC-12
EXHAUST
FAN
WP/
GFI
PP-MC-14
HYDROGEN
MONITOR
C
C.2
MDP
(EXISTING)
PANEL "M"
(EXISTING)
ELECTRIC
TELECOM
DSFCU01
WP/GFI
WP
PNL "M"
-31
PANEL "M" (EXISTING)-1,3
D30
A12
TN502
EXISTING
COMMUNICATION
RACK
6 7 7.1 8 9
D
PP-C-17
GFI
PP-C-19
(TYP)
PP-C-17
GFI
PP-C-19
PP-C-17
GFI
AC
PP-C-15
GFI
AC
PP-C-15
GFI
PP-C-19 PP-C-20
PP-C-20
PP-C-20
PP-C-18
GFI
AC
PP-C-28
GFI
UC
PP-C-32
PP-C-30
PP-C-29
PP-C-13
PP-C-11
PP-C-13
PP-C-23
PP-C-25
PP-C-14
PP-C-13
PP-C-14
GFI
PP-C-14
GFI
AC
PP-C-21
GFI
WPIU
PP-C-20
PP-C-27
PP-C-28
GFI
AC
PP-C-18
GFI
AC
PP-C-16
PP-C-17
GFI
AC
PP-C-20
AUDIO
PP-C-21
GFI
WPIU
PROVIDER/EXAM
ROOM
WAIT
AUDIO
CORRIDOR
VESTIBULE
EMERGENCY/
IMMUNIZATION
114B
PROVIDER/EXAM
ROOM
114A
PROVIDER/EXAM
ROOM
115BMENTAL HEALTH
115A
PP-C-14
PP-C-14
PP-C-20
SEE NOTE #5
SEE NOTE #6
1. SEE SHEET E-001 AND E-002 FOR LEGEND,
ABBREVIATIONS, AND GENERAL NOTES.
2. SEE SHEET EP402 FOR ELECTRICAL ROOM AND
PANELBOARD LOCATIONS.
3. SEE SHEET EP601 PANELBOARD SCHEDULE FOR CONDUIT
AND CONDUCTOR SIZING.
4. PROVIDE EXPANSION/DEFLECTION FITTINGS AT
STRUCTURAL EXPANSION JOINT EXISTING AND NEW.
5. RECEPTACLES MOUNTED ON COUNTER TYPE WS2 BASE
COORDINATE FINAL LOCATION WITH FFE DRAWINGS.
6. RECEPTACLES IN CKT #28 SERVED VIA WALL MOUNTED
UPS LOCATED IN ELECTRICAL ROOM.
GENERAL SHEET NOTES
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S L O
U
IS
V
IL
L E
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L S
T E
L O
U
IS
V
IL
L E
K
Y
A N
S I D
A D
D R
E P
A
IR
R E
S E
R V
E C
O M
P O
N E
N T
M E
D
IC
A
IN
IN
G
F A
C
IL
IT
Y
B
O J N
O F
T F
A C
B
P
A U
G U
S T
V B
R E
D
IC
K A
S
C O
R R
E C
T E
D F
IN
A
L S
U B
M
IT
T
NOT FOR
CONSTRUCTIONPLAN NORTH
P R
O J E
C T
N O
F
T F
A C
B
P
EP402
E L E
C T
R
IC
A L P
O W
E R
E N
L A
R G
E D
P L A
N S
N P
E R
E Z
N H
O A
R A
U
T .M
O R
G A
N
SCALE: 1/4" = 1'-0"
B8
LEVEL 1 POWER - ENLARGED ELECTRICAL ROOM 129 AREA D
SCALE: 1/4" = 1'-0"
B2
LEVEL 1 POWER -ENLARGED ELECTRICAL ROOM 106 AREA C
0 2' 4' 8' 0 2' 4' 8'
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
G2
LEVEL 1 POWER -PROCEDURE ROOMS AREA B
WP
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/0
/2
W
2Q R
-5
7_ C
O R
R Fi na l_
Pl an s-
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S L O
U
IS
V
IL
L E
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L S
T E
L O
U
IS
V
IL
L E
K
Y
A N
S I D
A D
D R
E P
A
IR
R E
S E
R V
E C
O M
P O
N E
N T
M E
D
IC
A
IN
IN
G
F A
C
IL
IT
Y
B
O J N
O F
T F
A C
B
P
A U
G U
S T
V B
R E
D
IC
K A
S
C O
R R
E C
T E
D F
IN
A
L S
U B
M
IT
T
NOT FOR
CONSTRUCTION
P R
O J E
C T
N O
F
T F
A C
B
P
EP601
P A
N E
L S
C H
E D
U L E
S
N P
E R
E Z
N H
O A
R A
U
T .M
O R
G A
N
DEMAND WITH EXPANSION: 139 A
TOTAL ESTIMATED DEMAND... 116 A
TOTAL CONNECTED CURRENT: 135 A
TOTAL ESTIMATED DEMAND LOAD: 41812 VA
TOTAL CONNECTED LOAD: 48692 VA
PANEL TOTALS
TOTAL LOAD: 18349 VA 15189 VA 15153 VA
53 20 1 SPARE -- 0 0 -- SPARE 1 20 54
51 20 1 SPARE -- 0 0 -- SPARE 1 20 52
49 20 1 SPARE -- 0 0 -- SPARE 1 20 50
47 20 1 SPARE -- 0 0 -- SPARE 1 20 48
45 20 1 SPARE -- 0 0 -- SPARE 1 20 46
43 20 1 RECEPTACLE ROOM 164 1-#12, 1-#12, 1-#12 540 0 -- SPARE 1 20 44
41 20 1 RECEPTACLE ROOM 164 1-#12, 1-#12, 1-#12 540 5803 -- -- -- -- 42
39 20 1 RECEPTACLE 1-#12, 1-#12, 1-#12 1440 6203 -- -- -- -- 40
37 20 1 COPIER 1-#12, 1-#12, 1-#12 180 8493 3-#3, 1-#3, 1-#8 PP-MC 3 100 38
35 20 1 FURNITURE FEED 1-#12, 1-#12, 1-#12 180 36
33 20 1 FURNITURE FEED 1-#12, 1-#12, 1-#12 180 720 1-#10, 1-#10, 1-#10 RECEPTACLE 1 20 34
31 20 1 LIGHTING PROVIDER/EXAM ROOM 119B 1-#12, 1-#12, 1-#12 496 1440 1-#10, 1-#10, 1-#10 REC AUDIO 169 1 20 32
29 20 1 REC AUDIO 169 1-#10, 1-#10, 1-#10 1440 1440 1-#10, 1-#10, 1-#10 REC AUDIO 169 1 20 30
27 20 1 REC AUDIO 169 1-#10, 1-#10, 1-#10 1440 360 1-#12, 1-#12, 1-#12 U/C AND A/C REF VIA UPS 1 20 28
25 20 1 REC AUDIO 169 1-#10, 1-#10, 1-#10 1440 180 1-#12, 1-#12, 1-#12 PROVIDER / EXAM ROOM 1 20 26
23 20 1 REC AUDIO 169 1-#10, 1-#10, 1-#10 1440 350 1-#12, 1-#12, 1-#12 LIGHTING ROOM 166, 165, 164, 163, 162 1 20 24
21 20 1 EXTERIOR REC 1-#10, 1-#10, 1-#10 720 706 1-#10, 1-#10, 1-#10 LIGHTING ROOM 167, 166, 165, 164, 16... 1 20 22
19 20 1 PROVIDER / EXAM 1-#12, 1-#12, 1-#12 540 1080 1-#10, 1-#10, 1-#10 EMERGENCY / IMMUNIZATION 1 20 20
17 20 1 PROVIDER / EXAM 1-#12, 1-#12, 1-#12 720 360 1-#12, 1-#12, 1-#12 RECEPTACLE SPACE 95 1 20 18
15 20 1 PROVIDER / EXAM 1-#12, 1-#12, 1-#12 360 1080 1-#10, 1-#10, 1-#10 RECEPTACLE WAIT 160 1 20 16
13 20 1 PROVIDER / EXAM ROOM 1-#12, 1-#12, 1-#12 540 900 1-#10, 1-#10, 1-#10 RECEPTACLE AUDIO 1 20 14
11 20 1 RECEPTACLE AUDIO 169 1-#10, 1-#10, 1-#10 1440 180 1-#12, 1-#12, 1-#12 FURNITURE FEED 1 20 12
9 20 1 CHIEF NURSE'S OFFICE 1-#12, 1-#12, 1-#12 540 180 1-#12, 1-#12, 1-#12 FURNITURE FEED 1 20 10
7 20 1 STORAGE/OFFICE 1-#10, 1-#10, 1-#10 720 540 1-#12, 1-#12, 1-#12 FURNITURE FEED 1 20 8
5 20 1 STORAGE/OFFICE 1-#10, 1-#10, 1-#10 720 540 1-#12, 1-#12, 1-#12 FURNITURE FEED 1 20 6
3 20 1 REC - CHIEF NURSE'S OFFICE 1-#10, 1-#10, 1-#10 720 540 1-#12, 1-#12, 1-#12 FURNITURE FEED 1 20 4
1 20 1 REC - CHIEF NURSE'S OFFICE 1-#10, 1-#10, 1-#10 720 540 1-#12, 1-#12, 1-#12 FURNITURE FEED 1 20 2
# BKR P LOAD SERVED Wire Size A B C Wire Size LOAD SERVED P BKR #
NOTES:
ENCLOSURE: NEMA 1 MCB RATING: 225 A
MOUNTING: SURFACE WIRES: 4 MAINS RATING: 225 A
SUPPLY FROM: MDP (EXISTING) PHASE: 3 MAINS TYPE: MCB
LOCATION: ELECTRICAL 106 VOLTAGE: 208Y/120V A.I.C. RATING: 22000
PANELBOARD: PP-C
DEMAND WITH EXPANSION: 68 A
TOTAL ESTIMATED DEMAND... 57 A
TOTAL CONNECTED CURRENT: 57 A
TOTAL ESTIMATED DEMAND LOAD: 20500 VA
TOTAL CONNECTED LOAD: 20500 VA
PANEL TOTALS
TOTAL LOAD: 8493 VA 6203 VA 5803 VA
29 20 1 SPARE -- 0 0 -- SPARE 1 20 30
27 20 1 SPARE -- 0 0 -- SPARE 1 20 28
25 20 1 SPARE -- 0 0 -- SPARE 1 20 26
23 20 1 SPARE -- 0 0 -- SPARE 1 20 24
21 20 1 SPARE -- 0 22
19 -- -- -- -- 1250 20
17 20 2 DSFCU02 2-#12, 1-#12 1250 18
15 -- -- -- -- 90 16
13 20 2 SITE LIGHTING 2-#12, 1-#12 90 180 1-#12, 1-#12, 1-#12 HYDROGEN MONITOR 1 20 14
11 -- -- -- -- 1667 180 1-#12, 1-#12, 1-#12 POWER ELECTRICAL 106 1 20 12
9 -- -- -- -- 1667 180 1-#12, 1-#12, 1-#12 EXHAUST FAN TOILET 163 1 20 10
7 25 3 FCU 02 3-#10, 1-#10 1667 1040 -- -- -- -- 8
5 -- -- -- -- 1667 1040 2-#10, 1-#10 HP 02 2 20 6
3 -- -- -- -- 1667 2600 -- -- -- -- 4
1 40 3 FCU 01 3-#8, 1-#10 1667 2600 2-#6, 1-#6 HP 01 2 35 2
# BKR P LOAD SERVED Wire Size A B C Wire Size LOAD SERVED P BKR #
NOTES:
ENCLOSURE: NEMA 1 MCB RATING: 100 A
MOUNTING: SURFACE WIRES: 4 MAINS RATING: 100 A
SUPPLY FROM: PP-C PHASE: 3 MAINS TYPE: MCB
LOCATION: ELECTRICAL 106 VOLTAGE: 208Y/120V A.I.C. RATING: 22000
PANELBOARD: PP-MC
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/0
/2
W
2Q R
-5
7_ C
O R
R Fi na l_
Pl an s-
18"
1"
6"
LIGHTING CONDUIT. SIZE
AS INDICATED ON PLANS
FINISHED GRADE
#2 AWG BARE COPPER WIRE.
CONNECT TO GROUND LUG IN
LIGHT POLE
3/4" X 10'-0" COPPER GROUND ROD.
CONNECT TO THE GROUND ROD WITH
ONE #2 BARE STRANDED COPPER
CONDUCTOR USING EITHER A BRONZE
GROUND CLAMP OR EXOTHERMIC WELD.SECTION
REFER TO STRUCTURAL
DRAWING S-511 DETAIL H16
FOR LIGHT POLE
FOUNDATION INFORMATION.
PVC COUPLING (TYP)
PVC CONDUIT (TYP)
LIGHTING CONDUIT.
SIZE AS INDICATED ON
PLANS.
PVC 90 DEGREE ELBOW
MATCH SIZE OF
CONDUIT SHOWN ON
SITE PLANS
PROVIDE ANCHOR
BOLTS WITH POLE
2'-0"
LUMINAIRE ASSEMBLY
LUMINAIRE TYPE AND
QUANTITY PER PLANS.
REFERENCE EL601 FOR LIGHT
FIXTURE SCHEDULE.
POLE SHALL HAVE A MINIMUM 8" BASE
DIAMETER AND HAVE A DARK BRONZE
FINISH TO MATCH LUMINAIRES. COORDINATE
POLE/FIXTURE HEIGHT WITH LIGHT FIXTURE
SCHEDULE ON EL601.
PROVIDE WATERPROOF
FUSEHOLDER WITH 10A RATED FUSE
FOR EACH PHASE CONDUCTOR.
TOP VIEW 19 IN
4 IN
POLE AS
INDICATED
36.5 IN
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-CAST ALUMINUM OR DIE-CAST AND EXTRUDED ALUMINUM WITH INTEGRAL,
SELF-CLEANING HEAT SINK FINS, RIBS, OR EQUIVALENT PASSIVE COOLING MECHANISM.
HEAT SINK SHALL BE INCORPORATED DIRECTLY INTO HOUSING TO ENSURE MAXIMUM HEAT
TRANSFER AND DISSIPATION.
2. FINISH - MULTI-STAGE PRE-TREATMENT, FINISHED WITH BAKED-ON POLYESTER POWDER
COAT. FINISH SHALL PASS 2500 HOUR SALT SPRAY TEST PER ASTM B117. FINISH COLORS
INCLUDE DARK BRONZE, SILVER, OR BLACK WITH CUSTOM COLORS AVAILABLE.
3. POWER SUPPLY/LED DRIVER - PROVIDE IN SEPARATE COMPARTMENT ACCESSIBLE WITHOUT
THE USE OF HAND TOOLS. CLASS 1 DRIVER SHALL OPERATE AT 120/277V, 50/60 HZ; OTHER
VOLTAGES OPTIONAL. POWER FACTOR GREATER THAN 0.9 AND THD LESS THAN 20% AT FULL
LOAD. MINIMUM EFFICACY SHALL BE 60 LM/W AT MAXIMUM 600 mA OPERATING CURRENT.
4. LED OPTICAL ASSEMBLY - NUMBER OF LED ARRAYS SHALL VARY TO ACCOMMODATE DESIRED
LUMINAIRE OUTPUT. PROVIDE WITH EQUIVALENT NEMA TYPE III, IV OR V DISTRIBUTION AS
INDICATED. BUG UPLIGHT RATING OF U0, WITH BACKLIGHT AND GLARE RATINGS AS
DETERMINED BY LIGHTING ZONE INSTALLED. MINIMUM COLOR RENDERING INDEX (CRI) SHALL
BE 70 FOR CORRELATED COLOR TEMPERATURE (CCT) OF 4000 K TO 4500 DEGREES K.
5. SURGE PROTECTION - 6 kV MINIMUM, COMPLIANT WITH ANSI C62.41.2.
6. CERTIFICATION - UL AND/OR ETL LISTED, MINIMUM IP65 RATED PER ANSI/IEC 60529, AND RoHS
COMPLIANT.
7. OPTIONS - PHOTOCELL,RECEPTACLE AND BIRD SPIKES.
8. OTHER - THE ABOVE SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A
LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS AND IS NOT INTENDED TO
INDICATE A CERTAIN MANUFACTURER'S PREFERENCE. ALL DIMENSIONS ARE NOMINAL AND
VARY PER MANUFACTURER.
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S L O
U
IS
V
IL
L E
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L S
T E
L O
U
IS
V
IL
L E
K
Y
A N
S I D
A D
D R
E P
A
IR
R E
S E
R V
E C
O M
P O
N E
N T
M E
D
IC
A
IN
IN
G
F A
C
IL
IT
Y
B
O J N
O F
T F
A C
B
P
A U
G U
S T
V B
R E
D
IC
K A
S
C O
R R
E C
T E
D F
IN
A
L S
U B
M
IT
T
NOT FOR
CONSTRUCTION
P R
O J E
C T
N O
F
T F
A C
B
P
ES502
E L E
C T
R
IC
A L S
IT
E
D E
T A
IL
S
N P
E R
E Z
N H
O A
R A
U
T .M
O R
G A
N
NTSSCALE:
E1
AREA BRONZE LIGHT POLE
NTSSCALE:
F9
LP-3 LED AREA LUMINAIRE
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/0
/2
W
2Q R
-5
7_ C
O R
R Fi na l_
Pl an s-
MENTAL
HEALTH
115A
PROVIDER/EXAM
ROOM
115B
PROVIDER/EXAM
ROOM
114A
EMERGENCY/
IMMUNIZATION
114B
VESTIBULE
AUDIO
PROVIDER/EXAM
ROOM
WAIT
TOILET
PROVIDER/EXAM
ROOM
OPEN WORK
STATIONS
CHIEF NURSE'S
OFFICE
PUBLIC
HEALTH
OFFICE
STORAGE/OFFICE
DEPLOYMENT
HEALTH
OFFICE
WS1
WS1
C1AC2
C2
C2
C2 C1A
C1AC2
C2
C2
C2
C1A
C4A
C2
C3 C3 C3 C3 C3C3C3C3
C3 C3 C3
C1B C1B C1B
C1B C1B C1B
C1B C1B C1B
C1B C1B C1B
D1
D1
D1
D1
T1
T1
C4A
C2
A1
C4B C4A
C4A
C4AC4A
C4A C2 C2
C2
C3 C3 C3 C3
D2
D3 D3
D2
T2 T2A1
A1 A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
EQ1
FUTURE MONITOR
WS2
C3 C3
F1
F1
F1
F1
F1
F1
WS1
WS1 CORRIDOR
A2
A2 A2
A2
A2
A2
A2
A2
A2 A2A2A2
A2 A2 A2
A2A2A2
A2 A2 A2
A3 A3 A3
A3
A3
A3
A2
A2
A1
DENTAL EXAM
121A
DENTAL EXAM
121B
TRAINING
OFFICE
MED ADMIN
SUPERVISOR
CHIEF NURSE
EQ2
FT1
FT1
FT1
/2
E Q
E Q
2"
E Q
E Q
2' - 2 1/2"
2' - 2 1/2"
2' - 2 1/2"
5' - 0"
EQ2
3' - 3"
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
FURNITURE, FIXTURES AND EQUIPMENT (FF&E) DRAWINGS
PROVIDED FOR COORDINATION WITH BUILDING SYSTEMS
ONLY.
REFER TO ARCHITECTURAL FLOOR PLANS FOR BUILDING
LAYOUT, DIMENSIONS, AND COORDINATION TO BUILDING
SYSTEMS AND STRUCTURE.
REFER TO ELECTRICAL DRAWINGS FOR COORDINATION OF
LIGHTING, POWER, DATA, COMMUNICATIONS, AND LOCATIONS
OF OTHER WALL AND FLOOR MOUNTED ELECTRICAL DEVICES
AND EQUIPMENT FOR COORDINATION TO FURNITURE
LAYOUTS. CONTRACTOR MUST IDENTIFY ANY CONFLICTS WITH
FURNITURE LAYOUTS.
REFER TO MECHANICAL DRAWINGS FOR COORDINATION OF
PLUMBING AND HVAC SYSTEMS TO FURNITURE LAYOUTS.
THERMOSTATS, DIFFUSERS AND ACCESS PANELS MUST NOT
CONFLICT WITH FURNITURE LAYOUTS. CONTRACTOR MUST
IDENTIFY ANY CONFLICTS WITH FURNITURE LAYOUTS.
FIELD VERIFY BUILDING CONDITIONS PRIOR TO INSTALLATION
OF FF&E.
FURNITURE INSTALLER/CONTRACTOR MUST COORDINATE
POWER/COMM/DATA CONNECTIONS WITH ELECTRICAL
CONTRACTOR PRIOR TO INSTALLATION OF ELECTRIFIED
FURNISHINGS.
PROVIDE BLOCKING AS REQUIRED FOR WALL MOUNTED
MARKERBOARDS, TACKBOARDS, STORAGE UNITS OR AV
EQUIPMENT INCLUDING FLAT PANEL DISPLAYS.
INSTALL MARKERBOARDS AND TACKBOARDS AT 3'-0" TO THE
BOTTOM OF THE UNIT UNLESS NOTED OTHERWISE.
INSTALL CLOCKS AT 8'-0" AFF TO CENTER OF CLOCK UNLESS
NOTED OTHERWISE.
FURNITURE AND EQUIPMENT SHOWN DASHED AND
HALFTONED MUST BE GOVERNMENT FURNISHED,
GOVERNMENT INSTALLED (GFGI). GFGI ITEMS ARE NOT
INCLUDED IN THE FF&E PACKAGE AND ARE SHOWN FOR
COORDINATION PURPOSES ONLY. GFGI ITEMS MAY INCLUDE
PRINTERS, COPIERS, FAX MACHINES, SHREDDERS, VENDING
MACHINES AND OTHER ITEMS AS INDICATED.
FF&E CONTRACTOR TO FIELD VERIFY MEASUREMENTS AND
SITE CONDITIONS TO ENSURE PROPER FIT OF FF&E.
FURNISHINGS MUST NOT OVERLAP OR OBSTRUCT DOOR
FRAMES, WALL SWITCHES, THERMOSTATS, OR OTHER WALL
MOUNTED ITEMS. MODIFICATIONS TO FURNISHINGS LAYOUTS
REQUIRED TO MEET BUILDING CONDITIONS AT THE TIME OF
INSTALLATION MUST BE THE RESPONSIBILITY OF THE FF&E
CONTRACTOR. MODIFICATIONS MUST BE APPROVED IN
WRITING BY A GOVERNMENT APPROVED REPRESENTATIVE
PRIOR TO INSTALLATION OF THE FURNISHINGS.
GENERAL SHEET NOTES
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S L O
U
IS
V
IL
L E
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L S
T E
L O
U
IS
V
IL
L E
K
Y
A N
S I D
A D
D R
E P
A
IR
R E
S E
R V
E C
O M
P O
N E
N T
M E
D
IC
A
IN
IN
G
F A
C
IL
IT
Y
B
O J N
O F
T F
A C
B
P
A U
G U
S T
V B
R E
D
IC
K A
S
C O
R R
E C
T E
D F
IN
A
L S
U B
M
IT
T
NOT FOR
CONSTRUCTION
P R
O J E
C T
N O
F
T F
A C
B
P
I-101
O V
E R
A L
L F
U R
N
IT
U R
E P
L A
N
T S
P A
R K
S
T S
P A
R K
S
M O
R S
C H
E L N
SCALE: 1/8" = 1'-0"A1
ENLARGED FURNITURE PLAN
FF&E SCHEDULE
ITEM CODE ITEM DESCRIPTION QUANTITY
ACCESSORIES
A1 MARKER AND TACK BOARD COMBO 60"W X 48"H 14
A2 PERSONAL WASTE RECEPTACLE 23
A3 WALL CLOCK - BATTERY 6
CHAIRS AND SEATING
C1A ERGONOMIC TASK CHAIR - OFFICE - SOFT CASTERS 4
C1B ERGONOMIC TASK CHAIR - OPEN WORKSTATIONS - HARD CASTERS 12
C2 GUEST CHAIR 13
C3 GUEST CHAIR - WAITING 17
C4A ERGONOMIC TASK CHAIR - SOFT CASTERS 7
C4B ERGONOMIC TASK CHAIR - HARD CASTERS 1
DESKS
D1 DESK L-SHAPED, FIXED HEIGHT WORKSURFACES, LOW FILE STORAGE 4
D2 DESK - SINGLE 60"W X 24"D WITH UPPER STORAGE, BBF 2
D3 DESK - SINGLE 48"W X 24"D WITH UPPER STORAGE 2
FILING AND STORAGE
F1 LATERAL FILE 3 DRAWER 42"W X 39"H X 18"D 6
FT1 HIGH PRESSURE LAMINATE FILE TOP 84"W 3
TABLES
T1 SMALL TABLE 2
GFGI SCHEDULE
ITEM CODE ITEM DESCRIPTION QUANTITY
EQUIPMENT
EQ1 FLOOR COPIER 1
EQ2 IMMUNIZATION REFRIGERATOR 2
0 4' 8' 16'
FF&E SCHEDULE
ITEM CODE ITEM DESCRIPTION QUANTITY
T2 EXAM TABLE 2
WORKSTATION / SYSTEMS FURNITURE
WS1 WORKSTATION - 3 PACK 84"W X 84"D EACH, INTERNAL FABRIC PANELS AT
50"H, CORRIDOR SIDE FABRIC PANELS AT 50"H WITH 8"H GLASS TOPPER,
UPPER STORAGE, SPLINE SUPPORT, UNDER WORKSURFACE STORAGE
WS2 WORKSTATION - CHECK-IN TRANSACTION 90"W X 24"D, BBF 1
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/0
/2
W
2Q R
-5
7_ C
O R
R Fi na l_
Pl an s-
| AD101 |
| A-522 |
| Sheets |
| A-522 - PENETRATION DETAILS |
| A-571 |
| S-514 |
| Sheets |
| S-514 - FRAMING DETAILS |
| EP402 |
| Sheets |
| EP402 - ELECTRICAL POWER ENLARGED PLANS |
| EP601 |
| ES502 |
| I-101 |
| Sheets |
| I-101 - OVERALL FURNITURE PLAN |
File details come from the government source that posted it. Updated .