These drawings are detailed electrical and demolition plans for a construction project at Beale Air Force Base, specifically for an Aircrew Readiness Facility. The documents include multiple technical sheets covering demolition floor plans, electrical power diagrams, fire alarm systems, and plumbing fixture schedules. Key technical elements include a 175kW diesel generator, a 300kVA liquid-filled transformer, multiple electrical panels with varying amperage ratings, and comprehensive electrical and fire alarm system configurations. The plans involve removing existing infrastructure, installing new electrical and mechanical systems, and preparing the facility for operational readiness, with specific attention to power distribution, emergency systems, and safety infrastructure.

The project documentation indicates a US Army Corps of Engineers design, with an issue date of August 21, 2024, and revision notes suggesting ongoing refinement of the plans. The electrical systems are complex, featuring multiple panels (1POL1, 1HOL1, LDP), a transfer switch, surge protective devices, and detailed wiring specifications. Fire alarm and communication systems are extensively documented, with zone configurations, silent testing transfer systems, and comprehensive input/output matrices. The demolition plans show a thorough approach to removing existing infrastructure while preserving critical structural elements, with specific notes on protecting existing mechanical, electrical, and structural components during the renovation process.

View the file

Other files for this federal contract opportunity

Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

4.005

4.001

OFFICEOFFICE OFFICE

OFFICE

WOMENS

MENS

TRAINING

TRAINING

TRAINING

STORAGE

MECH /

ELECT /

FIRE

BREAK

ROOM

JAN

4.001

1' -9

5/

8"

4' -4

17'-4 7/8" 6'-4"

4.007 4.520

4.550

4.520

4.580

D C B A

4.008

F.E.C.

F.E.C.

F.

E.

C

4.008

4.008

4.009

4.009

4.009

4.005

DEMOLITION PLAN GENERAL NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

THE GENERAL CONTRACTOR SHALL VERIFY ALL BUILDING AND SITE

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT

BEFORE PROCEEDING WITH ANY SCHEDULED DEMOLITION WORK.

THE GENERAL CONTRACTOR SHALL COORDINATE ARCHITECTURAL,

STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, TECHNOLOGY, AND

PLUMBING WORK AND ALL SUBCONTRACTORS FOR DEMOLITION AND REPAIR

WORK.

IT IS THE INTENT OF THESE DRAWINGS TO INDICATE THE REMOVAL OF ALL

ITEMS WHICH INTERFERE WITH THE FINAL CONSTRUCTION AS SHOWN ON

THE FLOOR PLANS, ELEVATIONS, DETAILS, AND SCHEDULES. ALL FLOOR

FINISHES, BASE, ABANDONED FURNITURE, WINDOW TREATMENTS, SHELVING,

SIGNAGE, AND ROOFING MATERIALS SHALL BE DEMOLISHED IN THEIR

ENTIRETY.

REMOVE ALL ITEMS OF DEMOLITION WORK FROM THE PROJECT DAILY AND

DISPOSE OF PROPERLY.

EXISTING CONCRETE AND STEEL STRUCTURE TO REMAIN, TYP. PROTECT

COLUMNS, PILASTERS, BEAMS, AND SLABS.

THE EXISTING MECHANICAL, ELECTRICAL,TECHNOLOGY, AND PLUMBING

ITEMS AND/OR SYSTEMS, WATER AND ELECTRICAL METERS ARE GENERALLY

INTENDED TO REMAIN. WHERE WORK CONFLICTS WITH NEW WORK,

DEMOLITION OR REROUTING OF EXISTING INFRASTRUCTURE SHALL BE

REQUIRED. REF: MEP FOR ALL ITEMS TO BE REUSED TYP. ALL ITEMS TO BE

DEMOLISHED SHALL BE REMOVED IN THEIR ENTIRETY, BACK TO THE ORIGINAL

SOURCE. SURROUNDING MATERIALS WHICH ARE DISTURBED OR

DEMOLISHED THAT ARE SCHEDULED TO REMAIN SHALL BE PATCHED WITH

LIKE SURROUNDING MATERIALS, TYPICAL.

DEMOLISH CONCRETE FLOOR SLABS AS REQUIRED TO INSTALL NEW

EQUIPMENT, UNDERGROUND CONDUIT, PLUMBING SYSTEMS, AND FLOOR

DRAINS, REF: STRUCTURAL, EQUIPMENT, ELECTRICAL, PLUMBING

DEMOLITION, AND PLUMBING DRAWINGS.

PROTECT EXISTING SURFACES TO REMAIN DURING DEMOLITION AND

CONSTRUCTION.

REPAIR OR REPLACE ANY EXISTING CONSTRUCTION (WINDOWS, WALLS,

DOORS, CEILINGS, FLOORS, ETC.) TO REMAIN WHICH ARE DAMAGED DURING

CONSTRUCTION. REPLACEMENT MATERIAL SHALL MATCH IN KIND.

DEMOLITION LEGEND:

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED, TYP

(U.N.O.)

EXISTING DOOR TO REMAIN

DOOR, FRAME, AND HARDWARE TO BE

DEMOLISHED COMPLETE, TYP (U.N.O.)

1 2

2.3

32.321

4.560

4.580

4.580

4.580

4.580

4.560 4.560

4.580

4.006

ABCD DDGGGG DD

4.560

4.580

4.560

4.560

4.580

4.005

D C B A

2.3

3 2.3 2 1

4.580

4.580

4.560

4.580

4.005

A B C DDD GGGGDD

4.580

4.560

4.580

4.560

DCBA

4.181

4.181

OFFICEOFFICE OFFICE

OFFICE

WOMENS

MENS

TRAINING

TRAINING TRAINING

STORAGE

MECH /

ELECT /

FIRE

BREAK

ROOM

JAN

COVERED

PORCH

4.082

4.082 4.082

4.082

4.082

4.082

4.081

4.081

4.082

4.082

4.570 4.580

D C B A

4.082

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 3 5 7 9

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

FI

LE

N U

M

BE

R

2 4 6 8 10 11 12 13 14 15 16 17 18 19 20

B

A

C

D

E

F

G

H

J

K

L

M

N

P

Fi le

P at h:

Pl ot D at e:

C :\R ev it

Lo ca l\2

4.

-A

-R

_s te ve .w in ne tt.

rv t 4/

/2

9:

:1

AM

AD101

FI

R

ST

F

LO

O

R D

EM

O

LI

TI

O N

P

LA

N

BE

AL

E

AI

R F

O R

C E

BA

SE

, C

AL

IF

O

R N

IA

LO

U

IS

VI

LL

E D

IS

TR

IC

T

M

AR

TI

N

L U

TH

ER

K

IN

G P

L

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

I.

R

O

BE

R

SO

N

I.

R

O

BE

R

SO

N

M .H

ER

M

AN

G . P

AR

KE

R

Au gu st

1, M H

P R

O

JE

C T

N O

0t h

AR

W A

IR

C

R

EW

R

EA

D

IN

ES

S

FA

C

IL

IT

Y R

EN

O

VA

TI

O N

A

D D

IT

IO

N

PR

O

JE

C T

N O

BA

EY

C A

BA

EY

C B

0-

.0

.0

1- A-

R

P2

C

ER

TI

FI

ED

F

IN

AL

(1

) D

ES

IG

N S

U

BM

IT

TA

L

1/8" = 1'-0"A-201 AD101

B1232 EXISTING BUILDING - DEMO FLOOR PLANJ11

GRAPHIC SCALE 1/8" = 1'-0"

KEYED NOTES

4.001 REMOVE EXISTING PLUMBING FIXTURES AND RELATED PIPING. REFER TO

PLUMBING DRAWINGS.

4.005 DEMO EXISTING PORTION OF EXTERIOR WALL AS REQUIRED FOR NEW

DOOR, REFER TO RENOVATION PLANS.

4.006 EXISTING LOUVER TO BE REMOVED. REFERENCE MECHANICAL FOR

ADDITIONAL MECHANICAL DEMO SCOPE

4.007 REMOVE EXISTING OPERABLE PARTITION AND ASSOCIATED COMPONENTS

4.008 REMOVE EXISTING CASEWORK AND ACCESSORIES

4.009 REMOVE EXISTING SEMI-RECESSED FIRE EXTINGUISHER CABINET.

SALVAGE FOR REUSE.

4.081 EXISTING TO REMAIN

4.082 REMOVE EXISTING CEILINGS ENTIRELY, PREP EXISTING SURFACES FOR

NEW FINISHES.

4.181 EXISTING EXT. PLASTER SOFFIT, PROTECT IN PLACE

4.520 REFERENCE CIVIL SHEETS

4.550 REFERENCE FIRE PROTECTION SHEETS

4.560 REFERENCE PLUMBING SHEETS

4.570 REFERENCE MECHANICAL SHEETS

4.580 REFERENCE ELECTRICAL SHEETS

1/8" = 1'-0"AD101

EXISTING BUILDING - EAST ELEVATION - DEMOM3

1/8" = 1'-0"AD101

EXISTING BUILDING - SOUTH ELEVATION - DEMOJ3

1/8" = 1'-0"AD101

EXISTING BUILDING - WEST ELEVATION - DEMOC3

1/8" = 1'-0"AD101

EXISTING BUILDING - NORTH ELEVATION - DEMOF3

1/8" = 1'-0"A-201 AD101

EXISTING BUILDING - RCP - DEMOD11 PLAN NORTH

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

A

PR

W

2Q R

BA

_P la ns -0

ARIMS: 200A Disposition: Maintain for 15yrs after construction

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

2 4 6 8 10 11 12 13 14 15 16 17 18 19 20

B

A

C

D

E

F

G

H

J

K

L

M

N

P

E-002

K E

Y E

D N

O T

E S

B E

A L E

A

IR

F O

R C

E B

A S

E C

A L

IF

O R

N

IA

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

M

A R

T

IN

L U

T H

E R

K

IN

G P

L L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A H

A R

B O

U R

A H

A R

B O

U R

M H

E R

M A

N

J H

U D

O C

K

A U

G U

S T

M H

P R

O J E

C T

N O th

A R

W A

IR

C

R E

W R

E A

D

IN

E S

S F

A C

IL

IT

Y R

E N

O V

A T

IO

N

A

D D

IT

IO

N

P R

O J E

C T

N O

B

A E

Y C

A

B A

E Y

C

B

-2

.0

.0

-E

-R

P

C E

R T

IF

IE

D F

IN

A

L

D

E S

IG

N

S U

B M

IT

T

A L

ELECTRICAL KEYED NOTES

9.001 DISCONNECT AND REMOVE EXISTING PAD-MOUNTED TRANSFORMER AND ASSOCIATED

CONCRETE PAD. EXISTING PAD-MOUNTED TRANSFORMER TO BE DELIVERED TO CIVIL

ENGINEERING BUILDING.

9.002 DISCONNECT AND REMOVE EXISTING MEDIUM VOLTAGE CONDUCTORS AND CONDUIT

BETWEEN PAD-MOUNTED TRANSFORMER AND OVERHEAD POLE.

9.003 DISCONNECT AND REMOVE EXISTING SECONDARY CONDUCTORS AND CONDUIT BETWEEN

TRANSFORMER AND EXISTING PANEL MDP.

9.004 DISCONNECT AND REMOVE EXISTING AIRFIELD STORAGE SHED FEEDER CONDUCTORS

AND CONDUIT FROM SECONDARY OF TRANSFORMER TO EXISTING MANHOLE. FIELD

VERIFY EXISTING FEEDER AND CONDUIT SIZE. COORDINATE PHASING OF THIS WORK WITH

THE INSTALLATION OF THE NEW BUILDING TRANSFORMER.

9.005 DISCONNECT AND REMOVE EXISTING RECEPTACLE AND ASSOCIATED BRANCH CIRCUIT

CONDUCTORS BACK TO SOURCE. EXISTING BACKBOX AND PARTIAL CONDUIT SYSTEM

SHALL REMAIN FOR RE-USE.

9.006 EXISTING AIRFIELD STORAGE SHED FEEDER CONDUCTORS AND CONDUIT SHALL REMAIN.

REFER TO SHEET E-010 FOR NEW WORK ASSOCIATED WITH THIS FEEDER.

9.007 DISCONNECT AND REMOVE EXISTING PANEL MDP.

9.008 DISCONNECT AND REMOVE EXISTING WALL PACK AND ASSOCIATED BRANCH CIRCUIT

CONDUCTORS AND RACEWAY BACK TO SOURCE. PROVIDE BLANK STAINLESS STEEL

COVERPLATE ON EXTERIOR WALL. CAP INTERIOR CONDUIT UPON ENTERING BUILDING.

9.101 FIELD VERIFY EXISTING CONDUIT AND WIRE SIZE CURRENTLY SERVED FROM EXISTING

BUILDING TRANSFORMER. PROVIDE MATCHING CONDUIT AND WIRE SIZE FROM PANEL LDP

TO EXISTING STORAGE BUILDING HANDHOLE. COORDINATE PHASING OF THIS WORK WITH

THE REMOVAL OF EXISTING CONDUITS. FOR BIDDING PURPOSES ONLY, PROVIDE 4#2,

1#6G. IN 1-1/2"C.

9.104 AFCI RECEPTACLE IN WASH AREA TO BE FIRST DEVICE ON CIRCUIT AND FEED THROUGH

TO REMAINING ADJACENT SLEEPING ROOM RECEPTACLES ON SAME CIRCUIT.

9.105 PROVIDE 2-WAY 5" CONCRETE ENCASED DUCTBANK BETWEEN SERVICE TRANSFORMER

T-X AND PAD-MOUNTED SWITCH. REFER TO A5/E-501 FOR DUCTBANK DETAILS.

9.106 PROVIDE 4-WAY 5" CONCRETE ENCASED DUCTBANK BETWEEN PAD-MOUNTED SWITCH

AND EXISTING MANHOLE EMH-2. REFER TO A1/E-501 FOR DUCTBANK DETAILS. ELECTRICAL

CONTRACTOR TO PERFORM WORK IN EXISTING EMH-2 NECESSARY TO INSTALL

CONCRETE ENCASED DUCTBANK.

9.107 PROVIDE 4-WAY 3" CONCRETE ENCASED DUCTBANK BETWEEN SERVICE TRANSFORMER

T-X AND SERVICE ENTRANCE DISCONNECT SWITCH. REFER TO A1/E-501 FOR DUCTBANK

DETAILS.

9.108 INSTALL DISCONNECT SWITCH ON EQUIPMENT. COORDINATE INSTALLATION LOCATION

WITH MANUFACTURER REQUIREMENTS.

9.109 INTERCEPT EXISTING CONDUIT BELOW GRADE, PROVIDE COUPLING AND EXTEND CONDUIT

TO PANEL LDP.

9.110 ELECTRICAL CONTRACTOR SHALL FURNISH, INSTALL AND WIRE BATTERY CHARGER,

COOLANT HEATER, AND RECEPTACLE / LIGHTS TO MEET UFC REQUIREMENTS. FACTORY

INSTALLED DEVICES ARE NOT ACCEPTABLE.

9.111 INSTALL RECEPTACLE IN EXISTING BACKBOX. INTERCEPT EXISTING CONDUIT AND

EXTEND TO PANEL INDICATED.

9.113 MOUNT DEVICES TO CABLE TRAY ABOVE. SEE C14/E-502 FOR MOUNTING DETAIL.

9.114 RECEPTACLES TO BE HORIZONTALLY MOUNTED AT 3'-6" AND 6'-6" AFF AT BUNK BED. SEE

DETAIL A1/I-702 FOR ADDITIONAL MOUNTING INFORMATION.

9.115 REFER TO SPECIFICATION SECTION 26 27 13.10 30 FOR DIGITAL METER REQUIREMENTS.

9.116 GROUND PER NEC ARTICLE 250 AND DETAIL A1/E-502.

9.117 PROVIDE 2#12AWG IN 1"C. BETWEEN START CONTACTS ON TRANSFER SWITCH AND

GENERATOR CONTROL PANEL.

9.119 COORDINATE CIRCUIT BREAKER SIZE WITH FIELD VERIFY WIRE SIZE PRIOR TO ORDERING

PANEL LDP.

ELECTRICAL KEYED NOTES

9.120 CONCRETE PAD BY OTHERS. COORDINATE TRANSFORMER PAD LOCATION AND SIZE WITH

DIVISION 03 CONTRACTOR.

9.121 PROVIDE 2'-0" X 4" HIGH COPPER GROUND BUS WITH INSULATED STAND OFFS AT 12" AFF.

PROVIDE #3/0 BARE COPPER IN 2"C. BETWEEN GROUND BUS IN KLAXON ROOM AND

GROUND BUS IN ELECTRICAL ROOM.

9.122 PROVIDE MEDIUM VOLTAGE SPLICE WITHIN EXISTING MANHOLE.

9.123 PROVIDE JUNCTION BOX ABOVE CEILING FOR FUTURE MOTORIZED SCREEN.

9.124 PROVIDE RED, LOCKABLE CIRCUIT BREAKER WITH A RED LAMINATED PLASTIC NAMEPLATE

WITH WHITE CENTER CORE INSCRIBED WITH "FIRE PROTECTION ' LIFE SAFETY

EQUIPMENT".

9.125 PROVIDE MULTI-PANEL DIGITAL METER TO MONITOR INDIVIDUAL FEEDERS / CIRCUIT

BREAKERS AS SHOWN. PROVIDE DIGITAL METER ON FACE OF PANEL.

9.127 CLIN 001 UMMC ADDITION: PROVIDE 400A, WALL MOUNTED, NEMA 3R COMBINATION

MANUAL TRANSFER SWITCH (DOUBLE THROW SWITCH) WITH CENTER OFF POSITION.

CABINET SHALL CONTAIN A FUSED MAIN, PHASE ROTATION METER, AND SILVER PLATED

COPPER BUS WITH GENERATOR CAMLOCKS. UNDER CLIN 003, BID OPTION 2, THIS

EQUIPMENT DOES NOT GET FURNISHED, INSTALLED, AND WIRED.

9.128 INSTALL CONDUITS UNDERGROUND INTO BASE OF SERVICE ENTRANCE RATED CIRCUIT

BREAKER. COORDINATE SAW CUTTING OF EXISTING CONCRETE SLAB WITH GENERAL

CONTRACTOR.

9.201 MOUNT PHOTOCELL ON NORTHWEST CORNER OF ROOF FACING NORTH.

9.202 ROOM CONTROLLER TO BE PROVIDED WITH AN OUTDOOR CONTACT INPUT FOR A

PHOTOCELL.

9.203 EXHAUST FAN CONTROLLED BY SHOWER TIMER SWITCH. WIRE BRANCH CIRCUIT

THROUGH TIMER SWITCH. REFER TO POWER PLANS FOR LOCATION OF EXHAUST FAN.

9.301 PROVIDE 4#10, 1#10G IN 3/4"C BETWEEN PANELBOARD AND SURGE PROTECTIVE DEVICE

(SPD). MOUNT SPD ADJACENT TO PANEL.

9.302

9.305 LABEL SWITCH 'DISPOSAL'.

9.306 COORDINATE INSTALLATION WITH CEILING TELECOMMUNICATION OUTLET. INSTALL IN

SAME CEILING TILE.

9.401 PROVIDE #1/0 COPPER DOWN CONDUCTOR FROM ROOF TO GROUND TERMINAL AS

INDICATED. DOWN CONDUCTOR SHALL BE ROUTED IN CONDUIT INTERIOR TO THE

BUILDING. AND WITHIN CMU/STUD CAVITY WHEREVER POSSIBLE.

9.402 LIGHTNING PROTECTION SYSTEM GROUND TERMINALS SHALL BE MINIMUM 5/8" X 8'-0"

COPPER-CLAD STEEL GROUND ROD BURIED INTO EARTH 1'-6" TO TOP OF GROUND ROD.

CONDUCTORS SHALL BE PERMANENTLY CONNECTED TO GROUND TERMINAL WITH

EXOTHERMIC WELD. PROVIDE GROUND ROD ACCESS WELLS WHERE SHOWN ON PLANS.

TYPICAL FOR ALL UNLESS NOTED OTHERWISE.

9.403 PROVIDE #1/0 AL MAIN LIGHTNING CONDUCTOR FOR INTERCONNECT OF ALL AIR

TERMINALS ON THE ROOF. CONDUCTOR SHALL ROUTE CONCEALED BENEATH THE METAL

ROOF PANELS.

9.404 CONNECT LIGHTNING PROTECTION SYSTEM GROUND RING TO BUILDING GROUND VIA

MAIN GROUND BAR IN THE ELECTRICAL ROOM.

9.405 PROVIDE A #1/0 BARE COPPER COUNTERPOISE GROUND RING SYSTEM INSTALLED A

MINIMUM OF 3'-6" AWAY FROM THE STRUCTURE. GROUND RING SHALL BE BURIED AT

LEAST 30" BELOW GRADE.

9.406 20'-0" MAXIMUM SEPARATION BETWEEN AIR TERMINALS ALONG THE ROOF PERIMETER AND

AS SHOWN (TYPICAL). IF AIR TERMINALS ARE GREATER THAN 24IN TALL, 25' MAXIMUM

SEPARATION BETWEEN AIR TERMINALS IS PERMITTED.

9.407 COORDINATE LOCATION OF GROUND RODS WITH CIVIL FOR DEMOLITION/REPLACEMENT

OF CONCRETE SECTIONS AS NEEDED FOR GROUND ROD AND DOWN CONDUCTOR

INSTALLATION.

9.408 BOND LIGHTNING PROTECTION SYSTEM TO ALL NEW AND EXISTING ROOF MOUNTED HVAC

EQUIPMENT, ROOF LADDER, VENT DUCTS AND ANTENNAS. COORDINATE EXACT

LOCATIONS IN FIELD WITH OTHER TRADES.

9.409 INSTALL GROUND CONDUCTOR UNDERNEATH CONCRETE WALK PATH. COORDINATE WITH

CIVIL PRIOR TO INSTALLATION.

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

A

P R

W

2Q R

BA

_P la ns -0

W /D

W /D

C

J

E-401

J13

C

AB

MISSION PLANNING

OFFICE

MISSION PLANNING SIPR

DINING/GATHERING

LAUNDRY

RR

KITCHEN

MECH

ELEC

COMM

KLAXON

SLEEPING ROOM

SLEEPING ROOM

125A

WASH AREA

125B

TOILET / SHOWER

SLEEPING ROOM

SLEEPING ROOM

121B

TOILET / SHOWER

121A

WASH AREA

122A

WASH AREA

122B

TOILET / SHOWER

SLEEPING ROOM

SLEEPING ROOM

126B

TOILET / SHOWER

126A

WASH AREA

CORRIDOR

SLEEPING ROOM

SLEEPING ROOM

CORRIDOR

SLEEPING ROOM

131B

TOILET / SHOWER

131A

WASH AREA

SLEEPING ROOM

SLEEPING ROOM

SLEEPING ROOM

SLEEPING ROOM

132A

WASH AREA

SLEEPING ROOM

135B

TOILET / SHOWER

CORRIDOR

136A

WASH AREA

136B

TOILET / SHOWER

SLEEPING ROOM

SLEEPING ROOM

SLEEPING ROOM

SLEEPING ROOM

139B

TOILET / SHOWER

SLEEPING ROOM

139A

WASH AREA

140A

WASH AREA

140B

TOILET / SHOWER

SLEEPING ROOM

ACCU-2

ACCU-1

EWH-1

EF-1

EWH-2

EF-2

EWH-10

EF-10

EWH-9

EF-9

EWH-3

EF-3

EWH-8

EF-8

EWH-4

EF-4

EWH-7

EF-7

EWH-5

EF-5

EWH-6

EF-6

VAV-03VAV-01

VAV-04

VAV-02

VAV-05

VAV-06

VAV-07

VAV-08

VAV-09

VAV-10

VAV-11

VAV-12

VAV-13

VAV-14

VAV-15

VAV-16

VAV-17

VAV-18

VAV-19

VAV-20

VAV-24

VAV-22

E-401

J8

E-401

J2

VAV-25

VAV-21

E-401

B8

132B

TOILET / SHOWER

E-401

E13

EWC/GFCI

WP/GFCI

WP/GFCI

WP/GFCI

WP/GFCI

WP/GFCI

E-401

B13

WP/GFCI

WP/GFCI

WP/GFCI

WP/GFCI

WP/GFCI

JJ HH GG FF EE DD CC BB AA

9.104 9.104 9.104 9.104 9.104 9.104 9.104 9.1049.104 9.104

9.104 9.104 9.104 9.104 9.104

9.104

9.104 9.104 9.104

302626

1HOL2-6

19 23 19

1HOL2-2

1POL1-38

1HOL1-10,12

1HOL1-14,16

9 9

1HOL2-17

1HOL1-5

1LOL1-3

11 11

11 11

1HOL2-21

13 13

1HOL2-25

1HOL1-7

1LOL1-3

15 17

15 15

1HOL2-29

17 17

1HOL2-33

1HOL1-9

1LOL1-3

1HOL2-37

20 20

1HOL2-39

1LOL1-7

1HOL1-11

18 18

1HOL2-351HOL2-31

16 16

1LOL1-7

1HOL1-13

12 12

1HOL2-23

14 14

1HOL2-27

1HOL2-19

1HOL1-15

1LOL1-7

2 2

1HOL2-15

1LOL1-7

1HOL1-17

4 4

1HOL2-111HOL2-7

6 6

8 8

8 8

1HOL2-3

1HOL1-19

1LOL1-7

1HOL2-1

1HOL1-1

1LOL1-3

5 5

1HOL2-5

1HOL2-9

1HOL1-3

1LOL1-3

1 1

21 1HOL2-13

1HOL2-41

WP/GFCI

CIRCUIT ALL 120V

RECEPTACLES TO PANEL

1POL2 UNLESS NOTED

OTHERWISE.

CIRCUIT ALL 120V

RECEPTACLES TO PANEL

1POL1 UNLESS NOTED

OTHERWISE.

CIRCUIT ALL 120V

RECEPTACLES TO PANEL

1POL2 UNLESS NOTED

OTHERWISE.

CIRCUIT ALL 120V

RECEPTACLES TO PANEL

1POL1 UNLESS NOTED

OTHERWISE.

ACCU-3

1HOL1-6,8

9.111

7 7

9.1149.114TYP.

9.1149.114TYP.

1POL1-35

EHO

42"

42"

42"

42"

5 1 11

9.104 135A

WASH AREA

15 19

20161226

AFCI/GFCI AFCI/GFCI AFCI/GFCI AFCI/GFCI AFCI/GFCI

AFCI/GFCIAFCI/GFCIAFCI/GFCIAFCI/GFCIAFCI/GFCI

USB

USB USB USB USB USB USB USB USB USB USB

USBUSBUSBUSBUSB

USBUSBUSB

USB

9.306

9.123

9.111

9.127

60" 60"

72"

72"

ACCU-4

1HOL1-32,34

FCU-1

GENERAL NOTES:

1. REFER TO SHEET E-602 FOR CONNECTION REQUIREMENTS FOR

EQUIPMENT.

2. ALL EXTERIOR DISCONNECT SWITCHES SHALL BE NEMA 3R RATED.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

2 4 6 8 10 11 12 13 14 15 16 17 18 19 20

B

A

C

D

E

F

G

H

J

K

L

M

N

P

E-101

P O

W E

R F

L O

O R

P

L A

N

B E

A L E

A

IR

F O

R C

E B

A S

E C

A L

IF

O R

N

IA

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

M

A R

T

IN

L U

T H

E R

K

IN

G P

L L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A H

A R

B O

U R

A H

A R

B O

U R

M H

E R

M A

N

J H

U D

O C

K

A U

G U

S T

M H

P R

O J E

C T

N O th

A R

W A

IR

C

R E

W R

E A

D

IN

E S

S F

A C

IL

IT

Y R

E N

O V

A T

IO

N

A

D D

IT

IO

N

P R

O J E

C T

N O

B

A E

Y C

A

B A

E Y

C

B

-2

.0

.0

-E

-R

P

C E

R T

IF

IE

D F

IN

A

L

D

E S

IG

N

S U

B M

IT

T

A L

KEYED NOTES

9.104 AFCI RECEPTACLE IN WASH AREA TO BE FIRST DEVICE ON CIRCUIT AND

FEED THROUGH TO REMAINING ADJACENT SLEEPING ROOM RECEPTACLES

ON SAME CIRCUIT.

9.111 INSTALL RECEPTACLE IN EXISTING BACKBOX. INTERCEPT EXISTING

CONDUIT AND EXTEND TO PANEL INDICATED.

9.114 RECEPTACLES TO BE HORIZONTALLY MOUNTED AT 3'-6" AND 6'-6" AFF AT

BUNK BED. SEE DETAIL A1/I-702 FOR ADDITIONAL MOUNTING INFORMATION.

9.123 PROVIDE JUNCTION BOX ABOVE CEILING FOR FUTURE MOTORIZED SCREEN.

9.127 CLIN 001 UMMC ADDITION: PROVIDE 400A, WALL MOUNTED, NEMA 3R

COMBINATION MANUAL TRANSFER SWITCH (DOUBLE THROW SWITCH) WITH

CENTER OFF POSITION. CABINET SHALL CONTAIN A FUSED MAIN, PHASE

ROTATION METER, AND SILVER PLATED COPPER BUS WITH GENERATOR

CAMLOCKS. UNDER CLIN 003, BID OPTION 2, THIS EQUIPMENT DOES NOT

GET FURNISHED, INSTALLED, AND WIRED.

9.306 COORDINATE INSTALLATION WITH CEILING TELECOMMUNICATION OUTLET.

INSTALL IN SAME CEILING TILE.

1/8" = 1'-0"E-101

FIRST FLOOR POWER PLANA1

GRAPHIC SCALE 1/8" = 1'-0"

PLAN NORTH

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

A

P R

W

2Q R

BA

_P la ns -0

T

EGB

GAP

W /D

W /D

M

EGB

PANEL 1POL1

PANEL 1HOL1

PANEL 1LOL1

PANEL 1HOM1

PANEL MDP

PANEL LDP

AB

PANEL 1POL2

INV-A

PANEL 1HOL2

1POL1-27

FA-1

SERVICE

ENTRANCE

DISCONNECT

FACP

FA-3

NAC

9.120

46"

AC-3

ELEC

ATS

PANEL FA

INSTALLED IN

BID OPTION 2

T -L

D P

C

DW

GFCI

GFCI

GFCI

GFCI GFCI GFCI

GFCI

OVEN

SHUT

1POL1-20,22

1POL1-2

KH-1

1HOL1-31

VAV-26

1HOL1-29

24"

GFCI

9.305

KITCHEN

GFCI

GFCI

GFCI

C

WASHER/DRYER

WASHER/DRYER

L14-30R

L14-30R

1POL1-5,7

1POL1-9,11

1POL1-23

GFCI

LAUNDRY

1POL1-25

1LOL1-1 1HOL1-21

1POL1-25

RR

GFCI

GFCI

EF-11 EWH-11

EWH-12

1HOL1-28,30

CP-1

EWHP-1

EWHP-2

AHU-1

AHU-1H

GFCI

GG

1HOM1-7,9,11

1HOM1-13,15,17

1POL2-25

1HOL1-18

1HOL1-24,26

1HOL1-20,22

ACCU-5

1HOM1-19,21,23

9.108

46"

MECH

WP/GFCI

1POL2-22

EF-12

1HOL1-23

TCP

1HOL1-25

EUH-1

1HOL1-2,4

B

AC-2

L6-30R

L6-30R

L5-20R

L5-20R

DD

1POL3-4

1POL3-11

1POL3-7,9

1POL3-5

1POL3-1,3

1POL3-2

PANEL 1POL31POL3-6

9.113

9.113

1POL3-8

COMM

1POL3-13

1POL3-15

INSTALL IN ACCESS

CONTROL PANEL

INSTALL IN INTRUSION

DETECTION PANEL

AC-1

DD

1POL1-28 1POL1-1

KLAXON

9.121

46"

1/4" = 1'-0"E-101 E-401

ENLARGED ELECTRICAL ROOMJ13

1/4" = 1'-0"E-101 E-401

ENLARGED KITCHENJ8

1/4" = 1'-0"E-101 E-401

ENLARGED MECH 111J2

1/4" = 1'-0"E-101 E-401

ENLARGED LAUNDRY 104B8

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

2 4 6 8 10 11 12 13 14 15 16 17 18 19 20

B

A

C

D

E

F

G

H

J

K

L

M

N

P

E-401

E N

L A

R G

E D

P L A

N S

B E

A L E

A

IR

F O

R C

E B

A S

E C

A L

IF

O R

N

IA

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

M

A R

T

IN

L U

T H

E R

K

IN

G P

L L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A H

A R

B O

U R

A H

A R

B O

U R

M H

E R

M A

N

J H

U D

O C

K

A U

G U

S T

M H

P R

O J E

C T

N O th

A R

W A

IR

C

R E

W R

E A

D

IN

E S

S F

A C

IL

IT

Y R

E N

O V

A T

IO

N

A

D D

IT

IO

N

P R

O J E

C T

N O

B

A E

Y C

A

B A

E Y

C

B

-2

.0

.0

-E

-R

P

C E

R T

IF

IE

D F

IN

A

L

D

E S

IG

N

S U

B M

IT

T

A L

1/4" = 1'-0"E-101 E-401

ENLARGED COMM 113E13

1/4" = 1'-0"E-101 E-401

ENLARGED KLAXONB13

NOTE: ALL 120V OUTLETS FED FROM PANEL 1POL1, UNLESS NOTED OTHERWISE.

KEYED NOTES

9.108 INSTALL DISCONNECT SWITCH ON EQUIPMENT.

COORDINATE INSTALLATION LOCATION WITH

MANUFACTURER REQUIREMENTS.

9.113 MOUNT DEVICES TO CABLE TRAY ABOVE. SEE

C14/E-502 FOR MOUNTING DETAIL.

9.120 CONCRETE PAD BY OTHERS. COORDINATE

TRANSFORMER PAD LOCATION AND SIZE WITH

DIVISION 03 CONTRACTOR.

9.121 PROVIDE 2'-0" X 4" HIGH COPPER GROUND BUS WITH

INSULATED STAND OFFS AT 12" AFF. PROVIDE #3/0

BARE COPPER IN 2"C. BETWEEN GROUND BUS IN

KLAXON ROOM AND GROUND BUS IN ELECTRICAL

ROOM.

9.305 LABEL SWITCH 'DISPOSAL'.

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

A

P R

W

2Q R

BA

_P la ns -0

PAD-MOUNTED SWITCH

15KV, 600A

WITH CONCRETE PAD BY

ELECTRICAL CONTRACTOR

PROVIDE 4W5" CONCRETE-

ENCASED DUCTBANK.

SEE DUCTBANK DETAIL A1/E-501

EXISTING MANHOLE - EMH-2

EXISTING DUCTBANK TO

POWER POLE D8-111

EXISTING DUCTBANK TO

SQUAD OPS PAD

MOUNTED SWITCH

600A

200A

3P 600A

200A

3P

600A 3P

SURGE ARRESTOR,

TYPICAL

LIQUID-FILLED TRANSFORMER

WITH CONCRETE PAD BY

ELECTRICAL CONTRACTOR

SIZE: 300KVA

PRI:12,470V, 3PH-3W

SEC: 480Y/277V - 3PH-4W

Z%: 5.75%

T-X

200A

25A

3P

EXTEND (2) 5" CONDUITS 5'

BEYOND THE EDGE OF THE

CONCETE PAD TO THE

EAST. CAP AND LABEL AS

SPARE.

PROVIDE 2W5" CONCRETE-

ENCASED DUCTBANK.

SEE DUCTBANK DETAIL A5/E-501

EPO

GAP

350A/3P

4W3" DUCTBANK

SEE DUCTBANK

DETAIL A1/E-501

GEN-1

175KW / 219KVA, 480Y/277V, 3PH, 4W, 0.8 PF,

TIER 4 CUMMINS DIESEL GENERATOR IN WP

ENCLOSURE, WITH 325 GALLON SUB-BASE TANK,

AND LOAD BANK CIRCUIT BREAKER

SERVICE ENTRANCE ENCLOSED C/B

VOLTAGE: 480/277V-3PH-4W

IC RATING: 25,000 RMS SYM @ 480V

NEMA 1

BUILDING

ENTRANCE

(2) SETS: (4) #4/0 AWG, (1) #1/0GND IN 4"C.

(2) SETS: 4" SPARE CONDUITS

LOAD

BANK

NEMA 3R

350A/3P

100%

LOAD RATED

MDP - 400A BUS, 480/277V-3PH-4W

MINIMUM BREAKER IC RATING = 25,000 RMS

SYM @ 480V

(4) - 100A/3P

PREPARED

SPACES

400A 3P

30A 3P

SPD

PANEL

1HOM1

ELEC

125A 3P

300A 3P

ELEC 107

125Y

ATS

400A, 480Y/277V

4-POLE, SWITCHED NEUTRAL

PROGRAMMED TRANSITION

WCR = 42,000A @480V NEC 702

DPM

TAG: 'T-LDP'

SIZE: 225KVA

PRI: 480V, 3PH, 3W

SEC: 120Y/208V, 3PH, 4W

DRY TYPE TRANSFORMER

PAD-MOUNTED

9.301

30Y

G

N

9.115

400A 3P

L

N E

600A 3P

600Y

(MAX 10'-0")

(2) SETS: (4) #4/0 AWG, (1) #1/0GND IN 4"C.

(2) SETS: (4) #4/0 AWG, (1) #1/0GND IN 4"C.

(2) SETS: 4" SPARE CONDUITS

(4) #500, (1) #1/0GND IN 3-1/2"C.

(2) SETS: (4) #4/0 AWG, (1) #1/0GND IN 4"C.

9.116

9.117

ELEC 107

POWER PANEL CONSTRUCTION

LDP - 800A BUS, 208/120V-3PH-4W

MINIMUM BREAKER IC RATING = 10,000 RMS

SYM @ 208V

ELEC 107

225A 3P

PANEL

1POL1

ELEC

100A 3P

PANEL

1POL2

ELEC

225A 3P

PANEL

1HOL1

ELEC

100A 3P

PANEL

1LOL1

ELEC

225Y 100Y 225Y100Y

EMERGENCY SOURCE

LIGHTING INVERTER

INV-A; ROOM 103

100A 3P

PANEL

1HOL2

ELEC

100Y

100A 3P

PANEL

1POL3

COMM

100Y

2#12, 1#12G. IN 3/4"C.

POWER PANEL CONSTRUCTION

30Y

LSI

; LSI

; LSI

; LSI

200A 3P

200A 3P

SIZE PER MANUFACTURER

RECOMMENDATIONS.

CONFIRM LABLEING

WITH INSTALLATION

SPD9.301

30Y

9.1229.122

(3) - #4/0 AL (15KV) IN

DUCTBANK.

(3) - #4/0 AL (15KV)

IN DUCTBANK.

ALL ITEMS IN DASHED

LINE ARE PART OF

BID OPTION 2.

30A 3P

SPD

9.301

100A 3P

FUTURE

PV

INVERTER

TO EXISTING AIRFIELD

STORAGE SHED MANHOLE

100A 3P

E

9.101

9.119(4) - 100A/3P

PREPARED

SPACES

60A 3P

PANEL

FA

ELEC

60Y

9.124

DPM

DPM DPM DPM DPM DPM DPM DPM DPM DPM9.125TYP

9.125

N E

L

9.127

DPM

(TYP)

9.128

ONE-LINE GENERAL NOTES:

1. REFER TO THE EQUIPMENT CONNECTION SCHEDULE ON

SHEET E-602

2. REFER TO SHEETS E-603 - E-607 FOR PANEL SCHEDULES.

3. ALL WIRING TERMINATIONS BY ELECTRICAL CONTRACTOR.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

2 4 6 8 10 11 12 13 14 15 16 17 18 19 20

B

A

C

D

E

F

G

H

J

K

L

M

N

P

E-701

O N

E -L

IN

E

D

IA

G R

A M

B E

A L E

A

IR

F O

R C

E B

A S

E C

A L

IF

O R

N

IA

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

M

A R

T

IN

L U

T H

E R

K

IN

G P

L L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A H

A R

B O

U R

A H

A R

B O

U R

M H

E R

M A

N

J H

U D

O C

K

A U

G U

S T

M H

P R

O J E

C T

N O th

A R

W A

IR

C

R E

W R

E A

D

IN

E S

S F

A C

IL

IT

Y R

E N

O V

A T

IO

N

A

D D

IT

IO

N

P R

O J E

C T

N O

B

A E

Y C

A

B A

E Y

C

B

-2

.0

.0

-E

-R

P

C E

R T

IF

IE

D F

IN

A

L

D

E S

IG

N

S U

B M

IT

T

A L

N.T.S.E-701

ONE-LINE POWER DIAGRAMA1

KEYED NOTES

9.101 FIELD VERIFY EXISTING CONDUIT AND WIRE SIZE

CURRENTLY SERVED FROM EXISTING BUILDING

TRANSFORMER. PROVIDE MATCHING CONDUIT AND

WIRE SIZE FROM PANEL LDP TO EXISTING STORAGE

BUILDING HANDHOLE. COORDINATE PHASING OF THIS

WORK WITH THE REMOVAL OF EXISTING CONDUITS. FOR

BIDDING PURPOSES ONLY, PROVIDE 4#2, 1#6G. IN 1-1/2"C.

9.115 REFER TO SPECIFICATION SECTION 26 27 13.10 30 FOR

DIGITAL METER REQUIREMENTS.

9.116 GROUND PER NEC ARTICLE 250 AND DETAIL A1/E-502.

9.117 PROVIDE 2#12AWG IN 1"C. BETWEEN START CONTACTS

ON TRANSFER SWITCH AND GENERATOR CONTROL

PANEL.

9.119 COORDINATE CIRCUIT BREAKER SIZE WITH FIELD VERIFY

WIRE SIZE PRIOR TO ORDERING PANEL LDP.

9.122 PROVIDE MEDIUM VOLTAGE SPLICE WITHIN EXISTING

MANHOLE.

9.124 PROVIDE RED, LOCKABLE CIRCUIT BREAKER WITH A RED

LAMINATED PLASTIC NAMEPLATE WITH WHITE CENTER

CORE INSCRIBED WITH "FIRE PROTECTION ' LIFE SAFETY

EQUIPMENT".

3. FEEDER SIZES SHOWN ON THE RISER DIAGRAM INDICATE FEEDER

AMPACITIES AND DO NOT NECESSARILY CORRESPOND TO THE CIRCUIT

BREAKER AMPACITIES. CERTAIN FEEDERS MAY BE SIZED FOR DERATION

FACTORS AND/OR OVERSIZED FOR VOLTAGE DROP PER NEC

REQUIREMENTS.

2. ALL THE CONDUCTOR AMPACITIES ARE BASED ON TABLE 310.16 OF THE NEC

FOR COPPER CONDUCTORS (75 DEGREE CELSIUS CHART).

1. THE SCHEDULE IS A SCHEDULE OF TYPICAL FEEDERS AND SOME OF THE

SIZES MAY NOT APPLY TO THIS PROJECT.

SCHEDULE NOTES:

600Y 600 2 3 - 350 1 - 350 1 - # 1 - 3"

600 600 2 3 - 350 - 1 - # 1 - 3"

400Y 400 2 3 - # 3/0 1 - # 3/0 1 - # 3 - 2-1/2"

400 400 2 3 - # 3/0 - 1 - # 3 - 2"

300Y 300 1 3 - 350 1 - 350 1 - # 4 - 3-1/2"

300 300 1 3 - 350 - 1 - # 4 - 3"

250Y 250 1 3 - 250 1 - 250 1 - #4 - 3"

250 250 1 3 - 250 - 1 - #4 - 2-1/2"

225Y 225 1 3 - # 4/0 1 - # 4/0 1 - # 4 - 2-1/2"

225 225 1 3 - # 4/0 - 1 - # 4 - 2"

200Y 200 1 3 - # 3/0 1 - # 3/0 1 - # 6 - 2-1/2"

200 200 1 3 - # 3/0 - 1 - # 6 - 2"

175Y 175 1 3 - # 2/0 1 - # 2/0 1 - # 6 - 2"

175 175 1 3 - # 2/0 - 1 - # 6 - 2"

150Y 150 1 3 - # 1/0 1 - # 1/0 1 - # 6 - 2"

150 150 1 3 - # 1/0 - 1 - # 6 - 1-1/2"

125Y 125 1 3 - # 1/0 1 - # 1/0 1 - # 6 - 2"

125 125 1 3 - # 1/0 - 1 - # 6 - 1-1/2"

110Y 110 1 3 - # 2 1 - # 2 1 - # 6 - 1-1/4"

110 110 1 3 - # 2 - 1 - # 6 - 1-1/4"

100Y 100 1 3 - # 3 1 - # 3 1 - # 8 - 1-1/4"

100 100 1 3 - # 3 - 1 - # 8 - 1-1/4"

90Y 90 1 3 - # 3 1 - # 3 1 - # 8 - 1-1/4"

90 90 1 3 - # 3 - 1 - # 8 - 1-1/4"

80Y 80 1 3 - # 3 1 - # 3 1 - # 8 - 1-1/4"

80 80 1 3 - # 3 - 1 - # 8 - 1-1/4"

70Y 70 1 3 - # 4 1 - # 4 1 - # 8 - 1-1/4"

70 70 1 3 - # 4 - 1 - # 8 - 1-1/4"

60Y 60 1 3 - # 4 1 - # 4 1 - # 10 - 1-1/4"

60 60 1 3 - # 4 - 1 - # 10 - 1-1/4"

50Y 50 1 3 - # 6 1 - # 6 1 - # 10 - 1-1/4"

50 50 1 3 - # 6 - 1 - # 10 - 1"

45Y 45 1 3 - # 6 1 - # 6 1 - # 10 - 1"

45 45 1 3 - # 6 - 1 - # 10 - 1"

40Y 40 1 3 - # 8 1 - # 8 1 - # 10 - 1"

40 40 1 3 - # 8 - 1 - # 10 - 3/4"

35Y 35 1 3 - # 8 1 - # 8 1 - # 10 - 3/4"

35 35 1 3 - # 8 - 1 - # 10 - 3/4"

30Y 30 1 3 - # 10 1 - # 10 1 - # 10 - 3/4"

30 30 1 3 - # 10 - 1 - # 10 - 3/4"

20Y 20 1 3 - # 12 1 - # 12 1 - # 12 - 1/2"

20 20 1 3 - # 12 - 1 - # 12 - 1/2"

PHASE NEUTRAL EQ GND ISO GND

MARK AMPACITY

NO. OF

SETS

CONDUCTOR SIZES (AWG or KCMIL)

CONDUIT SIZE

COPPER BRANCH CIRCUIT & FEEDER SCHEDULE

KEYED NOTES

9.125 PROVIDE MULTI-PANEL DIGITAL METER TO MONITOR

INDIVIDUAL FEEDERS / CIRCUIT BREAKERS AS SHOWN.

PROVIDE DIGITAL METER ON FACE OF PANEL.

9.127 CLIN 001 UMMC ADDITION: PROVIDE 400A, WALL

MOUNTED, NEMA 3R COMBINATION MANUAL TRANSFER

SWITCH (DOUBLE THROW SWITCH) WITH CENTER OFF

POSITION. CABINET SHALL CONTAIN A FUSED MAIN,

PHASE ROTATION METER, AND SILVER PLATED COPPER

BUS WITH GENERATOR CAMLOCKS. UNDER CLIN 003, BID

OPTION 2, THIS EQUIPMENT DOES NOT GET FURNISHED,

INSTALLED, AND WIRED.

9.128 INSTALL CONDUITS UNDERGROUND INTO BASE OF

SERVICE ENTRANCE RATED CIRCUIT BREAKER.

COORDINATE SAW CUTTING OF EXISTING CONCRETE

SLAB WITH GENERAL CONTRACTOR.

9.301 PROVIDE 4#10, 1#10G IN 3/4"C BETWEEN PANELBOARD

AND SURGE PROTECTIVE DEVICE (SPD). MOUNT SPD

ADJACENT TO PANEL.

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

A

P R

1 W

2Q R

BA

_P la ns -0

ELECTORNIC TEXT SIGN

WITH THE FOLLOWING MESSAGES:

-ANNOUNCEMENT

-EVACUATE

M M M M M M M M M M

MMMMMMMM MM

M M M M M

M M MMMMMMMMMMMM

M M M M M M M M M M M M

MM

MM

SYSTEM INPUTS 1, 2, 3

US Army Corps of Engineers ®

G5

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

AP

R

W

2Q R

BA

_P la ns -0

CM

CM

GG

CM

CM

US Army Corps of Engineers ®

KEYED NOTES

5.301 PROVIDE A NEW FIRE ALARM CONTROL PANEL AND ASSOCIATED CONTROL PANEL EQUIPMENT AT THIS LOCATION.

5.302 PROVIDE A NEW FIRE ALARM RADIO TRANSCEIVER AND RADIO TRANSCEIVER ANTENNA. COORDINATE INSTALLATION OF THE

ANTENNA WITH STRUCTURAL SHEET S-121 KEYED NOTE 3.604.

5.303 PROVIDE WEATHERPROOF STROBE NOTIFICATION APPLIANCE ABOVE FIRE DEPARTMENT CONNECTION NEAR THIS LOCATION.

5.304 PROVIDE FIRE ALARM SYSTEM EQUIPMENT TO MONITOR ALL FIRE SPRINKLER SYSTEM VALVE TAMPER SWITCH AND FLOW SWITCH EQUIPMENT. COORDINATE QUANTITY OF MONITORING EQUIPMENT WITH FIRE SPRINKLER DETAIL B-2 ON SHEET F-500.

5.305 PROVIDE EQUIPMENT TO MONITOR TROUBLE AND ALARM SIGNALS FROM KITCHEN HOOD FIRE EXTINGUISHING SYSTEM

RELEASING PANEL.

5.306 PROVIDE NEW ANTENNA FOR THE NEW FIRE ALARM AND MASS NOTIFICATION SYSTEM. MOUNT THE ANTENNA SO THAT THE BASE OF THE ANTENNA IS LOCATED A MINIMUM OF THREE FEET ABOVE THE ROOF LEVEL. LOCATE THE ANTENNA AT THE EXTERIOR

WALL AT THIS LOCATION.

5.307 PROVIDE FIRE ALARM SYSTEM DUCT SMOKE DETECTOR. COORDINATE INSTALLATION WITH DIVISION 23. MECHANICAL SYSTEM CONTRACTOR SHALL CUT DUCTWORK AS REQUIRED TO MOUNT DUCT SMOKE DETECTOR. THE FIRE ALARM SYSTEM CONTRACTOR SHALL PROVIDE DIRECT SUPERVISION OF THE INSTALLATION OF THE DUCT SMOKE DETECTOR COMPONENTS AND CERTIFY IN WRITING THAT THE INSTALLATION WAS COMPLETE IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION REQUIREMENTS. THE FIRE ALARM CONTRACTOR SHALL WIRE THE CONTROL RELAY TO THE AIR HANDLING UNIT MOTOR CONTROL PANEL INTERFACE, FOR AIR HANDLING UNIT SHUTDOWN UPON SMOKE DETECTION, UNDER THE DIRECT SUPERVISION OF THE MECHANICAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL WITNESS AND CERTIFY IN WRITING THAT THE INSTALLATION WAS COMPLETE IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION REQUIREMENTS. THE FIRE ALARM CONTRACTOR SHALL WIRE THE FIRE ALARM SYSTEM TO THE DUCT SMOKE DETECTOR, CONTROL MODULE, AND DUCT DETECTOR REMOTE TEST STATION. LABEL EACH REMOTE TEST STATION WITH THE ASSOCIATED AIR HANDLING UNIT AS APPLICABLE.

5.308 PROVIDE AND LOCATE ALL DUCT SMOKE DETECTOR REMOTE TEST STATIONS NEAR THIS LOCATION. INSTALL IN A VISIBLE AND ACCESSIBLE LOCATION. MOUNT THE TOP OF THE DEVICE A MAXIMUM 48" ABOVE FINISHED FLOOR.

5.309 PROVIDE CONTROL MODULE TO RELEASE DOOR HOLDS AT THIS LOCATION UPON SMOKE DETECTOR FIRE ALARM SIGNAL.

5.310 PROVIDE EQUIPMENT TO INTEGRATE FIRE ALARM SYSTEM WITH SECURITY SYSTEM TO RELEASE SECURE DOORS UPON GENERAL FIRE ALARM. COORDINATE THE EXACT LOCATION OF THE EQUIPMENT WITH THE SECURITY SYSTEM CONTRACTOR.

DOORS SHALL BE FREE EGRESS FROM THE SPACE DURING AN EMERGENCY EVENT.

5.311 PROVIDE A LOCAL OPERATORS CONSOLE AND ANNUNCIATOR PANEL AT THIS LOCATION. MOUNT THE PANELS ADJACENT TO

EACH OTHER AT A MAXIMUM OF 48" ABOVE FINISHED FLOOR.

5.312 PROVIDE FIRE ALARM CONTROL MODULE TO INTEGRATE SYSTEM WITH EMERGENCY LIGHTING CONTROL EQUIPMENT TO OVERRIDE LIGHTING CONTROL DEVICES DURING A GENERAL FIRE ALARM CONDITION. REFERENCE ELECTRICAL SHEET E-121, NOTE 6, FOR ADDITIONAL INFORMATION.

5.313 PROVIDE EQUIPMENT TO INTEGRATE FIRE ALARM SYSTEM WITH ACCESS CONTROL PANEL TO RELEASE DOORS 110A AND 110B

UPON A FIRE ALARM SIGNAL.

5.314 SPACE RESERVED AT THIS LOCATION FOR NEW FIRE ALARM NOTIFICATION APPLIANCE POWER SUPPLY PANELS(S). PROVIDE A NEW NOTIFICATION APPLIANCE POWER SUPPLY PANEL(S) TO POWER NOTIFICATION APPLIANCE STROBES AND STROBES FOR

COMBINATION SPEAKER/STROBE APPLIANCES.

5.315 PROVIDE A SMOKE DETECTOR ABOVE THE FIRE ALARM CONTROL EQUIPMENT NEAR THIS LOCATION.

5.316 PROVIDE AND MOUNT MASS NOTIFICATION TEXTUAL SIGN ADJACENT TO THE EXIT SIGN AT THE SAME ELEVATION. INSTALL THE

SIGN SO THAT THE TOP OF THE SIGN IS AT THE SAME ELEVATION AS THE EXIT SIGN.

5.317 PROVIDE AN ADDRESSABLE SMOKE DETECTOR HEAD WITH SEPARATE SOUNDER BASE WITHIN EACH SLEEPING UNIT. SOUNDER BASE TO SHARE AN ADDRESS WITH THE SMOKE DETECTOR HEAD. SMOKE DETECTOR HEAD MUST BE ATTACHED TO THE SOUNDER BASE. THE ALARM CONTROL PANEL SHALL BE PROGRAMMED TO INITIATE A BUILDING WIDE ALARM UPON SMOKE DETECTION OF TWO SEPARATE SLEEPING UNIT SMOKE DETECTORS. SEE FIRE ALARM MATRIX ON SHEET F-501 DETAILS - FIRE

ALARM.

5.318 PROVIDE A MONITOR MODULE TO MONITOR THE HVAC EMERGENCY SHUTDOWN BUTTON NEAR THIS LOCATION.

5.319 PROVIDE CONTROL MODULE (RELAY) FOR EACH TRANSCEIVER ZONE. TRANSCEIVER MUST HAVE A MINIMUM OF 20 ZONES FOR FIELD PROGRAMMING BY THE FIRE ALARM CONTRACTOR AND BEALE AFB ALARM SHOP. REFERENCE SHEET F-501 - DETAILS -

FIRE ALARM FOR ADDITIONAL INFORMATION.

5.320 PROVIDE SILENT TEST CONTROL MODULES, LED LIGHTS, SPEAKERS, SPEAKER STROBE, END OF LINE RELAYS, MONITOR MODULE, AND KEYED REMOTE TEST STATION AT THIS NEAR THIS LOCATION IN A VERTICAL AND LINEAR CONFIGURATION TO FIT WITHIN THE AVAILABLE SPACE AND ACCESSIBLE TO BEALE AFB ALARM PERSONNEL FOR FUTURE TESTING. PROVIDE PROVISIONS FOR UP TO FOUR STROBE TEST CIRCUITS, TWO SPEAKER CIRCUITS, AND TWO TEXTUAL SIGN CIRCUIT. REFERENCE SHEET F-501 -

DETAILS - FIRE ALARM FOR ADDITIONAL INFORMATION.

5.321 PROVIDE FIRE ALARM RELAY TO DEACTIVATE NEAREST ADJACENT SPEAKER TO THE LOCAL OPERATORS CONSOLE OR FIRE ALARM AND MASS NOTIFICATION SYSTEM TO PREVENT INTERFERENCE WITH THE HAND-HELD MICROPHONE WHEN MAKING

ANNOUNCEMENTS.

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

A

PR

W

2Q R

BA

_P la ns -0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 3 5 7 9

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

FI

LE

N U

M

BE

R

2 4 6 8 10 11 12 13 14 15 16 17 18 19 20

B

A

C

D

E

F

G

H

J

K

L

M

N

P

Fi le

P at h:

Pl ot D at e:

C :\R ev it

Lo ca l\2

4.

-P

-R

_s te ve .w in ne tt.

rv t 4/

/2

3:

:1

PM

P-601

SC

H

ED

U

LE

S

- F

IX

TU

R

ES

BE

AL

E

AI

R F

O R

C E

BA

SE

, C

AL

IF

O

R N

IA

LO

U

IS

VI

LL

E D

IS

TR

IC

T

M

AR

TI

N

L U

TH

ER

K

IN

G P

L

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

J.

TI

ED

E

J.

TI

ED

E

M .H

ER

M

AN

J.

W

IL

SO

N

AU

G

U

ST

1, M H

P R

O

JE

C T

N O

0t h

AR

W A

IR

C

R

EW

R

EA

D

IN

ES

S

FA

C

IL

IT

Y R

EN

O

VA

TI

O N

A

D D

IT

IO

N

PR

O

JE

C T

N O

BA

EY

C A

BA

EY

C B

0-

.0

.0

1- P-

R

P2

C

ER

TI

FI

ED

F

IN

AL

(1

) D

ES

IG

N S

U

BM

IT

TA

L

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

A

PR

W

2Q R

BA

_P la ns -0

Beale_AD101_Amend001_250416
Beale_E-002_Amend001_250416
Beale_E-101_Amend001_250416
Beale_E-401_Amend001_250416
Beale_E-701_Amend001_250416
Beale_F-501_Amend001_250416
Beale_FA-102_Amend001_250416
Beale_P-601_Amend001_250416

File details come from the government source that posted it. Updated .