W912QR25B0001_Plans-0002.pdf

PDF 36 MB Posted

Attached to
Construction of an Indoor Small Arms Range (ISAR) located in Grissom Air Reserve Base, IN.
Solicitation number
W912QR25B0001
Issued by

About this file

This file contains architectural, structural, mechanical, and electrical drawings and specifications for the construction of an Indoor Small Arms Range (ISAR) at Grissom Air Reserve Base in Indiana. The drawings detail a shooting range facility that includes firing lanes, bullet trap areas, control booth, weapons cleaning room, mechanical/electrical rooms, restrooms, and support spaces. The facility will incorporate specialized ventilation systems designed to maintain negative air pressure in the range area, specialized acoustic treatments, ballistic-rated materials, and safety features like overhead baffles and safety ceilings.

Key technical requirements include: specialized HVAC systems with 100% outside air for the range area maintaining 75 FPM (+/- 5%) airflow at firing positions, radial air diffusers, three-stage HEPA filtration for exhaust, dedicated mechanical rooms for range and building systems, seismic and blast design considerations, and integration with base-wide building automation systems. The electrical system includes emergency shutoff capabilities, specialized lighting, and power distribution for range equipment. The drawings provide detailed specifications for construction methods, materials, and equipment to be used throughout the facility's systems and components. This is part of solicitation W912QR25B0001 being managed by the US Army Corps of Engineers Louisville District.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Pl ot

D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

. P

LA

C E

LO

U

IS

VI

LL

E, K Y

G R

IS

SO

M A

IR

R

ES

ER

VE

B

AS

E

IN

D

O O

R S

M

AL

L

AR

M S

R

AN

G E

PN

C

TG

B1

2, P

, F Y

Fi le

P at h:

SE

PT

EM

BE

R

C

ER

TI

FI

ED

F

IN

AL

2/

/2

3:

:2

PM

C

:\U se rs \h

2e dd ra h\

D oc um en ts \5

9_ v2

2_

SI

TE

_I

SA

R _h

2e dd ra h.

rv t

G-002

SH

EE

T

IN

D

EX

J.

M

AC

M

IL

LA

N

R .H

O O

E

D .B

AN

JA

N O

VI

C

INDEX

SHEET NUMBER SHEET NAME

GENERAL

G-001 COVER SHEET

G-002 SHEET INDEX

G-003 SITE AREA, LOCATION, AND VICINITY MAP

G-004 CONTRACTOR HAUL ROUTE

LIFE SAFETY

X-001 LIFE SAFETY CODE REVIEW

X-101 CIVIL LIFE SAFETY PLAN

X-110 COMPREHENSIVE FIRST FLOOR LIFE SAFETY PLAN

SURVEY MAPPING

VA101 SITE ARIAL IMAGERY

VF101 SITE FIELD SURVEY

VF401 SITE CONTROL POINTS

GEOTECHNICAL

BB101 BORING LOCATION PLAN

BB501 SOIL AND ROCK CLASSIFICATION

BB502 BORING LOGS

BB503 BORING LOGS

BB504 BORING LOGS

EROSION CONTROL

GC101 OVERALL EROSION CONTROL PLAN

GC102 EROSION CONTROL PLAN

GC103 EROSION CONTROL PLAN

GC104 EROSION CONTROL PLAN

GC105 EROSION CONTROL PLAN

GC106 EROSION CONTROL PLAN

GC107 EROSION CONTROL PLAN

GC108 EROSION CONTROL PLAN

GC109 EROSION CONTROL PLAN

GC501 EROSION CONTROL DETAILS

GC502 EROSION CONTROL DETAILS

GC503 EROSION CONTROL DETAILS

DEMOLITION

CD101 OVERALL DEMOLITION PLAN

CD102 DEMOLITION PLAN

CD103 DEMOLITION PLAN

CD104 DEMOLITION PLAN

CD105 DEMOLITION PLAN

CD106 DEMOLITION PLAN

CD107 DEMOLITION PLAN

CD108 DEMOLITION PLAN

CD109 DEMOLITION PLAN

CD110 DEMOLITION PLAN

CD111 DEMOLITION PLAN

SITE PLAN

CS101 OVERALL CIVIL SITE PLAN

CS102 CIVIL SITE PLAN

CS103 CIVIL SITE PLAN

CS104 CIVIL SITE PLAN

CS105 CIVIL SITE PLAN

CS106 CIVIL SITE PLAN

CS107 CIVIL SITE PLAN

CS108 CIVIL SITE PLAN

CS201 ACCESS ROAD PROFILE

CS202 ACCESS ROAD PROFILE

CS203 ACCESS ROAD PROFILE

CS204 ACCESS ROAD PROFILE

CS501 CIVIL SITE DETAILS

CS502 CIVIL SITE DETAILS

CS503 CIVIL SITE DETAILS

GRADING PLAN

CG101 OVERALL GRADING PLAN

CG102 GRADING PLAN

CG103 GRADING PLAN

CG104 GRADING PLAN

CG201 STORM SEWER PROFILES

CG501 GRADING DETAILS

CG502 GRADING DETAILS

CG503 GRADING DETAILS

CG504 GRADING DETAILS

CG505 GRADING DETAILS

UTILITY PLAN

CU101 OVERALL UTILITY PLAN

CU102 UTILITY PLAN

CU103 UTILITY PLAN

CU104 UTILITY PLAN

CU105 UTILITY PLAN

CU106 UTILITY PLAN

CU107 UTILITY PLAN

CU108 UTILITY PLAN

CU109 UTILITY PLAN

CU110 UTILITY PLAN

CU111 UTILITY PLAN

CU201 SANITARY SEWER PROFILE

CU202 SANITARY SEWER PROFILE

CU203 SANITARY SEWER PROFILE

CU501 UTILITY DETAILS

CU502 UTILITY DETAILS

ELECTRICAL SITE

ES001 ELECTRICAL SITE LEGEND

ES101 ELECTRICAL SITE PLAN

ES102 ELECTRICAL SITE PLAN

ES103 ELECTRICAL SITE PLAN

ES104 ELECTRICAL SITE PLAN

ES105 ELECTRICAL SITE PLAN

ES501 ELECTRICAL SITE DETAILS

STRUCTURAL

S-001 GENERAL STRUCTURAL NOTES

S-002 GENERAL STRUCTURAL NOTES

S-003 COMPONENETS & CLADDING WIND LOAD DIAGRAM

S-004 ISOMETRIC VIEW

S-101 FOUNDATION PLAN - COMPREHENSIVE

S-102 FOUNDATION PLAN - AREA A

S-103 FOUNDATION PLAN - AREA B

INDEX

SHEET NUMBER SHEET NAME

S-111 ROOF FRAMING PLAN - COMPREHENSIVE

S-112 ROOF FRAMING PLAN - AREA A

S-113 ROOF FRAMING PLAN - AREA B

S-301 FOUNDATION DETAILS

S-302 FOUNDATION DETAILS

S-303 FOUNDATION DETAILS

S-304 FOUNDATION DETAILS

S-401 FRAMING DETAILS

S-402 FRAMING DETAILS

S-403 FRAMING DETAILS

S-404 FRAMING DETAILS

S-405 FRAMING DETAILS

S-406 FRAMING DETAILS

S-408 BRACED FRAME CONNECTIONS

S-501 BRACED FRAME ELEVATIONS

S-502 ELEVATION VIEWS

S-503 LOUVER SUPPORT ELEVATION

ARCHITECTURAL

A-001 ABBREVIATIONS, DRAWING ANNOTATIONS AND SYMBOL LEGEND

A-002 ABA ACCESSIBILITY GUIDELINES (FOR REFERENCE ONLY)

A-003 SEALANT, MASONRY JOINTS & MISC. STANDARD DETAILS

A-110 COMPREHENSIVE FIRST FLOOR PLAN

A-111 FIRST FLOOR ANNOTATION PLAN - AREA A

A-112 FIRST FLOOR ANNOTATION PLAN - AREA B

A-113 FIRST FLOOR DIMENSION PLAN - AREA A

A-114 FIRST FLOOR DIMENSION PLAN - AREA B

A-130 COMPREHENSIVE ROOF PLAN

A-140 FIRST FLOOR REFLECTED CEILING PLAN - COMPREHENSIVE

A-141 FIRST FLOOR REFLECTED CEILING PLAN - AREA A

A-142 FIRST FLOOR REFLECTED CEILING PLAN - AREA B

A-201 EXTERIOR ELEVATIONS

A-202 EXTERIOR ELEVATIONS

A-203 EXTERIOR ELEVATIONS

A-301 BUILDING SECTIONS

A-302 BUILDING SECTIONS

A-311 WALL SECTIONS

A-312 WALL SECTIONS

A-313 SECTION AT FIRING RANGE

A-314 ENTRANCE WALL DETAILS

A-315 ENTRANCE WALL DETAILS

A-401 ENLARGED PLAN - RESTROOMS

A-402 ENLARGED PLAN - CONTROL BOOTH

A-501 PLAN DETAILS

A-511 SECTION DETAILS

A-512 SECTION DETAILS

A-521 ROOF DETAILS

A-601 PARTITION SCHEDULE AND DETAILS

A-602 DEMISING WALL DETAILS

A-611 DOOR SCHEDULE, TYPES, AND DETAILS

A-612 DOOR AND WINDOW DETAILS - EXTERIOR

A-613 DOOR AND WINDOW DETAILS - EXTERIOR

A-614 DOOR DETAILS - INTERIOR

A-615 MISC. DETAILS

A-621 WINDOW SCHEDULE, TYPES, AND DETAILS

A-622 LOUVER ELEVATIONS AND DETAILS

A-631 RANGE STRIPING AND EQUIPMENT

INTERIORS

I-501 INTERIOR FINISH DETAILS

I-601 INTERIOR ROOM, COLOR AND MATERIAL FINISH SCHEDULE AND DETAILS

IG110 COMPREHENSIVE SIGNAGE PLAN

IG601 SIGNAGE SCHEDULE & SIGNAGE DETAILS

FIRE ALARM

FA001 FIRE ALARM LEGEND

FA101 FIRE ALARM & MASS NOTIFICATION PLAN - COMPREHENSIVE

FA102 FIRE ALARM & MASS NOTIFICATION PLAN - AREA A

FA103 FIRE ALARM & MASS NOTIFICATION PLAN - AREA B

FA701 FIRE ALARM / MASS NOTIFICATION RISER DIAGRAM & SYSTEM MATRIX

FIRE PROTECTION

FP101 FIRE PROTECTION FLOOR PLAN - COMPOSITE

FP401 ENLARGED FIRE PROTECTION RISER & PLAN

PLUMBING

P-001 PLUMBING LEGEND

P-101 FLOOR PLAN - DOMESTIC HOT AND COLD PIPING - COMPOSITE

P-102 FLOOR PLAN - DOMESTIC HOT AND COLD PIPING - AREA B

P-103 FLOOR PLAN - WASTE AND VENT PIPING - AREA B

P-104 FLOOR PLAN - RADON PIPING - AREA B

P-105 FLOOR PLAN - NATURAL GAS PIPING - AREA B

P-106 FLOOR PLAN - COMPRESSED AIR - COMPOSITE

P-301 PLUMBING SECTIONS

P-401 ENLARGED MECH ROOM 113 - FLOOR PLAN

P-402 ENLARGED MECH ROOM 112 - FLOOR PLAN

P-403 ENLARGED RESTROOMS - WASTE AND VENT

P-404 ENLARGED RESTROOMS - DOMESTIC HOT AND COLD PIPING

P-501 PLUMBING DETAILS

P-502 PLUMBING DETAILS

P-503 PLUMBING DETAILS

P-504 PLUMBING DETAILS

P-601 PLUMBING SCHEDULES

MECHANICAL

M-001 MECHANICAL GENERAL NOTES, ABBREVIATIONS

M-002 MECHANICAL LEGEND AND NOTES

M-101 HVAC PLAN

M-102 PARTIAL HVAC PLAN - AREA A

M-103 PARTIAL HVAC PLAN - AREA B

M-301 HVAC BUILDING SECTION

M-302 HVAC BUILDING SECTION

M-401 HVAC ENLARGED MECHANICAL ROOM PLANS

M-402 HVAC ENLARGED MECHANICAL ROOM SECTIONS

M-403 ISOMETRIC VIEW - MECHANICAL ROOM 112

M-404 ISOMETRIC VIEW - MECHANICAL ROOM 113

M-405 HVAC ISOMETRIC VIEW - AREA B

M-406 HVAC ISOMETRIC VIEW - RANGE SUPPLY DUCT PLAN

M-407 HVAC ISOMETRIC VIEW - RANGE EXHAUST DUCT PLAN

M-408 DUST COLLECTION UNIT DETAILS

INDEX

SHEET NUMBER SHEET NAME

M-501 HVAC DETAILS

M-502 HVAC DETAILS

M-503 HVAC DETAILS

M-601 HVAC SCHEDULES

M-602 HVAC SCHEDULES

M-603 HVAC SCHEDULES

M-700 CONTROLS LEGEND

M-701 HVAC CONTROL POINT SCHEDULE INSTRUCTION

M-702 HVAC CONTROL SCHEDULING AND ALARM SEQUENCING

M-703 HVAC CONTROL SYSTEM NETWORK

M-704 HVAC CONTROL SYSTEM NETWORK

M-705A RANGE VENITLATION HVU & EF CONTROL SCEHMATIC

M-705B RANGE VENTILATION RMCP CRITERA & SEQUENCE OF OPERATION

M-705C RANGE VENTILATION LADDER DIAGRAMS

M-705D RANGE VENTILATION POINTS SCHEDULE

M-706A DEDICATED OUTDOOR AIR UNIT DOAS-1 CONTROL SCHEMATIC

M-706B DEDICATED OUTDOOR AIR UNIT DOAS-1 LADDER DIAGRAMS

M-706C DEDICATED OUTDOOR AIR UNIT DOAS-1 SEQUENCE OF OPERATION

M-706F DEDICATED OUTDOOR AIR UNIT DOAS-1 POINTS SCHEDULE

M-707A AIR HANDLING UNIT AHU CONTROL SCHEMATIC

M-707B AIR HANDLING UNIT AHU SEQUENCE OF OPERATION, LADDER DIAGRAM, AND POINTS

SCHEDULE

M-708 ENERGY RECOVERY UNIT ERU-1 CONTROL SCHEMATIC, LADDER DIAGRAM, SEQUENCE OF

OPERATION AND POINTS SCHEDULE

M-709 ELECTRIC UNIT HEATER CONTROLS

M-710 DUCTLESS SPLIT SYSTEM AIR CONDITIONER CONTROLS

M-721 ENERGY AND WATER MONITORING SCHEMATICS AND POINTS LIST

M-722 ENERGY MONITORING LOGIC DIAGRAMS

MP101 HVAC PARTIAL PIPING PLAN - AREA B

ELECTRICAL

E-001 LEGEND AND ABBREVIATIONS

E-101 LIGHTING PLAN - COMPREHENSIVE

E-102 LIGHTING PLAN - AREA A

E-103 LIGHTING PLAN - AREA B

E-110 POWER PLAN - COMPREHENSIVE

E-111 POWER PLAN - AREA A

E-112 POWER PLAN - AREA B

E-120 MECHANICAL POWER PLAN - COMPREHENSIVE

E-121 MECHANICAL POWER PLAN - AREA A

E-122 MECHANICAL POWER PLAN - AREA B

E-140 LIGHTNING PROTECTION PLAN - COMPREHENSIVE

E-401 ENLARGED PLAN

E-501 LIGHTING SCHEDULES & DETAILS

E-502 LIGHTING DETAILS

E-503 ELECTRICAL DETAILS

E-504 ELECTRICAL DETAILS

E-505 ELECTRICAL DETAILS

E-506 ELECTRICAL DETAILS

E-507 LIGHTNING PROTECTION DETAILS

E-601 ONE-LINE DIAGRAM

E-602 PANEL SCHEDULES

E-603 PANEL SCHEDULES

E-701 ELECTRICAL SCHEDULES

TELECOMMUNICATIONS

T-001 TELECOMMUNICATIONS SYSTEMS LEGEND

T-101 TELECOM PLAN - COMPREHENSIVE

T-102 TELECOM PLAN - AREA A

T-103 TELECOM PLAN - AREA B

T-501 SYSTEMS DETAILS

T-502 SYSTEMS DETAILS

T-503 SYSTEMS DETAILS

T-601 SYSTEMS RISERS

Grand total: 249

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

F

EB

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

F

EB

W

2Q R

B0

1_

Pl an s-

MATCHLINE - SEE SHEET CD104

- SEE SHEET CD106

MATCHLINE - SEE SHEET CD106

- SEE SHEET CD108

W

W W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SAN

SAN

SAN

SAN

SAN

G G

G G

G G

G G

G G

G G

G G

G G

G

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

SD

SD

SD

SD

SD

SD

SD SD SD SD SD SD SD SD

SD

SD

SD

SD

SD

SD

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

W W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SAN

SAN

SAN

SAN

SAN

G G

G G

G G

G G

G G

G G

G G

G G

G

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

SD

SD

SD

SD

SD

SD

SD SD SD SD SD SD SD SD

SD

SD

SD

SD

SD

SD

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

N: 1971742.7995 E: 191940.5358

N: 1971660.2361 E: 191940.5239

N: 1971660.0969 E: 192023.9787

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SHEET ID

T.

S

M

IT

H

T.

F

R O

ST

C . C

AR

TE

R

J.

M

AC

M

IL

LA

N

O F

D

EM

O

LI

TI

O

N P

LA

CD106

of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

. P L.

LO

U

IS

VI

LL

E, K Y

SE

PT

EM

BE

R

AN

SI

D

G

IS

SO

M A

IR

R

ES

ER

VE

B

AS

E

IN

D

O O

R S

M

AL

L

AR

M S

R

AN

G E

PN

C

TG

B1

2-

, P

, F Y

C

ER

TI

FI

ED

F

IN

AL

1. CONTRACTOR TO COORDINATE DEMOLITION ACTIVITIES WITH

CONTRACTING OFFICER'S REPRESENTATIVE (COR) AND BASE PERSONNEL

IN ORDER TO ENSURE CONSTRUCTION ACTIVITIES DO NOT INTERFERE

WITH BASE ACTIVITIES.

2. CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES PRIOR TO ANY

CONSTRUCTION ACTIVITY.

3. EXISTING UTILITIES AND SITE STRUCTURES NOT IDENTIFIED FOR

DEMOLITION MUST BE PROTECTED DURING DEMOLITION AND

CONSTRUCTION.

4. DEMOLITION OF EXISTING SMALL ARMS RANGE FACILITY IS NOT TO OCCUR

UNTIL NEW RANGE FACILITY IS CONSTRUCTED AND TURNED OVER TO BASE

FOR OPERATIONS.

GENERAL SHEET NOTES

SHEET KEYNOTES

1. CONTRACTOR TO DEMOLISH EXISTING SMALL ARMS RANGE FENCE AND

GATE. IF GATE LOCK IS STILL PRESENT ON FENCE, CONTRACTOR TO

COORDINATE WITH COR TO RETURN LOCK TO PROPER BASE PERSONNEL.

2. CONTRACTOR TO DEMOLISH EXISTING UTILITIES ACCORDING TO

SPECIFICATION 02 41 00. COORDINATE WITH COR TO ENSURE BASE

PERSONNEL HAVE REMOVED ALL ITEMS FROM THE EXISTING FACILITY AND

HAVE FULLY OCCUPIED THE PROPOSED FACILITY. IF EXISTING UTILITIES ARE

EXCAVATED THEN THE CONTRACTOR MUST BACKFILL AND GRADE UTILITY

TRENCH TO EXISTING GROUND ELEVATIONS. THE CONTRACTOR MUST THEN

PERMANENTLY SEED DISTURBED GROUND. EXISTING UTILITIES ARE SHOWN

IN THE PLANS AND ADDITIONAL UTILITIES ARE SHOWN IN THE EXISTING

SMALL ARMS FACILITY SITE DETAILS ON SHEETS CD501 AND CD502. EXISTING

UTILITIES ARE TO BE DEMOLISHED ACCORDING TO PLAN SHEETS OR 10 FEET

FROM THE EXISTING FACILITY IF THE DEMOLITION EXTENT IS NOT SHOWN.

ALL UTILITIES DEMOLISHED MUST BE WATERTIGHT SEALED AND CAPPED. THE

CONTRACTOR MUST NOTIFY ALL UTILITY OWNER/OPERATORS MORE THAN 14

DAYS PRIOR TO DEMOLITION TO ENSURE SERVICES ARE NOT ACTIVE AT THE

TIME OF DEMOLITION.

3. DEMOLISH EXISTING SMALL ARMS RANGE FACILITY AND ADJACENT

SUPPORTING STRUCTURES. DEMOLITION INCLUDES THE EXISTING FACILITY

VERTICAL STRUCTURE, BUILDING PAD, AND FOUNDATION STRUCTURES.

CONTRACTOR TO USE TOPSOIL FROM PROPOSED RANGE SITE TO FILL THE

EXCAVATED FOUNDATION AREA. GRADE TO DRAIN TO EXISTING DRAINAGE

SYSTEMS. THE CONTRACTOR MUST THEN PERMANENTLY SEED DISTURBED

GROUND. SEE SHEETS REFERENCE PROJECT SHEETS FOR INFORMATION ON

EXISTING SMALL ARMS RANGE.

4. DEMOLISH EXISTING GRAVEL TRAIL AT INDICATED LOCATION. REMOVE

AGGREGATE AS NECESSARY TO GRADE FOR PROPOSED FACILITY AND

SUPPORTING STRUCTURES.

5. REMOVE EXISTING TREES TO BE REPLACED WITH LIKE KIND BASED ON

SPECIFICATION 32 93 00. SEE CIVIL SITE (CS) SERIES SHEETS FOR LOCATIONS

OF NEW TREES.

6. EXISTING RANGE ROAD TO REMAIN. CONTRACTOR TO TAKE NOTE OF

EXISTING CONDITION AND MAINTAIN DURING DEMOLITION.

7. EXISTING CURB AND GUTTER TO BE REMOVED TO TIE IN PROPOSED DRIVE TO

EXISTING PARKING AREA FOR EDGE KEY.

8. EXISTING FOOT GOLF HOLE TO BE RELOCATED. SEE LOCATION ON SHEET

CS105.

9. EXISTING FOOTGOLF HOLE TO BE TEMPORARILY REMOVED DURING

CONSTRUCTION. ONCE CONSTRUCTION IS COMPLETE, FOOTGOLF HOLE IS TO

BE REPLACED IN LOCATION ACCORDING TO SITE PLANS.

10. CURB AND GUTTER REMOVAL FOR PROPOSED CONSTRUCTION ENTRANCE TO

BE REPLACED TO EXISTING GRADE BY CONTRACTOR ONCE PROJECT IS

STABILIZED AND CONSTRUCTION ENTRANCE IS NO LONGER NEEDED.

11. EXPLOSIVE SAFETY QUANTITY DISTANCE (ESQD) FROM THE EXISTING

MUNITIONS STORAGE FACILITY TO THE WEST OF THE PROJECT. IF WORKING

WITHIN THE ESQD, CONTRACTOR MUST NOTIFY COR TO COORDINATE

CONSTRUCTION ACTIVITIES.

12. CONTRACTOR TO PROTECT TREES TO REMAIN ACCORDING TO DETAIL J13

SHEET GC501.

13. REMOVE EXISTING CATCH BASIN STRUCTURE.

14. REMOVE EXISTING 10 INCH CORRUGATED PE PIPE.

15. REMOVE AND REPLACE EXISTING SIGNS.

16. REMOVE AND REPLACE ASPHALT AND CURB DURING UTILITY CONSTRUCTION.

REPLACEMENT ASPHALT AND CURB MUST MATCH EXISTING PAVEMENT

SECTION, CURB TYPE, ELEVATIONS, AND GRADES. NO CURB ON EXISTING

SMALL ARMS RANGE ENTRANCE, CONTRACTOR TO REPLACE WITH MATCHING

PAVEMENT SECTION AND ELEVATIONS TO EXISTING DRIVE.

LEGEND

PROPOSED STRUCTURE AND PAVEMENT REMOVAL

PROPOSED LINEAR REMOVAL

PROPOSED TREE OR SHRUB REMOVAL

PROPOSED CONTRACTOR WORK LIMITS

_1

_1

_2

_2

A1 SCALE: 1"=20'

DEMOLITION PLAN

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

F

EB

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

FE

B

W

2Q R

B0

1_

Pl an s-

MATCHLINE - SEE SHEET CD105

- SEE SHEET CD107

ESQD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

N: 1971438.4105 E: 191345.1722

N: 1971438.3012 E: 191309.4038

N: 1971371.6171 E: 191309.4038 N: 1971352.3657

E: 191696.9946

N: 1971257.1385 E: 191696.9946

N: 1971352.3662 E: 191576.5819

N: 1971371.6171 E: 191576.0795

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SHEET ID

T.

S

M

IT

H

T.

F

R O

ST

C . C

AR

TE

R

J.

M

AC

M

IL

O F

D

EM

O

LI

TI

O

N P

LA

CD107

of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

. P L.

LO

U

IS

VI

LL

E, K Y

SE

PT

EM

BE

R

IS

SO

M A

IR

R

ES

ER

VE

B

AS

E

IN

D

O O

R S

M

AL

L

AR

M S

R

AN

G E

PN

C

TG

B1

2-

, P

, F

TI

FI

ED

F

IN

AL

1. CONTRACTOR TO COORDINATE DEMOLITION ACTIVITIES WITH

CONTRACTING OFFICER'S REPRESENTATIVE (COR) AND BASE PERSONNEL

IN ORDER TO ENSURE CONSTRUCTION ACTIVITIES DO NOT INTERFERE

WITH BASE ACTIVITIES.

2. CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES PRIOR TO ANY

CONSTRUCTION ACTIVITY.

3. EXISTING UTILITIES AND SITE STRUCTURES NOT IDENTIFIED FOR

DEMOLITION MUST BE PROTECTED DURING DEMOLITION AND

CONSTRUCTION.

4. DEMOLITION OF EXISTING SMALL ARMS RANGE FACILITY IS NOT TO OCCUR

UNTIL NEW RANGE FACILITY IS CONSTRUCTED AND TURNED OVER TO BASE

FOR OPERATIONS.

GENERAL SHEET NOTES

SHEET KEYNOTES

1. CONTRACTOR TO DEMOLISH EXISTING SMALL ARMS RANGE FENCE AND

GATE. IF GATE LOCK IS STILL PRESENT ON FENCE, CONTRACTOR TO

COORDINATE WITH COR TO RETURN LOCK TO PROPER BASE PERSONNEL.

2. CONTRACTOR TO DEMOLISH EXISTING UTILITIES ACCORDING TO

SPECIFICATION 02 41 00. COORDINATE WITH COR TO ENSURE BASE

PERSONNEL HAVE REMOVED ALL ITEMS FROM THE EXISTING FACILITY AND

HAVE FULLY OCCUPIED THE PROPOSED FACILITY. IF EXISTING UTILITIES ARE

EXCAVATED THEN THE CONTRACTOR MUST BACKFILL AND GRADE UTILITY

TRENCH TO EXISTING GROUND ELEVATIONS. THE CONTRACTOR MUST THEN

PERMANENTLY SEED DISTURBED GROUND. EXISTING UTILITIES ARE SHOWN

IN THE PLANS AND ADDITIONAL UTILITIES ARE SHOWN IN THE EXISTING

SMALL ARMS FACILITY SITE DETAILS ON SHEETS CD501 AND CD502. EXISTING

UTILITIES ARE TO BE DEMOLISHED ACCORDING TO PLAN SHEETS OR 10 FEET

FROM THE EXISTING FACILITY IF THE DEMOLITION EXTENT IS NOT SHOWN.

ALL UTILITIES DEMOLISHED MUST BE WATERTIGHT SEALED AND CAPPED. THE

CONTRACTOR MUST NOTIFY ALL UTILITY OWNER/OPERATORS MORE THAN 14

DAYS PRIOR TO DEMOLITION TO ENSURE SERVICES ARE NOT ACTIVE AT THE

TIME OF DEMOLITION.

3. DEMOLISH EXISTING SMALL ARMS RANGE FACILITY AND ADJACENT

SUPPORTING STRUCTURES. DEMOLITION INCLUDES THE EXISTING FACILITY

VERTICAL STRUCTURE, BUILDING PAD, AND FOUNDATION STRUCTURES.

CONTRACTOR TO USE TOPSOIL FROM PROPOSED RANGE SITE TO FILL THE

EXCAVATED FOUNDATION AREA. GRADE TO DRAIN TO EXISTING DRAINAGE

SYSTEMS. THE CONTRACTOR MUST THEN PERMANENTLY SEED DISTURBED

GROUND. SEE SHEETS REFERENCE PROJECT SHEETS FOR INFORMATION ON

EXISTING SMALL ARMS RANGE.

4. DEMOLISH EXISTING GRAVEL TRAIL AT INDICATED LOCATION. REMOVE

AGGREGATE AS NECESSARY TO GRADE FOR PROPOSED FACILITY AND

SUPPORTING STRUCTURES.

5. REMOVE EXISTING TREES TO BE REPLACED WITH LIKE KIND BASED ON

SPECIFICATION 32 93 00. SEE CIVIL SITE (CS) SERIES SHEETS FOR LOCATIONS

OF NEW TREES.

6. EXISTING RANGE ROAD TO REMAIN. CONTRACTOR TO TAKE NOTE OF

EXISTING CONDITION AND MAINTAIN DURING DEMOLITION.

7. EXISTING CURB AND GUTTER TO BE REMOVED TO TIE IN PROPOSED DRIVE TO

EXISTING PARKING AREA FOR EDGE KEY.

8. EXISTING FOOT GOLF HOLE TO BE RELOCATED. SEE LOCATION ON SHEET

CS105.

9. EXISTING FOOTGOLF HOLE TO BE TEMPORARILY REMOVED DURING

CONSTRUCTION. ONCE CONSTRUCTION IS COMPLETE, FOOTGOLF HOLE IS TO

BE REPLACED IN LOCATION ACCORDING TO SITE PLANS.

10. CURB AND GUTTER REMOVAL FOR PROPOSED CONSTRUCTION ENTRANCE TO

BE REPLACED TO EXISTING GRADE BY CONTRACTOR ONCE PROJECT IS

STABILIZED AND CONSTRUCTION ENTRANCE IS NO LONGER NEEDED.

11. EXPLOSIVE SAFETY QUANTITY DISTANCE (ESQD) FROM THE EXISTING

MUNITIONS STORAGE FACILITY TO THE WEST OF THE PROJECT. IF WORKING

WITHIN THE ESQD, CONTRACTOR MUST NOTIFY COR TO COORDINATE

CONSTRUCTION ACTIVITIES.

12. CONTRACTOR TO PROTECT TREES TO REMAIN ACCORDING TO DETAIL J13

SHEET GC501.

13. REMOVE EXISTING CATCH BASIN STRUCTURE.

14. REMOVE EXISTING 10 INCH CORRUGATED PE PIPE.

15. REMOVE AND REPLACE EXISTING SIGNS.

16. REMOVE AND REPLACE ASPHALT AND CURB DURING UTILITY CONSTRUCTION.

REPLACEMENT ASPHALT AND CURB MUST MATCH EXISTING PAVEMENT

SECTION, CURB TYPE, ELEVATIONS, AND GRADES. NO CURB ON EXISTING

SMALL ARMS RANGE ENTRANCE, CONTRACTOR TO REPLACE WITH MATCHING

PAVEMENT SECTION AND ELEVATIONS TO EXISTING DRIVE.

LEGEND

PROPOSED STRUCTURE AND PAVEMENT REMOVAL

PROPOSED LINEAR REMOVAL

PROPOSED TREE OR SHRUB REMOVAL

PROPOSED CONTRACTOR WORK LIMITS

_1

_1

_2

_2

A1 SCALE: 1"=20'

DEMOLITION PLAN

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

FE

B

R

EV

IS

ED

IN

A

C C

O R

D

AN

C E

W

IT

H A

M

EN

D M

EN

T

F

EB

W

2Q R

B0

1_

Pl an s-

MATCHLINE - SEE SHEET CD106

- SEE SHEET CD108

MATCHLINE - SEE SHEET CD108

- SEE SHEET CD109

SD SD

EX. 18" CMP

INV. = 791.03

WWW

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

SAN SAN SAN SAN SAN SAN SAN SAN SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

G G

G G

G G

G G G G G G

G

E

E

E

E

E

E

E

E

E E

E E

E E

E E

E E

E E

E E

E E

E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E

SD

SD SD SD SD SD

SD

SD

SD

SD

SD

SD

SD

SD

SDSD SD SD SD

WWWWWWW

W W

W

W W

W W

W W

W W

W

EX. LIGHT POLE

N: 1971257.1385 E: 191981.9203

N: 1971193.1325 E: 192027.9072

N: 1971203.1316 E: 192027.9203

N: 1971433.4290 E: 192027.9203

N: 1971433.4290 E: 192024.0203

WWW

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

SAN SAN SAN SAN SAN SAN SAN SAN SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

G G

G G

G G

G G G G G G

G

E

E

E

E

E

E

E

E

E E

E E

E E

E E

E E

E E

E E

E E

E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E

SD

SD SD SD SD SD

SD

SD

SD

SD

SD

SD

SD

SD

SDSD SD SD SD

WWWWWWW

W W

W

W W

W W

W W

W W

W

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SHEET ID

T.

S

M

IT

H

T.

F

R O

ST

C . C

AR

TE

R

J.

M

AC

M

IL

O F

D

EM

O

LI

TI

O

N P

LA

CD108

of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

. P L.

LO

U

IS

VI

LL

E, K Y

SE

PT

EM

BE

R

IS

SO

M A

IR

R

ES

ER

VE

B

AS

E

IN

D

O O

R S

M

AL

L

AR

M S

R

AN

G E

PN

C

TG

B1

2-

, P

, F

TI

FI

ED

F

IN

AL

1. CONTRACTOR TO COORDINATE DEMOLITION ACTIVITIES WITH

CONTRACTING OFFICER'S REPRESENTATIVE (COR) AND BASE PERSONNEL

IN ORDER TO ENSURE CONSTRUCTION ACTIVITIES DO NOT INTERFERE

WITH BASE ACTIVITIES.

2. CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES PRIOR TO ANY

CONSTRUCTION ACTIVITY.

3. EXISTING UTILITIES AND SITE STRUCTURES NOT IDENTIFIED FOR

DEMOLITION MUST BE PROTECTED DURING DEMOLITION AND

CONSTRUCTION.

4. DEMOLITION OF EXISTING SMALL ARMS RANGE FACILITY IS NOT TO OCCUR

UNTIL NEW RANGE FACILITY IS CONSTRUCTED AND TURNED OVER TO BASE

FOR OPERATIONS.

GENERAL SHEET NOTES

SHEET KEYNOTES

1. CONTRACTOR TO DEMOLISH EXISTING SMALL ARMS RANGE FENCE AND

GATE. IF GATE LOCK IS STILL PRESENT ON FENCE, CONTRACTOR TO

COORDINATE WITH COR TO RETURN LOCK TO PROPER BASE PERSONNEL.

2. CONTRACTOR TO DEMOLISH EXISTING UTILITIES ACCORDING TO

SPECIFICATION 02 41 00. COORDINATE WITH COR TO ENSURE BASE

PERSONNEL HAVE REMOVED ALL ITEMS FROM THE EXISTING FACILITY AND

HAVE FULLY OCCUPIED THE PROPOSED FACILITY. IF EXISTING UTILITIES ARE

EXCAVATED THEN THE CONTRACTOR MUST BACKFILL AND GRADE UTILITY

TRENCH TO EXISTING GROUND ELEVATIONS. THE CONTRACTOR MUST THEN

PERMANENTLY SEED DISTURBED GROUND. EXISTING UTILITIES ARE SHOWN

IN THE PLANS AND ADDITIONAL UTILITIES ARE SHOWN IN THE EXISTING

SMALL ARMS FACILITY SITE DETAILS ON SHEETS CD501 AND CD502. EXISTING

UTILITIES ARE TO BE DEMOLISHED ACCORDING TO PLAN SHEETS OR 10 FEET

FROM THE EXISTING FACILITY IF THE DEMOLITION EXTENT IS NOT SHOWN.

ALL UTILITIES DEMOLISHED MUST BE WATERTIGHT SEALED AND CAPPED. THE

CONTRACTOR MUST NOTIFY ALL UTILITY OWNER/OPERATORS MORE THAN 14

DAYS PRIOR TO DEMOLITION TO ENSURE SERVICES ARE NOT ACTIVE AT THE

TIME OF DEMOLITION.

3. DEMOLISH EXISTING SMALL ARMS RANGE FACILITY AND ADJACENT

SUPPORTING STRUCTURES. DEMOLITION INCLUDES THE EXISTING FACILITY

VERTICAL STRUCTURE, BUILDING PAD, AND FOUNDATION STRUCTURES.

CONTRACTOR TO USE TOPSOIL FROM PROPOSED RANGE SITE TO FILL THE

EXCAVATED FOUNDATION AREA. GRADE TO DRAIN TO EXISTING DRAINAGE

SYSTEMS. THE CONTRACTOR MUST THEN PERMANENTLY SEED DISTURBED

GROUND. SEE SHEETS REFERENCE PROJECT SHEETS FOR INFORMATION ON

EXISTING SMALL ARMS RANGE.

4. DEMOLISH EXISTING GRAVEL TRAIL AT INDICATED LOCATION. REMOVE

AGGREGATE AS NECESSARY TO GRADE FOR PROPOSED FACILITY AND

SUPPORTING STRUCTURES.

5. REMOVE EXISTING TREES TO BE REPLACED WITH LIKE KIND BASED ON

SPECIFICATION 32 93 00. SEE CIVIL SITE (CS) SERIES SHEETS FOR LOCATIONS

OF NEW TREES.

6. EXISTING RANGE ROAD TO REMAIN. CONTRACTOR TO TAKE NOTE OF

EXISTING CONDITION AND MAINTAIN DURING DEMOLITION.

7. EXISTING CURB AND GUTTER TO BE REMOVED TO TIE IN PROPOSED DRIVE TO

EXISTING PARKING AREA FOR EDGE KEY.

8. EXISTING FOOT GOLF HOLE TO BE RELOCATED. SEE LOCATION ON SHEET

CS105.

9. EXISTING FOOTGOLF HOLE TO BE TEMPORARILY REMOVED DURING

CONSTRUCTION. ONCE CONSTRUCTION IS COMPLETE, FOOTGOLF HOLE IS TO

BE REPLACED IN LOCATION ACCORDING TO SITE PLANS.

10. CURB AND GUTTER REMOVAL FOR PROPOSED CONSTRUCTION ENTRANCE TO

BE REPLACED TO EXISTING GRADE BY CONTRACTOR ONCE PROJECT IS

STABILIZED AND CONSTRUCTION ENTRANCE IS NO LONGER NEEDED.

11. EXPLOSIVE SAFETY QUANTITY DISTANCE (ESQD) FROM THE EXISTING

MUNITIONS STORAGE FACILITY TO THE WEST OF THE PROJECT. IF WORKING

WITHIN THE ESQD, CONTRACTOR MUST NOTIFY COR TO COORDINATE

CONSTRUCTION ACTIVITIES.

12. CONTRACTOR TO PROTECT TREES TO REMAIN ACCORDING TO DETAIL J13

SHEET GC501.

13. REMOVE EXISTING CATCH BASIN STRUCTURE.

14. REMOVE EXISTING 10 INCH CORRUGATED PE PIPE.

15. REMOVE AND REPLACE EXISTING SIGNS.

16. REMOVE AND REPLACE ASPHALT AND CURB DURING UTILITY CONSTRUCTION.

REPLACEMENT ASPHALT AND CURB MUST MATCH EXISTING PAVEMENT

SECTION, CURB TYPE, ELEVATIONS, AND GRADES. NO CURB ON EXISTING

SMALL ARMS RANGE ENTRANCE, CONTRACTOR TO REPLACE WITH MATCHING

PAVEMENT SECTION AND ELEVATIONS TO EXISTING DRIVE.

LEGEND

PROPOSED STRUCTURE AND PAVEMENT REMOVAL

PROPOSED LINEAR REMOVAL

PROPOSED TREE OR SHRUB REMOVAL

PROPOSED CONTRACTOR WORK LIMITS

_1

_1

_2

_2

A1 SCALE: 1"=20'

DEMOLITION PLAN

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

FE

B

_1

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

F

EB

W

2Q R

B0

1_

Pl an s-

ESQD

ESQD

ESQD

ESQD

F F

F

W

W W W

F F

F F

WW

W W

W W

W W

W W

WW

W

W

W

W W

W W

W W

W W

WWW

W W

F F

F

W W

W W

W

W

W W

W W

W W

W W

W

W

W

W

W W W W W W W W W W W W

W

W

SD

SD

SD

SD

SAN SAN

SAN SAN

SA

N

SA

N

SAN

SAN

SAN

SAN

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SAN

SAN

SAN

G G

G G

G

G G

G G

G

G G

G

G

G

G

G G

G G

G G

G

G

G

EE

E

E

E E

E E

E E

E E

E

E

E

E E

E E

E E

E E

E

E E

E

P

E E

E E

E E

E E

E E

E E

E E

E E

E

SD

SD

SD

SD

SD

SD

W W

SD

SD

SA

N

W

W W

W W

W W

W W

W

SD SD SD

W W

W W W W W

W W W

W W W

W

WWWWW

ACCESS

ACCESS

ACCESS

ACCESS

ACCESS

ESQD

EEEE

F F

F

W

W W W

F F

F F

WW

W W

W W

W W

W W

WW

W

W

W

W W

W W

W W

W W

WWW

W W

F F

F

W W

W W

W

W

W W

W W

W W

W W

W

W

W

W

W W W W W W W W W W W W

W

W

SD

SD

SD

SD

SAN SAN

SAN SAN

SA

N

SA

N

SAN

SAN

SAN

SAN

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SAN

SAN

SAN

G G

G G

G

G G

G G

G

G G

G

G

G

G

G G

G G

G G

G

G

G

EE

E

E

E E

E E

E E

E E

E

E

E

E E

E E

E E

E E

E

E E

E

P

E E

E E

E E

E E

E E

E E

E E

E E

E

SD

SD

SD

SD

SD

SD

W W

SD

SD

SA

N

W

W W

W W

W W

W W

W

SD SD SD

W W

W W W W W

W W W

W W W

W

CS102

CS104

CS106

CS107

CS103

CS105

CS108

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SHEET ID

T.

S

M

IT

H

T.

F

R O

ST

C . C

AR

TE

R

J.

M

AC

M

IL

LA

N O

VE

R

AL

L

C

IV

IL

S

IT

E

PL

AN

CS101

ISAR

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

. P L.

LO

U

IS

VI

LL

E, K Y

SE

PT

EM

BE

R

AN

SI

D

G R

IS

SO

M A

IR

R

ES

ER

VE

B

AS

E

IN

D

O O

R S

M

AL

L

AR

M S

R

AN

G E

PN

C

TG

B1

2-

, P

, F Y

C

ER

TI

FI

ED

F

IN

AL

GENERAL SHEET NOTES

1. ALL DIMENSIONS ARE PROVIDED IN U.S. SURVEY FEET, UNLESS INDICATED

OTHERWISE.

2. DIMENSIONS ARE TO THE EDGE OF PAVEMENT.

3. CONTRACTOR TO COORDINATE CONSTRUCTION ACTIVITIES WITH THE

CONTRACTING OFFICER'S REPRESENTATIVE (COR) AND BASE PERSONNEL IN

ORDER TO ENSURE CONSTRUCTION ACTIVITIES DO NOT INTERFERE WITH

BASE ACTIVITIES OR CONSTRUCTION ACTIVITIES ON BASE.

4. FOR GRADING AND DRAINAGE, SEE GRADING SHEETS CG101-CG104.

5. ANY WORK PERFORMED WITHIN THE EXPLOSION SAFETY QUANTITY

DISTANCE SHALL BE COORDINATED WITH THE COR AND BASE PERSONNEL

PRIOR TO WORK BEING PERFORMED.

LEGEND

CB

SD

PROPOSED ASPHALT PAVEMENT (DETAIL G9, SHEET CS501)

PROPOSED CONCRETE PAVED SIDEWALKS AND DUMPSTER PAD

AS NOTED

PROPOSED AGGREGATE PAVEMENT (AS NOTED)

PROPOSED STORMWATER MANAGEMENT BASIN

(DETAIL A1 SHEET CG503 AND CG504)

PROPOSED CATCH BASIN (DETAIL A11, SHEET CG501)

PROPOSED STORM SEWER PIPE

PROPOSED BOLLARD (DETAIL H5, SHEET CS502)

PROPOSED CONIFEROUS TREE, SEE SPECIFICATION

32 93 00 SECTION

A1 SCALE: 1"=100'

OVERALL CIVIL SITE PLAN

PLAN

NORTH

100' 200'0

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

F

EB

_1

W

2Q R

B0

1_

Pl an s-

MATCHLINE - SEE SHEET CS103

- SEE SHEET CS105

SD

PI

: 2

+3 9.

PI

: 2

+8 7.

PC

: 4

+4 1.

PT: 4+98.21

5+00

N: 1971586.25 E: 191448.64

N: 1971620.92 E: 191490.03

N: 1971625.92 E: 191483.08

N: 1971625.92 E: 191431.61

N: 1971595.92 E: 191401.61

N: 1971551.46 E: 191646.40

N: 1971637.92 E: 191369.61

N: 1971669.92 E: 191490.03

R5' R5'

N: 1971637.92 E: 191478.03

ACCESS

ACCESS

PROPOSED INDOOR

SMALL ARMS RANGE

N: 1971617.92 E: 191369.61

N: 1971595.92 E: 191389.61

5.

5'

5.

5'

5'

5'

5'

2.

5'

N: 1971637.92 E: 191389.61

N: 1971561.19 E: 191401.61

N: 1971669.92 E: 191634.03

N: 1971573.04 E: 191631.40

21'

6'

R5'

14'

11'

R10'

9'

N: 1971617.92 E: 191389.61

N: 1971573.16 E: 191444.62

4.99' (TYP.)

6'

5'

13.71' (TYP.)6'

(T

YP

.)4' (TYP.)

3' (T

YP

N: 1971561.19 E: 191444.62

N: 1971580.25 E: 191473.76

N: 1971580.25 E: 191453.70

10.13'

N: 1971573.16 E: 191585.64

N: 1971573.16 E: 191571.90

N: 1971597.92 E: 191490.03

N: 1971631.92 E: 191431.61

N: 1971595.92 E: 191395.61

6'

6' 6'

5.

5'

4.

6'

2.

5'

20'

9.87'

N: 1971601.26 E: 191483.63

15.00'

AG

G

R

EG

ATE TR

AIL

ESQD

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SHEET ID

T.

S

M

IT

H

T.

F

R O

ST

C . C

AR

TE

R

J.

M

AC

M

IL

LA

N C

IV

IL

S

IT

E

PL

AN

CS103

ISAR

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

. P L.

LO

U

IS

VI

LL

E, K Y

SE

PT

EM

BE

R

AN

SI

D

G R

IS

SO

M A

IR

R

ES

ER

VE

B

AS

E

IN

D

O O

R S

M

AL

L

AR

M S

R

AN

G E

PN

C

TG

B1

2-

, P

, F Y

C

ER

TI

FI

ED

F

IN

AL

1. ALL DIMENSIONS ARE PROVIDED IN U.S. SURVEY FEET, UNLESS INDICATED

OTHERWISE.

2. DIMENSIONS ARE TO THE EDGE OF PAVEMENT.

3. CONTRACTOR TO COORDINATE CONSTRUCTION ACTIVITIES WITH THE

CONTRACTING OFFICER'S REPRESENTATIVE (COR) AND BASE PERSONNEL IN

ORDER TO ENSURE CONSTRUCTION ACTIVITIES DO NOT INTERFERE WITH

BASE ACTIVITIES OR OTHER CONSTRUCTION ACTIVITIES.

4. FOR GRADING AND DRAINAGE, SEE GRADING SHEETS CG101-CG104.

5. ANY WORK PERFORMED WITHIN THE EXPLOSION SAFETY QUANTITY

DISTANCE SHALL BE COORDINATED WITH THE COR AND BASE PERSONNEL

PRIOR TO WORK BEING PERFORMED.

GENERAL SHEET NOTES

SHEET KEYNOTES

PROPOSED ASPHALT PAVEMENT (DETAIL G9, SHEET CS501)

PROPOSED CONCRETE PAVED SIDEWALKS, MECHANICAL PADS /

YARD, AND DUMPSTER PAD (AS NOTED)

PROPOSED AGGREGATE PAVEMENT (AS NOTED)

PROPOSED STORMWATER MANAGEMENT BASIN

(DETAIL A1 SHEET CG503 AND CG504)

CB PROPOSED CATCH BASIN (DETAIL A11, SHEET CG501)

SD PROPOSED STORM SEWER PIPE

PROPOSED CONIFEROUS TREE, SEE SPECIFICATION

32 93 00 SECTION

KEY MAP

PROPOSED BOLLARD (DETAIL H5, SHEET CS502)

1. INSTALL NO SMOKING WITHIN 50' OF FACILITY SIGN. SEE DETAIL A9 ON SHEET

CS502.

2. INSTALL CONCRETE SIDEWALK, SEE DETAIL A1 SHEET CS501.

3. 33' ATFP SETBACK.

4. COVERED SIDEWALK AREA FOR ENTRY TO THE INDOOR SMALL ARMS RANGE.

5. TIE PROPOSED INDOOR SMALL ARMS RANGE ENTRANCE INTO EXISTING

PARKING AREA WITH EDGE KEY. SEE DETAIL L5 SHEET CS501.

6. PROVIDE REGRADE OF EXISTING GRAVEL TRAIL. AGGREGATE SECTION

PROVIDED ON SHEET CS501, DETAIL L8.

7. INSTALL CONCRETE DUMPSTER PAD FOR GARBAGE PICKUP. SEE DETAIL A11

SHEET CS501.

8. EXISTING AGGREGATE TRAIL TO BE PAVED WITH ASPHALT. GRADES TO

MATCH EXISTING TRAIL GRADES WHERE ELEVATIONS NOT PROVIDED.

PAVEMENT SECTION ACCORDING TO DETAIL A16, CS502.

9. PROVIDE ASPHALT PAVEMENT SECTION FOR ACCESS TO FACILITY PROVIDED

ON SHEET CS501, DETAIL G9.

10. INSTALL MECHANICAL EQUIPMENT YARD. SEE DETAIL D11 SHEET CS501.

11. INSTALL CONCRETE CURB TAPER. SEE DETAIL G5, SHEET CS501.

12. INSTALL SIDEWALK RAMP WITH TRUNCATED DOMES. SEE DETAIL A1 SHEET

CS503.

13. AGGREGATE PAVEMENT, SEE DETAIL G16, SHEET CS501. BID OPTION 001 IS

TO PAVE THIS AREA WITH ASPHALT. USE KEYNOTE 9 FOR BID OPTION 001.

14. RELOCATED FOOTGOLF HOLE.

15. CONTRACTOR TO PROVIDE SIGNAGE FOR PEDESTRIAN TRAIL ALTERNATE

ROUTE DURING CONSTRUCTION. CONTRACTOR TO USE DETOUR SIGNAGE

ACCORDING TO MUTCD M4-9B FOR PEDESTRIAN DETOURS. PLACEMENT OF

SIGNAGE IS ACCORDING TO PLANS. L FOR LEFT ARROW AND R FOR RIGHT

ARROW. PATH DIRECTION IS FROM NORTH TO SOUTH.

16. EXPLOSIVE SAFETY QUANTITY DISTANCE OUTER LIMIT FROM MUNITIONS

STORAGE FACILITY WEST OF SITE.

17. INSTALL CURB AND GUTTER TO BE INSTALLED PER DETAIL L15 SHEET CS501.

18. INSTALL FACILITY SIGN SEE DETAIL J11 SHEET CS502.

19. INSTALL MECHANICAL EQUIPMENT PAD/PATH, SEE DETAIL D11 SHEET CS501.

20. INSTALL PIPE BOLLARD. SEE DETAIL H5, SHEET CS502.

21. CONTRACTOR TO REPAIR ASPHALT PAVEMENT AND CURB FROM UTILITY CUT.

ASPHALT SECTION TO MATCH EXISTING AND CURB TO BE REPLACED WITH

LIKE KIND TO THE EXISTING ELEVATIONS.

22. BID OPTION 2. INSTALL CONCRETE MECHANICAL EQUIPMENT PAD FOR AUGER

SYSTEM STORAGE BARREL, SEE DETAIL D11 SHEET CS501.

LEGEND

_1

_2

A1 SCALE: 1"=20'

CIVIL SITE PLAN

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

FE

B

_1

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

F

EB

W

2Q R

B0

1_

Pl an s-

ACCESS

10'

L

L

MATCHLINE - SEE SHEET CS102

- SEE SHEET CS104

MATCHLINE - SEE SHEET CS104

- SEE SHEET CS106

W

W W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SAN

SAN

SAN

SAN

SA

G G

G G

G G

G G

G G

G G

G G

G G

G

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

SD

SD

SD

SD

SD

SD

SD SD SD SD SD SD SD SD

SD

SD

SD

SD

SD

SD

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SHEET ID

T.

S

M

IT

H

T.

F

R O

ST

C . C

AR

TE

R

J.

M

AC

M

IL

LA

N C

IV

IL

S

IT

E

PL

AN

CS104

ISAR

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

. P L.

LO

U

IS

VI

LL

E, K Y

SE

PT

EM

BE

R

AN

SI

D

G R

IS

SO

M A

IR

R

ES

ER

VE

B

AS

E

IN

D

O O

R S

M

AL

L

AR

M S

R

AN

G E

PN

C

TG

B1

2-

, P

, F Y

C

ER

TI

FI

ED

F

IN

AL

1. ALL DIMENSIONS ARE PROVIDED IN U.S. SURVEY FEET, UNLESS INDICATED

OTHERWISE.

2. DIMENSIONS ARE TO THE EDGE OF PAVEMENT.

3. CONTRACTOR TO COORDINATE CONSTRUCTION ACTIVITIES WITH THE

CONTRACTING OFFICER'S REPRESENTATIVE (COR) AND BASE PERSONNEL IN

ORDER TO ENSURE CONSTRUCTION ACTIVITIES DO NOT INTERFERE WITH

BASE ACTIVITIES OR OTHER CONSTRUCTION ACTIVITIES.

4. FOR GRADING AND DRAINAGE, SEE GRADING SHEETS CG101-CG104.

5. ANY WORK PERFORMED WITHIN THE EXPLOSION SAFETY QUANTITY

DISTANCE SHALL BE COORDINATED WITH THE COR AND BASE PERSONNEL

PRIOR TO WORK BEING PERFORMED.

GENERAL SHEET NOTES

SHEET KEYNOTES

PROPOSED ASPHALT PAVEMENT (DETAIL G9, SHEET CS501)

PROPOSED CONCRETE PAVED SIDEWALKS, MECHANICAL PADS /

YARD, AND DUMPSTER PAD (AS NOTED)

PROPOSED AGGREGATE PAVEMENT (AS NOTED)

PROPOSED STORMWATER MANAGEMENT BASIN

(DETAIL A1 SHEET CG503 AND CG504)

CB PROPOSED CATCH BASIN (DETAIL A11, SHEET CG501)

SD PROPOSED STORM SEWER PIPE

PROPOSED CONIFEROUS TREE, SEE SPECIFICATION

32 93 00 SECTION

KEY MAP

PROPOSED BOLLARD (DETAIL H5, SHEET CS502)

1. INSTALL NO SMOKING WITHIN 50' OF FACILITY SIGN. SEE DETAIL A9 ON SHEET

CS502.

2. INSTALL CONCRETE SIDEWALK, SEE DETAIL A1 SHEET CS501.

3. 33' ATFP SETBACK.

4. COVERED SIDEWALK AREA FOR ENTRY TO THE INDOOR SMALL ARMS RANGE.

5. TIE PROPOSED INDOOR SMALL ARMS RANGE ENTRANCE INTO EXISTING

PARKING AREA WITH EDGE KEY. SEE DETAIL L5 SHEET CS501.

6. PROVIDE REGRADE OF EXISTING GRAVEL TRAIL. AGGREGATE SECTION

PROVIDED ON SHEET CS501, DETAIL L8.

7. INSTALL CONCRETE DUMPSTER PAD FOR GARBAGE PICKUP. SEE DETAIL A11

SHEET CS501.

8. EXISTING AGGREGATE TRAIL TO BE PAVED WITH ASPHALT. GRADES TO

MATCH EXISTING TRAIL GRADES WHERE ELEVATIONS NOT PROVIDED.

PAVEMENT SECTION ACCORDING TO DETAIL A16, CS502.

9. PROVIDE ASPHALT PAVEMENT SECTION FOR ACCESS TO FACILITY PROVIDED

ON SHEET CS501, DETAIL G9.

10. INSTALL MECHANICAL EQUIPMENT YARD. SEE DETAIL D11 SHEET CS501.

11. INSTALL CONCRETE CURB TAPER. SEE DETAIL G5, SHEET CS501.

12. INSTALL SIDEWALK RAMP WITH TRUNCATED DOMES. SEE DETAIL A1 SHEET

CS503.

13. AGGREGATE PAVEMENT, SEE DETAIL G16, SHEET CS501. BID OPTION 001 IS

TO PAVE THIS AREA WITH ASPHALT. USE KEYNOTE 9 FOR BID OPTION 001.

14. RELOCATED FOOTGOLF HOLE.

15. CONTRACTOR TO PROVIDE SIGNAGE FOR PEDESTRIAN TRAIL ALTERNATE

ROUTE DURING CONSTRUCTION. CONTRACTOR TO USE DETOUR SIGNAGE

ACCORDING TO MUTCD M4-9B FOR PEDESTRIAN DETOURS. PLACEMENT OF

SIGNAGE IS ACCORDING TO PLANS. L FOR LEFT ARROW AND R FOR RIGHT

ARROW. PATH DIRECTION IS FROM NORTH TO SOUTH.

16. EXPLOSIVE SAFETY QUANTITY DISTANCE OUTER LIMIT FROM MUNITIONS

STORAGE FACILITY WEST OF SITE.

17. INSTALL CURB AND GUTTER TO BE INSTALLED PER DETAIL L15 SHEET CS501.

18. INSTALL FACILITY SIGN SEE DETAIL J11 SHEET CS502.

19. INSTALL MECHANICAL EQUIPMENT PAD/PATH, SEE DETAIL D11 SHEET CS501.

20. INSTALL PIPE BOLLARD. SEE DETAIL H5, SHEET CS502.

21. CONTRACTOR TO REPAIR ASPHALT PAVEMENT AND CURB FROM UTILITY CUT.

ASPHALT SECTION TO MATCH EXISTING AND CURB TO BE REPLACED WITH

LIKE KIND TO THE EXISTING ELEVATIONS.

22. BID OPTION 2. INSTALL CONCRETE MECHANICAL EQUIPMENT PAD FOR AUGER

SYSTEM STORAGE BARREL, SEE DETAIL D11 SHEET CS501.

LEGEND

_1

_2

A1 SCALE: 1"=20'

CIVIL SITE PLAN

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

FE

B

R

EV

IS

ED

IN

A

C C

O R

D

AN

C E

W

IT

H A

M

EN

D M

EN

T

F

EB

W

2Q R

B0

1_

Pl an s-

PC: 6+21.38

ACCESS

ACCESS

5'

12' 24.31' (TYP.) 18.70' (TYP.)

N: 1971430.75 E: 191695.95

N: 1971442.75 E: 191695.95

N: 1971430.75 E: 191585.95

N: 1971370.75 E: 191635.95

N: 1971430.75 E: 191665.95

13.71' (TYP.)

4' (TYP.)

62' 15.9'

N: 1971400.82 E: 191635.95

5.28'

(TYP.)

MATCHLINE - SEE SHEET CS103

- SEE SHEET CS105

ESQD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SHEET ID

O

PT

IO

N

AL

V

AL

U E

1%

O

PT

IO

N

AL

V

AL

U E

2%

T.

S

M

IT

H

T.

F

R O

ST

C . C

AR

TE

R

J.

M

AC

M

IL

LA

N C

IV

IL

S

IT

E

PL

AN

CS105

ISAR

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

. P L.

LO

U

IS

VI

LL

E, K Y

SE

PT

EM

BE

R

AN

SI

D

G R

IS

SO

M A

IR

R

ES

ER

VE

B

AS

E

IN

D

O O

R S

M

AL

L

AR

M S

R

AN

G E

PN

C

TG

B1

2-

, P

, F Y

C

ER

TI

FI

ED

F

IN

AL

1. ALL DIMENSIONS ARE PROVIDED IN U.S. SURVEY FEET, UNLESS INDICATED

OTHERWISE.

2. DIMENSIONS ARE TO THE EDGE OF PAVEMENT.

3. CONTRACTOR TO COORDINATE CONSTRUCTION ACTIVITIES WITH THE

CONTRACTING OFFICER'S REPRESENTATIVE (COR) AND BASE PERSONNEL IN

ORDER TO ENSURE CONSTRUCTION ACTIVITIES DO NOT INTERFERE WITH

BASE ACTIVITIES OR OTHER CONSTRUCTION ACTIVITIES.

4. FOR GRADING AND DRAINAGE, SEE GRADING SHEETS CG101-CG104.

5. ANY WORK PERFORMED WITHIN THE EXPLOSION SAFETY QUANTITY

DISTANCE SHALL BE COORDINATED WITH THE COR AND BASE PERSONNEL

PRIOR TO WORK BEING PERFORMED.

GENERAL SHEET NOTES

SHEET KEYNOTES

PROPOSED ASPHALT PAVEMENT (DETAIL G9, SHEET CS501)

PROPOSED CONCRETE PAVED SIDEWALKS, MECHANICAL PADS /

YARD, AND DUMPSTER PAD (AS NOTED)

PROPOSED AGGREGATE PAVEMENT (AS NOTED)

PROPOSED STORMWATER MANAGEMENT BASIN

(DETAIL A1 SHEET CG503 AND CG504)

CB PROPOSED CATCH BASIN (DETAIL A11, SHEET CG501)

SD PROPOSED STORM SEWER PIPE

PROPOSED CONIFEROUS TREE, SEE SPECIFICATION

32 93 00 SECTION

KEY MAP

PROPOSED BOLLARD (DETAIL H5, SHEET CS502)

1. INSTALL NO SMOKING WITHIN 50' OF FACILITY SIGN. SEE DETAIL A9 ON SHEET

CS502.

2. INSTALL CONCRETE SIDEWALK, SEE DETAIL A1 SHEET CS501.

3. 33' ATFP SETBACK.

4. COVERED SIDEWALK AREA FOR ENTRY TO THE INDOOR SMALL ARMS RANGE.

5. TIE PROPOSED INDOOR SMALL ARMS RANGE ENTRANCE INTO EXISTING

PARKING AREA WITH EDGE KEY. SEE DETAIL L5 SHEET CS501.

6. PROVIDE REGRADE OF EXISTING GRAVEL TRAIL. AGGREGATE SECTION

PROVIDED ON SHEET CS501, DETAIL L8.

7. INSTALL CONCRETE DUMPSTER PAD FOR GARBAGE PICKUP. SEE DETAIL A11

SHEET CS501.

8. EXISTING AGGREGATE TRAIL TO BE PAVED WITH ASPHALT. GRADES TO

MATCH EXISTING TRAIL GRADES WHERE ELEVATIONS NOT PROVIDED.

PAVEMENT SECTION ACCORDING TO DETAIL A16, CS502.

9. PROVIDE ASPHALT PAVEMENT SECTION FOR ACCESS TO FACILITY PROVIDED

ON SHEET CS501, DETAIL G9.

10. INSTALL MECHANICAL EQUIPMENT YARD. SEE DETAIL D11 SHEET CS501.

11. INSTALL CONCRETE CURB TAPER. SEE DETAIL G5, SHEET CS501.

12. INSTALL SIDEWALK RAMP WITH TRUNCATED DOMES. SEE DETAIL A1 SHEET

CS503.

13. AGGREGATE PAVEMENT, SEE DETAIL G16, SHEET CS501. BID OPTION 001 IS

TO PAVE THIS AREA WITH ASPHALT. USE KEYNOTE 9 FOR BID OPTION 001.

14. RELOCATED FOOTGOLF HOLE.

15. CONTRACTOR TO PROVIDE SIGNAGE FOR PEDESTRIAN TRAIL ALTERNATE

ROUTE DURING CONSTRUCTION. CONTRACTOR TO USE DETOUR SIGNAGE

ACCORDING TO MUTCD M4-9B FOR PEDESTRIAN DETOURS. PLACEMENT OF

SIGNAGE IS ACCORDING TO PLANS. L FOR LEFT ARROW AND R FOR RIGHT

ARROW. PATH DIRECTION IS FROM NORTH TO SOUTH.

16. EXPLOSIVE SAFETY QUANTITY DISTANCE OUTER LIMIT FROM MUNITIONS

STORAGE FACILITY WEST OF SITE.

17. INSTALL CURB AND GUTTER TO BE INSTALLED PER DETAIL L15 SHEET CS501.

18. INSTALL FACILITY SIGN SEE DETAIL J11 SHEET CS502.

19. INSTALL MECHANICAL EQUIPMENT PAD/PATH, SEE DETAIL D11 SHEET CS501.

20. INSTALL PIPE BOLLARD. SEE DETAIL H5, SHEET CS502.

21. CONTRACTOR TO REPAIR ASPHALT PAVEMENT AND CURB FROM UTILITY CUT.

ASPHALT SECTION TO MATCH EXISTING AND CURB TO BE REPLACED WITH

LIKE KIND TO THE EXISTING ELEVATIONS.

22. BID OPTION 2. INSTALL CONCRETE MECHANICAL EQUIPMENT PAD FOR AUGER

SYSTEM STORAGE BARREL, SEE DETAIL D11 SHEET CS501.

LEGEND

_1

_2

A1 SCALE: 1"=20'

CIVIL SITE PLAN

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

FE

B

R

EV

IS

ED

IN

A

C C

O R

D

AN

C E

W

IT

H A

M

EN

D M

EN

T

F

EB

W

2Q R

B0

1_

Pl an s-

CB

CB

CI

CO OP

CB

CB

CB

CI

CO OP

CB

794 79

4 79

794794794

794 794

0 796

79779

ESQD

ESQD

ESQD

ESQD

BBCBCBCCCCCCCBCB

CICICCI

94949494

77977793993333333333377779999999337777977999933377777779779999933333777777777777797997977977993993999999933333333333333333333333377777777777777799999999999999979797979797977977979779333333333333333333333333333333333333333

777777777777777

CCC

CCCCCCCCCCCCCCCCCCCCCCCCCCCC

PROPOSED INDOOR

SMALL ARMS RANGE

4949494949494797979777797977 494979979979777 49449499797999777 4449494949494949499949497997997999 49449449449477777777777777999997999777777777777777777777779797979799799797997979797979979979979799799 49494944944444949494944949494944949449494494494494

ACCESS

ACCESS

ACCESS

ACCESS

ACCESS

PROPOSED INDOOR

SMALL ARMS RANGE

79794797944794794797994479794

ESQD

F F

F

W

W W W

F F

F F

WW

W W

W W

W W

W W

WW

W

W

W W

W W

W W

W W

W

WWW

W W

F F

F

W W

W W

W

W

W W

W W

W W

W W

W

W

W

W W

W W W W W W W W W W W W

W

W

SD

SD

SD

SD

SAN SAN

SAN SAN

SA

N

SA

N

SAN

SAN

SAN

SAN

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SAN

SAN

SAN

G G

G G

G

G G

G G

G

G G

G

G

G

G

G G

G G

G G

G

G

G

EE

E

E

E E

E E

E E

E E

E

E

E

E E

E E

E E

E E

E

E E

E

P

E E

E E

E E

E E

E E

E E

E E

E E

E

SD

SD

SD

SD

SD

SD

W W

U

PE

U

PE

UPE

UPE

UP

E

UPEUPEUPE

UT

E

UTE

UTE

UTE

U

TE

UTE

UTE

U

TE

UTE

UTE

U D

U D

U D

U D

U D

U D

U D

U D

UD

UD

UDUD

SD

SD

SA

N

W

W W

W W

W W

W W

W

SD SD SD

W W

W W W W W

W W W

W W W

W

BUILDING 596 PARKING

(ASPHALT)

BUILDING 596

BUILDING 641 PARKING

BOXCAR STREET

(ASPHALT)

EXISTING INDOOR SMALL

ARMS RANGE

BUILDING 629

GRISSOM AVENUE

(ASPHALT)

PARKING

(ASPHALT)

F F

F

W

W W W

F F

F F

WW

W W

W W

W W

W W

WW

W

W

W W

W W

W W

W W

W

WWW

W W

F F

F

W W

W W

W

W

W W

W W

W W

W W

W

W

W

W W

W W W W W W W W W W W W

W

W

SD

SD

SD

SD

SAN SAN

SAN SAN

SA

N

SA

N

SAN

SAN

SAN

SAN

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SAN

SAN

SAN

G G

G G

G

G G

G G

G

G G

G

G

G

G

G G

G G

G G

G

G

G

EE

E

E

E E

E E

E E

E E

E

E

E

E E

E E

E E

E E

E

E E

E

P

E E

E E

E E

E E

E E

E E

E E

E E

E

SD

SD

SD

SD

SD

SD

W W

U

PE

U

PE

UPE

UPE

UP

E

UPEUPEUPE

UT

E

UTE

UTE

UTE

U

TE

UTE

UTE

U

TE

UTE

UTE

U D

U D

U D

U D

U D

U D

U D

U D

UD

UD

UDUD

SD

SD

SA

N

W

W W

W W

W W

W W

W

SD SD SD

W W

W W W W W

W W W

W W W

W

CG103

CG104

CG102

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SHEET ID

T.

S

M

IT

H

T.

F

R O

ST

C . C

AR

TE

R

J.

M

AC

M

IL

LA

N (1

O F

4) O

VE

R

AL

L

G R

AD

IN

G P

LA

N

CG101

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

. P L.

LO

U

IS

VI

LL

E, K Y

SE

PT

EM

BE

R

AN

SI

D

G R

IS

SO

M A

IR

R

ES

ER

VE

B

AS

E

IN

D

O O

R S

M

AL

L

AR

M S

R

AN

G E

PN

C

TG

B1

2-

, P

, F Y

C

ER

TI

FI

ED

F

IN

AL

GENERAL SHEET NOTES

1. ALL DIMENSIONS ARE PROVIDED IN U.S. SURVEY FEET, UNLESS INDICATED

OTHERWISE.

2. DIMENSIONS ARE TO THE EDGE OF PAVEMENT.

3. CONTRACTOR TO COORDINATE CONSTRUCTION ACTIVITIES WITH

CONTRACTING OFFICER REPRESENTATIVE (COR) AND BASE PERSONNEL IN

ORDER TO ENSURE CONSTRUCTION ACTIVITIES DO NOT INTERFERE WITH

BASE ACTIVITIES OR OTHER CONSTRUCTION ACTIVITIES ON BASE.

4. SEE DEMOLITION PLANS (CD101-CD111) FOR COORDINATES ON CONTRACTOR

WORK LIMITS (CWL).

5. UNLESS OTHERWISE NOTED, ALL DISTURBED AREAS ARE TO BE SEEDED PER

SPECIFICATION 32 92 19.

6. CONTOUR INTERVAL IS 1 FT.

7. SEE SHEET CG201 FOR STORM LINE PROFILES.

LEGEND

PROPOSED STORMWATER MANAGEMENT BASIN

SEE DETAILS A1 SHEET CG503 AND A1 SHEET CG504

CB PROPOSED CATCH BASIN SEE DETAIL A11 SHEET CG501

PROPOSED STORM SEWER PIPE

PROPOSED 12" PRECAST CONCRETE END SECTION

(ACCORDING TO DETAIL H1, CG501)

PROPOSED CURB INLET TYPE D, SEE DETAIL H1, SHEET CG502CI

PROPOSED PAVEMENT SUBDRAIN, SEE DETAIL A1, SHEET CG501

PROPOSED INFILTRATION MATERIAL, SEE DETAILS A1, SHEET

CG503 AND A1 SHEET CG504

OP PROPOSED OBSERVATION PORT, SEE DETAIL A1, SHEET CG504

PROPOSED CONIFEROUS TREE, SEE SPECIFICATION

32 93 00 SECTION

A1 SCALE: 1"=100'

OVERALL GRADING PLAN

PLAN

NORTH

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

F

EB

_1

W

2Q R

B0

1_

Pl an s-

PT: 4+98.21

ACCESS

MATCHLINE - SEE SHEET CG102

- SEE SHEET CG104

ESQD

SDSD

PROPOSED INDOOR SMALL ARMS RANGE

FINISHED FLOOR ELEVATION - 796.60

EAST BASIN

162' X 40'

NORTH BASIN

100' X 51'

WEST BASIN

30' X 117'

STORM LINE 1

SD

SD

SD

CB

CI

STORM LINE 4

HW1-1

CB1-2

CI1-3

HW1-4

HW1-6

CB4-1 HW4-2

N: 1971697.67 E: 191709.64

N: 1971697.79 E: 191686.41

N: 1971706.42 E: 191717.75

N: 1971590.77 E: 191363.77

N: 1971676.85 E: 191363.77

N: 1971686.85 E: 191373.77

N: 1971570.86 E: 191354.61

N: 1971580.38 E: 191658.03

N: 1971580.42 E: 191630.59

CB

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SHEET ID

T.

S

M

IT

H

T.

F

R O

ST

C . C

AR

TE

R

J.

M

AC

M

IL

LA

N (2

O F

4) G

R

AD

IN

G

P

LA

N

CG102

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

. P L.

LO

U

IS

VI

LL

E, K Y

SE

PT

EM

BE

R

AN

SI

D

G R

IS

SO

M A

IR

R

ES

ER

VE

B

AS

E

IN

D

O O

R S

M

AL

L

AR

M S

R

AN

G E

PN

C

TG

B1

2-

, P

, F Y

C

ER

TI

FI

ED

F

IN

AL

1. ALL DIMENSIONS ARE PROVIDED IN U.S. SURVEY FEET, UNLESS INDICATED

OTHERWISE.

2. DIMENSIONS ARE TO THE EDGE OF PAVEMENT.

3. CONTRACTOR TO COORDINATE CONSTRUCTION ACTIVITIES WITH

CONTRACTING OFFICER REPRESENTATIVE (COR) AND BASE PERSONNEL IN

ORDER TO ENSURE CONSTRUCTION ACTIVITIES DO NOT INTERFERE WITH

BASE ACTIVITIES OR OTHER CONSTRUCTION ACTIVITIES ON BASE.

4. SEE DEMOLITION PLANS (CD101-CD111) FOR COORDINATES ON CONTRACTOR

WORK LIMITS (CWL).

5. UNLESS OTHERWISE NOTED, ALL DISTURBED AREAS ARE TO BE SEEDED PER

SPECIFICATION 32 92 19.

6. CONTOUR INTERVAL IS 1 FT.

7. SEE SHEET CG201 FOR STORM LINE PROFILES.

GENERAL SHEET NOTES

SHEET KEYNOTES

1. INSTALL STORMWATER MANAGEMENT BASINS TO INCLUDE IMPORTED SOILS

REPLACING EXISTING SOILS FOR INFILTRATION WATER QUALITY TREATMENT.

SEE BASIN DETAILS A1 ON SHEETS CG503 AND CG504. SEE SPECIFICATION 33

40 00 FOR IMPORTED SOILS.

2. INSTALL DRAINAGE DITCH TO CONVEY SURFACE RUNOFF TO BASINS.

3. PROVIDE PERFORATED UNDERDRAIN SYSTEM FOR SOUTH BASIN. SEE DETAIL

A1, SHEET CG504.

4. PROVIDE 12" REINFORCED CONCRETE CULVERT.

5. TIE PROPOSED INDOOR SMALL ARMS RANGE ENTRANCE INTO EXISTING

PARKING AREA. MATCH GRADE INITIALLY WITH PARKING LOT TO TRANSITION

TO CROWN 1.5% SLOPE AND ROLL CURB TO SOUTH SIDE OF ASPHALT

PAVEMENT.

6. GRAVEL TRAIL TO BE REPLACED AND GRADE TO TIE INTO EDGE OF

PAVEMENT TO NORTH OF ASPHALT PAVEMENT.

7. INSTALL AGGREGATE LAYDOWN AREA FOR CONTRACTOR TO REMAIN IN

PLACE. INSTALL ACCORDING TO CS501.

8. INSTALL ASPHALT PAVEMENT SECTION FOR ACCESS TO FACILITY PROVIDED

ON SHEET CS501.

9. INSTALL AGGREGATE PAVEMENT. SEE SECTION ON SHEET CS501.

10. INSTALL NORTH BASIN EMERGENCY OVERFLOW WEIR TO BE PLACED OFFSET

FROM OUTLET PIPE AND HEADWALLS TO PREVENT EROSION. WEIR LENGTH IS

10 FEET AND TO BE PROTECTED BY EROSION CONTROL BLANKETS LACED

WITH SEED THAT MATCHES PERMANENT SEEDING. SEE DETAIL A1 SHEET

CG503.

11. INSTALL SOUTH BASIN EMERGENCY OVERFLOW WEIR. WEIR LENGTH IS 10

FEET. WEIR TO BE PROTECTED BY EROSION CONTROL BLANKETS LACED

WITH SEED THAT MATCHES PERMANENT SEEDING. SEE DETAIL A1 SHEET

CG504.

12. DOWNSPOUT TO SPLASH BLOCK ACCORDING TO DETAIL A11, SHEET CG502.

13. PAVEMENT EXPOSED DRAINAGE LAYER TO BE INSTALLED. SEE DETAIL A1,

SHEET CG505.

14. PAVEMENT EXPOSED DRAINAGE LAYER TO BE INSTALLED IF BID OPTION 001

IS AWARDED. SEE DETAIL A1, SHEET CG505.

15. INSTALL STORM LINE 3, THREE 6 INCH PVC STORM SEWER PIPE PLACED NEXT

TO EACH OTHER WITH 1' GAP ON CENTER. SEE PROFILE SHEET CG201. SEE

INLET AND OUTLET PROTECTION DETAIL H11, SHEET CG501 FOR SLOPE

PROTECTION. END SECTIONS ARE TO BE MITERED TO CONFORM WITH THE

PROPOSED SLOPE GRADE. AGGREGATE INLET AND OUTLET PROTECTIONS

ARE TO BE SLOPED TO THE PROPOSED GRADE.

16. EXISTING RANGE TO BE DEMOLISHED. EXCAVATED FOUNDATION AREAS ARE

TO BE FILLED IN WITH TOPSOILS FROM THE PROPOSED RANGE SITE AND

GRADED TO DRAIN TO EXISTING STORMWATER SYSTEMS. CONTRACTOR TO

PERMANENTLY SEED ONCE FINAL GRADE IS PROVIDED.

LEGEND

PROPOSED STORMWATER MANAGEMENT BASIN

SEE DETAILS A1 SHEET CG503 AND A1 SHEET CG504

CB PROPOSED CATCH BASIN SEE DETAIL A11 SHEET CG501

PROPOSED STORM SEWER PIPE

PROPOSED 12" PRECAST CONCRETE END SECTION

(ACCORDING TO DETAIL H1, CG501)

PROPOSED CURB INLET TYPE D, SEE DETAIL H1, SHEET CG502CI

PROPOSED INFILTRATION MATERIAL, SEE DETAILS A1, SHEET

CG503 AND A1 SHEET CG504

OP PROPOSED OBSERVATION PORT, SEE DETAIL A1, SHEET CG504

PROPOSED CONIFEROUS TREE, SEE SPECIFICATION

32 93 00 SECTION

A1 SCALE: 1"=20'

GRADING PLAN

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

FE

B

_1

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

F

EB

_2

W

2Q R

B0

1_

Pl an s-

W

W W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SAN

SAN

SAN

SAN

SAN

G G

G G

G G

G G

G G

G G

G G

G G

G

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

SD

SD

SD

SD

SD

SD

SD SD SD SD SD SD SD SD

SD

SD

SD

SD

SD

SD

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

W W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SAN

SAN

SAN

SAN

SAN

G G

G G

G G

G G

G G

G G

G G

G G

G

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

SD

SD

SD

SD

SD

SD

SD SD SD SD SD SD SD SD

SD

SD

SD

SD

SD

SD

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

EAST BASIN

162' X 40'

STORM

LINE 2

SD

HW2-1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SHEET ID

T.

S

M

IT

H

T.

F

R O

ST

C . C

AR

TE

R

J.

M

AC

M

IL

LA

N (3

O F

4) G

R

AD

IN

G

P

LA

N

CG103

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

. P L.

LO

U

IS

VI

LL

E, K Y

SE

PT

EM

BE

R

AN

SI

D

G R

IS

SO

M A

IR

R

ES

ER

VE

B

AS

E

IN

D

O O

R S

M

AL

L

AR

M S

R

AN

G E

PN

C

TG

B1

2-

, P

, F Y

C

ER

TI

FI

ED

F

IN

AL

1. ALL DIMENSIONS ARE PROVIDED IN U.S. SURVEY FEET, UNLESS INDICATED

OTHERWISE.

2. DIMENSIONS ARE TO THE EDGE OF PAVEMENT.

3. CONTRACTOR TO COORDINATE CONSTRUCTION ACTIVITIES WITH

CONTRACTING OFFICER REPRESENTATIVE (COR) AND BASE PERSONNEL IN

ORDER TO ENSURE CONSTRUCTION ACTIVITIES DO NOT INTERFERE WITH

BASE ACTIVITIES OR OTHER CONSTRUCTION ACTIVITIES ON BASE.

4. SEE DEMOLITION PLANS (CD101-CD111) FOR COORDINATES ON CONTRACTOR

WORK LIMITS (CWL).

5. UNLESS OTHERWISE NOTED, ALL DISTURBED AREAS ARE TO BE SEEDED PER

SPECIFICATION 32 92 19.

6. CONTOUR INTERVAL IS 1 FT.

7. SEE SHEET CG201 FOR STORM LINE PROFILES.

GENERAL SHEET NOTES

SHEET KEYNOTES

1. INSTALL STORMWATER MANAGEMENT BASINS TO INCLUDE IMPORTED SOILS

REPLACING EXISTING SOILS FOR INFILTRATION WATER QUALITY TREATMENT.

SEE BASIN DETAILS A1 ON SHEETS CG503 AND CG504. SEE SPECIFICATION 33

40 00 FOR IMPORTED SOILS.

2. INSTALL DRAINAGE DITCH TO CONVEY SURFACE RUNOFF TO BASINS.

3. PROVIDE PERFORATED UNDERDRAIN SYSTEM FOR SOUTH BASIN. SEE DETAIL

A1, SHEET CG504.

4. PROVIDE 12" REINFORCED CONCRETE CULVERT.

5. TIE PROPOSED INDOOR SMALL ARMS RANGE ENTRANCE INTO EXISTING

PARKING AREA. MATCH GRADE INITIALLY WITH PARKING LOT TO TRANSITION

TO CROWN 1.5% SLOPE AND ROLL CURB TO SOUTH SIDE OF ASPHALT

PAVEMENT.

6. GRAVEL TRAIL TO BE REPLACED AND GRADE TO TIE INTO EDGE OF

PAVEMENT TO NORTH OF ASPHALT PAVEMENT.

7. INSTALL AGGREGATE LAYDOWN AREA FOR CONTRACTOR TO REMAIN IN

PLACE. INSTALL ACCORDING TO CS501.

8. INSTALL ASPHALT PAVEMENT SECTION FOR ACCESS TO FACILITY PROVIDED

ON SHEET CS501.

9. INSTALL AGGREGATE PAVEMENT. SEE SECTION ON SHEET CS501.

10. INSTALL NORTH BASIN EMERGENCY OVERFLOW WEIR TO BE PLACED OFFSET

FROM OUTLET PIPE AND HEADWALLS TO PREVENT EROSION. WEIR LENGTH IS

10 FEET AND TO BE PROTECTED BY EROSION CONTROL BLANKETS LACED

WITH SEED THAT MATCHES PERMANENT SEEDING. SEE DETAIL A1 SHEET

CG503.

11. INSTALL SOUTH BASIN EMERGENCY OVERFLOW WEIR. WEIR LENGTH IS 10

FEET. WEIR TO BE PROTECTED BY EROSION CONTROL BLANKETS LACED

WITH SEED THAT MATCHES PERMANENT SEEDING. SEE DETAIL A1 SHEET

CG504.

12. DOWNSPOUT TO SPLASH BLOCK ACCORDING TO DETAIL A11, SHEET CG502.

13. PAVEMENT EXPOSED DRAINAGE LAYER TO BE INSTALLED. SEE DETAIL A1,

SHEET CG505.

14. PAVEMENT EXPOSED DRAINAGE LAYER TO BE INSTALLED IF BID OPTION 001

IS AWARDED. SEE DETAIL A1, SHEET CG505.

15. INSTALL STORM LINE 3, THREE 6 INCH PVC STORM SEWER PIPE PLACED NEXT

TO EACH OTHER WITH 1' GAP ON CENTER. SEE PROFILE SHEET CG201. SEE

INLET AND OUTLET PROTECTION DETAIL H11, SHEET CG501 FOR SLOPE

PROTECTION. END SECTIONS ARE TO BE MITERED TO CONFORM WITH THE

PROPOSED SLOPE GRADE. AGGREGATE INLET AND OUTLET PROTECTIONS

ARE TO BE SLOPED TO THE PROPOSED GRADE.

16. EXISTING RANGE TO BE DEMOLISHED. EXCAVATED FOUNDATION AREAS ARE

TO BE FILLED IN WITH TOPSOILS FROM THE PROPOSED RANGE SITE AND

GRADED TO DRAIN TO EXISTING STORMWATER SYSTEMS. CONTRACTOR TO

PERMANENTLY SEED ONCE FINAL GRADE IS PROVIDED.

LEGEND

PROPOSED STORMWATER MANAGEMENT BASIN

SEE DETAILS A1 SHEET CG503 AND A1 SHEET CG504

CB PROPOSED CATCH BASIN SEE DETAIL A11 SHEET CG501

PROPOSED STORM SEWER PIPE

PROPOSED 12" PRECAST CONCRETE END SECTION

(ACCORDING TO DETAIL H1, CG501)

PROPOSED CURB INLET TYPE D, SEE DETAIL H1, SHEET CG502CI

PROPOSED INFILTRATION MATERIAL, SEE DETAILS A1, SHEET

CG503 AND A1 SHEET CG504

OP PROPOSED OBSERVATION PORT, SEE DETAIL A1, SHEET CG504

PROPOSED CONIFEROUS TREE, SEE SPECIFICATION

32 93…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .