W912QR24R0046_Plans-0000.pdf
PDF 12 MB Posted
- Solicitation number
- W912QR24R0046
About this file
This document is a Solicitation (Solicitation Number: W912QR24R0046) for the ARCENT Readiness Training Center Microgrid Project at Camp Buehring, Kuwait. The intent is to select a single contractor to provide construction services for a microgrid installation at Camp Buehring. The Government will evaluate proposals based on the criteria described in the solicitation and award a firm fixed-price contract to the responsible offeror whose proposal represents the overall best value. The solicitation is being issued by the Department of the Army Corps of Engineers Engineering District Louisville. The Government is seeking a contractor to install a microgrid at the specified location. No other details about the specific products, services, or requirements are provided in this document.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C A
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A R
Y
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
G-001
C O
V E
R S
H E
E T
N .T
.S
ERCIP 506498 (FY24) ZONE 6
SOLAR PV and 1.5MW/1.5MWhr BESS INSTALLATION
MICROGRID PROJECT 700 KW
2024-506498
JANUARY 2024
WXXXXX-XX-X-XXX
TRANSATLANTIC EXPEDITIONARY DISTRICT
of Engineers
US Army Corps
PROJECT NO.:
CONTRACT NO.:
ISSUE DATE:
CAMP BUEHRING, KUWAIT
VICINITY MAP
IRAQ
IRAN
KUWAIT
P E
R S
IA
N G
U L F
KUWAIT CITY
KUWAIT BAY
WATERWAY
KHAW AZ ZUBAYR
AL FINTAS
AL FUNAYTIS
AL FUHAYHIL
MINA AL AHMADI
MINA ABD ALLAH
AD DIBAIYAH
AZ ZAWR
AL KHIRAN
AN NUWAYSIB
AL WAFRAH
AS SUBAYHIYAH
AL BURQAN
ASH SHUAYBAH
AL AHMADI
JALIB ASH SHUYUKH
AL JAHRA
AL ABRAQ
MARKAZ HUDUD AS SALMI
AS SALIMIYAHHAWALLI
AD DAWHAH
AR RAWDATAYN
AL ABDALI
MARKAZ HUDUD
CAMP ARIFJAN
SAUDI ARABIA
N.T.S.
PROJECT LOCATION
N
DESCRIPTION
INDEX OF DRAWINGS
SHEET NO.
G-001 COVER SHEET
G-002 GENERAL NOTES, ABBREVIATIONS & STANDARD SYBMOLOGY
GENERAL
ELECTRICAL
E-101 MAIN ELECTRICAL SITE PLAN - 1
E-103
E-104
ELECTRICAL SITE PLAN - 1
ELECTRICAL SITE PLAN - 2
E-105
E-107
TYPICAL SOLAR INVERTER EQUIPMENT LAYOUT
AC COMBINER SWITCHBORAD EQUIPMENT LAYOUT
E-501 PV SYSTEM DETAILS
E-602
E-603
PV SYSTEM ONE-LINE DIAGRAMS
PV SYSTEM ONE-LINE DIAGRAMS
E-604 PV SOLAR ARRAY TYPICAL LAYOUT
E-610 TELECOMMUNICATIONS & MONITORING ONE-LINE DIAGRAM
E-615 GROUNDING PLAN
E-616 UFER GROUNDING DETAIL
E-617 SOLAR SYSTEM GROUNDING PLAN
E-625 SIGNAGE PV SYSTEM
E-626 SIGNAGE - BESS
C-501 FENCE DETAILS
CARPORTS - STRUCTURAL NOTES - SHEET 1 OF 2
CIVIL
STRUCTURAL
E-109
ELECTRICAL SITE PLAN - 3
SIGNAGE - BESSE-627
E-106 ELECTRICAL SITE PLAN - 4
E-110
ELECTRICAL SITE PLAN - 5
E-601 ELECTRICAL ONE-LINE DIAGRAM
E-102 MAIN ELECTRICAL SITE PLAN - 2
S-001
CARPORTS - STRUCTURAL NOTES - SHEET 2 OF 2S-002
CARPORTS - GENERAL PLAN - SHEET 1 OF 2S-101
CARPORTS - PARTIAL FOUNDATION PLAN
S-102
CARPORTS - PARTIAL FRAMING PLAN
S-103
CARPORTS - PARTIAL ELEVATIONS-301
CARPORTS - SECTIONS & DETAILSS-501
TYPICAL EQUIPMENT DETAILS-502
E-108 ELECTRICAL SITE PLAN - 6
CARPORTS - GENERAL PLAN - SHEET 2 OF 2
S-104
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
16 May 2024
W912QR24R0046
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R J O
H N
S O
N P
.E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
G-002
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING CONSTRUCTION.17.
RATING. UL LISTING OF MARKINGS NOT REQUIRED (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT).
RESISTANT MATERIALS SUITABLE FOR THE ENVIRONMENT. UL 696 SHALL BE USED AS A STANDARD FOR WEATHER
MINIMUM 10mm LETTER HEIGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON-BOLD , REFLECTIVE WEATHER
PROVIDE LABELINGS AND MARKINGS FOR ALL EQUIPMENT. LETTERING TO BE RED BACKGROUND, WHITE LETTERING, 16.
ALL NEW UNDERGROUND CONDUITS SHALL BE PVC SCHEDULE 80.15.
REQUIREMENTS IN NEC 705.12, 705.14, 705.L16, & 705.32 SHALL APPLY.
FOR NEW MICROGRID SYSTEM OPERATED IN PARALLEL WITH A PRIMARY SOURCE(S) OF ELECTRICITY, THE 14.
NEW MICROGRID SYSTEM SHALL COMPLY WITH UL 508, 854, AND UL 1703, 1741, 4703, 6703 REQUIREMENTS.13.
PROVIDE SAFETY SIGNAGE PER THE NATIONAL ELECTRICAL CODE AS INDICATED ON SHEET E-625.12.
ALL COMBINER BOXES, DISCONNECTS, PANELS, AND INVERTERS SHALL BE PERMANENTLY IDENTIFIED.11.
NATIONAL CODES.
ALL NEW ELECTRICAL EQUIPMENT SHALL BE BRACED OR ANCHORED IN COMPLIANCE WITH APPLICABLE LOCAL AND 10.
RATING BEFORE THE PENETRATION.
SMOKE WITH APPROVED CABLE & CONDUIT FIRE STOPS OR FIRE RESISTANT SEALANT TO GIVE THE EQUIVALENT FIRE
ALL CONDUIT PENETRATIONS THROUGH FIRE-RATED WALLS SHALL BE SEALED AGAINST THE SPREAD OF FIRE OR 9.
USE-2.
LOCATIONS FOR WIRES IN CONDUIT. CONDUCTORS NOT IN CONDUIT AND ARE EXPOSED TO SUNLIGHT WILL BE TYPE
ALL NEW WIRING SHALL BE THWN-2, RATED FOR 90 DEGREES C, 600V INSULATION SUITABLE FOR WET & DRY 8.
TYPE SUITABLE FOR EXTERIOR INSTALLATION, RATED NEMA 4.
ALL NEW EXTERIOR EQUIPMENT, JUNCTION BOXES, ENCLOSURES AND CONNECTIONS SHALL BE WEATHERPROOF 7.
LABORATORIES (UL) OR LISTED AND CERTIFIED BY A NATIONALLY RECOGNIZED TESTING AUTHORITY.
ALL NEW ELECTRICAL MATERIALS AND EQUIPMENT SHALL BE NEW AND SHALL BE LISTED BY UNDERWRITER'S 6.
(COR), BASE OPERATING SUPPORT INTEGRATOR (BOS-I) AND DEPARTMENT OF PUBLIC WORKS (DPW).
ALL NEW UNDERGROUND WORK SHOULD BE COORDINATED WITH THE CONTRACTING OFFICER REPRESENTATIVE 5.
MICROGRID SYSSTEM INSTALLATION SHALL CONFORM TO NEC ARTICLE 690. 705.12 AND BRITISH STANDARD. 4.
GENERAL SPEC FOR ELECTRICAL INSTALLATION
3.2 MINISTRY OF ELECTRICITY AND WATER (MEW) S-1,
3.1 NATIONAL ELECTRICAL CODE (NEC) 2020
ALL NEW WORK SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE FOLLOWING CODES: 3.
LOCATION OF CONDUIT AND EQUIPMENT IS APPROXIMATE.
THE ELECTRICAL SYSTEM LAYOUTS INDICATED ON THE DRAWINGS ARE GENERALLY DIAGRAMMATIC. THE EXACT 2.
MICROGRID SYSTEM IS TO BE INSTALLED IN INTERACTIVE GRID PARALLEL MODE ONLY. 1.
N .T
.S
S
T A
N D
A R
D S
Y M
B O
L O
G Y
G E
N E
R A
L N
O T
E S
A
B B
R E
V
IA
T
IO
N S
PHOTOVOLTAICPV
PRACTICAL TEST CONDITIONSPTC
PANELPANL
CONDUCTOR PHASE
UNDERGROUND SERVICE ENTRANCE USE-2
UNLESS OTHERWISE NOTEDUON
UNIFORM BUILDING CODEUBC
TRANSFORMERXFMR
WEATHERPROOFWP
WIREW
VOLTV
UNDERGROUNDUG
TYPICALTYP
TOP AND BOTTOMT&B
TELEPHONETEL
SWITCHBOARDSWBD
SWITCHSW
STANDARD TEST CONDITIONSSTC
RIGID STEEL CONDUITRSC
REINFORCED CEMENT CONCRETERCC
RELOCATE(R)
POWERPWR
PHASEPH
PORTLAND CEMENT CONCRETEPCC
PULL BOXPB
NOT TO SCALENTS
NOT IN CONTRACTNIC
NATIONAL ELECTRIC CODENEC
NORMALLY OPENNO
NORMALLY CLOSEDNC
NEW(N)
MOUNTEDMTD
MAIN LUGS ONLYMLO
MISCELLANEOUSMISC
THOUSAND CIRCULAR MILSMCM
MAIN CIRCUIT BREAKERMCB
LIGHTINGLTG
KILOWATT HOURSKWH
KILOWATTSKW
KILOVOLT AMPERESKVA
20A 3P
CB-A1
M
M
PC
P
GENERAL CROSS-REFERENCING SYMBOLS
GENERAL LEGEND
ABBREVIATIONS
A1
DETAIL/SECTION
SCALE:
SUPPLEMENTAL INFORMATION
A2 DETAIL/SECTION
SCALE:99/999
TOP FRONT SIDE
ELEVATION A1
SECTION
SCALE:
SECTION
BUILDING / WALL
DRAWING
SHOWN ON SAME
SECTION CUT W/ VIEW
EXTERIOR ELEVATION
DRAWING
SHOWN ON ANOTHER
SECTION CUT W/ VIEW
A2 99/999A1
A1 A2 99/999
SAME DRAWING
VIEW SHOWN ON
DETAIL SYMBOL W/
ANOTHER DRAWING
VIEW SHOWN ON
DETAIL SYMBOL W/
DRAWING
TITLE ON SAME
SECTION/DETAIL
DRAWING
ANOTHER
TITLE SHOWN ON
SECTION/DETAIL
VIEW SUBTITLE
0 1' 2'
0 1' 2'
0 1' 2'
DWG 2
ELEVATION
INTERIOR
A101
STANDARD REFERENCE BUBBLE
DETAIL NUMBER
SHEET DETAIL IS LOCATED ON
ALL SCALES ARE IN METERS (M) UNLESS OTHERWISE NOTED.2.
AERIAL IMAGE SHOWN FLOWN IN SEPTEMBER 2021 AND MAY NOT REFLECT CURRENT SITE CONDITIONS.1.
GENERAL NOTES
ELECTRICAL NOTES:
Sc
J
XX
X
L L
EMODU
TAIC PHOTOVO
INVERTER
DISCONNECT
FUSED DISCONNECT
COMBINER BOX
20A, 3 POLE
CIRCUIT BREAKER
METER
TRANSFORMER
MOTOR
LIGHT FIXTURE
UNDER CANOPY
PHOTOCELL
PULL BOX
JUCTION BOX
RECEPTACLE
SWITCH
DATA OUTLET
CONDUIT RUN
LOW VOLTAGE
UNDERGROUND CONDUIT
STTING PATH
PER NEC
GROUNDING
HR CONDUIT
HR UNDERGROUND
OUT SYMBOL
DETAIL CALL
SPLICE OR TAP
MEDIUM VOLTAGE
UNDERGROUND CONDUIT
COMMUNICATIONS
UNDERGROUND CONDUIT
GENERAL NOTES:
STRUCTURAL NOTES:
4.
1.
WEIGHTS AND FULL ROOF LIVE LOAD IN ALL APPLICABLE LOAD COMBINATIONS.
THE SUPER IMPOSED DL FROM PV SOLAR PANELS MUST BE CONSIDERED IN ADDITION TO ALL OTHER STRUCTURAL SELF-6.
SEISMIC DESIGN CATEGORY: “D”
S1: 0.27g Ss: 0.57g
MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS:
COMPONENT IMPORTANCE FACTOR: 1.25
RISK CATEGORY: “III”
SEISMIC LOAD (UFC 3-301-01 AND ASCE 7-16 SECTION 13.6.12):
RISK CATEGORY: “III”
EXPOSURE CATEGORY: “C”
ULTIMATE DESIGN WIND SPEED V= 177 kph (110 mph)
WIND LOAD (UFC 3-301-01 AND ASCE 7-16 CHAPTER 29-31):
0 kPa (0 PSF)
SNOW LOAD:
ROOF: 1.0 kPa (20 PSF)
LIVE LOAD (UFC 1-201-1, ASCE 7-16, AND UFC 3-301-01):
PV SOLAR PANELS
STRUCTURE SELF-WEIGHT
DEAD LOADS:
FASTENING MUST BE DESIGNED TO MEET THE FOLLOWING:
PV PANEL SUPPORTING SYSTEM MUST BE DESIGNED IN ACCORDANCE WITH UFC 3-301-01. PV PANEL SUPPORTING SYSTEM 5.
ON THE ROOF DURING INSTALLATION.
UNSUPPORTED ROOF DECKS TO PREVENT ROOF DAMAGES. THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY DAMAGES WHEN WORKING ON THE ROOF, WALKING IS ALLOWED ONLY ON THE PURLINS. AVOID STEPPING DIRECTLY ON THE
AND MATERIAL STATCKING TO BE LESS THAN THE ROOF LIVE LOAD.
THE DESIGN ROOF LIVE LOAD OF THE WAREHOUSE IS 20 PSF (1.0 kPa) CONTRACTOR MUST LIMIT PERSONNEL, EQUIPEMENT, 3.
COMPLETELY BE SEALED.
PENETRATIONS TO FULLEST EXTENT POSSIBLE. ANY ROOF PENETRATIONS REQUIRED FOR THE INSTALLATION MUST TO THE EXISTING PURLINS OR ROOF FRAMING IMMEDIATELY UNDER THE METAL ROOF DECKS. AVOID EXCESSIVE ROOF
THE PV PANEL SUPPORTING SYSTEM MUST DIRECTLY BE FASTENED BALLASTED MOUNTING SYSTEMS ARE NOT PERMITTED.
THE PV PANEL SUPPORTING SYSTEM MUST BE LIGHT WEIGHT AND CORROSION RESISTIVE. PER UFC 3-110-03 ROOFING, 2.
FOR APPROVAL.
CONTRACTOR MUST PROVIDE TO THE GOVERNMENT A PROPOSED PHOTOVOLTAIC (PV) SOLAR PANEL SUPPORTING SYSTEM
EXISTING WAREHOUSES AND SHADE STRUCTURE:
JUNCTION BOXJ-BOX
INVERTERINV
HORSE POWERHP
HIGH INTENSITY DISCHARGEHID
GALVANIZED RIGID STEEL CONDUITGRC
GROUND OR GROUNDINGGND
GROUND FAULT CKT INTERRUPTERGFCI
GROUNDING ELECTRODE CONDUCTORGEC
FIRE ALARM CONTROL PANELFACP
EQUIPMENTEQMT
EMERGENCYEM
EQUIPMENT GROUNDEG
EQUIPMENT GROUNDING CONDUCTOREGC
ELECTRICAL CONTRACTOREC
EXISTING(E)
DRAWINGDWG
DC COMBINER BOXDCCB
DIRECT CURRENTDC
DATA ACQUISITION SYSTEMDAS
DISCONNECTD
COPPERCU
CONDUIT ONLYC.O.
CENTER LINECL
CIRCUITCKT
COMBINER BOXCB
CONDUIT/RACEWAYC
BUILDINGBLDG
BARE COPPERBC
AMERICAN WIRE GUAGEAWG
AUTOMATIC TRANSFER SWITCHATS
AMP SWITICHAS
ARCHITECTARCH
ALUMINUMAL
AMP INTERRUPTER CAPAClTYAIC
ABOVE FINISH FLOORAFF
AVAILABLE FAULT CURRENTAFC
AMP FUSEAF
AC COMBINER BOXACCB
ALTERNATING CURRENTAC
AMPERESA
1.
DOES NOT INCLUDE THE WEIGHT OF HUNG EQUIPMENT WEIGHING 25 KG OR MORE.
WEIGHT OF ADDITIONAL PERMANENT MATERIALS OTHER THAN BUILDING SYSTEM. THIS ALLOWANCE COLLATERAL LOAD OF 0.50 kPA MUST BE APPLIED TO THE ENTIRE STRUCTURE TO ACCOUNT FOR THE
COLLATERAL LOADS6.4
SEISMIC DESIGN CATEGORY: "D"
SITE CLASS: "D"
0.37gS1:
0.51gSs:
DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS:
0.27gS1:
0.57gSs:
MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS:
SEISMIC IMPORTANCE FACTOR, le: 1.00
RISK CATERGORY: II
EARTHQUAKE LOADS (UFC 1-201-01, ASCE 7-16, AND UFC 3-301-01): 6.3
RISK CATEGORY: II
EXPOSURE CATEGORY : "C"
Vasd: 137 km/h (85)NOMINAL DESIGN WIND SPEED Vult: 177 km/h (110 MPH)ULTIMATE DESIGN WIND SPEED
DESIGN WIND SPEED
WIND LOADS (UFC 1-201-01, ASCE 7-16, AND UFC 3-301-01):6.2
0 kPa (0 PSF)
SNOW LOADS (UFC 1-201-01, ASCE 7-16, AND UFC 3-301-01)6.1.3.
STRUCTURE SELF WEIGHT
DEAD LOADS6.1.2.
0.96 kPa (20 PSF)ROOF:
LIVE LOAD (UFC 1-201-01, ASCE 7-16, UFC 3-301-01)6.1.1.
GRAVITY LOADS 6.1.
TO MEET THE FOLLOWING:
THE FACILITY MUST BE DESIGNED AT A CONSTRUCTION LEVEL OF "SEMI-PERMANENT" AND MUST BE DESIGNED
301-01 STRUCTURAL ENGINEERING.
IN SUPPORT OF MILITARY OPERATIONS, THE INTERNATIONAL BUILDING CODE (IBC) 2018 EDITION, AND UFC 3- THE STRUCTURE MUST BE DESIGNED IN ACCORDANCE WITH UFC 1-201-01 NON PERMANENT DOD FACILITIES 6.
EXTEND AWAY FROM THE FACE OF THE BUILDING A MINIMUM OF 150mm.
GROUND LEVEL AND MUST BE FITTED WITH IN-KIND CURVED GUTTER ELBOW FITTINGS THAT
THE CORNER LOCATIONS OF THE BUILDING DOWN SPOUTS MUST TERMINATE 100mm ABOVE
SPOUTS PER BUILDING SIDE IS REQUIRED. THE LOCATION OF EACH DOWN SPOUT MUST BE AT
CROSS SECTION DIMENSIONS OF 100mm WIDE AND 75mm DEEP. A MINIMUM OF TWO DOWN
DOWN SPOUTS: DOWN SPOUTS MUST BE RIBBED RECTANGULAR COLD-FORMED WITH MINIMUM
AND COVER THE ENTIRE SPAN OF THE ROOF LENGTH.
OF 150mm WIDE BY 150mm DEEP. EAVE GUTTERS MUST BE ON BOTH SIDES OF THE GABLE ROOF
EAVE GUTTERS: GUTTERS MUST BE COLD-FORMED WITH MINIMUM CROSS SECTION DIMENSIONS
REQUIREMENTS ARE AS FOLLOWS:
GUTTERS AND DOWN SPOUT MATERIALS MUST BE THE SAME MATERIAL OF THE ROOF PANELS. OTHER MANUFACTURER AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
SHADE CANOPY. IF THE SHADE CANOPY IS MBS, THESE ITEMS MUST BE PROVIDED AND BY THE MBS GUTTERS, DOWN SPOUTS, AND THE RESPECTIVE INSTALLATION HARDWARE MUST BE PROVIDED FOR THE 5.
BE SUBMITTED FOR REVIEW AND APPROVAL PRIOR OT ERECTION.
PROTECTION AND FINISH, A PAINTING PLAN INCLUDING WORK PROCEDURE AND PRODUCT SELECTION MUST SECTION 05 12 00. IF THE CONTRACTOR DESIRES TO HAVE THE STRUCTURE PAINTED INSTEAD FOR SURFACE ALL OF THE STRUCTURAL STEEL MEMBERS MUST BE GALVANIZED IN ACCORDANCE WITH SPECIFICATION 4.
ANGLE OF 85 DEGREES IN ACCORDANCE WITH ASTM D523.
OF ROOF AND WALL PANELS MUST HAVE A LIGHT REFLECTANCE OF NOT MORE THAN 10, MEASURED AT AN ALUMINUM/ZINC-COATED STEEL (IN ACCORDANCE WITH ASTM A792/A792M, AZ55). THE EXTERNAL SURFACE
COATING CLASS Z350 OR ASTM A653/A653M, SQ, GRADE 33, COATING CLASS Z350) OR A755/A755M, ROOF AND WALL PANELS MUST BE FABRICATED OF ZINC-COATED STEEL (IN ACCORDANCE WITH ASTM 3.
16mm DIAMETER COLUMN ANCHOR BOLTS:
16mm THICKCOLUMN BASE PLATES:
5mm THICKBRACINGS:
5mm THICKGIRDERS AND COLUMNS:
MINIMUM THICKNESS OF STRUCTURAL STEEL MEMBERS MUST NOT BE LESS THAN THE FOLLOWING MINIMUMS:2.
EFER TO DWGS. S-001 AND S-002 FOR STRUCTURAL NOTES, UNLESS OTHERWISE NOTED BELOW. R
AC COMBINER SWITCHBOARD AND BESS SHADE CANOPY:
REFER TO DWGS. S-001 AND S-002 FOR STRUCTURAL NOTES.
NEW CARPORT STRUCTURE:
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
E-101
S
IT
E P
L A
N
M A
IN
E
L E
C T
R
IC
A L
:7
NORTH
PLAN
07M 70M35M35M 14M
SCALE: 1 : 700
E X
IS
T
IN
G
G R
A V
E L
R O
A D
T A
Y L
O R
R O
A D
TRUMAN STREET
EXISTING FENCE
FENCE
EXISTING
ARTC LOOP
E L E
V A T
E D T
R A
IL
E R
FENCE
EXISTING
T T -6
TT
-60
T T
-6
T T
-6
T T
-6
T T
-6
T T
-6
T T
-6
/T
T T
-6
T T
-6
T T
-6
T T
-6
T T
-6
T
T
T-6017
T T -6
T T -6
T T -6
H001 H003
H005 H007
H009
H001
H001
H001
H001
H001
H001
H001
H001
H008
H006
H004
H002
H002
H002
H001
H002
H002
H002
H003
H002
GATE
EXISTING
GATE
EXISTING
H002
H002
H002 5 H002
T
T
EXISTING GATE
B6
B6
B6
B606
PROPOSED CARPORT-1
B5
T-B
B4 2T-6
H003
H003
H003
H003
H003
H003
T6
SS
SS
T6
SS6093
T
T
T
T
(TYP)
CABLES
BURIED
DIRECT
PROPOSED BESS
CABLES (TYP)
DIRECT BURIED
SWITCHBOARD
AC COMBINER
PROPOSED
TRANSFORMER
PROPOSED
MSB
PROPOSED
GEN (TYP.)
EXISTING
GENERATOR
EXISTING
MV CABLES
PROPOSED
ELECTRICAL BOX
EXISTING
GENERATOR
1.5MW
PROPOSED
MATCH LINE SEE SHEET E-102
G-1A
G2G3
G4
G5
G6
G7
G8
G9
G10
MATCH LINE SEE SHEET E-102
G11
G18
PROPOSED C
ARPORT-3
GENERAL NOTES
INSTALLED ON CONCRETE PADS.
EXTERIOR ELECTRICAL EQUIPMENT SHALL BE 6.
USE-2 TYPE.
DIRECT BURRIED TYPE. DC CONDUCTIORS SHALL BE
LOW VOLTAGE (600V) AC CONDUCTORS SHALL BE 5.
SERIES.
PHOTOVOLTAIC STRINGS HAVE 11 SOLAR MODULES IN 4.
CONDUCTOR SIZES.
REFER TO SINGLE LINE FOR CONDUIT AND 3.
TO AVOID ANY EXISTING UTILITIES.
GROUND WORK WITH THE APPROPRIATE AUTHORITIES
SHALL COORDINATE AND CONFIRM ALL UNDER-
VOLTAGE CABLES IN WORK AREA. CONTRACTOR
THERE ARE UNDERGROUND WATER LINES AND LOW 2.
AND A NEW CAR PORT AT CAMP BUEHRING.
EQUIPMENT ON THE ROOF AN EXISTING BUILDINGS
THIS PROJECT CALLS FOR INSTALLING PHOTOVOLTAIC 1.
9.
GROUNDED IN ACCORDANCE WITH THE NEC 2020.
ELECTRICAL DISTRIBUTION EQUIPMENT MUST BE 8.
COPPER, XLPE/SWA/PVC.
DIRECT BURRIED CABLES MUST BE AROUNDED 7.
MAYBE PARTY OF THE PERIMETER SEPARATION.
STRUCTURE. AN ADJACENT FACILITY EXTERIOR WALL
PROVIDED NOT LESS THAN 100 FEET FROM THE
INSTALLATION'S FACILITY STANDARDS MUST BE
FENCE OR WALL IN ACCORDANCE WITH THE
OR AN IDENTIFIED OUTDOOR USE AREA. A PERIMETER
THAN 100 FEET (30 M) TO AN OCCUPIED STRUCTURE
LITHIUM BATTERY MUST BE LOCATED NO CLOSER
LOCATION. UNOCCUPIED STRUCTURES HOUSING 11.
GENERAL ARRANGEMENT OF THE SYSTEMWORK.
DRAWINGS ARE DIAGRAMMATIC AND INDICATES THE 10.
AND NEW MTS'S AS NEEDED.
THE EXISTING MDP's FED BY THE SPOT GENERATORS
INSTALLING NEW CONDUCTORS FROM THE MSB TO
EXISTING SPOT GENERATORS AT THE ARTIC SITE BY
THE CONTRACTOR SHALL PICK THE LOADS OF 18
TRUMAN STREET
A1
SCALE: 1:700
MAIN ELECTRICAL SITE PLAN - CAMP BUEHRING
M A
R S
H A
L L
D R
IV
E
SHEET SYMBOLS
12KV RATED
ARMORED AND PVC SHEATHED,
SCREENED, STEEL WIRE
INSULATED, COPPER TAPE
1x3C-300MM^2, ALUMINUM, XLPE
MV UNDERGROUND CABLE
GENERATORS
SECTIONALIZING BOX
DC SOLAR CABLES
AC POWER CABLES
AC INVERTER CABLES
PVC SCH. 80 ENCASED IN CONCRETE
SB
PROPOSED C
ARPORT-2
LAYDOWN AREA
CONTRACTOR
G-1B
Gx
(SAM-
T)TT
-60
ARTC L
OOP
AIR
BORNE R
OAD
ARTC LOOP
A R
T C L
O O
P
B
B
B
B
B56
A
IR
A
S S
A U
L T R
O A
D
ARTC L
OOP
MTS
291A
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
E-102
S
IT
E P
L A
N
M A
IN
E
L E
C T
R
IC
A L
:7
MATCH LINE SEE SHEET E-101
T A
Y L
O R
R O
A D
EXISTING FENCE
STRUCTURES
EXISTING
H001 H003
H005 H007
H009
H001
H001
H001
H001
H001
H001
H001
H001
H008
H006
H004
H002
H002
EXISTING GATE
T
T
TT6
B608
B606
RVTT
EXISTING GRAVEL ROAD
B5
T-B
B4 2T-6
H003
H003
H003
H003
H003
H003
T6
B605
SS
T -6
T -6
B6015
T T
SEE DWG E-104
EQUIPMENT PAD (TYP)
PV INVERTER &
E X
IS
T
IN
G
G R
A V
E L
R O
A D
G11
G17
MATCH LINE SEE SHEET E-101
G12
G13
G14
G-16A
G15
SS603
TT-601
T6040
T6041
SS6090
T T
-6
T
T T
T T
T6064
T6063
TRAINING VILLAGE
ARTC
9.
GROUNDED IN ACCORDANCE WITH THE NEC 2020.
ELECTRICAL DISTRIBUTION EQUIPMENT MUST BE 8.
COPPER, XLPE/SWA/PVC.
DIRECT BURRIED CABLES MUST BE AROUNDED 7.
INSTALLED ON CONCRETE PADS.
EXTERIOR ELECTRICAL EQUIPMENT SHALL BE 6.
USE-2 TYPE.
DIRECT BURRIED TYPE. DC CONDUCTIORS SHALL BE
LOW VOLTAGE (600V) AC CONDUCTORS SHALL BE 5.
SERIES.
PHOTOVOLTAIC STRINGS HAVE 11 SOLAR MODULES IN 4.
CONDUCTOR SIZES.
REFER TO SINGLE LINE FOR CONDUIT AND 3.
TO AVOID ANY EXISTING UTILITIES.
GROUND WORK WITH THE APPROPRIATE AUTHORITIES
SHALL COORDINATE AND CONFIRM ALL UNDER-
VOLTAGE CABLES IN WORK AREA. CONTRACTOR
THERE ARE UNDERGROUND WATER LINES AND LOW 2.
AND A NEW CAR PORT AT CAMP BUEHRING.
EQUIPMENT ON THE ROOF AN EXISTING BUILDINGS
THIS PROJECT CALLS FOR INSTALLING PHOTOVOLTAIC 1.
GENERAL ARRANGEMENT OF THE SYSTEMWORK.
DRAWINGS ARE DIAGRAMMATIC AND INDICATES THE 10.
AND NEW MTS'S AS NEEDED.
THE EXISTING MDP's FED BY THE SPOT GENERATORS
INSTALLING NEW CONDUCTORS FROM THE MSB TO
EXISTING SPOT GENERATORS AT THE ARTIC SITE BY
THE CONTRACTOR SHALL PICK THE LOADS OF 18
GENERAL NOTES
12KV RATED
ARMORED AND PVC SHEATHED,
SCREENED, STEEL WIRE
INSULATED, COPPER TAPE
1x3C-300MM^2, ALUMINUM, XLPE
MV UNDERGROUND CABLE
GENERATORS
SECTIONALIZING BOX
DC SOLAR CABLES
AC POWER CABLES
AC INVERTER CABLES
PVC SCH. 80 ENCASED IN CONCRETE
SHEET SYMBOLS
SB
G10
G18
G L
A S
S H
O U
S E
SS 6091
NORTH
PLAN
07M 70M35M35M 14M
SCALE: 1 : 700
A1
SCALE: 1:700
MAIN ELECTRICAL SITE PLAN - CAMP BUEHRING
PROPOSED C
ARPORT 2
PROPOSED C
ARPORT-3
G-16B
Gx
ARTC L
OOP
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
E-103
E L
E C
T R
IC
A
L S
IT
E
P L
A N
:3
WHEN WORKING ON THE ROOFC.
ON EACH SIDE.
END OF BUILDING AND THREE SIGNS EQUALLY SPACED
SEE E-625, SIGN DETAIL #15. PLACE ONE SIGN ON EACH
ACCESS IS LIMITED TO ONLY (2) PERSONS AT A TIME",
WALLS OF BUILDINGS TO INDICATE "ROOF MAINTENANCE
CONTRACTOR SHALL PLACE SIGNAGE ON EXTERIOR B.
USED IN THE BUILDING ROOF DESIGN.
MATERIAL STACKING TO BE LESS THAN THE LIVE LOAD
CONTRACTOR SHALL LIMIT PERSONNEL, EQUIPMENT, & A.
STRUCTURE PER STRUCTURAL NOTE 2 ON DWG. G-002.
THE PV PANEL SUPPORTING SYSTEM TO THE EXISTING
SYSTEM PER THE PANELS' MANUFACTURER. INSTALL
INSTALL SOLAR PANELS TO PV PANEL SUPPORTING D.
ROOF DURING INSTALLATION.
FULLY RESPONSIBLE FOR ANY DAMAGES ON THE
PREVENT ROOF DAMAGES. THE CONTRACTOR IS
DIRECTLY ON THE UNSUPPORTED ROOF DECKS TO
ALLOWED ONLY ON THE PURLINS. AVOID STEPPING
, WALKING IS
PLAN NOTES
A1
SCALE: 1:300
ELECTRICAL SITE PLAN - 1
NORTH
PLAN
SCALE: 1 : 300
3 301515
GENERAL NOTESSHEET SYMBOLS
T T
-6
T T
-6
T T
-6
T T
-6 /T
T T
-6
T T
-6
MANUFACTURER'S INSTALLATION MANUAL.
SOLAR INVERTERS TO BE INSTALLED PER 6.
USE-2 TYPE.
DIRECT BURRIED TYPE. DC CONDUCTORS SHALL BE
LOW VOLTAGE (600V) AC CONDUTORS SHALL BE 5.
INSTALLED ON CONCRETE PADS.
EXTERIOR ELECTRICAL EQUIPMENT SHALL BE 4.
NEMA 4 OR HAVE AN IP 65 RATING.
ELECTRICAL ENCLOSURE CABINETS SHALL BE RATED 3.
CONDUCTOR SIZES.
REFER TO SINGLE LINE FOR CONDUIT AND 2.
LOCATIONS OF EXISTING UTILITIES ARE ESTIMATED.
AUTHORITIES TO AVOID ANY EXISTING UTILITIES.
UNDERGROUND WORK WITH THE APPROPRIATE
SHALL COORDINATE AND CONFIRM ALL ALL
VOLTAGE CABLES IN WORK AREA. CONTRACTOR
THERE ARE UNDERGROUND WATER LINES AND LOW 1.
PROPOSED CARPORT-1
T T
-6
FENCE
EXISTING
GENERATOR
EXISTING
TRUMAN STREET
TRANSFORMER
PROPOSED
GENERATOR
PROPOSED 1.5MW
MSB
PROPOSED
GATE
EXISTING
GENERATORS
DC SOLAR CABLES
AC POWER CABLES
AC INVERTER CABLES
IN CONCRETE
PVC SCH. 80 ENCASED
LAYDOWN AREA
CONTRACTOR
ARRAY 1
G3
Gx
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
E-104
E L
E C
T R
IC
A
L S
IT
E
P L
A N
:3
VENTS FROM DAMAGE DURING CONSTRUCTION.
EXISTING RIDGE VENTS TO REMAIN. PROTECT RIDGE 7.
MANUFACTURER'S INSTALLATION MANUAL.
SOLAR INVERTERS TO BE INSTALLED PER 6.
USE-2 TYPE.
DIRECT BURRIED TYPE. DC CONDUCTORS SHALL BE
LOW VOLTAGE (600V) AC CONDUTORS SHALL BE 5.
INSTALLED ON CONCRETE PADS.
EXTERIOR ELECTRICAL EQUIPMENT SHALL BE 4.
NEMA 4 OR HAVE AN IP 65 RATING.
ELECTRICAL ENCLOSURE CABINETS SHALL BE RATED 3.
CONDUCTOR SIZES.
REFER TO SINGLE LINE FOR CONDUIT AND 2.
LOCATIONS OF EXISTING UTILITIES ARE ESTIMATED.
AUTHORITIES TO AVOID ANY EXISTING UTILITIES.
UNDERGROUND WORK WITH THE APPROPRIATE
SHALL COORDINATE AND CONFIRM ALL ALL
VOLTAGE CABLES IN WORK AREA. CONTRACTOR
THERE ARE UNDERGROUND WATER LINES AND LOW 1.
NORTH
PLAN
GENERAL NOTES
SCALE: 1 : 200
2 201010A1
SCALE: 1:200
ELECTRICAL SITE PLAN - 2
BUILDING 611
ARRAY 1
ARRAY 2
BUILDING 610
ARRAY 1
ARRAY 2
BUILDING 608
ARRAY 1
ARRAY 2
WHEN WORKING ON THE ROOFC.
ON EACH SIDE.
END OF BUILDING AND THREE SIGNS EQUALLY SPACED
SEE E-625, SIGN DETAIL #15. PLACE ONE SIGN ON EACH
ACCESS IS LIMITED TO ONLY (2) PERSONS AT A TIME",
WALLS OF BUILDINGS TO INDICATE "ROOF MAINTENANCE
CONTRACTOR SHALL PLACE SIGNAGE ON EXTERIOR B.
USED IN THE BUILDING ROOF DESIGN.
MATERIAL STACKING TO BE LESS THAN THE LIVE LOAD
CONTRACTOR SHALL LIMIT PERSONNEL, EQUIPMENT, & A.
STRUCTURE PER STRUCTURAL NOTE 2 ON DWG. G-002.
THE PV PANEL SUPPORTING SYSTEM TO THE EXISTING
SYSTEM PER THE PANELS' MANUFACTURER. INSTALL
INSTALL SOLAR PANELS TO PV PANEL SUPPORTING D.
ROOF DURING INSTALLATION.
FULLY RESPONSIBLE FOR ANY DAMAGES ON THE
PREVENT ROOF DAMAGES. THE CONTRACTOR IS
DIRECTLY ON THE UNSUPPORTED ROOF DECKS TO
ALLOWED ONLY ON THE PURLINS. AVOID STEPPING
, WALKING IS
PLAN NOTES
SHEET SYMBOLS
RECOMBINER
MASTER
(TYP)
DISCONNECT
PV
(TYP)
NEW COMBINER
PV INVERTER (TYP)
(TYP)
DISCONNECT
PV
RECOMBINER
MASTER
(TYP)
NEW COMBINER
PV INVERTER (TYP)
PV DISCONNECT (TYP)
RECOMBINER
MASTER
(TYP)
NEW COMBINER
PV INVERTER (TYP)
AIRBORNE ROAD
SS611
A
IR
A
S S
A U
L T R
O A
D
A R
T C L
O O
P
T6045
ACCORDANCE TO IEC 62305-3.
THE DC AND AC SIDE THE INVERTER(S) IN
APPLY TYPE 1+2 SPDs (SURGE PROECTION DEVICE) ON H.
IEC 62561-1.
MUST MEET THE REQUIREMENTS IN ACCORDANCE TO
THE PV-SYSTEM AND COMBINATION WITH THE CLAMPS
OF THE PV-SYSTEM. THE MOUNTING STRUCTURE OF
BETWEEN THE LPS AND THE MOUNTING STRUCTURE
USE APPROVED CLAMPS TO MAKE THE CONNECTION G.
BONDING, USING 16mm2 CU.
CONNECTED FOR LIGHTNING EQUIPOTENTIAL
OF THE PV-SYSTEM AND THE LPS MUST BE
DISTANCE IS NOT KEPT (S<50cm): THE SUBSTRUCTURE
PROTECTION AREA OF THE LPS AND THE SEPARATION
IN CASE THE PV-SYSTEM IS PLACED WITHIN THE F.
6mm2 CU IN ACCORDANCE TO EN 62305-3.
BONDING OF THE PV-SYSTEM IS REQUIRED, USING
CONNECTED. ONLY FUNCTIONAL EQUIPOTENTIAL
THE PV-SYSTEM AND THE LPS SHOULD NOT BE
SYSTEM IS KEPT (S>50CM): THE SUBSTRUCTURE OF
DISTANCE BETWEEN THE PV-SYSTEM AND THE LPS-
PROTECTION AREA OF HTE LPS AND THE SEPARATION
IN CASE THE PV-SYSTEM IS PLACED WITHIN THE E.
LIGHTNING NOTES
GENERATORS
DC SOLAR CABLES
AC POWER CABLES
AC INVERTER CABLES
IN CONCRETE
PVC SCH. 80 ENCASED
G6
G7
G8
Gx
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
E-105
E L
E C
T R
IC
A
L S
IT
E
P L
A N
:3
NORTH
PLAN
SCALE: 1 : 200
2 201010
GENERAL NOTES
A1
SCALE: 1:200
ELECTRICAL SITE PLAN - 3
BUILDING 606
ARRAY 1
ARRAY 2ARRAY 3
VENTS FROM DAMAGE DURING CONSTRUCTION.
EXISTING RIDGE VENTS TO REMAIN. PROTECT RIDGE 7.
MANUFACTURER'S INSTALLATION MANUAL.
SOLAR INVERTERS TO BE INSTALLED PER 6.
WILL BE TYPE USE-2.
NOT IN CONDUIT AND ARE EXPOSED TO SUNLIGHT
LOCATIONS FOR WIRES IN CONDUIT. CONDUCTORS
C, 600V INSULATION SUITABLE FOR WET & DRY
WIRING SHALL BE THWN-2, RATED FOR 90 DEGREES 5.
INSTALLED ON CONCRETE PADS.
EXTERIOR ELECTRICAL EQUIPMENT SHALL BE 4.
NEMA 4 OR HAVE AN IP 65 RATING.
ELECTRICAL ENCLOSURE CABINETS SHALL BE RATED 3.
CONDUCTOR SIZES.
REFER TO SINGLE LINE FOR CONDUIT AND 2.
LOCATIONS OF EXISTING UTILITIES ARE ESTIMATED.
AUTHORITIES TO AVOID ANY EXISTING UTILITIES.
UNDERGROUND WORK WITH THE APPROPRIATE
SHALL COORDINATE AND CONFIRM ALL ALL
VOLTAGE CABLES IN WORK AREA. CONTRACTOR
THERE ARE UNDERGROUND WATER LINES AND LOW 1.
WHEN WORKING ON THE ROOFC.
EACH SIDE.
OF BUILDING AND THREE SIGNS EQUALLY SPACED ON
E-625, SIGN DETAIL #15. PLACE ONE SIGN ON EACH END
ACCESS IS LIMITED TO ONLY (2) PERSONS AT A TIME", SEE
WALLS OF BUILDINGS TO INDICATE "ROOF MAINTENANCE
CONTRACTOR SHALL PLACE SIGNAGE ON EXTERIOR B.
USED IN THE BUILDING ROOF DESIGN.
MATERIAL STACKING TO BE LESS THAN THE LIVE LOAD
CONTRACTOR SHALL LIMIT PERSONNEL, EQUIPMENT, & A.
STRUCTURE PER STRUCTURAL NOTE 2 ON DWG. G-002.
PV PANEL SUPPORTING SYSTEM TO THE EXISTING
SYSTEM PER THE PANELS' MANUFACTURER. INSTALL THE
INSTALL SOLAR PANELS TO PV PANEL SUPPORTING D.
ROOF DURING INSTALLATION.
FULLY RESPONSIBLE FOR ANY DAMAGES ON THE
PREVENT ROOF DAMAGES. THE CONTRACTOR IS
DIRECTLY ON THE UNSUPPORTED ROOF DECKS TO
ALLOWED ONLY ON THE PURLINS. AVOID STEPPING
, WALKING IS
PLAN NOTES
SHEET SYMBOLS
RECOMBINER
MASTER
PV INVERTER (TYP)
(TYP)
NEW COMBINER
(TYP)
DISCONNECT
PV
A R
T C L
O O
P B605
STRUCTURES
EXISTING
FENCE
EXISTING
GENERATORS
DC SOLAR CABLES
AC POWER CABLES
AC INVERTER CABLES
IN CONCRETE
PVC SCH. 80 ENCASED
G10
G11
Gx
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
E-106
E L
E C
T R
IC
A
L S
IT
E
P L
A N
-4
:3
NORTH
PLAN
SCALE: 1 : 200
2 201010E1
SCALE: 1:200
ELECTRICAL SITE PLAN - 4
GENERAL NOTES
RVTT
ARRAY 2
ARRAY 3
ARRAY 1
780, CHAPTER 12 PROTECTION FOR XOLAR ARRAYS.
EXISTING LIGHTNING PROTECTION IAW THE NFPA
SOLAR (PHOTOVOLATIC AND TERMAL) PANELS WITH
CONTRACTOR MUST INSTALL ROOF-MOUNTED 8.
VENTS FROM DAMAGE DURING CONSTRUCTION.
EXISTING RIDGE VENTS TO REMAIN. PROTECT RIDGE 7.
MANUFACTURER'S INSTALLATION MANUAL.
SOLAR INVERTERS TO BE INSTALLED PE 6.
WILL BE TYPE USE-2.
NOT IN CONDUIT AND ARE EXPOSED TO SUNLIGHT
LOCATIONS FOR WIRES IN CONDUIT. CONDUCTORS
C, 600V INSULATION SUITABLE FOR WET & DRY
WIRING SHALL BE THWN-2, RATED FOR 90 DEGREES 5.
INSTALLED ON CONCRETE PADS.
EXTERIOR ELECTRICAL EQUIPMENT SHALL BE 4.
NEMA 4 OR HAVE AN IP 65 RATING.
ELECTRICAL ENCLOSURE CABINETS SHALL BE RATED 3.
CONDUCTOR SIZES.
REFER TO SINGLE LINE FOR CONDUIT AND 2.
LOCATIONS OF EXISTING UTILITIES ARE ESTIMATED.
AUTHORITIES TO AVOID ANY EXISTING UTILITIES.
UNDERGROUND WORK WITH THE APPROPRIATE
SHALL COORDINATE AND CONFIRM ALL ALL
VOLTAGE CABLES IN WORK AREA. CONTRACTOR
THERE ARE UNDERGROUND WATER LINES AND LOW 1.
C.
SIDE.
BUILDING AND THREE SIGNS EQUALLY SPACED ON EACH
SIGN DETAIL #15. PLACE ONE SIGN ON EACH END OF
LIMITED TO ONLY (2) PERSONS AT A TIME", SEE E-625,
WALLS OF BUILDINGS TO INDICATE "ROOF ACCESS IS
CONTRACTOR SHALL PLACE SIGNAGE ON EXTERIOR B.
USED IN THE BUILDING ROOF DESIGN.
MATERIAL STACKING TO BE LESS THAN THE LIVE LOAD
CONTRACTOR SHALL LIMIT PERSONNEL, EQUIPMENT, & A.
SHADE STRUCTURE IS 10 METER HEIGHT. E.
STRUCTURE PER STRUCTURAL NOTE 2 ON DWG. G-002.
PV PANEL SUPPORTING SYSTEM TO THE EXISTING
SYSTEM PER THE PANELS' MANUFACTURER. INSTALL THE
INSTALL SOLAR PANELS TO PV PANEL SUPPORTING D.
INSTALLATION.
FOR ANY DAMAGES ON THE ROOF DURING
DAMAGES. THE CONTRACTOR IS FULLY RESPONSIBLE
THE UNSUPPORTED ROOF DECKS TO PREVENT ROOF
ONLY ON THE PURLINS. AVOID STEPPING DIRECTLY ON
WHEN WORKING ON THE ROOF, WALKING IS ALLOWED
PLAN NOTES
SHEET SYMBOLS
RECOMBINER
MASTER
(TYP)
PV INVERTER
(TYP)
NEW COMBINER
(TYP)
DISCONNECT
PV
TT6076
AIRBORNE ROAD
STRUCTURE
EXISTING
STRUCTURES
EXISTING
FENCE
EXISTING
FENCE
EXISTING
GENERATORS
DC SOLAR CABLES
AC POWER CABLES
AC INVERTER CABLES
IN CONCRETE
PVC SCH. 80 ENCASED
PROPOSED CARPORT - 2
ARRAY 2
G12
G13
Gx
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
E-107
E L
E C
T R
IC
A
L S
IT
E
P L
A N
-5
:3
NORTH
PLAN
SCALE: 1 : 200
2 201010E1
SCALE: 1:200
ELECTRICAL SITE PLAN - 5
GENERAL NOTES
VENTS FROM DAMAGE DURING CONSTRUCTION.
EXISTING RIDGE VENTS TO REMAIN. PROTECT RIDGE 7.
MANUFACTURER'S INSTALLATION MANUAL.
SOLAR INVERTERS TO BE INSTALLED PE 6.
WILL BE TYPE USE-2.
NOT IN CONDUIT AND ARE EXPOSED TO SUNLIGHT
LOCATIONS FOR WIRES IN CONDUIT. CONDUCTORS
C, 600V INSULATION SUITABLE FOR WET & DRY
WIRING SHALL BE THWN-2, RATED FOR 90 DEGREES 5.
INSTALLED ON CONCRETE PADS.
EXTERIOR ELECTRICAL EQUIPMENT SHALL BE 4.
NEMA 4 OR HAVE AN IP 65 RATING.
ELECTRICAL ENCLOSURE CABINETS SHALL BE RATED 3.
CONDUCTOR SIZES.
REFER TO SINGLE LINE FOR CONDUIT AND 2.
LOCATIONS OF EXISTING UTILITIES ARE ESTIMATED.
AUTHORITIES TO AVOID ANY EXISTING UTILITIES.
UNDERGROUND WORK WITH THE APPROPRIATE
SHALL COORDINATE AND CONFIRM ALL ALL
VOLTAGE CABLES IN WORK AREA. CONTRACTOR
THERE ARE UNDERGROUND WATER LINES AND LOW 1.
C.
EACH SIDE.
BUILDING AND THREE SIGNS EQUALLY SPACED ON
SIGN DETAIL #15. PLACE ONE SIGN ON EACH END OF
LIMITED TO ONLY (2) PERSONS AT A TIME", SEE E-625,
WALLS OF BUILDINGS TO INDICATE "ROOF ACCESS IS
CONTRACTOR SHALL PLACE SIGNAGE ON EXTERIOR B.
USED IN THE BUILDING ROOF DESIGN.
MATERIAL STACKING TO BE LESS THAN THE LIVE LOAD
CONTRACTOR SHALL LIMIT PERSONNEL, EQUIPMENT, & A.
SHADE STRUCTURE IS 10 METER HEIGHT.E.
STRUCTURE PER STRUCTURAL NOTE 2 ON DWG. G-002.
THE PV PANEL SUPPORTING SYSTEM TO THE EXISTING
SYSTEM PER THE PANELS' MANUFACTURER. INSTALL
INSTALL SOLAR PANELS TO PV PANEL SUPPORTING D.
INSTALLATION.
FOR ANY DAMAGES ON THE ROOF DURING
DAMAGES. THE CONTRACTOR IS FULLY RESPONSIBLE
THE UNSUPPORTED ROOF DECKS TO PREVENT ROOF
ONLY ON THE PURLINS. AVOID STEPPING DIRECTLY ON
WHEN WORKING ON THE ROOF, WALKING IS ALLOWED
PLAN NOTES
SHEET SYMBOLS
AIRBORNE ROAD
FENCE
EXISTING
GENERATORS
DC SOLAR CABLES
AC POWER CABLES
AC INVERTER CABLES
IN CONCRETE
PVC SCH. 80 ENCASED
RVTT
T6064
T6063
B54
FENCE
EXISTING GATE
EXISTING
PROPOSED CARPORT - 3
BUNKER
EXISTING
ARRAY 3
ARRAY 2
G12
Gx
G18
G17
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
E-108
E L
E C
T R
IC
A
L S
IT
E
P L
A N
:3
NORTH
PLAN
SCALE: 1 : 200
2 201010A1
SCALE: 1:200
ELECTRICAL SITE PLAN - 6
GENERAL NOTES
LOCATION. 7.
MANUFACTURER'S INSTALLATION MANUAL.
SOLAR INVERTERS TO BE INSTALLED PE 6.
WILL BE TYPE USE-2.
NOT IN CONDUIT AND ARE EXPOSED TO SUNLIGHT
LOCATIONS FOR WIRES IN CONDUIT. CONDUCTORS
C, 600V INSULATION SUITABLE FOR WET & DRY
WIRING SHALL BE THWN-2, RATED FOR 90 DEGREES 5.
INSTALLED ON CONCRETE PADS.
EXTERIOR ELECTRICAL EQUIPMENT SHALL BE 4.
NEMA 4 OR HAVE AN IP 65 RATING.
ELECTRICAL ENCLOSURE CABINETS SHALL BE RATED 3.
CONDUCTOR SIZES.
REFER TO SINGLE LINE FOR CONDUIT AND 2.
LOCATIONS OF EXISTING UTILITIES ARE ESTIMATED.
AUTHORITIES TO AVOID ANY EXISTING UTILITIES.
UNDERGROUND WORK WITH THE APPROPRIATE
SHALL COORDINATE AND CONFIRM ALL ALL
VOLTAGE CABLES IN WORK AREA. CONTRACTOR
THERE ARE UNDERGROUND WATER LINES AND LOW 1.
MAYBE PARTY OF THE PERIMETER SEPARATION.
STRUCTURE. AN ADJACENT FACILITY EXTERIOR WALL
PROVIDED NOT LESS THAN 100 FEET FROM THE
THE INSTALLATION'S FACILITY STANDARDS MUST BE
PERIMETER FENCE OR WALL IN ACCORDANCE WITH
OR AN IDENTIFIED OUTDOOR USE AREA. A
THAN 100 FEET (30 M) TO AN OCCUPIED STRUCTURE
LITHIUM BATTERY MUST BE LOCATED NO CLOSER
UNOCCUPIED STRUCTURES HOUSING
WHEN WORKING ON THE ROOFC.
SIDE.
CARPORT AND THREE SIGNS EQUALLY SPACED ON EACH
SIGN DETAIL #15. PLACE ONE SIGN ON EACH END OF
LIMITED TO ONLY (2) PERSONS AT A TIME", SEE E-625,
WALLS OF BUILDINGS TO INDICATE "ROOF ACCESS IS
CONTRACTOR SHALL PLACE SIGNAGE ON EXTERIOR B.
USED IN THE BUILDING ROOF DESIGN.
MATERIAL STACKING TO BE LESS THAN THE LIVE LOAD
CONTRACTOR SHALL LIMIT PERSONNEL, EQUIPMENT, & A.
STRUCTURE PER STRUCTURAL NOTE 2 ON DWG. G-002.
PV PANEL SUPPORTING SYSTEM TO THE EXISTING
SYSTEM PER THE PANELS' MANUFACTURER. INSTALL THE
INSTALL SOLAR PANELS TO PV PANEL SUPPORTING D.
ROOF DURING INSTALLATION.
FULLY RESPONSIBLE FOR ANY DAMAGES ON THE
PREVENT ROOF DAMAGES. THE CONTRACTOR IS
DIRECTLY ON THE UNSUPPORTED ROOF DECKS TO
ALLOWED ONLY ON THE PURLINS. AVOID STEPPING
, WALKING IS
PLAN NOTES
SHEET SYMBOLS
TT-618
PROPOSED BESS
TT-617 TT-616
GATE
EXISTING
FENCE
EXISTING
GATE
EXISTING
MSB
PROPOSED
SWITCHBOARD
AC COMBINER
PROPOSED
TRANSFORMER
PROPOSED
GEN
EXISTING
GENERATOR
EXISTING
CABLES
PROPOSED MV
GENERATOR
PROPOSED
GENERATORS
DC SOLAR CABLES
AC POWER CABLES
AC INVERTER CABLES
IN CONCRETE
PVC SCH. 80 ENCASED
CARPORT - 1
PROPOSED
LAYDOWN AREA
CONTRACTOR
G4
G3
Gx
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
E-109
IN
V
E R
T E
R E
Q U
IP
M
E N
T L
A Y
O U
T
T Y
P
IC
A L
S O
L
:3
A11 ON SHEET E-501.
GROUNDED. REFERENCE FENCE GROUNDING DETAIL
SHEET. ENSURE FENCE AND GATES ARE BONDED AND
ELECTRICAL CONCRETE PADS AS SHOWN ON THIS
INSTALL CHAIN LINK FENCE AND GATES AROUND 8.
APPROXIMATE.
EQUIPMENT INSTALLED. DIMENSIONS SHOWN ARE
PADS SHALL BE SIZED TO ACCOMODATE ACTUAL
SHALL BE INSTALLED ON CONCRETE PADS. CONCRETE
ELECTRICAL EQUIPMENT PLACED AT GROUND LEVEL 7.
ALL USE-2 STRING WIRING TO BE OPEN FREE AIR.6.
BE TYPE USE-2.
NOT IN CONDUIT AND ARE EXPOSED TO SUNLIGHT WILL
LOCATIONS FOR WIRES IN CONDUIT. CONDUCTORS
600V INSULATION SUITABLE FOR WET & DRY
WIRING SHALL BE THWN-2, RATED FOR 90 DEGREES C, 5.
NEMA 4 OR HAVE AN IP 65 RATING.
ELECTRICAL ENCLOSURE CABINETS SHALL BE RATED 4.
CONDUCTOR SIZES.
REFER TO SINGLE LINE DIAGRAMS FOR CONDUIT AND 3.
INDICATED AS EXISTING.
ALL EQUIPMENT ON THIS SHEET IS NEW UNLESS 2.
AUTHORITIES TO AVOID ANY EXISTING UTILITIES.
UNDERGROUND WORK WITH THE APPROPRIATE
SHALL COORDINATE AND CONFIRM ALL
VOLTAGE CABLES IN WORK AREA. CONTRACTOR
THERE ARE UNDERGROUND WATER LINES AND LOW 1.
GENERAL NOTES
(INV-1)
INVERTERDISCONNECT
RECOMBINER
MASTER
SEE J1/S-502
CONCRETE PAD
EQUIPMENT
+/-1M
FENCE, SEE NOTE 8.
NEW CHAIN-LINK
A1/C-501
GATE, SEE DETAIL
PEDESTRIAN
REF. E-101
BUILDING
CONDUITS FROM
+/-8M
M
FROM BUILDING
DOWN CONDUITS
A1
SCALE: N.T.S.
TYPICAL SOLAR INVERTER EQUIPMENT LAYOUT
FENCE, SEE NOTE 8 & 9.
NEW CHAIN-LINK
SHEET SYMBOLS
DC SOLAR CABLES
AC POWER CABLES
AC INVERTER CABLES
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
E-110
E Q
U
IP
M E
N T
L A
Y O
U T
A C
C O
M B
IN
E
R S
W
IT
C H
B O
A R
D
:3
T8.
7.
FENCE.
NEW FENCE SHALL MATCH HEIGHT AND TYPE AS EXISTING
REFERENCE FENCE GROUNDING DETAIL A11 ON SHEET E-501.
ENSURE FENCE AND GATES ARE BONDED AND GROUNDED.
ELECTRICAL CONCRETE PADS AS SHOWN ON THIS SHEET.
PEDESTRIAN ACCESS GATE, AND DOUBLE GATE AROUND
ADJACENT TO THE POWER PLANT. INSTALL CHAIN LINK FENCE,
ADD NEW FENCE TO ENCLOSE THE MICROGRID EQUIPMENT 6.
DIMENSIONS SHOWN ARE APPROXIMATE.
BE SIZED TO ACCOMODATE ACTUAL EQUIPMENT INSTALLED.
BE INSTALLED ON CONCRETE PADS. CONCRETE PADS SHALL
ELECTRICAL EQUIPMENT PLACED AT GROUND LEVEL SHALL 5.
OR HAVE AN EQUIVALENT IP RATING.
ELECTRIAL ENCLOSURE CABINETS SHALL BE RATED NEMA 4 4.
CONDUCTOR SIZES.
REFER TO SINGLE LINE DIAGRAMS FOR CONDUIT AND 3.
AS EXISTING.
ALL EQUIPMENT ON THIS SHEET IS NEW UNLESS INDICATED 2.
UTILITIES.
APPROPRIATE AUTHORITIES TO AVOID ANY EXISTING
ALL UNDERGROUND AND CONFIRM ALL WORK WITH THE
CABLES IN WORK AREA. CONTRACTOR SHALL COORDINATE
THERE ARE UNDERGROUND WATER LINES AND LOW VOLTAGE 1.
PERIMETER SEPARATION.
AN ADJACENT FACILITY EXTERIOR WALL MAYBE PARTY OF THE
PROVIDED NOT LESS THAN 100 FEET FROM THE STRUCTURE.
WITH THE INSTALLATION'S FACILITY STANDARDS MUST BE
USE AREA. A PERIMETER FENCE OR WALL IN ACCORDANCE
M) TO AN OCCUPIED STRUCTURE OR AN IDENTIFIED OUTDOOR
BATTERY MUST BE LOCATED NO CLOSER THAN 100 FEET (30
LOCATION. UNOCCUPIED STRUCTURES HOUSING LITHIUM 9.
REQUIREMENTS.
AND STRUCTURAL NOTES ON DWG. G-002 FOR
SWITCHBOARD AND BESS EQUIPMENT. SEE SPECIFICATIONS
COMPLETE CANOPY STRUCTURE FOR THE AC COMBINER
CONTRACTOR MUST DESIGN AND CONSTRUCT A HE
INSTALLATION MANUAL.
BESS SYSTEM TO BE INSTALLED PER MANUFACTURER'S
GENERAL NOTES
A1
SCALE: N.T.S.
AC COMBINER SWITCHBOARD EQUIP LAYOUT
STORAGE SYSTEM (BESS)
1500KW/1500KWh BATTERY ENERGY
PROPOSED
S W
IT
C
H B
O A
R D
A C
C O
M B
IN
E
R
P R
O P
O S
E D
FENCE. SEE NOTE 6.
NEW CHAIN-LINK
FENCE. SEE NOTE 6.
NEW CHAIN-LINK
SEE DETAIL J1/C-501
DOUBLE-GATE,
NEW
+/-1M
M
+/-10M
M
+/-14M
M
NOTE 6.
FENCE. SEE
NEW CHAIN-LINK
CABLES
AC POWER
REF, E-101
SOLAR INVERTERS
CABLES FROM
AC INVERTER
+/-1M
COMM WIRE
M
TRANSFORMER
PROPOSED
GENERATOR
PROPOSED 1.5MW
MSB
PROPOSED
SHEET SYMBOLS
DC SOLAR CABLES
AC POWER CABLES
AC INVERTER CABLES
FENCE, SEE NOTE 9.
NEW CHAIN-LINK
FENCE. SEE NOTE 6.
NEW CHAIN-LINK
FENCE. SEE NOTE 6.
NEW CHAIN-LINK
+/-1M
M
+/-14M
M
NOTE 6.
FENCE. SEE
NEW CHAIN-LINK
+/-1M
M
NOTE 9.
FENCE, SEE
NEW CHAIN-LINK
SEE DETAIL J1/C-501
DOUBLE-GATE,
NEW
A1/C-501
GATE, SEE DETAIL
PEDESTRIAN
A1/C-501
GATE, SEE DETAIL
PEDESTRIAN
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
E-501
P V
S Y
S T
E M
D E
T A
IL
S
N .T
.S
LOCK NUT
WASHER
SS TOOTHED
WIRE BONDING LUG
WASHER
GROUND BOLT
FRAME
PV ALUMINUM
FINISHED GRADE
GK CONNECTOR
BURNDY TYPE
AND TAMPING
BY ADDING WATER
OF ROD, COMPACT
WITHIN 152mm OF TOP
FILL WITH SOIL TO
CABLE
GROUND LOOP
BARE COPPER
MIN SIZE 120mm2
ROD
COPPER GROUND
20mm x 3M
AS REQUIRED
1-PIECE COVER
BOX WITH
CONCRETE METER
3"
BAND.
CONNECTION OF COPPER
DRILL AND TAP GATE FOR BURNDY TYPE B
25mm WID BY 305mm LONG
FLEXIBLE COPPER BRAID
ACCEPT (TYP)
SIZE BOLT LUG WILL
CONNECTION. USE MAXIMUM
COMPRESSION LUG
DRILL AND TAP POST FOR
CADWELD CONNECTION
CONDUCTOR SIZE 16mm2
BARE COPPER GROUND
LEADS ARE FUSED AND SWITCHED.
1. SCHEMATIC REPRESENTS A POSITIVE ARRAY. POSITIVE
200A
NEGATIVE
RCBN-1
POSITIVE
RCBP-1
CB-1A1
CB-1A2
CB-1A3
CB-1A4
CB-1A5
CB-1A6
CB-1B1
CB-1B2
CB-1B3
CB-1B4
CB-1B5
CB-1B6
NEGATIVE
RCBN-2
POSITIVE
RCBP-2
GND + -
GND - +
WITH (2) 800A FUSES
DC DISCONNECT SWITCH
1200A, 2-POLE 600V
INVERTER
TO
GND - +
GND + -
RECOMBINER
MASTER
FROM
WITH (2) 800A FUSES
DC DISCONNECT SWITCH
1200A, 2-POLE 600V
INVERTER
TO
GROUND WIRE
BARE COPPER
TRENCH WIDTH TO VARY
CONDUIT COUNT AND
WITH NATIVE SOIL
BACK FILL TRENCH
CONDUIT
305mm ABOVE
WARNING
RED TAPE
SPACING
38mm
76mm
VARIES
1M
+ RED USE-2
- WHITE USE-2
15A
COMBINER MASTER COMBINER
COMBINER
MASTER COMBINER
15A
INVERTER
CB-2A1
CB-2A2
CB-2A3
CB-2A4
CB-2A5
CB-2A6
CB-2B1
CB-2B2
CB-2B3
CB-2B4
CB-2B5
CB-2B6
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
200A
RECOMBINER
MASTER
FROM
(2) 0.24" GROUND HOLES
m m
2024mm
E1
SCALE: N.T.S
DC DISCONNECT WIRING DIAGRAM
POSITIVE ARRAY
E6
SCALE: N.T.S
DC DISCONNECT WIRING DIAGRAM
NEGATIVE ARRAY
L1
SCALE: N.T.S
MASTER COMBINER FUSING
L7
SCALE: N.T.S
MODULE GROUNDING LOCATION
E11
SCALE: N.T.S.
WIRING DIAGRAM
A1
SCALE: N.T.S
MODULE GROUND LUG
A6
SCALE: N.T.S
GROUND WELL DETAIL
A16
SCALE: N.T.S
TRENCH DETAIL (TYPICAL)
A11
SCALE: N.T.S
FENCE GROUNDING DETAIL
LEADS ARE FUSED AND SWITCHED.
1. SCHEMATIC REPRESENTS A NEGATIVE ARRAY. NEGATIVE
NOTE:NOTE:
AND EVERY OTHER FENCE POST.
1. GROUND EACH CORNER POST, GATE SUPPORT POST,
NOTE:
DESIGNATION OF POSITIVE AND NEGATIVE STRINGS.
1. REFER TO COMBINER SCHEDULE, E-605, FOR
NOTE:
+ RED USE-2
- WHITE USE-2
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
E-601
O N
E -L
IN
E
D
IA
G R
A M
E L
E C
T R
IC
A
L
N .T
.S
A1
SCALE: N.T.S.
ELECTRICAL ONE-LINE DIAGRAM
100% RATED
3P, GFP
2000AT
2500AF
PROPOSED MSB 415/240V, 6000A, 3PH, 4W, 100 kAIC
GFP
3P
4000AT
4000AF
1.5 MW GENERATOR
PROPOSED
3P
300 AT
300 AF
GFP
3P
4000AT
4000AF
PROPOSED AC COMBINER SWITCHBOARD 415/240V, 4W, 4000A, 3PH, 100kAIC
3P
200 AT
200 AF
3P
300 AT
300 AF
3P
150 AT
200 AF
3P
150 AT
200 AF
3P
200 AT
200 AF
RATED
100%
3P, GRP
2500 AT
2500 AF
INVERTER
1500KW
LITHIUM-ION
BATTERY STORAGE
& 185mm2 GND)
7 SETS OF (4-240mm2
& 16mm2 GND
4/C-95mm2
4/C-50mm2
& 25mm2 GND
4/C-150mm2
(4- 400mm2 + 240mm2 GND)
8 SETS OF
DIRECT BURIAL
& 35mm2 GND
3-300mm2 (MV 105) BOX (SB)
SECTIONALIZING
EXISTING
SECONDARY SIDE.
FAULT AMPS AT
42k AVAILABLE
TRANSFORMER
5% IMPEDANCE
11kV-415/240V, PROPOSED 1500kVA
95mm2 GEC
& 150mm2 GND)
6 SETS OF (4-300mm2
NEMA 4 450 KVA 50HZ TO 60 HZ FREQUENCY CONVERTER. 5.
SWITCHBOARD.
TO CIRCUIT BREAKER AT THE END OF THE BUS OF THE MSB
LOADSIDE CONNECTION: CONTRACTOR TO INTERCONNECT 4.
SIDE INTERCONNECTION.
NATIONAL ELECTRIC CODE (NEC), SECTION 705.12, LOAD
COMPLY WITH ALL RELEVANT SECTIONS OF THE 2020
NEW SWITCHGEAR, SWITCHBOARD, AND INVERTERS SHALL 3.
RATED NEMA 4.
ALL NEW EXTERIOR ELECTRICAL ENCLOSURES SHALL BE 2.
EQUIPMENT.
PT'S, CT'S AND OTHER REQUIRED SYSTEM CONTROLS
CONTRACTOR SHALL PROVIDE ALL NEW METERS, RELAYS, 1.
NOTES
SHALL BE RATED NEMA 4.
ALL NEW EXTERIOR ELECTRICAL ENCLOSURES 10.
DEMAND LOADS OVER PV AND BESS CAPACITY.
GENERATOR WHEN ISLANDING MODE ACTIVATED AND
CIRCUIT BREAKER CONTROL SHALL ENERGIZE THE 9.
MEANS.
BESS ISLANDING CONTROLLER OR BE OTHER CONTROL
ISLANDING MODE INITIATED. TO BE CONTROLLED BY
UPSTREAM MAIN CIRCUIT BREAKERS OPEN WHEN
BREAKERS. CIRCUIT BREAKERS TO CLOSE WHEN
SYNCHING CAPABLE AND CONTROLLED CIRCUIT 8.
CONTROLLED BY ISLANDING CONTROLLER.
CONTROL BREAKER (GRID DISCONNECT) TO BE 7.
AND AC SIDE OF THE INVERTER(S).
APPLY SPDs (SURGE PROTECTION DEVICE) ON THE DC 6.
POI SEE NOTE 4
3P
200A
3P
(N)
MTS
100A
G17
(E)
MTS
200A
(N)
MTS
100A
G15
(N)
MTS
100A
G14
(N)
MTS
100A
G13
(N)
MTS
800A
G12
(N)
MTS
100A
G11
(N)
MTS
800A
G10
(N)
MTS
100A
G8
(N)
MTS
100A
G9
(N)
MTS
400A
G7
(N)
MTS
800A
G6
(N)
MTS
200A
G5
(N)
MTS
200A
G4
(N)
MTS
200A
G3
(N)
MTS
200A
G2
(E)
MTS
400A
G1A & G1B
(N)
MTS
100A
G18
3P
3P
3P
3P
3P
3P
3P
3P
3P
3P
3P
3P
3P
3P
3P
3P
3P
(SEE NOTE 5)
CONVERTER
FREQ.
LOADS FEEDRE SCHEDULE
INVERTER
150KW
INVERTER
75KW
INVERTER
150KW
INVERTER
75KW
INVERTER
75KW
INVERTER
100KW
RATED
100%
RATED
100%
NEEDED.
CHARGED AT NIGHT BY CAMP POWER IF
SYSTEM DURING THE DAY. BESS COULD BE
BESS SHALL BE CHARGED BY THE PV SOLAR d.
LOAD HOURS AND/OR AS NEEDED.
SHAVING AND DISCHARGE DURING PEAK
THE BESS SHALL UTILIZED FOR PEAK c.
LOAD DURING DAYLIGHT HOURS.
THE PV SOLAR SYSTEM SHALL SUPPORT THE b.
POWER SOURCE
CAMP'S POWER SHALL BE THE PRIMARY a.
POWER.
<=80% OF MICRO-GRID'S GENERATING
GENERATOR TO SHUT DOWN IF THE LOAD IS f.
MODE.
SHALL ENERGIZED DURING ISLANDING
THE GENERATOR AND THE MICROGRID e.
SYSTEM OPERATION
240M<L
169M<L
201M<L
203M<L
403M<L
285M<L
20M<L
RVTT BUILDING B606 BUILDING B610 BUILDING B608 BUILDING B611CARPORT - 1
L
M
V D
.8
G16A & G16B
L
M
V D
.9
L
M
V D
.1
L
M
V D
.2
L
M
V D
.9
L
M
V D
.5
L
M
V D
.1
L
M
V D
.6
L
M
V D
.2
L
M
V D
.4
L
M
V D
.2
L
M
V D
.8
L
M
V D
.5
L
M
V D
.7
L
M
V D
.1
L
M
V D
.5
L
M
V D
.3
L
M
V D
.2
RATED
3P, 100%
2000AT
2500AF
4-300mm2+35mm2 GND IN 1-103 C
4-95mm2+16mm2 GND
4-50mm2+16mm2 GND
2 SET (4-185mm2+70mm2 GND)
4-150mm2+25mm2 GND
4-35mm2+10mm2 GND
4-70mm2+25mm2 GND
GFPE
GFPE
95mm2 GEC
CONDUCTOR
GROUNDING
SUPPLY SIDE
8 AND 9
SEE NOTE
DIRECT BURIAL
DIRECT BURIAL
DIRECT BURIAL
DIRECT BURIALDIRECT BURIALDIRECT BURIALDIRECT BURIAL
DIRECT BURIALDIRECT BURIAL
& 25mm2 GND
4/C-150mm2
DIRECT BURIAL
& 25mm2 GND
DIRECT BURIAL
& 25mm2 GND
INVERTER
100KW
CARPORT - 2 & 3
DIRECT BURIALDIRECT BURIAL
3P
150 AT
200 AF
111M<L
8 4-120mm2+35mm2 GND
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
_P la ns -0
M P
B U
E H
R
IN
G
K U
W A
IT
E R
C
IP
F Y
Z O
N E
S O
L A
R P
V a n d
.5
M W
/1 .5
M W
H R
B E
S S
I N
S T
A L
L A
T
IO
N
M
IC
R O
G R
ID
P
R O
J E
C T
K
W
B R
IA
N
R
J O
H N
S O
N
P .E
T .L
.C
M O
H A
M M
E D
M A
A R
O O
F
P .E
B .R
.J
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
P R
O J E
C T
N O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
F
IL
E N
U M
B…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .