Ramey Army Reserve Center (ARC) Microgrid Construction-Aguadilla, Puerto Rico
Solicitation number
W912QR24R0044
Issued by

About this file

This document appears to be a set of technical drawings for the Ramey Army Reserve Center (ARC) Microgrid Construction project in Aguadilla, Puerto Rico. The drawings include plans for the Energy Control Center, raceway details, conduit section views, and a partial single line electrical diagram. The drawings are part of Solicitation W912QR24R0044 issued by the U.S. Army Corps of Engineers Louisville District for the construction of the Ramey ARC Microgrid. The solicitation is a full and open procurement with an estimated price range between $10,000,000 and $25,000,000. The North American Industrial Classification System (NAICS) code is 237130 - Power and Communication Line and Related Structures Construction, with a size limitation of $45,000,000. The project requires HUBZone 10% price evaluation preference. Offerors must register and complete the representation and certification requirements in the System for Award Management (SAM) database.

View the file

Other files

File Type Posted
W912QR24R0044_Plans-0003.pdf PDF
W912QR24R0044-0003.pdf PDF
W912QR24R0044 0002.pdf PDF
W912QR24R0044_Plans-0002.pdf PDF
W912QR24R0044_Specs-0002.pdf PDF
Site Visit.pdf PDF
W912QR24R0044 0001.pdf PDF
W912QR24R0044_Specs-0001.pdf PDF
W912QR24R0044_Plans-0000.pdf PDF
W912QR24R0044_Specs_Vol1-0000.pdf PDF
W912QR24R0044_Specs_Vol2-0000.pdf PDF
W912QR24R0044 PCO Approved.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers Louisville District

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

-W Q

R D

W D

Y F

N

O V

B D

O M

B R

O W

S K

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

P R

A R

E R

C

IP

M

IC

R O

G R

ID

S

P R

O J E

C T

N U

M B

E R

P

R A

M E

Y A

R M

Y R

E S

E R

V E

C E

N T

E R

A

G U

A D

IL

L

A

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

RTA SUBMISSION

C .M

A N

IS

C M

A N

IS

H W

R

IG

H T

E-200

-E

-2

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

CERTIFIED FINAL

1.

.5

36.0

Energy Control Center

ECCSTATUS AUTO MANUAL

SECT 1 SECT 3 SECT 4 SECT 5 SECT 6

:DENOTES SEALING SCREWS

NO T-BUS

T-BUS

195 IN

T-BUS

270 IN

T-BUS

195 IN

T-BUS

270 IN

BESS-R-01

175 AT

BESS-R-02

175 AT

BESS-R-03

175 AT

DG-01

600 AT

SECT 2

T-BUS

195 IN

30.0 36.0

XFMR-R-01

225 AT

XFMR-R-02

225 AT

XFMR-R-03

125 AT

XFMR-R-04

70 AT SPD 240KA

30.0 30.0

XFMR-R-UTIL

1200 AT

PV-DISC

600 AT

36.0

SPARE

250AF

SPARE

250AF

NOTE: ALL DEVICES REQURING DRILLING OR INSERTION IN MOUNTING PAD

SUCH AS CONDUIT, ANCHORING STUDS, SLEEVE INSERTS, ECT.

SHOULD BE INSTALLED BEFORE SETTING EQUIPMENT IN PLACE

NOTE:

A MINIMUM IF 2.00/[51]

CLEARANCE BEHIND THE

SWITCHBOARD IS REQUIRED

FOR TOP COVER OVERHANG

.75/[19] DIA

MTG HOLES OFFSET

3.00/[76] TYP

FOR SIDE

2' - 9"

3' - 11 1/2"

1' - 0 1/2"

10' - 2"

24' - 0"

45 KVA XFMR

XFMR-R-04

1' - 8"

1' - 7"

30.0 30.0 36.0 36.0 30.0 36.0 1' - 8"

6"

225A PANEL

PP-R-01

FRONT

3 33

3' - 6"

GENERAL NOTES

A REFER TO SHEET E-001 FOR SYMBOLS AND GENERAL

NOTES AND E-002 FOR ABBREVIATIONS.

B REFER TO MECHANICAL AND STRUCTURAL SITE PLANS

FOR SWITCHBOARD, PAD MOUNTED TRANSFORMER AND

MCC LOCATIONS.

C ARRANGEMENT OF SECTION-1, MAIN AND SECTION-6,

MAIN GENERATOR IN THE NEW METAL CLAD

SWITCHBOARD.

D 3.5 FEET WORKING SPACE IN FRONT OF ELECTRICAL

EQUIPMENT WITH LIVE PARTS AT 480V PER NEC 2020

TABLE 110.26(A)(1).

KEYNOTES

1 CONCRETE BLOCK STRUCTURE ENCLOSURE FOR ECC.

REFERENCE STRUCTURAL FOR ADDITIONAL INFORMATION.

2 PROVIDE WALL MOUNTED HVAC SYSTEM WITH CLIMATE

CONTROLS

3 FINAL DIMENSIONS AND CUT OUTS TO BE COORDINATED BY

CONTRACTOR BASED ON SELECTED ENERGY CONTROL

CENTER EQUIPMENT.

SCALE 3/4" = 1'-0"E1 ECC ELEVATION FRONT

SCALE 3/4" = 1'-0"A1 ECC FLOOR PLAN

/2

3/

E C

C S

W

IT

C H

BO

AR

D P

L A

N A

N D

E L E

V A

T

IO

N

R

EV

IS

ED

IN

A

C C

O R

D

AN

C E

W

IT

H A

M

EN

D M

EN

T

0 0

W

2Q R

R

_P la ns -0

ARIMS: 200A Disposition: Maintain for 15 yrs after construction.

Louisville District

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

-W Q

R D

W D

Y F

N

O V

B D

O M

B R

O W

S K

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

P R

A R

E R

C

IP

M

IC

R O

G R

ID

S

P R

O J E

C T

N U

M B

E R

P

R A

M E

Y A

R M

Y R

E S

E R

V E

C E

N T

E R

A

G U

A D

IL

L

A

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

RTA SUBMISSION

C .M

A N

IS

C M

A N

IS

H W

R

IG

H T

E-504

T Y

P

IC

A L R

A C

E W

A Y

D E

T A

IL

S

-E

-5

GENERAL NOTES

A RGS COUPLING SHALL BE PROVIDED FOR EACH RGS DUCT

TERMINATION. RGS NIPPLES AND INSULATIONS GROUNDING

BUSHINGS SHALL BE INSTALLED (PRIOR TO CABLE

INSTALLATION) ON ALL EXPOSED RIGID STEEL DUCT

COUPLING.

B WHEN HORIZONTAL, RACEWAY IS RGS. A STANDARD RGS

COUPLING ( OR AN ERICKSON COUPLING) SHALL BE USED

FOR CONNECTION TO RGS RISER ELBOW.

C RACEWAY SHALL BE PLUGGED UNTIL USED.

D EMBEDDED CONDUIT RISER ELBOWS SHALL HAVE A MINIMUM

CENTERLINE RADIUS EQUAL TO 6 TIMES THE NORMAL

DIAMETER OF THE CONDUIT.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

CERTIFIED FINAL

TOP OF FINISHED

CONCRETE SLAB

RGS COUPLING

PVC COUPLING

RIGID GALVANIZED

STEEL ELBOW

THREADED RGS COUPLING

WITH PLUG

PVC COATED

RGS RISER

TOP OF

FINISHED

CONCRETE

SLAB

THREADED COUPLING WITH PLUG

PVC COATED RGS EXTENSION AS REQ'D

PVC COATED RGS COUPLING

(PROVIDED WITH ELBOW)

PVC COUPLING

(PROVIDED WITH ELBOW)

3" UNREINFORCED CONCRETE

PVC COATED RGS

ELBOW AS REQ'D

SLOPE CONCRETE AWAY

FROM CONDUIT

FINISHED GRADE

CHAMFER

ALL SIDES

3" UNREINFORCED CONCRETE MIX

CLASS A1 PER SPECIFICATION

6" U

N O

THREADED COUPLING WITH PLUG

RIGID GALVANIZED

STEEL ELBOW AS REQ'D

PVC COATED RGS EXTENSION AS REQ'D

PVC COATED RGS COUPLING

(PROVIDED WITH ELBOW)

PVC COUPLING

(PROVIDED WITH ELBOW)

5'-0"

GENERATOR PAD

1/2" BOND BREAK

PVC COATED RGS RISER

PVC S40

PVC COATED RGS ELBOW

PVC S40

1"

BOND

BREAK

2" OR LESSFLEX CONNECTOR

GREATER THAN 2"

PVC

COUPLING

BASE SIZE AND LOCATION AS

INDICATED ON S5000 SERIES DRAWINGS

THREADED RGS COUPLING WITH PLUG

SEE PLAN DWG FOR LOCATION

CHAMFER ALL SIDES

TOP OF FINISHED

CONCRETE SLAB

ELECTRICAL

EQUIPMENT

OR PULLBOX

BASE SIZE AND LOCATION AS

INDICATED ON S5000 SERIES

DRAWINGS

PVC COATED RGS

EXTENSION

AS REQ'D

COUPLING

COUPLING

RIGID GALVANIZED

STEEL ELBOW

SPARE INNERDUCTS

FIBER CABLE

EXTERNAL CONDUIT

SINGLE 3 CELL INNERDUCT

CONCRETE WALL ASSEMBLY

PIPE OR CONDUIT

REFER TO CIVIL, ELECTRICAL,

AND MECHANICAL FOR

PENETRATION LOCATIONS

MIN. 1 1/4" SEALANT APPLIED

WITHIN ANNULUS, FLUSH WITH

BOTH SURFACES OF WALL

MINERAL WOOL INSULATION

FIRMLY PACKED INTO OPENING

AS REQUIRED TO

ACCOMODATE FILL MATERIAL

ELASTOMERIC

FLASHING MEMBRANE

SCALE N.T.S.C1

TYPICAL EMBEDDED RACEWAY RISER

TERMINATING IN FOUNDATION

SCALE N.T.S.E4

TYPICAL UNDERGROUND RACEWAY

RISER TERMINATING IN CONCRETE SLAB

SCALE N.T.S.E1

TYPICAL UNDERGROUND RACEWAY

RISER TERMINATING IN SOIL

GENERAL NOTES

A RGS COUPLING SHALL BE PROVIDED FOR EACH RGS DUC

TERMINATION. RGS NIPPLES AND INSULATIONS GROUND

BUSHINGS SHALL BE INSTALLED (PRIOR TO CABLE

INSTALLATION) ON ALL EXPOSED RIGID STEEL DUCT

COUPLING.

B WHEN HORIZONTAL, RACEWAY IS RGS. A STANDARD RGS

COUPLING ( OR AN ERICKSON COUPLING) SHALL BE USE

FOR CONNECTION TO RGS RISER ELBOW.

C RACEWAY SHALL BE PLUGGED UNTIL USED.

D EMBEDDED CONDUIT RISER ELBOWS SHALL HAVE A MINI

CENTERLINE RADIUS EQUAL TO 6 TIMES THE NORMAL

DIAMETER OF THE CONDUIT.

SCALE N.T.S.A4 CONDUIT STUB UP TO GENERATOR PAD

SCALE N.T.S.C4

TYPICAL EMBEDDED RACEWAY RISER

TERMINATING IN FOUNDATION WITH EQUIPMENT BASE

SCALE 3" = 1'-0"A1 INNERDUCT DETAIL

SCALE 6" = 1'-0"A7 PENETRATION DETAIL

R

EV

IS

ED

IN

A

C C

O R

D

AN

C E

W

IT

H A

M

EN

D M

EN

T

0 0

/2 3/

W

2Q R

R

_P la ns -0

Louisville District

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

-W Q

R D

W D

Y F

N

O V

B D

O M

B R

O W

S K

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

P R

A R

E R

C

IP

M

IC

R O

G R

ID

S

P R

O J E

C T

N U

M B

E R

P

R A

M E

Y A

R M

Y R

E S

E R

V E

C E

N T

E R

A

G U

A D

IL

L

A

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

RTA SUBMISSION

C .M

A N

IS

C M

A N

IS

H W

R

IG

H T

E-505

C O

N D

U

IT

S E

C T

IO

N

V

IE

W S

-E

-5

GENERAL NOTES

A REFER TO SHEET E-001 FOR SYMBOLS AND GENERAL

NOTES, E-002 FOR ABBREVIATIONS AND E-003 FOR ONE

LINE SYMBOLS.

B REFER TO SHEET E-700 FOR CABLE AND CONDUIT

SCHEDULE.

C ALL CABLES SHALL HAVE A MINIMUM BENDING RADIUS AS

REQUIRED PER THE NEC AND UFC.

D REFER TO CALCULATION DOCUMENT FOR AMPACITY

CALCULATIONS.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

CERTIFIED FINAL

6" WIDE METALLIC

YELLOW

WARNING TAPE

A/C PAVEMENT

OR GROUND

LEVEL

COMPACTED

BACKFILL TO 90%

PVC SCHED 40

CONDUIT

4/0 BARE COPPER

CONDUCTOR

3000 PSI CONC.

ENCASEMENT

R-105

R-103F-001

R-104

C-004

C-004

SP

1' - 9"

REFER TO

SHEET

CU-200 FOR

DEPTH

SP SP

3"

3"

3"

3"

3"

3"

3"

1' - 9"

3" 3" 3" 3" 3" 3" 3"

R-112

SP

R-115

R-314

6" WIDE METALLIC

YELLOW

WARNING TAPE

A/C PAVEMENT

OR GROUND

LEVEL

COMPACTED

BACKFILL TO 90%

PVC SCHED 40

CONDUIT

4/0 BARE COPPER

CONDUCTOR

3000 PSI CONC.

ENCASEMENT

R-105

R-103

R-104

SP

2' - 3"

C-003

SP

REFER TO

SHEET

CU-200 FOR

DEPTH

R-316

SP

3"

3"

3"

3"

3"

3"

3"

1' - 8"

3" 3" 3" 3" 3" 3" 3" 3" 3"

6" WIDE METALLIC

YELLOW

WARNING TAPE

A/C PAVEMENT

OR GROUND

LEVEL

COMPACTED

BACKFILL TO 90%

PVC SCHED 40

CONDUIT

4/0 BARE COPPER

CONDUCTOR

3000 PSI CONC.

ENCASEMENT

R-201 R-202

SPARESPARE

3"

3"

3"

3"

3"

3"3"3"3"3"

REFER TO

SHEET

CU-200 FOR

DEPTH

1' - 4"

1' - 3"

6" WIDE METALLIC

YELLOW

WARNING TAPE

A/C PAVEMENT

OR GROUND

LEVEL

COMPACTED

BACKFILL TO 90%

PVC SCHED 40

CONDUIT

4/0 BARE COPPER

CONDUCTOR

3000 PSI CONC.

ENCASEMENT

R-201

R-202 R-116

R-116 C-001

R-109

R-107 R-311

R-114

2' - 7"

1' - 3"

3"

3"

3"

3"

3"

REFER TO

SHEET

CU-200 FOR

DEPTH

3"3"3"2"3"3"3"3"3"3"3"

SP

SCALE N.T.SD1 TO BESS AREA

SCALE N.T.SD3 TO BESS AND CANOPY 4

SCALE N.T.SA4 TO BLDG 808/807

SCALE N.T.SA1 TO POV SOUTH

R

EV

IS

ED

IN

A

C C

O R

D

AN

C E

W

IT

H A

M

EN

D M

EN

T

0 0

/2 3/

W

2Q R

R

_P la ns -0

6" WIDE METALLIC

YELLOW

WARNING TAPE

A/C PAVEMENT

OR GROUND

LEVEL

COMPACTED

BACKFILL TO 90%

4/0 BARE COPPER

CONDUCTOR

3000 PSI CONC.

ENCASEMENT

C-002 R-111 R-203

SPR-313SP 1' - 3"

REFER TO

SHEET CU-200

FOR DEPTH

1' - 8"

3"3"3"3"3"2"3"

3"

3"

3"

3"

3"

6" WIDE METALLIC

YELLOW

WARNING TAPE

A/C PAVEMENT

OR GROUND

LEVEL

COMPACTED

BACKFILL TO 90%

PVC SCHED 40

CONDUIT

4/0 BARE COPPER

CONDUCTOR

3000 PSI CONC.

ENCASEMENT

3"3"3"2"3"3"3"

3"

3"

3"

3"

3" R-311R-107 C-001

SPR-109 R-114

REFER TO

SHEET CU-200

FOR DEPTH

1' - 8"

1' - 3"

R-203

SPARE

6" WIDE METALLIC

YELLOW

WARNING TAPE

A/C PAVEMENT

OR GROUND

LEVEL

COMPACTED

BACKFILL TO 90%

PVC SCHED 40

CONDUIT

4/0 BARE COPPER

CONDUCTOR

3000 PSI CONC.

ENCASEMENT

3"2"3"

3"

2"

3"

2"

3"

REFER TO

SHEET CU-200

FOR DEPTH

1' - 1"

8"

US Army Corps of Engineers Louisville District

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

-W Q

R D

W D

Y F

N

O V

B D

O M

B R

O W

S K

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

P R

A R

E R

C

IP

M

IC

R O

G R

ID

S

P R

O J E

C T

N U

M B

E R

P

R A

M E

Y A

R M

Y R

E S

E R

V E

C E

N T

E R

A

G U

A D

IL

L

A

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

RTA SUBMISSION

C .M

A N

IS

C M

A N

IS

H W

R

IG

H T

E-506

C O

N D

U

IT

S E

C T

IO

N

V

IE

W S

-E

-5

SCALE N.T.SA1 TO BLDG 809 AND CANOPY 3

SCALE N.T.SD1 TO CANOPY 2

SCALE N.T.SD5 TO BLDG 809

GENERAL NOTES

A REFER TO SHEET E-001 FOR SYMBOLS AND GENERAL

NOTES AND E-002 FOR ABBREVIATIONS.

B FOR CONDUIT AND CABLE SCHEDULE, SEE SHEET

E-700.

C REFER TO SHEET E-100 FOR CONDUIT ROUTING.

D REFER TO CALCULATION DOCUMENT FOR AMPACITY

CALCULATIONS.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

CERTIFIED FINAL

R

EV

IS

ED

IN

A

C C

O R

D

AN

C E

W

IT

H A

M

EN

D M

EN

T

0 0

/2 3/

W

2Q R

R

_P la ns -0

Louisville District

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

-W Q

R D

W D

Y F

N

O V

B D

O M

B R

O W

S K

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

P R

A R

E R

C

IP

M

IC

R O

G R

ID

S

P R

O J E

C T

N U

M B

E R

P

R A

M E

Y A

R M

Y R

E S

E R

V E

C E

N T

E R

A

G U

A D

IL

L

A

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t

F o rt

W o rt h

T X

RTA SUBMISSION

C .M

A N

IS

C M

A N

IS

H W

R

IG

H T

E-601

P A

R T

IA

L S

IN

G

L E

L

IN

E D

IA

G

R A

M

N E

W W

O R

K

-E

-6

SCALE NTSA1 ONE-LINE DIAGRAM - NEW WORK

GENERAL NOTES

A REFER TO SHEET E-001 FOR SYMBOLS AND GENERAL

NOTES, E-002 FOR ABBREVIATIONS AND E-003 FOR ONE

LINE SYMBOLS.

B ALL CIRCUIT BREAKERS ARE 3 POLE UNLESS

OTHERWISE NOTED.

KEYNOTES

1 LUMA SERVICE CONNECTION TO BE UPGRADED AS

NECESSARY TO PROVIDE APPROPRIATE SYSTEM

PROTECTION AND DISCONNECT. ONGOING COORDINATION

WITH LUMA TO DETERMINE EXACT REQUIREMENTS.

2 MOLDED CASE CIRCUIT BREAKER (TYP.)

3 INTERCEPT EXISTING CONDUIT AT ATS. DISCONNECT AND

REMOVE EXISTING WIRING BACK TO NEAREST HAND HOLE.

EMPTY CONDUIT TO BE ABANDONED IN PLACE.

4 INTERCEPT EXISTING CONDUIT TO BUILDING. DISCONNECT

AND REMOVE EXISTING WIRING BACK TO EXISTING UTILITY

SERVICE LOCATION. EMPTY CONDUIT TO BE ABANDONED IN

PLACE.

5 REFER TO SHEETS E-610 A & B FOR CONTINUATION OF ONE

LINE

6 SEE SHEET E-603 FOR UPS SINGLE LINE DIAGRAM

7 CANOPY 4 INCLUDING LIGHTNING PROTECTION, LUMINARIES,

INVERTERS, AND PANELS ARE PART OF BID OPTION 1

8 EXTENSION OF CANOPY 4 INCLUDING LIGHTNING

PROTECTION, LUMINARIES, INVERTERS, AND PANELS ARE

PART OF BID OPTION 2

ONE-LINE DIAGRAM - NEW WORK

EMPTY CONDUIT TO BE ABANDONED IN PLACE.

4 INTERCEPT EXISTING CONDUIT TO BUILDING. DISCONNE

AND REMOVE EXISTING WIRING BACK TO EXISTING UTILI

SERVICE LOCATION. EMPTY CONDUIT TO BE ABANDONE

PLACE.

5 REFER TO SHEETS E-610 A & B FOR CONTINUATION OF O

LINE

6 SEE SHEET E-603 FOR UPS SINGLE LINE DIAGRAM

7 CANOPY 4 INCLUDING LIGHTNING PROTECTION, LUMINAR

INVERTERS, AND PANELS ARE PART OF BID OPTION 1

8 EXTENSION OF CANOPY 4 INCLUDING LIGHTNING

PROTECTION, LUMINARIES, INVERTERS, AND PANELS AR

PART OF BID OPTION 2

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

CERTIFIED FINAL

7.5 KVA

208-240V

MDP 809 ,208/120V, 400A

LP-K

208/120V 225A

LP-H

208/120V 225A

LP-D 1P

240/120V 60A

EMDPA, 208/120V, 400A

MDPA 807, 208/120V, 800A

LPK

208/120V 225A

ELPB-A

208/120V 125A

ELPC-A

208/120V 125A

LPA-A

208/120V 225A

LPB-A

208/120V 400A

LPC-A

208/120V 225A

ELPA-A

208/120V 125A

30 KVA

208-208V

CU-711

TRP-A

208/120V 225A

CU-712 CU-713 CU-721 CU-722 CU-731 CU-732

35 A 60 A 70 A 70 A 70 A 70 A 70 A 400 A

100 A 150 A 150 A 150 A 150 A 150 A 150 A

G

EMDPB, 208/120V, 400A

808 MDPB, 208/120V, 800A

ELPB-B

208/120V 125A

ELPC-B

208/120V 125A

LPA-B

208/120V 225A

LPB-B

208/120V 400A

LPC-B

208/120V 225A

ELPA-B

208/120V 125A

30 KVA

208-208V

CU-811

TRP-B

208/120V 225A

CU-812 CU-821 CU-822 CU-831 CU-832

60 A 70 A 70 A 60 A 70 A 40 A 400 A

100 A 150 A 150 A 150 A 150 A 150 A 150 A

250 A

50 A

100 A

LP-A 810

240/120V 125A

N

250 KW

E

NE

PULL

UP

GEN

BOX

800 A G N

250 KW

E

NE

PULL

UP

GEN

BOX

800 A

100 A100 A

G

ECC-R-01 480V 1200 A, 3 P + GND, 65KAIC

E.O.

DG-01

275 KW

XFMR-R-UTIL

750 KVA

4160-480V

E.O.

32R

BESS-

R-01

105 KW

1200 A

600 A 175 A E.O.

175 A 175 A

XFMR-R-02

150 KVA

480-208V

PP-R-01, 208/120V, 150A 10KAIC

E.O. E.O. E.O. E.O.

XFMR-R-03

75 KVA

480-208V500 A

250 A

XFMR-R-01

150 KVA

480-208V 500 A

E.O. E.O.

125 A 225 A 70 A225 A

XFMR-R-04

45 KVA

480-208V

125 A

FP-R-01

1/3 HP

DEF-

R-01/02

1/2 HP

600 A

BESS-

R-02

105 KW

BESS-

R-03

105 KW

ATS-02 ATS-01

M

M-101 R-101

M-102 R-102

M-103 R-103

M-104 R-104

M-105 R-105

M-106 R-106

M-202 R-202

M-203 R-203

M-201 R-201

M-204 R-204

M-301 R-301

M-303 R-303

M-302 R-302

M-304 R-304

AC-01 LTG-

RAMEY

AUX-R-01

M-308/309 R-308/309

M-306/307 R-306/307

M-305 R-305

M-310 R-310

M-311-316 R-311-316

UTILITY

PVPNL-R-01 480/277V

600A 50KAIC

80 A 80 A 80 A 80 A 100 A 80 A 80 A

M-107 M-108 M-109 M-110 M-111 M-112 M-113

M-205 R-205

PV-DISC 480/277V

600 A 65KAIC

MAIN-DISC 480/277V

1200A 65KAIC

M-100 R-100

PP-R-02

20 A

20 A 20 A 20 A 20 A 20 A

50 A

20 A

TO UPS

SPARE

250AF

SPARE

250AF

E.O. E.O. E.O. E.O. E.O. E.O. E.O.

7 8

ONE-LINE DIAGRAM - NEW WORK

REMOVE EXISTING WIRING BACK TO NEAREST HAND HO

EMPTY CONDUIT TO BE ABANDONED IN PLACE.

4 INTERCEPT EXISTING CONDUIT TO BUILDING. DISCONN

AND REMOVE EXISTING WIRING BACK TO EXISTING UTI

SERVICE LOCATION. EMPTY CONDUIT TO BE ABANDON

PLACE.

5 REFER TO SHEETS E-610 A & B FOR CONTINUATION OF

LINE

6 SEE SHEET E-603 FOR UPS SINGLE LINE DIAGRAM

7 CANOPY 4 INCLUDING LIGHTNING PROTECTION, LUMINA

INVERTERS, AND PANELS ARE PART OF BID OPTION 1

8 EXTENSION OF CANOPY 4 INCLUDING LIGHTNING

PROTECTION, LUMINARIES, INVERTERS, AND PANELS A

PART OF BID OPTION 2

R

EV

IS

ED

IN

A

C C

O R

D

AN

C E

W

IT

H A

M

EN

D M

EN

T

0 0

/2 3/

W

2Q R

R

_P la ns -0

E-200
E-504
E-505
E-506
E-601