W912QR24R0027_CF_Plans-0002.pdf
PDF 28 MB Posted
- Solicitation number
- W912QR24R0027
About this file
This document is a Request for Proposals (RFP) for the Renovation of the Des Moines Army Reserve Center (ARC) and Vehicle Maintenance Shop (VMS) in Des Moines, IA. The estimated construction cost is between $25,000,000.00 and $100,000,000.00. The North American Industry Classification System (NAICS) code is 236220, and the size determination is $45M. This is a full and open procurement that requires compliance with the HUBZone 10% price evaluation. The agency involved is the Department of the Army Corps of Engineers Engineering District Louisville. Offerors must register and provide online representations and certifications through the System for Award Management (SAM). Amendments will be available by download only.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
US Army Corps of Engineers ®
SOLICITATION NO.:
ISSUE DATE:
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T E
T R
A T
E C
H
IN
C
U
S H
W Y
L o u is v ill e
K Y
P h o n e
-5
F a x
(5
-5 w w w .t e tr a te c h .c o m
P a rk w a y L a n e
S u it e
P e a c h tr e e C o rn e rs
G
A
P h o n e
-7
CONTRACT NO.:
P2#:
FY24
G-001
C O
V E
R S
H E
E T
U S
A R
M Y
R E
S E
R V
E E
A R
M Y
P O
S T
R D
D
E S
M O
IN
E
S
IA
L O
U
IS
V
IL
L E
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
D R
IC
H
T E
R
J
U N
E
D E
S M
O
IN
E S
A R
M Y
R E
S E
R V
E C
E N
T E
R D
/B R
F P
D E
V E
L O
P M
E N
T F
O R
A R
M Y
R E
S E
R V
E C
E N
T E
R B
U
IL
D
IN
G
V E
H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
B U
IL
D
IN
G
P
F
Y
LOUISVILLE
10 JUNE 2024
US ARMY RESERVE, 225 E ARMY POST RD,
DES MOINES, IA 50315
DES MOINES ARMY RESERVE CENTER D/B RFP
DEVELOPMENT FOR ARMY RESERVE CENTER
BUILDING 100 & VEHICLE MAINTENANCE SHOP
BUILDING 101
P2# 515372 FY 2024
CERTIFIED FINAL RFP SUBMITTAL
3500 Parkway Lane Suite 500 Peachtree Corners, Georgia 30092
Pond & Company TETRA TECH, INC.
4967 US HWY 42
Louisville, KY 40222
515372
25 June 2024
W912QR24R0027-0002
Certified Final Design
W
2Q R
R
_C F_
Pl an s-
ARIMS: 200A Disposition: Maintain for 15 yrs after construction.
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T E
T R
A T
E C
H
IN
C
U
S H
W Y
L o u is v ill e
K Y
P h o n e
-5
F a x
(5
-5 w w w .t e tr a te c h .c o m
P a rk w a y L a n e
S u it e
P e a c h tr e e C o rn e rs
G
A
P h o n e
-7
G-002
S H
E E
T I
N D
E X
U S
A R
M Y
R E
S E
R V
E E
A R
M Y
P O
S T
R D
D
E S
M O
IN
E
S
IA
L O
U
IS
V
IL
L E
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
D e s ig n e r
A u th o r
D R
IC
H
T E
R
C h e c k e r
J
U N
E
C E
R T
IF
IE
D F
IN
A
L R
F P
S U
B M
IT
T
A L
D E
S M
O
IN
E S
A R
M Y
R E
S E
R V
E C
E N
T E
R D
/B R
F P
D E
V E
L O
P M
E N
T F
O R
A R
M Y
R E
S E
R V
E C
E N
T E
R B
U
IL
D
IN
G
V E
H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
B U
IL
D
IN
G
P
F
Y
SHEET LIST
GENERAL
G-001 COVER SHEET
G-002 SHEET INDEX
G-003 GENERAL NOTES, ABBREVIATIONS
CIVIL
C-001 GENERAL CIVIL LEGEND AND ABBREVIATIONS
C-002 CIVIL GENERAL NOTES
C-003 GENERAL CONSTRUCTION NOTES
C-004 GENERAL CONSTRUCTION NOTES
B-101 BORING LOCATION PLAN AND LOGS
B-102 BORING LOGS
V-100 SURVEY
CD100 OVERALL DEMOLITION PLAN
CD101 DEMOLITION PLAN
CD102 DEMOLITION PLAN
CS100 OVERALL SITE PLAN
CS101 SITE PLAN
CS102 SITE PLAN
CS200 TRUCK TURN PLAN
CS201 LOD STAKING PLAN
CS202 LOD STAKING PLAN
CS203 LOD STAKING PLAN
CS204 LOD STAKING TABLE
CG100 OVERALL GRADING PLAN
CG101 GRADING AND DRAINAGE PLAN
CG102 GRADING AND DRAINAGE PLAN
CU100 OVERALL UTILITY PLAN
CU101 UTILITY PLAN
CU102 UTILITY PLAN
CU103 UTILITY PLAN
ARCHITECTURAL
AD001 GENERAL NOTES - DEMOLITION
AD101 ARC - DEMOLITION OVERALL FIRST FLOOR PLAN
AD102 ARC - DEMOLITION OVERALL SECOND FLOOR PLAN
AD103 VMS - DEMOLITION FLOOR PLAN
AD104 ARC - DEMOLITION ROOF PLAN
AD120 FIRST FLOOR REFLECTED CEILING PLAN DEMOLITION
AD121 SECOND FLOOR REFLECTED CEILING PLAN DEMOLITION
AD201 ARC - DEMOLITION ELEVATIONS
AD202 ARC - DEMOLITION ELEVATIONS
AD203 VMS - DEMOLITION ELEVATIONS
A-101 ARC - OVERALL FIRST FLOOR PLAN
A-102 ARC - OVERALL SECOND FLOOR PLAN
A-103 VMS - NEW WORK FLOOR PLAN
A-104 ARC - FIRST FLOOR PLAN AREA 'A'
A-105 ARC - FIRST FLOOR PLAN AREA 'B'
A-106 ARC - FIRST FLOOR PLAN AREA 'C'
A-107 ARC - SECOND FLOOR PLAN AREA 'A'
A-108 ARC - SECOND FLOOR PLAN AREA 'B'
A-110 ARC - ROOF PLAN
A-120 FIRST FLOOR REFLECTED CEILING PLAN
A-121 SECOND FLOOR REFLECTED CEILING PLAN
A-201 ARC - ELEVATIONS
A-203 VMS - ELEVATIONS
A-301 ENLARGED FLOOR PLANS
A-601 DOOR TYPES, SCHEDULE AND DETAILS
A-602 WINDOW TYPES, SCHEDULE AND STOREFRONT ELEVATIONS
A-603 PARTITION TYPES
INTERIOR
I-101 FINISH LEGEND AND SCHEDULE - FIRST FLOOR
I-102 FINISH LEGEND AND SCHEDULE - SECOND FLOOR
I-111 FIRST FLOOR FURNITURE PLAN - AREA "A"
I-112 FIRST FLOOR FURNITURE PLAN - AREA "B"
I-113 FIRST FLOOR FURNITURE PLAN - AREA "C"
I-114 SECOND FLOOR FURNITURE PLAN - AREA"A"
I-115 SECOND FLOOR FURNITURE PLAN - AREA"B"
I-116 SECOND FLOOR FURNITURE PLAN AREA "C"
MECHANICAL
M-001 MECHANICAL GENERAL NOTES AND DESIGN CRITERIA
M-002 MECHANICAL ABBREVIATIONS AND LEGENDS
M-101 MECHANICAL CONCEPT PLAN - LEVEL 1
M-102 MECHANICAL CONCEPT PLAN - LEVEL 2
M-103 MECHANICAL CONCEPT PLANS - VMS
M-401 MECHANICAL HVAC ENLARGED PLANS
W
2Q R
R
_C F_
Pl an s-
DRAWING ABBREVIATIONS
INDEX OF DRAWINGS
BUILDING SUMMARY
NUMBERING SYSTEM:
XX100
DISCIPLINE:
C - CIVIL
L - LANDSCAPE
A - ARCHITECTURE
M - MECHANICAL
E - ELECTRICAL
P - PLUMBING
S - STRUCTURAL
K - FOOD SERVICE
DISCIPLINE MODIFIER
ANNOTATION CALLOUTS/DRAWING SYMBOLS
GENERAL NOTES
A ---------------------
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES
ACT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
BALC BALCONY
BB BASEBOARD
BC BOOKCASE
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C CONC CAST CONCRETE
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER)
BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED /
CONTRACTOR INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL
FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION AND
FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE
BOARD (INSULATION)
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FAS BD FASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT TREATED
WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-REINFORCED
GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE
AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING
CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND
RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONR
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC ROOM RECREATION ROOM
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
REFER TO A/E/C CAD STANDARD FOR
SHEET NUMBERINGSTANDARDS
REVISION
TAG
NORTH ARROW w/
TRUE NORTH
INDICATION
ROOM TAG
ELEVATION NUMBER
SECTION
EXTERIOR ELEVATION
ENLARGEMENT,
DETAIL
SPOT ELEVATION
LEVEL NAME
SHEET NUMBER
SHEET NUMBER
SHEET NUMBER
SHEET KEYNOTE
INTERIOR ELEVATION
SHEET NUMBER
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL FLASH SHEET METAL
(FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
ST STAIRS
STD STANDARD
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
SUB FL SUBFLOOR
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TR TELECOMMUNICATION ROOM
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
SHEET NUMBER WITHIN SERIES
A201
A204
A301
A401
ROOM
100'
LEVEL 01
100'
A
PLAN NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T E
T R
A T
E C
H
IN
C
U
S H
W Y
L o u is v ill e
K Y
P h o n e
-5
F a x
(5
-5 w w w .t e tr a te c h .c o m
P a rk w a y L a n e
S u it e
P e a c h tr e e C o rn e rs
G
A
P h o n e
-7
G-003
G E
N E
R A
L N
O T
E S
A
B B
R E
V
IA
T
IO
N S
U S
A R
M Y
R E
S E
R V
E E
A R
M Y
P O
S T
R D
D
E S
M O
IN
E
S
IA
L O
U
IS
V
IL
L E
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
G M
A C
K A
Y
B .E
L E
Y
D R
IC
H
T E
R
J C
L O
S E
J
U N
E
C E
R T
IF
IE
D F
IN
A
L R
F P
S U
B M
IT
T
A L
D E
S M
O
IN
E S
A R
M Y
R E
S E
R V
E C
E N
T E
R D
/B R
F P
D E
V E
L O
P M
E N
T F
O R
A R
M Y
R E
S E
R V
E C
E N
T E
R B
U
IL
D
IN
G
V E
H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
B U
IL
D
IN
G
P
F
Y
W
2Q R
R
_C F_
Pl an s-
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 20
P
M
K
H
F
D
B
TE
TR
A
TE
C H
, I N
C
U S
H W
Y
Lo ui sv ille
, K Y
Ph on e
(5
) 5
-5
Fa x (5
) 5
-5 w w w .te tra te ch .c om
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
U S
AR
M
Y R
ES
ER
VE
, 2
E
A R
M Y
PO
ST
R D
D
ES
M
O
IN
ES
, I
A
LO
U
IS
VI
LL
E
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
D .R
IC
H
TE
R
J
U N
E
D
ES
M
O
IN
ES
A
R M
Y R
ES
ER
VE
C
EN
TE
R D
/B R
FP
D
EV
EL
O
PM
EN
T
FO
R
A R
M Y
R
ES
ER
VE
C
EN
TE
R
B U
IL
D
IN
G
V
EH
IC
LE
M
AI
N
TE
N
AN
C
E
SH
O P
BU
IL
D
IN
G
P2
F Y:
D
.M . L
EC
KI
E
M .S
O
SA
A.
C
AS
TI
LL
O
E.
M
AN
G
IW
A
/ A . D
U
EH
R
18 19
C
ER
TI
FI
ED
F
IN
AL
R
FP
S U
BM
IT
TA
L
AT
AND
DIAMETER
AGGREGATE BASE COURSE
ABANDONED
ASPHALT CONCRETE
APPROXIMATELY
ARMY RESERVE DESIGN GUIDE
BASE CIVIL ENGINEERING
BUILDING
BENCHMARK
BOTTOM
BYPASS
COMPOST AMENDED VEGETATED FILTER STRIP
CATCH BASIN
CIVIL ENGINEER
CENTERLINE
CUBIC FEET
CORRUGATED METAL PIPE
CATHODIC PROTECTION TEST STATION
CONCRETE
CONTRACTING OFFICER'S REPRESENTATIVE
CEMENT TREATED BASE
DESIGN/BUILD
DROP INLET
DIAMETER
DUCTILE IRON PIPE
DESIGNER
DEPARTMENT OF NATURAL RESOURCES
EASTING
ENGINEERED DISPERSION
EXISTING GRADE
ELEVATION
EDGE OF PAVEMENT
EASEMENT
EXISTING
FINISHED FLOOR ELEVATION
FINISHED GRADE
FIRE HYDRANT
FEET
FOREIGN OBJECT AND DEBRIS
GRADED-CRUSHED AGGREGATE BASE COURSE
GEOGRAPHIC INFORMATION SYSTEM
GROUND SERVICE EQUIPMENT
HIGH DENSITY POLYETHYLENE PIPE
HORIZONTAL
INSIDE BOTTOM OF WALL
INSIDE DIAMETER
INVERT ELEVATION
INCH
INCORPORATED
INVERT
IOWA DEPARTMENT OF TRANSPORTATION
IRON PIN FOUND
IRON PIN SET
INSTALLATION RADIATION SAFETY OFFICER
JUNCTION BOX
CONTRACTING OFFICER
LINEAR FEET
LIMITS OF DISTURBANCE
LIGHTNING PROTECTION
MAXIMUM
MILITARY EQUIPMENT PARKING
MINIMUM
MOBILE KITCHEN TRAILER
MONUMENT
MONITORING WELL
NORTHING
NOW OR FORMERLY
NUMBER
NOT TO SCALE
ON CENTER
ON CENTER EACH WAY
OUTSIDE DIAMETER
OFFSET
OIL/WATER SEPARATOR
PORTLAND CEMENT CONCRETE
POST INDICATOR VALVE
POINT OF BEGINNING
PRIVATELY OWNED VEHICLE
PROPOSED
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POLYVINYL CHLORIDE
QUALITY CONTROL
REINFORCED CONCRETE PIPE
RADIUS POINT
RIGHT OF WAY
SQUARE FEET
SPECIFICATIONS
SQUARE
SANITARY SEWER
SANITARY SEWER MANHOLE
STORM DRAIN
STATION
STANDARD
STORMWATER POLLUTION PREVENTION PLAN
TEMPORARY BENCHMARK
TYPICAL
VERTICAL
WATER METER
WATER VALVE
WELDED WIRE FABRIC
Ø
ABC
ABND
AC
APPROX.
ARDG
BCE
BLDG
BM
BOT
BP
CAVFS
CB
CE
CF
CMP
CPTS
CONC
COR
CTB
D/B
DI
DIA
DIP
DES
DNR
E
ED
EG
EL OR ELEV
EP
ESMT
EX
FFE
FG
FH
FT
FOD
GCAB
GIS
GSE
HDPE
HORZ
IBW
ID
IE
IN
INC
INV
IOWADOT
IPF
IPS
IRSO
JB
KO
LF
LOD
LP
MAX
MEP
MIN
MKT
MON
MW
N N/F
NO
NTS
OC
OCEW
OD
OFST
OWS
PCC
PIV
POB
POV
PROP
PSF
PSI
PVC
QC
RCP
RP
R/W
SF
SPEC
SQ
SS
SSMH
ST
STA
STD
SWPPP
TBM
TYP
VERT
WM
WV
WWF
ABBREVIATIONS
DESCRIPTIONPROPOSED ITEM
LEGEND
EXISTING ITEM
SHEET NAMING CONVENTION
C-001
2 DIGIT SEQUENTIAL # (01-99)
(FIRST DIGIT INDICATES PLAN
TYPE. SECOND DIGIT INDICATES
FLOOR)
1 DIGIT SHEET TYPE DESIGNATOR
0 - GENERAL
2 - PROFILES
3 - SECTIONS
4 - ENLARGED PLANS
6 - SCHEDULES AND DIAGRAMS
9 - 3D VIEWS (ISO, PERSPECTIVES,
PHOTOS)
2 DIGIT DESCIPLINE
DESIGNATOR
(IF ONLY ONE LETTER IS
USED, THE SECOND
LETTER IS REPLACED
WITH A DASH "-" AS A
PLACEHOLDER)**
PROJECT CONTACTS:
CIVIL ENGINEER FOR THIS PROJECT IS:
POND & COMPANY
3500 PARKWAY LANE, SUITE 500
PEACHTREE CORNERS, GA 30092
P: (678) 336.7740
CONTACT: EFRAIM MANGIWA, PE
SURVEYOR FOR THIS PROJECT IS:
LT LEON ASSOCIATES. INC
500 EAST LOCUST STREET SUITE 400
DES MOINES, IA 50309
P: (515) 422 7016
CONTACT: IAN MCKENZIE / LUIS LEON
GEOTECH FOR THIS PROJECT IS:
NAME: BRAUN INTERTEC
3000 JUSTIN DRIVE, SUITE K
URBANDALE, IA 50322
P: (319) 432 9656
CONTACT: ANDREW SCHWEIZER, PE
1 - PLANS
5 - DETAILS
7 - USER DEFINED
8 - USER DEFINED
NOTE:
1. NOT ALL ABBREVIATIONS SHOWN WILL BE USED ON THIS
PROJECT. WITH
WATER TO CEMENT
YEAR
W/ W/C
YR
C-001
G
EN
ER
AL
C
IV
IL
L
EG
EN
D A
N D
AB
BR
EV
IA
TI
O
N S
CO
D
S
E
X X
San San San
StS StS StS
OHE OHE OHE
E E E
FO FO FO
G G G
W W W
T T T
DECIDUOUS TREE
CONIFEROUS SHRUB
ELECTRICAL TRANSFORMER
GUY WIRE
LIGHT POLE
SIGN
MAILBOX
WATER VALVE
FIRE HYDRANT
SANITARY OR STORM CLEANOUT
SANITARY MANHOLE
STORM MANHOLE
ELECTRICAL METER
AIR CONDITIONING UNIT
PCC PAVEMENT
ASPHALT PAVEMENT
TELE-COMMUNICATION SERVICE
FIRE LINE
NATURAL GAS SERVICE
FIBER OPTIC SERVICE
OVERHEARD ELECTRICAL SERVICE
STORM SEWER
SANITARY SEWER
6-FOOT CHAIN LINK FENCE W/ BARB WIRE
UNDERGROUND ELECTRICAL SERVICE
BOLLARD
X X X
S
CO
SS SS
G
F F F
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HEAVY VEHICLE RATED
CONCRETE PAVEMENT
NON-VEHICULAR CONCRETE PAVEMENT
MKT CONCRETE PAVEMENT
GRAVEL DRIVEWAY
N/A
MKT DRIVEWAY
CONCRETE PAVEMENT
N/A
N/A
N/A
N/A
N/A
FULL DEPTH
ASPHALT PAVEMENT
COMMUNICATION HANDHOLE
N/A
LIMITS OF DISTURBANCELOD LOD LODN/A
N/A H
FO FO
W
2Q R
R
_C F_
Pl an s-
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 20
P
M
K
H
F
D
B
TE
TR
A
TE
C H
, I N
C
U S
H W
Y
Lo ui sv ille
, K Y
Ph on e
(5
) 5
-5
Fa x (5
) 5
-5 w w w .te tra te ch .c om
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
U S
AR
M
Y R
ES
ER
VE
, 2
E
A R
M Y
PO
ST
R D
D
ES
M
O
IN
ES
, I
A
LO
U
IS
VI
LL
E
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
D .R
IC
H
TE
R
J
U N
E
D
ES
M
O
IN
ES
A
R M
Y R
ES
ER
VE
C
EN
TE
R D
/B R
FP
D
EV
EL
O
PM
EN
T
FO
R
A R
M Y
R
ES
ER
VE
C
EN
TE
R
B U
IL
D
IN
G
V
EH
IC
LE
M
AI
N
TE
N
AN
C
E
SH
O P
BU
IL
D
IN
G
P2
D
.M . L
EC
KI
E
M .S
O
SA
A.
C
AS
TI
LL
O
E.
M
AN
G
IW
A
/ A . D
U
EH
R
18 19
C
ER
TI
FI
ED
F
IN
AL
R
FP
S U
BM
IT
TA
L
GENERAL CIVIL NOTES
1. THE CONTRACTOR MUST COMPLY WITH ALL CITY, COUNTY, STATE AND
FEDERAL REGULATIONS APPLICABLE TO CONSTRUCTION OF THIS SITE.
2. ALL LABOR, MATERIALS, AND METHODS OF CONSTRUCTION MUST BE IN
STRICT ACCORDANCE WITH THE MINIMUM ENGINEERING AND
CONSTRUCTION STANDARDS ADOPTED BY THE U.S. ARMY CORPS OF
ENGINEERS (USACE). WHERE CONFLICTS OR OMISSIONS EXIST, THE USACE
STANDARDS MUST DICTATE. SUBSTITUTIONS AND DEVIATION FROM PLANS
AND SPECIFICATIONS MUST BE PERMITTED ONLY WHEN WRITTEN APPROVAL
HAS BEEN ISSUED BY THE CONTRACTING OFFICER'S REPRESENTATIVE (COR).
3. ALL DIMENSIONS ARE TAKEN FROM/TO FENCE LINES, CENTERLINE OF
UTILITY, CENTER OF MANHOLE OR CATCH BASIN, CENTERLINE OF ROAD,
FACE OF BUILDING, FACE OF CURB, FACE OF WALL, OR CENTERLINE OF
STRIPING UNLESS OTHERWISE NOTED.
4. EXISTING CONDITIONS SHOWN ARE BASED UPON GIS INFORMATION
PROVIDED BY DES MOINES ARMY RESERVE CENTER. EXISTING UTILITY
INFORMATION SHOULD BE CONSIDERED APPROXIMATE AND MUST BE
VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION OR ORDERING
MATERIALS.
5. ALL REQUIRED EROSION AND SEDIMENT CONTROL MEASURES MUST BE
PROVIDED, INSTALLED, AND MAINTAINED NOT SHOWN ON THE APPLICABLE
EROSION, SEDIMENTATION AND POLLUTION CONTROL PLANS CONTAINED
WITHIN THESE CONSTRUCTION DOCUMENTS.
6. CONTRACTOR TO MOVE ALL CONSTRUCTION DEBRIS OFF DES MOINES ARMY
RESERVE CENTER AND DISPOSE DEBRIS AT A LEGAL, PERMITTED LANDFILL
CONSISTENT WITH ALL LOCAL, STATE, AND FEDERAL REQUIREMENTS.
7. NO BURNING IS ALLOWED ON DES MOINES ARMY RESERVE CENTER.
8. CONTRACTOR TO ENSURE ALL EXISTING TOPS OF MANHOLES AND VALVE
BOXES ARE RAISED OR LOWERED TO BE FLUSH WITH FINISHED GRADES,
UNLESS NOTED OTHERWISE.
9. ALL PAVEMENT AND SIDEWALKS MUST BE CONSTRUCTED FLUSH WITH
EXISTING, WITH NO PONDING OF STORMWATER, UNLESS NOTED OTHERWISE.
10. CONTRACTOR MUST GRADE ALL DISTURBED AREAS TO ENSURE POSITIVE
DRAINAGE AWAY FROM ALL BUILDINGS AND TO DRAINAGE STRUCTURES OR
DITCHES. NATURAL FLOW OF SURROUNDING WATERS MUST NOT BE
DISTURBED DURING CONSTRUCTION, UNLESS SHOWN OTHERWISE.
11. CONTRACTOR MUST VERIFY ALL EXISTING CONDITIONS, COORDINATES, AND
DIMENSIONAL INFORMATION PRIOR TO CONSTRUCTION. THE CONTRACTOR
MUST BRING ALL DISCREPANCIES TO THE ATTENTION OF THE CONTRACTING
OFFICER'S REPRESENTATIVE ( COR) PRIOR TO STARTING CONSTRUCTION.
12. THE CONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING INSTALLATION
OF ALL UTILITIES WITH THOSE THAT ARE EXISTING. IF EXISTING UTILITIES
ARE IN CONFLICT WITH UTILITIES, THE SITE CONTRACTOR MUST NOTIFY THE
COR BEFORE PROCEEDING WITH CONSTRUCTION.
13. ALL TOPSOIL AND EXCAVATED MATERIAL MUST BE STOCKPILED IN AN
APPROVED AREA DURING CONSTRUCTION. EXCESS OR UNUSABLE TOPSOIL
MUST BE DISPOSED OF OFF-SITE IN A MANNER THAT IS LEGAL AND
CONSISTENT WITH ALL LOCAL, STATE AND FEDERAL REQUIREMENTS.
14. THE LOCATION OF ALL EXISTING UTILITIES AND STORM DRAINAGE SHOWN ON
THE PLANS HAVE BEEN DETERMINED FROM THE BEST INFORMATION
AVAILABLE AND ARE GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR.
THE ENGINEER ASSUMES NO RESPONSIBILITY FOR INACCURACY. PRIOR TO
THE START OF ANY CONSTRUCTION ACTIVITY IT MUST BE THE
CONTRACTOR'S RESPONSIBILITY TO NOTIFY AND ARRANGE THE PROPOSED
WORK AND UTILITY RELOCATIONS WITH THE COR AND UTILITY PROVIDERS.
THE CONTRACTOR MUST EXERCISE CAUTION WHEN CROSSING
UNDERGROUND UTILITIES, WHETHER SHOWN ON THE PLAN OR LOCATED BY
THE UTILITY COMPANY. ALL UTILITIES WHICH INTERFERE WITH THE
CONSTRUCTION MUST BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER'S REPRESENTATIVE (COR). ANY FEES ASSOCIATED
WITH UTILITY RELOCATIONS MUST BE BORNE BY THE CONTRACTOR IN
ACCORDANCE WITH RESPECTIVE UTILITY COMPANY STANDARDS. THE
CONTRACTOR WILL COORDINATE DISCONNECTION OF EXISTING UTILITIES
WITH THE COR AND APPROPRIATE UTILITY PROVIDER.
15. UTILITIES INDICATED MUST BE CONSTRUCTED IN ACCORDANCE WITH THE
APPLICABLE PROVISIONS OF THE SPECIFICATIONS. GRADING MUST BE AS
INDICATED, AND MUST PRODUCE A FINISHED SURFACE WITH NO PONDING OF
WATER, READY TO RECEIVE PLANTING MATERIALS OR GRASSING.
16. IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL
REQUIRED PERMITS ARE OBTAINED AND IN HAND BEFORE BEGINNING ANY
CONSTRUCTION. NO CONSTRUCTION OR FABRICATION OF ANY ITEM MUST
BEGIN UNTIL THE CONTRACTOR HAS RECEIVED ALL PERMITS AND ANY OTHER
REQUIRED APPROVALS FROM ALL OF THE PERMITTING AND ANY OTHER
REGULATORY AUTHORITIES. ANY PENALTIES, STOP WORK ORDERS OR
ADDITIONAL WORK RESULTING FROM THE CONTRACTOR BEING IN VIOLATION
OF THE REQUIREMENTS ABOVE, MUST BE FULLY BORNE BY THE
CONTRACTOR.
17. ALL CONTRACTORS/SUBCONTRACTORS THAT WILL BE ENGAGED IN LAND
DISTURBING ACTIVITIES MUST COMPLY WITH ALL EROSION, SEDIMENTATION
AND POLLUTION CONTROL AND STORMWATER POLLUTION PREVENTION
REQUIREMENTS CONTAINED THROUGHOUT THE DRAWINGS, SPECIFICATIONS,
AND PERMITS.
18. AREAS DISTURBED BY THE CONTRACTOR, WHICH ARE NOT PART OF THIS
PROJECT, MUST BE RETURNED TO PRE-CONSTRUCTION OR BETTER
CONDITION PRIOR TO THE COMPLETION OF THE PROJECT AS DETERMINED BY
THE COR.
19. THE CONTRACTOR'S MEANS, METHODS, SEQUENCE, TECHNIQUES OR
PROCEDURES IN PERFORMING THE WORK IS SOLELY THE RESPONSIBILITY OF
THE CONTRACTOR, WHO IS ALSO RESPONSIBLE FOR COMPLYING WITH ALL
HEALTH AND SAFETY PRECAUTIONS AS REQUIRED BY THE APPLICABLE
REGULATORY AGENCY.
20. THE DESIGN ADEQUACY AND SAFETY OF ALL BRACING, SHORING AND
TEMPORARY SUPPORTS, ETC. ARE THE SOLE RESPONSIBILITY OF THE
CONTRACTOR.
21. PROTECT ALL EXISTING FEATURES AND EXISTING LANDSCAPING THAT WILL
REMAIN. ANY ITEM DAMAGED DURING THE PERFORMANCE OF THE WORK
MUST BE RESTORED TO PRE-CONSTRUCTION CONDITION, OR REPLACED
WITH NEW AT THE CONTRACTOR'S EXPENSE. CONTRACTOR MUST TAKE
PRECAUTIONS TO AVOID OVERLOADING PAVEMENTS WHICH WILL REMAIN.
22. CONTRACTOR MUST INSPECT ALL SEDIMENT AND EROSION CONTROL
MEASURES DAILY AND DURING PROLONGED PERIODS OF CONTINUOUS
RAINFALL EVENTS TO ENSURE THAT ALL CONTROLS ARE FUNCTIONING
PROPERLY. DAMAGED CONTROLS MUST BE REPLACED BY THE END OF THE
WORKDAY.
23. EACH SHEET IS PART OF A MULTI-SHEET SET OF CONSTRUCTION PLANS AND
MUST BE READ WITH THE FULL SET TO BEST ENSURE PROPER
INTERPRETATION.
24. SHEET KEYNOTES ON THE PLANS ARE SPECIFIC TO THAT SHEET ONLY.
MISSING SEQUENTIAL NUMBERS DO NOT APPLY TO THAT SHEET.
25. THE CONTRACTOR LAYDOWN AREA WILL BE PLACED WITHIN THE POV
PARKING AREA. THE CONTRACTOR MUST PROVIDE A STAGING AND PHASING
AREA WITH APPROVAL FROM THE COR.
GENERAL CIVIL DEMOLITION NOTES
1. "DEMOLISH" MEANS TO REMOVE AN OBJECT AS INDICATED ON THE
DRAWINGS. RESTORE GRADES AND SURFACE IMPROVEMENTS TO MATCH
EXISTING CONDITIONS OR THE REQUIREMENTS OF WORK, WHICHEVER IS
APPLICABLE.
2. SAWCUT TO FULL DEPTH AND REMOVE FROM GOVERNMENT PROPERY
CONCRETE SLABS IN THE LOCATIONS INDICATED ON THE PLANS. CONCRETE
SLABS SHALL BE REMOVED TO SAWED EDGES.
3. THE EROSION AND SEDIMENTATION CONTROL MEASURES AND TEMPORARY
CONSTRUCTION FENCING MUST BE IN PLACE PRIOR TO COMMENCEMENT OR
CONCURRENT WITH DEMOLITION.
4. CONTRACTOR MUST ESTABLISH SURVEY CONTROL NETWORK OUTSIDE
LIMITS OF DEMOLITION PRIOR TO COMMENCEMENT OF WORK. THIS WORK
MUST BE PERFORMED BY LICENSED & REGISTERED IOWA LAND SURVEYOR.
5. ALL DEMOLITION WORK MUST BE COORDINATED WITH CONTRACTOR'S
SCHEDULE, LOGISTICS PLAN (APPROVED BY COR), EROSION, SEDIMENTATION
AND POLLUTION CONTROL PLAN PRIOR TO WORK.
6. ALL TEMPORARY FENCING DEMOLISHED FROM SITE TO A LEGAL LANDFILL.
7. TRASH AND LITTER TO BE FULLY REMOVED FROM SITE TO A LEGAL LANDFILL.
GENERAL CIVIL SITE NOTES
1. CONTRACTOR MUST FURNISH AND MAINTAIN ANY AND ALL NECESSARY
BARRICADES AROUND THE WORK AND PROVIDE PROTECTION AGAINST
WATER DAMAGE AND SOIL EROSION.
2. PAVEMENT MARKINGS, INCLUDING ANY STANDARD HANDICAP SYMBOLS,
PARKING STRIPING, STOP BARS, AND TRAFFIC ARROWS, MUST BE PAINTED
ON PAVEMENT AT LOCATIONS SHOWN. THE LOT MUST BE COMPLETELY SHUT
DOWN AND LIMITED TO STAGING AND LAYDOWN AREA DURING THE
MILLING/OVERLAY AND REPLACEMENT OF THE PARKING LOT PAVEMENT.
3. ALL TRAFFIC SIGNS AND PAVEMENT MARKINGS AND SIGNAGE MUST
CONFORM TO THE MOST RECENT IOWA DEPARTMENT OF TRANSPORTATION
(IOWADOT) AND MUTCD STANDARDS AND SPECIFICATIONS.
GRADING AND DRAINAGE NOTES
1. POSITIVE DRAINAGE MUST BE MAINTAINED AT ALL TIMES TO PREVENT
SATURATION OF EXPOSED SOILS IN CASE OF SUDDEN RAINS, UNTIL FINISHED
GRADING IS ACHIEVED. CONTRACTOR MUST LOCATE ALL EXISTING UTILITIES
PRIOR TO ANY EXCAVATION.
2. CONTRACTOR MUST PROVIDE ALL PERIMETER EROSION AND SEDIMENT
CONTROL MEASURES PRIOR TO ANY SITE CLEARING OR EXCAVATION.
3. ALL BACKFILL AND FILL MATERIAL MUST BE FREE OF ORGANIC MATTER AND
WASTE.
4. THE CONTRACTOR MUST REMOVE ALL EROSION AND SEDIMENT CONTROL
FENCING FROM THE SITE PRIOR TO FINAL PROJECT ACCEPTANCE, AND MUST
SMOOTH THE GROUND SURFACE WHERE THE FENCE WAS REMOVED; THEN,
MULCH OR SEED & STRAW (SEASON APPROPRIATE GRASS) THE RESTORED
SURFACE AS SUNLIGHT CONDITIONS WARRANT.
5. CONTRACTOR MUST MARK, PRESERVE AND PROTECT ALL SURVEY
BENCHMARKS.
6. IF ANY BENCHMARKS ARE DAMAGED OR DEMOLISHED, ANY RELOCATED
BENCHMARK MUST BE RESET OR REESTABLISHED BY A LICENSED
PROFESSIONAL SURVEYOR AND PROVIDED ON AS-BUlLTS.
7. ALL CUT AND FILL SLOPES MUST BE 3:1 OR FLATTER (SEE PLANS).
8. ALL SPOT ELEVATIONS NOTED ARE FINISH GRADE.
GENERAL UTILITY NOTES:
1. UTILITY SUBCONTRACTORS ARE RESPONSIBLE FOR COORDINATING ALL
BUILDING CONNECTIONS WITH BUILDING CONTRACTOR AND THE
INFORMATION PROVIDED ON MECHANICAL, FIRE PROTECTION AND
ELECTRICAL SHEETS.
2. CONTRACTOR MUST CONTACT AND SUBMIT 811 DIG PERMIT TO IDENTIFY THE
LOCATION OF UTILITIES PRIOR TO COMMENCEMENT OF WORK.
3. PROVIDE A MINIMUM NOTICE OF 30 DAYS FOR ALL REQUIRED UTILITY
SHUTDOWNS FOR UTILITY CONNECTIONS WITH THE CONTRACTING OFFICER.
4. ALL EQUIPMENT MUST BE PAINTED TO MATCH BASE STANDARD.
5. ANY CHANGES TO UTILITY DESIGN MUST BE APPROVED BY THE
CONTRACTING OFFICER IN WRITING.
6. CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND PAYING ALL UTILITY
CONNECTION FEES AND OBTAINING ALL PERMITS REQUIRED FOR THE UTILITY
CONSTRUCTION AND CONNECTIONS. THIS INCLUDES ALL FEES ASSOCIATED
WITH CONNECTION CHARGES AND METERS.
7. ALL UNDERGROUND UTILITIES ARE SUBJECT TO ACCEPTANCE TESTING AND
INSPECTION METHODS DETAILED IN THE SPECIFICATIONS, WHICH MAY
INCLUDE VIDEO CAMERA INSPECTION. COORDINATE CAMERA AND
EQUIPMENT WITH THE SITE SECURITY MANAGER AND CONTRACTING OFFICER
PRIOR TO BRINGING ANY PHOTOGRAPHY OR VIDEO EQUIPMENT ON SITE.
8. ALL WATER & SEWER CONSTRUCTION WORK ON THIS PROJECT MUST BE
PERFORMED IN ACCORDANCE WITH ALL APPLICABLE INDUSTRY CODES AND
STANDARDS. THESE CODES AND STANDARDS INCLUDE BUT ARE NOT LIMITED
TO THE FOLLOWING: AMERICAN WATER WORKS ASSOCIATION (AWWA),
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), AMERICAN SOCIETY FOR
TESTING AND MATERIALS (ASTM), OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION (OSHA), AMERICAN ASSOCIATION OF STATE HIGHWAY AND
TRANSPORTATION OFFICIALS (AASHTO), NATIONAL FIRE PROTECTION
ASSOCIATION (NFPA), UNIFIED FACILITIES CRITERIA (UFC), ENVIRONMENTAL
PROTECTION AGENCY (EPA) AND USACE EM 385-1-1 SAFETY AND HEALTH
REQUIREMENT MANUAL. THE MOST STRINGENT MUST BE APPLIED IN ALL
CASES ESPECIALLY FOR ISSUES RELATED TO SAFETY.
WATER UTILITY NOTES:
1. THRUST BLOCKS OR JOINT RESTRAINTS ARE REQUIRED AT ALL TEES, BENDS,
OR ELBOWS OF PRESSURIZED PIPING IN ACCORDANCE WITH THE DRAWINGS,
SPECIFICATIONS, AND MANUFACTURER'S RECOMMENDATIONS. SEE SHEET
CU502 FOR TYPICAL THRUST BLOCK DETAIL. MECHANICAL JOINT RESTRAINTS
ARE ALLOWED IN AREAS WHERE PROXIMITY OF ADJACENT UTILITIES OR
STRUCTURES WILL MAKE PLACEMENT OF THRUST BLOCKS DIFFICULT. USE
OF JOINT RESTRAINTS MUST BE APPROVED BY THE CONTRACTING OFFICER.
2. WATER LINES MUST BE INSTALLED A MINIMUM OF 3 FEET BEHIND THE EDGE
OF PAVEMENT OR FACE OF CURB UNLESS INDICATED OTHERWISE. SEE
SPECIFICATIONS FOR ADDITIONAL CLEARANCE REQUIREMENTS FOR WATER
PIPING.
3. FIRE HYDRANTS MUST BE INSTALLED A MINIMUM OF 3 FEET AND A MAXIMUM
OF 6 FEET FROM EDGE OF PAVEMENT OR FACE OF CURB AND A MINIMUM OF 1
FEET FROM EDGE OF SIDEWALK UNLESS INDICATED OTHERWISE. A RADIUS
OF 3 FEET AROUND THE HYDRANT SHALL BE KEPT CLEAR FOR FIRE
DEPARTMENT ACCESS. AREA BETWEEN CURB AND HYDRANTS SHALL BE
KEPT CLEAR OF OBSTRUCTIONS. FIRE HYDRANTS SHALL BE PAINTED BROWN
TO MATCH DES MOINES RESERVE CENTER STANDARDS. PLACE COLORED
BAND(S) ON EACH FIRE HYDRANT INDICATING THE CLASS OF THE HYDRANT
DESIGNATED IN NFPA 291 (IE CLASS AA, A, B, OR C).
SANITARY UTILITY NOTES:
1. ALL SANITARY SEWER BUILDING CONNECTIONS SHALL BE MADE USING 4-INCH
LINES UNLESS INDICATED OTHERWISE.
2. ALL SANITARY LINES ARE TO BE LAID AT A UNIFORM SLOPE FROM THE
BUILDING CONNECTIONS TO THE CONNECTING SEWER AND BETWEEN UTILITY
STRUCTURES.
3. IF MANHOLES ARE INDICATED ON SANITARY LINES, A MINIMUM 0.1 FEET DROP
IN ELEVATION BETWEEN THE INCOMING AND OUTGOING SEWER SHALL BE
PROVIDED IN EACH MANHOLE UNLESS INDICATED OTHERWISE. INVERT FLOW
CHANNELS SHALL BE CONSTRUCTED TO PROVIDE SMOOTH AND UNIFORM
SLOPE WITH GRADUAL TRANSITION SECTIONS.
UTILITY STRUCTURE NOTES:
1. MANHOLE RIM ELEVATION SHALL BE FLUSH WITH FINAL GRADE, UNLESS
NOTED OTHERWISE.
2. COVERS AND CASTINGS OF MANHOLES AND STRUCTURES SHALL BE
STAMPED PER THE APPROPRIATE UTILITY TYPE OR PER THE LOCAL
STANDARDS, AND SHALL BE STAMPED PER THE ORIGIN OF MANUFACTURE.
3. COVERS AND CASTINGS SHALL BE TAMPER-PROOF FOR ELECTRICAL AND
COMMUNICATIONS MANHOLES/HANDHOLES STRUCTURES LOCATED IN
PEDESTRIAN AREAS, EASEMENT AREAS, AND AREAS WITH SPECIAL SECURITY
RESTRICTIONS. COORDINATE WITH THE CONTRACTING OFFICER AND
INSTALLATION SECURITY PRIOR TO INSTALLATION TO ENSURE INSTALLATION
SECURITY KNOWS HOW TO OPERATE THE TAMPER-PROOF STRUCTURES.
MANHOLE FRAME ADJUSTMENT NOTES:
1. AREA REQUIRING MANHOLE ADJUSTMENT SHALL BE SAWCUT SQUARE OR
CIRCULAR 12-INCH MINIMUM AROUND MANHOLE FRAME.
2. MANHOLE COVER AND FRAME SHALL BE RAISED TO FINISH GRADE BY
INSTALLING PRECAST MANHOLE ADJUSTMENT RINGS AND LEVELING
MORTAR.
3. GRADE ADJUSTMENT AREA SHALL BE BACKFILLED WITH EARLY STRENGTH
PCC.
C-002
C
IV
IL
G
EN
ER
AL
N
O
TE
S
W
2Q R
R
_C F_
Pl an s-
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 20
P
M
K
H
F
D
B
TE
TR
A
TE
C H
, I N
C
U S
H W
Y
Lo ui sv ille
, K Y
Ph on e
(5
) 5
-5
Fa x (5
) 5
-5 w w w .te tra te ch .c om
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
U S
AR
M
Y R
ES
ER
VE
, 2
E
A R
M Y
PO
ST
R D
D
ES
M
O
IN
ES
, I
A
LO
U
IS
VI
LL
E
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
D .R
IC
H
TE
R
J
U N
E
D
ES
M
O
IN
ES
A
R M
Y R
ES
ER
VE
C
EN
TE
R D
/B R
FP
D
EV
EL
O
PM
EN
T
FO
R
A R
M Y
R
ES
ER
VE
C
EN
TE
R
B U
IL
D
IN
G
V
EH
IC
LE
M
AI
N
TE
N
AN
C
E
SH
O P
BU
IL
D
IN
G
P2
D
.M . L
EC
KI
E
M .S
O
SA
A.
C
AS
TI
LL
O
E.
M
AN
G
IW
A
/ A . D
U
EH
R
18 19
C
ER
TI
FI
ED
F
IN
AL
R
FP
S U
BM
IT
TA
L
GENERAL PROJECT NOTES:
1. CONTRACTORS MUST KEEP ALL ROADS AND STREETS CLEAN OF
CONSTRUCTION DEBRIS, MUD, ETC. AT ALL TIMES. CONTRACTOR MUST
PROVIDE EQUIPMENT AND PERSONNEL TO CLEAN ANY STREETS AS
REQUESTED BY THE CONTRACTING OFFICER. CONTRACTOR IS
RESPONSIBLE FOR ALL REPAIRS TO STREETS, PARKING AREAS, AND BASE
OR GOVERNMENT PROPERTY, DUE TO DAMAGE BY THEIR CONSTRUCTION
ACTIVITIES. CONTRACTOR MUST PROVIDE PHOTOGRAPHS AND/OR VIDEO
RECORDING OF THE EXISTING CONDITIONS. CONTRACTOR MUST
COORDINATE WITH THE CONTRACTING OFFICER FOR A PRE-CONSTRUCTION
VIDEO DETAILING THE EXISTING CONDITION OF ACCESS POINTS, HAUL
ROUTES, AND LAYDOWN AREAS TO BE PERFORMED. SEE CONTRACT
SPECIFICATIONS.
2. CONTRACTOR MUST COORDINATE WITH CONTRACTING OFFICER PRIOR TO
CONNECTION TO EXISTING OR NEW FIRE HYDRANTS FOR TEMPORARY
CONSTRUCTION WATER. PROVIDE QUICK DISCONNECT, BACK FLOW
PREVENTOR, AND SHUT OFF VALVE WITH METER ON 2.5-INCH HOSE
CONNECTION ONLY.
3. CONTRACTOR MUST COMPLETE THE STORMWATER POLLUTION
PREVENTION PLAN (SWPPP). REFER TO THE SPECIFICATIONS FOR DETAILS
ON STORMWATER POLLUTION PREVENTION MEASURES FOR THIS PROJECT.
CONTRACTOR IS RESPONSIBLE FOR FOLLOWING ALL IOWA DNR
REQUIREMENTS FOR EROSION CONTROL. CONTRACTOR IS RESPONSIBLE
FOR COORDINATING ALL REQUIREMENTS WITH STATE AND LOCAL
AUTHORITIES AND DOCUMENTS TO BE SUBMITTED FOR PERMITTING.
4. CONTRACTOR MUST STOP WORK IMMEDIATELY AND CONTACT THE
CONTRACTING OFFICER IF A UTILITY LINE IS DISTURBED.
5. ALL WORK OUTSIDE OF BASE PROPERTY MUST BE SUBJECT TO INSPECTION
BY AUTHORIZED PERSONNEL OF STATE, LOCAL, AND GOVERNMENT
REGULATORY AGENCIES AND THE CONTRACTING OFFICER.
6. ALL WORK MUST BE CONDUCTED IN ACCORDANCE WITH THE PLANS AND
SPECIFICATIONS, STATE, LOCAL, AND GOVERNMENT CODES, ORDINANCES,
AND REGULATIONS. IN CASE OF CONTRADICTION OR DISCREPANCY
BETWEEN REQUIREMENTS, CONTRACTOR MUST INCORPORATE
WHICHEVER IS MOST STRINGENT. WHERE A QUESTION REMAINS ON WHICH
REQUIREMENT IS MOST STRINGENT, CONTRACTOR MUST SUBMIT ISSUE TO
THE CONTRACTING OFFICER IN WRITING. THE DECISION OF THE
CONTRACTING OFFICER MUST BE CONSIDERED FINAL.
7. PROVIDE A TEMPORARY FENCE AROUND THE CONSTRUCTION ZONE,
STAGING AREA, AND LAYDOWN AREAS AS NEEDED FOR SECURITY OF
EQUIPMENT AND MATERIALS AS DIRECTED BY CONTRACTING OFFICER.
CONTRACTOR MUST SUBMIT A TEMPORARY FENCE LOCATION TO COR FOR
APPROVAL PRIOR TO INSTALLATION.
8. COORDINATE THE DISCONNECTION OF UTILITIES THROUGH THE
CONTRACTING OFFICER. DEMOLITION MUST NOT BEGIN UNTIL WRITTEN
BASE APPROVAL IS RECEIVED. ALL EXISTING UTILITIES ARE TO BE
TERMINATED AT THEIR POINT OF CONNECTION TO THE MAINS. WHERE
CONNECTIONS OF PROVIDE UTILITIES TO EXISTING UTILITIES ARE SHOWN
ON THE PLANS, THE CONTRACTOR MUST EXPOSE THE EXISTING LINES AT
THE CONNECTIONS TO VERIFY THE LOCATIONS AND DEPTHS PRIOR TO
EXCAVATION FOR THE PROVIDE LINES.
9. THE CONTRACTOR MUST EXPOSE, VERIFY AND BACKFILL ALL EXISTING
UNDERGROUND UTILITIES AND STRUCTURES AT UTILITY CROSSINGS PRIOR
TO EXCAVATION OF PIPELINE TRENCH. UTILITY CROSSINGS AT A DEPTH
GREATER THAN 12-INCHES BELOW TRENCH BOTTOM DO NOT NEED TO BE
EXPOSED. UTILITY ALIGNMENT AND GRADE MAY BE CHANGED IF THERE ARE
CONFLICTS WITH ANY EXISTING UNDERGROUND UTILITIES AND
STRUCTURES, WHETHER SHOWN ON THE PLANS OR NOT. COORDINATE
WITH THE CONTRACTING OFFICER AND DESIGN ENGINEER.
10. FACILITIES IN THE UTILITY CORRIDOR MUST BE RESTORED UPON
COMPLETION OF CONSTRUCTION. PAVEMENTS, FENCES, VEGETATION, AND
OTHER LANDSCAPING MUST BE REPLACED IN LIKE KIND TO THE ORIGINAL
FEATURES AND TO THE APPROVAL OF THE CONTRACTING OFFICER.
COORDINATE WITH CONTRACTING OFFICER.
11. CONTRACTOR IS RESPONSIBLE FOR MOWING AND MAINTAINING ALL AREAS
WITHIN THE PROJECT LIMITS. FROM NOTICE-TO-PROCEED DATE THROUGH
THE DURATION OF THE PROJECT. MOW TO A MAXIMUM AVERAGE HEIGHT
OF 3-INCHES FOR SPRING/SUMMER MAINTENANCE AND 6-INCHES FOR
FALL/WINTER MAINTENANCE.
12. EROSION CONTROL DEVICES MUST BE USED FOR THE STAGING AREA AND
ANY MATERIAL STOCK PILES WHEN NECESSARY TO CONTROL EROSION AND
STORM WATER RUNOFF, IN ACCORDANCE WITH ALL FEDERAL, STATE, AND
LOCAL REGULATIONS.
ACCESS AND SAFETY NOTES:
1. THE GENERAL CONTRACTOR'S WORKING HOURS AND ACCESS TO THE SITE
IS FROM 0600 - 1800 LOCAL TIME, MONDAY THRU FRIDAY, EXCEPT ON
FEDERAL HOLIDAYS OR ASSOCIATED MILITARY DOWN DAYS.
2. CONTRACTOR MUST PROVIDE AND INSTALL A PROFESSIONALLY PAINTED
SIGN, MEETING CONTRACTING OFFICER APPROVAL, AT THE CONSTRUCTION
ENTRANCE TO DIRECT MATERIAL SUPPLIERS AND EMPLOYEES TO THE
CONSTRUCTION SITE. CONTRACTOR MUST PROVIDE A MINIMUM NOTICE OF
48 HOURS TO THE CONTRACTING OFFICER REGARDING OVERSIZED OR
CONSTRUCTION DELIVERIES TO THE COMMERCIAL TRUCK GATE PRIOR TO
THOSE DELIVERIES. DELIVERIES MUST BE SCHEDULED MONDAY - FRIDAY,
0600 TO 1800.PAPERWORK VIA THE CONTRACTING OFFICER.
3. EXISTING BASE ROADS USED AS HAUL ROADS MUST BE MAINTAINED SUCH
THAT UNOBSTRUCTED ACCESS WILL BE PROVIDED AT ALL TIMES FROM THE
ROAD TO THE STAGING AREA AND FROM THE STAGING AREA TO THE WORK
SITE AND FACILITATE GOVERNMENT ACCESS TO THE BASE AT ALL TIMES.
THE MAINTENANCE OF HAUL ROADS MUST BE THE RESPONSIBILITY OF THE
CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNMENT. THE HAUL
ROAD LOCATIONS MUST BE AS INDICATED ON THE DRAWINGS AND
APPROVED BY THE CONTRACTING OFFICER. CONTRACTOR MUST
IMMEDIATELY CLEAN ANY DEBRIS DEPOSITED ONTO THE SITE, ROADS, ETC
FROM CONTRACTOR'S EQUIPMENT OR OPERATIONS. MATERIAL DROPPED
WITHIN THESE AREAS MUST BE CONTINUOUSLY REMOVED BY SURFACE
SWEEPERS OR OTHER APPROVED METHODS DURING WORKING HOURS.
CONTRACTOR TO MAINTAIN ONE FULLY OPERATIONAL STREET
SWEEPER/VAC TRUCK ON SITE AT ALL TIMES.
4. CONTRACTOR MUST COORDINATE ACTIVITIES THROUGHOUT THE PROJECT
IN A MANNER THAT ALLOWS EMERGENCY ACCESS TO ALL EXISTING
ROADWAYS AT ALL TIMES WITHOUT DELAYS TO EMERGENCY VEHICLE'S
RESPONSE TIME.
5. CONTRACTOR MUST COORDINATE WITH CONTRACTING OFFICER
CONCERNING ANY GOVERNMENT-OWNED EQUIPMENT REQUIRING
RELOCATION TO COMPLETE PROJECT WORK.
6. CONTRACTOR MUST SUBMIT STAGING AND LAYDOWN AREA LOCATION TO
COR PRIOR TO CONSTRUCTION.
7. ALL AREAS DISTURBED BY ANY CONSTRUCTION ACTIVITIES INCLUDING
BORROW AREAS, STOCKPILE AREAS, MATERIAL LAYDOWN , EQUIPMENT
PARKING, CONTRACTOR PARKING, BATCH PLANTS, EARTHWORK ACTIVITIES,
UTILITY TRENCHING, OVERHEAD UTILITY WORK, ETC MUST BE RESTORED
TO EXISTING CONDITIONS. ALL AREAS NOT DESIGNATED FOR PAVEMENT
OR GRAVEL SURFACING MUST BE COVERED WITH A MINIMUM 4-INCHES OF
TOPSOIL, SEEDED, AND IRRIGATED/MAINTAINED FOR A MINIMUM OF 12
MONTHS OR UNTIL 95% COVERAGE OF GROUND COVER PER THE
SPECIFICATIONS.
8. CONTRACTOR MUST PROVIDE ALL NECESSARY WATER AND TOILET
FACILITIES FOR HIS WORKERS WITHIN THE CONSTRUCTION ZONE.
CONTRACTOR WORKERS MUST NOT USE GOVERNMENT FACILITIES UNLESS
SPECIFICALLY INDICATED OTHERWISE. LOCATIONS OF FACILITIES MUST BE
COORDINATED WITH CONTRACTING OFFICER.
9. IF ANY EMERGENCY ROUTES REQUIRE CLOSURE DUE TO CONSTRUCTION
ACTIVITIES, CONTRACTOR MUST NOTIFY THE CONTRACTING OFFICER,
POLICE, LOCAL FIRE AUTHORITY, AND ALL OTHER EMERGENCY SERVICES
OF THE CLOSURE AT LEAST 21 DAYS IN ADVANCE FOR APPROVAL. SEE
NOTE 6 UNDER TRAFFIC CONTROL.
COORDINATION AND COMMUNICATION
DURING CONSTRUCTION:
1. CONTRACTOR MUST APPOINT A PROJECT MANAGER AND CONSTRUCTION
SUPERINTENDENT, SUBJECT TO THE APPROVAL OF THE CONTRACTING
OFFICER, WHO MUST BE PRESENT ON THE CONSTRUCTION SITE AT ALL
TIMES DURING WORKING HOURS WHILE JOB IS IN PROGRESS. THE
PROJECT MANAGER MUST BE DESIGNATED THE RESPONSIBLE
CONTRACTOR'S REPRESENTATIVE WHO MUST BE AVAILABLE ON A 24-HOUR
BASIS. WHEN THE CONTRACTOR'S REPRESENTATIVE IS NOT AVAILABLE ON
THE CONSTRUCTION SITE, AN ALTERNATE REPRESENTATIVE MUST BE
PROVIDED. CONTRACTOR MUST PROVIDE NAMES AND CONTACT
INFORMATION OF REPRESENTATIVES TO THE CONTRACTING OFFICER
PRIOR TO THE START OF CONSTRUCTION ACTIVITIES.
2. CONTRACTOR MUST BE RESPONSIBLE FOR MAINTAINING CONSTANT
COORDINATION BETWEEN ANY SUBCONTRACTORS AND THE CONTRACTING
OFFICER. ALL CONSTRUCTION ACTIVITIES PLANNED BY THE CONTRACTOR
MUST BE REVIEWED AND APPROVED BY THE CONTRACTING OFFICER.
3. CONTRACTOR MUST CALL 911 IN CASE OF AN EMERGENCY.
TRAFFIC CONTROL:
1. PRIOR TO CONSTRUCTION, THE CONTRACTOR MUST CORDON OFF THE
WORK AREAS BY USING BARRICADES AND FENCING AS INDICATED ON THE
CONSTRUCTION HAUL ROUTE PLAN AND AS APPROVED BY THE
CONTRACTING OFFICER.
2. ALL CONSTRUCTION EQUIPMENT AND CONTRACTOR CONSTRUCTION
VEHICLES MUST BE MARKED WITH COMPANY PAINTED DESIGNS, INSIGNIAS
OR OTHER COMPANY MARKINGS, WHICH ARE CLEARLY VISIBLE.
3. CONSTRUCTION EQUIPMENT MUST HAVE AUTOMATIC SIGNALING DEVICES
TO SOUND AN ALARM WHEN MOVING IN REVERSE.
4. ONLY RUBBER-TIRED VEHICLES MUST BE ALLOWED ON EXISTING
PAVEMENT THAT IS TO REMAIN.
5. CONTRACTOR TO MAINTAIN ALTERNATIVE PEDESTRIAN ACCESS ROUTES
DURING CONSTRUCTION.
6. CONTRACTOR MUST PROVIDE A MINIMUM TWENTY-ONE (21) DAY NOTICE TO
DES MOINES RESERVE CENTER AND THE CONTRACTING OFFICER PRIOR TO
ANY REQUESTED ROAD CLOSURE. THE 21 DAY ADVANCE NOTICE DOES NOT
MEAN THE REQUEST WILL BE AUTOMATICALLY APPROVED. CONTRACTOR
MUST WORK WITH COR TO FINALIZE DATES IF THE BASE HAS CONFLICTS
WITH OTHER ACTIVITIES.
7. D/B CONTRACTOR MUST OBTAIN ANY TRAFFIC CLOSURE PERMIT WITHIN
E ARMY POST ROAD R/W WITH CITY OF DES MOINES OFFICIAL.
EXCAVATION AND TRENCHES:
1. CONTRACTOR MUST COMPLY WITH THE MOST CURRENT EDITION OF OSHA
REGULATIONS, THE STATE OF IOWA LAWS CONCERNING EXCAVATION, AND
USACE EM 385-1-1 SAFETY AND HEALTH REQUIREMENT MANUAL.
2. OPEN TRENCHES AND EXCAVATIONS AT THE CONSTRUCTION SITE MUST BE
PROMINENTLY MARKED WITH ORANGE BARRICADES WITH FLASHING RED
LIGHTS ACCEPTABLE TO THE CONTRACTING OFFICER.
3. CONTRACTOR MUST PROVIDE A MINIMUM NOTICE OF 72 HOURS TO THE
CONTRACTING OFFICER AND ASSOCIATED UTILITY COMPANIES AND
AGENCIES BEFORE PROCEEDING WITH ANY EXCAVATION.
4. OPEN ONLY THOSE TRENCHES FOR WHICH MATERIAL IS ON-HAND AND
READY FOR PLACING THEREIN. AS SOON AS POSSIBLE AFTER THE
MATERIAL HAS BEEN PLACED AND WORK APPROVED, BACKFILL AND
COMPACT TRENCHES AS SPECIFIED, REPORT COMPACTION TESTING
RESULTS TO CONTRACTING OFFICER.
5. DEWATERING OF UTILITY TRENCHES AND OTHER EXCAVATIONS MAY BE
REQUIRED.
6. STRUCTURES AND UTILITIES TO BE REMOVED MUST BE BACKFILLED IN
ACCORDANCE WITH THE SPECIFICATIONS.
7. ALL TOPSOIL MUST BE STRIPPED FROM ALL AREAS WITHIN THE LIMITS OF
CONSTRUCTION AND STOCKPILED FOR LATER USE IN THE UPPER 4 INCHES
OF FINISHED GRADE TO PROVIDE A SUITABLE SOD BED. THE CONTRACTOR
MUST RECEIVE APPROVAL FROM THE CONTRACTING OFFICER FOR
TOPSOIL STOCKPILE LOCATIONS.
8. ALL WORK ADJACENT TO OR ON EXISTING ROADWAY MUST COMPLY WITH
CURRENT IOWA DEPARTMENT OF TRANSPORTATION (IOWADOT)
STANDARDS FOR TRAFFIC CONTROL AND SAFETY. ALL WORK IN AND
ADJACENT TO STREETS OR ROADS MUST BE COORDINATED WITH
CONTRACTING OFFICER. THE CONTRACTOR MUST PROVIDE THE
CONTRACTING OFFICER WITH A ONE-WEEK ADVANCE NOTICE PRIOR TO
BEGINNING OF WORK ADJACENT TO BASE ROADWAYS. NO WORK ADJACENT
TO OR ON EXISTING ROADS MUST BE INITIATED WITHOUT PRIOR APPROVAL
FROM THE CONTRACTING OFFICER.
C-003
G
EN
ER
AL
C O
N
ST
R U
C
TI
O N
N O
TE
S
W
2Q R
R
_C F_
Pl an s-
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 20
P
M
K
H
F
D
B
TE
TR
A
TE
C H
, I N
C
U S
H W
Y
Lo ui sv ille
, K Y
Ph on e
(5
) 5
-5
Fa x (5
) 5
-5 w w w .te tra te ch .c om
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
U S
AR
M
Y R
ES
ER
VE
, 2
E
A R
M Y
PO
ST
R D
D
ES
M
O
IN
ES
, I
A
LO
U
IS
VI
LL
E
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
D .R
IC
H
TE
R
J
U N
E
D
ES
M
O
IN
ES
A
R M
Y R
ES
ER
VE
C
EN
TE
R D
/B R
FP
D
EV
EL
O
PM
EN
T
FO
R
A R
M Y
R
ES
ER
VE
C
EN
TE
R
B U
IL
D
IN
G
V
EH
IC
LE
M
AI
N
TE
N
AN
C
E
SH
O P
BU
IL
D
IN
G
P2
D
.M . L
EC
KI
E
M .S
O
SA
A.
C
AS
TI
LL
O
E.
M
AN
G
IW
A
/ A . D
U
EH
R
18 19
C
ER
TI
FI
ED
F
IN
AL
R
FP
S U
BM
IT
TA
L
OTHER SAFETY REQUIREMENTS:
1. CONTRACTOR MUST MAINTAIN SAFETY PRACTICES THAT CONFORM TO OCCUPATIONAL SAFETY AND
HEALTH ADMINISTRATION (OSHA) REGULATIONS AND USACE SAFETY MANUAL EM 385-1-1.
2. CONTRACTOR MUST MAINTAIN AT ALL TIMES ONE FIRE LANE FREE FROM OBSTRUCTION AND
MAINTAIN ACCESS TO AND THROUGH THE SITE, AND SURROUNDING ROADS AND STREETS.
3. CONTRACTOR MUST OBTAIN A BURN PERMIT FROM THE FIRE DEPARTMENT PRIOR TO PERFORMING
ANY WELDING ON SITE.
4. THE CONTRACTOR MUST PERFORM ON-SITE INSPECTIONS DAILY AND PRIOR TO LEAVING THE SITE
EACH DAY TO REMEDY ANY SAFETY CONCERNS IMMEDIATELY.
5. THERE MUST BE NO PERMANENT WASTE SITES ON RESERVE CENTER PROPERTY. ANY TEMPORARY WASTE AREA (10 DAYS OR LESS) MUST BE APPROVED BY THE CONTRACTING OFFICER AND MUST BE KEPT IN AN ORDERLY CONDITION. REMOVAL OF WASTE THAT IS NOT PROPERLY MAINTAINED IS
SUBJECT TO THE DIRECTION OF THE CONTRACTING OFFICER.
6. CONTRACTOR MUST COORDINATE THE RELOCATION AND SALVAGE OF ANY GOVERNMENT OWNED
EQUIPMENT WITH THE CONTRACTING OFFICER.
7. CONTRACTOR MUST MAKE NECESSARY PROVISIONS TO CONTROL/PREVENT DUST CAUSED BY
CONSTRUCTION ACTIVITIES TO A LIMIT ACCEPTABLE TO RESERVE CENTER OPERATIONS. THE
CONTRACTOR MUST CONTROL/PREVENT BLOWING DUST ON THE PROJECT SITE FROM ANY HAUL
ROUTE OR WORK AREA REGARDLESS OF SOURCE.
8. GASOLINE, DIESEL FUEL, OIL, AND HAZARDOUS WASTE RESULTING FROM CONTRACTOR'S
OPERATIONS OR ACTIVITIES MUST BE PROPERLY DISPOSED OF IN ACCORDANCE WITH THE
SPECIFICATIONS AND LOCAL REGULATORY REQUIREMENTS AND PROPERLY REMOVED FROM THE
PROJECT PROPERTY. IF HAZARDOUS MATERIALS ARE ENCOUNTERED OR UNCOVERED DURING
CONSTRUCTION ACTIVITIES, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING
OFFICER.
9. FAILURE TO COMPLY WITH DES MOINES RESERVE CENTER OPERATIONS AND THE CONTRACTING
OFFICER SAFETY REQUIREMENTS MUST RESULT IN THE SUSPENSION OF CONSTRUCTION
ACTIVITIES UNTIL ALL SAFETY CONCERNS ARE ADDRESSED BY THE CONTRACTOR TO THE
SATISFACTION OF THE CONTRACTING OFFICER.
10. ANY WORKERS AND EQUIPMENT NOT IN COMPLIANCE WITH SAFETY PLAN OR BASE OPERATIONS MUST IMMEDIATELY BE REMOVED FROM THE WORK AREA AND MUST NOT BE PERMITTED TO RETURN
THROUGHOUT THE REMAINDER OF THE PROJECT.
11. ALL TEMPORARY CONSTRUCTION LIGHTING MUST BE COORDINATED WITH DES MOINES RESERVE
CENTER AND SECURITY FORCES FOR APPROVAL OF LOCATIONS, HEIGHT, AND DIRECTION.
12. PROVIDE KEY ACCESS TO ALL CONSTRUCTION GATES TO THE RESERVE CENTER FIRE DEPARTMENT
DURING CONSTRUCTION. COORDINATE ACCESS PADLOCKS AND KEYS WITH THE CONTRACTING
OFFICER.
13. SPILL RESPONSE PLAN: A SPILL IS DEFINED AS AN UNINTENTIONAL RELEASE OF A CHEMICAL TO THE ENVIRONMENT. THE SPILL RESPONSE PLAN MUST BE DEVELOPED BY THE CONTRACTOR AND MUST IDENTIFY THE EQUIPMENT, PROCEDURES, NOTIFICATION AND MANPOWER THAT WILL BE USED TO PREVENT OR MITIGATE A SPILL EVENT. THE CONTRACTOR MUST DEMONSTRATE THE ABILITY TO PERFORM EMERGENCY DUTIES INCLUDING PROVIDING A DETAILED LIST OF EQUIPMENT THAT WILL BE STORED ON SITE DURING CONSTRUCTION AND A LIST AND CORRESPONDING QUALIFICATION FOR
THE PERSONNEL THAT WILL BE ASSIGNED THE DUTY. THIS PLAN MUST BE SUBMITTED AND
APPROVED BY THE GOVERNMENT AND DES MOINES RESERVE CENTER PRIOR TO BEGINNING ANY
CONSTRUCTION OR SITE DISTURBANCE ACTIVITIES.
EROSION AND SEDIMENT CONTROL NOTES:
1. EROSION CONTROL MEASURES MUST BE IN PLACE PRIOR TO ANY DISTURBANCE.
2. EROSION AND SEDIMENT CONTROL DEVICES MUST BE USED FOR THE STAGING AREA AND ANY
MATERIAL STOCK PILES WHEN NECESSARY TO CONTROL EROSION AND STORM WATER RUNOFF.
3. LIMITS OF CONSTRUCTION IS DEFINED AS THOSE AREAS AFFECTED BY THE CONTRACTOR'S
OPERATIONS INVOLVING EXCAVATION, EMBANKMENT, AND FINAL GRADING REQUIRED TO COMPLETE
THE WORK IN ACCORDANCE WITH THE ELEVATIONS, GRADES, AND SECTIONS SHOWN IN THESE
DRAWINGS.
4. THE CONTRACTOR MUST SEED ALL DISTURBED AREAS WITHIN THE SITE LIMITS, INCLUDING ALL CUT AND FILL SECTIONS IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. CONTRACTOR MUST
MAINTAIN GRASS UNTIL A PERMANENT VEGETATION COVER HAS BEEN ESTABLISHED PRIOR TO
FINAL ACCEPTANCE OF THE PROJECT. ESTABLISHMENT OF A PERMANENT VEGETATION COVER
MUST INCLUDE: PLACEMENT OF TOPSOIL, APPLICATION OF FERTILIZER, PLANTING OF GRASS
SPECIES SELECTED, IRRIGATIONS AS REQUIRED, AND RAKING OR HAND FINISHING.
5. CONTRACTOR MUST UTILIZE BEST MANAGEMENT PRACTICES PLAN DETAILS SHOWN HEREIN.
6. CONTRACTORS STAGING AREA MUST BE RETURNED TO ORIGINAL CONDITIONS AS APPROVED BY
COR AT COMPLETION OF CONSTRUCTION.
7. CONTRACTOR MUST CONTROL DUST WITHIN THE CONSTRUCTION SITE TO MITIGATE BLOWING
MATERIAL ONTO ADJACENT AIRFIELD OPERATIONS AREAS BY WETTING SOILS OR OTHER MITIGATION
MEASURES.
8. ALL TEMPORARY SOIL EROSION AND SEDIMENT CONTROL MEASURES MUST BE REMOVED ONCE AN
AREA OF DISTURBANCE HAS BEEN STABILIZED.
PETROLEUM PRODUCTS:
1. ALL ON-SITE VEHICLES MUST BE MONITORED FOR PETROLEUM LEAKS AND MUST RECEIVE PROPER
PREVENTATIVE MAINTENANCE TO REDUCE THE CHANCE OF LEAKAGE. PETROLEUM PRODUCTS
MUST BE STORED IN TIGHTLY-SEALED CONTAINERS THAT ARE CLEARLY LABELED. ALL SPILLS MUST BE CLEANED UP IMMEDIATELY AFTER DISCOVERY. WASTE OIL AND OTHER PETROLEUM PRODUCTS
USED ON-SITE MUST BE APPLIED ACCORDINGLY TO THE MANUFACTURER RECOMMENDATIONS.
C-004
G
EN
ER
AL
C O
N
ST
R U
C
TI
O N
N O
TE
S
PLAN
NORTH
IOWA
G10VICINITY MAP
NTS
PLAN
NORTH
A10LOCATION MAP
SCALE: NTS
DES MOINES
W
2Q R
R
_C F_
Pl an s-
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 20
P
M
K
H
F
D
B
TE
TR
A
TE
C H
, I N
C
U S
H W
Y
Lo ui sv ille
, K Y
Ph on e
(5
) 5
-5
Fa x (5
) 5
-5 w w w .te tra te ch .c om
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
U S
AR
M
Y R
ES
ER
VE
, 2
E
A R
M Y
PO
ST
R D
D
ES
M
O
IN
ES
, I
A
LO
U
IS
VI
LL
E
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
D
ES
M
O
IN
ES
A
R M
Y R
ES
ER
VE
C
EN
TE
R D
/B R
FP
D
EV
EL
O
PM
EN
T
FO
R
A R
M Y
R
ES
ER
VE
C
EN
TE
R
B U
IL
D
IN
G
V
EH
IC
LE
M
AI
N
TE
N
AN
C
E
SH
O P
BU
IL
D
IN
G
P2
18 19
C
ER
TI
FI
ED
F
IN
AL
R
FP
S U
BM
IT
TA
L
NO SCALEH1 GEOTECHNICAL BORING LOCATION PLAN
NOTES:
1. THE SUBSURFACE GEOTECHNICAL INVESTIGATION WAS
PERFORMED BY BRAUN INTERTEC IN FEBRUARY 2024.
2. SEE APPENDIX TO THE SPECIFICATIONS FOR BORING LOGS AND
TEST DATA.
BORING LOCATION TABLE
NUMBER LATITUDE LONGITUDE
BORING
DEPTH (FT) DESCRIPTION
B-01 41.52590 -91.61329 10.0 ASPHALT
B-02 41.52518 -93.61280 10.0 ASPHALT
B-03 41.52461 -93.61285 10.0 ASPHALT
B-04 41.52549 -93.61198 10.0 ASPHALT
B-05 41.52505 -93.61222 10.0 ASPHALT
B-06 41.52465 -93.61197 10.0 ASPHALT
B-07 41.52606 -93.61315 25.0 TOPSOIL
B-08 41.52575 -93.61244 25.0 TOPSOIL
B-09 41.52482 -93.61322 25.0 ASPHALT
B-10 41.52469 -93.61295 25.0 ASPHALT
NO SCALEA1 BORING LOGS B-101
BO
R
IN
G
L O
C
AT
IO
N
P
LA
N A
N D
L O
G S
W
2Q R
R
_C F_
Pl an s-
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 20
P
M
K
H
F
D
B
TE
TR
A
TE
C H
, I N
C
U S
H W
Y
Lo ui sv ille
, K Y
Ph on e
(5
) 5
-5
Fa x (5
) 5
-5 w w w .te tra te ch .c om
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
U S
AR
M
Y R
ES
ER
VE
, 2
E
A R
M Y
PO
ST
R D
D
ES
M
O
IN
ES
, I
A
LO
U
IS
V…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .