This document appears to be a Request for Proposal (RFP) for the reconfiguration and modernization of the LTC Luis E. Martinez Army Reserve Center (ARC) in Perrine, Florida. The project includes the alteration and renovation of the existing 78,625 square foot training building, construction of a new 19,363 square foot Area Maintenance Support Activity (AMSA) and Vehicle Maintenance Shop (VMS), and a new 50,747 square foot Organizational Storage Building. Supporting facilities such as land clearing, building demolition, paving, utilities, and security measures are also included. The solicitation will be issued as a single Firm-Fixed-Price contract with a NAICS code of 236220 and a business size standard of $45 million. The procurement will be conducted as an unrestricted, full and open competition using a Best Value Trade-Off source selection process. Proposals will be evaluated on past performance, technical factors, and price. The government estimates the construction magnitude to be between $25 million and $100 million.

View the file

Other files

Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M a rs h a ll

S t

N E

M in n e a p o lis

, M N

-1

R S

P A r c h it e c t s

L td

P N

P

F Y

.6

.7

.6

.7 f a x rs p a rc h .c o m

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED BY

ME OR UNDER MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED ARCHITECT UNDER

THE LAWS OF THE STATE OF MINNESOTA.

DATE SIGNED

LICENSE NUMBER

NAME

CERTIFICATION

G-002

S H

E E

T I

N D

E X

P E

R R

IN

E

F

L O

R

ID

A L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y

T G

R U

N D

T N

E R

N C

H R

IS

T

IA

N

S O

N

D N

O R

B A

C K

C B

R O

S S

M A

N

F

E B

R U

A R

Y

C E

R T

IF

IE

D F

IN

A

L

A R

M Y

R E

S E

R V

E C

E N

T E

R A

N D

A M

S A

C A

R -7

F Y

11902

26 APRIL 2024

David C. Norback

CONTINUED ON G-003

SHEET INDEX - VOLUME 1

NO. DESCRIPTION

A-203 TRAINING BUILDING - EXTERIOR ELEVATIONS

A-204 TRAINING BUILDING - EXTERIOR ELEVATIONS

A-205 TRAINING BUILDING - EXTERIOR ELEVATIONS

A-211 ORGANIZATIONAL STORAGE - EXTERIOR ELEVATIONS - OVERALL

A-212 ORGANIZATIONAL STORAGE - EXTERIOR ELEVATIONS

A-213 ORGANIZATIONAL STORAGE - EXTERIOR ELEVATIONS

A-214 ORGANIZATIONAL STORAGE - EXTERIOR ELEVATIONS

A-215 ORGANIZATIONAL STORAGE - EXTERIOR ELEVATIONS

A-221 AMSA/VMS - EXTERIOR ELEVATIONS

A-222 AMSA/VMS - EXTERIOR ELEVATIONS

A-301 TRAINING BUILDING - BUILDING SECTIONS

A-302 TRAINING BUILDING - WALL SECTIONS

A-303 TRAINING BUILDING - WALL SECTIONS

A-311 ORGANIZATIONAL STORAGE - BUILDING SECTIONS

A-312 ORGANIZATIONAL STORAGE - WALL SECTIONS

A-313 ORGANIZATIONAL STORAGE BUILDING - WALL SECTION - PEMB STRUCTURE CLEARENCES

A-321 AMSA/VMS - BUILDING SECTIONS

A-322 AMSA/VMS -WALL SECTIONS

A-323 AMSA/VMS - WALL SECTIONS

A-324 AMSA/VMS -WALL SECTIONS

A-400 TOILET AND LOCKER ROOM ACCESSORY ELEVATIONS AND DETAILS

A-401 TRAINING BUILDING - ENLARGED TOILET/LOCKER/SHOWER PLANS

A-402 TRAINING BUILDING - ENLARGED PLANS

A-403 TRAINING BUILDING - INTERIOR ELEVATIONS - RESTROOMS

A-404 TRAINING BUILDING - INTERIOR ELEVATIONS - LOBBY

A-405 TRAINING BUILDING - INTERIOR ELEVATIONS - MEDICAL ROOMS

A-406 TRAINING BUILDING - INTERIOR ELEVATIONS - BREAK ROOM, MAIL, ADMIN SUPPORT

A-407 TRAINING BUILDING - INTERIOR ELEVATIONS - ASSEMBLY HALL

A-408 TRAINING BUILDING - ENLARGED TOILET PLAN/ELEVATIONS

A-409 TRAINING CENTER - INTERIOR ELEVATIONS

A-410 ORGANIZATIONAL STORAGE - ENLARGED PLANS

A-411 ORGANIZATIONAL STORAGE - ENLARGED PLANS AND INTERIOR ELEVATIONS

A-420 AMSA/VMS - ENLARGED PLANS

A-421 AMSA/VMS - ENLARGED PLANS

A-422 AMSA/VMS - INTERIOR ELEVATIONS

A-501 EXTERIOR DETAILS - ROOF

A-502 EXTERIOR DETAILS - ROOF

A-503 EXTERIOR DETAILS - ROOF

A-504 EXTERIOR DETAILS - WALL

A-505 EXTERIOR DETAILS - WALL

A-506 EXTERIOR DETAILS - WALL

A-512 TRAINING BUILDING - EXTERIOR DETAILS - OPTION

A-513 TRAINING BUILDING - EXTERIOR DETAILS - EIFS/MWP BAND

A-514 TRAINING BUILDING - EXTERIOR DETAILS

A-515 PARACHUTE TOWER EXISTING CONDITIONS

A-520 EXTERIOR DETAILS - CURTAIN WALL

A-521 EXTERIOR DETAILS - CURTAIN WALL/WINDOW

A-522 EXTERIOR DETAILS - WINDOW AND TRANSLUCENT PANEL

A-523 EXTERIOR DETAILS - DOOR

A-524 EXTERIOR DETAILS - OVERHEAD COILING DOOR

A-525 EXTERIOR DETAILS - DOOR

A-526 EXTERIOR DETAILS - OPENING DETAILS

A-527 EXTERIOR DETAILS

A-530 SHIPS LADDER / ROOF LADDER SECTIONS AND DETAILS

A-531 ROOF LADDER AND SATS CANOPY SECTIONS AND DETAILS

A-540 PARTITION TYPES

A-541 INTERIOR DETAILS - PARTITION

A-542 INTERIOR DETAILS - CEILING

A-543 INTERIOR DETAILS - DOOR/WINDOW

A-544 INTERIOR DETAIL - DOOR/WINDOW

A-545 INTERIOR DETAILS - PARTITION - PEMB

A-550 INTERIOR DETAILS

A-551 PLAQUE MOUNTING AND LOBBY WOOD PANEL DETAILS

A-552 INTERIOR DETAILS - FLOOR

A-553 INTERIOR DETAILS - CASEWORK

A-554 INTERIOR DETAILS - CASEWORK

A-555 INTERIOR DETAILS - CAGING

A-601 CW TYPES, DOOR AND FRAME TYPES

A-602 DOOR SCHEDULE

A-603 DOOR SCHEDULE

A-810 ORGANIZATIONAL STORAGE - AIR BARRIER SYSTEM PLAN

SHEET INDEX - VOLUME 1

NO. DESCRIPTION

L-501 LANDSCAPE DETAILS

STRUCTURAL

S-001 GENERAL STRUCTURAL NOTES

S-101 TRAINING BUILDING - FOUNDATION PLAN - OVERALL

S-102 TRAINING BUILDING - FOUNDATION PLAN - AREA A

S-103 TRAINING BUILDING - FOUNDATION PLAN - AREA B

S-104 TRAINING BUILDING - FOUNDATION PLAN - AREA C

S-105 TRAINING BUILDING - FOUNDATION PLAN - AREA D

S-106 TRAINING BUILDING - FOUNDATION PLAN - AREA E

S-107 TRAINING BUILDING - FOUNDATION PLAN - AREA F

S-111 ORGANIZATIONAL STORAGE - FOUNDATION PLAN - OVERALL

S-112 ORGANIZATIONAL STORAGE - FOUNDATION PLAN - AREA A

S-113 ORGANIZATIONAL STORAGE - FOUNDATION PLAN - AREA B

S-114 ORGANIZATIONAL STORAGE - FOUNDATION PLAN - AREA C

S-121 AMSA/VMS - FOUNDATION PLAN - OVERALL

S-122 AMSA/VMS - FOUNDATION PLAN - AREA A

S-123 AMSA/VMS - FOUNDATION PLAN - AREA B

S-161 TRAINING BUILDING - ROOF FRAMING PLAN - OVERALL

S-162 TRAINING BUILDING - ROOF FRAMING PLAN - AREA A

S-163 TRAINING BUILDING - ROOF FRAMING PLAN - AREA B

S-164 TRAINING BUILDING - ROOF FRAMING PLAN - AREA C

S-165 TRAINING BUILDING - ROOF FRAMING PLAN - AREA D

S-166 TRAINING BUILDING - ROOF FRAMING PLAN - AREA E

S-167 TRAINING BUILDING - ROOF FRAMING PLAN - AREA F

S-171 ORGANIZATIONAL STORAGE - ROOF FRAMING CONCEPTUAL PLAN - OVERALL

S-172 ORGANIZATIONAL STORAGE - ROOF FRAMING CONCEPTUAL PLAN - AREA A

S-173 ORGANIZATIONAL STORAGE - ROOF FRAMING CONCEPTUAL PLAN - AREA B

S-174 ORGANIZATIONAL STORAGE - ROOF FRAMING CONCEPTUAL PLAN - AREA C

S-181 AMSA/VMS - ROOF FRAMING PLAN - OVERALL

S-182 AMSA/VMS - ROOF FRAMING PLAN - AREA A

S-183 AMSA/VMS - ROOF FRAMING PLAN - AREA B

S-201 TRAINING BUILDING - WALL ELEVATIONS

S-220 AMSA/VMS - WALL ELEVATION KEYPLAN

S-221 AMSA/VMS - WALL ELEVATIONS

S-222 AMSA/VMS - WALL ELEVATIONS

S-223 AMSA/VMS - WALL ELEVATIONS

S-401 TRAINING BUILDING - PARTIAL PLAN AT EXIST PC PLANK

S-411 ORGANIZATIONAL STORAGE - ENLARGED PLANS

S-421 AMSA/VMS - ENLARGED PLANS

S-422 AMSA/VMS - ENLARGED PLANS

S-423 AMSA/VMS - BRIDGE CRANE RUNWAY BEAM FRAMING PLAN

S-501 FOUNDATION DETAILS

S-502 FOUNDATION DETAILS

S-503 FOUNDATION DETAILS

S-504 ARMS VAULT DETAILS

S-505 FOUNDATION DETAILS

S-506 FOUNDATION DETAILS

S-507 FOUNDATION DETAILS

S-521 FRAMING DETAILS

S-522 FRAMING DETAILS

S-523 FRAMING DETAILS

S-524 FRAMING DETAILS

S-525 FRAMING DETAILS

S-531 TYPICAL MASONRY DETAILS

S-532 CONCRETE WALL DETAILS

S-601 SCHEDULES

S-621 AMSA/VMS - JOIST AND ROOF UPLIFT WIND PRESSURES

ARCHITECTURAL

AS101 WASH PLATFORM - OPTION 'F'

AS102 BI-LEVEL LOADING RAMP - OPTION K - PLANS, SECTIONS, AND DETAILS

AS103 BI-LEVEL LOADING RAMP - OPTION K - DETAILS

AS104 MONUMENT SIGN DETAILS

AD101 TRAINING BUILDING - DEMOLITION PLAN - OVERALL

AD102 TRAINING BUILDING - DEMOLITION PLAN - AREA A

AD103 TRAINING BUILDING - DEMOLITION PLAN - AREA B

AD104 TRAINING BUILDING - DEMOLITION PLAN - AREA C

AD105 TRAINING BUILDING - DEMOLITION PLAN - AREA D

AD106 TRAINING BUILDING - DEMOLITION PLAN - AREA E

AD107 TRAINING BUILDING - DEMOLITION PLAN - AREA F

AD110 TRAINING BUILDING - DEMOLITION ROOF PLAN

AD121 EXISTING OMS DEMOLITION

AD122 EXISTING WASH PLATFORM DEMOLITION

AD123 FPL BUILDING DEMOLITION

AD201 TRAINING BUILDING - DEMOLITION EXTERIOR ELEVATIONS

AD501 DEMOLITION DETAILS

A-101 TRAINING BUILDING - OVERALL FLOOR PLAN

A-102 TRAINING BUILDING - FLOOR PLAN - AREA A

A-103 TRAINING BUILDING - FLOOR PLAN - AREA B

A-104 TRAINING BUILDING - FLOOR PLAN - AREA C

A-105 TRAINING BUILDING - FLOOR PLAN - AREA D

A-106 TRAINING BUILDING - FLOOR PLAN - AREA E

A-107 TRAINING BUILDING - FLOOR PLAN - AREA F

A-110 ORGANIZATIONAL STORAGE - UNDERSLAB RADON PLAN

A-111 ORGANIZATIONAL STORAGE - OVERALL FLOOR PLAN

A-112 ORGANIZATIONAL STORAGE - FLOOR PLAN - AREA A

A-113 ORGANIZATIONAL STORAGE - FLOOR PLAN - AREA B

A-114 ORGANIZATIONAL STORAGE - FLOOR PLAN - OPTION E

A-120 AMSA/VMS - UNDERSLAB RADON PLAN

A-121 AMSA/VMS - FLOOR PLAN - OVERALL

A-122 AMSA/VMS - FLOOR PLAN - AREA A

A-123 AMSA/VMS - FLOOR PLAN - AREA B

A-131 TRAINING BUILDING - REFLECTED CEILING PLAN - OVERALL

A-132 TRAINING BUILDING - REFLECTED CEILING PLAN - AREA A

A-133 TRAINING BUILDING - REFLECTED CEILING PLAN - AREA B

A-134 TRAINING BUILDING - REFLECTED CEILING PLAN - AREA C

A-135 TRAINING BUILDING - REFLECTED CEILING PLAN - AREA D

A-136 TRAINING BUILDING - REFLECTED CEILING PLAN - AREA E

A-137 TRAINING BUILDING - REFLECTED CEILING PLAN - AREA F

A-141 ORGANIZATIONAL STORAGE - REFLECTED CEILING PLAN - OVERALL

A-142 ORGANIZATIONAL STORAGE - REFLECTED CEILING PLAN - AREA A

A-143 ORGANIZATIONAL STORAGE - REFLECTED CEILING PLAN - AREA B

A-144 ORGANIZATIONAL STORAGE - REFLECTED CEILING PLAN - OPTION E

A-151 AMSA/VMS - REFLECTED CEILING PLAN - OVERALL

A-152 AMSA/VMS - REFLECTED CEILING PLAN - AREA A

A-153 AMSA/VMS - REFLECTED CEILING PLAN - AREA B

A-161 TRAINING BUILDING - ROOF PLAN

A-171 ORGANIZATIONAL STORAGE - ROOF PLAN

A-172 ORGANIZATIONAL STORAGE - ROOF PLAN - OPTION E

A-181 AMSA/VMS - ROOF PLAN

A-201 TRAINING BUILDING - EXTERIOR ELEVATIONS - OVERALL

A-202 TRAINING BUILDING - EXTERIOR ELEVATIONS

SHEET INDEX - VOLUME 1

NO. DESCRIPTION

GENERAL

G-001 COVER SHEET

G-002 SHEET INDEX

G-003 SHEET INDEX

G-004 ABBREVIATIONS AND SYMBOLS

G-010 CODE REVIEW SUMMARY - FOR REFERENCE ONLY

G-011 CODE REVIEW SUMMARY - FOR REFERENCE ONLY

G-101 TRAINING BUILDING - FIRE PROTECTION / LIFE SAFETY PLAN - OVERALL

G-102 TRAINING BUILDING - FIRE PROTECTION / LIFE SAFETY PLAN

G-103 TRAINING BUILDING - FIRE PROTECTION / LIFE SAFETY PLAN

G-111 ORGANIZATIONAL STORAGE - FIRE PROTECTION/LIFE SAFETY PLAN

G-112 ORGANIZATIONAL STORAGE - FIRE PROTECTION/LIFE SAFETY PLAN - WITH OPTION E

G-121 AMSA/VMS - FIRE PROTECTION/LIFE SAFETY PLAN

G-131 CODE COMPLIANCE SITE PLAN

G-200 SITE - PHASING PLAN

G-201 TRAINING BUILDING - PHASING PLAN - DEMOLITION

G-202 TRAINING BUILDING - PHASING PLAN

GR100 EXISTING SITE AERIAL PHOTO

GC101 EROSION CONTROL PLAN

GC102 EROSION CONTROL PLAN

GC103 EROSION CONTROL PLAN

GC501 EROSION CONTROL DETAILS

GC502 EROSION CONTROL DETAILS

SURVEY

V-001 BOUNDARY AND TOPOGRAPHIC SURVEY

V-002 OVERALL BOUNDARY AND TOPOGRAPHIC SURVEY

V-003 OVERALL BOUNDARY AND TOPOGRAPHIC SURVEY

V-004 BOUNDARY AND TOPOGRAPHIC SURVEY

V-005 BOUNDARY AND TOPOGRAPHIC SURVEY

V-006 BOUNDARY AND TOPOGRAPHIC SURVEY

GEOTECHNICAL

B101 BORING LOCATIONS

B102 BORING LOGS

B103 BORING LOGS

B104 BORING LOGS

B105 BORING LOGS

B106 TEST BORING FENCE RECORD

CIVIL

CD101 SITE DEMOLITION PLAN

CD102 SITE DEMOLITION PLAN

CD103 SITE DEMOLITION PLAN

CD105 ENTRANCE DEMOLITION PLAN

CD106 MISCELLANEOUS DEMOLITION AS-BUILTS

CD107 SITE DEMOLITION PLAN PICTURES

CD108 SITE DEMOLITION PLAN AS BUILTS

CS100 OVERALL SITE PLAN LAYOUT

CS101 SITE PLAN

CS102 SITE PLAN

CS103 SITE PLAN

CS104 SITE PLAN

CS105 SITE PLAN

CS301 HORIZONTAL CONTROL PLAN - AREA 'A'

CS302 HORIZONTAL CONTROL PLAN - AREA 'B'

CS303 HORIZONTAL CONTROL PLAN - AREA 'C'

CS501 SITE DETAILS

CS502 SITE DETAILS

CS503 SITE DETAILS

CS504 SITE DETAILS

CS505 SITE DETAILS

CS506 SITE DETAILS

CS507 SITE DETAILS

CS508 SITE DETAILS

CG101 SITE GRADING AND DRAINAGE PLAN - AREA 'A'

CG102 SITE GRADING AND DRAINAGE PLAN - AREA 'B'

CG103 SITE GRADING AND DRAINAGE PLAN - AREA 'C'

CG201A STORM SEWER PROFILES

CG201B STORM SEWER PROFILES

CG201C STORM SEWER PROFILES

CG201D STORM SEWER PROFILES

CG501 GRADING AND DRAINAGE DETAILS

CG502 GRADING AND DRAINAGE DETAILS

CP101 SITE PAVING PLAN

CP105 ENTRANCE PAVING PLAN

CP501 SITE PAVING DETAILS

CP502 PAVING DETAILS

CP503 PAVING DETAILS

CP504 PAVING DETAILS

CP505 PAVING DETAILS

CU101 SITE UTILITY PLAN - AREA 'A'

CU102 SITE UTILITY PLAN - AREA 'B'

CU103 SITE UTILITY PLAN - AREA 'C'

CU104 PERMIT MATRIX

CU201 SANITARY SEWER PROFILES

CU202 SANITARY SEWER PROFILES

CU501 UTILITY DETAILS

CU502 UTILITY DETAILS

CU503 UTILITY DETAILS

CU800 COVER SHEET, LOCATION MAP & DRAWING LIST

CU801 NOTES

CU802 SITE DEMOLITION PLAN - AREA 'D'

CU803 SITE PAVING PLAN

CU810 SITE UTILITY PLAN - OVERALL

CU820 SITE UTILITY PLAN - AREA 'D'

CU821 SITE UTILITY PLAN - AREA 'D'

CU822 SITE UTILITY PLAN - AREA 'D'

CU830 DETAILS

CU831 NOT USED - SHEET OMITTED - AMENDMENT 0007

CU832 NOT USED - SHEET OMITTED - AMENDMENT 0007

CU833 NOT USED - SHEET OMITTED - AMENDMENT 0007

CU834 NOT USED - SHEET OMITTED - AMENDMENT 0007

LANDSCAPE

L-001 LANDSCAPE NOTES AND SYMBOLS

L-101 OVERALL LANDSCAPE PLAN

L-102 LANDSCAPE PLAN - AREA A

L-103 LANDSCAPE PLAN - AREA B

L-104 ENLARGED LANDSCAPE PLAN B

L-105 LANDSCAPE PLAN - AREA C

L-106 LANDSCAPE PLAN - AREA D

L-107 LANDSCAPE PLAN - AREA E

L-108 LANDSCAPE PLAN - AREA F

L-109 LANDSCAPE PLAN - AREA D - OPTION 'E'

A

M E

N D

M E

N T

/2

/2

A

M E

N D

M E

N T

/1

/2

1 1

2 2

11 JULY 2024

W

2Q R

R

_P la ns -0

ARIMS: 200A Disposition: Maintain for 15 yrs after construction.

W

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

2Q R

R

_P la ns -0

B A

S E

B

ID

L

IM

IT

S

A R

E A

B

ID

O P

T

IO

N

O8O14 O13 O12 O5 O3 O1

OA

OB

OC

OD

OE

OF

OM

OK

OJ

OL

OH

OG

O7 O6.2 O5.5 O4.5 O3.5 O2.5 O1.8O91011

5' - 9" 2' - 8"

6" DIA PVC PIPE

THROUGH ROOF

SEE FLOOR PLANS FOR

PARTITION TYPE

PIPE SLEEVE

(OPTIONAL)

CONCRETE SLAB

4" POURED CONCRETE BASE

CAPILLARY WATER BARRIER -

REFER TO S-100

VB-1, LAP AND TAPE TO PERIMETER OF

METAL DECK

8" 4' - 0" SQUARE 8"1

(8) #4 x 8'-0" @ 12" OC EACH

WAY CENTERED OVER PIT

1 1/2" x 18 GA TYPE B GALVANIZED METAL

DECK. PROVIDE SEALANT AT DECK LAP

JOINTS. TACK WELD TO FRAME, (2) EA SIDE

GALV. FRAME, L2x2x1/4 CONT TOP AND BOTTOM WITH L2x2x1/4 VERT AT EACH

CORNER AND EXPANDED METAL MESH

WELDED TO ANGLES ALL FOUR SIDES.

ANCHOR TO CONCRETE BASE WITH 1/2"

EXPANSION BOLT AT EACH CORNER.

CAPILLARY WATER BARRIER TO

CONTINUE UNDER THICKENED SLAB

TO PROVIDE CONTINUITY OF RADON

EXTRACTION

FOR THICKENED SLAB INFORMATION,

REFER TO STRUCT

SEE FOR TYP NOTES/5 A-110

3" NOM DIA PVC PIPE @ 4'-0"

OC, TYP

ARMS VAULT

138 SEE FOR TYP NOTES/5 A-110

CONCRETE OR CMU WALL,

SEE WALL SECTIONS FOR

WALL CONSTRUCTION

SLAB ON GRADE

3" NOM DIA PVC PIPE @ 4'-0"

OC, TYP

VB-1

CAPILLARY WATER BARRIER

6" DIA PVC PIPE THROUGH ROOF,

SEE GENERAL NOTES ON THIS

SHEET

4' - 0"

RADON PIT,

SEE 3/A-100

PROJECT

NORTH

TRUE

NORTH

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M a rs h a ll

S t

N E

M in n e a p o lis

-1

R S

P A r c h it e c t s

L td

P N

P

F Y

.6

.7

.6

.7 f a x rs p a rc h .c o m

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED BY

ME OR UNDER MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED ARCHITECT UNDER

THE LAWS OF THE STATE OF MINNESOTA.

DATE SIGNED

LICENSE NUMBER

NAME

CERTIFICATION

KEY PLAN - ORGANIZATIONAL

STORAGE BUILDING

BOPT E

A

A-110

O R

G A

N

IZ

A T

IO

N

A L S

T O

R A

G E

U

N D

E R

S L A

B R

A D

O N

P L A

N

P E

R R

IN

E

F

L O

R

ID

A L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y

T G

R U

N D

T N

E R

N C

H R

IS

T

IA

N

S O

N

D N

O R

B A

C K

C B

R O

S S

M A

N

F

E B

R U

A R

Y

C E

R T

IF

IE

D F

IN

A

L

A R

M Y

R E

S E

R V

E C

E N

T E

R A

N D

A M

S A

C A

R -7

F Y

11902

26 APRIL 2024

David C. Norback

1/16" = 1'-0"A-110

ORGANIZATIONAL STORAGE BUILDING - UNDERSLAB RADON PLAN1

1/2" = 1'-0"A-110

RADON EXTRACTION PIT SECTION2

1/2" = 1'-0"A-110

SECTION AT THICKENED SLAB3

1/2" = 1'-0"A-110

SECTION AT ARMS VAULT4

1/2" = 1'-0"A-110

SECTION AT FOUNDATION WALL5

1/2" = 1'-0"A-110

RADON EXTRACTION PIT PLAN6

KEYNOTE - UNDERFLOOR RADON

KEYNOTE DESCRIPTION

1 UNDERFLOOR RADON COLLECTION SUMP PIT WITH VENT

THROUGH ROOF - SEE 6/A-110

2 THROUGH WALL PIPE PENETRATION AT FOUNDATION WALL TO

PROVIDE CONTINUITY OF UNDER SLAB CAPILLARY WATER

BARRIER - SEE 5/A-110

3 THROUGH WALL PIPE PENETRATION AT ARMS VAULT FOUNDATION

WALL TO PROVIDE CONTINUITY OF UNDER SLAB CAPILLARY

WATER BARRIER - SEE 4/A-110

4 VENT AND PIPE LOCATION

GENERAL NOTES -

UNDERSLAB RADON PLAN

A. REFER TO STRUCTURAL DETAIL 1/S-505 FOR SLAB AND CAPILLARY WATER

BARRIER INFORMATION

B. VERTICAL VENT PIPING TO BE LABELED EVERY 10 FEET: "RADON VENT SYSTEM -

MAY CONTAIN HAZARDOUS LEVELS OF RADON"

C. AT THE RADON PIPE ROOF PENETRATION, ATTACH A LABEL READING: "SOIL GAS

VENT STACK. MAY CONTAIN HAZARDOUS LEVELS OF RADON. DO NOT PLACE AIR

INTAKE WITHIN 25 FEET.

D. PENETRATIONS OF THE SLAB TO BE SEALED. TO SEAL SLAB PENETRATION, TAPE

VAPOR BARRIER TO VERTICAL VENT PIPE AND SEAL ALL AROUND THE RADON VENT

PIPE AT TOP OF CONCRETE SLAB

0 8' 16' 32'

0 1' 2' 4'

0 1' 2' 4' 0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

A

M E

N D

M E

N T

/1

/2

11 JULY 2024

W

2Q R

R

_P la ns -0

A1

AF

AE

AD

AC.8

AC

AB

AA.2

AA

A7 A5 A4 A3 A2A6

" 2

4' - 0"

5' - 8"

TYP

PROJECT

NORTH

TRUE

NORTH

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M a rs h a ll

S t

N E

M in n e a p o lis

-1

R S

P A r c h it e c t s

L td

P N

P

F Y

.6

.7

.6

.7 f a x rs p a rc h .c o m

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED BY

ME OR UNDER MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED ARCHITECT UNDER

THE LAWS OF THE STATE OF MINNESOTA.

DATE SIGNED

LICENSE NUMBER

NAME

CERTIFICATION

KEY PLAN - AMSA/VMS

A

B

A-120

A M

S A

/V M

S

U N

D E

R S

L A

B R

A D

O N

P L A

N

P E

R R

IN

E

F

L O

R

ID

A L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y

T G

R U

N D

T N

E R

N C

H R

IS

T

IA

N

S O

N

D N

O R

B A

C K

C B

R O

S S

M A

N

F

E B

R U

A R

Y

C E

R T

IF

IE

D F

IN

A

L

A R

M Y

R E

S E

R V

E C

E N

T E

R A

N D

A M

S A

C A

R -7

F Y

11902

26 APRIL 2024

David C. Norback1/16" = 1'-0"A-120

AMSA/VMS - UNDERSLAB RADON PLAN1

KEYNOTE - UNDERFLOOR RADON

KEYNOTE DESCRIPTION

1 UNDERFLOOR RADON COLLECTION SUMP PIT WITH VENT

THROUGH ROOF - SEE 6/A-110

2 THROUGH WALL PIPE PENETRATION AT FOUNDATION WALL TO

PROVIDE CONTINUITY OF UNDER SLAB CAPILLARY WATER

BARRIER - SEE 5/A-110

3 THROUGH WALL PIPE PENETRATION AT ARMS VAULT FOUNDATION

WALL TO PROVIDE CONTINUITY OF UNDER SLAB CAPILLARY

WATER BARRIER - SEE 4/A-110

4 VENT AND PIPE LOCATION

GENERAL NOTES -

UNDERSLAB RADON PLAN

A. REFER TO STRUCTURAL DETAIL 1/S-505 FOR SLAB AND CAPILLARY WATER

BARRIER INFORMATION

B. VERTICAL VENT PIPING TO BE LABELED EVERY 10 FEET: "RADON VENT SYSTEM -

MAY CONTAIN HAZARDOUS LEVELS OF RADON"

C. AT THE RADON PIPE ROOF PENETRATION, ATTACH A LABEL READING: "SOIL GAS

VENT STACK. MAY CONTAIN HAZARDOUS LEVELS OF RADON. DO NOT PLACE AIR

INTAKE WITHIN 25 FEET.

D. PENETRATIONS OF THE SLAB TO BE SEALED. TO SEAL SLAB PENETRATION, TAPE

VAPOR BARRIER TO VERTICAL VENT PIPE AND SEAL ALL AROUND THE RADON VENT

PIPE AT TOP OF CONCRETE SLAB

0 8' 16' 32'

A

M E

N D

M E

N T

/2

/2

A

M E

N D

M E

N T

/1

/2

1 1

11 JULY 2024

W

2Q R

R

_P la ns -0

A-211

A-211

A-211

A-211

A-311

A-311

A-311

A-311

O8

2" / 12" 2" / 12"

O5 O3 O1

OA

OB

OC

OD

OE

OF

OM

OK

OJ

OL

OH

OG

O7 O6.2 O5.5 O4.5 O3.5 O2.5 O1.8

R

ID

G E

RIDGE

PROJECT

NORTH

TRUE

NORTH

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M a rs h a ll

S t

N E

M in n e a p o lis

-1

R S

P A r c h it e c t s

L td

P N

P

F Y

.6

.7

.6

.7 f a x rs p a rc h .c o m

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED BY

ME OR UNDER MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED ARCHITECT UNDER

THE LAWS OF THE STATE OF MINNESOTA.

DATE SIGNED

LICENSE NUMBER

NAME

CERTIFICATION

KEY PLAN - ORGANIZATIONAL

STORAGE BUILDING

BOPT E

A

A-171

O R

G A

N

IZ

A T

IO

N

A L S

T O

R A

G E

R

O O

F P

L A

N

P E

R R

IN

E

F

L O

R

ID

A L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y

T G

R U

N D

T N

E R

N C

H R

IS

T

IA

N

S O

N

D N

O R

B A

C K

C B

R O

S S

M A

N

F

E B

R U

A R

Y

C E

R T

IF

IE

D F

IN

A

L

A R

M Y

R E

S E

R V

E C

E N

T E

R A

N D

A M

S A

C A

R -7

F Y

11902

26 APRIL 2024

David C. Norback

1/16" = 1'-0"A-171

ORGANIZATIONAL STORAGE - ROOF PLAN1

KEYNOTES - ROOF PLAN

NO. DESCRIPTION

1 MOD BIT ROOF OVER RIGID INSUL, OVER SLOPED STRUCTURE.

SEE 1/A-502

2 EXISTING ROOF CURB. REF MECH. FOR EQUIPMENT REMOVAL,

SEE 7/A503

3 PROVIDE EXISTING SKYLIGHT CURB, SEE 7/A503

4 30" X 72" ROOF HATCH AT EXIST ROOF, SEE 5/501, SEE STRUC

FOR SUPPORT FRAME

5 ESS-1, SEE 1/A-132 & 2/A -153

6 ROOF LADDER FROM LOW TO HIGH ROOF, SEE 2/A530

7 EXIST ROOF DRAIN

9 PATCH EXIST METAL DECK AT EXIST OPNG (SEE STRUCT), AND

PROVIDE IN-FILL ROOFING ASSEMBLY TO MATCH EXIST ROOF

ASSEMBLY.

10 30" X 72" ROOF HATCH, SEE 6/502, SEE STRUC FOR SUPPORT

FRAME

11 EXHAUST FAN, SEE 2/A501

12 METAL CANOPY, SEE ELEVATIONS

13 WALKWAY PAD

14 TAPERED INSUL/CRICKET, ROOF SADDLE: 1"/FT BACKSLOPE,

FOR SURFACE SLOPE OF 1/2" /FT MIN

15 SCUPPER & DOWNSPOUT, SEE 1,2,4, & 6/A503

16 GRAVITY VENTILATOR, SEE 2/A501 (AT PEMB SSMR - CRICKET,

CURB, AND FLASHING PER MFR)

17 MAKE-UP AIR UNIT, SEE 2/A501 FOR CURBING AND 4/A501 FOR

CONDUIT AND PIPE FLASHING. SEE MECHANICAL

18 VENT PIPE, SEE 1/A501 (AT PEMB SSMR - FLASHING PER MFR)

19 EXIST MOD-BIT HIGH ROOF AT EXIST TOWER

20 EXIST SSMR; TRAPEZOIDAL RIB WITH MECHANICALLY SEAMED

SEAMS AND CONCEALED FASTENERS AND CLIPS. REFER TO

PHOTOS ON SHEET A-202

21 EXIST STEEL PARAPET LADDER. REFINISH WITH PNT-1

22 EXHAUST FAN ON EXISTING 30" X 30" CURB, SEE MECHANICAL

23 ROOF ACCESS LADDER, SEE 1/A531

24 CONDENSER UNIT, SEE 7/A502 FOR CURBING AND 4/A501 FOR

CONDUIT AND PIPE FLASHING. SEE MECHANICAL

25 EXISTING SCUPPER

26 GUARDRAIL, SEE 6/A501

27 EXHAUST FAN ON NEW 19" x 19" CURB, SEE 2/A501

28 EXHAUST FAN ON EXISTING 20" x 20" CURB, SEE MECH

30 MAKE-UP AIR UNIT ON EXISTING 78"x 35" CURB, SEE MECH

31 ROOFTOP FAN ON EXISTING 32"x 32" CURB, SEE MECH

32 ROOFTOP FAN ON EXISTING 24"x 24" CURB, SEE MECH

33 RADON PIPE AT PEMB SSMR, SEE A-110

34 MECHANICAL UNIT, SEE 3/A502 FOR CURBING AND 5/A502 FOR

CONDUIT AND PIPE FLASHING. SEE MECHANICAL

35 CONDENSING UNIT, SEE 4/A502 FOR CURBING AND 5/A502 FOR

CONDUIT AND PIPE FLASHING. SEE MECHANICAL

36 GRAVITY VENTILATOR, SEE 3/A502

37 EXHAUST FAN, SEE 3/A502

38 VENT PIPE, SEE 5/A502

39 ROOFTOP DUCTWORK, MOUNTING PER DUCT MFR, FLASH SIM

TO 1/A-501. SEE MECH.

40 EXISTING ROOF CAP CURB

41 PROVIDE 1" INSULATION AT SCUPPER. PROVIDE SLOPED

INSULATION AT 1/2" PER FT. PROVIDE CRICKETS AT SCUPPER.

42 RADON PIPE, SEE 2/A-502 AND A-120

GENERAL NOTES - ROOF PLAN

A. ROOF SYSTEM: PEMB STANDING SEAM ROOF PANEL WITH BATT

INSULATION WITH WEATHER BARRIER ON PEMB GIRTS.

B. FOR ROOF WIND UPLIFT DESIGN REQUIREMENTS, SEE STRUCTURAL

C. FOR ALL DECK BEARING ELEVATIONS, SEE STRUCTURAL

D. FOR DOWNSPOUT LOCATIONS, SEE EXTERIOR ELEVATIONS

E. COORDINATE THE LOCATION OF ALL MECHANICAL AND PLUMBING

ITEMS WITH MECHANICAL AND PLUMBING SHEETS

0 8' 16' 32'

A

M E

N D

M E

N T

/2

/2

A

M E

N D

M E

N T

/1

/2

11 JULY 2024

W

2Q R

R

_P la ns -0

A-311

O8O14 O13 O12

A-215

A-212

OM

OK

OJ

OL

OH

OG

O7

SIM

RIDGE

O91011

A-215

PROJECT

NORTH

TRUE

NORTH

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M a rs h a ll

S t

N E

M in n e a p o lis

-1

R S

P A r c h it e c t s

L td

P N

P

F Y

.6

.7

.6

.7 f a x rs p a rc h .c o m

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED BY

ME OR UNDER MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED ARCHITECT UNDER

THE LAWS OF THE STATE OF MINNESOTA.

DATE SIGNED

LICENSE NUMBER

NAME

CERTIFICATION

KEY PLAN - ORGANIZATIONAL

STORAGE BUILDING

BOPT E

A

A-172

O R

G A

N

IZ

A T

IO

N

A L S

T O

R A

G E

R

O O

F P

L A

N

O P

T

IO

N E

P E

R R

IN

E

F

L O

R

ID

A L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y

T G

R U

N D

T N

E R

N C

H R

IS

T

IA

N

S O

N

D N

O R

B A

C K

C B

R O

S S

M A

N

F

E B

R U

A R

Y

C E

R T

IF

IE

D F

IN

A

L

A R

M Y

R E

S E

R V

E C

E N

T E

R A

N D

A M

S A

C A

R -7

F Y

11902

26 APRIL 2024

David C. Norback

1/16" = 1'-0"A-172

ORGANIZATIONAL STORAGE - ROOF PLAN - OPTION E1

KEYNOTES - ROOF PLAN

NO. DESCRIPTION

1 MOD BIT ROOF OVER RIGID INSUL, OVER SLOPED STRUCTURE.

SEE 1/A-502

2 EXISTING ROOF CURB. REF MECH. FOR EQUIPMENT REMOVAL,

SEE 7/A503

3 PROVIDE EXISTING SKYLIGHT CURB, SEE 7/A503

4 30" X 72" ROOF HATCH AT EXIST ROOF, SEE 5/501, SEE STRUC

FOR SUPPORT FRAME

5 ESS-1, SEE 1/A-132 & 2/A -153

6 ROOF LADDER FROM LOW TO HIGH ROOF, SEE 2/A530

7 EXIST ROOF DRAIN

9 PATCH EXIST METAL DECK AT EXIST OPNG (SEE STRUCT), AND

PROVIDE IN-FILL ROOFING ASSEMBLY TO MATCH EXIST ROOF

ASSEMBLY.

10 30" X 72" ROOF HATCH, SEE 6/502, SEE STRUC FOR SUPPORT

FRAME

11 EXHAUST FAN, SEE 2/A501

12 METAL CANOPY, SEE ELEVATIONS

13 WALKWAY PAD

14 TAPERED INSUL/CRICKET, ROOF SADDLE: 1"/FT BACKSLOPE,

FOR SURFACE SLOPE OF 1/2" /FT MIN

15 SCUPPER & DOWNSPOUT, SEE 1,2,4, & 6/A503

16 GRAVITY VENTILATOR, SEE 2/A501 (AT PEMB SSMR - CRICKET,

CURB, AND FLASHING PER MFR)

17 MAKE-UP AIR UNIT, SEE 2/A501 FOR CURBING AND 4/A501 FOR

CONDUIT AND PIPE FLASHING. SEE MECHANICAL

18 VENT PIPE, SEE 1/A501 (AT PEMB SSMR - FLASHING PER MFR)

19 EXIST MOD-BIT HIGH ROOF AT EXIST TOWER

20 EXIST SSMR; TRAPEZOIDAL RIB WITH MECHANICALLY SEAMED

SEAMS AND CONCEALED FASTENERS AND CLIPS. REFER TO

PHOTOS ON SHEET A-202

21 EXIST STEEL PARAPET LADDER. REFINISH WITH PNT-1

22 EXHAUST FAN ON EXISTING 30" X 30" CURB, SEE MECHANICAL

23 ROOF ACCESS LADDER, SEE 1/A531

24 CONDENSER UNIT, SEE 7/A502 FOR CURBING AND 4/A501 FOR

CONDUIT AND PIPE FLASHING. SEE MECHANICAL

25 EXISTING SCUPPER

26 GUARDRAIL, SEE 6/A501

27 EXHAUST FAN ON NEW 19" x 19" CURB, SEE 2/A501

28 EXHAUST FAN ON EXISTING 20" x 20" CURB, SEE MECH

30 MAKE-UP AIR UNIT ON EXISTING 78"x 35" CURB, SEE MECH

31 ROOFTOP FAN ON EXISTING 32"x 32" CURB, SEE MECH

32 ROOFTOP FAN ON EXISTING 24"x 24" CURB, SEE MECH

33 RADON PIPE AT PEMB SSMR, SEE A-110

34 MECHANICAL UNIT, SEE 3/A502 FOR CURBING AND 5/A502 FOR

CONDUIT AND PIPE FLASHING. SEE MECHANICAL

35 CONDENSING UNIT, SEE 4/A502 FOR CURBING AND 5/A502 FOR

CONDUIT AND PIPE FLASHING. SEE MECHANICAL

36 GRAVITY VENTILATOR, SEE 3/A502

37 EXHAUST FAN, SEE 3/A502

38 VENT PIPE, SEE 5/A502

39 ROOFTOP DUCTWORK, MOUNTING PER DUCT MFR, FLASH SIM

TO 1/A-501. SEE MECH.

40 EXISTING ROOF CAP CURB

41 PROVIDE 1" INSULATION AT SCUPPER. PROVIDE SLOPED

INSULATION AT 1/2" PER FT. PROVIDE CRICKETS AT SCUPPER.

42 RADON PIPE, SEE 2/A-502 AND A-120

GENERAL NOTES - ROOF PLAN

A. ROOF SYSTEM: PEMB STANDING SEAM ROOF PANEL WITH BATT

INSULATION WITH WEATHER BARRIER ON PEMB GIRTS.

B. FOR ROOF WIND UPLIFT DESIGN REQUIREMENTS, SEE STRUCTURAL

C. FOR ALL DECK BEARING ELEVATIONS, SEE STRUCTURAL

D. FOR DOWNSPOUT LOCATIONS, SEE EXTERIOR ELEVATIONS

E. COORDINATE THE LOCATION OF ALL MECHANICAL AND PLUMBING

ITEMS WITH MECHANICAL AND PLUMBING SHEETS

0 8' 16' 32'

A

M E

N D

M E

N T

/2

/2

A

M E

N D

M E

N T

/1

/2

11 JULY 2024

W

2Q R

R

_P la ns -0

A-222

A-221

A-222

A-221

A-321

A-321

A-321

A-324

A1

AF

AE

AD

AC.8

AC

AB

AA.2

AA

A7 A5 A4 A3

/8

1/2" / 12"

/4

11' - 3 1/2" 42' - 5" 50' - 7"

1/2" / 12"

TYP

TYP

TYP

TYP

TYP

TYP

TYP

A2A6

38 38

38 38

1/2" / 12"

A-505

DN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M a rs h a ll

S t

N E

M in n e a p o lis

-1

R S

P A r c h it e c t s

L td

P N

P

F Y

.6

.7

.6

.7 f a x rs p a rc h .c o m

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED BY

ME OR UNDER MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED ARCHITECT UNDER

THE LAWS OF THE STATE OF MINNESOTA.

DATE SIGNED

LICENSE NUMBER

NAME

CERTIFICATION

A-181

A M

S A

/V M

S

R O

O F

P L A

N

P E

R R

IN

E

F

L O

R

ID

A L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y

T G

R U

N D

T N

E R

N C

H R

IS

T

IA

N

S O

N

D N

O R

B A

C K

C B

R O

S S

M A

N

F

E B

R U

A R

Y

C E

R T

IF

IE

D F

IN

A

L

A R

M Y

R E

S E

R V

E C

E N

T E

R A

N D

A M

S A

C A

R -7

F Y

11902

26 APRIL 2024

David C. Norback

GENERAL NOTES - ROOF PLAN

A. ROOF SYSTEM: MODIFIED BITUMEN W/ R-20 RIGID INSUL OVER

VAPOR RETARDER AND ROOF BOARD OVER METAL DECK

B. TAPERED BOARD ROOF INSULATION TO SLOPE AT 1" PER FOOT

TO PROVIDE A FINISHED SURFACE SLOPE OF 1/2" PER FOOT UNO

C. PROVIDE TAPERED BOARD CRICKET INSULATION AT ALL ROOF

TOP MECH UNITS AND ROOF PENETRATIONS AS REQUIRED TO

MAINTAIN POSITIVE ROOF SLOPE

D. FOR ROOF WIND UPLIFT DESIGN REQUIREMENTS, SEE

STRUCTURAL

E. FOR ALL DECK BEARING ELEVATIONS, SEE STRUCTURAL

F. FOR SCUPPER LOCATIONS, SEE EXTERIOR ELEVATIONS

G. COORDINATE THE LOCATION OF ALL MECHANICAL AND

PLUMBING ITEMS WITH MECHANICAL AND PLUMBING SHEETS

KEYNOTES - ROOF PLAN

NO. DESCRIPTION

1 MOD BIT ROOF OVER RIGID INSUL, OVER SLOPED STRUCTURE.

SEE 1/A-502

2 EXISTING ROOF CURB. REF MECH. FOR EQUIPMENT REMOVAL,

SEE 7/A503

3 PROVIDE EXISTING SKYLIGHT CURB, SEE 7/A503

4 30" X 72" ROOF HATCH AT EXIST ROOF, SEE 5/501, SEE STRUC

FOR SUPPORT FRAME

5 ESS-1, SEE 1/A-132 & 2/A -153

6 ROOF LADDER FROM LOW TO HIGH ROOF, SEE 2/A530

7 EXIST ROOF DRAIN

9 PATCH EXIST METAL DECK AT EXIST OPNG (SEE STRUCT), AND

PROVIDE IN-FILL ROOFING ASSEMBLY TO MATCH EXIST ROOF

ASSEMBLY.

10 30" X 72" ROOF HATCH, SEE 6/502, SEE STRUC FOR SUPPORT

FRAME

11 EXHAUST FAN, SEE 2/A501

12 METAL CANOPY, SEE ELEVATIONS

13 WALKWAY PAD

14 TAPERED INSUL/CRICKET, ROOF SADDLE: 1"/FT BACKSLOPE,

FOR SURFACE SLOPE OF 1/2" /FT MIN

15 SCUPPER & DOWNSPOUT, SEE 1,2,4, & 6/A503

16 GRAVITY VENTILATOR, SEE 2/A501 (AT PEMB SSMR - CRICKET,

CURB, AND FLASHING PER MFR)

17 MAKE-UP AIR UNIT, SEE 2/A501 FOR CURBING AND 4/A501 FOR

CONDUIT AND PIPE FLASHING. SEE MECHANICAL

18 VENT PIPE, SEE 1/A501 (AT PEMB SSMR - FLASHING PER MFR)

19 EXIST MOD-BIT HIGH ROOF AT EXIST TOWER

20 EXIST SSMR; TRAPEZOIDAL RIB WITH MECHANICALLY SEAMED

SEAMS AND CONCEALED FASTENERS AND CLIPS. REFER TO

PHOTOS ON SHEET A-202

21 EXIST STEEL PARAPET LADDER. REFINISH WITH PNT-1

22 EXHAUST FAN ON EXISTING 30" X 30" CURB, SEE MECHANICAL

23 ROOF ACCESS LADDER, SEE 1/A531

24 CONDENSER UNIT, SEE 7/A502 FOR CURBING AND 4/A501 FOR

CONDUIT AND PIPE FLASHING. SEE MECHANICAL

25 EXISTING SCUPPER

26 GUARDRAIL, SEE 6/A501

27 EXHAUST FAN ON NEW 19" x 19" CURB, SEE 2/A501

28 EXHAUST FAN ON EXISTING 20" x 20" CURB, SEE MECH

30 MAKE-UP AIR UNIT ON EXISTING 78"x 35" CURB, SEE MECH

31 ROOFTOP FAN ON EXISTING 32"x 32" CURB, SEE MECH

32 ROOFTOP FAN ON EXISTING 24"x 24" CURB, SEE MECH

33 RADON PIPE AT PEMB SSMR, SEE A-110

34 MECHANICAL UNIT, SEE 3/A502 FOR CURBING AND 5/A502 FOR

CONDUIT AND PIPE FLASHING. SEE MECHANICAL

35 CONDENSING UNIT, SEE 4/A502 FOR CURBING AND 5/A502 FOR

CONDUIT AND PIPE FLASHING. SEE MECHANICAL

36 GRAVITY VENTILATOR, SEE 3/A502

37 EXHAUST FAN, SEE 3/A502

38 VENT PIPE, SEE 5/A502

39 ROOFTOP DUCTWORK, MOUNTING PER DUCT MFR, FLASH SIM

TO 1/A-501. SEE MECH.

40 EXISTING ROOF CAP CURB

41 PROVIDE 1" INSULATION AT SCUPPER. PROVIDE SLOPED

INSULATION AT 1/2" PER FT. PROVIDE CRICKETS AT SCUPPER.

42 RADON PIPE, SEE 2/A-502 AND A-120

1/16" = 1'-0"A-181

AMSA/VMS - ROOF PLAN1

0 8' 16' 32'

A

M E

N D

M E

N T

/1

/2

11 JULY 2024

W

2Q R

R

_P la ns -0

WORK BAYS T/O MASONRY

138' - 0"

MWP INSIDE

CLOSURE (SEAL AND

SECURE)

5/8" FIRE RETARDANT TREATED PLYWOOD

5/8" FIRE RETARDANT TREATED PLYWOOD

2X 6 RIPPED FIRE RETARDANT TREATED

WOOD BLOCKING FOR SLOPE

2X8 FIRE RETARDANT TREATED WOOD BLOCKING

WB-1 (AIR BARRIER

SM-1 PREFINISHED METAL CAP

WITH KEEPER STRIP AT FRONT

2X8 FIRE RETARDANT

TREATED WOOD BLOCKING

CONTINUOUS CLEAT WITH

1" MINIMUM LEG

MWP-1

GASKETED FASTENER

MIN. 5/8" ROOF

COVERBOARD

2" RIGID INSULATION

CANT

BACKER

MOD BIT ROOF

SYSTEM - SEE

COUNTERFLASHING

BASE FLASHING

MEMBRANE OVER

COUNTERFLASHING

O V

E R

L A

P

MEMBRANE FLASHING TO

OVERLAP WB-1

5/8 GWB SHEATHING

/1 A-502

SM-1 PREFINISHED

METAL FLASHING

METAL PANEL CLOSURE

WB-1 OVER METAL

FLASHING

METAL PANEL AND

FLASHING FASTENED

TO WALL

FIRE RETARDANT 2x6, RIPPED TO MATCH

INSULATION THICKNESS

ABOVE, SECURE TO CMU

LOW WALL T/O MASONRY

118' - 0"

112' - 0"

CANT

BACKER

MOD BIT ROOF

SYSTEM - SEE

5/8" FIRE RETARDANT TREATED PLYWOOD

5/8" FIRE RETARDANT TREATED PLYWOOD

2X 6 RIPPED FIRE RETARDANT TREATED

WOOD BLOCKING FOR SLOPE

2X8 FIRE RETARDANT TREATED WOOD BLOCKING

WB-1 (AIR BARRIER)

SM-1 PREFINISHED METAL CAP

WITH KEEPER STRIP AT FRONT

CONTINUOUS CLEAT WITH

1" MINIMUM LEG

VENEER TIES AND HORIZ.

REINFORCING

HEAD JOINT WEEP

VENTILATORS AT 2'-0" O.C.

2X8 FIRE RETARDANT

TREATED WOOD BLOCKING

GASKETED FASTENER

MIN. 5/8" ROOF

COVERBOARD

2" RIGID INSULATION

COUNTERFLASHING

BASE FLASHING

MEMBRANE OVER

COUNTERFLASHING

O V

E R

L A

P

MEMBRANE FLASHING TO

OVERLAP WB-1

/1 A-502

1" RIGID INSUL TO

MATCH WALL PANEL

CONDITION ABOVE

SEE 1 AND 2/A-505 FOR

WALL COMPONENTS

A-505

BASE MEMBRANE FLASHING TO LAP

UP AND UNDER METAL PANELS

SHEET METAL COPING SLOPED TO

DRAIN (ROOFING SIDE)

SLOPE

BACK OF METAL FLASHING

AT BACK OF METAL PANEL

METAL COPING PANEL TO GO UP

AND BEHIND METAL PANEL ABOVE

J TRIM AT ADJACENT

WALL PANEL

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M a rs h a ll

S t

N E

M in n e a p o lis

-1

R S

P A r c h it e c t s

L td

P N

P

F Y

.6

.7

.6

.7 f a x rs p a rc h .c o m

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED BY

ME OR UNDER MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED ARCHITECT UNDER

THE LAWS OF THE STATE OF MINNESOTA.

DATE SIGNED

LICENSE NUMBER

NAME

CERTIFICATION

A-505

E X

T E

R

IO

R D

E T

A

IL

S

W A

L L

P E

R R

IN

E

F

L O

R

ID

A L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y

T G

R U

N D

T N

E R

N C

H R

IS

T

IA

N

S O

N

D N

O R

B A

C K

C B

R O

S S

M A

N

F

E B

R U

A R

Y

C E

R T

IF

IE

D F

IN

A

L

A R

M Y

R E

S E

R V

E C

E N

T E

R A

N D

A M

S A

C A

R -7

F Y

11902

26 APRIL 2024

David C. Norback

3" = 1'-0"A-505

AMSA/VMS - HIGH WALL PARAPET1

3" = 1'-0"A-505

AMSA/VMS - HIGH WALL/LOW ROOF DETAIL3

3" = 1'-0"A-505

AMSA/VMS - LOW WALL PARAPET4

1 1/2" = 1'-0"A-505

AMSA/VMS - FLASHING DETAIL AT HIGH-LOW WALL2

0 2" 4" 8"1"0 2" 4" 8"1"0 3" 6" 12" 18"

0 2" 4" 8"1"

A

M E

N D

M E

N T

/1

/2

1 1

11 JULY 2024

W

2Q R

R

_P la ns -0

ASSEMBLY HALL PARAPET

125' - 0"

END OF SM TO BE 1" MIN DOWNSLOPE FROM EXISTING LOCATION,

SO Z-CLOUSRE FLASHING IS DOWNSLOPE FROM EXIST

PENETRATIONS

MWP INSIDE CLOSURE

SM-3 FLASHING, 4"H MIN REAR

LEG SLOPE HORIZONTAL LEG

FOR DRAINAGE

EXISTING SM CAP FLASHING

EXISTING BLOCKING

SEALANT AT TOP OF WB-1 FLASHING

MEMBRANE

SM-3 FLASHING W/ KEEPER AT BOTTOM

FRONT AND COLOR MATCHING

GASKETED FASTENER AT TOP

/2

FIRE RETARDANT TREATED WOOD

BLOCKING, RIP TO MATCH MWP

THICKNESS

WB-1 FLASHING MEMBRANE, UP AND

OVER BLOCKING

FIRE RETARDANT TREATED 2x8 WOOD

BLOCKING, RIP TO MATCH INSULATION

THICKNESS BELOW, SECURE TO CMU

1"T MIN (R-5 MIN) W/ HORIZONTAL Z

FURRING 16" OC MAX

5/8" GYP SHEATHING

WB-1

MWP-3

EXISTING ROOF

WHERE OCCURS

(2) FIRE RETARDANT TREATED 2x6 WOOD

BLOCKING, RIP TO MATCH INSULATION

THICKNESS ABOVE, SECURE TO CMU

WB-1 FLASHING MEMBRANE

SEALANT

SM-1 SURFACE MOUNTED, ONE

PIECE COUNTERFLASHING

WB-1 FLASHING MEMBRANE, LAP

ONTO EXIST METAL ROOF

SM-1 FLASHING,

22GA MIN

15" +/-

1 1/2"SM-1 Z-CLOSURE

FLASHING SET IN

SEALANT, FORMED

AROUND SSMR RIBS,

SECURED TO SSMR

EXISTING SSMR

EXISTING ROOF

INSULATION,

VIF

EXISTING ROOF

DECK

EXISTING SSMR

RIB BEYOND

1 1

ASSEMBLY HALL PARAPET

125' - 0"

EXISTING SM CAP FLASHING

EXISTING BLOCKING

EXISTING CMU

2"T EIFS, BACK WRAPPED AT BOTTOM

WB-1

SM-1 COUNTERFLASHING

SEALANT

SM-1 FLASHING 4" MIN REAR LEG.

SLOPE HORIZONTAL LEG FOR

DRAINAGE

GAP, 1" (OR PER EIFS MFR)

WB-1 FLASHING MEMBRANE

SEALANT

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M a rs h a ll

S t

N E

M in n e a p o lis

-1

R S

P A r c h it e c t s

L td

P N

P

F Y

.6

.7

.6

.7 f a x rs p a rc h .c o m

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED BY

ME OR UNDER MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED ARCHITECT UNDER

THE LAWS OF THE STATE OF MINNESOTA.

DATE SIGNED

LICENSE NUMBER

NAME

CERTIFICATION

A-512

T R

A

IN

IN

G

B U

IL

D

IN

G

E

X T

E R

IO

R

D E

T A

IL

S

O

P T

IO

N

P E

R R

IN

E

F

L O

R

ID

A L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y

T G

R U

N D

T N

E R

N C

H R

IS

T

IA

N

S O

N

D N

O R

B A

C K

C B

R O

S S

M A

N

F

E B

R U

A R

Y

C E

R T

IF

IE

D F

IN

A

L

A R

M Y

R E

S E

R V

E C

E N

T E

R A

N D

A M

S A

C A

R -7

F Y

11902

26 APRIL 2024

David C. Norback

3" = 1'-0"A-512

TRAINING BUILDING - HIGH BAND AT ASSEMBLY WEST WALL - OPTION K2

0 2" 4" 8"1" 3" = 1'-0"A-512

TRAINING BUILDING - HIGH BAND AT ASSEMBLY WEST WALL1

0 2" 4" 8"1"

A

M E

N D

M E

N T

/1

/2

11 JULY 2024

W

2Q R

R

_P la ns -0

AREA C, E, F PARAPET

117' - 6"

B/O EIFS/MWP

112' - 8"

SEALANT AT TOP OF WB

WB-1

5/8" GYP SHEATHING

6"T R-19 MIN BATT INSULATION,

IN EXISTING STUD FRAMING

FIRE TREATED BLOCKING , RIP

HEIGHT TO MATCH EXISTING CMU

MORTAR JOINT LOCATION

WB-1 FLASHING MEMBRANE

MWP INSIDE CLOSURE

SM-3 FLASHING W/ HEMMED

FRONT DRIP

SM-3 BACK FLASHING/KEEPER

SM-3 FLASHING W/ VERT FRONT LEG.

BLIND SECURE AT FRONT, AND

COLOR MATCHED GASKETED

FASTENER AT BOTTOM REAR.

HEMMED REAR EDGE.

SEALANT

EXISTING SMOOTH CMU VENEER

EXISTING FLUTED CMU VENEER

MWP-3 WITH SM-3 J-TRIM AT TOP

MWP INSIDE CLOSURE (SEAL

AND SECURE)

SEALANT

SEALANT BTWN SHEET METAL

EXIST SM CAP FLASHING, VIF

WB-1 FLASHING MEMBRANE

AREA C, E, F PARAPET

117' - 6"

(3) ROWS 2x6 FRT BLOCKING, SECURED TO STUDS

MWP-3, PROVIDE SM-3 J-TRIM

AT TOP

WB-1

5/8" WOOD WALL SHEATHING

WB-1 FLASHING MEMBRANE

SEE 3/A-513 FOR TYPICAL

NOTES AND DIMENSIONS

SM-3

SM-1

AREA C, E, F PARAPET

117' - 6"

V A

R

IE

S

4" MIN

10" +/- VARIES, VIF.

(3) ROWS 2x6 FRT BLOCKING, SECURED TO STUDS

EXISTING CMU

EXISTING 8" STUD FRAMING,

FILL VOID W/ 8"T R-25 BATT

INSULATION

EXISTING ROOF ASSEMBLY

AND STRUCTURE

EXISTING SSMR PANELS

W/ TRAPEZOIDAL SEAMS

SM-1 CLOSURE FLASHING,

22 GA MIN. SECURE AT

SSMR RIB

SM-1 COUNTERFLASHING,

WITH SEALANT TO SM

FLASHING ABOVE

2"T EIFS, BACKWRAPPED

AT BOTTOM

SM-1 FLASHING. 4" MIN

REAR LEG. SLOPE

HEMMED HORIZONTAL LEG

FOR DRAINAGE

WB-1

5/8" WOOD WALL SHEATHING

WB-1 FLASHING

MEMBRANE

WB-1 FLASHING MEMBRANE

ONTO EXISTING ROOF PANEL

SEALANT

EXIST SM CAP FLASHING, VIF

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M a rs h a ll

S t

N E

M in n e a p o lis

-1

R S

P A r c h it e c t s

L td

P N

P

F Y

.6

.7

.6

.7 f a x rs p a rc h .c o m

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED BY

ME OR UNDER MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED ARCHITECT UNDER

THE LAWS OF THE STATE OF MINNESOTA.

DATE SIGNED

LICENSE NUMBER

NAME

CERTIFICATION

A-513

T R

A

IN

IN

G

B U

IL

D

IN

G

E

X T

E R

IO

R

D E

T A

IL

S

E

IF

S

/M W

P B

A N

D

P E

R R

IN

E

F

L O

R

ID

A L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y

T G

R U

N D

T N

E R

N C

H R

IS

T

IA

N

S O

N

D N

O R

B A

C K

C B

R O

S S

M A

N

F

E B

R U

A R

Y

C E

R T

IF

IE

D F

IN

A

L

A R

M Y

R E

S E

R V

E C

E N

T E

R A

N D

A M

S A

C A

R -7

F Y

11902

26 APRIL 2024

David C. Norback

3" = 1'-0"A-513

TRAINING BUILDING - TYPICAL HIGH BAND DETAIL - OPTION K1

3" = 1'-0"A-513

TRAINING BUILDING -

EXIST SSMR ROOF - RAKE TO WALL DETAIL - OPTION K2

0 2" 4" 8"1"

3" = 1'-0"A-513

TRAINING BUILDING - EXIST SSMR ROOF - RAKE TO WALL3

0 2" 4" 8"1"

0 2" 4" 8"1"

A

M E

N D

M E

N T

/1

/2

11 JULY 2024

W

2Q R

R

_P la ns -0

TERM BAR W/ CONT. SLNT

FLEXIBLE FLASHING

OVER TERM BAR

WB-1, LAP INTO OPNG

(WB-1 FLASHING

MEMBRANE AT CORNERS)

PRIMARY SEALANT AND

BACKER ROD

CANOPY (SEE )

CMU VENEER

AIR SPACE

RIGID INSUL

BOND BEAM. SEE

STRUCTURAL

SST DRIP EDGE SET IN MASTIC

CONT THRU-WALL FLASHING,

EXTEND UP WALL 12" MIN WITH

TERMINATION BAR AT TOP, SET

IN MASTIC. TRIM FLASHING 1/4"

FROM FACE OF MASONRY

VENEER; BONDED TO AND

LAPPED OVER SST STRIP BELOW

STEEL LOOSE LINTEL, SEE

STRUCT, PAINTED (SEE I-001)

CAVITY DRAINAGE MATERIAL

HEAD JOINT WEEP

VENTILATORS AT 1'-4" O.C.

CW - SEE A-601 FOR

ADDITIONAL INFORMATION

GLAZING

CARRY FLASHING 1/2" MIN

BEYOND END OF LINTEL

AND TURN UP TO FORM

END DAM IN HEAD JOINT.

END DAM 2" HIGH AT A MIN.

PAINT TO MATCH WALL

AT ALL EXPOSED CMU

7 1/2" +/- 3 1/2"

2" LAP

PRIMARY SEALANT

AND BACKER ROD

/7 A-520

SPRAY FOAM INSULATION

WD BLKG, SECURE TO CMU

WB-1, LAP INTO

CW JAMB 3"

RIGID INSUL

CMU

AIR SPACE

CMU VENEER

2" LAP

/1 A-520SEE

FOR TYPICAL

NOTES

1/2"

WALL BEYOND

CONCRETE SLAB

THRESHOLD SET IN MASTIC

SEALANT OVER

1/2" EXPANSION

MATERIAL

EXTERIOR

CONCRETE STOOP,

SEE STRUCT

CMU VENEER BEYOND

EXTERIOR INSULATED

ALUM DOOR. SEE A-600

FOR DOOR SCHEDULE

CONC

FOUNDATION -

SEE STRUC

SECONDARY SLNT

AND BACKER ROD

PRIMARY SLNT

AND BACKER ROD

METAL SOFFIT PANEL

ON HAT CHANNEL

5/8" FIRE RETARDANT

TREATED PLYWOOD

EXIST MTL FRAMING

FILLED WITH BATT

INSUL

EXISTING STEEL

STRUCTURE, VIF

CW FRAME

GLAZING

AS SCHED

CEILING

FIRE RETARDANT

TREATED WD BLOCKING.

VERIFY SIZE IN FIELD

(REMOVE EXIST BLKG)

SPRAY FOAM INSUL

WB-1 FLASHING

MEMBRANE, LAP 3"

MIN INTO OPNG

SLNT AND

BACKER ROD

SHIM AS

REQUIRED

J-TRIM

10" NOM (10" MIN, 11" MAX)

SECONDARY SEALANT

AND BACKER ROD

PRIMARY SEALANT

AND BACKER ROD

EXIST CMU

VENEER

ALUM FRAME

GLAZING

VIF

1"

EXIST RIGID INSUL

PRIMARY SLNT

AND BACKER ROD

SLNT AND

BACKER ROD

SEE PLAN FOR

PARTITION TYPE

EXIST BLOCKING

EXIST AIR SPACE

EXIST CONC

BACKUP

PRIMARY SLNT

AND BACKER RODPRIMARY SLNT AND

BACKER ROD

(ALLOW FOR CW WEEPING)

ALUM FRAME

GLAZING

EXIST SLNT AT JOINT

SHIM

EXIST CONC STOOP

VIF

1"

SLNT

FLOORING

AS SCHED

EXIST CONC

FOUNDATION

EXIST CONC SLAB

JAMB ANCHOR

SLNT AND

BACKER ROD

PRIMARY SLNT

AND BACKER ROD

EXIST CMU VENEER

ALUM FRAME

GLAZING

EXIST RIGID INSUL

EXIST AIR SPACE

ALUM DOOR

THRESHOLD BELOW

1"

T/ SLAB

100' - 0"

EXIST CONCRETE

SLAB

THRESHOLD SET IN MASTIC

SEALANT OVER

1/2" EXPANSION

MATERIAL

EXTERIOR CONCRETE

STOOP, SEE STRUCT

CMU VENEER BEYOND

EXTERIOR INSULATED ALUM

DOOR - SEE A-602 & A-603 FOR

OPENING SCHEDULE

1/2"

VIF

6 1/2"

EXIST CONCRETE

FOUNDATION

ALUM FRAME

108' - 0"

V E

R W

IT

H

M F

R

M

IN

M

A X

1" MAX GAP

B/O CANOPY

1" SPRAY FOAM INSULATION

MOUNTING AND REINFORCEMENT BY CANOPY MFR

WB-1 FLASHING MEMBRANE OVER BRACKET

PREFAB CANOPY WITH BRACKETS AT ENDS. VER MOUNTING REQS WITH MFR.

PROVIDE FLAT HEADED OR CONCEALED FASTENERS. SOFFIT AND FASCIA

SURFACES TO BE FLAT METAL. INTERNAL STRUCTURE AND FRAMING PER MFR

CANOPY INTERNAL GUTTER, SLOPE TO EAST

CANOPY DOWNSPOUT BEYOND

RIGID INSUL, SEE WALL SECTION FOR NOTES

4' - 0"

EXTEND WB-1 BEHIND MOUNTING PLATE

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M a rs h a ll

S t

N E

M in n e a p o lis

-1

R S

P A r c h it e c t s

L td

P N

P

F Y

.6

.7

.6

.7 f a x rs p a rc h .c o m

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED BY

ME OR UNDER MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED ARCHITECT UNDER

THE LAWS OF THE STATE OF MINNESOTA.

DATE SIGNED

LICENSE NUMBER

NAME

CERTIFICATION

A-520

E X

T E

R

IO

R D

E T

A

IL

S

C U

R T

A

IN

W A

L L

P E

R R

IN

E

F

L O

R

ID

A L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y

T G

R U

N D

T N

E R

N C

H R

IS

T

IA

N

S O

N

D N

O R

B A

C K

C B

R O

S S

M A

N

F

E B

R U

A R

Y

C E

R T

IF

IE

D F

IN

A

L

A R

M Y

R E

S E

R V

E C

E N

T E

R A

N D

A M

S A

C A

R -7

F Y

11902

26 APRIL 2024

David C. Norback

3" = 1'-0"A-520

AMSA/VMS - CURTAIN WALL HEAD DETAIL1

3" = 1'-0"A-520

AMSA/VMS - CURTAIN

WALL JAMB AT VESTIBULE2

3" = 1'-0"A-520

AMSA/VMS - CURTAIN

WALL SILL DETAIL AT VESTIBULE3

3" = 1'-0"A-520

TRAINING BUILDING

CURTAIN WALL HEAD AT EXIST OPENING4

3" = 1'-0"A-520

TRAINING BUILDING

CURTAIN WALL JAMB AT EXIST OPENING5

3" = 1'-0"A-520

TRAINING BUILDING

CURTAIN WALL SILL AT EXIST OPENING6

0 3" 6" 12" 18" 0 2" 4" 8"1"

0 2" 4" 8"1"

0 2" 4" 8"1"0 2" 4" 8"1"

0 2" 4" 8"1" 0 2" 4" 8"1"

3" = 1'-0"A-520

TRAINING BUILDING

ALUM DOOR JAMB AT EXIST OPENING8

0 2" 4" 8"1"

3" = 1'-0"A-520

TRAINING BUILDING

ALUM DOOR SILL AT EXIST OPENING9

0 2" 4" 8"1"

1 1/2" = 1'-0"A-520

AMSA/VMS - ENTRY CANOPY SECTION7

A

M E

N D

M E

N T

/1

/2

1 1

1 1

11 JULY 2024

W

2Q R

R

_P la ns -0

EXIST CMU TO REMAIN.

GROUT EXIST CMU SOLID

AT NEW OPENING. SEE

STRUCTURAL

CONTINUOUS

SEALANT

ALUM FRAMING

SYSTEM

STEEL STRUCTURE

FOR NEW OPENING,

SEE STRUCTURAL

RIGID INSULATION

CMU VENEER

STRAP ANCHOR

6"H RECTANGULAR OUTRIGGER, AT EA END. OUTRIGGERS TO MOUNT ON

OUTSIDE OF ANCHOR BRACKET, PROVIDE BLADE STIFFENERS AS REQUIRED

6" BLADES AT 45 DEG. SECURED AT OUTRIGGERS

ALUM ANCHOR BRACKET EXTRUSION. SIZE AND FASTENERS PER

SUNSHADE MFR

SUNSHADE BRACKET TO PENETRATE VERTICAL JOINT IN CMU VENEER.

PROVIDE 3/8"W SEALANT OVER BACKER ROD AT FACE OF CMU. SECURE TO

BACKUP CMU WITH THROUGH-BOLTS, PER SUNSHADE MFR REQUIREMENTS.

IF BRACKET PROVIDED IS TALLER THAN SHOWN, BRACKET SHALL ONLY BE

EXTENDED IN AN UPWARD DIRECTION TO ALLOW FOR FLASHING BELOW

SEE PLAN FOR

PARTITION TYPE

WOOD SHIM AS

REQUIRED

1" SPRAY FOAM INSLUATION

EXISTING RIGID INSULATION

3' - 0"

5" EQ 1" EQ 1" ... 1"

SST DRIP EDGE SET IN MASTIC

WD BLKG WITH SPRAY FOAM AT TOP

BACKER ROD AND SEALANT, BOTH SIDES

ALUM WINDOW

HEAD JOINT WEEP VENTS AT 1'-4" O.C.

FLEXIBLE FLASHING

OVER TERM BAR

CONT THRU-WALL FLASHING, EXTEND UP WALL 12" MIN WITH TERMINATION

BAR AT TOP, SET IN MASTIC. TRIM FLASHING 1/4" FROM FACE OF MASONRY

VENEER; BONDED TO AND LAPPED OVER SST STRIP BELOW

CAVITY DRAINAGE MATERIAL

STEEL LOOSE LINTEL, SEE STRUCT, PAINTED (SEE I-001)

CARRY FLASHING 1/2" MIN BEYOND END OF LINTEL AND TURN UP TO FORM

END DAM IN HEAD JOINT. END DAM 2" HIGH AT A MIN.

WB-1 AT FACE OF WALL (WB-1 FLASHING MEMBRANE AT CORNERS)

WB-1 FLASHING MEMBRANE OVER BRACKET AND THROUGH WALL FLASHING

T-BAR BELOW

W

APC-1 BELOW

CONTINUOUS

SEALANT

ALUM FRAMING

SYSTEM

3/8" W CONTINUOUS SEALANT

AND BACKER ROD

STEEL TUBE, SEE

STRUCTURAL

RETURN GYP BD TO

WINDOW FRAME,

WITH J-BEAD

STRAP ANCHOR

SEE PLAN FOR

PARTITION TYPE

5/8 PLYWOOD,

SHIM

WOOD SHIM

EXISTING RIGID INSULATION

EXISTING FLUTED CMU VENEER,

SAWCUT TO NEW OPENING

DIMENSIONEXIST CMU TO REMAIN.

GROUT EXIST CMU SOLID

AT NEW OPENING. SEE

STRUCTURAL

10" (3/16") GALV STEEL

PLATE FULL HT OF

OPENING.SECURE TO

BACKUP CMU WITH 3/8"

DIA EXP ANCHORS 16" OC

MAX. PROVIDE OPENINGS

IN PLATE TO COORDINATE

WITH WINDOW ANCHORS.

SET IN SEALANT BETWEEN

PLATE AND CMU VENEER,

AT THE PLATE LEADING

EDGE. PAINT PNT-27

O P

N G

R .O

EXISTING AIR SPACE

4"

1/2"

SILL BELOW

SEALANT AT APC-1 SILL

/8

WOOD BLKG

EXIST CMU TO REMAIN

SEALANT

SOLID SURFACE

SILL SSM-1

CONTINUOUS

SEALANT

ALUM FRAMING

SYSTEM

CONTINUOUS SEALANT AND

BACKER ROD (ALLOW FOR WEEP)

ALUM WINDOW

EXISTING CMU VENEER

EXISTING RIGID INSULATION

NEW CMU

VER HT IN FIELD

SEE PLAN FOR

PARTITION TYPE

STEEL PLATE BEYOND, SEE JAMB

DETAIL

10" 1/2"

HHS - SEE

STRUCURAL

SEE 3/A-522 FOR TYP NOTES.

VIF DEPTH OF CAST STONE TO

COORD WITH EXIST CAVITY

WALL DIM

EXISTING CMU VENEER

EXISTING RIGID

INSULATION

EXISTING

CMU WALL

SEE PLAN FOR

PARTITION TYPE

CONTINUOUS

SEALANT

ALUM FRAMING

SYSTEM

RETURN GYPSUM

TO WINDOW FRAME

STRAP ANCHOR

FIRE RETARDANT

5/8 PLYWOOD, SHIM

CONTINUOUS SEALANT

AND BACKER ROD

WOOD SHIM

EXISTING LINTEL, PAINT

CEILING MOUNT

WINDOW SHADE

(WS-1)

PEMB-W1

CONTINUOUS

SEALANT

ALUM FRAMING

SYSTEM

RETURN GYPSUM

TO WINDOW FRAME

STRAP ANCHOR

FIRE RETARDANT

5/8 PLYWOOD, SHIM

SEE PLAN FOR

PARTITION TYPE

AT SIMILAR

CONDITION,

LINER PANEL AT

UNIT STORAGE

AREAS IN LIEU OF

GYPSUM BOARD

WOOD SHIM

CEILING MOUNT

WINDOW SHADE

(WS-1)

FACE OF WINDOW

TO ALIGN WITH FACE

OF PEMB-W1

PEMB SM DRIP

SPRAY FOAM AT C-

CHANNEL. IF BOXED

FRAMING IS USED, SPRAY

FOAM INSIDE BOXED

FRAMING

BACKER ROD

AND SEALANT

5/8" PLYWOOD

EXIST CMU BOND BEAM

EXIST CMU VENEER

ALUM FRAME

ALUM DOOR

SECONDARY SLNT

AND BACKER ROD

GLAZING

1"

EXIST LINTEL, PAINT

PRIMARY SLNT AND

BACKER ROD

V.I.F.

10 1/2"

A L

IG

N

SLNT AND

BACKER ROD

ANCHOR

ALUM FRAME

GLAZING

SLNT AND

BACKER ROD,

BOTH SIDES

V .I .F

/2

EXISTING CONC

COLUMN

ALIGN ALIGN

ALIGN EDGE OF

CURTAIN WALL

WITH GYP FINISH

O P

N G

R .O

WD BLOCKING

BACKER ROD

AND SEALANT

HSS, SEE

STRUCTURAL

/1 A-521

BACKER ROD

AND SEALANT

ALUM FRAME ALUM DOOR

SECONDARY SLNT

AND BACKER ROD

GLAZING

1"

SEE FOR

TYPICAL NOTES

FIELD VERIFY EXIST

COL DIMENSIONS

OVER OVERALL

OPENING SIZE FOR

ALUM FRAME

PRIMARY SLNT AND

BACKER ROD

EXISTING

CMU WALL

EXISTING L ANGLE

TO REMAIN

EXISTING CMU

VENEER

EXISTING RIGID

INSULATION

EXISTING PRECAST

SILL. PROVIDE NEW

APC-1 SILL WHERE

INDICATED ON

ELEVATIONS

SEALANT

SOLID SURFACE

SILL SSM-1

CONTINUOUS

SEALANT

ALUM FRAMING

SYSTEM

PREFINISHED METAL

FLASHING

CONTINUOUS

SEALANT AND

BACKER ROD

(ALLOW FOR WEEP)

ALUM WINDOW

FIRE RETARDANT

5/8 PLYWOOD, SHIM

SEE PLAN FOR

PARTITION TYPE

STRAP ANCHOR

STEEL PLATE

BEYOND. SEE JAMB

DETAIL

10"

1/2"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M a rs h a ll

S t

N E

M in n e a p o lis

-1

R S

P A r c h it e c t s

L td

P N

P

F Y

.6

.7

.6

.7 f a x rs p a rc h .c o m

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED BY

ME OR UNDER MY DIRECT SUPERVISION AND

THAT I AM A DULY LICENSED ARCHITECT UNDER

THE LAWS OF THE STATE OF MINNESOTA.

DATE SIGNED

LICENSE NUMBER

NAME

CERTIFICATION

A-521

E X

T E

R

IO

R D

E T

A

IL

S

C U

R T

A

IN

W A

L L /W

IN

D

O W

P E

R R

IN

E

F

L O

R

ID

A L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y

T G

R U

N D

T N

E R

N C

H R

IS

T

IA

N

S O

N

D N

O R

B A

C K

C B

R O

S S

M A

N

F

E B

R U

A R

Y

C E

R T

IF

IE

D F

IN

A

L

A R

M Y

R E

S E

R V

E C

E N

T E

R A

N D

A M

S A

C A

R -7

F Y

11902

26 APRIL 2024

David C. Norback

3" = 1'-0"A-521

TRAINING BUILDING - WINDOW HEAD IN NEW OPENING WITH SUNSHADE1

3" = 1'-0"A-521

TRAINING BUILDING - WINDOW JAMB AT NEW OPENING2

3" = 1'-0"A-521

TRAINING BUILDING - WINDOW SILL IN NEW OPENING3

3" = 1'-0"A-521

TRAINING BUILDING - WINDOW

HEAD IN EXISTING OPENING7

3" = 1'-0"A-521

ORGANIZATIONAL STORAGE -

TYPICAL WINDOW HEAD (JAMB SIM)4

3" = 1'-0"A-521

TRAINING BUILDING - ALUM DOOR

HEAD IN EXISTING OPENING5

3" = 1'-0"A-521

TRAINING BUILDING INTERIOR

CURTAIN WALL JAMB AT EXIST COLUMN8

0 2" 4" 8"1" 0 2" 4" 8"1"

0 2" 4" 8"1"

0 2" 4" 8"1"

0 2" 4" 8"1"

0 2" 4" 8"1"

0 2" 4" 8"1"

0 2" 4" 8"1"3" = 1'-0"A-521

TRAINING BUILDING ALUM DOOR

HEAD AT NEW OPENING10

0 2" 4" 8"1"

3" = 1'-0"A-521

TRAINING BUILDING -

WINDOW SILL IN EXISTING OPENING9

A

M E

N D

M E

N T

/1

/2

11 JULY 2024

W

2Q R

R

_P la ns -0

APC-1 BEYOND

SOLID SURFACE SILL

BEYOND

SEALANT AND BACKER ROD

ALUM WINDOW

CMU VENEER

5/8" GYP BOARD

RETURNED TO WINDOW

SEE PLAN FOR

PARTITION TYPE

STRAP ANCHOR AND

SCREW

5/8" PLYWOOD SHIM

3" LAP WOOD BLOCKING AND SHIM

AIR SPACE

3/4"

CMU

CONTINUOUS

SEALANT

SOLID SURFACE SILL

W/ EASED EDGE

CONTINUOUS SEALANT

WB-1, WITH WB-1 FLASHING MEMBRANE AT CORNER

CONDITION AT TOP OF CMU, EXTEND ONTO CMU SILL

6" MIN

CONT 5/16" GALV BENT PL. 5" VERT BACK LEG,

HORIZ LEG 1/4" SHORTER THAN FACE OF VENEER

(VIF). SECURE W/ 3/8"DIA GALV EXP BOLT W/ 3"

MIN EMBEDMENT, AT 2'-0" OC MAX; MIN 3 BOLTS

PER SILL CONDITION.

SS DRIP EDGE SET IN MASTIC

WEEP VENTILATORS

AT 1'-4" O.C.

RIGID INSUL

THROUGH WALL FLASHING, EXTEND UP AND RETURN

3" MIN BACK FROM FACE OF CMU. CREATE 1"H MIN END

DAMS AT JAMBS. TRIM FLASHING 1/2" FROM FACE OF

MASONRY VENEER, BONDED TO AND LAPPED OVER SS

DRIP EDGE BELOW.

PREFINISHED METAL FLASHING, SM-4, WITH HEMMED

LEADING EDGE. SET IN SEALANT, SECURE AT

PROVIDE REAR AND JAMB DAMS 1/2"H

CONTINUOUS SEALANT AND

BACKER ROD (ALLOW FOR WEEP)

ALUM WINDOW WITH EXTENSION

CLIPS AND ANCHORS AS REQUIRED

STRAP ANCHOR AND

SCREW

3/4" PRESSURE

TREATED PLYWOOD

EDGE BEAD

SEE PLAN FOR

PARTITION TYPE

APC-1V

.I

.F

/8

AIR SPACE

1/2"

1 1/2"

2"

WALL DIM

VIF WITH

CAVITY

4" 1" B A

C K

U P

C M

U H

T

V

IF

T O

M A

T C

H

/8

SEALANT

MORTAR BED WITH VOIDS FOR HORIZ WEEP VENTILATORS

AT 2'-0"OC MAX, MIN 2 EA AT EA WDW SILL. PROVIDE

SEALANT AT EXTERIOR EXPOSED EDGE OF MORTAR BED JT

SILL 'L' STRAP W/ WELDED DOWEL PIN AT BOTH ENDS OF

SILL AND AT INTERMEDIATE SILL JTS (IF APPLICABLE). SEAL

AT THROUGH WALL FLASHING

AT EXIST WALL INFILL (TRAINING BLDG),

MATCH EXIST ADJ CAVITY WALL, VIF

1" SPRAY FOAM INSULATION

SEE STRUCTURAL FOR WALL REINFORCEMENT AND FILL

SST DRIP EDGE SET IN MASTIC

STEEL LOOSE LINTEL, SEE STRUCT, PAINTED (SEE I-001)

BACKER ROD AND SEALANT, BOTH SIDES

ALUM WINDOW

WB-1 OVER BRACKET

HEAD JOINT WEEP VENTS AT 1'-4" O.C.

AS SCHED

CEILING

SEE WALL SECTION FOR WALL ASSEMBLY NOTES AND DIMS

FLEXIBLE FLASHING

OVER TERM BAR

CONT THRU-WALL FLASHING, EXTEND UP WALL 12" MIN WITH TERMINATION BAR AT TOP, SET IN MASTIC. TRIM FLASHING 1/4" FROM FACE OF MASONRY VENEER; BONDED TO AND LAPPED OVER SST STRIP BELOW

CAVITY DRAINAGE MATERIAL

CARRY FLASHING 1/2" MIN BEYOND END OF LINTEL…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .