W912QR23R0003_Plans_0001.pdf

PDF 4 MB Posted

Attached to
Maxwell AFB, AL B. 1455 Nose Bay Hangar Renovation
Solicitation number
W912QR23R0003
Issued by

About this file

This solicitation is for renovation work at Maxwell Air Force Base in Alabama. The project scope involves repairs to Aircraft Maintenance Building 1455 to support beddown of the MH-139 helicopter fleet. The estimated construction cost is between $5 million and $10 million. A site visit is scheduled for January 10, 2023 at 9:30am Central Time, with a request for interested contractors to submit personnel details by January 4, 2023 to facilitate base access. The solicitation is full and open with a best value tradeoff source selection. The procurement includes a 10% price evaluation preference for HUBZone small businesses. The NAICS code is 236220 with a size standard of $39.5 million. The solicitation number is W912QR23R0003.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

4 4 4

4S

S

S

S

A V

A V

A V

A V

A V A V

A VA V

4 4

4 4

4 4

+48"

+48"

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

JJJJJJ

J

JJJ

J

JJJ

JJ

JJJJJJ

J

J

J

J

J

J J

JJ

J

J

J

J JJ J

E.A

E.A.8

E.B.5

E.D.2

E.D.4

E.D.5

E.D.1

E.3

E.4

E.5

E.6

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

M A

T C

H L

IN

E

A

E P

GFI

GFIGFI

GFI

GFI

GFI

2.1 2.2 2.3 2.4 2.5 2.6

B.1

B.2

B.4

C.1

C.9

MH1

TX-ML1

ML1

TX-R1

R1

TX-TR1

R1BR1AHL1

AIE PTT

TELECOM

MULTI-PURPOSE

MULTI-PURPOSE

CLASSROOM

CLASSROOM

TRS

STUDENT

WORK AREA

MEN'S RR

WOMEN'S RR

VESTIBULE

CORRIDOR

FIRE ROOM

WPT

105A

ADMINISTRATION

105E

OFFICE

105D

OFFICE

105C

OFFICE

105B

WELLNESS

ADMINISTRATION

BREAK ROOM

JANITOR'S

REGISTRARS

102A

REGISTRARS OFFICE

S02

STAIR 2

GFI

GFI

GFI

GFI

GFI

TR1

GFI

ELECTRICAL

CPT

TX-BOEING

OFT

CKT BKR

BOEING PDU

GFI

FCU-4

FCU-5

FCU-3

VAV-1-04

VAV-1-06

VAV-1-11

VAV-1-12

VAV-1-10

VAV-1-14

VAV-1-07104 104

105 105

36"X30"X8"

J-BOX

AMRS METER

GEN CONN

CAB

R1C

SEC-DOOR-1

FMCP

SEC-DOOR-2

SEC-ACS

SEC-IDS

GFI/WP

VAV-1-08

VAV-1-09

VAV-1-13

128128

IAST-DISC

AIE PTT-DISC

E-401

F5

E-401

A1

115A

STORAGE

110A

CORRIDOR

IAST

S01

STAIR 1

CORRIDOR

AIE PTT

-12R1C

-13R1C

-15R1

-6R1A

-24R1A

-1R1A

-31R1A

-13R1A

-4R1A

-7R1A

-3R1A

-25R1A

040040

E-401

A4

-8R1A

-21R1A

-18R1A -19R1A

-27R1A

-26R1A

-23R1A

-1FA

-12ML1

-15R1A

-14R1A-2,4,6,35R1D

-6ML1

-7,9,11MH1

-5R1

-1R1B

-7,9,11,39R1D

-1,3,5,36R1D

-8,10,12,37R1D

-15TR1

138-9R1C

-16,18,20,38R1D

-22,24,26,41R1D

-5R1A

-17R1A

GFI/WP

-10ML1

-9,11R1

FCU-6 FCU-7

-19ML1

-21ML1

-13R1

MICROWAVE

COFFEE

DISHWASHER

040040

R1D

-1R1C

-3R1C

-1,3R1

-8,10R1

PROPOSED NEW CRANE

DISCONNECT LOCATION

-4R1C

-13,14,15,34R1D

-2FA

059 059

-5ML1

EF-5

-16R1A

-22R1A

-30,32,34,36R1A

109 109

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

A

U G

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

M A

X W

E L L

A

IR

F O

R C

E B

A S

E

J

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA B

B

B1455

EP103

P A

R T

IA

L P

O W

E R

P L A

N

L E

V E

L

A

R E

A B

A M

C W

H O

R T

E R

A F

O R

M A

N

K .H

O G

A N

S X

H T

E

P

KEYNOTES

040 PROVIDE REMOTE INDICATOR AND RESET GFCI IN AN

ACCESSIBLE LOCATION. PROVIDE LABEL IDENTIFYING THE

APPLIANCE SERVED.

059 PROVIDE POWER CONNECTION TO DOOR HOLD OPEN.

COORDINATE REQUIREMENTS WITH MANUFACTURER AND FIRE

PROTECTION.

101 REMOVE EXISTING CRANE DISCONNECT AND PROVIDE NEW

DISCONNECT IN NEW LOCATION. EXTEND CONDUIT AND

CONDUCTORS TO NEW LOCATION. PROVIDE CRANE

DISCONNECT RELOCATION MEETING WITH CONTRACTING

OFFICER AND USERS TO DETERMINE IDEAL LOCATION FOR THE

CRANE DISCONNECT SWITCH. REMOVE EXISTING CRANE

DISCONNECT AND PROVIDE NEW DISCONNECT SWITCH IN

LOCATION PER THE RELOCATION MEETING. PROVIDE TESTING

AND COMMISSIONING OF CRANE PRIOR TO START OF

CONSTRUCTION. CRANE IS TO REMAIN OPERATIONAL AFTER

CONSTRUCTION COMPLETION. TEST AND COMMISSION CRANE

AFTER RELOCATION OF CRANE DISCONNECT AND CONTROLS.

PROVIDE NEW DISCONNECT AND CIRCUIT TO MATCH EXISTING.

104 PROVIDE SURFACE-TYPE FLOOR BOX WITH COMBINATION

POWER AND DATA. PROVIDE DUPLEX 5-20R RECEPTACLE AND

SPACE FOR DATA. REFER TO TELECOM PLANS. COORDINATE

WITH ARCHITECTURAL AND INTERIORS FOR DIMENSIONS TO

LOCATE BELOW TABLES.

105 PROVIDE IN-CARPET EXPOSED RACEWAY SYSTEM FROM THE

WALL TO THE FLOOR BOX.

107 PROVIDE UNDERGROUND CONDUITS FROM TRANSFORMER TO

EXTERIOR JUNCTION BOX FOR SERVICE CONDUCTORS TO

MDP2. COORDINATE WITH THE LOCAL ELECTRICAL UTILITY

COMPANY (CAEC) TO INSTALL THE CONDUITS INTO THE

SECONDARY SECTION OF THE TRANSFORMER.

109 PROVIDE A 10-WIRE (4-4-2), 2+2 CIRCUIT CONFIGURATION TO

THE WORKSTATIONS. PROVIDE 8#10, 2#10 GROUND IN 1-1/4"

CONDUIT AND MAKE WHIP CONNECTION TO FURNITURE

ACCORDING TO FURNITURE MANUFACUTURER REQUIREMENTS.

ONE DUPLEX OUTLET SHALL HAVE CONTROLLED

RECEPTACLES AND THE THREE OTHER DUPLEX OUTLET WILL

HAVE NON-SWITCHED RECEPTACLES. LABEL CONTROLLED

RECEPTACLES ACCORDINGLY. COORDINATE WITH FURNITURE

MANUFACTURER TO PROVIDE ELECTRICAL CONNECTIONS AND

TESTING OF FURNITURE RECEPTACLES.

120 MOUNT THE SWITCH IN ELEVATORT PIT AT REACHING HEIGHT

NEAR ELEVATOR OPENING.

128 PROVIDE TWO 2-POLE 3-WIRE 208 VAC OUTLET FOR THE

COCKPIT PROCEDURAL TRAINER (CPT).

129 PROVIDE A DEDICATED DUPLEX OUTLET FOR THE WEAPONS

PROCEDURAL TRAINER (WPT).

130 PROVIDE A L5-20P PLUG FOR THE WEAPONS PROCEDURAL

TRAINER (WPT).

135 PROVIDE A DISCONNECT FOR THE IAST TOWARDS THE REAR

OF THE TRAINER.

136 PROVIDE A DISCONNECT FOR THE ALTERNATE INSERTION

EXTRACTION PART-TASK TRAINER (AIE PTT) AT THE BOTTOM OF

THE SCAFFOLD SYSTEM.

138 PROVIDE RECEPTACLES FOR TELECOMMUNICATIONS RACK.

COORDINATE MOUNTING LOCATIONS WITH TELECOM

DRAWINGS.

1/8" = 1'-0"A1

PARTIAL POWER PLAN - LEVEL 1 - AREA B

GENERAL NOTES - POWER

A REFER TO A2/E-501 FOR CONTROLLED RECEPTACLES WIRING

DIAGRAM.

B REFER TO E-602 FOR ADDITIONAL EQUIPMENT CONNECTION

INFORMATION. FOR INTEGRAL DISCONNECTS, REFER TO

EQUIPMENT SCHEDULES AND MECHANICAL SHEETS. INTEGRAL

DISCONNECTS ARE SHOWN AS HALF-TONED.

C CONDUIT RUNS AS SHOWN ON THE PLANS ARE DIAGRAMMATIC

ONLY. EXACT LOCATION AND METHOD OF SUPPORT MUST BE

DETERMINED IN THE FIELD.

E PROVIDE SOURCE (PANEL & CIRCUIT #) LABEL ON ALL NEW

RECEPTACLE COVERS.

A

M E

N D

M E

N T

-0

-2

A M

E N

D M

E N

T

-0

-2

AARON McWHORTER

100310

L I C ENS ED

P R

O

F

ESS IONA L ENG

IN

E E

R

S TATE OF TEXA

S

TEXAS REGISTERED

ENGINEERING FIRM F-2966

12 AUG 2022

W

2Q R

R

_P la ns _0

E.1

E.A

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.2

29' - 4"

/4

/4

/4

/4

A1

S-301

114114

84' - 8"

CL OF HANGAR

19' - 8" 19' - 10 7/8"

14" THICK EXISTING CONCRETE SLAB

9" THICK EXISTING

CONCRETE SLAB

9" THICK EXISTING

CONCRETE SLAB

121TYP

M

IN

M

IN

M

IN

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET OF

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E M

B E

R

E O

L N

E S

S

F

IL

E N

A M

E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA A

A

B1455

SD102

P A

R T

IA

L D

E M

O L

IT

IO

N

L

V E

L

A

R E

A A

A B

A N

N E

R O

T

D O

R T

O N

A S

A V

O

IE

S X

H T

S

D

1/8" = 1'-0"A1

PARTIAL DEMOLITION PLAN - LEVEL 1 - AREA A

SHEET NOTES - DEMOLITION PLAN

A FIELD VERIFY EXISTING DIMENSIONS, MEMBER SIZES,

ELEVATIONS AND OTHER CONDITIONS. NOTIFY

CONTRACTING OFFICER OF ANY DISCREPANCIES TO

RECEIVE REVISED RECOMMENDATIONS..

B VERIFY LOCATIONS OF ALL UNDERGROUND AND

ABOVE GROUND UTILITIES PRIOR TO START OF

CONSTRUCTION. REPAIR, REROUTE, OR REPLACE

UTILITIES AS REQUIRED TO PERFORM NEW

CONSTRUCTION.

C INSTALL REINFORCING CHANNELS AROUND NEW

OPENINGS PRIOR TO ENLARGING OPENINGS. RE: WALL

ELEVATIONS.

KEYNOTES

106 EXISTING MASONRY WALL

112 SAWCUT AND REMOVE EXISTING SLAB FOR NEW

CONCRETE FOOTING

114 NEW OPENING IN EXISTING CMU WALL REFER TO

ELEVATION

119 EXISTING TENSION ROD ENCASEMENT. MUST REMAIN

UNDISTURBED. PROCEED WITH EXTREME CAUTION

WHEN CUTTING EXISTING SLAB NEAR GRID LINES E.A.8,

E.B.5 & E.C.4 TO AVOID EXISTING TENSION RODS AND

ENCASEMENT. DO NOT CUT WITHIN 12" EITHER SIDE

OF THESE GRID LINES.

121 EXISTING STEEL COLUMN

A M

E N

D M

E N

T

J

A N

ALEX BANNEROT

OF TEXASS

TATE

ALNOI

SS

E

F O

R P

ENG

IN

E E

R

NSEDECI

L 91686

12 AUG 2022

W

2Q R

R

_P la ns _0

4 4 4

4S

S

S

S

A V

A V

A V

A V A V A V

A VA V4 4

4 4

4 4

+48"

+48"

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

E.A

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.3

E.4

E.5

E.6

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

M

AT

C

H

LI

N E

A1 T-

T-401 A1

TELECOM

FIRE ROOM

WPT

CPT

ELECTRICAL

E01

ELEVATOR

MULTI-PURPOSE

MULTI-PURPOSE

CLASSROOM

CLASSROOM 109

MEN'S RR

WOMEN'S RR

STUDENT

WORK AREA

VESTIBULE

CORRIDOR

JANITOR'S

102A

REGISTRARS OFFICE

REGISTRARS

TRS

ADMINISTRATION

105A

ADMINISTRATION

BREAK ROOM

105B

WELLNESS

105C

OFFICE

105D

OFFICE

105E

OFFICE

+72" +72"

+72" +72"

2.62.52.42.32.22.1

B.1

B.2

B.4

C.1

C.9

C

C C C

C

CC

CC

C

C

CC

C

C

C C C

CCCC

C

C

C C C

CC

C C C

C

C

CCC

T-401 F1

D3

D4

5.94.7

C

136136

E.B

5.3

V

V

V V

V

VV

V

V

V

V

V

V

D5

M M M M M M

MMMMMM

M M M M MM

M M M M M M M M

MM

MMMMMMMM

M M M M M M M M

MMMMMM

MMMMMM

MMM M M MMM

MM

M M

154154

T-401 A4

C

C

135 136136

136136

M

M

M

M

M

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M

AX

W

EL

L

AI

R F

O R

C E

BA

SE

, A

LA

BA

M

A

Louisville District ®

M

AR

K D

ES

C

R

IP

TI

O

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

2x

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D R

AW

IN

G C

O D

E.

N

O

VE

M

BE

R

E.

O

LN

ES

S

FI

LE

N

AM

E:

LO

U

IS

VI

LL

E

D

IS

TR

IC

T M

AX

W

EL

L

AI

R

F O

R C

E

BA

SE

JA

C

O

BS

E N

G

IN

EE

R

IN

G

G R

O U

P

IN

C

M ai n St re et

, F or t W or th , T

X

JA

C

O

BS

N o.

F 8Z

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA B

B

B1455

T-103

PA

R

TI

AL

F

LO

O R

P

LA

N

LE

VE

L

-A R

EA

B

S.

LE

FF

LE

R

S.

LE

FF

LE

R

C .M

EA

D

E

SX

H

T2

1T

-1

KEYNOTES

118 COORDINATE INSTALLATION WITH ELEVATOR

CONTRACTOR.

135 EXISTING TR MUST NOT BE USED FOR NEW NIPR

CABLING. (TYPICAL FOR UNSECURE AREA).

136 PROVIDE CABLE RACEWAY OUTLET PLATE FOR

SYSTEMS FURNITURE. (TYP)

152 DATA OUTLET FOR POWER MONITORING. COORDINATE

INSTALLATION AND FINAL LOCATION WITH ELECTRICAL

CONTRACTOR.

154 DATA OUTLETS FOR ACCESS CONTROL SYSTEM AND

INTRUSION DETECTION SYSTEM. MOUNT AT 6'-0" AFF.

1/8" = 1'-0"A1 PARTIAL FLOOR PLAN - LEVEL 1 - AREA B

GENERAL NOTES - TELECOM

A SEE SHEET T-001 FOR GENERAL NOTES AND SYMBOLS

B SEE SHEET G-003 FOR ABBREVIATIONS

C ALL NIPR AND SIPR CABLING WILL ORIGINATE FROM TR

119. ALL COMMERCIAL CABLING WILL ORIGINATE FROM

COMMERCIAL CABINETS IN ROOMS 105 AND 201

AM

EN

D

M

EN

T #1

J

AN

AM

EN

D M

EN

T

#1

J

AN

W

2Q R

R

_P la ns _0

E.1

E.A

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.2

M A

T C

H L

IN

E

A

A E

TOOL ROOM

EDS

EDS

COMPUTER

125A

AIE PTT

IAST

OFT

OFT

OFT

COMPUTER

MULTI-PURPOSE

MULTI-PURPOSE

.A

.B

A

EQ 4' - 0" EQ

4' - 0"

3' - 4"

5' - 7"

10' - 0"

13' - 2"

7' - 0" 4' - 4" 4' - 0"

3' - 4"

7' - 3" 36' - 0" 7' - 3"

2.1

M A

T C

H L

IN

E

A

A E

140140

142142

143143

144144

144144

144144

144144

A6-1A

A6-1A A6-A

A6-1

A6-1

A6 A6

A6-1

FEB

045045

A-503

D4 A-502

C6

A-502

C8

A-503

F1

F2

101A

C

2' - 1" 15' - 2"

F2

2' - 0"2' - 0"

197197

F6

A1 A-545

A4

A-545

D1

A-545

A1

A-545

A4 A-545

D1

A-545

16' - 6 1/2" 6' - 0" 35' - 0"

FEB

ACCESS FLR

14' - 6"

ACCESS FLR

14' - 6"

A3 A-311

/4

/4

/4

/4

A4

A-545

2' - 6"

9' - 2"

F3

1' - 10" 11' - 4"

A C

C E

S S

F L R

V

IF

4"

ACCESS FLR

11' - 0"

A1

A-545

A4

A-545

24' - 0"

6" 6"

LEGEND

NEW 1 HOUR FIRE RATED PARTITION

EXISTING 1 HOUR FIRE RATED PARTITION

GLAZING TYPE; RE: A-575E1

A6-A PARTITION TYPE; RE: A-570

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L

A

IR

F O

R C

E B

A S

E

A L A

B A

M A

Louisville District ®

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E M

B E

R

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA A

A

B1455

AE102

P A

R T

IA

L F

L O

O R

P L A

N

L E

V E

L

A

R E

A A

J P

E R

R Y

J M

C K

IN

N

E Y

M H

O L L E

B

S X

H T

A

E

1/8" = 1'-0"A1

PARTIAL FLOOR PLAN - LEVEL 1 - AREA A

A PARTITIONS TO BE "A6-A" UNLESS OTHERWISE NOTED.

"A6-A" WALL TYPE TO INCLUDE 6" METAL STUD, SOUND

ATTENUATION INSULATION (STC 45) AND 1 LAYER OF 5/8"

GYPSUM BOARD ON EACH SIDE.

B DOOR FRAMES ARE LOCATED 6" FROM FACE OF FINISH ON

ADJACENT PERPENDICULAR WALL U.O.N.; EXCEPT IN THE

CASE OF CORRIDORS WHERE THE DOOR IS CENTERED

WITHIN THE END WALL OF CORRIDOR OR VESTIBULE

C PROVIDE STUD INFILL AND PAINTED GYPSUM BOARD

FINISH AT ALL EXTERIOR WALLS IN ADMINISTRATION

AREAS

D EXTERIOR FINISHES AT AREAS OF NEW CONSTRUCTION

ARE TO MATCH THE EXISTING FINISHES; CONTACT 42 CES

FOR ADDITIONAL INFORMATION

E ALL OF THE METAL DECK AND STEEL STRUCTURE ON THE

EAST SIDE OF THE EXISTING HANGAR AREA THAT

SUPPORT THE NEW LEVEL 2 FLOOR SLAB ARE TO BE FIRE

RATED. WITHIN THIS AREA, ALL CONCEALED STRUCTURAL

BEAM AND METAL DECKING ARE TO HAVE SPRAY APPLIED

CEMENTITIOUS FIREPROOFING AND ALL EXPOSED

STRUCTURAL STEEL BEAM AND METAL DECKING ARE TO

HAVE INTUMESCENT EPOXY FIRE PROTECTIVE COATING.

F ALL OF THE METAL DECKING AND STEEL STRUCTURE

SUPPORTING THE MECHANICAL MEZZANINE IS TO HAVE

SPRAY APPLIED CEMENTITIOUS FIREPROOFING

G FIRE RATING OF THE LEVEL 2 FLOOR STRUCTURE AS

NOTED IN GENERAL NOTES E AND F ARE TO HAVE A

TESTED AND APPROVED RATING THAT MATCHES THE FIRE

RATING OF THE WALLS ENCLOSING THIS AREA PER NFPA

101 AND TSFPEWG

H PROVIDE FIRE RETARDANT BLOCKING WITHIN WALLS FOR

THE SECURE ATTACHMENT OF ALL WALL MOUNTED ITEMS,

INCLUDING BUT NOT LIMITED TO: TOILET ACCESSORIES,

GRAB BARS, FLAT PANEL DISPLAYS, VISUAL DISPLAYS /

MARKER BOARDS, HANDRAILING, SHELVING, AND

SUPPORTS AS REQUIRED.

GENERAL NOTES

KEYNOTES

197 BID OPTION 1: EXTERIOR STAIR FOR ACCESS TO MECHANICAL

MEZZANINE; REFER TO SHEET A-424 FOR ADDITIONAL

INFORMATION

201 CONCRETE UTILITY TRENCH WITH REMOVABLE STEEL COVER;

COORDINATE FINAL ROUTING OF TRENCH AND ACCESS TO

EQUIPMENT WITH USACE/GOVERNMENT REPRESENTATIVE PRIOR

TO BEGINNING CONSTRUCTION OF TRENCHES, INCLUDING THE

PURCHASING OF MATERIALS, AS REQUIREMENTS MAY HAVE

CHANGED

203 24"x24" RAISED ACCESS FLOORING SYSTEM

204 EMERGENCY EYE WASH; RE: PLUMBING

209 REFER TO TELECOM FOR LAYOUT OF DATA CABINETS

219 DOOR INCLUDED WITH OFT LIGHT TIGHT ENCLOSURE ASSEMBLY

235 RELOCATED MEZZANINE ACCESS LADDER; FASTEN TO CMU WALL

SIMILAR TO EXISTING INSTALLATION; PAINT TO MATCH NEW

GUARDRAIL SYSTEM

238 REPLACE EXISTING HANGAR DOOR SAFETY EDGE AND PROVIDE

NEW SAFETY EDGE

KEYNOTES

026 TACK WELD EXISTING DOOR SHUT; REPAINT DOOR FRAME AS

REQUIRED TO CONCEAL WELD MARKS

045 REMOVE EXISTING DOOR AND FRAME AND REPLACE WITH NEW

WALL INFILL TO MATCH EXISTING WALL ASSEMBLY

140 CHILLER; REFER TO MECHANICAL

141 MANUAL OPERABLE FOLDING PANEL PARTITION; RE: D1/A-510 FOR

TRACK DETAIL

142 LINEWORK INDICATES APPROXIMATE BOUNDARY OF ALTERNATE

INSERTION EXTRACTION PART TASK TRAINER (AIE-PTT);

COORDINATE FINAL LOCATION WITH USACE/GOVERNMENT

REPRESENTATIVE

143 LINEWORK INDICATES APPROXIMATE BOUNDARY OF INTEGRATED

AIRCREW SYSTEM TRAINER (IAST); COORDINATE FINAL LOCATION

WITH USACE/GOVERNMENT REPRESENTATIVE

144 PRE-MANUFACTURED LIGHT TIGHT ENCLOSURE/OFT LIGHT TIGHT

ASSEMBLY, GFGI

190 REPLACE EXISTING HANGAR DOOR GASKETING TO PROVIDE

WEATHER TIGHT SEAL

A

M E

N D

M E

N T

/2

/2

A

M E

N D

M E

N T

/2

/2

R E

G

IS

T

ERED ARCH

IT

E

C T

S T

A T

E

O F T EX

A S

1 6 5 9 2

R

IC

H A

RD

G . PERRY

J

R

12 AUG 2022

W

2Q R

R

_P la ns _0

EP103
SD102
T-103
AE102