W912QR23R0003_Plans_0001.pdf
PDF 4 MB Posted
- Solicitation number
- W912QR23R0003
About this file
This solicitation is for renovation work at Maxwell Air Force Base in Alabama. The project scope involves repairs to Aircraft Maintenance Building 1455 to support beddown of the MH-139 helicopter fleet. The estimated construction cost is between $5 million and $10 million. A site visit is scheduled for January 10, 2023 at 9:30am Central Time, with a request for interested contractors to submit personnel details by January 4, 2023 to facilitate base access. The solicitation is full and open with a best value tradeoff source selection. The procurement includes a 10% price evaluation preference for HUBZone small businesses. The NAICS code is 236220 with a size standard of $39.5 million. The solicitation number is W912QR23R0003.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4 4 4
4S
S
S
S
A V
A V
A V
A V
A V A V
A VA V
4 4
4 4
4 4
+48"
+48"
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2 2
JJJJJJ
J
JJJ
J
JJJ
JJ
JJJJJJ
J
J
J
J
J
J J
JJ
J
J
J
J JJ J
E.A
E.A.8
E.B.5
E.D.2
E.D.4
E.D.5
E.D.1
E.3
E.4
E.5
E.6
E.C
E.D
E.E
E.F
E.G
E.F.1
E.F.9
M A
T C
H L
IN
E
A
E P
GFI
GFIGFI
GFI
GFI
GFI
2.1 2.2 2.3 2.4 2.5 2.6
B.1
B.2
B.4
C.1
C.9
MH1
TX-ML1
ML1
TX-R1
R1
TX-TR1
R1BR1AHL1
AIE PTT
TELECOM
MULTI-PURPOSE
MULTI-PURPOSE
CLASSROOM
CLASSROOM
TRS
STUDENT
WORK AREA
MEN'S RR
WOMEN'S RR
VESTIBULE
CORRIDOR
FIRE ROOM
WPT
105A
ADMINISTRATION
105E
OFFICE
105D
OFFICE
105C
OFFICE
105B
WELLNESS
ADMINISTRATION
BREAK ROOM
JANITOR'S
REGISTRARS
102A
REGISTRARS OFFICE
S02
STAIR 2
GFI
GFI
GFI
GFI
GFI
TR1
GFI
ELECTRICAL
CPT
TX-BOEING
OFT
CKT BKR
BOEING PDU
GFI
FCU-4
FCU-5
FCU-3
VAV-1-04
VAV-1-06
VAV-1-11
VAV-1-12
VAV-1-10
VAV-1-14
VAV-1-07104 104
105 105
36"X30"X8"
J-BOX
AMRS METER
GEN CONN
CAB
R1C
SEC-DOOR-1
FMCP
SEC-DOOR-2
SEC-ACS
SEC-IDS
GFI/WP
VAV-1-08
VAV-1-09
VAV-1-13
128128
IAST-DISC
AIE PTT-DISC
E-401
F5
E-401
A1
115A
STORAGE
110A
CORRIDOR
IAST
S01
STAIR 1
CORRIDOR
AIE PTT
-12R1C
-13R1C
-15R1
-6R1A
-24R1A
-1R1A
-31R1A
-13R1A
-4R1A
-7R1A
-3R1A
-25R1A
040040
E-401
A4
-8R1A
-21R1A
-18R1A -19R1A
-27R1A
-26R1A
-23R1A
-1FA
-12ML1
-15R1A
-14R1A-2,4,6,35R1D
-6ML1
-7,9,11MH1
-5R1
-1R1B
-7,9,11,39R1D
-1,3,5,36R1D
-8,10,12,37R1D
-15TR1
138-9R1C
-16,18,20,38R1D
-22,24,26,41R1D
-5R1A
-17R1A
GFI/WP
-10ML1
-9,11R1
FCU-6 FCU-7
-19ML1
-21ML1
-13R1
MICROWAVE
COFFEE
DISHWASHER
040040
R1D
-1R1C
-3R1C
-1,3R1
-8,10R1
PROPOSED NEW CRANE
DISCONNECT LOCATION
-4R1C
-13,14,15,34R1D
-2FA
059 059
-5ML1
EF-5
-16R1A
-22R1A
-30,32,34,36R1A
109 109
TRUE N
PLAN
NORTH
TRUE N
164 8268
SCALE: 1/8"=1'-0"
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
US Army Corps of Engineers
R E
P A
IR
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
B F
O R
M H
-1
M A
X W
E L L A
IR
F
O R
C E
B A
S E
A
L A
B A
M A
Louisville District ®
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
D R
A W
IN
G
C O
D E
A
U G
E O
L N
E S
S F
IL
E
N A
M E
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
M A
X W
E L L
A
IR
F O
R C
E B
A S
E
J
C O
B S
E N
G
IN
E E
R
IN
G G
R O
U P
I N
C
M a in
S tr e e t, F o rt
W o rt h
T X
J A
C O
B S
N o
F Z
CERTIFIED FINAL DESIGN
P R
O J E
C T
N U
M B
E R
P
N Q
S B
P
GRAPHIC SCALE
KEY PLAN
AREA B
B
B1455
EP103
P A
R T
IA
L P
O W
E R
P L A
N
L E
V E
L
A
R E
A B
A M
C W
H O
R T
E R
A F
O R
M A
N
K .H
O G
A N
S X
H T
E
P
KEYNOTES
040 PROVIDE REMOTE INDICATOR AND RESET GFCI IN AN
ACCESSIBLE LOCATION. PROVIDE LABEL IDENTIFYING THE
APPLIANCE SERVED.
059 PROVIDE POWER CONNECTION TO DOOR HOLD OPEN.
COORDINATE REQUIREMENTS WITH MANUFACTURER AND FIRE
PROTECTION.
101 REMOVE EXISTING CRANE DISCONNECT AND PROVIDE NEW
DISCONNECT IN NEW LOCATION. EXTEND CONDUIT AND
CONDUCTORS TO NEW LOCATION. PROVIDE CRANE
DISCONNECT RELOCATION MEETING WITH CONTRACTING
OFFICER AND USERS TO DETERMINE IDEAL LOCATION FOR THE
CRANE DISCONNECT SWITCH. REMOVE EXISTING CRANE
DISCONNECT AND PROVIDE NEW DISCONNECT SWITCH IN
LOCATION PER THE RELOCATION MEETING. PROVIDE TESTING
AND COMMISSIONING OF CRANE PRIOR TO START OF
CONSTRUCTION. CRANE IS TO REMAIN OPERATIONAL AFTER
CONSTRUCTION COMPLETION. TEST AND COMMISSION CRANE
AFTER RELOCATION OF CRANE DISCONNECT AND CONTROLS.
PROVIDE NEW DISCONNECT AND CIRCUIT TO MATCH EXISTING.
104 PROVIDE SURFACE-TYPE FLOOR BOX WITH COMBINATION
POWER AND DATA. PROVIDE DUPLEX 5-20R RECEPTACLE AND
SPACE FOR DATA. REFER TO TELECOM PLANS. COORDINATE
WITH ARCHITECTURAL AND INTERIORS FOR DIMENSIONS TO
LOCATE BELOW TABLES.
105 PROVIDE IN-CARPET EXPOSED RACEWAY SYSTEM FROM THE
WALL TO THE FLOOR BOX.
107 PROVIDE UNDERGROUND CONDUITS FROM TRANSFORMER TO
EXTERIOR JUNCTION BOX FOR SERVICE CONDUCTORS TO
MDP2. COORDINATE WITH THE LOCAL ELECTRICAL UTILITY
COMPANY (CAEC) TO INSTALL THE CONDUITS INTO THE
SECONDARY SECTION OF THE TRANSFORMER.
109 PROVIDE A 10-WIRE (4-4-2), 2+2 CIRCUIT CONFIGURATION TO
THE WORKSTATIONS. PROVIDE 8#10, 2#10 GROUND IN 1-1/4"
CONDUIT AND MAKE WHIP CONNECTION TO FURNITURE
ACCORDING TO FURNITURE MANUFACUTURER REQUIREMENTS.
ONE DUPLEX OUTLET SHALL HAVE CONTROLLED
RECEPTACLES AND THE THREE OTHER DUPLEX OUTLET WILL
HAVE NON-SWITCHED RECEPTACLES. LABEL CONTROLLED
RECEPTACLES ACCORDINGLY. COORDINATE WITH FURNITURE
MANUFACTURER TO PROVIDE ELECTRICAL CONNECTIONS AND
TESTING OF FURNITURE RECEPTACLES.
120 MOUNT THE SWITCH IN ELEVATORT PIT AT REACHING HEIGHT
NEAR ELEVATOR OPENING.
128 PROVIDE TWO 2-POLE 3-WIRE 208 VAC OUTLET FOR THE
COCKPIT PROCEDURAL TRAINER (CPT).
129 PROVIDE A DEDICATED DUPLEX OUTLET FOR THE WEAPONS
PROCEDURAL TRAINER (WPT).
130 PROVIDE A L5-20P PLUG FOR THE WEAPONS PROCEDURAL
TRAINER (WPT).
135 PROVIDE A DISCONNECT FOR THE IAST TOWARDS THE REAR
OF THE TRAINER.
136 PROVIDE A DISCONNECT FOR THE ALTERNATE INSERTION
EXTRACTION PART-TASK TRAINER (AIE PTT) AT THE BOTTOM OF
THE SCAFFOLD SYSTEM.
138 PROVIDE RECEPTACLES FOR TELECOMMUNICATIONS RACK.
COORDINATE MOUNTING LOCATIONS WITH TELECOM
DRAWINGS.
1/8" = 1'-0"A1
PARTIAL POWER PLAN - LEVEL 1 - AREA B
GENERAL NOTES - POWER
A REFER TO A2/E-501 FOR CONTROLLED RECEPTACLES WIRING
DIAGRAM.
B REFER TO E-602 FOR ADDITIONAL EQUIPMENT CONNECTION
INFORMATION. FOR INTEGRAL DISCONNECTS, REFER TO
EQUIPMENT SCHEDULES AND MECHANICAL SHEETS. INTEGRAL
DISCONNECTS ARE SHOWN AS HALF-TONED.
C CONDUIT RUNS AS SHOWN ON THE PLANS ARE DIAGRAMMATIC
ONLY. EXACT LOCATION AND METHOD OF SUPPORT MUST BE
DETERMINED IN THE FIELD.
E PROVIDE SOURCE (PANEL & CIRCUIT #) LABEL ON ALL NEW
RECEPTACLE COVERS.
A
M E
N D
M E
N T
-0
-2
A M
E N
D M
E N
T
-0
-2
AARON McWHORTER
100310
L I C ENS ED
P R
O
F
ESS IONA L ENG
IN
E E
R
S TATE OF TEXA
S
TEXAS REGISTERED
ENGINEERING FIRM F-2966
12 AUG 2022
W
2Q R
R
_P la ns _0
E.1
E.A
E.A.8
E.B.5
E.C.4
E.D.2
E.D.4
E.2
29' - 4"
/4
/4
/4
/4
A1
S-301
114114
84' - 8"
CL OF HANGAR
19' - 8" 19' - 10 7/8"
14" THICK EXISTING CONCRETE SLAB
9" THICK EXISTING
CONCRETE SLAB
9" THICK EXISTING
CONCRETE SLAB
121TYP
M
IN
M
IN
M
IN
TRUE N
PLAN
NORTH
TRUE N
164 8268
SCALE: 1/8"=1'-0"
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
US Army Corps of Engineers
R E
P A
IR
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
B F
O R
M H
-1
M A
X W
E L L A
IR
F
O R
C E
B A
S E
A
L A
B A
M A
Louisville District ®
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
D R
A W
IN
G
C O
D E
N
O V
E M
B E
R
E O
L N
E S
S
F
IL
E N
A M
E
L O
U
IS
V
IL
L E
D
IS
T R
X W
E L L
A
IR
F O
R C
E B
A
C O
B S
E N
G
IN
E E
R
IN
G G
R O
U P
I N
C
M a in
S tr e e t, F o rt
W o rt h
T X
J A
C O
B S
N o
F Z
CERTIFIED FINAL DESIGN
P R
O J E
C T
N U
M B
E R
P
N Q
S B
P
GRAPHIC SCALE
KEY PLAN
AREA A
A
B1455
SD102
P A
R T
IA
L D
E M
O L
IT
IO
N
L
V E
L
A
R E
A A
A B
A N
N E
R O
T
D O
R T
O N
A S
A V
O
IE
S X
H T
S
D
1/8" = 1'-0"A1
PARTIAL DEMOLITION PLAN - LEVEL 1 - AREA A
SHEET NOTES - DEMOLITION PLAN
A FIELD VERIFY EXISTING DIMENSIONS, MEMBER SIZES,
ELEVATIONS AND OTHER CONDITIONS. NOTIFY
CONTRACTING OFFICER OF ANY DISCREPANCIES TO
RECEIVE REVISED RECOMMENDATIONS..
B VERIFY LOCATIONS OF ALL UNDERGROUND AND
ABOVE GROUND UTILITIES PRIOR TO START OF
CONSTRUCTION. REPAIR, REROUTE, OR REPLACE
UTILITIES AS REQUIRED TO PERFORM NEW
CONSTRUCTION.
C INSTALL REINFORCING CHANNELS AROUND NEW
OPENINGS PRIOR TO ENLARGING OPENINGS. RE: WALL
ELEVATIONS.
KEYNOTES
106 EXISTING MASONRY WALL
112 SAWCUT AND REMOVE EXISTING SLAB FOR NEW
CONCRETE FOOTING
114 NEW OPENING IN EXISTING CMU WALL REFER TO
ELEVATION
119 EXISTING TENSION ROD ENCASEMENT. MUST REMAIN
UNDISTURBED. PROCEED WITH EXTREME CAUTION
WHEN CUTTING EXISTING SLAB NEAR GRID LINES E.A.8,
E.B.5 & E.C.4 TO AVOID EXISTING TENSION RODS AND
ENCASEMENT. DO NOT CUT WITHIN 12" EITHER SIDE
OF THESE GRID LINES.
121 EXISTING STEEL COLUMN
A M
E N
D M
E N
T
J
A N
ALEX BANNEROT
OF TEXASS
TATE
ALNOI
SS
E
F O
R P
ENG
IN
E E
R
NSEDECI
L 91686
12 AUG 2022
W
2Q R
R
_P la ns _0
4 4 4
4S
S
S
S
A V
A V
A V
A V A V A V
A VA V4 4
4 4
4 4
+48"
+48"
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2 2
E.A
E.A.8
E.B.5
E.C.4
E.D.2
E.D.4
E.D.5
E.D.1
E.3
E.4
E.5
E.6
E.C
E.D
E.E
E.F
E.G
E.F.1
E.F.9
M
AT
C
H
LI
N E
A1 T-
T-401 A1
TELECOM
FIRE ROOM
WPT
CPT
ELECTRICAL
E01
ELEVATOR
MULTI-PURPOSE
MULTI-PURPOSE
CLASSROOM
CLASSROOM 109
MEN'S RR
WOMEN'S RR
STUDENT
WORK AREA
VESTIBULE
CORRIDOR
JANITOR'S
102A
REGISTRARS OFFICE
REGISTRARS
TRS
ADMINISTRATION
105A
ADMINISTRATION
BREAK ROOM
105B
WELLNESS
105C
OFFICE
105D
OFFICE
105E
OFFICE
+72" +72"
+72" +72"
2.62.52.42.32.22.1
B.1
B.2
B.4
C.1
C.9
C
C C C
C
CC
CC
C
C
CC
C
C
C C C
CCCC
C
C
C C C
CC
C C C
C
C
CCC
T-401 F1
D3
D4
5.94.7
C
136136
E.B
5.3
V
V
V V
V
VV
V
V
V
V
V
V
D5
M M M M M M
MMMMMM
M M M M MM
M M M M M M M M
MM
MMMMMMMM
M M M M M M M M
MMMMMM
MMMMMM
MMM M M MMM
MM
M M
154154
T-401 A4
C
C
135 136136
136136
M
M
M
M
M
TRUE N
PLAN
NORTH
TRUE N
164 8268
SCALE: 1/8"=1'-0"
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
US Army Corps of Engineers
R E
P A
IR
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
B F
O R
M H
-1
M
AX
W
EL
L
AI
R F
O R
C E
BA
SE
, A
LA
BA
M
A
Louisville District ®
M
AR
K D
ES
C
R
IP
TI
O
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
2x
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D R
AW
IN
G C
O D
E.
N
O
VE
M
BE
R
E.
O
LN
ES
S
FI
LE
N
AM
E:
LO
U
IS
VI
LL
E
D
IS
TR
IC
T M
AX
W
EL
L
AI
R
F O
R C
E
BA
SE
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
M ai n St re et
, F or t W or th , T
X
JA
C
O
BS
N o.
F 8Z
CERTIFIED FINAL DESIGN
P R
O J E
C T
N U
M B
E R
P
N Q
S B
P
GRAPHIC SCALE
KEY PLAN
AREA B
B
B1455
T-103
PA
R
TI
AL
F
LO
O R
P
LA
N
LE
VE
L
-A R
EA
B
S.
LE
FF
LE
R
S.
LE
FF
LE
R
C .M
EA
D
E
SX
H
T2
1T
-1
KEYNOTES
118 COORDINATE INSTALLATION WITH ELEVATOR
CONTRACTOR.
135 EXISTING TR MUST NOT BE USED FOR NEW NIPR
CABLING. (TYPICAL FOR UNSECURE AREA).
136 PROVIDE CABLE RACEWAY OUTLET PLATE FOR
SYSTEMS FURNITURE. (TYP)
152 DATA OUTLET FOR POWER MONITORING. COORDINATE
INSTALLATION AND FINAL LOCATION WITH ELECTRICAL
CONTRACTOR.
154 DATA OUTLETS FOR ACCESS CONTROL SYSTEM AND
INTRUSION DETECTION SYSTEM. MOUNT AT 6'-0" AFF.
1/8" = 1'-0"A1 PARTIAL FLOOR PLAN - LEVEL 1 - AREA B
GENERAL NOTES - TELECOM
A SEE SHEET T-001 FOR GENERAL NOTES AND SYMBOLS
B SEE SHEET G-003 FOR ABBREVIATIONS
C ALL NIPR AND SIPR CABLING WILL ORIGINATE FROM TR
119. ALL COMMERCIAL CABLING WILL ORIGINATE FROM
COMMERCIAL CABINETS IN ROOMS 105 AND 201
AM
EN
D
M
EN
T #1
J
AN
AM
EN
D M
EN
T
#1
J
AN
W
2Q R
R
_P la ns _0
E.1
E.A
E.A.8
E.B.5
E.C.4
E.D.2
E.D.4
E.D.5
E.D.1
E.2
M A
T C
H L
IN
E
A
A E
TOOL ROOM
EDS
EDS
COMPUTER
125A
AIE PTT
IAST
OFT
OFT
OFT
COMPUTER
MULTI-PURPOSE
MULTI-PURPOSE
.A
.B
A
EQ 4' - 0" EQ
4' - 0"
3' - 4"
5' - 7"
10' - 0"
13' - 2"
7' - 0" 4' - 4" 4' - 0"
3' - 4"
7' - 3" 36' - 0" 7' - 3"
2.1
M A
T C
H L
IN
E
A
A E
140140
142142
143143
144144
144144
144144
144144
A6-1A
A6-1A A6-A
A6-1
A6-1
A6 A6
A6-1
FEB
045045
A-503
D4 A-502
C6
A-502
C8
A-503
F1
F2
101A
C
2' - 1" 15' - 2"
F2
2' - 0"2' - 0"
197197
F6
A1 A-545
A4
A-545
D1
A-545
A1
A-545
A4 A-545
D1
A-545
16' - 6 1/2" 6' - 0" 35' - 0"
FEB
ACCESS FLR
14' - 6"
ACCESS FLR
14' - 6"
A3 A-311
/4
/4
/4
/4
A4
A-545
2' - 6"
9' - 2"
F3
1' - 10" 11' - 4"
A C
C E
S S
F L R
V
IF
4"
ACCESS FLR
11' - 0"
A1
A-545
A4
A-545
24' - 0"
6" 6"
LEGEND
NEW 1 HOUR FIRE RATED PARTITION
EXISTING 1 HOUR FIRE RATED PARTITION
GLAZING TYPE; RE: A-575E1
A6-A PARTITION TYPE; RE: A-570
TRUE N
PLAN
NORTH
TRUE N
164 8268
SCALE: 1/8"=1'-0"
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
US Army Corps of Engineers
R E
P A
IR
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
B F
O R
M H
-1
M A
X W
E L L
A
IR
F O
R C
E B
A S
E
A L A
B A
M A
Louisville District ®
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
D R
A W
IN
G
C O
D E
N
O V
E M
B E
R
E O
L N
E S
S F
IL
E
N A
M E
L O
U
IS
V
IL
L E
D
IS
T R
X W
E L L
A
IR
F O
R C
E B
A
C O
B S
E N
G
IN
E E
R
IN
G G
R O
U P
I N
C
M a in
S tr e e t, F o rt
W o rt h
T X
J A
C O
B S
N o
F Z
TEXAS REGISTERED
ENGINEERING FIRM F-2966
CERTIFIED FINAL DESIGN
P R
O J E
C T
N U
M B
E R
P
N Q
S B
P
GRAPHIC SCALE
KEY PLAN
AREA A
A
B1455
AE102
P A
R T
IA
L F
L O
O R
P L A
N
L E
V E
L
A
R E
A A
J P
E R
R Y
J M
C K
IN
N
E Y
M H
O L L E
B
S X
H T
A
E
1/8" = 1'-0"A1
PARTIAL FLOOR PLAN - LEVEL 1 - AREA A
A PARTITIONS TO BE "A6-A" UNLESS OTHERWISE NOTED.
"A6-A" WALL TYPE TO INCLUDE 6" METAL STUD, SOUND
ATTENUATION INSULATION (STC 45) AND 1 LAYER OF 5/8"
GYPSUM BOARD ON EACH SIDE.
B DOOR FRAMES ARE LOCATED 6" FROM FACE OF FINISH ON
ADJACENT PERPENDICULAR WALL U.O.N.; EXCEPT IN THE
CASE OF CORRIDORS WHERE THE DOOR IS CENTERED
WITHIN THE END WALL OF CORRIDOR OR VESTIBULE
C PROVIDE STUD INFILL AND PAINTED GYPSUM BOARD
FINISH AT ALL EXTERIOR WALLS IN ADMINISTRATION
AREAS
D EXTERIOR FINISHES AT AREAS OF NEW CONSTRUCTION
ARE TO MATCH THE EXISTING FINISHES; CONTACT 42 CES
FOR ADDITIONAL INFORMATION
E ALL OF THE METAL DECK AND STEEL STRUCTURE ON THE
EAST SIDE OF THE EXISTING HANGAR AREA THAT
SUPPORT THE NEW LEVEL 2 FLOOR SLAB ARE TO BE FIRE
RATED. WITHIN THIS AREA, ALL CONCEALED STRUCTURAL
BEAM AND METAL DECKING ARE TO HAVE SPRAY APPLIED
CEMENTITIOUS FIREPROOFING AND ALL EXPOSED
STRUCTURAL STEEL BEAM AND METAL DECKING ARE TO
HAVE INTUMESCENT EPOXY FIRE PROTECTIVE COATING.
F ALL OF THE METAL DECKING AND STEEL STRUCTURE
SUPPORTING THE MECHANICAL MEZZANINE IS TO HAVE
SPRAY APPLIED CEMENTITIOUS FIREPROOFING
G FIRE RATING OF THE LEVEL 2 FLOOR STRUCTURE AS
NOTED IN GENERAL NOTES E AND F ARE TO HAVE A
TESTED AND APPROVED RATING THAT MATCHES THE FIRE
RATING OF THE WALLS ENCLOSING THIS AREA PER NFPA
101 AND TSFPEWG
H PROVIDE FIRE RETARDANT BLOCKING WITHIN WALLS FOR
THE SECURE ATTACHMENT OF ALL WALL MOUNTED ITEMS,
INCLUDING BUT NOT LIMITED TO: TOILET ACCESSORIES,
GRAB BARS, FLAT PANEL DISPLAYS, VISUAL DISPLAYS /
MARKER BOARDS, HANDRAILING, SHELVING, AND
SUPPORTS AS REQUIRED.
GENERAL NOTES
KEYNOTES
197 BID OPTION 1: EXTERIOR STAIR FOR ACCESS TO MECHANICAL
MEZZANINE; REFER TO SHEET A-424 FOR ADDITIONAL
INFORMATION
201 CONCRETE UTILITY TRENCH WITH REMOVABLE STEEL COVER;
COORDINATE FINAL ROUTING OF TRENCH AND ACCESS TO
EQUIPMENT WITH USACE/GOVERNMENT REPRESENTATIVE PRIOR
TO BEGINNING CONSTRUCTION OF TRENCHES, INCLUDING THE
PURCHASING OF MATERIALS, AS REQUIREMENTS MAY HAVE
CHANGED
203 24"x24" RAISED ACCESS FLOORING SYSTEM
204 EMERGENCY EYE WASH; RE: PLUMBING
209 REFER TO TELECOM FOR LAYOUT OF DATA CABINETS
219 DOOR INCLUDED WITH OFT LIGHT TIGHT ENCLOSURE ASSEMBLY
235 RELOCATED MEZZANINE ACCESS LADDER; FASTEN TO CMU WALL
SIMILAR TO EXISTING INSTALLATION; PAINT TO MATCH NEW
GUARDRAIL SYSTEM
238 REPLACE EXISTING HANGAR DOOR SAFETY EDGE AND PROVIDE
NEW SAFETY EDGE
KEYNOTES
026 TACK WELD EXISTING DOOR SHUT; REPAINT DOOR FRAME AS
REQUIRED TO CONCEAL WELD MARKS
045 REMOVE EXISTING DOOR AND FRAME AND REPLACE WITH NEW
WALL INFILL TO MATCH EXISTING WALL ASSEMBLY
140 CHILLER; REFER TO MECHANICAL
141 MANUAL OPERABLE FOLDING PANEL PARTITION; RE: D1/A-510 FOR
TRACK DETAIL
142 LINEWORK INDICATES APPROXIMATE BOUNDARY OF ALTERNATE
INSERTION EXTRACTION PART TASK TRAINER (AIE-PTT);
COORDINATE FINAL LOCATION WITH USACE/GOVERNMENT
REPRESENTATIVE
143 LINEWORK INDICATES APPROXIMATE BOUNDARY OF INTEGRATED
AIRCREW SYSTEM TRAINER (IAST); COORDINATE FINAL LOCATION
WITH USACE/GOVERNMENT REPRESENTATIVE
144 PRE-MANUFACTURED LIGHT TIGHT ENCLOSURE/OFT LIGHT TIGHT
ASSEMBLY, GFGI
190 REPLACE EXISTING HANGAR DOOR GASKETING TO PROVIDE
WEATHER TIGHT SEAL
A
M E
N D
M E
N T
/2
/2
A
M E
N D
M E
N T
/2
/2
R E
G
IS
T
ERED ARCH
IT
E
C T
S T
A T
E
O F T EX
A S
1 6 5 9 2
R
IC
H A
RD
G . PERRY
J
R
12 AUG 2022
W
2Q R
R
_P la ns _0
| EP103 |
| SD102 |
| T-103 |
| AE102 |
File details come from the government source that posted it. Updated .