This document provides details for a federal contract solicitation to renovate an aircraft maintenance building at Maxwell Air Force Base in Alabama. The project scope involves repairing Building 1455 to accommodate beddown of the MH-139 helicopter. The estimated construction cost is between $5-10 million. A site visit is scheduled for January 10, 2023 at 9:30am Central Time. Interested parties must submit personal information for base access to Dan Corrigan by January 4, 2023 via email or phone. The solicitation number is W912QR23R0003, issued by the Department of the Army Corps of Engineers Engineering District Louisville. The NAICS code is 236220 for commercial construction of buildings, with a size standard of $39.5 million. This is a full and open competition using best value tradeoff procedures.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation For Repair Aircraft Maintenance B1455 for MH-139, Maxwell AFB, AL

P2: 496395

Design-Bid-Build

Specifications - SID Certified Final Design

29 December 2022

W912QR23R0003

ARIMS: 200A

Disposition: Maintain for 15yrs after construction

W912QR23R0003_SID-0000

TABLE OF CONTENTS

STRUCTURAL INTERIOR DESIGN

Design Narrative Tab 1

Finish Plans Tab 2

Finish Material Legend / Room Finish Schedule Tab 3

Signage Plans, Details & Schedule Tab 4

Interior Elevations & Details Tab 5

Furniture Footprint Plans Tab 6

Reflected Ceiling Plans Tab 7

Interior Finish Boards Tab 8

DESIGNER OF RECORD:

JACOBS

777 MAIN STREET, FORT WORTH, TX 76102

CONTACT: JERI CHAMPINE

MAXWELL AIR FORCE BASE, ALABAMA

REPAIR AIRCRAFT MAINTENANCE B1455 FOR

MH-139

PROJECT NUMBER: PNQS21B1455, P2#: 496395

FY21 Repair Aircraft Maintenance B1455 For MH-139 Maxwell AFB, AL

PREPARED BY: Machelle Above

DATE: November 23, 2022

SUBJECT: Interior Design Narrative

Codes, Standards, and Regulations

• ANSI/BIFMA Safety and Performance Standards for Furniture (2011)

• ASTM D 2047; Test for Slip Resistance of Hard Surfaces

• ETL 07-4 – Air Force Carpet Standard

• NFPA 260 – Methods of Tests and Classification System for Cigarette Ignition Resistance of Components (2009)

• NFPA 261 – Method of Test for Determining Resistance of Mock-up Upholstered

Furniture Material Assemblies to Ignition by Smoldering Cigarettes (2009)

• NFPA 705 – Field Flame Test for Textiles and Films

• UFC 3-120-01 – Design, Sign Standards, with Change 3, 12 Dec 2017

• UFC 3-120-10 – Interior Design (2018)

• Wyzenbeek Abrasion Resistance Test

• Air Force Reserve Command Handbook 32-1001

General This project involves the renovation of the Repair Aircraft Maintenance Hanger, B1455 located at Maxwell

Air force Base, AL. Included in the renovation is the existing hanger administration spaces. Additionally, the project includes a newly constructed admin space with supporting classrooms, mission planning space, administrative areas, and other support spaces.

Comprehensive Interior Design

The Comprehensive Interior Design (CID) package includes Structural Interior Design (SID) and Furniture, Fixture & Equipment (FF&E). The goal of the CID is to provide a functional, durable, visually appealing facility to enhance the User’s working environment. Finishes in the SID and FF&E package are coordinated to create a unified, cohesive facility.

Structural Interior Design

Structural interior design includes all building finishes, built-in casework, window coverings, and signage.

Administrative and training areas will receive carpet tile flooring with resilient base, painted gypsum board walls, and acoustical ceiling tile.

Corridors will receive LVT flooring and resilient base. Walls are a light neutral color. Corridor ceilings have a combination of high NRC white acoustical tile with a few painted gypsum board soffits.

Wall protection will include corner guards at all outside corners throughout the facility.

Window shades are used throughout the facility except at entry vestibules and corridors.

Restrooms will receive porcelain tile flooring and walls, metal cove base, and moisture resistant painted gypsum board ceilings. Toilet compartments will be durable solid core phenolic. Lavatories will have solid surface countertops with a removable plastic laminate apron panel.

The break room will receive LVT flooring and resilient base, painted gypsum board walls, and acoustical ceiling tile. Casework will be plastic laminate with solid surface countertops and porcelain mosaic tile backsplash.

Simulator areas will have epoxy flooring and utility areas such as electrical/ mechanical rooms will have sealed concrete floors, resilient base, painted gypsum board walls, and painted open structure above. The telecommunication room will have the same finishes except with static control flooring. Janitor’s closets will have sealed concrete flooring with resilient base, a water-resistant wainscot with paint above, and painted open structure ceilings.

Furniture, Fixtures, & Equipment (Bid Option)

FF&E for this project is a bid option and includes freestanding modular desk systems, systems furniture with powered and non-powered panels, storage, seating, and tables. All desks and workstations will have trash and recycle bins. Desks and workstations will have plastic laminate worksurfaces with painted metal storage units.

The General Contractor is responsible for all electrical connections from the FF&E to the building.

Government furnished equipment for this project includes break room appliances, flat screen TV monitors with wall brackets, and copiers/printers.

E.1

E.A

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.2 E.3

E.4 E.5

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

5.3

D4

EDS

COMPUTER

125A

MULTI-PURPOSE

MULTI-PURPOSE

AIE PTT

TOOL ROOM

CPT

WPT

TELECOM

FIRE ROOM

MULTI-PURPOSE

MULTI-PURPOSE

STAIR 1

S01

STUDENT

WORK AREA

CORRIDOR

VESTIBULE

REGISTRARS

OFFICE

102A

REGISTRARS

ADMINISTRATION

ADMINISTRATION

105A

WELLNESS

105B

OFFICE

105C

OFFICE

105D

OFFICE

105E

WOMEN'S RR

MEN'S RR

BREAK

ROOM

JANITOR'S

CLASSROOM

CLASSROOM

EDS

IAST

ELECTRICAL

B.1

B.2

B.3

B.4

C.1

C.9

E 6

E A

D3

4.7

ED.5

CIRCULATION

OFT

OFT

OFT

COMPUTER

TRS

104CORRIDOR

110B

ELEVATOR

E01

CORRIDOR

110A

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

8 16 3241216

SCALE: 1/16"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

M A

X W

E L L

A

IR

F O

R C

E B

A S

E

J

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

OVERALL

BA

B1455

23 NOV 2022

IN101

O V

E R

A L L F

IN

IS

H P

L A

N

L E

V E

L

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

1/16" = 1'-0"A1

OVERALL FINISH PLAN - LEVEL 1

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.2

M A

T C

H L

IN

E

A

IN

EDS

COMPUTER

125A

EDS

AIE PTT

MULTI-PURPOSE

MULTI-PURPOSE

TOOL ROOM

B.1

B.2

B.3

B.4

C.1

C.9

2.1

IAST

CIRCULATION

OFT

OFT

OFT

COMPUTER

I-201

A5

196196

FLOOR FINISH LEGEND

CPT-1

CPT-2

EXC-1

LVT-1

PFT-1

SC-1

SDT-1

RAF-1

RF-1

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA A

A

B1455

23 NOV 2022

IN102

P A

R T

IA

L F

IN

IS

H P

L A

N

L E

V E

L

A

R E

A A

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

1/8" = 1'-0"A1

PARTIAL FINISH PLAN - LEVEL 1 - AREA A

KEYNOTES

119 PAINT PT-2.

196 TRENCH - STEEL COVER PLATE

GENERAL NOTES - FINISH PLANS

A FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING

MATERIALS/FINISHES.

B REFER TO I-601 FOR FINISH LEGEND AND I-602 FOR ROOM

FINISH SCHEDULE.

C ALL TRANSITIONS ARE TO OCCUR AT THE CENTERLINE

OF THE DOOR, DOORWAY OR CEILING LINE, UNLESS

OTHERWISE NOTED.

D REFER TO REFLECTED CEILING PLANS ON AE121 TO

AE133 FOR ADDITIONAL INFORMATION.

E APPLY BASE AS SPECIFIED ON ALL WALL TYPES.

F CORNER GUARDS ARE REQUIRED ON ALL OUTSIDE

CORNERS

G PAINT EXISTING HANGAR WALLS PT-3

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.3

E.4

E.5

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

M A

T C

H L

IN

E

A

IN

2 I-201

A1

ELECTRICAL

CPT

ELEVATOR

E01

STAIR 1

S01

WPT

TELECOM

FIRE ROOM

MULTI-PURPOSE

CLASSROOM

CLASSROOM

MULTI-PURPOSE

STUDENT

WORK AREA

MEN'S RR

WOMEN'S RR

ADMINISTRATION

ADMINISTRATION

105A

WELLNESS

ROOM

105B

OFFICE

105C

OFFICE

105D

OFFICE

105E

BREAK

ROOM

JANITORS

REGISTRARS

CORRIDOR

REGISTRARS

OFFICE

102A

VESTIBULE

TRS

I-202

A1

119119

119119

119119

B.1

B.2

B.3

B.4

C.1

C.9

2.6 E 6

2.52.1 2.2 2.3 2.4

132132

132132

119 119

D4

D3

4.7

119119119

I-201

A3

I-203

A1

132132 132132

STORAGE

115A

119119

CORRIDOR

119119

CORRIDOR

110B

CORRIDOR

110A

FLOOR FINISH LEGEND

CPT-1

CPT-2

EXC-1

LVT-1

PFT-1

SC-1

SDT-1

RAF-1

RF-1

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA B

B

B1455

23 NOV 2022

IN103

P A

R T

IA

L F

IN

IS

H P

L A

N

L E

V E

L

A

R E

A B

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

KEYNOTES

119 PAINT PT-2.

132 INSTALL WS-1 WINDOW SHADE AT EXTERIOR

WINDOWS, UON.

134 STAIR TREADS/ RISERS RF-1. PAINT HANDRAILS PT-4.

196 TRENCH - STEEL COVER PLATE

1/8" = 1'-0"A1

PARTIAL FINISH PLAN - LEVEL 1 - AREA B

GENERAL NOTES - FINISH PLANS

A FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING

MATERIALS/FINISHES.

B REFER TO I-601 FOR FINISH LEGEND AND I-602 FOR ROOM

FINISH SCHEDULE.

C ALL TRANSITIONS ARE TO OCCUR AT THE CENTERLINE

OF THE DOOR, DOORWAY OR CEILING LINE, UNLESS

OTHERWISE NOTED.

D REFER TO REFLECTED CEILING PLANS ON AE121 TO

AE133 FOR ADDITIONAL INFORMATION.

E APPLY BASE AS SPECIFIED ON ALL WALL TYPES.

F CORNER GUARDS ARE REQUIRED ON ALL OUTSIDE

CORNERS

G PAINT EXISTING HANGAR WALLS PT-3

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.2 E.3

E.4

E.5

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

5.3

D4

MECH MEZZ

MISSION

PLANNNG

MISSION

PLANNING

CLASS

CORRIDOR

200A

STAIR 1

S01

TSC

B.1

B.2

B.3

B.4

C.1

C.9

E 6

E A

E.B

D4

D3

4.7

ED.5

COMM

CLOSET

CORRIDOR

200B

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

8 16 3241216

SCALE: 1/16"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

OVERALL

BA

B1455

23 NOV 2022

IN111

O V

E R

A L L F

IN

IS

H P

L A

N

L E

V E

L

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

1/16" = 1'-0"A1

OVERALL FINISH PLAN - LEVEL 2

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.3

E.4

E.5

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

MISSION

PLANNING

CLASS

STAIR 1

S01

TSC

COMM

CHASE

MISSION

PLANNNG

ELEVATOR

E01

CORRIDOR

200A

119119 119119

119119

119119

B.1

B.2

B.3

B.4

C.1

C.9

2.6 E 6

2.52.1 2.2 2.3 2.4

D4

D3

4.7

I-201

D6 Sim

I-201

F1 Sim

I-201

F1 Sim

FLOOR FINISH LEGEND

CPT-1

CPT-2

EXC-1

LVT-1

PFT-1

SC-1

SDT-1

RAF-1

RF-1

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA B

B

B1455

23 NOV 2022

IN112

P A

R T

IA

L F

IN

IS

H P

L A

N

L E

V E

L

A

R E

A B

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

1/8" = 1'-0"A1

PARTIAL FINISH PLAN - LEVEL 2 - AREA B

KEYNOTES

119 PAINT PT-2.

134 STAIR TREADS/ RISERS RF-1. PAINT HANDRAILS PT-4.

185 RAF-1 FLOORING AT RAMP AND LANDING.

GENERAL NOTES - FINISH PLANS

A FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING

MATERIALS/FINISHES.

B REFER TO I-601 FOR FINISH LEGEND AND I-602 FOR ROOM

FINISH SCHEDULE.

C ALL TRANSITIONS ARE TO OCCUR AT THE CENTERLINE

OF THE DOOR, DOORWAY OR CEILING LINE, UNLESS

OTHERWISE NOTED.

D REFER TO REFLECTED CEILING PLANS ON AE121 TO

AE133 FOR ADDITIONAL INFORMATION.

E APPLY BASE AS SPECIFIED ON ALL WALL TYPES.

F CORNER GUARDS ARE REQUIRED ON ALL OUTSIDE

CORNERS

G PAINT EXISTING HANGAR WALLS PT-3

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.2 E.3

E.4 E.5

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

5.3

D4

B.1

B.2

B.3

B.4

C.1

C.9

E 6

E A

D3

4.7

ED.5

EDS

COMPUTER

125A

MULTI-PURPOSE

MULTI-PURPOSE

AIE PTT

TOOL ROOM

CPT

WPT

TELECOM

FIRE ROOM

MULTI-PURPOSE

MULTI-PURPOSE

STAIR 1

S01

STUDENT

WORK AREA

CORRIDOR

VESTIBULE

REGISTRARS

OFFICE

102A

REGISTRARS

ADMINISTRATION

ADMINISTRATION

105A

WELLNESS

105B

OFFICE

105C

OFFICE

105D

OFFICE

105E

WOMEN'S RR

MEN'S RR

BREAK

ROOM

JANITOR'S

CLASSROOM

CLASSROOM

EDS

IAST

ELECTRICAL

CORRIDOR

110B

CIRCULATION

OFT

OFT

OFT

COMPUTER

TRS

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

OVERALL

BA

B1455

23 NOV 2022

IN121

O V

E R

A L L S

IG

N

A G

E P

L A

N

L E

V E

L

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

1/16" = 1'-0"A1

OVERALL SIGNAGE PLAN - LEVEL 1

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

S1

SIGNAGE KEY

INDICATES SIGN MOUNTED ON WALL.

REFER TO SCHEDULE ON 1-611

E.1

E.A

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.2

B.1

B.2

B.3

B.4

C.1

C.9

M A

T C

H L

IN

E

A

IN

EDS

COMPUTER

125A

EDS

AIE PTT

MULTI-PURPOSE

MULTI-PURPOSE

TOOL ROOM

S29 S27 S26 S25

S24

S28

S30

S31

S38

IAST

CIRCULATION

OFT

OFT

OFT

COMPUTER

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA A

A

B1455

23 NOV 2022

IN122

P A

R T

IA

L S

IG

N

A G

E P

L A

N

L E

V E

L

A

R E

A A

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

GENERAL NOTES - SIGNAGE

A SIGNAGE LOCATION/PLACEMENT MUST MEET ABAAS

REQUIREMENTS.

B ALL SIGNAGE MUST COMPLY WITH UFC 3-120-01

STANDARDS.

C ROOM NUMBERS SHOWN ON PLANS ARE FOR

CONSTRUCTION PURPOSES, NOT NECESSARILY THE

USER'S PREFERRED NUMBERING SYSTEM.

COORDINATE ALL ROOM NUMBERS AND VERBIAGE

FOR SIGNS WITH CONTRACTING OFFICER PRIOR TO

FABRICATION.

D ENSURE THAT ALL SIGN INSERTS CAN BE EASILY

REMOVED/ REPLACED. CONSIDER INSTALLATION OF

SIGNS IN TIGHT CORNERS AND ALCOVES/ SIDELIGHTS

TO ENSURE THAT SIGN INSERT IS ACCESSIBLE.

E MOUNT ALL LIKE-SIGNS AT SAME HEIGHT.

F SIGNAGE IS INTENDED TO MATCH EXISTING. VERIFY

EXISTING SIGNAGE TYPE AND BACKGROUND COLOR

PRIOR TO ORDERING.

1/8" = 1'-0"A1

PARTIAL SIGNAGE PLAN - LEVEL 1 - AREA A

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

INDICATES SIGN MOUNTED ON WALL.

REFER TO SCHEDULE ON 1-611

E.A

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.3

E.4

E.5

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

B.1

B.2

B.3

B.4

C.1

C.9

2.6 E 62.52.1 2.2 2.3 2.4

D4

D3

4.7

M A

T C

H L

IN

E

A

IN

ELECTRICAL

CPT

ELEVATOR

E01

STAIR 1

S01

WPT

TELECOM

FIRE ROOM

MULTI-PURPOSE

CLASSROOM

CLASSROOM

MULTI-PURPOSE

STUDENT

WORK AREA

MEN'S RR

WOMEN'S RR

108 ADMINISTRATION

ADMINISTRATION

105A

WELLNESS

ROOM

105B

OFFICE

105C

OFFICE

105D

OFFICE

105E

BREAK

ROOM

JANITORS

REGISTRARS

CORRIDOR

REGISTRARS

OFFICE

102A

VESTIBULE

TRS

S4 S2

S3

S14 S13S15S16 S18S20

S17

S40

S21 S22 S23

S39

S8 S9 S10 S11

S19

S6 S5

S7

S12

S41

STORAGE

115A

S45

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA B

B

B1455

23 NOV 2022

IN123

P A

R T

IA

L S

IG

N

A G

E P

L A

N

L E

V E

L

A

R E

A B

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

GENERAL NOTES - SIGNAGE

A SIGNAGE LOCATION/PLACEMENT MUST MEET ABAAS

REQUIREMENTS.

B ALL SIGNAGE MUST COMPLY WITH UFC 3-120-01

STANDARDS.

C ROOM NUMBERS SHOWN ON PLANS ARE FOR

CONSTRUCTION PURPOSES, NOT NECESSARILY THE

USER'S PREFERRED NUMBERING SYSTEM.

COORDINATE ALL ROOM NUMBERS AND VERBIAGE

FOR SIGNS WITH CONTRACTING OFFICER PRIOR TO

FABRICATION.

D ENSURE THAT ALL SIGN INSERTS CAN BE EASILY

REMOVED/ REPLACED. CONSIDER INSTALLATION OF

SIGNS IN TIGHT CORNERS AND ALCOVES/ SIDELIGHTS

TO ENSURE THAT SIGN INSERT IS ACCESSIBLE.

E MOUNT ALL LIKE-SIGNS AT SAME HEIGHT.

F SIGNAGE IS INTENDED TO MATCH EXISTING. VERIFY

EXISTING SIGNAGE TYPE AND BACKGROUND COLOR

PRIOR TO ORDERING.

1/8" = 1'-0"A1

PARTIAL SIGNAGE PLAN - LEVEL 1 - AREA B

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.2 E.3

E.4

E.5

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

5.3

D4

B.1

B.2

B.3

B.4

C.1

C.9

E 6

E A

E.B

D4

D3

4.7

ED.5

MECH MEZZ

MISSION

PLANNNG

MISSION

PLANNING

CLASS

CORRIDOR

200A

STAIR 1

S01

TSC

COMM

CLOSET

CORRIDOR

200B

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

8 16 3241216

SCALE: 1/16"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

OVERALL

BA

B1455

23 NOV 2022

IN131

O V

E R

A L L S

IG

N

A G

E P

L A

N

L E

V E

L

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

1/16" = 1'-0"A1

OVERALL SIGNAGE PLAN - LEVEL 2

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

INDICATES SIGN MOUNTED ON WALL.

REFER TO SCHEDULE ON 1-611

E.A

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.3

E.4

E.5

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

B.1

B.2

B.3

B.4

C.1

C.9

2.6 E 6

2.52.1 2.2 2.3 2.4

D4

D3

4.7

MISSION

PLANNING

CLASS

STAIR 1

S01

TSC

COMM

CHASE

MISSION

PLANNNG

ELEVATOR

E01

CORRIDOR

200A

S34

S36

S32

S35

S37

S33

S42

S44

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA B

B

B1455

23 NOV 2022

IN132

P A

R T

IA

L S

IG

N

A G

E P

L A

N

L E

V E

L

A

R E

A B

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

GENERAL NOTES - SIGNAGE

A SIGNAGE LOCATION/PLACEMENT MUST MEET ABAAS

REQUIREMENTS.

B ALL SIGNAGE MUST COMPLY WITH UFC 3-120-01

STANDARDS.

C ROOM NUMBERS SHOWN ON PLANS ARE FOR

CONSTRUCTION PURPOSES, NOT NECESSARILY THE

USER'S PREFERRED NUMBERING SYSTEM.

COORDINATE ALL ROOM NUMBERS AND VERBIAGE

FOR SIGNS WITH CONTRACTING OFFICER PRIOR TO

FABRICATION.

D ENSURE THAT ALL SIGN INSERTS CAN BE EASILY

REMOVED/ REPLACED. CONSIDER INSTALLATION OF

SIGNS IN TIGHT CORNERS AND ALCOVES/ SIDELIGHTS

TO ENSURE THAT SIGN INSERT IS ACCESSIBLE.

E MOUNT ALL LIKE-SIGNS AT SAME HEIGHT.

F SIGNAGE IS INTENDED TO MATCH EXISTING. VERIFY

EXISTING SIGNAGE TYPE AND BACKGROUND COLOR

PRIOR TO ORDERING.

1/8" = 1'-0"A1

PARTIAL SIGNAGE PLAN - LEVEL 2 - AREA B

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

B1455

23 NOV 2022

I-601

F

IN

IS

H

M A

T E

R

IA

L L

E G

E N

D

D E

T A

IL

S

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

I-

FINISH LEGEND

ITEM

CODE DESCRIPTION MANUFACTURER MODEL COLOR SIZE NOTES

FLOORING

CPT-1 CARPET TILE MILLIKEN MAJOR FREQUENCY ONE -

DISTORTION

PERCEIVE DTN218-106 9.85" X 39.4" ASHLAR INSTALLATION

CPT-2 CARPET TILE MILLIKEN MAJOR FREQENCY ONE -

VIBRATION

PERCEIVE VBN218-106 9.85" X 39.4" ASHLAR INSTALLATION

EXC-1 EPOXY COATING TENNANT ECO-MPE MULTI PURPOSE

EPOXY

BATTLESHIP GRAY --- INSTALL WHERE NOTED

LVT-1 LUXURY VINYL TILE MILLIKEN FORTIFIED FOUNDATIONS 2.5MM CHARLOTTE CHT120 18" X 18" INSTALL WHERE NOTED

PFT-1 PORCELAIN FLOOR TILE STONEPEAK SIMPLY MODERN SIMPLY GREY 12" X 24" 1/3 OFFSET INSTALLATION.

RAF-1 RAISED ACCESS FLOORING COMX CONCRETE FILLED STEEL

ACCESS FLOOR SYSTEM

GRAY STARLINE

ST6001

24" X 24" OFT COMPUTER ROOM AND CORRIDOR RAMP/LANDING AS NOTED

RF-1 RUBBER TREADS AND RISERS TARKETT STAIRWELL MANAGEMENT BURNT UMBER 63 --- INTERIOR STAIRS, RISERS AND LANDING.

SC-1 SEALED CONCRETE SURECRETE COLORTEC 400WB DOVE GRAY 12 --- INSTALL WHERE NOTED

SDT-1 STATIC DISSIPATIVE TILE JOHNSONITE IQ GRANIT SD TILE SIDEWALK 0726 24" X 24" INSTALL WHERE NOTED

BASE

CB-1 METAL COVE TRANSITION SCHLUTER DILEX AHK SATIN ANODIZED

ALUMINUM AE

--- INSTALL IN RESTROOMS

RB-1 RESILIENT BASE TARKETT TRADITIONAL WALL BASE BURNT UMBER 63 4" H GENERAL USE (COVE AT RESILIENT FLOORING / STRAIGHT AT CARPET)

WALLS

AWP-1 ACOUSTICAL WALL PANEL CF STINSON NIKKO SHARK --- REFER TO I-203 FOR ELEVATION DETAILS

EW-1 ELEVATOR WALL TK ELEVATOR --- BRUSHED STAINLESS

STEEL

FRP-1 FIBER REINFORCED PANEL MARLITE SYMMETRIX FRP WHITE C 100-G44 --- JANITOR WALLS.

PT-1 PAINT BENJAMIN MOORE EGGSHELL FINISH NATURAL CREAM

OC-14

--- GENERAL USE UON

PT-2 PAINT BENJAMIN MOORE EGGSHELL FINISH (WALLS) /

SEMI-GLOSS FINISH (DOORS &

TRIM)

BRIARWOOD HC-175 --- ACCENT WALLS; SIGNAGE BACKGROUND

PT-3 PAINT BENJAMIN MOORE EGGSHELL FINISH ICE MIST OC-67 --- HANGAR WALL INTERIOR

PT-4 PAINT BENJAMIN MOORE SEMI-GLOSS FINISH JET BLACK 2120-10 --- DOORS & DOOR TRIM; STAIR ASSEMBLY

PWT-1 PORCELAIN WALL TILE STONEPEAK SIMPLY MODERN SIMPLY CREME 12" X 24" RESTROOM WALLS

PWT-2 PORCELAIN WALL TILE STONEPEAK SIMPLY MODERN SIMPLY GREY 2" X 2" MOSAIC ON A

12" SHEET

RESTROOM WALL ACCENT

CEILINGS

ACT-1 ACCOUSTICAL CEILING TILE ARMSTRONG CEILINGS OPTIMA TEGULAR WHITE TILE W/ WITH

BLIZZARD WHITE GRID

24" X 24" X 1", 15/16"

TEGULAR

INSTALL IN ALL AREAS U.O.N.

EC-1 ELEVATOR CEILING TK ELEVATOR ... BRUSHED STAINLESS

STEEL

GYP-1 GYPSUM BOARD CEILING BENJAMIN MOORE FLAT FINISH ICE MIST OC-67 --- PAINTED GYPSUM BOARD CEILINGS

OTS-1 OPEN TO STRUCTURE BENJAMIN MOORE FLAT FINISH ICE MIST OC-67 --- PAINTED EXPOSED CEILINGS INCLUDING MEP WHERE ALLOWED BY CODE

MISCELLANEOUS

CG-1 CORNER GUARD CS ACROVYN SSM-20AN SURFACE MOUNTED PEARL 934 2" LEGS INSTALL ON ALL OUTSIDE CORNERS

CL-1 CELL PHONE LOCKERS SALSBURY INDUSTRIES SERIES 19158-25 ALUMINUM 7 LOCKERS HIGH x 3

LOCKERS WIDE

REFER TO I-201 FOR DETAILS

FPF-1 FOLDING PARTITION FABRIC MODERNFOLD LINEAGE PEDIGREE --- MOVABLE PARTITION PANEL FINISH

GR-1 GROUT LATICRETE PERMACOLOR SELECT 34 SANDSTONE --- USED WITH PFT-1

GR-2 GROUT LATICRETE PERMACOLOR SELECT 89 SMOKE GREY --- USED WITH PWT-1 & PWT-2

PL-1 PLASTIC LAMINATE FORMICA --- SILVER RIFTWOOD

6413-NG

--- BREAKROOM CABINETS; ELEVATOR INTERIOR PANELS

SS-1 SOLID SURFACE WILSONART --- MORNING ICE 9204CE --- RESTROOM, BREAK ROOM COUNTERTOP AND BACKSPLASH

SS-2 SOLID SURFACE CORIAN --- CANVAS --- WINDOW SILLS

TP-1 TOILET PARTITIONS ASI GLOBAL PARTITIONS SOLID PHENOLIC CORE FOG 3450C --- RESTROOM TOILET PARTITIONS

WS-1 WINDOW SHADE MECHOSHADE ECOVEIL SCREEN - 5% OPEN EGGSHELL 1366 --- 5% OPENESS, MANUAL ROLLERSHADE. INSTALL AT ALL WINDOWS, U.N.O.

WST-1 WOOD STAIN, INTERIOR WOOD

DOORS

SHERWIN WILLIAMS MINWAX TINTABLE STAINS CLASSIC GRAY MW271 --- APPLY ON ALL WOOD DOORS.

GENERAL NOTES-FINISH LEGEND

A MANUFACTURERS AND COLORS LISTED ARE INTENDED TO

ESTABLISH LEVEL OF QUALITY, COLOR & FINISH, AND ARE NOT

INTENDED TO LIMIT THE SELECTION OF OTHER MANUFACTURERS

FOR EQUAL PRODUCTS. AFRC HQ INTERIOR DESIGNER MUST BE

COPIED ON ALL SUBSTITUTIONS FOR APPROVAL.

B ALL FINISHES ARE TO BE INSTALLED/ APPLIED IN ACCORDANCE

WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS.

C FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING FINISH

MATERIALS.

D ALL FLOORING TRANSITIONS ARE TO OCCUR AT THE CENTERLINE

OF THE DOOR, DOORWAY, OR CEILING UON.

E PAINTED GYPSUM BOARD WALLS MUST HAVE AN EGGSHELL FINISH

UON.

F PAINTED GYPSUM BOARD CEILINGS MUST HAVE A FLAT FINISH

UON.

G METAL DOORS AND FRAMES SCHEDULED TO BE PAINTED MUST

HAVE A SEMI GLOSS FINISH UON, PAINT PT-4. WOOD DOORS MUST

BE STAINED AS SPECIFIED

H REFER TO REFLECTED CEILING PLANS ON AE121 TO AE133 FOR

ADDITIONAL INFORMATION.

J REFER TO FINISH PLANS SHEETS IN101 TO IN112 AND ROOM FINISH

SCHEDULE I-602 FOR FINISHES BY ROOM.

K REFER TO A-201 FOR INFORMATION REGARDING EXTERIOR

FINISHES.

L INSTALL METAL COVE TRIM AT ALL TILE INSIDE CORNER AND

FLOOR TO WALL TRANSITIONS IN RESTROOMS 108 AND 109. REFER

TO F7/I-501 AND E7/I-501

M ALL OUTSIDE CORNERS ARE TO RECEIVE CORNER GUARDS TO

MATCH ADJACENT WALL FINISH, REFER TO C7/I-501

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

FINISH KEY LEGEND

CEILING FINISHES

ACT ACOUSTICAL CEILING TILE

EC-1 ELEVATOR CEILING

GYP PAINTED GYPSUM BOARD

OTS OPEN TO STRUCTURE

WALL FINISHES

AWP ACOUSTIC WALL PANELING

EW-1 ELEVATOR WALL

FRP-1 FIBER REINFORCED PLASTIC

PT PAINT

PWT PORCELAIN WALL TILE

BASE FINISHES

RB RESILIENT BASE

CB METAL COVE TRANSITION

FLOOR FINISHES

CPT CARPET TILE

EXC EPOXY

LVT LUXURY VINYL TILE

PFT PORCELAIN FLOOR TILE

SC SEALED CONCRETE

SDT STATIC DISSIPATIVE TILE

RF STAIR TREAD & RISERS

RAF RAISED ACCESS FLOORING

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

B1455

23 NOV 2022

I-602

R O

O M

F

IN

IS

H

S C

H E

D U

L E

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

I-

GENERAL NOTES-FINISH LEGEND

A MANUFACTURERS AND COLORS LISTED ARE INTENDED TO

ESTABLISH LEVEL OF QUALITY, COLOR & FINISH, AND ARE NOT

INTENDED TO LIMIT THE SELECTION OF OTHER MANUFACTURERS

FOR EQUAL PRODUCTS. AFRC HQ INTERIOR DESIGNER MUST BE

COPIED ON ALL SUBSTITUTIONS FOR APPROVAL.

B ALL FINISHES ARE TO BE INSTALLED/ APPLIED IN ACCORDANCE

WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS.

C FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING FINISH

MATERIALS.

D ALL FLOORING TRANSITIONS ARE TO OCCUR AT THE CENTERLINE

OF THE DOOR, DOORWAY, OR CEILING UON.

E PAINTED GYPSUM BOARD WALLS MUST HAVE AN EGGSHELL FINISH

UON.

F PAINTED GYPSUM BOARD CEILINGS MUST HAVE A FLAT FINISH

UON.

G METAL DOORS AND FRAMES SCHEDULED TO BE PAINTED MUST

HAVE A SEMI GLOSS FINISH UON, PAINT PT-4. WOOD DOORS MUST

BE STAINED AS SPECIFIED

H REFER TO REFLECTED CEILING PLANS ON AE121 TO AE133 FOR

ADDITIONAL INFORMATION.

J REFER TO FINISH PLANS SHEETS IN101 TO IN112 AND ROOM FINISH

SCHEDULE I-602 FOR FINISHES BY ROOM.

K REFER TO A-201 FOR INFORMATION REGARDING EXTERIOR

FINISHES.

L INSTALL METAL COVE TRIM AT ALL TILE INSIDE CORNER AND

FLOOR TO WALL TRANSITIONS IN RESTROOMS 108 AND 109. REFER

TO F7/I-501 AND E7/I-501

M ALL OUTSIDE CORNERS ARE TO RECEIVE CORNER GUARDS TO

MATCH ADJACENT WALL FINISH, REFER TO C7/I-501

ROOM FINISH SCHEDULE

ROOM NAME

FLOOR

FINISH

BASE

FINISH

WALL FINISH CEILING

FINISHNORTH EAST SOUTH WEST

100 VESTIBULE LVT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

101 CORRIDOR LVT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ETR/GYP-1

102 REGISTRARS CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

102A REGISTRARS

OFFICE

CPT-2 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1

103 STUDENT WORK

AREA

CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 ACT-1

104 TRS CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1

105 ADMINISTRATION CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

105A ADMINISTRATION CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

105B WELLNESS ROOM CPT-2 RB-1 PT-1 PT-1 PT-1 PT-2 ACT-1

105C OFFICE CPT-2 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

105D OFFICE CPT-2 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

105E OFFICE CPT-2 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

106 BREAK ROOM LVT-1 RB-1 PT-1 PT-1 PT-1 PT-1 / SS-1 ACT-1/GYP-1

107 JANITORS SC-1 RB-1 PT-1 / FRP-1 PT-1 / FRP-1 PT-1 / FRP-1 PT-1 / FRP-1 OTS-1

108 WOMEN'S RR PFT-1 CB-1 PWT-1,2 PWT-1,2 PWT-1,2 PWT-1,2 GYP-1

109 MEN'S RR PFT-1 CB-1 PWT-1,2 PWT-1,2 PWT-1,2 PWT-1,2 GYP-1

110 CIRCULATION EXC-1 RB-1 PT-1 PT-1 PT-1 PT-1 ...

110A CORRIDOR LVT-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

110B CORRIDOR LVT-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

111 CLASSROOM CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1/GYP-1

112 MULTI-PURPOSE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1/GYP-1

113 CLASSROOM CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1/GYP-1

114 MULTI-PURPOSE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1/GYP-1

115 IAST EXC-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

116 AIE PTT EXC-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

117 CPT CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

118 WPT CPT-1 RB-1 PT-1 / AWP-1 PT-1 / AWP-1 PT-1 / AWP-1 PT-1 / AWP-1 OTS-1

119 TELECOM SDT-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

120 OFT EXC-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

121 OFT EXC-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

122 TOOL ROOM SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

123 MULTI-PURPOSE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1/GYP-1

124 MULTI-PURPOSE CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1/GYP-1

125 EDS RAF-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

125A EDS COMPUTER RAF-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

126 OFT COMPUTER RAF-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

130 FIRE ROOM SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

140 ELECTRICAL SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

150 MECH MEZZ SC-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

200A CORRIDOR LVT-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

200B CORRIDOR LVT-1 / RAF -1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

201 TSC CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

202 CLASS CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 ACT-1

203 MISSION

PLANNNG

CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1

204 COMM CLOSET SDT-1 RB-1 PT-1 PT-1 PT-1 PT-1 OTS-1

205 MISSION

PLANNING

CPT-1 RB-1 PT-2 PT-1 PT-1 PT-1 ACT-1

E01 ELEVATOR CPT-1 ... EW-1 EW-1 EW-1 EW-1 EC-1

S01 STAIR 1 RF-1 RB-1 N/A N/A N/A N/A OTS-1

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.2 E.3

E.4 E.5

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

5.3

D4

B.1

B.2

B.3

B.4

C.1

C.9

E 6

E A

D3

4.7

ED.5

EDS

COMPUTER

125A

MULTI-PURPOSE

MULTI-PURPOSE

AIE PTT

TOOL ROOM

CPT

WPT

TELECOM

FIRE ROOM

MULTI-PURPOSE

MULTI-PURPOSE

STAIR 1

S01

STUDENT

WORK AREA

CORRIDOR

VESTIBULE

REGISTRARS

OFFICE

102A

REGISTRARS

ADMINISTRATION

ADMINISTRATION

105A

WELLNESS

105B

OFFICE

105C

OFFICE

105D

OFFICE

105E

WOMEN'S RR

MEN'S RR

BREAK

ROOM

JANITOR'S

CLASSROOM

CLASSROOM

EDS

IAST

ELECTRICAL

CORRIDOR

110B

CIRCULATION

OFT

OFT

OFT

COMPUTER

TRS

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

OVERALL

BA

B1455

23 NOV 2022

IN121

O V

E R

A L L S

IG

N

A G

E P

L A

N

L E

V E

L

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

1/16" = 1'-0"A1

OVERALL SIGNAGE PLAN - LEVEL 1

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

INDICATES SIGN MOUNTED ON WALL.

REFER TO SCHEDULE ON 1-611

E.1

E.A

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.2

B.1

B.2

B.3

B.4

C.1

C.9

M A

T C

H L

IN

E

A

IN

EDS

COMPUTER

125A

EDS

AIE PTT

MULTI-PURPOSE

MULTI-PURPOSE

TOOL ROOM

S29 S27 S26 S25

S24

S28

S30

S31

S38

IAST

CIRCULATION

OFT

OFT

OFT

COMPUTER

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA A

A

B1455

23 NOV 2022

IN122

P A

R T

IA

L S

IG

N

A G

E P

L A

N

L E

V E

L

A

R E

A A

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

GENERAL NOTES - SIGNAGE

A SIGNAGE LOCATION/PLACEMENT MUST MEET ABAAS

REQUIREMENTS.

B ALL SIGNAGE MUST COMPLY WITH UFC 3-120-01

STANDARDS.

C ROOM NUMBERS SHOWN ON PLANS ARE FOR

CONSTRUCTION PURPOSES, NOT NECESSARILY THE

USER'S PREFERRED NUMBERING SYSTEM.

COORDINATE ALL ROOM NUMBERS AND VERBIAGE

FOR SIGNS WITH CONTRACTING OFFICER PRIOR TO

FABRICATION.

D ENSURE THAT ALL SIGN INSERTS CAN BE EASILY

REMOVED/ REPLACED. CONSIDER INSTALLATION OF

SIGNS IN TIGHT CORNERS AND ALCOVES/ SIDELIGHTS

TO ENSURE THAT SIGN INSERT IS ACCESSIBLE.

E MOUNT ALL LIKE-SIGNS AT SAME HEIGHT.

F SIGNAGE IS INTENDED TO MATCH EXISTING. VERIFY

EXISTING SIGNAGE TYPE AND BACKGROUND COLOR

PRIOR TO ORDERING.

1/8" = 1'-0"A1

PARTIAL SIGNAGE PLAN - LEVEL 1 - AREA A

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

INDICATES SIGN MOUNTED ON WALL.

REFER TO SCHEDULE ON 1-611

E.A

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.3

E.4

E.5

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

B.1

B.2

B.3

B.4

C.1

C.9

2.6 E 62.52.1 2.2 2.3 2.4

D4

D3

4.7

M A

T C

H L

IN

E

A

IN

ELECTRICAL

CPT

ELEVATOR

E01

STAIR 1

S01

WPT

TELECOM

FIRE ROOM

MULTI-PURPOSE

CLASSROOM

CLASSROOM

MULTI-PURPOSE

STUDENT

WORK AREA

MEN'S RR

WOMEN'S RR

108 ADMINISTRATION

ADMINISTRATION

105A

WELLNESS

ROOM

105B

OFFICE

105C

OFFICE

105D

OFFICE

105E

BREAK

ROOM

JANITORS

REGISTRARS

CORRIDOR

REGISTRARS

OFFICE

102A

VESTIBULE

TRS

S4 S2

S3

S14 S13S15S16 S18S20

S17

S40

S21 S22 S23

S39

S8 S9 S10 S11

S19

S6 S5

S7

S12

S41

STORAGE

115A

S45

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA B

B

B1455

23 NOV 2022

IN123

P A

R T

IA

L S

IG

N

A G

E P

L A

N

L E

V E

L

A

R E

A B

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

GENERAL NOTES - SIGNAGE

A SIGNAGE LOCATION/PLACEMENT MUST MEET ABAAS

REQUIREMENTS.

B ALL SIGNAGE MUST COMPLY WITH UFC 3-120-01

STANDARDS.

C ROOM NUMBERS SHOWN ON PLANS ARE FOR

CONSTRUCTION PURPOSES, NOT NECESSARILY THE

USER'S PREFERRED NUMBERING SYSTEM.

COORDINATE ALL ROOM NUMBERS AND VERBIAGE

FOR SIGNS WITH CONTRACTING OFFICER PRIOR TO

FABRICATION.

D ENSURE THAT ALL SIGN INSERTS CAN BE EASILY

REMOVED/ REPLACED. CONSIDER INSTALLATION OF

SIGNS IN TIGHT CORNERS AND ALCOVES/ SIDELIGHTS

TO ENSURE THAT SIGN INSERT IS ACCESSIBLE.

E MOUNT ALL LIKE-SIGNS AT SAME HEIGHT.

F SIGNAGE IS INTENDED TO MATCH EXISTING. VERIFY

EXISTING SIGNAGE TYPE AND BACKGROUND COLOR

PRIOR TO ORDERING.

1/8" = 1'-0"A1

PARTIAL SIGNAGE PLAN - LEVEL 1 - AREA B

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.2 E.3

E.4

E.5

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

5.3

D4

B.1

B.2

B.3

B.4

C.1

C.9

E 6

E A

E.B

D4

D3

4.7

ED.5

MECH MEZZ

MISSION

PLANNNG

MISSION

PLANNING

CLASS

CORRIDOR

200A

STAIR 1

S01

TSC

COMM

CLOSET

CORRIDOR

200B

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

8 16 3241216

SCALE: 1/16"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

OVERALL

BA

B1455

23 NOV 2022

IN131

O V

E R

A L L S

IG

N

A G

E P

L A

N

L E

V E

L

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

1/16" = 1'-0"A1

OVERALL SIGNAGE PLAN - LEVEL 2

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

INDICATES SIGN MOUNTED ON WALL.

REFER TO SCHEDULE ON 1-611

E.A

E.A.8

E.B.5

E.C.4

E.D.2

E.D.4

E.D.5

E.D.1

E.3

E.4

E.5

E.C

E.D

E.E

E.F

E.G

E.F.1

E.F.9

B.1

B.2

B.3

B.4

C.1

C.9

2.6 E 6

2.52.1 2.2 2.3 2.4

D4

D3

4.7

MISSION

PLANNING

CLASS

STAIR 1

S01

TSC

COMM

CHASE

MISSION

PLANNNG

ELEVATOR

E01

CORRIDOR

200A

S34

S36

S32

S35

S37

S33

S42

S44

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TRUE N

PLAN

NORTH

TRUE N

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

KEY PLAN

AREA B

B

B1455

23 NOV 2022

IN132

P A

R T

IA

L S

IG

N

A G

E P

L A

N

L E

V E

L

A

R E

A B

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

IN

GENERAL NOTES - SIGNAGE

A SIGNAGE LOCATION/PLACEMENT MUST MEET ABAAS

REQUIREMENTS.

B ALL SIGNAGE MUST COMPLY WITH UFC 3-120-01

STANDARDS.

C ROOM NUMBERS SHOWN ON PLANS ARE FOR

CONSTRUCTION PURPOSES, NOT NECESSARILY THE

USER'S PREFERRED NUMBERING SYSTEM.

COORDINATE ALL ROOM NUMBERS AND VERBIAGE

FOR SIGNS WITH CONTRACTING OFFICER PRIOR TO

FABRICATION.

D ENSURE THAT ALL SIGN INSERTS CAN BE EASILY

REMOVED/ REPLACED. CONSIDER INSTALLATION OF

SIGNS IN TIGHT CORNERS AND ALCOVES/ SIDELIGHTS

TO ENSURE THAT SIGN INSERT IS ACCESSIBLE.

E MOUNT ALL LIKE-SIGNS AT SAME HEIGHT.

F SIGNAGE IS INTENDED TO MATCH EXISTING. VERIFY

EXISTING SIGNAGE TYPE AND BACKGROUND COLOR

PRIOR TO ORDERING.

1/8" = 1'-0"A1

PARTIAL SIGNAGE PLAN - LEVEL 2 - AREA B

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

IN CASE OF FIRE,

DO NOT USE ELEVATOR.

USE EXIT STAIRS UNLESS

OTHERWISE INSTRUCTED.

/8

1' - 0"

11 1/2"1/4" 1/4"

TEXT:

INSERT:

HELVETICA NEUE 55 ROMAN, 5/8"

CAPITAL LETTER HEIGHT, CENTERED

REPLACABLE EVACUATION MAP

EVACUATION MAP

9"

HELVETICA NEUE 55 ROMAN, 1-1/2" CAPITAL LETTER HEIGHT,

FLUSH LEFT, TACTILE ROOM NUMBER ACCOMPANIED BY

GRADE TWO BRAILLE

HELVETICA NEUE 55 ROMAN, 3/4" CAPITAL LETTER HEIGHT,

FLUSH LEFT. TACTILE ROOM NAME WITH GRADE TWO

BRAILLE.

SIGN SHALL HAVE WHITE LETTERS ON COLORED

BACKGROUND.

FIRE TRAINING

CLASSROOM

8 1/2"

/2

/4

1/4" 1/4"

ROOM NUMBER:

ROOM NAME:

S Y

M B

O L

WOMEN 1

HELVETICA NEUE 55 ROMAN, 1-1/2" TACTILE ROOM

NUMBER WITH GRADE TWO BRAILLE.

UPPER CASE HELVETICA NEUE 55 ROMAN, 1"

CAPITAL LETTER HEIGHT, FLUSH LEFT,

ACCOMPANIED BY GRADE TWO BRAILLE.

ROOM NAME TO BE WHITE TEXT ON A COLORED

BACKGROUND AND SYMBOLS TO BE COLORED ON A

WHITE BACKGROUND.

ROOM NUMBER:

ROOM NAME:

BB7BBB7A

1/4" 8 1/2" 1/4"

9"

E Q

E Q

MEN 1

1/4" 8 1/2" 1/4"

9"

E Q

E Q

S Y

M B

O L

9"

HELVETICA NEUE 55 ROMAN, 1 1/2" CAPITAL LETTER HEIGHT,

FLUSH LEFT, TACTILE ROOM NUMBER ACCOMPANIED BY

GRADE TWO BRAILLE

PRINTED PAPER INSERT WITH ROOM DESCRIPTION. UPPER

AND LOWER CASE HELVETICA NEUE 55 ROMAN, 3/4" CAPITAL

LETTER HEIGHT, FLUSH LEFT.

Classified Section

8 1/2"

/2

/4

1/4" 1/4"

ROOM NUMBER:

ROOM NAME:

STAIR A

EXIT 1

9"

8 1/2"1/4" 1/4"

/2

UPPER CASE HELVETICA NEUE 55 ROMAN,

1-1/2" CAPITAL LETTER HEIGHT, CENTERED,

ACCOMPANIED BY GRADE TWO BRAILLE.

UPPER CASE HELVETICA NEUE 55 ROMAN,

1" CAPITAL LETTER HEIGHT, CENTERED,

ACCOMPANIED BY GRADE TWO BRAILLE.

STAIR

DESIGNATION:

TEXT:

S Y

M B

O L

STAIR & FLOOR

NUMBER: HELVETICA MEDIUM, 38 (1 1/2") CAPITAL

LETTER HEIGHT, FLUSH LEFT.

ACCOMPANIED BY GRADE TWO BRAILLE.

BODY TEXT: UPPER AND LOWER CASE HELVETICA

MEDIUM, 12 (1/2") CAPITAL LETTER HEIGHT,

FLUSH LEFT.

WHITE LETTERS ON COLORED BACKGROUND.

SIGN VERBIAGE TO INDICATE FLOOR AND ROOF ACCESS PER PLAN.

STAIRWELL A

1' - 2"

NO ROOF ACCESS

LEVEL

EXIT AT LEVEL 1

STAIRWELL LETTER

ROOF ACCESS

CURRENT LEVEL TACTILE

CURRENT LEVEL TACTILE

EMERGENCY EXIT

NUMBER OF FLOORS

BRAILLE

FLOOR 2 OF 2

SIGNAGE AS

SCHEDULED

EQ EQ

M A

X

MOUNTING HEIGHT RANGE FOR TACTILE CHARACTERS.

DOOR MOUNTED SIGNS TO BE CENTERED ON DOOR WHERE APPLICABLE.

ALL SIMILAR SIGN TYPES TO BE MOUNTED UNIFORMLY THROUGHOUT BUILDING.

CL

TEXT

TEXT

M

IN

3"

STANDARD DOOR

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

6"6"

SCALE: 3"=1'-0"

04 2

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

GRAPHIC SCALE

B1455

23 NOV 2022

I-512

S

IG

N A

G E

D E

T A

IL

S

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

I-

3" = 1'-0"D3

ELEVATOR EGRESS SIGN DD2

3" = 1'-0"A1

PERMANENT ROOM IDENTIFICATION SIGN BB2A

3" = 1'-0"A7

RESTROOM IDENTIFICATION SIGN BB7

3" = 1'-0"A5

ROOM IDENTIFICATION SIGN BB2B

3" = 1'-0"D8

STAIR IDENTIFICATION SIGN SS1A

3" = 1'-0"D6

STAIRWELL SIGN BB4

GENERAL NOTES - SIGNAGE

A SIGNAGE LOCATION/PLACEMENT MUST MEET ABAAS

REQUIREMENTS.

B ALL SIGNAGE MUST COMPLY WITH UFC 3-120-01

STANDARDS.

C ROOM NUMBERS SHOWN ON PLANS ARE FOR

CONSTRUCTION PURPOSES, NOT NECESSARILY THE

USER'S PREFERRED NUMBERING SYSTEM.

COORDINATE ALL ROOM NUMBERS AND VERBIAGE

FOR SIGNS WITH CONTRACTING OFFICER PRIOR TO

FABRICATION.

D ENSURE THAT ALL SIGN INSERTS CAN BE EASILY

REMOVED/ REPLACED. CONSIDER INSTALLATION OF

SIGNS IN TIGHT CORNERS AND ALCOVES/ SIDELIGHTS

TO ENSURE THAT SIGN INSERT IS ACCESSIBLE.

E MOUNT ALL LIKE-SIGNS AT SAME HEIGHT.

F SIGNAGE IS INTENDED TO MATCH EXISTING. VERIFY

EXISTING SIGNAGE TYPE AND BACKGROUND COLOR

PRIOR TO ORDERING.

1/2" = 1'-0"D1

TYP SIGNAGE MOUNTING DIAGRAM

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

23 NOV 2022

T

E

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

TEXAS REGISTERED

ENGINEERING FIRM F-2966

NI

SED

R

OI

GI

S

TA

TE OF TEXA

S

10047

MACHELL LARAE ABOVE

R

N R

EGE

R

I ES T RE

D

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

R E

P A

IR

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

B F

O R

M H

-1

M A

X W

E L L A

IR

F

O R

C E

B A

S E

A

L A

B A

M A

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

N

O V

E O

L N

E S

S F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

X W

E L L

A

IR

F O

R C

E B

A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

F Z

TEXAS REGISTERED

ENGINEERING FIRM F-2966

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

P

N Q

S B

P

B1455

23 NOV 2022

I-611

S

IG

N A

G E

S C

H E

D U

L E

M A

B O

V E

H W

IL

S

O N

S L E

B E

A U

S X

H T

I-

SIGNAGE SCHEDULE

SIGN ROOM NAME

ROOM

NUMBER VERBIAGE SIGN TYPE DETAIL NO.

S2 REGISTRARS 102 REGISTRAR BB2B A5/I-512

S3 REGISTRARS OFFICE 102A REGISTRARS OFFICE BB2B A5/I-512

S4 STUDENT WORK AREA 103 STUDENT WORK AREA BB2B A5/I-512

S5 TRS 104 TRS BB2B A1/I-512

S6 ADMINISTRATION 105 ADMINISTRATION BB2B A5/I-512

S7 ADMINISTRATION 105A ADMINISTRATION BB2B A5/I-512

S8 WELLNESS ROOM 105B WELLNESS ROOM BB2B A5/I-512

S9 OFFICE 105C OFFICE BB2B A5/I-512

S10 OFFICE 105D OFFICE BB2B A5/I-512

S11 OFFICE 105E OFFICE BB2B A5/I-512

S12 BREAK ROOM BB2A A1/I-512

S13 BREAK ROOM 106 BREAK ROOM BB2A A1/I-512

S14 JANITORS 107 JANITORS BB2A A1/I-512

S15 WOMEN'S RR 108 WOMEN''S RESTROOM BB7A A7/I-512

S16 MEN'S RR 109 MEN'S RESTROOM BB7B A7/I-512

S17 CLASSROOM 111 CLASSROOM BB2B A5/I-512

S18 MULTI-PURPOSE 112 MULTI-PURPOSE BB2B A5/I-512

S19 CLASSROOM 113 CLASSROOM BB2B A5/I-512

S20 MULTI-PURPOSE 114 MULTI-PURPOSE BB2B A5/I-512

S21 CPT 117 CPT BB2A A1/I-512

S22 WPT 118 WPT BB2A A1/I-512

S23 TELECOM 119 TELECOM BB2A A1/I-512

S24 OFT 121 OFT COMPUTER BB2A A1/I-512

S25 TOOL ROOM 122 TOOL ROOM BB2A A1/I-512

S26 MULTI-PURPOSE 123 MULTI-PURPOSE BB2B A5/I-512

S27 MULTI-PURPOSE 124 MULTI-PURPOSE BB2B A5/I-512

S28 OFT COMPUTER 126 OFT COMPUTER BB2A A1/I-512

S29 EDS 125 EDS BB2A A1/I-512

S30 OFT 120 OFT BB2A A1/I-512

S31 OFT COMPUTER 126 OFT BB2A A1/I-512

S32 CLASS 202 CLASSROOM BB2B A5/I-512

S33 MISSION…