W912QR22R0010_Plans-0003.pdf
PDF 1 MB Posted
- Solicitation number
- W912QR22R0010
About this file
This document package includes furniture, fixture and equipment (FF&E) plans and mechanical schedules for the proposed Flight Simulator Facility at Patrick Space Force Base in Florida.
The FF&E plans outline the layout and specifications for workstations, seating, storage units, tables, and other furnishings for various areas on the first level. Mechanical schedules provide details for terminal units, exhaust fans, sound attenuators, and other HVAC components. Relevant technical information includes airflow rates, pressure drops, dimensions, voltages, and basis of design manufacturers.
The related federal contract opportunity is a solicitation for design/bid/build construction services for the Flight Simulator Facility with an estimated cost between $10-25 million. The NAICS code is 236220 and size determination is $39.5 million. The solicitation is full and open with HUBZone price evaluation. No contract award will be made until funds are appropriated. Offerors must register in SAM and submit through Bidder Inquiry in ProjNet.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
9 10 12 13
A
C
E
F
G
H
B
11 14 15 16 17 18
B.5
D
SECURITY
BREAK
WOMEN RR
103MEN RR
JANITOR
ADMIN
WELLNESS
ELEC
VESTIBULE
C100
LOBBY
C101
VTRAT
TELECOM
HH-60W IMAGE
GENERATION
115A
HC-130J IMAGE
GENERATION
109A
CORRIDOR
C102
HC-130J
SIMULATOR BAY
MECHANICAL
MECHANICAL
EQUIPMENT
YARD
MISSION
PLANNING
TSG
M A
T C
H L
IN
E
A
IF
CH4
(2)
D2
CH3
(4)
T4
CL1 CL1
CL1
CL1
ST1
CH1A
CL1
CH1A
EQ8
EQ7
EQ2
EQ3
CH1
(10)
T1
T2 (4)
D1
ST1
EQ3
CH1
(8)
CL1 CL1
3' - 8"101
EQ4
EQ5
ST2
(2)
T3
T2
CH1
(4)
17.4
M A
T C
H L
IN
E
A
IF
EQ1
TR4
TR3
CH4
(2)
CH1A
CL1
CH1
T2 CL1
P2 P1B
P3BP3A
P4
P5
CH1
(15)
WS2
(15)
P1A
WS1
(8)
EQ9
OFFICE
D2
CH2
(2)
T5
T R
U E
N
PLAN
NORTH
T R
U E
N
164 8268
SCALE: 1/8"=1'-0"
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
US Army Corps of Engineers
F Y
P
E R
S O
N N
E L
R E
C O
V E
R Y
F L
IG
H
T S
IM
U
L A
T O
R
P A
T R
IC
K
S P
A C
E F
O R
C E
B A
S E
F
L O
R
ID
A
Louisville District ®
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
PRELIMINARY FOR
REVIEW ONLY
THESE DOCUMENTS ARE
PRELIMINARY AND MAY NOT BE USED
FOR REGULATORY APPROVAL,
PERMIT OR CONSTRUCTION. THEY
WERE PREPARED BY, OR UNDER
SUPERVISION OF:
NAME
REGISTRATION # DATE
26 AUGUST 2021
JERI L. CHAMPINE
TX629
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
D R
A W
IN
G
C O
D E
T B
D
S
E P
T E
M B
E R
E O
L N
E S
S F
IL
E
N A
M E
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
P
T R
IC
K
S P
A C
E F
O R
C E
B A
S E
J
C O
B S
E N
G
IN
E E
R
IN
G G
R O
U P
I N
C
M a in
S tr e e t, F o rt
W o rt h
T X
J A
C O
B S
N o
D
TEXAS REGISTERED
ENGINEERING FIRM F-2966
CERTIFIED FINAL SUBMITTAL
P R
O J E
C T
N U
M B
E R
S
X H
T P
GRAPHIC SCALE
KEY PLAN
AREA B
B
TEXAS REGISTERED
ENGINEERING FIRM F-2966
IF103
F U
R N
IT
U
R E
F
IX
T
U R
E A
N D
E Q
U
IP
M E
N T
P L A
N
L E
V E
L
A
R E
A B
G .M
O L L
IC
A
G .M
O L L
IC
A
H .M
C E
L R
O Y
S X
H T
IF
GENERAL NOTES - FF&E PLANS
A FURNITURE, FIXTURE & EQUIPMENT (FF&E) IS SHOWN
FOR COORDINATION, AND IS CONTRACTOR FURNISHED
CONTRACTOR INSTALLED (CFCI).
B VERIFY FIELD CONDITIONS PRIOR TO ORDERING FF&E
TO ENSURE PROPER FIT OF ALL ITEMS.
C GENERAL CONTRACTOR TO COORDINATE WITH
FURNITURE DEALER TO ALLOW BUILDING ACCESS FOR
FIELD CONDITION VERIFICATION.
D GENERAL CONTRACTOR IS RESPONSIBLE FOR
ELECTRICAL CONNECTIONS TO THE BUILDING,
INCLUDING J BOXES TO SUPPORT FF&E. FURNITURE
DEALER IS RESPONSIBLE FOR THE ELECTRICAL
HOOKUP OF ALL FF&E, INCLUDING WHIPS FROM WALL
CONNECTIONS TO THE FURNITURE AND CONNECTING
PRE-WIRED PANELS, UP TO AND INCLUDING
FACEPLATES.
E INFORMATION TECHNOLOGY (IT) (PHONE/ LAN ETC.)
WIRING TO BE PROVIDED BY OTHERS AFTER
INSTALLATION: COORDINATE WITH CONTRACTING
OFFICER.
F PROVIDE ALL FF&E COMPONENTS REQUIRED TO
FULFILL THE DESIGN INTENT OUTLINED IN THE FF&E
PACKAGE, AND ASSEMBLE FF&E PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.FF&E
PROVIDER MUST COORDINATE WITH CONTRACTING
OFFICER AS REQUIRED TO ENSURE THAT ALL FF&E IS
SUCCESSFULLY INSTALLED AND OPERATIONAL PRIOR
TO OCCUPANCY.
G AWARDED FURNITURE DEALER TO PROVIDE SHOP
DRAWINGS WITH PANELS AND ELECTRICAL/COMM
CONNECTIONS FOR GOVERNMENT APPROVAL.
KEYNOTES
101 ADD WALL BLOCKING FOR MARKER BOARD/ MONITOR
AS REQUIRED.
FF&E - CFCI
MARK DESCRIPTION
WS1 WORKSTATION,
L-SHAPED 6'-0" x 6'-0"
WS2 WORKSTATION,
L-SHAPED 6'-0" x 5'-6"
FF&E - CFCI
MARK DESCRIPTION
CH1 CHAIR, TASK
CH1A CHAIR, TASK
CH2 CHAIR, TABLET ARM
CH3 CHAIR, BREAKROOM
CH4 CHAIR, GUEST
CL1 WALL CLOCK
D1 FACILITATOR'S STAND
D2 DESK U-SHAPED
MK-1 MARKERBOARD, 96" x 48"
P1A SYSTEMS FURNITURE
P1B SYSTEMS FURNITURE
P2 SYSTEMS FURNITURE
P3A SYSTEMS FURNITURE
P3B SYSTEMS FURNITURE
P4 SYSTEMS FURNITURE
P5 SYSTEMS FURNITURE
ST1 STORAGE, TWO DOOR
ST2 STORAGE, LAT FILE 2H
ST3 PALLET RACK, 96' x 48"
T1 TABLE, CONFERENCE
12'-0"
T2 TABLE, TRAINING 4'-0"
T3 TABLE, TRAINING 5'-0"
T4 TABLE, 30" ROUND
T5 TABLE, 30" SQUARE
T6 TABLE, CONFERENCE
6'-0"
TR3 TRASH RECEPTACLE
TR4 RECYCLING
RECEPTACLE
EQUIP GFGI - NIC
MARK DESCRIPTION
EQ1 85" MONITOR W/
BRACKET
EQ2 REFRIGERATOR,
COUNTER HEIGHT
EQ3 COPIER
EQ4 PRINTER, DESKTOP
SMALL
EQ5 PRINTER, DESKTOP
LARGE
EQ7 COFFEE MAKER
EQ8 REFRIGERATOR
EQ9 MICROWAVE
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
/2
W
2Q R
R
_P la ns -0
: ARIMS: 200A Disposition: Maintain for 15yrs after construction
THE RECORD
COPY OF THIS DRAWING
IS ON FILE AT THE OFFICES
IS RELEASED FOR THE PURPOSES OF
MANAGEMENT UNDER THE AUTHORITY OF
COORDINATION, AND/OR FACILITY
ARCHITECT/ENGINEER OF RECORD
76102. THIS ELECTRONIC DOCUMENT
NOT BE MODIFIED BY ANY PERSON
IT IS RELEASED.
UNDER WHOSE AUTHORITY
OTHER THAN THE PROFESSIONAL
THIS ELECTRONIC DOCUMENT MAY
OF JACOBS ENGINEERING GROUP
INC. 777 MAIN ST., FORT WORTH TX,
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
US Army Corps of Engineers
F Y
P
E R
S O
N N
E L
R E
C O
V E
R Y
F L
IG
H
T S
IM
U
L A
T O
R
P A
T R
IC
K
S P
A C
E F
O R
C E
B A
S E
F
L O
R
ID
A
Louisville District ®
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
D R
A W
IN
G
C O
D E
T B
D
S
E P
T E
M B
E R
E O
L N
E S
S F
IL
E
N A
M E
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
P
T R
IC
K
S P
A C
E F
O R
C E
B A
S E
J
C O
B S
E N
G
IN
E E
R
IN
G G
R O
U P
I N
C
M a in
S tr e e t, F o rt
W o rt h
T X
J A
C O
B S
N o
D
CERTIFIED FINAL SUBMITTAL
P R
O J E
C T
N U
M B
E R
S
X H
T P
TEXAS REGISTERED
ENGINEERING FIRM F-2966
M-603
M E
C H
A N
IC
A
L S
C H
E D
U L E
S
A F
O R
A N
A C
L E
A R
Q H
U A
N G
S X
H T
M
-6
3. 24V POWER TO BE PROVIDED BY CONTROLS CONTRACTOR. 120V CIRCUITS PROVIDED BY ELECTRICAL (RE: ELECTRICAL). CONTROLS CONTRACTOR TO PROVIDE 24V TRANSFORMER.
2. PROVIDE VAV-5 WITH ATTENUATOR OUTLET. ATTENUATOR ADDS 24" TO THE BASE UNIT LENGTH SHOWN ABOVE.
1. BASIS OF DESIGN KREUGER MODEL LMHS-HWC.
NOTES:
VAV-13 C101 LOBBY, 104 MENS RR, 106 OFFICE 05 180 65 90 0.3 3.4 55 90.0 140 128.8 0.6 1 12 0.22 24 15.5 12.0 8.0 39
VAV-12 124 AVDTT 06 380 100 190 0.3 5.1 55 79.9 140 128.0 0.9 1 12 0.35 24 15.5 12.0 8.0 39
VAV-11
C102 CORRIDOR (WEST), 122 LOAD MASTER, 123
WOMENS RR, 125 MENS RR
09 640 205 320 0.3 9.3 55 81.7 140 128.3 1.6 1 12 0.28 24 15.5 14.0 12.5 55
VAV-10 120 BRIEFING 05 310 65 155 0.3 4.6 55 82.3 140 127.8 0.8 1 12 0.28 24 15.5 12.0 8.0 39
VAV-9 118 BRIEFING 05 300 65 150 0.3 4.1 55 80.3 140 124.2 0.5 1 12 0.19 24 15.5 12.0 8.0 39
VAV-8 116 BRIEFING 05 340 70 170 0.3 4.4 55 78.9 140 124.1 0.6 1 12 0.21 24 15.5 12.0 8.0 39
VAV-7 114 BRIEFING 05 290 65 145 0.3 4.2 55 81.8 140 125.7 0.6 1 12 0.22 24 15.5 12.0 8.0 39
VAV-6 112 TSG 07 480 125 240 0.3 8.8 55 88.7 140 118.7 0.8 2 10 0.19 24 15.5 12.0 10.0 44
VAV-5 C102 CORRIDOR (EAST), 111 VTRAT 05 260 80 130 0.3 4.6 55 87.7 140 134.1 1.6 1 12 1.07 24 15.5 12.0 8.0 39
VAV-4 110 MISSION PLANNING 07 480 125 240 0.3 6.5 55 79.9 140 124.3 0.8 1 12 0.42 24 15.5 12.0 10.0 44
VAV-3 108 ADMIN 09 780 230 390 0.3 13.5 55 86.9 140 118.1 1.3 2 10 0.19 24 15.5 14.0 12.5 55
VAV-2 C100 VESTIBULE, 107 WELLNESS 04 130 40 65 0.3 2.5 55 90.0 140 130.4 0.5 1 10 0.18 24 15.5 12.0 8.0 39
VAV-1 101 SECURITY, 102 BREAK, 103 WOMENS RR 06 410 120 205 0.3 7.2 55 87.5 140 122.4 0.8 2 10 0.14 24 15.5 12.0 8.0 39
CAPACITY
(MBH)
EAT
(DB°F)
LAT
(DB°F)
EWT
(°F)
LWT
(°F)
FLOW
(GPM) ROWS FPI
COIL PD
(FT W.C.)
LENGTH
(NOTE 2) WIDTH HEIGHTMARK SERVES UNIT SIZE
DESIGN COOLING
AIRFLOW (CFM)
MINIMUM DAMPER
SETTING (CFM)
MAX. HEATING
AIRFLOW
(CFM)
MAX.
PRESSURE
DROP (IN W.C.)
HOT WATER COIL
ACTUATOR
VOLTAGE
MAX. UNIT DIMENSIONS (IN)
WEIGHT (LBS)
TERMINAL UNIT SCHEDULE
3. EF-5 MUST BE PROVIDED WITH 2-SPEED MOTOR, ECM, OR VFD (RE: E1/M-810 FOR SEQUENCE OF OPERATIONS).
VERTICAL DIRECTION IN ACCORDANCE WITH UFC 4-010-01.
2. ALL SUSPENDED EQUIPMENT GREATER THAN 31 LBS SHALL BE SUPPORTED WITH BRACING DESIGNED TO SUPPORT A MINIMUM OF 0.5X THE EQUIPMENT WEIGHT IN THE HORIZONTAL DIRECTION, AND 1.5X THE EQUIPMENT WEIGHT IN THE
1. PROVIDE EF-3, EF-4, & EF-5 WITH COUNTER-WEIGHTED BACKDRAFT DAMPERS.
NOTES:
EF-5 127 MECH ROOM 127 MECH ROOM (REFRIGERANT PURGE) INLINE, CENTRIFUGAL 985 0.3 DIRECT 1/4 120 1 60 45 GREENHECK SQ-100-VG
EF-4 109A HC-130J IMAGE GENERATION 115A HH-60W IMAGE GENERATION (CLEAN AGENT PURGE) INLINE, CENTRIFUGAL 1,050 0.5 DIRECT 1/4 120 1 60 45 GREENHECK SQ-100-VG
EF-3 109A HC-130J IMAGE GENERATION 109A HC-130J IMAGE GENERATION (CLEAN AGENT PURGE) INLINE, CENTRIFUGAL 1,250 0.5 DIRECT 1/2 120 1 60 55 GREENHECK SQ-120-VG
EF-2 123 WOMENS RR 123 WOMENS RR, 125 MENS RR INLINE, CENTRIFUGAL 300 0.5 DIRECT 1/10 120 1 60 49 GREENHECK SQ-90-VG
EF-1 127 MECH ROOM 103 WOMENS RR, 104 MENS RR, 105 JANITOR INLINE, CENTRIFUGAL 335 0.5 DIRECT 1/10 120 1 60 49 GREENHECK SQ-90-VG
DRIVE
TYPE HP (W)
VOLTAGE
(V) PHASE
FREQUENCY
(HZ)MARK LOCATION SERVES UNIT TYPE
AIRFLOW
(CFM)
E.S.P.
(IN
W.C.)
ELECTRICAL DATA MAX. UNIT
WEIGHT
(LBS) BASIS OF DESIGN
EXHAUST FAN SCHEDULE
ALL OTHER OCCUPIED SPACES: NC 30
SIMULATOR BAYS: NC 35
TO THE SOUND LEVELS INDICATED BELOW:
5. CONTRACTOR IS FINANCIALLY RESPONSIBLE TO ENSURE NOISE CONTROL SOLUTATION IS DELIVERED AS PER NC LEVELS IN THE SPACES SERVED BY THE SYSTEM ON WHICH THESE ATTENUATORS ARE INSTALLED,
4. SUBMIT FOR REVIEW BY ENGINEER. DO NOT PURCHASE WITHOUT WRITTEN REVIEW/ACCEPTANCE OF PERFORMANCE.
3. SILENCER MANUFACTURER MUST PROVIDE SILENCER INTERNAL GEOMETRY FOR ENGINEER'S APPROVAL DURING SUBMITTAL REVIEW.
2. SILENCER MANUFACTURER MUST PROVIDE SILENCER INTERNAL GEOMETRY FOR ENGINEER'S APPROVAL DURING SUBMITTAL REVIEW.
1. CONTRACTOR/SILENCER MANUFACTURER MUST PROVIDE ACOUSTICAL ANALYSIS WITH PE STAMP SHOWING SILENCER MEETS NC LEVELS LISTED BELOW DURING SUBMITTAL REVIEW.
NOTES:
SA-DOAU1-SA MECHANICAL PLATFORM DOAU-1 SUPPLY AIR 2215 20 X 14 0.20 DISSIPATIVE RECTANGULAR 20 14 96 14 18 24 37 27 20 15 13 PRICE RM96/XD
SA-AHU2-RA SIMULATOR BAY 109 AHU-2 RETURN AIR 6850 60 X 24 0.05 DISSIPATIVE RECTANGULAR 60 24 36 5 7 10 14 10 10 8 8 PRICE RH36/9A
SA-AHU1-RA MECHANICAL PLATFORM AHU-1 RETURN AIR 4720 30 X 20 0.12 DISSIPATIVE RECTANGULAR 30 20 36 7 11 16 23 18 13 11 8 PRICE RM36/9D
WIDTH HEIGHT LENGTH 63 125 250 500 1000 2000 4000 8000MARK LOCATION SERVES
RATED AIRFLOW
(CFM)
DUCT SIZE (W X H)
(IN)
MAX PD
(IN W.C.) TYPE CONFIGURAITON
SIZE (IN) MINIMUM dB / OCTAVE BAND ATTENUATION (HZ) BASIS OF
DESIGN
SOUND ATTENUATOR SCHEDULE
3. PROVIDE DUCT LEAKAGE CLASS OF 1/2" FOR DUCTWORK DOWNSTREAM OF VAV BOXES
IN SMACNA HVAC AIR DUCT LEAKAGE TEST MANUAL.
2. TEST IN ACCORDANCE WITH TESTING ADJUSTING, AND BALANCING FOR HVAC AND PROCEDURES
1. UTILIZE DUCT SEAL CLASS "A" FOR ALL DUCT SYSTEMS.
NOTES:
EXHAUST FAN - - -1 - - - 24 1.0
- - - -1 - - 24 1.0
DOAU-1
4 - - - 6 3 - 4.0
- -2 - - - - 24 2.0
AHU-3
4 - - - 6 6 - 4.0
- -2 - - - - 24 2.0
AHU-2
4 - - - 6 6 - 4.0
- -2 - - - - 24 2.0
AHU-1
4 - - - 6 3 - 4.0
RECTANGULAR ROUND
SUPPLY
AIR
RETURN
AIR
EXHAUST
AIR
OUTSIDE
AIR
SUPPLY RETURN/EXHAUST
/OUTSIDE AIRSYSTEM
DUCT PRESSURE CLASS (IN W.C.) DUCT LEAKAGE CLASS DUCT
PRESSURE
TEST (IN W.C.)
DUCT PRESSURE AND LEAKAGE CLASS SCHEDULE
1. HYDRONIC AND ELECTRICAL DATA SHOWN FOR SYSTEM SIZING. CSAC UNITS TO BE GFGI (GOVERNMENT FURNISHED GOVERNMENT INSTALLED).
NOTES:
CSAC-2 HH-60W SIMULATOR 60 45 55 12 15 208 3 60 10
CSAC-1 HC-130J SIMULATOR 120 45 55 24 15 480 3 60 15
CAPACITY (MBH) EWT (°F) LWT (°F)
FLOW
(GPM)
MAX.
ALLOWABLE
PRESSURE
DROP (FT)
VOLTAGE
(V) PHASE
FREQUENCY
(HZ) FLAMARK SERVES
CHILLED WATER COOLING COIL ELECTRICAL DATA
COCKPIT SIMULATOR AIR CONDITIONER (CSAC) SCHEDULE
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
N
O V
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
N
O V
W
2Q R
R
_P la ns -0
: ARIMS: 200A Disposition: Maintain for 15yrs after construction
| D3191903-AMENDMENT 0003-IF103 |
| Sheets |
| IF103 - FURNITURE, FIXTURE AND EQUIPMENT PLAN - LEVEL 1 - AREA B |
| D3191903-M-603 |
| Sheets |
| M-603 - MECHANICAL SCHEDULES |
File details come from the government source that posted it. Updated .