W912QR21R0051_Plans-0004.pdf
PDF 4 MB Posted
- Solicitation number
- W912QR21R0051
About this file
This document provides plans and specifications for laboratory renovations at Wright-Patterson Air Force Base in Ohio. The project involves renovations to the XTAL Building 654 with an estimated construction cost between $5-10 million. Drawings include demolition, architectural, mechanical, plumbing, fire alarm, and electrical plans. Products and services required include laboratory casework, flooring, wall finishes, HVAC equipment, plumbing fixtures, fire sprinklers, and electrical distribution. The pre-bid site visit will take place on July 1, 2021 and offers are due by July 26, 2021. The solicitation is full and open to all business sizes and includes a 10% price evaluation preference for HUBZone small businesses. The federal agency is the Department of the Army Corps of Engineers Engineering District Louisville.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
2 3 4 5 6 7 8
B
C
D
E
D08 D08 D08 D08
D08 D08
D08
D08
D08
D08
D08
D08
D08 D08
D04
D03
D03
D03
D03
D03
D03
D03
D03
D03
D03 D03
D03
D03
D03 D03
D03
5' - 4"
12' - 3 3/4"
D05
D05D05
D04
5' - 8"
D04
D17 D16 D17 D17
D17 D17
D17 D16 D17
D17
D17
DUCT SPACE
DUCT SPACE DUCT SPACE
D147 D148 D149 D150 D151 D152
D124D123D122D120D119
D147A
D119A D122A
D151A
D124A
D147B-1
D121
D08 D08
D08D08
D06
D02
D02
D120A
D149A
D03
D08
D08
FH
FH
FH
FH
FH
FH
FH
FH
DNUP
DNUP
D08 D04
3' - 4" 8" D08
D118
D16
7' - 6"
B8
AD102
D02
A B
D08
D08
D08
D08 D08
D08D08
D147B-2
D08 D08
D08 D08
D100
DUC09C
DUC10B DUC10C
DUC10DDUC10A
DUC09D DUC11A
DUC11B
DUC11C
DUC11D
FH
FH FH
D14
D14
D14
D14
D14
D14
D14
D14
D14 D14
D14
D14
D15
TYP. ABOVE CEILING
ENTIRE WALL
TYP. ABOVE CEILING
ENTIRE WALL
D15
D16
D06 D06
G01
BID OPTION
D16 D16
D16 D22
D22
D22D22
D22 D22
D22
D06
D06
D06
D06
D06
D06
EXISTING CONDITIONS SHOWN ON DRAWINGS ARE FOR INFORMATIONAL
PURPOSES ONLY AND DO NOT SHOW ALL CONDITIONS THAT MAY AFFECT THE
WORK OF THIS CONTRACT. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS BEFORE COMMENCING WORK. REFER TO ALL ARCHITECTURAL,
PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL
DEMOLITION INFORMATION AND COORDINATION. NOTIFY C.O.R. IMMEDIATELY OF
ANY DISCREPANCIES DETRIMENTAL TO THE PROPER EXECUTION OF NEW
CONSTRUCTION.
ALL DEMOLITION WORK SHALL COMPLY WITH APPLICABLE BUILDING CODE AND
ALL APPLICABLE LOCAL, STATE, AND FEDERAL LAWS, ORDINANCES, AND
REGULATIONS. SEE CODE SUMMARY SHEET FOR APPLICABLE BUILDING CODE.
REMOVE EXISTING CONSTRUCTION TO THE EXTENT INDICATED ON THE
DRAWINGS. PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE
THROUGHOUT DEMOLITION. SHOULD ANY DAMAGE OCCUR TO ANY EXISTING
CONSTRUCTION TO REMAIN, THE CONTRACTOR SHALL REPAIR THE DAMAGE TO
THE SATISFACTION OF THE PROPERTY OWNER.
EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED,
REINSTALLED, OR OTHERWISE INDICATED TO REMAIN THE OWNER’S PROPERTY,
DEMOLISHED MATERIALS SHALL BECOME THE CONTRACTOR’S PROPERTY AND
SHALL BE REMOVED FROM THE SITE WITH FURTHER DISPOSITION AT THE
CONTRACTOR’S OPTION.
EXISTING WALLS SHOWN GRAPHICALLY WITH SOLID LINES TO REMAIN. PREPARE
SURFACES TO RECEIVE NEW CONSTRUCTION OR FINISHES. SEE SHEET A-703.
ALL DEMOLISHED MATERIALS SHALL BE LEGALLY DISPOSED OF PROMPTLY. DO
NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON SITE. NO BURNING IS
ALLOWED.
GENERAL FLOOR PLAN DEMOLITION NOTES:
1.
2.
3.
4.
5.
6.
WHEN UNANTICIPATED MECHANICAL, ELECTRICAL, OR STRUCTURAL
ELEMENTS THAT CONFLICT WITH THE INTENDED FUNCTION OR DESIGN
ARE ENCOUNTERED, DETERMINE THE NATURE AND EXTENT OF THE
CONFLICT AND NOTIFY THE C.O.R. IMMEDIATELY FOR RESOLUTION.
THIS DEMOLITION PLAN OUTLINES THE SCOPE OF THE WORK INVOLVED
FOR THE DEMOLITION PHASE OF THIS PROJECT. CONTRACTOR SHALL
ALSO REFER TO THE DRAWINGS FOR THE CONSTRUCTION OF THE NEW
ADDITION FOR ADDITIONAL INFORMATION.
CONTRACTOR IS REQUIRED TO PERFORM ACTIVITIES AFTER HOURS IF
THE ACTIVITY PERFORMED IS CONSIDERED TO BE DISRUPTIVE TO THE
USER OR IMPEDES PATH OF TRAVEL FOR THE OCCUPANTS INCLUDING
HAZARDOUS MATERIAL ABATEMENT, FIRE ALARM TESTING, WALL
DEMOLITION, ENTRY DOOR DEMOLITION, QUARRY TILE REMOVAL AND
OTHER DEMOLITION INVOLVING THE USE OF EXCESSIVE NOISE
OPERATIONS. OTHER ACTIVITIES MAY ALSO APPLY IF THEY ARE
CONSIDERED DISRUPTIVE AND/OR INCLUDE EXCESSIVE NOISE
ALL FURNITURE WILL BE REMOVED OR RELOCATED BY THE OWNER AS
NECESSARY PRIOR TO THE DEMOLITION WORK OF THIS PROJECT.
ALL DEMOLITION WORK SHALL BE COORDINATED WITH NEW WORK OF
THIS PROJECT AS OUTLINED IN THE DOCUMENTS. ANY DISCREPANCIES
NOTED WHICH WILL IMPACT THE SCHEDULE FOR CONSTRUCTION OR
HAVE AN EFFECT ON THE CONTINUED OPERATION OF BUSINESS AT THIS
FACILITY SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE
C.O.R. FOR RESOLUTION.
WHEN UTILITY SERVICES ARE REQUIRED TO BE REMOVED, RELOCATED,
OR ABANDONED, PROVIDE BYPASS CONNECTIONS TO MAINTAIN
CONTINUITY OF SERVICE BEFORE PROCEEDING WITH DEMOLITION.
7.
8.
9.
10.
11.
12.
PRIOR TO COMMENCEMENT WITH ANY DEMOLITION WORK, CONTRACTOR SHALL
IDENTIFY ALL ELECTRICAL CIRCUITS SERVICING THE AREA INVOLVED WITH THIS
DEMOLITION. THOSE CIRCUITS SHALL THEN BE LOCKED OUT AND TAGGED OUT IF
THEY DO NOT SERVICE ANY OF THE REMAINING BUILDING. THOSE CIRCUITS
WHICH ARE IDENTIFIED TO SERVICE BOTH THE AREA TO BE DEMOLISHED AND
THE REMAINING BUILDING SHALL BE SPLIT SO AS TO KILL ALL ELECTRICAL
POWER TO THE AREA TO BE DEMOLISHED WHILE MAINTAINING POWER TO THE
REMAINDER OF THE BUILDING.
CARE SHOULD BE TAKEN TO KEEP DUST AND NOISE FROM DEMOLITION
ACTIVITIES FROM THE OTHER PORTIONS AND FLOORS OF THE BUILDING. ERECT
AND MAINTAIN DUST-PROOF PARTITIONS. SEE CONSTRUCTION ACCESS PLAN AND
SPECIFICATION SECTION "CLEANROOM CONSTRUCTION PROTOCOL."
PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION REQUIRED TO
PREVENT INJURY TO PEOPLE AND DAMAGE TO ADJACENT BUILDING AREAS TO
REMAIN.
NEATLY CUT OPENINGS AND HOLES PLUMB, SQUARE AND TRUE TO DIMENSIONS
REQUIRED. USE CUTTING METHODS LEAST LIKELY TO DAMAGE ADJOINING
CONSTRUCTION TO REMAIN.
PRIOR TO DEMOLITION, MAKE SURE PLUMBING IS CUT AND CAPPED AT ALL SINK
LOCATIONS, REMOVE CABINETRY, CASEWORK, SINKS, AND COUNTERTOPS.
REFERENCE MECHANICAL DRAWINGS FOR PLUMBING AND PIPES.
CONTRACTOR SHALL COMPLY WITH ALL NECESSARY FIRE SAFETY
REQUIREMENTS IN ACCORDANCE WITH CURRENTLY ADOPTED AND APPLICABLE
CODES.
SEE SHEET AD103 FOR ABOVE CEILING PLAN DEMOLITION INFORMATION.
13.
14.
15.
16.
17.
18.
19.
EXISTING DOOR
DOOR TO BE REMOVED
EXISTING WALL
WALL TO BE REMOVED
DEMOLITION / EXISTING PLAN LEGEND
NO ANTICIPATED WORK THIS AREA
FUME HOOD AND BASE CABINETS
TO BE REMOVED
FH
WALL / BASE CABINETS TO BE
REMOVED WITH ASSOCIATED
COUNTERTOPS AND UTILITIES
OR
LAB
LAB
LAB
147A
LAB
LAB
147B
UTILITY CORE
UC09
LAB
UTILITY CORE
UC10
LAB
LAB
LAB
LAB
LAB
LAB
LAB
LAB
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MEN'S TOILET
EAST CORRIDOR
UTILITY CORE
UC11
JANITOR
VESTIBULE
ELEC
TEL.
STAIR #1
S1
HYDR. ELEV.
E2
WOMEN'S TOILET
CLOSET
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONFERENCE ROOM
WEST CORRIDOR
ELEC. ELEV.
E1
CORRIDOR
STAIR #2
S2
STAIR #3
S3
1 2
B
REMOVE FLOORING AND MASTIC
RE: ENVIRONMENTAL PLAN AD101
AND SPECIFICATIONS
REMOVE EXTERIOR DOOR
D118
D119
D100
7' - 6"
3' - 4" 8"
11' - 0" 1' - 9"
REMOVE CMU AND PREP FOR NEW DOOR
REMOVE DOOR AND FRAME
LAB
OFFICE
EAST CORRIDOR
1.
DEMOLITION AND RECYCLING NOTES
ALL METAL AND WIRING SHALL BE RECYCLED AT THE WPAFB BASE
RECYCLING CENTER. THE WPAFB RECYCLING CENTER IS AVAILABLE FOR
CONTRACTOR USE TO REDUCE WASTE DISPOSAL. ALL RECYCLABLE METAL
IS TO BE RECYCLED THROUGH THE BASE RECYCLING CENTER. ALL
RECYCLING MUST BE ACCOMPLISHED IN ACCORDANCE WITH WPAFB
SPECIFICATION SECTION 01 35 43. CONTACT WPAFB RECYCLING PROGRAM
MANAGER AT 937-257-5060 TO CONFIRM WHAT MATERIALS ARE RECYCLABLE
AND TO COORDINATE TURN-IN. THE CONTRACTOR SHALL SUBMIT A
QUARTERLY SUMMARY REPORT TO THE GOVERNMENT CONTRACT
REPRESENTATIVE IAW WPAFB SPECIFICATION SECTION 01 35 43 STATING (1)
THE COST TO RECYCLE AND THE TONNAGE OF CONSTRUCTION AND
DEMOLITION MATERIALS RECYCLED, (2) THE COST TO DIVERT/REUSE THE
TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS
DIVERTED/REUSE, (3) THE COST TO MULCH AND THE TONNAGE AND COST
OF CONSTRUCTION AND DEMOLITION MATERIALS MULCHED, (4) THE COST
FOR WASTE-TO-ENERGY AND THE TONNAGE OF CONSTRUCTION AND
DEMOLITION MATERIALS CONVERTED FROM WASTE-TO-ENERGY, (5) THE
COST TO LANDFILL AND THE TONNAGE OF CONSTRUCTION AND DEMOLITION
MATERIALS LAND-FILLED, (6) THE COST TO INCINERATE AND THE TONNAGE
OF CONSTRUCTION AND DEMOLITION MATERIALS INCINERATED, AND (7)
EXPLANATION OF THE DIVERSION RATE IF LESS THAN 60%. THE QUARTERLY
SUMMARY REPORTS SHALL BE RECEIVED ON APRIL 7, JULY 7, OCTOBER 7,
AND JANUARY 7 COVERING THE THREE MONTHS PRIOR. THE QUARTERLY
SUMMARY REPORTS SHALL BE ON THE WPAFB DIVERSION FORM. FOR
ADDITIONAL INFORMATION CONTACT THE RECYCLING PM, DAVE DALTON, AT
937-257-5060 OR DAVID.DALTON.2@US.AF.MIL.
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
A B
KEY PLAN
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
K
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
P N
SHEET ID
C E
R T
IF
IE
D F
IN
A
L
2 864 10
E
F
G
N.T.S.
NORTH
A s i n d ic a te d
AD102
C B
A R
D
N C
O H
E N
C B
A R
D
/2
/2
Z H
T V
W P
A F
B X
T A
L
Z H
T V
W P
A F
B X
T A
L R
E N
O V
A T
IO
N
F
IR
S T
F L O
O R
D E
M O
L
IT
IO
N
P L A
N
A R
E A
A
W R
IG
H
T -P
A T
T E
R S
O N
A F
B
O H
SCALE: 1/8" = 1'-0"C1
FIRST FLOOR DEMOLITION PLAN - AREA A
SCALE IN FEET
0 4' 8' 16'
KEYNOTE LEGEND DEMOLITION
# DESCRIPTION
D02 CASEWORK TO BE REMOVED. COORDINATE REMOVAL WITH UTILITIES.
D03 6" NOMINAL CMU WALL TO BE REMOVED FULL HEIGHT
D04 6" NOMINAL CMU WALL TO BE REMOVED TO ALLOW INSTALLATION OF NEW DOOR. COORDINATE MASONRY OPENING WITH NEW
DOOR ROUGH OPENING REQUIREMENTS. SEE NEW LINTEL DETAIL SHEET A-511.
D05 PLATE STEEL PARTITION TO BE REMOVED. COORDINATE WITH UTILITIES IN CHASE.
D06 EQUIPMENT TO BE REMOVED. COORDINATE WITH UTILITIES
D08 DOOR AND FRAME TO BE REMOVED
D14 REMOVE ABANDONED UTILITIES THROUGH PARTITION AND ANY ASSOCIATED INFILL OR FIRESTOPPING. PREP OPENING FOR
NEW INFILL OR FIRESTOPPING. COORDINATE WITH NEW WORK
D15 REMOVE ABANDONED UTILITIES THROUGH PARTITION ABOVE CEILING AND ANY ASSOCIATED INFILL OR FIRESTOPPING. PREP
OPENING FOR NEW INFILL OR FIRESTOPPING. COORDINATE WITH NEW WORK
D16 VINYL FLOORING AND MASTIC TO BE REMOVED. SEE ACM REMOVAL SPECIFICATIONS
D17 QUARRY TILE FLOORING TO BE REMOVED. CLEAN AND PREP FLOOR FOR LEVELING (OR CONCRETE TOPPING IF REQUIRED) AND
NEW FINISH. SEE GENERAL NOTE 16 DRAWING A-101 FOR LEVELING PRODUCT REQUIREMENTS.
D22 REMOVE UTILITY CHASE AND ASSOCIATED UTILITIES BACK TO SOURCE. COORDINATE WITH MECHANICAL AND ELECTRICAL
DEMOLITION WORK
G01 BID OPTION: VEST & UTILITY CORE LTG. INCLUDES ALL EQUIPMENT AND CONSTRUCTION WORK FOR THE INSTALLATION OF A VESTIBULE INSIDE OF THE NORTHEAST DOOR OF THE FIRST FLOOR (INCLUDING REPLACEMENT OF THE EXTERIOR DOOR, RELOCATION OF EXISTING OFFICE DOOR, AND INSTALLATION OF UNIT HEATER AND ASSOCIATED PIPING) AND WIRING REVISIONS TO THE CORE LIGHTING PER THE CONTRACT DOCUMENTS. CHANGING OUT OF THE FIXTURES IN THE UTILITY CORES
IS PART OF THE BASE BID.
NORTH
SCALE: 1/4" = 1'-0"B8
DEMOLITION PLAN - BID OPTION
SCALE IN FEET
0 2' 4' 8'
NORTH
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
M A
Y
IN
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
J U
L
7/28/21
W
2Q R
R
-0 amartinezrenteria Snapshot amartinezrenteria Snapshot
2 3 4 5 6 7
B
C
D
E
WEST CORRIDOR
SEM ROOM
LITHO PREP BAY
LITHO SUPPORT
ROOM
149A
ANTEROOM
148A
ETCH & DEP
SUPPORT
148C
GOWNING ROOM
UTILITY CORE (EXIST)
UC10
UTILITY CORE (EXIST)
UC09
UTILITY CORE (EXIST)
UC11
SURFACE SCIENCE
WEST
SURFACE SCIENCE
SUPPORT
152A
LITHO BAY
ETCH & DEP BAY
148B
MBE SUPPORT
121A
NEXT GEN MBE LAB
STRUCTURAL
CHARACTERIZATION
SURFACE SCIENCE
EAST
As MBE LAB
MECHANICAL ROOM
EAST CORRIDOR
VESTIBULE
A4
A-001
A1
A-001
A B
1 1
ABOVE
ZONE A
ZONE B
ZONE CZONE C ZONE C
ZONE B
A B
6 6
COORDINATE AIR BARRIER INSTALLATION WITH SPECIFICATION SECTIONS 13 21 13
CLEANROOMS, 13 21 13.10 CLEANROOM CONSTRUCTION PROTOCOL, AND 13 21 13.20
CLEANROOM CERTIFICATION AND ACCEPTANCE.
SEE SPECIFICATION SECTION 07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM.
SEE SPECIFICATION SECTIONS 07 27 26 FLUID APPLIED MEMBRANE AIR BARRIERS AND
07 27 19.01 SELF-ADHERING AIR BARRIERS AND OTHER APPLICABLE SECTIONS.
SEAL AROUND ALL FLOOR, WALL AND UNDERSIDE OF SECOND FLOOR SLAB.
PROVIDE A SIX-SIDED, CONTINUOUS AIR BARRIER AT CLEAN PERIMETER.
GENERAL CLEANROOM AIR BARRIER NOTES:
1.
2.
3.
4.
5.
SIX-SIDED AIR AND VAPOR TIGHT PERIMETER FOR THE CLEANROOM USING SYSTEM
MANUFACTURER'S STANDARD DETAILS USING MATERIAL COMPATIBLE WITH
SUBSTRATES AND APPROPRIATE FOR TRANSITIONS AT ALL INSIDE AND OUTSIDE
CORNERS.
CLEANROOM CONTINUOUS AIR BARRIER DEFINITION:
2 SHEET FLOORING WITH WELDED SEAMS AT AREAS EXPOSED TO VIEW (CLEAN
ROOM). AT RETURN AIR PLENUM SPACES, PROVIDE SEALED CONCRETE FLOOR
FINISH.
1 FLUID-APPLIED AIR BARRIER ON CMU
3 FLUID-APPLIED AIR BARRIER ON CAST-IN-PLACE CONCRETE ROOF / CEILING
4 FLUID-APPLIED AIR BARRIER ON GYPSUM BOARD ON METAL STUD
5 FLUID-APPLIED AIR BARRIER ON CAST-IN-PLACE CONCRETE STRUCTURE
AIR BARRIER KEY:
6 NO AIR BARRIER WORK
CLEANROOM AIR BARRIER ZONE LEGEND
AREAS LISTED BELOW ARE ROUGH ESTIMATES. CONTRACTOR MUST
FIELD VERIFY ALL ZONE AREAS AND ADJUST CALCULATIONS FOR
MAXIMUM LEAKAGE CFM AS REQUIRED.
ALLOWABLE LEAKAGE RATE = 0.40 CFM/SF
AIR BARRIER LOCATION
ZONE A - CLEANROOM - ISO 5 AND ISO 6
FLOOR AREA =
WALL AREA =
ROOF AREA =
1,950 SF
3,400 SF
1,950 SF
7,300 SF x 0.40 = 2,920 CFM
(MAX LEAKAGE)
ZONE B - GENERAL LABS - NOT CLASSIFIED
NO AIR BARRIER WORK
ZONE C - UTILITY CORES - NOT CLASSIFIED
NO AIR BARRIER WORK
FIRST FLOOR
100' - 0"
A
SECOND FLOOR
114' - 8"
B C D E
ZONE AZONE C
ZONE BZONE B
66 6
FIRST FLOOR
100' - 0"
SECOND FLOOR
114' - 8"
2 3 4 5 6 7
ZONE BZONE A
ZONE B
6 6
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MEN'S TOILET
JANITOR
VESTIBULE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONFERENCE ROOM
CORRIDOR
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
A B
KEY PLAN
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
P N
SHEET ID
C E
R T
IF
IE
D F
IN
A
L
2 864 10
E
F
G
N.T.S.
NORTH
A s i n d ic a te d
A-001
C B
A R
D
N C
O H
E N
C B
A R
D
/2
/2
Z H
T V
W P
A F
B X
T A
L
Z H
T V
W P
A F
B X
T A
L R
E N
O V
A T
IO
N
A
IR
B A
R R
IE
R
P L A
N
W R
IG
H
T -P
A T
T E
R S
O N
A F
B
O
HSCALE: 1/8" = 1'-0"B1
AIR BARRIER PLAN
SCALE: 3/32" = 1'-0"A1
AIR BARRIER SECTION - EAST / WEST
SCALE: 3/32" = 1'-0"A4
AIR BARRIER SECTION - NORTH / SOUTH
SCALE IN FEET
0 4' 8' 16'
SCALE IN FEET
0 8' 16' 24'
SCALE IN FEET
0 8' 16' 24'
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
M A
Y
IN
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
J U
L
7/28/21
W
2Q R
R
-0 amartinezrenteria Snapshot
2 3 4 5 6 7 8
B
C
D
E
UC09B
UC09A
MECHANICAL ROOM
STRUCTURAL
CHARACTERIZATION
As MBE LAB
SURFACE SCIENCE
SUPPORT
152A
NEXT GEN MBE LAB
LITHO SUPPORT
ROOM
149A
MBE SUPPORT
121A
LITHO PREP BAY
LITHO BAY
ETCH & DEP BAY
148B
GOWNING ROOM
WEST CORRIDOR
EAST CORRIDOR
VESTIBULE
SURFACE SCIENCE
EAST
122-1119
RETURN AIR
RETURN AIR RETURN AIR
A40
34' - 5" 14' - 6 1/2" 17' - 2 3/4" 18' - 7"
DUCT SPACE
DUCT SPACE DUCT SPACE
12' - 4 1/4" 5' - 9" 8' - 8" 17' - 2" 15' - 6"
/2
A7
A-311
A3
A-311
A1
A-311
A5
A-311
DNUP
DNUP
1' - 9"
W01 W01
SURFACE SCIENCE
WEST
SEM ROOM
ETCH & DEP
SUPPORT
148C
ANTEROOM
148A
149A-1
148C-1
148A
148B
A40
152A-1
152A-2
122-2
121A
RETURN AIR
A1
A-111
BID OPTION
RETURN AIR
A35
A35
148C-2
149A-2
" 1
/2
10' - 4 1/4"
/4
/2
A05
A32
A05
A05 A05A05
TYP. CLEAN SIDE
KEYNOTE A33 APPLIES TO ALL AREAS
REQUIRING QUARRY TILE DEMOLITION.
REFERENCE KEYNOTE D17 DWG. AD102
FOR APPLICABLE AREAS.
A32
UC09C
UC09D
UC10B
UC10C
UC10A
UC11B UC11C
UC11DUC11AUC10D
W02 W02
160-1
160-2
A-751C1
A-751
A1
A-751 A4
A-751C4
A-751
A1
A B
A-751C8
5' - 1 1/2"
2' - 3 1/4"
13' - 3 3/4"
/4
/4
8' - 8 1/4" 10 1/4"
4' - 3" 4' - 0 1/2" 2' - 1 1/2" 4' - 3"
/4
1' - 4 1/4"
A05
A05
A05
A05
A05
A05
A05
7' - 2 3/4" 5' - 4" 5' - 4" 1' - 2"
4' - 6"
RETURN AIR
A05
A05
A05
B7
AG003
B7
AG003
G01
5' - 5 3/4"
7' - 10"
SEE SHEET A-131 FOR CLEANROOM FRAMING AND ADDITIONAL DIMENSIONS
A54
A54
A54
A55 A55
SF01
A33
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
FOR ARCHITECTURAL GENERAL NOTES SHEET AG002. FOR MATERIAL LEGEND
AND ABBREVIATIONS REFER TO SHEET AG001.
REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS
ARE CONTINUOUS ACROSS ALL DOOR OPENINGS.
FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION
REFER TO PARTITION TYPES SHEET.
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS
AND SITE CONDITIONS BEFORE BEGINNING WORK AND
FABRICATION. THE OWNER SHALL BE NOTIFIED IN WRITING
IMMEDIATELY OF ANY DISCREPANCIES OR INCONSISTENCIES.
IN NO CASE SHALL DIMENSIONS BE SCALED OFF PLANS, SECTIONS,
OR DETAILS FROM THESE DRAWINGS.
FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
DOOR LOCATIONS NOT DIMENSIONED ARE 6 INCHES FROM FACE
OF GYPSUM BOARD FINISH WALL TO DOOR JAMB FACE. VERIFY
THERE IS A PULL SIDE MINIMUM 18 INCHES CLEAR FROM DOOR
STRIKE TO INTERSECTING WALL FOR ABAAS COMPLIANCE. NOTIFY
C.O.R. FOR NON-COMPLIANCE BEFORE SETTING
DOOR FRAME AND WALL LOCATIONS.
CONTRACTOR SHALL COORDINATE AND PROVIDE ALL MILLWORK
TRIM AND INFILL PANELS AT ALL UNDERCOUNTER / CABINET
LOCATIONS.
REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL
FINISH INFORMATION. ALL FLOOR FINISHES TO BE CONTINUOUS
UNDER MILLWORK AND EQUIPMENT UNLESS NOTED OTHERWISE.
PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING
IN WALL FOR ACCESSORIES, EQUIPMENT, AND COUNTERTOP
MOUNTING SUPPORTS.
REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL,
FINISH FACE OF METAL STUD WALL, UNLESS NOTED OTHERWISE.
THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS
NOTED OTHERWISE.
PROVIDE GYPSUM BOARD HEADER ABOVE ALL CASED OPENINGS,
REFERENCE REFLECTED CEILING PLANS.
REFERENCE FURNITURE PLANS FOR LOCATIONS OF WALL
ACCESSORIES AND VISUAL DISPLAY EQUIPMENT.
PROVIDE BLOCKING AS REQUIRED
SEE SHEET A-102 FOR ABOVE CEILING PLAN INFORMATION.
LEVELING COURSE FOR CONCRETE SHALL CONSIST OF A FAST-SETTING SELF-LEVELING CEMENT-BASED PRODUCT FOR UP TO 1" IN THICKNESS. FLEXURAL STRENGTH PER ASTM C348 OF 1200 PSI IN 28 DAYS. COMPRESSIVE STRENGTH PER ASTM C109 OF 7000 PSI IN 28 DAYS. SUITABLE FOR FOOT TRAFFIC AND LIGHT INDUSTRIAL APPLICATIONS. PRIME CLEAN SUBSTRATE AND INSTALL PRODUCT PER MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. INSTALL EXPANSION JOINTS AT ALL RESTRAINING SURFACES INCLUDING PERIMIETER WALLS, COLUMN BASES, ETC.
EXISTING DOOR
NEW DOOR
EXISTING WALL
NEW WALL
(RE: PARTITION TYPE)
PLAN LEGEND:
ROOM NAME
ROOM NUMBER
PARTITION TYPE
DOOR NUMBER
WINDOW WALL TYPE
(STOREFRONT)
GRID BUBBLE AND LINE
ROOM NAME
S2AA
SF01
CLEANROOM PARTITION
SYSTEM (CRPS)
NO ANTICIPATED WORK THIS AREA
ISO 5 CLEANROOM AREA
ISO 6 CLEANROOM AREA
W01 WINDOW TYPE
UTILITY CORE
UC09
UTILITY CORE
UC10
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MEN'S TOILET
UTILITY CORE
UC11
JANITOR
VESTIBULE
ELEC
TEL.
STAIR #1
HYDR. ELEV.
WOMEN'S TOILET
CLOSET
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONFERENCE ROOM
ELEC. ELEV.
CORRIDOR
STAIR #2
S2
STAIR #3
S3
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
A B
KEY PLAN
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
P N
SHEET ID
C E
R T
IF
IE
D F
IN
A
L
2 864 10
E
F
G
N.T.S.
NORTH
/8
A-101
C B
A R
D
N C
O H
E N
C B
A R
D
/2
/2
Z H
T V
W P
A F
B X
T A
L
Z H
T V
W P
A F
B X
T A
L R
E N
O V
A T
IO
N
F
IR
S T
F L O
O R
P L A
N
A R
E A
A
W R
IG
H
T -P
A T
T E
R S
O N
A F
B
O H
SCALE: 1/8" = 1'-0"C1
FIRST FLOOR DIMENSION PLAN - AREA A
SCALE IN FEET
0 4' 8' 16'
KEYNOTE LEGEND FLOOR PLAN
# DESCRIPTION
A05 EXISTING WORK THROUGH EXISTING MASONRY WALL. REPAIR OR REPLACE FIRESTOPPING AS REQUIRED.
A32 EPOXY PAINT FINISH. FILL VOIDS IN CMU SMOOTH AND LET CURE PRIOR TO PAINTING. TYP. CLEANROOM SIDE.
A33 CONCRETE TOPPING (IF REQUIRED). FIELD VERIFY REQUIRED LOCATION AND DEPTH. TYPICAL AT ROOMS REQUIRING QUARRY TILE DEMOLITION. PRIME EXISTING CAST-IN-PLACE FLOOR SLAB AND POUR LEVEL, SMOOTH, AND FLUSH WITH ADJACENT CONSTRUCTION. REINFORCE WITH WWM 6 X 6 - W1.4 X W1.4
A35 PLUMBING FIXTURE. RE: PLUMBING SHEETS
A40 CLEANROOM SAMPLE PASS BOX
A54 INSTALL NEW UV LIMITING FILM ON CLEANROOM SIDE OF WINDOW OR DOOR GLAZING FOLLOWING MANUFACTURERS RECOMMENDED INSTALLATION METHOD AND PRODUCTS. RE: GLAZING SPECIFICATIONS FOR ACCEPTABLE PRODUCTS AND MANUFACTURERS. COORDINATE UV SPECTRUM REQUIREMENTS WITH END USER.
A55 INSTALL NEW UV LIMITING FILM ON NON-CLEANROOM SIDE OF WINDOW OR DOOR GLAZING FOLLOWING MANUFACTURERS RECOMMENDED INSTALLATION METHOD AND PRODUCTS. RE: GLAZING SPECIFICATIONS FOR ACCEPTABLE PRODUCTS AND MANUFACTURERS. COORDINATE UV SPECTRUM REQUIREMENTS WITH END USER.
G01 BID OPTION: VEST & UTILITY CORE LTG. INCLUDES ALL EQUIPMENT AND CONSTRUCTION WORK FOR THE INSTALLATION OF A VESTIBULE INSIDE OF THE NORTHEAST DOOR OF THE FIRST FLOOR (INCLUDING REPLACEMENT OF THE EXTERIOR DOOR, RELOCATION OF EXISTING OFFICE DOOR, AND INSTALLATION OF UNIT HEATER AND ASSOCIATED PIPING) AND WIRING REVISIONS TO THE CORE LIGHTING PER THE CONTRACT DOCUMENTS. CHANGING OUT OF THE FIXTURES IN THE UTILITY CORES IS PART OF THE BASE BID.
NORTH
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
M A
Y
IN
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
J U
L
7/28/21
W
2Q R
R
-0 amartinezrenteria Snapshot
2 3 4 5 6 7 8
B
C
D
E
A7
A-311
A3
A-311
A1
A-311
A5
A-311
UC09B
UC09A
MECHANICAL ROOM
STRUCTURAL
CHARACTERIZATION
As MBE LAB
SURFACE SCIENCE
SUPPORT
152A
NEXT GEN MBE LAB
LITHO SUPPORT
ROOM
149A
MBE SUPPORT
121A
LITHO PREP BAY
150LITHO BAY
ETCH & DEP BAY
148B
GOWNING ROOM
WEST CORRIDOR
EAST CORRIDOR
156VESTIBULE
SURFACE SCIENCE
EAST
122-1119
M1BB M1BB
M1BB
M1BB
M1BBM1BB
CRPS-1
CRPS-1 CRPS-1
CRPS-1
CRPS-1
S3AA
S3AA
S3AA
S2AH
S3AA
S2AA
CRPS-1
M1BBM1BB
CRPS-1CRPS-1CRPS-1
DUCT SPACE
DUCT SPACE DUCT SPACE
CRPS-1CRPS-1
DNUP
DNUP
M1BC
ABOVE AND BELOW ABOVE AND BELOW
W01 W01
SURFACE SCIENCE
WEST
SEM ROOM
ETCH & DEP
SUPPORT
148C
ANTEROOM
148A 149A-1
148C-1148A
148B
152A-1
152A-2
122-2
121A
CRPS-1
BID OPTION
S3AC
S3AC
S2AH
S2AH
S2AA
S2AA
S2AA
S2AA
S2AA
S2AA
F1CA
CRPS-1
CRPS-1
CRPS-1CRPS-1
CRPS-1
A1
A-111
S3AA
UC09C
UC09D
UC10B UC10C
UC10DUC10A
149A-2
W02W02
UC11B UC11C
UC11DUC11A
148C-2
160-2
F1CA
F1CA
M1BA
F1CBS2AA
F1CB
F1CB
F1CB
F1CA
S2AA
S2AA
S2AA
S2AH
" S2AA
8' - 0"
S2AA
8' - 0"
S2AA
S3AD
S3AC
A-751C1
A-751
A1
A-751 A4
A-751C4
A B
A-751C8
A-751
A1
CRPS-2
CRPS-2 CRPS-2
SF01
160-1
S2AF
ABOVE
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
FOR ARCHITECTURAL GENERAL NOTES SHEET AG002. FOR MATERIAL LEGEND
AND ABBREVIATIONS REFER TO SHEET AG001.
REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS
ARE CONTINUOUS ACROSS ALL DOOR OPENINGS.
FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION
REFER TO PARTITION TYPES SHEET.
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS
AND SITE CONDITIONS BEFORE BEGINNING WORK AND
FABRICATION. THE OWNER SHALL BE NOTIFIED IN WRITING
IMMEDIATELY OF ANY DISCREPANCIES OR INCONSISTENCIES.
IN NO CASE SHALL DIMENSIONS BE SCALED OFF PLANS, SECTIONS,
OR DETAILS FROM THESE DRAWINGS.
FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
DOOR LOCATIONS NOT DIMENSIONED ARE 6 INCHES FROM FACE
OF GYPSUM BOARD FINISH WALL TO DOOR JAMB FACE. VERIFY
THERE IS A PULL SIDE MINIMUM 18 INCHES CLEAR FROM DOOR
STRIKE TO INTERSECTING WALL FOR ABAAS COMPLIANCE. NOTIFY
C.O.R. FOR NON-COMPLIANCE BEFORE SETTING
DOOR FRAME AND WALL LOCATIONS.
CONTRACTOR SHALL COORDINATE AND PROVIDE ALL MILLWORK
TRIM AND INFILL PANELS AT ALL UNDERCOUNTER / CABINET
LOCATIONS.
REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL
FINISH INFORMATION. ALL FLOOR FINISHES TO BE CONTINUOUS
UNDER MILLWORK AND EQUIPMENT UNLESS NOTED OTHERWISE.
PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING
IN WALL FOR ACCESSORIES, EQUIPMENT, AND COUNTERTOP
MOUNTING SUPPORTS.
REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL,
FINISH FACE OF METAL STUD WALL, UNLESS NOTED OTHERWISE.
THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS
NOTED OTHERWISE.
PROVIDE GYPSUM BOARD HEADER ABOVE ALL CASED OPENINGS,
REFERENCE REFLECTED CEILING PLANS.
REFERENCE FURNITURE PLANS FOR LOCATIONS OF WALL
ACCESSORIES AND VISUAL DISPLAY EQUIPMENT.
PROVIDE BLOCKING AS REQUIRED
SEE SHEET A-102 FOR ABOVE CEILING PLAN INFORMATION.
LEVELING COURSE FOR CONCRETE SHALL CONSIST OF A FAST-SETTING SELF-LEVELING CEMENT-BASED PRODUCT FOR UP TO 1" IN THICKNESS. FLEXURAL STRENGTH PER ASTM C348 OF 1200 PSI IN 28 DAYS. COMPRESSIVE STRENGTH PER ASTM C109 OF 7000 PSI IN 28 DAYS. SUITABLE FOR FOOT TRAFFIC AND LIGHT INDUSTRIAL APPLICATIONS. PRIME CLEAN SUBSTRATE AND INSTALL PRODUCT PER MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. INSTALL EXPANSION JOINTS AT ALL RESTRAINING SURFACES INCLUDING PERIMIETER WALLS, COLUMN BASES, ETC.
EXISTING DOOR
NEW DOOR
EXISTING WALL
NEW WALL
(RE: PARTITION TYPE)
PLAN LEGEND:
ROOM NAME
ROOM NUMBER
PARTITION TYPE
DOOR NUMBER
WINDOW WALL TYPE
(STOREFRONT)
GRID BUBBLE AND LINE
ROOM NAME
S2AA
SF01
CLEANROOM PARTITION
SYSTEM (CRPS)
NO ANTICIPATED WORK THIS AREA
ISO 5 CLEANROOM AREA
ISO 6 CLEANROOM AREA
W01 WINDOW TYPE
UTILITY CORE
UC09
UTILITY CORE
UC10
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MEN'S TOILET
UTILITY CORE
UC11
JANITOR
VESTIBULE
ELEC
TEL.
STAIR #1
HYDR. ELEV.
WOMEN'S TOILET
CLOSET
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONFERENCE ROOM
ELEC. ELEV.
CORRIDOR
STAIR #2
S2
STAIR #3
S3
1 2
B
M1BA
SF01
M1BC
160-1
160-2
3' - 4" 8"
A-681 C7
SURFACE
WALK-OFF MAT
EAST CORRIDOR
OFFICE (EXIST)
VESTIBULE
MECHANICAL ROOM
7' - 0"
/2
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
A B
KEY PLAN
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
P N
SHEET ID
C E
R T
IF
IE
D F
IN
A
L
2 864 10
E
F
G
N.T.S.
NORTH
A s i n d ic a te d
A-111
C B
A R
D
N C
O H
E N
C B
A R
D
/2
/2
Z H
T V
W P
A F
B X
T A
L
Z H
T V
W P
A F
B X
T A
L R
E N
O V
A T
IO
N
F
IR
S T
F L O
O R
P A
R T
IT
IO
N T
Y P
E P
L A
N
A R
E A
A
W R
IG
H
T -P
A T
T E
R S
O N
A F
B
O H
SCALE: 1/8" = 1'-0"C1
FIRST FLOOR PARTITION TYPES PLAN - AREA A
SCALE IN FEET
0 4' 8' 16'
NORTH
SCALE: 1/4" = 1'-0"A1
FLOOR PLAN - BID OPTION
SCALE IN FEET
0 4' 8' 16'
NORTH
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
M A
Y
IN
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
J U
L
7/28/21
W
2Q R
R
-0 amartinezrenteria Snapshot
SEE ROOM FINISH SCHEDULE
FOR FINISH MATERIALS OVER
GYPSUM BOARD
SCHEDULED CEILING
1 LAYER OF MOISTURE
RESISTANT 5/8" TYPE "X"
GYPSUM BOARD EACH SIDE OF
METAL STUDS @ 16" O.C.
PARTITION TYPE S2
SEE HEAD DETAIL IN
SCHEDULE BELOW
INSULATION AS REQUIRED.
SEE SCHEDULE BELOW
SEE BASE DETAIL IN
SCHEDULE BELOW
HEAD
CEILING
PLAN
BASE
STANDARD CONCRETE
MASONRY UNIT (CMU)
SCHEDULED CEILING
VERTICAL REINFORCEMENT. #4 BARS AT 48"
O.C. CENTERED IN GROUTED CELL
PARTITION TYPE M1
SEE HEAD DETAIL IN
SCHEDULE BELOW
SEE BASE DETAIL IN
SCHEDULE BELOW
HEAD
CEILING
PLAN
BASE
SEE ROOM FINISH SCHEDULE
FOR FINISH MATERIALS OVER
GYPSUM BOARD
SCHEDULED CEILING
2 LAYERS OF MOISTURE
RESISTANT 5/8" TYPE "X"
GYPSUM BOARD ONE SIDE OF
METAL STUDS @ 16" O.C.
PARTITION TYPE S3
SEE HEAD DETAIL IN
SCHEDULE BELOW
INSULATION AS REQUIRED.
SEE SCHEDULE BELOW
SEE BASE DETAIL IN
SCHEDULE BELOW
HEAD
CEILING
PLAN
BASE
1 LAYER OF MOISTURE
RESISTANT 5/8" TYPE "X"
GYPSUM BOARD ONE SIDE OF
METAL STUDS @ 16" O.C.
SEE ROOM FINISH SCHEDULE
FOR FINISH MATERIALS OVER
GYPSUM BOARD
SCHEDULED CEILING
1 LAYER OF 5/8" MOISTURE RESISTANT
GYPSUM BOARD ON METAL FURRING, SEE
"TYPE COMMENTS" BELOW
PARTITION TYPE F1
SEE HEAD DETAIL IN
SCHEDULE BELOW
SEE BASE DETAIL IN
SCHEDULE BELOW
HEAD
CEILING
PLAN
BASE
HORIZONTAL JOINT REINFORCEMENT AT FIRST
AND EVERY OTHER JOINT TO TOP OF WALL
HORIZONTAL JOINT REINFORCEMENT AT FIRST
AND EVERY OTHER JOINT TO TOP OF WALL
SCHEDULED CEILING
CRCS-1 OR CRCS-2
SEE HEAD
DETAIL F1 / A-515
SEE BASE DETAIL
A1 AND C8 SHEET A-515
HEAD
CEILING
PLAN
BASE
SEE PLAN DETAILS
SHEET A-515
PARTITION TYPE CRPS-1
SCHEDULED CEILING
CRCS-1 OR CRCS-2
SEE HEAD DETAIL
C5 / A-516
SEE BASE DETAIL
C5 / A-516
HEAD
CEILING
PLAN
BASE
SEE PLAN DETAILS
SHEET A-516
PARTITION TYPE CRPS-2
PARTITION TYPES GENERAL NOTES:
WHERE ITEMS PENETRATE FIRE-RATED GYPSUM BOARD WALLS, TAPE & SEAL WITH
FIRE STOPPING SEALANT. WHERE ITEMS PENETRATE FIRE-RATED CMU OR CONCRETE
WALLS, SEAL WITH FIRE STOPPING SEALANT.
PROVIDE MINIMUM 20 GAUGE METAL BACKING AS REQUIRED FOR
INSTALLATION OF EXTINGUISHER CABINETS, MESSAGE BOARDS, WALL AND BASE
CABINETS, ACCESS PANELS, ELECTRICAL AND FIRE PROTECTION SYSTEM PANELS,
UNLESS NOTED OTHERWISE.
ALL METAL STUDS AND BRACING SHALL BE 20 GAUGE UNLESS NOTED
OTHERWISE. REFERENCE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
REFERENCE DRAWINGS A-113 FOR PARTITION TYPE LOCATIONS.
SEE DRAWING A-521 FOR TYPICAL PENETRATION DETAILS THROUGH
FIRE-RATED PARTITIONS.
FOR CLEANROOM PARTITIONS CRPS-1 AND CRPS-2, REFER TO SHEETS A-515 AND A-516
AS WELL AS THE REQUIREMENTS IN SPECIFICATION SECTION 13 21 13, 13 21 13.10, AND
13 21 13.20
AT CLEAN SIDE OF NEW OR EXISTING WALLS, SEAL TIGHT TO FLOOR, CEILING, AND
ADJACENT CONSTRUCTION WITH SPECIFIED CONTINUOUS AIR BARRIER. SEAL AIR-
TIGHT AROUND ALL PENETRATIONS THROUGH CLEAN PERIMETER WALLS WITH
FLEXIBLE, SELF ADHERING AND / OR FLUID APPLIED AIR BARRIER SYSTEM.
1.
2.
3.
4.
5.
6.
7.
PARTITION TYPE SYMBOL LEGEND:
S1AA
INDICATES TYPE OF
PARTITION STRUCTURE:
F = FURRING METAL STUD
S = METAL STUD
H = C-H METAL STUD
M = MASONRY
INDICATES NUMBER OF
LAYERS OF GYPSUM BOARD
OR TYPE OF CMU FINISH
INDICATES THICKNESS OF
PARTITION STRUCTURE
INDICATES VARIATION OF
PARTITION WITH THE SAME
STRUCTURE, FINISH, AND
STRUCTURE THICKNESS
PARTITION TYPE
SYMBOL {
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
P N
SHEET ID
C E
R T
IF
IE
D F
IN
A
L
2 864 10
E
F
G
A s i n d ic a te d
A-501
C B
A R
D
N C
O H
E N
A M
A R
T
IN
E Z
/2
/2
Z H
T V
W P
A F
B X
T A
L
Z H
T V
W P
A F
B X
T A
L R
E N
O V
A T
IO
N
P A
R T
IT
IO
N T
Y P
E S
W R
IG
H
T -P
A T
T E
R S
O N
A F
B
O H
TYPE STC
FIRE
RATING
UL DESIGN
NO
HEAD
DETAIL
BASE
DETAIL TYPE COMMENTS
S2AA - - - E3 / A-511 C3 / A-511 3 5/8" METAL STUDS WITH BLANKET INSULATION.
S2AF - - - E1 / A-511 E5 / A-561 3 5/8" METAL STUDS WITHOUT BLANKET INSULATION. PARTIAL HEIGHT
SUSPENDED FROM OVERHEAD STRUCTURE.
S2AH - - A8 / A-511 C3 / A-511 3 5/8" METAL STUDS, PARTIAL HEIGHT WALL WITH BLANKET INSULATION. WALL
STOPS 4" ABOVE FINISHED CEILING
TYPE STC
FIRE
RATING
UL DESIGN
NO
HEAD
DETAIL
BASE
DETAIL TYPE COMMENTS
M1BA - - - A1 / A-511 A3 / A-511 6" NOMINAL MASONRY
M1BB - 60 MIN U906 A1 / A-511 A3 / A-511 6" NOMINAL MASONRY WITH FLUID APPLIED AIR BARRIER ON CLEANROOM
SIDE (AT CLEANROOM LOCATIONS)
M1BC - 0 HR
SMOKE
- A1 / A-511 A3 / A-511 6" NOMINAL MASONRY
TYPE STC
FIRE
RATING
UL DESIGN
NO
HEAD
DETAIL
BASE
DETAIL TYPE COMMENTS
S3AA STC-45 - - E5 / A-511 C5 / A-511 3 5/8" METAL STUDS WITH BLANKET INSULATION WITH FLUID APPLIED AIR
BARRIER CLEANROOM SIDE.
S3AC STC-45 - - E5 / A-511 C5 / A-511 3 5/8" METAL STUDS WITH BLANKET INSULATION.
S3AD STC-45 - - A5 / A-511 C5 / A-511 3 5/8" METAL STUDS WITH BLANKET INSULATION.
TYPE STC
FIRE
RATING
UL DESIGN
NO
HEAD
DETAIL
BASE
DETAIL TYPE COMMENTS
F1CA - - - E1 / A-511 C1 / A-511 2 1/2" FURRING STUDS AT 16" O.C. VERTICALLY
F1CB - - - A8 / A-511 C1 / A-511 2 1/2" FURRING STUDS AT 16" O.C. VERTICALLY. STOPS 4" ABOVE FINISHED
CEILING.
TYPE
HEAD
DETAIL BASE DETAIL TYPE COMMENTS
CRPS-1 F1 / A-515 A1 & C8 / A-515 3" CLEANROOM PARTITION SYSTEM
CRPS-2 C5 / A-516 C5 / A-516 1/4" ALUMINUM CLEANROOM PARTITION SYSTEM FURRING WALL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
M A
Y
IN
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
J U
L
7/28/21
W
2Q R
R
-0 amartinezrenteria Snapshot
UNDERSIDE OF FLOOR
DECK (CONC. SLAB)
FILL PAN DECK RECESSES
W/ INSULATION
RUNNER TRACK
SLIP CLIP
DEEP LEG RUNNER
(3" LEG MIN.),
ANCHOR TO METAL DECK
M
IN
5/8" TYPE X, MOISTURE
RESISTANT GYPSUM BOARD
ON METAL STUDS @ 16" O.C.,
NUMBER OF LAYERS AND
ORIENTATION VARIES WITH
PARTITION TYPE. SEE FLOOR
PLANS FOR PARTITION TYPE.
BOTTOM OF PAN JOIST
(VARIES)
FILL PAN DECK RECESS W/
FIRE SAFING INSULATION
EXTEND GYPSUM BOARD
INTO METAL DECK FLUTES
UNDERSIDE OF FLOOR
DECK (CONC. SLAB)
5/8" GYPSUM BOARD
ANCHOR TO METAL DEEP
LEG RUNNER. DO NOT
ATTACH TO WALL STUD
5/8" TYPE X, MOISTURE
RESISTANT GYPSUM BOARD
TO METAL WALL STUD UP TO
1" FROM DEEP LEG RUNNER
DEEP LEG RUNNER (3" LEG MIN.),
ANCHOR TO CONCRETE
RUNNER TRACK
SLIP CLIP
UL SYSTEM NUMBER: HW-D-0042
HW-D-0044
M
IN
M
IN 1
M
IN
PROVIDE ACOUSTICAL AND
SMOKESTOP SEALANT AT SMOKE
PARTITIONS AND FIRESTOP
SEALANT AT FIRE RATED
PARTITIONS. TYPICAL EACH SIDE.
BOTTOM OF PAN
JOIST (VARIES)
UNDERSIDE
CONCRETE SLAB
FIRE SAFING
INSULATION
CMU WALL
RE: FLOOR PLANS
FOR TYPE
CONTINUOUS
GALVANIZED STEEL,
BENT PLATE OR
ANGLE - ANCHOR TO
FLOOR DECK ONLYCMU BOND BEAM
MORTAR DAM
UL SYSTEM NUMBER: HW-D-0098, HW-D-0110
M
IN
3"3"
ACOUSTIC OR FIRE SEALANT ON EACH SIDE
FLUID APPLIED AIR BARRIER AT
CLEANROOM SIDE OF WALL
WHERE APPLICABLE. SEAL AIR-
TIGHT AROUND ALL
PENETRATIONS AND AT ALL
ADJACENT CONSTRUCTION
INCLUDING WALLS, FLOOR AND
STRUCTURE (EPOXY PAINT
FINISH WHERE EXPOSED TO
VIEW-EITHER OR BOTH SIDES).
FILL PAN DECK RECESS W/ FIRE SAFING INSULATION
EXTEND GYPSUM BOARD
INTO METAL DECK FLUTES
UNDERSIDE OF FLOOR
DECK (CONC. SLAB)
5/8" GYPSUM BOARD ANCHOR
TO METAL DEEP LEG RUNNER.
DO NOT ATTACH TO WALL STUD
5/8" TYPE X, MOISTURE RESISTANT
GYPSUM BOARD ANCHOR TO
METAL WALL STUD UP TO 1" FROM
DEEP LEG RUNNER
DEEP LEG RUNNER (3" LEG MIN.),
ANCHOR TO DECK
RUNNER TRACK
SLIP CLIP
UL SYSTEM NUMBER: HW-D-0042
HW-D-0044
M
IN
M
IN
M
IN
PROVIDE ACOUSTICAL AND
SMOKESTOP SEALANT AT SMOKE
PARTITIONS AND FIRESTOP
SEALANT AT FIRE RATED
PARTITIONS. TYPICAL EACH SIDE.
FLUID APPLIED AIR BARRIER AT CLEANROOM
SIDE OF WALL WHERE APPLICABLE. SEAL
AIR-TIGHT AROUND ALL PENETRATIONS AND
AT ALL ADJACENT CONSTRUCTION
INCLUDING WALLS, FLOOR AND STRUCTURE.
(PAINT FINISH WHERE EXPOSED TO VIEW.)
USE SELF-ADHERING
AIR BARRIER AT
TRANSITIONS AND
SLIP JOINTS. TYP
CLEANROOM SIDE
CMU WALL
RE: FLOOR
PLANS FOR TYPE
SCHEDULED BASE
RE: ROOM FINISH
SCHEDULE
FINISH FLOOR
RE: ROOM FINISH
SCHEDULE
FLOOR SLAB
FLUID APPLIED AIR BARRIER
AT CLEANROOM SIDE OF
WALL WHERE APPLICABLE.
SEAL AIR-TIGHT AROUND ALL
PENETRATIONS AND AT ALL
ADJACENT CONSTRUCTION
INCLUDING WALLS, FLOOR
AND STRUCTURE (EPOXY
PAINT FINISH WHERE
EXPOSED TO VIEW-EITHER OR
BOTH SIDES).
SCHEDULED BASE
RE: ROOM FINISH
SCHEDULE
5/8" TYPE X, MOISTURE
RESISTANT GYPSUM
BOARD ON METAL STUDS
OR METAL FURRING, SEE
FLOOR PLANS FOR
PARTITION TYPE
FINISH FLOOR
RE: ROOM FINISH
SCHEDULE
FLOOR SLAB
EACH LAYER OF GYPSUM
BOARD SET IN CONTINUOUS
BEAD OF SEALANT (TYP.)
METAL BOTTOM RUNNER
SET IN CONTINUOUS
SEALANT. ATTACH TO SLAB
WITH 1 1/4" HEX HEAD
CONCRETE SCREWS AT 24"
O.C. USE NON-DESTRUCTIVE
MEANS TO VERIFY AND
AVOID DAMAGE TO EXISTING
REINFORCING STEEL.
SCHEDULED BASE
RE: ROOM FINISH
SCHEDULE
5/8" MOISTURE
RESISTANT GYPSUM
BOARD ON METAL
STUDS @ 16" O.C., SEE
FLOOR PLANS FOR
PARTITION TYPE
FINISH FLOOR
RE: ROOM FINISH
SCHEDULE
FLOOR SLAB
EACH LAYER OF GYPSUM
BOARD SET IN CONTINUOUS
BEAD OF SEALANT (TYP.)
5/8" MOISTURE RESISTANT
GYPSUM BOARD ON METAL
STUDS, SEE FLOOR PLANS
FOR PARTITION TYPE
METAL BOTTOM RUNNER SET IN
CONTINUOUS SEALANT. ATTACH
TO SLAB WITH 1 1/4" HEX HEAD
CONCRETE SCREWS AT 24" O.C.
USE NON-DESTRUCTIVE MEANS
TO VERIFY AND AVOID DAMAGE
TO EXISTING REINFORCING STEEL.
SCHEDULED BASE
RE: ROOM FINISH
SCHEDULE
FINISH FLOOR
RE: ROOM FINISH
SCHEDULE
FLOOR SLAB
EACH LAYER OF GYPSUM
BOARD SET IN CONTINUOUS
BEAD OF SEALANT (TYP.)
METAL BOTTOM RUNNER SET IN
CONTINUOUS SEALANT. ATTACH
TO SLAB WITH 1 1/4" HEX HEAD
CONCRETE SCREWS AT 24" O.C.
USE NON-DESTRUCTIVE MEANS
TO VERIFY AND AVOID DAMAGE
TO EXISTING REINFORCING STEEL.
5/8" MOISTURE RESISTANT
GYPSUM BOARD ON METAL
STUDS @ 16" O.C., SEE
FLOOR PLANS FOR
PARTITION TYPE
5/8" MOISTURE RESISTANT
GYPSUM BOARD ON METAL
STUDS, SEE FLOOR PLANS
FOR PARTITION TYPE
FLUID AIR BARRIER AT
CLEANROOM SIDE OF WALL
WHERE APPLICABLE. SEAL
AIR-TIGHT AROUND ALL
PENETRATIONS AND AT ALL
ADJACENT CONSTRUCTION
INCLUDING WALLS, FLOOR
AND STRUCTURE. (PAINT
FINISH WHERE EXPOSED TO
VIEW.)
SCHEDULED
CEILING
5/8" TYPE X, MOISTURE RESISTANT
GYPSUM BOARD ON METAL FURRING,
NUMBER OF LAYERS AND ORIENTATION
VARIES WITH PARTITION TYPE. SEE
FLOOR PLANS FOR PARTITION TYPE.
UNDERSIDE FLOOR DECK
(CONC. SLAB)
C STUD TOP TRACK
SCHEDULED
CEILING
5/8" TYPE X, MOISTURE RESISTANT
GYPSUM BOARD ON METALSTUD, NUMBER
OF LAYERS AND ORIENTATION VARIES
WITH PARTITION TYPE. SEE FLOOR PLANS
FOR PARTITION TYPE.
SCHEDULED
CEILING
BENT METAL TOP CLOSURE FASTENED TO TOP
TRACK. ENSURE FASTENERS, SURFACES, AND
EDGES ARE SMOOTH AND FREE FROM ANY
SHARP PROJECTIONS OR BURRS
CMU WALL
RE: FLOOR PLANS
FOR TYPE
L5x3x1/4 LLV x OPENING
WIDTH + 1'-4" EACH
SIDE W/ 8" MIN.
BEARING AT JAMBS
EXISTING CMU WALL
PL1/4 x 5" x OPENING WIDTH
3/16 2@12
3/16 2@12
3/16 2@12
3/16 2@12
3/4" THROUGH BOLTS
@ 8" OC
LINTEL CONSTRUCTION SEQUENCING NOTES:
1. USE NON-DESTRUCTIVE MEANS TO LOCATE AND AVOID DAMAGING REINFORCING STEEL IN EXISTING MASONRY
2. ROUT OUT MORTAR JOINT ON ONE SIDE OF WALL TO HALF WALL THICKNESS AND INSERT FIRST ANGLE AS INDICATED.
3. ROUT OUT MORTAR JOINT ON OTHER SIDE OF WALL AND INSERT SECOND ANGLE AS INDICATED.
4. DRILL HOLES THROUGH EXISTING CMU AND INSERT THROUGH BOLTS TO CONNECT ANGLES SNUG TIGHT AS INDICATED
5. SAWCUT CMU AT JAMBS AND SILL OF OPENING AND REMOVE CMU.
6. ATTACH CLOSURE PLATE AS INDICATED.
CMU WALL
RE: FLOOR PLANS FOR TYPE
CMU LINTEL W/ (2) #5 BARS.
GROUT SOLID
VERTICAL REINF
GROUT SOLID
LINTEL L-1 LINTEL L-2
TYP FOR CMU OPNGS UP TO
4'-0" WIDE. PROVIDE 8" MIN
BEARING AT JAMBS
TYP FOR CMU OPNGS 4'-0" TO
10'-0" WIDE. PROVIDE 16" MIN
BEARING AT JAMBS
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
P N
SHEET ID
C E
R T
IF
IE
D F
IN
A
L
2 864 10
E
F
G
A-511
C B
A R
D
N C
O H
E N
A M
A R
T
IN
E Z
/2
/2
Z H
T V
W P
A F
B X
T A
L
Z H
T V
W P
A F
B X
T A
L R
E N
O V
A T
IO
N
P A
R T
IT
IO
N T
Y P
E D
E T
A
IL
S
W R
IG
H
T -P
A T
T E
R S
O N
A F
B
O H
SCALE: 3" = 1'-0"E1
PARTITION DETAILS
SCALE: 3" = 1'-0"E3
PARTITION DETAILS
SCALE: 3" = 1'-0"A1
PARTITION DETAILS
SCALE: 3" = 1'-0"E5
PARTITION DETAILS
SCALE: 3" = 1'-0"A3
PARTITION DETAILS
SCALE: 3" = 1'-0"C1
PARTITION DETAILS
SCALE: 3" = 1'-0"C3
PARTITION DETAILS
SCALE: 3" = 1'-0"C5
PARTITION DETAILS
SCALE: 3" = 1'-0"A5
PARTITION DETAILS
SCALE: 3" = 1'-0"A8
PARTITION DETAILS
SCALE: 3" = 1'-0"E8
PARTITION DETAILS
SCALE: 3" = 1'-0"C8
PARTITION DETAILS
SCALE IN FEET
0 3" 6" 9"
SCALE IN FEET
0 3" 6" 9"
SCALE IN FEET
0 3" 6" 9"
SCALE IN FEET
0 3" 6" 9"
SCALE IN FEET
0 3" 6" 9"
SCALE IN FEET
0 3" 6" 9"
SCALE IN FEET
0 3" 6" 9"
SCALE IN FEET
0 3" 6" 9"
SCALE IN FEET
0 3" 6" 9"
SCALE IN FEET
0 3" 6" 9"
SCALE IN FEET
0 3" 6" 9"
SCALE IN FEET
0 3" 6" 9"
BLUNT CORNERS OF
CMU TO ACCOUNT FOR
SHAPE OF STEEL ANGLE
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
M A
Y
IN
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
J U
L
7/28/21
W
2Q R
R
-0 amartinezrenteria Snapshot
GENERAL ROOM FINISH SCHEDULE NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
REFER TO SPECIFICATIONS FOR THE BASIS OF DESIGN OR
EQUIVALENT MANUFACTURER TECHNICAL REQUIREMENTS.
REFER TO INTERIOR ELEVATIONS, REFLECTED
CEILING DRAWINGS, FLOOR FINISH DRAWINGS, WALL FINISH
DRAWINGS, ENLARGED PLAN DRAWINGS AND INTERIOR DETAIL
DRAWINGS FOR ADDITIONAL FINISH PLACEMENT INFORMATION.
REFER TO ELECTRICAL DRAWINGS, MECHANICAL DRAWINGS,
STRUCTURAL DRAWINGS AND COMMUNICATION DRAWINGS
FOR COORDINATION OF BUILDING FINISHES TO BUILDING
SYSTEMS.
REFER TO FLOOR FINISH DRAWINGS FOR PLACEMENT OF
FLOOR FINISHES, FLOOR PATTERNS AND FLOOR MATERIAL
CHANGES. REFER TO FLOORING TRANSITION DETAILS FOR
TRANSITIONS BETWEEN ADJOINING FLOORING MATERIALS.
REFER TO WALL FINISH DRAWINGS AND INTERIOR ELEVATIONS
FOR WALL FINISH EXTENTS, CORNER GUARD LOCATIONS,
SIGNAGE, ART AND SPECIALTY WALL FINISH LOCATIONS.
REFER TO REFLECTED CEILING DRAWINGS FOR CEILING
HEIGHTS AND CEILING MATERIAL EXTENTS.
PROVIDE BLOCKING AS REQUIRED TO SECURE ALL WALL
MOUNTED ITEMS INCLUDING TOILET FIXTURES, TOILET
ACCESSORIES, TOILET PARTITIONS, MILLWORK, SHELVES,
COUNTERTOP SUPPORTS, MARKERBOARDS, TACKBOARDS,
FLAT PANEL DISPLAYS, CAMERAS, ACOUSTICAL WALL PANELS,
MURAL OR ART CABLE SYSTEMS, AND ANY OTHER WALL
MOUNTED OBJECT.
UNLESS NOTED OTHERWISE, ALL EXPOSED STRUCTURAL
STEEL TO BE PAINTED PA-1.
ALL DOOR AND FRAMES TO BE PAINTED IN ACCORDANCE WITH THE
DOOR SCHEDULE .
ALL METAL FABRICATIONS TO BE PA-2.
INTERIOR CAULKING TO MATCH ADJACENT WALL FINISH COLOR.
ALL EXPOSED CONCRETE FLOORS SHALL BE SEALED WITH LIQUID
CHEMICAL SEALERS. USE CONCRETE PENETRATING SEALERS WITH A
LOW VOC CONTENT. SUBMIT MANUFACTURER'S INSTRUCTIONS FOR
PLACEMENT OF SEALERS. ALL EXPOSED CONCRETE FLOOR
SURFACES NOT IDENTIFIED IN ROOM FINISH SCHEDULE SHALL BE
SEALED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
WALL CORNER GUARDS TO BE INSTALLED STARTING AT THE
TOP OF THE SCHEDULED WALL BASE.
AT GYPSUM BOARD SOFFITS AND BULKHEADS, PAINT ALL
EXPOSED SURFACES.
PAINT ALL EXPOSED STRUCTURAL STEEL ELEMENTS,
MISCELLANEOUS STEEL, PIPING, HANGERS, VALVES AND
CONDUITS. THE PAINT COLOR SHALL BE AS INDICATED
ON SCHEDULE. ALL FIRE PROTECTION PIPING COLOR SHALL
BE SAFETY RED.
ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND
ASSOCIATED SUPPORTING EQUIPMENT TO BE PAINTED
PA-1 UNLESS OTHERWISE REQUIRED BY CODE.
COORDINATE WITH MECHANICAL / ELECTRICAL FOR FINISHES
ON MECHANICAL OR ELECTRICAL EQUIPMENT.
DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL
SURFACES, OPERATING PARTS, LABELS OR WARNINGS.
REFER TO AND COORDINATE WITH FURNITURE DRAWINGS
AND TYPICAL MOUNTING HEIGHTS DRAWING FOR WALL
MOUNTING HEIGHTS OF FF&E.
REFER TO FINISH SCHEDULE COLOR SCHEDULE FOR INTERIOR FINISH
MATERIALS. BASIS OF DESIGN OR EQUIVALENT COLOR AND FINISH
CODES ARE AS INDICATED ON THE ROOM FINISH SCHEDULE.
GENERAL SIGNAGE SCHEDULE NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
REFER TO SIGNAGE PLACEMENT DRAWINGS FOR LOCATION
OF INTERIOR SIGNS.
REFER TO SIGNAGE DETAILS FOR SIGNAGE CONSTRUCTION
AND MOUNTING ELEVATION.
REFER TO ARCHITECTURAL DRAWINGS FOR COORDINATION
OF SIGNAGE INSTALLATION TO WALL CONSTRUCTION.
SIGNAGE MUST BE ANCHORED THRU THE SURFACE APPLIED
WALL FINISHES TO THE SUBSTRATE WALL.
ALL HARDWARE/MOUNTING ATTACHMENTS TO BE CONCEALED
AND APPROPRIATE FOR THE RECEIVING BUILDING SURFACE.
ALL SIGNAGE SHALL COMPLY WITH THE MOST CURRENT
VERSION OF THE ARCHITECTURAL BARRIERS ACT ACCESSIBILITY
STANDARDS (ABAAS).
ALL SIGNAGE MOUNTED ON GLASS SHALL HAVE A MATCHING
BACK PLATE TO CONCEAL ATTACHMENT METHOD OF SIGN.
INSTALL FIRE EXTINGUISHER IDENTIFICATION SIGN ABOVE ALL
FIRE EXTINGUISHER CABINETS AND WALL BRACKET MOUNTED
EXTINGUISHERS. SEE LIFE SAFETY PLANS FOR FIRE
EXTINGUISHER LOCATIONS.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING WITH SIGNAGE MANUFACTURER(S) TO
PROVIDE ANY ADDITIONAL SIGNAGE AS REQUIRED BY
GOVERNING MUNICIPALITY AT THE SITE LOCATION.
ALL MESSAGE TEXT AS SHOWN ON THE SIGN SCHEDULE IS A
PLACE HOLDER ONLY AND IS NOT THE FINAL TEXT MESSAGE.
ALL MESSAGE TEXT SHALL BE CONFIRMED BY GOVERNMENT
END USER PRIOR TO SIGNAGE SHOP DRAWINGS. ALLOW FOR
MAXIMUM 4 DIGIT ROOM NUMBERS AND MINIMUM 25
CHARACTER ROOM NAMES TYPICAL FOR ALL SIGNS.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
OBTAINING LOGO IMAGES FROM APPROVED GOVERNMENT
REPRESENTATIVE AND PROVIDING TO SIGNAGE
MANUFACTURER(S). SIGNAGE MANUFACTURER(S) SHALL BE
RESPONSIBLE FOR CREATING VECTOR IMAGES FOR
INCORPORATION INTO SIGNAGE BACKGROUND INSERTS AND
LOGO MEDALLION SIGNAGE.
PROVIDE MESSAGE INSERTS FOR WINDOW SIGNS WHERE
INDICATED IN THE SIGNAGE DRAWINGS OR SPECIFICATIONS.
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
P N
SHEET ID
C E
R T
IF
IE
D F
IN
A
L
2 864 10
E
F
G
/8
A-701
S B
G A
S B
/2
/2
Z H
T V
W P
A F
B X
T A
L
Z H
T V
W P
A F
B X
T A
L R
E N
O V
A T
IO
N
R O
O M
F
IN
IS
H
S C
H E
D U
L E
F
IN
IS
H L
E G
E N
D
A N
D S
IG
N
A G
E S
C H
E D
U L E
W R
IG
H
T -P
A T
T E
R S
O N
A F
B
O H
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR
BASE WALLS
CEILING
REMARKSMATERIAL HEIGHT NORTH EAST SOUTH WEST
FIRST FLOOR
118 OFFICE (EXIST) EXISTING RB-1 RB-1 EXISTING EXISTING EXISTING PA-1 EXISTING
119 MECHANICAL ROOM CH-1 - - PA-1 PA-1 PA-1 PA-1 OPEN TO STRUCTURE
121 As MBE LAB RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
121A MBE SUPPORT RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 OPEN TO STRUCTURE
122 NEXT GEN MBE LAB RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
123 STRUCTURAL CHARACTERIZATION RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
124 SURFACE SCIENCE EAST RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
148 GOWNING ROOM SV-1 Integral Base 4" CRPS-1 CRPS-1 CRPS-1 CRPS-1 CRCS-1
148A ANTEROOM SV-1 Integral Base 4" CRPS-1 CRPS-1 CRPS-1 CRPS-1 CRCS-1
148B ETCH & DEP BAY SV-1 Integral Base 4" CRPS-1 / CRPS-2 CRPS-1 CRPS-1 CRPS-1 CRCS-1
148C ETCH & DEP SUPPORT SV-1 Integral Base 4" CRPS-1 CRPS-1 / PE-1 CRPS-1 CRPS-1 OPEN TO STRUCTURE
149 LITHO BAY SV-1 Integral Base 4" CRPS-1 CRPS-1 CRPS-1 CRPS-1 / CRPS-2 CRCS-1
149A LITHO SUPPORT ROOM SV-1 Integral Base 4" CRPS-1 / PE-1 CRPS-1 / PE-1 CRPS-1 / PE-1 CRPS-1 / PE-1 OPEN TO STRUCTURE
150 LITHO PREP BAY SV-1 Integral Base 4" CRPS-1 CRPS-1 CRPS-1 CRPS-1 / CRPS-2 CRCS-1
151 SEM ROOM RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
152 SURFACE SCIENCE WEST RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
152A SURFACE SCIENCE SUPPORT RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
156 EAST CORRIDOR EXISTING EXISTING - PA-1 PA-1 PA-1 PA-1 ACT-1 MATCH SOUTH CORRIDORS
158 WEST CORRIDOR EXISTING EXISTING - PA-1 PA-1 PA-1 PA-1 ACT-1 MATCH SOUTH CORRIDORS
160 VESTIBULE WOM-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1 MATCH SOUTH CORRIDORS / ALUMINUM STOREFRONT
UC09 UTILITY CORE (EXIST) - - - - - - - OPEN TO STRUCTURE
UC10 UTILITY CORE (EXIST) - - - - - - - OPEN TO STRUCTURE
UC11 UTILITY CORE (EXIST) - - - - - - - OPEN TO STRUCTURE
FINISH LEGEND - BASIS OF DESIGN OR EQUIVALENT
MATERIAL DESCRIPTION MANUF. MODEL NUMBER PRODUCT NUMBER COLOR REMARKS
CEILINGS
ACT-1 24" x 24" / CLEANROOM / 15/16" CLEANROOM GRID ARMSTRONG CLEAN ROOM FL 1715 WHITE WITH GRAY SPATTER (WG) NON-SHEDDING
CRCS-1 CLEANROOM CEILING SYSTEM PORTAFAB 2" GASKETED CEILING GRID WITH FFU'S FFU'S & BLANKING PANELS OR CLEANROOM ACOUSTIC TILE - ISO 6
CRCS-2 CLEANROOM CEILING SYSTEM PORTAFAB 2" GASKETED CEILING GRID WITH FFU'S FFU'S & ANODIZED ALUMINUM BLANK-OFF PANELS - ISO 5
FLOORING
CH-1 CONCRETE SEALER PROSOCO CONSOLIDECK LS/CS - - SEE NOTE 12
RF-1 12" X 12" RESILIENT TILE (VCT) ARMSTRONG - 51904 STERLING
SV-1 PVC-FREE HOMOGENEOUS SHEET FLOORING ARMSTRONG MEDINPURE WITH DIAMOND 10 TECHNOLOGY H6004 MIRROR LAKE
WOM-1 24" X 24" WALK OFF MAT SHAW CONTRACT PORTAL TILE 5T035 MULTICOLOR 34481
MISCELLANEOUS
CG-1 CORNER GUARD KOROSEAL - GS15 STAINLESS STEEL
RB-1 RUBBER BASE ROPPE PINNACLE/TS/1/8" 100 BLACK 4"
WALLS
CRPS-1 CLEANROOM PARTITION SYSTEM PORTAFAB S3000 - CLEAR ANODIZED ALUMINUM
CRPS-2 CLEANROOM PARTITION SYSTEM PORTAFAB FABLINE FURRING 250 - CLEAR ANODIZED ALUMINUM
PA-1 ACRYLIC/LATEX SHERWIN WILLIAMS - SW7070 SITE WHITE FIELD PAINT
PA-2 ACRYLIC/LATEX SHERWIN WILLIAMS - SW6228 REFUGE BLUE DOORS AND FRAMES
PA-3 ACRYLIC/LATEX SHERWIN WILLIAMS - SW7007 CEILING BRIGHT WHITE HARD CEILING/BULKHEADS
PE-1 EPOXY SHERWIN WILLIAMS - SW7070 SITE WHITE RETURN AIR CHASES
PE-2 EPOXY SHERWIN WILLIAMS INDUSTRIAL PRO INDUSTRIAL PRE-CATALYZED
WATERBASED EPOXY
COLOR MATCH SW6228 REFUGE BLUE STEEL DOORS AND FRAMES
SIGNAGE SCHEDULE
TAG SIGN TYPE SIGN NUMBER MESSAGE TEXT REMARKS
S101 B 119 MECHANICAL ROOM
S102 A 121 III/V MBE LAB
S103 B 121A UTILITY
S104 A 122 OXIDE MBE LAB
S105 A 123 STRUCTURAL CHARACTERIZATION
S106 A 124 SURFACE SCIENCE
S107 B 152A UTILITY
S108 B 152A UTILITY
S109 A 152 SURFACE SCIENCE
S110 A 151 SEM LAB
S111 A 150 LITHO PREP BAY
S112 B 149A UTILITY
S113 B 148C UTILITY
S114 A 148 GOWNING
S115 B 119 MECHANICAL ROOM
* REFER TO AFRL / RX STANDARDS FOR FINAL SIGNAGE DESIGN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
M A
Y
IN
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
J U
L
7/28/21
W
2Q R
R
-0 amartinezrenteria Snapshot
F23B-F2 10.25"W X 10.5"H
LUMICOR LARGE OVALESQUE
.25" PATINA 2S
CHEMETAL 450 CYCLONE
BRONZE
CO101 BLACK
FONT HELVETICA BOLD
TYPE 0.2
12"W X 25"H
LUMICOR LARGE OVALESQUE
.25" PATINA 2S
CHEMETAL 450 CYCLONE
BRONZE
MEDIA: WHITE PAPER FONT: HELVETICA BOLD;
COPY COLOR: BLACK
CO101 BLACK
FONT HELVETICA BOLD
CHEMETAL 450 CYCLONE
T O
3"
BASE LINE OF HIGHEST COPY MOUNTED
NO HIGHER THAN 60" AFF
BASELINE OF LOWEST COPY MOUNTED
NO LOWER THAN 48" AFF
MOUNT SIGN ON LATCH SIDE OF DOOR
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
P N
SHEET ID
C E
R T
IF
IE
D F
IN
A
L
2 864 10
E
F
G
A s i n d ic a te d
A-702
S B
G A
S B
/2
/2
Z H
T V
W P
A F
B X
T A
L
Z H
T V
W P
A F
B X
T A
L R
E N
O V
A T
IO
N
S
IG
N A
G E
D E
T A
IL
S
W R
IG
H
T -P
A T
T E
R S
O N
A F
B
O H
SCALE: 1" = 1'-0"A6
SIGN TYPE - B
SCALE: 1" = 1'-0"A4
SIGN TYPE - A
SCALE: 3/4" = 1'-0"A1
TYPICAL INTERIOR SIGN INSTALLATION - WALL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
M A
Y
IN
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
J U
L
7/28/21
W
2Q R
R
-0 amartinezrenteria Snapshot
PROVIDE CEILING MOUNTED SPEAKERS AND
CLEAR STROBES AND AMBER STROBES AS
REQUIRED TO ACHIEVE DESIGN CRITERIA.
NOTIFICATION APPLIANCES ARE NOT REQUIRED
TO BE MODIFIED.
NO HATCH
AREA OUTSIDE OF SCOPE OF WORK.
PROVIDE WALL MOUNTED SPEAKERS AND
CLEAR STROBES AND AMBER STROBES AS
REQUIRED TO ACHEIVE DESIGN CRITERIA.
1 2 3 4 5 6 7 8
A
B
C
D
E
ASD
ACUFACU
NACAMP
S S
MECHANICAL
ROOM
UTILITY CORE
(EXIST)
UC09
UTILITY CORE
(EXIST)
UC10
UTILITY CORE
(EXIST)
UC11
STRUCTURAL
CHARACTERIZATION
As MBE LAB
NEXT GEN MBE
LAB
ETCH & DEP BAY
148B
LITHO BAY
LITHO PREP BAY
LITHO SUPPORT
ROOM
149A
GOWNING ROOM
MBE SUPPORT
121A
SURFACE
SCIENCE EAST
SURFACE
SCIENCE
SUPPORT
152A
ETCH & DEP
SUPPORT
148CANTEROOM
148A
SURFACE
SCIENCE WEST
SEM ROOM
EAST CORRIDOR
VESTIBULE
F C
F C
F
C
5 WF
VS
A
B
C
D
E
1 2 3 4 5 6 7 8
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
A B
KEY PLAN
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
P N
SHEET ID
C E
R T
IF
IE
D F
IN
A
L
2 864 10
E
F
G
N.T.S.
NORTH
A s i n d ic a te d
FA101
M A
L -A
W A
M I
A A
T A
IY
A
N M
M
A F
F E
I
M A
Y
Z H
T V
Z H
T V
W P
A F
B X
T A
L R
E N
O V
A T
IO
N
F
IR
E A
L A
R M
F
IR
S T
F L O
O R
P L A
N
W R
IG
H
T P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E O
H
IO
1. REFER TO FA001 FOR GENERAL NOTES, DESIGN
CRITERIA, ABBREVIATIONS AND SYMBOLS.
1. PROVIDE VEWSD VIA AN AIR SAMPLING SMOKE
DETECTOR ALONG RETURN GRILLES IN THE CLEANROOM
IN ACCORDANCE WITH NFPA 318 11.1.3.1. REFER TO
A1/FA601 FOR DESIGN CRITERIA.
2. IF REQUIRED BY CONTRACTORS DESIGN TO SATISFY THE
DESIGN CRITERIA, PROVIDE ADDITIONAL AMP AND NAC
PANELS IN THIS LOCATION.
3. UPON COMPLETION OF FIRE SPRINKLER SYSTEM
MODIFICATIONS, REMOVE TEMPORARY HEAT
DETECTION. COORDINATE WITH THE FIRE SPRINKLER
CONTRACTOR PRIOR TO REMOVAL OF TEMPORARY HEAT
DETECTION.
4. PROVIDE TAMPER SWITCH FOR NEW ISOLATION VALVE
PROVIDED BY DIV 21.
5. BID OPTION - VEST AND CORE LTG.
NTSSCALE:A1
OVERALL FIRE ALARM PLAN
0 4' 8' 16'
GENERAL SHEET NOTES
SHEET KEYNOTES
LEGEND
NORTH
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
M A
Y
IN
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
J U
L
7/28/2021
B Y
W
2Q R
R
-0
1 2 3 4 5 6 7 8
B
C
D
E
LAB
LAB
LAB
LAB
LAB
LAB
LAB
LAB
LAB
LAB
LAB
UTILITY CORE
UC09
UTILITY CORE
UC10
LAB
147A
LAB
147B
LAB
ACUFACU
NACAMP
UTILITY CORE
UC11
F C
F C
F
C 2
A
B
C
D
E
1 2 3 4 5 6 7 8
DEMOLISH FIRE ALARM NOTIFICATION
APPLIANCES, CONDUCTORS, AND CONDUIT IN
THIS AREA. WHERE EXISTING CIRCUITS SUPPLY
NOTIFICATION APPLIANCES IN OTHER AREAS,
MAINTAIN THE INTEGRITY OF THOSE CIRCUITS
AS NECESSARY TO MAINTAIN NOTIFICATION
COVERAGE OUTSIDE OF THE SCOPE OF WORK
AREA DURING CONSTRUCTION.
AREA OUTSIDE OF FIRE ALARM SCOPE OF
WORK.
MAINTAIN EXISTING NOTIFICATION
DEVICES IN UTILITY CORES. DEMOLITION
NOT REQUIRED.
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
A B
KEY PLAN
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .