This is a solicitation for lab renovations for the XTAL Building 654 at Wright-Patterson Air Force Base in Ohio. The estimated construction cost is between $5 million and $10 million. The work includes renovating approximately 6,300 square feet of existing lab space on the first floor to convert some areas to cleanroom facilities. An organized site visit is scheduled for July 1, 2021 at 9:00 AM Eastern Time and interested parties must RSVP by June 28. The NAICS code is 236220 with a size standard of $39.5 million. This is a full and open procurement that requires a 10% price evaluation for HUBZone small businesses. Responses are due by the date and time specified in the solicitation.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation For XTAL Renovations Project Bldg 654 Wright-Patterson AFB, OH
P2: 487666
Design Bid Build
FF&E
Certified Final Design Submittal
23 June 2021
W912QR21R0051
ARIMS: 200A
Disposition: Maintain for 15yrs after construction
W912QR21R0051-0000
P2#487666 XTAL Renovation Project CERTIFIED FINAL DESIGN SUBMITTAL Wright-Patterson AFB, OH
THIS PAGE INTENTIONALLY LEFT BLANK
XTAL RENOVATION PROJECT
WRIGHT-PATTERSON AFB, OH
RTA DESIGN SUBMITTAL
FURNITURE, FIXTURES, AND EQUIPMENT (FF&E)
MAY 2021
TABLE OF CONTENTS
FFE NARRATIVE & DIVISION 12 SPECIFICATIONS
CODES AND COSTS
POINT OF CONTACT AND MANUFACTURERS LIST
ACCESSORIES
CHAIRS
DESKS
FILES AND STORAGE
TABLES
SECTION 09 EQUIPMENT
SECTION 10 DRAWING
SECTION 11 FINISHES
SECTION 05
SECTION 06
SECTION 07
SECTION 08
SECTION 03
SECTION 02
SECTION 01
SECTION 04
XTAL RENOVATION PROJECT
WRIGHT PATTERSON, AFB, OH MAY 2021
SECTION 01
NARRATIVE
XTAL RENOVATION PROJECT
WRIGHT PATTERSON, AFB, OH
XTAL Renovation Project
Mission Statement:
The Louisville District of the Army Corps of Engineers has engaged Burns & McDonnell to provide design services for the remodeling approximately 6,300 gross square feet (7,810 gross square feet including corridors not enumerated in the DD1391) of existing lab space on the first floor of in building 20654 at Wright-Patterson AFB in Dayton, Ohio. The design should follow the AFRL/RXOE STANDARDS, LOUISVILLE DISTRICT MILITARY GUIDE (LDMDG), and BASE FACILITY STANDARD (BFS) Wright- Patterson AFB.
Scopes of work for this project include:
• Identification and abatement of hazardous materials within designated project area only.
• Demolition of all non-load bearing interior partitions, finishes, materials, back to the existing concrete frame within designated project area only.
• Retain existing roof and roof insulation with modifications, as necessary, to install new ventilation equipment.
• Provide new interior signage within designated project area only.
• Demolish and replace HVAC system within designated project area only.
• Demolish and replace electrical systems, lighting, and data cabling within designated project area only.
• Tie-into existing fire alarm and fire suppression systems within designated project area only.
General Facility Description:
The design will renovate approximately 6,300 square feet of existing laboratory space on the first floor of Building 654. Approximately 3,225 square feet of the renovated space will be conventional laboratory space for epitaxial growth materials and characterization labs. Approximately 1,955 square feet will be converted to cleanroom facilities (class 100 and class 1000 (or ISO 5 and 6)) spaces. The balance of the renovated space will be for mechanical and process support equipment for the laboratories and cleanrooms. The ground floor mechanical and electrical rooms may be utilized if additional space is needed for new support equipment (if there is sufficient space available). A new stand-by generator will be provided to supply stand-by power to the EPI Growth laboratory process equipment to allow for proper equipment shutdown during a power outage.
Applicable Design Manuals, Codes, Criteria:
• IBC international building code 2015
• NFPA 01 Uniform Fire Code 2018
• NFPA 13 Standard for The Installation of Sprinkler Systems 2016
• NFPA 70 National Electrical Code 2017
• NFPA 72 National Fire Alarm and Signaling Code 2016
• NFPA 80 Standard for Fire Doors and Other Opening Protectives 2016
• NFPA 90a Standard for The Installation of Air-Conditioning and Ventilating Systems 2015
• NFPA 101 Life Safety Code 2018
• NFPA 400 Hazardous Materials Code 2016
• UFC 1-200-01 DOD Building Code General Building Requirements Feb 2018
• UFC 3-230-01 Water Storage, Distribution, And Transmission July 2014
• UFC 3-600-01 Design: Fire Protective Engineering for Facilities Mar 2018
• UFC 4-010-01 DOD Minimum Antiterrorism Standards for Buildings Oct 2013
• UFC 4-021-01 Design And O&M: Mass Notification Systems Jan 2010
• AR 380-05 Department of The Army Information Security Program 2000
• AR 405-70 Utilization of Real Property 2006
• AR 420-01 Army Facilities Management 2007
XTAL RENOVATION PROJECT
WRIGHT PATTERSON, AFB, OH
• DA PAM 415-28 construction real property category codes apr 2014
Design Intention:
The FF&E will reflect the aesthetically pleasing surroundings through the harmonization of the materials, finishes and color palette. The facility shall be attractive and safe, provide materials that are low maintenance, durable, and timeless in style, while responsive to the end users’ needs and function. The interiors will promote an appropriate professional image for the administrative and learning environment and still be receptive to the working environment which maximizes the units’ mission.
Furnishings Analysis:
The criteria for the FF&E benefits both the facility needs, and user needs from a facility management and health prospective. The facility requires furnishings that respond to the demanding physical requirements of the constant utilization within this high-use facility environment. Of equal importance to the function of the furnishings is to provide proper ergonomic support which plays a key role in the satisfaction, well-being, and productivity of the personnel when furnishings are properly sized.
Users and missions on DoD installations change over time. This creates a need for Furniture, Fixtures and Equipment to be adaptable to respond to changing needs by being modular and flexible so that modifications can be made with minimal impact to the end user on site.
Furnishings that can be modified and repaired by on-site personnel with limited or no tools will be taken into consideration. Due to the secured environment, this quality is of critical value to the end user and will be taken into consideration during furniture evaluation analysis.
All furnishings shall be analyzed with consideration based on cost, functional solution, ergonomic solution, sustainability, and technical and user requirements.
Sustainability:
Furnishings shall be selected from manufacturers that utilize green manufacturing processes, and produce products that are Green Guard Certified, with recycled content materials. When possible, furnishings shall be provided that achieve the “Cradle to Cradle” environmental status to reduce future landfill use.
Furnishings shall be selected from manufacturers that utilize the following criteria:
• ANSI/BIFMA e3 Furniture Sustainability Standard or 3rd party certified to meet the same standards criteria.
• GREENGUARD or Scientific Certification Systems (SCS) Certified or industry-independent, third-party testing and indoor air quality certification and demonstrates compliance to
ANSI/BIFMA criteria for low-emitting furniture.
• Scientific Certification Systems (SCS) Certified
• Cradle to Cradle Certified (c2c)
XTAL RENOVATION PROJECT
WRIGHT PATTERSON, AFB, OH
Styles and Types – FF&E:
The furniture style for the building will be transitional style with clean design lines and simple forms that function efficiently. The criterion for the interior furnishings (FFE) included providing product types and layouts that are designed to work with the equipment required in each lab. The furnishings are value oriented with ergonomic, compatibility with lab equipment, and finishes proven for longevity and chemical resistance.
Interior Furnishings Standards – FF&E:
The furnishings must be durable, easy to reconfigure, have a limited kit of parts to manage, and easily responds to change. The furnishings must support the users work and health with balanced lighting, ergonomic support, and environmentally sensitive materials for a non-toxic, productive environment.
Of equal importance to the function of the furnishings, ergonomic support and features that encourage a healthy work environment to the users are critical. The furnishings size and adjustability features will accommodate a minimum of 95% of the facility population size. Other healthy / ergonomic furniture features include:
• Seating for all users with easily adjustable mechanism for height, arms, and back, breathable fabric for comfort, and seat pan front edges that will not cut off circulation while sitting.
• Selecting furnishings from manufacturers that utilize green manufacturing processes, and produce products that are Green Guard Certified, with recycled content materials. When possible, furnishings will be provided that achieve the “Cradle to Cradle” environmental status to reduce future landfill use.
Furnishings to be provided include, freestanding desking, freestanding bench configuration, task seating, storage and chemical storage, waste receptacles, and PPE dispensers.
P2#487666 XTAL Renovation Project CORRECTED FINAL DESIGN SUBMITTAL
SECTION 12 31 00
MANUFACTURED METAL CASEWORK
11/14
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN WELDING SOCIETY (AWS)
AWS D1.1/D1.1M (2020) Structural Welding Code - Steel
AWS D1.3/D1.3M (2018) Structural Welding Code - Sheet Steel
ASTM INTERNATIONAL (ASTM)
ASTM A325 (2014) Standard Specification for Structural Bolts, Steel, Heat Treated, 120/105 ksi Minimum Tensile Strength
ASTM A325M (2014) Standard Specification for Structural Bolts, Steel, Heat Treated, 830 MPa Minimum Tensile Strength (Metric)
ASTM A1008/A1008M ( 2018 2020 ) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable
ASTM F594 (2009; R 2020) Standard Specification for Stainless Steel Nuts
ASTM F836M (2016, E 2018) Standard Specification for Style 1 Stainless Steel Metric Nuts (Metric)
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.9 (2015) Cabinet Hardware
KITCHEN CABINET MANUFACTURERS ASSOCIATION (KCMA)
KCMA A161.1 (2017) Performance & Construction Standards for Kitchen and Vanity Cabinets
U.S. GENERAL SERVICES ADMINISTRATION (GSA)
FS FF-B-588 (Rev E; Notice 1) Bolt, Toggle: and Expansion Sleeve, Screw
SECTION 12 31 00 Page 1
FS FF-S-325 (Basic; Int Amd 3; Notices 3, 4) Shield, Expansion; Nail, Expansion; and Nail, Drive Screw (Devices, Anchoring, Masonry)
FS TT-E-489 (Rev J; Notice 2) Enamel, Alkyd, Glass, Low VOC Content
FS TT-F-336 (Rev E; Notice 1) Filler, Wood, Paste
1.2 ADMINISTRATIVE REQUIREMENTS
1.2.1 Pre-Installation Meeting
Within [ 30] [_____] calendar days after [ date of award ] [date of receipt by him of notice of award] , submit for the approval of the Contracting Officer [ six (6) ] [_____] copies of outline drawings of all casework to be furnished under this contract, together with weights and overall dimensions, and required samples. Ensure drawings show the general arrangement and overall dimensions of the casework, details of any casework supports [ . ][, and provisions for electrical outlets.][, special provisions for external cables and cords.] Submit the following for review and approval:
a. Fabrication Drawings.
b. Installation Drawings.
Submit installation drawings for metal cabinets. Include in drawings the location of cabinets, details of cabinet relationship and dimensional positions, and locations for roughing in plumbing, including sinks, faucets, strainers and cocks [, special electrical lines or conduits] [cables] [_____] .
Submit manufacturer's catalog data and certificates for the following items showing conformance with the referenced standards contained in this section:
a. Cabinets.
b. Corrosion-Resistant Steel.
[ c. Glass.
] dc. Adhesives.
ed. Filler Material.
f e. Fasteners.
[ g. Steel Sinks.
][ hf . Service Fixtures.
] i g. Accessories and Hardware.
j. Plastic Laminate.
kh. Countertops.
SECTION 12 31 00 Page 2
Submit manufacturer's instructions for metal cabinet systems including special provisions required to install equipment components and system packages. Include special notices detailing impedances, hazards and safety precautions.
Submit manufacturer's standard color charts for metal cabinets showing the manufacturer's recommended color and finish selections.
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are [for Contractor Quality Control approval.][ for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. ] Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 .00 06 SUSTAINABILITY REPORTING. Submit the following in accordance with Section
01 33 00 .00 06 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Fabrication Drawings [ ; G AE RO [, [____]] ]
Installation Drawings [ ; G AE RO [, [____]] ]
SD-03 Product Data
Cabinets [ ; G AE RO [, [____]] ]
Corrosion-Resistant Steel [ ; G AE RO [, [____]] ]
[ Glass[; G [, [____]] ] ]
Adhesives [ ; G AE RO [, [____]] ]
Filler Material [ ; G AE RO [, [____]] ]
Fasteners [ ; G AE RO [, [____]] ]
[ Steel Sinks[; G [, [____]] ] ]
[ Service Fixtures[; G [, [____]] ] ]
Accessories and Hardware [ ; G AE RO [, [____]] ]
Plastic Laminate[; G [, [____]] ]
Countertops [ ; G AE RO [, [____]] ]
SD-04 Samples
Accessories and Hardware [ ; G AE RO [, [____]] ][; G][; G, [_____]]
Manufacturer's Standard Color Charts [ ; G AE RO [, [____]] ]
SD-07 Certificates
Corrosion-Resistant Steel [ ; G AE RO [, [____]] ]
SECTION 12 31 00 Page 3
Glass [ ; G AE RO [, [____]] ]
Adhesives [ ; G AE RO [, [____]] ]
Filler Material [ ; G AE RO [, [____]] ]
Fasteners [ ; G AE RO [, [____]] ]
Steel Sinks[; G [, [____]] ]
Service Fixtures[; G [, [____]] ]
Accessories and Hardware [ ; G AE RO [, [____]] ]
SD-08 Manufacturer's Instructions
Manufacturer's Instructions [ ; G AE RO [, [____]] ]
1.4 DELIVERY, STORAGE, AND HANDLING
Deliver, store, and handle metal casework in a manner that prevents damage or disfigurement.
Provide temporary skids under units weighing more than [_____] pounds.
PART 2 PRODUCTS
2.1 SYSTEM DESCRIPTION
2.1.1 Design Requirements
Provide metal casework, factory-fabricated and finished in the manufacturer's standard sizes and finishes of the type, design, and configuration indicated. Construct casework as specified and meet the requirements of KCMA A161.1 . Provide wall and base cabinet assemblies consisting of individual units joined into continuous sections.
Accomplish fastenings to permit removal and replacement of individual units without affecting the remainder of the installation. Provide counters with watertight sink rim when indicated. Provide removable doors equipped with position stops to avoid accidental complete withdrawals.
Fix or adjust shelves as indicated.
2.2 MATERIALS
Provide corrosion-resistant steel conforming to ASTM A1008/A1008M , and ASTM A167, Type [302] [304] [316] Finish 4 .
Provide glass conforming to ASTM C1036, Type I, Class 1, Quality q3, 1/4 inch thick, for unframed sliding glass doors; other glass is to conform to ASTM C1036, Type II, Class 1, Quality q8, 7/32 inch thick.
Use thermosetting urea-resin Type II Adhesives for application of plastic laminate conforming to ASTM D4690 as recommended by the manufacturer of the laminate. Use adhesive conforming to ASTM D4689 for wood members.
Provide filler material conforming to FS TT-F-336 .
Provide plastic laminate conforming to ANSI/NEMA LD 3 , Style [_____], Type [_____], Grade [_____], Class [_____], Finish [_____].
SECTION 12 31 00 Page 4
Provide accessories and hardware conforming to the following requirements, as applicable:
Extension drawer slides: ANSI/BHMA A156.9 , Type B85071.
[ Semiconcealed hinges: ANSI/BHMA A156.9 , Type B81201, 1-1/2 inches. ]
[ Full surface hinges: ANSI/BHMA A156.9 , Type B81131, 1-1/2 inches. ]
[ Knob pulls: ANSI/BHMA A156.9 , 1-inch diameter, Type B12132 ]
[ Bar type pulls: ANSI/BHMA A156.9 , 4-inch overall length, Type B12012. ]
Locks, keying, and keys: As directed.
Catches: Magnetic, 5-pound pull.
Sliding door set:
Impregnated fiberboard track
Nylon glides
Provide Fasteners conforming to the following:
Screws: Complying with ANSI Standards, Group, Type and Class as applicable.
Anchoring Devices: FS FF-S-325 , Group, Type, and Class as applicable.
Toggle bolts: FS FF-B-588 , Type I, Class A, Style 2.
Nuts: ASTM F594, corrosion-resistant steel.
Bolts: ASTM A325, heavy, hexagon head bolts corrosion-resistant steel.
Nuts: ASTM F836M, corrosion-resistant steel.
Bolts: ASTM A325M, heavy, hexagon head bolts corrosion-resistant steel.
Corrosion-resistant Steel Sinks:
[ 18-gauge corrosion-resistant steel, integral with corrosion-resistant steel countertop
][ 18-gauge corrosion-resistant steel, nonintegral, self-rimming
] Drain holes in center of bowl
Underside coated with 1/8-inch thick sound deadener
Die-form, seamless, raised edges at front and ends
Cove corners to 1/2-inch radius
Equip with strainers and tail pieces
SECTION 12 31 00 Page 5
Provide Service Fixtures conforming to the following requirements:
a. Provide fixtures in accordance with the water conservation policy as stated in the ICC IPC .
b. Faucets:
(1) Splashback mounted, cast brass, chrome plated, FS WW-P-541
(2) Deck mounted, cast brass, chrome plated, FS WW-P-541
c. Gas, air, and vacuum, distilled water, steam, and de-ionized water cocks: cast brass, chrome plated, ground key type
d. Drains, strainers, and taps: brass, chrome plated, FS WW-P-541
e. Index buttons: plastic, color codes in accordance with SEFA 7
f. Special items: provide nipples and locknuts with each fixture.
[ Metal pretreatment coatings: FS TT-C-490 , Type I
][ Metal pretreatment coatings: FS TT-C-490 , Type II
][ Metal pretreatment coatings: FS TT-C-490 , Type III
][ Enamel: FS TT-E-491 , Class 2
] 2.3 STEEL CABINET FABRICATION
2.3.1 General
Provide wall and base cabinets fabricated from22-gauge, cold-rolled furniture steel, except for backs of cabinets and backs of doors provide 24-gauge steel. Construct cabinets with no raw edges or exposed flanges, with welds being flush and ground smooth on all exposed surfaces. Provide concealed fasteners at all exposed exterior surfaces. Provide doors and drawer fronts with panelized double-wall construction, not less than 1/2-inch thick, with a sound-absorbing material adhered between the walls. Equip doors and drawers with rubber or plastic silencers and bumpers. Provide drawers with removable fronts, mounted on [ metal guides ] [renewable fiber guides] [plastic guides] and equipped with position stops for complete drawer withdrawal. Provide [fixed] [ adjustable ] shelving as indicated.
2.3.2 Workmanship
Align end panels, top rails, bottoms and vertical posts at intersections in same plane, without overlap. Grind exposed welds flush and smooth.
Welding is to conform to AWS D1.1/D1.1M and AWS D1.3/D1.3M .
Additional casework construction requirements:
a. Welded assembly.
b. Fabricate with enclosed uprights or posts full height or width at front, include sides, backs, bottoms, soffits, ceilings under sloping tops, headers and rail, assembled to form an integral unit.
SECTION 12 31 00 Page 6
c. Form sides to make rabbeted stile 3/4 to 1-1/8 inch wide, closed by channel containing shelf adjustment slots.
d. Make bottom of wall units flush, double panel construction.
e. Make top and cross rails of "U" shaped channel.
f. Enclose all backs and bottoms in cabinets, including drawer units.
g. Provide finish panel on exposed cabinet backs.
h. Do not use screws and bolts in construction or assembly of casework, except to secure hardware, applied door stops, accessories, removable panels and where casework is required to fastened end to end or back to back.
i. Fabricate casework, except benches, and desks with finished end panels.
j. Close flush exposed soffits of wall hung shelving, knee spaces in counters, and toe spaces at bases.
k. In base units with sinks provide on piece, lowered backs.
l k. In base units with doors provide removable backs.
ml . Provide built-in raceways or tubular or channel shaped members of casework for installation of wiring and electric work. Mount junction boxes on rear of cabinets. Electric work is specified in electrical sections of specifications.
nm. Provide reinforcing for hardware.
on. Size Dimensions:
(1) Used dimensions shown or specified within tolerances specified.
(2) Tolerance:
(a) Depth: 13 inches in lieu of 12 inches, 18 inches in lieu of 16 inches, except wall hung units above counter 21 inches to 24 inches in lieu of 22 inches.
(b) Width: Minus 1 inch.
(c) Height: 1 inch plus or minus for wall hung cabinets and counter mounted cabinets, excluding sloping tops. 1 inch plus for floor standing cabinets,excluding base and sloping tops. Full height cabinets shown back to back same height.
(d) Manufacturer's tolerance for the length, depth or height: Not to exceed 0.0625-inches.
SECTION 12 31 00 Page 7
2.3.3 Minimum Thickness of Steel
U. S. Standard Thickness
GAUGE
(INCH)
Drawer fronts, backs, bodies, closure plates or scribe and filler strips less than 75 mm wide,filler strips less than 75 mm wide, sloping top, shelf reinforcement channel and shelves. Toe space or casework soffits and ceilings and ceilings under sloping tops.
20 0.035
Base pedestals, casework top sides, back, and bottom panels, closure scribe and filler strips 75 mm or more. Reinforcement for drawers with locks. Table legs, spreaders and stretchers, when fabricated of cold rolled tubing.
Metal for desks; except legs and aprons. Door exterior and interior panels, flush or glazed.
Cross rails of base units. Front bottom rails, back bottom rails;
rails may be 1.49 mm 16 gauge thick. Uprights or posts. Top corner gussets.
18 0.047
Aprons, apron division, reinforcing gussets, table legs, desk legs and aprons, spreaders and stretchers when formed without welding. Toe base gussets, drawer slides, and other metal work.
Front top rails and back rails except top back rails may be 1.2 mm 18 gauge thick.reinforcing gussets, table legs, desk legs and aprons, spreaders and stretchers when formed without welding. Toe base gussets, drawer slides, and other metal work. Front top rails and back rails except top back rails may be 1.2 mm 18 gauge thick.
16 0.059
Drawer runners door tracks 14 1.88
SECTION 12 31 00 Page 8
U. S. Standard Thickness
GAUGE
(INCH)
Base unit bottom corner gussets and leg sockets
12 0.104
Reinforcement for hinge reinforcement inside doors and cabinets
12 3
2.3.4 Cabinets
Provide cabinets with sheet steel fronts, backs, sides, tops, and bottoms.
Form sides with rabbeted stiles 1-1/8-inches wide, closed by welded channel containing embossed louvers spaced 1-1/2-incheson center, for adjustable shelves.
Provide cabinets that have a steel channel-shaped top rail, 18-gauge steel cross rails, and Z-shaped rear rail to engage 16-gauge steel hanging bracket.
At base cabinets, provide 1-1/2-inch long leveling screws for adjusting to floor variations that are accessible through plugged openings in bottom;
install 14-gauge gussets to support the screws.
At base cabinets, provide removable backs, knee space panels, or access doors where piping occurs.
2.3.5 Doors
Provide doors that are double-pan construction with 5/8-inch thick telescoped inner pan into outer pan with exposed vertical edge formed into channel shape having returned lip over inner pan and offset to receive lip.
Coat panels with 1/8-inch thick asphaltic sound deadener.
Fasten reinforcement for hardware attachment to inner pan and conceal.
Fit hinged doors with pairs of hinges, knob pulls, locks, and bumpers.
Bevel inside edge of cutout in front panel of glass door.
Set glass in continuous rubber gasket between panels.
Equip sliding doors with tracks, guides, bumpers, and bar pulls.
Additional considerations for doors:
a. Hollow metal type, flush and glazed doors not less than 5/8 inch thick.
b. Fabricate flush metal doors of two panels formed into pans with corners welded and ground smooth. Provide flush doors with a sound deadening core.
c. Fabricate glazed metal doors with reinforced frame and construct
SECTION 12 31 00 Page 9 either from one piece of steel, or have separate stiles and rails mitered and welded at corners, and welds ground smooth.
(1) Secure removable glazing members with screws to back of doors.
(2) Install glass in rubber or plastic glazing channels.
d. Provide sheet steel hinge reinforcement inside doors.
e. Sliding doors: Provide stops to prevent bypass.
f e. Doors removable without use of tools except where equipped with locks.
2.3.6 Drawers
Provide drawer fronts that are double-pan construction with 5/8-inch thick telescoped inner pan into outer pan with exposed vertical edge formed into channel shape having return lip over inner pan and offset to receive lip.
Weld drawer bodies to front through flanges on sides and bottom, and to back through flanges at rear.
Extend flanges outward or downward, top of side, and backrolled.
Cove corners to 1/2-inch radius.
Provide drawer accessories including slides, bar pulls, lock and stop devices.
Additional considerations for drawers:
a. Drawer fronts flush hollow metal type not less than 5/8-inch thick with sound deadening core. Fabricate of two panels formed into pans.
Weld and grind smooth corners of drawer fronts.
b. Form bodies from one piece of steel, weld to drawer front.
c. Provide reinforcement for locks and provide rubber bumpers at both sides of drawer head to cushion closing.
d. Equip with roller suspension guides.
2.3.7 Shelves
[ Fabricate shelves from sheet steel with front and rear edges flanged down 3/4-inch and hemmed back at 30 degrees to underside of shelf.
][ Fabricate shelves from corrosion-resistant steel sheet with front and rear edges flanged down 3/4-inch and hemmed back at 30 degrees to underside of shelf.
] Support shelves with 16-gauge shelf clips inserted in slots in front stile and in form channel in back.
Notch flanges at sides to match and engage with embossments on side panels.
Additional considerations for shelves:
a. Capable of supporting an evenly distributed minimum load of (twenty-five pounds per square foot) without visible distortion.
SECTION 12 31 00 Page 10
b. Flange shelves down 3/4-inch on edges, with front and bearing edges flanged back 1/2 inch.
c. For shelves over 42-inches in length and over 12 inches in depth install 1-1/2 by 1/2 by 0.0359 inch thick sheet steel hat channel reinforcement welded to underside midway between front and back and extending full length of shelf.
d. Weld shelves to metal back and ends unless shown adjustable.
ed. Provide means of positive locking shelf in position, and to permit adjustment without use of tools.
f. On pharmacy on sloping shelf provide 1/2-inch wide clear acrylic plastic raised edge, 1/8-inch thick, secured to front edge of shelf.
2.3.8 Dustcover Tops
Provide front face height of 1-inch.
Slope dustcover tops upward 30 degrees from front to back of cabinet.
Equip dustcover tops for attaching from inside of cabinet.
Additional considerations for sloping tops:
a. Provide sloping tops for casework where shown.
b. Where ceilings interfere with installation of sloping tops. Provide filler plates as specified.
c. Omit sloping tops or filler plates whenever ceiling material is turned down and furred-in at face of casework.
d. Provide exposed ends of sloping tops with flush closures.
e. Fasten sloping tops with sheet metal screws inserted from cabinet interior; space fastener as recommended by manufacturer.
2.3.8 Finish
Prime and factory finish steel cabinets with two coats of synthetic enamel, baking quality, conforming to FS TT-E-489 , Class B. Provide colors as selected.
2.3.9 Welded Cabinets
Conform to KCMA A161.1 , all welded construction.
[ 2.3.10 Doors and Drawer Fronts
Doors and Drawer Fronts may be as specified for wood cabinets in lieu of metal pan construction.
] 2.3.11 Undercounter Table and Bench Frames
Requirements for undercounter table and bench frames:
a. Using welded construction.
SECTION 12 31 00 Page 11
b. Open frame type with aprons and legs when required.
c. Aprons:
(1) Channels shaped welded at corners, with leg sockets and reinforcing triangular corner gussets welded in corners;
12301-9.
(2) Pierce sockets to receive leg bolts and notch gussets to receive legs.
(3) Upper flange perforated or slotted to receive screws at 8-inch centers, and back channels when installed against wall. Sizes lots for 1/4-inch anchor bolts.
(4) Pierce aprons to receive drawer formation, rail at top of drawer opening. Install channel shaped apron division welded at ends, 30-inches apart to front and back aprons, or at each side of drawer.
(5) Fabricate metal components from sheet steel.
(6) Use 0.0598-inch thick sheet for gussets and channel aprons.
(7) Use 0.0478-inch thick sheet for other items.
(8) At knee space, provide exposed metal sides and metal closure plate for soffit. Where shown at knee space, provide exposed metal back secured with continuous angle closures at both side.
d. Legs:
(1) Cold rolled tubing or 0.0598-inch formed steel.
(2) Leveling-anchoring device at floor.
(3) Stud bolt at top for attachment to leg socket.
e. Leg Braces:
(1) Tables and benches not anchored to walls.
(2) Brace back against front legs near bottom with steel angle channel or tubular braces.
(3) Fasten braces together with steel straps.
f. Leg Shoes:
(1) Fit laboratory casework legs at bottom with either stainless steel, aluminum, or chromium plated brass shoes, not less than one inch in height.
(2) Fit other legs with a movable molded vinyl shoe 4 inches high and coved at bottom.
SECTION 12 31 00 Page 12
2.3.12 Closures and Filler Strips at Pipe Spaces
Requirements for closures and filler strips at pipe spaces:
a. Flat steel strips or plates.
b. Openings less than 8-inches wide: 0.047-inch thick.
c. Openings more than 8-inches wide 0.359-inches wide.
[ 2.4 MISCELLANEOUS CABINETS
[ 2.4.1 Combination Sink-and-Base Cabinet
A combination sink-and-base cabinet unit may be furnished in lieu of the base cabinet and inset sink indicated provided the combination unit affords facilities and space equal to those indicated and provided the combination unit matches the adjacent units in materials and construction. Provide sink, with matching drainboards, made of [corrosion-resistant steel] [porcelain-enamel steel] and equipped with a chromium-plated [swinging-spout faucet, chromium-plated water-control valves,] [automatic faucet] and chromium-plated cup strainer. Make joints between sink and drainboard and between drainboard and counter top watertight.
][ 2.4.2 Special Purpose Cabinets
Provide special-purpose cabinets, such as cabinets for eye-level oven units, countertop range units, and built-in refrigerators as indicated[ on the drawings,] and of the same materials and construction as adjacent cabinets. Provide space adjacent to sink for a dishwasher, as indicated.
] ] 2.4 ACCESSORIES AND HARDWARE
Furnish accessories such as utility shelves and racks for extracts, condiments, and towels; bins for sugar and flour; breadboxes; and trays for cutlery and flatware as indicated.
Provide corrosion resistant hardware. Provide exposed hardware with a chromium-plated finish or a corrosion-resistant finish as approved. Paint semi-concealed hinges on cabinets where paint finish is required to match the cabinets. Equip doors with [ bullet-type catches ] [spring hinges] [magnetic-type catches] . Provide door and drawer pulls as indicated.
2.5 CABINETS
The work includes providing new factory-finished kitchen wall and base cabinets with:
[ a. High pressure decorative laminate (HPDL)
][ b. Granite countertops
][ c. Marble countertops
][ d. Synthetic resins countertops
][ e. ffrp countertops
SECTION 12 31 00 Page 13
][ f. Stainless steel countertops
][ g. Tile countertops
][ h. [_____] custom countertops
] Bathroom vanity cabinets [with HPDL countertops][to receive combination lavatory-countertops as specified in Section 22 00 00 PLUMBING, GENERAL
PURPOSE].
Provide cabinets conforming to KCMA A161.1 , and bear the "KCMA Certified Cabinet" seal of the Kitchen Cabinet Manufacturers Association. Provide Countertops that conform to NEMA LD 3.1 and requirements specified herein.
2.5.1 Cabinet Locks
Requirements for cabinet locks:
a. Where locks are shown.
b. Locked pair of hinged door over 36 inches high:
(1) ANSI/BHMA A156.5 , similar to E0261, key one side.
(2) On active leaf use three-point locking device, consisting of two steel rods and lever controlled cam at lock, to operate by lever having lock cylinder housed therein.
(3) On inactive leaf use dummy lever of same design.
(4) Provide keeper holes for locking device rods and cam.
(5) Use two point locking device both doors of cabinet 6D similar to ANSI/BHMA A156.5 , E0251, key one side.
c. Door and Drawer: ANSI/BHMA A156.11 cam locks.
(1) Drawer and Hinged Door up to 36-inches high: E07261.
05-03M 12301-11
(2) Pin-tumbler, cylinder type lock with not less than four pins. Disc tumbler lock "duo A" with brass working parts and case, as manufactured by Illinois Lock Company are acceptable.
(3) Sliding Door: E07161.
d. Key locks differently for each type casework and master key for each service, such as Nursing Units, Psychiatric, Administrative, Pharmacy.
(1) Key drug locker inner door different from outer door.
(2) Provide two keys per lock.
(3) Provide six master keys per service or Nursing Unit.
e. Marking of Locks and Keys:
(1) Name of manufacturer, or trademark which can readily be identified legibly marked on each lock and key change number marked on
SECTION 12 31 00 Page 14 exposed face of lock.
(2) Key change numbers stamped on keys.
(3) Key change numbers to provide sufficient information for manufacturer to replace key.
2.5.1 Cabinet Hardware
Comply with ANSI/BHMA A156.9 .
Requirements for cabinet hardware:
a. Door/Drawer Pulls: B02011.
(1) One for drawers up to 23-inches wide.
(2) Two for drawers over 23-inches wide.
(3) Sliding door flush pull, each door: B02201.
[ b. Door in seismic zones: B03352.
(1) Do not provide thumb latch on doors equipped with three point locking device.
(2) Use lever operated two point latching device on paired doors over 36-inches high if three point locking or latching device is not used.
] c. Cabinet Door Catch:
(1) Install at bottom of wall cabinets, top of base cabinets and top and bottom of full height cabinet doors over 48-inches.
(2) Omit on doors with locks.
db. Drawer Slides:
(1) Use B05051 for drawers over 6-inches deep.
(2) Use B05052 for drawers 3 to 6-inches deep.
(3) Use B05053 for drawers less than 3-inches deep.
2.6 FINISH
2.6.1 Cabinet Finish
Provide cabinets with a factory-applied durable finish in accordance with KCMA A161.1 requirements and of a type standard with the manufacturer.
2.7 COLOR, TEXTURE, AND PATTERN
Provide color [in accordance with Section 09 06 00 SCHEDULES FOR FINISHES.] [ as indicated on the drawings. ] [as selected from manufacturers standard colors.] [[______.] Color listed is not intended to limit the selection of equal colors from other manufacturers. ]
SECTION 12 31 00 Page 15
[ 2.8 DISPENSING TRAYS AND BINS
Requirements for dispensing trays and bins:
a. Design trays and bins to fit cabinets where shown.
b. Fabricate of steel, polypropylene, fiberglass reinforced polyester resin, or other suitable material.
c. Lock securely in place without the use of tools.
d. Fit at angle to provide gravity feed where shown.
e. Dispensing Trays:
(1) Equip trays with two longitudinal dividers adjustable to three position.
(2) Approximate dimensions: 6-inches in width 3-inches (in depth, and length to suit cabinets depth furnished.
f. Dispensing Bins:
(1) Open front, except for retaining rim. 05-03M 12301-14
(2) Approximate dimensions: 6-inches in width, 5-inches in depth, and length to suit cabinets furnished.
][ 2.9 ELECTRICAL FIXTURES
Requirements for dispensing electrical fixtures:
a. Comply with requirements of DIVISION 26 ELECTRICAL specifications for fixtures, receptacles, wiring and junction boxes required for fixtures and receptacles, included with casework.
b. Suitable for use with electrical system specified and shown.
c. Factory install in casework.
][ 2.10 SUSPENSION SYSTEM FOR INTERCHANGEABLE CASEWORK
Requirements for dispensing suspension systems for interchangeable casework:
a. Provide a suspension system for independent suspension of interchangeable under-counter cabinets and of countertops. Provide for removal or exchange of under counter cabinets of various heights, widths and types, and for vertical adjustment of counter tops to heights indicated on drawings.
b. Suspension Frames: Fabricate from 1-1/4-inch square or x 1-1/2-inch rectangular, 0.104-inch 12 gauge steel tubing welded to form full rectangle. Provide integral, adjustable leveling device in steel leg with non marring foot cap.
c. Provide mounting channels and support frames which allow for pipe chases and service channels when required.
SECTION 12 31 00 Page 16
d. Provide cabinets with a .059-inch steel shaped form welded across the entire width of back to engage a continuous slot in a wall mounting channel. Provide final positive location and locking of case in position with two fastening devices through case stile at front.
e. Paint all construction materials that are exposed.
][ 2.11 WHEELED CARRIER
Provide a wheeled carrier to facilitate installation, removal, and transport of interchangeable cases as part of the interchangeable [laboratory ]furniture system.
] PART 3 EXECUTION
3.1 INSTALLATION
Install casework as described in manufacturers installation drawings in accordance with design intent.
a. Level base cabinets by adjusting leveling screws.
b. Secure cases permanently to floor and wall construction, where applicable.
c. Secure wall cases in position with screws to blocking, where applicable.
d. Bolt adjoining cases together.
e. Align doors, adjust hardware, and clean surfaces.
3.1.1 Coordination
Before installing casework, verify wall and floor surfaces covered by casework have been finished.
Verify location and size of mechanical and electrical services as required.
Verify reinforcement of walls and partitions for support and anchorage of casework.
3.1.2 Fastenings and Anchorage
Do not anchor to wood ground strips.
Provide hat shape metal spacers where fasteners span gaps or spaces 05-03M 12301-16.
Use 1/4-inch diameter toggle or expansion bolts, or other appropriate size and type fastening device for securing casework to walls or floor. Use expansion bolts shields having holding power beyond tensile and shear strength of bolt and breaking strength of bolt head.
Use 1/4-inch diameter hex bolts for securing cabinets together.
Use 1/4-inch by minimum 1-1/2-inch length lag bolt anchorage to wood blocking for concealed fasteners.
SECTION 12 31 00 Page 17
Use not less than No. 12 or 14 wood screws with not less than 1-1/2-inch penetration into wood blocking.
Space fastening devices 12-inches on center with minimum of three fasteners in 3 or 4-foot unit width.
Anchor floor mounted cabinets with a minimum of four bolts through corner gussets. Anchor bolts may be combined with or separate from leveling device.
Secure cabinets in alignment with hex bolts or other internal fastener devices removable from interior of cabinets without special tools. Do not use fastener devices which require removal of tops for access.
Where units abut end to end anchor together at top and bottom of sides at front and back. Where units are back to back anchor backs together at corners with hex bolts placed inconspicuously inside casework.
Where type, size, or spacing of fastenings is not shown or specified, show on shop drawings proposed fastenings and method of installation.
3.1.3 Closures and Filler Plates
Close openings larger than 1/4-inch wide between cabinets and adjacent walls with flat, steel closure strips, scribed to required contours, or machined formed steel fillers with returns, and secured with sheet metal screws to tubular or channel members of units, or bolts where exposed on inside.
Where ceilings interfere with installation of sloping tops, omit sloping tops and provide flat steel filler plates.
a. Secure filler plates to casework top members, unless shown otherwise.
b. Secure filler plates more than 6-inches in width top edge to a continuous 1 by 1 inch, 0.035-inches thick steel formed steel angle with screws.
c. Anchor angle to ceiling with toggle bolts, 05-03M 12301-17.
Install closure strips at exposed ends of pipe space and offset opening into concealed space. Paint closure strips and fillers with same finishes as cabinets. Caulk and seal laboratory furniture as specified in Section
07 92 00 JOINT SEALANTS.
3.1.4 Cabinets
Install in available space; arranged for safe and convenient operation and maintenance. Align cabinets for flush joints except where shown otherwise.
Install cabinets level with bottom of wall cabinets in alignment and tops of base cabinets aligned. Install corner cabinets with hinges on corner side with filler or spacers sufficient to allow opening of drawers.
Plug Buttons:
a. Install plug buttons in predrilled or prepunched perforations not used.
b. Use chromium plate plug buttons or buttons finish to match adjacent
SECTION 12 31 00 Page 18 surfaces.
Cabinets 6D: Ground to nearest cold water pipe in accordance with NFPA, Underwriters Laboratories, Inc., or other nationally recognized laboratory approved ground specified system.
Cabinets PH77:
a. Install undercounter unit, PH77U, on base to bring cabinet to same height as adjacent cabinets.
b. Install wall hung units, PH77N, as for wall cabinets, bolt together with security type bolts.
c. Install stacked units, PH77D, bolted together and to base with security type bolts.
3.2 CLEANING
Remove crating and packing materials from premises. Wipe down surfaces to remove fingerprints and markings and leave in clean condition.
3.3 FIELD QUALITY CONTROL
3.3.1 Inspection
Examine casework grounds and supports for adequate anchorage, foreign material, moisture, and unevenness that could prevent quality casework installation. Ensure that electrical and plumbing rough-ins for casework are complete. Do not proceed with installation until defects are corrected.
-- End of Section --
SECTION 12 31 00 Page 19
SECTION 12 50 00.13 10
FURNITURE AND FURNITURE INSTALLATION
08/17
PART 1 GENERAL
Purchase and install furniture as identified within this specification.
This specification section includes a Furniture, Fixtures and Equipment (FF&E) Package attachment. [
The requirements of this specification also apply to systems furniture unless otherwise specified in Section 12 59 00 Systems Furniture. ]
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING
ENGINEERS (ASHRAE)
ASHRAE 90.1 - IP (2013) Energy Standard for Buildings Except Low-Rise Residential Buildings
ASTM INTERNATIONAL (ASTM)
ASTM D4157 (2013; R 2017) Standard Test Method for Abrasion Resistance of Textile Fabrics (Oscillatory Cylinder Method)
BIFMA INTERNATIONAL (BIFMA)
ANSI/BIFMA X5.1 (2017) American National Standards For Office Furnishings - General Purpose Office Chairs
ANSI/BIFMA X5.5 (2014) American National Standards For Office Furnishings -Desk Products
ANSI/BIFMA X5.9 (2012) American National Standards For Office Furnishings - Storage Units
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2018; ERTA 18-1; ERTA 18-2; ERTA 18-3;
ERTA 18-4; TIA 18-1; TIA 18-2; TIA 18-3;
TIA 18-4) Life Safety Code
NFPA 260 (2013) Standard Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture
SECTION 12 50 00.13 10 Page 1
STATE OF CALIFORNIA DEPARTMENT OF CONSUMER AFFAIRS, BUREAU OF
ELECTRICAL AND APPLIANCE REPAIR, HOME FURNISHINGS AND THERMAL
INSULATION (BEARHFTI)
TB 117-2013 (2013) Requirements, Test Procedure and Apparatus for Testing the Smolder Resistance of Materials Used in Upholstered Furniture
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a " GF" designation are for [Contractor Quality Control approval.] [ information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. ] Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 .00 06 SUSTAINABILITY REPORTING. Submit the following in accordance with Section
01 33 00 .00 06 SUBMITTAL PROCEDURES:
SD-01 Preconstruction Submittals
Storage Location; G RO[, [_____]]
SD-02 Shop Drawings
Installation Drawings; G RO[, [_____]]
[ Grommet[ , Power and Communication Units ][ , and Wire Management ] Locations; G RO[, [_____]] ]
SD-03 Product Data
Product Data; G [, [_____]]
Product Style Options; G [, [_____]]
SD-04 Samples
Fabric and Finishes; G RO[, [_____]]
SD-07 Certificates
Authorized Dealer; G RO[, [_____]]
Certified Furniture Installers; G [, [_____]]
Licensed Electrician; G [, [_____]]
Certified Telecommunications Installer; G [, [_____]]
Manufacturer's Certification; G RO[, [_____]]
SECTION 12 50 00.13 10 Page 2
Warranty; G RO[, [_____]]
SD-10 Operation and Maintenance Data
Furniture, Data Package 1; G [, [_____]]
SD-11 Closeout Submittals
Energy Efficient Equipment; S
Reduced VOC's for Furniture; S
Recycled Content of Furniture; S
Bio-Based Content of Furniture; S
1.3 SERVICES
Provide services to include furniture purchase, field measuring, installation drawings, shipping and delivery coordination, receiving, inspection, submitting and processing freight and warranty claims, unpacking, storing, assembly, installation and other related activities or tasks for a complete and functional installation. Reference Section 01 45 00.00 10 QUALITY CONTROL for inspection requirements. The Contracting Officer must be allowed to participate in inspections. [ In addition provide services for existing furniture as specified, reference paragraph on EXISTING FURNITURE for more information. ] Develop project timelines and establish shipping, receiving and installation dates that coordinate with the building construction schedule. Hold at a minimum weekly team meetings to brief the project team, include the Contracting Officer. Notify the Contracting Officer immediately of any scheduling problems, discontinued furniture items including fabrics and finishes, or other conditions which may cause delays, and recommend available substitutes, solutions, and provide updated timeline to coordinate with building construction schedule. Substitutes and solutions must comply with the specification and be approved by the Contracting Officer.
1.4 FURNITURE PURCHASE
Purchase furniture, including checking accuracy of all acknowledgements and schedules from manufacturers and making necessary corrections to insure that the manufacturer has a correct understanding of the order and requirement. [ Provide furniture from the GSA Schedules and provide GSA pricing. Provide furniture from open market only when an item is not available on the GSA Schedules. See FAR clause 52.251-1 Government Supply Sources.][ Purchase furniture from the open market. The furniture provided needs to be available on the GSA Schedules to assist the User with future purchases. GSA information is provided FOR INFORMATIONAL PURPOSES ONLY. It is encouraged to solicit and provide GSA pricing on furniture. ] Compete the furniture purchase by obtaining a minimum of (3) separate proposals. Furniture is subject to FAR clause 52.236-5 Materials and Workmanship. [ If necessary to meet project timeline requirements, furniture may be purchased using manufacturers quick-ship programs or by coordinating factory times.]
1.5 ALTERNATE DESIGN
When a manufacturer's product is unable to provide desk and workstation
SECTION 12 50 00.13 10 Page 3 configurations and filing/storage that conform exactly to the furniture layouts shown in the contract drawings and specifications, alternate designs may be submitted for consideration by the Contracting Officer.
Alternate designs must meet or exceed the following criteria. Alternate designs that are submitted but do not meet these criteria will be rejected.
1.5.1 Desk and Workstation Size and Configuration
The alternate design must provide desks and workstations of the same basic size and configuration shown, with only the sizes of the individual components within the desk and workstation changed to meet the standard product of the manufacturer.
1.5.2 Filing and Storage Size and Configuration
The alternate design must provide filing and storage of the same basic size and configuration shown, with only the size changed to meet the standard product of the manufacturer. The storage capacity must not be reduced.
1.5.3 Furniture Requirements
The furniture provided must comply with the drawings, specifications, and the requirements identified in the FF&E Package Attachment.
1.5.4 Layout
The storage capacity, number of desks and workstations, number of persons accommodated, width of aisles, and functionality must be maintained.
Layout must comply with NFPA 101 and 36 CFR 1191 .
1.6 AUTHORIZED DEALER, CERTIFIED FURNITURE INSTALLERS, LICENSED
ELECTRICIAN AND CERTIFIED TELECOMMUNICATIONS INSTALLER
When required by the furniture manufacturer, furniture must be installed by an authorized dealer and a certified furniture installation crew must be used on the project. [ Services provided to reuse existing furniture must comply with manufactures warranty requirements to maintain warranty.
If warranty for existing furniture to be reused has expired, services must be completed by a furniture installation crew with a minimum of 5 years experience. ] All furniture requiring hardwiring must be completed by a licensed electrician. Communications installers must be Building Industry Consulting Services International (BICSI) Registered Cabling Installers, Technician Level or have a minimum of [ 3][_____] years experience in the installation of the specified cables and components. All installers, furniture, electrical and communications, must be on-site if questions arise.
This is the start of the file's text. The full file is on GovTribe.