W912QR21R0051_SID-0000.pdf
PDF 4 MB Posted
- Solicitation number
- W912QR21R0051
About this file
This document package includes a solicitation for a federal construction contract opportunity and related project files. The solicitation is for lab renovations for the XTAL Building 654 at Wright-Patterson Air Force Base, OH, with an estimated construction cost between $5-10 million. The NAICS code is 236220, with a size standard of $39.5 million. The solicitation requires compliance with CCR/ORCA requirements through SAM and adherence to the HUBZone 10% price evaluation preference. An organized site visit is scheduled for July 1, 2021 at 9 AM ET, with an RSVP deadline of June 28, 2021. The related project files provide design and construction details, including room finish schedules, signage schedules, and plans showing wall finishes, floor finishes, and signage placements.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation For XTAL Renovations Project Bldg 654 Wright-Patterson AFB, OH
P2: 487666
Design Bid Build
SID
Certified Final Design Submittal
23 June 2021
W912QR21R0051
ARIMS: 200A
Disposition: Maintain for 15yrs after construction
W912QR21R0051-0000
P2#487666 XTAL Renovation Project CERTIFIED FINAL DESIGN SUBMITTAL Wright-Patterson AFB, OH
THIS PAGE INTENTIONALLY LEFT BLANK
XTAL RENOVATION PROJECT
WRIGHT-PATTERSON AFB, OH
RTA DESIGN SUBMITTAL
STRUCTURAL INTERIOR DESIGN (SID)
MAY 2021
XT
A
L R en ov at io n P ro je ct W rig ht
P at te rs on , A
FB
, O
H
TABLE OF CONTENTS:
FLOOR FINISHES
WALL FINISHES
CEILING FINISHES
MISC. FINISHES
DRAWINGS
L R en ov at io n P ro je ct W rig ht
P at te rs on , A
FB
, O
H
FLOOR FINISHES
RF-1
DESCRIPTION: 12” x 12” RESILIENT TILE
MANUFACTURER: ARMSTRONG
PRODUCT / STYLE: VCT
COLOR: 51904 STERLING SILVER
SV-1
DESCRIPTION: PCV-FREE HEMOGENEOUS
SHEET FLOORING
MANUFACTURER: ARMSTRONG
PRODUCT / STYLE: MEDINPURE WITH DIA-
MOND 10 TECHNOLOGY
COLOR: MIRROR LAKE H6004
WOM-1
DESCRIPTION: 24” X 24” WALK OFF MAT
MANUFACTURER: SHAW CONTRACT
PRODUCT / STYLE: PORTAL TILE 5T035
COLOR: MULTICOLOR 34481
L R en ov at io n P ro je ct W rig ht
P at te rs on , A
FB
, O
H
WALL FINISHES
PA-1 / PE-1
DESCRIPTION: PAINT
MANUFACTURER: SHERWIN WILLIAMS
PRODUCT / STYLE: ACRYLIC, LATEX / EPOXY
COLOR: SW7070 SITE WHITE
PA-2 / PE-2
DESCRIPTION: PAINT
MANUFACTURER: SHERWIN WILLIAMS
PRODUCT / STYLE: ACRYLIC, LATEX / EPOXY
COLOR: SW6228 REFUGE
PA-3
DESCRIPTION: PAINT
MANUFACTURER: SHERWIN WILLIAMS
PRODUCT / STYLE: ACRYLIC / LATEX
COLOR: SW7007 CEILING BRIGHT WHITE
L R en ov at io n P ro je ct W rig ht
P at te rs on , A
FB
, O
H
CEILING FINISHES
ACT-1
DESCRIPTION: 24” X 24” ACOUSTICAL CEILING TILE
MANUFACTURER: ARMSTRONG
PRODUCT / STYLE: CLEAN ROOM FL, 15/16” CLEANROOM GRID
COLOR: WHITE WITH GRAY SPATTER
L R en ov at io n P ro je ct W rig ht
P at te rs on , A
FB
, O
H
MISC. FINISHES
CG-1
DESCRIPTION: CORNER GUARD
MANUFACTURER: KOROSEAL
PRODUCT / STYLE: GS15
COLOR: STAINLESS STEEL
RB-1
DESCRIPTION: 4” RUBBER BASE
MANUFACTURER: ROPPE
PRODUCT / STYLE: PINNACLE TS / 1/8”
COLOR: 100 BLACK
DRAWINGS
XTAL RENOVATION PROJECT
WRIGHT PATTERSON, AFB, OH MAY 2021
GENERAL ROOM FINISH SCHEDULE NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
REFER TO SPECIFICATIONS FOR THE BASIS OF DESIGN OR
EQUIVALENT MANUFACTURER TECHNICAL REQUIREMENTS.
REFER TO INTERIOR ELEVATIONS, REFLECTED
CEILING DRAWINGS, FLOOR FINISH DRAWINGS, WALL FINISH
DRAWINGS, ENLARGED PLAN DRAWINGS AND INTERIOR DETAIL
DRAWINGS FOR ADDITIONAL FINISH PLACEMENT INFORMATION.
REFER TO ELECTRICAL DRAWINGS, MECHANICAL DRAWINGS,
STRUCTURAL DRAWINGS AND COMMUNICATION DRAWINGS
FOR COORDINATION OF BUILDING FINISHES TO BUILDING
SYSTEMS.
REFER TO FLOOR FINISH DRAWINGS FOR PLACEMENT OF
FLOOR FINISHES, FLOOR PATTERNS AND FLOOR MATERIAL
CHANGES. REFER TO FLOORING TRANSITION DETAILS FOR
TRANSITIONS BETWEEN ADJOINING FLOORING MATERIALS.
REFER TO WALL FINISH DRAWINGS AND INTERIOR ELEVATIONS
FOR WALL FINISH EXTENTS, CORNER GUARD LOCATIONS,
SIGNAGE, ART AND SPECIALTY WALL FINISH LOCATIONS.
REFER TO REFLECTED CEILING DRAWINGS FOR CEILING
HEIGHTS AND CEILING MATERIAL EXTENTS.
PROVIDE BLOCKING AS REQUIRED TO SECURE ALL WALL
MOUNTED ITEMS INCLUDING TOILET FIXTURES, TOILET
ACCESSORIES, TOILET PARTITIONS, MILLWORK, SHELVES,
COUNTERTOP SUPPORTS, MARKERBOARDS, TACKBOARDS,
FLAT PANEL DISPLAYS, CAMERAS, ACOUSTICAL WALL PANELS,
MURAL OR ART CABLE SYSTEMS, AND ANY OTHER WALL
MOUNTED OBJECT.
UNLESS NOTED OTHERWISE, ALL EXPOSED STRUCTURAL
STEEL TO BE PAINTED PA-1.
ALL DOOR AND FRAMES TO BE PA-2.
ALL METAL FABRICATIONS TO BE PA-2.
INTERIOR CAULKING TO MATCH ADJACENT WALL FINISH COLOR.
ALL EXPOSED CONCRETE FLOORS SHALL BE SEALED.
WALL CORNER GUARDS TO BE INSTALLED STARTING AT THE
TOP OF THE SCHEDULED WALL BASE.
AT GYPSUM BOARD SOFFITS AND BULKHEADS, PAINT ALL
EXPOSED SURFACES.
PAINT ALL EXPOSED STRUCTURAL STEEL ELEMENTS,
MISCELLANEOUS STEEL, PIPING, HANGERS, VALVES AND
CONDUITS. THE PAINT COLOR SHALL BE AS INDICATED
ON SCHEDULE. ALL FIRE PROTECTION PIPING COLOR SHALL
BE SAFETY RED.
ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND
ASSOCIATED SUPPORTING EQUIPMENT TO BE PAINTED
PA-1 UNLESS OTHERWISE REQUIRED BY CODE.
COORDINATE WITH MECHANICAL / ELECTRICAL FOR FINISHES
ON MECHANICAL OR ELECTRICAL EQUIPMENT.
DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL
SURFACES, OPERATING PARTS, LABELS OR WARNINGS.
REFER TO AND COORDINATE WITH FURNITURE DRAWINGS
AND TYPICAL MOUNTING HEIGHTS DRAWING FOR WALL
MOUNTING HEIGHTS OF FF&E.
REFER TO FINISH SCHEDULE COLOR SCHEDULE FOR INTERIOR FINISH
MATERIALS. BASIS OF DESIGN OR EQUIVALENT COLOR AND FINISH
CODES ARE AS INDICATED ON THE ROOM FINISH SCHEDULE.
GENERAL SIGNAGE SCHEDULE NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
REFER TO SIGNAGE PLACEMENT DRAWINGS FOR LOCATION
OF INTERIOR SIGNS.
REFER TO SIGNAGE DETAILS FOR SIGNAGE CONSTRUCTION
AND MOUNTING ELEVATION.
REFER TO ARCHITECTURAL DRAWINGS FOR COORDINATION
OF SIGNAGE INSTALLATION TO WALL CONSTRUCTION.
SIGNAGE MUST BE ANCHORED THRU THE SURFACE APPLIED
WALL FINISHES TO THE SUBSTRATE WALL.
ALL HARDWARE/MOUNTING ATTACHMENTS TO BE CONCEALED
AND APPROPRIATE FOR THE RECEIVING BUILDING SURFACE.
ALL SIGNAGE SHALL COMPLY WITH THE MOST CURRENT
VERSION OF THE ARCHITECTURAL BARRIERS ACT ACCESSIBILITY
STANDARDS (ABAAS).
ALL SIGNAGE MOUNTED ON GLASS SHALL HAVE A MATCHING
BACK PLATE TO CONCEAL ATTACHMENT METHOD OF SIGN.
INSTALL FIRE EXTINGUISHER IDENTIFICATION SIGN ABOVE ALL
FIRE EXTINGUISHER CABINETS AND WALL BRACKET MOUNTED
EXTINGUISHERS. SEE LIFE SAFETY PLANS FOR FIRE
EXTINGUISHER LOCATIONS.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING WITH SIGNAGE MANUFACTURER(S) TO
PROVIDE ANY ADDITIONAL SIGNAGE AS REQUIRED BY
GOVERNING MUNICIPALITY AT THE SITE LOCATION.
ALL MESSAGE TEXT AS SHOWN ON THE SIGN SCHEDULE IS A
PLACE HOLDER ONLY AND IS NOT THE FINAL TEXT MESSAGE.
ALL MESSAGE TEXT SHALL BE CONFIRMED BY GOVERNMENT
END USER PRIOR TO SIGNAGE SHOP DRAWINGS. ALLOW FOR
MAXIMUM 4 DIGIT ROOM NUMBERS AND MINIMUM 25
CHARACTER ROOM NAMES TYPICAL FOR ALL SIGNS.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
OBTAINING LOGO IMAGES FROM APPROVED GOVERNMENT
REPRESENTATIVE AND PROVIDING TO SIGNAGE
MANUFACTURER(S). SIGNAGE MANUFACTURER(S) SHALL BE
RESPONSIBLE FOR CREATING VECTOR IMAGES FOR
INCORPORATION INTO SIGNAGE BACKGROUND INSERTS AND
LOGO MEDALLION SIGNAGE.
PROVIDE MESSAGE INSERTS FOR WINDOW SIGNS WHERE
INDICATED IN THE SIGNAGE DRAWINGS OR SPECIFICATIONS.
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
K
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
P N
SHEET ID
C E
R T
IF
IE
D F
IN
A
L
2 864 10
E
F
G
/8
A-701
S B
G A
S B
/2
/2
Z H
T V
W P
A F
B X
T A
L
Z H
T V
W P
A F
B X
T A
L R
E N
O V
A T
IO
N
R O
O M
F
IN
IS
H
S C
H E
D U
L E
F
IN
IS
H L
E G
E N
D
A N
D S
IG
N
A G
E S
C H
E D
U L E
W R
IG
H
T -P
A T
T E
R S
O N
A F
B
O H
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR
BASE WALLS
CEILING
REMARKSMATERIAL HEIGHT NORTH EAST SOUTH WEST
FIRST FLOOR
118 OFFICE (EXIST) EXISTING RB-1 RB-1 EXISTING EXISTING EXISTING PA-1 EXISTING
119 MECHANICAL ROOM CH-1 - - PA-1 PA-1 PA-1 PA-1 OPEN TO STRUCTURE
121 As MBE LAB RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
121A MBE SUPPORT RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 OPEN TO STRUCTURE
122 NEXT GEN MBE LAB RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
123 STRUCTURAL CHARACTERIZATION RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
124 SURFACE SCIENCE EAST RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
148 GOWNING ROOM SV-1 Integral Base 4" CRPS-1 CRPS-1 CRPS-1 CRPS-1 CRCS-1
148A ANTEROOM SV-1 Integral Base 4" CRPS-1 CRPS-1 CRPS-1 CRPS-1 CRCS-1
148B ETCH & DEP BAY SV-1 Integral Base 4" CRPS-1 / CRPS-2 CRPS-1 CRPS-1 CRPS-1 CRCS-1
148C ETCH & DEP SUPPORT SV-1 Integral Base 4" CRPS-1 CRPS-1 / PE-1 CRPS-1 CRPS-1 CRCS-1
149 LITHO BAY SV-1 Integral Base 4" CRPS-1 CRPS-1 CRPS-1 CRPS-1 / CRPS-2 CRCS-1
149A LITHO SUPPORT ROOM SV-1 Integral Base 4" CRPS-1 / PE-1 CRPS-1 / PE-1 CRPS-1 / PE-1 CRPS-1 / PE-1 OPEN TO STRUCTURE
150 LITHO PREP BAY SV-1 Integral Base 4" CRPS-1 CRPS-1 CRPS-1 CRPS-1 / CRPS-2 CRCS-1
151 SEM ROOM RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
152 SURFACE SCIENCE WEST RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
152A SURFACE SCIENCE SUPPORT RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1
156 EAST CORRIDOR EXISTING EXISTING - PA-1 PA-1 PA-1 PA-1 ACT-1 MATCH SOUTH CORRIDORS
158 WEST CORRIDOR EXISTING EXISTING - PA-1 PA-1 PA-1 PA-1 ACT-1 MATCH SOUTH CORRIDORS
160 VESTIBULE WOM-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1 MATCH SOUTH CORRIDORS / ALUMINUM STOREFRONT
UC09 UTILITY CORE (EXIST) - - - - - - - OPEN TO STRUCTURE
UC10 UTILITY CORE (EXIST) - - - - - - - OPEN TO STRUCTURE
UC11 UTILITY CORE (EXIST) - - - - - - - OPEN TO STRUCTURE
FINISH LEGEND - BASIS OF DESIGN OR EQUIVALENT
MATERIAL DESCRIPTION MANUF. MODEL NUMBER PRODUCT NUMBER COLOR REMARKS
CEILINGS
ACT-1 24" x 24" / CLEANROOM / 15/16" CLEANROOM GRID ARMSTRONG CLEAN ROOM FL 1715 WHITE WITH GRAY SPATTER (WG) NON-SHEDDING
CRCS-1 CLEANROOM CEILING SYSTEM PORTAFAB 2" GASKETED CEILING GRID WITH FFU'S FFU'S & BLANKING PANELS OR CLEANROOM ACOUSTIC TILE - ISO 6
CRCS-2 CLEANROOM CEILING SYSTEM PORTAFAB 2" GASKETED CEILING GRID WITH FFU'S FFU'S & ANODIZED ALUMINUM BLANK-OFF PANELS - ISO 5
FLOORING
CH-1 CONCRETE SEALED - - - -
RF-1 12" X 12" RESILIENT TILE (VCT) ARMSTRONG - 51904 STERLING
SV-1 PVC-FREE HOMOGENEOUS SHEET FLOORING ARMSTRONG MEDINPURE WITH DIAMOND 10 TECHNOLOGY H6004 MIRROR LAKE
WOM-1 24" X 24" WALK OFF MAT SHAW CONTRACT PORTAL TILE 5T035 MULTICOLOR 34481
MISCELLANEOUS
CG-1 CORNER GUARD KOROSEAL - GS15 STAINLESS STEEL
RB-1 RUBBER BASE ROPPE PINNACLE/TS/1/8" 100 BLACK 4"
WALLS
CRPS-1 CLEANROOM PARTITION SYSTEM PORTAFAB S3000 - CLEAR ANODIZED ALUMINUM
CRPS-2 CLEANROOM PARTITION SYSTEM PORTAFAB FABLINE FURRING 250 - CLEAR ANODIZED ALUMINUM
PA-1 ACRYLIC/LATEX SHERWIN WILLIAMS - SW7070 SITE WHITE FIELD PAINT
PA-2 ACRYLIC/LATEX SHERWIN WILLIAMS - SW6228 REFUGE BLUE DOORS AND FRAMES
PA-3 ACRYLIC/LATEX SHERWIN WILLIAMS - SW7007 CEILING BRIGHT WHITE HARD CEILING/BULKHEADS
PE-1 EPOXY SHERWIN WILLIAMS - SW7070 SITE WHITE RETURN AIR CHASES
PE-2 EPOXY SHERWIN WILLIAMS INDUSTRIAL PRO INDUSTRIAL PRE-CATALYZED
WATERBASED EPOXY
COLOR MATCH SW6228 REFUGE BLUE STEEL DOORS AND FRAMES
SIGNAGE SCHEDULE
TAG SIGN TYPE SIGN NUMBER MESSAGE TEXT REMARKS
S101 B 119 MECHANICAL ROOM
S102 A 121 III/V MBE LAB
S103 B 121A UTILITY
S104 A 122 OXIDE MBE LAB
S105 A 123 STRUCTURAL CHARACTERIZATION
S106 A 124 SURFACE SCIENCE
S107 B 152A UTILITY
S108 B 152A UTILITY
S109 A 152 SURFACE SCIENCE
S110 A 151 SEM LAB
S111 A 150 LITHO PREP BAY
S112 B 149A UTILITY
S113 B 148C UTILITY
S114 A 148 GOWNING
S115 B 119 MECHANICAL ROOM
* REFER TO AFRL / RX STANDARDS FOR FINAL SIGNAGE DESIGN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
M A
Y
F23B-F2
10.25"W X 10.5"HTYPE 0.2
12"W X 25"H
T O
3"
BASE LINE OF HIGHEST COPY MOUNTED
NO HIGHER THAN 60" AFF
BASELINE OF LOWEST COPY MOUNTED
NO LOWER THAN 48" AFF
MOUNT SIGN ON LATCH SIDE OF DOOR
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
P N
SHEET ID
C E
R T
IF
IE
D F
IN
A
L
2 864 10
E
F
G
A s i n d ic a te d
A-702
S B
G A
S B
/2
/2
Z H
T V
W P
A F
B X
T A
L
Z H
T V
W P
A F
B X
T A
L R
E N
O V
A T
IO
N
S
IG
N A
G E
D E
T A
IL
S
W R
IG
H
T -P
A T
T E
R S
O N
A F
B
O H
SCALE: 1" = 1'-0"A6
Sign Type - B
SCALE: 1" = 1'-0"A4
SIGN TYPE - A
SCALE: 3/4" = 1'-0"A1
TYPICAL INTERIOR SIGN INSTALLATION - WALL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
M A
Y
GENERAL WALL FINISH PLAN NOTES:
1.
2.
REFER TO ROOM FINISH SCHEDULE GENERAL NOTES.
REFER TO ROOM FINISH SCHEDULE FOR ADDITIONAL
INTERIOR FINISH PLACEMENTS.
1 2 3 4 5
6 7
B
C
D
E
MECHANICAL ROOM
VESTIBULE
EAST CORRIDOR
NEXT GEN MBE LAB
As MBE LAB
SURFACE SCIENCE
SUPPORT
152A
MBE SUPPORT
121A
WEST CORRIDOR
LITHO PREP BAY
LITHO SUPPORT
ROOM
149A
UTILITY CORE (EXIST)
UC10
UTILITY CORE (EXIST)
UC09
ETCH & DEP BAY
148B
LITHO BAY
GOWNING ROOM
UTILITY CORE (EXIST)
UC11
STRUCTURAL
CHARACTERIZATION
SURFACE SCIENCE
EAST
ETCH & DEP
SUPPORT
148C
SEM ROOM
SURFACE SCIENCE
WEST
CH-1
EXISTING
RF-1 RF-1 RF-1 RF-1
RF-1
EXISTING
RF-1SV-1
SV-1CH-1
S101
S102 S104 S105 S106
S107
S108
S109S110S111S114S115
S103
S112
S113
CG
CG
CG
CG
CG
CG
EXISTING
WOM-1
EXISTING EXISTING EXISTING EXISTING
EXISTINGEXISTINGEXISTINGEXISTING
CH-1
EXISTING
RF-1
EXISTING
SV-1
CH-1
RF-1
EXISTING
RF-1
EXISTING
SV-1
SV-1
RF-1
EXISTING
RF-1
EXISTING
RF-1RF-1
CGCG
GENERAL SIGNAGE PLACEMENT PLAN NOTES:
1.
2.
3.
4.
5.
REFER TO SIGNAGE SCHEDULE GENERAL NOTES.
REFER TO SIGNAGE SCHEDULE AND DETAIL DRAWINGS FOR
ADDITIONAL INFORMATION.
REFER TO SIGNAGE SCHEDULE FOR SIGN LOCATION TAG, DOOR
LOCATION, SIGN TYPE, SIGN TEXT NUMBER, AND PLACEHOLDER
MESSAGE TEXT.
REFER TO SIGNAGE MOUNTING HEIGHTS ON SIGNAGE DETAIL
DRAWINGS. SIGNS TO BE WALL-MOUNTED ON THE LATCH SIDE
OF DOOR OR AS INDICATED. HEIGHTS, CLEARANCES, AND
CONFIGURATIONS SHOWN ARE TYPICAL AND SHALL APPLY IN
ALL INSTANCES UNLESS NOTED OTHERWISE.
INTERIOR SIGNAGE SHALL COMPLY WITH AFRL/RX STANDARDS.
GENERAL FLOOR FINISH PLAN NOTES:
1.
2.
3.
REFER TO ROOM FINISH SCHEDULE GENERAL NOTES.
REFER TO ROOM FINISH SCHEDULE FOR FLOOR FINISHES
NOT INDICATED ON PLANS.
FOR FLOORING MATERIAL TRANSITIONS WHICH OCCUR AT
DOORWAYS, TERMINATE FINISH TRANSITION AND TRANSITION
STRIP UNDER THE DOOR AT THE DOOR STOP OR CENTER
UNDER THE CLOSED DOOR.
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MEN'S TOILET
JANITOR
VESTIBULE
ELEC
STAIR #1
HYDR. ELEV.
WOMEN'S TOILET
CLOSET
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONFERENCE ROOM
ELEC. ELEV.
CORRIDOR
STAIR #2
S2
STAIR #3
S3
FACE OF FLOOR SLAB
COVE STICK
SHEET VINYL & INTEGRAL
BASE
CAULK TO SEAL
3/8" RADIUS BASE COVE
SCHEDULED PARTITION -
RE: PLANS
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
A B
KEY PLAN
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
LOUISVILLE DISTRICT
P N
SHEET ID
C E
R T
IF
IE
D F
IN
A
L
2 864 10
E
F
G
N.T.S.
NORTH
A s i n d ic a te d
A-703
S B
G A
S B
/2
/2
Z H
T V
W P
A F
B X
T A
L
Z H
T V
W P
A F
B X
T A
L R
E N
O V
A T
IO
N
F
IR
S T
F L O
O R
F
IN
IS
H
A N
D S
IG
N
A G
E P
L A
N
A R
E A
A
W R
IG
H
T -P
A T
T E
R S
O N
A F
B
O H
SCALE: 1/8" = 1'-0"A1
FIRST FLOOR FINISH AND SIGNAGE PLAN - AREA A
SCALE IN FEET
0 4' 8' 16'
NORTH
SCALE: 6" = 1'-0"C8
INTEGRAL BASE DETAIL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L
M A
Y
File details come from the government source that posted it. Updated .