This document package includes a solicitation for a federal construction contract opportunity and related project files. The solicitation is for lab renovations for the XTAL Building 654 at Wright-Patterson Air Force Base, OH, with an estimated construction cost between $5-10 million. The NAICS code is 236220, with a size standard of $39.5 million. The solicitation requires compliance with CCR/ORCA requirements through SAM and adherence to the HUBZone 10% price evaluation preference. An organized site visit is scheduled for July 1, 2021 at 9 AM ET, with an RSVP deadline of June 28, 2021. The related project files provide design and construction details, including room finish schedules, signage schedules, and plans showing wall finishes, floor finishes, and signage placements.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation For XTAL Renovations Project Bldg 654 Wright-Patterson AFB, OH

P2: 487666

Design Bid Build

SID

Certified Final Design Submittal

23 June 2021

W912QR21R0051

ARIMS: 200A

Disposition: Maintain for 15yrs after construction

W912QR21R0051-0000

P2#487666 XTAL Renovation Project CERTIFIED FINAL DESIGN SUBMITTAL Wright-Patterson AFB, OH

THIS PAGE INTENTIONALLY LEFT BLANK

XTAL RENOVATION PROJECT

WRIGHT-PATTERSON AFB, OH

RTA DESIGN SUBMITTAL

STRUCTURAL INTERIOR DESIGN (SID)

MAY 2021

XT

A

L R en ov at io n P ro je ct W rig ht

P at te rs on , A

FB

, O

H

TABLE OF CONTENTS:

FLOOR FINISHES

WALL FINISHES

CEILING FINISHES

MISC. FINISHES

DRAWINGS

L R en ov at io n P ro je ct W rig ht

P at te rs on , A

FB

, O

H

FLOOR FINISHES

RF-1

DESCRIPTION: 12” x 12” RESILIENT TILE

MANUFACTURER: ARMSTRONG

PRODUCT / STYLE: VCT

COLOR: 51904 STERLING SILVER

SV-1

DESCRIPTION: PCV-FREE HEMOGENEOUS

SHEET FLOORING

MANUFACTURER: ARMSTRONG

PRODUCT / STYLE: MEDINPURE WITH DIA-

MOND 10 TECHNOLOGY

COLOR: MIRROR LAKE H6004

WOM-1

DESCRIPTION: 24” X 24” WALK OFF MAT

MANUFACTURER: SHAW CONTRACT

PRODUCT / STYLE: PORTAL TILE 5T035

COLOR: MULTICOLOR 34481

L R en ov at io n P ro je ct W rig ht

P at te rs on , A

FB

, O

H

WALL FINISHES

PA-1 / PE-1

DESCRIPTION: PAINT

MANUFACTURER: SHERWIN WILLIAMS

PRODUCT / STYLE: ACRYLIC, LATEX / EPOXY

COLOR: SW7070 SITE WHITE

PA-2 / PE-2

DESCRIPTION: PAINT

MANUFACTURER: SHERWIN WILLIAMS

PRODUCT / STYLE: ACRYLIC, LATEX / EPOXY

COLOR: SW6228 REFUGE

PA-3

DESCRIPTION: PAINT

MANUFACTURER: SHERWIN WILLIAMS

PRODUCT / STYLE: ACRYLIC / LATEX

COLOR: SW7007 CEILING BRIGHT WHITE

L R en ov at io n P ro je ct W rig ht

P at te rs on , A

FB

, O

H

CEILING FINISHES

ACT-1

DESCRIPTION: 24” X 24” ACOUSTICAL CEILING TILE

MANUFACTURER: ARMSTRONG

PRODUCT / STYLE: CLEAN ROOM FL, 15/16” CLEANROOM GRID

COLOR: WHITE WITH GRAY SPATTER

L R en ov at io n P ro je ct W rig ht

P at te rs on , A

FB

, O

H

MISC. FINISHES

CG-1

DESCRIPTION: CORNER GUARD

MANUFACTURER: KOROSEAL

PRODUCT / STYLE: GS15

COLOR: STAINLESS STEEL

RB-1

DESCRIPTION: 4” RUBBER BASE

MANUFACTURER: ROPPE

PRODUCT / STYLE: PINNACLE TS / 1/8”

COLOR: 100 BLACK

DRAWINGS

XTAL RENOVATION PROJECT

WRIGHT PATTERSON, AFB, OH MAY 2021

GENERAL ROOM FINISH SCHEDULE NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

REFER TO SPECIFICATIONS FOR THE BASIS OF DESIGN OR

EQUIVALENT MANUFACTURER TECHNICAL REQUIREMENTS.

REFER TO INTERIOR ELEVATIONS, REFLECTED

CEILING DRAWINGS, FLOOR FINISH DRAWINGS, WALL FINISH

DRAWINGS, ENLARGED PLAN DRAWINGS AND INTERIOR DETAIL

DRAWINGS FOR ADDITIONAL FINISH PLACEMENT INFORMATION.

REFER TO ELECTRICAL DRAWINGS, MECHANICAL DRAWINGS,

STRUCTURAL DRAWINGS AND COMMUNICATION DRAWINGS

FOR COORDINATION OF BUILDING FINISHES TO BUILDING

SYSTEMS.

REFER TO FLOOR FINISH DRAWINGS FOR PLACEMENT OF

FLOOR FINISHES, FLOOR PATTERNS AND FLOOR MATERIAL

CHANGES. REFER TO FLOORING TRANSITION DETAILS FOR

TRANSITIONS BETWEEN ADJOINING FLOORING MATERIALS.

REFER TO WALL FINISH DRAWINGS AND INTERIOR ELEVATIONS

FOR WALL FINISH EXTENTS, CORNER GUARD LOCATIONS,

SIGNAGE, ART AND SPECIALTY WALL FINISH LOCATIONS.

REFER TO REFLECTED CEILING DRAWINGS FOR CEILING

HEIGHTS AND CEILING MATERIAL EXTENTS.

PROVIDE BLOCKING AS REQUIRED TO SECURE ALL WALL

MOUNTED ITEMS INCLUDING TOILET FIXTURES, TOILET

ACCESSORIES, TOILET PARTITIONS, MILLWORK, SHELVES,

COUNTERTOP SUPPORTS, MARKERBOARDS, TACKBOARDS,

FLAT PANEL DISPLAYS, CAMERAS, ACOUSTICAL WALL PANELS,

MURAL OR ART CABLE SYSTEMS, AND ANY OTHER WALL

MOUNTED OBJECT.

UNLESS NOTED OTHERWISE, ALL EXPOSED STRUCTURAL

STEEL TO BE PAINTED PA-1.

ALL DOOR AND FRAMES TO BE PA-2.

ALL METAL FABRICATIONS TO BE PA-2.

INTERIOR CAULKING TO MATCH ADJACENT WALL FINISH COLOR.

ALL EXPOSED CONCRETE FLOORS SHALL BE SEALED.

WALL CORNER GUARDS TO BE INSTALLED STARTING AT THE

TOP OF THE SCHEDULED WALL BASE.

AT GYPSUM BOARD SOFFITS AND BULKHEADS, PAINT ALL

EXPOSED SURFACES.

PAINT ALL EXPOSED STRUCTURAL STEEL ELEMENTS,

MISCELLANEOUS STEEL, PIPING, HANGERS, VALVES AND

CONDUITS. THE PAINT COLOR SHALL BE AS INDICATED

ON SCHEDULE. ALL FIRE PROTECTION PIPING COLOR SHALL

BE SAFETY RED.

ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND

ASSOCIATED SUPPORTING EQUIPMENT TO BE PAINTED

PA-1 UNLESS OTHERWISE REQUIRED BY CODE.

COORDINATE WITH MECHANICAL / ELECTRICAL FOR FINISHES

ON MECHANICAL OR ELECTRICAL EQUIPMENT.

DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL

SURFACES, OPERATING PARTS, LABELS OR WARNINGS.

REFER TO AND COORDINATE WITH FURNITURE DRAWINGS

AND TYPICAL MOUNTING HEIGHTS DRAWING FOR WALL

MOUNTING HEIGHTS OF FF&E.

REFER TO FINISH SCHEDULE COLOR SCHEDULE FOR INTERIOR FINISH

MATERIALS. BASIS OF DESIGN OR EQUIVALENT COLOR AND FINISH

CODES ARE AS INDICATED ON THE ROOM FINISH SCHEDULE.

GENERAL SIGNAGE SCHEDULE NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

REFER TO SIGNAGE PLACEMENT DRAWINGS FOR LOCATION

OF INTERIOR SIGNS.

REFER TO SIGNAGE DETAILS FOR SIGNAGE CONSTRUCTION

AND MOUNTING ELEVATION.

REFER TO ARCHITECTURAL DRAWINGS FOR COORDINATION

OF SIGNAGE INSTALLATION TO WALL CONSTRUCTION.

SIGNAGE MUST BE ANCHORED THRU THE SURFACE APPLIED

WALL FINISHES TO THE SUBSTRATE WALL.

ALL HARDWARE/MOUNTING ATTACHMENTS TO BE CONCEALED

AND APPROPRIATE FOR THE RECEIVING BUILDING SURFACE.

ALL SIGNAGE SHALL COMPLY WITH THE MOST CURRENT

VERSION OF THE ARCHITECTURAL BARRIERS ACT ACCESSIBILITY

STANDARDS (ABAAS).

ALL SIGNAGE MOUNTED ON GLASS SHALL HAVE A MATCHING

BACK PLATE TO CONCEAL ATTACHMENT METHOD OF SIGN.

INSTALL FIRE EXTINGUISHER IDENTIFICATION SIGN ABOVE ALL

FIRE EXTINGUISHER CABINETS AND WALL BRACKET MOUNTED

EXTINGUISHERS. SEE LIFE SAFETY PLANS FOR FIRE

EXTINGUISHER LOCATIONS.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR

COORDINATING WITH SIGNAGE MANUFACTURER(S) TO

PROVIDE ANY ADDITIONAL SIGNAGE AS REQUIRED BY

GOVERNING MUNICIPALITY AT THE SITE LOCATION.

ALL MESSAGE TEXT AS SHOWN ON THE SIGN SCHEDULE IS A

PLACE HOLDER ONLY AND IS NOT THE FINAL TEXT MESSAGE.

ALL MESSAGE TEXT SHALL BE CONFIRMED BY GOVERNMENT

END USER PRIOR TO SIGNAGE SHOP DRAWINGS. ALLOW FOR

MAXIMUM 4 DIGIT ROOM NUMBERS AND MINIMUM 25

CHARACTER ROOM NAMES TYPICAL FOR ALL SIGNS.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR

OBTAINING LOGO IMAGES FROM APPROVED GOVERNMENT

REPRESENTATIVE AND PROVIDING TO SIGNAGE

MANUFACTURER(S). SIGNAGE MANUFACTURER(S) SHALL BE

RESPONSIBLE FOR CREATING VECTOR IMAGES FOR

INCORPORATION INTO SIGNAGE BACKGROUND INSERTS AND

LOGO MEDALLION SIGNAGE.

PROVIDE MESSAGE INSERTS FOR WINDOW SIGNS WHERE

INDICATED IN THE SIGNAGE DRAWINGS OR SPECIFICATIONS.

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

K

N

S A

S C

IT

Y

D

IS

T R

IC

T

E

T

H S

T R

E E

T K

A N

S A

S C

IT

Y

M

O

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

P N

SHEET ID

C E

R T

IF

IE

D F

IN

A

L

2 864 10

E

F

G

/8

A-701

S B

G A

S B

/2

/2

Z H

T V

W P

A F

B X

T A

L

Z H

T V

W P

A F

B X

T A

L R

E N

O V

A T

IO

N

R O

O M

F

IN

IS

H

S C

H E

D U

L E

F

IN

IS

H L

E G

E N

D

A N

D S

IG

N

A G

E S

C H

E D

U L E

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

ROOM FINISH SCHEDULE

ROOM

NUMBER ROOM NAME FLOOR

BASE WALLS

CEILING

REMARKSMATERIAL HEIGHT NORTH EAST SOUTH WEST

FIRST FLOOR

118 OFFICE (EXIST) EXISTING RB-1 RB-1 EXISTING EXISTING EXISTING PA-1 EXISTING

119 MECHANICAL ROOM CH-1 - - PA-1 PA-1 PA-1 PA-1 OPEN TO STRUCTURE

121 As MBE LAB RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1

121A MBE SUPPORT RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 OPEN TO STRUCTURE

122 NEXT GEN MBE LAB RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1

123 STRUCTURAL CHARACTERIZATION RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1

124 SURFACE SCIENCE EAST RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1

148 GOWNING ROOM SV-1 Integral Base 4" CRPS-1 CRPS-1 CRPS-1 CRPS-1 CRCS-1

148A ANTEROOM SV-1 Integral Base 4" CRPS-1 CRPS-1 CRPS-1 CRPS-1 CRCS-1

148B ETCH & DEP BAY SV-1 Integral Base 4" CRPS-1 / CRPS-2 CRPS-1 CRPS-1 CRPS-1 CRCS-1

148C ETCH & DEP SUPPORT SV-1 Integral Base 4" CRPS-1 CRPS-1 / PE-1 CRPS-1 CRPS-1 CRCS-1

149 LITHO BAY SV-1 Integral Base 4" CRPS-1 CRPS-1 CRPS-1 CRPS-1 / CRPS-2 CRCS-1

149A LITHO SUPPORT ROOM SV-1 Integral Base 4" CRPS-1 / PE-1 CRPS-1 / PE-1 CRPS-1 / PE-1 CRPS-1 / PE-1 OPEN TO STRUCTURE

150 LITHO PREP BAY SV-1 Integral Base 4" CRPS-1 CRPS-1 CRPS-1 CRPS-1 / CRPS-2 CRCS-1

151 SEM ROOM RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1

152 SURFACE SCIENCE WEST RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1

152A SURFACE SCIENCE SUPPORT RF-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1

156 EAST CORRIDOR EXISTING EXISTING - PA-1 PA-1 PA-1 PA-1 ACT-1 MATCH SOUTH CORRIDORS

158 WEST CORRIDOR EXISTING EXISTING - PA-1 PA-1 PA-1 PA-1 ACT-1 MATCH SOUTH CORRIDORS

160 VESTIBULE WOM-1 RB-1 4" PA-1 PA-1 PA-1 PA-1 ACT-1 MATCH SOUTH CORRIDORS / ALUMINUM STOREFRONT

UC09 UTILITY CORE (EXIST) - - - - - - - OPEN TO STRUCTURE

UC10 UTILITY CORE (EXIST) - - - - - - - OPEN TO STRUCTURE

UC11 UTILITY CORE (EXIST) - - - - - - - OPEN TO STRUCTURE

FINISH LEGEND - BASIS OF DESIGN OR EQUIVALENT

MATERIAL DESCRIPTION MANUF. MODEL NUMBER PRODUCT NUMBER COLOR REMARKS

CEILINGS

ACT-1 24" x 24" / CLEANROOM / 15/16" CLEANROOM GRID ARMSTRONG CLEAN ROOM FL 1715 WHITE WITH GRAY SPATTER (WG) NON-SHEDDING

CRCS-1 CLEANROOM CEILING SYSTEM PORTAFAB 2" GASKETED CEILING GRID WITH FFU'S FFU'S & BLANKING PANELS OR CLEANROOM ACOUSTIC TILE - ISO 6

CRCS-2 CLEANROOM CEILING SYSTEM PORTAFAB 2" GASKETED CEILING GRID WITH FFU'S FFU'S & ANODIZED ALUMINUM BLANK-OFF PANELS - ISO 5

FLOORING

CH-1 CONCRETE SEALED - - - -

RF-1 12" X 12" RESILIENT TILE (VCT) ARMSTRONG - 51904 STERLING

SV-1 PVC-FREE HOMOGENEOUS SHEET FLOORING ARMSTRONG MEDINPURE WITH DIAMOND 10 TECHNOLOGY H6004 MIRROR LAKE

WOM-1 24" X 24" WALK OFF MAT SHAW CONTRACT PORTAL TILE 5T035 MULTICOLOR 34481

MISCELLANEOUS

CG-1 CORNER GUARD KOROSEAL - GS15 STAINLESS STEEL

RB-1 RUBBER BASE ROPPE PINNACLE/TS/1/8" 100 BLACK 4"

WALLS

CRPS-1 CLEANROOM PARTITION SYSTEM PORTAFAB S3000 - CLEAR ANODIZED ALUMINUM

CRPS-2 CLEANROOM PARTITION SYSTEM PORTAFAB FABLINE FURRING 250 - CLEAR ANODIZED ALUMINUM

PA-1 ACRYLIC/LATEX SHERWIN WILLIAMS - SW7070 SITE WHITE FIELD PAINT

PA-2 ACRYLIC/LATEX SHERWIN WILLIAMS - SW6228 REFUGE BLUE DOORS AND FRAMES

PA-3 ACRYLIC/LATEX SHERWIN WILLIAMS - SW7007 CEILING BRIGHT WHITE HARD CEILING/BULKHEADS

PE-1 EPOXY SHERWIN WILLIAMS - SW7070 SITE WHITE RETURN AIR CHASES

PE-2 EPOXY SHERWIN WILLIAMS INDUSTRIAL PRO INDUSTRIAL PRE-CATALYZED

WATERBASED EPOXY

COLOR MATCH SW6228 REFUGE BLUE STEEL DOORS AND FRAMES

SIGNAGE SCHEDULE

TAG SIGN TYPE SIGN NUMBER MESSAGE TEXT REMARKS

S101 B 119 MECHANICAL ROOM

S102 A 121 III/V MBE LAB

S103 B 121A UTILITY

S104 A 122 OXIDE MBE LAB

S105 A 123 STRUCTURAL CHARACTERIZATION

S106 A 124 SURFACE SCIENCE

S107 B 152A UTILITY

S108 B 152A UTILITY

S109 A 152 SURFACE SCIENCE

S110 A 151 SEM LAB

S111 A 150 LITHO PREP BAY

S112 B 149A UTILITY

S113 B 148C UTILITY

S114 A 148 GOWNING

S115 B 119 MECHANICAL ROOM

* REFER TO AFRL / RX STANDARDS FOR FINAL SIGNAGE DESIGN

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L

M A

Y

F23B-F2

10.25"W X 10.5"HTYPE 0.2

12"W X 25"H

T O

3"

BASE LINE OF HIGHEST COPY MOUNTED

NO HIGHER THAN 60" AFF

BASELINE OF LOWEST COPY MOUNTED

NO LOWER THAN 48" AFF

MOUNT SIGN ON LATCH SIDE OF DOOR

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

N

S A

S C

IT

Y

D

IS

T R

IC

T

E

T

H S

T R

E E

T K

A N

S A

S C

IT

Y

M

O

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

P N

SHEET ID

C E

R T

IF

IE

D F

IN

A

L

2 864 10

E

F

G

A s i n d ic a te d

A-702

S B

G A

S B

/2

/2

Z H

T V

W P

A F

B X

T A

L

Z H

T V

W P

A F

B X

T A

L R

E N

O V

A T

IO

N

S

IG

N A

G E

D E

T A

IL

S

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

SCALE: 1" = 1'-0"A6

Sign Type - B

SCALE: 1" = 1'-0"A4

SIGN TYPE - A

SCALE: 3/4" = 1'-0"A1

TYPICAL INTERIOR SIGN INSTALLATION - WALL

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L

M A

Y

GENERAL WALL FINISH PLAN NOTES:

1.

2.

REFER TO ROOM FINISH SCHEDULE GENERAL NOTES.

REFER TO ROOM FINISH SCHEDULE FOR ADDITIONAL

INTERIOR FINISH PLACEMENTS.

1 2 3 4 5

6 7

B

C

D

E

MECHANICAL ROOM

VESTIBULE

EAST CORRIDOR

NEXT GEN MBE LAB

As MBE LAB

SURFACE SCIENCE

SUPPORT

152A

MBE SUPPORT

121A

WEST CORRIDOR

LITHO PREP BAY

LITHO SUPPORT

ROOM

149A

UTILITY CORE (EXIST)

UC10

UTILITY CORE (EXIST)

UC09

ETCH & DEP BAY

148B

LITHO BAY

GOWNING ROOM

UTILITY CORE (EXIST)

UC11

STRUCTURAL

CHARACTERIZATION

SURFACE SCIENCE

EAST

ETCH & DEP

SUPPORT

148C

SEM ROOM

SURFACE SCIENCE

WEST

CH-1

EXISTING

RF-1 RF-1 RF-1 RF-1

RF-1

EXISTING

RF-1SV-1

SV-1CH-1

S101

S102 S104 S105 S106

S107

S108

S109S110S111S114S115

S103

S112

S113

CG

CG

CG

CG

CG

CG

EXISTING

WOM-1

EXISTING EXISTING EXISTING EXISTING

EXISTINGEXISTINGEXISTINGEXISTING

CH-1

EXISTING

RF-1

EXISTING

SV-1

CH-1

RF-1

EXISTING

RF-1

EXISTING

SV-1

SV-1

RF-1

EXISTING

RF-1

EXISTING

RF-1RF-1

CGCG

GENERAL SIGNAGE PLACEMENT PLAN NOTES:

1.

2.

3.

4.

5.

REFER TO SIGNAGE SCHEDULE GENERAL NOTES.

REFER TO SIGNAGE SCHEDULE AND DETAIL DRAWINGS FOR

ADDITIONAL INFORMATION.

REFER TO SIGNAGE SCHEDULE FOR SIGN LOCATION TAG, DOOR

LOCATION, SIGN TYPE, SIGN TEXT NUMBER, AND PLACEHOLDER

MESSAGE TEXT.

REFER TO SIGNAGE MOUNTING HEIGHTS ON SIGNAGE DETAIL

DRAWINGS. SIGNS TO BE WALL-MOUNTED ON THE LATCH SIDE

OF DOOR OR AS INDICATED. HEIGHTS, CLEARANCES, AND

CONFIGURATIONS SHOWN ARE TYPICAL AND SHALL APPLY IN

ALL INSTANCES UNLESS NOTED OTHERWISE.

INTERIOR SIGNAGE SHALL COMPLY WITH AFRL/RX STANDARDS.

GENERAL FLOOR FINISH PLAN NOTES:

1.

2.

3.

REFER TO ROOM FINISH SCHEDULE GENERAL NOTES.

REFER TO ROOM FINISH SCHEDULE FOR FLOOR FINISHES

NOT INDICATED ON PLANS.

FOR FLOORING MATERIAL TRANSITIONS WHICH OCCUR AT

DOORWAYS, TERMINATE FINISH TRANSITION AND TRANSITION

STRIP UNDER THE DOOR AT THE DOOR STOP OR CENTER

UNDER THE CLOSED DOOR.

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

MEN'S TOILET

JANITOR

VESTIBULE

ELEC

STAIR #1

HYDR. ELEV.

WOMEN'S TOILET

CLOSET

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CONFERENCE ROOM

ELEC. ELEV.

CORRIDOR

STAIR #2

S2

STAIR #3

S3

FACE OF FLOOR SLAB

COVE STICK

SHEET VINYL & INTEGRAL

BASE

CAULK TO SEAL

3/8" RADIUS BASE COVE

SCHEDULED PARTITION -

RE: PLANS

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

A B

KEY PLAN

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

N

S A

S C

IT

Y

D

IS

T R

IC

T

E

T

H S

T R

E E

T K

A N

S A

S C

IT

Y

M

O

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

P N

SHEET ID

C E

R T

IF

IE

D F

IN

A

L

2 864 10

E

F

G

N.T.S.

NORTH

A s i n d ic a te d

A-703

S B

G A

S B

/2

/2

Z H

T V

W P

A F

B X

T A

L

Z H

T V

W P

A F

B X

T A

L R

E N

O V

A T

IO

N

F

IR

S T

F L O

O R

F

IN

IS

H

A N

D S

IG

N

A G

E P

L A

N

A R

E A

A

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

SCALE: 1/8" = 1'-0"A1

FIRST FLOOR FINISH AND SIGNAGE PLAN - AREA A

SCALE IN FEET

0 4' 8' 16'

NORTH

SCALE: 6" = 1'-0"C8

INTEGRAL BASE DETAIL

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

C

E R

T

IF

IE

D

F

IN

A L

M A