This federal solicitation seeks proposals for the renovation of an aircraft maintenance hangar and construction of an addition at Homestead Air Reserve Base in Florida. The project has an estimated cost between $10-25 million and is a full and open competition in accordance with FAR 19.1307, requiring a 10% price evaluation preference for HUBZone small businesses. Proposals are due by 4 September 2020 with award timing dependent on available appropriated funds. The solicitation includes replacement drawings and specifications along with instructions for bidder inquiries and registration requirements.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CIVIL/OPS/ENVIRONMENTAL BR
ATTN: GLENN W MOON
600 DR M L KING JR PL RM 821
LOUISVILLE KY 40202-2236
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
See Continuation Page.
1. CONTRACT ID CODE PAGE OF PAGES
1 5
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912QR20R0078
X 9B. DATED (SEE ITEM 11)
04-Aug-2020
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO.
5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
28-Aug-2020
CODE
U. S. ARMY ENGINEER DISTRICT, LOUISVILLE
600 DR. MARTIN LUTHER KING, JR. PLACE
ROOM 821
LOUISVILLE KY 40202-2239
W912QR 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE 964860
FACILITY CODECODE
EMAIL:TEL:
W912QR20R0078-0001
W912QR20R0078
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE (SF 30)
The following have been added by full text:
SUMMARY OF CHANGES AMEND 0001
Solicitation W912QR20R0078 for the Renovation of an aircraft maintenance hangar and the construction of an addition to the hangar located at Homestead ARB, Florida is hereby modified as follows:
1. Offerors must acknowledge all amendments.
2. The due date and time for submission remains 4 September 2020 at 10:00 AM Eastern Time.
3. Section 00 70 00 Clause 52.204-25 and Section 00 45 00 Provision 52.204-24 have been replaced with their current version dated August 2020.
4. Davis Bacon Wage Determination FL20200215 is hereby deleted and replaced with the current version dated 28 August 2020.
5. The following PLAN SHEETS have been replaced in their entirety:
AD101 FIRST FLOOR DEMOLITION PLAN
A-202 EXTERIOR ELEVATIONS
ED111 FIRST FLOOR - DEMOLITION
6. The following SPECIFICATION SECTIONS have been added in their entirety:
02 84 33A LIMITED ABESTOS AND PCB SURVEY REPORT
33 12 33.00 30 WATER METERS
7. The following SPECIFICATION SECTIONS have been replaced in their entirety:
Project Table of Contents
05 12 00 STRUCTURAL STEEL
22 00 00 PLUMBING, GENERAL PURPOSE
26 20 00 INTERIOR DISTRIBUTION SYSTEM
8. All other information remains the same.
- END OF ‘SUMMARY OF CHANGES’ -
SECTION 00 45 00 - REPRESENTATIONS AND CERTIFICATIONS
The following have been added by full text:
52.204-24 REPRESENTATION REGARDING CERTAIN TELECOMMUNICATIONS AND VIDEO
SURVEILLANCE SERVICES OR EQUIPMENT (AUG 2020)
The Offeror shall not complete the representation at paragraph (d)(1) of this provision if the Offeror has represented that it "does not provide covered telecommunications equipment or services as a part of its offered products or services to the Government in the performance of any contract, subcontract, or other contractual instrument" in the provision at 52.204-26, Covered Telecommunications Equipment or Services--Representation, or in paragraph (v) of the provision at 52.212-3, Offeror Representations and Certifications-Commercial Items.
(a) Definitions. As used in this provision-
Backhaul, covered telecommunications equipment or services, critical technology, interconnection arrangements, reasonable inquiry, roaming, and substantial or essential component have the meanings provided in the clause 52.204-25, Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment.
(b) Prohibition.
(1) Section 889(a)(1)(A) of the John S. McCain National Defense Authorization Act for Fiscal Year 2019 (Pub. L.
115-232) prohibits the head of an executive agency on or after August 13, 2019, from procuring or obtaining, or extending or renewing a contract to procure or obtain, any equipment, system, or service that uses covered telecommunications equipment or services as a substantial or essential component of any system, or as critical technology as part of any system. Nothing in the prohibition shall be construed to--
(i) Prohibit the head of an executive agency from procuring with an entity to provide a service that connects to the facilities of a third-party, such as backhaul, roaming, or interconnection arrangements; or
(ii) Cover telecommunications equipment that cannot route or redirect user data traffic or cannot permit visibility into any user data or packets that such equipment transmits or otherwise handles.
(2) Section 889(a)(1)(B) of the John S. McCain National Defense Authorization Act for Fiscal Year 2019 (Pub. L.
115-232) prohibits the head of an executive agency on or after August 13, 2020, from entering into a contract or extending or renewing a contract with an entity that uses any equipment, system, or service that uses covered telecommunications equipment or services as a substantial or essential component of any system, or as critical technology as part of any system. This prohibition applies to the use of covered telecommunications equipment or services, regardless of whether that use is in performance of work under a Federal contract. Nothing in the prohibition shall be construed to--
(i) Prohibit the head of an executive agency from procuring with an entity to provide a service that connects to the facilities of a third-party, such as backhaul, roaming, or interconnection arrangements; or
(ii) Cover telecommunications equipment that cannot route or redirect user data traffic or cannot permit visibility into any user data or packets that such equipment transmits or otherwise handles.
(c) Procedures. The Offeror shall review the list of excluded parties in the System for Award Management (SAM) (https://www.sam.gov) for entities excluded from receiving federal awards for "covered telecommunications equipment or services."
(d) Representations. The Offeror represents that--
(1) It [ ] will, [ ] will not provide covered telecommunications equipment or services to the Government in the performance of any contract, subcontract or other contractual instrument resulting from this solicitation. The Offeror shall provide the additional disclosure information required at paragraph (e)(1) of this section if the Offeror responds "will" in paragraph (d)(1) of this section; and
(2) After conducting a reasonable inquiry, for purposes of this representation, the Offeror represents that--
It [ ] does, [ ] does not use covered telecommunications equipment or services, or use any equipment, system, or service that uses covered telecommunications equipment or services. The Offeror shall provide the additional disclosure information required at paragraph (e)(2) of this section if the Offeror responds "does" in paragraph (d)(2) of this section.
(e) Disclosures.
(1) Disclosure for the representation in paragraph (d)(1) of this provision. If the Offeror has responded "will" in the representation in paragraph (d)(1) of this provision, the Offeror shall provide the following information as part of the offer:
(i) For covered equipment--
(A) The entity that produced the covered telecommunications equipment (include entity name, unique entity identifier, CAGE code, and whether the entity was the original equipment manufacturer (OEM) or a distributor, if known);
(B) A description of all covered telecommunications equipment offered (include brand; model number, such as OEM number, manufacturer part number, or wholesaler number; and item description, as applicable); and
(C) Explanation of the proposed use of covered telecommunications equipment and any factors relevant to determining if such use would be permissible under the prohibition in paragraph (b)(1) of this provision.
(ii) For covered services--
(A) If the service is related to item maintenance: A description of all covered telecommunications services offered (include on the item being maintained: Brand; model number, such as OEM number, manufacturer part number, or wholesaler number; and item description, as applicable); or
(B) If not associated with maintenance, the Product Service Code (PSC) of the service being provided; and explanation of the proposed use of covered telecommunications services and any factors relevant to determining if such use would be permissible under the prohibition in paragraph (b)(1) of this provision.
(2) Disclosure for the representation in paragraph (d)(2) of this provision. If the Offeror has responded "does" in the representation in paragraph (d)(2) of this provision, the Offeror shall provide the following information as part of the offer:
(i) For covered equipment--
(A) The entity that produced the covered telecommunications equipment (include entity name, unique entity identifier, CAGE code, and whether the entity was the OEM or a distributor, if known);
(B) A description of all covered telecommunications equipment offered (include brand; model number, such as OEM number, manufacturer part number, or wholesaler number; and item description, as applicable); and
(C) Explanation of the proposed use of covered telecommunications equipment and any factors relevant to determining if such use would be permissible under the prohibition in paragraph (b)(2) of this provision.
(ii) For covered services--
(A) If the service is related to item maintenance: A description of all covered telecommunications services offered (include on the item being maintained: Brand; model number, such as OEM number, manufacturer part number, or wholesaler number; and item description, as applicable); or
(B) If not associated with maintenance, the PSC of the service being provided; and explanation of the proposed use of covered telecommunications services and any factors relevant to determining if such use would be permissible under the prohibition in paragraph (b)(2) of this provision.
(End of provision)
The following have been deleted:
52.204-24 Representation Regarding Certain Telecommunications and
Video Surveillance Services or Equipment.
DEC 2019
SECTION 00 70 00 - CONDITIONS OF THE CONTRACT
The following have been added by reference:
52.204-25 Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment.
AUG 2020
The following have been deleted:
52.204-25 Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment.
AUG 2019
(End of Summary of Changes)
General Decision Number: FL20200215 08/28/2020
Superseded General Decision Number: FL20190215
State: Florida
Construction Type: Building
County: Miami-Dade County in Florida.
BUILDING CONSTRUCTION PROJECTS (does not include single family homes or apartments up to and including 4 stories).
Note: Under Executive Order (EO) 13658, an hourly minimum wage of $10.80 for calendar year 2020 applies to all contracts subject to the Davis-Bacon Act for which the contract is awarded (and any solicitation was issued) on or after January 1, 2015. If this contract is covered by the EO, the contractor must pay all workers in any classification listed on this wage determination at least $10.80 per hour (or the applicable wage rate listed on this wage determination, if it is higher) for all hours spent performing on the contract in calendar year 2020. If this contract is covered by the EO and a classification considered necessary for performance of work on the contract does not appear on this wage determination, the contractor must pay workers in that classification at least the wage rate determined through the conformance process set forth in 29 CFR 5.5(a)(1)(ii) (or the EO minimum wage rate,if it is higher than the conformed wage rate). The EO minimum wage rate will be adjusted annually. Please note that this EO applies to the above-mentioned types of contracts entered into by the federal government that are subject to the Davis-Bacon Act itself, but it does not apply to contracts subject only to the Davis-Bacon Related Acts, including those set forth at 29 CFR 5.1(a)(2)-(60). Additional information on contractor requirements and worker protections under the EO is available at www.dol.gov/whd/govcontracts.
Modification Number Publication Date 0 01/03/2020 1 02/21/2020 2 02/28/2020 3 05/15/2020 4 08/28/2020
ASBE0060-001 03/02/2016
Rates Fringes
ASBESTOS WORKER/HEAT & FROST
INSULATOR........................$ 34.58 12.57
CARP1809-002 08/01/2016
Rates Fringes
CARPENTER: PILEDRIVERMAN.........$ 25.20 10.36
ELEV0071-002 01/01/2020
Rates Fringes
ELEVATOR MECHANIC................$ 45.91 34.765
FOOTNOTE:
A: Employer contributes 8% basic hourly rate for 5 years or more of service or 6% basic hourly rate for 6 months to 5 years of service as Vacation Pay Credit; Paid Holidays:
New Year's Day; Memorial Day; Independence Day; Labor Day;
Veteran's Day; Thanksgiving Day; plus the Friday after Thanksgiving; and Christmas Day.
ENGI0487-019 07/01/2016
Rates Fringes
OPERATOR:
Backhoe/Excavator/Trackhoe.......$ 23.75 9.20
ENGI0487-020 05/01/2016
Rates Fringes
OPERATOR: Concrete Pump.........$ 26.04 9.23
ENGI0487-021 07/01/2016
Rates Fringes
OPERATOR: Crane All Cranes 160 Ton Capacity and Over...........$ 33.05 9.20 All Cranes Over 15 Ton Capacity....................$ 32.05 9.20 OPERATOR: Forklift..............$ 23.25 9.20 OPERATOR: Mechanic..............$ 32.05 9.20 OPERATOR: Oiler.................$ 23.50 9.20
IRON0272-001 10/01/2019
Rates Fringes
IRONWORKER, STRUCTURAL...........$ 25.49 11.99
IRON0402-001 01/01/2019
Rates Fringes
IRONWORKER, ORNAMENTAL...........$ 23.69 12.70
PLUM0519-001 10/31/2019
Rates Fringes
PLUMBER..........................$ 30.63 11.64
PLUM0725-001 07/16/2018
Rates Fringes
PIPEFITTER (Includes HVAC Pipe, Unit and Temperature Controls Installations)..........$ 35.63 14.15
* SFFL0821-004 07/01/2020
Rates Fringes
SPRINKLER FITTER (Fire Sprinklers)......................$ 29.88 19.75
SHEE0032-001 12/01/2013
Rates Fringes
SHEET METAL WORKER, Includes HVAC Duct Installation...........$ 23.50 12.18
SUFL2014-024 08/16/2016
Rates Fringes
CARPENTER, Includes Acoustical Ceiling Installation, Drywall Finishing/Taping, Drywall Hanging, Form Work, Metal Stud Installation................$ 18.04 3.24
CEMENT MASON/CONCRETE FINISHER...$ 13.06 0.70
ELECTRICIAN, Includes Low Voltage Wiring...................$ 29.60 9.38
IRONWORKER, REINFORCING..........$ 17.72 0.00
LABORER: Common or General, Including Cement Mason Tending...$ 11.79 0.70
LABORER: Pipelayer..............$ 13.56 1.34
OPERATOR: Bulldozer.............$ 15.40 1.90
OPERATOR: Grader/Blade..........$ 18.97 0.00
OPERATOR: Loader................$ 16.00 2.82
OPERATOR: Roller................$ 14.43 4.78
PAINTER: Brush, Roller and Spray............................$ 16.00 3.48
ROOFER...........................$ 19.98 4.77
TILE SETTER......................$ 18.01 0.00
TRUCK DRIVER: Dump Truck........$ 13.22 2.12
TRUCK DRIVER: Lowboy Truck......$ 14.24 0.00
WELDERS - Receive rate prescribed for craft performing operation to which welding is incidental.
Note: Executive Order (EO) 13706, Establishing Paid Sick Leave for Federal Contractors applies to all contracts subject to the Davis-Bacon Act for which the contract is awarded (and any solicitation was issued) on or after January 1, 2017. If this contract is covered by the EO, the contractor must provide employees with 1 hour of paid sick leave for every 30 hours they work, up to 56 hours of paid sick leave each year.
Employees must be permitted to use paid sick leave for their own illness, injury or other health-related needs, including preventive care; to assist a family member (or person who is like family to the employee) who is ill, injured, or has other health-related needs, including preventive care; or for reasons resulting from, or to assist a family member (or person who is like family to the employee) who is a victim of, domestic violence, sexual assault, or stalking. Additional information on contractor requirements and worker protections under the EO is available at www.dol.gov/whd/govcontracts.
Unlisted classifications needed for work not included within the scope of the classifications listed may be added after award only as provided in the labor standards contract clauses (29CFR 5.5 (a) (1) (ii)).
The body of each wage determination lists the classification and wage rates that have been found to be prevailing for the cited type(s) of construction in the area covered by the wage determination. The classifications are listed in alphabetical order of ""identifiers"" that indicate whether the particular rate is a union rate (current union negotiated rate for local), a survey rate (weighted average rate) or a union average rate (weighted union average rate).
Union Rate Identifiers
A four letter classification abbreviation identifier enclosed in dotted lines beginning with characters other than ""SU"" or ""UAVG"" denotes that the union classification and rate were prevailing for that classification in the survey. Example:
PLUM0198-005 07/01/2014. PLUM is an abbreviation identifier of the union which prevailed in the survey for this classification, which in this example would be Plumbers. 0198 indicates the local union number or district council number where applicable, i.e., Plumbers Local 0198. The next number, 005 in the example, is an internal number used in processing the wage determination. 07/01/2014 is the effective date of the most current negotiated rate, which in this example is July 1, 2014.
Union prevailing wage rates are updated to reflect all rate changes in the collective bargaining agreement (CBA) governing this classification and rate.
Survey Rate Identifiers
Classifications listed under the ""SU"" identifier indicate that no one rate prevailed for this classification in the survey and the published rate is derived by computing a weighted average rate based on all the rates reported in the survey for that classification. As this weighted average rate includes all rates reported in the survey, it may include both union and non-union rates. Example: SULA2012-007 5/13/2014. SU indicates the rates are survey rates based on a weighted average calculation of rates and are not majority rates. LA indicates the State of Louisiana. 2012 is the year of survey on which these classifications and rates are based. The next number, 007 in the example, is an internal number used in producing the wage determination. 5/13/2014 indicates the survey completion date for the classifications and rates under that identifier.
Survey wage rates are not updated and remain in effect until a new survey is conducted.
Union Average Rate Identifiers
Classification(s) listed under the UAVG identifier indicate that no single majority rate prevailed for those classifications; however, 100% of the data reported for the classifications was union data. EXAMPLE: UAVG-OH-0010 08/29/2014. UAVG indicates that the rate is a weighted union average rate. OH indicates the state. The next number, 0010 in the example, is an internal number used in producing the wage determination. 08/29/2014 indicates the survey completion date for the classifications and rates under that identifier.
A UAVG rate will be updated once a year, usually in January of each year, to reflect a weighted average of the current negotiated/CBA rate of the union locals from which the rate is based.
WAGE DETERMINATION APPEALS PROCESS
1.) Has there been an initial decision in the matter? This can be:
* an existing published wage determination
* a survey underlying a wage determination
* a Wage and Hour Division letter setting forth a position on a wage determination matter
* a conformance (additional classification and rate) ruling
On survey related matters, initial contact, including requests for summaries of surveys, should be with the Wage and Hour Regional Office for the area in which the survey was conducted because those Regional Offices have responsibility for the Davis-Bacon survey program. If the response from this initial contact is not satisfactory, then the process described in 2.)
and 3.) should be followed.
With regard to any other matter not yet ripe for the formal process described here, initial contact should be with the Branch of Construction Wage Determinations. Write to:
Branch of Construction Wage Determinations Wage and Hour Division U.S. Department of Labor 200 Constitution Avenue, N.W.
Washington, DC 20210
2.) If the answer to the question in 1.) is yes, then an interested party (those affected by the action) can request review and reconsideration from the Wage and Hour Administrator (See 29 CFR Part 1.8 and 29 CFR Part 7). Write to:
Wage and Hour Administrator U.S. Department of Labor 200 Constitution Avenue, N.W.
Washington, DC 20210
The request should be accompanied by a full statement of the interested party's position and by any information (wage payment data, project description, area practice material, etc.) that the requestor considers relevant to the issue.
3.) If the decision of the Administrator is not favorable, an interested party may appeal directly to the Administrative Review Board (formerly the Wage Appeals Board). Write to:
Administrative Review Board U.S. Department of Labor 200 Constitution Avenue, N.W.
Washington, DC 20210
4.) All decisions by the Administrative Review Board are final.
END OF GENERAL DECISION
PROJECT TABLE OF CONTENTS
Amendment 0001
VOLUME 1
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
00 80 00.00 06 SPECIAL PROVISIONS
00 80 00.00 06A CONSTRUCTION PROJECT SIGN DETAILS
00 80 00.00 06B SUBMITTAL REGISTER
DIVISION 01 - GENERAL REQUIREMENTS
01 11 00 SUMMARY OF WORK
01 11 00A SHEET INDEX
01 32 01.00 06 PROJECT SCHEDULE
01 33 00.00 06 SUBMITTAL PROCEDURES
01 33 29.00 06 SUSTAINABILITY REPORTING
01 35 26.00 06 GOVERNMENT SAFETY REQUIREMENTS
01 35 26.01 06 FORM 16-1 Cert of Compliance
35 26.02 06 FORM 1259 AHA Nov 2013
01 42 00 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00.15 10 RESIDENT MANAGEMENT SYSTEM CONTRACTOR MODE (RMS CM)
01 45 04.10 06 CONTRACTOR QUALITY CONTROL
01 45 35 SPECIAL INSPECTIONS
01 46 00.00 06 TOTAL BUILDING COMMISSIONING
01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
01 57 19.00 06 TEMPORARY ENVIRONMENTAL CONTROLS AND PERMITS
01 74 19 CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL
01 78 23 OPERATION AND MAINTENANCE DATA
DIVISION 02 - EXISTING CONDITIONS
02 22 13 MOVEMENT AND VIBRATION ASSESSMENT
02 41 00 DEMOLITION
02 83 13.00 06 LEAD IN CONSTRUCTION
02 84 33 REMOVAL AND DISPOSAL OF POLYCHLORINATED BIPHENYLS (PCBs)
Amendment 0001***********************************************************
02 84 33A LIMITED ASBESTOS AND PCB SURVEY REPORT
***********************************************************Amendment 0001
02 87 33 BIRD, BAT AND RODENT DROPPINGS REMEDIATION AND DISPOSAL
DIVISION 03 - CONCRETE
03 30 00 CAST-IN-PLACE CONCRETE
03 62 15.00 06 FLOWABLE FILL
DIVISION 04 - MASONRY
04 20 00 UNIT MASONRY
DIVISION 05 - METALS
05 12 00 STRUCTURAL STEEL
05 21 00 STEEL JOIST FRAMING
05 30 00 STEEL DECKS
05 40 00 COLD-FORMED METAL FRAMING
05 50 13 MISCELLANEOUS METAL FABRICATIONS
05 51 00 METAL STAIRS
05 52 00 METAL RAILINGS
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
06 10 00 ROUGH CARPENTRY
06 41 16.00 10 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
06 61 16 SOLID SURFACING FABRICATIONS
VOLUME 2
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 14 00 FLUID-APPLIED WATERPROOFING
07 21 13 BOARD AND BLOCK INSULATION
07 21 16 MINERAL FIBER BLANKET INSULATION
07 22 00 ROOF AND DECK INSULATION
07 27 10.00 10 BUILDING AIR BARRIER SYSTEM
07 27 19.01 SELF-ADHERING AIR BARRIERS
07 27 26 FLUID-APPLIED MEMBRANE AIR BARRIERS
07 41 13 METAL ROOF PANELS
07 42 13 METAL WALL PANELS
07 60 00 FLASHING AND SHEET METAL
07 72 46 ROOF WALKWAYS
07 84 00 FIRESTOPPING
07 92 00 JOINT SEALANTS
DIVISION 08 - OPENINGS
08 11 13 STEEL DOORS AND FRAMES
08 14 00 WOOD DOORS
08 33 23 OVERHEAD COILING DOORS
08 34 16.10 STEEL SLIDING HANGAR DOORS
08 71 00 DOOR HARDWARE
08 81 00 GLAZING
DIVISION 09 - FINISHES
09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD
09 29 00 GYPSUM BOARD
09 30 10 CERAMIC, QUARRY, AND GLASS TILING
09 51 00 ACOUSTICAL CEILINGS
09 62 38 STATIC-CONTROL FLOORING
09 65 00 RESILIENT FLOORING
09 67 23.15 FUEL RESISTIVE RESINOUS FLOORING, 3-COAT SYSTEM
09 68 00 CARPETING
09 90 00 PAINTS AND COATINGS
09 97 13.27 EXTERIOR COATING OF STEEL STRUCTURES
DIVISION 10 - SPECIALTIES
10 11 00 VISUAL DISPLAY UNITS
10 14 00.20 INTERIOR SIGNAGE
10 21 13 TOILET COMPARTMENTS
10 21 23.16 CUBICLE TRACK AND HARDWARE
10 26 00 WALL AND DOOR PROTECTION
10 28 13 TOILET ACCESSORIES
10 41 16 EMERGENCY KEY CABINETS
10 44 16 FIRE EXTINGUISHERS
10 81 13 BIRD CONTROL DEVICES
DIVISION 12 - FURNISHINGS
12 22 00 CURTAINS AND DRAPES
12 50 00.13 10 FURNITURE AND FURNITURE INSTALLATION
DIVISION 13 - SPECIAL CONSTRUCTION
13 34 19 METAL BUILDING SYSTEMS
DIVISION 14 - CONVEYING EQUIPMENT
14 24 23 HYDRAULIC PASSENGER ELEVATORS
DIVISION 21 - FIRE SUPPRESSION
21 13 13.00 10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION
21 13 25 HIGH-EXPANSION FOAM SYSTEM, FIRE PROTECTION
21 90 00 FIRE PROTECTION SYSTEM COMMISSIONING
DIVISION 22 - PLUMBING
22 00 00 PLUMBING, GENERAL PURPOSE
22 15 14.00 40 GENERAL SERVICE COMPRESSED-AIR SYSTEMS, LOW PRESSURE
VOLUME 3
DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)
23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS
23 05 93.00 06 TESTING, ADJUSTING, AND BALANCING (TAB) OF HVAC
23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS
23 09 00 INSTRUMENTATION AND CONTROL FOR HVAC
23 09 13 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC
23 09 23.02 BACNET DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING
CONTROL SYSTEMS
23 23 00 REFRIGERANT PIPING
23 64 10 WATER CHILLERS, VAPOR COMPRESSION TYPE
23 64 26 CHILLED WATER PIPING SYSTEMS
23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT
DIVISION 25 - INTEGRATED AUTOMATION
25 10 10 UTILITY MONITORING AND CONTROL SYSTEM (UMCS) FRONT
END AND INTEGRATION
DIVISION 26 - ELECTRICAL
26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS
26 08 00 APPARATUS INSPECTION AND TESTING
26 20 00 INTERIOR DISTRIBUTION SYSTEM
26 27 13.10 30 ELECTRIC METERS
26 29 23 VARIABLE FREQUENCY DRIVE SYSTEMS UNDER 600 VOLTS
26 41 00 LIGHTNING PROTECTION SYSTEM
26 51 00 INTERIOR LIGHTING
26 56 00 EXTERIOR LIGHTING
DIVISION 27 - COMMUNICATIONS
27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY
28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM
DIVISION 31 - EARTHWORK
31 00 00.00 06 EARTHWORK
31 21 13 RADON MITIGATION
DIVISION 32 - EXTERIOR IMPROVEMENTS
32 01 11.51 PAINT REMOVAL FROM AIRFIELD PAVEMENTS
32 11 23 AGGREGATE BASE COURSES
32 16 19 CONCRETE CURBS, GUTTERS AND SIDEWALKS
32 17 23 PAVEMENT MARKINGS
32 31 13 CHAIN LINK FENCES AND GATES
DIVISION 33 - UTILITIES
33 11 00 WATER UTILITY DISTRIBUTION PIPING
Amendment 0001 ****************************************
33 12 33.00 30 WATER METERS
*****************************************Amendment 0001
33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION
33 82 00 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)
DIVISION 41 - MATERIAL PROCESSING AND HANDLING EQUIPMENT
41 22 13.15 BRIDGE CRANES, OVERHEAD ELECTRIC, UNDER RUNNING
-- End of Project Table of Contents --
P2#478240 - Add/Repair Unscheduled Maintenance Hangar 200
Homestead ARB, FL
02 84 33A Page 1
AMENDMENT 0001
LIMITED ASBESTOS AND PCB SURVEY REPORT
Amendment 0001
Limited Asbestos and PCB Survey Report
Homestead Air Reserve Base - Hangar 200 29050 Coral Sea Boulevard
Homestead, Miami-Dade County, Florida March 18, 2019
Terracon Project No. H8197001
Prepared for:
BENHAM A HASKELL COMPANY
Oklahoma City, Oklahoma
Prepared by:
Terracon Consultants, Inc.
Fort Lauderdale, Florida
Terracon Consultants, Inc. 5371 NW 33r d Avenue, Suite 201 Fort Lauderdale, Florida 33309 P [954] 741 8282 F [954] 741 8240 terracon.com
March 18, 2019
Benham, A Haskell Company 9400 North Broadway, Suite 300 Oklahoma City, OK 73114
Attn: Mr. Dylan Motley, Structural Engineer P: (405) 478-5353 M: (405) 607-7963 E: dylan.motley@benham.com
Re: Limited Asbestos and PCB Survey Report Homestead Air Reserve Base - Hangar 200 29050 Coral Sea Boulevard Homestead, Miami-Dade County, Florida Terracon Project No. H8197001
Dear Mr. Motley:
Terracon Consultants, Inc. (Terracon) is pleased to submit the attached report for the above referenced project to Benham, A Haskell Company. The purpose of this report is to present the results of the limited asbestos and PCB survey performed on March 11, 2019 at the Homestead Air Reserve Base in Homestead, Florida. The surveys were conducted in general accordance with Terracon’s work authorization (WA1500518) dated January 24, 2019. We understand that the survey was requested prior to the renovation or demolition of the Hangar 200.
Asbestos was not identified in the samples collected and analyzed for this project. Additionally, Potential PCB components were identified. Please refer to the attached report for details.
Terracon appreciates the opportunity to provide this service to BENHAM A HASKELL COMPANY. If you have any questions regarding this report, please contact Mr. Sergio A. Adasme at 954-703-1865.
Sincerely, Terracon Consultants, Inc.
Florida Asbestos Business License Number ZA-337
Prepared By: Reviewed By:
Sergio A. Adasme Russell E. Stauffer, P.E.
Environmental Services Licensed Asbestos Consultant No. EA-16 Senior Industrial Hygiene Consultant Authorized Project Reviewer mailto:dylan.motley@benham.com
Reliable ■ Responsive ■ Convenient ■ Innovative
TABLE OF CONTENTS
EXECUTIVE SUMMARY
1.0 INTRODUCTION
1.1 Project Objective
1.2 Reliance
2.0 BUILDING DESCRIPTION
3.0 FIELD ACTIVITIES
3.1 Asbestos
4.0 REGULATORY OVERVIEW
4.1 Asbestos
4.2 PCB
5.0 FINDINGS AND RECOMMENDATIONS
5.1 Asbestos
5.2 PCB
6.0 LIMITATIONS/GERNERAL COMMENTS
APPENDICES
APPENDIX A ASBESTOS SURVEY SAMPLE SUMMARY
APPENDIX B ASBESTOS ANALYTICAL LABORATORY DATA
APPENDIX C LICENSES AND CERTIFICATIONS
APPENDIX D PHOTOGRAPHS
Limited Asbestos & PCB Survey Report Homestead Air Reserve Base – Hangar 200 ■ Homestead, Florida March 18, 2019 ■ Terracon Project No. H8197001
Reliable ■ Responsive ■ Convenient ■ Innovative
EXECUTIVE SUMMARY
Terracon Consultants, Inc. (Terracon) conducted a limited asbestos & visual PCB survey of the Homestead Air Reserve Base – Hangar 200 in Homestead, Florida. The purpose of this survey was to sample and identify suspect asbestos-containing materials (ACM) and provide information regarding the identity, location, condition and approximate quantities of ACM in interior and exterior building components of the structure. In addition, a visual survey was performed to identify potential Polychlorinated biphenyl - (PCB) items that might also be impacted by the planned renovation or demolition.
The survey was performed on March 11, 2019 by an Asbestos Hazard Emergency Response Act (AHERA)-accredited asbestos inspector in general accordance with Terracon’s work authorization (WA1500518) dated January 24, 2019, and the sampling protocols established in EPA 40 CFR
763. A total of 79 bulk samples were collected from 23 homogeneous areas of suspect ACM.
Asbestos was not identified in the samples collected and analyzed for this project.
The following PCB components were among those identified in the four huts:
n Electrical Switches n Light Ballasts n Transformers n Emergency Exit Signs n Circuit Breaker Box n Air Handling Unit
The results of this assessment should be communicated to the renovation or demolition contractor and other subcontractors working in the building and a copy of the survey should be on-site during renovation or demolition activities. In addition, due to the demolition, a 10-day notice needs to be submitted to the local NESHAP regulatory agency.
Any concealed building materials discovered during renovation or demolition activities not identified in this report, which are suspected to contain asbestos, should be sampled by a Florida Licensed Asbestos Consultant and analyzed by a NVLAP-accredited laboratory to confirm the presence or absence of asbestos prior to disturbing such materials. Likewise, if other suspect ACM or PCB components are identified, various regulations (EPA NESHAP, DERM, OSHA, etc.) will apply.
Please refer to the report for further details.
March 18, 2019 ■ Terracon Project No. H8197001
Reliable ■ Responsive ■ Convenient ■ Innovative 1
LIMITED ASBESTOS SURVEY & PCB SURVEY REPORT
Homestead Air Reserve Base - Hangar 200
29050 Coral Sea Boulevard Homestead, Miami-Dade County, Florida
Terracon Project No. H8197001 March 18, 2019
1.0 INTRODUCTION
Terracon performed a limited asbestos and visual Polychlorinated biphenyl - (PCB) survey on March 11, 2019 at Homestead Air Reserve – Hangar 200 located in Homestead, Florida. The survey was performed at your request to assess potential hazardous materials that may be present to accommodate the planned renovation or demolition activities at the facility.
The assessment was conducted by Terracon’s State of Florida approved asbestos building inspectors Messrs. Daniel Reyes & Filippo Di Graci. Terracon applicable licenses and certifications are presented in Appendix C.
Building components were surveyed and homogeneous areas of suspect asbestos-containing materials (ACM) were visually identified and documented. Although reasonable effort was made to survey accessible suspect materials, additional suspect but un-sampled materials and/or issues could be located in walls, in voids, below the ground or in other concealed areas.
Suspect ACM samples were collected in general accordance with the sampling protocols outlined in EPA regulation 40 CFR 763 (Asbestos Hazard Emergency Response Act, AHERA). Asbestos samples were delivered to an accredited laboratory for analysis. Suspect ACM samples were analyzed by Polarized Light Microscopy. In addition, visual observations were performed to identify potential PCM building components.
1.1 Project Objective
We understand this asbestos survey was requested due to the planned renovation or demolition of the structures to satisfy requirements of the USEPA regulation 40 CFR 61, Subpart M, National Emission Standards for Hazardous Air Pollutants (NESHAP). NESHAP regulations prohibit the release of asbestos fibers to the atmosphere during renovation or demolition activities. The asbestos NESHAP requires that potentially regulated ACM (RACM) be identified, classified and quantified prior to planned disturbances or demolition activities. In addition, the need to identify potential PCB components was required due to the planned renovation/demolition activities.
March 18, 2019 ■ Terracon Project No. H8197001
Reliable ■ Responsive ■ Convenient ■ Innovative 2
1.2 Reliance
This report is for the exclusive use of BENHAM A HASKELL COMPANY for the project being discussed. Reliance by any other party on this report is prohibited without written authorization of Terracon and BENHAM A HASKELL COMPANY. Reliance on this report by BENHAM A HASKELL COMPANY and all authorized parties will be subject to the terms, conditions, and limitations stated in the proposal, this report and Terracon’s Agreement for Services. The limitations of liability defined in Terracon’s Agreement for Services is the aggregate limit of Terracon’s liability to BENHAM A HASKELL COMPANY.
2.0 BUILDING DESCRIPTION
The hangar is two-story structure, it was most likely built in 1955, which is the year the base was built. The purpose of the Hangar is to house the F-16’s under repair as well as offices. The hangar is estimated at about 30,000 square-feet and rest on concrete slab. The walls are concrete block and interior finishes include drywall
3.0 FIELD ACTIVITIES
The survey was conducted in general accordance with the sample collection protocols established in USEPA AHERA regulations 40 CFR 763.86. A summary of survey activities is provided below.
3.1 Asbestos
Survey activities were initiated with visual observations of the designated interior and exterior materials of the buildings to identify homogeneous areas of suspect ACM. A homogeneous area (HA) consists of building materials that appear similar throughout in terms of color and texture with consideration given to the date of application.
A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material which can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.
Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with AHERA sampling protocols. Samples of suspect materials were collected randomly selected locations in each homogeneous area. Bulk samples were collected using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content. Seventy-nine (79) bulk samples were collected from twenty-three (23) homogeneous areas of suspect ACM. A listing of suspect ACM observed and sampled during the survey is documented in Appendix A:
March 18, 2019 ■ Terracon Project No. H8197001
Reliable ■ Responsive ■ Convenient ■ Innovative 3
Bulk samples were submitted under chain of custody to EMLab P&K of Fort Lauderdale, Florida for analysis by PLM per EPA methodology EPA/600/R-93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation. EMLab P&K is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP Accreditation No. 200738-0).
4.0 REGULATORY OVERVIEW
4.1 Asbestos
The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. It also requires the identification and classification of existing building materials prior to demolition or renovation activity. Under NESHAP, asbestos-containing building materials are classified as either friable, Category I non-friable or Category II non-friable ACM. Friable materials are those that, when dry, may be crumbled, pulverized or reduced to powder by hand pressure. Category I non-friable ACM includes packings, gaskets, resilient floor coverings and asphalt roofing products containing more than 1% asbestos. Category II non-friable ACM are any materials other than Category I materials that contain more than 1% asbestos.
Friable ACM, Category I and Category II non-friable ACM which is in poor condition and has become friable or which will be subjected to drilling, sanding, grinding, cutting or abrading and which could be crushed or pulverized during anticipated renovation or demolition activities are considered regulated ACM (RACM).
In the State of Florida, asbestos activities are regulated by the Florida Department of Environmental Protection (FDEP), which is enforced locally by the Miami Dade County, the local designee for NESHAP notification and enforcement is the Miami-Dade, Division of Environmental Resource Management (DERM), which is located at 701 N.W. 1st Court, Suite 400, Miami FL, 33136. RACM must be removed prior to renovation or demolition activities which will disturb the materials. The owner or operator must provide the FDEP with written notification of planned removal activities at least 10 working days prior to the commencement of asbestos abatement activities. Removal of RACM must be conducted by a State of Florida-licensed asbestos abatement contractor.
The OSHA Asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard requires that employee exposure to airborne asbestos fibers be maintained below their two Permissible Exposure Limit (PEL) of 0.1 asbestos fibers per cubic centimeter of air (0.1 f/cc) over an 8-hour Time-weighted Average (TWA) and a 30-minute TWA Excursion Limit of 1.0 f/cc. The OSHA standard classifies construction and maintenance activities which could disturb ACM and specifies work practices and precautions which employers must follow when engaging in each class of regulated work.
March 18, 2019 ■ Terracon Project No. H8197001
Reliable ■ Responsive ■ Convenient ■ Innovative 4
4.2 PCB
The United States Environmental Protection Agency (USEPA) regulates bulk PCB product waste under 40 Code of Federal Regulations (CFR) 761.62 of the Toxic Substances Control Act (TSCA).
State of Florida hazardous materials regulations are addressed in Florida Administrative Code (FAC) rule 63.730- Hazardous Waste. Equipment such as transformers may contain mineral oil with minor amounts of PCBs and could be considered “PCB contaminated” (PCB content 50-500 ppm). The generator is responsible for compliance with applicable regulations regarding hazardous waste disposal.
5.0 FINDINGS AND RECOMMENDATIONS
5.1 Asbestos
Asbestos was not identified by the laboratory in the samples collected by Terracon. An Asbestos Survey Sampling Summary is included in Appendix A and the Asbestos Laboratory Analytical Report is included in Appendix B.
n The results of this assessment should be communicated to the renovation contractor and other subcontractors working in the building and a copy of the survey should be on-site during the renovation activities.
n Any concealed building materials discovered during renovation activities not identified in this report, which are suspected to contain asbestos, should be sampled by a Florida Licensed Asbestos Consultant and analyzed by a NVLAP-accredited laboratory to confirm the presence or absence of asbestos prior to disturbing such materials. If the materials are found to contain asbestos, various regulations (EPA NESHAP, Miami Dade County Department of Environmental Resource Management (DERM), and OSHA) will apply.
n In addition, direct contact with the Miami-Dade County Division of Environmental Resources Management (DERM) at (305) 372-6925 is recommended to confirm their actual regulatory requirements.
March 18, 2019 ■ Terracon Project No. H8197001
Reliable ■ Responsive ■ Convenient ■ Innovative 5
5.2 PCB
The following table identifies materials likely to contain PCB.
Material Location Approximate Quantity
Photo # (See Appendix D)
Electrical Switches Throughout the Hangar
11 2
Lighting Ballasts Throughout the Hangar
235 3 & 5
Emergency Exit Signs Throughout the Hangar
7 3 & 4
Transformer Electrical Room 1 5 Heavy Duty Safety Switch Electrical and
Mechanical Room 2 1
Circuit Breaker Box Electrical Room 8 5 & 6 Air Handling Unit Mechanical Room 1 1
Contractors performing removal, disposal or recycling activities should employ engineering and work controls to maintain exposures below applicable levels and should be trained in the provisions of OSHA 29 CFR 1910.120 (Hazard Communication) and 29 CFR 1910.1200 (Hazardous Waste Operations), at a minimum. We also suggest that the contractor performing removal of the identified materials contact the selected disposal / recycling facility prior to transport to determine if any modified procedures are necessary.
6.0 LIMITATIONS/GENERAL COMMENTS
It should be noted that suspect asbestos materials other than those identified during the March 11, 2019 survey may exist in locations outside of the designated surveyed areas. Should suspect materials other than those which were identified during this survey be uncovered prior to demolition activities, those materials should be assumed asbestos-containing.
The asbestos survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our survey of the building. The information contained in this report is relevant to the date on which this survey was performed and should not be relied upon to represent conditions at a later date.
Likewise, other possibly PCB materials may exist and if identified during the demolition activities it should be brought to the attention of Terracon for potential assessment.
March 18, 2019 ■ Terracon Project No. H8197001
Reliable ■ Responsive ■ Convenient ■ Innovative 6
This report has been prepared on behalf of and exclusively for use by BENHAM A HASKELL COMPANY for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.
APPENDIX A
ASBESTOS SURVEY SAMPLE SUMMARY
Sample No.
Location Martial Quantity
(NESHAPS
Category)
Laboratory Results
1A Side East (center) Black Exterior Caulking N/A ND 1B Side East (center) Black Exterior Caulking N/A ND 1C Side East (center) Black Exterior Caulking N/A ND 2A Door "NE" Beige Exterior Caulking N/A ND 2B Door "NE" Beige Exterior Caulking N/A ND 2C Door "NE" Beige Exterior Caulking N/A ND 3A Gate East Black Expansion Joint N/A ND 3B Gate East Black Expansion Joint N/A ND 3C Gate East Black Expansion Joint N/A ND 4A Gate "SE" Concrete Floor Slab N/A ND 4B Door South Concrete Floor Slab N/A ND 4C Gate South Concrete Floor Slab N/A ND 4D Gate West Concrete Floor Slab N/A ND 4E Gate West Concrete Floor Slab N/A ND 4F Gate North Concrete Floor Slab N/A ND 4G Gate North Concrete Floor Slab N/A ND 5A Opening Hangar Doors Hangar Insulation Modules N/A ND 5B Opening Hangar Doors Hangar Insulation Modules N/A ND 5C Opening Hangar Doors Hangar Insulation Modules N/A ND
6A Door East Men Restroom 2"x2" White Ceramic Floor Tile N/A ND
6B Door West Men
Restroom 2"x2" White Ceramic Floor Tile N/A ND
6C Wall Center-East Men
Restroom 2"x2" White Ceramic Floor Tile N/A ND
7A Door East Men Restroom 4"x4" White Ceramic Wall Tile N/A ND
7B Door West Men
Restroom 4"x4" White Ceramic Wall Tile N/A ND
7C Wall Center-East Men
Restroom 4"x4" White Ceramic Wall Tile N/A ND
8A Second Floor, West, East
Wall Drywall System w/ Joint Compound N/A ND
8B Second Floor, West, West
Wall Drywall System w/ Joint Compound N/A ND
8C Cornes SW Men
Restroom Drywall System w/ Joint Compound N/A ND
8D Door East 2nd floor Drywall System w/ Joint Compound N/A ND
ASBESTOS SURVEY SAMPLE SUMMARY
Homestead Air Reserve Base - Hangar 200, Homestead, Florida
Terracon Project No. H8197001
8E Door East Men Restroom Drywall System w/ Joint Compound N/A ND
8F Door West Men
Restroom Drywall System w/ Joint Compound N/A ND
8G Wall Center-East Men
Restroom Drywall System w/ Joint Compound N/A ND
9A Door West Men
Restroom Drywall Ceiling N/A ND
9B Door East Men Restroom Drywall Ceiling N/A ND
9C Wall Center-East Men
Restroom Drywall Ceiling N/A ND
10A Wall SW Men Restroom Black Mirror Mastic N/A ND
10B Wall SW Men Restroom Black Mirror Mastic N/A ND
10C Wall SW Men Restroom Black Mirror Mastic N/A ND
11A First Floor, By Fire
Hydran Pipes White Pipe Insulation Wrap N/A ND
11B First Floor, By Fire
Hydran Pipes White Pipe Insulation Wrap N/A ND
11C First Floor, By Fire
Hydran Pipes White Pipe Insulation Wrap N/A ND
12A Door East 2nd floor 2'x2' White Textured Ceiling Tile N/A ND
12B Hallway center 2nd floor 2'x2' White Textured Ceiling Tile N/A ND
12C Hall way corner south 2'x2' White Textured Ceiling Tile N/A ND
13A Second Floor, West, East
Wall 4" Black Vinyl Cove Base N/A ND
13B Second Floor, West, West
Wall 4" Black Vinyl Cove Base N/A ND
13C Door conference room
2nd floor 4" Black Vinyl Cove Base N/A ND
14A Second Floor, West, East
Wall Gray Carpet N/A ND
14B Second Floor, West, West
Wall Gray Carpet N/A ND
14C Door conference room
2nd floor Gray Carpet N/A ND
15A Door conference room
2nd floor 12"x12" Gray Ceramic Floor Tile N/A ND
15B Second Floor, East, Storage Room 12"x12" Gray Ceramic Floor Tile N/A ND
15C Second Floor, East, AC
Room 12"x12" Gray Ceramic Floor Tile N/A ND
16A Second Floor, East, AC
Room White AC Duct…