W912QR20R0059Plans-0003.pdf

PDF 2 MB Posted

Attached to
Westover, MA Regional ISO Maintenance Hangar
Solicitation number
W912QR20R0059
Issued by

About this file

This document provides details for a federal construction solicitation to build a regional aircraft maintenance hangar. The solicitation seeks to construct a high-bay hangar with reinforced concrete, masonry exterior walls, metal sandwich panels, electrically operated hangar doors, a structural steel frame, fire protection and alarm systems, utilities, secure communications, site improvements, and other support. The project also includes demolishing an existing building. The estimated cost range is between $25-100 million and the contract duration is approximately 730 calendar days. The solicitation number is W912QR20R0059 and is being conducted by the Department of the Army Corps of Engineers Engineering District Louisville as an unrestricted, full and open competition. NAICS code is 236220.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

12 13 14 16 17

K

L

M

N

L.3

A1

A-422

CAGED

STORAGE

AREA

CTK TOOL CRIB

CORRIDOR

MSL - SECURE

STORAGE

VEST

VEST

BENCH STOCK

MECH

COMM

ELEC

UNISEX

UNISEX

SHEET METAL SHOP

OFFICE

SATELLITE

ACCUMULATION

POINT

STORAGE

SANDING

114B

116A

102A

103A 104A

105A

107A 106A

107D

108B110C

110B

111A

112A 113A

108A 107C

110A

101B

107B

115B 13

5' - 10"

11' - 10"

S2BB S2BAS2BB

S2BB

S2BA

S2BA

S2BA

S1AB

S2BA

S2BB

S1AA

F1CA

S2BA

S2BA

M1CB

M1CB

13' - 9 5/8" 21' - 1 3/8" 10' - 7"

9'

0"

C

LE

A R

8'

1'

8'

40' - 0"

R.O.

3' - 4" 22' - 0"

R.O.

6' - 4"

S2BA

S2BA

S2BA

S2BA

S2BB

S2BB

S2BB

C

LE

A R

5'

3' - 9" 11' - 0"

S2BA S1AC

S2AC

S2BA

S2BA

S2BB

F1DA

F1DA

7'

2'

3'

7'

6'

EWC

STEEL COLUMN, TYP.-

SEE STRUC. DWGS

MIN.

4' - 0"7' - 8"

CLEAR

5' - 11 3/8"

101A 115A

001N

114A

A1

A-252

M1CC

M1CC

M

IN

RE: SECTION 10 22 12

WIREMESH PARTITION

4'

/4

5'

EEWS

EEWS

EEWS

S2BB

4' - 1" 7' - 10 1/2" 17' - 0" 16' - 8"

CLEAR

6' - 0"

17' - 0"

F1DA

F1DA S1AB

F1DA

F1DA

F1DA

F1DA

F1DA S1AB

SIM

100' - 0"

99' - 7 1/4"

99' - 7 1/4"

C5

SIM

A-102

D5

SIM

A-102

A5

SIM

A-102

D5

SIM

A-102

ALIGN EDGE OF RAMP

WITH CONC. JOINT

3'

C3

A-452

A3

A-452

C1

A-452

A1

A-452

EXPANSION

JOINT

EXPANSION

JOINT

D E

S

IG

N E

D B

Y

1 432

A

B

C

D

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S L O

U

IS

V

IL

L E

K

E N

T U

C K

Y D

W N

B Y

C

K D

B Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

D A

T E

P R

O J E

C T

N O

P

N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

A F

-2 -1

-0

CERTIFIED FINAL

S O

L

IC

IT

A

T

IO

N

P

Y

T P

M

B

W E

S T

O V

E R

A

IR

R E

S E

R V

E B

A S

E

M A

S S

A C

H U

S E

T T

S

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y M

O

(8

-9

R E

G

IO

N A

L I

S O

M A

IN

T

E N

A N

C E

H A

N G

A R

1A & 1B

KEY PLAN

BASE BID

/3

/2

:0

:4

P

M

/8

A-113

F L

O O

R P

L A

N

B

ID

O P

T

IO

N

B

M T

O L B

E R

T

E .T

O R

N E

D C

S

P R

IN

K

/0

/2

Y T

P M

B

A

C e n tr a l.

rv t

SCALE: 1/8" = 1'-0"A1

FLOOR PLAN - BID OPTION 1B N

0 4' 8' 16'

S Y

M

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

C

E R

T

IF

IE

D

F

IN

A L

/3 /2

A

M E

N D

M E

N T

/3

/2

W

2Q R

R

-0

GROUND FLOOR

100' - 0"

C3

A-356

A4

A-355

FLUID APPLIED AIR &

VAPOR BARRIER ON

8" NOM. CMU

RIGID INSULATION (R-12

MIN)

AIR SPACE

8" NOMINAL CMU

RE: STRUCTURAL

THERMAL BLOCK

CONTINUOUS

STAINLESS

STEEL FLASHING

110' - 0"

TOP OF CMU

TUBE STEEL GIRT

RE: STRUCTURAL

CONCRETE FLOOR SLAB

RE: STRUCTURAL

FINISH GRADE

RE: CIVIL

CONTINUOUS 5/8"

COVERBOARD

1 1/2" 1" 10"

UNFACED BATT METAL

BUILDING INSULATION

(R-20 MIN) FABRIC LINER SYSTEM

WITH R-20 MIN BATT

INSULATION

1' - 8"

EXPOSED FASTENER

CORRUGATED METAL

WALL PANEL SYSTEM

(MP-1)

HANGAR BAY

PRE-FINISHED

METAL FLASHING

WITH DRIP EDGE

FINISH TO MATCH

METAL PANEL

M E

T A

L P

A N

E L

F A

S T

E N

E R

S P

A C

IN

G

7/8" HAT CHANNEL

ATTACHED TO CONTINUOUS

COLD FORMED ANGLE

A S

R E

Q U

IR

E

D

Y

M A

N U

F A

C T

U R

E R

DAMP PROOFING

15 MIL VAPOR BARRIER TYP.

AT HANGAR BAY - RETURN

UP SLAB EDGE

24" CONTINUOUS

RIGID INSULATION

(R-15 MIN)

GROUND FLOOR

100' - 0"

N

C1

A-355

FLUID APPLIED AIR & VAPOR

BARRIER ON 8" NOM. CMU

RIGID INSULATION (R-12 MIN)

8" NOMINAL CMU

RE: STRUCTURAL

CONCRETE FLOOR SLAB

RE: STRUCTURAL

FINISH GRADE, RE: CIVIL

15 MIL VAPOR BARRIER

TYP. AT HANGAR BAY -

RETURN UP SLAB EDGE

ISOLATION STRIP

1' - 8"1' - 0 1/2"

GRANULAR FILL

AIR SPACE

1/16" / 1' - 0"

CONTINUOUS STAINLESS

STEEL FLASHING

PRE-FINISHED METAL FLASHING

WITH DRIP EDGE FINISH TO

MATCH METAL PANEL

EXPOSED FASTENER

CORRUGATED METAL WALL

PANEL SYSTEM (MP-1)

7/8" HAT CHANNEL ATTACHED

TO CONTINUOUS COLD

FORMED ANGLE

2 1/2"

8" NOM1 1/2"

7/8"

CONTINOUS SEALANT

6" M

IN

CONTINUOUS STAINLESS

STEEL FLASHING

CONTINUOUS 5/8"

COVERBOARD

DAMP PROOFING

24" CONTINUOUS

RIGID INSULATION

(R-15 MIN)

GROUND FLOOR

100' - 0"

SHOPS FLOOR BASE BID

99' - 0"

GRANULAR FILL

CONCRETE FLOOR SLAB

RE: STRUCTURAL

CONCRETE FLOOR SLAB

RE: STRUCTURAL

8" NOMINAL CMU

RE: STRUCTURAL

ISOLATION STRIPISOLATION STRIP

GRANULAR FILL

15 MIL VAPOR BARRIER

15 MIL VAPOR BARRIER

TYP. AT HANGAR BAY -

RETURN UP SLAB EDGE

CONTINOUS SEALANT

CONTINOUS SEALANT

GROUND FLOOR

100' - 0"

1' - 0 1/2"

FLUID APPLIED AIR & VAPOR

BARRIER ON 8" NOM. CMU

RIGID INSULATION (R-12 MIN)

8" NOMINAL CMU

RE: STRUCTURAL

CONCRETE FLOOR SLAB

RE: STRUCTURAL

15 MIL VAPOR BARRIER

TYP. AT HANGAR BAY -

RETURN UP SLAB EDGE

ISOLATION STRIP

GRANULAR FILL

AIR SPACE

A1

A-355

1 1/2" 8" NOM

2 1/2"

7/8"

PRE-FINISHED METAL FLASHING

WITH DRIP EDGE FINISH TO

MATCH METAL PANEL

EXPOSED FASTENER

CORRUGATED METAL WALL

PANEL SYSTEM (MP-1)

7/8" HAT CHANNEL

ATTACHED TO CONTINUOUS

COLD FORMED ANGLE

CONTINOUS SEALANT

6" M

IN

CONTINUOUS STAINLESS

STEEL FLASHING

FINISH GRADE

RE: CIVIL

CONTINUOUS 5/8"

COVERBOARD

DAMP PROOFING

24" CONTINUOUS RIGID

INSULATION (R-15 MIN)

GROUND FLOOR

100' - 0"

SHOPS FLOOR BASE BID

99' - 0"

FLUID APPLIED AIR & VAPOR

BARRIER ON 8" NOM. CMU

RIGID INSULATION

(R-12 MIN)

AIR SPACE

8" NOMINAL CMU

RE: STRUCTURAL

CONCRETE FLOOR SLAB

RE: STRUCTURAL

15 MIL VAPOR BARRIER

TYP. AT HANGAR BAY -

RETURN UP SLAB EDGE

ISOLATION STRIP

GRANULAR FILL

PRE-FINISHED METAL FLASHING

WITH DRIP EDGE FINISH TO

MATCH METAL PANEL

EXPOSED FASTENER

CORRUGATED METAL WALL

PANEL SYSTEM (MP-1)

7/8" HAT CHANNEL

ATTACHED TO CONTINUOUS

COLD FORMED ANGLE

1' - 0 1/2"

7 5/8"

2 1/2"

1 1/2" 7/8"

1/2" HAT CHANNEL

ATTACHED TO CONTINUOUS

COLD FORMED ANGLE

CONTINUOUS STAINLESS

STEEL FLASHING

FINISH GRADE

RE: CIVIL

CONTINUOUS 5/8"

COVERBOARD

DAMP PROOFING

24" CONTINUOUS

RIGID INSULATION

(R-15 MIN)

M

IN6"

D E

S

IG

N E

D B

Y

1 432

A

B

C

D

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S L O

U

IS

V

IL

L E

K

E N

T U

C K

Y D

W N

B Y

C

K D

B Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

D A

T E

P R

O J E

C T

N O

P

N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

A F

-2 -1

-0

CERTIFIED FINAL

S O

L

IC

IT

A

T

IO

Y

T P

M

W E

S T

O V

E R

A

IR

R E

S E

R V

E B

A S

E

M A

S S

A C

H U

S E

T T

S

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y M

O

(8

-9

R E

G

IO

N A

L I

S O

M A

IN

T

E N

A N

C E

H A

N G

A R

/3

/2

:0

:4

P

M

/2

A-351

S E

C T

IO

N

D E

T A

IL

S

M T

O L B

E R

T

E .T

O R

N E

D R

N

E D

D O

/0

/2

Y T

P M

B

A

C e n tr a l.

rv t

SCALE: 1 1/2" = 1'-0"A1

SECTION DETAIL

0 1/2' 1' 1 1/2'

SCALE: 1 1/2" = 1'-0"C2

WALL BASE DETAIL

SCALE: 1 1/2" = 1'-0"A4

WALL BASE DETAIL

SCALE: 1 1/2" = 1'-0"C4

WALL BASE DETAIL

SCALE: 1 1/2" = 1'-0"A2

WALL BASE DETAIL

0 1/2' 1' 1 1/2' 0 1/2' 1' 1 1/2'

0 1/2' 1' 1 1/2'

0 1/2' 1' 1 1/2'

S Y

M

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

C

E R

T

IF

IE

D

F

IN

A L

/3 /2

A

M E

N D

M E

N T

/3

/2

W

2Q R

R

-0

FRONT VIEW

TOP VIEW

6 1/4"

1/

4"

INSIDE

BODY: 5" x 6"

3" x 4"CLEANOUT

WITH NEOPRENE

GASKET

SIDE VIEW

3'

1'

3/ 4"

6 7/8" 2"

DOWNSPOUT

DOWNSPOUT BOOT

UNDERGROUND

DRAINAGE SYSTEM

RE: CIVIL

C3

A-461

3" x 4"CLEANOUT WITH

NEOPRENE GASKET

3'

24" CONTINUOUS

RIGID INSULATION

(R-15 MIN)

D E

S

IG

N E

D B

Y

1 432

A

B

C

D

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S L O

U

IS

V

IL

L E

K

E N

T U

C K

Y D

W N

B Y

C

K D

B Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

D A

T E

P R

O J E

C T

N O

P

N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

A F

-2 -1

-0

CERTIFIED FINAL

S O

L

IC

IT

A

T

IO

Y

T P

M

W E

S T

O V

E R

A

IR

R E

S E

R V

E B

A S

E

M A

S S

A C

H U

S E

T T

S

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y M

O

(8

-9

R E

G

IO

N A

L I

S O

M A

IN

T

E N

A N

C E

H A

N G

A R

/3

/2

:0

:4

P

M

/2

A-461

M

IS

C E

L L

A N

E O

U S

D E

T A

IL

S

M T

O L B

E R

T

E .T

O R

N E

D R

N

E D

D O

/0

/2

Y T

P M

B

A

C e n tr a l.

rv t

SCALE: 1 1/2" = 1'-0"C3

DOWNSPOUT BOOT DETAIL

SCALE: 1 1/2" = 1'-0"C4

DOWNSPOUT BOOT DETAIL

0 1/2' 1' 1 1/2' 0 1/2' 1' 1 1/2'

S Y

M

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

C

E R

T

IF

IE

D

F

IN

A L

/3 /2

A

M E

N D

M E

N T

/3

/2

W

2Q R

R

-0

NL

SCHEDULE

DOOR PER A

B

S C

H E

D U

L E

D O

O R

P E

R

D O

O R

P E

R S

C H

E D

U L E

SCHEDULE

DOOR PER

D O

O R

P E

R S

C H

E D

U L E

A D

B C

SCHEDULE

DOOR PER

OH

D O

O R

P E

R S

C H

E D

U L E

DOOR PER SCHEDULE

F1

HL

GLASS TYPES:

REFERENCE SPECIFICATION FOR GLASS TYPES

1 TYPE-1 FIRE/SAFETY GLASS (45 MIN)

2 TYPE-2 CLEAR LAMINATED GLASS

3 TYPE-3 TINTED / INSULATED GLASS,

LAMINATED INNER PANEL

4 NOT USED

5 NOT USED

6 NOT USED

24"

D E

S

IG

N E

D B

Y

1 432

A

B

C

D

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S L O

U

IS

V

IL

L E

K

E N

T U

C K

Y D

W N

B Y

C

K D

B Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

D A

T E

P R

O J E

C T

N O

P

N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

A F

-2 -1

-0

CERTIFIED FINAL

S O

L

IC

IT

A

T

IO

Y

T P

M

W E

S T

O V

E R

A

IR

R E

S E

R V

E B

A S

E

M A

S S

A C

H U

S E

T T

S

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y M

O

(8

-9

R E

G

IO

N A

L I

S O

M A

IN

T

E N

A N

C E

H A

N G

A R

/3

/2

:2

:1

P

M

/4

A-601

D O

O R

S C

H E

D U

L E

B

A S

E B

ID

D O

O R

A N

D F

R A

M E

T Y

P E

S

M T

O L B

E R

T

E .T

O R

N E

D C

S

P R

IN

K

/0

/2

Y T

P M

B

A

C e n tr a l.

rv t

DOOR SCHEDULE - BASE BID

DOOR

NUMBER

DOOR FRAME

ASSEMBLY

RATING STC

DETAIL

HARDWARE

SET REMARKS

SIZE

TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILL

PAIR

DOOR WIDTH HEIGHT

001A - 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 1.0

001B - 20' - 0" 16' - 0" OH-IN STL FF-1 0 STL FF-1 - - B1 / A-612 A2 / A-612 A1 / A-612 32.0

001C - 3' - 0" 7' - 0" F-IN HM PE-1 1.2 HM PE-1 3/4 HR - C4 / A-611 B1 / A-611 A1 / A-611 7.0

001D - 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 1.0

001E - 14' - 0" 14' - 0" OH-IN STL FF-1 0 STL FF-1 - - B1 / A-612 A2 / A-612 A1 / A-612 32.0

001G - 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 1.0

001H - 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 1.0

001K - 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 1.0

001L - 14' - 0" 14' - 0" OH-IN STL FF-1 0 STL FF-1 - - B1 / A-612 A2 / A-612 A1 / A-612 32.0

001M - 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 1.0

001N - 3' - 0" 7' - 0" NL-IN-R HM PE-1 1.2 HM PE-1 3/4 HR - C4 / A-611 B1 / A-611 A1 / A-611 7.0

002A - 9' - 4" 8' - 0" OH-IN STL FF-1 0 STL FF-1 - - B2 / A-613 A2 / A-612 A1 / A-612 32.0

002B - 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 3/4 HR - C4 / A-611 B1 / A-611 A1 / A-611 2.0

003A - 3' - 0" 7' - 0" F HM PE-1 1.1 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 30.0

004A - 3' - 0" 7' - 0" F HM PE-1 1.1 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 30.0

005A - 3' - 0" 7' - 0" F HM PE-1 1.1 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 22.0

007A - 3' - 0" 7' - 0" HL-IN HM PE-1 1.1 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 1.0

007B - 3' - 0" 7' - 0" NL HM PE-1 1.1 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 8.0

008A PR. 3' - 0" 7' - 0" F-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 6.0

010A - 3' - 0" 7' - 0" F HM PE-1 1.1 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 24.0

011A - 3' - 0" 7' - 0" NL-R HM PE-1 1.2 HM PE-1 3/4 HR - C2 / A-611 B2 / A-611 A2 / A-611 11.0

011B - 3' - 0" 7' - 0" NL HM PE-1 1.1 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 9.0

012A PR. 4' - 0" 9' - 0" F-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 5.0

012B PR. 3' - 0" 7' - 0" F-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 4.0

DOOR AND FRAME LEGEND

FINISH

FA** FIELD APPLIED COATING

FF* FACTORY FINISHED

MATERIAL

AL ALUMINUM

HM HOLLOW METAL

STL STEEL

SIZE

- SINGLE DOOR

PR PAIR OF DOORS

*REFERENCE DOOR OR FRAME SPECIFICATIONS

AND FINISH INFORMATION INDICATED IN DRAWINGS

A-201 THROUGH A-205.

**FIELD APPLY PER PAINT SPECIFICATION FOR

APPLICABLE SUBSTRATE AND EXPOSURE. INTERIOR

DOORS AND FRAMES: PAINT MATERIAL PA-4 AS

INDICATED IN DRAWINGS A-702. EXTERIOR DOORS

AND FRAMES: AS INDICATED IN DRAWINGS A-201

THROUGH A-205.

(DOOR FRAME)

TYPE A B

1.1 2" 2"

1.2 2" 4"

(FLUSH PANEL)

TYPE DESCRIPTION

F-IN FLUSH PANEL INSULATED

F FLUSH PANEL

(NARROW LIGHT)

TYPE DESCRIPTION A B C D #

NL NARROW LITE 6" 43" 24" 4" 2

NL-IN NARROW LITE INSULATED 6" 43" 24" 4" 3

NL-IN-R NARROW LITE INSULATED & RATED 6" 43" 24" 4" 1 & 3

NL-R NARROW LITE RATED 6" 43" 24" 4" 1

(OVERHEAD)

TYPE DESCRIPTION

OH-C COILING DOOR

OH-IN OVERHEAD INSULATED COILING DOOR

(HALF LIGHT/TRAFFIC)

TYPE DESCRIPTION A B C #

HL-IN HALF LITE INSULATED 6" 43" 35" 3

GENERAL NOTES:

REFER TO SPECIFICATION SECTION 08 71 00

FOR DOOR HARDWARE SET DEFINITIONS.

DOORS 001F & 001J NOT USED.

1.

2.

S Y

M

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

C

E R

T

IF

IE

D

F

IN

A L

/3 /2

A

M E

N D

M E

N T

/3

/2

W

2Q R

R

-0

NL

SCHEDULE

DOOR PER A

B

S C

H E

D U

L E

D O

O R

P E

R

D O

O R

P E

R S

C H

E D

U L E

SCHEDULE

DOOR PER

D O

O R

P E

R S

C H

E D

U L E

A D

B C

SCHEDULE

DOOR PER

OH

D O

O R

P E

R S

C H

E D

U L E

DOOR PER SCHEDULE

F1

HL

GLASS TYPES:

REFERENCE SPECIFICATION FOR GLASS TYPES

1 TYPE-1 FIRE/SAFETY GLASS (45 MIN)

2 TYPE-2 CLEAR LAMINATED GLASS

3 TYPE-3 TINTED / INSULATED GLASS,

LAMINATED INNER PANEL

4 NOT USED

5 NOT USED

6 NOT USED

24"

D E

S

IG

N E

D B

Y

1 432

A

B

C

D

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S L O

U

IS

V

IL

L E

K

E N

T U

C K

Y D

W N

B Y

C

K D

B Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

D A

T E

P R

O J E

C T

N O

P

N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

A F

-2 -1

-0

CERTIFIED FINAL

S O

L

IC

IT

A

T

IO

Y

T P

M

W E

S T

O V

E R

A

IR

R E

S E

R V

E B

A S

E

M A

S S

A C

H U

S E

T T

S

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y M

O

(8

-9

R E

G

IO

N A

L I

S O

M A

IN

T

E N

A N

C E

H A

N G

A R

/1

/2

:1

:2

A M

/4

A-602

D O

O R

S C

H E

D U

L E

B

ID

O

P T

IO

N

S

M T

O L B

E R

T

E .T

O R

N E

D C

S

P R

IN

K

/0

/2

Y T

P M

B

A

C e n tr a l.

rv t

DOOR SCHEDULE - BID OPTION 1A & 1B

DOOR FRAME

ASSEMBLY

RATING STC

DETAIL

HARDWARE

SET REMARKS

SIZE

TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILL

PAIR

DOOR WIDTH HEIGHT

101A - 3' - 0" 7' - 0" HL-IN HM PE-1 1.1 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 1.0

101B - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 9.0

102A PR. 3' - 0" 7' - 0" F HM PE-1 1.1 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 27.0

103A - 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 26.0

104A PR. 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 15.0

105A PR. 3' - 0" 7' - 0" F-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 4.0

106A - 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 21.0

107A - 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 2.0

107B - 8' - 0" 10' - 0" OH-IN STL FF-1 0 STL FF-1 - - B2 / A-613 A2 / A-612 A1 / A-612 32.0

107C PR. 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 3/4 HR - C3 / A-611 B3 / A-611 A3 / A-611 12.0

107D - 4' - 0" 7' - 0" NL HM PE-1 1.1 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 17.0

108A - 3' - 0" 7' - 0" NL-R HM PE-1 1.2 HM PE-1 3/4 HR - C3 / A-611 B3 / A-611 A3 / A-611 14.0

108B - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 16.0

110A - 12' - 0" 6' - 0" OH-C STL FF-1 0 STL FF-1 3/4 HR - C4 / A-613 B4 / A-613 A4 / A-613 32.0

110B - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 16.0

110C - 4' - 0" 7' - 0" NL HM PE-1 1.1 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 18.0

111A - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 8.0

112A - 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 29.0

113A - 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 29.0

114A PR. 3' - 0" 7' - 0" F-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 4.0

114B PR. 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 3/4 HR - C3 / A-611 B3 / A-611 A3 / A-611 13.0

115A PR. 3' - 0" 7' - 0" F-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 4.0

115B - 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 25.0

116A - 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 23.0

DOOR SCHEDULE - BID OPTION 2A & 2B

DOOR FRAME

ASSEMBLY

RATING STC

DETAIL

HARDWARE

SET REMARKS

SIZE

TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILL

PAIR

DOOR WIDTH HEIGHT

201A - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 20.0

202A - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 19.0

203A - 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 22.0

205A - 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 31.0

206A - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 8.0

206B - 3' - 0" 7' - 0" HL-IN HM PE-1 1.1 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 1.0

207A - 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 10.0

208A - 3' - 0" 7' - 0" F HM PE-1 1.1 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 31.0

209A - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 19.0

209B - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 20.0

210A - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 8.0

213A - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 8.0

213B - 3' - 0" 7' - 0" NL-R HM PE-1 1.2 HM PE-1 3/4 HR - C3 / A-611 B3 / A-611 A3 / A-611 14.0

214A - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 19.0

216A PR. 3' - 0" 7' - 0" F-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 4.0

217A - 3' - 0" 7' - 0" F HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 24.0

218A - 3' - 0" 7' - 0" F-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 3.0

219A - 3' - 0" 7' - 0" HL-IN HM PE-1 1.1 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 1.0

219B - 3' - 0" 7' - 0" NL HM PE-1 1.2 HM PE-1 - - C2 / A-611 B2 / A-611 A2 / A-611 8.0

DOOR SCHEDULE - BID OPTION 3A

DOOR FRAME

ASSEMBLY

RATING STC

DETAIL

HARDWARE

SET REMARKS

SIZE

TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILL

PAIR

DOOR WIDTH HEIGHT

301A - 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 - - C4 / A-611 B1 / A-611 A1 / A-611 2.0

301B - 3' - 0" 7' - 0" NL-R HM PE-1 1.2 HM PE-1 3/4 HR - C3 / A-611 B3 / A-611 A3 / A-611 14.0

301C 8' - 0" 8' - 0" OH-C STL FF-1 0 STL FF-1 3/4 HR - C4 / A-612 B4 / A-612 A4 / A-612 32.0

DOOR AND FRAME LEGEND

FINISH

FA** FIELD APPLIED COATING

FF* FACTORY FINISHED

MATERIAL

AL ALUMINUM

HM HOLLOW METAL

STL STEEL

SIZE

- SINGLE DOOR

PR PAIR OF DOORS

*REFERENCE DOOR OR FRAME SPECIFICATION

**FIELD APPLY PER PAINT SPECIFICATION FOR

APPLICABLE SUBSTRATE AND EXPOSURE.

(DOOR FRAME)

TYPE A B

1.1 2" 2"

1.2 2" 4"

(FLUSH PANEL)

TYPE DESCRIPTION

F-IN FLUSH PANEL INSULATED

F FLUSH PANEL

(NARROW LIGHT)

TYPE DESCRIPTION A B C D #

NL NARROW LITE 6" 43" 24" 4" 2

NL-IN NARROW LITE INSULATED 6" 43" 24" 4" 3

NL-IN-R NARROW LITE INSULATED & RATED 6" 43" 24" 4" 1 & 3

NL-R NARROW LITE RATED 6" 43" 24" 4" 1

NL-R NARROW LITE RATED 6" 43" 24" 4" 2

(OVERHEAD)

TYPE DESCRIPTION

OH-C COILING DOOR

OH-IN OVERHEAD INSULATED COILING DOOR

(HALF LIGHT/TRAFFIC)

TYPE DESCRIPTION A B C #

HL-IN HALF LITE INSULATED 6" 43" 35" 3

S Y

M

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

C

E R

T

IF

IE

D

F

IN

A L

/3 /2

A

M E

N D

M E

N T

/1

/2

A

M E

N D

M E

N T

/3

/2

W

2Q R

R

-0

STRUCT STEEL

RE: STRUCT DWGS

HANGAR DOOR LEAF

3" 1'

NEOPRENE WEATHER TIGHT

SEALS PROVIDED BY HANGAR

DOOR MANUFACTURER

2'

2'

/2

HANGAR DOORS

SHOWN IN OPEN

POSITION

FILL VOID WITH FOAM INSULATION

8" NOMINAL CMU

2" HAT CHANNEL

ATTACHED TO CMU

2'

/2

2 3/4" R-20 INSULATED

METAL PANEL (MP-2)

OUTSIDE CORNER TRIM

5" INSULATED METAL

WALL PANEL

CONTINUOUS 1/8" GALV. BENT

PLATE (PAINTED) W/ RECESSED

WALL ANCHORS 4'-0" O.C.

BLOCKING BEHIND

EACH WALL ANCHOR

GROUND FLOOR

100' - 0"

AB

HANGAR TRENCH

DOOR TRACK ELEV.

HANGAR DOORS

BEYOND

HANGAR DOOR IN SECTION

3' - 2 1/2"

5' - 2" 2' - 0"

3 3/4"

2' - 0"

3 3/4"

1' - 0" 9"

3"

2' - 2 1/2" 2' - 8 1/2"

STEEL PROVIDED

BY HANGAR DOOR

MANUFACTURER

6' - 2 1/2"

CORRUGATED METAL

PANEL SYSTEM

STRUCT STEEL

RE: STRUCT DWGS

METAL DRIP EDGE

FLUSH INSULATED

METAL SOFFIT PANEL

NOTES:

PROVIDE WEATHER STRIPPING AT

ALL SIDES OF DOOR LEAVES.

HANGAR SHALL BE WEATHER

TIGHT.

ALL DOOR DIMENSIONS TO BE

VERIFIED BY DOOR SUPPLIER.

1.

2.

STRUCT GIRT, TYP.

2 3/4" R-20 INSULATED

METAL PANEL (MP-2)

B3

A-623

T.O. OPENING

HANGING WEATHER

STRIPPING TYP., AT

FRONT & SIDE OF

HANGAR DOOR -

RE: SPECIFICATION

98' - 4"

173' - 3 1/4"

CORRUGATED METAL

PANEL SYSTEM

1/4" THICK GALVANIZED

STEEL PLATE WELDED

TO STRUCTURE

RE: STRUCTURAL

SEE CIVIL FOR PAVING

& JOINT INFORMATION

48" CONTINUOUS RIGID

INSULATION WITH

COMBINED HORIZONTAL

& VERTICAL (R-20 MIN)

CONCRETE AT HANGAR

DOORS AND TRENCH

RE: STRUCT DWGS

A

STRUCT STEEL

RE: STRUCT DWGS

HANGAR DOOR LEAF

3" 1'

NEOPRENE WEATHER TIGHT

SEALS PROVIDED BY HANGAR

DOOR MANUFACTURER

2'

2'

/2

HANGAR DOORS SHOWN

IN OPEN POSITION

MASONRY WALL

CORRUGATED METAL

PANEL SYSTEM

2'

/2

CORRUGATED METAL

PANEL - CORNER TRIM

2 3/4" R-20 INSULATED

METAL PANEL (MP-2)

RIGID INSULATION

(R-12 MIN)

ALIGN FACE OF 1/8" BENT

PLATE W/ MASONRY BELOW.

FILL CAVITY W/ INSULATION

CONTINUOUS 1/8" GALV. BENT

PLATE (PAINTED) W/ RECESSED

WALL ANCHORS 4'-0" O.C.

CORRUGATED METAL

PANEL SYSTEM

FLUID APPLIED AIR &

VAPOR BARRIER

BLOCKING BEHIND

EACH WALL ANCHOR

D E

S

IG

N E

D B

Y

1 432

A

B

C

D

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S L O

U

IS

V

IL

L E

K

E N

T U

C K

Y D

W N

B Y

C

K D

B Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

D A

T E

P R

O J E

C T

N O

P

N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

A F

-2 -1

-0

CERTIFIED FINAL

S O

L

IC

IT

A

T

IO

Y

T P

M

W E

S T

O V

E R

A

IR

R E

S E

R V

E B

A S

E

M A

S S

A C

H U

S E

T T

S

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y M

O

(8

-9

R E

G

IO

N A

L I

S O

M A

IN

T

E N

A N

C E

H A

N G

A R

/3

/2

:0

:4

P

M

A s i n d ic a te d

A-622

H A

N G

A R

D O

O R

D E

T A

IL

S

S

E C

T

IO

N

M T

O L B

E R

T

E .T

O R

N E

D C

S

P R

IN

K

/0

/2

Y T

P M

B

A

C e n tr a l.

rv t

SCALE: 1" = 1'-0"A1

HANGAR DOOR JAMB - CUT AT 4'-0" A.F.F. (MP4 BID OPTION)

N

0 1/2' 1' 2'

SCALE: 3/8" = 1'-0"A4

WALL SECTION AT HANGAR DOORS

0 2' 4' 6'

SCALE: 1" = 1'-0"C1

HANGAR DOOR JAMB - CUT AT 4'-0" A.F.F. (BASE BID)

N

0 1/2' 1' 2'

S Y

M

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

C

E R

T

IF

IE

D

F

IN

A L

/3 /2

A

M E

N D

M E

N T

/3

/2

W

2Q R

R

-0

GENERAL ROOM FINISH SCHEDULE NOTES:

REFER TO SPECIFICATIONS AND FINISH LEGEND FOR THE BASIS OF DESIGN OR EQUIVALENT

MANUFACTURER TECHNICAL REQUIREMENTS.

REFER TO INTERIOR ELEVATIONS, REFLECTED CEILING DRAWINGS, FLOOR FINISH DRAWINGS,

WALL FINISH DRAWINGS, ENLARGED PLAN DRAWINGS AND INTERIOR DETAIL DRAWINGS FOR

ADDITIONAL FINISH PLACEMENT INFORMATION.

REFER TO ELECTRICAL DRAWINGS, MECHANICAL DRAWINGS, STRUCTURAL DRAWINGS AND

COMMUNICATION DRAWINGS FOR COORDINATION OF BUILDING FINISHES TO BUILDING SYSTEMS.

REFER TO FLOORING TRANSITION DETAILS FOR TRANSITIONS BETWEEN ADJOINING FLOORING

MATERIALS.

REFER TO FINISH DRAWINGS AND INTERIOR ELEVATIONS FOR WALL FINISH EXTENTS, CORNER

GUARD LOCATIONS, SIGNAGE, AND SPECIALTY WALL FINISH LOCATIONS.

REFER TO REFLECTED CEILING DRAWINGS FOR CEILING HEIGHTS AND CEILING MATERIAL

EXTENTS.

REFER TO ENLARGED TOILET DRAWINGS, WALL FINISH PLANS AND INTERIOR ELEVATIONS FOR

PLACEMENT OF INTERIOR FINISHES IN TOILET/LOCKER ROOMS.

REFER TO MILLWORK DETAIL DRAWINGS AND INTERIOR ELEVATIONS FOR ASSIGNMENT OF SOLID

SURFACE AND PLASTIC LAMINATE FINISHES AND ADDITIONAL INFORMATION.

PROVIDE BLOCKING AS REQUIRED TO SECURE ALL WALL MOUNTED ITEMS INCLUDING TOILET

FIXTURES, TOILET ACCESSORIES, TOILET PARTITIONS, MILLWORK, SHELVES, COUNTERTOP

SUPPORTS, MARKERBOARDS, TACKBOARDS, FLAT PANEL DISPLAYS, CAMERAS, ACOUSTICAL WALL

PANELS, AND ANY OTHER WALL MOUNTED OBJECT.

UNLESS NOTED OTHERWISE, ALL EXPOSED STRUCTURAL STEEL TO BE PAINTED PA-5.

ALL WINDOW SILLS TO BE SSF-1.

UNLESS NOTED OTHERWISE, ALL EXTERIOR / PERIMETER

WINDOWS TO RECEIVE HB-1.

ALL DOOR FRAMES AND HOLLOW METAL DOORS TO BE PA-4.

ALL METAL FABRICATIONS AND HANDRAILS TO BE PA-4.

INTERIOR CAULKING TO MATCH ADJACENT WALL FINISH COLOR.

NO FINISHES REQUIRED ON CONCRETE WALLS OR CONCRETE CEILINGS UNLESS NOTED

OTHERWISE.

ALL EXPOSED CONCRETE FLOORS SHALL BE SEALED UNLESS NOTED OTHERWISE.

WALL CORNER GUARDS TO BE INSTALLED STARTING AT THE TOP OF THE SCHEDULED WALL BASE.

AT GYPSUM BOARD SOFFITS AND BULKHEADS, PAINT ALL EXPOSED SURFACES.

PAINT ALL EXPOSED STRUCTURAL STEEL ELEMENTS, MISCELLANEOUS STEEL, PIPING, HANGERS, VALVES AND CONDUITS EXCEPT PRE-FINISHED LINER PANELS AND FOAM GENERATORS. THE

PAINT COLOR SHALL BE AS INDICATED ON SCHEDULE. ALL FIRE PROTECTION PIPING COLOR SHALL

BE SAFETY RED.

ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND ASSOCIATED SUPPORTING

EQUIPMENT TO BE PAINTED PA-5 UNLESS OTHERWISE REQUIRED BY CODE. COORDINATE WITH

MECHANICAL / ELECTRICAL FOR FINISHES ON MECHANICAL OR ELECTRICAL EQUIPMENT.

DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL SURFACES, OPERATING PARTS, LABELS OR

WARNINGS.

REFER TO AND COORDINATE WITH FURNITURE DRAWINGS AND TYPICAL MOUNTING HEIGHTS

DRAWING FOR WALL MOUNTING HEIGHTS OF FF&E, VISUAL DISPLAYS AND AUDIO VISUAL

EQUIPMENT.

REFER TO SPECIFICATION 09 06 00 SCHEDULE OF FINISHES FOR EXTERIOR AND INTERIOR FINISH MATERIALS. BASIS OF DESIGN OR EQUIVALENT COLOR AND FINISH CODES ARE AS INDICATED ON

THE ROOM FINISH SCHEDULE.

FINISHES FOR BID OPTIONS 1A, 2A, 3A:

FLOORS: CONCRETE, UNFINISHED

WALLS: UNFINISHED

CEILINGS: EXPOSED TO STRUCTURE, UNFINISHED

DO NOT PAINT THE FABRIC LINER SYSTEM.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

1. BID OPTION: 5-COAT EPOXY COATING SYSTEM (EF-1)

2. BASE BID: ZINC-EPOXY PRIMER ON ALL EXPOSED AND NON-EXPOSED PRIMARY &

SECONDARY STEEL FRAMING.

RE: SPECIFICATION 09 97 13.27

BID OPTION: COAT EXPOSED AND NON-EXPOSED FERROUS METAL OF HANGAR

DOORS AND EXPOSED INTERIOR FERROUS METAL PRIMARY

AND SECONDARY STEEL FRAMING INSIDE AIRCRAFT MAINTENANCE BAYS.

RE: SPECIFICATION 09 97 13.27

ROOM FINISH SCHEDULE REMARKS:

D E

S

IG

N E

D B

Y

1 432

A

B

C

D

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

LOUISVILLE DISTRICT

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S L O

U

IS

V

IL

L E

K

E N

T U

C K

Y D

W N

B Y

C

K D

B Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

P

L O

T D

A T

E

D A

T E

P R

O J E

C T

N O

P

N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

A F

-2 -1

-0

CERTIFIED FINAL

S O

L

IC

IT

A

T

IO

Y

T P

M

W E

S T

O V

E R

A

IR

R E

S E

R V

E B

A S

E

M A

S S

A C

H U

S E

T T

S

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y M

O

(8

-9

R E

G

IO

N A

L I

S O

M A

IN

T

E N

A N

C E

H A

N G

A R

/3

/2

:0

:4

P

M

/8

A-701

R O

O M

F

IN

IS

H

S C

H E

D U

L E

R L A

S T

E R

E A

L L E

N R

L A

S T

E R

/0

/2

Y T

P M

B

A

C e n tr a l.

rv t

ROOM FINISH SCHEDULE - BASE BID

ROOM

NUMBER ROOM NAME FLOOR

BASE WALLS

CEILING REMARKSMATERIAL NORTH EAST SOUTH WEST

001 HANGAR BAY CS-1 - PA-1 PA-1 PA-1 PA-1 SEE "REMARKS" 1, 2

002 FIRE PROTECTION CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

003 MEN CSR-1 RB-1 FRP-1 / PE-1 FRP-1 / PE-1 FRP-1 / PE-1 PE-1 ACT-2

004 WOMEN CSR-1 RB-1 PE-1 FRP-1 / PE-1 PA-1 FRP-1 / PE-1 ACT-2

005 JAN CS-1 RB-1 FRP-1 / PE-1 FRP-1 PE-1 PE-1 PA-5

006 CORRIDOR CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

007 VEST WOM-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

008 ELEC CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

009 WASHER/DRYER CS-1 RB-1 - PA-1 PA-1 PA-1 PA-5

010 COMM CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

011 VEST CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

012 MECH CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

ROOM FINISH SCHEDULE - BID OPTION 1B

ROOM

NUMBER ROOM NAME FLOOR

BASE WALLS

CEILING REMARKSMATERIAL NORTH EAST SOUTH WEST

GROUND FLOOR

101 VEST WOM-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

102 ELEC CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

103 STORAGE CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

104 SANDING CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

105 MECH CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

106 OFFICE CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

107 SHEET METAL SHOP CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

108 BENCH STOCK CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

109 CORRIDOR CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

110 CTK TOOL CRIB CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

111 VEST CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

112 UNISEX CSR-1 RB-1 FRP-1 PE-1 PE-1 PE-1 ACT-2

113 UNISEX CSR-1 RB-1 FRP-1 PE-1 PE-1 PE-1 ACT-2

114 SATELLITE ACCUMULATION POINT CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

115 MSL - SECURE STORAGE CS-1 RB-1 PA-1 PA-1 PA-1 WM-1 PA-5

116 COMM CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

ROOM FINISH SCHEDULE - BID OPTION 2B

ROOM

NUMBER ROOM NAME FLOOR

BASE WALLS

CEILING REMARKSMATERIAL NORTH EAST SOUTH WEST

GROUND FLOOR

201 SUPER 1 CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

202 SUPER 2 CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

203 JAN CS-1 RB-1 FRP-1 / PE-1 PE-1 PE-1 FRP-1 / PE-1 PA-5

204 MENS SHOWER & LOCKERS CSR-1 RB-1 PA-1 / PE-1 FRP-1 / PE-1 FRP-1 / PE-1 / PA-1 FRP-1 / PE-1 / PA-1 ACT-2 / PA-5

205 MENS TOILET CSR-1 RB-1 PE-1 FRP-1 / PE-1 FRP-1 / PE-1 PE-1 ACT-2

206 VEST WOM-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

207 VEST CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

208 WOMENS TOILET / SHOWER & LOCKERS CSR-1 RB-1 PA-1 / PE-1 FRP-1 / PE-1 FRP-1 / PE-1 FRP-1 / PE-1 / PA-1 ACT-2 / PA-5

209 COORD. SHACK CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

210 VEST CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

211 CORRIDOR CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

212 READY ROOM / BREAK ROOM CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

213 VEST CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

214 CONF ROOM CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1

215 COMPUTER ROOM CS-1 RB-1 - PA-1 PA-1 PA-1 ACT-1

216 MECH CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

217 COMM CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

218 ELEC CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

219 VEST WOM-1 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5

S Y

M

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

C

E R

T

IF

IE

D

F

IN

A L

/3 /2

A

M E

N D

M E

N T

/3

/2

W

2Q R

R

-0

Sheets
A-113 - FLOOR PLAN - BID OPTION 1B
A-351 - SECTION DETAILS
A-461 - MISCELLANEOUS DETAILS
A-601 - DOOR SCHEDULE BASE BID. DOOR AND FRAME TYPES
A-602 - DOOR SCHEDULE - BID OPTIONS
A-622 - HANGAR DOOR DETAILS & SECTION
A-701 - ROOM FINISH SCHEDULE

File details come from the government source that posted it. Updated .