W912QR20B0018_AbramsCenterRenovation_Plans-0004.pdf

PDF 1 MB Posted

Attached to
SRM LIMA Cafeteria Renovation & SRM LIMA Abrams Center Renovation
Solicitation number
W912QR20B0018
Issued by

About this file

This solicitation package describes a firm-fixed-price construction contract opportunity with the U.S. Army Corps of Engineers to renovate cafeteria and conference facilities at the Joint Systems Manufacturing Center in Lima, Ohio. The solicitation will include renovating approximately 8,200 square feet to update the cafeteria, replace furnishings and equipment, install new audiovisual and ventilation systems, and refinish restrooms. For the conference area, the scope involves remodeling the entryway, removing partitions, adding furnishings, and mounting new audiovisual equipment. The contract duration is 360 calendar days. To be eligible, offerors must register in the System for Award Management and Joint Certification Program and provide proof of U.S. ownership and citizenship. The selection will be a sealed bid based on lowest price for a small business set-aside contract. The solicitation is anticipated to be between $1,000,000 and $5,000,000 and will be posted on beta.SAM.gov with no paper copies issued. The point of contact is listed for any questions.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

/4

/8

/4

/8

/4

2' - 8"

7' - 0 1/2"

/8

3' - 4"

4' - 0" 10' - 8" 8' - 3 1/2"

7' - 0"

13' - 8"

11' - 0"

20 2

/4

15 15

4' - 0"

2' - 8"

40' - 5 3/4"

INDICATES ITEMS TO REMAIN

INDICATES ITEMS TO BE DEMOLISHED

REMOVE EXISTING DOOR AND FRAME

SHEET ID

1 2 6 7

D R

A W

N B

Y

D E

S

IG

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

US Army Corps of Engineers ®

A N

S I D

F

A

C A

T E

G O

R Y

C O

D E

3 4 5 8 9 10

G

E

D

C

B

L

IM

A O

H

IO

L

IM

A S

R M

P R

O J E

C T

S A

B R

A M

S C

E N

T E

R R

E N

O V

A T

IO

N

P

J U

N E

W

Q

R

B

K B

L A

N F

O R

D

J C

O R

N E

L

IU

S

W F

O Y

AD110

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A M

C C

O Y

D E

M O

L

IT

IO

N

F L O

O R

P L A

N

J O

IN

T

S Y

S T

E M

S M

A N

U F

A C

T U

R

IN

G C

E N

T E

R

A D

CERTIFIED FINAL

SCALE: 1/4" = 1'-0"

DEMOLITION FLOOR PLAN

SHEET KEYNOTES

1 REMOVE EXISTING WOOD DOOR, DOOR FRAME, AND

ASSOCIATED HARDWARE.

2 REMOVE EXISTING CMU WALL AS INDICATED.

3 REMOVE EXISTING CASEWORK.

4 REMOVE EXISTING VANITY COUNTER AND LAVATORIES.

5 REMOVE WATER CLOSET, LAVATORY, AND URINALS.

REFER TO PLUMBING DRAWINGS.

6 REMOVE JANITOR'S SINK. REFER TO PLUMBING

DRAWINGS.

7 REMOVE WATER COOLER. REFER TO PLUMBING

DRAWINGS.

8 REMOVE ALL TOILET PARTITIONS AND URINAL SCREENS.

9 REMOVE ALL TOILET ACCESSORIES.

10 CONTRACTOR TO REMOVE AND DISPOSE OPERABLE

PARTITION AND ASSOCIATED HARDWARE.

11 REMOVE ACT CEILING.

12 REMOVE VCT FLOOR FINISH AND BASE.

13 CONTRACTOR SHALL INCLUDE THE REMOVAL OF THE

FOLLOWING FURNITURE: APPROXIMATELY 11 (8') LONG

FOLD UP TABLES, 75 STACKABLE CHAIRS, AND 1 DESK.

14 REMOVE PORTION OF MASONRY PLANTERS AS

INDICATED.

15 REMOVE CAP AND BRICK VENEER. MASONRY BACKUP TO

REMAIN.

16 REMOVE PREDECORATED GYPSUM BOARD AND

ASSOCIATED TRIM. FRAMING TO REMAIN.

17 REMOVE WINDOW BLINDS. 3 ARE IN CONFERENCE ROOM.

2 ARE IN OFFICE AREA.

18 REMOVE STOREFRONT ENTRANCE.

19 REMOVE EXISTING DOWNSPOUT AND BOOT.

20 REMOVE EXISTING GYP ON MTL STUD WALL AS

INDICATED.

21 REMOVE CARPET FLOOR FINISH AND BASE.

22 REMOVE EXISTING HOLLOW METAL DOOR, DOOR FRAME,

AND ASSOCIATED HARDWARE.

4' 02' 8' 12'4'

GRAPHIC SCALE: = 1'-0"¼"

GENERAL SHEET NOTES

1 REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL

DRAWINGS FOR STRUCTURAL, MECHANICAL, AND

ELECTRICAL DEMOLITION.

2 CONTRACTOR IS RESPONSIBLE FOR MAINTAINING

SAFETY AND CLEANLINESS. DUST IS TO BE SWEPT UP

AND DEBRIS IS TO BE REMOVED AT THE END OF EACH

DAY.

3 VERIFY ALL SURROUNDINGS AND CONCEALED ITEMS

PRIOR TO DEMOLITION. ALL ITEMS DAMAGED DURING

DEMOLITION THAT ARE TO REMAIN WILL BE THE

RESPONSIBILITY OF THE CONTRACTOR TO BE REPLACED

OR REPAIRED TO THE ORIGINAL STATE.

4 COORDINATE DEMOLITION WITH NEW WORK.

5 PATCH AND PREP ALL AREAS OF DEMOLITION AS

REQUIRED FOR NEW WORK.

6 CONTRACTOR WILL NEED TO GET PERMISSION FROM THE

PROPERTY DEPARTMENT BEFORE DISCARDING TAGGED,

GOVERNMENT OWNED PROPERTY. IF NOT TAGGED AS

GOVERNMENT PROPERTY IT CAN BE DISPOSED OF.

LEGEND

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

/2

/2

A

M E

N D

M E

N T

/8

/2

W

2Q R

B0

8-

VESTIBULE101

LOBBY

RECEPTION

CONFERENCE

ROOM

STORAGE

A/V CLOSET

JANITOR 107

MECHANICAL

MEN'S RESTROOM

WOMEN'S

RESTROOM

E02

M03

I04

E01

E02

M03

I03

M04

I02

I05 I06

M01 M04

M04 M02

E01

E01

M03

I01

I07

I07

I07

I07

SHEET ID

1 2 6 7

D R

A W

N B

Y

D E

S

IG

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

US Army Corps of Engineers ®

A N

S I D

F

A

C A

T E

G O

R Y

C O

D E

3 4 5 8 9 10

G

E

D

C

B

L

IM

A O

H

IO

L

IM

A S

R M

P R

O J E

C T

S A

B R

A M

S C

E N

T E

R R

E N

O V

A T

IO

N

P

J U

N E

W

Q

R

B

W K

IR

K

P A

T R

IC

K

K R

IG

G

S

W F

O Y

A-180

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

E W

IL

S

O N

S

IG

N A

G E

P L A

N

J O

IN

T

S Y

S T

E M

S M

A N

U F

A C

T U

R

IN

G C

E N

T E

R

A -1

CERTIFIED FINAL

SCALE: 1/4" = 1'-0"

SIGNAGE PLAN

4' 02' 8' 12'4'

GRAPHIC SCALE: = 1'-0"¼"

GENERAL SHEET NOTES

1 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS PRIOR TO PERFORMING NEW

CONSTRUCTION.

2 CONTRACTOR SHALL PATCH ALL AREAS DAMAGED

DURING DEMOLITION IN PREPERATION FOR NEW

CONSTRUCTION.

3 COORDINATE ALL NEW STRUCTURAL, MECHANICAL, AND

ELECTRICAL COMPONENTS PRIOR TO CONSTRUCTION.

REFER TO ALL STRUCTURAL, MECHANICAL, AND

ELECTRICAL DRAWINGS.

4 VERIFY ALL SURROUNDING AND CONCEALED ITEMS

PRIOR TO CONSTRUCTION. ALL ITEMS DAMAGED DURING

CONSTRUCTION THAT ARE TO REMAIN WILL BE THE

RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR

REPLACE TO THE ORIGINAL STATE.

5 IN STUD WALLS TYPICAL DOORS SHALL BE LOCATED 4"

FROM THE NEAREST WALL UNLESS OTHERWISE

INDICATED.

6 CONTRACTORS ARE FREE TO USE ANY PRODUCT WHICH

MEETS THE GOVERNMENT'S MINIMUM REQUIREMENTS

AND NOT IN CONFLICT WITH OTHER CONTRACT

PROVISIONS. UNLESS INDICATED OTHERWISE ON THE

PLANS OR SPECIFICATIONS (E.G. SOLE-SOURCE), ALL

LISTED MANUFACTURERS ARE THE BASIS OF DESIGN.

FOR THESE BASIS OF DESIGN PRODUCTS, OTHER

MANUFACTURERES MAY BE SUBSTITUTED AS LONG AS

THE STANDARD OF QUALITY AND CHARACTERISTICS OF

THE SUBSTITUTED MANUFACTURER MEET OR EXCEED

THE STANDARD OF QUALITY AND CHARACTERISTICS OF

THE BASIS OF DESIGN.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

/8

/2

W

2Q R

B0

8-

2' - 0"

1' - 9 3/4"

3/4"

1 1/2"

EXTEND STUDS TO UNDERSIDE

OF DECK AND SEAL

3 5/8" METAL STUD AT 16" O.C.

ACOUSTICAL SOUND BATT INSULATION

5/8" CEMENT BACKER BOARD (TYP.)

MIRROR. REFER TO

ELEVATIONS FOR SIZE

SOLID SURFACE COUNTER TOP

WITH 4" BACK SPLASH AT 3 SIDES

3/4" PLYWOOD

SOLID SURFACE APRON WITH

WOOD BLOCKING

SUSPENDED FIBERGLASS

MOISTURE RESISTANT

ACT CEILING.

5/8" WATER RESISTANT GYPSUM

BOARD.

A-412

A-412

MIRROR

5/8" CEMENTITIOUS

BACKER BOARD

STAINLESS STEEL

MIRROR FRAME

PROVIDE POST-KILN

DRIED TREATED

WOOD BLOCKING

METAL STUDS AT

16" O.C. (REFER TO

WALL TYPES FOR

SIZE OF STUDS)

SOLID SURFACING

BACKSPLASH

3/4" PLYWOOD

2' - 0"

2' - 0"

/4

EDGE OF TILE

BEHIND ACCESS

PANEL

ACCESS PANEL

ANCHORS (TYP.)

ANCHOR (TYP.)

ACCESS PANEL

SOUND BATT INSULATION

5/8" CEMENTITIOUS

BACKER BOARD

METAL STUDS AT

16" O.C. (REFER TO

WALL TYPES FOR

SIZE OF STUDS)

CERAMIC TILE,

REFER TO FINISH

SCHEDULE

WOOD BLOCKING

(BEYOND)

CERAMIC TILE

(BEYOND)

2"x4" POST-KILN

DRIED TREATED

WOOD BLOCKING

SOUND BATT

INSULATION

METAL STUDS AT 16" O.C.,

REFER TO PLANS FOR

WALL

TYPE

CEILING HEIGHT

EL.=108'-0"

SOFFIT HEIGHT

EL.=107'-6"

WALL TILE, REFER

TO FINISH SCHEDULE

3 5/8" METAL

STUDS AT 16" O.C.

SUSPENDED

FIBERGLASS MOISTURE

RESISTANT ACT

CEILING

5/8" CEMENT BOARD

WATER RESISTANT

GYPSUM BOARD

CEILING

SHEET ID

1 2 6 7

D R

A W

N B

Y

D E

S

IG

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

US Army Corps of Engineers ®

A N

S I D

F

A

C A

T E

G O

R Y

C O

D E

3 4 5 8 9 10

G

E

D

C

B

L

IM

A O

H

IO

L

IM

A S

R M

P R

O J E

C T

S A

B R

A M

S C

E N

T E

R R

E N

O V

A T

IO

N

P

J U

N E

W

Q

R

B

K B

L A

N F

O R

D

J .C

O R

N E

L

IU

S

W F

O Y

A-412

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A M

C C

O Y

R E

S T

R O

O M

C

E

IL

IN

G

D E

T A

IL

S

J O

IN

T

S Y

S T

E M

S M

A N

U F

A C

T U

R

IN

G C

E N

T E

R

A A

-4

CERTIFIED FINAL

SCALE: 1/2" = 1'-0"A-412

1 SECTION

SCALE: 3" = 1'-0"A-412

2 BLOCKING DETAIL

SCALE: 1/2" = 1'-0"A-412

3 MIRROR DETAIL

SCALE: 1" = 1'-0"A-412

4 RESTROOM ACCESS PANEL DETAIL

SCALE: 3" = 1'-0"A-412

5 RESTROOM ACCESS PANEL SECTION

GRAPHIC SCALE: = 1'-0"

4" 2" 0 4" 8" 1'

3"

GRAPHIC SCALE: = 1'-0"

1' 06" 2' 3'1'

1"

GRAPHIC SCALE: = 1'-0"

2' 01' 4' 6'2'

½"

SCALE: 1" = 1'-0"A-412

6 SOFFIT DETAIL

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

/8

/2

W

2Q R

B0

8-

PANEL COLOR:

701 DARK NEUTRAL

HELVETICA MEDIUM NUMBERS

COLOR: 708 WHITE

NOTE: COORDINATE WITH CONTRACTING OFFICE AND DPW

TO MATCH BASE STANDARDS.

1' - 8"

"XXXX

RED CIRCLE

WITH RED

DIAGONAL

BAR

PANEL COLOR:

701 DARK NEUTRAL

WHITE

BACKGROUND

BLACK

SYMBOL

6"

1/2" 5" 1/2"

/2

/2

Fire Team Leaders

9"

HELVETICA MEDIUM

NUMBERS

COLOR: 708 WHITE

GRADE TWO BRAILLE

COLOR: 708 WHITE

HELVETICA MEDIUM

UPPER AND LOWER

CASE LETTERS

EXAMPLE TEXT

PERMANENT HEADER PANEL

COLOR: 701 DARK NEUTRAL

CLEAR SLEEVE ACCEPTS A

PAPER OR PLASTIC INSERT

FOR OCCUPANT NAME. INSERT

WILL ACCOMMODATE FOUR

LINES WITH A MAXIMUM OF 21

CHARACTERS PER LINE.

1/2" 8" 1/2"

/2

/2

/1

/1

/8

"1 /2

/2

/8

Squad Leaders

HELVETICA MEDIUM

NUMBERS AND LETTERS

3" NUMBER

1/8" RULE WHITE TAPE

CAP

1' - 6"

/2

/2

/2

/2

CAP

CAP

Electrical Room

NOTE: COORDINATE WITH CONTRACTING OFFICE AND DPW

TO MATCH BASE STANDARDS.

1" 1' - 4" 1"

6"

5"1/2" 1/2"

/2

WOMEN

BLACK SYMBOL

WHITE BACKGROUND

PANEL COLOR:

701 DARK NEUTRAL

MESSAGE LINE WILL

ACCOMMODATE A

MAXIMUM OF SEVEN TILES

HELVETICA MEDIUM

CAPITAL LETTERS

GRADE TWO BRAILLE

COLOR: 708 WHITE

/4

/8

/8

1' - 0"

11 1/2"

IN CASE OF FIRE,

DO NOT USE ELEVATOR.

USE EXITS STAIRS UNLESS

OTHERWISE INSTRUCTED.

5/8" (16mm) MESSAGE TEXT

HELVETICA MEDIUM

55 ROMAN

REPLACEABLE EVACUATION

MAP

EXIT STAIR IDENTIFICATION

SIGN WITH PICTOGRAM

1. INDICATES SIGN NUMBER

2. REFER TO SIGNAGE SCHEDULE AND SIGNAGE

DETAILS ON SHEET.

3. SIGNAGE IS BASED ON 2/90 SIGNAGE SYSTEMS

TO ESTABLISH COLOR, PATTERN AND FINISH

ONLY AND IS NOT INTENDED TO LIMIT THE

SELECTIONS FROM OTHER

MANUFACTURERES.

4. ROOM NUMBERS AND TEST OF ALL SIGNS

SHALL BE VERIFIED AND CORRDINATED WITH

CONTRACTING OFFICER'S REPRESENTATIVE.

SHEET ID

1 2 6 7

D R

A W

N B

Y

D E

S

IG

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

US Army Corps of Engineers ®

A N

S I D

F

A

C A

T E

G O

R Y

C O

D E

3 4 5 8 9 10

G

E

D

C

B

L

IM

A O

H

IO

L

IM

A S

R M

P R

O J E

C T

S A

B R

A M

S C

E N

T E

R R

E N

O V

A T

IO

N

P

J U

N E

W

Q

R

B

W K

IR

K

P A

T R

IC

K

K R

IG

G

S

W F

O Y

A-620

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

E W

IL

S

O N

S

IG

N A

G E

S C

H E

D U

L E

A N

D S

IG

N

A G

E K

E Y

J O

IN

T

S Y

S T

E M

S M

A N

U F

A C

T U

R

IN

G C

E N

T E

R

A -6

CERTIFIED FINAL

SCALE: 3" = 1'-0"A-620

6 SIGN TYPE "BB13" DETAIL

SCALE: 3" = 1'-0"A-620

7 SIGN TYPE "DD1" DETAIL

SCALE: 3" = 1'-0"A-620

3 SIGN TYPE "BB2" DETAIL

SCALE: 3" = 1'-0"A-620

4 SIGN TYPE "B4" DETAIL (EXTERIOR TYPE)

SCALE: 3" = 1'-0"A-620

5 SIGN TYPE "BB7"

INTERIOR SIGNAGE

SIGN TAG SIGNAGE ROOM NO. SIGNAGE NAME SIGN TYPE

I01 101 LOBBY BB2

CONFERENCE ROOM

STORAGE

JANITOR

MECHANICAL

I02

I03

I04

I05

I06

COMMUNICATION

BB2

BB2

BB2

BB2

BB2

MISCELLANEOUS SIGNAGE

SIGN TAG SIGNAGE ROOM NO. SIGNAGE NAME SIGN TYPE

M01 108 MENS RESTROOM BB7

WOMENS RESTROOM

NO SMOKING

M02

M03

EVACUATION SIGN

(TO FIT 11" x 17"

PRINTED PAPER)

BB7

DD1

BB10

EXTERIOR SIGNAGE

SIGN TAG SIGNAGE ROOM NO. SIGNAGE NAME SIGN TYPE

BB13

CONFERENCE ROOM103 B4

E01

E02

M04 - - -

VERIFY LOCATION & TEXT

WITH CONTRACTING

OFFICE

BUILDING #

SCALE: 3" = 1'-0"A-620

1 SIGN TYPE "BB10" DETAIL

GRAPHIC SCALE: = 1'-0"

4" 2" 0 4" 8" 1'

3"

SIGNAGE PLAN NOTES

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

/8

/2

I07 EXIT--- BB3

SCALE: 3" = 1'-0"A-620

2 SIGN TYPE "BB3" DETAIL1

W

2Q R

B0

8-

3" SA

3" SA

(E)4" SA

3" SA

4" SA

3" SA

3 3

4" SA

SHEET ID

1 2 6 7

D R

A W

N B

Y

D E

S

IG

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

US Army Corps of Engineers ®

A N

S I D

F

A

C A

T E

G O

R Y

C O

D E

3 4 5 8 9 10

G

E

D

C

B

L

IM

A O

H

IO

L

IM

A S

R M

P R

O J E

C T

S A

B R

A M

S C

E N

T E

R R

E N

O V

A T

IO

N

P

J U

N E

W

Q

R

B

B O

IS

T

E N

B O

IS

T

E N

W F

O Y

PP101

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

T C

A P

E C

E P

L U

M B

IN

G

U N

D E

R G

R O

U N

D

J O

IN

T

S Y

S T

E M

S M

A N

U F

A C

T U

R

IN

G C

E N

T E

R

P P

CERTIFIED FINAL

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

D D

E N

D M

E N

T

/2

/2

GENERAL SHEET NOTES

1 REFER TO P-001 FOR LEGEND AND GENERAL

NOTES.

SHEET KEYNOTES

1 EXISTING 1-1/2"CW UP.

2 EXISTING 1-1/2" DOMESTIC WATER.

3 2"SA UP.

4 2"V UP.

5 3"SA P-TRAP UP TO FD.

6 3"SA UP TO FCO.

7 3"SA UP.

8 4"SA UP.

9 CONNECT 4" SANITARY WASTE PIPE TO EXISTING

SANITARY WASTE MAIN BELOW GRADE.

4' 02' 8' 12'4'

GRAPHIC SCALE: = 1'-0"¼"

SCALE: 1/4" = 1'-0"

UNDERGROUND PLUMBING PLAN

W

2Q R

B0

8-

MECHANICAL

MEN'S RESTROOM

WOMEN'S

RESTROOM

VESTIBULE

LOBBY

CONFERENCE

ROOM

STORAGE

A/V CLOSET

RECEPTION

JANITOR

WC-1A

LA-1A UR-1A

EWC-1A

SK-1

TMV-1

ET-1

RCP-1

MB-1

WH-1

WH-1

WH-1

HB-1

WC-1

WC-1A

WH-1

3/4" CW

3/4" CW

3/4" CW

3/4" CW

3/4" HW(110)

3/4" CW

1 1/2" CW

1/2" HW(110)

1/2" HWR(110)

1 1/2" CW

3/4" HW(110)

1/2" HWR(110)

1" CW

1" CW

EWH-1

1 1/2" CW

LA-1A

1/2" HWR(110)

1/2" HWR(110)

1/2" HW(110)

3/4" CW

RPZ-1

LA-1A

LA-1A

P-561

BALANCING VALVE

SET AT 0.5 GPM

BALANCING VALVE

SET AT 0.5 GPM

WHA-A

WHA-A

WHA-A

SHEET ID

1 2 6 7

D R

A W

N B

Y

D E

S

IG

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

US Army Corps of Engineers ®

A N

S I D

F

A

C A

T E

G O

R Y

C O

D E

3 4 5 8 9 10

G

E

D

C

B

L

IM

A O

H

IO

L

IM

A S

R M

P R

O J E

C T

S A

B R

A M

S C

E N

T E

R R

E N

O V

A T

IO

N

P

J U

N E

W

Q

R

B

B O

IS

T

E N

B O

IS

T

E N

W F

O Y

PP112

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

T C

A P

E C

E W

A T

E R

P L A

N

J O

IN

T

S Y

S T

E M

S M

A N

U F

A C

T U

R

IN

G C

E N

T E

R

P P

CERTIFIED FINAL

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

D D

E N

D M

E N

T

/2

/2

GENERAL SHEET NOTES

1 REFER TO P-001 FOR LEGEND AND GENERAL

NOTES.

SHEET KEYNOTES

1 1-1/2"CW DN. CONNECT TO EXISTING 1 1/2" CW IN

THIS AREA.

SCALE: 1/4" = 1'-0"

WATER PLAN

4' 02' 8' 12'4'

GRAPHIC SCALE: = 1'-0"¼"

W

2Q R

B0

8-

AD110
LIMA-ABRM-ARC_RiggsKE
AD110 - DEMOLITION FLOOR PLAN
A-180
LIMA-ABRM-ARC_RiggsKE
A-180 - SIGNAGE PLAN
A-412
LIMA-ABRM-ARC_RiggsKE
A-412 - RESTROOM & CEILING DETAILS
A-620
LIMA-ABRM-ARC_RiggsKE
A-620 - SIGNAGE SCHEDULE AND SIGNAGE KEY
PP101
PP112

File details come from the government source that posted it. Updated .