A22 - AMD 0001 - ME_Fire Inspection and Certificate_2024.pdf
PDF 3 MB Posted
- Attached to
- DREDGE MERRITT – SHIPYARD REPAIR SERVICES
- Solicitation number
- W912PM24Q0045
About this file
This document is a combined synopsis/solicitation for a federal contract opportunity to provide shipyard repair services for the Dredge Merritt. The Department of the Army Corps of Engineers Engineering District Wilmington is seeking labor, materials, and services to accomplish repairs, maintenance, and modifications while the vessel is dry-docked for up to 90 days.
The solicitation is issued as a Request for Quote (RFQ) under a small business set-aside with a NAICS code of 336611 (Ship Building and Repairing). Quotes are due by 2:00 PM ET on October 22, 2024, and must include a price quote and technical proposal detailing offerors' relevant past experience. A site visit is scheduled for September 30, 2024. The resulting award will be made to the lowest priced, technically acceptable offeror. Wage determinations will be based on the contractor's place of performance.
View the file
Other files
Show 40 more
Latest 50 of 78 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
Job #: Date:
IMO #: 100% Complete: Yes No
Qty Qty Qty
PORTABLE FIRE EXTINGUISHERS GALLEY HOOD SYSTEM DAMAGE CONTROL LOCKER
CO2 LOW PRESSURE SYSTEM FIRE DETECTION SYSTEM DRY CHEMICAL SYSTEM
CO2 HIGH PRESSURE SYSTEM S.C.B.A. EQUIPMENT MEDICAL O2 EQUIPMENT
HALON/CLEAN AGENT SYSTEM S.C.B.A. COMPRESSOR IMMERSION SUITS
FOAM SYSTEM/FOAM ANALYSIS E.E.B.D. EQUIPMENT FIRE HOSES
FIRE STATION INVENTORY GAS DETECTION SYSTEM WATER MIST SYSTEM
MISCELLANEOUS
Print Date
CERTIFICATE OF INSPECTION
Customer:
Flag / Classification:
Vessel:
Customer Signature
(when applicable)
Hiller Tech Signature
AHJ Signature
The Hiller Companies (and its divisions) herby certifies that the equipment specified below has been inspected, serviced and/or repaired on the date signed. The Hiller Companies
(and all its divisions) does not assume responsibility for the proper functioning of the systems following date of inspection.
THIS IS TO CERTIFY THAT THE EQUIPMENT DESCRIBED HEREIN HAS BEEN INSPECTED AND/OR TESTED AS
REQUIRED IN ACCORDANCE WITH APPLICABLE CODE AND MANUFACTURER RECOMMENDATIONS.
MCOI.XX.XX.01.001
US Army Corps of Engineers 33980147 4/4/2024
USCG ✔
USACE Merritt
✔ 19
✔ 1
✔ 2
4/4/2024
Matt Maniak 4/4/2024
4/4/2024
ST Job #: Service Tech:
System ID: Date:
MS - Manual Fire Boxes HD - Heat Detector B - Bell S - Strobe
H-MS - Halon Manual Station PD - Photo Electric Detector H - Horn PS - Pressure Switch
DSD - Duct Smoke Detector ID - Ionization Detector HS - Horn Strobe
GD - Gas Detector FD - Flame Detector SPK - Speaker
Serial # Location Description Address Manufacturer Device Type Pass Fail Comments
Device Type Abbreviations:
ALARM & DETECTION DEVICE TESTED
MDDT.XX.XX.01.001
Hiller 1242 Executive Boulevard
Chesapeake VA 23320
(757) 549-9123 hillerfire.com
33980147 Matt Maniak engine monitor inc 4/4/2024 engine room HD ✔ pump room HD ✔ pump room HD ✔ galley ID ✔ berthing ID ✔ berthing ID ✔ wheelhouse ID ✔
Location:
Qty of Cylinders: Cylinder Capacity:
Qty of Pilot Cylinders: Cylinder Capacity:
Carried Out Satisfactory Yes No Yes No N/A
7. Checked operation of pressure switch(es)? Quantity: Yes No Yes No N/A
11. Checked other shutdowns? Specify: Yes No Yes No N/A
Set Time: Actual Time:
Quantity: Yes No Yes No N/A
Electric Pneumatic
Room Temperature:
CYLINDERS (additional cylinders to be listed on following supplement, if applicable):
Serial # Manufacturer Stamped
Empty
Full
Required
Agent
Actual
Temperature
°C/°F PSI/BAR Last Hydro
Date Next
Hydro Due
Technician: Date:
Manufacturer:
Space Protected:
19. Checked labeling of system components?
20. Is system sealed and inspection tag attached?
21. Is system armed and ready for use?
9. Checked damper operation?
13. Checked operation of alarms?
15. Checked operation of visual indication?
16. Checked operation of stop valves?
14. Type of Alarms
10. Checked fuel oil pump shutdown?
12. Time Delay
COMMENTS: ANY REMARKS plus EXPLAIN ANY NO Answers
I state that the information on this form is correct at the time and place of the inspection, and that all equipment tested at this time was left in operational condition upon completion of this inspection except as noted in Comments section above.
Customer Name:
17. Checked operation of remote stations?
18. Checked operation of heat actuation?
3. Condition of cylinders (Satisfactory/Unsatisfactory)?
4. Checked for manufacturer recalls?
5. Checked lever/pressure actuation?
6. Checked condition of flex hoses?
8. Checked ventalation shutdown?
GENERAL REQUIREMENTS
1. Disconnect releasing mechanisms?
2. Contents in cylinders checked by weight/ liquid level?
Information on this form covers the minimum requirements of the current edition of 46CFR, appropriate classification requirements, as well as the latest version of the OEM manual (unless otherwise directed by the authority having jurisdiction).
SYSTEM INFORMATION
INSPECTION OF FIXED SUPPRESSION SYSTEM
Service Tech:
Dates of Service
ST Job #:
Vessel Name:
Comments
Technician Information
MFSS.46CFR.XX.01.001
Merritt 4/4/2024 US Army Corps of Engineers Kidde CO2 Room Engine Room
6 50 2 50
1 ✔ ✔
N/A ✔ ✔ 30 30
0 ✔ ✔ 0 ✔ ✔ 2 ✔ ✔
1497853 kidde 122 172 co2 172 7/18 7/30 72383 kidde 123 173 co2 173 7/18 7/30 49484 kidde 100 150 co2 150 7/18 7/30 24369 kidde 115 165 co2 165 7/18 7/30 84103 kidde 119 169 co2 169 7/18 7/30 61026 kidde 98 148 co2 148 7/18 7/30
System was tested with a 35LB CO2 cylinder
Andrew Johnson 4/4/2023
Location:
Qty of Cylinders: Cylinder Capacity:
Qty of Pilot Cylinders: Cylinder Capacity:
Carried Out Satisfactory
7. Checked operation of pressure switch(es)? Quantity: Yes No Yes No N/A
11. Checked other shutdowns? Specify: Yes No Yes No N/A
Set Time: Actual Time:
Electric Pneumatic
Room Temperature:
CYLINDERS (additional cylinders to be listed on following supplement, if applicable):
Serial # Manufacturer
Empty
Required
Agent
Actual
Temperature
°C/°F PSI/BAR Last Hydro
Date Next
Hydro Due
Technician: Date:
Manufacturer:
Space Protected:
19. Checked labeling of system components?
20. Is system sealed and inspection tag attached?
21. Is system armed and ready for use?
9. Checked damper operation?
13. Checked operation of alarms?
15. Checked operation of visual indication?
16. Checked operation of stop valves?
14. Type of Alarms
10. Checked fuel oil pump shutdown?
12. Time Delay
COMMENTS: ANY REMARKS plus EXPLAIN ANY NO Answers
I state that the information on this form is correct at the time and place of the inspection, and that all equipment tested at this time was left in operational condition upon completion of this inspection except as noted in Comments section above.
17. Checked operation of remote stations?
18. Checked operation of heat actuation?
3. Condition of cylinders (Satisfactory/Unsatisfactory)?
4. Checked for manufacturer recalls?
5. Checked lever/pressure actuation?
6. Checked condition of flex hoses?
8. Checked ventalation shutdown?
GENERAL REQUIREMENTS
1. Disconnect releasing mechanisms?
2. Contents in cylinders checked by weight/ liquid level?
Information on this form covers the minimum requirements of the current edition of 46CFR, appropriate classification requirements, as well as the latest version of the OEM manual (unless otherwise directed by the authority having jurisdiction).
SYSTEM INFORMATION
INSPECTION OF FIXED SUPPRESSION SYSTEM
Dates of Service
Comments
MFSS.46CFR.XX.01.001
US Army Corps of Engineers Kidde CO2 Room Pump room
4 50 2 50
N/A ✔ ✔ 30 30
0 ✔ ✔ 2 ✔ ✔
84116 kidde 98 148 50 148 7/18 7/30 26060 kidde 118 168 50 168 7/18 7/30 3064293 kidde 114 164 50 164 7/18 7/30 69310 kidde 100 150 50 150 7/18 7/30
System was tested with a 35LB CO2 cylinder.
Andrew Johnson 4/4/2023
LOCATION AGENT SIZE MFG
MFG
DATE
UL
RATING
GROSS
WGT
BRACKET
TYPE
LAST
HYDRO
HYDRO
DUE
LAST
6YR
6 YR
DUE
PASS FAIL
Date:
I state that the information on this form is correct at the time and place of the inspection, and that all equipment tested at this time was left in operational condition upon completion of this inspection except as noted in Comments section above.
Technician:
R=Recharge 6=Six Year Maint. H=Hydrotest A=Annual Re-Certification C=Condemned
Dates of Service:
INSPECTION OF PORTABLE EXTINGUISHERS
Information on this form covers the minimum requirements of the current edition of NFPA10, 46CFR, as well as the latest version of the OEM manual (unless otherwise directed by the authority having jurisdiction).
COMMENT KEY
SERIAL COMMENTS
MEXT.10.2018.01.001
US Army Corps Of Engineers
491449 Bridge CO2 15 35 Veh 4/23 4/28 ✔
7768931 Bridge ABC 10 2022 Veh 2028 ✔
19006543 Galley ABC 10 2024 Veh 2030 ✔
108190 Galley CO2 15 35 Veh 3/24 3/29 ✔
19006531 Passage Way ABC 10 2024 Veh 2030 ✔
181077 Passage Way CO2 15 35 Veh 4/24 4/29 ✔
794057 Engine Room Port CO2 15 4/23 4/28 ✔
527868 Engine Room STBD CO2 15 4/23 4/28 ✔
181078 Engine Room FWD CO2 15 4/24 4/29 ✔
801871 Engine Log Room ABC 20 1/24 1/30 ✔
528397 Tool Room ABC 20 2019 2025 ✔
3020400 Tool Room CO2 15 4/23 4/28 ✔
502237 Pump Room CO2 15 4/23 4/28 ✔
3020474 Cylinder Room CO2 15 4/23 4/28 ✔
2515379 Port Doghouse CO2 15 4/23 4/28 ✔
R/C Tool Room ABC 10 2022 2028 ✔
759765 Pump Room CO2 15 4/23 5/28 ✔
549906 Pump Room CO2 15 4/23 4/28 ✔
987374 Cylinder room CO2 15 4/23 4/28 ✔
Joe Sheridan 4/17/2023