About this file

This solicitation is for construction and renovation services within building 3-3045 at Joint Special Operations Command (JSOC) compound at Fort Bragg, North Carolina. The Army Corps of Engineers, Wilmington District requires a contractor to provide all labor, materials, equipment, and supervision necessary to complete wall, floor and ceiling repairs; removal and replacement of non-load bearing walls; door reconfigurations; renovation of existing latrines; fire sprinkler system reconfiguration; communication work; replacement of HVAC systems serving both floors including ductwork; natural gas implementation; upgraded mechanical systems; and replacement of selective electrical and plumbing systems including fixtures. The project value is between $1 million to $5 million. This will be a 100% competitive small business set-aside awarded as a single firm fixed price contract. The North American Industry Classification System code is 236220 for commercial and institutional building construction. Offerors must register in the System for Award Management to be eligible for award.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DSS,ETBDDSS,ETBD

LTWR

LTWS

LTWR

LTWR

LTWS LTWR

LTWSLTWR

LTWS

EF-5, ETBD.

EF, ETBD.

SEE ENLARGED

PLAN D2/MD102

DLDL

DLDL

DL

DL

DLDL

DL

LTWR LTWR LTWR

EF-4, ETBD.

LTWS LTWS LTWS

AHU-2, ETR

UH-2, ETR

24x24 24x24

48x18

DD

FD, ETBD

EF-2, ETBD.

DSS,ETR

P-3 & P-4,ETBD

FD, ETBD

FD, ETBD

ET, ETBD

1" LTWS&R, ETBD

2-1/2" CWR, ETBD

SB SB

SB

SBSB

SB SB

DLDL

1. EXISTING CHILLED WATER PUMPS TO BE

DEMOLISHED INCLUDING ASSOCIATED TRIPLE

DUTY VALVE.

2. EXISTING CONTROL PANEL SHALL BE REPLACED.

CONTROLLERS SHALL BE REMOVED AND

REINSTALLED IN NEW NEMA 4 PANELS.

3. EXISTING ROOFTOP UNIT (RTU) SHALL BE

DEMOLISHED INCLUDING ASSOCIATED WIRE AND

CONDUIT BACK TO ORIGINATING SOURCE. CAP,

INSULATE, AND SECURE EXISTING ROOF CURB.

REFERENCE DETAIL E4 ON SHEET M-502 FOR

SECURITY BAR REQUIREMENTS FOR ROOF

PENETRATIONS.

KEY NOTES (THIS SHEET):X

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

R A

LE

IG

H , N

C

-3

(9

1-

(9

)8

-7

FA

X

LI

C E

N S

E

F -0

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

S O

LI

C

IT

A

TI

O

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

TI

O

N

A

M A

R K

S

IZ

E

S U

B M

IT

TE

D B

Y

D A

TE

C O

N

TR

A C

T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

TE

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

FO

R

T B

R A

G G

, N O

R

TH

C A

R O

LI

N

A R

E N

O V

A

TE

B U

IL

D

IN

G

-3

5, J S

O C

FY

, S C

-0

-1

READY TO ADVERTISE

A

U G

U S

T

W

2P M

R

W

2H N

D

FI

LE

N A

M E

A

N S

I D

U .S

. A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D

A R

LI

N

G

TO

N A

V E

W

IL

M

IN

G

TO

N , N

O R

TH

C

A R

O

LI

N A

W

IL

M

IN

G

TO

N D

IS

TR

IC

T

CHARLOTTE | 704.295.4263

705 EAST MOREHEAD STREET, 28202

NC License No: C-2848 AME Project No: 19087

M

D

2.

D

G N

MD102

W

LK

W

LK

FF

R

M E

C H

A N

IC

A

L

- S

E C

O N

D F

LO

O

R P

LA

N

D

E M

O

LI

TI

O

N

A1 MECHANICAL - SECOND FLOOR PLAN - DEMOLITION

SCALE: 1/8"=1'-0"

N

D2 MECHANICAL - ENLARGED MECHANICAL ROOM - DEMOLITION

SCALE: 1/4"=1'-0"

M

JM

Ad de d by A m en dm en t 3

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

VTC CONF

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

ELEC

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

VAULT

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text

AutoCAD SHX Text

SUPPLY

AutoCAD SHX Text

AutoCAD SHX Text

ELEC

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

MECH

AutoCAD SHX Text

AutoCAD SHX Text

TELE

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

TELE

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 217B

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 217A

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

AutoCAD SHX Text

BRIEFING

AutoCAD SHX Text 217C

AutoCAD SHX Text

ELEC

AutoCAD SHX Text

AutoCAD SHX Text

MECH

AutoCAD SHX Text

AutoCAD SHX Text

TELE

AutoCAD SHX Text

AutoCAD SHX Text X:\2019 Projects\19087 FB Design Renovation of Bldg 3-3045\Dwgs\Mechanical\19087 MD102

AutoCAD SHX Text

7/27/2020 8:28:35 AM

AutoCAD SHX Text Landon Kivett

AutoCAD SHX Text

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text 8'

AutoCAD SHX Text

GRAPHIC SCALE: 1/8"=1'-0"

K7ECPMAG

Typewritten Text

K7ECPMAG

Polygon

K7ECPMAG

Polygon

K7ECPMAG

Callout

RTU, ETBD.

K7ECPMAG

Text Box

File details come from the government source that posted it. Updated .