This solicitation and supporting asbestos report provide details for a renovation project at Building 3-3045 at Fort Bragg, North Carolina. The Army Corps of Engineers seeks a contractor to complete construction and renovation work including wall, floor and ceiling repairs, selective non-load bearing wall removal and replacement, door reconfigurations, latrine renovations, fire sprinkler and communication system work, HVAC system replacement including ductwork on both floors, natural gas implementation, upgraded mechanical and electrical/plumbing systems replacement. The contractor must have a NAICS code of 236220 and be registered in SAM. The project value is between $1,000,000 to $5,000,000 and will be awarded as a 100% small business set-aside firm fixed price contract.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(Photo Not Available Due to National Security)
Signature
Solomon Locklear, Carolina Environmental Design, LLC NC License # 12601
Asbestos Survey for Renovation of
Building 3-3045 Fort Bragg, North Carolina
Prepared by Solomon Locklear, Carolina Environmental Design, LLC for the
Directorate of Public Works, Ft .Bragg, North Carolina
Table of Contents
Asbestos Inspection Report………………………………………………………...1
List of Tables
Table 1 Asbestos Table
Table 2 Carolina Environmental Inc. Analytical Report…………………..…….7
Table 3 Asbestos Samples Chain of Custody Forms
Appendices
Appendix A. Certifications and Accreditations…………………. ......... ………13
Asbestos Inspection Report
Introduction
Scope of the Investigation
This report documents the asbestos inspection and survey of Building 3-3045 at Ft. Bragg, North Carolina conducted on 03/04/2013.
Background
Building 3-3045 is a two story structure that is used by JSOC and the building is used specifically for office space. Due to national security concerns, the asbestos inspector was not allowed in the office areas of Building 3-3045. Most of the samples collected were collected from the hallways, mechanical rooms, electrical closets, janitorial closets and latrines. The outside of the building is constructed out of concrete. The windows of the building are constructed out of aluminum, held in place with rubber/silicone caulking. The roof is constructed from the top down with concrete surfaced expandable polystyrene foam insulation over single ply membrane over several inches of foam insulation over a metal roof deck. The inside walls are constructed out of both CMU (block) and drywall/joint compound. The ceilings of the building have drywall/joint compound that is covered with white 2’x2’ drop ceiling. The flooring system is constructed out of concrete. White 12”x12” floor tile is present in the hallways and offices on the first floor and 12”x12” floor tile and ceramic tile is present on the 2 nd floor. Due to not being able to assess all of the offices, it was not able to be determined if floor tile was present in each and every office. There is a mechanical room present on the outside of the building as well as on each floor. The pipes and elbows running throughout the mechanical room and building are covered with yellow fiberglass material, covered with a white thermal insulation wrap.
Description of study
Investigation
Areas of Building 3-3045 were visually inspected for suspected asbestos containing materials (ACM) by North Carolina accredited inspectors. A copy of the inspector’s accreditation certificate is included in Appendix A. Bulk samples of all suspect ACM’s were collected. This report details ACM as identified at the time of inspection only. Please be advised that if the building in to undergo demolition or renovation, additional sampling maybe required for hidden materials that were not accessible of sampling when the initial asbestos inspection was done. A focused inspection was conducted for the presence of asbestos containing building materials (ACBM). Laboratory results indicated that ASBESTOS WAS NOT DETECTED.
These results pertain only to that portion of the building for which renovation (work) actions are proposed and is not applicable to the remaining spaces in the building.
Carolina Environmental Inc. analyzed the bulk samples. The laboratory is accredited by the
National Voluntary Laboratory Accredited Program (NVLAP Accreditation sponsored by the
National Institute of Standards and Technology (NIST)). A Copy of their accreditation certificate is included in Appendix A. The samples were analyzed by the accepted method of polarized light microscopy (PLM) using EPA’s “Method For the Determination of Asbestos In Bulk Building
Materials”, EPA/600/R-93/116. The laboratories’ analytical report is included in Appendix A.
In compliance with the AHERA regulations, material is considered an Asbestos Containing
Material (ACM) when it contains greater than one percent asbestos. Likewise, in this report, any material containing concentrations greater than one percent asbestos will be considered
“positive”. Occasionally, materials containing less than one percent asbestos, or not sampled, are assumed to be a “positive” asbestos containing material at the discretion of the inspectors. A narrative discussion of the AHERA ACM types (i.e., thermal systems insulation, miscellaneous and surfacing materials) found in Building No. 3-3045 is included in this report where relevant.
Bulk sample information, estimated quantities of individual asbestos containing materials, and material characterization of asbestos containing materials appears on Table 1. The approximate location where each bulk sample was obtained is shown on the building floor plans, Figure 1.
Conclusions
ASBESTOS-CONTAINING MATERIAL NOT DETECTED.
Thermal System Insulation
TSI is insulation material applied to pipes, fittings, tanks, ducts, or on other interior structural components to prevent heat loss or gain, or water condensation, or for other purposes.
There was not any asbestos containing TSI materials detected in Building 3-3045.
Miscellaneous Materials
Miscellaneous materials include building material on structural components, structural members or fixtures, such as floor and ceiling tiles, and do not include surfacing or TSI. There was not any asbestos containing miscellaneous material found in Building 3-3045 at the time of sampling.
Surfacing
Surfacing material is friable material that is sprayed on, troweled on, or otherwise applied to surfaces for decorative or other purposes. No surfacing material was found to contain asbestos located in Building 3-3045 at the time of sampling.
TABLE 1
ASBESTOS TABLE
FORT BRAGG, BUILDING 3-3045
Date of Inspection: March 4 th , 2013
Inspector: Solomon Locklear
Inspector Certification Number: NC Number 12601
MATERIAL CHARACTERISTICS ASSESSMENT
Type Description/Location % Asbestos
Yes/No/Presumed
Quantity/Type
(If ACM)
Friable /
Non-
Friable
Condition Disturbance
Potential
MISCELLANEOUS
White 12”x12” Floor Tile
With Glue None Detected
MISCELLANEOUS Drywall/Joint Compound None Detected
MISCELLANEOUS 2’x2’ White Drop Ceiling None Detected
TSI Pipe Insulation None Detected
Sq. Ft.-Square Foot, Ln. Ft.-Linear Foot, C. Ft.-cubic Foot
Materials Containing Asbestos are in Bold Print.
Table 2
Table 3 Chain of Custody