PN91252_RTA_PLANS_unlocked.pdf
PDF 23 MB Posted
- Attached to
- PN 91252 Pedestrian Bridge Federal contract opportunity
- Solicitation number
- W912PM19R0012
About this file
PN 91252 Plans unlocked
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912PM19R0012-0007_Conformed.pdf | ||
| W912PM19R0012-0007.pdf | ||
| W912PM19R0012_PN_91252_Pedestrian_Bridge_Amendment_0005_-_Conform.pdf | ||
| Geotechnical_Report.pdf | ||
| W912PM19R0012_PN_91252_Pedestrian_Bridge_Amendment_0005_-_Mod.pdf | ||
| stormwater_vault_as-builts_-_pn91252.pdf | ||
| Amend_0003_91252_pedestrian_bride_modification.pdf | ||
| Amend_0003_91252_pedestrian_bride_conform.pdf | ||
| CU101.pdf | ||
| Technical_Summary_of_Changes.pdf | ||
| W912PM19R00120002_Conformed.pdf | ||
| W912PM19R00120002.pdf | ||
| W912PM19R00120001.pdf | ||
| W912PM19R00120001_Conformed.pdf | ||
| PN91252_RTA_PLANS.pdf | ||
| PN91252_RTA_SPECS.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F
IL
E N
A M
E
D R
A W
IN
G C
O D
E
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
W
IL
M
IN
G T
O N
N O
R T
H C
A R
O L
IN
A
D
A R
L
IN
G T
O N A
V E
N U
E W
IL
M
IN
G T
O N D
IS
T R
IC
T U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
G-000
C O
V E
R S
H E
E T of Engineers
US Army Corps
Wilmington District
J .M
IT
C
H E
L L
J .M
IT
C
H E
L L
O F
R E
E M
A N
"x
S
IZ
E
J
M A
N N
IN
G
A d v
C o v e r.
d g n
W P
M
R
R F P N
O
CONTRACT NO.:
RFP NO.: W912PM19R0012
ISSUE DATE:
APRIL 2019
PEDESTRIAN BRIDGE
PN 91252
FORT BRAGG, NORTH CAROLINA
TBD
F O
R T B
R A
G G
N O
R T
H C
A R
O L
IN
A P
N
P E
D E
S T
R
IA
N B
R
ID
G E
A P
R
IL
PN91252, FY 2018
FORT BRAGG
PEDESTRIAN BRIDGE OVER REILLY ROAD
SOLICITATION NO.: W912PM-19-R-0012
CONTRACT NO.:
ISSUE DATE: 6 MAR 2019
W I L
M
G d w g
J A
M E
S
S
W A
N N
J A
M E
S
S
W A
N N
R O
B
D
O W
N S
M A
R K
C
A S
P A
R
G-001
C O
V E
R
S
H E
E T
LOCATION MAP
ROCKINGHAM
LAURINBURG
FAYETTEVILLE
FORT BRAGG
VICINITY MAP
ARCHITECTURAL ELECTRICALCIVIL STRUCTURAL
A
R
D
E
N
N
E
S
T
G
R
U
B
O
A
D
B
A
S
T O
G
N
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
M
A R
H
F O
B
A
G G
N
O R
R
O L I N
A
F B
P
D
E S
T R
I A
N
B
R I D
G
N
SHEET ID
F I L
E N
A M
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
Y
D
E
W
P M
W
P M
R
D E
I P
T I O
N
READY TO ADVERTISE
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
S:\1784\178451226
G-001
G-002
G-003
G-004
G-005
GC101
GENERAL
VF101
CD101
CG101
CG501
CU101
CU501
CU502
CIVIL
S-001
S-002
S-003
S-004
S-101
S-102
S-103
S-104
S-105
S-106
S-201
S-202
S-203
S-301
S-302
S-303
S-304
S-501
S-502
S-510
S-520
S-521
S-522
STRUCTURAL
A-001
AE101
AE102
AE103
AE201
AE301
AE501
AE502
AE503
ARCHITECTURAL
G-001.DGN
G-002.DGN
G-003.DGN
G-004.DGN
G-005.DGN
GC101.DGN
VF101.DGN
CD101.DGN
CG101.DGN
CG501.DGN
CU101.DGN
CU501.DGN
CU502.DGN
S-001.DGN
S-002.DGN
S-003.DGN
S-004.DGN
S-101.DGN
S-102.DGN
S-103.DGN
S-104.DGN
S-105.DGN
S-106.DGN
S-201.DGN
S-202.DGN
S-203.DGN
S-301.DGN
S-302.DGN
S-303.DGN
S-304.DGN
S-501.DGN
S-502.DGN
S-510.DGN
S-520.DGN
S-521.DGN
S-522.DGN
A-001.DGN
AE101.DGN
AE102.DGN
AE103.DGN
AE201.DGN
AE301.DGN
AE501.DGN
AE502.DGN
AE503.DEG
COVER SHEET
VICINITY MAP AND PROJECT LOCATION
GENERAL CONSTRUCTION NOTES
GENERAL CONSTRUCTION NOTES
LEGEND AND ABBREVIATIONS
MATERIAL LAY DOWN AND CONTRACTOR PARKING AREAS
GENERAL NOTES
DESIGN DATA & ISOMETRIC VIEW
SPECIAL INSPECTIONS
SPECIAL INSPECTIONS
OVERALL FOUNDATION PLAN
FOUNDATION PLAN A
FOUNDATION PLAN B
OVERALL FRAMING PLAN
FRAMING PLAN A
FRAMING PLAN B
NORTH ELEVATION
SOUTH ELEVATION
RAMP ELEVATION
SECTIONS
SECTIONS
SECTIONS
SECTIONS
FOUNDATION DETAILS
FOUNDATION DETAILS
CMU TYPICAL DETAILS
RAMP/LANDING DETAILS
TYPICAL FRAMING DETAILS
TYPICAL FRAMING DETAILS
ABBREVIATIONS, SYMBOLS LEGEND, MATERIAL LEGEND, KEY NOTE LIST
BRIDGE ARCHITECTURAL PLAN - OVERALL
ENLARGED BRIDGE PLANS
ENLARGED BRIDGE PLANS
BRIDGE ELEVATION & ENLARGED BRIDGE SECTIONS & DETAILS
BRIDGE SECTIONS
BRIDGE DETAILS
MISCELLANEOUS DETAILS AND DOOR SCHEDULE
GUARDRAIL AND HANDRAIL DETAILS
EXISTING CONDITIONS PLAN
DEMOLITION PLAN
SEDIMENT & EROSION CONTROL PLAN
SEDIMENT AND EROSION CONTROL DETAILS
LAYOUT AND UTILITY PLAN & PROFILE
SANITARY SEWER DETAILS
SANITARY SEWER DETAILS
TITLESHEET ID. FILENAME
E-001
E-101
ES101
ELECTRICAL
E-001.DGN
E-101.DGN
ES101.DGN
LEGENDS, ABBREVIATIONS AND SCHEDULE
BRIDGE LIGHTING PLAN
ELECTRICAL SITE PLAN
US Army Corps of Engineers
WILMINGTON DISTRICT
L-101
L-102
L-101.DGN
L-102.DGN
LANDSCAPE PLAN - OVERALL
LANDSCAPE DETAIL, NOTES AND PLANT LIST
LANDSCAPE
RFP DATE: 19 APRIL 2018
R
E
I L
L
A
D
O
R
T
H
Z
A
B
I
T
O
S
A
D
O
U
T
H
SUMMER
CONSULTANTS
I N C O R P O R A T E D
3-6-2019
G-002
V I C
I N
I T
Y
M
D
P R
O J E
C
A T
I O
N
B
U
T
N
D
L
O
N
G
S
T
R
E
G
R
U
B
A
M
E
R
I
C
E
E
W
A
Y
Y
A
D
K
G
R
U
B
L
O
N
G
S
T
R
E
B
U
T
N
H
O
N
E
Y
C
U
B
R
A
V
D
B
R
A
V
D
G
R
U
B
M
U
R
C
H
S
R
A
N
D
O
L
K
N
X
K
N
SIMMONS AIRFIELD
R
E
I L
L
A
M
O
C
H
I
C
K
A
D
M
I
L
I
T
A
S
E
R
V
A
T
I
U
N
D
A
R
Y
B
A
S
T
O
G
I
V
E c
D
A
D c
D
A
D
N
O
R
M
A
N
A
R
D
E
N
N
S
P
O
O
N
M A
IN
E
N T
R A
N C
E
A
R
M
I S
T
E
L
I
T
A
S
E
R
V
A
T
I
O
N
B
O
U
N
D
A
R
Y
POPE ARMY AIRFIELD
ACP #1
RANDOLPH GATE
B
R
A
V
D
J
A
C
K
S
O
N
ALL AMERICAN GATECONTROL
POV REGISTRATION, 5AM-9PM
M
C
K
E
L
L
A
DIRECTORATE OF PUBLIC WORKS
SOLID WASTE OFFICE BLDG.
BLDG 31338
CHICKEN RD ACP
KNOX GATE / TRUCK PLAZA
(COMMERCIAL VEHICLE
REGISTRATION, 5AM-9PM
W
O
M
A
M
Y
M
E
D
I C
N
T
E
R
DIRECTORATE OF PUBLIC WORKS
BUILDING NO. 31631
BUTNER GATE
ROAD CLOSED WITH GATES OR
BARRIERS
MAJOR ROADS
STREETS
RAILROADS
INSTALLATION BOUNDARIES
INTERSTATE ROUTE
U. S. ROUTE
STATE ROUTE
LAKES
ACCESS ROUTE
ACP
ACCESS CONTROL POINT
LEGEND:
FORT BRAGG CANTONMENT
NOT TO SCALE
LAMONT ROAD
BORROW PIT
W
O
O
D
R
U
F
F
B
U
K
S
A
P
P
SOLID WASTE
TRANSFER STATION
PROJECT LOCATION
P
R
A
C
O
L
L
I
W I L M
G d w g
J A
M E
S
S
W A
N N
J A
M E
S
S
W A
N N
R O
B
D
O W
N S
M A
S
P A
R
1. PROPOSED HAUL ROUTE TO BE
VERIFIED BY CONTRACTING OFFICER.
NOTE:
CONTRACTOR LAYDOWN AREA
CONTRACTOR PARKING
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
M
A R
F O
A
G G
N
O R
R
O L
I N
A
F B
D
E S
T R
I A
N
B
R I D
N
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M
W P
M R
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
READY TO ADVERTISE
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
D
A R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
S:\1784\178451226
K
E
D
E
N
B
U
(24 HOURS)
(24 HOURS)
(M-F 5AM-9PM
SAT-SUN 9AM-9PM
USACE WILMINGTON DISTRICT
OFFICE
PROPOSED
HAUL ROUTE
SEE NOTES 8
& 9.
FORT BRAGG LAMONT
RECYCLING FACILITY
SEE GC101 FOR
CONTRACTOR LAY
DOWN AND
PARKING AREAS
POST ACCESS CONTROL POINT (ACP) PLAN & SECURITY NOTES
1. VERIFY HOURS OF ALL GATES THROUGHOUT PROJECT. PROJECT HOURS SUBJECT TO CHANGE.
2. AS DIRECTED BY THE USACE PM, THE CHICKEN ROAD ACP MAY BE AVAILABLE TO CONTRACTORS.
INFO AND HOURS FOR ACP'S CAN BE FOUND AT
WWW.BRAGG.ARMY.MIL/INDEX.PHP/MY-FORT-BRAGG/ALL-SERVICES/GATE-INFORMATION.
3. ALL VEHICLES ARE SUBJECT TO SEARCH, REGARDLESS OF MEANS OF ENTRY; AUTOMATED
INSTALLATION ENTRY, TEMPORARY PASS, OR NEITHER. ALL CONTRACTOR'S COMMERCIAL OR
PRIVATELY OWNED VEHICLE'S REQUIRE REGISTRATION.
4. ALL COMMERCIAL VEHICLES MUST ACCESS THE TRUCK PLAZA ON KNOX STREET. THE
INSTALLATIONS DEFINITION FOR A COMMERCIAL VEHICLE IS: ANY VEHICLE AS LARGE AS OR
LARGER THAN AN ENCLOSED 15-PASSENGER VAN (NOT USED FOR PASSENGER
TRANSPORTATION) OR ANY COMPANY VEHICLE PULLING AN ENCLOSED TRAILER OF ANY SIZE, AND
ALL CIVILIAN FUEL TRUCKS. THIS INCLUDES U-HAUL TRUCKS, UPS/FEDEX DELIVERY VEHICLES, ETC. THE ONLY EXCEPTION TO THIS DEFINITION APPLIES TO ACTIVE DUTY MILITARY CAC CARD
HOLDERS ONLY IF THE VEHICLE CAN SAFELY NEGOTIATE THE LANE AT FORCE PROTECTION
CONDITION (FPCON) NORMAL OR A.
5. IT IS A CRIME UNDER 18 USC 795 TO PHOTOGRAPH DEFENSE INSTALLATIONS WITHOUT FIRST
OBTAINING THE PERMISSION OF THE COMMANDING OFFICER OF THE MILITARY INSTALLATION. IT IS
ALSO A CRIME UNDER 18 USC 797 TO REPRODUCE, PUBLISH, SELL, OR OR GIVE AWAY ANY
PHOTOGRAPH, PICTURE OR GRAPHIC REPRESENTATION OF A DEFENSE INSTALLATION WITHOUT
FIRST OBTAINING THE PERMISSION OF THE COMMANDING OFFICER OF THE MILITARY
INSTALLATION.
6. FORT BRAGG IS DESIGNATED AS A RESTRICTED AREA. RESTRICTED AREA POSTING RESTRICTS
PERSONS GAINING ACCESS TO MILITARY INSTALLATIONS FROM CONDUCTING IMAGERY
SURVEILLANCE, PHOTOGRAPHY AND VIDEO RECORDING WITHOUT THE INSTALLATION
COMMANDERS CONSENT.
7. THE INTRODUCTION OF WEAPONS, AMMUNITION, EXPLOSIVES OR OTHER PROHIBITED ITEMS AND
PHOTOGRAPHY ON FORT BRAGG IS PROHIBITED WITHOUT SPECIFIC AUTHORIZATION FROM THE
COMMANDER.
8. KNOX GATE COMMERCIAL TRAFFIC ONLY, UNREGISTERED VEHICLES AND MATERIAL
DELIVERABLES.
9. KNOX GATE IS TO BE USED FOR UNREGISTERED VEHICLES. IN ADDITION ALL MATERIAL
DELIVERIES MUST ENTER THROUGH THE KNOX TO BE INSPECTED.
G
R
U
B
H
O
N
E
Y
C
U
K
N
R
E
I L
R
E
I L
DETOUR ROUTE
R
E
I L
N
E
W
R
T
H
THIS AREA SEE
INSET ABOVE
INSET SEE
BELOW
PROPOSED
HAUL ROUTE
SEE NOTES 2.
N E
R A
L
C
O N
S T
R U
C T
I O
N
N
O T
E S
W I L M
G d w g
G-003
A. CONTRACTOR SHALL COMPLY WITH CURRENT NORTH CAROLINA DEPARTMENT OF
ENVIRONMENTAL QUALITY (DEQ) EROSION AND SEDIMENT CONTROL PLANNING AND
DESIGN MANUAL AND FORT BRAGG WATER MANAGEMENT BRANCH (WMB) STANDARDS FOR
EROSION CONTROL WORK, IF APPLICABLE.
B. ALL NCDOT STANDARDS REFERENCES WILL BE THE LATEST EDITION. CONTRACTOR MAY
REFER TO HTTPS://CONNECT.NCDOT.GOV, IF APPLICABLE.
C. CONTRACTOR SHALL COMPLY WITH CURRENT UFC, NC BUILDING CODE AND OTHER
APPLICABLE REQUIREMENTS AS INDICATED ON THESE CONTRACT DOCUMENTS.
8. DEMOLITION
A. A ROAD CLOSURE AND DETOUR SIGNAGE PLAN MUST BE PROVIDED FOR APPROVAL BY THE
INSTALLATION 30 DAYS FOLLOWING NOTICE TO PROCEED. ALL PLANS MUST BE DESIGNED
AND SIGN BY A PROFESSIONAL ENGINEER LICENSED IN NORTH CAROLINA.
B. 30 DAYS PRIOR TO ANY ROAD OR LANE CLOSURES A SEPARATE DETOUR AND SIGNAGE PLAN
MUST BE PROVIDED TO THE BASE FOR EXECUTION APPROVAL.
C. ALL CONSTRUCTION AFFECTING TRAFFIC SHALL COMPLY WITH THE FORT BRAGG TRAFFIC
CONTROL IDC, MUTCD, AND NCDOT STANDARD DRAWINGS AND SPECIFICATIONS - LATEST
EDITION. AN ALTERNATE EMERGENCY TRAFFIC CONTROL DETOUR MAY BE REQUIRED.
9. TRAFFIC CONTROL
A. UNLESS SPECIFICALLY NOTED TO BE REMOVED, ALL EXISTING BUILDING COMPONENTS
AND OTHER SITE ITEMS SHALL REMAIN INTACT AND BE PROTECTED AGAINST DAMAGE
DURING THE CONSTRUCTION PERIOD.
B. THE CONTRACTOR SHALL EXERCISE CAUTION DURING DEMOLITION OPERATIONS. THE
CONTRACTOR SHALL REPAIR AND RESTORE ALL EXISTING CONSTRUCTION TO REMAIN THAT
IS DAMAGED DURING DEMOLITION OPERATIONS. REPAIRS TO DAMAGED WORK AREAS SHALL
MATCH EXISTING ADJACENT FINISHED SURFACES OR THE CONTRACTOR SHALL REPLACE
DAMAGED CONSTRUCTION WITH NEW WORK.
C. NO KNOWN ASBESTOS EXISTS WITHIN THIS PROJECT AREA. IF CONTRACTOR SUSPECTS
ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE PRESENT HE SHALL NOTIFY THE
CONTRACTING OFFICER'S REPRESENTATION IMMEDIATELY.
D. ANY AND ALL ASPHALT THAT REQUIRES DEMOLITION SHALL BE MILLED AND REMOVED FROM
THE INSTALLATION.
7. STANDARDS
10. EXISTING UTILITY INTERRUPTIONS
A. EXISTING UTILITIES MAY BE INTERRUPTED FOR A MAXIMUM OF 12 HOURS AT A TIME.
CONTRACTOR IS REQUIRED TO CONTACT THE COR AND OBTAIN APPROVAL PRIOR TO
ANTICIPATED INTERRUPTION. SEE SPECIFICATIONS FOR PER-APPROVAL REQUIREMENTS.
B. ALL UTILITY INTERRUPTIONS AND DURATIONS SHALL BE INDICATED ON THE CONTRACTOR'S
SCHEDULE AND COORDINATED WITH THE COR.
C. FIRE ALARM INTERRUPTIONS SHALL BE SCHEDULED IN WRITING WITH THE COR A MINIMUM OF
14 DAYS IN ADVANCE.
D. CONTRACTOR TO LOCATE TELECOM DUCT BANK FOR ADJACENT PROPERTIES PRIOR TO
CONSTRUCTION.
E. TRAFFIC SYNCHRONIZATION CABLING IS LOCATED WITHIN THE PROJECT AREA. THE
CONTRACTOR SHALL LOCATE ALL CABLING BY HAND PRIOR TO START OF CONSTRUCTION.
THIS SERVICE SHALL BE VISIBLY MARKED THROUGHOUT THE PROJECT. ANY DAMAGE TO THE
LINE SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE WITHIN 24 HOURS OF IDENTIFIED
DAMAGE.
11. EXTERIOR UTILITY WORK
A. ANY EXTERIOR ELECTRICAL WORK PERFORMED BY THE CONTRACTOR SHALL BE COORDINATED
WITH SANDHILLS UTILITY SERVICE (SUS). CONTACT MR. DAVID KEITH AT (910) 496-2220.
B. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MODIFICATIONS, WHETHER VERTICAL
ORHORIZONTAL, REQUIRED FOR THE INSTALLATION OF UTILITIES DUE TO EXISTING
CONDITIONS WHICH MAY NOT HAVE BEEN EVIDENT DURING THE DESIGN PROCESS.
12. SECURITY PROCEDURES FOR ACCESS
A. CONTRACTOR SHALL FOLLOW FT. BRAGG SECURITY REQUIREMENTS AT ALL TIMES.
REFER TO SPECIFICATION SECTION 01 14 00 FOR ADDITIONAL INFORMATION.
B. CONTRACTOR SHALL FOLLOW FT. BRAGG SECURITY POLICIES ON SITE AT ALL TIMES.
IN GENERAL, THE CONTRACTOR WILL BE GIVEN FULL ACCESS TO THE PROJECT SITE AS
SHOWN ON THE PLANS, HOWEVER, PERIODS MAY BE ENCOUNTERED WHEN NO CONTRACTOR OR
SUBCONTRACTOR PERSONNEL WILL BE ALLOWED ON THE CONSTRUCTION SITE. WORK
STOPPAGES DUE TO THOSE EVENTS WILL BE HELD TO AN ABSOLUTE MINIMUM, AND THE
CONTRACTOR WILL BE GIVEN AS MUCH ADVANCED NOTICE AS POSSIBLE. NOTICE OF THE WORK
STOPPAGE AND RESUMPTION WILL BE RELAYED THROUGH THE COR WHO WILL COMMUNICATE
THIS INFORMATION TO CONTRACTOR. SUCH WORK STOPPAGE WILL NOT BE THE BASIS FOR A
CLAIM AGAINST THE GOVERNMENT. THE GOVERNMENT HAS THE RIGHT TO INSTRUCT THE
CONTRACTOR TO EVACUATE THE SITE WITHOUT PRIOR NOTIFICATION AT ANY TIME AND MAY
REFUSE ENTRY OF ANY OR ALL CONTRACTOR PERSONNEL.
C. THE CONTRACTOR'S PERSONNEL MUST WEAR IDENTIFICATION IN ACCORDANCE WITH
FT. BRAGG SECURITY POLICIES AT ALL TIMES.
D. ACCESS TO THE PROJECT AREA IS LIMITED TO NORMAL WORK HOURS (0730 TO 1600)
UNLESS SPECIFICALLY APPROVED BY THE COR FOR SPECIFIED PERIODS OF TIME OUTSIDE THE
NORMAL WORK HOURS. EXCLUDES FEDERAL HOLIDAYS.
1. INSTALLATION PERMITS:
· BOILERS & GENERATORS PERMIT - DPW-ECB AIR QUALITY - MIKE FISHER, REM - NA
· BORROW PIT PERMIT - DPW - ENVIRONMENTAL BRANCH (SUBMIT 14 CALENDAR DAYS
PRIOR TO WORK).
· CONSTRUCTION AND DEMOLITION (C&D) WASTE PERMIT FOR FORT BRAGG LAMONT ROAD
CONSTRUCTION AND DEMOLITION LANDFILL FACILITY - DPW - ENVIRONMENTAL BRANCH.
NOTE: LANDFILL HAS REACHED ITS CAPACITY TO ACCEPT CONSTRUCTION AND DEMOLITION WASTE
AND WILL NO LONGER ACCEPT CONSTRUCTION AND DEMOLITION WASTE (TO INCLUDE FRIABLE
ASBESTOS CONTAINING MATERIALS). CONTRACTORS NEED TO MAKE ARRANGEMENTS TO HAUL
CONSTRUCTION AND DEMOLITION WASTE OFF THE INSTALLATION TO A STATE CERTIFIED C&D
LANDFILL OR SUB TITLE "D" LANDFILL, UNTIL A NEW PHASE III SECTION OF THE LANDFILL IS OPEN AND
OPERATING. SEE DPW'S SOLID WASTE AND RECYCLING REQUIREMENTS, DATED 6 OCT 2016, OR
CONTACT JEFF SLOOP AT JEFFERY.W.SLOOP.CTR@MAIL.MIL OR FAX (910)396-4188, ATTN. SOLID
WASTE OFFICE.
· DIGGING/EXCAVATION PERMIT (FB FORM 1605-E) - DPW - FACILITIES ENGINEER
(SUBMIT 15 CALENDAR DAYS PRIOR TO WORK)
· LANDFILL DISPOSAL PERMIT-DPW-ENVIRONMENTAL SUSTAINMENT DIVISION (ESD), 910-396-3372.
· TITLE V AIR PERMITS (BASED ON TYPE OF MATERIAL DUST, BOILERS AND DOMESTIC WATER HEATERS)
- DPW - ENVIRONMENTAL BRANCH, ENVIRONMENTAL COMPLIANCE BRANCH (ECB)
· IRRIGATION - DPW WATER QUALITY PROGRAM MANAGER, SHANNON WESTON, 910-432-5093,
CHENEGA GLOBAL SERVICES, LLC, STORAGE TANKS AND WATER QUALITY PROGRAM,
FORT BRAGG-DPW-ECB SHANNON.R.WESTON.CIV@MAIL.MIL. - NA
13. PERMITS
2. FEDERAL
·NOTICE OF PROPOSED CONSTRUCTION OR ALTERATION - FAA FORM 7460-1
A. CONTRACTOR SHALL SECURE ALL PERMITS NECESSARY FOR CONSTRUCTION OF THE PROJECT.
DETERMINE FEE BASIS AND PAY ALL FILING FEES AT NO ADDITIONAL COST TO THE GOVERNMENT.
CONSTRUCTION SHALL NOT BEGIN ON ANY PHASE WITHOUT APPROPRIATE PERMITS.
B. PERMITS ARE TO BE MAINTAINED IN THE CONTRACTOR'S ONSITE CONSTRUCTION OFFICE, ORGANIZED
IN A 3 RING BINDER, TABBED AND WITH A TABLE OF CONTENTS FOR INSPECTION BY THE GOVERNMENT.
C. THE FOLLOWING PERMITS MAY BE REQUIRED FOR PROJECT AT FT. BRAGG.
7. THE PERMITS, AS LISTED ABOVE, ARE NOT INTENDED TO BE A COMPLETE LIST OF PERMITS.
CONTRACTOR IS TO ADD ANY ADDITIONAL PERMITS AS THEY BECOME KNOWN, AND IS TO BE MODIFIED
AND SUBMITTED TO THE GOVERNMENT FOR REVIEW AND APPROVAL.
·WELDING
·CUTTING
·HEATING
2. CONSTRUCTION PHASING & PROJECT SCHEDULES
A. CLOSURE OF REILLY ROAD SHALL BE LIMITED TO WEEKEND WORK ONLY WITH A MINIMUM OF
30 DAYS ADVANCED NOTICE.
B. DETOUR FOR THE REILLY ROAD SHALL FOLLOW THE ROUTE DICTATED ON SHEET G-002.
ALTERNATE ROUTE SUGGESTIONS MUST BE APPROVED BY THE CONTRACTING OFFICER
REPRESENTATIVE.
C. CONTRACTOR IS RESPONSIBLE FOR DOCUMENTING THE EXISTING CONDITION OF ADJACENT
STRUCTURES PRIOR TO ANY CONSTRUCTION ACTIVITIES. A FOLLOWING UP INSPECTION
SHALL BE COMPLETED THROUGHOUT CONSTRUCTION. THIS SHALL INCLUDE A DAILY
INSPECTION FOLLOWING PILE DRIVING ACTIVES. CONTRACTOR IS RESPONSIBLE FOR AND
DAMAGE TO ADJACENT STRUCTURES RESULTING FROM CONSTRUCTION ACTIVITY.
D. THE CONTRACTOR SHALL ENSURE THAT HIS ACTIVITIES SHALL NOT INTERFERE WITH THE
OPERATIONS CONDUCTED AT SURROUNDING BUILDINGS AND WORK AREAS.
E. CONTRACTOR SHALL NOT BLOCK ACCESS TO EXISTING BUILDINGS, ROADS AND/OR FACILITIES.
F. CONTRACTOR SHALL PROVIDE A CONSTRUCTION PHASING PLAN AND PROJECT SCHEDULE TO
THE COR PRIOR TO CONSTRUCTION AND MOBILIZATION. CONTRACTOR SHALL PROVIDE WEEKLY
UPDATES ON THE PROJECT SCHEDULE FOR FULL DURATION OF PROJECT. THE WEEKLY
UPDATES SHALL BE PROVIDED SHOWING THE SCHEDULE FOR THE UPCOMING 2 WEEKS
INCLUDE UPDATES REGARDING THE PHASING OF CONSTRUCTION.
G. ADJACENT AREAS WILL BE OCCUPIED BY GOVERNMENT PERSONNEL THROUGHOUT THE
CONSTRUCTION PERIOD. CONTRACTOR SHALL NOT ALLOW CONSTRUCTION ACTIVITIES TO
DISRUPT ON-GOING GOVERNMENT OPERATIONS DURING DEMOLITION AND CONSTRUCTION.
3. CONTRACTOR STAGING AREA
A. SEE EROSION CONTROL PLAN SHEET CG101.
NOTE THAT LAMONT ROAD BORROW PIT WILL NOT BE IN OPERATION FOR THE CONSTRUCTION
PHASE OF THIS PROJECT FOR OBTAINING FILL DIRT. ALL REQUIRED FILL MATERIAL MUST
COME FROM A LOCATION OFF THE FACILITY. DISPOSAL OF SOIL IS NOT ACCEPTED ON BASE.
A. CONTRACTOR SHALL INSTALL TEMPORARY FENCING AROUND THE GENERAL PROJECT SITE.
THE TYPE, MATERIAL, HEIGHT, AND LOCATION OF THE FENCE SHALL BE IN ACCORDANCE
WITH SPECIFICATIONS AND APPROVED BY THE GOVERNMENT PRIOR TO INSTALLATION.
B. ALL WORK ACTIVITIES AND STORAGE SHALL BE CONFINED WITHIN THE ESTABLISHED
PROJECT LIMITS UNLESS SPECIFICALLY AUTHORIZED BY THE COR FOR SPECIFIED PERIODS
OF TIME.
C. THE CONTRACTOR MUST HAVE AT LEAST ONE EMPLOYEE ONSITE TO RECEIVE AND DIRECT
PLACEMENT OF DELIVERED MATERIALS AND SUPPLIES.
1. CONSTRUCTION METHODS AND PROCEDURES & CONTRACTOR ACCESS
A. THE WORK FOR THIS PROJECT CONSISTS OF FURNISHING ALL LABOR, EQUIPMENT,
TRANSPORTATION, AND MATERIALS NECESSARY TO PERFORM ALL WORK IN STRICT
ACCORDANCE WITH THE PROJECT PLANS & SPECIFICATIONS, APPLICABLE DIRECTORATE OF
PUBLIC WORKS (DPW) DRAWINGS, UNIFIED FACILITIES CRITERIA FORT BRAGG INSTALLATION
DESIGN GUIDELINES (IDG) AND OTHER CONTRACT DOCUMENTS. THE SCOPE OF WORK OF THIS
CONTRACT IS REFERENCED IN PROJECT SPECIFICATIONS SECTION 01 00 05.
B. THE CONTRACTOR SHALL REFER TO THE PROJECT PLANS & SPECIFICATIONS IN ALL
SITUATIONS. THE CONTRACTOR SHALL BRING CONFLICTS BETWEEN PROJECT PLANS &
SPECIFICATIONS PRIOR TO BID TO THE ATTENTION OF THE CONTRACTING OFFICER
REPRESENTATIVE (COR) FOR RESOLUTION. ALL MATERIALS AND WORKMANSHIP SHALL
CONFORM TO THE PROJECT SPECIFICATIONS.
C. ALL DIMENSIONS AND CONDITIONS TIED TO OR OTHERWISE RELATED TO EXISTING
CONSTRUCTION ARE SUBJECT TO FIELD VERIFICATION BY THE CONTRACTOR. VERIFICATION
SHALL BE MADE PRIOR TO ORDERING, FABRICATING, OR CONSTRUCTING ANY RELATED
STRUCTURAL COMPONENTS. WHERE DISCREPANCIES OCCUR, THE CONTRACTOR SHALL ADVISE
THE COR IMMEDIATELY AND PROVIDE THE COR WITH THE CORRECT DIMENSIONS AND
CONDITIONS.
D. THE CONTRACTOR SHALL PROVIDE ONSITE SANITARY FACILITIES FOR HIS WORKERS DURING
THE ENTIRE CONSTRUCTION PHASE. COORDINATE LOCATION WITH COR.
E. THE CONTRACTOR SHALL ADEQUATELY PROTECT ALL EXISTING SITE FEATURES AND FACILITIES
DURING DEMOLITION AND CONSTRUCTION.
F. PRIOR TO ANY DEMOLITION OR NEW WORK COMMENCING THE ELECTRICAL CONTRACTOR
SHALL ARRANGE A MEETING WITH THE COR AND FT. BRAGG REPRESENTATIVE TO DISCUSS ALL
ELECTRICAL OUTAGE PROCEDURES FOR SHUTDOWN OF ANY ELECTRICAL PANELS. THE
ELECTRICAL CONTRACTOR MUST NOTIFY THE COR, IN WRITING, AT LEAST 7 DAYS PRIOR TO
ANY ELECTRICAL SHUTDOWN DURING DEMOLITION OR NEW CONSTRUCTION.
3. COUNTY
·WATER WELL - NA
4. NC STATE PERMITS:
·DEMOLITION - NA
· ASBESTOS REMOVAL FOR DEMOLITION/RENOVATION - NCPH, RALEIGH (10 WORKING DAYS PRIOR TO
REMOVAL) - NA
·EROSION & SEDIMENT CONTROL (E&SC) PERMIT - NC DEQ DEPT OF WATER QUALITY (DWQ) - NA
·GENERAL STORMWATER DISCHARGE - NA
·GEOTHERMAL (POSSIBLE COUNTY INVOLVEMENT) - NA
·SEPTIC SYSTEM (POSSIBLE COUNTY INVOLVEMENT) - NA
·STORMWATER MANAGEMENT - NA
5. ONUS PERMIT:
·WATER AND SANITARY SEWER - NA
6. COE SAFETY
·PERMIT REQUIRED CONFINED SPACE (PRCSS) - (SEE EM 385-1-1, DATED 2014, PARA 34.A.06 (PAGE 791)
·HOT WORK PERMIT - (SEE EM 385-1-1, DATED 15 SEP 08, PARA 06.C.01 (PAGE 93) AND PARA 10.C.01
(PAGE 207) FORT BRAGG FIRE DEPARTMENT. (SUBMIT 14 CALENDAR DAYS PRIOR TO WORK.)
4. LAMONT ROAD BORROW PIT
6. EROSION AND SEDIMENT CONTROL
GENERAL NOTES:
J A
M E
S
S
W A
N N
J A
M E
S
S
W A
N N
R O
B
D
O W
N S
M A
S
P A
R
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
M
A R
F O
A
G G
N
O R
R
O L
I N
A
F B
D
E S
T R
I A
N
B
R I D
N
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M
W P
M R
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
READY TO ADVERTISE
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
D
A R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
S:\1784\178451226
5. GENERAL NOTES
CONTRACTOR SHALL COMPLY WITH THE MOST RESENT VERSION OF THE “FAA BASED NOTICE OF
PROPOSED CONSTRUCTION OR ALTERATION - OFF AIRPORT EXAMPLE” FORM 7460
CONTRACTOR SHALL COMPLY WITH THE MOST RECENTLY PUBLISHED FT. BRAGG SOLID WASTE AND
RECYCLING REQUIREMENTS. CON TACT JEFF SLOOP AT JEFFERY.W.SLOOP.CTR@MAIL.MIL OR FAX TO
(910)396-4188, ATTN: SOLID WASTE OFFICE FOR ADDITIONAL INFORMATION.
CONTRACTOR SHALL COMPLY WITH THE DOCUMENT TITLED “1-PERMITS - SECURITY -PHOTO-ALARACT
087-2008 COMMERCIAL IMAGERY.
CONTRACTOR TO COORDINATE WITH PN79437 CONTRACTOR (SOF TRAINING COMMAND).
CONTRACTOR TO COORDINATE WITH CASSANDRA MACKLINE FOOD COURT MANAGER, MACKLINECAAAFES.COM
910-582-6124 & FAYE SIMMONS ARBY'S MANAGER SIMMONSFA@AAFES.CO 910-339-0366.
E. IT IS A CRIME UNDER 18 USC 795 TO PHOTOGRAPH DEFENSE INSTALLATIONS WITHOUT
FIRST OBTAINING THE PERMISSION OF THE COMMANDING OFFICER OF THE MILITARY
INSTALLATION. IT IS ALSO A CRIME UNDER 18 USC 797 TO REPRODUCE, PUBLISH, SELL, OR GIVE
AWAY ANY PHOTOGRAPH, PICTURE, OR GRAPHIC REPRESENTATION OF A DEFENSE INSTALLATION
WITHOUT FIRST OBTAINING THE PERMISSION OF THE COMMANDING OFFICER OF THE MILITARY
INSTALLATION.
N E
R A
L
C
O N
S T
R U
C T
I O
N
N
O T
E S
G-004
THE FORT BRAGG LAMONT CONSTRUCTION AND DEMOLITION (C&D)
LANDFILL IS CLOSED AND WILL NOT BE ACCEPTING ANY C&D WASTE
AND ASBESTOS WASTE.
ALL CONTRACTORS SHALL USE A STATE CERTIFIED C&D LANDFILL OR
SUB TITLE “D” LANDFILL OFF FORT BRAGG FOR THE DISPOSAL OF
C&D AND ASBESTOS WASTE.
THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN DATA OF ALL
WASTE DISPOSED AND MATERIALS RECYCLED OFF FORT BRAGG.
THE DEPARTMENT OF THE ARMY (DA) AND THE NORTH CAROLINA
DEPARTMENT OF ENVIRONMENTAL QUALITY (NC DEQ) REQUIRES
MONTHLY AND ANNUAL REPORTING OF ALL MATERIALS (WASTE AND
RECYCLABLES) MANAGED BY FORT BRAGG. THE FORT BRAGG
ENVIRONMENTAL COMPLIANCE BRANCH, SOLID WASTE/RECYCLING
OFFICE IS RESPONSIBLE FOR COMPILING DATA INTO MONTHLY
DIRECTORATE REPORTS TO BE CONSOLIDATED INTO REPORTS FOR
THE DA AND THE NC DEQ. A PROVIDED FORM FROM THE SOLID
WASTE/RECYCLING OFFICE OR A CONTRACTOR FORM SHALL BE
FILLED OUT WITH THE TYPE OF WASTE OR RECYCLED MATERIAL, THE
WEIGHT OF THE WASTE/MATERIAL (TONS OR POUNDS) AND THE
FACILITY THE WASTE OR RECYCLABLES WERE DELIVERED. THIS
INFORMATION IS REQUIRED TO BE SENT TO THE FORT BRAGG SOLID
WASTE/RECYCLING OFFICE BY THE SECOND FRIDAY OF EACH
MONTH. EMAIL TO JEFF SLOOP AT JEFFERY.W.SLOOP.CTR@MAIL.MIL
OR FAX TO (910)396-4188, ATTN: SOLID WASTE OFFICE.
THE LAMONT LANDFILL FACILITY WILL ACCEPT RECYCLABLES ITEMS.
1) CONCRETE, BRICK AND BLOCK
- SHALL BE TESTED AND FREE OF ASBESTOS AND LEAD BASED
PAINT TO BE RECYCLED
- SHALL BE NO LARGER THAN 2' BY 2' PIECES OR EQUIVALENT
- SHALL BE MINIMAL AMOUNT OF DIRT IN LOAD
- SHALL HAVE NO REBAR PROTRUDING OUT OF THE CONCRETE
2) TREES, LIMBS AND STUMPS
- SHALL BE CUT TO 6 FEET OR LESS IN LENGTH
- IF THE TREE HAS A LARGE DIAMETER (EXAMPLE 3 FT. DIA.) IT
SHALL BE CUT TO LENGTHS OF 3 FEET OR LESS
- SHALL BE MINIMAL AMOUNT OF DIRT IN LOAD OR IN STUMP
ROOTS
- WILL EXCEPT GROUND WOOD CHIPS
3) PALLETS
- SERVICEABLE AND NON-SERVICEABLE PALLETS
4) SCRAP STEEL
- NO ITEMS REQUIRING DEMILITARIZED ACCEPTED
- NO ITEMS WITH LIQUIDS IN THEM
5) SCRAP ALUMINUM
- NO ITEMS REQUIRING DEMILITARIZED ACCEPTED
- NO ITEMS WITH LIQUIDS IN THEM
6) CARDBOARD TO BE RECYCLED
- A 40 YARD DUMPSTER IS AVAILABLE FOR CARDBOARD
- ALSO CARDBOARD CAN BE TAKEN TO THE FORT BRAGG
RECYCLING CENTER AT BLDG 3-1240, BUTNER AND REILLY
ROAD
- SHALL BE CLEAN OF PLASTICS, STYROFOAM, WOOD, METAL,
TRASH, ETC.
A LANDFILL USAGE PERMIT, FOR CONTRACTORS, SHALL BE
OBTAINED FROM THE DIRECTORATE OF PUBLIC WORKS,
ENVIRONMENTAL COMPLIANCE BRANCH, SOLID WASTE/RECYCLING
PROGRAM AT BLDG 3-1137, (910) 432-6412.
STATE LAW AND FORT BRAGG REGULATIONS REQUIRES COVERING
OF LOADS OF WASTE OR RECYCLABLES TO PREVENT LITTER.
ALL WASTE OR RECYCLABLE MATERIAL LOADS ARE SUBJECT TO BE
INSPECTED OF THEIR CONTENTS WHILE BEING PRESENT ON FORT
BRAGG.
SOLID WASTE AND RECYCLING NOTES
APPLY FERTILIZER/LIME AT RATES AS DETERMINED BY LABORATORY SOIL
ANALYSIS OF SOILS AT THE JOB SITE. IN THE ABSENCE OF THE SOIL ANALYSIS,
APPLY SOIL AMENDMENTS AT THE RATES INDICATED IN STEPS 2 AND 3.
1. AREA WILL BE TILLED TO 4" DEPTH.
2. APPLY LIME AT 70 POUNDS PER 1000 SQUARE FEET, OR 1.5 TONS PER
ACRE.
3. APPLY 10-20-20 FERTILIZER AT A RATE OF 850 POUNDS PER ACRE OR 20
POUNDS PER 1000 SQUARE FEET. THE FERTILIZER SHOULD BE EITHER
SLOW TIME RELEASE OR APPLIED IN TWO APPLICATIONS, HALF AT TIME OF
PLANTING AND THE SECOND HALF AFTER PERMANENT SEED GERMINATES.
4. THE LIME AND FERTILIZER WILL BE WORKED INTO THE TOP 2 TO 4 INCHES
OF SOIL PRIOR TO SEEDING.
5. SEED MIX AND RATE:
FORT BRAGG SEEDING SPECIFICATION
SITE AREA
DESCRIPTION
1) GROUND STABILIZATION *
STABILIZATION
TIME FRAME
PERIMETER DIKES,
SWALES, DITCHES
AND SLOPES
7 DAYS
STABILIZATION TIME
FRAME EXCEPTIONS
NONE
HIGH QUALITY
WATER (HQW)
ZONES
7 DAYS NONE
SLOPES STEPPER
THAN 3:1
7 DAYS
IF SLOPES ARE 10' OR LESS IN
LENGTH AND ARE NOT STEEPER
THAN 2:1, 14 DAYS ARE
ALLOWED.
SLOPES 3:1 OR
FLATTER
14 DAYS
7-DAYS FOR SLOPES GREATER
THAN 50 FEET IN LENGTH
ALL OTHER AREAS
WITH SLOPES
FLATTER THAN 4:1
14 DAYS
NONE (EXCEPT FOR
PERIMETERS AND
HQW ZONES)
* "EXTENSIONS OF TIME MAY BE APPROVED BY THE PERMITTING AUTHORITY
BASED ON WEATHER OR OTHER SITE-SPECIFIC CONDITIONS THAT MAKE
COMPLIANCE IMPRACTICABLE." (SECTION II.B(2)(b))
MAINTENANCE DURING ESTABLISHMENT PERIOD
MAINTENANCE OF THE SEEDED AREAS SHALL INCLUDE PROTECTING
EMBANKMENTS AND DITCHES FROM SURFACE EROSION; MAINTAINING EROSION
CONTROL MATERIALS AND MULCH; PROTECTING INSTALLED AREAS FROM
TRAFFIC; MOWING; WATERING; AND POST-FERTILIZATION.
MOWING
A. TURF AREAS; TURF AREAS SHALL BE MOWED TO A MINIMUM 3-INCH
HEIGHT WHEN THE TURF IS A MAXIMUM 4 INCHES HIGH. CLIPPINGS
SHALL BE REMOVED WHEN THE AMOUNT CUT PREVENTS SUNLIGHT
FROM REACHING THE GROUND SURFACE.
B. EROSION CONTROL AREAS: EROSION CONTROL AREAS SHALL BE
MOWED TO A MINIMUM 4 INCH HEIGHT WHEN THE PLANTS ARE
MAXIMUM 8 INCHES HIGH. CLIPPINGS SHALL BE REMOVED WHEN THE
AMOUNT CUT PREVENTS SUNLIGHT FROM REACHING THE GROUND
SURFACE.
POST-FERTILIZATION
AFTER THE PERMANENT GRASS HAS BEEN ACCEPTED, AND BETWEEN
THE DATES OF APRIL 15 AND OCTORBER 15, APPLY 425 POUNDS OF
FERTILIZER PER ACRE.
REPAIR OF REINSTALL
UNSATISFACTORY STAND OF GRASS PLANTS AND MULCH SHALL BE
REPAIRED OR REINSTALLED, AND ERODED AREAS SHALL BE REPAIRED
UNTIL A SATISFACTORY STAND OF GRASS RESULTS.
(Rv. 9 JUNE 2017)
TEMPORARY SEEDING
"COOL SEASON": PLANTED BETWEEN 1 SEPTEMBER AND 28 FEBRUARY 120 POUNDS
PER ACRE WINTER WHEAT (TRITICUM SPELTA)
"WARM SEASON": PLANTED BETWEEN 1 MARCH AND 31 AUGUST 65 POUNDS PER
ACRE GERMAN (SETARIA ITALICA), BROWN TOP (SETARIA ITALICA), OR FOX TAIL
MILLET (BRACHIARIA RAMOSUM)
PERMANENT SEEDING "COOL SEASON": PLANTED BETWEEN 1 SEPTEMBER
AND 28 FEBRUARY 50 POUNDS PER ACRE KENTUCKY 31 TALL FESCUE
(FESTUCA ARUNDINACEA) 25 POUNDS PER ACRE COMMON BERMUDA
(CYNODON DACTYLON), HULLED 25 POUNDS PER ACRE COMMON BERMUDA
(CYNODON DACTYLON), UNHULLED
"WARM SEASON": PLANTED BETWEEN 1 MARCH AND 31 AUGUST 50 POUNDS
PER ACRE KENTUCKY 31 TALL FESCUE (FESTUCA ARUNDINACEA) 50 POUNDS
PER ACRE COMMON BERMUDA (CYNODON DACTYLON), HULLED
STRAW MULCH: APPLY 4,000 POUNDS PER ACRE; LEAVING NO BARE SPOT LARGER
THAN A QUARTER. STRAW MUST BE STABILIZED BY EITHER USE OF EMULSIFIED
ASPHALT OR BY CRIMPING THE STRAW INTO THE GROUND.
EMULSIFIED ASPHALT: EMULSIFIED ASPHALT SHALL BE APPLIED AT A RATE
HEAVY ENOUGH THAT THE ENTIRE AREA APPEARS BLACK IN COLOR; WITH
PARTICULAR ATTENTION PAID TO THE EDGES OF AREAS, CRESTS OF RIDGES,
AND BANKS TO PREVENT WIND DAMAGE.
CRIMPING: STRAW MAY BE CRIMPED WITH A MULCH ANCHORING TOOL OR A
WHEEL DISK WITH DULL BLADES SET NEARLY STRAIGHT MAY BE USED AS A
MULCH ANCHORING TOOL. CRIMPING IS NOT PERMITTED ON SLOPES
STEEPER THAN 3:1.
HYDROSEEDING: HYDROSEEDING SHALL ONLY BE ALLOWABLE ON SLOPES
STEEPER THAN 1 HORIZONTAL TO 1 VERTICAL. STEPS 1 THROUGH 4 MUST BE
COMPLETED PRIOR TO HYDROSEEDING. HYDROSEEDING SHOULD BE APPLIED IN
TOW APPLICATIONS. THE FIRST APPLICATION WILL CONSIST OF
OF THE MULCH
AND
OF THE SEED AND THE SECOND APPLICATION WILL CONSIST OF
OF THE
MULCH AND
OF THE SEED. THE MULCH WILL INCLUDE A TRACKIFIER AND WILL BE
APPLIED AT A RATE OF 2,000 POUNDS PER ACRE OR THE MANUFACTURER'S
RECOMMENDATION, WHICHEVER IS HIGHER.
6. EXEMPTIONS: SPECIAL USE AREAS, SUCH AS WETLANDS, RIPARIAN AREAS,
FLOODPLAINS, GENERAL OFFICER QUARTERS AND HISTORIC DISTRICT. CONTACT
THE FORT BRAGG WATER MANAGEMENT BRANCH (WMB) AT 910-396-2301/2823
WHEN SEEDING THESE AREAS.
7. UPON COMPLETION OF THE PROJECT, PRIOR TO LEAVING THE SITE, THE WATER
MANAGEMENT BRANCH SHALL BE NOTIFIED TO INSPECT THE PROJECT. POC MR.
JACK WILSON AT 910-396-2301/2823.
NOTE: G.S. 113A-57 NO LAND-DISTURBING ACTIVITY SUBJECT TO THIS ARTICLE
SHALL BE UNDERTAKEN EXCEPT IN ACCORDANCE WITH THE FOLLOWING
MANDATORY REQUIREMENTS:
(1) PERMANENT GROUNDCOVER FOR ALL DISTURBED AREAS SHALL BE PROVIDED
WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER)
FOLLOWING THE COMPLETION OF CONSTRUCTION OR DEVELOPMENT (FINAL
GRADE).
(2) THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE
ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR OTHER ADEQUATE
EROSION-CONTROL DEVICES OR STRUCTURES. IN ANY EVENT, SLOPES LEFT
EXPOSED WILL, WITHIN 14 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF
GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY OR
PERMANENT GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO
RESTRAIN EROSION.
ALL PERIMETER DIKES, DITCHES, SWALES, PERIMETER SLOPES OR SLOPES
STEEPER THAN 3 HORIZONTAL TO 1 VERTICAL (3:1) SHALL BE PROVIDED
TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS
PRACTICABLE BUT IN ANY EVENT WITHIN 7 CALENDAR DAYS.
FORT BRAGG SEEDING SPECIFICATION (CONT.)
W I L M
G d w g
D A
N
S
A L T
S M
A N
D A
N
S
A L T
S M
A N
R O
B
D
O W
N S
M A
S
P A
R
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
M
A R
F O
A
G G
N
O R
R
O L
I N
A
F B
D
E S
T R
I A
N
B
R I D
N
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M
W P
M R
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
READY TO ADVERTISE
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
D
A R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
S:\1784\178451226
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
M
A R
F O
A
G G
N
O R
R
O L
I N
A
F B
D
E S
T R
I A
N
B
R I D
N
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M
W P
M R
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
READY TO ADVERTISE
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
D
A R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
S:\1784\178451226
DRAWING ABBREVIATIONS MATERIAL LEGEND
A ---------------------
A/E ARCHITECT/ENGINEER
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL
SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING
TILE
ADA AMERICANS WITH
DISABILITIES ACT
ADMIN ADMINISTRATION
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALUM ALUMINUM
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASSY ASSEMBLY
ATC ACOUSTICAL TILE
CEILING
AVG AVERAGE
B ---------------------
BD BOARD
BDRY BOUNDARY
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
CAV CAVITY
CBB CEMENTITIOUS (BACKER)
BOARD
CD CONSTRUCTION
DOCUMENTS
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED
/CONTRACTOR INSTALLED CFE
CONTRACTOR FURNISHED
EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE CFMF
COLD-FORMED METAL
FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTR CENTER
CU FT CUBIC FEET
D ---------------------
D DEPTH
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DRI DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
EA EACH
EIFS EXTERIOR INSULATION
AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF EL FINISH FLOOR ELEVATION
FGL FIBERGLASS
FIN FINISH
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLG FLOORING
FLR FLOOR
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT
TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GA GAGE/GUAGE
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER
REINFORCED GYPSUM
GLZ GLAZING
GMS GALVANIZED METAL STUD
GUT GUTTER
GYP BD GYPSUM BOARD
H --------------------
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING
CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBS POUND
LIB LIBRARY
LIN LINEAR
LOC LOCATION
LT LIGHT
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MFR MANUFACTURER
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY
MTG MOUNTING
MTL METAL
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OWSJ OPEN WEB STEEL JOIST
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER
AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFERENCE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RM ROOM
RO ROUGH OPENING
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SGL SINGLE
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SL SLOPE
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
STD STANDARD
STL JST STEEL JOIST
STOR STORAGE
STRB/HRN STROBE/HORN
T --------------------
T TREAD
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
THK THICKNESS
TN TRUE NORTH
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
ACCESSORY BY MARK
AFF
Elevation
A202
SIM
NORTH ARROW
SQUARE FOOTAGE
ROOM NUMBER
ROOM NAME
VIEW NUMBER
WALL TAG
WINDOW TAG
DOOR TAG
LEVEL
MARK
SHEET NUMBER
SIMILAR TAG
DETAIL LOCATED ON SHEET (MAY ALSO BE
REF. UNDER TITLE FOR MULTIPLE SHEETS)
SIMILAR TAG
ELEVATION RELATIVE TO
FINISHED FLOOR
BUILDING SECTION
99 SIM
A103
99 SIM
AE101
VIEW NUMBER
SHEET NUMBER
SIMILAR TAG
PLAN NORTH INDICATOR
TRUE NORTH
MATCHLINE 11/ AE-101.A1MATCH LINE
NUMBER ON
MATCHING SHEET
CONTINUATION SHEET
DETAIL LOCATED
ON SHEET
AE101
A
VIEW IDENTIFIER
ROOM TAG WITH SQUARE FOOTAGES*
DETAIL CALLOUT
CALLOUT - DETAILS
ELEVATION
MATCH LINE
SIM
SIMILAR TAG
SIM
B
A202
SIM
A202
______________VIEW NUMBER
SHEET NUMBER
SIMILAR TAG
WALL SECTION
99 SIM
AE101
VIEW NUMBER
SHEET NUMBER
SIMILAR TAG
DETAIL CALLOUT
GRID HEAD
VIEW NUMBER
SHEET NUMBER
SIMILAR TAG
BUILDING ELEVATION
VIEW NUMBER
EXTENT OF DETAIL
KEYED NOTE
REVISION NOTE
C
D
EARTH - COMPACTED
FILL
CONCRETE
BRICK - MASONRY
STEEL
PLYWOOD
RIGID INSULATION
BATT INSULATIONFINISHED WOOD
BLOCKING
CONTINUOUS WOOD
CONCRETE MASONRY
UNIT (PLAN)
CONCRETE MASONRY
UNIT (SECTION) GLASS MAT
SHEATHING
SPRAY-FOAM
INSULATION
SAND, FIREPROOFING,
MORTAR, GROUT,
PLASTER, DRYWALL
SYMBOLS LEGEND
A202
SIM
103A
A
1A
W1
ROOM NAME
100 SF
GB
CEILING TAG C1
PLAN
NORTH
T
R
U
E
N
O
R
T
H
FIRE EXTINGUISHER
CABINET
G-005
L E
G E
N D
B
R E
V I A
T I O
N S
D A
N
S
A L
T S
M A
N
D A
N
S
A L
T S
M A
N
R O
B
D
O W
N S
M A
S
P A
R
W I L
M
G d w g
SIM
O
I
E
STOP BAR
H
C
H
C
H
C
H
C
H
C
H
C
H
C
H
C
POND
U N
F I N
I S
H E
D
P
A V
I N
G
C O
T
A I N
I N
G
W
A L
L
C O
T
A I N
I N
G
W
A L
L
C O
N C
RESTAURANT
DRIVE-THRU
EQUIPMENT
ON CONC PAD
ASPHALT
ASPHALT
G
R
A
V
E
L
A S
P H
A L T
ASPHALT
ASPHALT
DUMPSTER
ENCLOSURE
C O
N C
W
A L
K D
R I V
E
PROPOSED PEDESTRIAN BRIDGE
R E
I L
A
D
O
R
T H
B O
U N
D
A R
B Y
I V
E
T
H R
U
B U
R G
I V
E
T
R H
U
ARDENNES STREET
K
E
D
E
N
B
U
R
E
E
T
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
M
A R
F O
A
G G
N
O R
R
O L
I N
A
F B
D
E S
T R
I A
N
B
R I D
N
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M
W P
M R
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
READY TO ADVERTISE
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
D
A R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
S:\1784\178451226
GC101
CONTRACTOR SITE AREAS
1"=50'
W I L M
G
C d w g
J A
M E
S
S
W A
N N
J A
M E
S
S
W A
N N
R O
B
D
O W
N S
M A
S
P A
R
GC101
M A
T E
R I A
L
L A
Y
D
O W
N
A N
D
C
O N
T R
A C
T O
R
P A
R K
I N
G
A
R E
A S
1. CONTRACTOR IS RESPONSIBLE FOR REPAIR AND/OR
REPLACE ANY DAMAGE CAUSED TO THE EXISTING
PROPERTY. THIS INCLUDES BUT IS NOT LIMITED TO
PARKING LOT, PARKING LOT SIGNAGE, IRON RAIL FENCE,
DUMPSTER ENCLOSURE, ROAD SURFACES AND SIDEWALKS.
2. THE FOLLOWING AREAS WITHIN THE LAY DOWN AREAS SHOWN
SHALL NOT BE IMPACTED BY THE CONSTRUCTION OF THIS
PROJECT: DUMPSTER ACCESS, EMERGENCY VEHICLE ACCESS,
ADA PARKING SPACES & DELIVERY TRUCK ACCESS TO
BUILDING D-2104.
3. TWO WEEKS PRIOR TO PROJECT START SUBMIT PEDESTRIAN
AND VEHICULAR CIRCULATION PLAN TO COR FOR APPROVAL.
NOTE:
BLDG #2402
BLDG #2104
BLDG #H4802
P R
O P
O S
N
T R
A C
T O
R
L A
Y
D
O W
N
A
R E
A
P
R
O
P
O
S
N
T
R
A
C
T
O
R
L
A
Y
D
O
E
A
P R
O P
O S
N
T R
A C
T O
R
P A
R K
I N
G
A
R E
A
CONTRACTOR MAY TEMPORARILY POSITION ITEMS
(CRANES ETC.) IN THIS LOCATION ON AN EVENT BY
EVENT BASIS WITH A MAXIMUM LIMIT OF ONE WEEK
DURATION AND TWO WEEKS ADVANCE NOTICE.
BLOCKING OF THE PARKING LOT EXIT IS NOT
ALLOWED AT ANY TIME.
PEDESTRIAN BRIDGE
LIMITS OF
CONSTRUCTION
PEDESTRIAN BRIDGE
LIMITS OF
CONSTRUCTION
JFK PLAZA
W x
W x
W x
S
S x
W x
S
S x
S
S x
S
S x
S S x
S S x
S S x
S S x
W x
W x
W x
W x
W x
W x
W x
W
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
WV
W x
W x
BUILDING D-2402
C
S
S x
S
S x
S
S x
S D x
S D x
S D x
S D x
S D x
S D x
SD
x
SD
x
SD
x
SD
x
SD
x
SD
x
SD
x
SD
x
S
S x
S
S x
S
S x
S
S x
S
S x
S
S
CB
GUT=279.06'
INV=274.1' 24" HDPE SW
INV=274.1' 30" HDPE E
CB
GUT=280.74'
INV=275.2' 24" HDPE S
INV=274.9' 24" HDPE NE
CB
GUT=284.55'
INV=276.7' 24" HDPE SW
INV=276.6' 24" HDPE N
CB
GUT=281.33'
INV=277.2' 24" HDPE S
INV=277.2' 24" HDPE NE
CB (N)
GUT=279.17'
INV=274.4' 18" HDPE S
INV=274.3' 18" HDPE N
CB (S)
GUT=279.20'
INV=274.4' 18" HDPE N
SS
x
SS
x
SS
x
SS
x
S S x
S S
S S x
S S x
S S x
S S x
S S x
S S x
S S x
DI
TOP=288.08'
INV=283.2' 24" HDPE S
INV=283.1' 24" HDPE N
DI
TOP=290.90'
INV=285.0' 18" HDPE S
INV=285.0' 24" HDPE N
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
S S x
S S x
S
S x
A
B
A
N
D
S D x
S D x
S D x
S D x
H
C
H
C
H
C
H
C
H
C
S D x
SD
x
SD
x
SD
x
SD
x
SD
x
SD
x
SD
x
S D x
S D x
S D x
S
D x
S D x
S D x
S D x
S D x
S D
S
D x
S
D x
S
D x
S D x
S
D x
S
D x
CB
GUT=276.38'
INV=273.2' 18" HDPE S
INV=272.7' 24" HDPE N
C O
T
A I N
I N
G
W
A L
L
C O
T
A I N
I N
G
W
A L
L
TOP=289.55'
INV=286.0' 4" PVC S
INV=275.1' 8" PVC E
INV=275.1' 8" PVC N
C O
N C
RESTAURANT
DRIVE-THRU
EQUIPMENT
ON CONC PAD
1-STORY
BRICK
BUSINESS
ASPHALT
ASPHALT
ASPHALT
SD
x
S
D x
S
D x
DI
TOP=287.3'
INV=284.0' 12" RCP S
INV=279.4' 18" RCP N
INV=279.0' 24" RCP W
INV=279.2' 24" RCP E
TOP=283.78'
INV=277.6' 12" UNK E
INV=274.6' 18" RCP S
INV=274.6' 24" RCP N
CB
GUT=284.0'
INV=278.8' 12" UNK
RIPRAP
S D x
S D x
S D x
S D x
A
P
P
R
O
X
S
T
O
R
M
V
A
U
L
T
TOP=280.40'
INV=274.8' 36" CMP S
INV=271.8' 36" CMP N
TOP=282.07'
INV=272.5' 8" MTL S
INV=271.9' 8" MTL NE
TOP=282.80'
INV=272.3' 8" PVC W
INV=272.2' 8" MTL N
TOP=289.93'
TOP DROP=283.3' 8" PVC S
INV=273.9' BOT DROP 8" PVC S
INV=273.1' 8" PVC N
INV=273.1' 8" PVC E
CB
GUT=277.3'
INV=274.4' 12" PVC
C O
N N
E C
S
O U
N D
S D x
SD
x
5 1
DUMPSTER
ENCLOSURE
C O
N C
W
A L
K D
R I V
E
R E
I L
A
D
A R
B Y
I V
E T
H R
U
AAFES BLDG H-4802
C x
C x
C x C x
C x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
C x
C x
C x
C x
C x
C x
C x
C x
C x
C x
G x
G x
G x
G x
G x
G x
E x
E
E
E
E
E
E
E E
E
E
E O
I
E O
I
U N
K
C x
C x
E x E x
C x
C x
W x
W x
W x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
W x
W x
W x
W x
W x
W x
W x
W x
W x
C x
LIMITS OF CONSTRUCTION
LIMITS OF CONSTRUCTION
L
I
M
I
N
S
T
R
U
C
T
I
O
N
L
I
M
I
N
S
T
R
U
C
T
I
O
N
LIMITS OF
CONSTRUCTION
W I L M
V
F d w g
J A
M E
S
S
W A
N N
J A
M E
S
S
W A
N N
R O
B
D
O W
N S
M A
S
P A
R
VF101
E X
I S
T I N
G
C
O N
D I T
I O
N S
P L
A N
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
M
A R
F O
A
G G
N
O R
R
O L
I N
A
F B
D
E S
T R
I A
N
B
R I D
N
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M
W P
M R
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
READY TO ADVERTISE
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
D
A R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
S:\1784\178451226
SS
H
E
T
EOI
CB
D
E
SD
H/C
S
G
UNK
E
LEGEND:
SURVEY CONTROL POINT
SIGN
TRAFFIC LIGHT SUPPORT POLE
PEDESTRIAN SIGNAL POLE
END OF INFORMATION
HANDICAP RAMP
LIGHT POLE
ELECTRIC HANDHOLE/PEDESTAL
ELECTRIC BOX
CABLE TELEVISION HANDHOLE, PEDESTAL
ELECTRIC METER
TELEPHONE/COMM MANHOLE
FIRE HYDRANT
WATER VALVE
SANITARY SEWER MANHOLE
SANITARY SEWER LINE
STORM DRAIN CATCH BASIN/CURB INLET
STORM DRAIN MANHOLE
STORM DRAIN LINE
UNDERGROUND ELECTRIC
UNDERGROUND COMM/TELEPHONE LINE
UNDERGROUND GAS LINE
UNKNOWN UNDERGROUND LINE
PINE TREE
FENCE
FDC
NOTES:
1. THE PURPOSE OF THIS MAP IS TO SHOW
TOPOGRAPHIC FEATURES AND INFORMATION
ONLY AND IS NOT TO BE USED FOR BOUNDARY OR
PROPERTY OWNERSHIP INFORMATION.
2. PROJECT NORTH IS NC GRID (NAD '83 NSRS 2011)
BASED ON GPS. ELEVATIONS ARE NAVD '88.
3. THIS MAP DOES NOT VERIFY THE EXISTENCE OF,
NOR CERTIFY THE LOCATION OF ANY
JURISDICTIONAL WETLANDS THAT MAY EXIST ON
OR NEAR THE PROPERTY.
4. UNDERGROUND UTILITIES WERE DESIGNATED
AND SURVEYED PER SUE LEVEL “B”
REQUIREMENTS PER INDUSTRY STANDARDS.
UTILITIES THAT WERE NOT CONDUCIVE ARE
SHOWN PER RECORD.
5. WE CANNOT GUARANTEE THAT ALL EXISTING
UNDERGROUND UTILITIES ACTIVE OR ABANDONED
IN THIS AREAS WERE LOCATED.
SCALE: 1" = 20'
0 20 40
X
X
X
X
X
C
X
VF101 1"=20'
EXISTING
CONDITIONS PLAN
SDMH
TOP=282.74'
INV=276.1' 36" RCP S
INV=275.9' 36" CMP N
SDMH
TOP=280.31'
INV=273.5' 24" RCP N
INV=273.8' 24" RCP S
OUT HIGHER THAN IN
SDMH
TOP=283.21'
INV=277.3' 30" RCP S
INV=276.8' 36" RCP W
INV=276.6' 36" RCP N
SDMH
TOP=282.61'
INV=276.8' 24" RCP NE
INV=276.8' 24" RCP S
INV=276.8' 24" RCP SW
SDMH
TOP=282.97'
SDMH
TOP=282.93'
INV=273.8' 24" RCP NE
INV=277.4' 30" RCP N
INV=273.7' 36" CMP W
SDMH
TOP=283.04'
SDMH
TOP=283.79'
SDMH
TOP=283.67'
INV=274.6' 36" RCP S
INV=273.6' 36" CMP N
CB
GUT=283.1'
INV=274.8' 24" RCP S
INV=274.5' 36" RCP N
DI
TOP=282.1'
INV=275.1' 24" RCP W
INV=275.1' 24" RCP N
SDMH
TOP=285.08'
INV=273.9' 36" CMP
SDMH
TOP=289.32'
INV=285.29' 8" PVC W
INV=278.71' 30" RCP N
INV=278.02' 36" CMP E
ELECTRIC PANELS
ELEC. BOX
TRANSFORMER
CONCRETE
CONCRETE
WATER AND MUD
COVERS CONC.
B L
BRICK PAVERS
x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
WV
W x
W x
BUILDING D-2402
B U
I L
D I N
G
D
C
E O
I
S
S x
S
S x
S
S x
S
S x
S
S x
S
S x
S
S x
S
S x
S
S x
SS
x
SS
x
SS
x
S S x
S S x
S S x
S S x
S S x
S S x
S S x
S S x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
S S x
S S x
S
S x
H
C
H
C
H
C
H
C
H
C
H
C
U N
F I N
I S
H E
D
P
A V
I N
G
C O
T
A I N
I N
G
W
A L
L
C O
T
A I N
I N
G
W
A L
L
C O
N C
RESTAURANT
DRIVE-THRU
EQUIPMENT
ON CONC PAD
ASPHALT
ASPHALT
DUMPSTER
ENCLOSURE
C O
N C
W
A L
K D
R I V
E
BLDG H-4802
R E
I L
A
D
A R
B Y
I V
E
T
H R
U
BUILDING
ENTRANCE
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
M
A R
F O
A
G G
N
O R
R
O L
I N
A
F B
D
E S
T R
I A
N
B
R I D
N
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M
W P
M R
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
READY TO ADVERTISE
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
D
A R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
S:\1784\178451226
CD101
DEMOLITION PLAN
1"=20'
W I L M
C
D d w g
J A
M E
S
S
W A
N N
M A
L E
Y
R O
B
D
O W
N S
M A
S
P A
R
CD101
D E
M O
L I T
I O
N
P
L A
N
SANITARY SEWER & WATER LINES SHOWN ALONG WITH
DEMOLITION ASSOCIATED WITH THEM, ARE INCLUDED
AS BID OPTION 1.
REMOVE EXISTING CONCRETE WALK. DEMOLITION WILL BE
TAKEN TO THE APPROPRIATE CONSTRUCTION JOINT. ANY
DAMAGE WILL REQUIRE THE REPLACEMENT OF THE
CONCRETE SQUARE. PATCHING IS NOT APPROPRIATE.
NO OPEN EXCAVATION FOR ELECTRICAL CONNECTION
REMOVE EXISTING SEWER MANHOLE
FLOWABLE FILL TO BE ADDED TO SANITARY SEWER
LINES ABANDONED IN PLACE
DEMOLISH EXISTING STORM AND OTHER FEATURES AS
NEEDED FOR NEW CONSTRUCTION. THESE EXISTING STORM
AND OTHER FEATURES SHALL BE RESTORED TO THEIR
ORIGINAL CONDITION ONCE CONSTRUCTION IS COMPLETE.
PROVIDE SAWCUT AT EDGE OF ASPHALT REMOVAL TO
PROVIDE A CLEAN EDGE.
KEY NOTES:
LEGEND:
DEMOLISH (SEE NOTE)
DEMOLISH PAVING CURB AND OTHER SURFACE FEATURES
FH AND LIGHT POLE TO REMAIN.
ABANDON IN PLACE
DEMOLISH
LIMITS OF CONSTRUCTION
REMOVE TREE
S E
E
E
L E
C T
R I C
E
E T
E S
F
N
T I N
U A
T I O
N
W x
W x
SS
x
SS
x
S
S x
S
S x
S
S x
S S x
S S x
S S x
S S x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
WV
W x
W x
BUILDING D-2402
B U
I L
D I N
G
D
C
0+001+002+003+004+005+00
B P
E P
0+501+50
2+50
3+504+50
W
S
S x
S
S x
S
S x
S D x
S D x
S D x
S D x
S D x
S D x
SD
x
SD
x
SD
x
SD
x
SD
x
SD
x
SD
x
SD
x
S
S x
S
S x
S
S x
S
S x
GUT=279.06'
INV=274.1' 24" HDPE SW
INV=274.1' 30" HDPE E
CB
GUT=280.74'
INV=275.2' 24" HDPE S
INV=274.9' 24" HDPE NE
CB
GUT=284.55'
INV=276.7' 24" HDPE SW
INV=276.6' 24" HDPE N
CB
GUT=281.33'
INV=277.2' 24" HDPE S
INV=277.2' 24" HDPE NE
CB (N)
GUT=279.17'
INV=274.4' 18" HDPE S
INV=274.3' 18" HDPE N
CB (S)
GUT=279.20'
INV=274.4' 18" HDPE N
SS
x
SS
x
S S x
S S x
S S x
S S x
DI
TOP=288.08'
INV=283.2' 24" HDPE S
INV=283.1' 24" HDPE N
DI
TOP=290.90'
INV=285.0' 18" HDPE S
INV=285.0' 24" HDPE N
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
S S x
S S x
S
S x
A
B
A
N
D
S D x
S D x
S D x
S D x
H
C
H
C
H
C
H
C
H
C
S D x
SD
x
SD
x
SD
x
SD
x
SD
x
SD
x
SD
x
S D x
S D x
S D x
S
D x
S D x
S D x
S D x
S D
S
D x
S
D x
S
D x
S D x
CB
GUT=276.38'
INV=273.2' 18" HDPE S
INV=272.7' 24" HDPE N
C O
T
A I N
I N
G
W
A L
L
C O
T
A I N
I N
G
W
A L
L
C O
N C
RESTAURANT
DRIVE-THRU
EQUIPMENT
ON CONC PAD
ASPHALT
ASPHALT
SD
x
S
D x
S D x
DI
TOP=287.3'
INV=284.0' 12" RCP S
INV=279.4' 18" RCP N
INV=279.0' 24" RCP W
INV=279.2' 24" RCP E
TOP=283.78'
INV=277.6' 12" UNK E
INV=274.6' 18" RCP S
INV=274.6' 24" RCP N
CB
GUT=284.0'
INV=278.8' 12" UNK
RIPRAP
S D x
S D x
S D x
S D x
A
P
P
R
O
X S
T
O
R
M
V
A
U
L
T
INV=271.8' 36" CMP N
TOP=282.07'
INV=272.5' 8" MTL S
INV=271.9' 8" MTL NE
TOP=282.80'
INV=272.3' 8" PVC W
INV=272.2' 8" MTL N
TOP=289.93'
TOP DROP=283.3' 8" PVC S
INV=273.9' BOT DROP 8" PVC S
INV=273.1' 8" PVC N
INV=273.1' 8" PVC E
CB
GUT=277.3'
INV=274.4' 12" PVC
C O
N N
E C
S
O U
N D
S D x
SD
x
S
D
DUMPSTER
ENCLOSURE
C O
N C
W
A L
K D
R I V
E
SS
x
S S x
C x
C x
C x C x
C x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
C x
C x
C x
C x
C x
C x
C x
C x
C x
C x
G x
G x
G x
G x
G x
E x
E
E
E
E
E
E
E E
E
E
E O
I
E O
I
U N
K
C x
C x
E x E x
C x
C x
W x
W x
W x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
W x
W x
W x
W x
W x x
W x
W x
W x
C x
S
F
S F
S F
S F
S F
S F
S F
S F
S F
S F
S F
S F
SFSF
S F
S F
S F
S F
S F
R E
I L
A
D
BLDG H-4208
BLDG ENTRANCE
A R
B Y
I V
E T
H R
U
S
F S
F S
F S
F
S
F
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
M
A R
F O
A
G G
N
O R
R
O L
I N
A
F B
D
E S
T R
I A
N
B
R I D
N
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M
W P
M R
D E
P
T I O
N
READY TO ADVERTISE
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
D
A R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
S:\1784\178451226
C-101
CONTROL PLAN
SEDIMENT & EROSION
1"=20'
W I L M
C
G d w g
J A
M E
S
S
W A
N N
J A
M E
S
S
W A
N N
R O
B
D
O W
N S
M A
S
P A
R
CG101
S E
D I M
E N
T
A
N D
E R
O S
I O
N
C
O N
T R
O L
P L
A N
IP
IP
IP
IP
IP
LEGEND:
INLET PROTECTION - SEE DETAIL 2 SHEET CG501
SEDIMENT FENCE - SEE DETAIL 1 SHEET CG501
LIMITS OF DISTURBANCE
SF
IP
SCALE: 1" = 20'
0 20 40
NOTES:
1. PLACE CLEARANCE WARNING SIGN IN ACCORDANCE WITH MUTCD REQUIREMENTS. USE MUTCD
SIGN TYPE W12-2 DISPLAYING " 17' - 9" ".
2. CONTRACTOR TO PROVIDE ADDITIONAL SEDIMENT AND EROSION CONTROL MEASURES, AS
NEEDED, TO KEEP ARBY'S DRIVE THRU CLEAR OF SEDIMENT
3. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADDITIONAL EROSION CONTROL MEASURES AS
REQUIRED TO RETAIN SILT ON SITE UNTIL FINAL ESTABLISHMENT.
4. CONTRACTOR TO CLEAN EXISTING STORM INLETS AFFECTED BY PROJECT AT COMPLETION OF
PROJECT.
LIMIT OF DISTURBANCE
LIMIT OF DISTURBANCE
LIMIT OF DISTURBANCE
LIMIT OF DISTURBANCE
LIMIT OF
DISTURBANCE
LIMIT OF
DISTURBANCE
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
M
A R
F O
A
G G
N
O R
R
O L
I N
A
F B
D
E S
T R
I A
N
B
R I D
N
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M
W P
M R
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
READY TO ADVERTISE
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
D
A R
L I N
G T
E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
S:\1784\178451226
J A
M E
S
S
W A
N N
J A
M E
S
S
W A
N N
R O
B
D
O W
N S
M A
S
P A
R
CG501
S E
D I M
E N
T
A
N D
E R
O S
I O
N
C
O N
T R
O L
D E
T A
I L S
FOR CURB INLETS WITHOUT GRATES
FOR CURB INLETS WITH GRATES
MAINTENANCE
1. REMOVE SEDIMENT FROM BEHIND DEVICE ONCE DEPTH
HAS REACHED HALF FULL.
2. CLEAN THE DEVICE AS NECESSARY WITH HIGH PRESSURE
WASH OR BROOM.
GUTTER EEL, GUTTER BUDDY OR
APPROVED EQUAL COMPRESSED
TIGHTLY AGAINST CURB
PROVIDE 2' RUNOUT
AGAINST CURB
EXISTING CURB & GUTTER
POSITION OVERFLOW FEATURE
AT CENTER OF OPENING
PROVIDE 2' RUNOUT
AGAINST CURB
EXISTING CURB INLET
F
L
O
W
F
L
O
W
F
L
O
W
EXISTING PAVEMENT
FLOW
F L
O W
FLOW
GUTTER EEL, GUTTER BUDDY OR
APPROVED EQUAL COMPRESSED
TIGHTLY AGAINST CURB &
ANCHOR TO GRATE W/ PLASTIC
OR WIRE TIES
EXISTING PAVEMENT
EXISTING CURB INLET
EXISTING CURB & GUTTER
CG101
NTS
CURB INLET PROTECTION
CG501
FILL SLOPE
GROUND LINE
4" MIN.
8" MIN
COMPACTED FILL (8" MIN.)
6' W/HIGH
STRENGTH
FABRIC WITHOUT
WIRE FENCE
S T
E E
L
P O
S T
ANCHOR FILTER
FABRIC MIN. 8" DEEP
AND KEY IT IN 4"
HORIZONTALLY
N
M
I N
5' LONG MIN. STEEL POST
FILTER FABRIC
1. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT OF POLYOLEFINS OR
POLYESTER, WHICH IS CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS
CONFORMING TO THE REQUIREMENTS IN ASTM D 6461. SYNTHETIC FILTER FENCE
SHOULD CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS TO PROVIDE A
MINIMUM OF 6 MONTHS OF EXPECTED USABLE CONSTRUCTION LIFE AT A
TEMPERATURE RANGE OF 0 TO 120 DEG F.
2. STEEL POSTS SHALL BE 5'-0" MIN. IN HEIGHT, 1.33 LB/LINEAR FT STEEL AND SHALL HAVE
PROJECTIONS…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.