CU101.pdf
PDF 1 MB Posted
- Attached to
- PN 91252 Pedestrian Bridge Federal contract opportunity
- Solicitation number
- W912PM19R0012
About this file
Revised Sheet
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912PM19R0012-0007.pdf | ||
| W912PM19R0012-0007_Conformed.pdf | ||
| W912PM19R0012_PN_91252_Pedestrian_Bridge_Amendment_0005_-_Conform.pdf | ||
| W912PM19R0012_PN_91252_Pedestrian_Bridge_Amendment_0005_-_Mod.pdf | ||
| Geotechnical_Report.pdf | ||
| stormwater_vault_as-builts_-_pn91252.pdf | ||
| Technical_Summary_of_Changes.pdf | ||
| Amend_0003_91252_pedestrian_bride_conform.pdf | ||
| Amend_0003_91252_pedestrian_bride_modification.pdf | ||
| W912PM19R00120002_Conformed.pdf | ||
| W912PM19R00120002.pdf | ||
| W912PM19R00120001.pdf | ||
| W912PM19R00120001_Conformed.pdf | ||
| PN91252_RTA_SPECS.pdf | ||
| PN91252_RTA_PLANS_unlocked.pdf | ||
| PN91252_RTA_PLANS.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W x
W x
W x
SS
x
S
S x
S
S x
S S x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
W x
WV
W x
W x
BUILDING D-2402
B U
I L D
I N
G
D
C
S
S x
S
S x
S
S x
S
S
CB
GUT=284.55'
INV=276.7' 24" HDPE SW
INV=276.6' 24" HDPE N
CB
GUT=281.33'
INV=277.2' 24" HDPE S
INV=277.2' 24" HDPE NE
CB (N)
GUT=279.17'
INV=274.4' 18" HDPE S
INV=274.3' 18" HDPE N
CB (S)
GUT=279.20'
INV=274.4' 18" HDPE N
SS
x
SS
x
S S x
DI
TOP=288.08'
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
S S x
S S x
S
S x
A
B
A
N
D
H
C
H
C
C O
N C
R
E T
A I N
I N
G
W
A L
L
ASPHALT
A
P
P
R
O
X S
T
O
R
M
V
A
U
L
T
TOP=282.80'
INV=272.3' 8" PVC W
INV=272.2' 8" MTL N
TOP=289.93'
TOP DROP=283.3' 8" PVC S
INV=273.9' BOT DROP 8" PVC S
INV=273.1' 8" PVC N
INV=273.1' 8" PVC E
GUT=277.3'
INV=274.4' 12" PVC
C O
N N
E C
T S
B
Y
S
O U
N D
X
X X X X X X
X
S
D
X
X X X X X X
X
DUMPSTER
ENCLOSURE
C O
N C
W
A L K
D
R I V
E
SS
x
S S x
C x C x
E x
E x
E x
C x
C x
C x
C x
G x
G x
E O
I
U N
K
C x
C x
E x E x
C x
C x
W x
W x
W x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
W x
W x
W x
W x
W x
C x
BLDG H-4802
R E
I L L
O A
D
O N
E W
A
R
T H
4+64 - 4+84 EMERGENCY
ACCESS DRIVE/WALK
G x
G x
G x
PROPOSED PEDESTRIAN BRIDGE
0+001+002+003+004+005+00
B P
E P
0+501+50
2+50
3+504+50
L1
A
B
C
S
S
S
S
D
W
H.B. N 500,310.6 , 2,001,202.4
H.B.
CONNECT TO
EXIST WATER
N 500,283.6
E 2,001,208.2
6" WATER PROVIDE STEEL CASING UNDER BRIDGE
W
A T
E R
A R
B Y
D
I V
E
T H
R O
U G
H
5'
E L E
V A
T I O
N
E L E
V A
T I O
N
STATION
PEDESTRIAN BRIDGE ALIGNMENT
HORZ. SCALE 1"=20'
VERT. SCALE 1"=20'
0+001+002+003+004+005+005+20
REILLY ROAD
DRIVE
THRU
SERVICE DRIVE
LIMITS OF FIELD SURVEY
S T
A
E D
G
M E
R G
E N
C
E S
S
D
R I V
E W
A L K
S T
A
E D
E
R G
E N
C
E S
S
D
R I V
E W
A L K
S T
A
P R
O P
O S
E D
S E
R V
I C
E
C
U R
B
S T
A
P R
O P
O S
E D
S E
R V
I C
E
C
U R
B
S T
A
W A
T E
R
S T
A
W A
T E
R
S T
A
C U
R B
S T
A
C U
R B
S T
A
C O
M M
S T
A
T E
L E
S T
A
T E
L E
S T
A
G A
S
S T
A
E L E
C
S T
A
C U
R B
S T
A
C U
R B
S T
A
C U
R B
E X
I S
T
S
D
S T
A
I N
V
E
L
E X
I S
T
S
D
S T
A
I N
V
E
L
E X
I S
T
S
S
S T
A
I N
V
E
L
S T
A
E X
I S
T I N
G
W
A T
E R
S T
A
E L E
C T
R I C
A L
S T
A
C
O M
S T
A
C
O M
S T
A
E L E
C T
R I C
A L
S T
A
W A
T E
R
S T
A
S W
M
C
P
I
S T
A
S W
M
C
C E
N T
E R
L I N
E
F
U
T M
E N
T
S T
A
C E
N T
E R
L I N
E
U
T M
E N
T
S T
A
C E
N T
E R
L I N
E
U
T M
E N
T
S T
A
C E
N T
E R
L I N
E
U
T M
E N
T
S T
A
C E
N T
E R
L I N
E
U
T M
E N
T
S T
A
10.3' BOTTOM OF GIRDER TO EXISTING GROUND
17.6'
10.6'
SIDEWALK
2' MIN.
S T
A
W
T
E R
W
S
T E
E L
C
A S
I N
G
SANITARY SEWER STRUCTURE TABLE
STRUCTURE #
D
A
B
C
STRUCTURE TYPE
6" CLEANOUT
SEE DETAILS SHEET
CU501 & 502
SEE DETAILS SHEET
CU501 & 502
6" CLEANOUT
NORTHING
500360.33
500466.04
500415.53
500374.88
EASTING
2001583.96
2001560.62
2001609.29
2001617.73
SANITARY SEWER PIPE TABLE
STRUC. - STRUC.
C - D
A - B
B - C
INSIDE DIA. (in.)
4" @ 2.16%
8" @ 3.32%
4" @ 1.54%
Length (ft)
36.8
70.1
41.5
MATERIAL
SCHED.40 PVC
SCHED.40 PVC
SCHED.40 PVC
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
M
A R
H
F O
A
G G
N
O R
R
O L
I N
A
F B
D
E S
T R
I A
N
B
R I D
N
SHEET ID
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
US Army Corps of Engineers
C A
T E
G O
D
E
W P
M
W P
M R
D E
P
T I O
N
J O
N E
S
F
R A
N K
L
S
U I T
E
R A
L E
I G
H
N
C
F
A X
L I C
E N
READY TO ADVERTISE
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
W I L M
I N
G T
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
D
A R
L I N
G T
V E
W I L M
I N
G T
O N
N
O R
R
O L I N
A
CU101
PLAN & PROFILE
LAYOUT AND UTILITY
1"=20'
W I L M
C
U d w g
J A
M E
S
S
W A
N N
J A
M E
S
S
W A
N N
R O
B
D
O W
N S
M A
K
S
P A
R
CU101
L A
Y O
U
U
I L
I T
Y
P L
O
F I L
E
PEDESTRIAN BRIDGE ALIGNMENT
LINE #
L1
LENGTH
500.00
DIRECTION
S78°03'22"W
START STATION
0+00.00
START COORD(NORTH,EAST)
500390.655 , 2001630.774
END STATION
5+00.00
END COORD(NORTH,EAST)
500287.178 , 2001141.599
MH "A" EXISTING
INV. OUT = 273.89
8" INV. IN = 273.99
TOP = MATCH EXISTING
GRADE 287.0 ±
MH "B"
8" INV. OUT = 276.32
4" INV. IN = 284.46*
TOP = MATCH EXISTING
GRADE 289.5±
MH "C"
4" INV. OUT = 285.10*
4" INV. IN = 285.20*
TOP = MATCH EXISTING
GRADE 291.1 ±
NOTES:
1. PLACE MH'S A & B OVER EXISTING 8" SANITARY SEWER.
2. NOTIFY COR IF EXISTING 8" SANITARY SEWER ELEVATIONS VARY FROM DESIGN
ELEVATIONS.
3. PROVIDE STANDARD 4" CLEANOUT AT STRUCTURE "D".
4. VERIFY EXISTING 4" IN INVERT ELEVATION AT NEW STRUCTURE "D".
5. RUN NEW 4" PVC TO STRUCTURE "C" THEN TO STRUCTURE "B" AT MINIMUM
-2% GRADE.
6. PERMANENT SET BOLLARD. SEE ARCHITECTURAL SHEET AE102 FOR LOCATION.
SEE PERMANENT BOLLARD DETAIL SHEET CU502.
7. REMOVABLE BOLLARD. SEE ARCHITECTURAL SHEET AE102 FOR LOCATION.
SEE REMOVABLE BOLLARD DETAIL SHEET CU502.
8. RELOCATE EXISTING FH ASSEMBLY. SEE NOTE 9.
9. NEW LOCATION RELOCATED FH ASSEMBLY. ℄ FH N 500,327.3 , E 2,001,176.8
10. PROVIDE STEEL CASING FOR EXISTING WATER LINE UNDER RAMP.
11. PROVIDE MINIMUM 3 FT. COVER FOR NEW WATER LINE.
12. MAINTAIN EMERGENCY EGRESS AT ALL TIMES.
SANITARY SEWER & WATER LINES SHOWN AND ALL DEMOLITION
ASSOCIATED WITH THEM, IS INCLUDED AS BID OPTION 1. IN
ADDITION ALL ASPHALT, BRICK PAVEMENT, CURB AND GUTTER
REMOVED OR DAMAGED AS PART OF THIS INSTALLATION SHALL
BE REPLACED IN KIND AT THE CONTRACTORS EXPENSE.
NOTE:
BUILDING D-2402
RELOCATE ELECTRICAL
5 FEET EAST AWAY FROM
PIER FOOTING
SCALE: 1" = 20'
0 20 40
LIMIT OF CONSTRUCTION
LIMIT OF CONSTRUCTION
LIMIT OF
CONSTRUCTION
LIMIT OF CONSTRUCTION
L I M
C
O N
S T
R U
C T
I O
N
LIMIT OF CONSTRUCTION
N E
W
C
O N
C R
E T
E
W
A L
K
6'
* ELEV. MAY VARY SEE
NOTES THIS SHEET.
NEW CONDUIT FOR PEDESTRIAN
BRIDGE LIGHTING. CONNECT TO
EX. TRANSFORMER. SEE ELEC.
DWGS FOR DETAILS
A
B
C
SANITARY SEWER KEY NOTES:
SEE NOTE 6.
SEE NOTE 6.
SEE NOTE 7.
SEE NOTE 8.
SEE NOTE 9.
SEE NOTE 10.
SEE NOTE 12
CONC.
WALK
mcaspar Text Box mcaspar Snapshot mcaspar Text Box Revised by Amendment 0003
File details come from the government source that posted it.