188/401
C-01
C-02
C-03
T-01
SHEET NO. TITLE FILE NAMEFILE NO.
GENERAL
LEGEND SYMBOLS AND ABBREVIATIONS
VERTICAL AND HORIZONTAL CONTROL DATUM
T-02
T-03
T-04
T-05
SHEET NO. TITLE FILE NAMEFILE NO.
SHEET NO. TITLE FILE NAMEFILE NO.
SHEET NO. TITLE FILE NAMEFILE NO.
CIVIL
GEOTECHNICAL
STRUCTURAL
INDEX TO CONTRACT DRAWINGS
INDEX TO CONTRACT DRAWINGS
CROSS-SECTIONS STA 346+20 TO STA 356+00
CROSS-SECTIONS STA 358+00 TO STA 370+00
PROJECT NOTEST-06
PROJECT HORIZONTAL CONTROL POINTS
TYPICAL SECTIONS
188/431S-01
TITLE FILE NAMEFILE NO.
GENERAL STRUCTURAL NOTES
G-01
G-02
G-03
G-04
G-05
G-06
G-07
G-08
G-09
G-10
G-11
G-12
G-13
G-14
G-15
G-16
G-17
G-18
G-19
G-20
LOG OF BORING DYB11-1 PAGE 1 AND 2 OF 3
LOG OF BORING DYB11-2 PAGE 1 AND 2 OF 3
LOG OF BORING DYB11-2 PAGE 3 OF 3
LOG OF BORING DYB11-3 PAGE 1 AND 2 OF 3
LOG OF BORING DYB11-3 PAGE 3 OF 3
LOG OF BORING DYB11-4 PAGE 1 AND 2 OF 3
LOG OF BORING DYB11-4 PAGE 3 OF 3
LOG OF BORING DYB11-5 PAGE 1 AND 2 OF 3
LOG OF BORING DYB11-5 PAGE 3 OF 3
SOIL CEMENT - PLAN AND PROFILE STA 356+20.00 TO STA 364+00.00
SOIL CEMENT - PLAN AND PROFILE STA 364+00.00 TO STA 373+00.00
SOIL CEMENT - PLAN AND PROFILE STA 373+00.00 TO STA 380+00.00
C-04
C-05
C-06
C-07
COMBI-WALL - PLAN AND PROFILE STA 351+00 TO STA 356+40
COMBI-WALL - PLAN AND PROFILE STA 346+20 TO STA 351+00
C-08
C-09
C-10
C-11
C-12
C-13
C-14
C-15
S-02 SHEET PILE WALL DETAILS
SHEET NO. TITLE FILE NAMEFILE NO.
MISCELLANEOUS
ACCESS POINTS AND STAGING AREA/BATCH PLANT LOCATIONS
PROJECT LOCATION AND VICINITY MAPS
CROSS-SECTIONS STA 372+00TO STA 382+60
188/441M-01
BORING LOCATIONS AND GEOLOGIC MAP STA. 346+20 TO 351+00
BORING LOCATIONS AND GEOLOGIC MAP STA. 351+00 TO 357+00
BORING LOCATIONS AND GEOLOGIC MAP STA. 356+00 TO STA. 364+00
BORING LOCATIONS AND GEOLOGIC MAP STA. 364+00 TO STA. 373+00
BORING LOCATIONS AND GEOLOGIC MAP STA. 376+00 TO STA. 383+80
GEOLOGIC CROSS-SECTIONS STA. 355+00, STA. 358+00 AND STA. 380+00
LOG OF BORING DYB11-1 PAGE 3 OF 3 AND DYB11-1A
LOG OF BORING DYB09-01
LOG OF BORING DYB09-02
LOG OF BORING DYB09-03
SOIL CLASSIFICATION SYSTEM-ASTM D2487 FOR BORINGS
DYB11-01 THROUGH DYB11-05 AND DYB09-01 THROUGH DYB09-03
188/402
188/403
188/404
188/405
188/406
188/411
188/412
188/413
188/414
188/415
188/416
188/417
188/418
188/419
188/420
188/421
188/422
188/423
188/424
188/432
188/451
188/452
188/453
188/454
188/455
188/456
188/457
188/458
188/459
188/460
188/461
188/462
188/463
188/464
188/465
188/466
188/467
188/468
188/469
SMLBCS001NX.DGN
SMLBCS302DT.DGN
SMLBCG001VM.DGN
SMLBCB601PP.DGN
SMLBCB602PP.DGN
SMLBCB603PP.DGN
SMLBCB604PP.DGN
SMLBCB605PP.DGN
SMLBCB606XS.DGN
SMLBCB607BH.DGN
SMLBCB608BH.DGN
SMLBCB609BH.DGN
SMLBCB610BH.DGN
SMLBCB611BH.DGN
SMLBCB612BH.DGN
SMLBCB613BH.DGN
SMLBCB614BH.DGN
SMLBCB615BH.DGN
SMLBCB616BH.DGN
SMLBCB617BH.DGN
SMLBCB618BH.DGN
SMLBCB619BH.DGN
SMLBCB620BH.DGN
SMLBCC101PP.DGN
SMLBCC102PP.DGN
SMLBCC103PP.DGN
SMLBCC104PP.DGN
SMLBCC105PP.DGN
SMLBCC106PP.DGN
SMLBCC107PP.DGN
SMLBCC108PP.DGN
SMLBCC111XS.DGN
SMLBCC112XS.DGN
SMLBCC113XS.DGN
SMLBCC114XT.DGN
SMLBCC115SR.DGN
SMLBCC116AR.DGN
SMLBCC117CC.DGN
188/425
188/470
SMLBCG002IS.DGN
SMLBCG003LS.DGN
SMLBCG004CD.DGN
SMLBCG005HC.DGN
SMLBCG006GN.DGN
C-16 188/426
SMLBCC118SA.DGN
SOIL CEMENT RAMPS
ACCESS ROAD AT STA 367+00 - PLAN AND PROFILE
CULVERT AT STA. 364+80 PLAN AND PROFILEC-17
C-18
188/427
188/428
SMLBCC109PP.DGN
SMLBCC110PP.DGN
FINAL GRADING - PLAN AND PROFILE STA 346+20 TO STA 351+00
FINAL GRADING - PLAN AND PROFILE STA 351+00 TO STA 356+40
FINAL GRADING - PLAN AND PROFILE STA 356+20.00 TO STA 364+00.00
FINAL GRADING - PLAN AND PROFILE STA 364+00.00 TO STA 373+00.00
FINAL GRADING - PLAN AND PROFILE STA 373+00.00 TO STA 380+00.00
SMLBCX501DT.DGN
188/442M-02 SMLBCX502CF.DGNPOST AND CABLE FENCE DETAILS
A
A
A
A
SIGNAGE, HYDRO-SEEDING AND MISC
AS SHOWN
J .U
J .U
E .K
T-02
IN
D
E X T
O C
O N
T R
A C
T D
R A
W
IN
G S
S M
L B
C G
IS
.D
G N
A R
E V
IS
E D I
N D
E X S
H E
E T
/1
/1
J .U
R e v
A
SAFETY PAYS
VALUE ENGINEERING PAYS
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
A P
P R
O V
A L
D A
T E
S Y
M B
O L
D E
S C
R
IP
T
IO
N S
U .S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
L O
S A
N G
E L E
S
C O
R P
S O
F E
N G
IN
E E
R S
R E
V
IS
IO
N S
D
IS
T R
IC
T F
IL
E N
O
S U
B M
IT
T E
D B
Y
C H
IE
F
D E
S
IG
N B
R A
N C
H
F
IL
E N
A M
E
12345678
A
B
C
D
12345678
A
B
C
D
_DATE_
Scale:
SHEET
Plot Date:
A R
T H
U R Y J
U N
G P
E
S P
E C
N O
W P
L -1
-B -0
S A
N T
A B
A R
B A
R A C
O U
N T
Y
C A
L
IF
O R
N
IA
S A
N T
A M
A R
IA
R
IV
E R B
A S
IN
S A
N T
A M
A R
IA
R
IV
E R A
N D T
R
IB
U T
A R
IE
S B
R A
D L E
Y C
A N
Y O
N L
E V
E E E
X T
E N
S
IO
N F
O R
E
E
295 295
295 295
295295
DIRT
300 300
300300300
200851
300.14
305 305
R O
C K
S 310 310310
310 310
8H
:1V
H :1
V
H :1
V
E X
IS
T
IN
G
STONE
PROTECTIONE
M
B A
N K
M E
N T
S O
IL
C
E M
E N
T
TOP OF EXISTING LEVEE
SOIL CEMENT
NOT TO SCALE
330330
330330
364+00355+00
S E
E C -0
S T
A
M
A T
C H L
IN
E
0 50 50 100FT
SCALE: 1’’= 50’
PLAN
PROFILE
0 10 10 20FT
VERT. SCALE: 1’’= 10’
0 50 50 100FT
HORIZ. SCALE: 1’’= 50’
CONSTRUCTION NOTES:
REFERENCE NOTES:
1.
FLOW
N
N ,1
,5
N ,1
,0
E 5,855,500
CREST OF LEVEE.
REMOVE TOP 6 INCHES OF MATERIAL FROM
4 5
E L
.5
B E
G
IN
S
O
IL
C
E M
E N
T
S T
A
.0
E L
.6
E N
D C
O M
B I-
W A
L L
S T
A
.0
EL 278.98
G R
A D
E B
R E
A K
S T
A
.0
G R
A D
E B
R E
A K
S T
A
.0
ROWPROJECT CL
FLOW LINE
TEMP CHANNEL
TOE OF SC
TOP OF SC
8 FT
12 FT–
LEVEE
EXISTING
STATION ELEVATION
355+70
359+05
294.00
294.13
295.15
OFFSET (FT)ID
364+00 296.714
355+32
RIVERBED
TOE AT
RIVERBED
TOE AT
TOE OF SC
TOP OF SC
LIMIT FOR SC
EXCAVATION
APPROX
E L E
V A
T
IO
N F
E E
T
E L E
V A
T
IO
N F
E E
T
SEE SHEET T-05 FOR PROJECT AND ROW CONTROL POINTS AND CURVE DATA.
C-01 AND C-02)
(SEE SHEETS
COMBI-WALL
PROPOSED
STA. TOP OF LEVEE
356+20
357+40
361+30 311.57
310.93
310.72310.90
311.00
311.60
TO CONSTRUCTION, PER SHEETS C-03 THROUGH C-05.
RELOCATE EXISTING LOW FLOW CHANNEL PRIOR(OFFSET FROM PROJECT CONTROL LINE)
FLOW LINE - TEMPORARY LOW FLOW
1.
NOTES:
LINE. SEE C-12 FOR DETAILS.
SHOWN ON PROFILE ARE PROJECTED ONTO THE CONTROL
TOP OF SC, TOE OF RIVERBED AND TOE OF SC LINEWORK
SEE SHEET C-14 FOR DETAILS.
TOP AND BOTTOM SOIL CEMENT ELEVATIONS.
EXISTING STONE PROTECTION. SEE PROFILE FOR
CONSTRUCT SOIL CEMENT LAYER OVER
SEE SHEET C-14 FOR DETAILS.
BASED ON ELEVATIONS GIVEN ON PROFILE.
BUILD CREST OF LEVEE WITH COMPACTED FILL
AS SHOWN
J .U
J .U
E .K
C-03
S T
A T
O S
T A
S O
IL
C
E M
E N
T P
L A
N A
N D P
R O
F
IL
E
S M
L B
C C
P
P .D
G N
CHANNEL
TEMP LOW FLOW
LIMIT FOR
EXCAVATION
APPROX
CHANNEL
LOW FLOW
EXISTING
S T
A M
A T
C H L
IN
E S
E E C -0
10%
15 FT
100-YR WSE
WSE
SPF
SPF WSE
TOP OF LEVEE AND
ELEVATIONS:
NOT BUILD THE ACCESS RAMP AS AN OVERLAY. SEE SHEET C-15.
REVETMENT IS CONSTRUCTED. THE CONTRACTOR SHALL
CEMENT RAMP AT THE SAME TIME AS TYPICAL
REMOVE EXISTING FILL ACCESS RAMP. CONSTRUCT SOIL
C-01 AND C-02)
(SEE SHEETS
COMBI-WALL
S T
A
S T
A
S T
A
SEE SHEET C-01 AND C-02 FOR DETAILS.
DRIVE STEEL COMBI-WALL ALONG TOP OF LEVEE.
LINE. SEE C-12 FOR DETAILS.
SHOWN ON PROFILE ARE PROJECTED ONTO THE CONTROL
TOP OF SC, TOE OF RIVERBED AND TOE OF SC LINEWORK 2.
AN 8H:1V. SEE SPECIFICATIONS FOR STONE GRADATION.
WIDTH (MATCHING SOIL CEMENT SURFACE) AT
(MATCHING EXISTING RIPRAP SURFACE) TO 8-FT
SOIL CEMENT. FLARE TRANSITION FROM 0-FT WIDTH
TRANSITION FROM EXISTING RIPRAP PROTECTION TO
TRANSITION HEREON
DOWNSTREAM
SEE DETAIL
DETAIL DOWNSTREAM TRANSITION
P .I .P
B U
IL
D
IN
G
A R
E M
O V
E A
N D R
E P
L A
C E E
X
IS
T
IN
G P
IP
E G
A T
E
A
SEE SHEET M-01 FOR DETAILS.
INSTALL PIPE GATE AT STA 358+40.
R E
V
A
A
PIPE GATE
REMOVE EXISTING
SAFETY PAYS
VALUE ENGINEERING PAYS
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
A P
P R
O V
A L
D A
T E
S Y
M B
O L
D E
S C
R
IP
T
IO
N S
U .S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
L O
S A
N G
E L E
S
C O
R P
S O
F E
N G
IN
E E
R S
R E
V
IS
IO
N S
D
IS
T R
IC
T F
IL
E N
O
S U
B M
IT
T E
D B
Y
C H
IE
F
D E
S
IG
N B
R A
N C
H
F
IL
E N
A M
E
12345678
A
B
C
D
12345678
A
B
C
D
_DATE_
Scale:
SHEET
Plot Date:
A R
T H
U R Y J
U N
G P
E
S P
E C
N O
W P
L -1
-B -0
S A
N T
A B
A R
B A
R A C
O U
N T
Y
C A
L
IF
O R
N
IA
S A
N T
A M
A R
IA
R
IV
E R B
A S
IN
S A
N T
A M
A R
IA
R
IV
E R A
N D T
R
IB
U T
A R
IE
S B
R A
D L E
Y C
A N
Y O
N L
E V
E E E
X T
E N
S
IO
N F
O R
355+00 356+00 357+00 358+00 359+00 360+00 361+00 362+00 363+00 364+00
EL 280.04
EG ALONG CL
S=0.0015
EL 311.60
EL 279.60
TOE OF SC
TOP OF SC
S=0.0016S=0.0014
S=0.0026S=0.0037
S=0.0007
EL 311.00
EL 279.07
EL 312.31
TOE AT RIVERBED
V A
R
IE
S
T Y
P
1.5 H:1
V
.5
H :1
V
.7
H :1
V
H :1
V
.7 H :1
V
H :1
V
8H
:1V
H :1
V
9’-0" 9’-0"
C
VARIES SEE PLANSVARIES SEE PLANS
SEE PLANS
TOP OF LEVEE VARIES -
ELEVATION AND WIDTH OF
ROW
EXISTING LEVEE
EASEMENT
TEMPORARY CONSTRUCTION
SHEET PILE
"B
"A
N .H
A S
IB
2’-6"
(SEE NOTE #1 FOR COMBI-WALL PROPERTIES)
COMBI-WALL SYSTEM TYPE "A"
NOT TO SCALE.
PROJECT CONTROL LINE
NOT TO SCALE.
LEVEE AND
PROJECT CONTROL LINE
NOT TO SCALE.
1:1
(PROTECT IN PLACE)
EXISTING COMBI-WALL
CONNECTOR
BBS-F
CONNECTOR
BBS-M
COMBI-WALL DETAIL AT STA. 346+20
TYPICAL COMBI-WALL PLAN DETAIL
N .H
A S
IB
T .W
O N
G
1 1FT
SCALE: 1 1/2’’= 1’-0’’
0 1 1
SCALE: 1’’=1’-0’’
2FT
A
C-01 S-02
B
S-02
S-02
C-C
S-02
S H
E E
T P
IL
E W
A L L D
E T
A
IL
S
S M
L B
C S
D T .D
G N
WIDE FLANGE BEAM
(SEE NOTE #2 FOR WIDE FLANGE BEAM PROPERTIES)
WIDE FLANGE BEAM TYPE "B"
4" ABC
FLANGE BEAM SHALL NOT EXCEED 4 IN.
EXISTING PIPE PILE AND THE NEAREST PART OF THE WIDE
WITH THE EXISTING PIPE PILE. THE DISTANCE BETWEEN THE
LINE. THE WIDE FLANGE BEAM SHALL NOT BE IN CONTACT
WIDE FLANGE BEAM @ 12.5 DEG. FROM THE PROJECT CONTROL
C-01 C-02
C-01 C-02
A
IN
S E
R T
E D N
O T
E
/1
/1
T .W
A
ALTERNATIVE TO WELDED CONNECTORS WILL NOT BE ACCEPTED.9.
REQUIREMENTS OF AWS D1.1.
WITH THE MANUFACTURERS RECOMMENDATION AND SHALL CONFORM TO THE
BEAM CONTINUOUSLY THE FULL LENGTH OF SHEET PILE IN ACCORDANCE
BBS-M AND BBS-F CONNECTORS TO BE WELDED ON THE WIDE FLANGE8.
ASTM A572, GRADE 50, UNLESS APPROVED OTHERWISE.
THE WIDE FLANGE BEAM MATERIAL SHALL MEET THE REQUIREMENT OF 7.
ASTM A572, GRADE 50, UNLESS APPROVED OTHERWISE.
AND BARS SHALL CONFORM TO THE REQUIREMENTS OF
ALL STRUCTURAL CARBON STEEL ROLLED SHAPES, PLATES,6.
THE CONTRACTOR.
NOT EXTEND BEYOND IT AT THE SOLE EXPENSE OF
WITHIN THE FOOTPRINT OF THE EXISTING LEVEE AND
DISTURBED STONE PROTECTION SHALL BE RESTORED
STONE PROTECTION ON EXISTING LEVEE SLOPE. ANY
CONTRACTOR TO TAKE CARE NOT TO DISTURB THE5.
COMPACTION IN ACCORDANCE WITH ASTM D1557.
BACKFILL SHALL BE COMPACTED TO 90% RELATIVE
TO PLACEMENT OF 4" ABC.
WITHIN WIDE FLANGE BEAMS AND SHEET PILES PRIOR
AND COMPACT LOCAL AREAS OF SUBSIDENCE AROUND AND
CONTRACTOR TO BACKFILL WITH SATISFACTORY MATERIAL 4.
CHOSEN METHOD OF INSTALLATION.
FINAL PILE SIZE THAT IS COMPATIBLE WITH THE CONTRACTOR’S
THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DETERMINING THE
METHODS REQUIRED TO REACH THE PENETRATION DEPTH INDICATED.
THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DETERMINING THE
ALLOW FOR ANY STRESSES INDUCED DURING PILE INSTALLATION.
LISTED ABOVE, THE PILING SHALL BE SUFFICIENTLY SIZED TO
IN ADDITION TO THE MINIMUM SECTION PROPERTIES3.
SECTION MODULUS S=854 IN
MOMENT OF INERTIA I=15600 IN
THE PENETRATION DEPTH
WIDE FLANGE BEAM "B" IS THE WIDE FLANGE BEAM OF SYSTEM "A" EXTENDING TO
REQUIRED MINIMUM PROPERTIES OF THE WIDE FLANGE BEAM "B"2.
/FT.
SECTION MODULUS S=159 IN
/FT.
MOMENT OF INERTIA I=3124 IN
COMBI WALL SYSTEM "A" INCLUDES THE WIDE FLANGE BEAM AND THE SHEET PILE
REQUIRED MINIMUM PROPERTIES OF COMBI-WALL SYSTEM "A"1.
NOTES:
R E
V
A
S A
N T
A B
A R
B A
R A C
O U
N T
Y
C A
L
IF
O R
N
IA
S A
N T
A M
A R
IA
R
IV
E R B
A S
IN
SAFETY PAYS
VALUE ENGINEERING PAYS
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
A P
P R
O V
A L
D A
T E
S Y
M B
O L
D E
S C
R
IP
T
IO
N S
U .S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
L O
S A
N G
E L E
S
C O
R P
S O
F E
N G
IN
E E
R S
R E
V
IS
IO
N S
D
IS
T R
IC
T F
IL
E N
O
S U
B M
IT
T E
D B
Y
C H
IE
F
D E
S
IG
N B
R A
N C
H
F
IL
E N
A M
E
12345678
A
B
C
D
A R
T H
U R Y J
U N
G P
E
12345678
A
B
C
D
Scale:
SHEET
Plot Scale:
S P
E C
N O
W P
L -1
-B -0
S A
N T
A M
A R
IA
R
IV
E R A
N D T
R
IB
U T
A R
IE
S B
R A
D L E
Y C
A N
Y O
N L
E V
E E E
X T
E N
S
IO
N F
CONTRACTING OFFICER WILL IDENTIFY MONUMENT NUMBER.
METAL STAMPING OUTFITS SHALL BE USED FOR STAMPING LETTERS AND NUMBERS.
1.
2.
3.
4.
F
T
FINAL GRADING
NUMBER HERE
STAMP MONUMENT
DISTRICT" HERE
STAMP "L.A.
YEAR HERE
STAMP PLACEMENT
3.5"
C O
R P S
O F
E
NGINEERS - U
.S . A
R M
Y
SURVEY MARKSURVEY MARK
F
IN
E
OR IMPRIS
O
N M
E N
T
F
D
IS
TURBING
TH
IS
M A
R K
SM-2
S T A
T
ION DESIGNAT
IO
N
AGENCY
L.A. DISTRIC
T
YEAR 2009
SHALL INSTALL SURVEY MARKERS.
CONTRACTING OFFICER SHALL FURNISH BRONZE SURVEY MARKERS. CONTRACTOR
SHALL INSTALL THE SURVEY MARKERS.
CONTRACTING OFFICER SHALL DETERMINE LOCATIONS WHERE THE CONTRACTOR BRONZE SURVEY MARKER
BRONZE SURVEY MARKER
AS SHOWN
M-01
J .U
E .K
S M
L B
C X
D T .D
G N
J .U
S
IG
N A
G E
H Y
D R
O -S
E E
D
IN
G A
N D M
IS
C
A R
E V
IS
E D S
H E
E T T
IT
L E A
D D
E D P
IP
E G
A T
E D
E T
A
IL
/1
/1
J .U
A
R E
V
A
A
A A
SAFETY PAYS
VALUE ENGINEERING PAYS
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
A P
P R
O V
A L
D A
T E
S Y
M B
O L
D E
S C
R
IP
T
IO
N S
U .S
A R
M Y E
N G
IN
E E
R D
IS
T R
IC
T
L O
S A
N G
E L E
S
C O
R P
S O
F E
N G
IN
E E
R S
R E
V
IS
IO
N S
D
IS
T R
IC
T F
IL
E N
O
S U
B M
IT
T E
D B
Y
C H
IE
F
D E
S
IG
N B
R A
N C
H
F
IL
E N
A M
E
12345678
A
B
C
D
12345678
A
B
C
D
_DATE_
Scale:
SHEET
Plot Date:
A R
T H
U R Y J
U N
G P
E
S P
E C
N O
W P
L -1
-B -0
S A
N T
A B
A R
B A
R A C
O U
N T
Y
C A
L
IF
O R
N
IA
S A
N T
A M
A R
IA
R
IV
E R B
A S
IN
S A
N T
A M
A R
IA
R
IV
E R A
N D T
R
IB
U T
A R
IE
S B
R A
D L E
Y C
A N
Y O
N L
E V
E E E
X T
E N
S
IO
N F
O R
E D
G E O
F S
O
IL
C
E M
E N
T
6 FT (MIN)
F
T
M
IN
30 IN
I
N I
N
BOLTS
SOIL CEMENT
4-IN ABC
DETAIL HEREON
SEE FOUNDATION
FOUNDATION DETAIL
WARNING SIGN
* = END POST 1 1/2 IN ABOVE BOLT HOLE
NOT TO SCALE
NOT TO SCALE
I N
0 20 40 50-20-40-60-80-100-120-140-160-180-200
C
PROJECT
L
L
HYDRO-SEED HYDRO-SEED
SEED
HYDRO-
NO
15 FTVARIES VARIES
GRADE
FINAL
VARIES
C
FLOW
LOW
TYPICAL HYDRO-SEEDING AREAS
CHANNEL BED, 120 FT–
HYDRO-SEEDING ACREAGE:
15 FT
NO HYDRO-SEED
(STA 356+20 THROUGH STA 380+00)
FROM 355+00 THROUGH 383+00 (5.4 ACRES).
- HYDRO-SEED DISTURBED CHANNEL BED, AS SHOWN ON CROSS-SECTION,
I
N
I
N
I N
I N
I N
12 IN
F O
U N
D A
T
IO
N S
L E
E V
E
SOIL CEMENT
SOIL CEMENT
FOOTING
CONCRETE
SEE DETAIL A
UNDER HEAD
NUT AND FLAT WASHER
LOCK WASHER UNDER
BOLT W/ FLAT AND
PLATED HEX. HEAD
IN CAD.2
IN X 3 8
FLOW
CRITICAL TRAFFIC
TO MAJOR OR
PERPENDICULAR
BOLT SHALL BE
NOT TO SCALE
DETAIL A
14 FT8FT6FT
N O H
Y D
R O -S
E E
D
N O H
Y D
R O -S
E E
D
H Y
D R
O -S
E E
D
GENERAL NOTES:
SURVEY MARKER
#6 REBAR
FILLED WITH EPOXY
NOT TO SCALE
PLAN VIEW
ELEVATION VIEW
NOT TO SCALE
18"
NOT TO SCALE
24"
NOT TO SCALE
GATE POST DETAIL
(Typ)
Pipe Gate
Typical
R=2"
(Typ)
Latch Post
NOT TO SCALE
POST LOCATION DETAIL
GATE POST
LATCH POST
LATCH POST
15’-0"–
7’-3"–
POST CONCRETE FILLED
GATE POST/BEARING
GALVANIZED STEEL
6" DIA. SCHDL 40
POST DETAIL
SEE GATE
OF GATE
8" AT CENTER
ALL JOINTS
1/4" TYPICAL
3" (MIN)
3" (MIN)
TO GATE AND LATCH POST
SHOWN AND WELDED
2- 1/2" ROD BENT AS
PIPE GATE
ELEVATION
PIPE GATE (STA 358+40)
(TYP)
2500 PSI CONCRETE
(TYP)
GALV. PIPE GATE
SCHEDULE 40
2" DIA.
12"
SOIL CEMENT
PIPE GATE WIDTH = 14’-6"–
T O
P O
F L
E V
E E W
ID
T
H
GATE WIDTH ACCORDINGLY
LEVEE WIDTH AND ADJUST PIPE
*FIELD VERIFY FINAL TOP OF
12"
(2 POST REQUIRED)
POST CONC. FILLED
GALV. STEEL LATCH
4" DIA. SCHDL 40
STATION
W16-7pL
W5-1
MUTCD CODE
SIGNAGE
W16-7pL
W5-1
356+00
356+70
379+30
380+00
HAS SET
AFTER CONCRETE
FOUNDATION SLEEVE
REMOVABLE FROM
POSTS SHALL BE
FLOWTRAFFI
C
| T-02 |
| Saved Views |
| ALL |
| References |
| Sht1, .. |
| Ref |
| bdrsht3d.dgn |
| C-03_Rev A |
| Saved Views |
| Sheet |
| References |
| Sht1, .. |
| Ref |
| bdrsht3d.dgn |
| Parcel Map.dgn |
| .. |
| Ref |
| Grid.dgn |
| 08834 V8 40 COE.DGN |
| Alignment.DGN |
| plan.DGN |
| Utilities&Features.DGN |
| TopoPartial.DGN |
| LowFlowTemp.DGN |
| prof-1, .. |
| Ref |
| Profile.DGN |
| S-02-Rev A |
| Saved Views |
| ALL |
| SHT |
| References |
| S-02-Rev A.dgn |
| BORDERSHT2D.dgn |
| Ref, S-02-Rev A.dgn |
| Top1, W40x249C13.dgn, Model |
| M-01_Rev A |
| Saved Views |
| SHT |
| References |
| Sht1, .. |
| Ref |
| bdrsht3d.dgn |