Drawings_W912PL12R0003_SQ_OPS_VOL_1.pdf
PDF 36 MB Posted
- Solicitation number
- W912PL-12-R-0003
About this file
DRAWINGS - VOLUME 1 - F-35 SQUADRON OPERATIONS FACILITY
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Am5_W912PL-12-R-0003.pdf | ||
| Am4_W912PL-12-R-0003.pdf | ||
| Squad Ops AMU Attendance List.pdf | ||
| Am3_W912PL-12-R-0003.pdf | ||
| Am2_W912PL-12-R-0003.pdf | ||
| Am1_W912PL-12-R-0003.pdf | ||
| SPL012-11.pdf | ||
| SPL012-12.pdf | ||
| SPL012-10REVISED.pdf | ||
| SPL012-9.pdf | ||
| SPL12-10.pdf | ||
| SPL012-12.pdf | ||
| SPL012-11.pdf | ||
| SPL012-9.pdf | ||
| Spec_W912PL-12-R-0003V2.pdf | ||
| Drawings_W912PL12R0003_SQ_OPS_VOL_2 .pdf | ||
| Spec_W912PL-12-R-0003V3.pdf | ||
| Spec_W912PL-12-R-0003V1.pdf | ||
| Drawings_W912PL12R0003_ADAL AMU.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATED :
MARICOPA COUNTY, ARIZONA
56th FIGHTER WING, LUKE AFB
SOLICITATION NO. : W912PP-10-D-0007
TASK ORDER NO.: 0002
12 JANUARY 2012
J S
F S
Q U
A D
R O
N O
P E
R A
T
IO
N S
S
Q O
P S
F-35 SQUADRON OPERATIONS
SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENDATION AND
APPROVAL OF ALL DRAWINGS IN THIS SET AS INDEXED.
SUBMITTED:
CHIEF, DESIGN BRANCH
APPROVED:
CHIEF, ENGINEERING AND CONSTRUCTION DIVISION
THE INITIALS OR SIGNATURES AND REGISTRATION DESIGNATIONS OF
GOVERNMENT INDIVIDUALS APPEAR ON THESE PROJECT DOCUMENTS
WITHIN THE SCOPE OF THEIR EMPLOYMENT AS REQUIRED BY ER 1110-1-8152.
PLANS FOR
FACILITY (SQ OPS)
BURNS & McDONNELL
KANSAS CITY MO 64114
(816) 333-9400
9400 WARD PARKWAY
ISSUED FOR BID
OPTIONAL ITEM 1
OPTIONAL ITEM 2
OPTIONAL ITEM 3
OPTIONAL ITEM 4
OPTIONAL ITEM 5
OPTIONAL ITEM 6
OPTIONAL ITEM 7
BID OPTIONS
100 KW AC PV ARRAY
PRE-WEATHERED STEEL WALL FINISH
PRE-WEATHERED STEEL CANOPIES
TRANSLUCENT PANELS
FURNITURE FIXTURES & EQUIPMENT (FF&E)
FUNDAMENTAL COMMISSIONING
ENHANCED COMMISSIONING
United States Army Corps of Engineers ...Serving the Nation ...Serving the Army
VOLUME 1
Los Angeles District
F-35 SQUADRON OPERATIONS FACILITY
W912PL-12-R-0003
PROJECT NO.: NUEX093001A
t h
F
I G
H T
E R
W
I N
G
L U
K
A
F B
G
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
N S
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
M c D
P
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L E
S
C
A L I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
C
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
DWG # DRAWING TITLE
O
F
I N
D E
X
S
H E
E T
G-001
SEQUENCE # DWG # DRAWING TITLESEQUENCE # DWG # DRAWING TITLESEQUENCE #
t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L E
S
C
A L I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
O
F
I N
D E
X
S
H E
E T
G-002
DWG # DRAWING TITLESEQUENCE # DWG # DRAWING TITLESEQUENCE #
t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
1 23
C-001
V
L
G
E N
D
A
B
R E
V I A
T I O
N S
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
N O
T
T
O
S
C A
SHEET SEQUENCE NUMBER
INDICATES WHERE TITLE IS
LOCATED (MAY NOT BE
PRESENT IF CALLOUT AND
TITLE ARE ON THE SAME
SHEET)
LETTER OR
NUMBER DESIGNATOR
THE WORD "SECTION"
MAY BE REPLACED WITH
"ELEVATION" OR "DETAIL"
ONE OR TWO CHARACTER
DISCIPLINE DESIGNATOR
(MAY NOT BE PRESENT IF
CALLOUT AND TITLE ARE
ON DRAWINGS WITHIN THE
SAME DISCIPLINE)
DETAIL CALLOUT EXAMPLESECTION CALLOUT EXAMPLE
SECTION, DETAIL, OR ELEVATION TITLE EXAMPLE
SECTION, DETAIL, AND ELEVATION
SYMBOL IDENTIFIERS
SECTION, DETAIL, AND ELEVATION IDENTIFICATION SYSTEM
C001
A
C001
A
SECTION
C001
C001
A
C001
A
BRASS CAP IN HANDHOLE
R/8" REBAR WITH ALUMINUM CAP
60D NAIL
FIRE HYDRANT
WATER VALVE
BACKFLOW PREVENTER
BLOWOFF VALVE
WATER METER
FIRE DEPARTMENT CONNECTION
DRAIN PIPE (SIZE AS NOTED)
WATER SPIGOT
WATER SPRINKLER
SANITARY SEWER MANHOLE
SEWER CLEANOUT
DRYWELL
GRATE
STORM DRAIN MANHOLE
ROOF DRAIN
ELECTRIC TRANSFORMER
ELECTRIC MANHOLE
ELECTRIC PULL BOX
ELECTRIC JUNCTION BOX
ELECTRIC PANEL
UTILITY POLE
GUY WIRE
LIGHT POLE
STREET LIGHT
BUILDING LIGHT
GAS METER
GAS VALVE
IRRIGATION CONTROL VALVE
TELEPHONE MANHOLE
TELEPHONE RISER
CABLE TV BOX
MISCELLANEOUS (AS NOTED)
UNKNOWN MANHOLE
BOLLARD
FLAG POLE
SIGN
TREE (DIAMETER IN INCHES)
MESQUITE TREE (DIAMETER IN INCHES)
PALM TREE (DIAMETER IN INCHES)
CACTUS (TYPE, DIAMETER IN INCHES)
SAGUARO
BUSH (DIAMETER IN INCHES)
ROCK (DIAMETER IN INCHES)
ROOF ELEVATION
FINISH FLOOR ELEVATION
TOP OF NUT ELEVATION
TOP OF CURB ELEVATION
GUTTER ELEVATION
PAVEMENT ELEVATION
CONCRETE ELEVATION
GROUND SPOT ELEVATION
WALL
CHAINLINK FENCE
WROUGHT IRON FENCE
WATER BLUESTAKE MARKING
SEWER BLUESTAKE MARKING
ELECTRIC BLUESTAKE MARKINGS
GAS BLUESTAKE MARKINGS
TELEPHONE BLUESTAKE MARKINGS
COMMUNICATION BLUESTAKE MARKINGS
ELECTRIC TRENCH
RIPRAP
D
FO
T
G
E
S
W
OR EQUIPMENT CABINET
SURVEY LEGEND: PROPOSED LEGEND: ABBREVIATIONS
CONTOUR
BENCHMARK / CONTROL
POINT LOCATION
BORING LOCATION
CENTERLINE
PAVEMENT LIMIT
CURB AND GUTTER
SIDEWALK PAVERS
BUILDING AND STRUCTURE
TREES AND SHRUBS
COMPACTED SUBGRADE
GRADED CRUSHED AGGREGATE
BASE COURSE
ASPHALT PAVEMENT
SILT FENCE
BALES
WADDLE / LOGS
CLEAN OUT
MANHOLE
DRAIN OR INLET
VALVE
POST INDICATOR VALVE
CAP
SPOT ELEVATION
SIGN
FIRE HYDRANT
MATCH LINE
DEMOLITION OR REMOVAL
UTILITY DEMOLITION
BOLLARD
ASPHALT DEMOLITION
CONCRETE DEMOLITION
MISCELLANEOUS DEMOLITION
BUILDING DEMOLITION
NORTH ARROW
CONCRETE PAVEMENT
EARTH
SWING GATE
WALL
WATER LEVEL
FLOW LINE
CURB INLET
SAWCUT
DEMOLITION BY OTHERS
ABS
AC
AFB
AGA
ATC
AT/FP
AVE
BAR
BLDG
BM
BMP
BOC
B/W
CHO
CP
CI
CL
CO
COMM
CMU
CI
CWR
CWS
DIA
DIP
DR
E
EL/ELEV
EX
EU
F
FDPC
FF
FH
FL
FO
FOD
G
GEN
HWR
HWS
ID
IN
INF
INV
JSF
LEED
LF
LN
MAG
MESQ
MIN
N
NAVD
NIC
NO
OD
OCO
OHE
POC
PCC
PE
PIV
PP
PVC
R
RCP
RD
RECEPT
S
SEC
S/SS
SD
SDMH
SF
SSMH
SWPP
ST
STA
SW
T/C
TG
TI
TP
T/W
TYP
UTO
VCP
VLT
W
ARIZONA BLUE STAKE
ASPHALTIC CONCRETE PAVEMENT/AIR CONDITIONER
AIR FORCE BASE
AGAVE
ACADEMIC TRAINING CENTER
ANTI-TERRORISM FORCE PROTECTION
AVENUE
BARREL
BUILDING
BENCHMARK
BEST MANAGEMENT PRACTICES
BACK OF CURB
BOTTOM OF WALL ELEVATION
CHOLLA
CATHODIC PROTECTION
CAST IRON
CENTER LINE
CLEAN OUT
COMMUNICATIONS
CONCRETE MASONRY UNIT
CURB DRAINAGE INLET
CHILLED WATER RETURN
CHILLED WATER SUPPLY
DIAMETER
DUCTILE IRON PIPE
DRIVE
EAST/EASTING/ELECTRIC
ELEVATION
EXISTING
UNDERGROUND ELECTRIC
FIRE WATER
FIRE DEPARTMENT PUMPER CONNECTION
FINISH FLOOR
FIRE HYDRANT
FLOW LINE ELEVATION
FIBER OPTIC
FOREIGN OBJECT DAMAGE
NATURAL GAS
GENERATOR
HOT WATER RETURN
HOT WATER SUPPLY
INSIDE DIAMETER / INDENTIFICATION
INCHES
INFRASTRUCTURE
INVERT
JOINT STRIKE FIGHTER
LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN
LINEAR FEET
LANE
MARICOPA ASSOCIATION OF GOVERNMENTS
MESQUITE
MINIMUM
NORTH/NORTHING
NORTH AMERICAN VERTICAL DATUM
NOT IN CONTRACT
NUMBER
OUTSIDE DIAMETER
OCOTILLO
OVERHEAD ELECTRIC
POINT OF CONTACT
PORTLAND CEMENT CONCRETE
POLYETHYLENE
POST INDICATOR VALVE
PRICKLY PEAR
POLYVINYL CHLORIDE
RADIUS
REINFORCED CONCRETE PIPE
ROOF DRAIN / ROAD
RECEPTACLE
SOUTH
SECTION
SANITARY SEWER
STORM DRAIN
STORM DRAIN MANHOLE
SQUARE FEET
SANITARY MANHOLE
STORM WATER POLLUTION PREVENTION
STREET
STATION
SOUTHWEST
TOP OF CURB ELEVATION
TOP OF GROUND ELEVATION
TOP OF INLET ELEVATION
TOP OF PAVEMENT ELEVATION
TOP OF WALL ELEVATION
TYPICAL
UNABLE TO OPEN
VITRIFIED CLAY PIPE
VAULT
WATER/WEST
t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
2 23
C-002
V
N
E R
O T
E S
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
GENERAL NOTES:
1. ALL DIMENSIONS, ELEVATIONS, AND STATIONS ARE IN FEET, UNLESS INDICATED OTHERWISE.
2. CALLOUTS, COORDINATES, AND DIMENSIONS ARE POINTED TO OR MEASURED TO STRUCTURE
CENTER, EDGE OF PAVEMENT, BACK OF CURB, OR OUTSIDE FACE OF FOUNDATION WALL, UNLESS
INDICATED OTHERWISE.
3. ALL WORK SHALL BE CONDUCTED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND
LOCAL AND GOVERNMENT CODES, ORDINANCES, AND REGULATIONS. IN CASE OF CONTRADICTION
OR DISCREPANCY BETWEEN REQUIREMENTS, CONTRACTOR SHALL INCORPORATE WHICHEVER IS
MOST STRINGENT. WHERE A QUESTION REMAINS ON WHICH REQUIREMENT IS MOST STRINGENT,
CONTRACTOR SHALL SUBMIT ISSUE TO THE CONTRACTING OFFICER'S REPRESENTATIVE IN
WRITING. THE DECISION OF THE CONTRACTING OFFICER'S REPRESENTATIVE SHALL BE
CONSIDERED FINAL.
STORM WATER POLLUTION PREVENTION PLAN (SWPPP)
1. CONTRACTOR IS RESPONSIBLE FOR OBTAINING A STORM WATER PERMIT FOR LAND DISTURBANCE
OF MORE THAN 1 ACRE PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR
COORDINATING WITH LOCAL AUTHORITIES TO COMPLETE AND SUBMIT THE STORM WATER
POLLUTION PREVENTION PLAN (SWPPP) FOR APPROVAL. LOCAL AUTHORITIES INCLUDE BUT ARE
NOT LIMITED TO COUNTY AND CITY STORMWATER MANAGEMENT GROUPS. CONTRACTOR SHALL
COORDINATE ALL ENVIRONMENTAL AND STORM WATER CORRESPONDENCE, DOCUMENTATION,
AND PERMITTING WITH CONTRACTING OFFICER'S REPRESENTATIVE. THE STORMWATER
PERMITTING PROCESS MAY INCLUDE THE FOLLOWING:
a. SUBMIT STORM WATER QUALITY PERMIT APPLICATION FEE.
b. SUBMIT NPDES GENERAL CONSTRUCTION PERMIT.
c. SUBMIT STORM WATER POLLUTION PREVENTION PLAN.
d. SUBMIT AFFIDAVIT STATING PROPERTY OWNER'S COMMITMENT TO COMPLY WITH STORM
WATER QUALITY MANAGEMENT PLAN AND LOCAL REGULATIONS FOR STORM WATER QUALITY
MANAGEMENT.
e. SUBMIT COPY OF APPROVED PROJECT DRAWING SET.
ACCESS AND SAFETY PLAN
J E
R S
T A
D
L A
N E
H O
M E
R
D
R
F I G
H T
U
N T
Y
V E
W. MUSTANG ST.
A I R
F I E
R
V I C
E
R
O A
D
565 567
663 673
B O
FALCON ST.
EAGLE ST.
W. PHANTOM ST.
W
. SHOOTING STAR ST.
N t h
D
R
H A
R R s t
A
V E
B O
N
H
A R
R
N t h
D
R
N s t
A
V E
N
H
O M
N
L I T
C H
F I E
530528
26 25
CONTRACTOR
HAUL ROUTE
ALTERNATE CONTRACTOR
STAGING AREA
BORROW PIT
NORTHERN AVENUE
CORSAIR ST.
R
U
N
W
PRIMARY ATC
CONTRACTOR
STAGING AREA
BASE
SECURITY
OFFICE
PASS AND ID
BASE
ENTRANCE
(SOUTH GATE)
J O
H N
S O
N
L N
CONTRACTOR ACCESS ROUTE
SUPER SABRE ST
H A
R R
T
A
X
I
W
T
A
X
I
W
A
X I W
A
X I W
THUNDERBIRD
MITCHELL ST
MARAUDER ST
L
I
G
H
T
I
BASE ENTRANCE
(NORTH GATE)
FIRE DEPARTMENT B450
GILLESPIE DR.
t h
D
R
SPAD ST.
T O
V R
S H
U B r d
A
V E
STARFIGHTER ST.
3 23
C-003
C E
F
E T
Y
P
L A
N
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
N O
T
T
O
S
C A
TUCSON
CHANDLER
SCOTTSDALE
MESA
PHOENIX
ARIZONA
NEW MEXICO
MEXICO
CALIFORNIA
GULF OF
CALIFORNIA
PROJECT
VICINITY
PEORIA
GLENDALE
PHOENIX
MESA
TEMPE
SCOTTSDALE
GLENDALE
VICINITY MAP
LOCATION PLAN
NOT TO SCALE
NOT TO SCALE
PHOENIX SKY HARBOR
INTERNATIONAL AIRPORT
LUKE AIR FORCE BASE
F-35 ACADEMIC TRAINING
CENTER PROJECT LOCATION
FIGHTER COUNTRY AVE.
FIGHTER COUNTRY AVE.
W. GLENDALE AVENUE
N. LITCHFIELD ROAD
t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
W
EST GLENDALE
AVENUE
116± 458±
PRIMARY SQUADRON
OPERATIONS STAGING
AREA
ALERNATE ATC CONTRACTOR
STAGING AREA
SQUADRON OPERATIONS
PROJECT LOCATION
BUILDING
BUILDING 462
BUILDING 431
N 923600 t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
EXISTING CONDITIONS PLAN - 1 OF 2
CONTROL POINTS
POINT NORTHING EASTING ELEV. DESCRIPTION
8 923699.7570 563092.2920 1075.00
116 923789.3660 563374.0700 1075.36
ALUMINUM CAP GDACS
POINT 30708R-2
SET PK NAIL
SURVEY AND SUBSURFACE INVESTIGATION NOTES :
1. THE SURVEY WAS PERFORMED BY STANTEC CONSULTING SERVICES, INC. IN OCTOBER-NOVEMBER 2010. SURVEY CONTROL
POINTS SHALL BE PROVIDED PRIOR TO CONSTRUCTION AND SHALL BE RESET BY THE CONTRACTOR IF DISTURBED DURING
CONSTRUCTION.
HORIZONTAL DATUM - THE COORDINATES SHOWN ON THIS SURVEY ARE BASED ON NAD 83 STATE PLANE COORDINATE SYSTEM, ARIZONA CENTRAL ZONE, INTERNATIONAL FEET CONVERTED TO GROUND VALUES AT A SCALE ORIGIN POINT OF X=565462.4580, Y=923158.7520.
(BRASS CAP IN HANDHOLE AT INTERSECTION OF LITCHFIELD ROAD AND GLENDALE AVENUE) USING A COMBINATION SCALE
FACTOR OF 1.0001261022.
VERTICAL DATUM - NAVD 1988.
2. CONTRACTOR SHALL RETAIN A LICENSED SURVEYOR TO SURVEY PROJECT IMPROVEMENTS. IF BENCHMARKS SHOWN ARE IN
AREAS THAT REQUIRE DEMOLITION, OTHER BENCHMARKS SHALL BE ESTABLISHED BEFORE DEMOLITION AND CONSTRUCTION
WORK BEGINS. CONTRACTOR SHALL SUPPLY CERTIFIED, CONTROL POINT DATA TO CONTRACTING OFFICER'S REPRESENTATIVE
AFTER COMPLETION OF CONSTRUCTION.
3. THE GEOTECHNICAL INVESTIGATION WAS PERFORMED BY KLEINFELDER FROM NOVEMBER 2010 TO MARCH 2011. THE RESULTS OF
THE INVESTIGATION ARE CONTAINED IN THE GEOTECHNICAL EXPLORATION REPORT AND ADDENDA.
4. BM ELEV. = 1078.31 BRASS CAP IN HANDHOLE LOCATED AT THE NORTHEAST CORNER OF SECTION 9, TOWNSHIP 2 NORTH, RANGE 1
WEST, IN THE INTERSECTION OF LITCHFIELD ROAD AND GLENDALE AVENUE, MARICOPA COUNTY DATUM, NAVD 88. A PORTION OF
SECTION 4 AND A PORTION OF THE NORTH HALF OF SECTION 9, TOWNSHIP 2 NORTH, RANGE 1 WEST OF THE GILA AND SALT RIVER
BASE AND MERIDIAN, MARICOPA COUNTY, ARIZONA.
5. THERE ARE NO EASEMENTS ON SUBJECT PROPERTY PER CONDITION OF TITLE REPORT BY CHICAGO TITLE INSURANCE COMPANY
WITH AN EFFECTIVE DATE OF OCTOBER 12, 2010, ORDER NO. CT1021936.
6. BASIC UTILITIES (WATER, SEWER, STORM DRAIN, ELECTRIC AND GAS) ARE LUKE AFB OWNED AND SELF PROVIDED. QWEST
COMMUNICATIONS AND COX CABLE IS WITHIN THE PROJECT.
MATCHLINE -- SEE SHEET C-012 FOR CONTINUATION
BUILDING 431
BUILDING 460
EXISTING CONDITIONS NOTES:
1. THE LOCATIONS OF STRUCTURES AND UNDERGROUND UTILITIES AS INDICATED HAVE BEEN
OBTAINED FROM EXISTING RECORDS AND FIELD SURVEYS. UNDERGROUND STRUCTURES AND
UTILITIES MAY BE PRESENT WHICH ARE NOT DOCUMENTED OR LOCATED.
2. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FIELD-VERIFY EXISTING STRUCTURES, UTILITIES, SERVICE CONNECTIONS, AND SURVEY INFORMATION, AND TO TAKE NECESSARY
PRECAUTIONS DURING DEMOLITION AND CONSTRUCTION. ANY DISCREPANCIES IN THE
DRAWINGS SHALL BE IMMEDIATELY REPORTED TO THE CONTRACTING OFFICER'S
REPRESENTATIVE BEFORE ANY FURTHER WORK COMMENCES. CONTRACTOR SHALL CONTACT
THE CONTRACTING OFFICER'S REPRESENTATIVE AND ALL ASSOCIATED UTILITY COMPANIES AND
AGENCIES TO IDENTIFY THE LOCATION OF UTILITIES. THERE IS NO GUARANTEE, EITHER
EXPRESSED OR IMPLIED, THAT THE LOCATIONS, SIZE AND TYPE OF MATERIAL OF EXISTING
UNDERGROUND UTILITIES INDICATED ARE REPRESENTATIVE OF THOSE TO BE ENCOUNTERED
DURING CONSTRUCTION.
3. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ITEMS NOT TO BE DAMAGED DURING
DEMOLITION AND CONSTRUCTION. THE CONTRACTOR SHALL REPAIR OR REPLACE DAMAGED OR
DISTURBED ITEMS TO THE SATISFACTION OF THE CONTRACTING OFFICER'S REPRESENTATIVE.
4 23
C-011
X
I S
T I N
G
C
O N
D I T
I O
A
N
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
O
BUILDING
N 923400
N 923200 t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
EXISTING CONDITIONS PLAN - 2 OF 2
CONTROL POINTS
POINT NORTHING EASTING ELEV. DESCRIPTION
5 923232.5240 563144.3420 1074.99
923158.7520 565462.4580 1078.31
111 923276.0120 563375.9780 1074.91
113 923123.1650 563119.5190 1074.29
114 923471.2980 563309.6340 1074.47
115 923463.6850 563100.1610 1074.39
3641 923056.0480 563354.4820 1076.18
4154 923262.4590 563321.5800 1074.70
SET PK NAIL
SET PK NAIL
SET PK NAIL
SET PK NAIL
SET PK NAIL
SET PK NAIL
ALUMINUM CAP GDACS
POINT 30708R-1
SURVEY AND SUBSURFACE INVESTIGATION NOTES :
1. THE SURVEY WAS PERFORMED BY STANTEC CONSULTING SERVICES, INC. IN OCTOBER-NOVEMBER 2010. SURVEY CONTROL
POINTS SHALL BE PROVIDED PRIOR TO CONSTRUCTION AND SHALL BE RESET BY THE CONTRACTOR IF DISTURBED DURING
CONSTRUCTION.
HORIZONTAL DATUM - THE COORDINATES SHOWN ON THIS SURVEY ARE BASED ON NAD 83 STATE PLANE COORDINATE
SYSTEM, ARIZONA CENTRAL ZONE, INTERNATIONAL FEET CONVERTED TO GROUND VALUES AT A SCALE ORIGIN POINT OF
X=565462.4580, Y=923158.7520.
(BRASS CAP IN HANDHOLE AT INTERSECTION OF LITCHFIELD ROAD AND GLENDALE AVENUE) USING A COMBINATION SCALE
FACTOR OF 1.0001261022.
VERTICAL DATUM - NAVD 1988.
2. CONTRACTOR SHALL RETAIN A LICENSED SURVEYOR TO SURVEY PROJECT IMPROVEMENTS. IF BENCHMARKS SHOWN ARE IN
AREAS THAT REQUIRE DEMOLITION, OTHER BENCHMARKS SHALL BE ESTABLISHED BEFORE DEMOLITION AND CONSTRUCTION
WORK BEGINS. CONTRACTOR SHALL SUPPLY CERTIFIED, CONTROL POINT DATA TO CONTRACTING OFFICER'S
REPRESENTATIVE AFTER COMPLETION OF CONSTRUCTION.
3. THE GEOTECHNICAL INVESTIGATION WAS PERFORMED BY KLEINFELDER FROM NOVEMBER 2010 TO MARCH 2011. THE
RESULTS OF THE INVESTIGATION ARE CONTAINED IN THE GEOTECHNICAL EXPLORATION REPORT AND ADDENDA.
4. BM ELEV. = 1078.31 BRASS CAP IN HANDHOLE LOCATED AT THE NORTHEAST CORNER OF SECTION 9, TOWNSHIP 2 NORTH, RANG 1 WEST, IN THE INTERSECTION OF LITCHFIELD ROAD AND GLENDALE AVENUE, MARICOPA COUNTY DATUM, NAVD 88. A
PORTION OF SECTION 4 AND A PORTION OF THE NORTH HALF OF SECTION 9, TOWNSHIP 2 NORTH, RANGE 1 WEST OF THE GILA
AND SALT RIVER BASE AND MERIDIAN, MARICOPA COUNTY, ARIZONA.
5. THERE ARE NO EASEMENTS ON SUBJECT PROPERTY PER CONDITION OF TITLE REPORT BY CHICAGO TITLE INSURANCE
COMPANY WITH AN EFFECTIVE DATE OF OCTOBER 12, 2010, ORDER NO. CT1021936.
6. BASIC UTILITIES (WATER, SEWER, STORM DRAIN, ELECTRIC AND GAS) ARE LUKE AFB OWNED AND SELF PROVIDED. QWEST
COMMUNICATIONS AND COX CABLE IS WITHIN THE PROJECT.
MATCHLINE -- SEE SHEET C-011 FOR CONTINUATION
B-1
B-2
B-3
B-5
B-6
BUILDING 470
EXISTING CONDITIONS NOTES:
1. THE LOCATIONS OF STRUCTURES AND UNDERGROUND UTILITIES AS INDICATED HAVE BEEN OBTAINED FROM EXISTING RECORDS
AND FIELD SURVEYS. UNDERGROUND STRUCTURES AND UTILITIES MAY BE PRESENT WHICH ARE NOT DOCUMENTED OR LOCATED.
2. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FIELD-VERIFY EXISTING STRUCTURES, UTILITIES, SERVICE CONNECTIONS, AND SURVEY INFORMATION, AND TO TAKE NECESSARY PRECAUTIONS DURING DEMOLITION AND CONSTRUCTION. ANY
DISCREPANCIES IN THE DRAWINGS SHALL BE IMMEDIATELY REPORTED TO THE CONTRACTING OFFICER'S REPRESENTATIVE
BEFORE ANY FURTHER WORK COMMENCES. CONTRACTOR SHALL CONTACT THE CONTRACTING OFFICER'S REPRESENTATIVE AND
ALL ASSOCIATED UTILITY COMPANIES AND AGENCIES TO IDENTIFY THE LOCATION OF UTILITIES. THERE IS NO GUARANTEE, EITHER
EXPRESSED OR IMPLIED, THAT THE LOCATIONS, SIZE AND TYPE OF MATERIAL OF EXISTING UNDERGROUND UTILITIES INDICATED
ARE REPRESENTATIVE OF THOSE TO BE ENCOUNTERED DURING CONSTRUCTION.
3. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ITEMS NOT TO BE DAMAGED DURING DEMOLITION AND CONSTRUCTION.
THE CONTRACTOR SHALL REPAIR OR REPLACE DAMAGED OR DISTURBED ITEMS TO THE SATISFACTION OF THE CONTRACTING
OFFICER'S REPRESENTATIVE.
5 23
C-012
I S
T I N
G
C
O N
D I T
I O
A
N
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
O
F
B-7
BUILDING 462
BUILDING 431
N 923600 t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
SITE DEMOLITION PLAN 1 OF 2
ASPHALT DEMOLITION
CONCRETE DEMOLITION
MISCELLANEOUS DEMOLITION
BUILDING DEMOLITION
LEGEND
GENERAL DEMOLITION NOTES:
1. ALL DEMOLITION, WASTE, DEBRIS, AND UNSATISFACTORY MATERIALS SHALL BE DISPOSED OF OFF BASE.
2. LOCATIONS NOTED FOR DEBRIS REMOVAL MAY CONTAIN ANY OF THE FOLLOWING MATERIALS: AGGREGATE, CONCRETE, ASPHALT, MASONRY, FOUNDATIONS, REBAR, FENCE MATERIAL, PIPING, AND MISCELLANEOUS STRUCTURES. LARGE PIECES OF
MATERIAL MAY NEED TO BE CRUSHED AND/OR BROKEN UP FURTHER IN ORDER TO BE HAULED AWAY TO THE WASTE DISPOSAL
SITE.
3. CONTRACTOR SHALL COORDINATE LIMITS OF SAWCUT AND PAVEMENT REMOVAL WITH PROPOSED PAVEMENT LAYOUT AND
JOINTING PLAN.
4. PAVEMENT DESIGNATED FOR SAWCUT SHALL BE SAWCUT FULL DEPTH.
5. EXISTING PAVEMENT EDGES SHALL BE SAWCUT IN LOCATIONS SHOWN TO PROVIDE CLEAN EDGE FOR CONSTRUCTION OF
PROPOSED PAVEMENT.
6. PAVEMENT REMOVAL LIMITS SHALL BE TO THE NEAREST EXISTING PAVEMENT JOINT TO THE GREATEST EXTENT POSSIBLE TO
PREVENT PARTIAL PANEL REMOVAL. PAVEMENT REMOVAL SHALL INCLUDE REMOVAL OF PAVEMENT AND ANY SUBBASE MATERIAL
PRESENT. EXISTING PAVEMENT IS APPROXIMATELY 3 INCHES ASPHALT OVER APPROXIMATELY 2 INCHES AGGREGATE BASE.
7. ANY DAMAGE TO PAVEMENT AREAS DESIGNATED TO REMAIN SHALL BE REPAIRED OR REMOVED AND REPLACED AT NO
ADDITIONAL COST TO CONTRACTING OFFICER'S REPRESENTATIVE.
8. CONTRACTOR SHALL PRESERVE EXISTING TREES AND VEGETATION WHENEVER PRACTICABLE. CONTRACTOR SHALL TAKE
NECESSARY PRECAUTIONS TO PROTECT ROOT SYSTEMS OF SHRUBS, PLANTS AND TREES ALONG THE AREA OF EXCAVATION.
9. EXISTING VEGETATION AND FACILITIES WHICH ARE NOT INDICATED TO BE REMOVED SHALL BE PROTECTED FROM DEMOLITION OR
OTHER CONSTRUCTION ACTIVITIES.
10. ALL EXISTING TURF AREAS WITHIN PROJECT LIMITS SHALL BE CLEARED AND GRUBBED.
11. ANY SIGNAGE NOT USED FOR PROPOSED CONSTRUCTION SHALL BE TURNED OVER TO THE CONTRACTING OFFICER'S
REPRESENTATIVE AS GOVERNMENT PROPERTY.
SAWCUT
DEMOLITION BY OTHERS
MISCELLANEOUS STRUCTURE AND
VEGETATION REMOVAL AND/OR RELOCATION
MATCHLINE -- SEE SHEET C-022 FOR CONTINUATION
PAINT REMOVAL
KEYED DEMOLITION NOTES:
SEE SHEET L-100 FOR PLANT SALVAGE PLAN.
6 23
C-021
T
E
D
E M
O L
I T
I O
N
P
L A
N
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
O
N 923400
N 923427.07
E 563095.11
N 923194.78
E 563104.02
N 923174.34
E 563198.57
N 923478.66
E 563091.18
N 923487.37
E 563323.72
N 923457.24
E 563324.73
N 923178.56
E 563315.84
N 923165.30
E 563316.15
N 923163.87
E 563254.07
N 923151.27
E 563202.94
N 923147.43
E 563103.95
N 923189.75
E 563102.31
SAWCUT
(272.59± LF)
N 923173.71
E 563139.29
N 923173.92
E 563144.29 t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
SITE DEMOLITION PLAN 2 OF 2
ASPHALT DEMOLITION
CONCRETE DEMOLITION
MISCELLANEOUS DEMOLITION
BUILDING DEMOLITION
LEGEND
GENERAL DEMOLITION NOTES:
1. ALL DEMOLITION, WASTE, DEBRIS, AND UNSATISFACTORY MATERIALS SHALL BE DISPOSED OF OFF BASE.
2. LOCATIONS NOTED FOR DEBRIS REMOVAL MAY CONTAIN ANY OF THE FOLLOWING MATERIALS: AGGREGATE, CONCRETE, ASPHALT, MASONRY, FOUNDATIONS, REBAR, FENCE MATERIAL, PIPING, AND MISCELLANEOUS STRUCTURES. LARGE PIECES
OF MATERIAL MAY NEED TO BE CRUSHED AND/OR BROKEN UP FURTHER IN ORDER TO BE HAULED AWAY TO THE WASTE
DISPOSAL SITE.
3. CONTRACTOR SHALL COORDINATE LIMITS OF SAWCUT AND PAVEMENT REMOVAL WITH PROPOSED PAVEMENT LAYOUT AND
JOINTING PLAN.
4. PAVEMENT DESIGNATED FOR SAWCUT SHALL BE SAWCUT FULL DEPTH.
5. EXISTING PAVEMENT EDGES SHALL BE SAWCUT IN LOCATIONS SHOWN TO PROVIDE CLEAN EDGE FOR CONSTRUCTION OF
PROPOSED PAVEMENT.
6. PAVEMENT REMOVAL LIMITS SHALL BE TO THE NEAREST EXISTING PAVEMENT JOINT TO THE GREATEST EXTENT POSSIBLE TO
PREVENT PARTIAL PANEL REMOVAL. PAVEMENT REMOVAL SHALL INCLUDE REMOVAL OF PAVEMENT AND ANY SUBBASE
MATERIAL PRESENT. EXISTING PAVEMENT IS APPROXIMATELY 3 INCHES ASPHALT OVER APPROXIMATELY 2 INCHES
AGGREGATE BASE.
7. ANY DAMAGE TO PAVEMENT AREAS DESIGNATED TO REMAIN SHALL BE REPAIRED OR REMOVED AND REPLACED AT NO
ADDITIONAL COST TO CONTRACTING OFFICER'S REPRESENTATIVE.
8. CONTRACTOR SHALL PRESERVE EXISTING TREES AND VEGETATION WHENEVER PRACTICABLE. CONTRACTOR SHALL TAKE
NECESSARY PRECAUTIONS TO PROTECT ROOT SYSTEMS OF SHRUBS, PLANTS AND TREES ALONG THE AREA OF EXCAVATION.
9. EXISTING VEGETATION AND FACILITIES WHICH ARE NOT INDICATED TO BE REMOVED SHALL BE PROTECTED FROM DEMOLITION
OR OTHER CONSTRUCTION ACTIVITIES.
10. ALL EXISTING TURF AREAS WITHIN PROJECT LIMITS SHALL BE CLEARED AND GRUBBED.
11. ANY SIGNAGE NOT USED FOR PROPOSED CONSTRUCTION SHALL BE TURNED OVER TO THE CONTRACTING OFFICER'S
REPRESENTATIVE AS GOVERNMENT PROPERTY.
SAWCUT
DEMOLITION BY OTHERS
SAWCUT
(30.15± LF)
REMOVE ASPHALT
PAVEMENT AND CURB AND
GUTTER (10904.50± SF)
BUILDING 475 TO
BE DEMOLISHED
BY OTHERS
BUILDING 470 TO
BE DEMOLISHED
BY OTHERS
SAWCUT
(51.71± LF)
CURB AND GUTTER
TO REMAIN
REMOVE CONCRETE
SIDEWALK (4341.48± LF)
SAWCUT
(117.35± LF)
MISCELLANEOUS STRUCTURE AND
VEGETATION REMOVAL AND/OR RELOCATION
MATCHLINE -- SEE SHEET C-021 FOR CONTINUATION
REMOVE CONCRETE
SIDEWALK (461.74± SF)
REMOVE CURB
AND GUTTER
(182.21± LF)
EXISTING TREES
SHALL REMAIN
(TYP 5)
KEYED DEMOLITION NOTES:
SEE SHEET L-100 FOR PLANT SALVAGE PLAN.
BASEMENT PIT BENEATH BUILDING 470 WILL BE EXPOSED FOLLOWING DEMOLITION OF BUILDING 470 BY OTHERS AND WILL
REQUIRE BACKFILL
REMOVE AND/OR SALVAGE
VEGETATION (TYP)
REMOVE AND
SALVAGE SIGN
REMOVE
STRUCTURE
REMOVE AND
SALVAGE SIGN (TYP)
REMOVE COOLER
REMOVE
STRUCTURE
REMOVE CANOPY
SALVAGE HIGH MAST
AIRFIELD LIGHT FOR
RELOCATION
REMOVE TRASH ENCLOSURE
TRASH BINS SHALL REMAIN
PROPERTY OF THE GOVERNMENT
7 23
C-022
T
E
D
E M
O L
I T
I O
N
P
L A
N
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
O
F
SAWCUT
(120.00± LF)
BUILDING
BUILDING 462
N 923400
N 923600
N 923200
N 923400
N 923600
N 923256.79
E 563072.14
N 923348.94
E 563345.50
N 923422.54
E 563359.73
N 923484.32
E 563200.33
EXISTING STORM
STRUCTURE SHALL REMAIN
N 923267.35
E 563366.97
N 923283.87
E 563347.84
CAP ELECTRICAL LINE FOR
NEW EXTENSION
N 923455.88
E 563311.37
REMOVE EXISTING
ELECTRICAL LINE
(136.10± LF)
t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
UTILITY DEMOLITION PLAN
UTILITY DEMOLITION
LEGEND
UTILITY DEMOLITION NOTES:
1. CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE
PRIOR TO REMOVAL OF EXISTING UTILITIES IN SERVICE. RELOCATED UTILITIES SHALL BE
CONSTRUCTED BEFORE REMOVAL OF EXISTING UTILITIES TO ENSURE UNINTERRUPTED
SERVICE TO THE FACILITIES SERVED BY THE UTILITY. ALL RELOCATIONS SHALL BE
COORDINATED WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.
2. IN AREAS OF UTILITY REMOVAL OF ABANDONED LINES, THE PORTION OF EXISTING
ABANDONED LINES TO REMAIN SHALL BE CAPPED OR PLUGGED AT REMOVAL INTERFACE.
UTILITY CAPPING METHODS SHALL BE IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS FOR SPECIFIC PIPE MATERIAL IN SERVICE. ALL CAPPING SHALL BE
INSPECTED AND APPROVED BY THE CONTRACTING OFFICER'S REPRESENTATIVE.
DEMOLITION OR REMOVAL
KEYED DEMOLITION NOTES
UTILITY HAS BEEN ABANDONED IN PLACE BY OTHERS AND
SHALL BE REMOVED.
REMOVE EXISTING
GAS LINE (126.50± LF)
REMOVE EXISTING
WATER LINE (93.86± LF)
REMOVE EXISTING
WATER LINE (50.80± LF)
REMOVE EXISTING
STORM LINE (294.88± LF)
REMOVE EXISTING
WATER LINE (93.91± LF)
REMOVE EXISTING FIBER
OPTIC LINE (251.00± LF)
UTILITY IS ACTIVE AND REQUIRES COORDINATION FOR
SHUTDOWN AND / OR RELOCATION.
COORDINATE WITH BASE CIVIL ENGINEERING PRIOR TO
REMOVAL OF EXISTING UTILITY POLES.
8 23
C-031
U
I L
I T
Y
D
E M
O L
I T
I O
N
P
L A
N
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
REMOVE EXISTING
UTILITY POLE
REMOVE EXISTING
UTILITY POLE
REMOVE
STRUCTURE
REMOVE EXISTING
UTILITY POLE
REMOVE EXISTING
PARKING LIGHT
t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
GENERAL BORING LOG NOTES:
1. THE SUBSURFACE CONDITIONS ARE OBTAINED FROM WIDELY
SPACED EXPLORATIONS. INFORMATION ON ACTUAL
SUBSURFACE CONDITIONS EXISTS ONLY AT LOCATIONS OF
EXPLORATIONS. CONDITIONS BETWEEN EXPLORATIONS MAY
VARY FROM THOSE DEPICTED.
2. ATTEMPTS WERE MADE TO MEASURE GROUNDWATER IN THE
SUBSURFACE EXPLORATIONS. FLUCTUATIONS IN WATER
LEVELS MAY OCCUR OVER MORE PROLONGED PERIODS OF
READINGS AND CAN BE INFLUENCED BY VARIOUS OUTSIDE
FACTORS. SEASONAL VARIATIONS IN RAINFALL, CHANGES TO
ON-SITE CONDITIONS, AND CHANGES TO OFF-SITE
CONDITIONS CAN AFFECT GROUNDWATER LEVELS. WATER
LEVELS OBSERVED AND RECORDED REFLECT ONLY THOSE
CONDITIONS THAT EXISTED AT THE TIME OF THE
INVESTIGATION.
3. THIS SHEET SHOULD BE READ WITH PROJECT GEOTECHNICAL
REPORT.
FOR
REFERENCE
ONLY
9 23
C-041
R I N
G
L
O G
S
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
O t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
GENERAL BORING LOG NOTES:
1. THE SUBSURFACE CONDITIONS ARE OBTAINED FROM WIDELY
SPACED EXPLORATIONS. INFORMATION ON ACTUAL
SUBSURFACE CONDITIONS EXISTS ONLY AT LOCATIONS OF
EXPLORATIONS. CONDITIONS BETWEEN EXPLORATIONS MAY
VARY FROM THOSE DEPICTED.
2. ATTEMPTS WERE MADE TO MEASURE GROUNDWATER IN THE
SUBSURFACE EXPLORATIONS. FLUCTUATIONS IN WATER
LEVELS MAY OCCUR OVER MORE PROLONGED PERIODS OF
READINGS AND CAN BE INFLUENCED BY VARIOUS OUTSIDE
FACTORS. SEASONAL VARIATIONS IN RAINFALL, CHANGES TO
ON-SITE CONDITIONS, AND CHANGES TO OFF-SITE
CONDITIONS CAN AFFECT GROUNDWATER LEVELS. WATER
LEVELS OBSERVED AND RECORDED REFLECT ONLY THOSE
CONDITIONS THAT EXISTED AT THE TIME OF THE
INVESTIGATION.
3. THIS SHEET SHOULD BE READ WITH PROJECT GEOTECHNICAL
REPORT.
FOR
REFERENCE
ONLY
10 23
C-042
R I N
G
L
O G
S
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
O
W MUSTANG ST.
BUILDING
BUILDING
BUILDING
BUILDING
BUILDING
BUILDING
BUILDING
N 923600
N 923400
N 923200
N 923000
N 922800
N 922600
N 922600
N 923000
N 923200
B-1
B-2
B-3
B-5
B-6
B-4
B-7
B-10
B-11
B-1
B-2
B-3
B-4
B-5
B-6
B-7 t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
OVERALL JSF COMPLEX SITE PLAN
11 23
C-100
E R
A L
L
J S
F
C
O M
P L
T
E
P
L A
N
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
33' AT/FP
A
T F
P
SQUADRON
OPERATIONS
FACILITY
A
T F
P
F
P
33' AT/FP
A
T F
P
A
T F
P
A
T F
P
F
P
A
T F
P
82' AT/FP
82' AT/FP
UTILITY
BUILDING
F-35 ACADEMIC
TRAINING CENTER
LEGEND
SCOPE OF WORK TO BE
COMPLETED BY OTHERS
A
T F
P
A
T F
P
A
T F
P
A
T F
P
LEED PROJECT BOUNDARY
LEED PROJECT BOUNDARY
LEED BOUNDARY
LEED
BOUNDARY
BUILDING 462
BUILDING 431
N 923600
F I G
H T
U
N T
E
N U
E t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
SITE LAYOUT PLAN - 1 OF 2
12 23
C-101
T
E
L
A Y
O U
T
P
L A
N
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
O
F
LEGEND
ASPHALT PAVEMENT
C-501
MATCHLINE -- SEE SHEET C-102 FOR CONTINUATION
SIDEWALK PAVERS
C-501
CONCRETE PAVEMENT
N 923410.16
E 563231.58
N 923175.60
E 563144.22
MATCH EXISTING
CURB
N 923173.92
E 563144.29
MATCH EXISTING
CURB
N 923180.64
E 563317.65
N 923271.91
E 563325.68
MATCH EXISTING CURB
N 923427.07
E 563095.11
CURB TRANSITION
N 923178.62
E 563263.40
RELOCATED HIGH MAST
AIRFIELD LIGHT
N 923178.29
E 563129.09
CONCRETE HEADER
ALONG PAVED EDGE
OF BUILDING
C-501
CURB TRANSITION
N 923177.26
E 563228.06
C-501
N 923400
N 923472.50
E 563091.43 t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
SITE LAYOUT PLAN - 2 OF 2
13 23
C-102
T
E
L
A Y
O U
T
P
L A
N
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
O
F
26.33'
88.91'
A
T F
P
A
T F
P
A
T F
P
A
T F
P
82' AT/FP
33' AT/FP
82' AT/FP
LEGEND
SQUADRON OPERATIONS
FACILITY
ARCHITECTURAL
SCREEN WALL
6.00'
GENERAL SITE NOTES:
1. BUILDING COORDINATES ARE POINTED TO OR MEASURED AT THE OUTSIDE FACE OF BUILDING
FOUNDATION. CONTRACTOR SHALL COORDINATE BEARINGS OF BUILDING WITH STRUCTURAL
DRAWINGS.
2. CONTRACTOR SHALL COORDINATE BUILDING ENTRANCES, EGRESSES, WALKWAYS, AND
DOORWAY LOCATIONS WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS.
3. SEE STRUCTURAL SHEET S-002 FOR SITE EQUIPMENT PAD DETAILS.
PROPOSED BUILDING
ANTI-TERRORISM / FORCE
PROTECTION STANDOFF
SIDEWALK PAVERS
C-501
82' AT/FP
REMOVABLE BOLLARDS
SPACED 3.00' ON
CENTER CENTERED ON
ROAD (TYP 6)
2.00'
6.00' 6.00'
A
T F
P
MATCHLINE -- SEE SHEET C-101 FOR CONTINUATION
GRADED CRUSHED
AGGREGATE SURFACE
COURSE
38.74'
6.00'
38.55'
(TYP)
REMOVABLE BOLLARDS
SPACED 3.00' ON CENTER
CENTERED ON ROAD
(TYP 7)
CURB AND
GUTTER
(TYP)
BICYCLE
RACK
C-501
C-502
C-502
C-501
C-502
MOUNTABLE
CURB
C-501
C-501
81.75'
KEYED SITE NOTES:
SEE ARCHITECTURAL DRAWINGS FOR SCREEN WALL AND GATE DETAILS.
SEE ELECTRICAL AND STRUCTURAL DRAWINGS FOR DETAILS ON HIGH MAST AIRFIELD LIGHT
RELOCATION.
15.00'
12.63'
C-501
C-502
C-502
BOLLARD
C-502
BOLLARD
(TYP 2)
C-502
W MUSTANG ST.
BUILDING
BUILDING
BUILDING
BUILDING
BUILDING
BUILDING
.0
1075.0
X
X
X
XXX
X X
X
N 923600
N 923400
N 923200
N 923000
N 922800
N 922600
N 922600
N 923000
N 923200
XXX
XXX
XXX
X X
X
X X
X
XXX
XXX
XXX
X
X
X
X X
X
XXX
t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
F-35 ACADEMIC
TRAINING CENTER
EROSION AND SEDIMENT
CONTROL PLAN
SQUADRON
OPERATIONS
FACILITY
A
T F
P
14 23
C-200
O S
I O
N
A
D
I M
E N
T
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
C O
N T
R O
L
P
L A
N
UTILITY
BUILDING
W
E
H
A
N
T
BUILDING
EROSION AND SEDIMENT CONTROL NOTES
BEST MANAGEMENT PRACTICES
1. CONSTRUCTION ACTIVITY POLLUTION PREVENTION IS REQUIRED FOR THIS
PROJECT. PREVENTION OF POLLUTION RESULTING FROM CONSTRUCTION
ACTIVITIES SHALL BE ACCOMPLISHED BY CONTROLLING SOIL EROSION,
WATERWAY SEDIMENTATION, AND AIRBORNE DUST GENERATION. CONTRACTOR
SHALL ENSURE THAT NO SEDIMENT RESULTING FROM CONSTRUCTION ACTIVITIES
INFRINGES ONTO ADJACENT PROPERTIES. CONTRACTOR SHALL COORDINATE
EROSION AND SEDIMENT CONTROL WITH OTHER CONSTRUCTION ENTITIES
PERFORMING WORK ON ADJACENT PROPERTIES.
2. SOIL EROSION AND SEDIMENT CONTROLS ARE MEASURES USED TO REDUCE THE
AMOUNT OF SOIL PARTICLES THAT ARE CARRIED OFF AN AREA AND DEPOSITED
INTO A DRAINAGE COLLECTION SYSTEM OR INTO A BODY OF WATER. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT EROSION AND
SEDIMENTATION ARE CONTROLLED TO THE EXTENT PRACTICABLE. ALL
APPLICABLE SOIL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE
IMPLEMENTED AND MAINTAINED THROUGHOUT THE DURATION OF
CONSTRUCTION ACTIVITIES. PRIOR TO INITIATING CONSTRUCTION IN AN AREA,
ALL TEMPORARY EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE IN
PLACE. UPON PROJECT COMPLETION ALL TEMPORARY SOIL EROSION AND
SEDIMENT CONTROL MEASURES SHALL BE REMOVED.
3. TEMPORARY EROSION CONTROL SHALL BE THE CONTRACTOR'S RESPONSIBILITY,
WHO SHALL UTILIZE APPROPRIATE BEST MANAGEMENT PRACTICES (BMPS).
THOSE BMPS SHALL CONSIST OF SILT FENCE, WATTLES OR OTHER MEANS TO
CONTROL EROSION AS NEEDED. THE CONTRACTOR SHALL PROVIDE AND FOLLOW
THE EROSION CONTROL AND SWPPP PLANS AS NEEDED.
4. CONTRACTOR SHALL PLACE SILT FENCE AS SHOWN PRIOR TO BEGINNING WORK.
THE DEVICES SHALL BE PLACED DOWN-SLOPE OF DISTURBED AREAS WHERE
SHEET EROSION WOULD OCCUR. SILT FENCE SHALL BE CLEANED AND REPAIRED
WHEN SEDIMENT BUILDUP REACHES ONE-THIRD OF SILT FENCE HEIGHT. AFTER
SIGNIFICANT RUNOFF EVENTS, THE CONTRACTOR SHALL INSPECT ALL EROSION
CONTROL STRUCTURES FOR SILT BUILD-UP THAT INTERFERES WITH THE
PERFORMANCE OF THE EROSION CONTROL STRUCTURE AND REPAIR OR
REPLACE THOSE STRUCTURES, AS NECESSARY.
5. ALL STORM DRAIN INLETS SHALL BE PROTECTED BY APPROPRIATE BMPS DURING
CONSTRUCTION, UNTIL ALL SOURCES WITH POTENTIAL FOR DISCHARGE TO THE
INLETS HAVE BEEN STABILIZED.
6. ALL EXISTING DRAIN INLETS SHALL HAVE SILT FENCE PROTECTION INSTALLED IN
ACCORDANCE WITH DETAIL 1 ON SHEET C-507. EROSION PROTECTION MAY BE
REMOVED WHEN VEGETATION IS ESTABLISHED.
7. STRAW-BALE CHECK DAMS MAY BE PLACED IN DRAINAGE SWALES TO LIMIT THE
AMOUNT OF SEDIMENT THAT TRAVELS DOWNSTREAM. STRAW BALES MAY BE
USED AS INLET PROTECTION FOR STORM SEWER CATCH BASIN. THESE DEVICES
MUST BE MAINTAINED AND THE SEDIMENT REMOVED BEHIND THE DEVICE ON A
REGULAR BASIS TO REMAIN EFFECTIVE.
8. CONTRACTOR SHALL INSTALL A STABILIZED CONSTRUCTION ENTRANCE AT
LOCATIONS WHERE CONSTRUCTION TRAFFIC SHALL ENTER THE PROJECT SITE
FROM ROADWAYS AND PAVEMENTS. SEE DETAIL 5 ON SHEET C-507.
9. SEE SHEET C-506 FOR ADDITIONAL DETAILS ON EROSION AND SEDIMENT
CONTROL.
CONSTRUCTION ACCESS
THE SITE SHALL HAVE ROADS AND ACCESS DRIVES OF SUFFICIENT WIDTH AND
LENGTH TO PREVENT SEDIMENT FROM TRACKING ONTO PUBLIC ROADWAYS.
SEDIMENT SHALL BE REMOVED IMMEDIATELY FROM THE ROAD BY SHOVELING OR
SWEEPING WHEN SEDIMENT IS TRANSPORTED ONTO A PUBLIC ROAD SURFACE OR
OTHER PAVED AREA BY EQUIPMENT OR VEHICLES EXITING THE CONSTRUCTION SITE.
BULK CLEARING OF ACCUMULATED SEDIMENT SHALL BE TRANSPORTED TO A
CONTROLLED SEDIMENT DISPOSAL AREA OR THE POINT OF LIKELY ORIGIN BEFORE
THE END OF EACH WORK DAY. ROAD WASHING SHALL BE ALLOWED ONLY AFTER THE
SEDIMENT IS REMOVED IN THE ABOVE MANNER.
FINAL GRADING AND CLEAN UP
AFTER COMPLETION OF FINAL GRADING, THE DISTURBED AREAS SHALL BE
REVEGETATED. ALL TEMPORARY EROSION AND SEDIMENT CONTROL DEVICES SHALL
BE REMOVED UPON PROJECT COMPLETION. TRAPPED SEDIMENT AND OTHER
DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY
CONTROL MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER
EROSION AND SEDIMENTATION.
PETROLEUM PRODUCTS
ALL ON-SITE VEHICLES SHALL BE MONITORED FOR PETROLEUM LEAKS AND SHALL
RECEIVE PROPER PREVENTATIVE MAINTENANCE TO REDUCE THE CHANCE OF
LEAKAGE. PETROLEUM PRODUCTS SHALL BE STORED IN TIGHTLY-SEALED
CONTAINERS THAT ARE CLEARLY LABELED. ALL SPILLS SHALL BE CLEANED UP
IMMEDIATELY AFTER DISCOVERY. WASTE OIL AND OTHER PETROLEUM PRODUCTS
SHALL NOT BE DISCHARGED ONTO THE GROUND OR INTO WATER BODIES.
PETROLEUM PRODUCTS USED ON-SITE SHALL BE APPLIED ACCORDING TO THE
MANUFACTURER RECOMMENDATIONS.
SILT FENCE
SILT FENCE
C-506
C-506
C-506
SILT FENCE
CATCH BASIN
PROTECTION
C-506
GRAVEL AND WIRE MESH
SEDIMENT FILTER
C-506
TEMPORARY
CONSTRUCTION
FENCE
C-502
TEMPORARY
CONSTRUCTION
FENCE
C-502
BUILDING
N 923400
N 923200
HH
HH
1074.5
1074.5
1074.5
1076.0
1074.84
TC 1075.35
BC 1074.85
1075.63
1075.26
1075.12
1075.95
1075.95
1076.91
1075.95
1076.91
1075.45
1076.91
1074.49
1074.59
M
A
T
C
H t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
SITE GRADING PLAN
15 23
C-201
T
E
G
R A
D I N
G
P
L A
N
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
SQUADRON
OPERATIONS FACILITY
FF=1076.95'
GENERAL GRADING NOTES:
1. PROPOSED ELEVATIONS INDICATED ARE FOR TOP OF FINAL GRADE, PAVEMENT, OR STRUCTURE UNLESS
INDICATED OTHERWISE.
2. ELEVATION DENOTED AS "MATCH" ARE INTENDED TO MEET EXISTING GRADE ELEVATIONS. CONTRACTOR
SHALL VERIFY ELEVATIONS AT TIE-INS AND MATCH POINTS PRIOR TO BEGINNING CONSTRUCTION.
3. EXTERIOR FINISH GRADES AT BUILDING ENTRANCES AND EGRESSES SHALL BE 0.5 INCHES BELOW BUILDING
FINISH FLOOR UNLESS INDICATED OTHERWISE.
4. EXTERIOR FINISH GRADES ADJACENT TO BUILDING SHALL BE 12.00 INCHES BELOW BUILDING FINISH FLOOR
UNLESS INDICATED OTHERWISE.
5. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION. ANY DRAINAGE
FEATURE OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING
CONDITIONS OR BETTER SUBJECT TO THE APPROVAL OF THE CONTRACTING OFFICER'S REPRESENTATIVE.
6. SURFACES AROUND FACILITY SHALL BE GRADED TO PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDINGS
AND PAVEMENTS.
7. THE CONTRACTOR SHALL REMOVE STANDING WATER FROM THE PROJECT WORK LIMITS AS NECESSARY TO
PROTECT SUBGRADE, SUBBASE, AND/OR BASE COURSE OF NEW PAVEMENT, SURROUNDING
PAVEMENT-TO-REMAIN, OR OTHER COMPLETED WORKS.
8. SEE SHEETS C-200 AND C-506 FOR RECOMMENDED BEST PRACTICES FOR SEDIMENT AND EROSION
CONTROL.
9. TOP ELEVATION OF ALL UTILITY STRUCTURES TO REMAIN SHALL BE ADJUSTED ACCORDINGLY TO FINISH
GRADE ELEVATION.
10. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE RE-VEGETATED IN ACCORDANCE WITH THE
SPECIFICATIONS.
11. SEE DETAIL 2 ON SHEET C-505 FOR TYPICAL ROOF DRAIN DOWNSPOUT CONNECTION.
CONNECT NEW 24" STORM
DRAIN TO EXISTING
STORM STRUCTURE
N 923195.11
E 563076.77
RIM 1073.36
INV IN (E) 1068.06
INV IN (S) 1067.86
INV OUT (N) 1067.83
CONNECT TO
EXISTING 15" SD
CAPPED BY OTHERS
N 923258.96
E 563343.28
INV 1069.86
CONNECT TO
EXISTING 15" SD
CAPPED BY OTHERS
N 923332.42
E 563319.84
INV 1070.10
12" SD (HDPE)
15" SD (HDPE)
15" SD (HDPE)
12" SD
(HDPE)
CONNECT NEW 24" SD
TO EXISTING STORM
STRUCTURE
N 923266.59
E 563366.76
INV 1070.02
24" SD (HDPE)
STORM MANHOLE
N 923167.55
E 563276.64
RIM 1074.90
INV IN (NE) 1068.23
INV OUT (W) 1068.06
24" SD
(HDPE)
24" SD (HDPE)
CATCH BASIN
N 923255.20
E 563254.21
RIM 1076.60
INV 1071.53
CLEANOUT
N 923295.16
E 563252.52
RIM 1076.08
INV 1071.73
C-504
CLEANOUT
N 923211.24
E 563256.07
RIM 1076.57
INV 1071.76
CLEANOUT
N 923173.96
E 563225.64
RIM 1075.09
INV 1072.02
STORM MANHOLE
N 923160.88
E 563118.46
RIM 1074.29
INV IN (E) 1068.30
INV OUT (N) 1068.13
C-504
STORM MANHOLE
N 923196.45
E 563117.69
RIM 1075.11
INV IN (S) 1068.10
INV OUT (W) 1067.93
C-504
CLEANOUT
N 923170.36
E 563140.44
RIM 1074.61
INV 1072.48
C-503
C-504
12" STORM
DRAIN (HDPE)
12" SD
(HDPE)
CLEANOUT
N 923329.06
E 563239.00
RIM 1076.18
INV 1071.62
CLEANOUT
N 923420.32
E 563235.15
RIM 1075.29
INV 1072.10
CLEANOUT
N 923416.14
E 563136.07
RIM 1075.73
INV 1072.64
C-503
CLEANOUT
N 923290.14
E 563135.38
RIM 1075.95
INV 1073.10
C-503
CLEANOUT
N 923324.88
E 563139.92
RIM 1075.49
INV 1073.20
C-503
C-503
C-503
C-503
C-503
C-503
C-503
12" SD
(HDPE)
12" SD
(HDPE)
C-504
MH
HH
HH
HH
HH
N 923200
N 923400
CONNECT TO EXISTING
10" W LINE
N 923247.29
E 563349.06
CONNECT TO EXISTING
10" W LINE
N 923240.90
E 563349.27
CONNECT TO EXISTING
2" G CAPPED BY OTHERS
N 923292.95
E 563319.52
CONNECT TO EXISTING
10" W LINE
N 923192.50
E 563350.88
CHILLED WATER
VALVE ASSEMBLY
N 923476.15
E 563293.58
TRANSFORMER
N 923182.51
E 563273.07
CONNECT CWS/CWR
TO EXISTING 4" FLANGE
CONNECTIONS
N 923479.99
E 563771.69
POST INDICATOR
VALVE
N 923240.78
E 563346.27
C-504
EXISTING
FH
EXISTING
FH
CHILLED WATER VALVE ASSEMBLY
N 923484.44
E 563295.71
90° CWS BEND
N 923476.49
E 563288.50
90° CWR BEND
N 923475.53
E 563289.55 t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
GENERAL UTILITY NOTES:
1. ALL PIPE SIZES ARE IN INCHES UNLESS INDICATED OTHERWISE.
2. CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL BUILDING CONNECTIONS WITH BUILDING
CONTRACTOR AND THE INFORMATION PROVIDED ON MECHANICAL AND ELECTRICAL DRAWINGS
FOR EACH FACILITY.
3. CONTRACTOR SHALL CONTACT THE CONTRACTING OFFICER'S REPRESENTATIVE AND ALL
ASSOCIATED UTILITY COMPANIES AND AGENCIES TO IDENTIFY THE LOCATION OF UTILITIES PRIOR
TO COMMENCEMENT OF WORK.
4. CONTRACTOR SHALL COORDINATE ALL REQUIRED UTILITY SHUTDOWNS FOR UTILITY
CONNECTIONS WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.
5. CONNECTION TO EXISTING UTILITY MAINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH ALL
REQUIREMENTS OF ASSOCIATED UTILITY COMPANIES AND AGENCIES.
6. CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND PAYING ALL UTILITY CONNECTION FEES
AND OBTAINING ALL PERMITS REQUIRED FOR THE UTILITY CONSTRUCTION AND CONNECTIONS.
THIS INCLUDES ALL FEES ASSOCIATED WITH CONNECTION CHARGES AND METERS.
7. SEE DETAIL 1 ON SHEET C-503 FOR TYPICAL PIPE TRENCH DETAIL.
8. THE MINIMUM DEPTH OF COVER FOR ALL UTILITY PIPING SHALL BE 36 INCHES UNLESS INDICATED
OTHERWISE.
9. THRUST BLOCKS OR JOINT RESTRAINTS ARE REQUIRED AT ALL TEES, BENDS, OR ELBOWS OF
PRESSURIZED PIPING IN ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS, AND
MANUFACTURER'S RECOMMENDATIONS. SEE DETAIL 2 ON SHEET C-503 FOR TYPICAL THRUST
BLOCK DETAIL.
10. WATER LINES SHALL BE INSTALLED A MINIMUM OF 3.00 FEET BEHIND THE EDGE OF PAVEMENT OR
FACE OF CURB UNLESS INDICATED OTHERWISE. SEE SPECIFICATIONS FOR ADDITIONAL
CLEARANCE REQUIREMENTS FOR WATER PIPING.
11. FIRE HYDRANTS SHALL BE INSTALLED A MINIMUM OF 3.00 FEET AND A MAXIMUM OF 6.00 FEET
FROM EDGE OF PAVEMENT OR FACE OF CURB AND A MINIMUM OF 1.00 FEET FROM EDGE OF
SIDEWALK UNLESS INDICATED OTHERWISE. A RADIUS OF 3.00 FEET AROUND HYDRANT SHALL BE
KEPT CLEAR FOR FIRE DEPARTMENT ACCESS. AREA BETWEEN CURB AND HYDRANTS SHALL BE
KEPT CLEAR OF OBSTRUCTIONS.
12. ALL UTILITY STRUCTURES ARE TO BE H-20 RATED UNLESS INDICATED OTHERWISE.
13. IF A MANHOLE IS LOCATED IN PAVEMENT AREAS, RIM ELEVATION SHALL BE FLUSH WITH FINAL
GRADE. IF A MANHOLE IS LOCATED OUTSIDE OF PAVEMENT AREAS, RIM ELEVATION SHALL BE
6.00" MINIMUM ABOVE ADJACENT FINISH GRADE
14. COVERS AND CASTINGS OF MANHOLES AND STRUCTURES SHALL BE STAMPED PER THE
APPROPRIATE UTILITY TYPE OR PER THE LOCAL STANDARDS.
15. COVERS AND CASTINGS SHALL BE TAMPER-PROOF FOR STRUCTURES LOCATED IN PEDESTRIAN
AREAS, EASEMENT AREAS, AND AREAS WITH SPECIAL SECURITY RESTRICTIONS.
16. SEE DETAIL 4 ON SHEET C-504 FOR TYPICAL SEWER ENCASEMENT DETAIL WHERE REQUIRED.
17. ALL UNDERGROUND UTILITIES ARE SUBJECT TO ACCEPTANCE TESTING AND INSPECTION
METHODS DETAILED IN THE SPECIFICATIONS AND AS REQUIRED BY ASSOCIATED UTILITY
COMPANIES.
18. ANY CHANGES TO PROPOSED UTILITY DESIGN SHALL BE APPROVED BY THE CONTRACTING
OFFICER'S REPRESENTATIVE.
SITE UTILITY PLAN
16 23
C-301
T
E
U
T I L
I T
Y
P
L A
N
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
CONNECT TO EXISTING SS
MANHOLE
N 923454.61
E 563379.35
SQADRON OPERATIONS
FACILITY
FF = 1076.95'
8" SS (PVC)
SSMH-1
FH-1
N 923192.26
E 563343.70
6" F (CI)
3" W (CI)
6" SS (PVC)
2" G (PE)
8" SS (PVC)
6" CWR (PVC)
6" CHS (PVC)
KEYED UTILITY NOTES:
4" CHILLED WATER SUPPLY AND 4" CHILLED WATER RETURN PIPING SHALL BE EXTENDED AND
CAPPED FOR FUTURE EXTENSION TO THE NORTH.
SEE SHEET C-311 FOR SANITARY SEWER PROFILE.
SEE ELECTRICAL DRAWINGS FRO DETAILS OF ELECTRICAL AND COMMUNICATIONS ROUTING AND
STRUCTURES.
VALVE
N 923192.40
E 563348.05
C-503
C-503
C-504
C-504
VALVE
N 923246.82
E 563337.82
C-504
SSMH-2
C-504
2" G
6" SS
4" CWS
4" CWR
3" W
6" F
COMM
ELEC
FIRE DEPARTMENT
CONNECTION
EXISTING 8" SS (VCP)
EXISTING 10" W (CI)
C-504
4" CWS (PVC)
4" CWR (PVC)
STORM DRAIN LINE
SANITARY SEWER LINE
DOMESTIC WATER LINE
UNDERGROUND
ELECTRICAL LINE
NATURAL GAS LINE
RD ROOF DRAIN
LEGEND
FIRE WATER LINE
SANITARY SEWER MANHOLE
CLEANOUT
COMMUNCATION
C-504
C-503
C-503
C-503
-0+100+00
3+00 3+34.66
EX-SSMH-1
N 923454.61
E 563379.35
SSMH-1
N 923451.90
E 563317.54
SSMH-2
N 923282.13
E 563324.71
6" SS (PVC)
6" SS (INV 1073.45)
SQUADRON OPERATIONS
FACILITY
8" SS (PVC)
8" SS (PVC)
HH
HH
HH
N 923400
1066.0
1068.0
1072.0
1076.0
1080.0
1066.0
1068.0
1072.0
1076.0
1080.0
-0+25 0+00
1+00
2+00
3+00
S S
S T
A
I N
V
S
S
W
I N
V
O
S
S
N
R
S S
S T
A
I N
V
S
S
S
I N
V
O
S
S
E
R
E X
S
S M
H
S T
A
I N
V
S
S
W
R
" S
S
.9
S
S
.0
4" CWR
4" CWS
EX. 24"
WATER
EX. 10"
WATER
EX. FIBER
OPTIC
EX. FIBER
OPTIC
EX. ELECTRIC
15" STORM DRAIN
FL=1070.18
3" GAS
LINE
EX. ELECTRIC
EX. FIBER OPTIC
12" STORM
DRAIN
FL=1073.45
I N
V
O
E
E t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
SANITARY SEWER PLAN VIEW 1
SANITARY SEWER PROFILE VIEW 1
HOR.
VER.
SANITARY UTILITY NOTES:
1. ALL SANITARY LINES ARE TO BE LAID AT A UNIFORM SLOPE FROM THE BUILDING CONNECTIONS TO
THE CONNECTING SEWER AND BETWEEN UTILITY STRUCTURES.
2. SEWER LINES SHALL BE INSTALLED A MINIMUM OF 10.00 FEET HORIZONTALLY FROM ADJACENT
WATER LINES UNLESS INDICATED OTHERWISE. SEE SPECIFICATIONS FOR ADDITIONAL
CLEARANCE REQUIREMENTS FOR SANITARY PIPING.
3. SEWER LINES SHALL BE INSTALLED BELOW WATER LINES WITH A MINIMUM VERTICAL SEPARATION
OF 24 INCHES UNLESS INDICATED OTHERWISE.
4. IF MANHOLES ARE INDICATED ON SANITARY LINES, A 2.00 INCH DROP IN ELEVATION BETWEEN THE
INCOMING AND OUTGOING SEWER SHALL BE PROVIDED IN EACH MANHOLE UNLESS INDICATED
OTHERWISE. INVERT FLOW CHANNELS SHALL BE CONSTRUCTED TO PROVIDE SMOOTH AND
UNIFORM SLOPE WITH GRADUAL TRANSITION SECTIONS.
17 23
C-311
N I T
A R
Y
S
E W
E R
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
P L
O
F I L
E
STORM DRAIN LINE
SANITARY SEWER LINE
DOMESTIC WATER LINE
UNDERGROUND
ELECTRICAL LINE
NATURAL GAS LINE
RD ROOF DRAIN
LEGEND
FIRE WATER LINE
SANITARY SEWER MANHOLE
CLEANOUT
COMMUNICATION
PROPOSED GRADE
EXISTING GRADE
t h
F
I G
H T
N
G
L U
L E
N D
A L E
A
R I Z
O N
A
F
S
Q U
A D
R O
N
O
P E
R A
T I O
C
I L I T
Y
S
Q
O
P S
U S
A C
E
T
A S
K
N
O
D E
S C
R I P
T I O
N D a t e
A p p r
M a r k
2 3 4 5
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
L O
S
A
N G
E L
E S
C
A L
I F
O R
N I A
SHEET NO.
OF
SEQUENCE NO.
1 2 3 4 5
A
B
C
DD
C
B
A
B U
R N
D
O N
N E
L L
K A
N S
T
Y
M
O
R
D
P
A R
K W
A Y
ISSUED FOR BID
18 23
V E
M E
T
A I L
S
K
R
O B
E R
T S
S
E
N G
E M
A N
N
J
I S
N E
R
L U
C d w g
N O
T
T
O
S
C A
SECTION
SECTION
C-101
24" COMPACTED SUBGRADE
SUBGRADE
6" GRADED CRUSHED AGGREGATE
BASE COURSE
PRIME COAT
3" ASPHALTIC CONCRETE
(2 EQUAL LIFTS) WITH TACK COAT
TYPICAL VEHICULAR ASPHALT PAVEMENT
SECTION
C-101
C-503
SECTION
C-102
2 SECTION
C-102
TYPICAL CONCRETE PAVER SIDEWALK
36" COMPACTED
SUBGRADE
6" GRADED CRUSHED
AGGREGATE SURFACE
COURSE
SECTION
C-102
GRADED CRUSHED AGGREGATE
SURFACE COURSE DETAIL
CONCRETE
HEADER
JOINTING SAND
3" INTERLOCKING PAVERS
90 DEGREE HERRINGBONE
PATTERN
1-1/4" BEDDING
SAND
(PRE-COMPACTED
THICKNESS)
8" GRADED CRUSHED
AGGREGATE BASE
COURSE
TYPICAL VEHICULAR CONCRETE PAVER
24" COMPACTED
SUBGRADE
GEOTEXTILE
NOTES:
1. THICKNESS OF ALL REPLACEMENT COURSES SHALL BE EQUAL TO EXISTING BUT
SHALL NOT BE LESS THAN INDICATED.
2. BASE COURSE SHALL BE ASPHALTIC CONCRETE BASE TO REPLACE ALL BASE
MATERIALS.
3. SAWCUTS THAT EXTEND OUTSIDE THE AREA OF REMOVAL AND REPLACEMENT
SHALL BE FILLED WITH AN EPOXY-BASED GROUT APPROVED BY CONTRACTING
OFFICER'S REPRESENTATIVE.
EXISTING
ASPHALTIC
CONCRETE
VARIES
ASPHALTIC CONCRETE
BASE (6" MIN)
12"
(TYP)
EXCAVATION LIMITS
6" COMPACTED
SUBGRADE
12"
(MIN)
ASPHALTIC
CONCRETE (2" MIN)
TACK COAT
SAW CUT (TYP)
ASPHALT PAVEMENT REMOVAL AND REPLACEMENT
CONCRETE HEADER
JOINTING SAND
3" INTERLOCKING PAVERS
90 DEGREE HERRINGBONE PATTERN
1-1/4" BEDDING SAND
(PRE-COMPACTED THICKNESS)
4" GRADED
CRUSHED
AGGREGATE
BASE COURSE
24" COMPACTED
SUBGRADE
GEOTEXTILE
CONCRETE
HEADER
CONCRETE HEADER
12"
SIDEWALK WIDTH
36"
TYPICAL
SIDEWALK
INTERSECTION
VARIES
V A
R I E
S
SEE SITE PLAN FOR WIDTH
9"
15"
#4 CONTINUOUS
#4 CONTINUOUS
TYPE A JOINT
6' MAX
M
A X
" RADIUS
" RADIUS
TYPE A
TRANSVERSE JOINT
PRE-FORMED
EXP. JOINT
MATERIAL
TYPE B
EXPANSION JOINT
PLAN
6" COMPACTED
SUBGRADE
4" CONCRETE
TYPE B JOINT @
24' CENTERS MAX
TYPICAL CONCRETE SIDEWALK
NOTES:
1. TYPE A JOINTS TO BE LOCATED TO MAINTAIN AN APPROXIMATE SQUARE
SLAB AS INDICATED ON PLANS.
2. TYPE B JOINTS TO BE LOCATED WHERE WALK ABUTS EXISTING SIDEWALK,
CONCRETE CURBS, DRIVES, STRUCTURES AND WHERE WALK CHANGES
DIRECTION.
3. CONCRETE PANELS SHALL HAVE LIGHT BROOM FINISH.
4. SIDEWALKS SHALL BE REINFORCED WITH 6" X 6" - W3 X W3 WELDED WIRE
FABRIC.
(TYP)
T
Y P
36"
TYPICAL
SIDEWALK
INTERSECTION
VARIES
V A
R I E
S
#4 STIRUP
@ 18" ON CENTER
DETAIL
C-101
C-102
24"
7" ROADWAY
WIDTH
6" 1"
12"
BROOM FINISH
V A
R I E
S
TYPE A VERTICAL CURB AND GUTTER
1/2" BATTER
OPTIONAL
PAVEMENT
24"
7" ROADWAY
WIDTH
5-1/8"1-7/8"
12"
BROOM FINISH
CURB TRANSITION TYPE 'E' TO TYPE 'A'
TYPE E MOUNTABLE CURB AND GUTTER
PAVEMENT
3/4" R
2" R1/2" R
C
U
A
N
S
I
T
I
O
N
TYPE 'A' VERTICAL
CURB AND GUTTER
DETAIL
C-102
9DETAIL
C-102
SEE NOTE 1
NOTES:
1. FOR INSTANCES WHERE CURB AND GUTTER IS
ADJACENT TO CONCRETE PAVEMENT, PROVIDE TIE
BAR #16 - 30" LONG @ 30" ON CENTER
2. WHEN THE ADJACENT PAVEMENT SECTION SLOPES
AWAY FROM THE GUTTER, THE SLOPE OF THE GUTTER
PAN SHALL MATCH PAVEMENT…
This is the start of the file's text. The full file is on GovTribe.