W912PL-10-R-0025 Vol 2.pdf
PDF 4 MB Posted
- Attached to
- FY 10 Personnel Recovery Center of Excellence, Davis Monthan Air Force Base, Pima County, Arizona
- Solicitation number
- W912PL-10-R-0025
About this file
Specification Volume 2
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Am9.pdf | ||
| Am8.pdf | ||
| Am7.pdf | ||
| Am6_W912PL-10-R-0025.pdf | ||
| Am5_W912PL-10-R-0025.pdf | ||
| 10R0025Am4.pdf | ||
| 10R0025Am3.pdf | ||
| 10R0025Am2.pdf | ||
| 10R0025Am1.pdf | ||
| W912PL-10-R-0025 Vol 3.pdf | ||
| W912PL-10-R-0025 Vol 1.pdf | ||
| HC-130J_RQS_SQUADRON_OPERATIONS.zip | ZIP file | |
| HC-130J_SIMULATOR_FACILITY.zip | ZIP file | |
| HC-130J_INFRASTRUCTURE.zip | ZIP file | |
| W912PL-10-R-0025 Vol 4.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in Acrobat 9 or Adobe Reader 9, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
SECTION 10 14 02
INTERIOR SIGNAGE
04/06
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF-45 (2003) Designation System for Aluminum Finishes
AA PK-1 (2008) Pink Sheets: Designations and Chemical Composition Limits for Aluminum Alloys in the Form of Castings and Ingot
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA 2604 (2005) Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels
AMERICAN WELDING SOCIETY (AWS)
AWS D1.2/D1.2M (2008) Structural Welding Code - Aluminum
ASTM INTERNATIONAL (ASTM)
ASTM B 209 (2007) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate
ASTM B 221 (2008) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM C 1036 (2006) Standard Specification for Flat Glass
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Detail Drawings; G
10 14 02 - 1
Drawings showing elevations of each type of sign, dimensions, details and methods of mounting or anchoring, shape and thickness of materials, and details of construction. A schedule showing the location, each sign type, and message shall be included.
SD-03 Product Data
Installation; G
Manufacturer's descriptive data, catalogs cuts, installation and cleaning instructions.
SD-04 Samples
Interior Signage; G
One sample of each of the following sign types showing typical quality, workmanship and color. The samples may be installed in the work, provided each sample is identified and location recorded.
a. Directional sign.
b. Standard Room sign.
c. Changeable message strip sign.
SD-10 Operation and Maintenance Data
Approved Manufacturer's Instructions Protection and Cleaning
Six copies of operating instructions outlining the step-by-step procedures required for system operation shall be provided. The instructions shall include simplified diagrams for the system as installed. Six copies of maintenance instructions listing routine procedures, repairs, and guides shall be provided. The instructions shall include the manufacturer's name, model number, service manual, parts list, and brief description of all equipment and their basic operating features. Each set shall be permanently bound and shall have a hard cover. The following identification shall be inscribed on the covers: the words "OPERATING AND MAINTENANCE INSTRUCTIONS", name and location of the facility, name of the Contractor, and contract number.
1.3 GENERAL
Interior signage shall be of the design, detail, sizes, types, and message content shown on the drawings/attachments/signage placement schedule (as applicable), shall conform to the requirements specified, and shall be provided at the locations indicated. Signs shall be complete with lettering, framing as detailed, and related components for a complete installation. Signage shall be obtained from a single manufacturer with edges and corners of finished letterforms and graphics true and clean.
Recyclable materials shall conform to EPA requirements in accordance with Section 01 62 35 RECYCLED / RECOVERED MATERIALS.
1.4 QUALIFICATIONS
Signs, plaques, and dimensional letters shall be the standard product of a
10 14 02 - 2 manufacturer regularly engaged in the manufacture of such products and shall essentially duplicate signs that have been in satisfactory use at least 2 years prior to bid opening.
1.5 DELIVERY AND STORAGE
Materials shall be packaged to prevent damage and deterioration during shipment, handling, storage and installation. Product shall be delivered to the jobsite in manufacturer's original packaging and stored in a clean, dry area in accordance with manufacturer's instructions.
1.6 EXTRA STOCK
The Contractor shall provide [_____] extra frames and extra stock of the following: [[_____] blank plates of each color and size for sign types [_____].] [[_____] pressure-sensitive letters in each color and size for sign type [_____].] [[_____] changeable message strips for sign type
PART 2 PRODUCTS
2.1 ROOM IDENTIFICATION/DIRECTIONAL SIGNAGE SYSTEM
2.1.1 Standard Room Signs
Signs shall consist of laminated thermosetting Type MP plastic (three-ply melamine plastic laminate with phenolic core) and shall conform to the following:
Units shall be frameless. Corners of signs shall be rounded to 3/8 inch radius.
2.1.2 Changeable Message Strip Signs
Changeable message strip signs shall be of same construction as standard room signs to include a clear sleeve that will accept a paper or plastic insert identifying changeable text. The insert shall be prepared typeset message photographically enlarged to size and mounted on paper card stock.
Furnish paper and software for creating text and symbols for IBM compatible computers for Owner production of paper inserts after project completion.
Sliding inserts or slide knobs that slide horizontally exposing different graphic information shall be provided as identified in the signage placement schedule and drawings
2.1.3 Type of Mounting For Signs
Extruded aluminum brackets shall be furnished for hanging, projecting, and double-sided signs. Mounting for framed, hanging, and projecting signs shall be by mechanical fasteners. Surface mounted signs shall be mounted with 1/16 inch thick vinyl foam tape fabricated from materials that are not corrosive to sign material and mounting surface.
2.1.4 Graphics
Signage graphics for modular signs shall conform to the following:
Subsurface copy: Copy is transferred to the back face of clear acrylic sheeting forming the panel face to produce precisely formed opaque image. This method bonds all sign elements (color, graphics, 10 14 02 - 3 lettering, braille and substrate) into a single unit.
2.1.5 Character Proportions and Heights
Letters and numbers on indicated signs which do not designate permanent rooms or spaces shall have a width-to-height ratio between 3:5 and 1:1 and a stroke-width-to-height ratio between 1:5 and 1:10. Characters and numbers on indicated signs shall be sized according to the viewing distance from which they are to be read. The minimum height is measured using an upper case letter "X". Lower case characters are permitted. Suspended or projected overhead signs shall have a minimum character height of 3 inches.
2.1.6 Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms)
Raised and brailled characters and symbols are only required on signs that designate permanent rooms or spaces, including restrooms and room numbers.
They are not required for information or way-finding signs. Raised letters and numbers on signs must protrude 1/32 inch upper case, sans serif or simple serif type and shall be accompanied with Grade 2 Braille. Raised characters shall be at least 5/8 inch in height, but no higher than 2 inches.
Pictograms shall be accompanied by the equivalent verbal description placed directly below the pictogram. The border dimension of the pictogram shall be 6 inches minimum in height. Indicated accessible facilities shall use the international symbol of accessibility.
2.2 BUILDING DIRECTORIES
Building directories shall be lobby directories or floor directories, and shall be provided with a changeable directory listing consisting of the areas, offices and personnel located within the facility. Dimensions, details, and materials of sign and message content shall be as shown on the drawingsand signage placement schedule.
2.2.1 Header Panel
Header panel shall be ES/MP plastic with raised letters.
2.2.2 Doors
2.2.2.1 Door Glazing
Door glazing shall be in accordance with ASTM C 1036, Type 1, Class 1, Quality 3, minimum 1/8 inch thick.
2.2.2.2 Door Construction
Extruded aluminum door frame shall be of same finish as surrounding frame.
Corners shall be mitered , welded, and assembled with concealed fasteners.
Hinges shall be standard with the manufacturer, in finish to match frames and trim. Glazing shall be set in frame with resilient glazing channels.
2.2.2.3 Door Locks
Door locks shall be manufacturer's standard, and shall be keyed alike.
2.2.3 Fabrication
Extruded aluminum frames and trim shall be assembled with corners welded and mitered to a hairline fit, with no exposed fasteners.
10 14 02 - 4
2.2.4 Changeable Letter/Message Strip Directory System
Directory shall consist of a non-illuminated unit with cast vinyl to receive molded changeable letter tiles. Design of unit shall be as shown in the drawings.
2.2.4.1 Construction
The directory shall be constructed of an aluminum 2 inch deep frame with satin dark bronze anodized finish. Unit shall be surface mounted. Unit shall have a 3 inch high header with lettering as shown. Unit shall have a 3/8 inch face concealed hinge door and locking system with tempered safety glass. Door frame shall be aluminum with satin dark bronze.
2.2.4.2 Message Strips
Namestrips shall be updatable by user with coupon book reordering and with 5 to 7 day delivery. Namestrips shall be acrylicsized in accordance with manufacturer's standard.
2.3 ALUMINUM ALLOY PRODUCTS
Aluminum extrusions shall be at least 1/8 inch thick, and aluminum plate or sheet shall be at least 0.0508 inch thick. Extrusions shall conform to ASTM B 221; plate and sheet shall conform to ASTM B 209. Where anodic coatings are specified, alloy shall conform to AA PK-1 alloy designation
514.0. Exposed anodized aluminum finishes shall be as shown. Welding for aluminum products shall conform to AWS D1.2/D1.2M.
2.4 ANODIC COATING
Anodized finish shall conform to AA DAF-45 as follows:
Integral color anodized designation AA-M10-C22-A32, Architectural Class
0.4 to 0.7 mil.
2.5 ORGANIC COATING
Organic coating shall conform to AAMA 2604, with total dry film thickness not less than 1.2 mils.
2.6 FABRICATION AND MANUFACTURE
2.6.1 Factory Workmanship
Holes for bolts and screws shall be drilled or punched. Drilling and punching shall produce clean, true lines and surfaces. Exposed surfaces of work shall have a smooth finish and exposed riveting shall be flush.
Fastenings shall be concealed where practicable.
2.6.2 Dissimilar Materials
Where dissimilar metals are in contact, the surfaces will be protected to prevent galvanic or corrosive action.
2.7 COLOR, FINISH, AND CONTRAST
Color shall be as indicated on the drawings. Finish of all signs shall be
10 14 02 - 5 eggshell, matte, or other non-glare finish as required in handicapped-accessible buildings.
PART 3 EXECUTION
3.1 INSTALLATION
Signs shall be installed plumb and true and in accordance with approved manufacturer's instructions at locations shown on the detail drawings.
Mounting height shall be 60 inch above the finish floor to the centerline of the sign. Distance from edge of door frame to edge of sign shall be as indicated on drawings. Required blocking shall be installed. Signs shall be installed on the wall adjacent to the latch side of the door. Where there is no wall space to the latch side of the door, including at double leaf doors, signs shall be placed on the nearest adjacent wall. Mounting location for such signage shall be so that a person may approach within 3 inches of signage without encountering protruding objects or standing within the swing of a door. Signs on doors or other surfaces shall not be installed until finishes on such surfaces have been installed. Signs installed on glass surfaces shall be installed with matching blank back-up plates in accordance with manufacturer's instructions.
3.1.1 Anchorage
Anchorage shall be in accordance with approved manufacturer's instructions. Anchorage not otherwise specified or shown shall include slotted inserts, expansion shields, and powder-driven fasteners when approved for concrete; toggle bolts and through bolts for masonry; machine carriage bolts for steel; lag bolts and screws for wood. Exposed anchor and fastener materials shall be compatible with metal to which applied and shall have matching color and finish. Where recommended by signage manufacturer, foam tape pads may be used for anchorage. Foam tape pads shall be minimum 1/16 inch thick closed cell vinyl foam with adhesive backing. Adhesive shall be transparent, long aging, high tech formulation on two sides of the vinyl foam. Adhesive surfaces shall be protected with a 5 mil green flatstock treated with silicone. Foam pads shall be sized for the signage in accordance with signage manufacturer's recommendations.
Signs mounted to painted gypsum board surfaces shall be removable for painting maintenance. Signs mounted to lay-in ceiling grids shall be mounted with clip connections to ceiling tees.
3.1.2 Protection and Cleaning
The work shall be protected against damage during construction. Hardware and electrical equipment shall be adjusted for proper operation. Glass, frames, and other sign surfaces shall be cleaned at completion of sign installation in accordance with the manufacturer's approved instructions.
-- End of Section --
10 14 02 - 6
10 14 02 - INTERIOR SIGNAGE
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 GENERAL
1.4 QUALIFICATIONS
1.5 DELIVERY AND STORAGE
1.6 EXTRA STOCK
PART 2 PRODUCTS
2.1 ROOM IDENTIFICATION/DIRECTIONAL SIGNAGE SYSTEM
2.1.1 Standard Room Signs
2.1.2 Changeable Message Strip Signs
2.1.3 Type of Mounting For Signs
2.1.4 Graphics
2.1.5 Character Proportions and Heights
2.1.6 Raised and Brailled Characters and Pictorial Symbol Signs Pictograms
2.2 BUILDING DIRECTORIES
2.2.1 Header Panel
2.2.2 Doors
2.2.2.1 Door Glazing
2.2.2.2 Door Construction
2.2.2.3 Door Locks
2.2.3 Fabrication
2.2.4 Changeable Letter/Message Strip Directory System
2.2.4.1 Construction
2.2.4.2 Message Strips
2.3 ALUMINUM ALLOY PRODUCTS
2.4 ANODIC COATING
2.5 ORGANIC COATING
2.6 FABRICATION AND MANUFACTURE
2.6.1 Factory Workmanship
2.6.2 Dissimilar Materials
2.7 COLOR, FINISH, AND CONTRAST
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Anchorage
3.1.2 Protection and Cleaning
SECTION 10 21 13
TOILET COMPARTMENTS
01/07 extent referenced. The publications are referred to within the text by the basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF-45 (2003) Designation System for Aluminum
ASTM A 123/A 123M (2008) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products
ASTM A 167 (1999; R 2004) Standard Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip
ASTM A 336/A 336M (2008) Standard Specification for Alloy Steel Forgings for Pressure and High-Temperature Parts
ASTM A 385 (2008) Standard Practice for Providing High-Quality Zinc Coatings (Hot-Dip)
ASTM A 653/A 653M (2008) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM B 36/B 36M (2008) Standard Specification for Brass Plate, Sheet, Strip, and Rolled Bar
ASTM B 456 (2003) Standard Specification for Electrodeposited Coatings of Copper Plus Nickel Plus Chromium and Nickel Plus Chromium
ASTM B 86 (2006) Standard Specification for Zinc and Zinc-Aluminum (ZA) Alloy Foundry and Die Castings
10 21 13 - 1
ASTM D 6386 (1999; R 2005) Standard Practice for Preparation of Zinc (Hot-Dip Galvanized) Coated Iron and Steel Product and Hardware Surfaces for Painting
INTERNATIONAL CODE COUNCIL (ICC)
ICC A117.1 (2003; R 2004) Standard for Accessible and Usable Buildings and Facilities
SOCIETY OF AUTOMOTIVE ENGINEERS INTERNATIONAL (SAE)
SAE AMS-QQ-C-320 (2000) Chromium Plating (Electrodeposited)-FSC MFFP
U.S. GENERAL SERVICES ADMINISTRATION (GSA)
CID A-A-60003 (Basic) Partitions, Toilet, Complete
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
Installation Drawings; G Fabrication Drawings
Drawings showing plans, elevations, details of construction, hardware, reinforcing, fittings, mountings, and anchorings for metal partitions and urinal screens. Installation drawings as specified.
Toilet Partition System; G Cleaning and Maintenance Instructions Colors And Finishes Galvanized Steel Sheet Sound Deadening Cores Partition Panels and Doors Anchoring Devices and Fasteners Hardware and Fittings Brackets Door Hardware Ceiling-Hung Partitions Floor-Anchored Partitions Overhead-Braced Partitions
10 21 13 - 2
Manufacturer's technical data and catalog cuts including installation and cleaning instructions.
Colors and Finishes; G
Manufacturer's standard color charts and color samples.
Partition Panels
Three samples showing a finished edge on two adjacent sides and core construction, each not less than 12-inch square
Hardware and Fittings Anchoring Devices and Fasteners
Three samples of each item. Approved hardware samples may be installed in the work if properly identified.
SD-07 Certificates
Certification
Documentation of product quality, as specified.
Waste Management
1.3 SYSTEM DESCRIPTION
Provide a complete and usable toilet partition system, including toilet enclosures, room entrance screens, urinal screens, system of panels, hardware, and support components. and Affirmative Procurement guidelines. Furnish the partition system from a single manufacturer, with a standard product as shown in the most recent catalog data. Submit Fabrication Drawings for metal toilet partitions and urinal screens consisting of fabrication and assembly details to be performed in the factory. Submit manufacturer's Cleaning and Maintenance Instructions with Fabrication Drawings for review.
1.4 REGULATORY REQUIREMENTS
Conform to ICC A117.1 code for access for the handicapped operation of toilet compartment door and hardware.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver materials in the manufacturer's original unopened packages with the brand, item identification, and project reference clearly marked. Store Components in a dry location that is adequately ventilated; free from dust, water, other contaminants, and damage during delivery, storage, and construction.
10 21 13 - 3
1.6 SUSTAINABLE DESIGN REQUIREMENTS
1.6.1 Local/Regional Materials
Use materials or products extracted, harvested, or recovered, as well as manufactured, within a 500 mile radius from the project site, if available from a minimum of three sources.See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total local material requirements. Toilet partition materials may be locally available.
1.7 WARRANTY
Provide Certification or warranties that metal toilet partitions will be free of defects in materials, fabrication, finish, and installation and will remain so for a period of not less than 5 years after completion.
1.8 FIELD MEASUREMENTS
Take field measurements prior to the preparation of drawing and fabrication to ensure proper fits.
2.1 MATERIALS
2.1.1 Galvanized Steel Sheet
Provide galvanized steel sheet cold-rolled, stretcher-level, commercial quality material, conforming to ASTM A 653/A 653M. Conform surface preparation of material for painting to ASTM D 6386, Method A.
2.1.2 Sound-Deadening Cores
Provide sound deadening consisting of treated kraft paper honeycomb cores with a cell size of not more than 1 inch. Resin-material content shall weigh not less than 11 percent of the finished core weight. Expanded cores shall be faced on both sides with kraft paper.
2.1.3 Anchoring Devices and Fasteners
Provide steel anchoring devices and fasteners hot-dipped galvanized after fabrication, in conformance with ASTM A 385 and ASTM A 123/A 123M. Conceal all galvanized anchoring devices.
2.1.4 Brackets
Wall brackets shall be two-ear panel brackets, T-style, 1-inch stock.
Provide stirrup style panel-to-pilaster brackets.
2.1.5 Hardware and Fittings
2.1.5.1 General Requirements
Conform hardware for the toilet partition system to CID A-A-60003 for the specified type and style of partitions. Provide hardware finish highly resistant to alkalies, urine, and other common toilet room acids. Comply latching devices and hinges for handicap compartments with 36 CFR 1191;
provide stainless steel devices and hinges with door latches that operate without either tight grasping or twisting of the wrist of the operator.
10 21 13 - 4
a. Conform cold-rolled sheet steel to ASTM A 336/A 336M, commercial quality.
b. Zinc-base alloy shall conform to ASTM B 86, Alloy AC41-A.
c. Brass shall conform to ASTM B 36/B 36M, Alloy C26800.
d. Aluminum shall conform to ASTM B 221.
e. Corrosion-resistant steel shall conform to ASTM A 167, Type 302.
2.1.5.2 Finishes
a. Chrome plating shall conform to ASTM B 456.
b. Finish shall conform to SAE AMS-QQ-C-320, Class I, Type I.
c. Aluminum shall have a clear anodic coating conforming to AA DAF-45.
d. Corrosion-resistant steel shall have a No. 4 finish.
e. Exposed fasteners shall match the hardware and fittings.
2.1.6 Door Hardware
2.1.6.1 Hinges
Provide self-lubricating hinges with the indicated swing. Hinges shall be the surface-mounted type.
Hinge shall be adjustable to hold in-swinging doors open at any angle up to 90 degrees and outswinging doors to 10 degrees.
2.1.6.2 Latch and Pull
Latch and pull shall be a combination rubber-faced door strike and keeper equipped with emergency access.
2.1.6.3 Coat Hooks
Coat hooks shall be combination units with hooks and rubber tipped pins.
2.2 PARTITION PANELS AND DOORS
Provide partition panels and doors not less than 1 inch thick with face sheets not less than 0.0396 inch thick.
2.2.1 Toilet Enclosures
Conform toilet enclosures to CID A-A-60003, Type I, Style C, overhead braced.
Furnish width, length, and height of toilet enclosures as shown. Provide a width of 1 inch. Finish surface of panels shall be solid polyethylene, Finish 5; water resistant; graffiti resistant; non-absorbent. See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total recycled content requirements. This item may contain post-consumer or post-industrial recycled content. Reinforce panels indicated to receive toilet paper holders or grab bars for mounting of the items required. Provide grab bars to withstand a bending stress, shear stress, shear force, and a tensile
10 21 13 - 5 force induced by 250 lbf. Grab bars shall not rotate within their fittings.
2.2.2 Room Entrance Screens
Conform room entrance screens to CID A-A-60003, Type II, Style C, overhead braced. Finish surface of screens shall be solid polyethylene, Finish 5;
water resistant; graffiti resistant; non-absorbent; 1/4 inch radius beveled edges. See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total recycled content requirements. This item may contain post-consumer or post-industrial recycled content. Furnish length and height of screens as shown. Provide thickness of 1 inch. Fabricate screens from the same types of panels, pilasters, and fittings as the toilet partitions.
2.2.3 Urinal Screens
Conform urinal screens to CID A-A-60003, Type III, Style D, floor to ceiling hung. Provide finish for surface of screens as solid polyethylene, Finish 5; water resistant; graffiti resistant; non-absorbent; 1/4 inch radius beveled edges. See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total recycled content requirements. This item may contain post-consumer or post-industrial recycled content. Furnish width and height of urinal screens as shown. Provide thickness of 1 inch. Secure wall hung urinal screens with 42 inch long, continuous flanges. Fabricat screens from the same types of panels and pilasters as the toilet partitions. Use corrosion-resistant steel fittings and fasteners.
2.3 OVERHEAD-BRACED PARTITIONS
Pilasters shall be not less than 1-1/4 inch thick with face sheets not less than 0.0393 inch thick. Provide anchoring device at the bottom of the pilaster consistingof a channel-shaped floor stirrup fabricated from not less than 0.0635 inch thick material and a leveling bolt. Secure the stirrup to the pilaster with not less than a 3/16 inch bolt and nut after the pilaster is leveled. Secure the stirrup to the floor with not less than two lead expansion shields and sheetmetal screws. Fabricate overhead brace from a continuous extruded aluminum tube not less than 1 inchwide by 1-1/2 inch high, 0.125-inch wall thickness. Finish shall be AA-C22A31 in accordance with AA DAF-45. Set and secure brace into the top of each pilaster. Fabricate 3 inch high trim piece at the floor from not less than
0.030 inch thick corrosion-resistant steel.
2.4 PILASTER SHOES
Provide shoes at pilasters to conceal floor-mounted anchorage. Pilaster shoes shall be stainless steel. See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total recycled content requirements. Pilaster shoes may contain post-consumer or post-industrial recycled content.
Height shall be 3 inches.
2.5 HARDWARE
Hardware for the toilet partition system shall conform to CID A-A-60003 for the specified type and style of partitions. Hardware shall be pre-drilled by manufacturer. Hardware finish shall be highly resistant to alkalies, urine, and other common toilet room acids. Hardware shall include: chrome plated non ferrous cast pivot hinges, gravity type, adjustable for door close positioning; nylon bearings; black anodized aluminum door latch; door strike and keeper with rubber bumper; and cast alloy chrome plated coat hook and bumper. Latching devices and hinges for handicap compartments
10 21 13 - 6 shall comply with 36 CFR 1191 and shall be stainless steel door latches that operate without either tight grasping or twisting of the wrist of the operator. Screws and bolts shall be stainless steel, tamper proof type.
Wall mounting brackets shall be continuous, full height, stainless steel, in accordance with toilet compartment manufacturer's instructions.
Floor-mounted anchorage shall consist of corrosion-resistant anchoring assemblies with threaded rods, lock washers, and leveling adjustment nuts at pilasters for structural connection to floor.
2.6 COLORS AND FINISHES
2.6.1 Colors
Provide manufacturer's standard color charts for color of finishes for toilet partition system components.
2.6.2 Finishes No.4 and No. 5
Provide solid plastic fabricated of polymer resins (polyethylene) formed under high pressure rendering a single component section not less than one inch thick. Colors shall extend throughout the panel thickness. Provide exposed finish surfaces: smooth, waterproof, non-absorbant, and resistant to staining and marking with pens, pencils, or other writing devices.
Solid plastic partitions shall not show any sign of deterioration when immersed in the following chemicals and maintained at a temperature of 80 degrees F for a minimum of 30 days:
Acetic Acid (80 percent) Hydrochloric Acid (40 percent) Acetone Hydrogen Peroxide (30 percent) Ammonia (liquid) Isopropyl Alcohol Ammonia Phosphate Lactic Acid (25 percent) Bleach (12 percent) Lime Sulfur Borax Nicotine Brine Potassium Bromide Caustic Soda Soaps Chlorine Water Sodium Bicarbonate Citric Acid Trisodium Phosphate Copper Chloride Urea; Urine Core Oils Vinegar
3.1 PREPARATION
Verify that field measurements, surfaces, substrates and conditions are as required, and ready to receive work. Verify correct spacing of plumbing fixtures. Verify correct location of built in framing, anchorage, and bracing. Report in writing to Contracting Officer prevailing conditions that will adversely affect satisfactory execution of the work of this section. Do not proceed with work until unsatisfactory conditions have been corrected.
3.2 METAL PARTITION FABRICATION
a. Fabricate metal Partition Panels, doors, screens, and pilasters required for the project from galvanized-steel face sheets with formed edges. Face sheets shall be pressure-laminated to the sound-deadening core with edges sealed with a continuous locking strip and corners mitered and welded. Ground all welds smooth. Provide concealed reinforcement for
10 21 13 - 7 installation of hardware, fittings, and accessories. Surface of face sheets shall be smooth and free from wave, warp, or buckle.
b. Before application of an enamel coating system, solvent-clean galvanized-steel surfaces to remove processing compounds, oils, and other contaminants harmful to coating-system adhesion. After cleaning,coat the surfaces with a metal-pretreatment phosphate coating. After pretreatment, finish exposed galvanized-steel surfaces with a baked-enamel coating system as specified.
c. Provide an enamel coating system consisting of a factory-applied baked acrylic enamel coating system. Coating system shall be a durable, washable, stain-resistant, mar-resistant finish.
3.3 INSTALLATION
Install partitions rigid, straight, plumb, and level, with the panels centered between the fixtures. Provide a panel clearance of not more than 1/2 inch and secure the panels to walls and pilasters with not less than two wall brackets attached near the top and bottom of the panel. Locate wall brackets so that holes for wall bolts occur in masonry or tile joints. Secure Panels to pilasters with brackets matching the wall brackets. Provide for adjustment due to minor floor variations. Locate head rail joints at pilaster center lines. Install adjacent components for consistency of line and plane. Equip each door with hinges, one door latch, and one coat hook and bumper. Align hardware to uniform clearance at vertical edges of doors.
a. Secure panels to hollow plastered walls with toggle bolts using not less than 1/4-20 screws of the length required for the wall thickness.
Toggle bolts shall have a load-carrying strength of not less than 600 pounds per anchor.
b. Secure panels to ceramic tile on hollow plastered walls or hollow concrete-masonry walls with toggle bolts using not less than 1/4-20 screws of the length required for the wall thickness. Toggle bolts shall have a load-carrying strength of not less than 600 pounds per anchor.
c. Secure panels to solid masonry or concrete with lead or brass expansion shields designed for use with not less than 1/4-20 screws, with a shield length of not less than 1-1/2 inch. Expansion shields shall have a load-carrying strength of not less than 600 pounds per anchor.
d. Submit Installation Drawings for metal toilet partitions and urinal screens showing plans, elevations, details of construction, hardware, reinforcing and blocking, fittings, mountings and escutcheons.
Indicate on drawingsthe type of partition, location, mounting height, cutouts, and reinforcement required for toilet-room accessories.
3.4 CEILING-HUNG PARTITIONS
Secure pilasters to the structural support above with the anchorage device specified. Make all leveling devices readily accessible for leveling, plumbing, and tightening the installation. Level the bottoms of doors with bottoms of pilasters when doors are in a closed position.
10 21 13 - 8
3.5 FLOOR-ANCHORED PARTITIONS
Secure pilasters to the floor with the anchorage device specified. Make all leveling devices readily accessible for leveling, plumbing, and tightening the installation. level tops of doors with tops of pilasters when doors are in a closed position. Expansion shields shall have a minimum 2-inch penetration into the concrete slab.
3.6 OVERHEAD-BRACED PARTITIONS
Secure pilasters to the floor with the anchorage device specified. Make all leveling devices readily accessible for leveling, plumbing, and tightening the installation. Secure overhead brace to the pilaster face with not less than two fasteners per face. Expansion shields shall have a minimum 2-inch penetration into the concrete slab. Tops of doors must be parallel with the overhead brace when doors are in a closed position.
3.7 FINAL ADJUSTMENT
After completion of the installation, make final adjustments to the pilaster-leveling devices, door hardware, and other working parts of the partition assembly. Doors shall have a uniform vertical edge clearance of approximately 3/16 inch and shall rest open at approximately 30 degrees when unlatched.
3.8 CLEANING
Baked enamel finish shall be touched up with the same color of paint that was used for the finish. Clean all surfaces of the work, and adjacent surfaces soiled as a result of the work, in an approved manner compliant with the manufacturer's recommended cleaning and protection from damage procedures until accepted. Remove all equipment, tools, surplus materials, and work debris from the site.
3.9 WASTE MANAGEMENT
Identify manufacturer's policy for collection or return of construction scrap, demolition scrap, unused material and packaging material. Institute demolition and construction waste separation and recycling to take advantage of manufacturer's programs. When such a service is not available, seek local recyclers to reclaim the materials.
10 21 13 - 9
10 21 13 - TOILET COMPARTMENTS
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 SYSTEM DESCRIPTION
1.4 REGULATORY REQUIREMENTS
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 SUSTAINABLE DESIGN REQUIREMENTS
1.6.1 Local/Regional Materials
1.7 WARRANTY
1.8 FIELD MEASUREMENTS
PART 2 PRODUCTS
2.1 MATERIALS
2.1.1 Galvanized Steel Sheet
2.1.2 Sound-Deadening Cores
2.1.3 Anchoring Devices and Fasteners
2.1.4 Brackets
2.1.5 Hardware and Fittings
2.1.5.1 General Requirements
2.1.5.2 Finishes
2.1.6 Door Hardware
2.1.6.1 Hinges
2.1.6.2 Latch and Pull
2.1.6.3 Coat Hooks
2.2 PARTITION PANELS AND DOORS
2.2.1 Toilet Enclosures
2.2.2 Room Entrance Screens
2.2.3 Urinal Screens
2.3 OVERHEAD-BRACED PARTITIONS
2.4 PILASTER SHOES
2.5 HARDWARE
2.6 COLORS AND FINISHES
2.6.1 Colors
2.6.2 Finishes No.4 and No. 5
PART 3 EXECUTION
3.1 PREPARATION
3.2 METAL PARTITION FABRICATION
3.3 INSTALLATION
3.4 CEILING-HUNG PARTITIONS
3.5 FLOOR-ANCHORED PARTITIONS
3.6 OVERHEAD-BRACED PARTITIONS
3.7 FINAL ADJUSTMENT
3.8 CLEANING
3.9 WASTE MANAGEMENT
SECTION 10 26 13
WALL AND CORNER GUARDS
04/06
ASTM D 256 (2006e1) Determining the Izod Pendulum Impact Resistance of Plastics
ASTM D 543 (2006) Standard Practices for Evaluating the Resistance of Plastics to Chemical Reagents
ASTM D 635 (2006) Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position
ASTM E 84 (2008a) Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM G 21 (1996; R 2002) Determining Resistance of Synthetic Polymeric Materials to Fungi
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 80 (2006; Errata 2008) Standard for Fire Doors and Other Opening Protectives
SOCIETY OF AUTOMOTIVE ENGINEERS INTERNATIONAL (SAE)
SAE J1545 (2005) Instrumental Color Difference Measurement for Exterior Finishes, Textiles and Colored Trim used, a designation following the "G" designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
10 26 13 - 1
Corner Guards
Drawings indicating locations and typical elevations of each type of item. Drawings shall show vertical and horizontal dimensions, full size sections, thickness of materials, and fastening details.
Manufacturer's descriptive data, catalog cuts, installation instructions, and recommended cleaning instructions.
Finish; G
Submit three samples indicating color and texture of materials requiring color and finish.
SD-06 Test Reports
Fire rating and extinguishing test results for resilient material.
Statements attesting that the items comply with specified fire and safety code requirements.
1.3 DELIVERY AND STORAGE
Materials shall be delivered to the project site in manufacturer's original unopened containers with seals unbroken and labels and trademarks intact.
Materials shall be kept dry, protected from weather and damage, and stored under cover. Materials shall be stored at approximately 70 degrees F for at least 48 hours prior to installation.
1.4 WARRANTY
Manufacturer's standard performance guarantees or warranties that extend beyond a 1 year period shall be provided.
2.1 GENERAL
To the maximum extent possible, corner guards, door and door frame protectors, wall guards (bumper guards), wall panels and wall covering shall be the standard products of a single manufacturer and shall be furnished as detailed. Drawings show general configuration of products required, and items differing in minor details from those shown will be
10 26 13 - 2 acceptable.
2.1.1 Resilient Material
Resilient material shall consist of high impact resistant extruded acrylic vinyl, polyvinyl chloride, or injection molded thermal plastic and shall conform to the following:
2.1.1.1 Minimum Impact Resistance
Minimum impact resistance shall be 18 ft-lbs/sq. inch when tested in accordance with ASTM D 256, (Izod impact, ft-lbs per sq inch notched).
2.1.1.2 Fire Rating
Fire rating shall be Class 1 when tested in accordance with ASTM E 84, having a maximum flame spread of 25 and a smoke developed rating of 450 or less. Material shall be rated self extinguishing when tested in accordance with ASTM D 635. Material shall be labeled and tested by an approved nationally known testing laboratory. Resilient material used for protection on fire rated doors and frames shall be listed by the testing laboratory performing the tests. Resilient material installed on fire rated wood/steel door and frame assemblies shall have been tested on similar type assemblies. Test results of material tested on any other combination of door/frame assembly will not be acceptable.
2.1.1.3 Integral Color
Colored components shall have integral color and shall be matched in accordance with SAE J1545 to within plus or minus 1.0 on the CIE-LCH scales.
2.1.1.4 Chemical and Stain Resistance
Materials shall be resistant to chemicals and stains reagents in accordance with ASTM D 543.
2.1.1.5 Fungal and Bacterial Resistance
Materials shall be resistant to fungi and bacteria in accordance with ASTM G 21, as applicable.
2.2 CORNER GUARDS
2.2.1 Resilient Corner Guards
Corner guard units shall be surface mounted type, radius formed to profile shown. Corner guards shall be 6 feet high. Mounting hardware, cushions, and base plates shall be furnished. Assembly shall consist of a snap-on corner guard formed from high impact resistant resilient material, minimum
0.078 inch thick, mounted on a continuous aluminum retainer. Extruded aluminum retainer shall conform to ASTM B 221, alloy 6063, temper T5 or T6. Flush mounted type guards shall act as a stop for adjacent wall finish material. Factory fabricated end closure caps shall be furnished for top and bottom of surface mounted corner guards. Flush mounted corner guards installed in fire rated wall shall maintain the rating of the wall.
Insulating materials that are an integral part of the corner guard system shall be provided by the manufacturer of the corner guard system. Exposed metal portions of fire rated assemblies shall have a paintable surface.
10 26 13 - 3
2.3 FINISH
2.3.1 Resilient Material Finish
Finish for resilient material shall be embossed stipple texture with colors in accordance with SAE J1545.
2.4 ADHESIVES
Adhesive for resilient material shall be in accordance with manufacturers recommendations.
2.5 COLOR
Color shall be as indicated on the drawings.
3.1.1 Corner Guards and Wall Guards (Bumper Guards)
Material shall be mounted at location indicated in accordance with manufacturer's recommendations.
3.1.2 Door, Door Frame Protectors, and Wall Panels
Surfaces to receive protection shall be clean, smooth, and free of obstructions. Protectors shall be installed after frames are in place, but prior to hanging of doors, in accordance with manufacturer's specific instructions. Adhesives shall be applied in controlled environment in accordance with manufacturer's recommendations. Protection for fire doors and frames shall be installed in accordance with NFPA 80.
10 26 13 - 4
10 26 13 - WALL AND CORNER GUARDS
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 DELIVERY AND STORAGE
1.4 WARRANTY
PART 2 PRODUCTS
2.1 GENERAL
2.1.1 Resilient Material
2.1.1.1 Minimum Impact Resistance
2.1.1.2 Fire Rating
2.1.1.3 Integral Color
2.1.1.4 Chemical and Stain Resistance
2.1.1.5 Fungal and Bacterial Resistance
2.2 CORNER GUARDS
2.2.1 Resilient Corner Guards
2.3 FINISH
2.3.1 Resilient Material Finish
2.4 ADHESIVES
2.5 COLOR
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Corner Guards and Wall Guards Bumper Guards
3.1.2 Door, Door Frame Protectors, and Wall Panels
SECTION 10 28 13
TOILET ACCESSORIES
07/06
ASTM C 1036 (2006) Standard Specification for Flat Glass used, a designation following the "G" designation identifies the office
Accessory Items; G
Manufacturer's descriptive data and catalog cuts indicating materials of construction, fasteners proposed for use for each type of wall construction, mounting instructions, operation instructions, and cleaning instructions.
Accessory Items
One sample of each accessory proposed for use. Incorporate approved samples into the finished work, provided they are identified and their locations noted.
Accessory Items
Certificate for each type of accessory specified, attesting that the items meet the specified requirements.
Electric Hand Dryer complete copies of maintenance instructions listing routine
10 28 13 - 1 maintenance procedures and possible breakdowns. Include repair instructions for simplified wiring and control diagrams and other information necessary for unit maintenance.
1.3 DELIVERY, STORAGE, AND HANDLING
Wrap toilet accessories for shipment and storage, then deliver to the jobsite in manufacturer's original packaging, and store in a clean, dry area protected from construction damage and vandalism.
1.4 WARRANTY
Provide manufacturer's standard performance guarantees or warranties that extend beyond a 1 year period.
2.1 MANUFACTURED UNITS
Provide toilet accessories shall be provided where indicated in accordance with paragraph SCHEDULE. Porcelain type, tile-wall accessories are specified in Section 09 30 00 CERAMIC TILE QUARRY TILE, AND PAVER TILE.
Provide each accessory item shall be complete with the necessary mounting plates of sturdy construction with corrosion resistant surface.
2.1.1 Anchors and Fasteners
Provide anchors and fasteners capable of developing a restraining force commensurate with the strength of the accessory to be mounted and suited for use with the supporting construction. Provide tamperproof design exposed fasteners with finish to match the accessory.
2.1.2 Finishes
Except where noted otherwise, provide the following finishes on metal:
Metal Finish
Stainless steel No. 4 satin finish
Carbon steel, copper alloy, Chromium plated, bright and brass
2.2 ACCESSORY ITEMS
Conform to the requirements for accessory items specified below.
2.2.1 Grab Bar (GB)
Provide an 18 gauge, 1-1/4 inch grab bar OD Type 304 stainless steel.
Provide form and length for grab bar as indicated. Provide concealed mounting flange. Provide grab with satin finish. Furnish installed bars capable of withstanding a 500 pound vertical load without coming loose from the fastenings and without obvious permanent deformation. Allow 1-1/2 inch space between wall and grab bar.
10 28 13 - 2
2.2.2 Mirrors, Glass (MG)
Provide Type I transparent flat type, Class 1-clear glass for mirrors.
Glazing Quality q1 1/4 inch thick conforming to ASTM C 1036. Coat glass on one surface with silver coating, copper protective coating, and mirror backing paint. Provide highly adhesive pure silver coating of a thickness which provides reflectivity of 83 percent or more of incident light when viewed through 1/4 inch thick glass, free of pinholes or other defects.
Provide copper protective coating with pure bright reflective copper, homogeneous without sludge, pinholes or other defects, of proper thickness to prevent "adhesion pull" by mirror backing paint. Provide mirror backing paint with two coats of special scratch and abrasion-resistant paint and baked in uniform thickness to provide a protection for silver and copper coatings which will permit normal cutting and edge fabrication.
2.2.3 Mirror, Tilt (MT)
Provide surface mounted tilt mirror with full visibility for persons in a wheelchair. Furnish adjustable tilt mirror, extending at least 4 inch from the wall at the top and tapering to 1 inch at the bottom. Provide size in accordance with the drawings. Conform to ASTM C 1036 and paragraph Glass Mirrors.
2.2.4 Paper Towel Dispenser (PTD)
Provide paper towel dispenser constructed of a minimum 0.03 inch Type 304 stainless steel, surface mounted. Provide a towel compartment and a for each dispenser. Furnish tumbler key lock locking mechanism.
2.2.5 Combination Paper Towel Dispenser/Waste Receptacle (PTDWR)
Provide semi-recessed dispenser/receptacle with a capacity of 600 sheets of C-fold, single-fold, or quarter-fold towel. Design waste receptacle to be locked in unit and removable for service. Provide tumbler key locking mechanism. Provide waste receptacle capacity of 18 gallons. Fabricate a minimum 0.03 inch stainless steel welded construction unit with all exposed surfaces having a satin finish. Provide waste receptacle that accepts reusable liner standard for unit manufacturer.
2.2.6 Sanitary Napkin Disposer (SND)
Construct a Type 304 stainless steel sanitary napkin disposal with removable leak-proof receptacle for disposable liners. Provide fifty disposable liners of the type standard with the manufacturer. Retain receptacle in cabinet by tumbler lock. Provide disposer with a door for inserting disposed napkins, surface mounted.
2.2.7 Sanitary Napkin and Tampon Dispenser (SNTD)
Provide sanitary napkin and tampon dispenser surface mounted. Dispenser, including door of Type 304 stainless steel that dispense both napkins and tampons with a minimum capacity of 20 each. Furnish dispensing mechanism for coin operation. Provide coin mechanisms with minimum denominations of 10 cents, 25 cents, 50 cents. Hang doors with a full-length corrosion-resistant steel piano hinge and secure with a tumbler lock.
Provide keys for coin box different from the door keys.
10 28 13 - 3
2.2.8 Shower Curtain (SC)
Provide shower curtain, size to suit conditions. Provide anti-bacterial nylon/vinyl fabric curtain.
2.2.9 Shower Curtain Rods (SCR)
Provide Type 304 stainless steel shower curtain rods 1-1/4 inch OD by 0.049 inch minimum straight to meet installation conditions.
2.2.10 Soap Dispenser (SD)
Provide soap dispenser lavatory mounted, liquid type consisting of a polyethylene tank with a minimum 32 fluid ounces holding capacity and a 6 inch spout length.
2.2.11 Soap Holder (SH)
Provide surface mounted Type 304 stainless steel soap holder. Provide stainless steel separate supports.
2.2.12 Shelf, Metal, Heavy Duty (SMHD)
Furnish a minimum 18 gauge stainless steel heavy duty metal shelf with hemmed edges. Provide shelves over 30 inch with intermediate supports.
Provide minimum of 16 gauge supports, welded to the shelf, and spaced no more than 30 inch apart.
2.2.13 Towel Bar (TB)
Provide stainless steel towel bar with a minimum thickness of 0.015 inch.
Provide minimum 3/4 inch diameter bar, or 5/8 inch square. Provide satin finish.
2.2.14 Towel Pin (TP)
Provide towel pin with concealed wall fastenings, and a pin integral with or permanently fastened to wall flange with maximum projection of 4 inch.
Provide satin finish.
2.2.15 Toilet Tissue Dispenser, Jumbo (TTDJ)
Provide surface mounted toilet tissue dispenser with 2 rolls of jumbo tissue. Fabricate cabinet of high-impact plastic body and transparent plastic front cover. Provide cover with key lock.
2.2.16 Waste Receptacle (WR)
Provide Type 304 stainless steel waste receptacle, designed for recessed mounting. Provide reuseable liner, of the type standard with the receptacle manufacturer. Provide a minimum [_____] cubic feet capacity.
Provide receptacles with push doors and doors for access to the waste compartment with continuous hinges. Furnish tumbler key lock locking mechanism.
2.2.17 Toilet Seat Cover Dispenser (TSCD)
Provide Type 304 stainless steel with surface mounted toilet seat cover dispensers. Provide dispenser with a minimum capacity of 500 seat covers.
10 28 13 - 4
2.2.18 Electric Hand Dryer (EHD)
Provide wall mount and electric hand dryer designed to operate at 110/125 volts, 60 cycle, single phase alternating current with a heating element core rating of a maximum 2100 watts. Provide dryer housing of single piece construction and of baked electrostatically applied epoxy.
Provide the same finish for the surfaces of fastening devices exposed after installation as the attached accessory. Provide oval exposed screw heads.
Install accessories at the location and height indicated. Protect exposed surfaces of accessories with strippable plastic or by other means until the installation is accepted. After acceptance of accessories, remove and dispose of strippable plastic protection. Coordinate accessory manufacturer's mounting details with other trades as their work progresses. Use sealants for brackets, plates, anchoring devices and similar items in showers (a silicone or polysulphide sealant) as they are set to provide a watertight installation. After installation, thoroughly clean exposed surfaces and restore damaged work to its original condition or replace with new work.
3.1.1 Recessed Accessories
Fasten accessories with wood screws to studs, blocking or rough frame in wood construction. Set anchors in mortar in masonry construction. Fasten to metal studs or framing with sheet metal screws in metal construction.
3.1.2 Surface Mounted Accessories
Mount on concealed backplates, unless specified otherwise. Conceal fasteners on accessories without backplates. Install accessories with sheet metal screws or wood screws in lead-lined braided jute, teflon or neoprene sleeves, or lead expansion shields, or with toggle bolts or other approved fasteners as required by the construction.
This is the start of the file's text. The full file is on GovTribe.