Technical_Exhibit_D.pdf
PDF 186 KB Posted
- Solicitation number
- W912PF-16-T-0028
About this file
Technical Exhibit D
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_0001.pdf | ||
| TE_C3_Del_Din.pdf | ||
| TE_A2_Inventory_Villaggio.xlsx | XLSX spreadsheet | |
| TE_C1_Ederle.pdf | ||
| TE_A6_Inventory_ASP_7Tormeno.xlsx | XLSX spreadsheet | |
| MFR_Technical_Exhibit_B.pdf | ||
| TE_C8_Poggio_Renatico.pdf | ||
| TE_A4_Inventory_Poggio_Renatico.xlsx | XLSX spreadsheet | |
| TE_C6_Lerino.pdf | ||
| TE_C2_Villaggio_della_Pace.pdf | ||
| TE_A7_Inventory_Lerino.xlsx | XLSX spreadsheet | |
| SOLICITATION_W912PF-16-T-0028.pdf | ||
| Attachment_1_AntiMafia.pdf | ||
| Attachment_2_Past_Performance_Questionnaire.pdf | ||
| TE_A3_Inventory_Del_Din.xlsx | XLSX spreadsheet | |
| TE_C4_Longare.pdf | ||
| TE_C7_Torri_di_Quartesolo.pdf | ||
| TE_C5_ASP_7_Tormeno.pdf | ||
| TE_A8_Inventory_Torri.xlsx | XLSX spreadsheet | |
| TE_A5_Inventory_Longare.xlsx | XLSX spreadsheet | |
| Performance_Work_Statement_Draft.docx | DOCX document |
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contract: W912PF-15-C-0006 Page: 1 of 1 Date: 21-Nov-16
1 Pass Not Pass 2 Pass Not Pass 3 Pass Not Pass 4 Pass Not Pass 5 Pass Not Pass 6 Pass Not Pass 7 Pass Not Pass 8 Pass Not Pass 9 Pass Not Pass
10 Pass Not Pass
TECHNICAL EXHIBIT D
FIRE ALARM SYSTEMACME
Test all the devices connected to the Fire Alarm System
Mario Rossi
ACTIVITY DESCRIPTION Result
Test and clean the smoke/heat detector Test voltage level FACP Test voltage level auxiliary external batteries of the FACP
Area: Ederle BLDG: 3 Name/lastname:
Test UPS of mass notification Test functional mass notification Test functional fire alarm
Description of the deficiencies: The smoke detector N. L01 M 23 (Model, Type) located in the room 96 is missing, the heat detector N. L01 M 29 (Model, Type) located in the room 105 not working properly needs to be replaced, the strobe N L01 M 27 (Model, Type) located in the room 1040 is broken needs to be replaced, the mass notification battery (Model, Type) not working needs to be replaced
Number of pull station: 32
Connection with Fire Department: Yes
Test the connection with Fire department
Mass Notification system: Yes
Fire Alarm Panel: NOTIFIER AM 2000N Number of detectors: 41
Test other devices Fault test FACP
Contract: W912PF-15-C-0006 Page: 1 of 1 Date: 21-Nov-16
SERIAL NUMBER LOCATION Revisione Collaudo Ricarica 1 SN 124260 Piano terra, corridoio lato destro 2017 2019 NO 2 SN 124261 Piano terra, stanza elettrica Room 52 YES 2018 NO 3 SN 124262 Primo piano, corridoio lato sinisteo 2018 2020 YES
TECHNICAL EXHIBIT D
FIRE EXTINGUISHER
Area: Ederele BLDG: 3 Name/lastname: Mario Rossi
Type of Service
Note: fatto servizio di revisione per 1 estintore e una ricarica, tutti gli estintori risultano essere funzionanti ed in buone condizioni
TYPE OF FIRE EXTINGUISHER
Estintore a polvere da 6KG Estintore a polvere da 6KG Estintore a polvere da 6KG
ACME
BLDG Number Semester PWS Issue Description Location QTY Item Estimate material Etimate Hours 1 A 4.1.3 rilevatore di fumo stanza 11‐ 2 piano 2 Notifire NFXI‐SMT2 135x2=270 2 ore 1 A 4.1.9 Luce di emergenza corridoio 1 piano 8 Disano 615 safety 123x8=984 10 ore 2 A 4.1.5 Pressostato stanza sprinkler 1 Tyco PS‐10‐2 292.12 3 ore 2 A 4.1.3 Batteria FAP Entrata piano terra 2 prezziario DEI 62x2=322.62 1 ora
EDERLE
TECHNICAL EXHIBIT D
| FIRE ALARM |
| FIRE EXTINGUISHER |