TE_A5_Inventory_Longare.xlsx

XLSX spreadsheet 59 KB Posted

Attached to
Inspection & Testing of Fire Suppression System, Vicenza, Italy
Solicitation number
W912PF-16-T-0028
Issued by

About this file

Technical Exhibit A_5

View the file

Other files

File Type Posted
Amendment_0001.pdf PDF
TE_C3_Del_Din.pdf PDF
TE_A2_Inventory_Villaggio.xlsx XLSX spreadsheet
TE_C1_Ederle.pdf PDF
Technical_Exhibit_D.pdf PDF
TE_A6_Inventory_ASP_7Tormeno.xlsx XLSX spreadsheet
MFR_Technical_Exhibit_B.pdf PDF
TE_C8_Poggio_Renatico.pdf PDF
TE_A4_Inventory_Poggio_Renatico.xlsx XLSX spreadsheet
TE_C6_Lerino.pdf PDF
TE_C2_Villaggio_della_Pace.pdf PDF
TE_A7_Inventory_Lerino.xlsx XLSX spreadsheet
SOLICITATION_W912PF-16-T-0028.pdf PDF
Attachment_1_AntiMafia.pdf PDF
Attachment_2_Past_Performance_Questionnaire.pdf PDF
TE_A3_Inventory_Del_Din.xlsx XLSX spreadsheet
TE_C4_Longare.pdf PDF
TE_C7_Torri_di_Quartesolo.pdf PDF
TE_C5_ASP_7_Tormeno.pdf PDF
TE_A8_Inventory_Torri.xlsx XLSX spreadsheet
Performance_Work_Statement_Draft.docx DOCX document
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Longare Site (VI)

Room Number:
Numero della Stanza:Room Type:
Destinazione d'uso della stanza:False ceiling:
Controsoffitto:Raised floor:
Pavimento sopraelevato:Fire Rated Doors:
Porte tagliafuoco:Emergency exit:
Uscita di emergenza:Fire dampers:
Serrande tagliafuoco:Smoke and Heat Clearance Vents:
Evacuatori di fumo e calore:Fire extinguishers:
Estintori:Hydrants:
Idranti:Hose Reels:
Naspi:Sprinkler System:
Impianto di spegnimento ad acqua:Fire Suppression System:
Impianto di spegnimento a gas:Fire Alarm System:
Sistema di allarme antincendio:Mass notification [num. of speakers]:
Impianto notificazione allarmi [num. di casse]:Emergency & safety lights:
Luci di emergenza e di sicurezza:Other Fire Prevention/Protection Devices:

Altri dispositivi di protezione/prevenzione:

Q.tyREIpanic hwAlso emergencyQ.typanic hwQ.tyExtinguishing agentWeight [kg]classes
[#A #B etc.]n. headsn. heads in false ceilingsystem type
[W, D, M]n. headsn. cylindersWeight [kg]Extinguishing agentpanel typen. sens.n. sens. in false ceilingn. sens. in raised floorsensor type
[F, T, G]pull stationacoust. alarmstrobescombo strobe / alarm
Building:
Edificio:Floor:
Piano:Q.tàREImaniglioneAnche emergenzaQ.tàmaniglioneQ.tàEstinguentePeso [kg]classi
[#A #B etc.]n. ugellin. ugelli nel controsoffittotipo impianto [W, D, M]n. ugellin. bombolePeso [kg]Estinguentetipo centralinan. sens.n. sens. nel controsoffitton. sens. sotto pavimentotipo sensore
[F, T, G]pulsantiallarme acust.lamp.comb. lamp. / allarme
1GF0115CONFERENCE RMNN----1Y--2POWDER634A 233B C----------4--F-----1-
1GF0114OFFICENN----------------------2--F------EVACUATION PLAN
1GF0113TOILETNN----------------------2--F-------
1GF0116OFFICENN----------------------2--F------EVACUATION PLAN
1GF0117OFFICENN----------------------2--F------EVACUATION PLAN
1GF01111TOILETNN----------------------1--F-------
1GF0112OFFICEYN----------------------11-F-----1EVACUATION PLAN
1GF0110OFFICENN----------------------1--F------EVACUATION PLAN
1GF0118BREAK RMNN----------------------1--F-------
1GF0120VESTIBULENN----1Y----------------1--F-------
1GF*003STORAGENN---------------------------------
1GF-ENTRY 1NN160NY1Y--------------------1----2-
1GF0109OFFICENN----------------------1--F------EVACUATION PLAN
1GF109ATOILETNN---------------------------------
1GF0107STORAGENN----------------------2--F-------
1GF0104STORAGENN----------------------2--F-----13 100mA AND 4 3000 mA MAGN. RES. CURR. BR.
1GF0103OFFICENN----------------------2--F-------
1GF0102ARMS RMNN--------1POWDER634A 233B C----------1--F-------
1GF-ENTRY 2NN----1Y--2POWDER634A 233B C----------2--F---1---
1GF-HALLWAY 3NN----1Y--1POWDER634A 233B C---------AM-4000 NOTIFIER1--F1--1-3-
1GF-HALLWAY 4NN----1Y--1POWDER634A 233B C----------2--F1----3-
1GF0101------------------------------------
1GF*001------------------------------------
1GF*002------------------------------------
1GF0119------------------------------------
1GF0108STORAGENN----------------------2--F-------
1FF0203OFFICENN----------------------1-F--------
1FF0204OFFICENN----------------------1-F--------
1FF0205COMM RM-----------------------------------
1FF0206OFFICENN----------------------1-F--------
1FF0207OFFICENN----------------------1-F--------
1FF0208OFFICENN----------------------1-F--------
1FF-HALLWAY 1NN1120YN----1POWDER634A 233B C----------1-F-2--1-1-
1FF0202BEDROOMNN160NN------------------2-F--------
1FF0201JANITOR CLOSETNN1120YN-----------------------------
1FF0200TOILETYN----------------------1-F------1-
1FF0209BEDROOMNN160NN------------------1-F--------
1FF-STAIRWAY 1NN160NN---------------------------11 10 mA MAGN. RES. CURR. BR.
1FF0210BEDROOMNN160NN------------------1-F--------
1FF0219BEDROOMNN160NN------------------1-F--------
1FF0211BEDROOMNN160NN------------------1-F--------
1FF0212TOILETYN----------------------2-F------3-
1FF0218BEDROOMNN160NN------------------1-F--------
1FF0217BEDROOMNN160NN------------------1-F--------
1FF0213LAUNDRYNN160NN------------------1-F--------
1FF0216BEDROOMNN160NN------------------1-F--------
1FF0215BEDROOMNN160NN------------------1-F--------
1FF0214LOUNGENN160NN------------------1-F--------
1FF-ENTRYNN----1Y-------------------------1-
1FF-HALLWAY 2NN----1N--3POWDER634A 233B C----------3-F2---1-4-
1SF-SAIRWAY 1NN160NN---------------------------21 10 mA MAGN. RES. CURR. BR.
1SF0314LOUNGENN160NN------------------1--F-------
1SF0316BEDROOMNN160NN------------------1--F-------
1SF0313LAUNDRYNN160NN------------------1--F-------
1SF0312TOILETYN----------------------2--F-----3-
1SF0317BEDROOMNN160NN------------------1--F-------
1SF0318BEDROOMNN160NN------------------1--F-------
1SF0311BEDROOMNN160NN------------------1--F-------
1SF0319BEDROOMNN160NN------------------1--F-------
1SF0310BEDROOMNN160NN------------------1--F-------
1SF0300TOILETYN----------------------1--F-----1-
1SF0309BEDROOMNN160NN------------------1--F-------
1SF0301JANITOR CLOSETNN---------------------------------
1SF0302BEDROOMNN160NN------------------1--F-------
1SF0308BEDROOMNN160NN------------------1--F-------
1SF0306BEDROOMNN160NN------------------1--F-------
1SF-HALLWAY 1NN----1N--2POWDER634A 233B C----------3--F2--1-5-
1SF-ENTRYNN----1Y-------------------------1-
1SF0303BEDROOMNN160NN------------------1--F-------
1SF0304BEDROOMNN160NN------------------2--F-------
1SF0305COMM RM-----------------------------------
1SF0307BEDROOMNN160NN------------------1--F-------
1SF0315------------------------------------
1SF315A------------------------------------
2GF0020MECH RMYN--------1POWDER634A 233B C----------1--F-------
2GF0018BREAK RMYN----------------------2--F-----2-
2GF-ENTRY 1YN----1Y--1POWDER634A 233B C----------1--F1----1-
2GF0017TOILETYN----------------------2--F-----1-
2GF0016TOILETYN----------------------1--F-----1-
2GF0011MEDICAL RMYN--------1POWDER634A 233B C----------21-F-----1-
2GF0015MEDICAL RMYN----------------------1--F-----1-
2GF0014STORAGEYN1120NN------------------1--F-----1-
2GF-VESTIBULEYN----------------------11-F-----1-
2GF0009RADIOLOGYYN----------------------21-F-----2-
2GF0010KENNELYN----------------------1--F-------
2GF0013SURGERY RMYN----------------------4--F-----1-
2GF0012SURGERY RMYN----1N--1POWDER634A 233B C----------4--F1----1-
2GF0007OFFICEYN----------------------21-F-----1-
2GF0006OFFICEYN----------------------11-F-----1-
2GF0005COPY RMYN--------1POWDER634A 233B C----------1--F1--1---
2GF0002RECEPTIONYN----1Y----------------31-F-----3-
2GF-ENTRY 2YN----1Y--1POWDER634A 233B C---------AM 2000----1----1-
2GF0001TOILETYN----------------------1--F-----1-
2GF0004MEDICAL RMYN----------------------1--F-----2-
2GF0003MEDICAL RMYN----------------------1--F-----2-
2GF-HALLWAYYN--------1POWDER634A 233B C----------64-F1--1-2EVACUATION PLAN
2GF*001MECH RMNN--------2POWDER634A 233B C---------------------
2GF-BLDG EXTERIOR----------------------------122---THE PULL STATION IS A SHUT OFF SWITCH
3GF*002JANITOR CLOSETNN---------------------------------
3GF*004FITNESS RMNN-------------------------------1-
3GF*001FITNESS RMYN-------------------------------1-
3GF-ENTRYNN----1N--1DRY CHEM230BC-------------------1-
3GF*003MECH RM-----------------------------------
7GF0003OFFICENN----------------------1--F-----2-
7GF0004OFFICENN----------------------1--F-----2-
7GF0005EMPTYNN----------------------11-F------
7GF0017COMM RMNN----------------------11-F-----1-
7GF0006OFFICENN----------------------11-F-----1-
7GF0016OFFICENN----------------------11-F-----2-
7GF0007TOILETNN-------------------------------1-
7GF0009TOILETNN-------------------------------2-
7GF0011OFFICENN----------------------11-F-----1-
7GF0015OFFICENN----------------------31-F-----1-
7GF0013OFFICENN----------------------1--F-----2-
7GF-ENTRYYN----1Y--------------------1-1--1-
7GF-HALLWAYYN----1Y--2POWDER634A 233B C---------AM 200033-F2--1-5EVACUATION PLAN
7---------1Y-------------------------1-
7GF0018MECH RMNN--------1POWDER634A 233B C-------------------2-
7GF-BLDG EXTERIOR----------------------------1--1--THE PULL STATION IS A SHUT OFF SWITCH
8GF0010OFFICENN----------------------11-F-------
8GF0008OFFICENN----------------------11-F-------
8GF0011TOILETNN-------------------------------1-
8GF011ATOILETNN---------------------------------
8GF0007OFFICENN----------------------11-F-------
8GF-HALLWAY 1YN----------------------11-F1--1-1EVACUATION PLAN
8GF0017OFFICENN----------------------1--F-------
8GF0006OFFICENN----------------------1--F-------
8GF0018OFFICENN----------------------1--F-------
8GF0004OFFICENN----------------------11-F-------
8GF0019OFFICENN----------------------11-F-------
8GF0003OFFICENN----------------------1--F-------
8GF-ENTRYYN----1Y----------------11-F1----3-
8GF-HALLWAY 2YN--------2POWDER634A 233B C----------11-F1--2-4EVACUATION PLAN
8GF0020EMPTYNN---------------------------------
8GF020ACOMM RMNN--------1POWDER634A 233B C---------------------
8GF0021OFFICENN----1Y----------------1--F1------
8GF0001CONFERENCE RMNN----1Y--1POWDER634A 233B C---------AM 20001--F1----1-
8FF0104OFFICENN----------------------1--F--1----
8FF0105OFFICENN----------------------1--F--1----
8FF0103OFFICENN----------------------1--F--1--1-
8FF0106TOILETNN----------------------------1----
8FF0102OFFICENN----------------------1--F--1----
8FF0112OFFICENN----------------------1--F--1--1-
8FF0101HALLWAYNN----1Y--2POWDER634A 233B C----------32-F2-12-2-
8GF-BLDG EXTERIOR-----------------------------1-----
9GF-ENTRYYN----1Y--------1-W----AM-2000 NOTIFIER1--F1----1-
9GF0026OFFICEYN----------------------11-F-----1-
9GF0002CONFERENCE RMYN----------------------31-F---1-12 SMOCK DETECTOR IN AIR DUCTS
9GF0006OFFICEYN----------------------11-F-----1-
9GF0004COMM RMYN----------------------11-F-----1-
9GF0005OFFICEYN----------------------11-F-----1-
9GF0008TOILETYN-----------------------------1-1-
9GF0010OFFICEYN----------------------11-F-----1-
9GF0019TELECOM RMNN--------1POWDER634A 233B C----------2-2F-----1-
9GF0020MECH RMNN----------------------1--F-----1-
9GF0018STORAGEYN----------------------1--F-------
9GF-HALLWAY 2YN----1Y----------------1--F1--1-1-
9GF-HALLWAY 1YN--------2POWDER634A 233B C----------22-F-----2-
9GF0011TOILETYN-----------------------------1-1-
9GF0016OFFICEYN----------------------11-F-----1-
9GF0012OFFICEYN----------------------21-F-----2-
9GF0014OFFICEYN----------------------21-F-----2-
9GF0025LABYN----1Y--1POWDER634A 233B C----------21-F-----3-
9GF-HALLWAY 3YN----1N--1POWDER634A 233B C----------11-F---1-1-
9GF0007EMPTYNN----------------------1--F-----1-
9GF-BOILER RMNN----------------------1--F1--1-1-
9GF0003STORAGENN----------------------1--F-------
9GF-BLDG EXTERIOR----------------------------2--1--PULL STATIONS ARE SHUT OFF SWITCHES
10GF0034CONFERENCE RMYY----1N----------------13-F,H----42
10GF0032COMPUTER RMYY----1N--1POWDER634A 233B C----------37-F,H----61-
10GF0030OFFICEYY----1N--1POWDER634A 233B C----------28-F,H1--1-1-
10GF-ENTRY 1YY----1N--2POWDER634A 233B C----------121F,H1--1-1-
10GF122AOFFICEYN----------------------1--F-------
10GF0122OFFICEYN----------------------1--F-------
10GF0121CONFERENCE RMYN----------------------1--F-------
10GF0118OFFICEYN----------------------1--F-------
10GF-VESTIBULE 1YN----1Y--1POWDER634A 233B C---------LCD-6000 NOTIFIER2--F1----1-
10GF0120CALL CENTERYY1120YY2Y--1POWDER634A 233B C----------4--F---1126-
10GF-HALLWAY 1YY----------------------1--F------PART OF THE FLOOR IS RAISED - EVACUATION PLAN
10GF-HALLWAY 2YN--------2POWDER634A 233B C----------1--F-----1EVACUATION PLAN
10GF0112OFFICEYN----------------------2--F---1-1-
10GF0125COMM RMYN----------------------2--F2-----ONE PULL STATION IS A SHUT OFF SWITCH
10GF*002TOILETYN----------------------1--F-------
10GF-HALLWAY 3YN----1Y--2POWDER634A 233B C----------2--F1--1-1EVACUATION PLAN
10GF*003TOILETYN----------------------1--F-----1-
10GF-HALLWAY 4YN-------------------------------1-
10GF0113OFFICEYN----------------------1--F-----1-
10GF0104OFFICEYN----------------------1--F-----1-
10GF-HALLWAY 5YN-------------------------------1-
10GF0105OFFICEYY----1N----------------1-3F,H-----2-
10GF105AOFFICEYY----------------------1-3F,H-----1-
10GF106AOFFICEYY----------------------1-3F,H-------
10GF0106OFFICEYY----------------------1-4F,H-----1-
10GF-HALLWAY 6YY--------1POWDER634A 233B C----------3-4F,H---1-1-
10GF-HALLWAY 7YY----------------------1-3F,H---1-2-
10GF0109OFFICEYY----------------------1--F-------
10GF0108OFFICEYY----------------------1--F-------
10GF108ASTORAGEYY----------------------1--F-----1-
10GF0101CALL CENTERYY----1N--2POWDER634A 233B C----------6-12F,H1--1104-
10GF0100CALL CENTERYY----1N----------------4-19F,H1--142-
10GF0102MECH RMNN----1N-------------------------1-
10GF*001SIPR-----------------------------------
10GF-ELECTRICAL RM-----------------------------------
10GF0126MECH RM-----------------------------------
10GF-BLDG EXTERIOR----------------------------2--1--PULL STATIONS ARE 2 SHUT OFF SWITCHES AND AN ALARM LEVER
23GF*001SHOPNN----1Y--3POWDER634A 233B C--15-W----AM-1000 NOTIFIER6--F2--1-3-
23--------------------------------------
23GF*006TOILETYN-------------------------------1-
23GF*005STORAGENN--------------1-W-----1--F-------
23GF*003OFFICENN--------------2-W-----1--F-----1-
23GF*002STORAGENN--------------2-W-----1--F-------
23---------------------------1--T-------
23GF*007MECH RMNN---------------------------------
23GF*004ELECTRICAL RM-----------------------------------
23FF*M01OFFICENN--------------2-W-----1--F-------
23GF-BLDG EXTERIOR----------------------------1111--THE PULL STATIONS IS A SHUT OFF SWITCH
24GF01BOILER RMNN--------1POWDER634A 233B C-------------------1-
24GF03TOILETNN-------------------------------1-
24GF02PUMP RMNN1120NN-----------------AM-1224 NOTIFIER2--F-----1-
24FF04EMPTYNN-------------------------------1-
24FF05EMPTYNN-------------------------------1-
24ATTIC06EMPTYNN-------------------------------1-
24ATTIC07EMPTYNN---------------------------------
24--STAIRWAYNN-------------------------------3-
24GF-BLDG EXTERIOR----------1CO2-----------------11----
28GF*006STORAGENN---------------------------------
28GF*005STORAGENN--------1POWDER655A 233B C---------------------
28GF*004STORAGENN---------------------------------
28GF*003STORAGENN---------------------------------
28GF*002STORAGENN---------------------------------
28GF*001STORAGENN--------1POWDER634A 233B C---------------------
28GF-BLDG EXTERIOR------------------------------1----
36GF*005STORAGEYY----------------------112F-----1-
36GF*006STORAGEYY--------1POWDER634A 233B C----------112F-----1-
36GF0044CALL CENTERYY----1Y--3POWDER634A 233B C----------51617F1--1-6CENTRALE FA IN BLDG 10
36---------1N-------------------------1-
36GF*002OFFICEYY----------------------111F-----1-
36GF*001OFFICEYY----------------------11-F-----1-
36GF*003TOILETYN----1N-------------------------1-
36GF*004TOILETYN----1N-------------------------1-
36GF-ENTRYYN----1Y----------------11-F1--1-1NR 1 RELASE BUTTON EXTERNAL OF THE BLDG
36GF0040SECURE AREA-----------------------------------
41GF01COMM RMNY2120YY1Y--1CO25113B--8-D----system 5005-4F3----22 PULL STATIONS ARE SHUT OFF SWITCHES
41---------------------------4--T-------
41GF02BATTERY RMNN1120YY----------1-D-----1--F-------
41---------------------------1--T-------
41GF03SPRINKLER RMNN1120YY-----------------------------
41GF-BLDG EXTERIOR-------------------------------1---
26GF001OFFICEYN----------------------11-F-----1-
26GF002TOILETYN-------------------------F-------
26GF003MECH ROOMNN---------------------AM 20001--F1------
26GF004OPEN BAYNN----1Y--2POWDER634A 233B C----------2--F2--1-2-
26GF005RETAIL SPACEYN----------------------21-F-----1-
26GF006COMM ROOMNN1123NN------------------1--F-----1-
26FF101OFFICEYN----------------------21-F-----1-
26FF102CONFERENCEYN----------------------11-F---1-1-
26GF-BLDG EXTERIOR-------------------------------1---
4GF001GUARDNN--------1POWDER634A 233B C---------------------
27GF001ENTRYYN---------------------------1-
27GF002OFFICEYN---------------------------1-
27GF003OFFICEYN--------1POWDER634A 233B C-------------------1-
27GF004OFFICEYN--------1POWDER634A 233B C-------------------1-
27GF-CANILE----------2POWDER634A 233B C---------------------
28GF-STORAGE----------3POWDER634A 233B C---------------------
33GF-SUBSTATION----------1POWDER634A 233B C-------------------1-
34GF-SUBSTATION----------1POWDER634A 233B C-------------------1-
38GF-SUBSTATION----------2POWDER634A 233B C-------------------2-
42GF-SUBSTATION----------1POWDER634A 233B C-------------------1-
MAINGF-SUBSTATION----------1POWDER634A 233B C-------------------1-
ACP SIDE GATEGF-ROOM-----------------------------------
TOTALS394629--78--32---92748880505133936208

Gemmo Spa-PWS 3.5-Inventory &"Arial Black,Normale"&14&A

Gemmo Spa-PWS 3.5-Inventory &"Arial Black,Normale"&14&A

Pag. &P / &N

Pag. &P / &N