ATTACHMENT III
LIST OF DELIVERABLES
Item Ref. Deliverable Completion date Subm it To
Check Delive red 1 G-03 Hazardous products inventory list with safety data sheet 30 days CA COR
2 G-05 As-built drawings 170 days NTP COR
3 G-06 Digging Permit Request Minimum 15 days before starting the earthwork
COR
4 G-07 Hot Work Permit Request 10 days NTP COR
5 G-08 EMS briefing verification signed document 30 days CA COR
6 G-10 The Safety and Health Plan 30 days CA COR
7 G-11/A AT Level I Training for each employee Take the training within 30 days CA and provide the certificate within 60 days CA
COR
8 G-11/C iWATCH/iSALUTE Training for each employee 30 days CA and within 5 days after new employees commence contract performance
COR
9 G-11/D OPSEC Training for each employee 30 days after each report for duty COR
10 TP-2-02 Vapor Barrier - Submittal Submitted for approval 30 days
CA
COR
11 TP-2-03 Insulation - Submittal Submitted for approval 30 days
CA
COR
12 TP-2-04 Sublayer (Vapor Spread) - Submittal Submitted for approval 30 days
CA
COR
13 TP-2-05 Water Tightness Layer - Submittal Submitted for approval 30 days
CA
COR
14 TP-2-05 Raised Parts - Submittal Approved by the COR and the Fire Chief 3 weeks before starting the work
COR
15 TP-3-01 Wall Cover - Submittal Submitted for approval NLT 3 weeks prior to installation
COR
16 TP-3-02 Zinc Work Along The Hangar Wall - Submittal Submitted for approval NLT 3 weeks prior to installation
COR
17 TP-3-04 Weather Fillets With Seal Around Metal Frame - Submittal
Submitted for approval 30 days
CA
COR
18 TP-3-05 Rainwater Inlets - Submittal Submitted for approval 30 days
CA
COR
19 TP-3-06 Water Downspouts Of The Hangar - Submittal Submitted for approval 30 days
CA
COR
20 TP-3-07 Water Downspouts Of The Annexes - Submittal Submitted for approval 30 days
CA
COR
21 TP-3-08 Manhole - Submittal Submitted for approval 30 days
CA
COR
22 TP-3-09 The Lighting Above Entrance Doors - Submittal Submitted for approval NLT 3 weeks before installation
COR
Legend:
CA – Contract award NTP – Notice to Proceed