Text version
R-CH # O2D-17104-17 - REPAIR ROOF # 20019
LIST OF DELIVERABLES
Item Ref. Deliverable Completion date Sub.
To
Check Deliv.
1 G-04 Scheduling of work Max 30 days after CA COR
2 G-05 As-built drawings After completion of the project and before submitting the final bill.
COR
3 G-06 Digging Permit Request Min 15 days before starting the earthwork COR
4 G-07 Hot Work Permit Request 7 days prior to starting the work COR
5 G-11 Employee information for installation access registration
15 days NTP and min 10 days before a new employee commence contract performance
COR
6 G-11 iWATCH/iSALUTE Training 30 days CA and within 5 days after new employees commence contract performance
COR
7 TP-2-01 Disposal certificate after old roof disposal After roof disposal COR
8 TP-3-01 Substrate - Submittal Submitted for approval 30 days after CA COR
9 TP-3-02 High Performance Overlay - Submittal Submitted for approval 30 days after CA COR
10 TP-3-02 Mortar for repair of concrete - Submittal Submitted for approval 30 days after CA COR
11 TP-3-02 Anti-carbonation of concrete - Submittal Submitted for approval 30 days after CA COR
12 TP-3-02 Two-component adherence primer coating (PPPU primer)
Submitted for approval 30 days after CA COR
13 TP-3-02 Self-cleaning elastic covering - Submittal Submitted for approval 30 days after CA COR
14 TP-4-01 Vapor barrier - Submittal Submitted for approval 30 days after CA COR
15 TP-4-01 Sloped insulating light weight concrete - Submittal
Submitted for approval 30 days after CA COR
16 TP-4-01 Certificate of certified firm for sloped insulating light weight concrete installation - Submittal
Submitted for approval 30 days after CA COR
17 TP-5-01 Soprastick SI (or equal) - Submittal Submitted for approval 30 days after CA COR
18 TP-5-01 Sopralene Techno 4 AF CLFR (or equal)- Submittal
Submitted for approval 30 days after CA COR
19 TP-6-01 Upstands - Submittal Submitted for approval 30 days after CA COR
20 TP-6-02 and special profiles membranes - Submittal Submitted for approval 30 days after CA COR
21 TP-7-01 PVC pipes - Submittal Submitted for approval 30 days after CA COR
22 TP-7-03 Hinged collar for water downspouts supports
- Submittal
Submitted for approval 30 days after CA COR
23 TP-7-04 Tail for rainwater shoe - Submittal Submitted for approval 30 days after CA COR
Legend: