A02WISSCPlans_Part7.pdf
PDF 10 MB Posted
- Attached to
- WELDON SPRING Federal contract opportunity
- Solicitation number
- W912P9-19-R-0022_
About this file
WELDON SPRINGS PLANS 7 OF 8
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A02WISSCPlans_Part3.pdf | ||
| A02DOEInterpretiveCenterAdvSpecs.pdf | ||
| A02WISSCPlans_Part4.pdf | ||
| A02WISSCPlans_Part5.pdf | ||
| A22W912P919R0022.pdf | ||
| A02WISSCPlans_Part1.pdf | ||
| A02WISSCPlans_Part6.pdf | ||
| A02WISSCPlans_Part8.pdf | ||
| A02WISSCPlans_Part2.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
J
J
J
J
M
J
H G F E
6.8
9.5
F.3 E.1 D.2E.8I
CLASSROOM 4
CLASSROOM
TABLE AND CHAIR
STORAGE
137A
CLASSROOM 3
INTERPRETIVE
PROGRAM
STORAGE AND
WORK ROOM
CLASSROOM 2
ENTRANCE/ASSEMBLY
AREA
VESTIBULE
CLASSROOM
TABLE AND CHAIR
STORAGE
141A
CLASSROOM 1
141 FRONT DESK
ADMINISTRATIVE
RECORD/REFERENCE
AREA
OFFICE
AUDITORIUM
OFFICE CORR.
WOMEN'S TOILET
MEN'S TOILET
TABLE AND CHAIR
STORAGE
TABLE AND CHAIR
STORAGE
CORRIDOR
P1B
FACP
GA-B
GA GA
GA-B
GAGAGAGA
GA-B
GA GA
GA-B
GA-B
GA GA
GA-B
GAGAGAGA
GA-B
GA GA
GA-B
GA-B
GA GA
GA-B
GAGAGAGA
GA-B
GA GA
GA-B
GA-B
GA GA
GA-B
GAGAGAGA
GA-B
GA GA
GA-B
GB
GB
GB GB GB GB
GBGBGBGB
DA DA DA DA DA
DA DA DA DA DA
DA DA DA DA DA
DA DA DA DA DA
DA
DA
DA
DA
DA
DA
DA
DA
DA
DA
DA
DA
TA
LA
LA
LA
LA
DA DA DA DA DA
GA GA GA
GAGAGA
GB-B
GB
GB
GB-B
DD
DD-B
DD
DD-B DD DD-B
DC
DD
DD-B
DD
DD-B
DD
DD-B
GF GF GF
GE GE GE
GE GE GE
LK LK
LH-4B LH-4 LH-4 LH-4B LH-4DB DB DB DB
DB DB DB DB
DB DB DB DB
DB DB DB DB
SB SB SB SB SB SB SB SB
SB SB SB SB SB SB SB SB
LE
LE-B
LE
LE
LE
LE-B
LE
LE
LE
LE-B
LE
LE-B
LE
LE
LE
LE-B
LE
LE
LE
LE-B
LE
LE-B
LE
LE
LE
LE-B
LE
LE
LE
LE-B
LB
LB
LB
LB
LC-8
LC-8
LC-14
LH-6 LH-6B LH-6 LH-6 LJ-4 LJ-4
LJ-8
SA SA SA SA SA SA SA SA SASA
LF LF
LF
LF
LFLF
LG
LG
L1A- 1
L1A- 3
L1A- 5
L1A- 7
L1A- 9
L1A- 11
LP
LP
L1A- 13
SEE E-202 FOR
CONTINUATION
LF
L1A- 17
LM-4
TB
TB
TB
TB
TB
TB
TB
TB
TB
TB
TB
TB
TB
TB
TB
TB
TA
TA
TA
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1 1
3 3 3 3 3
3 3 3 3
3 3 3 3
3 3 3 3 3
33333
5 5 5 5
5 5 5 5
5 5 5 5 5
7 7 7 7 7
7 7 7 7
15 15 15 15 15 15
9 9 9 9 9
9 9 9 9
9 9
9 9 9
9 9 9 9
11 11 11 11
11111111
11 11 11 11
1111111111
11 11 11 11 11
17 17
17 17 17
13 13 13
131313
13 13 13
15 15 15
151515
15 15
LD
LD
LD
LD
LD
SE SE SE SE SE SE SE SE SE SE SE SE
SE
SE
SE
SE
SE
SE
SE
SD
SD
SD
SD
SD
L1A- 16
L1A- 18
SEE E-202 FOR
CONTINUATION
10'-6" 8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"
IN-GROUND LIGHTS (TYP.)
LG
LG
LG
LG
LG
LG
LG
LG
22 22 22 22 22 22 22 22 22 22
8'-6"
SEE E-202 FOR
CONTINUATION
X
X
X
X
X
X
X
X
X
X
F
F.3 E.8
AA AA AAAA
LS
LS
LS (DOWN COLUMN)
LS (DOWN COLUMN)
F
F.3
LR
LQLQ
DD
L1A- 26
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-201
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
R .H
A L T
E M
A N
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S
A
IN
T C
H A
R L
E S
M
IS
S
O U
R I
E L E
C T
R
IC
A L L
IG
H
T
IN
G P
L A
N A
R E
A A
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
AREA
A
KEY PLAN - AREA 'A'
Plan North
TrueNorth
SCALE: 1/8" = 1'-0"1
ELECTRICAL LIGHTING PLAN AREA A
GENERAL NOTES E-201
1 REFER TO LIGHTING FIXTURE SCHEDULE FOR FIXTURE INFORMATION.
2 PROVIDE A COMPLETE LIGHTING CONTROL SYSTEM AS DESCRIBED ON
DRAWINGS AND IN SPECIFICATIONS. REFER TO LIGHTING CONTROL SCHEDULE
FOR SYSTEM CONCEPT AND FUNCTIONALITY.
3 COORDINATE PLACEMENT OF OCCUPANCY SENSORS WITH MILLWORK,
FURNITURE, EQUIPMENT, OR OTHER POTENTIAL OBSTRUCTIONS TO MOTION
DETECTION COVERAGE INSTALLED BY OTHERS.
4 COORDINATE PLACEMENT OF WALL SWITCH OCCUPANCY SENSORS WITH
ACTUAL INSTALLED DOOR SWINGS.
5 SEE LIGHTING CONTROL DRAWINGS E-203 AND E-204 FOR CONTROLS
COMPONENTS.
6 CONNECT UNSWITCHED EXIT SIGN LIGHTING CIRCUITS TO PANEL LIA. CIRCUIT
RUNS NOT SHOWN ON FLOORPLANS FOR READIBILITY.
KEYED NOTES - E-201
1 ROUTE CIRCUIT VIA LIGHTING CONTACTOR LOCATED IN THE ELECTRICAL ROOM.
ALSO SEE SITE LIGHTING CONTROL DETAIL, DRAWING E-803.
2 JUNCTION BOX TO DENOTE WIRING CONNECTIONS TO CONTINUOUS STRAND OF
LED TAPE-LIGHTING.
3 SEE DETAILS 4/A641, 5/A641, AND 6/A641 FOR CASEWORK DETAILS AND
TAPELIGHTING LOCATIONS.
4 LIGHTING CONTROLS FOR EXHIBIT HALL AND FRONT DESK OVERHEAD LIGHTING.
SEE FLOORPLAN AND LIGHTING CONTROLS DRAWING.
5 PROVIDE POWER TO LED TAPELIGHTING DRIVERS. EXTEND POWER TO ALL
TAPELIGHTING FEATURES AT THE FRONT DESK CASEWORK, TAPELIGHTING AT
THE ANGLED OVERHEAD FEATURE, AND CAN LIGHTS LOCATED IN THE
OVERHEAD ANGLED FEATURE . PROVIDE SWITCHING AS FOLLOWS: ON DIMMER
SWITCH TO CONTROL ALL TAPELIGHTING, ONE DIMMER SWITCH FOR CAN
LIGHTS.
SYMBOL
8'4' 16'0
SCALE: 1/8"=1'-0"
SCALE: 1/4" = 1'-0"2
FRONT DESK CEILING ELEMENT
SCALE: 1/4" = 1'-0"3
FRONT DESK - TAPELIGHTING
M
M
D C B
6.8
9.5
D.2 C.5 A
OPEN OFFICE
SMALL
TELECONF. RM
116 SMALL
TELECONF. RM
GARAGE
WOMEN'S
LOCKER RM
LAB
BREAK ROOM
CORRIDOR
DOCUMENT
STORAGE
VESTIBULE
111OFFICE CORR.
OFFICE
OFFICE
SMALL
CONFERENCE
ROOM
A/V 110A
MDP
P1A
L1A
P1B
LK LK
OFFICE
LK LK LK LK
GD
GD
GD GD
GD
GD
GD
GD-B
GD
GD
GD-B
GD
GD
GD
GD
GD
GD-B
GD
GD
GD-B
GA-B
GA GA
GA-B
DD DD
DDDD
DD DD
DDDD
LH-4B LH-4 LH-4LH-4BLH-4LH-4BLH-4LH-4LH-4BLH-4LH-4LH-4BLH-4
GA GA
GAGA
GA
GA-B
GA
GC GC
DFDF
DF
DF DF DF DF
DF
DEDE
DE
DE
DE
DE
LL-12 LL-12
LL-12E LL-12
LL-12 LL-12
LL-12E LL-12
LL-12 LL-12
LL-12E LL-12
LL-12 LL-12
LL-20
LL-20
TA
LN-8 LK LK LK
M1A
DPA
LM-8
LM-8
LM-8
LM-8
LM-8
LM-8
LFLF
LFLF
LM-4
LB
SA SA SA SA SA SA SA
LN-20
LN-20
LK
LN-16
L1A- 15
SEE E-201 FOR
CONTINUATION
L1A- 2
MECH
ELEC
A/V STOR.
129A
SERVER RM
L1A- 4
P1B- 8
L1A- 6
L1A- 8
LM-8 LM-8 LM-8
LM-8LM-8LM-8
LM-8
LM-8
LM-8
LM-8
L1A- 10
8 8
8 8
15 15 15 15 15 15
10 10 10
10 10
TB
TB
TB
TB
8 8
8 8
6 6
6 6 6 6
6 6 6 6
6 6
6 6
6 6 6
6 6
2 2
2 2
2 2
2 2
2 2
8 8 8
SE SE SE SE SE SE SE SE SE SE SE SE
SD
SD
SD
SD
L1A- 20
SEE E-201 FOR
CONTINUATION
L1A- 22 1
IN-GROUND LIGHTS (TYP.)
22 22 22 22 22 22 22
SF SF
SFSF
SF SF
SFSF
SF SF
SFSF
SF SF
L1A- 24
24 24
24 24
24 24
24 24
24 24
24 24
24 24
10'-6"
EM
EM
EM
EM
25252525252525252525252525
L1A- 25
SEE E-201 FOR
CONTINUATION
X
X
X
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-202
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
R .H
A L T
E M
A N
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S
A
IN
T C
H A
R L
E S
M
IS
S
O U
R I
E L E
C T
R
IC
A L L
IG
H
T
IN
G P
L A
N A
R E
A B
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
AREA
B
KEY PLAN - AREA 'B'
SCALE: 1/8" = 1'-0"1
ELECTRICAL LIGHTING PLAN AREA B
Plan North
TrueNorth
GENERAL NOTES E-202
1 REFER TO LIGHTING FIXTURE SCHEDULE FOR FIXTURE INFORMATION.
2 PROVIDE A COMPLETE LIGHTING CONTROL SYSTEM AS DESCRIBED ON
DRAWINGS AND IN SPECIFICATIONS. REFER TO LIGHTING CONTROL SCHEDULE
FOR SYSTEM CONCEPT AND FUNCTIONALITY.
3 COORDINATE PLACEMENT OF OCCUPANCY SENSORS WITH MILLWORK,
FURNITURE, EQUIPMENT, OR OTHER POTENTIAL OBSTRUCTIONS TO MOTION
DETECTION COVERAGE INSTALLED BY OTHERS.
4 COORDINATE PLACEMENT OF WALL SWITCH OCCUPANCY SENSORS WITH ACTUAL
INSTALLED DOOR SWINGS.
5 SEE LIGHTING CONTROL DRAWINGS E-203 AND E-204 FOR CONTROLS
COMPONENTS.
6 CONNECT UNSWITCHED EXIT SIGN LIGHTING CIRCUITS TO PANEL LIA. CIRCUIT
RUNS NOT SHOWN ON FLOORPLANS FOR READIBILITY.
KEYED NOTES - E-202
1 ROUTE CIRCUIT VIA LIGHTING CONTACTOR LOCATED IN THE ELECTRICAL ROOM.
ALSO SEE SITE LIGHTING CONTROL DETAIL, DRAWING E-803.
2 LIGHTING CONTROL DIGITAL TIMECLOCK FOR SITE LIGHTING. SEE 4/E-601.
SYMBOL
8'4' 16'0
SCALE: 1/8"=1'-0"
M
H G F E
6.8
9.5
F.3 E.1 D.2E.8I
FRONT DESK
VESTIBULE
ENTRANCE/ASSEMBLY
AREA
EXHIBIT HALL
133 AUDITORIUM
OFFICE
ADMINISTRATIVE
RECORD/REFERENCE
AREA
WOMEN'S TOILET
MEN'S TOILET
EXHIBIT HALL
CLASSROOM 4
CLASSROOM 3
CLASSROOM 2
INTERPRETIVE
PROGRAM
STORAGE AND
WORK ROOM
CLASSROOM 1
RD
PL
DM
WV
WV
EM
EM
EM
EM
WV
WV
PL
PL
PL
PL
FX
FX
FX
FX
CM
CM
CM
CM
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
WV
SA
SA
SA
SA
SA
WV
WV
TG
TG
SA
SA
TG
SEE E-204 FOR
CONTINUATION
EMPP
WV
SA
SA
WV
TG
TG
EM
PP
FX
RDRD EMRD
DMFX
RD
RD
RD
RD
RD
RD
RD
EM
RD
EM
RD
EM
RD
RD
EM
DMRD
EM
EM
1 2
1 1 2 1
ZONE 1: GE FIXTURES
ZONE 2: GF FIXTURES
ZONE 3: LP FIXTURE EAST
ZONE 4: LP FIXTURE WEST
ZONE 1: LA FIXTURE
ZONE 2: GA FIXTURES
ZONE 3: GA-B FIXTURES
ZONE 4: DA FIXTURES
ZONE 5: LB FIXTURES
ZONE 6: TRACK LIGHTING
ZONE 1: LA FIXTURE
ZONE 2: GA FIXTURES
ZONE 3: GA-B FIXTURES
ZONE 4: DA FIXTURES
ZONE 5: LB FIXTURES
ZONE 6: TRACK LIGHTING
ZONE 1: LA FIXTURE
ZONE 2: GA FIXTURES
ZONE 3: GA-B FIXTURES
ZONE 4: DA FIXTURES
ZONE 5: LB FIXTURES
ZONE 6: TRACK LIGHTING
ZONE 1: LA FIXTURE
ZONE 2: GA FIXTURES
ZONE 3: GA-B FIXTURES
ZONE 4: DA FIXTURES
ZONE 5: LB FIXTURES
ZONE 6: TRACK LIGHTING
EXHIBIT HALL
ZONE 1: DA FIXTURES
ZONE 2: DB FIXTURES
ZONE 3: LC-8 FIXTURE
ZONE 4: LD TAPELIGHTING
EXHIBIT HALL
ZONE 5: LE FIXTURES
ZONE 6: LE-B FIXTURES
EXHIBIT HALL
ZONE 10: LE FIXTURES
ZONE 11: LE-B FIXTURES
EXHIBIT HALL
ZONE 15: LE FIXTURES
ZONE 16: LE-B FIXTURES
EXHIBIT HALL
ZONE 7: DB FIXTURES
ZONE 8: LC-14 FIXTURE
ZONE 9: LD TAPELIGHTING
EXHIBIT HALL
ZONE 12: DB FIXTURES
ZONE 13: LC-8 FIXTURE
ZONE 14: LD TAPELIGHTING
RD
RD
RD1
RD1
NETWORK BRIDGE KIT, 8-PORT WITH POWER SUPPLY.
GRAPHICS WALLPOD CONTROL TOUCHPANEL, WITH POWER SUPPLY.
NETWORK GATEWAY KIT, WITH POWER SUPPLY.
POWER/RELAY PACK, SEMI AUTOMATIC-MANUAL ON.
1-CHANNEL ON/OFF TOGGLE.
PLUG LOAD CONTROL.
WALL SENSOR, DUAL TECHNOLOGY, SEMI-AUTOMATIC
WALL SENSOR, DUAL TECHNOLOGY, VACANCY
360 DEGREE, DUAL TECHNOLOGY, CEILING MOUNT OCCUPANCY SENSOR.
1-CHANNEL ON/OFF & RAISE/LOWER SWITCH.
RELAY MODULE W/ 0-10V DIMMING OUTPUT.
DM
PL
BR
FX
GW
RD
SA
TG
WS
WV
CAT5E CABLING
EMERGENCY RELAY MODULE W/ 0-10V DIMMING OUTPUT.EM
2-CHANNEL ON/OFF & RAISE/LOWER SWITCH.
4-CHANNEL ON/OFF & RAISE/LOWER SWITCH.
D2
D4
120 DEGREE WIDE VIEW CORNER MOUNT OCCUPANCY SENSOR.CM
POWER PACK/RELAY MODULE AUTOMATIC ON/OFF.PP
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-203
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
C h e c k e r
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S
A
IN
T C
H A
R L
E S
M
IS
S
O U
R I
E L E
C T
R
IC
A L L
IG
H
T
IN
G C
O N
T R
O L S
A R
E A
A
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
SCALE: 1/8" = 1'-0"1
ELECTRICAL LIGHTING CONTROLS AREA A
LIGHTING CONTROL SYMBOLS
GENERAL NOTES E-203
1 ONE RELAY IS NEEDED PER CIRCUIT TO BE CONTROLLED. RELAY/POWER PACK
PLACEMENT ON DRAWINGS IS FOR COUNTING PURPOSES ONLY. FINAL DESIGN
PLACEMENT IS UP TO THE DISCRETION OF THE CONTRACTOR.
2 BRIDGES AND SENSORS ON DRAWINGS WERE PLACED WITH INFORMATION
PROVIDED DURING DESIGN. ADDITIONAL BRIDGES AND/OR SENSORS MAY BE
REQUIRED DEPENDING ON FINAL PARTITION HEIGHTS, FURNITURE PLACEMENT,
AND EQUIPMENT HEIGHT/PLACEMENT.
3 THE LAYOUT OF THE NETWORK BACKBONE (BRIDGES AND GATEWAYS) HAS BEEN
PLACED IN A SEPARATE RISER DIAGRAM AND NOT ON THE ACTUAL LAYOUT. FINAL
PLACEMENT OF BRIDGE AND GATEWAY DEVICES SHALL BE AT THE
CONTRACTOR'S DISCRETION.
4 DEVICES HAVE RJ-45 FEMALE PORTS. MAKING CAT-5e CABLES WITH T568B MALE
TERMINATIONS IS REQUIRED.
KEYED NOTES - E-203
1 LINE VOLTAGE CONNECTION TO RELAY MODULE. SEE ELECTRICAL REFLECTED
CEILING PLANS FOR LINE VOLTAGE CIRCUIT NUMBERS. PROVIDE LINE VOLTAGE
CONNECTIONS FROM RELAY MODULE TO THE ZONE OF LIGHTING CONTROLLED.
2 LINE VOLTAGE CONNECTION TO EMERGENCY RELAY MODULE. SEE ELECTRICAL
REFLECTED CEILING PLANS FOR LINE VOLTAGE CIRCUIT NUMBERS. PROVIDE
LINE VOLTAGE CONNECTIONS FROM RELAY MODULE TO THE ZONE OF LIGHTING
CONTROLLED.
3 LINE VOLTAGE CONNECTION TO PLUG LOAD CONTROLLER. SEE ELECTRICAL
POWER FLOOR PLANS FOR LINE VOLTAGE CIRCUIT NUMBERS.
8'4' 16'0
SCALE: 1/8"=1'-0"
Plan North
TrueNorth
SYMBOL
M
M
D C B
6.8
9.5
D.2 C.5 A
SMALL
CONFERENCE
ROOM
LARGE CONF RM
OFFICE CORR.
103 VESTIBULE
OFFICE
OFFICE
OFFICE
OPEN OFFICE
SERVER RM
ELEC
A/V STOR.
129A
MECH
DOCUMENT
STORAGE
LAB
BREAK ROOM
DMDMDM
PLPLPL
RD RD RD
D2
RD
D2 D4
PL PL
RD RD
WV
RDRD
RD
RD
WV
TGTG
SASA
RD
WVWV
SASA
TGTG SASA
P1A
L1A
M1A
DPA
MDP
P1B
TG
SA
TGSA
TG SA
TG
SEE E-203 FOR
CONTINUATION
WV
SA
WV
SA
SA
WV
SA
WV
SA
TG
SA
TG
TG
SA
TG
TG
CM
SA
CM
CM
SA
WV
SA
WV
EM
1 1
EM
EM
1 1
3 1
ZONE 1: INNER (2) ROWS
ZONE 2: OUTER (2) ROWS
ZONE 3: TYPE LB LIGHTS
ZONE 4: TRACK LIGHTS
ZONE 1: LN-8, LN-16
ZONE 2: LK FIXTURES
ZONE 1: (3) ROWS LL-12
ZONE 2: (4) ROWS LL-12
EM
NETWORK BRIDGE KIT, 8-PORT WITH POWER SUPPLY.
GRAPHICS WALLPOD CONTROL TOUCHPANEL, WITH POWER SUPPLY.
NETWORK GATEWAY KIT, WITH POWER SUPPLY.
POWER/RELAY PACK, SEMI AUTOMATIC-MANUAL ON.
1-CHANNEL ON/OFF TOGGLE.
PLUG LOAD CONTROL.
WALL SENSOR, DUAL TECHNOLOGY, SEMI-AUTOMATIC
WALL SENSOR, DUAL TECHNOLOGY, VACANCY
360 DEGREE, DUAL TECHNOLOGY, CEILING MOUNT OCCUPANCY SENSOR.
1-CHANNEL ON/OFF & RAISE/LOWER SWITCH.
RELAY MODULE W/ 0-10V DIMMING OUTPUT.
DM
PL
BR
FX
GW
RD
SA
TG
WS
WV
CAT5E CABLING
EMERGENCY RELAY MODULE W/ 0-10V DIMMING OUTPUT.EM
2-CHANNEL ON/OFF & RAISE/LOWER SWITCH.
4-CHANNEL ON/OFF & RAISE/LOWER SWITCH.
D2
D4
120 DEGREE WIDE VIEW CORNER MOUNT OCCUPANCY SENSOR.CM
POWER PACK/RELAY MODULE AUTOMATIC ON/OFF.PP
BR
BR BR
GW
BR BR
BR
BR
BR
TOTAL OF (7) OUTPUT CONNECTIONS
TO ADDITIONAL BRIDGE HUBS OR ROOM
ZONES (TYPICAL FOR ALL HUBS).
LAPTOP BY
CONTRACTING
OFFICER FOR
PROGRAMMING.
BUILDING BMS
SYSTEM
SCHEMATIC DIAGRAM IS SHOWN FOR REFERENCE ONLY
AND IS MEANT FOR A GENERAL OVERIVEW OF NETWORKED
LIGHTING CONTROL. ACUITY BRANDS nLIGHT IS THE BASIS OF
DESIGN MANUFACTURER.
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-204
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
C h e c k e r
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S
A
IN
T C
H A
R L
E S
M
IS
S
O U
R I
E L E
C T
R
IC
A L L
IG
H
T
IN
G C
O N
T R
O L S
A R
E A
B
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
SCALE: 1/8" = 1'-0"1
ELECTRICAL LIGHTING CONTROLS AREA B LIGHTING CONTROL SYMBOLS
GENERAL NOTES E-204
1 ONE RELAY IS NEEDED PER CIRCUIT TO BE CONTROLLED. RELAY/POWER PACK PLACEMENT ON DRAWINGS IS FOR COUNTING PURPOSES ONLY. FINAL DESIGN PLACEMENT IS UP TO THE DISCRETION
OF THE CONTRACTOR.
2 BRIDGES AND SENSORS ON DRAWINGS WERE PLACED WITH INFORMATION PROVIDED DURING
DESIGN. ADDITIONAL BRIDGES AND/OR SENSORS MAY BE REQUIRED DEPENDING ON FINAL PARTITION
HEIGHTS, FURNITURE PLACEMENT, AND EQUIPMENT HEIGHT/PLACEMENT.
3 THE LAYOUT OF THE NETWORK BACKBONE (BRIDGES AND GATEWAYS) HAS BEEN PLACED IN A
SEPARATE RISER DIAGRAM AND NOT ON THE ACTUAL LAYOUT. FINAL PLACEMENT OF BRIDGE AND
GATEWAY DEVICES SHALL BE AT THE CONTRACTOR'S DISCRETION.
4 DEVICES HAVE RJ-45 FEMALE PORTS. MAKING CAT-5e CABLES WITH T568B MALE TERMINATIONS IS
REQUIRED.
KEYED NOTES - E-204
1 LINE VOLTAGE CONNECTION TO RELAY MODULE. SEE ELECTRICAL REFLECTED CEILING PLANS FOR LINE VOLTAGE CIRCUIT NUMBERS. PROVIDE LINE VOLTAGE CONNECTIONS FROM RELAY MODULE TO
THE ZONE OF LIGHTING CONTROLLED.
2 LINE VOLTAGE CONNECTION TO EMERGENCY RELAY MODULE. SEE ELECTRICAL REFLECTED CEILING PLANS FOR LINE VOLTAGE CIRCUIT NUMBERS. PROVIDE LINE VOLTAGE CONNECTIONS FROM RELAY
MODULE TO THE ZONE OF LIGHTING CONTROLLED.
3 LINE VOLTAGE CONNECTION TO PLUG LOAD CONTROLLER. SEE ELECTRICAL POWER FLOOR PLANS
FOR LINE VOLTAGE CIRCUIT NUMBERS.
4 OCCUPANCY/DAYLIGHT SENSOR FURNISHED AS AN INTEGRAL PART OF THE LIGHT FIXTURE.
NETWORKED LIGHTING CONTROL SYSTEM
GW
8'4' 16'0
SCALE: 1/8"=1'-0"
Plan North
TrueNorth
GFCI
GFCI
GFCI
GFCI
J48" J 48"
J 48"J 48"
GFCI
GFCI
GFCI
GFCI
GFCI
J
J
J
J
J
J
J
GFCI
J
H G F E
6.8
9.5
F.3 E.1E.8I
OFFICE
MEN'S TOILET
ADMINISTRATIVE
RECORD/REFERENCE
AREA
AUDITORIUM
EXHIBIT HALL
VESTIBULE
CLASSROOM 1
CLASSROOM 2
CLASSROOM 3
CLASSROOM 4
INTERPRETIVE
PROGRAM
STORAGE AND
WORK ROOM
CLASSROOM
TABLE AND CHAIR
STORAGE
141A
CLASSROOM
TABLE AND CHAIR
STORAGE
137A
TABLE AND CHAIR
STORAGE
CORRIDOR
FRONT DESK
TABLE AND CHAIR
STORAGE
JAN. CL.
134B
WINDOW SILL
PLANTER
WOMEN'S TOILET
ENTRANCE/ASSEMBLY
AREA
FACP
42"
42"
42"
OFFICE CORR.
42"
34" 34"
WP
WP
WP
WP
WP
42"
P1A- 1
P1A- 3,5
M1A- 34 M1A- 37
M1A- 33 M1A- 35
P1A- 11
P1A- 23
29 29
P1A- 29,31
P1A- 33,35
P1A- 41,43
P1A- 45,47
33 33
47 7 7 7
P1A- 7
P1A- 9
37 37
P1A- 37
P1A- 39
P1A- 49,51
49 51
P1A- 53
P1A- 13
15 15 15
P1A- 25,27252525
25 25 27 27
WP
P1A- 55
M1A- 1,3,5
M1A- 2,4,6
3#10,1#10G,3/4"C
3#10,1#10G,3/4"C
27 27 27 27
P1A- 19,21
21 21
15 15 17 17
17 17 17 17
P1A- 15,17
72"
72"
34"
1"C1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C1"C
1"C1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
1"C
P1A- 69
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-301
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
R .H
A L T
E M
A N
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S A
IN
T
C H
A R
L E
S M
IS
S
O U
R I
E L E
C T
R
IC
A L P
O W
E R
P L A
N A
R E
A A
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
AREA
A
KEY PLAN - AREA 'A'
SCALE: 1/8" = 1'-0"
ELECTRICAL POWER PLAN AREA A
KEYED NOTES - E-301
1 DUPLEX RECEPTACLE MOUNTED FLUSH IN CEILING TILE FOR CONNECTIONS TO
OVERHEAD PROJECTOR.
2 JUNCTION BOX FOR POWER CONNECTIONS TO ELECTRIC HAND DRYER.
3 PROVIDE POWER CONNECTION TO MOTORIZED WINDOW SHADES.
4 KEY PAD FOR CONTROL OF MOTORIZED SHADES. PROVIDE WIRING CONNECTIONS PER
SHADE MANUFACTURER'S INSTRUCTIONS.
5 TOUCHSCREEN CONTROL FOR MOTORIZED PARTITION. INSTALL CUSTOM
MANUFACTURER SUPPLIED JUNCTION BOX 42" AFF. AND PROVIDE WIRING
CONNECTIONS TO PARTITION DRIVE CONTROL BOX.
6 EXTERIOR WEATHERPROOF GFCI RECEPTACLE WITH IN-USE COVER. SEE
SPECIFICATIONS.
7 PROVIDE WIRING CONNECTIONS TO MOTORIZED PARTITION DRIVE CONTROL BOX PER
MANUFACTURER'S INSTRUCTIONS. FURNISH AND INSTALL A 30A/3P NON-FUSED
DISCONNECT ABOVE CEILING NEAR THE ACCESS PANEL.
8 MOUNT PRIVATE OFFICE RECEPTACLE AND DATA IN OPEN KNEESPACE, CLEAR OF
DESK SUPPORTS AND OBSTRUCTIONS. COORDINATE LOCATIONS WITH FURNITURE
LAYOUT.
9 PROVIDE WIRING CONNECTION TO AUTOMATIC DOORS.
10 OUTLET DEVICES SUCH AS RECEPTACLES AND COVERPLATES LOCATED IN THE EXHIBIT
HALL SHALL BE BLACK IN COLOR.
11 DATA OUTLET MOUNTED FLUSH IN CEILING TILE FOR CONNECTIONS TO OVERHEAD
PROJECTOR.
SYMBOL
Plan
North TrueN orth
GFCIGFCI
GFCI
GFCI
GFCIGFCI
G F
C I
GFCI
GFCI
GFCI
J
J
J
J
GFCI
J J
J48" J48"
J
J
J
J
M
J
J
J
J
M
D C B
6.8
9.5
D.2 C.5 A
LARGE CONF RM
SMALL
CONFERENCE
ROOM
OFFICE
MECH
OFFICE
A/V STOR.
129A
OFFICE CORR.
DOCUMENT
STORAGE
LAB
GARAGE
A/V 110A
ELEC
SERVER RM
WINDOW SILL
PLANTER
SMALL
TELECONF. RM
SMALL
TELECONF. RM
MEN'S TOILET
WOMEN'S TOILET
CORRIDOR
CORRIDOR
VESTIBULE
JAN. CL.
MEN'S TOILET
119A
MEN'S LOCKER
RM
WOMEN'S
LOCKER RM
WOMEN'S TOILET
118A
BREAK ROOM
SHOWER
118B
SHOWER
119B
MDP
L1A
P1A
T1
42"42"
42"
60"
P1B
FACP
36"
36"
42"42"
72"
M1A- 28
DPA
M1A
WP
WP
P1A- 2,4,6
OPEN OFFICE
P1A- 8,10,12
P1A- 16,18,20
P1A- 24,26,28
P1A- 32,34,36
P1A- 44
M1A- 32
48 48
P1A- 48
P1A- 40
40 40
P1A- 52
52 52
62 62
P1A- 56
P1A- 58
OFFICE
P1A- 60
42"
P1A- 64
P1A- 72
P1A- 66,68,70
70 68
P1A- 62
72"
72"
72"
63 63
63 63
P1A- 63,65
59 59
P1A- 59,61
P1A- 57
P1B- 10,12
10 10
12P1B- 2
P1B- 4
P1B- 6
60 58 56
P1A- 42
P1A- 54
M1A- 30
36"36"
18"
72"
72"
72"
36"
72" 65 65
61 6161
P1A- 46
50 50
P1A- 50
P1A- 67
P1A- 38
P1A- 30
P1A- 22
P1A- 14
1"C1"C
1"C1"C 1"C
P1B- 1,3 3#10
M1A- 39
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
M1A- 24
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-302
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
R .H
A L T
E M
A N
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S
A
IN
T C
H A
R L
E S
M
IS
S
O U
R I
E L E
C T
R
IC
A L P
O W
E R
P L A
N A
R E
A B
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
AREA
B
KEY PLAN - AREA 'B'
SCALE: 1/8" = 1'-0"1
ELECTRICAL POWER PLAN AREA B
Plan North
TrueNorth
KEYED NOTES - E-302
1 INSTALL A JUNCTION BOX WITH 1" CONDUIT INTO ACCESSIBLE CEILING SPACE FOR AUTO
DOOR PUSH PLATE. PUSH PLATE AND WIRING TO DOOR CONTROLLER FURNISHED AND
INSTALLED BY DOOR HARDWARE CONTRACTOR.
2 2"x1/4"x12" COPPER GROUND BUS BAR. J-STD-A-2002 COMPIANT WITH 1-1/2" INSULATED
STANDOFFS.
3 FURNISH AND INSTALL PLYWOOD BACKBOARDS FOR EQUIPMENT MOUNTING. SEE
SPECIFICATIONS.
4 PROVIDE POWER CONNECTION TO MOTORIZED WINDOW SHADES.
5 KEY PAD FOR CONTROL OF MOTORIZED SHADES. PROVIDE WIRING CONNECTIONS PER
SHADE MANUFACTURER'S INSTRUCTIONS.
6 MOUNT RECEPTACLES ON LADDER TRAY ABOVE SERVER CABINETS.
7 PROVIDE POWER CONNECTION TO MOTORIZED DOORS. PROVIDE WIRING AND
CONNECTIONS TO WALL MOUNTED CONTROLS.
8 IRRIGATION CONTROLLER FURNISHED BY LANDSCAPE ARCHITECT, 120V POWER BY
ELECTRICAL CONTRACTOR. FURNISH AN EMPTY 1" PVC UNDERGROUND CONDUIT TO
GRASS AREA OUTSIDE OF THE BUILDING.
9 EXTERIOR WEATHERPROOF GFCI RECEPTACLE WITH IN-USE COVER. SEE
SPECIFICATIONS.
10 JUNCTION BOX FOR 120V CONNECTION TO CUBICLE PARTITIONS. PROVIDE FURNITURE
FEED FLEXIBLE CONNECTION. (3) CIRCUITS PER GROUP OF CUBICLES. PROVIDE WIRING
CONNECTIONS TO CUBICLE RECEPTACLES PER MANUFACTURER'S INSTRUCTIONS.
11 COMBINATION STARTER/DISCONNECT SWITCHES FOR EXHAUST FANS EF-1 AND EF-2.
12 PROVIDE WIRING CONNECTION TO AUTOMATIC DOORS.
13 LIGHTING CONTROL DIGITAL TIMECLOCK FOR SITE LIGHTING. SEE 1/E-803.
14 INSTALL A FLUSH IN-FLOOR BOX WITH COVERPLATE AND APPROPRIATE FLOOR FLANGE
FOR FUTURE FURNITURE CONNECTIONS. PROVIDE TWO (2) 1" CONDUITS TO NEARS WALL
AND STUB UP IN ACCESSIBLE CEILING SPACE.
15 JUNCTION BOX FOR 120V CONNECTION TO CUBICLE PARTITIONS. PROVIDE FURNITURE
FEED FLEXIBLE CONNECTION. (1) CIRCUITS PER GROUP OF CUBICLES FOR ISOLATED
GROUND DUPLEX RECEPTACLES. PROVIDE WIRING CONNECTIONS TO CUBICLE
RECEPTACLES PER MANUFACTURER'S INSTRUCTIONS.
16 MOUNT PRIVATE OFFICE RECEPTACLE AND DATA IN OPEN KNEESPACE, CLEAR OF DESK
SUPPORTS AND OBSTRUCTIONS. COORDINATE LOCATIONS WITH FURNITURE LAYOUT.
17 DUPLEX RECEPTACLE FOR FIRE PROTECTION PRE-ACTION SYSTEM AIR COMPRESSOR.
COORDINATE EXACT LOCATION WITH FIRE PROTECTION CONTRACTOR.
18 FIXED FURNITURE DATA OUTLETS SHOWN FOR REFERENCE ONLY. PROVIDE WIRING
CONNECTIONS TO DATA OUTLETS FURNISHED AS PART OF THE CUBICLE PARTITIONS
PER MANUFACTURER'S INSTRUCTIONS.
SYMBOL
H G F E
6.8
9.5
F.3 E.1E.8I
MEN'S TOILET
ADMINISTRATIVE
RECORD/REFERENCE
AREA
AUDITORIUM
EXHIBIT HALL
VESTIBULE
CLASSROOM 1
CLASSROOM 2
CLASSROOM 3
CLASSROOM 4
INTERPRETIVE
PROGRAM
STORAGE AND
WORK ROOM
CLASSROOM
TABLE AND CHAIR
STORAGE
141A
CLASSROOM
TABLE AND CHAIR
STORAGE
140A
CLASSROOM
TABLE AND CHAIR
STORAGE
138A
CLASSROOM
TABLE AND CHAIR
STORAGE
137A
TABLE AND CHAIR
STORAGE
CORRIDOR
FRONT DESK
TABLE AND CHAIR
STORAGE
FAMILY
RESTROOM
JAN. CL.
134B
WOMEN'S TOILET
ENTRANCE/ASSEMBLY
AREA
FACP
OFFICE CORR.
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
BS
2.1
BS
1.2
M1A- 7,9
M1A- 11,13
FCU
FCU
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-303
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
C h e c k e r
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S A
IN
T
C H
A R
L E
S M
IS
S
O U
R I
E L E
C T
R
IC
A L
H V
A C
C O
N N
E C
T
IO
N S
A R
E A
A
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
SCALE: 1/8" = 1'-0"
ELECTRICAL HVAC POWER PLAN AREA A 8'4' 16'0
SCALE: 1/8"=1'-0"
AREA
A
KEY PLAN - AREA 'A'
Plan
North TrueN orth
GENERAL NOTES E-303
1 SEE EQUIPMENT DATA SCHEDULE SHEET FOR ADDITIONAL CONNECTION
INFORMATION.
M
M
M
D C B
6.8
9.5
D.2 C.5 A
LARGE CONF RM
SMALL
CONFERENCE
ROOM
OFFICE
MECH
OFFICE
A/V STOR.
129A
OFFICE CORR.
DOCUMENT
STORAGE
LAB
GARAGE
A/V 110A
ELEC
SERVER RM
WINDOW SILL
PLANTER
SMALL
TELECONF. RM
SMALL
TELECONF. RM
MEN'S TOILET
WOMEN'S TOILET
CORRIDOR
CORRIDOR
VESTIBULE
JAN. CL.
MEN'S TOILET
119A
MEN'S LOCKER
RM
WOMEN'S
LOCKER RM
WOMEN'S TOILET
118A
BREAK ROOM
SHOWER
118B
SHOWER
119B
MDP
L1A
P1A
T1
P1B
FACP
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
DPA
M1A
FCU
FCU
FCU
FCU
FCU
17 BS
3.1
FCU
M1A- 12,14
GFWH
M1A- 23
P1B- 5,7
OPEN OFFICE
OFFICE
CP
M1A- 20
FCU
FCU
BS
3.2
M1A- 16,18
UH
FCU
M1A- 19,21
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-304
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
C h e c k e r
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S A
IN
T
C H
A R
L E
S M
IS
S
O U
R I
E L E
C T
R
IC
A L
H V
A C
C O
N N
E C
T
IO
N S
A R
E A
B
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
SCALE: 1/8" = 1'-0"
ELECTRICAL HVAC POWER PLAN AREA B 8'4' 16'0
SCALE: 1/8"=1'-0"
AREA
B
KEY PLAN - AREA 'B'
Plan
North TrueN orth
GENERAL NOTES E-304
1 SEE EQUIPMENT DATA SCHEDULE SHEET FOR ADDITIONAL CONNECTION INFORMATION.
S
V75
S
V75
S
V75
S
V75
S
V75
S
V15
S
V15
S
V75
S
V75
S
V75
S
V75
C R
C R
C R
CR
CR
CR
CR
C R
C R
C R
C R
C R
C R
C R
C R
C R
C R
C R
CR
F
F
F
S
V75
S
V75
S
V75
S
V75
S
V75
S
V75
CR
S
S
S
S
S
S
S
S
S
S
S
S
SU
SU
SU
SU
SU
SU
S
S
S
S
S
S
S
S
S
S S
SS
SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
F
DD
F
DD
F
DD F
DD
H G F E
6.8
9.5
F.3 E.1E.8I
OFFICE
OFFICE
MEN'S TOILET
ADMINISTRATIVE
RECORD/REFERENCE
AREA
AUDITORIUM
EXHIBIT HALL
VESTIBULE
CLASSROOM 1
CLASSROOM 2
CLASSROOM 3
CLASSROOM 4
INTERPRETIVE
PROGRAM
STORAGE AND
WORK ROOM
CLASSROOM
TABLE AND CHAIR
STORAGE
141A
CLASSROOM
TABLE AND CHAIR
STORAGE
140A
CLASSROOM
TABLE AND CHAIR
STORAGE
138A
CLASSROOM
TABLE AND CHAIR
STORAGE
137A
CORRIDOR
FRONT DESK
SERVER RM
FAMILY
RESTROOM
JAN. CL.
134B
WINDOW SILL
PLANTER
WOMEN'S TOILET
ENTRANCE/ASSEMBLY
AREA
P1B
FACP
OFFICE CORR.
CAM-B
CAM-B
CAM-C
CAM-D
CAM-D
CAM-C
CAM-A
CAM-E
CAM-A
CAMCAM
CAM-A
CAM-A
CAM-A
CAM-A CAM-A
DC
DC
DC
DC
DC
DC
DC
DC
EL
EL
EL
EL
EL
EL
EL
EL
REX
REX
REX
REX
REX
REX
REX
DC
REX
PH PH
PH
PH
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
PR2
PR2
PR2
PR2
WMR
WMR
WMR
WMR
WMR
VMS AMP
WM HM
WM
HM
WM
HM
WM
HM
WM
HM
DC
137B
138B
139A139B
140B
141B
129A
130B
M84
2 2
130A
DOAS-1
DOAS-2
SC
SC
SC
SC
TC
TC
TC
TC
TC
WAP
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-401
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
R .H
A L T
E M
A N
-0 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S A
IN
T
C H
A R
L E
S M
IS
S
O U
R I
E L E
C T
R
IC
A L S
Y S
T E
M S
P L A
N A
R E
A A
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
AREA
A
KEY PLAN - AREA 'A'
SCALE: 1/8" = 1'-0"
ELECTRICAL SYSTEMS PLAN AREA A
Plan
North TrueN orth
KEYED NOTES - E-401
1 FIRE ALARM SYSTEM REMOTE ANNUNCIATOR PANEL.
2 CARD READER IS PART OF THE DOOR MORTISE LOCK ASSEMBLY. SEE HARDWARE
SPECIFICATIONS 087100 FOR ADDITIONAL INFORMATION.
3 PROPOSED CAMERA VIEWING ANGLE.
SYMBOL
GENERAL NOTES E-401
1 PROVIDE A NEW ACCESS CONTROL SYSTEM CONSISTING OF ALL REQUIRED
EQUIPMENT, CONDUIT, BOXES, WIRING, HARDWARE, SUPPORTS, ACCESSORIES,
SOFTWARE, SYSTEM PROGRAMMING, ETC. AS NECESSARY FOR A COMPLETE
OPERATING SYSTEM THAT PROVIDES THE FUNCTIONAL INTENT INDICATED.
2 REFER TO SYSTEM RISERS SHEET E-702 FOR TELECOMMUNICATIONS AND FIRE
ALARM RISER DIAGRAMS.
3 REFER TO DOOR ACCESS WIRING DIAGRAM, DRAWING E-601 FOR ADDITIONAL
ACCESS CONTROL REQUIREMENTS.
4 REFER TO DETAILS SHEET E-602 FOR TELECOMMUNICATIONS DETAILS.
5 PROVIDE A NEW VIDEO SURVEILLANCE SYSTEM CONSISTING OF ALL REQUIRED
EQUIPMENT, CONDUIT, BOXES, WIRING, HARDWARE, SUPPORTS, ACCESSORIES,
SOFTWARE, SYSTEM PROGRAMMING, ETC. AS NECESSARY FOR A COMPLETE
OPERATING SYSTEM THAT PROVIDES THE FUNCTIONAL INTENT INDICATED.
6 PROVIDE A COMPLETE PERMANENT SYSTEM OF CABLING AND PATHWAYS FOR
VOICE, DATA COMMUNICATIONS, AND AUDIO/VISUAL SYSTEMS, INCLUDING CABLES,
CONDUITS, WIREWAYS, SUPPORT STRUCTURES, ENCLOSURES, CABINETS,
SPEAKERS, HARDWARE, AND OUTLETS.
7 PROVIDE A NEW AUTOMATIC ADDRESSIBLE FIRE ALARM DETECTION AND ALARM
SYSTEM. PROVIDE ALL COMPONENTS NECESSARY FOR A COMPLETE AND
OPERATIONAL SYSTEM.
F
F
F
V30
F
V75
S
V15
S
V15
F
V75
F
V75
S
V75
C R
C R
C R
F
SD
S
V75
S
V75
S
V75
S
V75
F
V75
C R
C R
C R
C R
C R
C R
CR
CR
CR
C R
CR
F
SS
F
WF
F
SS
F
SS
F S
V75
S
V15
S
V15
S
V15
S
V15
F
V15
F
V15
F
WF
F
SS
F
DD
M
D C B
6.8
9.5
D.2 C.5 A
LARGE CONF RM
SMALL
CONFERENCE
ROOM
OFFICE
MECH
OFFICE
OPEN OFFICE
A/V STOR.
129A
OFFICE CORR.
DOCUMENT
STORAGE
LAB
GARAGE
A/V 110A
ELEC
SERVER RM
WINDOW SILL
PLANTER
SMALL
TELECONF. RM
116 SMALL
TELECONF. RM
MEN'S TOILET
WOMEN'S TOILET
CORRIDOR
CORRIDOR
VESTIBULE
JAN. CL.
MEN'S TOILET
119A
MEN'S LOCKER
RM
WOMEN'S
LOCKER RM
WOMEN'S TOILET
118A
BREAK ROOM
SHOWER
118B
SHOWER
119B
MDP
L1A
P1A
T1
P1B
FACP
M1A
DPA
CAM-A
CAM-B
CAM-B
CAM-A
DC
DC
DC
DC
DC
DC
EL
EL
EL
EL
EL
EL
REX
REX
REX
REX
REX
REX
DC
DC
DC
PH
PH
PH
PH
PH
PH
PH
PH
PH
PH
PH
PH
PH
PH
PH
PH
PH
PH
PH PHPH
PH
PH
WAP
WAP
WAP
WAP
M55
M55
M55
M55
TVC
TVC
PM PM
VMS
AMP
DC PH PH
PH
PH
110A
111B
112A
113A
113B
112B
113C
114A
114B
125B
DOAS-2
D.2
ACP
NVR
P1B
NSW
NSW
UPS
UPS
PP
PP
PDU
PDU
RACK MOUNTED
EQUIPMENT.
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-402
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
R .H
A L T
E M
A N
-0 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S A
IN
T
C H
A R
L E
S M
IS
S
O U
R I
E L E
C T
R
IC
A L S
Y S
T E
M S
P L A
N A
R E
A B
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
AREA
B
KEY PLAN - AREA 'B'
SCALE: 1/8" = 1'-0"
ELECTRICAL SYSTEMS PLAN AREA B
Plan
North TrueN orth
KEYED NOTES - E-402
1 SERVER RACKS FURNISHED AND INSTALLED BY D.O.E.
2 CARD READER IS PART OF THE DOOR MORTISE LOCK ASSEMBLY. SEE HARDWARE
SPECIFICATIONS 087100 FOR ADDITIONAL INFORMATION.
3 FURNISH AND INSTALL LADDER TYPE CABLE TRAY MOUNTED ABOVE SERVER RACK
CABINETS.
4 PROPOSED CAMERA VIEWING ANGLE.
5 SMALL CONFERENCE ROOM MONITORS FURNISHED BY DOE CONTRACTING OFFICER.
SYMBOL
GENERAL NOTES E-402
1 PROVIDE A NEW ACCESS CONTROL SYSTEM CONSISTING OF ALL REQUIRED EQUIPMENT,
CONDUIT, BOXES, WIRING, HARDWARE, SUPPORTS, ACCESSORIES, SOFTWARE, SYSTEM
PROGRAMMING, ETC. AS NECESSARY FOR A COMPLETE OPERATING SYSTEM THAT
PROVIDES THE FUNCTIONAL INTENT INDICATED.
2 REFER TO SYSTEM RISERS SHEET E-702 FOR TELECOMMUNICATIONS AND FIRE ALARM
RISER DIAGRAMS.
3 REFER TO DOOR ACCESS WIRING DIAGRAM, DRAWING E-601 FOR ADDITIONAL ACCESS
CONTROL REQUIREMENTS.
4 REFER TO DETAILS SHEET E-602 FOR TELECOMMUNICATIONS DETAILS.
5 PROVIDE A NEW VIDEO SURVEILLANCE SYSTEM CONSISTING OF ALL REQUIRED EQUIPMENT,
CONDUIT, BOXES, WIRING, HARDWARE, SUPPORTS, ACCESSORIES, SOFTWARE, SYSTEM
PROGRAMMING, ETC. AS NECESSARY FOR A COMPLETE OPERATING SYSTEM THAT
PROVIDES THE FUNCTIONAL INTENT INDICATED.
6 PROVIDE A COMPLETE PERMANENT SYSTEM OF CABLING AND PATHWAYS FOR VOICE, DATA
COMMUNICATIONS, AND AUDIO/VISUAL SYSTEMS, INCLUDING CABLES, CONDUITS,
WIREWAYS, SUPPORT STRUCTURES, ENCLOSURES, CABINETS, SPEAKERS, HARDWARE,
AND OUTLETS.
7 PROVIDE A NEW AUTOMATIC ADDRESSIBLE FIRE ALARM DETECTION AND ALARM SYSTEM.
PROVIDE ALL COMPONENTS NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM.
SCALE: 1/4" = 1'-0"
SERVER ROOM - 128
GFCI
H G F
6.8
9.5
F.3 E.8I
MDP- 4
WP
DOAS
EF
CU
DNDN
DN
M1A- 25
MDP- 2
WP
M1A- 27
M1A- 29
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-501
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
R .H
A L T
E M
A N
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S A
IN
T
C H
A R
L E
S M
IS
S
O U
R I
E L E
C T
R
IC
A L R
O O
F P
L A
N A
R E
A A
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
SCALE: 1/8" = 1'-0"
ELECTRICAL ROOF PLAN AREA A
Plan
North TrueN orth
KEYED NOTES - E-501
1 REFER TO 'ROOF PENETRATION DETAIL' DRAWING E-601.
2 PROVIDE LIGHTNING PROTECTION BONDING TO ROOF DRAIN.
3 ROUTE CIRCUIT VIA MOTOR STARTER LOCATED IN THE MAIN ELECTRICAL ROOM.
4 MAINTENANCE RECEPTACLE FURNISHED, INSTALLED, AND FACTORY WIRED IN UNIT BY
MECHANICAL CONTRACTOR.
SYMBOL
GENERAL NOTES E-501
1 COMPLETED INSTALLATION FOR LIGHTNING PROTECTION SHALL MEET UL96A
INSTALLATION REQUIREMENTS FOR LIGHTING PROTECTION SYSTEMS, NFPA 780, AND
PROJECT SPECIFICATIONS. A CERTIFICATE OF COMPLETION FROM AN AUTHORITY HAVING
JURISDICTION SHALL BE FURNISHED TO THE CONTRACTING OFFICER UPON COMPLETION.
2 ALUMINUM LIGHTNING PROTECTION SYSTEM COMPONENTS SHALL NOT BE MOUNTED TO
COPPER SURFACES.
3 ADHESIVE USED WITH ADHESIVE AIR TERMINAL BASES AND CONDUCTOR FASTENERS
SHALL BE COMPATIBLE WITH ROOFING MEMBRANE. VERIFY WITH ROOFING CONTRACTOR.
4 AIR TERMINALS SHALL PROJECT A MINIMUM 10" ABOVE THE PROJECTED EDGE. SPACING
BETWEEN AIR TERMINALS IS NOT TO EXCEED 20 FEET.
5 ALL LIGHTNING CONDUCTORS ARE TO MAINTAIN A HORIZONTAL OR DOWNWARD PATH.
ALL CONDUCTOR BENDS SHALL HAVE A RADIUS BEND OF 8" OR GREATER AND SHALL
HAVE AN ANGLE BEND OF 90 DEGREES OR GREATER.
6 NOT ALL INDIVIDUAL COMPONENTS OF THE LIGHTNING PROTECTION SYSTEM ARE
LABELED FOR SAKE OF CLARITY PURPOSES. A COMPLETE SYSTEM SHALL BE PROVIDED
TO MEET MASTER LABEL REQUIRMENTS.
7 FOR LIGHTNING CONDUCTORS ROUTED ON HORIZONTAL ROOF SURFACE, PROVIDE
ADHESIVE CABLE HOLDERS EVERY 3'-0" MAXIMUM.
8 FOR LIGHTING CONDUCTORS ROUTED ALONG PARAPET, PROVIDE CABLE CLIPS WITH
STAINLESS STEEL SCREWS EVERY 3'-0" MAXIMUM.
8'4' 16'0
SCALE: 1/8"=1'-0"
AREA
A
KEY PLAN - AREA 'A'
GFCIGFCI
GFCI
DE C B
6.8
9.5
E.1 D.2 C.5 A
MDP- 5
MDP- 7
MDP- 6
WP
WP
WP
EF
CU
CU
DN
DN
DN
DOAS
M1A- 22
MDP- 3
M1A- 8,10
M1A- 31
M1A- 26
CU
CU
M1A- 15,17
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-502
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
R .H
A L T
E M
A N
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S A
IN
T
C H
A R
L E
S M
IS
S
O U
R I
E L E
C T
R
IC
A L R
O O
F P
L A
N A
R E
A B
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
SCALE: 1/8" = 1'-0"
ELECTRICAL ROOF PLAN AREA B
Plan
North TrueN orth
KEYED NOTES - E-502
1 REFER TO 'ROOF PENETRATION DETAIL DRAWING E-601.
2 PROVIDE LIGHTNING PROTECTION BONDING TO ROOF DRAIN.
3 ROUTE CIRCUIT VIA MOTOR STARTER LOCATED IN THE MAIN ELECTRICAL ROOM.
4 MAINTENANCE RECEPTACLE FURNISHED, INSTALLED, AND FACTORY WIRED IN UNIT BY
MECHANICAL CONTRACTOR.
SYMBOL
GENERAL NOTES E-502
1 COMPLETED INSTALLATION FOR LIGHTNING PROTECTION SHALL MEET UL96A
INSTALLATION REQUIREMENTS FOR LIGHTING PROTECTION SYSTEMS, NFPA 780, AND
PROJECT SPECIFICATIONS. A CERTIFICATE OF COMPLETION FROM AN AUTHORITY
HAVING JURISDICTION SHALL BE FURNISHED TO THE CONTRACTING OFFICER UPON
COMPLETION.
2 ALUMINUM LIGHTNING PROTECTION SYSTEM COMPONENTS SHALL NOT BE MOUNTED TO
COPPER SURFACES.
3 ADHESIVE USED WITH ADHESIVE AIR TERMINAL BASES AND CONDUCTOR FASTENERS
SHALL BE COMPATIBLE WITH ROOFING MEMBRANE. VERIFY WITH ROOFING
CONTRACTOR.
4 AIR TERMINALS SHALL PROJECT A MINIMUM 10" ABOVE THE PROJECTED EDGE. SPACING
BETWEEN AIR TERMINALS IS NOT TO EXCEED 20 FEET.
5 ALL LIGHTNING CONDUCTORS ARE TO MAINTAIN A HORIZONTAL OR DOWNWARD PATH.
ALL CONDUCTOR BENDS SHALL HAVE A RADIUS BEND OF 8" OR GREATER AND SHALL
HAVE AN ANGLE BEND OF 90 DEGREES OR GREATER.
6 NOT ALL INDIVIDUAL COMPONENTS OF THE LIGHTNING PROTECTION SYSTEM ARE
LABELED FOR SAKE OF CLARITY PURPOSES. A COMPLETE SYSTEM SHALL BE PROVIDED
TO MEET MASTER LABEL REQUIRMENTS.
7 FOR LIGHTNING CONDUCTORS ROUTED ON HORIZONTAL ROOF SURFACE, PROVIDE
ADHESIVE CABLE HOLDERS EVERY 3'-0" MAXIMUM.
8 FOR LIGHTING CONDUCTORS ROUTED ALONG PARAPET, PROVIDE CABLE CLIPS WITH
STAINLESS STEEL SCREWS EVERY 3'-0" MAXIMUM.
8'4' 16'0
SCALE: 1/8"=1'-0"
AREA
B
KEY PLAN - AREA 'B'
WEATHERPROOF GFCI DUPLEX
RECEPTACLE
WEATHERTIGHT FITTING
FLASHING
MEMBRANE
1/2" RGS CONDUIT
WATER
CUT-OFF
MASTIC
INSULATION
LABEL IDENTIFICATION FOR
TOP TWO PORTS
BOTTOM TWO PORTS
LABEL IDENTIFICATION FOR
B10/1A/B11
A10/1A/A11
CABLE FACEPLATE NUMBER
NOTES:
1.
SERVING ZONE
CABLE NUMBER
CABLE NUMBER
A10/1A/A11
2.
THE FACEPLATE SHALL BE LABELED WITH THE TERMINATION
LOCATION AND THE CABLE SERVING THE OUTLET.
THE CABLE NUMBER SHALL TERMINATE IN NUMBERICAL
ORDER IN THE PATCH PANEL OR ON THE 110 BLOCK.
PROVIDE BLANK INSERT IF PORT IS UNUSED.3.
6' - 0"
FRONT
(DRIVE
SIDE)
3' - 9" 3' - 9"
SIDE
CLEARANCE
SIDE
CLEARANCE
REAR (GRASS SIDE)
CLEARANCE
FRONT
CLEARANCE
2' - 8"
TIME SWITCH OPERATING SCHEDULE
PANEL TIME
SWITCH
LOAD #
OPERATES
TIME
ON
TIME
OFF
MULTIPLESPANEL
NUMBER
CKT.
DUSK DAWN
DUSK DAWN
DUSK 12:00 PM
DUSK 12:00 PM
DUSK 12:00 PM
DUSK 12:00 PM
DUSK 12:00 PM
DUSK 12:00 PM
DUSK 12:00 PM
DUSK 12:00 PM
DUSK 12:00 PM
DUSK DAWN
DUSK 12:00 PM
(USED FOR
OVERRIDE)
MULTIPLE
OUTGOING
LIGHTING
CIRCUITS
MULTIPLE
INCOMING
LIGHTING
CIRCUITS
LCP
ELECTRONIC
TIME SWITCH
120VAC
INPUT
L1A
16 EXTERIOR LTG - WEST
18 TRELLIS LTG - NORTH
PARKING/DRIVE LIGHTING
20 UPLIGHTS - EAST
SIDEWALK LIGHTING - SOUTH
22 ENTRANCE LIGHTS
24 PATH LIGHTS
SPARE
SPARE
SPARE
SPARE
SPARE
ELEC
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-601
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
R .H
A L T
E M
A N
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S
A
IN
T C
H A
R L
E S
M
IS
S
O U
R I
E L E
C T
R
IC
A L D
E T
A
IL
S
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
ROOF PENETRATION DETAIL
DATA FACEPLATE
TRANSFORMER CLEARANCES
SITE LIGHTING CONTROL
KEYED NOTES - E-601
1 "TIME ON" AND "TIME OFF" SETTINGS SHOWN ARE INITIAL SUGGESTED
TIMES. FINAL SETTINGS SHALL BE DETERMINED BY THE CONTRACTING
OFFICER AT TIME OF INSTALLATION. E.C. SHALL BE INITIALLY RESPONSIBLE
FOR SETTING "ON/OFF" TIMES.
2 THESE LOAD CONTROL CONTACTS SHALL BE SWITCHED SIMULTANEOUSLY
TO PROVIDE EFFECTIVELY A TWO POLE LOAD CAPABILITY.
50H2
U L
AIR TERMINAL
AIR TERMINAL BASE
MOUNTED VERTICALLY,
CONCEALED BEHIND
PARAPET.
CABLE FASTENER
CONDUCTOR
GROUNDING DOWN
CONDUCTOR.
GROUND ROD
CLAMP.
COPPER, COPPER CLAD,
STAINLESS STEEL GROUND
ROD
LIGHTNING GROUNDING
CONDUCTOR.
GROUND ROD CLAMP
COPPER, COPPER CLAD,
STAINLESS STEEL GROUND
ROD
SECONDARY BOND TO FLASHING.
THROUGH ROOF CABLE CONNECTOR.
SEAL ROOF PENETRATION AS REQUIRED (FURNISHED AND
INSTALLED BY THE ROOFING CONTRACTOR).
1" SCH 40 PVC CONDUIT. CONDUIT SHALL BE
FURNISHED AND INSTALLED BY THE ELECTRICAL
CONTRACTOR WITH PULL TAPE AND CAPS AT EACH
END. CONDUIT SHALL ROUTE CONDUCTORS IN A MANNER
CONSISTENT WITH THEIR BEND REQUIREMENTS
COPPER DOWN CONDUCTOR. CONDUCTOR
BENDS SHALL BE A MINIMUM 8 INCHES IN RADIUS AND NOT LESS
THAN 90 DEGREES IN ANGLE
SLEEVE AND SEAL AS REQUIRED (FURNISHED AND
INSTALLED BY GENERAL CONTRACTOR)
24"
DOWN CONDUCTOR TO CONNECTION WITH GROUND
SYSTEM.
CONDUCTOR TO ROOF LIGHTNING PROTECTION
SYSTEM
EXTERIOR WALL
PARAPET
SECONDARY BOND TO FLASHING.
THROUGH ROOF CABLE CONNECTOR.
SEAL ROOF PENETRATION AS REQUIRED
(FURNISHED AND INSTALLED BY THE ROOFING
CONTRACTOR).
THROUGH ROOF SLEEVE.
8 SQUARE INCH BONDING PLATE
CONNECTED TO CLEANED BARE METAL SURFACE
OF STEEL.
1" SCH 40 PVC CONDUIT. CONDUIT SHALL BE
FURNISHED AND INSTALLED BY THE ELECTRICAL
CONTRACTOR WITH PULL TAPE AND CAPS AT EACH
END. CONDUIT SHALL RUN CONTINUOUS BETWEEN
BONDS
COPPER DOWN CONDUCTOR
STEEL COLUMN BONDED TO LIGHTNING PROTECTION
SYSTEM AT TOP AND BOTTOM OF DOWN CONDUCTOR.
8 SQUARE INCH BONDING PLATE CONNECTED TO
CLEANED BARE METAL SURFACE OF STEEL.
SLEEVE AND SEAL AS REQUIRED (FURNISHED
AND INSTALLED BY GENERAL CONTRACTOR)
COPPER DOWN CONDUCTOR TO CONNECTION
WITH GROUND SYSTEM.
CONDUCTOR TO ROOF LIGHTNING PROTECTION SYSTEM
COPPER DOWN CONDUCTOR
LIGHTNING PROTECTION CONDUCTORS
AIR TERMINAL
LIGHTNING PROTECTION CONDUCTOR
FASTEN CONDUCTORS WITH ALUMINUM CABLE
LOOPS. LIGHTNING PROTECTION
CONDUCTORS SHALL BE FASTENED AT
INTERVALS NOT MORE THAN 36" ON CENTER.
CAST ALUMINUM EQUIPMENT AIR
TERMINAL BASE. FASTEN BASE WITH (2)
STAINLESS STEEL SELF TAPPING
SCREWS. SEAL PENETRATIONS WITH
TRANSLUCENT SILICONE.
EXTRUDED PARALLEL CABLE SPLICER:
MAKE COPPER TO ALUMINUM CONDUCTOR
CONNECTIONS WITH A BIMETALLIC CONNECTOR (WHERE
REQUIRED)
CROSS RUN PARALLEL
PARALLEL PARALLEL
BI-METAL
BONDING HEAVY DUTY
BONDING BONDING LUG
FLANGE BONDING PLATE
AIR TERMINAL
SURFACE AIR
TERMINAL BASE
MOUNTED
HORIZONTALLY
CONDUCTOR
ADHESIVE
CABLE
FASTENER
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
E-602
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T S
.S L O
T T
E N
S .S
L O
T T
E N
R .H
A L T
E M
A N
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S
A
IN
T C
H A
R L
E S
M
IS
S
O U
R I
E L E
C T
R
IC
A L D
E T
A
IL
S
L
IG
H T
N
IN
G P
R O
T E
C T
IO
N
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
AIR TERMINAL - PARAPET
LIGHTNING - GROUND ROD
LIGHTNING - DELTA GROUND
CONCEALED DOWN CONDUCTOR
CONCEALED DOWN CONDUCTOR BONDED TO STEEL
AIR TERMINAL EXHAUST FAN CONNECTION
TYPICAL CONNECTOR TYPES
TYPICAL BONDING PLATE TYPES
AIR TERMINAL - HORIZONTAL BASE
DOAS
M
'MDP'
600 AMP, 480V, 3P, 3W, 35KAIC
45A 3P
600A / 3P
MAIN
300A 3P
50A 3P
4 5 6
T1
4 6
L1A P1A
P1B
M
35A 3P
126 126 128
G N
3 4
#8 CU
200A 3P
600A / 3P
MAIN
100A 3P
200A 3P
4 5 6
'DPA'
600 AMP, 208Y/120V, 3P, 4W, 25KAIC
M1A
DOAS
60A 3P
CU
CU
7 8
SPACE
20A 3P
50A 3P
CU
CU
MODULE 1 MODULE 2
SPACE
62-1/2" C
SPD
100A 3P
SPACE SPACE
SPACE
DETAIL NOTES:
PANEL - MDP
1#4 AWG CU
CONDUCTOR
CONCRETE ENCASED ELECTRODE
UFER GROUND NOT LESS THAN 1/2"
DIAMETER AT LEAST 20FT LONG
(MINIMUM 2" CONCRETE)
BONDING PLATE-
CADWELD PER
SPECIFICATIONS
STEEL COLUMN
UNDERGROUND WATER PIPE
PIPE BONDING CLAMP
CONNECTIONS MADE
WITHIN 5 FEET OF
ENTRANCE OF PIPE
CONNECTION TO REBAR-
CADWELD PER
SPECIFICATIONS
"SERVICE
ENTRANCE
RATED"
1#3/0 AWG CU
CONDUCTOR
1#6 AWG CU
CONDUCTOR
GROUNDING
TERMINATION BAR
(NEC 250.94)
1#3/0 AWG
CU
CONDUCTOR
1/4"
12"
4"
CADWELD LUG (TYP.)
GROUND BAR
1#3/0 AWG CU
ELECTRODE
CONDUCTOR
600A 3P
SUPPORT
BRACKET
PLATE
HORIZONTAL SPLICE-
CADWELD PER
SPECIFICATIONS
GROUND ROD,
MINIMUM
3/4"x10' LENGTH
1#6 AWG CU
CONDUCTOR
BONDING CONDUCTOR FOR TELECOMMUNICATION. CONNECT MINIMUM #6 AWG COPPER CONDUCTOR TO INTERSYSTEM
BONDING TERMINATION BAR.
NEAREST POINT OF BUILDING STEEL.
E.C. SHALL PROVIDE A 4"x1/4"x12" COPPER GROUND BUS BAR.
LOCATE GROUND ROD AT BUILDING EXTERIOR, ADJACENT TO COLD WATER PIPE ENTRY POINT.
TRANSFORMER SCHEDULE
(DRY TYPE UNLESS OTHERWISE NOTED) * F = FLOOR W = WALL C = SUSPENDED FROM STRUCTURAL CEILING
NO. KVA
PRIMARY SECONDARY MOUNTING*
REMARKS
VOLTS PHASE-WIRES VOLTS PHASE-WIRE F W C
T1 225 480 3-3 120/208 3-4 x
FEEDER SCHEDULE
FEEDER
NUMBER
RATED
AMPS
C O
N D
U C
T O
R T
Y P
E C
O P
P E
R
* CONTRACTOR TO VERIFY ACTUAL ROUTING AND APPLICATION OF FEEDER
INSTALLATION AND RESIZE CONDUCTORS AND / OR CONDUIT FOR VOLTAGE DROP
(IF APPLICABLE), MEETING MINIMUM GUIDELINES OF THE NEC. REFER TO SPECIFICATIONS FOR PROPER CONDUIT TYPE SELECTION FOR DIFFERENT INSTALLATION APPLICATION / LOCATIONS.
* GROUNDS SIZED PER NEC TABLE 250.122
CONDUIT & WIRE SIZE
60 D
100 Y
200 Y
3/4"C - 3#6 + 1#10 EG
BASED ON THHN / THWN IN
EMT
1-1/4"C - 4#3 + 1#8 EG
2"C - 4#3/0 + 1#6 EG
125 Y 1-1/2"C - 4#1 + 1#6 EG
250 Y 2-1/2"C - 4#250 KCMIL + 1#4 EG
300 D 3"C - 3#350KCMIL + 1#4 EG
600 D 2 SETS - 3"C - 3#350KCMIL + 1#1 EG
20 D 3/4"C - 3#12 + 1#12 EG
50 D 3/4"C - 3#8 + 1#10 EG
600 Y 2 SETS - 3"C - 4#350KCMIL + 1#1 EG
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIM…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.