A02WISSCPlans_Part3.pdf
PDF 9 MB Posted
- Attached to
- WELDON SPRING Federal contract opportunity
- Solicitation number
- W912P9-19-R-0022_
About this file
WELDON SPRINGS PLANS 3 OF 8
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A02WISSCPlans_Part1.pdf | ||
| A02WISSCPlans_Part6.pdf | ||
| A02WISSCPlans_Part8.pdf | ||
| A02WISSCPlans_Part2.pdf | ||
| A02WISSCPlans_Part7.pdf | ||
| A02DOEInterpretiveCenterAdvSpecs.pdf | ||
| A02WISSCPlans_Part4.pdf | ||
| A02WISSCPlans_Part5.pdf | ||
| A22W912P919R0022.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pr eli m inar y
Not F or C onstr ucti on
US Army Corps of Engineers ®
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R I P
T I O
N
U S
A
R M
Y
C
O R
P
O
F
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
C T
N
S O
L I C
I T
A T
I O
N
N
O
DISCLAIMER OF RESPONSIBILITY
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING
CORPORATION CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY
CORPORATION CERTIFICATE LIC. NO.: 000078
Copyright © 2017 Kuhlmann design Group, Inc. All rights reserved.
C:\My Revit Local\722_DOE Interpretive Center_paul.brickler@kdginc.com.rvt
10/5/2017 4:44:25 PM
FINAL SUBMITTAL
S T
L O
U I
D
S
T R
I C
T
R T
S
J M
U
R T
S
M
I S
S O
U R
I
H
I G
H W
Y
S A
I N
T
C
H A
R L E
S
M
I S
S O
U
D E
P A
R T
M E
E
N E
R G
Y
L E
G A
M
N
A G
E M
E N
T
W E
L D
R
I N
G
S
I T
E
I N
T E
R P
R E
T I V
E
C
E N
T E
R
C-303
E R
O S
I O
N
C
O N
T R
O L
S W
P P
P
D
E T
A I L
T
E S
ANY DEBRIS CONTAINING RESIDUAL SOIL MUST BE PROPERLY MANAGED OF ON-SITE
IN THE OWNER'S DESIGNATED AREA. SEE SITE MAP, C4/C-001.
S
S
D
D
S
S
S
D
D
G
DD D
D
D
D
WW
D
D
BM#1
20"
2"
22"
22"
6"
10"
4"
3"
6"
2"
2"
5"
3"
CB
CB
W
W
MW
MW
T
T
F
O
I
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
F
O
S A
N
CB
F
O
F
O
F
O
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CO
CO
CO
CO
CO
CO
CO
W
EXISTING
INTERPRETIVE
CENTER
EX
OFFICES
EX
LAB
BLDG
HWY 94
S
O
L
D
I
E
I
V
E
H
W
NEW
INTERPRETIVE
CENTER
PARKING LOT TO
REMAIN OPEN DURING
CONSTRUCTION
THIS AREA MAY BE USED BY
THE CONTRACTOR FOR
STAGING, EQUIPMENT AND
MATERIAL STORAGE, SITE
OFFICE / TRAILER, PORTABLE
SANITARY FACILITIES AND
EMPLOYEE PARKING
CONSTRUCTION
EQUIPMENT
SITE ACCESS
AREA TO BE PROTECTED
DURING CONSTRUCTION
INTERPRETIVE CENTER
ACCESS TO REMAIN OPEN
DURING CONSTRUCTION
VISITOR SITE ACCESS TO REMAIN
OPEN DURING CONSTRUCTION
EX STORM
ACCESS TO AND PARKING
FOR EXISTING BUILDINGS
TO REMAIN OPEN DURING
CONSTRUCTION
SHELTERS
Pr eli m inar y
Not F or C onstr ucti on
US Army Corps of Engineers ®
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R I P
T I O
N
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
DISCLAIMER OF RESPONSIBILITY
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING
CORPORATION CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY
CORPORATION CERTIFICATE LIC. NO.: 000078
Copyright © 2017 Kuhlmann design Group, Inc. All rights reserved.
C:\My Revit Local\722_DOE Interpretive Center_paul.brickler@kdginc.com.rvt
10/5/2017 4:44:25 PM
FINAL SUBMITTAL
S T
L O
U
S
T R
I C
T
R T
S
J M
U
R T
S
M
I S
S O
U R
I
H
I G
H W
S A
I N
T
C
H A
R L E
S
M
I S
S O
U
D E
P A
R T
M E
E
N E
R G
Y
L E
G A
N
A G
E M
E N
T
W E
L D
R
I N
G
S
I T
E
I N
T E
R P
R E
T I V
E
C
E N
T E
R
C-400
C O
N S
T R
U C
T I O
N
S T
A G
I N
G
P
L A
N
STAGING AREA REQUIREMENTS
1. CONTRACTOR SHALL USE SITE AREA DESIGNATED SPECIFICALLY BY
OWNER AS CONTRACTOR STAGING AREA FOR THE PROJECT.
2. CONTRACTOR STAGING AREA SHALL BE CLEARLY INDICATED ON SITE
3. CONTRACTOR SHALL PROVIDE A CLEAR ACCESS ROUTE TO EXISTING
BUILDINGS, STORM SHELTERS AND TRAILS AT ALL TIMES.
4. CONTRACTOR SHALL KEEP CONSTRUCTION STAGING AREA CLEAR OF
TRASH AND DEBRIS AND IN NEAT ORDER.
5. CONTRACTOR SHALL CLEAN AND REPAIR DAMAGE CAUSED BY
INSTALLATION OR USE OF TEMPORARY FACILITIES AND STORAGE OF
EQUIPMENT AND MATERIALS.
6. CONTRACTOR SHALL BE CAUTIOUS TO NOT INTERFERE WITH BUS
TRAFFIC AND OTHER SITE TRAFFIC ASSOCIATED WITH INTERPRETIVE
CENTER PROGRAMS.
7. PROTECTION: PROVIDE TEMPORARY BARRICADES AND OTHER FORMS OF
PROTECTION AS REQUIRED TO PROTECT GENERAL PUBLIC FROM INJURY
DUE TO DEMOLITION WORK, CONSTRUCTION ACTIVITIES, OR VANDALISM.
ANY SAFETY FENCING, TRAFFIC CONTROL DEVICES, ETC. WHICH AFFECT
TRAFFIC AND/OR ANY STREET RIGHTS-OF-WAY, MUST BE PRE-APPROVED
BY THE OWNER AND/OR COUNTY IN ADVANCE.
00 50' 100'
CONSTRUCTION STAGING PLAN
A1
SCALE: 1" = 50'
CB-10D
15" W/DOME LID
STA: 6+69.62
RIM: 657.88
INV. OUT: 653.11
SUMP: 652.61
CB-9D
12" W/DOME LID
STA: 6+28.12
RIM: 658.41
INV IN: 653.20 (W)
INV OUT: 652.70
SUMP: 652.20
CB-8D
12" W/DOME LID
STA: 5+94.25
RIM: 658.32
INV. IN:652.53 (W)
INV. OUT:652.53
SUMP: 652.03
CO-7D
90° BEND
24" W/SOLID LID
STA: 5+69.35
RIM: 660.25
INV. IN:652.40 (W)
INV. OUT:652.40
SUMP: 651.90
CO-6D
30" W/SOLID LID
STA: 5+07.43
RIM: 659.04
INV. IN: 654.77 (W)
INV. IN: 652.09 (S)
INV. OUT: 652.09
SUMP: 651.59
CO-5D
15" W/SOLID LID
STA: 4+22.18
RIM: 657.73
INV. IN: 651.67 (S)
INV. OUT: 651.67
SUMP: 651.17
CO-4D
90° BEND
24" W/SOLID LID
STA: 2+98.97
RIM: 653.87
INV. IN: 649.90 (S)
INV. OUT: 649.90
SUMP: 649.40
CO-3D
24" W/SOLID LID
STA: 2+08.51
RIM: 657.42
INV. IN: 649.00 (S)
INV. OUT: 649.00
SUMP: 648.50
12" PIPE
GRADE = 1.0%
41'34'25'62'85'123'90'50'
12" PIPE
GRADE = 0.5%
12" PIPE
GRADE = 0.5%
12" PIPE
GRADE = 0.5%
12" PIPE
GRADE = 0.5%
12" PIPE
GRADE = 1.4%
12" PIPE
GRADE = 1.0%
12" PIPE
GRADE = 1.0%
PR SAN
PR CONC
WALK
PR CONC
WALK
PR CONC
WALK
PR CONC
WALK
PR CONC
WALK
PR CONC
WALK
PR ASPH
DRIVE
PR GRADE
PR GRADE
EX GRADE
PR GRADE
EX GRADE
PR GRADE
EX GRADE
PR GRADE
EX GRADE
PR GRADE
ROOF DRAIN,
SEE PLUMBING
PLANS
ROOF DRAIN,
SEE PLUMBING
PLANS
ROOF DRAIN,
SEE PLUMBING
PLANS
ROOF DRAIN,
SEE PLUMBING
PLANS
GRANULAR
BACKFILL
GRANULAR
BACKFILL
GRANULAR
BACKFILL
GRANULAR
BACKFILL
GRANULAR
BACKFILL
209'
PR FIRE WATER
AND DOMESTIC
WATER
M
I N
CO-2D
24" W/SOLID LID
STA: 0+00.00
RIM: 657.65
INV. IN: 651.53 (S)
INV. IN: 648.50 (E)
INV. OUT: 648.50
SUMP: 648.00
6" PIPE,
SEE DETAIL
F5/C502
6" PIPE, SEE
DETAIL D9
AI-1D
60" DIA. AREA INLET
STA: 0+00.00
SILL: 651.01
INV. IN: 646.91 (E)
INV. IN: 645.55 (S)
INV. OUT: 645.55
EX GRADE
12" PIPE
GRADE = 1.0%
158'
EX 30" PIPE
17'
6" PIPE
GRADE = 2.0%
CB-11D
12" W/DOME LID
STA: 0+17.49
RIM: 658.63
INV. OUT: 655.12
SUMP: 654.62
NEW INTERPRETIVE
CENTER WALL
PR CONC
WALK
EX ASPH
PVMT
12"
PIPE, SEE
DETAIL A1
CO-6D
30" W/SOLID LID
STA: 5+07.43
RIM: 659.04
INV. IN: 654.77 (W)
INV. IN: 651.99 (S)
INV. OUT: 651.99
SUMP: 651.49
ROOF DRAIN,
SEE PLUMBING
PLANS
Pr eli m inar y
Not F or C onstr ucti on
US Army Corps of Engineers ®
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R I P
T I O
N
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
DISCLAIMER OF RESPONSIBILITY
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING
CORPORATION CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY
CORPORATION CERTIFICATE LIC. NO.: 000078
Copyright © 2017 Kuhlmann design Group, Inc. All rights reserved.
C:\My Revit Local\722_DOE Interpretive Center_paul.brickler@kdginc.com.rvt
10/5/2017 4:44:25 PM
FINAL SUBMITTAL
S T
L O
U
S
T R
I C
T
R T
S
J M
U
R T
S
M
I S
S O
U R
I
H
I G
H W
S A
I N
T
C
H A
R L E
S
M
I S
S O
U
D E
P A
R T
M E
E
N E
R G
Y
L E
G A
N
A G
E M
E N
T
W E
L D
R
I N
G
S
I T
E
I N
T E
R P
R E
T I V
E
C
E N
T E
R
CATCH BASIN/JUNCTION
F6
M
I N
6"
(MIN.)
6"
(MIN.)
M
I N
REINFORCE CONCRETE PIPE
F9
SCALE: N.T.S.
OUTSIDE OF
PIPE BELL
OUTSIDE OF
PIPE BARREL
F
L
PLANE OF
SPRING LINE
COMPACTED CRUSHED
LIMESTONE AND
SCREENINGS
6" TO 18"PIPE) EXCEPT
C-501
S I T
E
D
E T
A I L
S
S T
O R
N
I T
A R
Y
S E
W E
R
M A
T C
H
L I N
E
S
E
T
A I L
D
STORM SEWER PROFILE
A1
SCALE: N.T.S.
STORM SEWER PROFILE
D6
SCALE: N.T.S.
M A
T C
H
L I N
E
S
T
A I L
A
STORM SEWER PROFILE
D9
SCALE: N.T.S.
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING
THE REQUIREMENTS OF CLASS I, CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.
BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED
UNIFORMLY IN ACCORDANCE WITH ASTM D2321.
TOP SOIL
FRAME & GRATE/COVER
WITH LOCKING LID 8" MIN THICKNESS GUIDELINE
NOTES:
1. SOLID COVERS SHALL MEET H-20 LOAD RATING.
2. DOME COVERS SHALL MEET H-10 LOAD RATING.
3. ALL COVERS SHALL BE SAME MANUFACTURER AS
CATCH BASIN.4" MIN ON 12" - 24"
6" MIN ON 30"
MINIMUM PIPE BURIAL DEPTH
PER PIPE MANUFACTURER
RECOMMENDATION
18" MIN
THICKNESS
BOTTOM FLANGE OF FRAME MUST BE
SUPPORTED BY CONCRETE COLLAR
ADAPTER RING
V A
R I E
S
INLET BASE AND INLET MANHOLE BASE
SEE DETAIL D1/C5-02
PRECAST CONCRETE AREA INLET
D1
SCALE: N.T.S.
I
N
CAST IRON COVER
WITH LOCKING LID
SHIPPED AS
ONE UNIT
3/4" MORTAR BED JOINT
(2) 5/8" DIA. - 1'-0" PINS
ADJUST TO FINAL
GRADE WITH GRADE
RINGS
3/4" MORTAR
BED JOINT
APPROVED PATENTED
COMPRESSION TYPE
JOINT
APPROVED
JOINT
4 WAY CONCRETE UNIT
INLET STONE
8" 8"
58"
48"
8" 8"
"Ø HOLE
"Ø HOLE
4-#3 REBAR
4-#3 REBAR
PLAN
SECTION A-A
NOTES
1. SET STANDARD INLET STONE IN
" MORTAR BED AND DOWEL WITH
"Ø
1'-0" LONG PINS AND GROUT
2. RAISE TO FINAL GRADE WITH COURSES OF BRICK AND SET THE UNIT TO
BASE WITH
" MORTAR BED
3. 5,000 P.S.I. CONCRETE IS REQUIRED
AA
4 WAY CONCRETE UNIT
4-#3
REBAR
PIPE BEDDING (FOR ALL
ADS NYLOPLAST
DRAINAGE STRUCTURES
OR APPROVED EQUAL
NOTE:
UTILITY BEDDING SHOULD NOT INCLUDE GRAVEL WITHIN 4 FEET
OF THE PERIMETER OF THE FOUNDATION. COMPACTED CLAY OR
FLOWABLE FILL TRENCH BACKFILL SHOULD BE USED IN LIEU OF
PERMEABLE BEDDING MATERIALS BETWEEN 2 FEET INSIDE THE
BUILDING TO A DISTANCE OF 4 FEET BEYOND THE EXTERIOR OF
THE BUILDING EDGE TO REDUCE THE POTENTIAL FOR WATER TO
INFILTRATE WITHIN UTILITY BEDDING AND BACKFILL MATERIAL.
M
I N
319'
305'
EXISTING UTILITIES IN THIS AREA
COMMUNICATIONS, WATER,
SANITARY FORCE MAIN AND STORM SEWER
MH-4S
MANHOLE
STA: 6+47.31
RIM: 659.39
INV. IN: 654.55
INV. OUT: 654.45
MH-3S
MANHOLE
STA: 3+36.60
RIM: 658.79
INV. IN: 652.60
INV. OUT: 652.50
8" PVC
GRADE = 0.65%
8" PVC
GRADE = 0.65%
PR STM
4" PVC, SEE
PLUMBING PLANS
PR CONC
WALK
NEW INTERPRETIVE
CENTER WALL
GRANULAR
BACKFILL
GRANULAR
BACKFILL
GRANULAR
BACKFILL
EX ASPH
PVMT
EX ASPH
PVMT
EX ASPH
PVMT
EX GRADE
18'
X
EXISTING FENCE
MH-2S
MANHOLE
STA: 0+18.06
RIM: 656.74
INV. IN: 650.56
INV. OUT: 650.46
MH-1S
EX MANHOLE
STA: 0+00.00
RIM: 656.65
INV. IN: 650.35 (N)
INV. IN: 649.99 (E)
INV. OUT: 649.99
8" PVC
GRADE = 0.65%
8" PVC
GRADE = 0.65%
319'
CO-12D
12" W/SOLID LID
STA: 0+67.95
RIM: 657.61
INV. OUT: 653.39
SUMP: 652.89
CO-2D
24" W/SOLID LID
STA: 0+00.00
RIM: 657.65
INV. IN: 651.53 (S)
INV. IN: 648.50 (E)
INV. OUT: 648.50
SUMP: 648.00
GRANULAR
BACKFILL
6" PIPE
GRADE
= 2.0%
68'
PR CONC
WALK
PR GRADE
EX GRADE
ROOF DRAIN,
SEE PLUMBING
PLANS
12" PIPE,
SEE DETAIL A1/C-501
Pr eli m inar y
Not F or C onstr ucti on
US Army Corps of Engineers ®
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R I P
T I O
N
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
DISCLAIMER OF RESPONSIBILITY
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING
CORPORATION CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY
CORPORATION CERTIFICATE LIC. NO.: 000078
Copyright © 2017 Kuhlmann design Group, Inc. All rights reserved.
C:\My Revit Local\722_DOE Interpretive Center_paul.brickler@kdginc.com.rvt
10/5/2017 4:44:25 PM
FINAL SUBMITTAL
S T
L O
U
S
T R
I C
T
R T
S
J M
U
R T
S
M
I S
S O
U R
I
H
I G
H W
S A
I N
T
C
H A
R L E
S
M
I S
S O
U
D E
P A
R T
M E
E
N E
R G
Y
L E
G A
N
A G
E M
E N
T
W E
L D
R
I N
G
S
I T
E
I N
T E
R P
R E
T I V
E
C
E N
T E
R
C-502
S I T
E
D
E T
A I L
S
S T
O
N
I T
A R
Y
S E
W E
R
NOTES:
1. THE MINIMUM INSIDE DIAMETER FOR THE BASE AND RISER SECTIONS SHALL BE 48 INCHES FOR ALL SANITARY SEWERS AND ALL STORM SEWERS.
MANHOLE SHALL MEET ASTM C-478 REQUIREMENTS.
2. FLOWLINE ELEVATION OF INCOMING PIPES SHALL BE 1" HIGHER THAN THAT OF OUTGOING PIPE.
3. PRIOR TO FABRICATION, SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL OF ALL STRUCTURES.
8"
(TYP.)
M
A X
M
A X
42" I.D.
BASE SECTION
2 1/2"
M
I N
MANHOLE BASE PLAN
PRECAST CONCRETE MANHOLE
D1
SCALE: N.T.S.
ELEVATION
STANDARD MANHOLE
FRAME AND COVER
WITH LOCKING LID
ADJUST TO GRADE WITH
APPROVED GRADE RING
PROVIDE ADAPTOR RING WITH
42 INCH TOP OPENING DIAMETER
FOR INLET STRUCTURES
PROVIDE AND ADJUST RISER
SECTIONS SO THAT PIPE INLET
DOES NOT EXTEND THROUG
STRUCTURE JOINT.
RUBBER GASKET JOINT OR
APPROVED EQUAL
PRECAST RISER SECTION
SHAFT STEPS UNIFORMLY
SPACED AT 16" CTRS. NOT OVER
TOP OF PIPES, EXTEND 5
FROM WALL
PRECAST MANHOLE BASE
APPROVED PATENTED
COMPRESSION TYPE JOINT
FOR DROP PIPE, FACTORY CAST
OPENING AS REQUIRED.
APPROVED COMPRESSION TYPE
JOINT
ECCENTRIC PRECAST CONE
TOP SECTION, MANHOLES 42-48
INCHES
DEFLECTION ANGLE
AS REQUIRED
AREA OR REINFORCING
STEEL = .12 IN./ LIN. FT.
M A
T C
H
L I N
E
S
T
A I L
D
M A
T C
H
L I N
E
S
T
A I L
A
SANITARY SEWER PROFILE
A1
SCALE: N.T.S.
SANITARY SEWER PROFILE
D7
SCALE: N.T.S.
ASPHALT PAVEMENT TRENCH PATCH
F1
SCALE: N.T.S.
E X
I S
T
P V
M T
S E
C T
I O
N
GRANULAR
TRENCH BACKFILL
ASPHALT BASE TO MATCH
EXISTING PAVEMENT
SECTION THICKNESS
MODOT BP-1
3" ASPHALTIC CONCRETE
SURFACE COURSE
PRIME COAT
2' TYP TRENCH WIDTH 2' TYP
EXIST. PAVEMENT
SURFACE
SAW CUT LINE
SAW CUT LINE
STORM SEWER PROFILE
F5
SCALE: N.T.S.
NOTE:
UTILITY BEDDING SHOULD NOT INCLUDE GRAVEL WITHIN 4 FEET
OF THE PERIMETER OF THE FOUNDATION. COMPACTED CLAY OR
FLOWABLE FILL TRENCH BACKFILL SHOULD BE USED IN LIEU OF
PERMEABLE BEDDING MATERIALS BETWEEN 2 FEET INSIDE THE
BUILDING TO A DISTANCE OF 4 FEET BEYOND THE EXTERIOR OF
THE BUILDING EDGE TO REDUCE THE POTENTIAL FOR WATER TO
INFILTRATE WITHIN UTILITY BEDDING AND BACKFILL MATERIAL.
m inar y
Not F or C onstr ucti on
US Army Corps of Engineers ®
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R I P
T I O
N
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
DISCLAIMER OF RESPONSIBILITY
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING
CORPORATION CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY
CORPORATION CERTIFICATE LIC. NO.: 000078
Copyright © 2017 Kuhlmann design Group, Inc. All rights reserved.
C:\My Revit Local\722_DOE Interpretive Center_paul.brickler@kdginc.com.rvt
10/5/2017 4:44:25 PM
FINAL SUBMITTAL
S T
L O
U
S
T R
I C
T
R T
S
J M
U
R T
S
M
I S
S O
U R
I
H
I G
H W
S A
I N
T
C
H A
R L E
S
M
I S
S O
U
D E
P A
R T
M E
E
N E
R G
Y
L E
G A
N
A G
E M
E N
T
W E
L D
R
I N
G
S
I T
E
I N
T E
R P
R E
T I V
E
C
E N
T E
R
C-503
S I T
E
D
E T
A I L
S
W A
T E
R
S
E R
V I C
E
APPROX. MIN. "E"
M I N
C
M I N
M I N
A P
P R
O X
M
I N
D
"A"
RESTRAIN TO
VAULT
DOUBLE DETECTOR-CHECK DETECTOR CHECK ASSEMBLY VALVE
(ABLE TO BE TESTED BY CONSUMER)
INSULATED FLANGE
CONNECTION
BRASS
I.P. THREADS
I.P. THREADS
BRASS
FIRE
SERVICE
DRAIN TO
DAYLIGHT
DETECTOR
BY-PASS METER
BY WATER CO.
METER AND INSTALLATION
BY MO. AMERICAN WATER CO.
GENERAL
SERVICE
INSULATED FLANGE
CONNECTION
METER VAULT FOR SPLIT SERVICE - ELEVATION
METER VAULT FOR SPLIT SERVICE - PLAN
DOMESTIC SERVICE FIRE SERVICE
SIZE
BYPASS
MIN. SIZE A B
10" 8" 6" 4"
C D E C D E C D E C D E
IN. IN. IN. IN. IN. IN. IN. IN. IN. IN. IN. IN. IN. IN. IN. IN.
1 1/2 1 30 22
35 72 102 35 72 90 30 66 84 27 60 84
2 2 30 22
35 72 102 35 72 90 30 66 84 27 60 84
3 2 54 47
35 84 156 35 78 156 30 72 150 27 72 150
4 2 54 47
35 84 162 35 84 162 30 78 156 27 72 156
6 2 60 47
36 84 174 36 84 174 31 78 174
8 2 66 47
37 84 186 37 84 186
1. VAULTS WALLS TO BE OF CONCRETE OR PRECAST CONCRETE.
2. VAULT ROOF TO BE OF REINFORCED CONCRETE WITH OPENING CENTERED OVER GENERAL
SERVICE METER.
3. LIDS AND FRAMES OF OPENING TO BE SET IN PLACE NOT IN CONCRETE.
4. VALVES ON EACH SIDE OF GENERAL METER FOR 1 1/2" OR 2" SERVICE TO HAVE SCREW ENDS, I.P.
THREADS. FOR 3" AND ABOVE, VALVES MUST HAVE FLANGED ENDS AND BE IN ALIGNMENT. ALL
VALVES MUST BE ADEQUATELY SECURED TO WITHSTAND WATER THRUST WITH METER
REMOVED.
5. MINIMUM CLEARANCE OF 2' TO BE PROVIDED BETWEEN THE EDGES OF THE GENERAL METER
AND DETECTOR CHECK BYPASS METER.
6. DRAINAGE FACILITIES MUST BE PROVIDED, OR BOX OTHERWISE KEPT FREE OF WATER. NO
FRENCH DRAINS ALLOWED UNLESS APPROVED BY AUTHORIZED COMPANY REPRESENTATIVE.
7. DI PRESSURE CLASS 52 PIPE MINIMUM, EXTENDED MIN. 5' FROM OUTLET SIDE OF METER PIT.
8. TYPE "K" OR "L" COPPER ON DOMESTIC. EXTENDED MIN. 5' FROM OUTLET SIDE OF METER PIT.
9. ANY DEVIATION FROM PIPE DEPTH SHOWN MUST BE APPROVED BY AUTHORIZED COMPANY
REPRESENTATIVE PRIOR TO CONSTRUCTION.
10. METER BOX CONTROL VALVE TO BE LOCATED AS NEAR TO METER BOX AS PRACTICAL.
11. BOX TO BE SET WITH TOP OF BOX AT FINISHED GRADE WITH NO EXTENSION ALLOWED.
12. CONNECTIONS TO PUBLIC WATER MAIN WILL NOT BE MADE BEFORE METER PIT AND PIPING ARE
COMPLETE AND PROPERTY LINE VALVE INSTALLED UNLESS APPROVED BY AUTHORIZED
MISSOURI AMERICAN WATER COMPANY REPRESENTATIVE.
13. CUSTOMER SERVICE SUPERINTENDENT MUST APPROVE ALL MEGALUGS, UNIFLANGE TYPE
JOINTS IN METERBOX.
14. LIDS SHALL BE MADE OF ALUMINUM AND SPRING LOADED. OPENING SHALL BE 48"x48" TO ALLOW
UNRESTRICTED ACCESS. OPENING TO BE FLUSH WITH OUTLET SIDE OF DOMESTIC WATER
SERVICE VALVE FLANGE. LIDS SHALL BE LOCKABLE VIA A STANDARD TURNABLE BOLT.
METER BOX
CONTROL
VALVE WITH
STOP BOX
CORROSION
PROTECTION
APPROX. MIN. "B"
DRAIN TO
DAYLIGHT
TEST TEE STRAINER
WATER CO. OWNED
STRAINER
VALVE
OPENING IN ROOF
OPTIONAL
CONNECTION MADE BY CONTRACTOR
DUCTILE IRON
DUCTILE IRON
m inar y
Not F or C onstr ucti on
US Army Corps of Engineers ®
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R I P
T I O
N
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
DISCLAIMER OF RESPONSIBILITY
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING
CORPORATION CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY
CORPORATION CERTIFICATE LIC. NO.: 000078
Copyright © 2017 Kuhlmann design Group, Inc. All rights reserved.
C:\My Revit Local\722_DOE Interpretive Center_paul.brickler@kdginc.com.rvt
10/5/2017 4:44:25 PM
FINAL SUBMITTAL
S T
L O
U
S
T R
I C
T
R T
S
J M
U
R T
S
M
I S
S O
U R
I
H
I G
H W
S A
I N
T
C
H A
R L E
S
M
I S
S O
U
D E
P A
R T
M E
E
N E
R G
Y
L E
G A
N
A G
E M
E N
T
W E
L D
R
I N
G
S
I T
E
I N
T E
R P
R E
T I V
E
C
E N
T E
R
NOTE:
WHEN NEW CONCRETE CURB ABUTS EXISTING CURB OR NEW INTEGRAL CURB
& WALK, USE 1/2" THICK PREMOLDED EXPANSION JOINT FILLER.
G R
A D
E
6"
CONCRETE VERTICAL CURB
C5
SCALE: N.T.S.
1" R
1/4" R
P.C. CONCRETE CURB
PREPARED SUBGRADE
SAW CUT AND REMOVE
EXISTING PAVEMENT AS
REQUIRED TO CONSTRUCT
NEW CONCRETE CURB.
PATCH WITH NEW ASPHALT
PAVEMENT SECTION OR
MATCH EXISTING ADJACENT
PAVEMENT SECTION.
PRECAST CONCRETE
WHEEL STOP, LOCATE 2'-6"
FROM EDGE OF SIDEWALK
TO FRONT OF WHEEL STOP.
1/2"ØX12" LONG STEEL PIN
IN 3/4"Ø SLEEVE (TYP.)
FRONT ELEVATION
SIDE ELEVATION
X
N
U
M
B
E
P
S
TREAD
R I S
E
6"
#4 B-BARS AT
18"± CENTERS
#4 A-BARS AT
12"± CENTERS
4"
VARIABLE STEP WIDTH
SEE SITE PLAN
4"
V A
R I A
B L
E
H
E I G
H T
B B A R S
A T
C E N T E R S
2"
#4 A-BARS AT 12"± CENTERS
2"
TYPICAL CONCRETE STAIRWAY
E1
SCALE: N.T.S.
ASPHALTIC PAVEMENT SECTION
A5
SCALE: N.T.S.
C-504
S I T
E
D
E T
A I L
S
P A
V E
M E
N T
PREPARED SUBGRADE
MODOT TYPE 5 COMPACTED GRANULAR BASE
MODOT BP-1 ASPHALTIC CONCRETE SURFACE COURSE
PRIME COAT
MODOT PMBB ASPHALTIC CONCRETE BASE COURSE
NOTE: DETAIL INDICATES MINIMUM PAVEMENT
SECTION THICKNESS, MATCH ADJACENT EXISTING
PAVEMENT SECTION IF GREATER
M
I N
NOTE:
WHEN NEW CONCRETE CURB ABUTS EXISTING CURB OR NEW INTEGRAL
CURB & WALK, USE 1/2" THICK PREMOLDED EXPANSION JOINT FILLER.
A D
J A
C E
N T
S
ID
E W
A L K
6"
CURB FLUSH WITH PAVEMENT
C7
SCALE: N.T.S.
1/2" R
1/4" R
P.C. CONCRETE CURB
PREPARED SUBGRADE
M
I N
SIDEWALK WIDTH
VARIES
CURB FLUSH WITH
PAVEMENT
1'
TRANSITION
1'
TRANSITION
CONCRETE VERTICAL CURB
PAVEMENT GRADE
TO FLUSH WITH PAVEMENT
C9
SCALE: N.T.S.
M
I N
SAW CUT AND REMOVE
EXISTING PAVEMENT AS
REQUIRED TO CONSTRUCT
NEW CONCRETE CURB.
PATCH WITH NEW ASPHALT
PAVEMENT SECTION OR
MATCH EXISTING ADJACENT
PAVEMENT SECTION.
CONCRETE
CONCRETE WHEEL STOP
E9
SCALE: N.T.S.
"A" DIA.
18"
20"
16"
"B" DIA.
8"
6"
4"
HOLE FOR BOLLARD MAY BE
DRILLED AFTER PAVEMENT
INSTALLATION AT
CONTRACTORS OPTION.
SCHEDULE 40 STEEL PIPE
FILLED W/ CONCRETE AND
PAINTED YELLOW
PROPOSED PAVEMENT
CONCRETE
A
B
PIPE BOLLARD
A7
SCALE: N.T.S.
CURB TRANSITION
RAISED CONCRETE ISLAND
A9
SCALE: N.T.S.
1"
3/4"R
RAISED CONCRETE ISLAND
#5 TIE BAR (TYP.)
6" VARIES 6"
PAVEMENT
DRILLED HOLE SHALL
BE 3/4" DIA.
NOTE:
PLACE JOINTS MATCHING EXISTING JOINTS. WHEN THERE ARE NO VISIBLE
JOINTS IN THE ADJACENT PAVEMENT. THE JOINT SPACING WILL BE EQUAL TO
THE WIDTH OF THE RAISED ISLAND, WITH A MINIMUM SPACING OF 10 FEET.
SECTION
PLAN
#5 TIE BAR (TYP.)
5' (TYP.)
T
Y P
STEP DIMENSIONS
GRID
LOCATION
TREAD
(INCHES)
RISE
(INCHES)
NUMBERS
OF STEPS
C6/C-101 1'-0" 0'-6" 4
E1/C-102 1'-1 1/2" 0'-4 1/2" 13
C3/C-102 1'-0" 0'-6" 8
NOTE:
SEE ARCHITECTURAL
PLANS FOR RAILINGS AND
NOSINGS.
C O
A
I R
S
S I D
E W
A L
K
2.0% MAX. ANY DIRECTION
NON-REINFORCED CONCRETE PATIO
E5
SCALE: N.T.S.
EXPANSION JOINT
CONTROL JOINT
TYPICAL SECTION
PORTLAND CEMENT
CONCRETE
PREPARED SUBGRADE
1/2" CONTROL JOINT WITH
1/4" RD. OVER
1/2" EXPANSION JOINT WITH JOINT FILLER.
UNLESS OTHERWISE NOTED.
EXISTING
PATIO PROPOSED
PATIO
CONSTRUCTION
JOINT
EXPANSION
JOINT
EXPANSION
JOINT
EXPANSION
JOINT
BUILDING
PENETRATION
(i.e. COLUMN, DRAIN, OR SIGN)
EXPANSION JOINT
EXPANSION JOINT
EXPANSION JOINT
EXPANSION JOINT
X
R
B P
R
C
U R
B
DOOR STOOP
TYPICAL JOINT LOCATIONS
NOTES:
1. POSTS SHALL BE SET IN POST FOOTERS AS SHOWN OR
CORED
2. REFER TO SITE PLAN FOR RAMP DIMENSIONS AND
GRADING PLAN FOR SLOPES
3. UNLESS NOTED OTHERWISE, RAMP FINISH SHALL BE A
NON-SLIP HORIZONTAL BROOM FINISH
RETAINING WALL PROFILE W/ADA COMPLIANT RAMP AND HANDRAILS
A1
SCALE: N.T.S.
M
I
N
NOTES:
1. CONTRACTOR SHALL INSTALL JOINTS NOT TO EXCEED 7 FEET IN WIDTH.
PANELS SHALL BE KEPT AS SQUARE AS POSSIBLE, LENGTH TO WIDTH
SHALL NOT BE GREATER THAN 1.5:1. ACUTE ANGLES SHALL BE AVOIDED
2. CONTRACTOR SHALL INSTALL EXPANSION JOINTS WHEREVER
NECESSARY TO SEPARATE PATIO FROM OTHER BUILDING MEMBERS,
INCLUDING, BUT NOT LIMITED TO, COLUMNS, WALLS, EQUIPMENT
FOUNDATIONS, FOOTINGS, STAIRS, MANHOLES, SUMPS, AND DRAINS.
CONTROL JOINT
SLEEVE SET POST OPTION:
8" (MIN.) CONCRETE POST FOOTING.
SET IN 6" DEEP SLEEVES PACK WITH
NON-SHRINK GROUT
5'-0" (MIN.)
LANDING
2.0% (MAX.)
SLOPE
IN ANY
DIRECTION
30'-0" (MAX.) LENGTH SLOPE
SLOPE NOT TO EXCEED 8.33% (12:1)
2-6" (MAX.) RISE
5'-0" (MIN.)
LANDING
2.0% (MAX.)
SLOPE
IN ANY
DIRECTION
PROFILE
CONCRETE SIDEWALK,
SEE DETAIL F1/C-505
30'-0" (MAX.) LENGTH SLOPE
SLOPE NOT TO EXCEED 8.33% (12:1)
2-6" (MAX.) RISE
HANDRAIL POST EQUAL SPACING
5' (MAX.)
SEE ARCHITECTURAL
PLANS FOR HANDRAIL
5'-0" (MIN.)
LANDING
2.0% (MAX.)
SLOPE
IN ANY
DIRECTION
TOP OF RETAINING WALL
REFER TO PLAN FOR SIDEWALK WIDTH
1'
(MIN.)
36" (MIN.) CLEARANCE WIDTH
PIPE SLEEVE
CONCRETE SIDEWALK,
SEE DETAIL F1/C-505
COMPACTED
SUBGRADE
SLEEVE SET POST OPTION:
8" (MIN.) CONCRETE POST FOOTING. SET IN 6"
DEEP SLEEVES PACK WITH NON-SHRINK GROUT
TYPICAL SECTION
CONCRETE RETAINING
WALL, SEE STRUCTURAL
DETAIL 6/S-302
SEE ARCHITECTURAL PLANS
FOR HANDRAILS
EXPANSION
JOINT
EXPANSION
JOINT
V A
R I E
S
TOP OF
RETAINING WALL
ELEV.
662.55
ELEV.
662.55
ELEV.
658.00
T Y
P I C
A L
S E
C T
I
T
W
T
W
T
W
B
W
B
W
B
W
T
W
TOP OF WALL (TW)
BOTTOM OF
WALL (BW)
TOP OF LEVELING
PAD
EX GRADE
AT FACE OF WALL
APPROX. AREA
OF EXPOSED FACE
OF WALL = 78 S.F.
4'
20'
Pr eli m inar y
Not F or C onstr ucti on
US Army Corps of Engineers ®
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R I P
T I O
N
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
DISCLAIMER OF RESPONSIBILITY
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING
CORPORATION CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY
CORPORATION CERTIFICATE LIC. NO.: 000078
Copyright © 2017 Kuhlmann design Group, Inc. All rights reserved.
C:\My Revit Local\722_DOE Interpretive Center_paul.brickler@kdginc.com.rvt
10/5/2017 4:44:25 PM
FINAL SUBMITTAL
S T
L O
U
S
T R
I C
T
R T
S
J M
U
R T
S
M
I S
S O
U R
I
H
I G
H W
S A
I N
T
C
H A
R L E
S
M
I S
S O
U
D E
P A
R T
M E
E
N E
R G
Y
L E
G A
N
A G
E M
E N
T
W E
L D
R
I N
G
S
I T
E
I N
T E
R P
R E
T I V
E
C
E N
T E
R
ADA SIDEWALK CURB RAMP
A1
SCALE: N.T.S.
C-505
S I T
E
D
E T
A I L
S
P A
V E
M E
N T
SECTION A-A
PERPENDICULAR CONCRETE CURB RAMP
NOTES
ALL RAMPS SHALL NOT HAVE RUNNING SLOPES GREATER THAN 8.3% OR 1V:12H.
RAMP LENGTH NOT REQUIRED TO EXCEED 15 FEET.
NON-TRAVERERSABLE
FLARE OR VERTICAL
CURB
TRAVERSABLE FLARE
1V:10H (MAX.)
CURB HEIGHT
TRANSITION
SAME AS
APPROACH SIDEWALK
4'-0" (MIN.)
A
A
VARIABLE
RAMP SLOPE SHOULD BE AS FLAT
AS POSSIBLE, AND SHALL NOT
EXCEED 12V:1H (8.33%)
C
O N
C R
E T
E
C U
B
M
P
S
I D
E W
A L
K
T
Y P
ALGEBRAIC DIFFERENCE BETWEEN
PAVEMENT OR GUTTER SLOPE IN
DIRECTION OF PEDESTRIAN TRAVEL AND
CURB RAMP SLOPE SHALL NOT EXCEED
13.0%. PROVIDE 24" LEVEL LANDING IF
ALGEBRAIC DIFFERENCE EXCEEDS 13.0%.
DETAIL A
DETAIL A
NON-TRAVERERSABLE
FLARE
FULL CURB
HEIGHT
1'-0"
C U
R B
H E
I G
H
CONCRETE CURB
RAMP
TRANSISTION FROM
FULL CURB HEIGHT
TO 0"
T
O
FROM FRONT OF
CURB LINE
GENERAL NOTES:
ALL AREAS OF THE PEDESTRIAN ACCESS
ROUTE MUST BE COMPLIANT WITH THE
"AMERICANS WITH DISABLILITES ACT
ACCESSIBLILITY GUIDELINES (ADAAG)".
EXCEPTIONS MUST BE APPROVED BY THE
ENGINEER. ALL OTHER AREAS OF
NON-COMPLIANCE SHALL BE REMOVED AND
CORRECTED AT THE CONTRACTOR'S
EXPENSE.
FINISHED SIDEWALK SHALL BE STABLE, SLIP
RESISTANT AND SURFACE DOES NOT POND
WATER.
SIDEWALK AND RAMP CROSS SLOPES SHALL
BE A MINIMUM OF 1.0% TO FACILITATE
DRAINAGE AND A MAXIMUM OF 2.0% TO BE
USABLE FOR DISABLED INDIVIDUALS.
STORMWATER INLETS, SIGNS, POSTS,
MANHOLE COVERS, PULL BOXES AND OTHER
ACCESS LIDS SHOULD BE AVOIDED WITHIN
THE SIDEWALK. IF SUCH A LOCATION IS
NECESSARY, THE FEATURE MUST MEET ADA
STANDARDS.
THE RUNNING GRADE OF A SIDEWALK SHALL
NOT EXCEED 5.0% UNLESS IT IS MATCHING
THE GRADE OF THE ADJACENT ROADWAY.
1V:12H (MAX.)
PEDESTRIAN ACCESS ROUTE SHALL
CONTINUE ACROSS DRIVEWAYS AND
PARKING LOTS.
LANDINGS SHALL BE CONSTRUCTED AT THE
TOP AND/OR BOTTOM OF A CURB RAMP
WHEREVER A TURNING MOVEMENT IS
REQUIRED. LANDINGS LOCATED IN THE
ROADWAY MUST BE COMPLETELY
CONTAINED WITHIN THE CROSSWALK.
SIDE FLARES OF CURB RAMPS, IN THE PATH
OF PEDESTRIAN TRAVEL (TRAVERSABLE),
SHALL NOT EXCEED A SLOPE OF 1V:10H. SIDE
FLARES OUTSIDE THE PEDESTRIAN PATH
(NONTRAVERSABLE) MAY BE 1V:2H OR
VERTICAL.
TRANSITION FROM SIDEWALK TO GUTTER TO
ROADWAY MUST BE FLUSH.
WHEN IT IS TECHNICALLY NOT FEASIBLE TO
CONSTRUCT 1V:12H RAMP SLOPE, WHILE
ALTERING EXISTING PEDESTRIAN FACILITIES,
A SLOPE BETWEEN 1V:12H AND 1V:10H IS
PERMISSIBLE FOR A MAXIMUM RISE OF 6",
AND A SLOPE BETWEEN 1V:10H AND 1V:8H IS
PERMISSIBLE FOR A MAXIMUM RISE OF 3".
IF CONSTRUCTION OF 5' X 5' LANDING IS NOT
FEASIBLE, 4' X 4' LANDING MAY BE USED.
CONCRETE SIDEWALK SECTION
F1
SCALE: N.T.S.
PORTLAND CEMENT
CONCRETE
COMPACTED GRANULAR BASE
PREPARED SUBGRADE
EXPANSION JOINT
CONTROL JOINT
TYPICAL SECTION
EXIST.
WALK
EXISTING
WALK
C O
N C
R E
T E
S T
E P
S
SPACING EQUAL TO WIDTH OF WALK.
NOT TO EXCEED 50' BETWEEN
PREFORMED FIBER JOINTS
1/2" PREFORMED
FIBER JOINT
SEE PLANS FOR WIDTH.
BUILDING
NOTE
WALL PROJECTIONS OR SIGNS OR OTHER OBJECTS ATTACHED TO POSTS DO NOT
EXCEED 4” INTO THE PEDESTRIAN PATH BETWEEN 27” AND 80” ABOVE THE GROUND.
EXCEPTION, SIGNS OR OTHER OBJECTS ATTACHED TO POSTS MAY PROJECT INTO THE
PEDESTRIAN PATHWAY UP TO 12”, BUT IS NOT PREFERRED AND SHOULD BE LIMITED TO
4” WHERE POSSIBLE.
POST PROJECTION WALL PROJECTION
4" (MAX.)
PROTECTED ZONE
4" (DESIRABLE)
12" (MAX.)
EXPANSION JOINT
CONTROL
JOINT
1/2" PREFORMED
FIBER JOINT
EXISTING
CURB
1/2" CONTROL JOINT WITH 1/4" RD. OVER
1/2" EXPANSION JOINT WITH JOINT FILLER.
UNLESS OTHERWISE NOTED.
PROTECTED ZONE
CANE DETECTABLE
RANGE
1.5% CROSS SLOPE(2.0% MAX.)
5.0% RUNNING SLOPE(MAX.)
24"
12"
FINISHED GROUND LINE
TEMPORARY SLOPE LINE
1:1 MINIMUM
RETAINED
SOIL
SELECTED DRAINAGE AGGREGATE
WRAPPED WITH GEOTEXTILE
FILTER FABRIC
M
I N
TOP OF LEVELING PAD
BOTTOM OF LEVELING PAD
CAP BLOCK
FACE OF WALL
FINISHED GROUND LINE
GEOSYNTHETIC
REINFORCEMENT
4" DIA. (MIN.) DRAIN PIPE OUTLET
@ END OF WALL OR @ 40'
CENTERS MAX. SLOPE TO
DRAIN (1/8"/FT.)
TYPICAL MODULAR BLOCK WALL
C7
SCALE: N.T.S.
COMPACTED
BACKFILL
COMPACTED
BACKFILL
TYPICAL SECTION
NOTE:
CONTRACTOR TO SUBMIT A
SEPARATE DETAILED, SIGNED
AND SEALED, WALL DESIGN
TO ENGINEER FOR APPROVAL.
ADJACENT CONC
SIDEWALK
SEE ARCHITECTURAL PLANS FOR GUARDRAIL
WALL PROFILE
HANDICAP PARKING LAYOUT AND SIGNS
A5
SCALE: N.T.S.
PLAN
48"
4" WHITE
PAINTED
LINES
2"Ø METAL POST
OR HAT ( ) SECTION
5"Ø STEEL PIPE CONCRETE
FILLED. PRIMED AND PAINTED
YELLOW, 2 COATS
18"Ø CONCRETE
ENCASEMENT
(3000 PSI, 28 DAYS)
18"
HANDICAP
PARKING
2 SIGNS, BACK TO
BACK (ALUMINUM)
FINISHED GRADE
SIGNS AND HEIGHT TO MEET ADA
ACCESSIBILITY REQUIREMENTS.
PAINTED SYMBOL
HANDICAP PARKING SIGN IN PAVEMENT
9'
(TYP.)
9'
(TYP.)
5'
6" RAISED
CONCRETE ISLAND
WHEEL STOP, TYP
(SEE DETAIL
E9/C-504)
PAINTED SYMBOL, TYP
(SEE DETAIL)
"VAN ACCESSIBLE"
HANDICAP PARKING SIGNS
HANDICAP PARKING
SIGNS
VAN
ACCESSIBLE
"VAN ACCESSIBLE" SIGN
WHERE INDICATED
6" RAISED
CONCRETE ISLAND
M I N
4" WHITE CROSS
HATCHING AT 3'-0"
CENTER TO CENTER
ALL PAVEMENT MARKING SHALL BE 4" WHITE
CURB RAMP - PARALLEL
C5
SCALE: N.T.S.
5'
(MIN.)
L
A N
D I N
G
M
I N
M
I N
M
A X
1V:12H
(MAX.)
A
A
5'
(MIN.)
PLAN
SECTION A-A
5' (MIN.)
.0
(M
IN
.0
(M
A X
PAVEMENT
VARIABLE HEIGHT
CURB
NOTES
SEE DETAIL A1/C-505 FOR GENERAL NOTES
4"
5"
20"
2"
22"
22"
6"
10"
4"
3"
6"
2"
2"
3"
4"
4"
6"
5"
3"
CB
CB
W
W
MW
MW
T
T
F
O
I
S
W
W
W
W
W
W
F
O
CB
F
O
CO
CO
CO
CO
CO
CO
CO
W
EXISTING
INTERPRETIVE
CENTER
EXISTING
OFFICES
EXIST.
LAB
BLDG.
S
O
L
D
I
I
V
E
H
W
HWY 94
EX STORM
SHELTERS
7.29 AC
0.36 AC x 3.50 CFS/AC = 1.25(5%) CFS
6.93 AC x 1.70 CFS/AC = 11.78(95%) CFS
Q = 13.03 CFS
1.03 AC
0.37 AC x 3.50 CFS/AC = 1.30(36%) CFS
0.66 AC x 1.70 CFS/AC = 1.13(64%) CFS
Q = 2.42 CFS
4.50 AC
2.41 AC x 3.50 CFS/AC = 8.43(54%) CFS
2.09 AC x 1.70 CFS/AC = 3.56(46%) CFS
Q = 11.99 CFS
2.28 AC
0.72 AC x 3.50 CFS/AC = 2.52(32%) CFS
1.56 AC x 1.70 CFS/AC = 2.65(68%) CFS
Q = 5.17 CFS
9 6
7 6
5 6
Pr eli m inar y
Not F or C onstr ucti on
US Army Corps of Engineers ®
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R I P
T I O
N
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
DISCLAIMER OF RESPONSIBILITY
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING
CORPORATION CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY
CORPORATION CERTIFICATE LIC. NO.: 000078
Copyright © 2017 Kuhlmann design Group, Inc. All rights reserved.
C:\My Revit Local\722_DOE Interpretive Center_paul.brickler@kdginc.com.rvt
10/5/2017 4:44:25 PM
FINAL SUBMITTAL
S T
L O
U
S
T R
I C
T
R T
S
J M
U
R T
S
M
I S
S O
U R
I
H
I G
H W
S A
I N
T
C
H A
R L E
S
M
I S
S O
U
D E
P A
R T
M E
E
N E
R G
Y
L E
G A
N
A G
E M
E N
T
W E
L D
R
I N
G
S
I T
E
I N
T E
R P
R E
T I V
E
C
E N
T E
R
00 50' 100'
C-600
E X
I S
T I N
G
D R
A I N
A G
E
A R
P
CALCULATED FOR THE
15 YR. / 20 MIN. STORM EVENT
00 50' 100'
EXISTING DRAINAGE AREA MAP
A1
SCALE: 1" = 50'
File details come from the government source that posted it.