A02WISSCPlans_Part4.pdf
PDF 10 MB Posted
- Attached to
- WELDON SPRING Federal contract opportunity
- Solicitation number
- W912P9-19-R-0022_
About this file
WELDON SPRINGS PLANS 4 OF 8
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A02WISSCPlans_Part3.pdf | ||
| A02WISSCPlans_Part7.pdf | ||
| A02DOEInterpretiveCenterAdvSpecs.pdf | ||
| A02WISSCPlans_Part5.pdf | ||
| A22W912P919R0022.pdf | ||
| A02WISSCPlans_Part1.pdf | ||
| A02WISSCPlans_Part6.pdf | ||
| A02WISSCPlans_Part8.pdf | ||
| A02WISSCPlans_Part2.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F F
F F
F F
F F
F
SDSD
F F F F F
S
S
SD
S D
S D
S D
S D
D
D
S
S
D
D
G
DD D
D
D
D
F
WW
SD
D
D
BM#1
20"
2"
22"
22"
6"
10"
4"
3"
6"
2"
2"
5"
3"
SD
SD
SD
SD
SD SD SD SD SD SD SD SD SD SD
CB
CB
W
W
MW
MW
T
T
F
O
I
S
18" CMP
L
L
30" HDPE
30" HDPE
E
X
S
T
C
O
N
W
A
L
K
E
XST
C O
L
K
E
X
L
K
E
X
U
R
B
E
X
L
K
W
W
W
W
W
W
F
O
S A
N
SD
CB
E E
E
E
E
E
F
O
E
S D
SD
EX ASPH
PVMT
EX ASPH
PVMT
EX ASPH
PVMT
EX ASPH
PVMT
EX ASPH
PVMT
F
L
E X
N
C
C
U R
B
P
V
C
1 1/2" PVC
P V
C
CO
CO
CO
CO
CO
CO
CO
P V
C
P
V
C
10" PVC
P
V C
EX ASPH
PVMT
EX ASPH
PVMT
X
N
C
B
L O
C K
S
GRINDER
PUMP
ELECTRIC
PANEL
ELECTRIC XFMR
ON CONC PAD
COMM
PANEL
EX CONC
SLAB
EX GI
T 650.59
FL 646.11 (S)
FL 646.00 (N)
EX GI
T 652.84
FL 647.95
EX ROCK WALK
EX SAN CO
T 653.19
EX SAN CO
T 653.10
FL 649.40 EX SAN CO
T 652.68
FL 647.36
EX SAN CO
T 653.36
FL 649.18
EX SAN CO
T 656.91
FL 652.56
EX SAN CO
EX SAN MH
T 656.80
FL 654.75 (E)
FL 651.95 (W)
EX SAN FLOW METER VAULT
EX SAN 1K GAL. PACKAGE PLANT
EX SAN 2K GAL. DOSING TANK
EX SAN FLOW METER VAULT
EX SAN MH
T 656.24
FL 649.99
FIRE HYDRANT NOT IN SERVICE
EX
BACKFLOW
PREVENTOR
HOT BOX
EX GI
T 656.84
FL 655.44 (W)
FL 655.44 (N)
FL 655.49 (S)
ABANDONED
IN PLACE
W
EXISTING
INTERPRETIVE
CENTER
EXISTING
OFFICES
EXIST.
LAB
BLDG.
HWY 94
S
O
L
D
I
R
D
I
V
E
H
Y
NEW
INTERPRETIVE
CENTER
EX STORM
SHELTERS
0.72 AC
0.66 AC x 3.50 CFS/AC = 2.32(92%) CFS
0.06 AC x 1.70 CFS/AC = 0.10(8%) CFS
Q = 2.42 CFS
0.04 AC
0.01 AC x 3.50 CFS/AC = 0.03(26%) CFS
0.03 AC x 1.70 CFS/AC = 0.04(74%) CFS
Q = 0.08 CFS
0.03 AC
0.01 AC x 3.50 CFS/AC = 0.05(48%) CFS
0.02 AC x 1.70 CFS/AC = 0.03(52%) CFS
Q = 0.08 CFS
7.10 AC
0.21 AC x 3.50 CFS/AC = 0.75(3%) CFS
6.88 AC x 1.70 CFS/AC = 11.70(97%) CFS
Q = 12.45 CFS
6.64 AC
3.45 AC x 3.50 CFS/AC = 12.08(52%) CFS
3.19 AC x 1.70 CFS/AC = 5.41(48%) CFS
Q = 17.49 CFS
0.16 AC
0.13 AC x 3.50 CFS/AC = 0.47(86%) CFS
0.02 AC x 1.70 CFS/AC = 0.04(14%) CFS
Q = 0.51 CFS
4 6
6 6
0.02 AC
0.01 AC x 3.50 CFS/AC = 0.02(35%) CFS
0.01 AC x 1.70 CFS/AC = 0.02(65%) CFS
Q = 0.04 CFS
0.44 AC
0.44 AC x 3.50 CFS/AC = 1.53(100%) CFS
Q = 1.53 CFS
Pr eli m inar y
Not F or C onstr ucti on
US Army Corps of Engineers ®
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R I P
T I O
N
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
DISCLAIMER OF RESPONSIBILITY
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING
CORPORATION CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY
CORPORATION CERTIFICATE LIC. NO.: 000078
Copyright © 2017 Kuhlmann design Group, Inc. All rights reserved.
C:\My Revit Local\722_DOE Interpretive Center_paul.brickler@kdginc.com.rvt
10/5/2017 4:44:25 PM
FINAL SUBMITTAL
S T
L O
U I
S
T R
I C
T
R T
S
J M
U
R T
S
M
I S
S O
U R
I
H
I G
H W
S A
I N
T
C
H A
R L E
S
M
I S
S O
U
D E
P A
R T
M E
E
N E
R G
Y
L E
G A
M
N
A G
E M
E N
T
W E
L D
R
I N
G
S
I T
E
I N
T E
R P
R E
T I V
E
C
E N
T E
R
00 50' 100'
C-601
P R
O P
O S
E D
D R
A I N
A G
E
A R
P
CALCULATED FOR THE
15 YR. / 20 MIN. STORM EVENT
00 50' 100'
PROPOSED DRAINAGE AREA MAP
A1
SCALE: 1" = 50'
Pr eli m inar y
Not F or C onstr ucti on
US Army Corps of Engineers ®
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R I P
T I O
N
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
DISCLAIMER OF RESPONSIBILITY
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING
CORPORATION CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY
CORPORATION CERTIFICATE LIC. NO.: 000078
Copyright © 2017 Kuhlmann design Group, Inc. All rights reserved.
C:\My Revit Local\722_DOE Interpretive Center_paul.brickler@kdginc.com.rvt
10/5/2017 4:44:25 PM
FINAL SUBMITTAL
S T
L O
U
S
T R
I C
T
R T
S
J M
U
R T
S
M
I S
S O
U R
I
H
I G
H W
S A
I N
T
C
H A
R L E
S
M
I S
S O
U
D E
P A
R T
M E
E
N E
R G
Y
L E
G A
N
A G
E M
E N
T
W E
L D
R
I N
G
S
I T
E
I N
T E
R P
R E
T I V
E
C
E N
T E
R
C-700
G E
O T
E C
H N
I C
A L
B O
R I N
G
L
O C
A T
I O
N S
FOR
REFERENCE
ONLY
FOR REFERENCE ONLY
Pr eli m inar y
Not F or C onstr ucti on
US Army Corps of Engineers ®
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R I P
T I O
N
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
DISCLAIMER OF RESPONSIBILITY
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING
CORPORATION CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY
CORPORATION CERTIFICATE LIC. NO.: 000078
Copyright © 2017 Kuhlmann design Group, Inc. All rights reserved.
C:\My Revit Local\722_DOE Interpretive Center_paul.brickler@kdginc.com.rvt
10/5/2017 4:44:25 PM
FINAL SUBMITTAL
S T
L O
U
S
T R
I C
T
R T
S
J M
U
R T
S
M
I S
S O
U R
I
H
I G
H W
S A
I N
T
C
H A
R L E
S
M
I S
S O
U
D E
P A
R T
M E
E
N E
R G
Y
L E
G A
N
A G
E M
E N
T
W E
L D
R
I N
G
S
I T
E
I N
T E
R P
R E
T I V
E
C
E N
T E
R
C-701
G E
O T
E C
H N
I C
A L
B O
R I N
G
L
O G
S
FOR
REFERENCE
ONLY
STRUCTURAL NOTES:
GENERAL:
1. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR FLOOR AND ROOF OPENINGS,
TRENCHES, PITS, PIPE SLEEVES, CHAMFERS, ETC. WHICH ARE REQUIRED.
2. NO OPENINGS MAY BE MADE IN ANY STRUCTURAL MEMBER WITHOUT PERMISSION FROM STRUCTURAL
ENGINEER.
3. DO NOT SCALE DRAWINGS. USE THE DIMENSIONS SHOWN.
4. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR WATER/DAMPROOFING AND FIREPROOF
DETAILS AND REQUIREMENTS.
5. AT ALL TIMES, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONDITIONS OF THE
JOBSITE, INCLUDING SAFETY OF PERSONS AND PROPERTY. THE ARCHITECT'S OR ENGINEER'S
PRESENCE OR REVIEW OF WORK DOES NOT GUARANTEE THE ADEQUACY OF THE CONTRACTOR'S
MEANS OR METHODS OF CONSTRUCTION.
6. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS BEFORE FABRICATING ANY MATERIAL OR STARTING CONSTRUCTION. IF ANY CONDITIONS ARE FOUND TO BE DIFFERENT FROM
WHAT IS SHOWN, THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.
7. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS THE GENERAL CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND INSURE THE SAFETY OF THE BUILDING AND IT'S COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE INSTALLATION OF ALL SHORING, TEMPORARY BRACING, SCAFFOLDING, ETC. THAT MAY BE NECESSARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S
PROPERTY AFTER COMPLETION OF THE PROJECT.
8. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
9. SUBMITTALS PREPARED BY CONTRACTOR OR SUBCONTRACTOR SHALL BE REVIEWED AND STAMPED
BY CONTRACTOR PRIOR TO SUBMITTING TO THE STRUCTURAL ENGINEER OF RECORD. SUBMITTALS WITHOUT A CONTRACTOR'S STAMP WILL BE RETURNED WITHOUT REVIEW. SUBMITTALS SHALL BE REVIEWED WITHIN 10 WORKING DAYS AFTER BEING RECEIVED BY THE STRUCTURAL ENGINEER OF
RECORD.
10. ALL SUBMITTALS REVIEWED BY STRUCTURAL ENGINEER OF RECORD ARE REVIEWED FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITH THE INFORMATION INCLUDED IN THE CONTRACT DOCUMENTS. CONTRACTOR REMAINS RESPONSIBLE FOR ALL DIMENSIONS, SIZES, QUANTITIES, FABRICATION PROCESS AND COORDINATION OF THE WORK WITH
OTHER TRADES.
11. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS, INCLUDING CLOSING
PERMITS, FROM ST. CHARLES COUNTY, MISSOURI AND ANY OTHER APPLICABLE AGENCIES.
BUILDING CODE/DESIGN LOADS
1. GOVERNING CODE:
INTERNATIONAL BUILDING CODE - IBC 2015
RISK CATEGORY II
2. ROOF:
LIVE LOAD 20 PSF
3. SNOW:
GROUND SNOW LOAD, Pg 20 PSF IMPORTANCE FACTOR, Is 1.00 EXPOSURE FACTOR, Ce 1.00 THERMAL FACTOR, Ct 1.00 FLAT-ROOF SNOW LOAD, Pf 20 PSF
4. WIND:
BASIC WIND SPEED 115 MPH
IMPORTANCE FACTOR, Iw 1.00
EXPOSURE CATEGORY C
INT PRESSURE COEFFICIENT ± 0.18
C&C WIND PRESSURE
WALLS ± 35 PSF
PARAPETS ± 98
OVERHANGS ± 77
6. SEISMIC:
SS 0.351
S1 0.146
SDS 0.281
SD1 0.161
IMPORTANCE FACTOR, Ie 1.00
SOIL SITE CLASS C
SEISMIC DESIGN CATEGORY C
RESISTING SYSTEM (SFRS) H.1 STEEL CONCENTRICALLY BRACED FRAMES (R=3)
H.1 STEEL MOMENT FRAMES (R=3)
RESPONSE MOD. FACTOR, R 3.00
SEISMIC RESPONSE, Cs 0.094
DESIGN BASE SHEAR,V 9.4% W (KIPS)
ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE METHOD
7. SEE MECHANICAL DRAWINGS FOR ROOF TOP EQUIPMENT, LOCATIONS AND WEIGHTS.
8. LOADS ON PLAN & DETAILS ARE UNFACTORED LOADS
FOUNDATIONS:
1. FOUNDATION DESIGNS ARE BASED ON THE GEOTECHNICAL REPORT PREPARED BY: GESTRA
ENGINEERING INC., DATED DECEMBER 13, 2017. THE RECOMMENDATIONS OF THIS REPORT ARE
HEREIN MADE A PART OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
2. FOOTINGS DESIGNS ARE BASED ON AN ALLOWABLE NET BEARING CAPACITY PRESSURE OF 3000 PSF
FOR CONTINUOUS WALL FOOTINGS AND ISOLATED SPREAD FOOTINGS.
3. THE OWNER’S GEOTECHNICAL REPRESENTATIVE SHALL VERIFY THE SOIL CAPACITY DURING
CONSTRUCTION AND INFORM THE STRUCTURAL ENGINEER AS TO THE FINDINGS. IF THE BEARING CAPACITY IS LESS THAN THE LISTED AMOUNT, ADJUSTMENTS IN THE FOOTINGS SIZES MAY BE
REQUIRED. STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR SUBSURFACE CONDITIONS
ENCOUNTERED IN THE FIELD THAT ARE DIFFERENT FROM THOSE ASSUMED DURING DESIGN.
4. THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY UNUSUAL SOIL CONDITIONS
THAT ARE IN VARIANCE WITH THE GEOTECHNICAL REPORT BEFORE PROCEEDING WITH
CONSTRUCTION.
5. REMEDIATE EXISTING SOILS AS REQUIRED BY THE GEOTECHNICAL REPORT. REMOVE AND REPLACE UNSUITABLE MATERIALS IN ACCORDANCE WITH WELDON SPRING, MISSOURI SITE PROCEDURE FOR SUSPECT MATERIAL AND DEBRIS DISCOVERIES. CONTRACTOR SHALL COORDINATE WITH DEPARTMENT
OF ENERGY (DOE) SITE PERSONNEL WHERE APPLICABLE TO COMPLY WITH SITE POLICY AND
PROCEDURES. NO SOIL MAY BE TAKEN OFF-SITE.
6. PREPARE FILL AND SUBGRADE AS REQUIRED PER THE GEOTECHNICAL REPORT.
7. FOOTINGS SHALL BE POURED INTO NEATLY-FORMED TRENCHES FOR THE ENTIRE DEPTH.
8. EXCAVATIONS SHALL BE KEPT FREE OF LOOSE MATERIALS AND STANDING WATER.
9. STRUCTURAL FILL SHALL BE PLACED IN LOOSE LIFTS NOT EXCEEDING 9 INCHES IN THICKNESS AND
MECHANICALLY COMPACTED TO AT LEAST 98 PERCENT OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY, AGGREGATE BASE COURSE SHOULD BE COMPACTED TO AT LEAST 95 PERCENT MODIFIED
PROCTOR. REFER TO GEOTECHNICAL REPORT FOR ADDITIONAL INFORMATION.
10. EXTERIOR FOOTINGS SHALL BEAR AT OR BELOW A MINIMUM BEARING DEPTH OF 30-INCHES BELOW THE ADJACENT FINISHED GRADE FOR FROST PROTECTION. THICKENED SLAB EDGES FOR ALL STOOPS, CANOPIES, ETC., SHALL BE 16 INCHES (UNO).
COLD-FORMED METAL FRAMING:
1. COLD-FORMED METAL FRAMING SHALL BE FABRICATED, AND ERECTED IN ACCORDANCE WITH THE AISI "SPECIFICATIONS FOR THE DESIGN OF COLDFORMED STEEL STRUCTURAL MEMBERS," LATEST EDITION.
2. ALL LIGHT GAGE METAL FRAMING FOR EXTERIOR AND LOAD-BEARING ELEMENTS SHALL BE DESIGNED AND
DETAILED BY THE LIGHT GAGE METAL SUPPLIERS.
3. SIZE, FASTENING AND SPACING SHOWN ON DRAWINGS IS A MINUMUM. ALL SIZED, SPACING FASTENING AND BRACING SHALL BE DESIGNED AND CALLED OUT BY THE LIGHT GAGE METAL SUPPLIER AND SUBMITTED TO THE
EOR FOR REVIEW.
A. MINUMUM EXTERIOR STUD SIZE = 600 S 162-54
B. MINUMUM INTERIOR STUD SIZE = 362 S 162-43
4. DESIGNATIONS AND SIZES SHOWN REFER TO STANDARD SHAPES OF THE STEEL STUD MANUFACTURERS ASSOCIATION (SSMA). ALL STUDS SHALL HAVE FY=33 KSI MINIMUM. STUDS AND OTHER CFS SECTIONS 16 GA.
AND HEAVIER SHALL HAVE FY = 50 KSI MINIMUM.
5. ALL SHEET STEEL SHALL COMPLY WITH ASTM A1003. COATING SHALL BE G90 GALVANIZING.
6. AT LOCATIONS REQUIRING WELDING OF OR TO METAL STUDS, MINIMUM STUD THICKNESS SHALL BE 43 MIL. ALL
WELDS SHALL BE IN ACCORDANCE WITH AWS D1.3, STRUCTURAL WELDING CODE - STEEL SHEET.
7. PENETRATION OF SCREWS THROUGH JOINED MATERIALS SHOULD NOT BE LESS THAN 3 EXPOSED THREADS.
SCREWS SHOULD BE INSTALLED AND TIGHTENED IN ACCORDANCE WITH SCREW MANUFACTURER'S
RECOMMENDATIONS.
8. SCREW SPACING AND EDGE DISTANCE ON STUD ENDS AND PLATES SHALL NOT BE LESS THAN 1".
9. ALL LOAD BEARING STUDS, JOISTS, AND BRACES SHALL HAVE SOLID WEBS (UNPUNCHED).
10. PROVIDE STEEL TRACKS COMPLYING WITH ASTM C955 AT TOP AND BOTTOM OF ALL STUD WALLS, AND AT
HEADERS FOR STUD WALLS, MATCHING THICKNESS OF STUDS WITH 2" FLANG WIDTH.
11. FULL-HEIGHT DOUBLE STUDS SHALL BE PROVIDED AT THE ENDS OF PARTITIONS, AT WALL OPENINGS, AND AT
ALL OTHER LOCATIONS INDICATED IN THE STRUCTURAL DRAWINGS. WELD THE FLANGES OF DOUBLE STUDS
TOGETHER FULL HEIGHT USING 2” OF WELD AT 12” O.C., EACH SIDE.
12. PROVIDE STUD WALL BRIDGING ACCORDING TO MANUFACTURER’S RECOMMENDATIONS.
13. SPLICES IN STUDS ARE NOT PERMITTED. DO NOT CUT STUDS UNLESS SPECIFICALLY DIRECTED TO DO SO IN
THE DRAWINGS.
14. ALL LIGHT GAGE METAL FRAMING FOR EXTERIOR AND LOAD-BEARING ELEMENTS SHALL BE DESIGNED AND
DETAILED BY THE LIGHT GAGE METAL SUPPLIERS, UNLESS DESIGNATED ON DRAWINGS.
15. SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED FOR REVIEW. ALL DRAWINGS AND CALCULATIONS
SHALL BE SIGNED AND SEALED BY A MISSOURI PROFESSIONAL ENGINEER. FABRICATION SHALL NOT BEGIN UNTIL DRAWINGS AND CALCULATIONS HAVE BEEN REVIEWED AND APPROVED BY THE STRUCTURAL ENGINEER
OF RECORD.
16. THE LIGHT GAGE METAL SUPPLIER’S SHOP DRAWINGS SHALL INCLUDE DETAILS FOR VERTICAL SLIDE CLIPS AT CONTINUOUS WALLS AND VERTICAL DEFLECTION TRACKS WHERE REQUIRED AT EXTERIOR WINDOWS AND AT NON-LOAD BEARING INTERIOR WALLS. THE LOCATIONS, SIZES, AND CONNECTIONS OF ALL SLIDE CLIPS AND
DEFLECTION TRACKS SHALL BE CLEARLY INDICATED.
17. THE LIGHT GAGE METAL SUPPLIER’S SHOP DRAWINGS SHALL INCLUDE DETAILS FOR HEADERS AT ALL
OPENINGS.
18. PROVIDE 1/2" SIMPSON TITAN HD HEAVY DUTY SCREW ANCHOR, OR EQUIVELENT, @ 48" MAX SPACING AND MAX
6" FROM TRACK END AT ALL BOTTOM TRACKS.
TESTING AND SPECIAL INSPECTION
1. IN ADDITION TO THE REGULAR INSPECTIONS CONDUCTED BY THE APPLICABLE AGENCIES HAVING JURISDICTION, SPECIAL INSPECTIONS AND TESTING SERVICES SHALL BE OBTAINED AS REQUIRED BY IBC 2015 CHAPTER 17. THE OWNER SHALL BE RESPONSIBLE FOR EMPLOYING REGISTERED SPECIAL INSPECTORS FROM APPROVED TESTING AGENCIES, PER ASTM E329, TO CONDUCT INSPECTIONS FOR EACH BUILDING MATERIAL.
2. THE SPECIAL INSPECTION PROGRAM DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO COMPLY WITH THE CONTRACT DOCUMENTS. JOBSITE SAFETY AND MEANS AND METHODS OF CONSTRUCTION
ARE THE RESPONSIBILITY OF THE CONTRACTOR.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING SPECIAL INSPECTOR 72 HOURS IN ADVANCE OF REQUIRED INSPECTIONS FOR SCHEDULING PURPOSES. FAILURE TO MEET OBSERVATION SCHEDULES MAY REQUIRE REMOVAL (FOR INSPECTION PURPOSES) OF ANY FINISHES THAT HAVE BEEN SUBSEQUENTLY INSTALLED. REMOVAL AND REPLACEMENT OF ANY FINISHED AND/OR REPAIR OF FRAMING DAMAGED BY THE FINISH REMOVAL PROCESS FOR SPECIAL INSPECTIONS SHALL BE AT THE CONTRACTOR EXPENSE.
4. STRUCTURAL OBSERVATIONS CONDUCTED BY THE ENGINEER OF RECORD SHALL NOT BE CONSTRUED AS
SPECIAL INSPECTIONS.
5. SEE SPECIFICATIONS FOR CODE REQUIRED SPECIAL INSPECTION REQUIREMENTS.
CONCRETE:
1. MINIMUM CONCRETE COMPRESSIVE STRENGTH SHALL BE 5,000 PSI IN 28 DAYS FOR ALL NORMAL
WEIGHT CONCRETE.
2. ALL EXTERIOR CONCRETE EXPOSED TO FREEZE-THAW CYCLES SHALL BE AIR ENTRAINED. SEE
SPECIFICATIONS.
3. PROVIDE CONSTRUCTION OR CONTROL JOINTS IN SLAB-ON-GRADE AT A MAXIMUM SPACING OF 12 FEET
ON CENTER OR AS OTHERWISE INDICATED ON PLAN.
4. MIX DESIGN, PLACEMENT AND PROCEDURES, AND METHODS OF SAMPLING AND TESTING SHALL
CONFORM TO ASTM AND ACI STANDARDS.
REINFORCING STEEL:
1. REINFORCING STEEL SHALL CONFORM TO ASTM STANDARD A615, GRADE 60. REINFORCING TIES SHALL
BE GRADE 60.
2. ALL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN CONFORMANCE WITH THE LATEST
EDITION OF "ACI MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE STRUCTURES."
3. ALL REINFORCING SHALL BE PROPERLY SUPPORTED IN FORMS SPACED WITH NECESSARY
ACCESSORIES AND SECURELY WIRED TOGETHER.
4. ALL REINFORCING STEEL SHALL HAVE CLASS B CONTACT LAP SPLICES, PER ACI 318 EXCEPT AS NOTED.
5. PROVIDE CONCRETE PROTECTION FOR REINFORCING AS FOLLOWS:
FOOTINGS CAST AGAINST EARTH - 3"
CONCRETE EXPOSED TO EARTH OR WEATHER - 2"
FORMED SURFACES AND WALLS - 1 1/2"
SLABS - 3/4"
6. REINFORCING BARS TO BE WELDED SHALL BE ASTM 706 AND ALL WELDING TO CONFORM TO WELDING PROCEDURES SPECIFIED IN "STRUCTURAL WELDING CODE - REINFORCING STEEL" (AWS D1.4) OF THE
AMERICAN WELDING SOCIETY. DO NOT WELD ASTM A615 REBAR.
7. WELDED WIRE FABRIC SHALL BE ASTM A1064 AND SHALL BE CONTACT LAP-SPLICED TWO FULL WIRE
SPACES.
8. AT CONCRETE SLAB, PROVIDE SLAB BOLSTER HIGH CHAIRS AND #5 SUPPORT BARS AS NECESSARY TO MAINTAIN PROPER PLACEMENT OF REINFORCEMENT, PROVIDE (2) - #5 TOP x 5'-0" DIAGONALS AT
CORNERS OF OPENINGS AND RE-ENTRANT CORNERS, UNLESS NOTED OTHERWISE.
STRUCTURAL STEEL:
1. ALL STRUCTURAL STEEL SHALL BE AS FOLLOWS:
W-SHAPES Fy = 50 KSI ASTM A992 PIPE Fy = 35 KSI ASTM A53, GRADE B SQUARE AND RECTANGULAR HSS Fy = 46 KSI ASTM A500, GRADE B ANCHOR BOLTS/RODS Fy = 55 KSI ASTM F1554 CHANNELS, ANGLES, PLATES & BARS Fy = 36 KSI ASTM A36 HIGH STRENGTH BOLTS Fy = 92 KSI ASTM A325 THREADED ROD Fy = 36 KSI ASTM A36
2. ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN CONFORMANCE WITH THE LATEST EDITION OF AISC SPECIFICATIONS, "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS," AND
"SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS,".
3. ALL FIELD-BOLTED CONNECTIONS SHALL RECEIVE A MINIMUM OF TWO 3/4" DIAMETER HIGH-STRENGTH
BOLTS IN CONFORMANCE WITH ASTM A325 SPECIFICATIONS (UNLESS NOTED OTHERWISE).
4. USE PRE-QUALIFIED WELDED JOINTS IN ACCORDANCE WITH THE LATEST AISC AND AWS
SPECIFICATIONS, "STRUCTURAL STEEL WELDING CODE - STEEL" (AWS D1.1). ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS USING E70XX ELECTRODES. NON-PREQUALFIED JOINTS SHALL
BE PRE-QUALIFIED PRIOR TO FABRICATION.
5. ALL STRUCTURAL STEEL SHALL RECEIVE ONE SHOP COAT PAINT UNLESS NOTED. COLOR OF EXPOSED
STEEL BY ARCHITECT.
6. SEE ARCHITECTURAL DRAWINGS FOR MISCELLANEOUS CEILING SUPPORT ANGLES, HANGERS AND
OTHER ITEMS NOT SHOWN IN STRUCTURAL DRAWINGS.
7. DESIGN CONNECTIONS NOT DETAILED ON THESE DRAWINGS UNDER DIRECT SUPERVISION OF A PROFESSIONAL ENGINEER, EXPERIENCED IN THE DESIGN OF THIS WORK, AND LICENSED IN THE STATE
OF MISSOURI.
8. IF BEAM REACTION IS NOT INDICATED, DESIGN CONNECTION FOR MINIMUM 10 k ASD REACTION
9. CONTRACTOR SHALL COORDINATE WITH THE STRUCTURAL DRAWINGS AND OTHER DISCIPLINES FOR
OPENINGS.
10. ALL BOLTED SLIP CONNECTIONS WITH LONG-SLOTTED HOLES TO BE FINGER-TIGHT. MAR THE BOLT
THREADS AND TACK WELD THE NUT TO THE BOLT.
11. STRUCTURAL STABILITY: THE ENTIRE ROOF AND/OR FLOOR DECKING MATERIALS MUST BE FULLY
ERECTED AND CONNECTED TO THE SUPPORTING STEEL BEFORE TEMPORARY, ERECTION BRACING IS
REMOVED.
METAL DECK:
1. METAL DECK SHALL COMPLY WITH THE REQUIREMENTS OF THE STEEL DECK INSTITUTE "SDI SPECIFICATIONS AND COMMENTARY" AND "CODE OF RECOMMENDED STANDARD PRACTISCE" AS WELL
AS THE PROJECT SPECIFICATIONS.
2. SEE PLANS FOR DECK TYPES, GAGES, AND ATTACHMENTS.
3. DECK SHALL BE CONTINUOUS OVER THREE SPANS, UNLESS NOTED OTHERWISE.
4. DO NOT HANG OR ATTACH DUCTS, PIPES, CEILING, SPRINKLERS, ETC. FROM METAL DECK.
5. METAL DECK SHALL HAVE A MINIMUM YIELD STRENGTH OF 33KSI.
6. PROVIDE L3x3x1/4 MINIMUM AT ALL UNSUPPORTED EDGES OF DECK AND AROUND ROOF PERIMETER, UNLESS NOTED OTHERWISE.
STEEL JOISTS:
1. DESIGN IN ACCORDANCE WITH SJI AND PROJECT SPECIFICATIONS. CONFORM TO THE REQUIREMENTS
OF OSHA 29 CFR PART 1926 FOR THE FOLLOWING:
BOLTED CONNECTIONS.
BOTTOM CHORD EXTENSIONS AT COLUMN CENTERLINES.
COLUMN – JOIST STABILITY.
ERECTION STABILITY BRIDGING.
2. STEEL JOIST MANUFACTURER SHALL PROVIDE DESIGN CALCULATIONS AND SHOP DRAWINGS SEALED
BY A REGISTERED MISSOURI PROFESSIONAL ENGINEER.
3. ERECT IN ACCORDANCE WITH AISC, SJI, AND PROJECT SPECIFICATIONS. DO NOT ERECT DAMAGED
JOISTS. DO NOT FIELD CUT, DRILL, OR MODIFY JOISTS.
4. WELD JOISTS TO SUPPORTS PER SJI, UNLESS NOTED OTHERWISE.
5. PROVIDE SLOP SHOES OR BEARINGS AS REQUIRED FOR LEVEL BEARING ON SUPPORTS.
6. PROVIDE BOLTED JOIST CONNECTIONS FOR ALL JOIST-ON-COLUMN CENTERLINES.
7. PROVIDE AND ANCHOR BRIDGING PER SJI. EXTEND AND CONNECT BRIDGING TO ADJACENT BEAMS
AND/OR WALLS.
8. BRIDGING SHALL BE COMPLETELY ERECTED AND JOISTS ALIGNED BEFORE ANY CONSTRUCTION LOADS
ARE PLACED ON JOISTS.
9. PROVIDE CEILING EXTENSIONS WHERE CEILINGS ARE ATTACHED DIRECTLY TO BOTTOM CHORD OF
JOISTS.
10. DO NOT WELD BOTTOM CHORD OF JOISTS TO COLUMNS UNLESS NOTED ON DRAWINGS.
11. DESIGN JOISTS FOR NET WIND UPLIFT OF 27 PSF.
12. PROVIDE ADDITIONAL BRIDGING WHERE REQUIRED FOR UPLIFT.
ACTIVITY/TYPE OF SPECIAL
INSPECTION
DESCRIPTION CONTINUOUS PERIODIC REFERENCE
DATE
COMPLETED
GENERAL
SPECIAL
INSPECTOR/LABORATORY
QUALIFICATIONS
SOIL BEARING CAPACITY
CONCRETE
INSPECTION OF REINFORCING STEEL
DESIGN MIX
CONCRETE TESTS AND SAMPLING
CONCRETE PLACEMENT
DOCUMENTATION OF QUALIFICATIONS FOR ALL
SPECIAL INSPECTORS AND LABORATORIES
PROVIDING SERVICES DESCRIBED IN THIS
SECTION.
CONTRACTOR'S GEOTECHNICAL ENGINEER TO
CERTIFY SOIL BEARING CAPACITY.
VERIFY GRADE AND PLACEMENT.
VERIFY DESIGN MIX PLACEMENT.
AT THE TIME FRESH CONCRETE IS SAMPLED TO
FABRICATE SPECIMENS FOR STRENGTH TESTS,
PERFORM SLUMP, AIR CONTENT, AND
TEMPERATURE TESTS.
INSPECTION OF CONCRETE PLACEMENT FOR
PROPER APPLICATION TECHNIQUES.
N.A. N.A. ASTM E329
----- X
X
X
ACI 318
ACI 318
X
X
ASTM C172,
ASTM C31,
ACI 318
ACI 318
VERIFY MATERIALS OF HIGH-STRENGTH BOLTS,
NUTS, WASHERS AND THREADED RODS AS
CONFORMING TO ASTM STANDARDS SPECIFIED IN
THE CONSTRUCTION DOCUMENTS.
MATERIAL VERIFICATION -
CONNECTIONS
----- X
APPLICABLE
ASTM
MATERIAL
SPECIFICATION
STRUCTURAL STEEL
VERIFY MATERIALS OF STRUCTURAL STEEL AS
CONFORMING TO ASTM STANDARDS SPECIFIED IN
THE CONSTRUCTION DOCUMENTS.
MATERIAL VERIFICATION -
STRUCTURAL STEEL
----- X
ASTM A 6 OR
A 568
REVIEW IDENTIFICATION MARKINGS, CERTIFICATE
OF COMPLIANCE AND WELDER CERTIFICATIONS.
WELD MATERIALS AND WELDER
CERTIFICATION
----- X AWS D1.1
INSPECTION AND TESTING OF SINGLE PASS FILLET
WELDS LESS THAN OR EQUAL TO 5/16"
WELDS ----- X AWS D1.1
INSPECTION AND TESTING OF SINGLE PASS FILLET
WELDS GREATER THAN 5/16"
WELDS ----- X AWS D1.1
OPEN WEB STEEL JOIST
STANDARD BRIDGINGBRIDGING ----- X SJI 2207.1
END CONNECTIONS - WELDING OR BOLTEDINSTALLATION -----X SJI 2207.1
BRIDGING THAT DIFFERS FROM SJI
SPECIFICATIONS LISTED IN SECTION 2207.1
BRIDGING X
IBC INTERNATIONAL BUILDING CODE
IN INCH
LBS POUNDS
LLV LONG LEG VERTICAL
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL/ELECTRICAL/PLUMBING
NA NOT APPLICABLE
OC ON CENTER
PL PLATE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
QTY QUANTITY
REBAR REINFORCING STEEL BARS
REINF REINFORCE(D), (ING), (MENT)
REQD REQUIRED
RET RETURN
REV REVISION
SCHED SCHEDULE
SDI STEEL DECK INSTITUTE
SJI STEEL JOIST INSTITUTE
SIM SIMILAR
SQ SQUARE
SQ IN SQUARE INCH
SQ FT SQUARE FOOT
STL STEEL
STRUC STRUCTURAL
SYMM SYMMETRICAL
T THICKNESS
T/STL TOP OF STEEL
T/FTG TOP OF FOOTING, TOP OF FOUNDATION
T/WALL TOP OF WALL
T&B TOP AND BOTTOM
THRU THROUGH
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
W/ WITH
WP WORKING POINT
WWF WELDED WIRE FABRIC
VB VERTICAL BRACE
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ARCH ARCHITECT (URAL)
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
AWS AMERICAN WELDING SOCIETY
B/FTG BOTTOM OF FOOTING
BP BASE PLATE
CFS COLD FORMED STEEL
CL CENTER LINE
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS (ATION)
DTL DETAIL
EA EACH
EF EACH FACE
ELEV ELEVATOR, ELEVATION
EOD EDGE OF DECK
EW EACH WAY
FT FEET, FOOT, FLOOR TRUSS
FTG FOOTING
GA GAGE
STRUCTURAL ABBREVIATIONS
DWG(S) DRAWING(S)
EMBED EMBEDMENT
k KIP (1000 LB)
WWR WELDED WIRE REINFORCEMENT
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
S-001
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T M
M J
J A
S
K D
G
A C
A
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S
A
IN
T C
H A
R L
E S
M
IS
S
O U
R I
S T
R U
C T
U R
A L G
E N
E R
A L N
O T
E S
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
H
H
G
G
F
F
D
D
E
E
C
C
B
B
6.86.8
9.59.5
F.3 E.1 D.2 C.5
E.8
I
I
A
A
E.7 E.3 D.7 D.3
4.9
= 33 PSF SNOW LOAD
= 42 PSF SNOW LOAD
= 36 PSF SNOW LOAD
= 62 PSF SNOW LOAD
5' - 0"
8' - 0"8' - 0"
8' - 0"
8' - 0"
8' - 0"8' - 0"
12' - 0"
12' - 0"
12' - 0"
12' - 0" 8' - 0" 8' - 0"
8' - 0"
DRIFT LOADING LEGEND
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
S-002
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T M
M J
J A
S
K D
G
A C
A
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S A
IN
T
C H
A R
L E
S M
IS
S
O U
R I
R O
O F
L O
A D
IN
G
P L A
N
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
SCALE: 3/32" = 1'-0"
DRIFT LOADING PLAN
16'8' 32'0
SCALE: 3/32" = 1'-0"
Plan
North TrueNorth
H G F E
6.8
9.59.5
F.3 E.1E.8
2' - 9"19' - 5"6' - 7"14' - 6"31' - 5"34' - 9"9' - 0"
28' - 9"45' - 11"34' - 9"
S-501
S-501
FOUNDATION PLAN NOTES:
1. SEE FOOTING SCHEDULE FOR FOOTING SIZES AND REINFORCEMENT.
2. ALL COLUMN FOOTINGS AND PILASTERS ARE ON COLUMN GRID CENTERS, UNLESS NOTED OTHERWISE.
3. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR LOCATIONS, SIZES, AND ELEVATIONS OF
UNDERSLAB UTILITIES WHICH MAY PENETRATE SLABS, WALLS, AND FOOTINGS.
4. DO NOT CUT REINFORCEMENT FOR PENETRATIONS.
5. SEE SHEET S-001 FOR ADDITIONAL GENERAL FOUNDATION NOTES.
6. FINISHED SLAB ELEVATION = 0'-0" UNLESS NOTED OTHERWISE (CIVIL ELEVATION = 659.15')
7. SEE ARCH DWGS FOR ALL DIMENSIONS NOT SHOWN. CONTRACTOR SHALL VERIFY ALL DIMENSIONS
PRIOR TO CONSTRUCTION AND NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES IMMEDIATELY.
8. BOTTOM OF STEM WALL FOOTING = -3'-6" UNLESS NOTED OTHERWISE
9. TOP OF STEM WALL = +0'-6" UNLESS NOTED OTHERWISE
10. TOP OF STEM WALL = 0'-0" @ STOREFRONT
11. TOP OF STEM WALL = -0'-5" @ DOOR
12. SEE 7/S-302 FOR STEPFOOTING DETAL
5" CONCRETE SLAB ON GRADE REINFORCED
WITH 6x6-W2.1xW2.1 W.W.R. OVER
10 MIL. VAPOR BARRIER OVER
6" GRANULAR FILL
FINISH FLOOR ELEVATION = 0'-0"
(CIVIL ELEVATION = 659.15')
-4
F5.
-5
F5.
-4
F4.
-3' - 6"
F4.0
-3
F4.
-3
F4.
-1
0"
F5.
-1
0"
F5.
-3
F5.
-3' - 8"F5.0
-3
F5.
-3
F5.
-3
F5.
-3' - 8"F5.0
-3
F5.
-3' - 8"
F5.0
-1
0"
F5.
-1
0"
F5.
-1
0"
F6.
-1
0"
F6.
-1
0"
F5.
-1
0"
F6.
-1
0"
F5.
-3
F5.
0A
-3
F5.
-3
F4.
-3
F5.
0A
-3
F5.
0A
-3
F4.
-1
0"
F6.
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
9' - 0"1' - 9 1/2"
S-303
S-303
S-303
S-303
S-303
S-303
1' - 0"6"20' - 0"1' - 0"20' - 0"4' - 5"
E.7
E.3
6' - 1"12' - 2"
D.7
4.9
S-303
3' - 7 3/4"
S-406
-3
F4.
CONCRETE WALL
OF PLANTER
S-303
S-302
S-302
S-302
S-302
S-302
S-302
16' - 0" 20' - 0"
STEP
FOOTING
S T
E P
F O
O T
IN
G
S T
E P
F O
O T
IN
G
STEP
FOOTING
B/FTG = -3' - 6"
B/FTG = -4' - 4"
B/FTG = -5' - 0" B/FTG = -4' - 6"
B/FTG = -3' - 6"
1' - 9 1/2"
4 3/8"
S-302
B/FTG = -4' - 6"
B/FTG = -5' - 0"
B/FTG = -4' - 4"
3' - 8 3/8"
/8
7' - 11 3/4"12' - 0"
3 3/4"
/2
/4
/4
LACATIONS
1'-3 1/4"
TYP. 4
LOCATIONS
3'-4"
TYP. 4
1' - 0"
1' - 0"
1' - 0"
4 3/8"
FOOTING DESIGNATION
F3.
'-0
INDICATES BOTTOM
OF FOOTING
INDICATES SIZE
OF FOOTING
SEE 8/S-302 FOR TYPICAL FOOTING DETAIL
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
S-101
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T M
M J
J A
S
K D
G
A C
A
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S
A
IN
T C
H A
R L
E S
M
IS
S
O U
R I
F O
U N
D A
T
IO
N P
L A
N
A R
E A
A
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
SCALE: 1/8" = 1'-0"1
1ST FLOOR - AREA 'A'
AREA
A
KEY PLAN - AREA 'A'
Plan North
TrueNorth
SPREAD FOOTING SCHEDULE
Type Mark Length Width Thickness REINFORCING
F4.0 4' - 0" 4' - 0" 1' - 0" (5) - #6 EACH WAY
F5.0 5' - 0" 5' - 0" 1' - 2" (6) - #6 EACH WAY
F5.0A 5' - 0" 5' - 0" 2' - 6" (6) - #6 EACH WAY TOP & BOTTOM
F6.0 6' - 0" 6' - 0" 1' - 2" (7) - #6 EACH WAY
8'4' 16'0
SCALE: 1/8"=1'-0"
DE C B
6.8
9.5
E.1 D.2 C.5
6' - 9"38' - 0"19' - 5"14' - 4"8' - 7"20' - 2"2' - 9"
1' - 0"38' - 0"33' - 9"28' - 9"
S-501
S-501
S-501
FOUNDATION PLAN NOTES:
1. SEE FOOTING SCHEDULE FOR FOOTING SIZES AND REINFORCEMENT.
2. ALL COLUMN FOOTINGS AND PILASTERS ARE ON COLUMN GRID CENTERS, UNLESS NOTED OTHERWISE.
3. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR LOCATIONS, SIZES, AND ELEVATIONS OF
UNDERSLAB UTILITIES WHICH MAY PENETRATE SLABS, WALLS, AND FOOTINGS.
4. DO NOT CUT REINFORCEMENT FOR PENETRATIONS.
5. SEE SHEET S0-01 FOR ADDITIONAL GENERAL FOUNDATION NOTES.
6. FINISHED SLAB ELEVATION = 0'-0" UNLESS NOTED OTHERWISE (CIVIL ELEVATION = 659.15')
7. SEE ARCH DWGS FOR ALL DIMENSIONS NOT SHOWN. CONTRACTOR SHALL VERIFY ALL DIMENSIONS
PRIOR TO CONSTRUCTION AND NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES IMMEDIATELY.
8. BOTTOM OF STEM WALL FOOTING = -3'-6" UNLESS NOTED OTHERWISE
9. TOP OF STEM WALL = +0'-6" UNLESS NOTED OTHERWISE
10. TOP OF STEM WALL = 0'-0" @ STOREFRONT
11. TOP OF STEM WALL = -0'-5" @ DOOR
12. SEE 7/S302 FOR STEP FOOTING DETAIL
5" CONCRETE SLAB ON GRADE REINFORCED
WITH 6x6-W2.1xW2.1 W.W.R. OVER
10 MIL. VAPOR BARRIER OVER
6" GRANULAR FILL
FINISH FLOOR ELEVATION = 0'-0"
(CIVIL ELEVATION = 659.15')
-5' - 2"
F5.0
-5
F5.
-3
F5.
-1
0"
F6.
-3
F5.
-3' - 6"
F4.0
-3
F5.
-1
0"
F6.
-1
0"
F6.
-3
F4.
-1
0"
F6.
-1
F4.
-3
F5.
-3' - 8"
F5.0
-3
F5.
-4
F5.
-1
0"
F5.
-3
F5.
0A
-3
F5.
0A
-3
F5.
0A
-3
F4.
-3
F4.
-3
F4.
-3
F5.
E.3 D.7 D.3
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-303
S-302
S-303
S-303
1' - 0"
1' - 11" 10' - 4"
4.9
12' - 2"6' - 1"6' - 1"
S-303
S-406
S T
E P
F O
O T
IN
G
STEP
FOOTING
CONCRETE WALL
OF PLANTER
SEE CIVIL FOR WALL
ELEVATIONS AND LOCATION
SLOPE
SEE ARCH.
SLOPE
SEE ARCH. 5
S-302
S-302
S-302
S-302
S-302
10' - 0"
S T
E P
F O
O T
IN
G
STEP
FOOTING
B/FTG = -3' - 6"
B/FTG = -5' - 0"
B/FTG = -3' - 6"
B/FTG = -3' - 6"
B/FTG = -4' - 6"
B/FTG = -4' - 6"
B/FTG = -3' - 6"
S-303
/2
2' - 0" 1' - 4"
1' - 4"
B/FTG = -5' - 0"
4' - 3"14' - 0"1' - 0"14' - 6"
8' - 4 3/8"
B/FTG = -5' - 0"
w A
R C
H
/8
C O
O R
D
COORD. w/ ARCH.
18' - 3 3/8" 5
S-302
8' - 4 3/8"
8' - 4 3/8"
S-303
8' - 4 3/8"
S-303
4 1/4"
3' - 4"8' - 10 1/2"
/8
/4
/8
/8
/8
/8
W H
E R
E I N
T E
R
IO
R S
L A
B S
L O
P E
S T
O E
X T
E R
IO
R
T O
P O
F S
T E
M W
A L L
D
O O
R S
FOOTING DESIGNATION
F3.
'-0
INDICATES BOTTOM
OF FOOTING
INDICATES SIZE
OF FOOTING
SEE 8/S-302 FOR TYPICAL FOOTING DETAIL
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
S-102
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T M
M J
J A
S
K D
G
A C
A
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S
A
IN
T C
H A
R L
E S
M
IS
S
O U
R I
F O
U N
D A
T
IO
N P
L A
N
A R
E A
B
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
SCALE: 1/8" = 1'-0"1
1ST FLOOR - AREA 'B'
AREA
B
KEY PLAN - AREA 'B'
Plan North
TrueNorth
SPREAD FOOTING SCHEDULE
Type Mark Length Width Thickness REINFORCING
F4.0 4' - 0" 4' - 0" 1' - 0" (5) - #6 EACH WAY
F5.0 5' - 0" 5' - 0" 1' - 2" (6) - #6 EACH WAY
F5.0A 5' - 0" 5' - 0" 2' - 6" (6) - #6 EACH WAY TOP & BOTTOM
F6.0 6' - 0" 6' - 0" 1' - 2" (7) - #6 EACH WAY
ROOF FRAMING PLAN NOTES:
1. METAL ROOF DECK SHALL BE 1.5B 20 GA. WIDE RIB METAL DECK, 3 SPANS MINIMUM, SEE TYPICAL
DETAILS FOR ATTACHMENT TO STRUCTURE.
2. INDICATES DECK SPAN DIRECTION.
3. LOW ROOF T/STL ELEVATION = VARIES
4. HIGH ROOF T/STL ELEVATION = VARIES
5. SEE GENERAL NOTES S-001 FOR ADDITIONAL PROJECT REQUIREMENTS.
6. VB-X INDICATES VERTICAL BRACE LOCATION.
7. * COORDINATE THE SIZE AND LOCATION OF MECHANICAL OPENINGS WITH MECHANICAL CONTRACTOR.
8. INDICATES MOMENT CONNECTION REQUIRED, SEE 3/S-402.
9. INDICATES DRAG CONNECTION REQUIRED, SEE 4/S-502.
10. FOR SUPPORT OF ALL ROOF TOP EQUIPMENT SHOWN ON PLAN, PROVIDE A STEEL ANGLE FRAME
AROUND OPENINGS AND PERIMETERS, SEE 5/S402.
11. STRUCTURE IS DESIGNED FOR THE FOLLOWING MECHANICAL UNIT WEIGHTS, WHICH INCLUDES CURB
WEIGHT. COORDINATE WITH MECHANICAL:
DOAS-1 = 5,000 lbs. MAX.
CU-1 = 1,100 lbs. MAX.
CU-2 = 1,500 lbs. MAX.
12. SEE MECHANICAL ROOF PLANS FOR EXHAUST FANS AND ALL OTHER ROOF TOP EQUIPMENT NOT
SHOWN ON PLAN.
13. GENERAL CONTRACTOR TO COORDINATE FINAL UNIT LOCATIONS, SIZES, AND WEIGHTS AND NOTIFY
STRUCTURAL ENGINEER IMMEDIATELY OF ANY DISCREPANCIES.
14. * - COORDINATE OPENING SIZE IN DECK WITH CONTRACTOR INSTALLING THROUGH DECK ITEM. SEE
DETAIL 5/S-402.
H G F E
6.8
9.59.5
F.3 E.1E.8I
S-501
S-501
S-404
E.7 E.3 D.7
S-404
S-404
28' - 9"45' - 11"34' - 9"10' - 6"
W
X
T
/1
2' - 9"19' - 5"6' - 7"14' - 6"31' - 5"34' - 9"10' - 6"
5 EQUAL SPACES
6' - 1"12' - 2"
S-404
S-404
6"
W
X
T
/1
T 12' - 5 3/16"
W21X44
T 13' - 4 11/16"
T 12' - 5 3/16" W21X44 T 13' - 4 11/16"
T 13' - 4 11/16"
W18X35
T 12' - 9 1/2"
W
X
T
/1
W
X
T
/1
W
X
T
/8
T 15' - 0 7/8"
W21X48
T 14' - 4 3/16" T 14' - 4 3/16"
W21X48
T 13' - 4 11/16"
T 15' - 0 7/8" W21X48 T 14' - 4 3/16" T 14' - 4 3/16" W21X48 T 13' - 4 11/16"
W
X
T
/1
W
X
T
/1
T 14' - 4 3/16"
W21X44
T 13' - 4 11/16"
T 14' - 4 3/16"
W18X40
T 13' - 8 5/16" T 13' - 3 1/16"
W18X35
T 12' - 10 3/16"
W
X
T
/1
W
X
T
/1
T 13' - 4 11/16"
W21X50
T 12' - 9 1/2"
W
X
T
W
X
T
K
K
K
K
K
K
K
K
K
K
K
W
X
T
/1
K
K
K
K
K
K
C S
K
C S
K
K
K
K
K
K
K
C S
K
C S
K
C S
K
C S
K
K
K
K
C S
K
K
K
K
C S
T 13' - 7 3/16" W21X44 T 13' - 7 3/16"
W
X
T
/1
T 13' - 8 5/16"
W18X35
T 13' - 3 1/16"
W16X26
T 13' - 0"
W16X26
T 13' - 0"
VB-1
VB-2
L5x5x3/8 @ UNIT
PERIMETER
BETWEEN JOIST
DOAS-1
S-405
S-405
E O
D
F R
A M
IN
G
T
Y P
E O
D T
O B
N T
E R
L
IN
E O
F
CU-1
CU-2
S-406
S-405
S-404
S-404
S-404
SIM. SIM.
SIM.
5' - 4 3/4" 4 SPACES @ 6'-0" = 24' - 0" 5' - 4 1/4" 4' - 11 5/8" 6 SPACES @ 6'-0" = 36' - 0" 4' - 11 3/8"
4' - 11 5/8" 6 SPACES @ 6'-0" = 36' - 0" 4' - 11 3/8"
4' - 11 5/8" 6 SPACES @ 6'-0" = 36' - 0" 4' - 11 3/8"
SIM.
L5x5x3/8 @ UNIT
PERIMETER
BETWEEN JOIST
HSS 2 1/2x2 1/2x1/4
@ UNIT
PERIMETER
BETWEEN JOIST
SEATS
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
S-201
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T M
M J
J A
S
K D
G
A C
A
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S
A
IN
T C
H A
R L
E S
M
IS
S
O U
R I
L O
W F
R A
M
IN
G P
L A
N
A R
E A
A
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
AREA
A
KEY PLAN - AREA 'A'
Plan North
TrueNorth
SCALE: 1/8" = 1'-0"1
LOW ROOF T/STEEL - AREA 'A'
8'4' 16'0
DOAS-2
DETAILS FOR ATTACHMENT TO STRUCTURE.
2. INDICATES DECK SPAN DIRECTION.
3. LOW ROOF T/STL ELEVATION = VARIES
4. HIGH ROOF T/STL ELEVATION = VARIES
5. SEE GENERAL NOTES S-001 FOR ADDITIONAL PROJECT REQUIREMENTS.
6. VB-X INDICATES VERTICAL BRACE LOCATION.
7. * COORDINATE THE SIZE AND LOCATION OF MECHANICAL OPENINGS WITH MECHANICAL CONTRACTOR.
8. INDICATES MOMENT CONNECTION REQUIRED, SEE 3/S-402.
9. INDICATES DRAG CONNECTION REQUIRED, SEE 4/S-502.
10. FOR SUPPORT OF ALL ROOF TOP EQUIPMENT SHOWN ON PLAN, PROVIDE A STEEL ANGLE FRAME
AROUND OPENINGS AND PERIMETERS, SEE 5/S402.
11. STRUCTURE IS DESIGNED FOR THE FOLLOWING MECHANICAL UNIT WEIGHTS, WHICH INCLUDES CURB
WEIGHT. COORDINATE WITH MECHANICAL:
DOAS-2 = 5,000 lbs. MAX.
CU-3 = 1,100 lbs. MAX.
12. SEE MECHANICAL ROOF PLANS FOR EXHAUST FANS AND ALL OTHER ROOF TOP EQUIPMENT NOT
SHOWN ON PLAN.
13. GENERAL CONTRACTOR TO COORDINATE FINAL UNIT LOCATIONS, SIZES, AND WEIGHTS AND NOTIFY
STRUCTURAL ENGINEER IMMEDIATELY OF ANY DISCREPANCIES.
14. * - COORDINATE OPENING SIZE IN DECK WITH CONTRACTOR INSTALLING THROUGH DECK ITEM. SEE
DETAIL 5/S-402.
DE C B
6.8
9.5
E.1 D.2 C.5 A
S-501
S-501
S-501
S-404
D.7 D.3
4.9
8' - 11"38' - 0"19' - 5"14' - 4"28' - 9"2' - 9"
8' - 11"38' - 0"33' - 9"28' - 9"
L5x5x3/8 @ UNIT
PERIMETER BETWEEN
JOIST
HSS 2 1/2x2 1/2x1/4 @
UNIT PERIMETER
BETWEEN JOIST SEATS
12' - 2"6' - 1"
S-404
S-404
T 12' - 9 1/2"
W18X35
T 13' - 4 11/16"
W
X
T
/1
W
X
T
/1
W
X
T
/1
T 13' - 4 11/16"
W18X35
T 14' - 1 1/8" T 14' - 1 1/8"
W18X35
T 14' - 10 5/8"
W
X
T
/8
T 13' - 2 9/16"
W18X35
T 13' - 8 1/4" T 14' - 1 1/8"
W18X35
T 14' - 10 5/8"T 12' - 8 13/16"
W18X35
T 13' - 2 9/16"
T 12' - 9 1/2"
W21X68
T 13' - 4 11/16"
W
X
T
W
X
T
W
X
T
/8
K
K
K
K
K
C S
K
C S
K
C S
K
C S
K
K
K
K
K
C S
K
C S
K
K
K
K
K
T 13' - 8 1/4"
W18X35
T 14' - 1 1/8"
W16X26
T 13' - 0"
W16X26
T 13' - 0"
VB-3
VB-4
VB-5
E O
D
CU-3
S-405
S-405
S-405
FRAMING, TYP.
EOD TO BE
CENTERLINE OF
W
X
T
/1
W21X44
T 13' - 7 3/16"
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
S-202
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T M
M J
J A
S
K D
G
A C
A
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S
A
IN
T C
H A
R L
E S
M
IS
S
O U
R I
L O
W F
R A
M
IN
G P
L A
N
A R
E A
B
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
AREA
B
KEY PLAN - AREA 'B'
Plan North
TrueNorth
SCALE: 1/8" = 1'-0"1
LOW ROOF T/STEEL - AREA 'B'
DOAS-2
DETAILS FOR ATTACHMENT TO STRUCTURE.
2. INDICATES DECK SPAN DIRECTION.
3. LOW ROOF T/STL ELEVATION = VARIES
4. HIGH ROOF T/STL ELEVATION = VARIES
5. SEE GENERAL NOTES S0-01 FOR ADDITIONAL PROJECT REQUIREMENTS.
6. VB-X INDICATES VERTICAL BRACE LOCATION.
7. * COORDINATE THE SIZE AND LOCATION OF MECHANICAL OPENINGS WITH MECHANICAL CONTRACTOR.
8. INDICATES MOMENT CONNECTION REQUIRED, SEE 3/S-402.
9. INDICATES DRAG CONNECTION REQUIRED, SEE 4/S-502.
10. FOR SUPPORT OF ALL ROOF TOP EQUIPMENT SHOWN ON PLAN, PROVIDE A STEEL ANGLE FRAME
AROUND OPENINGS AND PERIMETERS, SEE 5/S402.
11. SEE MECHANICAL ROOF PLANS FOR EXHAUST FANS AND ALL OTHER ROOF TOP EQUIPMENT NOT
SHOWN ON PLAN.
12. GENERAL CONTRACTOR TO COORDINATE FINAL UNIT LOCATIONS, SIZES, AND WEIGHTS AND NOTIFY
STRUCTURAL ENGINEER IMMEDIATELY OF ANY DISCREPANCIES.
13. * - COORDINATE OPENING SIZE IN DECK WITH CONTRACTOR INSTALLING THROUGH DECK ITEM. SEE
DETAIL 5/S-402.
H G F E
6.8
9.59.5
F.3 E.1E.8I
S-501
S-501
S-404
E.7 E.3 D.7
S-404
S-404
S-404
28' - 9"45' - 11"34' - 9"10' - 6"
2' - 9"19' - 5"6' - 7"14' - 6"31' - 5"34' - 9"10' - 6"
6 EQUAL SPACES 8 EQUAL SPACES
6 EQUAL SPACES 8 EQUAL SPACES
6 EQUAL SPACES
6 EQUAL SPACES 4 EQUAL SPACES 4 EQUAL SPACES
6' - 1"12' - 2"
S-404
S-404
S-404
S-404
S-404
E O
D
E O
D
EOD
6"
T 19' - 5 1/2"
W18X71
T 20' - 5"
T 20' - 4 13/16"
W12X58
T 19' - 5 1/2" T 19' - 5 1/2"
W18X71
T 20' - 5"
T 20' - 4 13/16"
W12X58
T 19' - 5 1/2" T 19' - 5 1/2"
W18X71
T 20' - 5"
T 20' - 4 13/16"
W12X58
T 19' - 5 1/2" T 19' - 5 1/2"
W18X71
T 20' - 5"
T 20' - 4 13/16"
W12X58
T 19' - 5 1/2" T 19' - 5 1/2"
W18X71
T 20' - 5"
T 20' - 4 13/16"
W12X58
T 19' - 5 1/2" T 19' - 5 1/2"
W18X71
T 20' - 5"
T 20' - 4 13/16"
W12X58
T 19' - 5 1/2" T 19' - 5 1/2"
W16X36
T 20' - 1 3/8"
T 19' - 5 1/2"
W14X38
T 20' - 1 3/8"
W
X
T
/1
W
X
T
/1
W
X
T
/1
W
X
T
/1
W
X
T
/2
W
X
T
/2
W
X
T
/2
T 20' - 6 5/8"
W16X26
T 20' - 11 1/2"
T 20' - 6 5/8"
W14X26
T 20' - 11 1/2"
W
X
T
/8
W
X
T
/1
W
X
T
/1
W
X
T
/1
W
X
T
/1
W
X
T
/1
W
X
T
/1
W
X
T
/1
W
X
T
/1
W
X
T
/1
W
X
T
/1
W
X
W
X
W
X
W
X
W
X
W
X
W
X
W
X
T
/8
W
X
T
/8
W
X
T
W
X
T
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
T 20' - 1 3/8"
W14X26
T 20' - 6 5/8"
T 20' - 1 3/8"
W16X26
T 20' - 6 5/8"
T 20' - 4 13/16"
W12X58
T 19' - 5 1/2"
T 20' - 4 13/16"
W12X58
T 19' - 5 1/2"
W
X
T
W
X
T
W
X
W
X
W
X
W
X
W
X
W
X
W
X
W
X
W
X
W
X
E O
D
E O
D
E O
D
E O
D
E O
D
E O
D
VB-1
VB-2
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
6 EQUAL SPACES 8 EQUAL SPACES
K
K
K
K
K
K
K
K
K
K
K
K
K
S-405
S-405
EOD
5 3/8"
EOD
5 3/8"
EOD
5 3/8"
S-405
S-404
SIM.
S-404
S-404
SIM.
S-404
S-404
S-404
S-404
S-404
S-404
W12X58
W12X58
W12X58
W12X58
W12X58
W12X58
W12X58
W12X58
S-405
TYP. 5
LOCATIONS
EOD
6" SIM.
S-404
S-404
SIM.
SIM.
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
S-203
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T M
M J
J A
S
K D
G
A C
A
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S A
IN
T
C H
A R
L E
S M
IS
S
O U
R I
H
IG
H F
R A
M
IN
G P
L A
N
A R
E A
A
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
AREA
A
KEY PLAN - AREA 'A'
Plan
North TrueNorth
SCALE: 1/8" = 1'-0"
HIGH ROOF T/STEEL - AREA 'A'
DE C B
6.8
9.5
E.1 D.2 C.5 A
S-501
S-501
S-501
S-404
S-404
8' - 11"38' - 0"19' - 5"14' - 4"8' - 7"20' - 2"2' - 9"
8' - 11"38' - 0"33' - 9"28' - 9"
EOD
6"
S-404
S-404
S-404
S-404
S-404
S-404
S-404
S-404
6 EQUAL SPACES 7 EQUAL SPACES
6 EQUAL SPACES 7 EQUAL SPACES
6 EQUAL SPACES 7 EQUAL SPACES
4 EQUAL SPACES 4 EQUAL SPACES 4 EQUAL SPACES 7 EQUAL SPACES
T 20' - 1 15/16"
W18X40
T 19' - 5 1/2" T 19' - 5 1/2"
W18X65
T 20' - 5 1/4"
W
X
T
/1
W
X
T
/1
W
X
T
/1
T 20' - 1 15/16"
W18X35
T 19' - 5 1/2" T 19' - 5 1/2"
W21X44
T 20' - 5 1/4"
W
X
W
X
W
X
T 20' - 1 15/16"
W21X57
T 19' - 5 1/2" T 19' - 5 1/2"
W21X57
T 20' - 5 1/4"
T 20' - 1 15/16"
W21X57
T 19' - 5 1/2" T 19' - 5 1/2"
W21X57
T 20' - 5 1/4"
K
K
K
T 19' - 10 7/8"
W16X26
T 19' - 5 1/2" T 19' - 5 1/2"
W21X44
T 19' - 10 7/8"
W14X26
T 19' - 5 1/2" T 19' - 5 1/2"
W21X44
T 20' - 5 1/4"
W
X
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
W
X
T
/4
W
X
T
/4
W
X
T
/4
W
X
T
/4
W
X
T
/4
W
X
W
X
W
X
W
X
W
X
W
X
W
X
T
W
X
T
/1
W
X
T
/8
W
X
T
K
K
K
K
K
K
K
K
K
T 20' - 5 3/16"
W16X26
T 19' - 10 7/8"
T 20' - 5 3/16"
W14X26
T 19' - 10 7/8"
T 20' - 11 1/2"
W16X26
T 20' - 5 3/16"
T 20' - 11 1/2"
W14X26
T 20' - 5 3/16"
K
K
K
K
K
K
EOD
6"
E O
D
E O
D
E O
D
VB-3
VB-4
VB-5
EOD
5 3/8"
E O
D
S-405
S-405
SIM.
S-404
S-405
TYP. 5
LOCATIONS
T 20' - 5 1/4"
W18X65
W21X57
W21X57
W21X44
W21X44
W21X44
ROOF FRAMING PLAN NOTES:
1. METAL ROOF DECK SHALL BE 1.5B 20 GA. WIDE RIB METAL DECK, 3 SPANS MINIMUM, SEE TYPICAL
DETAILS FOR ATTACHMENT TO STRUCTURE.
2. INDICATES DECK SPAN DIRECTION.
3. LOW ROOF T/STL ELEVATION = VARIES
4. HIGH ROOF T/STL ELEVATION = VARIES
5. SEE GENERAL NOTES S0-01 FOR ADDITIONAL PROJECT REQUIREMENTS.
6. VB-X INDICATES VERTICAL BRACE LOCATION.
7. * COORDINATE THE SIZE AND LOCATION OF MECHANICAL OPENINGS WITH MECHANICAL CONTRACTOR.
8. INDICATES MOMENT CONNECTION REQUIRED, SEE 3/S-402.
9. INDICATES DRAG CONNECTION REQUIRED, SEE 4/S-502.
10. FOR SUPPORT OF ALL ROOF TOP EQUIPMENT SHOWN ON PLAN, PROVIDE A STEEL ANGLE FRAME
AROUND OPENINGS AND PERIMETERS, SEE 5/S402.
11. SEE MECHANICAL ROOF PLANS FOR EXHAUST FANS AND ALL OTHER ROOF TOP EQUIPMENT NOT
SHOWN ON PLAN.
12. GENERAL CONTRACTOR TO COORDINATE FINAL UNIT LOCATIONS, SIZES, AND WEIGHTS AND NOTIFY
STRUCTURAL ENGINEER IMMEDIATELY OF ANY DISCREPANCIES.
13. * - COORDINATE OPENING SIZE IN DECK WITH CONTRACTOR INSTALLING THROUGH DECK ITEM. SEE
DETAIL 5/S-402.
US Army Corps of Engineers ®
SHEET OF
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
DISCLAIMER OF
I hereby specify that the documents intended to be authenticated by my seal are limited to this sheet, and I hereby disclaim any responsibility for all other Drawings, Specifications, Estimates, Reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project or survey.
Copyright © 2018 Kuhlmann design Group, Inc.
All rights reserved.
MISSOURI ARCHITECTURAL CORPORATION
CERTIFICATE LIC. NO.: 000216
MISSOURI PROFESSIONAL ENGINEERING CORPORATION
CERTIFICATE LIC. NO.: 000255
MISSOURI PROFESSIONAL LAND SURVEY CORPORATION
CERTIFICATE LIC. NO.: 000078
S-204
100% SUBMITTAL
S T
L
O U
IS
D
IS
T
R
IC
T M
M J
J A
S
K D
G
A C
A
-1 -2
M
IS
S O
U R
I H
IG
H
W A
Y
S A
IN
T
C H
A R
L E
S M
IS
S
O U
R I
H
IG
H F
R A
M
IN
G P
L A
N
A R
E A
B
D E
P A
R T
M E
N T
O F
E N
E R
G Y
L
E G
A C
Y M
A N
A G
E M
E N
T
W E
L D
O N
S P
R
IN
G S
IT
E
I N
T E
R P
R E
T
IV
E C
E N
T E
R
-0
AREA
B
KEY PLAN - AREA 'B'
Plan
North TrueNorth
SCALE: 1/8" = 1'-0"
HIGH ROOF T/STEEL - AREA 'B'
DOWEL SIZE
MIN. EMBED IN
UNCRACKED
CONCRETE** (IN.)
#3 5.3 6 1/2" 3 1/2"
#4 9.6 9" 4 1/2"
#5 14.9 12" 6"
#6 21.1 14" 7"
#7 28.8 18" 8 1/2"
NOTE:
1. * UNLESS NOTED OTHERWISE
2. ** REQUIRES ENGINEER APPROVAL PRIOR TO INSTALLATION
3. HOLES DRILLED WITH HAMMER DRILL AND CARBIDE TIP.
4. INSTALL PER REQUIREMENTS OF ICC ESR-2322.
#8
#9
#10
37.9
22"
26"
32"
10"
11"
13"
PULL-TENSION
PROOF LOAD*
(KIP)
MIN. EMBED IN
CRACKED CONCRETE
(IN.)
BEAM SIZE
TOP BARS OTHER BARS
COMPRESSION LAP
SPLICE
#3 23" 17" 12"
#4 29" 23" 15"
#5 37" 29" 19"
#6 43" 34" 23"
#7 64" 49" 27"
NOTE:
1. THESE VALUES ARE BASED ON ACI318-14 FOR GRADE 60 UNCOATED REINFORCING.
2. ALL LAP SPLICES SHALL BE TYPE "B" TENSION SPICES UNO.
3. ALL TABULATED REBAR SHALL SATISFY THE FOLLOWING:
BEAMS AND COLUMNS: CONCRETE COVER ≥ db AND OC BAR SPACING ≥ 2db AND STIRRUPS OR TIES THROUGHOUT DEVELOPMENT LENGTH (ld NOT LESS THAN
THE CODE MINIMUM.
OTHER MEMBERS: CONCRETE COVER ≥ db AND OC BAR SPACING ≥ 3db.
WHERE THESE CONDITIONS ARE NOT MET, TABULATED VALUES SHALL BE MULTIPIED BY A
FACTOR OF 1.5.
5000 PSI
TENSION LAP SPLICE "B"
NORMAL WEIGHT CONCRETE
#8
#9
#10
#11
72"
82"
91"
102"
56"
63"
71"
78"
30"
34"
39"
43"
BAR GRADING BAR SIZE MIN BEND Ø*
#3 THRU #8 6 BAR Ø
ALL GRADES OF
REINF.
#9, #10, & #11 8 BAR Ø
#14 & #18 10 BAR Ø
NOTE:
1. ALL REINFORCEMENT SHALL BE BENT COLD.
2. FIELD BENDING IS NOT PERMITTED.
BAR SIZE MIN BEND Ø*
#3 THRU #5 4 BAR Ø
ALL OTHER BARS SEE TABLE 1
* MEASURED ON INSIDE OF BAR
* MEASURED ON INSIDE OF BAR
TABLE 1 - PRIMARY REINFORCEMENT
TABLE 2 - STIRRUPS AND TIE REINFORCEMENT
B E
N D
Ø
B A
R S
IZ
E
B A
R Ø
B E
N D
Ø
THAN 2 1/2" OR 2 1/2" MIN.
4 BAR Ø BUT NOT LESS
B E
N D
Ø
B A
R S
IZ
E
O R
M
IN
B
A R
Ø
B E
N D
Ø
135.00°
B A
R S
IZ
E
O R
" M
IN
BAR
Ø
COMPACTED GRANULAR FILL
T
1/4" FORMED RECESS, SEE
SPECS. FOR SEALANT REQUIRED
REINF., SEE
FOUNDATION PLAN
SHEET S-101 & S-102#4 x 3'-0" LONG @ 18" o.c., GREASE
ONE END
10 MIL. VAPOR BARRIER
S
U N
D A
T
IO
N P
L A
N
REINF., SEE
FOUNDATION PLAN
SHEET S-101 & S-102
COMPACTED GRANULAR FILL
T
10 MIL.VAPOR BARRIER
S
U N
D A
T
IO
N P
L A
N
SEALANT,
SEE SPECS.
COMPACTED GRANULAR FILL
T
1/8" WIDE SAW CUT
CONTROL JOINT AS SHOWN
ON PLANS, 12'-0" MAX.
SPACING
10 MIL.VAPOR BARRIER
REINF., SEE
FOUNDATION PLAN
SHEET S-101 & S-102
S
U N
D A
T
IO
N P
L A
N
P L
A N
S E
E
P L
A N
S E
E
COMPACTED GRANULAR FILL
10 MIL.VAPOR BARRIER
S
U N
D A
T
IO
N P
L A
N
S
U N
D A
T
IO
N P
L A
N
M A
X
S E
E P
L A
N
P L
A N
S E
E
P L
A N
S E
E
(1) - #4 CONT. CORNER BAR,
EXTEND 2'-0" BEYOND STEP
BUT NOT LESS THAN 6"
2x SLAB DEPRESSION
COMPACTED GRANULAR FILL
10 MIL.VAPOR BARRIER
S
U N
D A
T
IO
N P
L A
N
S
U N
D A
T
IO
N P
L A
N
GRADE,
SEE CIVIL
#5 BARS @ 12" o.c., CENTERED IN SLAB
WELL-COMPACTED
CRUSHED ROCK
S E
E C
IV
IL
V A
R
IE
S
M
IN
4000 PSI CONCRETE
SLAB-ON-GRADETROWEL FINISH ALL
OUTSIDE EDGES WITH
1" CHAMFER
#5 BAR CONT.6" 1' - 0"
HOOK END 12" MIN.
NOTE:
ALL BENT BARS SAME
SIZE AND SPACING
AS HORIZONTAL
STEEL
CORNER DETAIL
NOTE:
ALL BENT BARS SAME
SIZE AND SPACING
AS HORIZONTAL
STEEL
INTERSECTION DETAIL
NOTE:
ALL BENT BARS SAME
SIZE AND SPACING
AS HORIZONTAL
STEEL
CORNER DETAIL
NOTE:
ALL BENT BARS SAME
SIZE AND SPACING
AS HORIZONTAL
STEEL
INTERSECTION DETAIL
LAP - SEE 8/S-301
TOP BAR TENSION
L A
P
S E
E
/S -3
T O
P B
A R
T E
N S
IO
N
LAP - SEE 8/S-301
TOP BAR TENSION
L A
P
S E
E
/S -3
T O
P B
A R
T E
N S
IO
N
LAP - SEE 8/S-301
TOP BAR TENSION
L A
P
S E
E
/S -3
T O
P B
A R
T E
N S
IO
N
LAP - SEE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.